ML081230616

From kanterella
Jump to navigation Jump to search
Annual Radiological Environmental Operating Report
ML081230616
Person / Time
Site: Wolf Creek 
Issue date: 04/28/2008
From: Flannigan R
Wolf Creek
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA 08-0037
Download: ML081230616 (153)


Text

WeLF CREEK

'NUCLEAR OPERATING CORPORATION Richard D. Flannigan Manager Regulatory Affairs April 28, 2008 RA 08-0037 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-482: 2007 Annual Radiological Environmental Operating Report Gentlemen:

Enclosed is the Annual Radiological Environmental Operating Report, which is being submitted pursuant to Wolf Creek Generating Station (WCGS) Technical Specification 5.6.2. This report covers radiological environmental monitoring around WCGS for the period of January 1, 2007, through December 31, 2007.

No commitments are identified in this correspondence. If you have any questions concerning this matter, please contact me at (620) 364-4117, or Ms. Diane Hooper at (620) 364-4041.

Sincerely, Richard D. Flannigan RDF/rlt

Enclosure:

2007 Annual Radiological Environmental Operating Report cc:

E. E. Collins (NRC), w/e V. G. Gaddy (NRC), w/e B. K. Singal (NRC), w/e Senior Resident Inspector (NRC), w/e P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNVET

WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION 2007 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT Ak V

April 15, 2008

TABLE OF CONTENTS List of Tables ii List of Figures ii List of Charts ii Executive Summary 1

Introduction 1

I.

Program Description 1

I1. Discussion of Results 4

I1l. Program Revisions/Changes 9

IV. Program Deviations 9

V. Interlaboratory Comparison Program Results 10 VI. Comparison to the Radioactive Effluents Release Program 10 Tables 11 Figures 19 Charts 24 Appendix A - Interlaboratory Comparison Program Results A-1 Appendix B -* Summary Tables B-1 Appendix C - 2007 Individual Sample Results C-1 Air Particulate and Charcoal Filters C-1 Quarterly Air Particulate - Gamma C-13 Surface Water C-25 Ground Water C-33 Drinking Water C-48 Quarterly Drinking Water - Tritium C-56 Shoreline Sediment C-58 Fish C-62 Food/Garden C-67 Feed and Forage C-76 Bottom Sediment C-79 Aquatic Vegetation C-83 Terrestrial Vegetation C-85 Soil C-87 Appendix D - 2007 Land Use Census Report D-1

LIST OF TABLES 1 Radiological Environmental Monitoring Program Description 11 2

Sample Location Identifiers, Distances (Miles) and Directions (Sectors) 16 3

TLD Results 18 LIST OF FIGURES 1 Airborne Pathway Sampling Locations 19 2

Direct Radiation Pathway Sampling Locations 20 3 Waterborne Pathway Sampling Locations 21 4

Ingestion Pathway Sampling Locations 22 5

Distant Sampling Locations 23 LIST OF CHARTS 1 Airborne Gross Beta Weekly Results 24 2

Historical Airborne Smoothed Indicator and Control Gross Beta 25 3

TLD Nearsite Locations and Control Locations 26 4

Coffey County Lake Surface Water Tritium Data 27 5

Drinking Water Gross Beta (5 years) 28 6

Detected Co-60 Activity in Coffey County Lake Discharge Cove Bottom Sediment 29 7

Detected Cs-1 37 Activity in Bottom Sediment 30 ii

EXECUTIVE

SUMMARY

Plant-related activation, corrosion or fission products were not detected during 2007 in airborne particulate and radioiodine filters, ground water, drinking water, shoreline sediment, broadleaf vegetation, crops, terrestrial vegetation, aquatic vegetation, or soil samples.

Activation, corrosion or fission products attributable to plant operation were detected during 2007 in surface water, fish, and bottom sediment samples.

Nuclides detected in Radiological Environmental Monitoring Program (REMP) samples were below applicable NRC reporting levels.

Based upon the radiological environmental monitoring results, it was concluded that station operations had no significant radiological impact on the health and safety of the public or the environment.

INTRODUCTION The 2007 Annual Radiological Environmental Operating Report for Wolf Creek Generating Station (WCGS) covers the period from January 1 through December 31, 2007.

WCGS is located in Coffey County, Kansas, approximately five miles northeast of Burlington, Kansas.

Fuel loading commenced at WCGS on March 12, 1985. The operational phase of the REMP began with initial criticality on May 22, 1985, and the first detectable quantities of radioactivity were reported in plant effluents in June 1985.

This report contains a description of the REMP conducted by Wolf Creek Nuclear Operating Corporation (WCNOC), a discussion of monitoring program results, the revisions or changes to the program, program deviations, the Interlaboratory Comparison Program and a comparison to the Radioactive Effluents Release Program. The Interlaboratory Comparison Program results, a summary of results in the Nuclear Regulatory Commission (NRC) Branch Technical Position specified format, the individual sample results and the Land Use Census Report are included as appendices.

I. PROGRAM DESCRIPTION Radiological environmental samples were collected according to the schedule in WCGS procedure AP 07B-004, Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program). Environmental samples were collected by the WCGS Environmental Management group and were analyzed by Environmental, Inc.

Detroit Edison processed environmental thermoluminescent dosimeters (TLDs) at the Enrico Fermi 2 plant. Table 1 lists sampling pathways and frequencies of sampling and analysis.

Table 2 lists each sample location's distance and direction from the plant. Samples in addition to those required by the WCGS Offsite Dose Calculation Manual (ODCM) were also obtained and analyzed.

The following is a description of the sampling and analysis program by individual pathways.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Pagel of30

A. Airborne Pathway Low volume air sampling pumps collected particulate and radioiodine samples on 47 mm glass fiber filters and charcoal canisters, respectively.

The filters and charcoal canisters were changed out weekly, labeled, and shipped to Environmental, Inc. for analysis. During February of 2007, air samplers with digital flow meters were installed. These air sample units digitally display the total time, total volume and flow rate.

Gross beta analysis of the air particulate samples was performed after a nominal 72-hour period to allow the radon and thoron daughter products to decay.

Weekly air particulate filters were combined into quarterly composites for each location and analyzed for gamma emitting isotopes.

Charcoal canisters were routinely counted in groups of five to determine the presence or absence of 1-131. Positive indication of 1-131 would have resulted in analysis of each individual charcoal canister.

Air samples were collected from six locations. Indicator locations 2, 37 and 49 are located in the three sectors with the highest ground level deposition constants (D/Q).

Air sampling stations are also located in the community of New Strawn (indicator location 32) and a control location at Harris (location 48). Supplemental indicator location (location 18) was also sampled during the year. Distances and directions to sampling locations from the plant are listed in Table 2, indicator locations are shown in Figure 1, and the control location is shown in Figure 5.

B. Direct Radiation Pathway Panasonic UD-814 TLDs were used at 43 locations during the sample year. The TLDs consist of one lithium-borate element and three calcium sulfate elements in a plastic case.

TLDs were typically positioned roughly 3 to 4 feet above the ground in plastic thermostat boxes.

The thermostat boxes protect the TLDs from the elements and tampering. Two TLDs were placed at each designated location.

The TLDs were changed out quarterly. Indicator TLD sample locations are illustrated in Figure 2 and control locations are shown in Figure 5. Table 2 provides the distance and direction of each location from the plant. Control locations were 39 (Beto Junction) and 48 (Harris).

C. Waterborne Pathway All water samples were analyzed to determine whether gamma emitters were present.. In addition to gamma isotopic analysis, radiochemical analysis for 1-131 was performed.: on drinking water and ground water samples. Gross beta analysis was also performed on drinking water samples. Tritium analysis was performed monthly by liquid scintillation for surface water and quarterly for drinking water.

Tritium analysis was also performed on ground water samples. Water sampling locations are listed in Table 2 and are shown in Figures 3 and 5.

Monthly grab samples of surface water were collected from John Redmond Reservoir (JRR) as a control location and from the "SP" location, which is located near the spillway of Coffey County Lake, formally known as Wolf Creek Lake, as an indicator location.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 2 of 30

Quarterly grab samples of ground water were collected from seven wells.

Location B-12 is hydrologically up gradient from the site and was used as a control location. Six locations (C-10, C-49, F-i, G-2, J-1 and J-2) are hydrologically down gradient from the site and were used as indicator sample locations.

Drinking water was sampled at the water treatment facilities for the towns of Burlington (control location BW-1 5) and Iola (indicator location IO-DW). The Burlington facility is located upstream and the Iola facility is located downstream of the confluence of the discharge from Coffey County Lake and the Neosho River.

Composite samples were obtained monthly from automatic samplers at each location that collected approximately 27 ml of drinking water every two hours.

Shoreline sediments were sampled semiannually. Gamma isotopic analysis was performed on the shoreline sediment samples. Shoreline sediment sample locations were the Coffey County Lake discharge cove (DC) indicator location and at the control location (JRR).

D. Ingestion Pathway Because no sampling locations that produce milk for human consumption were identified within five miles of the plant, milk was not collected during the sample year.

Fish were sampled semiannually from the tail waters of JRR (control, Figure 4) and from Coffey County Lake (indicator, Figure 4). Gamma isotopic analysis was performed on the boneless meat portions of the fish.

Several species of game fish and rough fish were sampled. Fish were also analyzed for tritium.

Broadleaf vegetation samples were collected monthly when available during the growing season from four gardens. Three indicator (C-2, N-1 and Q-6) gardens (Figure 4) and one control (D-2) garden (Figure 5) were sampled. Gamma isotopic analyses were performed on all samples.

Crop samples were obtained from two indicator locations (NR-D1 and NR-D2) downstream of the confluence of Wolf Creek and the Neosho River. Two crop samples were obtained from control location NR-UI.

Gamma isotopic analysis was performed on each sample.

Crop sample locations are identified on Figure 5.

E. Additional Samples Collected (not required by ODCM)

Quarterly, duplicate ground water grab samples were obtained from indicator location C-49 and were labeled L-49. These duplicate samples served as laboratory quality checks. The ground water samples were analyzed for gamma emitters, 1-131 and tritium.

Shoreline sediments were collected at the Black Bear Bosin area (BBB) and the SC (Stringtown Cemetery).

Gamma isotopic analysis was performed on the shoreline sediment samples.

These indicator samples were collected as part of a cooperative sampling effort with the Kansas Department of Health and Environment (KDHE). The sample locations are identified on Figure.3.

Bottom sediment samples were collected at the Environmental Education Area (EEA) and from the Make-Up Discharge Structure (MUDS).

Gamma isotopic analysis was performed on the 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 3 of 30

bottom sediment samples. These indicator samples were collected as part of a cooperative sampling effort with the Kansas Department of Health and Environment (KDHE). The sample locations are identified on Figure 3.

Bottom sediment samples were collected semiannually at the Coffey County Lake discharge cove (DC) indicator location and the control location (JRR).

Gamma isotopic analysis was performed on the bottom sediment samples.

These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 3.

Aquatic vegetation was collected from indicator locations EEA and SC.

Gamma isotopic analysis was performed on the aquatic vegetation samples. These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 3.

Terrestrial vegetation was sampled from indicator locations EEA and MUDS. Gamma isotopic analysis was performed on the terrestrial vegetation sample. These samples were collected as part of a cooperative sampling effort with the KDHE.

The sample locations are identified on Figure 4.

Soil was sampled from indicator locations MUDS and EEA.

Gamma isotopic analysis was performed on the soil samples.

These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 4.

Distance and direction information for the sampling locations listed in this section are outlined in Table 2.

II. DISCUSSION OF RESULTS Analysis results for all pathways are summarized in Appendix B using the format described in Radiological Assessment Branch Technical Position, Revision 1, November 1979 (NRC Generic Letter 79-065). Results for individual samples are listed in Appendix C.

In this section, results are discussed by pathway and analysis type.

Monitoring results,are compared with control data, preoperational values, sources of radioactivity, and effluent releases when applicable. Trends or seasonal effects are discussed.

A. Airborne Pathway Chart 1 graphically illustrates weekly gross beta results for the sample year. Chart 2 represents the historical smoothed averages of indicator and control gross beta data.

Charts 1 and 2 demonstrate how closely the indicator and control locations tracked together.

Chart 2 reveals a seasonal cyclic trend in which gross beta values peak in the winter months (December or January) and decrease to a low point in the spring months (May or June). This trend is expected and is attributed to seasonal meteorological changes, i.e., changes in prevailing winds and precipitation.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 4 of 30

The gross beta results of 2007 were compared to pre-operational monitoring results of 1983 and 1984.

The weekly gross beta analyses range for' 1983 and 1984 was 0.0064 to 0.084 pCi/m 3. The 2007 weekly gross beta analyses range for indicator locations was 0.010 to 0.062 pCi/m 3, which was within the 1983 and 1984 pre-operational range. Additionally, the annual mean for indicator locations for 2007 (0.030 pCi/m 3) was lower than the annual mean for 1983 (0.032 pCi/m 3).

The gross beta results for the indicator locations were also compared to the control location.

The annual mean for indicator locations for 2007 (0.030 pCi/m 3) was similar to the annual mean of the control location (0.029 pCi/m 3).

Naturally occurring Be-7 activity was detected, as was the case during pre-operational monitoring.

In 1984, the range for Be-7 detected activity was 0.024 to 0.211 pCi/m 3 for indicator locations, and the annual mean for indicator locations Was 0.069 pCi/m 3. In 2007, the range for Be-7 detected activity was 0.060 to 0.114 pCi/m 3 for indicator locations, and the annual mean for indicator locations was 0.091 pCi/m 3.

The control location annual mean for Be-7 detected activity (0.087 pCi/m 3) was similar to the indicator locations annual mean (0.091 pCi/m 3).

1-131 activity was not detected in the weekly analysis of charcoal filters at any location.

No effects of plant operation were seen via the airborne pathway for the year, and no unusual trends were noted.

B. Direct Radiation Pathway Quarterly gamma exposures measured at each location are shown in Table 3.

Measured values have been converted to a standard 90-day quarter.

The annual mean of all indicator locations in 2007 was 0.212 mR/day and the annual mean for the control locations was 0.210 mR/day. For pre-operational comparison, in 1981, the annual mean of all indicator locations was 0.21 mR/day and annual mean for the control locations was 0.19 mR/day.

Results from TLDs located near the plant (less than three miles), which would be most affected by changes in plant operation, were combined into quarterly averages.

These nearsite averages, using locations 1, 2, 7-9, 11-14, 18, 26, 27, 29, 30, 37 and 38 are compared to control location results (locations 39 and 48) in Chart 3. Chart 3 also includes preoperational data for comparison.

The nearsite TLD locations have historically trended higher than the control locations both prior to and after WCGS became operational.

C. Waterborne Pathway (1) Surface Water Tritium, attributable to WCGS operation, was detected in all surface water samples collected from Coffey County Lake during 2007. Chart 4 illustrates the yearly averages of surface water tritium data for the spillway location. Chart 4 shows that the average tritium concentration of 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 5 of 30

the lake may have reached equilibrium since the last four years indicate a slightly downward trend.

ODCM required lower limits of detection were met and tritium activity was not detected in samples obtained from the control location (JRR).

During pre-operational environmental radiological monitoring, measured radiological activity was not detected in surface water samples.

Tritium was the only activity detected in surface water samples and no unusual trends were noted.

(2) Ground Water ODCM required lower limits of detection were met and radioactivity was not detected in any ground water samples.

(3) Drinking Water Chart 5 illustrates the drinking water gross beta results for the last five years and how closely the gross beta results compared for the indicator and control locations.

Gross beta activity was detected in all drinking water samples. The annual mean of the control location gross beta activity (3.0 pCi/L) was similar when compared to the annual mean of the indicator location (3.2 pCi/L). The 2007 annual means of gross beta activity for both the control and indicator locations were lower than those of the pre-operational monitoring year of 1984. In 1984, the annual mean of the control location gross beta activity was 6.4 pCi/L, and the annual mean of the indicator location gross beta activity was 7.5 pCi/L.

ODCM required lower limits of detection were met.

Additionally, radionuclides were not detected by the 1-131 or gamma isotopic analyses.

Activity due to plant operation was not evident in drinking water samples during 2007 and no unusual trends were noted.

(4) Shoreline Sediment Naturally occurring K-40 was detected in samples obtained from the indicator location (DC) and in samples obtained from the control location (JRR).

K-40 was also detected during pre-operational shoreline sediment monitoring.

Cs-137 activity was also detected in one shoreline sediment sample obtained from the control location (JRR).

ODCM required lower limits of detection were met. Activity due to plant operation was not evident in shoreline sediment samples during 2007 and no unusual trends were noted.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 6 of 30

D. Ingestion Pathway (1) Milk Milk was not collected during the sample year since no indicator locations within five miles of the plant were identified during the Land Use Census.

(2) Fish Naturally occurring K-40 activity was detected in all fish samples.

K-40 activity was also detected during pre-operational fish monitoring.

During 2007, fish were also analyzed for tritium. All fish samples taken from Coffey County Lake had tritium activity detected (6,475 pCi/kg annual mean). The detected tritium activity was attributable to plant operation.

An adult consuming 21 kilograms of fish, at the maximum measured tritium concentration for 2007 (7,266 pCi/kg), would receive a committed effective dose equivalent of 0.010 mRem.

Tritium activity was not detected in the control samples collected from JRR.

No other radionuclides were detected in fish during the year. The ODCM required lower limits of detection were met and no unusual trends were noted.

(3) Broadleaf Vegetation Gamma analyses of broadleaf vegetation samples obtained from indicator and control locations detected naturally occurring gamma emitters Be-7 and K-40. Be-7 and K-40 activity were also detected pre-operationally.

The ODCM required lower limits of detection were met and no unusual trends were noted.

Activity attributable to plant operation was not detected.

(4) Crop Samples Gamma analysis detected naturally occurring K-40 to be present in all of the samples. K-40 activity was also detected during pre-operational crop monitoring.

K-40 was the only activity detected in crop samples.

The ODCM required lower limits of detection were met and no unusual trends were noted.

E. Additional Samples Collected (not required by ODCM)

(1) Bottom Sediment Naturally occurring K-40 was detected in all of the bottom sediment samples. K-40 activity was also detected during pre-operational bottom sediment monitoring.

Co-60 activity (107.9 and 88.7 pCi/kg) was detected in the indicator samples obtained from the Coffey County Lake discharge cove. Co-60 activity was attributable to plant operation and has been identified in plant effluents.

Co-60 activity was not detected in pre-operational environmental monitoring and was not detected in samples collected from control location JRR 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 7 of 30

during 2007. Chart 6 plots the Co-60 detected activity from the discharge cove and reflects a decreasing trend. This downward trend is due to improvements made in the process system.

Cs-137 activity (179.8 and 167.7 pCi/kg) was detected in the indicator samples obtained from the Coffey County Lake discharge cove. A portion of this activity is due to fallout and a portion of this activity is likely plant-related since Cs-1 34 activity has been detected in the past. Cs-1 37 activity was detected in pre-operational samples, and the. results for 2007 indicator bottom sediment samples were within the pre-operational range. (Cs-137 activity detected in 1981 and 1982 was in the range of 79 to 953 pCi/kg.

The decay corrected range of pre-operational Cs-137 activity detected is approximately 44 to 525 pCi/kg.) Cs-137 activity has been identified in plant effluents. Cs-137 activity (121.5 and 129.3 pCi/kg) was also detected in the control location (JRR) bottom sediment samples.

Chart 7 plots the Cs-137 detected activity from the discharge cove indicator location and JRR control location bottom sediment samples. The detected Cs-137 activity measured from the discharge cove location reflects a decreasing trend. The Chart 7 trend line indicates that as expected, Cs-137 activity detected at the JRR control location has been decreasing.

No other radionuclides were detected in bottom sediment samples and no unusual trends were noted.

(2) Aquatic Vegetation Naturally occurring Be-7 and K-40 activity were detected in samples collected in 2007. Be-7 and K-40 activity were also detected during pre-operational monitoring.

No other radionuclides were detected in aquatic vegetation samples and no unusual trends were noted.

(3) Terrestrial Vegetation Naturally occurring Be-7 and K-40 activity were detected in samples collected in 2007.

No other radionuclides were detected. No unusual trends were identified.

(4) Soil Naturally occurring K-40 activity was detected in both of the soil samples. K-40 activity was also detected during pre-operational soil monitoring.

Cs-137 activity (326.4 and 446.2 pCi/kg) was also detected in both of the soil samples. This activity is likely due to fallout. Data was reviewed for soil samples collected pre-operationally.

The Cs-137 range from February of 1985 was 255 to 2,160 pCi/kg, dry. The decay corrected range of pre-operational Cs-137 activity detected in soil is approximately 153 to 1,296 pCi/kg.

The detected Cs-137 is well within the pre-operational decay corrected range.

No unusual trends were identified.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 8 of 30

III. PROGRAM REVISIONS/CHANGES Based upon results from the corrective action program, the following TLD locations were added to the program during January 2007: 46, 44, 50, 51 and 52. The following TLD locations were removed from the program:

3, 10, 6, 21, 28, 31 and 33. These changes were made to enhance the effectiveness of the program.

On February 21, 2007, air sample pumps with digital flow meters were installed. Change was made to enhance air sample volume data that is used to calculate concentration.

IV. PROGRAM DEVIATIONS Air Samples The air sample locations listed below failed to meet the requirement for "continuous sampler operation." As described in footnote (1) of procedure AP 07B-004, Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program), Table 5-1, deviations are permitted from the required sampling schedule due to malfunction of sampling equipment and other legitimate reasons. Discrepancies greater than five percent between Total Military Time and Total Digital Flow Meter Time, which resulted in a loss of air sample collected, are listed in the following table.

Location Sample Period Percent Explanation of Deviation/

Discrepancy/

Condition Report (CR) Number/

Hours Comments Unavailable 48 02/28/07 - 03/07/07 96%/-161 Equipment Malfunction/

CR 2007-000939/

Due to small sample volume, the LLD for 1-131 was not obtained.

48 03/07/07- 03/14/07

>77%/-127 Equipment Malfunction/

CR 2007-000939 48 07/11/07 - 07/18/07 58%/-95 Equipment Malfunction/

CR 2007-002833 48 08/01/07 - 08/07/07 Unknown Equipment Malfunction/

CR 2007-002833/

Due to small sample volume, the LLDs for gross beta and 1-131 were not obtained.

Ground Water Samples During the first quarter of 2007, ground water was not sampled from location G-2.

The landowner's water pump was out of service during this time.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 9 of 30

V. INTERLABORATORY COMPARISON PROGRAM RESULTS During 2007, Environmental, Inc., Midwest Laboratory was contracted to perform radiological analysis of environmental samples for WCNOC. The lab participated in the intercomparison studies administered by Environmental Resources Associates.

Appendix A is the Interlaboratory Comparison Program Results for Environmental, Inc., Midwest Laboratory.

Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also contained in Appendix A.

VI. COMPARISON TO THE RADIOACTIVE EFFLUENTS RELEASE PROGRAM As described in the section discussing radioisotopes found in fish from Coffey County Lake, dose that may be received as a result of tritium released from WCGS is comparable with the theoretical doses calculated by the Radioactive Effluent Release Program.

The theoretical doses calculated by the Radioactive Effluent Release Program assume that a person drinks the water from Coffey County Lake and eats the fish from Coffey County Lake.

Based upon these assumptions the dose to man from both pathways was calculated to be 0.110 mRem for 2007.

Using sample data obtained from the REMP, an adult drinking 2 liters per day of surface water from Coffey County Lake, using the average tritium activity (10,442 pCi/L), would receive a committed effective dose equivalent of 0.477 mRem per year. For an adult eating 21 kg of fish per year from Coffey County Lake, using the average tritium activity (6,475 pCi/kg), would receive a committed effective dose equivalent of 0.009 mRem per year. Based upon the REMP results, the dose from both pathways was calculated to be 0.486 mRem per year.

It should be noted that the Coffey County Lake is not a drinking water source. Calculating the dose to man for tritium detected in the Coffey County Lake surface water is for comparison purposes only.

The tritium dose values are being compared on a qualitative basis. It is not expected that the annual doses, as calculated in the Radioactive Effluent Release Report, would compare directly to those calculated from the REMP. The Radioactive Effluent Release Report provides a 'snap shot' of potential dose resulting from the year's releases.

The REMP data indicates the accumulated result of releasing tritium into the lake since the start of plant operation.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 10 of 30

TABLE 1 2007 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM DESCRIPTION (SAMPLE COLLECTION SPECIFIED BY ODCM)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS (See Figures 1 & 5)

SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS AIRBORNE Radioiodine and Particulates Samples from six locations Continuous sampler operation with sample collection weekly, or more frequently if required, by dust loading.

Samples from locations near the site boundary in three sectors having the highest calculated annual average D/Q (Locations 2, 37, 49 and supplemental location 18 on Figure 1)

Analyze radioiodine canister weekly for 1-131 Analyze particulate filter weekly for gross beta activity; perform quarterly gamma isotopic analysis composite (by location)

Sample from the vicinity of a community having the highest calculated annual average D/Q (Location 32 on Figure 1, New Strawn)

Sample from a control location 9.5 to 18.5 miles distant in a low ranked D/Q sector (Location 48 on Figure 5) 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 11 of 30

TABLE 1 (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE DIRECT RADIATION NUMBER OF SAMPLES AND SAMPLE LOCATIONS (See Figures 2 & 5) 40 routine monitoring stations with two or more dosimeters measuring dose continuously, placed as follows:

SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS Quarterly Gamma dose quarterly An inner ring of stations, one in each meteorological sector 0-3 mile range from the site (Locations 1, 7, 9, 11-13, 18, 26, 27, 29, 30, 37, 38, 46, 47 & 49 on Figure 2).

An outer ring of stations, one in each meteorological sector in the 3 to 5 mile range from the site (Locations 4, 5, 15-17, 19, 22-25, 32, 34-36, 50 & 51 on Figure 2). Four sectors

[A, B, G & J] contain an additional station (Locations 2, 8, 14 &

20).

The balance of the stations to be placed in special interest areas such as population centers (Locations 23, 32 & 52), nearby residences 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 12 of 30

TABLE 1 (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS DIRECT RADIATION (cont.)(

r C

E W/

c r

C z

WATERBORNE(

many locations are iear a residence),

schools (Locations 23

, 52), Environmental Education Area (44),

'CL Public Fishing

,rea (46) and in two areas to serve as

ontrol stations 10-20 niles distant from the site (Locations 39 and 18 on Figure 5).

See Figure 3)

Surface Ground One sample upstream (Location JRR on Figure 3) and one sample downstream (Location SP on Figure 3).

Samples from one or two sources only if likely to be affected.

Monthly grab sample Quarterly grab sample Monthly gamma isotopic analysis and composite for tritium analysis quarterly Quarterly gamma isotopic and tritium analysis Indicator samples at locations hydrologically down gradient of the site (Locations C-10, C-49, F-I, G-2, J-1 and J-2 on Figure 3);

control sample at a location hydrologically up gradient of the site (Location B-12 on Figure 3).

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 13 of 30

TABLE I (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS WATERBORNE (cont.)

Drinking Shoreline Sediment Sample of municipal water supply at an indicator location downstream of the site (Location 10-DW on Figure 5); control sample from location upstream of the site (Location BW-15 on Figure 3).

One sample from the vicinity of Coffey County Lake discharge cove (Location DC on Figure 3); control sample from John Redmond Reservoir (Location JRR on Figure 3).

(See Figures 4 & 5)

Samples from milking animals at three indicator locations within 5 miles of the site having the highest dose potential (currently there are no locations producing milk for human consumption within 5 miles of the site); one sample from a control location greater than 10 miles from the site if indicator locations are sampled.

Monthly Composite Semiannually Monthly gamma isotopic analysis and gross beta analysis of composite sample. Quarterly tritium analysis of composites.

Semiannual gamma isotopic analysis INGESTION Milk Semimonthly April to November; monthly December-March Gamma isotopic analysis and 1-131 analysis of each sample 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 14 of 30

TABLE 1 (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS INGESTION (cont.)

Fish Broadleaf Vegetation Irrigated Crops Indicator samples of 1 to 3 recreationally important species from Coffey County Lake; control samples of similar species from John Redmond Reservoir spillway (Figure 4).

Samples of available broadleaf vegetation from two indicator locations (using the criteria from the "Land Use Census" section) with highest calculated annual average D/Q (Locations Q-6 and N-1 and alternate location C-2 on Figure 4);

sample of similar broadleaf vegetation from a control location 9.5 to 18.5 miles distant in a low ranked D/Q sector (Location D-1 or alternate location D-2 on Figure 5).

Sample of crops irrigated with water from the Neosho River downstream of the Neosho River - Wolf Creek confluence (Location NR-D1 and NR-D2 on Figure 5).

Semiannually Gamma isotopic analysis on edible portions Monthly when available At time of harvest Gamma isotopic analysis on edible portions Gamma isotopic analysis on edible portions 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 15 of 30

TABLE 2 SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)

Sample Type Location Distance from Direction Sector Identifier Reactor Air Particulates and Radioiodine 2

2.7 N

A 18 3.0 SSE H

32 3.1 WNW P

37 2.0 NNW R

48 14.7 ENE D

49 0.8 NNE B

Dosimeters 1

1.4 N

A 2

2.7 N

A 4

4.1 NNE B

5 4.1 NE C

7 2.1 NE C

8 1.7 NNE B

9 2.0 ENE D

11 1.7 E

E 12 1.9 ESE F

13 1.6 SE G

14 2.5 SE G

15 4.6 ESE F

16 4.3 E

E 17 3.7 SE G

18 3.0 SSE H

19 3.9 SSE H

20 3.3 S

J 22 3.9 SSW K

23 4.3 Sw L

24 4.1 WSW M

25 3.4 W

N 26 2.4 WSW M

27 2.2 SW L

29 2.7 SSW K

30 2.5 W

N 32 3.1 WNW P

34 4.4 NW Q

35 4.6 NNW R

36 4.2 N

A 37 2.0 NNW R

38 1.2 NW Q

39 13.1 N

A 41 0.8 NNW R

42 0.8 SSE H

43 0.7 WNW P

44 3.0 NNW R

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 16 of 30

TABLE 2 (Cont.)

SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)

Sample Type Location Distance from Direction Sector Identifier Reactor Dosimeters 46 1.6 WNW P

47 0.16 S

J 48 14.7 ENE D

49 0.8 NNE B

50 3.6 ENE D

51 4.0 S

J 52 3.6 SW L

Surface Water JRR 3.7 W

N SP 3.2 SSE H

Ground Water B-12 1.9 NNE B

C-10 2.7 W

N C-49/L-49 2.8 SW L

F-1 2.5 ESE F

G-2 3.6 SE G

J-1 3.8 S

J J-2 4.3 S

J Drinking Water BW-15 3.9 SW L

1O-DW 26.1 SSE H

Shoreline Sediment BBB 2.4 NW Q

DC 0.8 WNW P

JRR 3.6 W

N SC 0.8 NNW R

Fish CCL 0.6 WNW P

JRR 3.7 W

N Food/Garden C-2 1.9 NE C

D-2 14.8 ENE D

N-1 2.4 W

N Q-6 2.4 NW Q

Crops NR-D1 8.9 S

J NR-D2 11.5 S

J NR-U1 4.0 SSW K

Bottom Sediment DC 0.9 WNW P

EEA 3.0 NNW R

JRR 3.7 W

N MUDS 1.5 WNW P

Aquatic Vegetation EEA 3.0 NNW R

SC 0.8 NNW R

Terrestrial Vegetation EEA 3.0 NNW R

MUDS 1.5 WNW P

Soil EEA 3.0 NNW R

MUDS 1.5 WNW P

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 17 of 30

TABLE 3 TLD Results (mR/S0-day qtr.)

Location Qtr. 1 Qtr. 1 2-Qtr. 2 Qtr. 2 2-Qtr. 3 Qtr. 3 2-Qtr. 4 Qtr. 4 2-Total 90-Day std.

90-Day std.

90-Day std.

90-Day std.

Annual Avg.

dev.

Avg.

dev.

Avg.

dev.

Avg.

dev.

Exposure S_(

mR) 1 19.9 1.5 20.4 0.9 21.4 5.1 19.6 1.5 81.3 2

19.5 3.4 17.8 0.6 17.9 1.1 17.1 0.9 72.3 4

21.3 3.5 19.3 1.0 20.1 1.5 18.5 1.0 792 5

20.1 4.4 17.5 1.4 18.6 1.0 17.2 1.1 73.3 7

19.6 2.0 19.4 2.4 18.4 1.1 18.1 1.0 75.5 8

20.2 1.8 20.6 3.1 20.9 1.2 19.1 2.7 80.8 9

18.0 0.8 18.2 2.2 17.8 2.0 16.8 0.6 70.8 11 22.4 3.4 20.5 1.6 20.1 1.5 19.4 0.7 82.4 12 20.9 3.5 21.2 3.3 20.9 1.6 18.4 1.0 81.3 13 21.0 3.6 20.5 1.5 21.4 4.2 19.2 1.6 82.1 14 21.2 1.5 20.3 1.1 20.8 1.8 18.4 1.7 80.7 15 20.0 2.0 20.3 1.8 19.4 1.3 18.7 1.2 78.4 16 19.8 1.9 19.2 1.8 18.8 1.8 17.8 1.2 75.6 17 20.7 3.1 19.5 0.4 20.3 2.5 17.2 1.0 77.8 18 19.4 1.0 19.5 1.0 18.4 0.3 17.5 0.4 74.9 19 19.9 0.9 21.5 1.3 19.2 0.7 18.5 1.5 79.1 20 19.6 3.4 21.0 1.5 18.3 1.4 18.6 2.8 77.5 22 22.3 3.9 21.6 0.8 20.2 0.9 19.8 3.0 84.0 23 19.2 1.1 22.3 2.0 18.0 0.5 17.7 1.3 77.2 24 19.4 1.9 20.0 0.8 18.6 1.4 18.2 1.5 76.2 25 18.6 4.0 17.9 0.8 17.2 1.6 161 1.0 69.7 26 18.0 1.2 20.4 3.2 19.1 4.5 16.8 0.9 74.3 27 19.3 0.4 21.2 1.0 19.7 1.6 18.5 1.1 78.7 29 16.8 0.9 17.0 0.3 16.4 3.2 15.3 1.3 65.5 30 19.5 0.5 19.9 0.7 190 1.4 19.5 2.5 78.0 32 17.9 1.7 18.7 0.9 20.2 1.2 17.5 3.2 74,3 34 21.2 2.9 20.6 1.3 18.9 1.0 18.2 1.1 78.9 35 20.2 1.8 20.6 1.0 19.8 3.0 18.0 1.2 78.7 36 20.2 2.3 19.9 1.3 19.2 3.5 18.9 1.7 78.1 37 18.2 1.1 18.9 1.2 18.0 0.8 17.6 2.1 72.8 38 20.4 1.1 22.0 2.4 23.4 0.9 19.2 1.0 85.0 39 18.0 1.4 20.6 1.3 17.3 0.9 17.9 2.1 73.8 41 21.3 1.9 20.4 0.8 20.1 4.0 19.3 1.8 81,1 42 14.5 1.2 15.9 1.4 13.0 1.3 13.5 1.1 56.9 43 13.8 0.7 16.6 1.5 12.5 0.4 12.7 1.0 55.6 44 19.1 1.2 20.8 1.3 18.0 1.2 17.9 0.4 75.8 46 18.8 1.8 20.1 1.7 19.4 1.6 17.6 0.7 75.8 47 19.3 1.4 20.0 1.9 18.2 3.0 17.6 2.4 75.1 48 20.0 1.9 21.7 1.7 17.8 1.6 17.8 1.3 77.3 49 18.9 1.6 19.9 2.1 17.6 1.9 19.8 1.7 76.3 50 20.6 1.4 25.0 4.7 19.2 1.0 19.2 1.4 84,0 51 18.6 1.0 21.6 4.0 19.3 2.0 18.7 2.3 78.1 52 19.7 1.1 22.0 1.1 20.5 1.1 18.7 1.2 80

,8 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 18 of 30

FIGURE 1 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 19 of 30

FIGURE 2 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 20 of 30

FIGURE 3 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 21 of 30

FIGURE 4 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 22 of 30

FIGURE 5 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 23 of 30

CHART 1 2007 Airborne Gross Beta Weekly Results a) a)E a)

(n 0

(D 0.070 0.060 0.050 0.040 0.030 0.020 0.010 0.000 0

4 8

12 16 20 24 28 Week Number 32 36 40 44 48 52 s

Location 2

  • Location 18

+ Location 32 L Location 37

-,- Location 48 (Control)

  • Location 49

.2007 Annual Radi0logical Environmental Operating Report - Wolf Creek Generating Station Page 24 of 30

CHART 2 Historical Airborne Smoothed (Avg of 20) Indicator and Control Gross Beta a)

E 0

C.)

B

-0 0

0.

E U) 0 a1) 0.060 0.050-0.040-0.030-0.020 0.010N

,\\O Z

\\1

- - - Smoothed Avg. Indicator Locations Smoothed Avg. Control Location (40)

Smoothed Avg. Control Location (48) 2007 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 25 of 30

CHART 3 TLD Nearsite Locations and Control Locations 32.0 30.0 28.0 26.0 24.0 E 22.0 20.0 18.0 16.0 14.0 12.0 A-1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 e

Avg. of Nearsite Locations A

-Moving Avg. of Nearsite Locations (2 period) - - -

Avg. of Control Locations Moving Avg. of Control Locations (2 period) 2007 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 26 of 30

CHART 4 Coffey County Lake Surface Water Tritium Data 16000 14000 12000 10000 8000 6000 4000 2000

°j CI 0 4-1987 1989 1991 1993 1995 1997 1999 2001 2003


Yearly Average of Spillway Location -Polynomial Trendline 2005 2007 2007 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 27 of 30

CHART 5 Drinking Water Gross Beta (5 years)

CI 09co

(.3 9

8 7

6 5

4 3

2 1

0 0 0IN0000 N

0 0

N00

,0.

0"~~r ro OvO 0'O o

~

O",' b¢

~k

  • b O

O*

O"

  • b'*

O*

O*

',Z z,

")

BW15 (Control)

LW40 (Indicator)

- - - NFDW (Indicator)

-IODW (Indicator) 2007 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 28 of 30

CHART 6 Detected Co-60 Activity in Coffey County Lake Discharge Cove Bottom Sediment 2500 2000 CL 0.

1500 1000 500 0

I*-

co 0'

0 N

Co

'T Lto (o

r-Co 0'

00

-E Cq o

It O

(D I.

O co c0

0)
0)
0)
0) 0M
0)
0)
0)
0)
0) 0 0

0 0

0 0

0 0

0M M

0)
0)
0)
0)
0)
0)
0)
0)
0)
0)

M) 0 0

0 0

0 0

0 0

N N

N N

N N

N N

N 0

N N

N N

N N

N 0N N

N N

N N

N N

N N

(0 (0

(0 (0

(0 (0o0

(

(0 (0

(0 (0

(0 (0

(

(0 (D

(0 (D

(0 (0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 I --*-- Co-60 -Polynomial Trendline I 2007 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 29 of 30

CHART 7 Detected Cs-137 Activity in Bottom Sediment 1000 900 800 700 600 500 CL) 400 300 200 100 n

oL O

0 N

o C

0 N

N o

o o

Mo o-N 0*

N*

N0 N*

ND I 0 L 0 C*

i N

0 T--

0*

0-0 --

  • 0 0*-

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0-0 0

0 DC Cs-137 m

JRR Cs-137 -

Polynomial Trendline (DC)

Polynomial Trendline (JRR) 2007 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station

  • Page 30 of 30

-Environmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 Landiweh Road Nortbrook, IL 60062-2310 ph. (847) 564-0700 - fax (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:

Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year-, the complete Appendix is included in March, June, September and December monthly progress reports only.

January through December, 2007

Appendix A Interlaboratory Comparison Progqram Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

The results in Table A-2 list results for thermoluminescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.

Table A-3 lists results of the analyses on in-house "spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house 'blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve month, Acceptance is based on the difference of the results being less than the sum of the errors.

Complete analytical data for duplicate analyses is available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.

Results in Table A-7 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).

Attachment A lists acceptance criteria for "spiked" samples.

Out-of-limit results are explained directly below the result.

Al

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa One standard deviation Analysis Level for single determination Gamma Emitters 5 to 100 pCi/liter or kg 5.0 pCi/liter

> 100 pCi/liter or kg 5% of known value Strontium-89b 5 to 50 pCi/liter or kg 5.0 pCi/liter

> 50 pCi/liter or kg 10% of known value Strontium-90b 2 to 30 pCi/liter or kg 5.0 pCi/liter

> 30 pCi/liter or kg 10% of known value Potassium-40 a 0.1 g/liter or kg 5% of known value Gross alpha 5 20 pCi/liter 5.0 pCi/liter

> 20 pCi/liter 25% of known value Gross beta.

5 100 pCi/liter 5.0 pCi/liter

> 100 pCi/liter 5% of known value Tritium 5 4,000 pCi/liter

10 =

169.85 x (known)°'°9 33

> 4,000 pCi/liter 10% of known value Radium-226,-228

> 0.1 pCi/liter 15% of known value Plutonium

  • 0.1 pCi/liter, gram, or sample 10% of known value Iodine-1 31, 55 pCi/liter 6.0 pCi/liter Iodine-129b

> 55 pCi/liter 10% of known value Uranium-238,

5 35 pCi/liter 6.0 pCi/liter Nickel-63b

> 35 pCi/liter 15% of known value Technetium-99b Iron-55b 50 to 100 pCi/liter 10 pCi/liter

> 100 pCi/liter 10% of known value Othersb 20% of known value a From EPA publication, "Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004.

b Laboratory limit.

A2

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCi/L)

Lab Code Date Analysis Laboratory ERA Control Resultb Resultc Limits Acceptance STW-1 121 STW-1121 STW-1 122 STW-1122 STW-1 122 STW-1 122 STW-1 122 STW-1 123 STW-1123 STW-1 124 STW-1125 STW-1 125 STW-1 125 STW-1 125 STW-1 127 STW-1 127 STW-1 128 STW-1128 S-rW-1 128 STW-1 128 STW-1 128 STW-1 129 STW-1129 STW-1 130 STW-1 130 STW-1 130 STW-1 131 STW-1 131 STW-1 132 S1IW-1 132 STW-1 132 STW-1 132 STW-1132 STW-1 133 STW-1 133 STW-1 134 STW-1 135 STW-1 135 STW-1 135 STW-1 135 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 04/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 07/09/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 10/05/07 Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 H-3 Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-i 33 Co-60 Cs-1 34 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 H-3 Ra-226 Ra-228 Uranium 30.7 +/- 4.3 39.3 +/- 1.8 30.0 +/- 2.4 118.5 +/- 3.9 52.6 +/- 2.3 49.5 +/- 3.8 91.7 +/- 6.3 33.8 +/- 3.5 24.2 +/- 2.3 19.2 +/- 1.2 7540.0 +/- 255.0 13.0 +/- 0.6 19.9 +/- 2.7 4.5 +/- 0.2 51.7 +/- 5.0 21.4 +/- 2.3 19.4 2.2 32.8 +/- 2.0 67.0 +/- 2.9 61.6 +/- 3.8 55.6 +/- 7.5 19.2 +/- 1.6 9.1 +/-0.9 7.0 +/- 0.5 9.2 +/- 2.3 23.9 +/- 1.1 27.3 +/- 3.3 17.7 +/- 1.2 12.2 +/- 3.3 23.8 +/- 1.4 70.5 +/- 4.2 178.2 +/- 3.3 263.9 +/- 6.9 54.7 +/- 2.1 11.9 +/-0.9 33.0 +/- 1.5 9965.0 +/- 250.0 12.7 +/- 0.2 19.6 +/- 2.4 27.3 +/- 1.1 35.4 42.1 29.3 119.0 54.3 50.3 88.6 56.5 25.3 18.9 8060.0 13.4 18.2 4.6 58.2 19.0 19.4 33.5 68.9 61.3 54.6 27.1 11.5 7.7 9.1 25.1 27.4 18.2 12.6 23.2 71.1 180.0 251.0 58.6 9.7 28.9 9700.0 12.9 17.9 27.5 26.7 -44.1 33.4 - 50.8 20.6 - 38.0 109.0 - 129.0 45.6 - 63.0 41.6 - 59.0 73.3 - 104.0 32.0 -81.0 16.6 -34.0 13.7 -24.1 6660.0 - 9450.0 9.9 - 16.9 10.3 -26.1 0.0 -9.8 49.5 - 66.9 10.3 -27.7 10.7 -28.1 24.8 - 42.2 60.2 - 77.6 52.6 - 70.0 45.2 -64.0 15.4 -38.8 2.8 -20.2 5.7 -9.7 5.2 - 13.1 19.9 -30.3 19.3 -33.9 12.9 -21.6 8.6 - 15.5 19.9 -28.3 58.0 - 78.2 162.0 - 200.0 226.0 - 294.0 30.6 - 72.9 4.3 - 18.2 24.0 - 33.8 8430.0 - 10700.0 9.6 - 14.9 12.0 -21.5 22.1 - 30.8 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

' Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates (ERA).

Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

c Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

A1-1

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)".

Concentration (pCi/L)

Lab Code Date Analysis Laboratory ERA Control Resulte Resultc Limits Acceptance Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing In drinking water conducted by Environmental Resources Associates (ERA).

b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

c Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

d The reported result was an average of three analyses, results ranged from 25.36 to 29.23 pCi/L.

A fourth analysis was performed, result of analysis, 24.89 pCI/L.

Al -2

TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLD, CaSO4: Dy Cards).

mR Lab Code Date Known Lab Result Control Description Value

+ 2 sigma Limits Acceptance Environmental, Inc.

2007-1 2007-1 2007-1 2007-1 2007-1 2007-1 2007-1 2007-1 2007-1 2007-1 2007-1 7/13/2007 7/13/2007 7/13/2007 7/13/2007 7/13/2007 7/13/2007 7/13/2007 7/13/2007 7/13/2007 7/13/2007 7/13/2007 30 cm.

40 cm.

50 cm.

60 cm.

70 cm.

80 cm.

90 cm.

100 cm.

110 cm.

120 cm.

150 cm.

30 cm.

40 cm.

60 cm.

70 cm.

80 cm.

90 cm.

110 cm.

120 cm.

120 cm.

150 cm.

180 cm.

54.25 30.51 19.53 13.56 9.96 7.63 6.03 4.88 4.03 3.39 2.17 54.37 30.59 13.59 9.99 7.65 6.04 4.04 3.4 3.4 2.17 1.51 60.56 +/- 5.54 34.23 +/- 0.96 17.95 +/- 1.86 16.61 +/- 0.60 9.72 +/- 0.90 7.79 +/- 0.33 5.53 +/- 0.72 5.32 +/- 0.17 3.49 +/- 0.14 2.64 +/- 0.14 2.13 +/- 0.87 65.47 +/- 5.25 37.43 +/- 2.18 15.18 +/- 0.50 12.18 +/- 0.46 8.74 +/- 0.39 5.89 +/- 0.25 4.13 +/- 0.41 2.92 +/- 0.13 2.91 +/- 0.31 1.95 +/- 0.72 1.38 +/- 0.05 37.98 - 70.53 21.36 - 39.66 13.67 - 25.39 9.49 - 17.63 6.97 - 12.95 5.34 - 9.92 4.22 - 7.84 3.42 -6.34 2.82 - 5.24 2.37 - 4.41 1.52 -2.82 38.06 - 70.68 21.41 - 39.77 9.51 - 17.67 6.99 - 12.99 5.36 - 9.95 4.23 - 7.85 2.83 - 5.25 2.38 -4.42 2.38 - 4.42 1.52 -2.82 1.06 -1.96 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Environmental, Inc.

2007-2 11/12/2007 2007-2 11/12/2007 2007-2 11/12/2007 2007-2 11/12/2007 2007-2 11/12/2007 2007-2 11/12/2007 2007-2 11/1.2/2007 2007-2 11/12/2007 2007-2 11/12/2007 2007-2 11/12/2007 2007-2 11/12/2007 A2-1

TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)3 Lab Code b Date Analysis Laboratory results Known Control 2s, n=l c Activity Limits d Acceptance W-30707 W-30707 SPAP-1 566 SPAP-1566 SPW-1 568 SPW-1678 SPW-1595 SPW-1 595 SPW-1595 SPW-1 595A SPW-1595B SPMI-1597 SPMI-1597 SPMI-1597 SPMI-1597A SPMI-1597B SPCH-2839 SPW-2847 SPW-2847 SPW-2847 SPMI-2849 SPMI-2849 SPMI-2849 SPCH-2922 SPW-2847 SPW-2847 SPW-2847 SPMI-2849 SPW-2909 SPW-2911 SPAP-2913 SPAP-2915 SPAP-2915 SPF-2922 SPF-2922 SPW-3223 W-60507 W-60507 SPW-4327 SPW-5476 W-92107 W-92107 3/7/2007 3/7/2007 3/23/2007 3/23/2007 3/23/2007 3/28/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/18/2007 5/18/2007 5/18/2007 5/18/2007 5/22/2007 5/22/2007 5/22/2007 5/22/2007 5/22/2007 5/22/2007 5/22/2007 5/24/2007 6/5/2007 6/5/2007 7/18/2007 8/17/2007 9/21/2007 9/21/2007 Gr. Alpha Gr. Beta Cs-134 Cs-137 H-3 Tc-99 Cs-1 34 Cs-137 1-131(G) 1-131 1-131 Cs-134 Cs-1 37 1-131(G) 1-131 1-131 1-131(G)

Cs-134 Cs-137 1-131(G)

Cs-134 Cs-137 1-131(G) 1-131(G) 1-131 Sr-89 Sr-89 1-131 Fe-55 H-3 Gr. Beta Cs-134 Cs-137 Cs-134 Cs-137 Ni-63 Gr. Alpha Gr. Beta Tc-99 Ni-63 Gr. Alpha Gr. Beta 19.51 +/- 0.40 67.45 +/- 0.49 25.35 +/- 1.31 107.52 +/- 3.02 65595.00 +/- 672.00 28.44 +/- 1.12 54.48 +/-2.12 59.03 +/- 2.94 83.11 +/-3.51 78.40 +/- 1.10 78.97 +/- 1.10 54.03 +/- 2.15 59.81 +/- 4.75 83.97 +/- 4.07 79.53 +/- 1.03 83.51 +/- 1.05 78.70 +/- 7.36 55.43 +/- 1.68 59.86 +/-.2.71 63.95 +/- 2.69 51.37 +/- 1.65 60.42 +/- 4.31 62.44 +/- 3.14 80.00 +/- 6.40 60.14 +/- 0.89 104.93 +/- 6.64 46.72 +/- 1.97 67.97 +/- 0.88 11137.00 +/- 316.00 65023.00 +/- 679.00 55.27 +/- 8.51 22.53 +/- 1.12 111.14 +/- 3.57 0.52 +/- 0.03 2.58 +/- 0.07 2233.10 +/- 10.32 20.93 +/- 0.42 60.50 +/- 0.46 25.58 +/- 1.11 1925.18 +/- 9.62 23.02 +/- 0.44 61.48 +/- 0.47 20.08 65.73 27.82 116.48 71118.00 32.35 54.99 58.19 82.07 82.07 82.07 54.99 58.19 82.07 82.07 82.07 70.40 52.85 58.03 70.87 52.85 58.03 70.87 70.40 70.87 121.90 46.08 70.87 14271.50 70485.00 52.65 26.42 116.06 0.53 2.32 2135.90 20.08 65.73 32.35 2135.90 20.08 65.73 10.04 - 30.12 55.73 - 75.73 17.82 - 37.82 104.83 - 128.13 56894.40 - 85341.60 20.35 - 44.35 44.99 - 64.99 48.19 - 68.19 72.07 - 92.07 65.66 - 98.48 65.66 - 98.48 44.99 - 64.99 48.19 - 68.19 72.07 - 92.07 65.66 - 98.48 65.66 - 98.48 60.40 - 80.40 42.85 - 62.85 48.03 - 68.03 60.87 - 80.87 42.85 - 62.85 48.03 - 68.03 60.87 - 80.87 41.60 - 99.20 56.70 - 85.04 97.52 - 146.28 36.08 - 56.08 56.70 - 85.04 11417.20 - 17125.80 56388.00 - 84582.00 42.12 - 73.71 16.42 - 36.42 104.45 - 127.67 0.32 - 0.74 1.39 - 3.25 1281.54 - 2990.26 10.04 - 30.12 55.73 - 75.73 20.35 - 44.35 1281.54 -2990.26 10.04 - 30.12 55.73 - 75.73 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A3-1

TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)r Lab Code Date Analysis Laboratory results Known Control 2s, n=lb Activity Limitsc Acceptance SPW-6880 w-1 11007 w-111007 SPAP-7742 SPAP-7742 SPAP-7744 SPMI-7746 SPMI-7746 SPMI-7746 SPW-7748 SPW-7748 SPW-7748 SPW-7752 SPW-7758 SPF-7760 SPF-7760 SPW-8034 10/10/2007 11/10/2007 11/10/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 Tc-99 Gr. Alpha Gr. Beta Cs-1 34 Cs-1 37 Gr. Beta Cs-134 Cs-1 37 Sr-90 Cs-1 34 Cs,137 Sr-90 Fe-55 H-3 Cs-134 Cs-137 Ni-63 30.97 +/- 1.21 22.43 +/- 0.42 64.49 +/- 0.48 21.18 +/- 1.29 113.61 +/-3.16 53.41 +/- 0.13 42.20 +/- 1.48 56.05 +/- 2.83 41.02 +/-1.61 43.11 +/-1.52 59.28 +/- 3.50 37.23 +/- 1.51 12935.10 +/- 357.00 65405.00 + 712.50 0.45 +/- 0.02 2.45 +/- 0.07 2194.06 +/- 10.77 32.35 20.08 65.73 22.41 114.76 52.03 44.83 57.40 45.54 44.80 57.40 45.54 12640.50 68618.00 0.45 2.29 2129.03 20.35 - 44.35 10.04 - 30.12 55.73 - 75.73 12.41 - 32.41 103.28 - 126.24 41.62 - 72.84 34.83 - 54.83 47.40 - 67.40 36.43 - 54.65 34.80 - 54.80 47.40 - 67.40 36.43 - 54.65 10112.40 - 15168.60 54894.40 - 82341.60 0.27 -0.63 1.37 -3.21 1277.42 - 2980.64 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

" Liquid sample results are reported In pCi/Liter, air filters( pCi/filter), charcoal (pCi/m 3), and solid samples (pCi/g).

b Laboratory codes as follows: W (water), MI (milk), AP (air filter), SO (soil), VE (vegetation),

CH (charcoal canister), F (fish).

c Results are based on single determinations.

0 Control limits are based on Attachment A, Page A2 of this report.

e Sample recount: 12557 +/- 335.

NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.

A3-2

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysisb Laboratory results (4.66a)

Acceptance Type LLD Activityc Criteria (4.66 a)

W-30707 W-30707 SPAP-1567 SPW-1567 SPW-1568 SPW-1596 SPW-1596 SPW-1596 SPW-1 596 SPMI-1598 SPMI-1598 SPMI-1598 SPMI-1598 SPCH-2839 SPW-2848 SPW-2848 SPW-2848 SPMI-2850 SPMI-2850 SPMI-2850 SPW-2848 SPW-2848 SPW-2848 SPMI-2850 SPMI-2850 SPMI-2850' SPAP-2914 SPAP-2916 SPAP-2916 SPF-2923 SPF-2923 SPW-3224 W-60507 W-60507 SPW-4328 SPW-5477 W-92107 W-92107 water water Air Filter Air Filter water water water water water Milk Milk Milk Milk Charcoal Canister water water water Milk Milk Milk water water water Milk Milk Milk Air Filter Air Filter Air Filter Fish Fish water water water water water water water 3/7/2007 3/712007 3/23/2007 3/23/2007 3/23/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 4/5/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/17/2007 5/18/2007 5/18/2007 5/18/2007 5/18/2007 5/18/2007 5/18/2007 5/22/2007 5/22/2007 5/22/2007 5/22/2007 5/22/2007 5/24/2007 6/5/2007 6/5/2007 7/18/2007 8/17/2007 9/21/2007 9/21/2007 Gr. Alpha Gr. Beta Cs-1 34 Cs-1 37 H-3 Cs-1 34 Cs-1 37 1-131 1-131(G)

Cs-134 Cs-137 1-131 1-131(G) 1-131(G)

Cs-134 Cs-137 1-131(G).

Cs-134 Cs-137 1-131(G) 1-131 Sr-89 Sr-90 1-131 Sr-89 Sr-90 Gr. Beta Cs-134 Cs-1 37 Cs-134 Cs-137 Ni-63 Gr. Alpha Gr. Beta Tc-99 Ni-63 Gr. Alpha Gr. Beta 0.40 0.75 0.79 1.01 176.10 3.28 3.45 0.27 2.91 3.30 5.08 0.26 4.10 2.24 3.14 1.37 5.34 3.32 2.60 4.77 0.34 0.81 0.53 0.45 0.96 0.58 0.004 2.84 2.24 8.71 8.35 1.61 0.43 0.77.

6.41 1.48 0.41 0.75 0.01 +/- 0.28 0.06 +/- 0.53

-26.16 +/- 91.62 0.02 +/- 0.18

-0.10 +/- 0.17

-0.06 +/- 0.19

-0.02 +/- 0.65 0.01 +/- 0.25 0.20 +/- 0.26

-0.73 +/- 1.02 0.96 +/- 0.38

-0.002 +/- 0.002

-0.30 +/- 0.84

-0.01 +/- 0.30 0.01 +/- 0.54

-3.12 +/- 3.84 4.38 +/- 1.01 0.09 +/- 0.29

-0.26 +/- 0.51 2

4 100 100 200 10 10 0.5 20 10 10 0.5 20 9.6 10 10 20 10 10 20 0.5 5

1 0.5 5

1 0.01 100 100 100 100 20 2

4 10 20 2

4 A4-1

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)8 Lab Code Sample Date Analysisb Laboratory results (4.66o)

Acceptance Type LLD Activityc Criteria (4.66 a)

SPW-6881 SPAP-7743 SPMI-7745 SPMI-7745 SPMI-7745 SPMI-7745 SPW-7747 SPW-7747 SPW-7747 SPW-7747 SPW-7751 SPW-7757 SPF-7759 SPF-7759 SPW-8033 W-120607 W-120607 water Air Filter Milk Milk Milk Milk water water water water water water Fish Fish water water water 10/10/2007 11113/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 11/13/2007 12/6/2007 12/6/2007 Tc-99 Gr. Beta Cs-134 Cs-1 37 1-131(G)

Sr-90 Cs-134 Cs-137 1-131(G)

Sr-90 Fe-55 H-3 Cs-1 34 Cs-1i37 Ni-63 Gr. Alpha Gr. Beta 6.82 0.003 2.16 3.46 5.89 0.59 2.39 3.53 12.51 0.71 15.50 151.35 5.50 5.10 1.45 0.40 0.77

-6.58 +/- 4.04

-0.002 +/- 0.002 0.73 +/- 0.35

-0.04 +/- 0.32

-4.18 +/- 9.20

-14.98 +/- 78.85

-0.19 +/- 0.87 0.02 +/- 0.28

-0.70 +/- 0.51 10 0.01 10 10 20 1

10 10 20 1

1000 200 100 100 20 2

4

' Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).

b 1-131(G); iodine-131 as analyzed by gamma spectroscopy.

c Activity reported is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not reported.

d Low levels of Sr-90 are still detected in the environment. A concentration of (1-5 pCi/L) in milk is not unusual.

A4-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)'

Averaged Lab Code Date Analysis First Result Second Result Result Acceptance E-20, 21 E-20, 21 CF-41, 42 CF-41, 42 CF-41, 42 P-9516, 9517 LW-9579, 9580 DW-70085, 70086 DW-70037, 70038 DW-70054, 70055 DW-70122, 70123 DW-70122, 70123 DW-70098, 70099 DW-70110, 70111 SWU-676,677 DW-70148, 70149 SW-600, 601 SW-601, 602 DW-1138, 1139 MI-721, 722 SW-847, 848 SW-847, 848 DW-70175, 70176 DW-70187, 70188 SWU-1162, 1163 DW-70205, 70206 PW-1117, 1118 PW-1117, 1118 W-2122, 2123 W-2122, 2123 W-2085, 2086 W-2085, 2086 DW-70232, 70233 WW-1477, 1478 WW-1498, 1499 W-2140, 2141 W-2140, 2141 DW-1626, 1627 MI-1647, 1648 DW-70248, 70249 W-2150, 2151 W-2150, 2151 LW-1941, 1942 1/2/2007 1/2/2007 12/2007 1/2/2007 1/2/2007 1/3/2007 1/4/2007 1/9/2007 1/11/2007 1/18/2007 1/18/2007 1/18/2007 1/25/2007 1/25/2007 1/30/2007 1/30/2007 2/1/2007 2/1/2007 2/9/2007 2/13/2007 2/13/2007 2/13/2007 2/14/2007 2/14/2007 2/27/2007 2128/2007 3/1/2007 3/1/2007 3/5/2007 3/5/2007 3/6/2007 3/6/2007 3/8/2007 3/12/2007 3/15/2007 3/19/2007 3/19/2007 3/21/2007 3/21/2007 3/21/2007 3/26/2007 3/2612007 3/31/2007 Gr. Beta K-40 Gr. Beta K-40 Sr-90 H-3 Gr. Beta Gr. Alpha Gr. Alpha Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha K-40 Gr. Beta H-3 K-40 Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Beta Gr. Alpha Gr. Beta H-3 K-40 Gr. Alpha Gr. Alpha Gr. Beta Gr. Beta 1.76 +/- 0.07 1.49 +/- 0.24 18.02 +/- 0.41 11.68 +/- 1.12 0.039 +/- 0.011 270.78 +/- 91.74 0.91 +/- 0.31 7.95 +/- 1.20 55.47 +/- 3.99 2.68 +/- 0.88 4.30'+/- 1.14 4.22 +/- 0.70 3.27 +/- 0.90 2.19 +/- 0.92 1.77 +/- 0.39 4.65 +/- 1.37 1.24 +/- 0.12 0.89 +/- 0.37 2707.00 +/- 161.00 1330.40 +/- 117.60 3.82 +/- 1.67 7.33 +/- 1.37 11.72 +/- 1.68 6.79 +/- 1.18 3.63 +/- 0.69 0.88 +/- 0.80 3.79 +/- 1.91 7.12 +/- 1.40 6.10 +/- 4.16 10.65 +/- 2.15 2.51 +/- 2.29 11.02 +/- 1.85 4.75 +/- 1.28 6.41 +/- 1.48 0.83 +/- 0.31 2.31 +/- 1.57 4.26 +/- 1.00 4973.00 +/- 209.00 1448.80 +/- 120.20 11.10 +/- 1.18 3.56 +/- 2.20 9.26 +/- 1.00 1.35 +/- 0.43 1.70 +/- 0.06 1.57 +/- 0.27 18.81 +/- 0.42 12.67 +/- 0.97 0.026 +/- 0.010 301.18 +/- 92.99 0.93 +/- 0.30 7.92 +/- 1.42 52.87 +/- 4.02 1.88 +/- 0.78 6.25 +/- 1.16 5.33 +/- 0.75 1.97 +/- 0.92 1.69 +/- 0.79 2.11 +/- 0.39 5.20+/- 1.81 1.20 +/- 0.12 1.02 +/- 0.25 2700.00 +/- 161.00 1316.40 +/- 116.50 2.61 +/- 1.24 5.89 +/- 0.90 8.84 +/- 1.32 6.47 +/- 1.08 2.61 +/- 0.44 1.31 +/- 0.79 3.62 +/- 2.09 7.20 +/- 1.39 3.80 +/- 4.30 13.11 +/- 2.42 1.10 +/- 2.78 9.50 +/- 2.01 5.98 +/- 1.31 4.10 +/- 1.25 0.97 +/- 0.33 1.33 +/- 1.64 5.58 +/- 1.02 5190.00 +/- 213.00 1439.30 +/- 126.00 9.90 +/- 1.16 3.30 +/- 1.81 10.17 +/- 1.90 1.36 +/- 0.41 1.73 +/- 0.05 1.53 +/- 0.18 18.42 +/- 0.29 12.18 +/- 0.74 0.033 +/- 0.007 285.98 +/- 65.31 0.92 +/- 0.22 7.94 +/- 0.93 54.17 +/- 2.83 2.28 +/- 0.59 5.28 +/- 0.81 4.78 +/- 0.51 2.62 +/- 0.64 1.94 +/- 0.61 1.94 +/- 0.28 4.93 +/- 1.14 1.22 +/- 0.08 0.96 +/- 0.22 2703.50 +/- 113.84 1323.40 +/- 82.77 3.22 +/- 1.04 6.61 +/- 0.82 10.28 +/- 1.07 6.63 +/- 0.80 3.12 +/- 0.41 1.10 +/- 0.56 3.71 +/- 1.42 7.16 +/- 0.99 4.95 +/- 2.99 11.88 +/- 1.62 1.81 +/- 1.80 10.26 +/- 1.37 5.37 +/- 0.92 5.26 +/- 0.97 0.90 +/- 0.22 1.82 +/- 1.14 4.92 +/- 0.71 5081.50 +/- 149.21 1444.05 +/- 87.07 10.50 +/- 0.83 3.43 +/- 1.42 9.72 +/- 1.07 1.36 +/- 0.30 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-1

TABLE A-5. In-House "Duplicate" Samples Concentration (pCiVL)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance MI-1824, 1825 MI-1824, 1825 AP-2170, 2171 WW-1850, 1851 AP-2198, 2199 AP-2370, 2371 DW-70300, 70301 DW-70300, 70301 DW-70335, 70336 DW-70335, 70336 SW-1898, 1899 SW-1898, 1899 SW-1898, 1899 DW-70346, 70347 DW-70346, 70347 DW-70376, 70377 DW-70376, 70377 DW-70311, 70312 WW-2349, 2350 WW-2461,2462 LW-2437, 2438 LW-2917, 2918 SO-2583, 2584 SO-2583, 2584 SO-2583, 2584 SO-2583, 2584 SO-2583, 2584 SO-2583, 2584 S-2620, 2621 MI-2610, 2611 W-4469, 4470 SS-2697, 2698 SS-2697, 2698 MI-2790, 2791 W-4505, 4506 DW-3219, 3220 SO-3416, 3417 SO-3416, 3417 SO-3416, 3417 F-3561, 3562 SL-3311, 3312 SL-3311, 3312 4/2/2007 4/2/2007 4/2/2007 4/3/2007 4/3/2007 4/3/2007 4/4/2007 4/4/2007 4/5/2007 4/5/2007 4/10/2007 4/1012007 4/10/2007 4/11/2007 4/11/2007 4/11/2007 4/11/2007 4/12/2007 4/17/2007 4/25/2007 4/26/2007 4/30/2007 5/1/2007 5/1/2007 5/1/2007 5/1/2007 5/11/2007 5/11/2007 5/2/2007 5/3/2007 5/7/2007 5/8/2007 5/8/2007 5/14/2007 5/14/2007 5/26/2007 5/31/2007 5/31/2007 5/31/2007 5/31/2007 6/4/2007 6/4/2007 K-40 Sr-90 Be-7 H-3 Be-7 Be-7 Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta H-3 Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha H-3 Gr. Beta Gr. Beta Be-7 Cs-137 K-40 Gr. Alpha Gr. Beta Sr-90 H-3 K-40 Gr. Beta Cs-137 K-40 K-40 Gr. Beta 1-131 Cs-137 Gr. Beta K-40 K-40 Be-7 K-40 1316.10 +/- 110.60 1.20 +/- 0.50 0.08 +/- 0.01

-5.83 +/- 102.29 0.08 +/- 0.01 0.07 +/- 0.01 3.78 +/- 0.89 2.93 +/- 0.61 24.37 +/- 2.89 20.26 +/- 1.37 3.86 +/- 1.40 6.31 +/- 1.36 241.99 +/- 93.35 1.83 +/- 1.08 4.62 +/- 0.72 1.81 +/- 0.80 1.84 +/- 0.62 10.82 +/- 1.50 0.71 +/- 0.56 190.30 +/- 100.31 2.71 +/- 0.50 1.97 +/- 0.79 544.99 +/- 247.70 119.22 +/- 36.61 17825.00 +/- 749.90 11.49 +/- 3.96 31.02 +/- 3.74 0.086 +/- 0.024 277.90 +/- 126.70 1549.20 +/- 184.20 10.60 +/- 1.90 0.06 +/- 0.02 8.03 +/- 0.57 1694.30 +/- 126.20 3.30 +/- 1.70 0.62 +/- 0.32 0.15 +/- 0.03 22.88 +/- 2.33 12.26 +/- 0.80 3.06 +/- 0.39 0.61 +/- 0.29 5.78 +/- 0.67 1229.80 +/- 110.50 1.10 +/- 0.36 0.08 +/- 0.01 150.05 +/- 80.14 0.08 +/- 0.01 0.07 +/- 0.01 3.66 +/- 0.96 2.91 +/- 0.64 22.72 +/- 2.91 18.33 +/- 1.34 4.78 +/- 1.51 7.03 +/- 1.42 318.10 +/- 96.48 2.54 +/- 1.04 4.01 +/- 0.71 1.66 +/- 0.86 2.24 +/- 0.61 13.20 +/- 1.56 0.62 +/- 0.52 115.95 +/- 97.65 2.15 +/- 0.45 2.78 +/- 0.81 601.13 +/- 192.20 87.46 +/- 23.97 17672.00 +/- 724.30 8.04 +/-3.88 26.10 +/- 3.40 0.068 +/- 0.025 304.40 +/- 101.00 1388.80 +/- 128.20 11.10 +/- 1.80 0.05 +/- 0.03 7.36 +/- 0.68 1627.60 +/- 128.80 3.90 +/- 1.50 0.69 +/- 0.31 0.15 +/- 0.03 22.46 +/- 2.37 12.36 +/- 0.65 3.37 +/- 0.45 0.55 +/- 0.25 4.87 +/- 0.25 1272.95 +/- 78.17 1.15 +/- 0.31 0.08 +/- 0.01 72.11 +/-64.97 0.08 +/- 0.01 0.07 +/- 0.01 3.72 +/- 0.65 2.92 +/- 0.44 23.55 +/- 2.05 19.30 +/- 0.96 4.32 +/- 1.03 6.67 +/- 0.98 280.04 +/- 67.12 2.19 +/- 0.75 4.32 +/- 0.51 1.74 +/- 0.59 2.04 +/- 0.44 12.01 +/- 1.08 0.66 +/- 0.38 153.13 +/- 70.00 2.43 +/- 0.34 2.38 +/- 0.57 573.06 +/- 156.76 103.34 +/- 21.88 17748.50 +/- 521.29 9.77 +/- 2.77 28.56 +/- 2.53 0.077 +/- 0.017 291.15 +/- 81.02 1469.00 +/- 112.21 10.85 +/- 1.31 0.05 +/- 0.02 7.70 +/- 0.44 1660.95 +/- 90.16 3.60 +/- 1.13 0.66 +/- 0.22 0.15 +/- 0.02 22.67 +/- 1.66 12.31 +/- 0.52 3.21 +/- 0.30 0.58 +/- 0.19 5.33 +/- 0.36 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SL-3992, 3993 SL-3992, 3993 SL-3992, 3993 W-5087, 5088 SW-3710, 3711 W-4062, 4063 W-4062, 4063 AP-4448, 4449 SG-3735, 3736 SG-3735, 3736 SG-3735, 3736 SG-3735, 3736 LW-4175, 4176 SG-5422, 5423 SG-5422, 5423 AP-4656, 4657 AP-4763, 4764 SG-5430, 5431 SG-5430, 5431 SG-5430, 5431 SG-5430, 5431 SG-5430, 5431 WW-4298, 4299 DW-70612, 70613 WW-4918, 4919 MI-4742, 4743 VE-4939, 4940 VE-4939, 4940 VE-4939, 4940 SG-6274, 6275 SG-6274, 6275 SW-5218, 5219 SG-6284, 6285 SG-6284, 6285 SG-6284, 6285 SG-6284, 6285 WW-5310, 5311 SW-5393, 5394 SW-5393, 5394 W-5468, 5469 6/4/2007 6/4/2007 6/4/2007 6/1112007 6/14/2007 6/28/2007 6/28/2007 6/28/2007 6/30/2007 6/30/2007 6/30/2007 6/30/2007 6/30/2007 7/2/2007 7/2/2007 7/3/2007 7/3/2007 7/11/2007 7/11/2007 7/11/2007 7/1112007 7/11/2007 7/12/2007 7/23/2007 7/25/2007 7/26/2007 8/1/2007 8/1/2007 8/1/2007 816/2007 8/6/2007 817/2007 8/8/2007 8/8/2007 8/8/2007 8/8/2007 8/9/2007 8/14/2007 8/14/2007 8/15/2007 Be-7 Gr. Beta K-40 Gr. Beta H-3 Gr. Alpha Gr. Beta Be-7 Be-7 Cs-137 Gr. Beta K-40 Gr. Beta Gr. Alpha Gr. Beta Be-7 Be-7 Be-7 Cs-1 37 Gr. Alpha Gr. Beta K-40 Gr. Beta Gr. Alpha H-3 K-40 Be-7 Gr. Beta K-40 Gr. Alpha Gr. Beta 1-131 Cs-137 Gr. Alpha Gr. Beta K-40 H-3 Gr. Beta H-3 H-3 0.75 +/- 0.19 13.61 +/- 1.12 2.43 +/- 0.36 8.70 +/- 1.90 9571.51 +/- 287.22 0.76 +/- 0.63 0.97 +/- 0.53 0.10 +/- 0.02 0.84 +/- 0.12 0.07 +/- 0.01 29.51 +/- 2.22 9.41 +/- 0.31 2.18 +/- 0.60 10.31 +/- 1.98 18.59 +/- 1.46 0.09 +/- 0.02 0.11 +/- 0.02 10.17 +/- 0.48 0.050 +/- 0.010 17.86 +/- 2.78 26.19 +/- 1.74 7.69 +/- 0.30 1.74 +/- 0.74 4.54 +/- 1.11 240.43 +/- 111.12 1820.30 +/- 134.10 0.39 +/- 0.21 5.50 +/- 0.14 3.36 +/- 0.45 16.68 +/- 3.29 40.93 +/- 2.74 1.31 +/- 0.24 0.043 +/- 0.006 9.38 +/- 2.93 33.46 +/- 2.84 16.15 +/- 0.24 644.00 +/- 106.00 2.32 +/- 1.31 190.06 +/- 86.80 262.58 +/- 108.43 0.74 +/- 0.32 14.06 +/- 1.08 2.29 +/- 0.40 7.70 +/- 1.90 9879.21 +/- 291.42 0.32 +/- 0.66 0.58 +/- 0.57 0.09 +/- 0.02 0.82 +/- 0.18 0.07 +/- 0.01 30.81 + 2.22 8.90 +/- 0.48 1.93 +/- 0.68 10.57 +/- 1.99 20.97 +/- 1.49 0.10 +/- 0.02 0.10 +/- 0.02 10.06 +/- 0.51 0.059 +/- 0.011 15.74 +/- 2.70 25.04 +/- 1.86 7.65 +/- 0.28 2.22 +/- 0.80 4.19 +/- 0.97 216.68 +/- 110.27 1802.90 +/- 199.50 0.45 +/- 0.20 5.76 +/- 0.13 3.36 +/- 0.21 19.26 +/- 3.39 42.42 +/- 2.66 1.42 +/- 0.24 0.051 +/- 0.007 13.61 +/- 3.38 32.87 +/- 2.93 16.23 +/- 0.25 831.00 +/- 113.00 1.71 +/- 1.27 69.05 +/- 80.88 346.53 +/- 111.42 0.75 +/- 0.19 13.84 +/- 0.78 2.36 +/- 0.27 8.20 +/- 1.34 9725.36 +/- 204.59 0.54 +/- 0.45 0.78 +/- 0.39 0.10 +/- 0.01 0.83 +/- 0.11 0.07 +/- 0.01 30.16 +/- 1.57 9.16 +/- 0.29 2.06 +/- 0.45 10.44 +/- 1.40 19.78 +/- 1.04 0.10 +/- 0.01 0.11 +/-0.01 10.12 +/- 0.35 0.055 +/- 0.007 16.80 +/- 1.94 25.62 +/- 1.27 7.67 +/- 0.21 1.98 +/- 0.55 4.37 +/- 0.74

.228.56 +/- 78.27 1811.60 +/- 120.19 0.42 +/- 0.15 5.63 +/- 0.10 3.36 +/- 0.25 17.97 +/- 2.36 41.68 +/- 1.91 1.37 +/-0.17 0.047 +/- 0.005 11.50 +/- 2.24 33.17 +/- 2.04 16.19 +/- 0.17 737.50 +/- 77.47 2.02 +/- 0.92 129.55 +/- 59.32 304.55 +/- 77.74 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-3

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-5553, 5554 WW-5643, 5644 SWU-5799, 5800 DW-70752, 70753 VE-5917, 5918 VE-5917, 5918 VE-5917, 5918 MI-6009, 6010 MI-6030, 6031 MI-6030, 6031 DW-70718, 70719 DW-70718, 70719 SO-6156, 6157 SO-6484, 6485 SO-6484, 6485 SO-6484, 6485 WW-6469, 6470 E-6647, 6648 E-6647, 6648 WW-6656, 6657 TD-7080, 7081 SG-6891, 6892 SG-6891, 6892 AP-7191, 7192 WW-6786, 6787 WW-6786, 6787 VE-6828, 6829 VE-6828, 6829 VE-6828, 6829 SS-6870, 6871 SS-6870, 6871 LW-7507, 7508 MI-6933, 6934 MI-6933, 6934 MI-7059, 7060 F-7213, 7214 F-7213, 7214 WW-7408, 7409 DW-70856, 70857 SO-7508, 7509 SO-7508, 7509 SO-7508, 7509 8/22/2007 8/22/2007 8/28/2007 8/31/2007 9/4/2007 9/4/2007 9/4/2007 9/11/2007

.9/12/2007 9/12/2007 9/12/2007 9/12/2007 9/14/2007 9/17/2007 9/1712007 9/17/2007 9/21/2007 10/11/2007 10/1/2007 10/1/2007 10/2/2007 10/3/2007 10/3/2007 10/3/2007 10/8/2007 10/8/2007 10/8/2007 10/8/2007 10/8/2007 10/9/2007 10/9/2007 10/11/2007 10/16/2007 10/16/2007 10/17/2007 10/24/2007 10/24/2007 10/24/2007 10/24/2007 10/26/2007 10/26/2007 10/26/2007 K-40 H-3 Gr. Beta Gr. Alpha Be-7 K-40 Gr. Beta K-40 K-40 Sr-90 Gr. Alpha Gr. Beta H-3 Cs-137 Gr. Beta K-40 Gr. Beta Gr. Beta K-40 Gr. Beta H-3 Gr. Alpha Gr. Beta Be-7 H-3 H-3 Gr. Alpha Gr. Beta K-40 Gr. Beta K-40 Gr. Beta K-40 Sr-90 K-40 H-3 K-40 H-3 Gr. Alpha Cs-137 Gr. Beta K-40

,1.89 +/- 0.33 259.00 +/- 110.00 2.64 +/- 1.18 14.41 +/- 1.48 0.94 +/- 0.17 3.73 +/- 0.37 2.71 +/- 0.10 1348.90 +/- 113.40 1242.70 +/- 118.00 1.00 +/- 0.38 23.04 +/- 3.71 16.13 +/- 1.59 181.99 +/- 90.67 0.01 +/- 0.00 24.20 +/- 2.60 11.52 +/- 1.16 27.19 +/- 2.51 1.82 +/- 0.10 1.48 +/- 0.24 2.80 +/- 0.97 332.00 +/- 229.00 12.93 +/- 2.12 18.08 +/-1.41 0.09 +/- 0.01 13333 +/- 322 13188 +/- 322 0.06 +/- 0.04 5.55 +/- 0.21 5.45 +/- 0.43 18.10 +/- 2.08 10.19 +/- 0.66 1.40 +/- 0.56 1386.60 +/- 104.70 1.73 +/- 0.52 1424.80 +/- 106.60 6.83 +/- 0.22 3.13 +/-0.51 340.71 +/- 90.45 11.03 +/- 1.66 0.30 +/- 0.04 34.43 +/- 2.72 16.84 +/- 0.84 1.89 +/- 0.22 266.00 +/- 110.00 3.62 +/- 1.06 12.90 +/- 1.50 0.83 +/- 0.20 3.58 +/- 0.36 2.69 +/- 0.10 1388.10 +/- 116.40 1475.60 +/- 119.60 0.90 +/- 0.34 23.22 +/- 3.61 17.36 +/- 1.69 232.19+/- 92.95 0.01 +/- 0.00 23.30 +/- 2.30 10.89 +/- 1.10 24.23 +/- 2.29 1.93 +/- 0.11 1.31 +/- 0.23 1.95 +/- 0.87 383.00 +/- 191.00 13.52 +/- 2.07 18.27 +/- 1.36 0.09 +/- 0.01 13532 +/-324 13556 +/-326 0.06 +/- 0.05 5.20 +/- 0.22 5.20 +/- 0.49 21.71 +/- 2.19 9.72 +/- 0.68 1.44 +/- 0.54 1331.20 +/- 106.70 2.17 +/- 0.57 1448.60 +/- 115.30 7.24 +/- 0.22 3.16 +/- 0.48 346.22 +/- 90.67 10.71 +/- 1.34 0.29 +/- 0.05 37.25 +/- 3.07 17.43 +/- 1.05 1.89 +/- 0.20 262.50 +/- 77.78 3.13 +/- 0.79

.13.66 +/- 1.05 0.89 +/- 0.13 3.66 +/- 0.26 2.70 +/- 0.07 1368.50 +/- 81.25 1359.15 +/- 84.01 0.95 +/- 0.26 23.13 +/- 2.59 16.75 +/- 1.16 207.09 +/- 64.92 0.01 +/- 0.00 23.75 +/- 1.74 11.20 +/- 0.80 25.71 +/- 1.70 1.88 +/- 0.07 1.40 +/- 0.17 2.38 +/- 0.65 357.50 +/- 149.10 13.23 +/- 1.48 18.18 +/- 0.98 0.09 +/- 0.01 13433 +/-228 13372 +/-229 0.06 +/- 0.03 5.38 +/- 0.10 5.32 +/- 0.33 19.90 +/- 1.51 9.95 +/- 0.47 1.42 +/- 0.39 1358.90 +/- 74.74 1.95 +/- 0.39 1436.70 +/- 78.51 7.03 +/- 0.16 3.15 +/- 0.35 343.46 +/- 64.03 10.87 +/- 1.07 0.29 +/- 0.03 35.84 +/- 2.05 17.14 +/- 0.67 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-4

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)r Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SS-7529, 7530 SS-7529, 7530 SW-7589, 7590 SWU-7733, 7734 MI-7618, 7619 VE-7666, 7667 VE-7666, 7667 VE-7666, 7667 DW-7853, 7854 MI-7874, 7875 WW-8142, 8143 DW-8094, 8095 F-8328, 8329 WW-8378, 8379 10/29/2007 10/29/2007 10/30/2007 10/30/2007 10/31/2007 11/5/2007 11/5/2007 11/5/2007 11/9/2007 11/14/2007 11/28/2007 11/29/2007 12/11/2007 12/11/2007 Cs-137 K-40 Gr. Beta Gr. Beta K-40 Gr. Alpha Gr. Beta K-40 1-131 K-40 Gr. Beta Gr. Beta Gr. Beta H-3 0.12 +/- 0.03 11.85 +/- 0.68 1.75 +/- 0.29 1.66 +/- 1.01 1376.80 +/- 114.30 0.07 +/- 0.04 6.03 +/- 0.15 5.82 +/- 0.36 1.61 +/- 0.40 1407.70 +/- 101.30 9.51 +/- 2.21 1.60 +/- 0.58 3.97 +/- 0.08 296.00 +/- 103.00 0.12 +/- 0.02 11.75 +/- 0.58.

1.24 +/- 0.26 2.43 +/- 1.13 1426.70 +/- 128.80 0.16 +/- 0.05 6.13 +/- 0.15 5.74 +/- 0.36 1.08 +/- 0.39 1362.60 +/- 114.50 7.86 +/- 2.01 1.25 +/- 0.54 4.00 +/- 0.08 407.00 +/- 107.00 0.12 +/- 0.02 11.80 +/- 0.45 1.50 +/- 0.19 2.05 +/- 0.76 1401.75 +/- 86.10 0.11 +/- 0.03 6.08 +/- 0.10 5.78 +/- 0.25 1.35 +/- 0.28 1385.15 +/- 76.44 8.68 +/- 1.49 1.43 +/- 0.40 3.99 +/- 0.05 351.50 +/- 74.26 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Duplicate analyses are performed on every twentieth sample received in-house. Results are not listed for those analyses with activities that measure below the LLD.

B Results are reported in units of pCi/L, except for air filters (pCi/Filter), food products, vegetation, soil, sediment (pCi/g).

A5-5

TABLEA-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STW-1110 01/01/07 Gr.Alpha STW-1110 01/01/07 Gr. Beta 0A45 +/- 0.08 0.90 +/- 0.14 0.33 0.85 0.00 - 0.65 0.43 - 1.28 s-rw-111 e STW-1 111 STW-1111 STW-1111 STW-1111 STW-1111 STW-1111 STW-1111 STW-1111 STW-1111 STW-1111 STW-1111 STW-1111 S-W--1111 STW-1111

,STW-1111 STSO-1112f STSO-1112 STSO-1112 STSO-1112 STSO-1112 STSO-1112 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 Am-241 Co-57 Cs-134 Cs-137 Fe-55 H-3 Mn-54 Ni-63 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 Am-241 Co-57 Co-60 Cs-1 34 Cs-137 Mn-54 2.80 +/- 0.21 151.60 +/- 10.00 79.20 +/- 8.00 168.70 +/- 12.10 130.30 +/- 19.90 262.20 +/- 9.10 130.60 +/- 11.50 127.80 +/- 3.60 127.80 +/- 3.60 2.03 +/- 0.17 2.27 +/- 0.17 9.60 +/- 1.40 8.80 +/- 1.50 2.44 +/- 0.21 2.44 +/- 0.21 123.70 +/- 17.00 46.40 +/- 9.00 501.20 +/- 2.90 285.90 +/- 2.10 325.90 +/- 7.40 855.70 +/- 4.60 750.90 +/- 4.70 1.71 143.70 83.50 163.00 129.30 283.00 123.80 130.40 130.40 2.25 2.22 8.87 88.00 2.49 2.48 114.80 34.80 471.20 274.70 327.40 799.70 685.20 1.20 -2.22 100.60- 186.80 58.50 - 108.60 114.10 - 211.90 90.50 -168.10 198.10 - 367.90 86.70 - 160.90 91.30 - 169.50 91.30 -169.50 1.58 -2.93 1.55 -2.89 6.21 -11.53 7.40 - 13.70 1.74 - 3.24 1.74-3.22 80.40 - 149.20 24.40 - 45.20 329.80 -612.60 192.30 - 357.10 229.20 - 425.60 559.80 - 1039.60 479.60 - 890.80 Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STAP-1113 01/01/07 Gr. Alpha STAP-1113 01/01/07 Gr. Beta STAP-1 114 STAP-1 114 STAP-1 114 STAP-1 114 STAP-1 114 STAP-1114 STAP-1 114 STAP-1 114 STAP-1 114 STAP-1 114 STAP-1 114 STAP-1 114 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 Am-241 Co-57 Co-60 Cs-1 34 Cs-I 37 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 0.27 +/- 0.04 0.57 +/- 0.05 0.10 +/- 0.03 3.51 +/- 0.07 2.98 +/- 0.10 4.02 +/- 0.16 2.75 +/- 0.12 3.94 +/- 0.12 0.07 +/- 0.01 0.08 +/- 0.01 0.58 +/- 0.18 0.09 +/- 0.01 0.09 +/- 0.01 2.70 +/- 0.10 0.60 0.44 0.10 2.89 2.91 4.20 2.57 3.52 0.07 0.08 0.61 0.10 0.10 2.68 0.00-1.20 0.22 -0.66 0.07 -0.13 2.02 - 3.75 2.03 - 3.78 2.94 - 5.45 1.80-3.34 2.46 - 4.57 0.05 - 0.09 0.06 -0.11 0.43 - 0.79 0.07 -0.13 0.07-0.13 1.88 - 3.49 A6-1

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STVE-1 115 STVE-1 115 STVE-1 115 STVE-1115 STVE-1115 01/01/07 01/01/07 01/01/07 01/01/07 01/01/07 Co-57 Co-60 Cs-134 Cs-137 Mn-54 8.90 +/- 0.20 6.50 +/- 0.20 6.90 +/- 0.30 8.20 +/- 0.30 10.10 +/- 0.30 8.19 5.82 6.21 6.99 8.46 5.73 - 10.64 4.08 - 7.57 4.35 - 8.07 4.90 - 9.09 5.91 - 10.98 Pass Pass Pass Pass Pass Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the Department of Energy's Mixed Analyte Performance Evaluation Program, Idaho Operations office, Idaho Falls, Idaho b Results are reported in units of Bq/kg (soil), Bq/L (water) or Bq/total sample (filters, vegetation).

c Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

d MAPEP results are presented. as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP.

e Result of reanalysis, 2.08 +/- 0.13 pCi/L.

1The test samples were recounted on lower background detectors. Result of the recounts: 41.4 +/- 6.3 Bq/kg.

A6-2

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCi/L)

Lab Code b Date Analysis Laboratory ERA Control Result c Result d Limits Acceptance STAP-1 116 03/19/07 Gr. Alpha STAP-1 116 03/19/07 Gr. Beta 34.64 +/- 2.56 93.41 +/- 3.20 25.8 79.5 12.4 - 39 48.8 -116 STAP-1117 STAP-1117 STAP-1 117 STAP-1117 e STAP-1117' STAP-1117' STAP-1117 STAP-1117 STAP-1117 STAP-1 117 STAP-1117 STAP-1117 STAP-1117 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118t STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118 STSO-1118f

.03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 Am-241 Co-60 Cs-1 34 Cs-137 Fe-55 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 Ac-228 Am-241 Bi-212 Co-60 Cs-134 Cs-137 K-40 Mn-54 Pb-212 Pb-214 Pu-238 Pu-239/40 Sr-90 Th-234 U-233/4 U-238 Uranium Uranium Zn-65 56.04 +/- 3.90 1610.00 +/- 8.40 1340.40 +/- 48.84 345.30 +/- 8.20

< 134.0

<5.0 43.32 +/- 2.28 35.23 +/- 2.24 156.10 +/- 6.60 42.22 +/- 1.84 42.00 +/- 1.84 85.79 +/- 3.60 363.80 +/- 11.90 3097.77 +/- 94.96 1000.70 +/- 156.10 2467.87 +/- 114.33 7847.40 +/- 86.60 7910.60 +/- 356.88 4635.00 +/- 99.10 12201.60 +/- 423.20

<34.0 2046.80 +/- 127.20 4142.80 +/- 110.40 1099.20 +/- 73.10 1586.10 +/- 82.00 6163.30 +/- 791.60 4329.40 +/- 569.10 3236.70 +/- 106.00 3425.20 +/- 134.00 6787.80 +/- 240.00 6787.80 +/- 240.00 0.00 +/- 0.00 57.5 1300.0 1120.0 255.0 0.0 0.0 37.4 31.6 156.0 47.8 47.4 97.3 245.0 2790.0 927.0 2500.0 7330.0 7560.0 4300.0 11100.0 0.0 1730.0 3330.0 857.0 1360.0 7500.0 3590.0 3620.0 3590.0 7380.0 7380.0 0.0 33.1 -80 1010.0 - 1620 732.0 -1380 192.0 -336 25.7 -49 22.9 -41 66.6 - 246 30.1 -71 30.2 -68 49.5-155 208.0 -412 1790.0 -3930 548.0 -1200 658.0 -3730 5340.0 - 9820 4850.0 - 9070 3290.0 -5580 8050.0 -15000 1120.0 -2430 1980.0 -4980 490.0 -1200 928.0 -1810 2610.0 -12400 2190.0 - 4560 2280.0 -4520 2190.0 -4560 4210.0 - 9930 4210.0 -9930 0.0-0 Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A7-1

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)".

Concentration (pCi/L)

Lab Code b Date Analysis Laboratory ERA Control Result c Result d Limits Acceptance STVE-1119 STVE-1119 STVE-1 119 STVE-1119 STVE-1119 STVE-1119 STVE-1119' STVE-1 119 STVE-1119 STVE-1119 STVE-1119 STVE-1119 STVE-1119 STVE-1 119 STW-1120 STW-1120 STW-1120 STW-1120 STW-1 120 STW-1 120' STW-1120 STW-1120 STW-1 120 STW-1120 STW-1120 STW-1120 STW-1120 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19/07 03/19407 03/19/07 03/19/07 03/19/07 03/19/07 Am-241 Cm-244 Co-60 Cs-1 34 Cs-1 37 K-40 Mn-54 Pu-238 Pu-239/40.

Sr-90 U-233/4 U-238 Uranium Zn-65 Am-241 Co-60 Cs-134 Cs-137 Fe-55 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 3249.60 +/- 150.30 1860.70 +/- 91.50 2827.90 +/- 62.40 654.80 +/- 48.40 3307.30 +/- 58.80 40814.20 +/- 618.80

< 27.6 2762.00 +/- 251.10 2156.60 +/- 83.40 8999.70 +/- 580.90 2821.90 +/- 73.50 2896.10 +/- 50.70 5718.00 +/- 124.15 474.30 +/- 45.70 133.50 +/- 10.60 541.40 +/- 9.00 1623.80 +/- 66.10 1839.10 +/- 17.90 829.50 +/- 226.80

<8.1 123.30 +/- 4.30 95.10 +/- 3.80 949.40 +/- 16.70 164.20 +/- 6.58 169.20 +/- 8.22 339.60 +/- 10.66 2009.00 +/- 36.40 3550.0 1840.0 2600.0 579.0 2920.0 37900.0 0.0 2430.0 1900.0 8890.0.

2940.0 2910.0 5980.0 366.0 179.0 536.0 1750.0 1850.0 671.0 0.0 116.0 90.9 989.0 192.0 190.0 391.0 1910.0 2020.0 - 4890 905.0 -2870 1760.0 - 3720 308.0- 822 2150.0 - 4060 27200.0 - 53600 1250.0 - 3600 1180.0 - 2600 4900.0 - 11800 1930.0 - 3920 2090.0 - 3610 4110.0 - 7770 267.0 - 500 123.0 -243 467.0 - 631 1290.0 - 2020 1570.0 - 2220 392.0 -896 87.6 - 144 70.3-113 630.0 - 1320 145.0 -247 145.0 -236 282.0 - 521 1600.0 - 2410 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML).

b Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

c Unless otherwise indicated, the laboratory result Is given as the mean +/- standard deviation for three determinations.

d Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

'A high bias (- 20%) was observed in gamma results for air filters. A composite filter geometry was used in the calculations vs. a single filter geometry. Result of recalculation. Cs-137, 305.8 +/- 6.0 pCi/filter, f Included in the testing series as a "false positive". No activity expected.

A7-2

Appendix B Summary Tables in the format of NRC Radiological Assessment Branch Technical Position Revision 1, November 1979 Page B-1

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2007 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Air Particulate (pCi/m 3)

Gross Beta (318) 0.01 0.030 (265/265)

(0.010-0.062) 0.091 (20/20)

(0.060-0.114) 49 0.8 miles NNE 37 2.0 miles NNW 0.030(53/53)

(0.016-0.062) 0.099 (4/4)

(0.089-0.114)

Station 48 0.029 (52/53)

(0.015-0.053) 0.087 (4/4)

(0.067-0.106) 0 Gamma (24)

Be-7 1-131 (318) 0 0

0.07

- (0/265)

N/A N/A

-(0/53)

External Radiation (mR/day)

Stations 39 & 48 0.210 (16/16)

(0.192-0.241)

TLD (344) 0.212 (328/328)

(0.139-0.278) 38 1.2 miles NW 0.236 (8/8)

(0.213-0.260) 0 Surface Water (pCi/I)

Gamma (24)

Tritium (24)

-(0/12)

N/A N/A 3000 10442 (12/12)

(8262-12910)

SP 3.2 miles SSE 10442 (12/12)

(8262-12910)

JRR

-(0/12)

-(0/12)

B-12

-(0/4)

-(0/4)

-(0/4) 0 0

Ground Water (pCi/I) 1-131 (31) 1 Gamma (31)

Tritium (31)

-(0/27)

-(0/27)

-(0/27)

N/A N/A N/A N/A N/A N/A 0

0 0

2000 Page B-2

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2007 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Drinking Water (pCil/)

1-131 (24)

Gross Beta (24)

Gamma (24)

Tritium (8) 1

-(0/12)

N/A IO-DW 26.1 miles SSE N/A BW-15

-(0/12) 3.0 (12/12)

(2.4-4.3) 4 3.2 (12/12)

(2.3-4.4) 3.2 (12/12)

(2.3-4.4) 0 0

0 0

-(0/12)

N/A N/A N/A N/A

-(0/12)

-(0/4) 2000

-(0/4)

Shoreline Sediment (pCi/kg dry)

Gamma (7)

JRR 11886(2/2)

(11685-12087)

K-40 11545.4 (5/5)

(10851-12250)

SC 0.8 miles NNW 12250(1/1) 0 0

Cs-1 37 180

-(0/5)

N/A N/A 108.2 (1/2)

Fish (pCi/kg wet)

Gamma (17)

K-40 Tritium (17)

JRR 2893.4 (11/11)

(2302.9-3428.8) 6475 (11/11)

(5505-7266)

CCL 0.6 miles CCL 0.6 miles 2893.4 (11/11)

(2302.9-3428.8) 3174.4 (6/6)

(2889.0-3681.5) 0 0

6475 (11/11)

(5505-7266)

-(0/6)

Page B-3

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2007 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Food and Garden (pCi/kg wet)

Gamma (22)

Be-7 K-40 1049.5 (8/13)

(282.7-2727.4) 4281.2 (13/13)

(2495.7-8289.2)

Q-6 2.4 miles NW Q-6 2.4 miles NW 1463.9 (3/4)

(282.7-2727.4) 5234.0 (4/4)

(2495.7-8289.2)

D-2 742.4 (6/9)

(472.3-973.8) 5744.4 (9/9)

(3900.0-8653.1) 0 0

NR-U1 Crops (pCi/kg wet)

Bottom Sediment (pCi/kg dry)

Gamma (5)

K-40 6454.9 (3/3)

(1378.5-14596)

NR-D2 11.5 miles S 8993.2 (2/2)

(3390.3-14596) 9399.3 (2/2)

(2854.6-15944) 0 Gamma (6)

JRR K-40 Co-60 Cs-1 37 10948.1 (4/4)

(7502.3-13569) 98.3 (2/4)

(88.7-107.9) 173.7 (2/4)

(167.7-179.8)

DC 0.9 miles WNW DC 0.9 miles WNW DC 0.9 miles WNW 13185(2/2)

(12801-13569) 98.3 (2/2)

(88.7-107.9) 173.7(2/2)

(167.7-179.8) 15196 (2/2)

(14889-15503)

-(0/2) 0 0

0 125.4 (2/2)

(121.5-129.3)

Page B-4

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2007 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Aquatic Vegetation (pCi/kg wet)

Gamma (2)

No Control Be-7 K-40 Terrestrial Vegetation (pCi/kg wet)

Gamma (2)

Be-7 K-40 724.1 (2/2)

(285.4-1162.7) 2944.4 (2/2)

(2504.1-3384.6) 573.5 (2/2)

(407.5-739.5) 5797.1 (2/2)

(4592.7-7001.4) 10353.2 (2/2)

(9090.3-11616) 386.3 (2/2)

(326.4-446.2)

EEA 3.0 miles NNW EEA 3.0 miles NNW 1162.7(1/1) 3384.6 (1/1)

No Control 0

0 EEA 3.0 miles NNW EEA 3.0 miles NNW 739.5 (1/1) 7001.4 (1/1) 0 0

Soil (pCi/kg dry)

Gamma (2)

No Control K-40 MUDS 1.5 miles WNW EEA 3.0 miles NNW 11616(1/1) 446.2 (1/1) 0 0

Cs-137 Page B-5

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

Air Particulate and Charcoal Filters Location:

002 Gross Beta Collection Collection.

Volume Concentration Start Date End Date M3 (pC0im 3 )

Concentration Duplicate (PCiJrri 3).

Analysis 27-DEC-06 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 26-SEP-07 353 271 318 310 318 319 320 310 299 299 325 288 310 311 316 347 309 303 350 264 339 255 342 255 299 300 300 258 327 281 300 293 251 351 296 298 347 256 299 305

0. 022+/-
0. 019+/-
0. 037+/-
0. 033+/-

0.028+/-

0. 028+/-

0.028+/-

0.030+/-

0. 020+/-
0. 018+/-

0.027+/-

0. 034+/-

0.026+/-

0. 019+/-

0.019+/-

0. 025+/-
0. 021+/-

0.027 +/-

0. 013+/-

0.018+/-

0.028+/-

0.037+/-

0.019+/-

0.017+/-

0.023+/-

0.027+/-

0.020+/-

0.010+/-

0.027+/-

0.034+/-

0.025+/-

0.035+/-

0.046+/-

0.041+/-

0. 037+/-

0.024+/-

0.037+/-

0.029+/-

0.032+/-

0.047+/-

0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.003 0.004 0.004 0.004 0.003 0.003 0.003 0.004 0.004 0.003 0.004 0.004 0.005 0.003 0.004 0.004 0.004 0.004 0.003 0.004

0. 004 0.004 0.004 0.005 0.004 0.004 0.003 0.004 0.004 0.004 0.004 K

K 0.016 0.012 0.010 0.014 0.011 0.013 0.016 0.010 0.016 0.014 0.011 0.011 0.015 0.018 0.009 0.010 0.008 0.018 0.016 0.006 0.016 0.008 0.012 0.016 0.018 0.018 0.032 0.015 0.014 0.017 0.011 0.021 0.012 0.013 0.014 0.019 0.021 0.015 0.013 Duplicate K

K 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 1

Air Particulate and Charcoal Filters Location:

002 4Collecto

>3/4Start Date Collection Volumea End Date M3 Gross Beta 1-131.

Concentration Concentration (p~i/M3 (pCi/m 3 )

Duplicate.

2Analysis 26-SEP-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 24-OCT-07 31-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 31-OCT-07 07-NOV-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-JAN-08 307 308 375 224 295 295 299 299 292' 256 366 301 304 343 313 292 0.038+/-

0.004 0.021+/-

0.004 0.024+/-

0.003 0.027+/-

0.004 0.025+/-

0.004 0.016 0.018 0.015 0.014 0.013 0.011 0.030+/-

0.031+/-

0.026+/-

0.045+/-

0.033+/-

0.030+/-

0.038+/-

0.039+/-

0.055+/-

0.048+/-

0.039+/-

0.004 0.004 0.004

0. 005 0.005 0.003 0.004 0.004 0.005 0.005 0.004 Duplicate Duplicate K

K K

K 0.012 0.012 0.009 0.012 0.018 0.014 0.020 0.020 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 2

Air Particulate and Charcoal Filters Location:

018 Grs ea 1-131:

S, Collection Collection Y olume Concentration Concentration Duplicate

<Start Date~

End D~ate M3 (pciI&ý)

(3/4.M Analysis 27-DEC-06 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 338 258 308 293 307 296 295 298 299 314 303 303 307 308 294 299 309 299 367 265 336 251 349 257 301 313 301 269 345 345 293 309 299 267 353 288 300 355 262 301 0.023+/-

0.017+/-

0.031+/-

0.034+/-

0.024+/-

0.031+/-

0.036+/-

0.027+/-

0.017+/-

0.025+/-

0.035+/-

0.034+/-

0.026+/-

0.018+/-

0.019+/-

0.024+/-

0.020+/-

0.023+/-

0.016+/-

0.017+/-

0.028+/-

0. 026+/-

0.018+/-

0. 022+/-

0.021+/-

0.027+/-

0.021+/-

0. 013+/-

0.028+/-

0. 028+/-

0.031+/-

0.027 +/-

0. 037+/-
0. 047+/-
0. 038+/-

0.039+/-

0.027+/-

0. 036+/-

0.033+/-

0.031+/-

0.003 0.004 0.004 0.004

0. 004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.003 0.004 0.004
0. 004
0. 004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 K

K K

K K

K K

K K

K K

0.017 0.012 0.011 0.015 0.011 0.014 0.017 0.010 0.016 0.015 0.011 0.012 0.015 0.019 0.011 0.010 0.008 0.017 0.016 0.006 0.016 0.008 0.012 0.016 0.018 0.018 0.031 0.014 0.013 0.016 0.011 0.020 0.012 0.013 0.014 0.018 0.021 0.015 Duplicate Duplicate K

K K

K K

K K

K K

K 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 3

Air Particulate and Charcoal Filters Location:

018 Collection.

S~tart Date~

19-SEP-07 26-SEP-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 07-NOV-07 14-NOV-07 14-NOV-07 20-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 27-DEC-07 collection

'End Date 26-SEP-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 14-NOV-07 20-NOV-07 20-NOV-07 28-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-JAN-08 03-JAN-08 Gross Beta 1-131;:

VoIuMe~ Concentration,

<Concentra~tion Duplicate M3 (pCi/M 3).

(pCiIin3 ')

Analysis 305 303 303 385 223 297 303 294 294 264 264 355 355 301 303 356 305 302 302 0.044+/-

0. 039+/-

0.020+/-

0.023+/-

0.026+/-

0.028+/-

0.028+/-

0.054+/-

0.056+/-

0.028+/-

0.029+/-

0. 032+/-

0.033+/-

0.040+/-

0.041+/-

0. 052 +/-

0.044+/-

0.041+/-

0.042+/-

0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004

0. 005 0.004 0.004 0.013 0.016 0.018 0.015 0.014 0.013 0.011 0.012 0.012 0.009 Duplicate Duplicate Duplicate 0.012 0.018 0.013 0.020 0.019 Duplicate 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 4

Air Particulate and Charcoal Filters Location:

032 27-DEC-06 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 26-SEP-07 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 26-SEP-07 03-OCT-07 358 276 308 289 304 299 305 306 299 326 299 314 314 311 291 312 300 355 271 344 253 350 258 308 300 306 265 351 291 303 301 259 355 296 304 362 268 298 303 310 0.022+/-

0.015+/-

0. 027 +/-

0.034+/-

0.026+/-

0.029+/-

0.029+/-

0.026+/-

0.020+/-

0.022+/-

0.038+/-

0.025+/-

0.018+/-

0.017+/-

0.023+/-

0.022+/-

0. 026+/-

0.015+/-

0.017+/-

0.031+/-

0.030+/-

0.019+/-

0.020+/-

0.023+/-

0.028+/-

0.020+/-

0.013-/-

0.031+/-

0.030+/-

0.026+/-

0.034+/-

0.046+/-

0.041+/-

0.035+/-

0.026+/-

0. 037 +/-
0. 028+/-
0. 027+/-

0.042+/-

0.035+/-

0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.003 0.004 0.004 0.003 0.003 0.004 0.004 0.004 0.003 0.004 0.004 0.005 0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004

0. 003 0.004 0.004 0.004 0.004 0.004 0.016 0.012 0.011 0.015 0.012 0.014 0.016 0.010 0.016 0.014 0.011 0.011 0.015 0.018 0.011 0.010 0.008 0.018 0.016 0.005 0.016 0.008 0.012 0.016 0.018 0.018 0.031 0.014 0.013 0.017 0.011
0. 021 0.012 0.013 0.014 0.018 0.020 0.015 0.013 0.016 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

5

Air Particulate and Charcoal Filters Location:

032

<~

, Gross Beta 1-13T Collection Collection Volume>

Concentration Cocnrto Dulct Start Date End Date M3 j(pCiirn3)

(p~i/m3 )

Anpualysi 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-JAN-08 308 384 221 297 302 290 262 357 301 308 355 310 310 0.029+/-

0.022+/-

0.027+/-

0.028+/-

0.030+/-

0.049+/-

0.027+/-

0.035+/-

0.040+/-

0.043+/-

0.050+/-

0.045+/-

0.039+/-

0.004 0.003 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 K

K K

K K

K K

K K

K K

K 0.018 0.015 0.014 0.013 0.011 0.012 0.012 0.009 0.012 0.018 0.013 0.020 0.019 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 6

Air Particulate and Charcoal Filters Location:

037 27-DEC-06 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 06-SEP-07 12-SEP-07 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 12-SEP-07 19-SEP-07 342 262 308 295 309 289 284 301 303 318 289 304 304 308 314 253 311 294 351 270 342 258 344 259 309 313 311 267 351 298 308 308 266 360 300 298 353 261 261 301

0. 021+/-

0.019+/-

0.032+/-

0.032+/-

0. 028+/-
0. 028+/-
0. 028+/-

0.027 +/-

0. 019+/-
0. 023+/-

0.037+/-

0. 024+/-

0.026+/-

0.020+!-

0.020+/-

0. 029+/-

0.024+/-

0. 025+/-
0. 018+/-

0.017+/-

0.029+/-

0.029+/-

0. 016+/-
0. 021+/-

0.022 +/-

0.024 +/-

0. 020+/-
0. 012+/-

0.029+/-

0. 031+/-

0.024 +/-

0.032+/-

0.044+/-

0.038+/-

0. 038+/-

0.025+/-

0.043+/-

0. 028+/-

0.032+/-

0.035+/-

0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004

0. 003 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.003 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.003 0.003 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.003 0.004 0.004 0.004 0.004 K

K K

K K

K K

K K

K K

0.017 0.012 0.011 0.014 0.011 0.015 0.018 0.010 0.016 0.015 0.011 0.012 0.015 0.018 0.013 0.010 0.008 0.018 0.016 0.006 0.015 0.008 0.012 0.015 0.018 0.018 0.031 0.014 0.013 0.016 0.010 0.020 0.011 0.013 0.014 0.018 0.021 Duplicate Duplicate 0.015 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 7

Air Particulate and Charcoal Filters Location:

037 19-SEP-07 19-SEP-07 26-SEP-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 26-SEP-07 26-SEP-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 05-DEC-07 12-DEC-07 20-DEC-07 20-DEC-07 27-DEC-07 03-JAN-08 303 303 306 311 384 222 294 302 298 267 376 304 304 304 348 348 293 323

0. 047+/-

0.044+/-

0. 041+/-

0.021+!-

0.027+/-

0.024+/-

0. 030+/-
0. 030+/-
0. 041+/-

0.028+/-

0.035+/-

0. 041+/-
0. 040+/-

0.043+/-

0. 057+/-
0. 058+/-

0.047+/-

0. 043+/-

0.004 0.004 0.004 0.004

0. 003 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.005 0.005 0.005 0.004 0.013 Duplicate K

K K

K K

K K

K 0.016 0.018 0.015 0.014 0.013 0.011 0.012 0.012 0.009 0.011 0.018 0.014 0.014 0.021 0.018 Duplicate Duplicate 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 8

Air Particulate and Charcoal Filters Location:

048 27-DEC-06 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 26-SEP-07 338 260 308 295 304 298 310 311 298 12 68 295 304 305 298 306 307 358 266 266 330 263 354 268 301 300 298 266 343 122 293 300 54 337 296 300 351 263 299 298 0.019+/-

0.015+/-

0.031+/-

0.039+/-

0.026+/-

0.027+/-

0.034+/-

0.027+/-

0.019+/-

0.024+/-

0. 051 +/-

0.026+/-

0.019+/-

0.021+/-

0.022+/-

0.020+/-

0.024+/-

0.015+/-

0.016+/-

0.016+/-

0.029+/-

0.032+/-

0. 020+/-
0. 021+/-

0.024+/-

0.033+/-

0.022+/-

0. 020+/-
0. 028+/-
0. 029+/-
0. 027 +/-
0. 035+/-
0. 039+/-

0.034 +/-

0.024+/-

0.037 +/-

0.026+/-

0. 033+/-

0.037+/-

0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.062 0.013 0.004 0.003 0.004 0.004 0.004 0.004

0. 003 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.007 0.004 0.004 0.021 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.017 0.012 0.011 0.014 0.012 0.014 0.016 0.010 0.016 0.386 0.048 0.012 0.015 0.018 0.011 0.010 0.008 0.018 0.016 0.006 0.015 0.008 0.012 0.016 0.018 0.018 0.031 0.014 0.032 0.017 0.011
0. 100 0.012 0.013 0.014 0.018 0.021 0.015 0.014 Duplicate K

K 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

9

Air Particulate and Charcoal Filters Location:

048 26-SEP-07 03-OCT-07 10-OCT-07 10-OCT-07 19-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-OCT-07 10-OCT-07 19-OCT-07 19-OCT-07 24-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-JAN-08 301 318 376 376 219 219 296 300 298 267 353 308 303 350 308 306 0.034+/-

0.020+/-

0.026+/-

0.024+/-

0.024+/-

0.020+/-

0.022+/-

0.028+/-

0.036+/-

0.031+/-

0.025+/-

0.039+/-

0.040+/-

0.053+/-

0.047+/-

0.040+/-

0.004 0.003 0.003 0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.005 0.004 0.016 0.017 0.015 0.014 Duplicate Duplicate K

K K

K K

K K

0.013 0.011 0.012 0.012 0.009 0.011 0.018 0.013 0.020 0.019 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

10

Air Particulate and Charcoal Filters Location:

049

-Gross Beta

.1-131:

Collection Collection Volume Concentration C

moncentration Duplicate s

Start Date End Date m3S,(pCi/m

3)

(pCi/m 3)

Analysis 27-DEC-06 27-DEC-06 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 04-JAN-07 04-JAN-07 10-JAN-07 17-JAN-07 24-JAN-07 31-JAN-07 07-FEB-07 14-FEB-07 21-FEB-07 28-FEB-07 07-MAR-07 14-MAR-07 21-MAR-07 28-MAR-07 04-APR-07 11-APR-07 18-APR-07 25-APR-07 03-MAY-07 09-MAY-07 17-MAY-07 23-MAY-07 31-MAY-07 06-JUN-07 13-JUN-07 20-JUN-07 27-JUN-07 03-JUL-07 11-JUL-07 18-JUL-07 25-JUL-07 01-AUG-07 07-AUG-07 15-AUG-07 22-AUG-07 29-AUG-07 06-SEP-07 12-SEP-07 19-SEP-07 26-SEP-07 342 342 267 313 295 303 309 305 305 303 320 294 312 317 316 298 312 295 358 271 340 252 346 255 301 300 296 264 341 287 301 301 256 343 303 298 355 264 298 300

0. 022+/-

0.024+/-

0. 019+/-
0. 033+/-

0.037+/-

0. 030+/-
0. 028+/-
0. 030+/-

0.025+/-

0. 018+/-
0. 026+/-
0. 033+/-

0.026+/-

0. 019+/-
0. 018+/-

0.023+/-

0.024+/-

0.026+/-

0.018+/-

0.017+/-

0.031+/-

0.028+/-

0.017+/-

0. 019+/-
0. 020+/-
0. 029+/-
0. 026+/-

0.016+/-

0. 029+/-
0. 029+/-
0. 023+/-

0.033+/-

0. 044+/-

0.041+/-

0.041+/-

0.030+/-

0.038+/-

0.033+/-

0. 033+/-

0.044+/-

0.003

0. 003
0. 004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.003 0.003 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.003
0. 004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.017 Duplicate 0.012 0.010 0.014 0.012 0.014 0.016 0.010 0.016 0.015 0.011 0.011 0.015 0.018 0.011 0.010 0.008 0.018 0.016 0.006 0.016
0. 008 0.012 0.016 0.018 0.019 0.032 0.014 0.014 0.017 0.011 0.021 0.012 0.013 0.014 0.018 0.021 0.015 0.014 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

11

Air Particulate and Charcoal Filters Location:

049 Collection Collection Volume*

~Start Date Enid Date M3 Gross Beta Concentration C

Concentration Duplicate:

p* lni3)

Analysis 26-SEP-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-OCT-07 10-OCT-07 19-OCT-07 24-OCT-07 31-OCT-07 07-NOV-07 14-NOV-07 20-NOV-07 28-NOV-07 05-DEC-07 12-DEC-07 20-DEC-07 27-DEC-07 03-JAN-08 308 300 379 224 294 304 294 264 356 306 303 349 306 310 0.049+/-

0.025+/-

0.023+/-

0.027+/-

0.030+/-

0.026+/-

0.043+/-

0.032+/-

0.037+/-

0.040+/-

0. 062+/-

0.058+/-

0.046+/-

0.041+/-

0.005 0.004 0.003 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.005 0.005 0.005 0.004 K

K K

K K

K K

K K

K K

K K

0.016 0.018 0.015 0.014 0.013 0.011 0.012 0.012 0.009 0.011 0.018 0.014 0.020 0.019 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

12

Quarterly Air Particulate - Gamma Location: 002 28-MAR-07 Nuclide.

Concentratiin (pCi/r)

BE-7

.103+/-

0.015 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JUL-07 Nucide-Conc~entration (pCiini3)

BE-7

.098+/-

0.020 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-OCT-07 Nuclide ConcentrationilpCi/W3..

BE-7

.097+/-

0.013 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JAN-08 Nuclide7~

BE-7 CO-58

.in-centration (Pcilm 3

.071+/-

0.014 0.001 Co CS CS FE

-60 0.001

-134 0.001

-137 0.001

-59 0.002

13

Quarterly Air Particulate - Gamma Location: 002 03-JAN-08 ZN-65 0.001 ZR-NB-95 0.001

14

Quarterly Air Particulate - Gamma Location: 018 28-MAR-07 Nuclide Cnetaion (pCin-

-78

.08+6+/-

0. 013 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JUL-07 Nu clide' iE-?T CO-58 CO-60 CS-134 CS-137 FE-59 MN-54 ZN-65 ZR-NB-95
  • Con66entration (C/

3

.088+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 03-OCT-07 Nuclide Cone ntra-tlon (PCinim3) 4, BE-7

.1 +!-

0.013 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JAN-08 BE-7

.06+/-

0.010 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001

15

Quarterly Air Particulate - Gamma Location: 018 03-JAN-08 N~uclide Concentration fpeilm3 MN-54

0. 001 ZN-65 0.001 ZR-NB-95 0.001

16

Quarterly Air Particulate - Gamma Location: 032 28-MAR-07 Nuclide C Concentration (pCii')

BE-7

.076+!-

0.015 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.002 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JUL-07

Nuclider, Concentration(pCiim3)

]

BE-7

.107+!-

0.018 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-OCT-07 Nudide Concentration (pCh6Im)

BE-7

.1+/-

0.015 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JAN-08 Nuclide Concen'traiton (priln31 BE-70.012 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001

17

Quarterly Air Particulate - Gamma Location: 032 03-JAN-08 Nuclide Concentration (pCim 3)

MN-54<

0.001 ZN-65 0.001 ZR-NB-95 0.001

18

Quarterly Air Particulate - Gamma Location: 037 28-MAR-07 Nucide Concentration (pCinim3)

BE-7

.114+/-

0.019 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JUL-07 Nuclide ConcentratiOn (pCi/m3)

BE-7

.094+/-

0.018 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-OCT-07 BE-?7 CO-58 CO-60 CS-134 CS-137 FE-59 MN-54 ZN-65 ZR-NB-95 Concentration (pCiin 3)

.1+!-

0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 03-JAN-08 Nuclide do-nctntration (p im).

BE-7

.089+/-

0.015 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001

19

Quarterly Air Particulate - Gamma Location: 037 03-JAN-08

'Nulide" Concentration (pniým MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001

Quarterly Air Particulate - Gamma Location: 048 28-MAR-07 NuclideConcenitration (PCi/m3) 7 BE-7

.092+/-

0. 013 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.002 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JUL-07 Nuchde

.. Concentrati ioiý (Iý iiY 7 BE-7

.084+!-

0.014 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-OCT-07 Nu*idhe Concentration (pCinim

  • )

BE-7

.106+/-

0.014 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JAN-08 Nuclide.-,

Concentratih (pCi/m3)l BE-7

.067+/-

0.012 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001

21

Quarterly Air Particulate - Gamma Location: 048 03-JAN-08 MN-54 ZN-65 ZR-NB-95

-Co nc-nraiio n (pC urn-)

0.001 0.001 0.001

22

Quarterly Air Particulate - Gamma Location: 049 28-MAR-07 Nuclide:~7 Concentration fpCYWm)

BE-7

.079+!-

0.017 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JUL-07 BE-7 CO-58 CO-60 CS-134 CS-137 FE-59 MN-54 ZN-65 ZR-NB-95

  • Co n.cei

.ration i(yii lnm..

.082+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 03-OCT-07 Nu ilde Concentratio*npCi/m35)

BE-7

.1+/-

0.011 CO-58 0.001 CO-60 0.001 CS-134 0.001 CS-137 0.001 FE-59 0.001 MN-54 0.001 ZN-65 0.001 ZR-NB-95 0.001 03-JAN-08 hBE-7-T CO-58 CO-60 CS-134 CS-137 FE-59 Conenrati on~i (pdGi/*n-P)!

.088+/-

0.016 0.001 0.001 0.001 0.001 0.001 Duplicate Analysis 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 23

Quarterly Air Particulate - Gamma Location: 049 03-JAN-08 MN-54 ZN-65 ZR-NB-95

-Concentrationi (dCi/m 3 )_*

0.001 0.001 0.001

Exposure Pathway - Waterborne Surface Water Location JRR Collection

~

Nuclide Date.

e;

~

Gamma Spectrum & Hl-3~

7<~j Concentration Dulct (pCi/Liter)

Analysis 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 2.800 2.000 5.700 2.500 6.700 2.000 5.800 3.000 2.700 2.100 147.000 2.200 2.300 3.900 1.300

4. 900 2.900 4.400 1.800 3.100 2.400 188.000 2.200 2.500 5.400 3.700
6. 500 2.700 3.400 3.700
4. 600 2.200 180.000 2.200 1.300
2. 600
3. 100 6.000 2.200
2. 600 1.800 Duplicate Duplicate Duplicate Duplicate 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 25

Exposure Pathway - Waterborne Surface Water Location JRR 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 BA-LA-140 BA-LA-140 H-3 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 3.500 3.800 4.000 2.400 8.200 3.700 3.200 2.400 3.100 3.200 3.100 4.000 167.000 167.000 3.900 4.200 4.600 1.800 5.500 2.700 7.200

3. 900 2.800 3.400 180.000 1.700 3.100 6.200
2. 600 3.200
3. 900 4.800 3.200 3.100 2.800 169.000 5.500 3.500 9.300
2. 900 13.200 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 26

Exposure Pathway - Waterborne Surface Water Location JRR

>Collection Nuclidle Concentration Duplicate 4Date (pi/iPr Anialysis 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 08-NOV-07 08-NOV-07 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-G65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58

4. 600 9.400 5.800 4.000 5.400 148.000 2.400
4. 500 5.500 1.500 3.300 3.500 3.100 3.300 3.700
1. 900 156.000 3.600 4.100 10.400 3.100 7.200 2.300 9.300
3. 900 4.400 6.500 193.000 2.500 1.900 5.800 3.200 4.200
3. 900
7. 600 2.700 4.400 4.300 148.000 3.600 3.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 27

Exposure Pathway - Waterborne Surface Water Location JRR 08-NOV-07 08-NOv-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 13-DEC-07 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 8.800 4.100 6.500 4.500 9.500 4.800 7.200

6. 900 176.000 1.700 2.600 2.800
2. 600 6.100 1.700 5.400 2.400 2.200
1. 600 173.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 28

Exposure Pathway - Waterborne Surface Water Location SP 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 11-JAN-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 23-FEB-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 08-MAR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 12-APR-07 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 K

K 12910. 000+/-

K K

K K

K 11985. 000+/-

K K

K K

K 12181. 000+/-

2.000 2.200 5.100

2. 900 1.800 3.300 4.400 2.000
2. 900 2.700 322.000 1.800
2. 900 6.300 2.500
3. 900 3.400 4.200
2. 600 3.300 2.400 306.000 1.700 3.100 4.200
1. 600 4.000 2.800 6.200 2.100 3.500 3.500 311.000 2.700 7.200 4. 900
4. 900
11. 600 5.000 8.100 5.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 29

Exposure Pathway - Waterborne Surface Water Location SP 12-APR-07 12-APR-07 12-APR-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 10-MAY-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 14-JUN-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 18-JUL-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 11391. 000+/-

K K

K K

98 99.000+/

K K

K K

K 9572. 000+/-

K K

K 8262. 000+-

3.700 4.500 309.000 2.500 2.200 4.400 2.300 6.300 3.300 5.400 2.800 3.100 4.200 280.000 2.300 2.400 5.700 3.000 2.000 3.100 7.000

3. 600 2.200 1.900 287.000 3.800
2. 300 3.500 3.300 5.700 2.700 6.400 3.000 2.700
3. 900 263.000 1.600 2.900 5.200 2.600 3.100 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 30

Exposure Pathway - Waterborne Surface Water Location SP Gmmna Spectrum & H-3 Collection' Nuclide Con'centfration Date

'J(pCilLiter)i Duplicate

>Analysis 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 13-SEP-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 11-OCT-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 08-NOV-07 13-DEC-07 13-DEC-07 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 8875.000+!-

K K

8265. 000+/

K 8.200 5.400 2.900 2.700

4. 600 281.000 3.900 5.200 6.500 3.800
8. 500 5.000 10.000 4.400 4.800 7.000 263.000 1.300 1.400 3.600
2. 500 3.000
2. 600 5.100 3.000 2.800 2.300 284.000
3. 300 2.200 5.800 3.400 9.400 4.800
6. 600 5.400
3. 600 8.000 286.000
1. 500 2.000 10063.000+/-

1 10423.000+/-

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 31

Exposure Pathway - Waterborne Surface Water Location SP 13-DEC-07 FE-59 4.600 13-DEC-07 CO-60 1.900 13-DEC-07 ZN-65 3.200 13-DEC-07 ZR-NB-95 2.700 13-DEC-07 1-131 7.800 13-DEC-07 CS-134 3.800 13-DEC-07 CS-137 4.200 13-DEC-07 BA-LA-140 2.600 13-DEC-07 H-3 11474.000+/-

316.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 32

Exposure Pathway - Waterborne Ground Water Location B-12 Collection Nuclide~

Concentration Date~

17pCi/LiterK.

16-FEB-07 MN-54 2.600 16-FEB-07 CO-58 4.500 16-FEB-07 FE-59 9.800 16-FEB-07 CO-60 4.900 16-FEB-07 ZN-65 10.400 16-FEB-07 ZR-NB-95 4.700 16-FEB-07 CS-134 5.200 16-FEB-07 CS-137 4.900 16-FEB-07 BA-LA-140 3.200 16-FEB-07 H-3 135.000 16-FEB-07 1-131 (CHEM) 0.433 18-MAY-07 MN-54 2.000 18-MAY-07 CO-58 3.600 18-MAY-07 FE-59 4.800 18-MAY-07 CO-60 1.900 18-MAY-07 ZN-65 3.200 18-MAY-07 ZR-NB-95 4.600 18-MAY-07 CS-134 3.000 18-MAY-07 CS-137 3.400 18-MAY-07 BA-LA-140 3.100 18-MAY-07 H-3 140.000 18-MAY-07 1-131 (CHEM) 0.293 09-AUG-07 MN-54 5.400 09-AUG-07 CO-58 5.900 09-AUG-07 FE-59 6.000 09-AUG-07 CO-60 3.000 09-AUG-07 ZN-65 11.000 09-AUG-07 ZR-NB-95 5.300 09-AUG-07 CS-134 4.700 09-AUG-07 CS-137 6.600 09-AUG-07 BA-LA-140 8.700 09-AUG-07 H-3 156.000 09-AUG-07 1-131 (CHEM) 0.375 15-NOV-07 MN-54 3.900 15-NOV-07 CO-58 3.200 15-NOV-07 FE-59 4.200 15-NOV-07 CO-60 2.800 15-NOV-07 ZN-65 5.300 15-NOV-07 ZR-NB-95 4.400 15-NOV-07 CS-134 3.300 15-NOV-07 CS-137 3.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

33

Exposure Pathway - Waterborne Ground Water Location B-12 15-NOV-07 BA-LA-140 15-NOV-07 15-NOV-07 H-3 1-131 (CHEM) 4.000 178.000 0.372 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

34

Exposure Pathway - Waterborne Ground Water Location C-10 Collection Date Nuclide Concentration Duplicate 23-FEB-07 MN-54 23-FEB-07 CO-58 23-FEB-07 FE-59 23-FEB-07 CO-60 23-FEB-07 ZN-65 23-FEB-07 ZR-NB-95 23-FEB-07 CS-134 23-FEB-07 CS-137 23-FEB-07 BA-LA-140 23-FEB-07 H-3 18 23-FEB-07 1-131 (CHEM) 18-MAY-07 MN-54 18-MAY-07 CO-58 18-MAY-07 FE-59 18-MAY-07 CO-60 18-MAY-07 ZN-65 18-MAY-07 ZR-NB-95 18-MAY-07 CS-134 18-MAY-07 CS-137 18-MAY-07 BA-LA-140 18-MAY-07 H-3 14 18-MAY-07 1-131 (CHEM) 09-AUG-07 MN-54 09-AUG-07 CO-58 09-AUG-07 FE-59 09-AUG-07 CO-60 09-AUG-07 ZN-65 09-AUG-07 ZR-NB-95 09-AUG-07 CS-134 09-AUG-07 CS-137 09-AUG-07 BA-LA-140 09-AUG-07 H-3 15 09-AUG-07 1-131 (CHEM) 15-NOV-07 MN-54 15-NOV-07 CO-58 15-NOV-07 FE-59 15-NOV-07 CO-60 15-NOV-07 ZN-65 15-NOV-07 ZR-NB-95 15-NOV-07 CS-134 15-NOV-07 CS-137 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station 4.500 3.600 8.600 4.900 5.200 3.500 5.600 5.700 2.600 8.000 0.305 2.200 3.200 2.300 3.200 1.800 2.000 2.500 2.000 1.600 0.000 0.293 2.200 6.200 3.300 3.400 6.900 5.800 3.100 4.200 7.200 6.000 0.398

2. 500 1.100 3.700 2.500 2.400
2. 600 2.400 2.400 Page C - 35

Exposure Pathway - Waterborne Ground Water Location C-10 15-NOV-07 BA-LA-140 15-NOV-07 15-NOV-07 H-3 1-131 (CHEM) 2.400 178.000 0.388 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

36

Exposure Pathway - Waterborne Ground Water Location C-49 Collection Nuclide Concentration

~DateŽ-

(p~i/iiter).

23-FEB-07 MN-54 4.900 23-FEB-07 CO-58 2.300 23-FEB-07 FE-59 6.400 23-FEB-07 CO-60 3.400 23-FEB-07 ZN-65 7.300 23-FEB-07 ZR-NB-95 5.900 23-FEB-07 CS-134 5.900 23-FEB-07 CS-137 6.000 23-FEB-07 BA-LA-140 6.700 23-FEB-07 H-3 188.000 23-FEB-07 1-131 (CHEM) 0.303 18-MAY-07 MN-54 3.600 18-MAY-07 C0-58 3.600 18-MAY-07 FE-59 8.700 18-MAY-07 CO-60 3.000 18-MAY-07 ZN-65 4.900 18-MAY-07 ZR-NB-95 5.200 18-MAY-07 CS-134 5.400 18-MAY-07 CS-137 4.300 18-MAY-07 BA-LA-140 5.300 18-MAY-07 H-3 140.000 18-MAY-07 1-131 (CHEM) 0.255 09-AUG-07 MN-54 4.300 09-AUG-07 CO-58 5.900 09-AUG-07 FE-59 3.900 09-AUG-07 CO-60 5.100 09-AUG-07 ZN-65 7.100 09-AUG-07 ZR-NB-95 5.600 09-AUG-07 CS-134 6.200 09-AUG-07 CS-137 4.800 09-AUG-07 BA-LA-140 7.200 09-AUG-07 H-3 156.000 09-AUG-07 1-131 (CHEM) 0.445 15-NOV-07 MN-54 2.400 15-NOV-07 C0-58 1.700 15-NOV-07 FE-59 2.000 15-NOV-07 CO-60 2.500 15-NOV-07 ZN-65 4.400 15-NOV-07 ZR-NB-95 3.200 15-NOV-07 CS-134 2.300 15-NOV-07 CS-137 2.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

37

Exposure Pathway - Waterborne Ground Water Location C-49 15-NOV-07 BA-LA-140 3.600 15-NOV-07 H-3 178.000 15-NOV-07 1-131 (CHEM) 0.448 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

38

Exposure Pathway - Waterborne Ground Water Location F-1 Collection Nuclide *

.oncentration K

Date (pCi/L~iter) 16-FEB-07 MN-54 3.100 16-FEB-07 CO-58 3.100 16-FEB-07 FE-59 7.300 16-FEB-07 CO-60 2.100 16-FEB-07 ZN-65 5.400 16-FEB-07 ZR-NB-95 3.600 16-FEB-07 CS-134 3.100 16-FEB-07 CS-137 2.800 16-FEB-07 BA-LA-140 2.400 16-FEB-07 H-3 135.000 16-FEB-07 1-131 (CHEM) 0.342 18-MAY-07 MN-54 4.200 18-MAY-07 CO-58 3.200 18-MAY-07 FE-59 9.800 18-MAY-07 CO-60 2.900 18-MAY-07 ZN-65 4.700 18-MAY-07 ZR-NB-95 3.100 18-MAY-07 CS-134 4.900 18-MAY-07 CS-137 4.900 18-MAY-07 BA-LA-140 6.500 18-MAY-07 H-3 140.000 18-MAY-07 1-131 (CHEM) 0.314 09-AUG-07 MN-54 2.300 09-AUG-07 CO-58 1.500 09-AUG-07 FE-59 4.000 09-AUG-07 CO-60 2.900 09-AUG-07 ZN-65 1.800 09-AUG-07 ZR-NB-95 1.700 09-AUG-07 CS-134 2.100 09-AUG-07 CS-137 2.900 09-AUG-07 BA-LA-140 1.700 09-AUG-07 H-3 156.000 09-AUG-07 1-131 (CHEM) 0.268 15-NOV-07 MN-54 2.500 15-NOV-07 CO-58 6.400 15-NOV-07 FE-59 5.300 15-NOV-07 CO-60 4.900 15-NOV-07 ZN-65 6.500 15-NOV-07 ZR-NB-95 4.600 15-NOV-07 CS-134 4.500 15-NOV-07 CS-137 5.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 39

Exposure Pathway - Waterborne Ground Water Location F-1 15-NOV-07 BA-LA-140 9.200 15-NOV-07 H-3 178.000 15-NOV-07 1-131 (CHEM) 0.390 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

40

Exposure Pathway - Waterborne Ground Water Location G-2 Collection -

Nuclide ~.ConcentrationDulct

~

Date (piLtr AnalysSis 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 18-MAY-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 09-AUG-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 MN-54 C0-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 C0-58 FE-59 C0-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 C0-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM) 2.800 3.000 5.200 2.300 3.700 2.800 3.800 2.300 3.200 140.000 0.273 2.200

1. 600 4.200 3.000 4.700
1. 800 1.800
2. 600 2.300 156.000 0.372 4.700 5.300 6.400 7.300 6.500 5.000 6.100 3.300 7.500 178.000 0.410 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

41

Exposure Pathway - Waterborne Ground Water Location J-1 Date (pCi/Liter)~

16-FEB-07 MN-54 1.800 16-FEB-07 CO-58 2.000 16-FEB-07 FE-59 4.000 16-FEB-07 CO-60 2.800 16-FEB-07 ZN-65 5.400 16-FEB-07 ZR-NB-95 2.500 16-FEB-07 CS-134 3.500 16-FEB-07 CS-137 4.100 16-FEB-07 BA-LA-140 4.700 16-FEB-07 H-3 135.000 16-FEB-07 1-131 (CHEM) 0.345 17-MAY-07 MN-54 2.100 17-MAY-07 CO-58 3.900 17-MAY-07 FE-59 5.400 17-MAY-07 CO-60 3.100 17-MAY-07 ZN-65 6.000 17-MAY-07 ZR-NB-95 3.500 17-MAY-07 CS-134 2.800 17-MAY-07 CS-137 3.700 17-MAY-07 BA-LA-140 3.000 17-MAY-07 H-3 140.000 17-MAY-07 1-131 (CHEM) 0.331 07-AUG-07 MN-54 4.300 07-AUG-07 CO-58 3.600 07-AUG-07 FE-59 7.000 07-AUG-07 CO-60 1.700 07-AUG-07 ZN-65 7.600 07-AUG-07 ZR-NB-95 2.100 07-AUG-07 CS-134 3.900 07-AUG-07 CS-137 3.700 07-AUG-07 BA-LA-140 2.700 07-AUG-07 H-3 156.000 07-AUG-07 1-131 (CHEM) 0.413 14-NOV-07 MN-54 3.000 14-NOV-07 CO-58 2.400 14-NOV-07 FE-59 3.600 14-NOV-07 CO-60 2.800 14-NOV-07 ZN-65 6.200 14-NOV-07 ZR-NB-95 4.300 14-NOV-07 CS-134 3.700 14-NOV-07 CS-137 2.100 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

42

Exposure Pathway - Waterborne Ground Water Location J-1 14-NOV-07 BA-LA-140 4.700 14-NOV-07 H-3 178.000 14-NOV-07 1-131 (CHEM) 0.404 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

43

Exposure Pathway - Waterborne Ground Water Location J-2 Collection

~

Nuclide Concentration

~

Duplicater, Date

(pCiiLiter)

Analysis 16-FEB-07 MN-54 2.400 Duplicate 16-FEB-07 MN-54 2.900 16-FEB-07 CO-58 2.800 Duplicate 16-FEB-07 CO-58 2.800 16-FEB-07 FE-59 3.400 Duplicate 16-FEB-07 FE-59 4.500 16-FEB-07 CO-60 2.800 Duplicate 16-FEB-07 CO-60 2.000 16-FEB-07 ZN-65 7.000 Duplicate 16-FEB-07 ZN-65 5.300 16-FEB-07 ZR-NB-95 3.800 Duplicate 16-FEB-07 ZR-NB-95 3.500 16-FEB-07 CS-134 4.000 Duplicate 16-FEB-07 CS-134 2.200 16-FEB-07 CS-137 3.600 Duplicate 16-FEB-07 CS-137 3.600 16-FEB-07 BA-LA-140 1.800 Duplicate 16-FEB-07 BA-LA-140 3.100 16-FEB-07 H-3 135.000 Duplicate 16-FEB-07 H-3 135.000 16-FEB-07 1-131 (CHEM) 0.585 Duplicate 16-FEB-07 1-131 (CHEM) 0.483 18-MAY-07 MN-54 5.700 18-MAY-07 C0-58 4.400 18-MAY-07 FE-59 5.000 18-MAY-07 CO-60 4.500 18-MAY-07 ZN-65 9.100 18-MAY-07 ZR-NB-95 3.500 18-MAY-07 CS-134 6.000 18-MAY-07 CS-137 5.300 18-MAY-07 BA-LA-140 5.900 18-MAY-07 H-3 140.000 18-MAY-07 1-131 (CHEM) 0.237 09-AUG-07 MN-54 4.400 09-AUG-07 CO-58 3.500 09-AUG-07 FE-59 6.000 09-AUG-07 CO-60 4.300 09-AUG-07 ZN-65 5.300 09-AUG-07 ZR-NB-95 3.500 09-AUG-07 CS-134 2.700 09-AUG-07 CS-137 6.400 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

44

Exposure Pathway - Waterborne Ground Water Location J-2 09-AUG-07 09-AUG-07 09-AUG-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

K K

K K

K K

K K

K K

K K

K K

7.200 156. 000 0.364 4.000 2.300 4.500

2. 600 3.-500 4.000 3.900 4.200 5.800 178.000 0.370 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

45

Exposure Pathway - Waterborne Ground Water Location L-49 Collection Nuclide Concent ratio n Duplicate Dae(pCi/Liter)

Arialysis 23-FEB-07 MN-54 4.700 23-FEB-07 CO-58 4.800 23-FEB-07 FE-59 7.700 23-FEB-07 CO-60 2.800 23-FEB-07 ZN-65 9.200 23-FEB-07 ZR-NB-95 4.700 23-FEB-07 CS-134 5.500 23-FEB-07 CS-137 5.300 23-FEB-07 BA-LA-140 2.900 23-FEB-07 H-3 188.000 23-FEB-07 1-131 (CHEM) 0.353 18-MAY-07 MN-54 1.600 Duplicate 18-MAY-07 MN-54 2.400 18-MAY-07 CO-58 3.000 Duplicate 18-MAY-07 CO-58 3.100 18-MAY-07 FE-59 6.100 Duplicate 18-MAY-07 FE-59 8.900 18-MAY-07 CO-60 2.200 Duplicate 18-MAY-07 CO-60 2.800 18-MAY-07 ZN-65 4.400 Duplicate 18-MAY-07 ZN-65 5.400 18-MAY-07 ZR-NB-95 2.600 Duplicate 18-MAY-07 ZR-NB-95 2.700 18-MAY-07 CS-134 2.900 Duplicate 18-MAY-07 CS-134 4.000 18-MAY-07 CS-137 3.100 Duplicate 18-MAY-07 CS-137 4.600 18-MAY-07 BA-LA-140 2.700 Duplicate 18-MAY-07 BA-LA-140 6.300 18-MAY-07 H-3 140.000 Duplicate 18-MAY-07 H-3 140.000 18-MAY-07 1-131 (CHEM) 0.390 Duplicate 18-MAY-07 1-131 (CHEM) 0.479 09-AUG-07 MN-54 3.000 09-AUG-07 CO-58 1.800 09-AUG-07 FE-59 7.800 09-AUG-07 CO-60 2.100 09-AUG-07 ZN-65 2.500 09-AUG-07 ZR-NB-95 4.200 09-AUG-07 CS-134 3.200 09-AUG-07 CS-137 4.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

46

Exposure Pathway - Waterborne Ground Water Location L-49 09-AUG-07 09-AUG-07 09-AUG-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 15-NOV-07 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

K K

K K

K K

4. 600 156. 000 0.386 3.500
2. 600 6.800 1.300 4.400
3. 000 1.800 1.800 1.900 178.000 0.412 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

47

Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection i

Concentration Date (p jlLiter 07-FEB-07 MN-54 2.300 07-FEB-07 CO-58 2.500 07-FEB-07 FE-59 2.200 07-FEB-07 CO-60 1.700 07-FEB-07 ZN-65 1.700 07-FEB-07 ZR-NB-95 1.600 07-FEB-07 CS-134 2.400 07-FEB-07 CS-137 2.500 07-FEB-07 BA-LA-140 2.400 07-FEB-07 GROSS BETA 2.943+/-

0. 696 07-FEB-07 1-131 (CHEM) 0.445 07-MAR-07 MN-54 2.700 07-MAR-07 CO-58 2.600 07-MAR-07 FE-59 4.200 07-MAR-07 CO-60 3.400 07-MAR-07 ZN-65 5.500 07-MAR-07 ZR-NB-95 4.000 07-MAR-07 CS-134 2.500 07-MAR-07 CS-137 3.000 07-MAR-07 BA-LA-140 2.000 07-MAR-07 GROSS BETA 2.881+/-

0.662 07-MAR-07 1-131 (CHEM) 0.397 04-APR-07 MN-54 2.300 04-APR-07 CO-58 1.200 04-APR-07 FE-59 5.000 04-APR-07 CO-60 2.000 04-APR-07 ZN-65 4.600 04-APR-07 ZR-NB-95 3.700 04-APR-07 CS-134 3.500 04-APR-07 CS-137 2.000 04-APR-07 BA-LA-140 1.700 04-APR-07 GROSS BETA 2.848t/-

0.393 04-APR-07 1-131 (CHEM) 0.358 02-MAY-07 MN-54 2.200 02-MAY-07 CO-58 1.700 02-MAY-07 FE-59 2.500 02-MAY-07 CO-60 1.700 02-MAY-07 ZN-65 4.600 02-MAY-07 ZR-NB-95 3.100 02-MAY-07 CS-134 2.700 02-MAY-07 CS-137 3.700 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

48

Exposure Pathway - Waterborne Drinking Water Location BW-15 Colecio Nuclide ConcentrationDulct Date (pCilLiter)

Anlyisat 02-MAY-07 BA-LA-140 2.900 02-MAY-07 GROSS BETA 2.659+/-

0.665 02-MAY-07 1-131 (CHEM) 0.438 06-JUN-07 MN-54 3.500 06-JUN-07 CO-58 3.400 06-JUN-07 FE-59 6.800 06-JUN-07 CO-60 3.700 06-JUN-07 ZN-65 5.200 06-JUN-07 ZR-NB-95 3.600 06-JUN-07 CS-134 3.400 06-JUN-07 CS-137 3.100 06-JUN-07 BA-LA-140 2.800 06-JUN-07 GROSS BETA 3.107+/-

0.688 06-JUN-07 1-131 (CHEM) 0.342 03-JUL-07 MN-54 2.200 03-JUL-07 CO-58 3.100 03-JUL-07 FE-59 3.500 03-JUL-07 CO-60 1.800 03-JUL-07 ZN-65 2.200 03-JUL-07 ZR-NB-95 4.100 03-JUL-07 CS-134 2.300 03-JUL-07 CS-137 3.400 03-JUL-07 BA-LA-140 1.400 03-JUL-07 GROSS BETA 2.956+/-

0.500 03-JUL-07 1-131 (CHEM) 0.402 01-AUG-07 MN-54 2.700 01-AUG-07 CO-58 1.800 01-AUG-07 FE-59 4.200 01-AUG-07 CO-60 3.100 01-AUG-07 ZN-65 1.600 01-AUG-07 ZR-NB-95 1.800 01-AUG-07 CS-134 3.300 01-AUG-07 CS-137 3.000 01-AUG-07 BA-LA-140 2.300 01-AUG-07 GROSS BETA 3.106+/-

1.051 01-AUG-07 1-131 (CHEM) 0.216 06-SEP-07 MN-54 5.100 06-SEP-07 CO-58 4.500 06-SEP-07 FE-59 9.000 06-SEP-07 CO-60 2.800 06-SEP-07 ZN-65 4.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

49

Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection CNncltrtio (pCilLiter) j Duplicate

~Analysis 06-S 06-S 06-S 06-S 06-S 06-S 03-0 03-0 03-0 03-0 03-C 03-C 03-C 03-0 03-C 03-C 03-C 01-N 01-N 01-N 01-N 01-N 01-N 01-N 01-N 01-N 01-N 01-N 05-D 05-D 05-D 05-D 05-D 05-D 05-D 05-D 05-C 05-C 05-D 03-J 03-J EP-07 ZR-NB-95 EP-07 CS-134 EP-07 CS-137 EP-07 BA-LA-140

.EP-07 GROSS BETA 2.355+/

EP-07 1-131 (CHEM)

)CT-07 MN-54

)CT-07 CO-58

)CT-07 FE-59

)CT-07 CO-60

)CT-07 ZN-65 CT-07 ZR-NB-95 CT-07 CS-134

)CT-07 CS-137

)CT-07 BA-LA-140

)CT-07 GROSS BETA 3.604+/-

CT-07 1-131 (CHEM)

OV-07 MN-54 OV-07 CO-58 OV-07 FE-59

[OV-07 CO-60 OV-07 ZN-65 OV-07 ZR-NB-95 OV-07 CS-134 OV-07 CS-137 OV-07 BA-LA-140 OV-07 GROSS BETA 4.278+/-

OV-07 1-131 (CHEM)

'EC-07 CO-58

'EC-07 FE-59

'EC-07 CO-60

'EC-07 ZN-65

  • EC-07 ZR-NB-95

'EC-07 1-131

'EC-07 CS-134

'EC-07 CS-137 EC-07 BA-LA-140 EC-07 GROSS BETA 2.798+/-

AN-08 MN-54 AN-08 CO-58 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station 3.100 4.100 4.000 7.300

0. 634 0.460 4. 900 4.300
6. 600 3.800 4.000 4.200 4.300
2. 600 6.800 0.725 0.220 5.000 3.700 7.200 3.100 8.700 3.600
4. 600 4.800 6.800 0.773 0.357 2.300
1. 900 4.100 2.800 5.100 2.500 0.431 2.400 3.400
3. 900 0.683 2.200 1.800 Page C - 50

Exposure Pathway - Waterborne Drinking Water Location BW-15 03-JAN-08 03-JAN-08 03-JAN-08 03-JAN-08 03-JAN-08 03-JAN-08 03-JAN-08 03-JAN-08 03-JAN-08 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM) 6.500 3.100 4.500 2.900 3.200 2.100 4.300 2.880+/-

0.657 0.451 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 51

Exposure Pathway - Waterborne Drinking Water Location 10-DW Collection~*

Nuclide Concentration Date (pCi/Liter)4 07-FEB-07 MN-54 2.300 07-FEB-07 CO-58 2.200 07-FEB-07 FE-59 3.300 07-FEB-07 CO-60 1.600 07-FEB-07 ZN-65 3.600 07-FEB-07 ZR-NB-95 2.600 07-FEB-07 CS-134 2.900 07-FEB-07 CS-137 3.100 07-FEB-07 BA-LA-140 2.200 07-FEB-07 GROSS BETA 3.404+/-

0.756 07-FEB-07 1-131 (CHEM) 0.471 07-MAR-07 MN-54 1.600 07-MAR-07 CO-58 3.100 07-MAR-07 FE-59 4.500 07-MAR-07 CO-60 1.400 07-MAR-07 ZN-65 3.700 07-MAR-07 ZR-NB-95 2.400 07-MAR-07 CS-134 2.900 07-MAR-07 CS-137 3.500 07-MAR-07 BA-LA-140 2.800 07-MAR-07 GROSS BETA 2.934+/-

0.673 07-MAR-07 1-131 (CHEM) 0.433 04-APR-07 MN-54 3.100 04-APR-07 CO-58 2.500 04-APR-07 FE-59 4.300 04-APR-07 CO-60 1.200 04-APR-07 ZN-65 4.300 04-APR-07 ZR-NB-95 3.600 04-APR-07 CS-134 2.400 04-APR-07 CS-137 2.800 04-APR-07 BA-LA-140 3.500 04-APR-07 GROSS BETA 2.939+/-

0.399 04-APR-07 1-131 (CHEM) 0.370 02-MAY-07 MN-54 2.300 02-MAY-07 CO-58 1.600 02-MAY-07 FE-59 6.000 02-MAY-07 CO-60 2.500 02-MAY-07 ZN-65 3.000 02-MAY-07 ZR-NB-95 3.200 02-MAY-07 CS-134 3.500 02-MAY-07 CS-137 2.600 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 52

Exposure Pathway - Waterborne Drinking Water Location 10-DW Collection Nuclide Concentration Date(pCilLiter)'

02-MAY-07 BA-LA-140 4.400 02-MAY-07 GROSS BETA 2.333+/-

0.626 02-MAY-07 1-131 (CHEM) 0.437 06-JUN-07 MN-54 3.100 06-JUN-07 CO-58 3.100 06-JUN-07 FE-59 7.100 06-JUN-07 CO-60 3.500 06-JUN-07 ZN-65 2.000 06-JUN-07 ZR-NB-95 3.200 06-JUN-07 CS-134 3.500 06-JUN-07 CS-137 2.600 06-JUN-07 BA-LA-140 5.700 06-JUN-07 GROSS BETA 3.612+/-

0.747 06-JUN-07 1-131 (CHEM) 0.368 03-JUL-07 MN-54 2.700 03-JUL-07 CO-58 1.600 03-JUL-07 FE-59 4.600 03-JUL-07 CO-60 2.500 03-JUL-07 ZN-65 5.500 03-JUL-07 ZR-NB-95 3.700 03-JUL-07 CS-134 3.200 03-JUL-07 CS-137 3.100 03-JUL-07 BA-LA-140 2.400 03-JUL-07 GROSS BETA 2.956+/-

0.525 03-JUL-07 1-131 (CHEM) 0.407 01-AUG-07 MN-54 1.500 01-AUG-07 CO-58 3.000 01-AUG-07 FE-59 5.400 01-AUG-07 CO-60 2.200 01-AUG-07 ZN-65 2.600 01-AUG-07 ZR-NB-95 3.500 01-AUG-07 CS-134 3.200 01-AUG-07 CS-137 3.400 01-AUG-07 BA-LA-140 2.200 01-AUG-07 GROSS BETA 2.908+/-

0. 989 01-AUG-07 1-131 (CHEM) 0.224 06-SEP-07 MN-54 2.600 06-SEP-07 CO-58 3.000 06-SEP-07 FE-59 3.800 06-SEP-07 CO-60 4.100 06-SEP-07 ZN-65 4.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

53

Exposure Pathway - Waterborne Drinking Water Location 10-DW ColcinNuclide

~

Concentration 06-SEP-07 ZR-NB-95 4.700 06-SEP-07 CS-134 4.100 06-SEP-07 CS-137 3.500 06-SEP-07 BA-LA-140 7.800 06-SEP-07 GROSS BETA 3.081+/-

0.703 06-SEP-07 1-131 (CHEM) 0.632 03-OCT-07 MN-54 4.100 03-OCT-07 CO-58 3.000 03-OCT-07 FE-59 7.100 03-OCT-07 CO-60 4.500 03-OCT-07 ZN-65 4.000 03-OCT-07 ZR-NB-95 5.400 03-OCT-07 CS-134 3.300 03-OCT-07 CS-137 3.100 03-OCT-07 BA-LA-140 8.100 03-OCT-07 GROSS BETA 4.378+/-

0.791 03-OCT-07 1-131 (CHEM) 0.277 01-NOV-07 MN-54 2.800 01-NOV-07 CO-58 3.100 01-NOV-07 FE-59 4.600 01-NOV-07 CO-60 4.300 01-NOV-07 ZN-65 3.600 01-NOV-07 ZR-NB-95 4.000 01-NOV-07 CS-134 2.400 01-NOV-07 CS-137 5.300 01-NOV-07 BA-LA-140 6.500 01-NOV-07 GROSS BETA 3.839+/-

0.765 01-NOV-07 1-131 (CHEM) 0.450 05-DEC-07 MN-54 1.900 05-DEC-07 CO-58 1.800 05-DEC-07 FE-59 3.900 05-DEC-07 CO-60 1.100 05-DEC-07 ZN-65 4.000 05-DEC-07 ZR-NB-95 3.500 05-DEC-07 1-131 0.445 05-DEC-07 CS-134 2.600 05-DEC-07 CS-137 3.800 05-DEC-07 BA-LA-140 1.800 05-DEC-07 GROSS BETA 3.143+/-

0.696 03-JAN-08 MN-54 4.800 03-JAN-08 CO-58 4.500 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 54

Exposure Pathway - Waterborne Drinking Water Location IO-DW 03-JAN-08 FE-59 6.100 03-JAN-08 CO-60 2.600 03-JAN-08 ZN-65 6.000 03-JAN-08 ZR-NB-95 5.500 03-JAN-08 CS-134 3.400 03-JAN-08 CS-137 6.300 03-JAN-08 BA-LA-140 6.900 03-JAN-08 GROSS BETA 2.743+/-

0.676 03-JAN-08 1-131 (CHEM) 0.302 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

55

Exposure Pathway - Waterborne Drinking Water Quarterly Tritium Analysis Location BW-15 04-APR-07 H-3 186.000 04-APR-07 H-3 186.000 Duplicate 03-JUL-07 H-3 176.000 03-OCT-07 H-3 145.000 03-JAN-08 H-3 182.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

56

Exposure Pathway - Waterborne Drinking Water Quarterly Tritium Analysis Location IO-DW 04-APR-07 H-3 186.000 03-JUL-07 H-3 176.000 03-OCT-07 H-3 187.000 03-JAN-08 H-3 182.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

57

Exposure Pathway - Waterborne Shoreline Sediment Location BBB 21-MAY-07 21-MAY-07 2 1-MAY-07 2 1-MAY-07 2 1-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 30-OCT-07 30-OCT-07 30-OCT-07 30-OCT-07 30-OCT-07 30-OCT-07 30-OCT-07 30-OCT-07 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 10851. 000 +/-

12049.000+/-

901.200 35.700 33.100 59.200 27.200 92.700 53.400 31.200 646. 000 22.400 16.900 67.500 8.100 40.300 23.100 13.500 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

58

Exposure Pathway - Waterborne Shoreline Sediment Location DC 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 26-OCT-07 26-OCT-07 26-OCT-07 26-OCT-07 26-OCT-07 26-OCT-07 26-OCT-07 26-OCT-07 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 11059.000+!-

658.700 29.200 23.800 66.500 13.600 34.300 15.000 18.200 666.600 22.900

30. 600 64.600 9.600 41.800 19.700 23.400 11518. 000+/-

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

59

Exposure Pathway - Waterborne Shoreline Sediment Location JRR Collec tion

,Nuclide~Vf 2

Date 07-JUN-07 K-40 07-JUN-07 MN-54 07-JUN-07 CO-58 07-JUN-07 FE-59 07-JUN-07 CO-60 07-JUN-07 ZN-65 07-JUN-07 CS-134 07-JUN-07 CS-137 09-NOV-07 K-40 09-NOV-07 MN-54 09-NOV-07 CO-58 09-NOV-07 FE-59 09-NOV-07 CO-60 09-NOV-07 ZN-65 09-NOV-07 CS-134 09-NOV-07 CS-137 G~iam'aS pec~r um rn

~

Concentration~

Duplicate~

(pCi/Kg Dry)

~

Analyjsis, 12087.000+/-

108.200 +/-

11685. 000 +/-

915.400 26.600

33. 100 72.100 29.300 61.600 46.900 43.300 632. 800 24.400
18. 900
54. 600 19.900 48.200 19.300 19.300 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

60

Exposure Pathway - Waterborne Shoreline Sediment Location SC 27-JUN-07 K-40 12250.000+/-

823.400 27-JUN-07 MN-54 35.500 27-JUN-07 CO-58 40.700 27-JUN-07 FE-59 93.400 27-JUN-07 CO-60 11.500 27-JUN-07 ZN-65 105.100 27-JUN-07 CS-134 53.500 27-JUN-07 CS-137 33.600 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

61

Exposure Pathway - Ingestion Fish Location CCL 11-MAY-07 COMMON CARP K-40 2741.800+/-

370.800 11-MAY-07 COMMON CARP MN-54 9.700 11-MAY-07 COMMON CARP CO-58 8.300 11-MAY-07 COMMON CARP FE-59 17.300 11-MAY-07 COMMON CARP CO-60 9.200 11-MAY-07 COMMON CARP ZN-65 39.000 11-MAY-07 COMMON CARP CS-134 11.200 11-MAY-07 COMMON CARP CS-137 12.300 11-MAY-07 COMMON CARP H-3 7266.000+/-

208.000 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 11-MAY-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH WHITE BASS WHITE BASS WHITE BASS WHITE BASS WHITE BASS WHITE BASS WHITE BASS WHITE BASS WHITE BASS SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH BASS BASS BASS BASS BASS BASS BASS BASS BASS BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 3428.800+/-

472.300 15.900 13.400 27.500 16.300 39.600 22.100 22.000 6022.000+/-

193.000 2759.600+/-

416.100 13.100 12.200 24.200 15.000 26.300 17.700 11.300 5505.000+/-

178.000 3286.500+/-

474.000 20.000 8.600 21.800 15.000 20.700 21.200 16.300 5917.000+/-

206.000 3027.700+/-

597.800 13.900 17.800 25.200 16.900 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

62

Exposure Pathway - Ingestion Fish Location CCL Collection, Sample Date' Description Gammba Spectrumi & H-3 p

Nucli~de Concentration

'Duplicate (pC~i/K~g Wet)

Analysis 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 SMALLMOUTH BUFFALO SMALLMOUTH BUFFALO SMALLMOUTH BUFFALO SMALLMOUTH BUFFALO WIPER WIPER WIPER WIPER WIPER WIPER WIPER WIPER WIPER CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 31.200

15. 400 23.800 6521.000+/-

209.000 3077.800+/-

521.700 28.800 11.400 38.100 20.100 20.300 19.500 15.700 6848.000+/-

214.000 2868.500+/-

465.800

16. 600 8.500 30.600 9.200 23.400 16.900 17.400 7194.000+/-

228.000 2539.300+/-

353.000 9.300 11.900 33.800 4.600 21.400 7.400 8.200 6756.000+/-

216.000 2302.900+/-

340.700 9.400 10.100 19.200 7.200 8.800 8.400 14.400 5788.000+/-

199.000 3158.900+/-

482.500 FLATHEAD FLATHEAD FLATHEAD FLATHEAD FLATHEAD FLATHEAD FLATHEAD FLATHEAD FLATHEAD WALLEYE CATFISH CATFISH CATFISH CATFISH CATFISH CATFISH CATFISH CATFISH CATFISH Duplicate 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

63

Exposure Pathway - Ingestion Fish Location CCL

Collecti*n Sample 3/4 Date
~,

Description Nuclide

'Gamma Spectrum & H-3 Concentration

'Duplicate (pCiIKg Wet),

Analysis~~

24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 24-OCT-07 WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WALLEYE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 CS-134 CS-134 CS-137 CS-137 H-3 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 3134.300+/-

K K

K K

K K

K K

K K

K K

7235. 000+/-/-

6828. 000+/-

2660. 500+/-

K K

K 6582.000+!-

514.300

20. 500 15.900 19.800 10.700 32.000 27.000 18.500
10. 500 49.000 26.100 11.100 8.300 19.300 11.700 223.000 217.000 499.000 17.000 6.100 24.500 15.500 27.300 13.000 15.100 208.000 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

64

Exposure Pathway - Ingestion Fish Location JRR Gamma Spectrum & H-3 NulceConcentration.

Duplicate (piKgWt A~nalysis 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 01-JUN-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP LARGEMOUTH BASS LARGEMOUTH BASS LARGEMOUTH BASS LARGEMOUTH BASS LARGEMOUTH BASS LARGEMOUTH BASS LARGEMOUTH BASS LARGEMOUTH BASS LARGEMOUTH BASS CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH CHANNEL CATFISH COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 2997. 000+/-

K K

K K

K K

3681.500+!-

K K

K K

K K

K 3511. 600+/-/-

K K

K K

K 3077. 000+/-

K K

K K

K 2889.000+/-!-

K K

381.300 14.800 12.600 26.400 15.200 13.700 10.800 11.600 140.000 449.600 10.900 11.600 18.100 20.000 17.800 9.800 12.500 134.000 536.000 11.500 12.600 33.200 24.000 24.000 17.800 15.900 140.000 459.900 18.100 22.000 60.800 16.200 20.800 15.300 12.800 132.000 311.000

5. 600
12. 900 35.500 13.300 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

65

Exposure Pathway - Ingestion Fish Location JRR 09-NOV-07 COMMON CARP ZN-65 14.600 09-NOV-07 COMMON CARP CS-134 10.500 09-NOV-07 COMMON CARP CS-137 13.300 09-NOV-07 COMMON CARP H-3 153.000 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH SMALLMOUTH BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO BUFFALO K-.40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 H-3 2890.400+/-

319.300 11.600 18.300 29.900 7.400 15.900 9.800 13.400 129.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 66

Exposure Pathway - Ingestion Food/Garden Location C-2 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES BE-7 769.700 +/-

280.000 K-40 4825.600 +/-

559.000 MN-54 20.200 CO-58 15.000 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 23.000 28.500 22.400 22.300 24.400 14.200 16.400 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

67

Exposure Pathway - Ingestion Food/Garden Location D-2 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 17-MAY-07 13-JUN-07 13-JUN-07 13-JUN-07 13-JUN-07 13-JUN-07 13-JUN-07 13-JUN-07 13-JUN-07 HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 C0-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 C0-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 C0-58 FE-59 CO-60 ZN-65 ZR-NB-95 752.800 +1-434.500 8653.100 +/-

958.200 31.700 32.000

42. 900 38.700 54.300 46.100 47.200
40. 900 33.500 200.200 4595.700 +/-

428.400 16.200 14.000 34.500 17.100 33.100 15.400 33.800 15.100 11.000 277. 900 3900.000 +/-

482.200 12.700 9.400 16.800 15.700 31.200 16.800 40.100 16.000 20.400 973.800 +/-

252.800 5535.300 +/-

601.500 19.200 10.500 22.600 12.500 32.500 20.300 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

68

Exposure Pathway - Ingestion Food/Garden Location D-2 13-JUN-07 13-JUN-07 13-JUN-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 12-SEP-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 25.000 16.500 15.300 192.400 4460.800 +/-

502.300 17.400 11.700 29.100 16.200 24.900 18.500 24.200 15.500 13.500 472.300 +/-

209.600 6871.600 + /-

591.700 19.500 17.500 20.100 15.900 28.300 16.100 18.400 12.300 17.700 932.200 +/-

240.400 6336.000 +/-

694.200 25.800 14.400 30.200 24.200 42.200 21.900 30.700 18.600 27.900 755.800 +/-

171.100 5812.700 +

5-518.800 16.400 13.200 20.200 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

69

Exposure Pathway - Ingestion Food/Garden Location D-2 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO760 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 567.400 +/-

5534.200 +/-

18.400 32.100 22.800 25.300 12.300 18.500 153.300 409.300 11.800 11.800 28.400 12.100 30.000 18.200 34.000 15.300 11.500 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

70

Exposure Pathway - Ingestion Food/Garden Location N-1 Gam*...ma Spectrum.

Collection Sample NulieConc~entration Duplicate Date Description (pCiIKg Wet)

A~nalysiis 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 28-MAR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 25-APR-07 17-MAY-07 17-MAY-07 17-MAY-07 HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 C0-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 C0-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 155.200 2660.000 +/-

378.300 9.700 14.000 31.200 10.900 25.300 8.000 13.300 16.200 12.500 147.500 3063.300 +/-

332.800 9.500 Y22.000 14.800 11.500 16.500 15.300 19.200 10.500 12.000 401.300 +/-

193.000 3517.300 +/-

398.500 7.400 13.300 29.500 17.200 23.200 9.000 26.600 12.300 19.400 858.100 +/-

229.800 2787.300 +/-

439.700 20.900 16.200 22.800 11.600 37.600 11.800 17-MAY-07 HORSERADISH LEAVES 17-MAY-07 HORSERADISH LEAVES 17-MAY-07 HORSERADISH LEAVES 17-MAY-07 17-MAY-07 17-MAY-07 HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES 17-MAY-07 HORSERADISH LEAVES 17-MAY-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 13-JUN-07 HORSERADISH LEAVES 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 71

Exposure Pathway - Ingestion Food/Garden Location N-1 13-JUN-07 13-JUN-07 13-JUN-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 22-AUG-07 22-AUG-07 22-AUG-07

'22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES 1-131 CS-134 CS-137 BE-7 BE-7 K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 3119.800 +

3402.100 +

365.300 +

3373.000 +

r.,g wi 32.700 16.400 19.300 207.500 179.800

/-

462.100

/-

460.800 14.100 1.3.800 9.400 16.600 40.700 40.800 11.600 18.900 33.300 43.300 15.000 16.200 26.400 29.700 20.000 14.600 16.200 13.600

-/-

200.800 I/-

433.000 14.000 13.900 25.100 9.800 25.400 15.800 20.800 11.300 11.700 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT LEAVES LEAVES LEAVES LEAVES LEAVES 1610.000 +/-

8183.200 +/-

452.800 702.000 18.000 15.300 39.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station

-Page C -

72

Exposure Pathway - Ingestion Food/Garden Location N-1 A'

Gamma Spectrum Collection )'

Sample' Nuclide Concentraion' Duplicate Date ~.

Descriptio~n (pCiIKg Wet)

Analysis 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 PEPPER PEPPER PEPPER PEPPER PEPPER PEPPER PLANT PLANT PLANT PLANT PLANT PLANT HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH HORSEREDISH LEAVES LEAVES

  • LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 14.500 46.800 27.600 45.800 25.800 23.900 143.400 2908.100 +/-

310.000 7.300 11.400 29.200 6.200 13.000 9.100 24.900 12.400 11.700 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

73

Exposure Pathway - Ingestion Food/Garden Location Q-6 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 11-JUL-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 22-AUG-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 19-OCT-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 20-NOV-07 RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT BUTTERNUT SQUASH SQUASH SQUASH SQUASH SQUASH SQUASH SQUASH SQUASH SQUASH SQUASH SQUASH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 282.700 +/-

2495.700 +/-

K 2727.400 +/-

6406.400 +/-

K 157.200 381.600 11.700 12.200

9. 600 13.400 18.400 9.100 25.800
16. 600 14.700 352.100 646.200 18.300 11.700 26.400
18. 900 22.800 9.800 22.000 19.500 16.500 288.400 653. 800
13. 600 11.300 26.400
20. 600
60. 000 25.400 25.100
17. 600 23.500 88.900 336.400 8.900 9.200 24.700 13.900 21.400 16.400 PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT PEPPER PLANT KALE KALE KALE KALE KALE KALE KALE KALE LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES 1381.700 +/-

8289.200 +/-

K K

K K

3744.500 +/-

K K

K K

K 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

74

Exposure Pathway - Ingestion Food/Garden Location Q-6 20-NOV-07 KALE 1-131 8.100 20-NOV-07 KALE CS-134 10.500 20-NOV-07 KALE CS-137 8.100 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

75

Exposure Pathway - Ingestion Feed and Forage Location NR-D1 iii ecm*a it Collection Sample Nucide

~

Concentration D~uplicate

~Date Description (pCiIKg Wet)

Analysis 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 10-OCT-07 IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED CORN CORN CORN CORN CORN CORN CORN CORN CORN CORN CORN BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 1378.500 +

48.800

  • /-

305.000 5.800 3.800 10.900 7.200 15.500 6.600 9.100 6.200 7.300 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

76

Exposure Pathway - Ingestion Feed and Forage Location NR-D2 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 24-SEP-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 01-NOV-07 IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED IRRIGATED CORN CORN CORN CORN CORN CORN CORN CORN CORN CORN CORN SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 3390.300 +-17 K

K K

14596.000 +/-

K K

K

63. 600 229.900 6.900 7.300 15.500 6.000 8.500 6.500 25.200 6.000 5.800 115.800 599.400 6.200 12.300 26.300 14.500 24.900 11.600 17.400 5.100 10.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

77

Exposure Pathway - Ingestion Feed and Forage Location NR-U1 Co~~~l~~ection"mm Nudlldc

~

ocnrumot.

Duic Clleto Sample Nuld.

Gamcnrnatin Spectrum>

Dpate Description (pCi/Kg We)Analysis 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 17-SEP-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07.

04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 04-OCT-07 NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED NON-IRRIGATED CORN CORN CORN CORN CORN CORN CORN CORN CORN CORN CORN SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS SOYBEANS BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 BE-7 K-40 K-40 MN-54 MN-54 c6-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 2854.600 +/-

K K

K 14813.000 +/-

15944.000 +/-

136.700 440. 900 17.800 14.600 42.300 17.300 18.500 19.200 23.900 13.000 10.700 161.800 102.400 889.300 601.000 14.000 11.900 23.400 4.300 57.400

13. 500
17. 900 20.700 75.900 31.300 21.200
7. 900
22. 600 9.400 14.800
8. 100 16.300 11.100 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

78

Exposure Pathway - Aquatic Bottom Sediment Location DC ColIecti6n INUCiiue Datei

}:

TGamma Spectrum4, Concentration

~

DUplicate (pCi/Kg Dry)

Aayi 11-MAY-07 K-40 13569.000

+/-

1124.000 11-MAY-07 MN-54 41.700 11-MAY-07 CO-58 47.700 11-MAY-07 FE-59 75.400 11-MAY-07 CO-60 107.900

+/-

62.600 11-MAY-07 ZN-65 86.700 11-MAY-07 CS-134 59.400 11-MAY-07 CS-137 179.800

+/-

37.700 26-OCT-07 K-40 12801.000

+/-

621.200 26-OCT-07 MN-54 24.600 26-OCT-07 CO-58 32.700 26-OCT-07 FE-59 48.600 26-OCT-07 CO-60 88.700

+/-

24.200 26-OCT-07 ZN-65 47.600 26-OCT-07 CS-134 20.200 26-OCT-07 CS-137 167.700 +/-

32.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 79

Exposure Pathway - Aquatic Bottom Sediment Location EEA 22-JUN-07 K-40 9920.200

+/-

786.600 22-JUN-07 MN-54 31.100 22-JUN-07 CO-58 36.100 22-JUN-07 FE-59 110.500 22-JUN-07 CO-60 26.500 22-JUN-07 ZN-65 65.000 22-JUN-07 CS-134 42.500 22-JUN-07 CS-137 28.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

80

Exposure Pathway - Aquatic Bottom Sediment Location JRR 02-AUG-07 02-AUG-07 02-AUG-07 02-AUG-07 02-AUG-07 02-AUG-07 02-AUG-07 02-AUG-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 09-NOV-07 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 14889.000

+/-

121.500

+/-

15503.000

+/-

1 K

129.300

+/-

1091.000 38.100 43.800 108.600 28.500 76.600 57.700 37.500 671.500

25. 600 21.800 56.900 17.000
53. 900 15.500 27.000 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

81

Exposure Pathway - Aquatic Bottom Sediment Location MUDS 12-JUN-07 K-40 7502.300

+/-

856.400 12-JUN-07 MN-54 41.800 12-JUN-07 C0-58 45.200 12-JUN-07 FE-59 68.300 12-JUN-07 CO-60 24.300 12-JUN-07 ZN-65 96.900 12-JUN-07 CS-134 54.500 12-JUN-07 CS-137 24.200 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

82

Exposure Pathway - Aquatic Vegetation Location EEA Collection 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 12-JUN-07 Description S PIKERU SH-SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSE MNuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 Gamma Spectrum Concentration (pCi.Kg Wet)

Duplicate Sample 1162.700 +/-

3384.600+/-

K K

K 210.300 358.600 12.800 14.300 19.700 14.300 21.400 15.200 34.600 12.600 17.400 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

83

Exposure Pathway - Aquatic Vegetation Location SC 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 27-JUN-07 CATTAILS CATTAILS CATTAILS CATTAILS CATTAILS CATTAILS CATTAILS CATTAILS CATTAILS CATTAILS CATTAILS BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 285.400+!-

2504.100 +/-

K K

K K

K 149.800 321.500 15.300 15.700 23.100 12.800 25.100 18.500 27.600 12.700 11.100 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 84

Exposure Pathway - Terrestrial Vegetation Location EEA 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 21-MAY-07 PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 739.500++/-/-

7001. 400+/

283.400 506.600 10.000 16.300 28.200 10.100 34.400 11.200 35.600 13.800 11.500 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

85

Exposure Pathway - Terrestrial Vegetation Location MUDS 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 22-JUN-07 PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE BE-7 407.500+/-

192.900 K-40 4592.700+/-

336.800 MN-54 17.200 CO-58 16.700 FE-59 24.800 CO-60 9.700 ZN-65 35.700 ZR-NB-95 11.600 1-131 49.600 CS-134 14.400 CS-137 13.100 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

86

Exposure Pathway - Terrestrial Soil Location EEA 21-MAY-07 K-40 9090.300+/-

833.100 21-MAY-07 MN-54 34.800 21-MAY-07 CO-58 38.100 21-MAY-07 FE-59 80.500 21-MAY-07 CO-60 40.700 21-MAY-07 ZN-65 99.900 21-MAY-07 CS-134 53.300 21-MAY-07 CS-137 446.200+/-

64.800 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

87

Exposure Pathway - Terrestrial Soil Location MUDS 05-JUN-07 K-40 11616.000+/-

1004.000 05-JUN-07 MN-54 44.600 05-JUN-07 CO-58 49.400 05-JUN-07 FE-59 150.700 05-JUN-07 CO-60 13.800 05-JUN-07 ZN-65 78.900 05-JUN-07 CS-134 58.000 05-JUN-07 CS-137 326.400+/-

56.500 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

88

WOLF CREEK GENERATING STATION 2007 LAND USE CENSUS REPORT Revision 1 Prepared by:

Teresa L. Rice Peer Review:

12-21-07 Date 12/26/07 Date 12/26/07 Date Dan E. Haines Approved by:

~J~7 7~4~

Robert A. Hammond 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 1

EXECUTIVE

SUMMARY

The annual Land Use Census of rural residents within five miles of the Wolf Creek Generating Station (WCGS) has been completed for 2007 in accordance with AP 07B-004, [Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program)].

No program changes are necessary regarding milk locations. Again, no milk sampling locations were identified.

Changes are not required for the Radiological Environmental Monitoring Program (REMP) broadleaf vegetation sample locations for 2008. The two broadleaf vegetation locations with the highest calculated annual average D/Q rankings are Q2.35-MILA1619 and N2.38-RRDR9.

AP 07B-004 specifies that an "alternate location may be used to provide continued monitoring".

The third-ranked garden is location C1.92-16RD1655. It should be noted that locations Q2.35-MILA1619, N2.38-RRDR9 and C1.92-16RD1655 were established sampling locations for the 2007-growing season.

The 2007 Land Use Census Report has been revised to add a trailer house residence located in Sector B. This location is the closest occupied residence in Sector B.

BACKGROUND Section 5.2, Attachment A, of the ODCM procedure (AP 07B-004), directs that "a Land Use Census shall be conducted annually during the growing season to identify the nearest (1) milk animal, (2) residence, and (3) garden of greater than 500 square feet producing broadleaf vegetation in each of the 16 meteorological sections within five miles of the WCGS site" and "the results of the Land Use Census shall be included in the Annual Radiological Environmental Operating Report."

Table 5-1, Attachment A, of the ODCM (AP 07B-004) requires that broadleaf vegetation samples be collected from 'two indicator locations with highest calculated annual average D/Q."

Table 5-1, Attachment A, of the ODCM (AP 07B-004) also requires that milk samples be collected from "three indicator locations within 5 miles of the site having the highest dose potential."

METHODOLOGY Two hundred fifteen surveys were mailed to the rural residents living within five miles of WCGS.

A follow-up survey was sent to residents who did not respond.

The survey excluded the residents of New Strawn, Burlington, and a trailer park north of Burlington. These locations were excluded due to the large number of households and the low likelihood that information gained from these residences would affect the locations chosen for REMP sampling. Drive-by information was collected for the nearest residences that did not return surveys.

The information collected was compiled and the results are identified in Tables 1-3.

Calculations were performed so that garden locations could be ranked by their respective D/Q.

These results are contained in Table 4.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 2

RESULTS NOTE: A Global Positioning System was used to verify residence distances and sectors.

As identified in Table 2, sector B experienced a change in the nearest occupied residence.

Five location changes were noted for the nearest garden producing broadleaf vegetation.

These changes are identified in Table 3.

There were no changes regarding milk sample locations. Again, no locations were identified that routinely milked animals for human consumption.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 3

TABLE 1 2007 Land Use Census Data Location of Nearest:

Sector A

B C

D E

F G

H J

K L

M N

P Q

R Residence A2.60-17TE1 520 B1.86-PLRD16XX C1.92-16RD1655 D2.03-QULA1571 E1.77-QULA1485 F1.76-14RD1730 G3.03-13RD1820 H3.09-12RD1711 J3.70-11 RD1540 K2.70-12LA1 439 L2.10-NARD 1339 M2.47-14RD11322 N1.71-NARD1441 P2.76-HW751534 Q2.35-MILA1619 R2.08-NALN11650 Milking Animals None None None None None None None None None None None None None None None None Broadleaf Garden None B4.09-18RD1739 C1.92-16RD1655 D3.00-16RD1829 None F2.44-RERD1391 G3.77-12RD1 831 H3.30-QURD1 175 J3.80-11 RD1 535 K4.10-NARD1120 L2.39-NARD1309 M3.10-13LA1 290 N2.38-RRDR9 P2.76-HW751534 Q2.35-MILA1619 None Identifiers are based upon the following protocol:

EXAMPLE: Al'.4-16RD1525 "A" = Sector A "11.4" = 1.4 miles from the reactor "16RD1525" = address 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 4

TABLE 2 SECTOR 2006 NEAREST 2007 NEAREST RESIDENCE RESIDENCE A2.60-17TE1 520 B3.53-QURD1755 C1.92-16RD1655 D2.03-QULA1571 El.77-QULA1485 F1.76-14RD1730 G3.03-13RD1820 H3.09-12RD1711 J3.70-1 1 RD1540 K2.70-12LA1 439 L2.10-NARD1339 M2.47-14RD1322 N1.71-NARD1441 P2.76-HW751534 Q2.35-MILA1619 R2.08-NALN1650 A2.60-17TE1 520 B1.86-PLRD16XX C1.92-16RD1655 D2.03-QULA1 571 El.77-QULA1485 F1.76-14RD1730 G3.03-13RD1820 H3.09-12RD1711 J3.70-1 1 RD 1540 K2.70-12LA1 439 L2.10-NARD 1339 M2.47-14RD1322 N1.71 -NARD 1441 P2.76-HW751534 Q2.35-MILA1619 R2.08-NALN1650 NOTE: Entries underlined indicate changes from the 2006 Land Use Census.

Locations are identified based upon the following protocol:

EXAMPLE: A1.4-16RD1525 First letter is based upon sector, thus "A" designates this residence is in sector A.

The number immediately following the first letter designates the distance (in miles) from the reactor.

The characters following the dash represent a unique identifier based upon location address.

The example is in sector A, 1.4 miles from the reactor, at 1525 16th Road.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 5

TABLE 3 2007 Land Use Census Milk and Garden Data SECTOR 2006 2007 2006 CLOSEST 2007 CLOSEST MILKING MILKING GARDEN GARDEN ANIMALS ANIMALS PRODUCING PRODUCING BROADLEAF BROADLEAF VEGETATION VEGETATION A

None None None None B

None None None B4.09-18RD1739 C

None None C1.92-16RD1655 C1.92-16RD1655 D

None None D3.00-16RD1829 D3.00-16RD1829 E

None None E4.40-TRRD1551 None F

None None F2.44-RERD1391 F2.44-RERD1391 G

None None G3.66-12RD1814 G3.77-12RD1831 H

None None H3.30-QURD1175 H3.30-QURD1175 J

None None J3.90-11RD1531 J3.80-11RD1535 K

None None K4.10-NARD1120 K4.10-NARD1120 L

None None L2.39-NARD1309 L2.39-NARD1309 M

None None M3.10-13LA1290 M3.10-13LA1290 N

None None N2.38-RRDR9 N2.38-RRDR9 P

None None P2.76-HW751534 P2.76-HW751534 Q

None None Q2.35-MILA1619 Q2.35-MILA1619 R

None None R2.08-NALN1650 None NOTE: Underlined entries indicate changes from the 2006 Land Use Census.

Locations are identified based upon the following protocol:

EXAMPLE: A1.4-16RD1525 First letter is based upon sector, thus "A" designates this residence is in sector A.

The number immediately following the first letter designates the distance (in miles) from the reactor.

The characters following the dash represent a unique identifier based upon location address.

The example is in sector A, 1.4 miles from the reactor, at 1525 16th Road.

2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 6

TABLE 4 Information Used for D/Q Calculations FROM LAND FROM USE AN-04-045 DIST CALC NEAR NEAR FAR FAR SECTOR D/Q

  • 1

_20%

SECTOR (MI)

(METERS)

DIST D / Q DIST D / Q CALC RANKING A

0 0

B 4.09 6585 6000 5.32E-10 7000 3.95E-10 4.52E-10 7

5.42E-10 C

1.92 3091 3000 7.26E-10 4000 4.36E-10 7.OOE-10 3

8.40E-10 D

3.00 4830 4000 3.20E-10 5000 2.18E-10 2.35E-10 13 2.82E-10 E

0 0

F 2.44 3928 3000 6.41E-10 4000 3.84E-10 4.03E-10 8

4.84E-10 G

3.77 6070 6000 3.65E-10 7000 2.71E-10 3.58E-10 11 4.30E-10 H

3.30 5313 5000 5.84E-10 6000 4.29E-10 5.35E-10 6

6.42E-10 J

3.80 6118 6000 3.72E-10 7000 2.76E-10 3.61E-10 10 4.33E-10 K

4.10 6601 6000 3.91E-10 7000 2.90E-10 3.30E-10 12 3.96E-10 L

2.39 3848 3000 9.61E-10 4000 5.77E-10 6.35E-10 4

7.62E-10 M

3.10 4991 4000 5.77E-10 5000 3.92E-10 3.94E-10 9

4.73E-10 N

2.38 3832 3000 1.09E-09 4000 6.54E-10 7.27E-10 2

8.72E-10 P

2.76 4444 4000 7.30E-10 5000 4.97E-10 6.27E-10 5

7.52E-10 Q

2.35 3784 3000 1.75E-09 4000 1.05E-09 1.20E-09 1

1.44E-09 R

0 0

I I

I I

I Originated by:

Verified by:

Date:

09-14-07 Date:

9-18-07 2007 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 7