NLS2010048, Annual Radiological Environmental Report for 2009

From kanterella
(Redirected from ML101390493)
Jump to navigation Jump to search

Annual Radiological Environmental Report for 2009
ML101390493
Person / Time
Site: Cooper Entergy icon.png
Issue date: 05/14/2010
From: Vanderkamp D
Nebraska Public Power District (NPPD)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NLS2010048
Download: ML101390493 (251)


Text

H Nebraska Public Power District "Always there when you need us" NLS2010048 May 14, 2010 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001

Subject:

Annual Radiological Environmental Report Cooper Nuclear Station, Docket No. 50-298, DPR-46

Dear Sir or Madam:

The purpose of this letter is to submit the Cooper Nuclear Station (CNS) Annual Radiological Environmental Report for the period January 1, 2009, through December 31, 2009. The enclosed report is being submitted per the requirements of Technical Specification 5.6.2 and CNS Offsite Dose Assessment Manual Section D 5.2.

Should you have any questions or require additional information, please contact me at (402) 825-2904.

Sincerely, David W. Van Der Kamp Licensing Manager

/jf Enclosure cc: Regional Administrator w/ enclosure NPG Distribution w/o enclosure USNRC - Region IV Cooper Project Manager w/ enclosure CNS Records w/ enclosure USNRC - NRR Project Directorate IV-1 Senior Resident Inspector w/ enclosure USNRC - CNS COOPER NUCLEAR STATION P.O. Box 98 / Brownville, NE 68321-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5271 www ,nppd.corn

4 ATTACHMENT 3 LIST OF REGULATORY COMMITMENTS© ATTACHMENT 3 LIST OF REGULATORY COMMITMENTS©4 Correspondence Number: NLS2010048 The following table identifies those actions committed to by Nebraska Public Power District (NPPD) in this document. Any other actions discussed in the submittal represent intended or planned actions by NPPD. They are described for information only and are not regulatory commitments. Please notify the Licensing Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.

COMMITMENT COMMITTED DATE COMMITMENT NUMBER OR OUTAGE None

4. 4 4- 4
4. 4 1* I
4. 4
4. 4 I PROCEDURE 0.42 REVISION 24 PAGE 18 OF 25

NLS2010048 Enclosure Enclosure Annual Radiological Environmental Report January 1, 2009 through December 31, 2009

NEBRASKA PUBLIC POWER DISTRICT' COOPER NUCLEAR STATION RadiologicalEnvironmentalMonitoringProgram 2009 Annual Report January1, 2009 to December 31, 2009 Prepared by Teledyne Brown Engineering 2508 Quality Lane Knoxville, TN 37931-3133

TABLE OF CONTENTS SECTION TITLE PAGE Preface .................................................................................................. 6 I. Introduction ........................................... 7 II. Sum m ary ............................................................................................ 10 III. Sam pling and A nalyses Program ...................................................... 12 IV. Summary and Discussion of 2009 Analytical Results ....................... 17 A . A irborne Particulates ........................................................................ 19 B. A irborne Iodine ............................................................................ 20 C. Fish .............................................................................................. 21 D . M ilk - Nearest Producer ............................................................. 22 E. M ilk - Othe.r Producers ............................................................... 23 F. Ground W ater ............................................................................... 24 G . River W ater ................................................................................. 25 H . Therm olum inescent Dosim eters .................................................. 26 I. Food - Broadleaf V egetation ...................................................... 27 J. Shoreline Sedim ent ...................................................................... 29 K . Errata D ata ................................................................................... 30 V. Conclusions ........................................................................................ 31 VI. Radiological Environmental Monitoring Program Summary Table - 2009 ....................................................................................... 33 V II. Com plete Data Tables ........................................................................ 39 VIII. References .......................................................................................... 99 2

TABLE OF CONTENTS (Cont)

APPENDICES APPENDIX A - 2009 Land Use Census ........................................................ A-i APPENDIX B - Summary of Interlaboratory Comparisons ......................... B-i APPENDIX C - Synopsis of Analytical Procedures ................... C-1 APPENDIX D - Detection Limits and Reporting Levels ............................. D-i APPENDIX E - REMP Sampling and Analytical Exceptions ....................... E-1 APPENDIX F - Summary of Doses to a Member of the Public Offsite ...... F-i APPENDIX G - REMP Sample Station Descriptions .................................. G-1 APPENDIX H - Annual Radiological Groundwater Protection Program (A RGPP) Report ................................................................. H -1 APPENDIX I - Non-ODAM Required Sampling, Supplementary Stations ........ I-1 LIST OF FIGURES

1. M aps of Sam pling Stations ................................................................... 15 3

TABLE OF CONTENTS (Cont)

LIST OF TRENDING GRAPHS

1. Gross Beta in Air Particulates ............................ 19
2. Iodine-131 in Charcoal Filters .............................................................. 20
3. C esium -137 in Fish ............................................................................... 21
4. Iodine-131 and Cesium-137 in Milk-Nearest Producer ..................... 22
5. Iodine-131 and Cesium-137 in Milk - Other Producers ...................... 23
6. Tritium in Ground W ater ..................................................................... 24
7. Tritium in R iver W ater .......................................................................... 25
8. Thermoluminescent Dosimetry ............................................................ 26
9. Iodine-131 and Cesium-137 in Food - Broadleaf Vegetation .............. 27
10. Cesium-134 and Cesium-137 in Shoreline Sediment ........................... 29 4

TABLE OF CONTENTS (Cont)

LIST OF TABLES I Sampling and Analyses Program .................................................... 12 VII-1 Exposure Pathway - Airborne Air Particulate & Charcoal Filters ...... 40 VII-2 Exposure Pathway - Airborne Composite Air Particulate Filters ....... 60 VII-3 Exposure Pathway - Ingestion Fish ............................................... 70 VII-4 Exposure Pathway - Ingestion Milk Nearest Producer ................... 72 VII-5 Exposure Pathway - Ingestion Milk Other Producers .................... 76 VII-6 Exposure Pathway - Ingestion Water - Ground ............................. 77 VII-7 Exposure Pathway - Ingestion Water - River ................................ 81 VII-8 Exposure Pathway - Thermoluminescent Dosimetry - TLD ...... 87 VII-9 Exposure Pathway - Ingestion Vegetation - Terrestrial, Broadleaf ....89 VII-10 Exposure Pathway- Airborne Shoreline Sediment ....................... 97 5

PREFACE This report covers the period of January 1 through December 31, 2009. Personnel of the Nebraska Public Power District made all sample collections. Analyses were performed and reports of analyses were prepared by Teledyne Brown Engineering -

Environmental Services and forwarded to Nebraska Public Power District. Environmental Thermoluminescent Dosimeter (TLD) analyses were performed and reports of analyses were prepared by Global Dosimetry Solutions.

6

SECTION I. INTRODUCTION 7

I. INTRODUCTION This report contains a complete tabulation of data collected during the period January through December 2009, for the operational Radiological Environmental Monitoring Program performed for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) by Teledyne Brown Engineering - Environmental Services.

Cooper Nuclear Station is located in Nemaha County in the southeast comer of Nebraska on the Missouri River. A portion of the site extends into Missouri. The reactor is an 830-megawatt (net electrical) boiling water reactor. Initial criticality was attained on February 21, 1974.

Radiological environmental monitoring began in 1971 before the plant became operational and has continued to the present. The program monitors radiation levels in air, terrestrial and aquatic environments. All samples are collected by NPPD personnel.

All samples are shipped for analysis to a contractor's laboratory where there exists special facilities required for measurements of extremely low levels of radioactivity. Teledyne Brown Engineering - Environmental Services has the responsibility f6r the analyses for Cooper Nuclear Station.

The United States Nuclear Regulatory Commission (USNRC) regulations (10CFR50.34a) require that nuclear power plants be designed, constructed, and operated to keep levels of radioactive material in effluents to unrestricted areas as low as is reasonably achievable (ALARA). Inplant monitoring is used to ensure that release limits are not exceeded. As a precaution against unexpected or undefined environmental processes, which might allow undue accumulation of radioactivity in the environment, a program for monitoring the plant environs is included in NPPD's CNS Offsite Dose Assessment Manual (ODAM).

8

A. Atmospheric Nuclear Tests Three atmospheric nuclear detonations in the People's Republic of China influenced program results significantly in late 1976 and in 1977. Two of these detonations occurred in late 1976 (September 26 and November 17) and one in late 1977 (September 17). As a consequence of these tests elevated activities of gross beta in air particulate filters and 1-131 in milk were observed throughout most of the United States. No atmospheric nuclear tests have been conducted since 1980, thus no short-lived fission products were detected in air particulate samples.

On April 26, 1986 the fire and explosion of Chernobyl Reactor No. 4 in the Soviet Union resulted in the release of fission products to the atmosphere and worldwide fallout.

Following the explosion, elevated levels of gross beta activities in air particulates and Iodine-131 in charcoal filters and milk samples were measured. Additionally, in 1986, Cesium-137 and the short-lived radionuclides Iodine-131, Ruthenium-106, and Cesium-134 were detected in broadleaf vegetation. Similar results occurred in other areas of the United States and the entire Northern Hemisphere.

B. Propram Objectives and Data Interpretation The objective of the monitoring program is to detect and assess the impact of possible releases to the environs of radionuclides from the operations of the Cooper Nuclear Station. This objective requires measurements of low levels of radioactivity equal to or lower than pre-determined limits of detection. In addition the source of the environmental radiation must be established. SQurces of environmental radiation include:

(1) Natural background radiation from cosmic rays (Beryllium-7).

(2) Terrestrial, primordial radionuclides from the environment (potassium-40, radium-226, thorium-228).

(3) Fallout from atmospheric nuclear tests such as the September 1977 detonation by the Peoples' Republic of China and the atmospheric weapons test of October 16, 1980 (fission products and fusion products).

(4) Releases from nuclear power plants such as CNS (fission products and neutron activation products).

(5) Fallout from the Chernobyl Nuclear Reactor Accident.

Radiation levels measured in the vicinity of an operating power station are compared with preoperational measurements at the same locations to distinguish power plant effects from other sources. Also, results of the monitoring program are related to events known to cause elevated levels of radiation in the environment, e.g., atmospheric nuclear detonations or abnormal plant releases.

9

SECTION II.

SUMMARY

10

H.

SUMMARY

Presented in this report are summaries and discussions of the data generated for the Radiological Environmental Monitoring Program (REMP) for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) for 2009.

The sampling and analyses program is described in Section III. It contains the sampling schedule and required analyses in Table 1 and the site map.

A discussion of each type of sample analyzed and its impact, if any, on the environment is presented in Section IV. Included are graphs of the radionuclides of interest for the past several years and the statistical results for each quarter of the year.

Section V presents the yearly conclusions of the program.

Section VI is the Radiological Environmental Monitoring Program Summary. It contains the yearly summary of the program with the total number of samples of each type analyzed. It lists the yearly average and range for the control locations versus the indicator locations and the number of detections per total number of samples. It identifies the station with the highest yearly average, the distance and location of that station and provides the range of detection.

Section VII contains the complete data tables for the period.

References are presented in Section VIII.

11

SECTION III. SAMPLING AND ANALYSES PROGRAM 12

HI. SAMPLING AND ANALYSES PROGRAM The 2009 sampling and analyses program is described in Table 1. Teledyne Brown Engineering - Environmental Services has a comprehensive quality assurance/quality control program designed to assure the reliability of data obtained. The results for the 2009 Interlaboratory Comparison Program conducted by the Analytics',

Inc., MAPEP and Environmental Resource Associates are contained in Appendix B.

Sampling locations are indicated in the map labeled Figure 1. The sample types collected at each location and the approximate distance and direction from the reactor elevated release point are specified.

The annual land use census for 2009 is described in Appendix A. There were no milk animals found within three miles of CNS in 2009 and no evidence of potable water use from the river. The nearest garden to CNS is in sector L, 1.3 miles from CNS.

Gardens were found in nine sectors during 2000, in eight sectors during 2001, in seven sectors during 2002, in eight sectors during 2003, in nine sectors during 2004, in five sectors during 2005, in nine sectors during 2006, in seven sectors during 2007, in six sectors during 2008 and in nine sectors during 2009. The nearest resident to CNS is in sector Q, 0.9 miles from CNS.

All of the required 2009 environmental monitoring, including sampling and analyses, was conducted as specified in Table D4.1-1 of the CNS Offsite Dose Assessment Manual (ODAM), except as noted in Appendix E, REMP Sampling and Analytical Exceptions table.

13

TABLE 1 NEBRASKA PUBLIC POWER DISTRICT COOPERNUCLEAR STATION EnvironmentalRadiation Surveillance Program Sampling Schedule and Analyses Sample Type Station Frequency Analyses Airborne/ 1-10 Once per 7 days Gross beta. Gamma Isotopic Particulate on quarterly composite of each station, and on each sample in which gross beta activity is >10 times the yearly mean of control samples Airborne/Iodine 1-10 Once per 7 days 1-131 Milk / Nearest Producer peak 99 Once per 15 days 1-131 (low level), Gamma Isotopic pasture only analysis of each sample River Water 28, 35 Once per 31 days Gamma Isotopic, each sample Tritium on quarterly composite Milk/ Nearest Producer 99 Once per 31 days 1-131 (low level), Gamma Isotopic analysis Non-peak pasture of each sample Food Products / Broadleaf 28, 35, 96, 101 Monthly when 1-131 (low level), Gamma Isotopic analysis Vegetation required of each sample Background Radiation 1-10, 20, 44, 56, 58, 59, Once per 92 days TLD Readout Thermoluminescent 66, 67, 71, 79-91, 94, (gamma dose)

Dosimeters Groundwater 11,47 Once per 92 days 1-131 (low level), Gamma Isotopic, Tritium Milk Other Producers 103 Once per 92 days 1-131 (low level), Gamma Isotopic Fish (Summer and Fall) 28, 35 Two times per year Gamma Isotopic on edible portions Shoreline Sediment 28, 35 Two times per year Gamma Isotopic 14

l.A N

r

  • ftftwdNo b I'_ I -~ win
  • IwweA Oft*y ft a" -ENE -- I . Lb" 00 bwb-md ISWSW Sk SAMKM L,,ATION KEY tSMTfl NmwVu (00) - (do") c .u..... T$(s) 1 01 o0 No APC, TL 2 0.15 210 a AP,C, TL 11 0.15 275 IND we 12 V.1 ,X5 CON WR a.g o0 315 w T.

1.1 234 140 TL 86 1 170 1N 11.

79 O08 24N TI.

so 07. 260 No TL.

81 OA 256 go TI.

82 $ 1w In 4 TL.

"0,- dm o Am*d

-0,~ nm '~

SECTION IV.

SUMMARY

AND DISCUSSION OF 2009 ANALYTICAL RESULTS 17

IV.

SUMMARY

AND DISCUSSION OF 2009 ANALYTICAL RESULTS Data from the radiological analyses of environmental media collected during 2009 are tabulated and discussed below. The procedures and specifications followed in the laboratory for these analyses are as required in the Teledyne Brown Engineering Quality Assurance manual and are explained in the Teledyne Brown Engineering Analytical Procedures. A synopsis of analytical procedures used for the environmental samples is provided in Appendix C. In addition to internal quality control measures performed by Teledyne Brown Engineering, the laboratory also participates in an Interlaboratory Comparison Program. Participation in this program ensures that independent checks on the precision and accuracy of the measurements of radioactive material in environmental samples are performed. The results of the Interlaboratory Comparison are provided in Appendix B.

Radiological analyses of environmental media characteristically approach and frequently fall below the detection limits of state-of-the-art measurement methods. The "less than" values in the data tables were calculated from each specific analysis and are dependent on sample size, detector efficiency, length of counting time, chemical yield (when appropriate) and the radioactive decay factor from time of counting to time of collection. Teledyne Brown Engineering's analytical methods meet or are below the Lower Limit of Detection (LLD) requirements given in Table 2 of the USNRC Branch Technical Position, Radiological Monitoring Acceptable Program (November 1979, Revision 1). Appendix C contains a discussion of the LLD formulas.

The following is a discussion and summary of the results of the environmental measurements taken during the 2009 reporting period (Graphs now only reflect the last ten years data):

18

A. Airborne Particulates Gross beta activity was observed in 515 of the 518 indicator samples collected during 2009. The average concentration was 0.022 pCi/m 3 with a range of 0.008 to 0.096 pCi/m 3. The results of the gross beta activities are presented in Section VII-1 and Trending Graph 1. The gross beta activities for 2009 were comparable to levels measured in the previous several years. Prior to that period the gross beta activities were higher due to atmospheric nuclear weapons testing performed in other countries. The preoperational period of 1971 through 1974 averaged 0.098 pCi/m 3 gross beta.

Air particulate filters were collected weekly and composited by locations on a quarterly basis. They were analyzed by gamma ray spectroscopy. The results are presented in Section VII-2. Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation, was measured in 29 of 40 composite3 samples. The indicator locations had an average concentration of 0.166 pCi/m with a range of 0.098 to 0.250 pCi/m 3. During the preoperational period, beryllium-7 was measured at comparable levels. Thorium-228 was measured in one sample at a concentration of 0.018 pCi/m 3 . All other gamma emitters were below the detection limits.

TRENDING GRAPH 1 GROSS BETA IN AIR PARTICULATES MONTHLY AVERAGE - ALL LOCATIONS 0.1 0.01 E

(3 a.

0.001 I NGrossBea 1 19

B. Airborne Iodine Charcoal cartridges used to collect airborne iodine were collected weekly and analyzed by gamma spectrometry for iodine-131. Stations 01 through 10 were monitored. The results are presented in Section VII-1 and Trending Graph 2. All results were below the required lower limit of detection.

TRENDING GRAPH 2 IODINE-131 IN CHARCOAL FILTERS MONTHLY AVERAGE - ALL LOCATIONS 1.00 0.10 8 0.01 WV0010,41 (3 0.0 0.00 oJ 5~

r -- 1--131 -u-ODAM LLDo Trending Graph 2 represents minimum detectable concentration (MDC) results. This graph has the ODAM LLD trend line, showing the MDC results as below the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

20

C. Fish Aquatic biota can be sensitive indicators of radionuclide accumulation in the environment because of their ability to concentrate certain chemical elements, which have radioisotopes. The results are presented in Table VII-3 and Trending Graph 3. Eight samples of fish were collected during the summer and fall of 2009. A middle-top feeding fish (carp) and a bottom feeding fish (catfish) were collected in July and September. These samples were analyzed by gamma ray spectroscopy. Naturally occurring potassium-40 was detected in all samples. The average concentration at the upstream control location was 3083 pCi/kg (wet weight) with a range of 2790 to 3550 pCi/kg (wet weight). The average concentration for the four indicator samples was 3210 pCi/kg (wet weight) with a range of 2890 to 3860 pCi/kg (wet weight). The preoperational period of 1971 through 1974 averaged 2400 pCi/kg potassium-40. All other gamma emitters were below their detection levels.

TRENDING GRAPH 3 CESIUM-137 IN FISH ALL LOCATIONS 1000 100

'IM*

-4 10

0. -o S--4.-Cs-137 -UCs-137ODAM LLD I Trending Graph 3 represents minimum detectable concentration (MDC) results. This graph has the ODAM LLD trend line, showing the MDC results as belo the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

21

D. Milk - NearestProducer Milk samples are collected once every 15 days in peak pasture season and once every 31 days the rest of the year from Station 99. The results are presented in Table VII-4 and Trending Graph 4. Sixteen samples were analyzed by gamma ray spectroscopy and for low-level iodine-131 by radiochemical separation.

Naturally occurring potassium-40 was measured in all samples with an average concentration of 1254 pCi/liter and a range of 1070 to 1480 pCi/liter.

Thorium-228 was measured in one sample at a concentration of 13.6 pCi/liter.

All other gamma emitters were below their detection levels.

TRENDING GRAPH 4 IODINE-131 AND CESIUM-137 IN MILK - NEAREST PRODUCER STATIONS 61 & 99 100.0 10.0 0.

1.0 0.1 1 I I I

-- Station 611-131 -U-Station 61 Cs-137

-- Station 991-131 --- Station 99 Cs-1 37

-A-1-131 ODAM LLD Cs-137 ODAM LLD Station 61 went out of business in May of 2003. Station 99 replaced station 61 in May of 2003.

Trending Graph 4 represents minimum detectable concentration (MDC) results. This graph has the ODAM LLD trend line, showing the MDC results as below the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

22

E. Milk - Other Producers Four milk samples were collected from one location of other producers during 2009 and results are presented in Table VII-5 and Trending Graph 5. Station 103 was sampled quarterly in 2009. Naturally occurring potassium-40 was detected in all four samples analyzed with an average concentration of 1268 pCi/liter and a range of 1170 to 1430 pCi/liter. All other gamma emitters were below their detection levels. The operation of the Cooper Nuclear Station has no discernable impact on milk samples.

TRENDING GRAPH 5 IODINE-131 AND CESIUM-137 IN MILK - OTHER PRODUCERS QUARTERLY AVERAGE - ALL LOCATIONS 100.0 10 10.0 0.1 "b L k I --.-I-1 31 -uCS-1 37 -h--131 ODAM LLD --E-Cs-1 37 ODAM LLD I Due to delay in analysis, sample results for 1-131 for the first quarter of 2001 were excluded and are not plotted.

Milk station 102 went out of business April 2006. Vegetation samples are taken in lieu of milk.

Trending Graph 5 represents minimum detectable concentration (MDC) results. This graph has the ODAM LLD trend line, showing the MDC results as belo the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

23

F. Ground Water Groundwater was collected from two stations quarterly and analyzed for tritium and for gamma emitting radionuclides. Station 11 is located 0.15 miles from the plant and station 47 is 25.8 miles from the plant. The results are presented in Table VII-6 and Trending Graph 6. All results were below the required lower limit of detection.

TRENDING GRAPH 6 TRITIUM IN GROUND WATER QUARTERLY AVERAGE - ALL LOCATIONS 10000 1000 54,

0. 100 10

-le 0 0 41 10 Ile )e' 0 0 Ile ýý 5ý1 ý' 0

)0111 ýý 0

"b* If, 0 0

-101, ýý 0 0 0 13011, -s-all --le 41111 I NuH-3 -*-H-3ODAM LLD I Trending Graph 6 represents minimum detectable concentration (MDC) results. This graph has the ODAM LLD trend line, showing the MDC results as below the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

24

G. River Water River water was collected monthly and monitored for gamma emitting radionuclides. A quarterly composite was measured for tritium. The results are presented in Table VII-7 and Trending Graph 7. All results were below the required lower limit of detection. Naturally occurring potassium-40 was detected in two of twenty-four samples analyzed with an average concentration of 147 pCi/liter and a range of 105 to 189 pCi/liter. Naturally occurring Th-228 was detected in one of twenty-four samples analyzed, with a concentration of 5.36 pCi/liter. All other gamma emitters were below their detection levels.

TRENDING GRAPH 7 TRITIUM IN RIVER WATER QUARTERLY AVERAGE - ALL LOCATIONS 10000 1000 100 06 10 .. . . . ........ ........

1

-.- K--3 -H-3 ODAM LLD Trending Graph 7 represents minimum detectable concentration (MDC) results. This graph has the ODAM LLD trend line, showing the MDC results as below the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

25

H. ThermoluminescentDosimeters Thermoluminescent dosimeters (TLDs) determine environmental radiation doses and the results are presented in Table VII-8 and Trending Graph 8. Ambient radiation was monitored at 32 locations within an 11 mile radius of the Cooper Nuclear Station and collected quarterly. The quarterly average for the indicator locations was 22.7 millirem/quarter and a range from 19.4 to 30.0 millirem/quarter. The control station 44, which is located 10.3 miles, 270 degrees, had an average of 24.2 millirem/quarter and a range from 22.8 to 25.5 millirem/quarter. The highest station was Station 86 with an average of 24.8 millirem/quarter and a range from 22.9 to 30.0 millirem/quarter. The preoperational period of 1971 through 1974 averaged 7.0 millirem/quarter. The data from year to year is in good agreement and indicates no adverse changes in radiation exposure to the population near the Cooper Nuclear Station.

TRENDING GRAPH 8 THERMOLUMINESCENT DOSIMETRY QUARTERLY AVERAGE - ALL LOCATIONS 1000 100 10 I

N40 14,p 0 o'T4p 'V e 4p IV 1P11 I --*-Exposure Pathway - Ambient Gamma Radiation -i First quarter 2001 TLD data low but still within acceptable limits due to possible dry conditions.

26

I. Food- BroadleafVegetation Eight broadleaf vegetation samples were collected in June, July and August from three locations during 2009, due to broadleaf vegetation samples being unavailable in May and September. The samples were analyzed by gamma ray spectroscopy and for low-level iodine-131 by radiochemical separation. The results are presented in Table VII-9 and Trending Graph 9. Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation was measured in all eight samples analyzed. The average concentration for the two indicator locations was 1426 pCi/kg wet and a range of 588 to 2730 pCi/kg wet.

The average concentration for the control location was 766 pCi/kg wet with a range of 624 to 1020 pCi/kg wet. Naturally occurring potassium-40 was measured in all eight samples analyzed. The average concentration for the two indicator locations was 5394 pCi/kg wet and a range of 2580 to 7090 pCi/kg. The average concentration for the control location was 5253 pCi/kg wet with a range of 4030 to 6740 pCi/kg wet. Naturally occurring thorium-228 was measured in four of eight samples. The average concentration for the two indicator locations was 61.2 pCi/kg wet and a range of 31.5 to 90.9 pCi/kg. The average concentration for the control location was 17.8 pCi/kg wet with a range of 12.2 to 23.3 pCi/kg wet. All other gamma emitters were below their detection levels.

The operation of the Cooper Nuclear Station has no discernable impact on broadleaf vegetation samples.

TRENDING GRAPH 9 IODINE-131 AND CESIUM-137 IN FOOD- BROADLEAF VEGETATION ALL LOCATIONS 1000

£1l 10 10

--- 1-131 -- *-1-131 ODAM LLD -Cs-137 -N-Cs-137ODAM LLD:]

The low Cs-137 value reported in July 2001 was due to the wrong aliquot being entered for the gamma analysis resulted in an invalid analysis and is not reported Due to delay in sample receipt, the 1-131 had decayed away, resulting in an invalid analysis for May 2002 and is not reported.

Milk samples were collected in lieu of broadleaf vegetation samples in 2004 and 2005.

Due to delay in counting sample, the 1-131 had decayed away, resulting in an invalid analysis for June 2006 and is not reported. The 1-131 by chemical separation met required 1-131 LLD.

Trending Graph 9 represents minimum detectable concentration (MDC) results. This graph has the ODAM 27

LLD trend line, showing the MDC results as below the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

28

J. Shoreline Sediment Sediment samples were collected during May and October from Stations 28 and 35 and were analyzed by gamma spectrometry. The results are presented in Table VII-10 and Trending Graph 10. A number of naturally occurring radionuclides were detected in these samples. Naturally occurring potassium-40 was observed in all four samples. The average concentration for the one supplemental station was 12650 pCi/kg (dry weight) and a range of 11400 to 13900 pCi/kg (dry weight). The average concentration for the one indicator station was 16950 pCi/kg (dry weight) and a range of 16700 to 17200 pCi/kg (dry weight).

Radium-226 was observed in one sample from the supplemental station and one sample from the indicator station. The concentration for the supplemental station was 1260 pCi/kg (dry weight). The concentration for the indicator station was 2080 pCi/kg (dry weight). Thorium-228 was observed in all samples. The concentration for the supplemental station was 869 pCi/kg (dry weight) a range of 807 to 930 pCi/kg (dry weight). The concentration for the indicator station was 1071 pCi/kg (dry weight) a range of 961 to 1180 pCi/kg (dry weight). All other gamma emitters were below their detection limits.

TRENDING GRAPH 10 CESIUM-134 AND CESIUM-137 IN SHORELINE SEDIMENT STATIONS 28 AND 35 1000 100

-' 101


Cs-i134 -*-Cs-137 --+-Cs-i34 ODAM LLD -Cs-137 ODAM LLD Trending Graph 10 represents minimum detectable concentration (MDC) results. Only was sample was collected in 2008. This graph has the ODAM LLD trend line, showing the MDC results as below the ODAM required LLDs. The upward trend indicates shortened detector count time in order to maximize the number of samples counted each day, and is not an indication that the trend will continue to increase above the LLD limit.

29

K. ErrataData There was no errata data for 2009.

30

SECTION V. CONCLUSIONS 31

V. CONCLUSIONS The results of the 2009 Radiological Environmental Monitoring Program (REMP) for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) have been presented. The report contains data tables, summaries, and discussions of the data and trending graphs.

Naturally occurring radioactivity and residual traces of fallout were observed in sample media in the expected ranges. They have been discussed individually in the text.

Observed radioactivity was at very low concentrations.

The results of the analyses have been presented. Based on the evidence of the Radiological Environmental Monitoring Program, the Nebraska Public Power District, Cooper Nuclear Station has had no discernable radiological impact on the environment and is operating within regulatory limits.

32

SECTION VI. RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

TABLE - 2009 33

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Cooper Nuclear Station Docket No. 50-298 Location of Facility Nemaha Nebraska Reporting Period January 1 2009 to December 31 2009 (County/State)

Type & Lower Limit All Indicator Control Medium of Pathway Total No. of Locations Location with Highest Annual Mean Location No. of Sampled of Analysis Detection(l) Mean(2) Name Meano(2) Meano(2) Reportable (Unit of Measurement) Performed (LLD) Range(2) Range(2) Range(2) Occurrences Air Iodine 1-131 518 0.07 ND(0/518) NA NA(0/0) NA(0/0) 0 (pCi/m 3) (ND-ND) (NA-NA) (NA-NA)

Air Particulate GR-B 518 NA 0.022(515/518) Sta. 01 0.025(52/55) NA(0/0) 0 (pCi/rn 3) (0.008/0.096) (0.01/0.096) (NA-NA)

BE-7 40 NA 0.166(29/40) Sta. 05 0.219(3/14) NA(0/0) 0 (0.098/0.250) (0.186/0.250) (NA-NA)

CO-60 40 NA ND(0/40) NA NA(0/0) NA(0/0) 0 (ND-ND) (NA-NA) (NA-NA)

TH-228 40 NA 0.018(1/40) Sta. 03 0.018(1/40) NA(0/0) 0 NA-NA NA-NA (NA-NA)

Fish K-40 8 NA 3210(4/4) Sta. 28 1.8 mi. 3210(4/4) 3083(4/4) 0 (pCi/kg Wet) (2890/3860) (2890/3860) (2790/3550)

CO-60 8 130 ND(0/4) NA NA(0/0) ND(0/4) 0 (ND-ND) (NA-NA) (ND-ND)

CS-137 8 150 ND(0/4) NA NA(0/0) ND(0/4) 0 (ND-ND) (NA-NA) (ND-ND)

(1) Nominal Lower Limit of Detection (LLD), as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketso.

(3) ND = Non Detectable.

(4) NA = Not Applicable.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Cooper Nuclear Station Docket No. 50-298 Location of Facility Nemaha Nebraska Reporting Period January 1 2009 to December 31 2009 (County/State)

Type & Lower Limit All Indicator Control Medium of Pathway Total No. of Locations Location with Highest Annual Mean Location No. of Sampled of Analysis Detection(l) Mean(2) Name Meano(2) Meano(2) Reportable (Unit of Measurement) Performed (LLD) Range(2) Range(2) Range(2) Occurrences Fish TH-228 8 NA ND(0/4) NA NA(0/0) ND(0/4) 0 (pCi/kg Wet) (ND-ND) (NA-NA) (ND-ND)

Milk Nearest 1-131 16 NA ND(0/16) NA NA(0/0) NA(0/0) 0 (pCi/L) (ND-ND) (NA-NA) (NA-NA)

K-40 16 NA 1254(16/16) Sta. 99 1254(16/16) NA(0/0) 0 (1070/1480) (1070/1480) (NA-NA)

RA-226 16 NA ND(0/16) NA NA(0/0) NA(0/0) 0 (ND-ND) (NA-NA) (NA-NA)

TH-228 16 NA 13.6(1/16) Sta. 99 13.6(1/16) NA(0/0) 0 NA-NA NA-NA (NA-NA)

Milk Others 1-131 4 1 ND(0/4) NA NA(0/0) NA(0/0) 0 (pCi/L) (ND-ND) (NA-NA) (NA-NA)

K-40 4 NA 1268(4/4) Sta. 103 13.5 mi. 1268(4/4) NA(0/0) 0 (1170/1430) (1170/1430) (NA-NA)

RA-226 4 NA ND(0/4) NA NA(0/0) NA(0/0) 0 (ND-ND) (NA-NA) (NA-NA)

(1) Nominal Lower Limit of Detection (LLD), as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketso.

(3) ND =Non Detectable.

(4) NA = Not Applicable,

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Cooper Nuclear Station Docket No. 50-298 Location of Facility Nemaha Nebraska Reporting Period January 1 2009 to December 31 2009 (County/State)

Type & Lower Limit All Indicator Control Medium of Pathway Total No. of Locations Location with Highest Annual Mean Location No. of Sampled of Analysis Detection(l) Mean(2) Name Meano(2) Meano(2) Reportable (Unit of Measurement) Performed (LLD) Range(2) Range(2) Range(2) Occurrences Milk Others TH-228 4 NA ND(0/4) NA NA(0/0) NA(0/0) 0 (pCi/L) (ND-ND) (NA-NA) (NA-NA)

Water - Ground 1-131 14 1 ND(0/14) NA NA(0/0) NA(0/0) 0 (pCi/L) (ND-ND) (NA-NA) (NA-NA)

H-3 14 2000 ND(0/14) NA NA(0/0) NA(0/0) 0 (ND-ND) (NA-NA) (NA-NA)

ON K-40 14 NA ND(0/14) NA NA(0/0) NA(0/0) 0 (ND-ND) (NA-NA) (NA-NA)

TH-228 14 NA ND(0/14) NA NA(0/0) NA(0/0) 0 (ND-ND) (NA-NA) (NA-NA)

River Water H-3 24 2000 ND(0/12) NA NA(0/0) ND(0/12) 0 (pCi/L) (ND-ND) (NA-NA) (ND-ND)

K-40 24 NA ND(0/12) Sta. 35 2.0 mi. 147(2/12) 147(2/12) 0 (ND-ND) (105/189) (105/189)

TH-228 24 NA ND(0/12) Sta. 35 2.0 mi. 5.36(1/12) 5.36(1/12) 0 (ND-ND) NA-NA NA-NA (1) Nominal Lower Limit of Detection (LLD), as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketso.

(3) ND =Non Detectable.

(4) NA = Not Applicable.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Cooper Nuclear Station Docket No. 50-298 Location of Facility Nemaha Nebraska Reporting Period January 1 2009 to December 31 2009 (County/State)

Type & Lower Limit All Indicator Control Medium of Pathway Total No. of Locations Location with Highest Annual Mean Location No. of Sampled of Analysis Detection(l) Mean(2) Name Meano(2) Meano(2) Reportable (Unit of Measurement) Performed (LLD) Range(2) Range(2) Range(2) Occurrences Thermoluminescence Gamma 127 NA 22.7(123/123) Sta. 86 4.6 mi. 24.8(4/4) 24.2(4/4) 0 Dosimeter Dose (19.4/30.0) (22.9/30.0) (22.8/25.5)

(mR/Standard Quarter) Quarterly Broadleaf Vegetation 1-131 8 60 ND(0/5) NA NA(0/0) ND(0/3) 0 (pCi/kg Wet) (ND-ND) (NA-NA) (ND-ND)

- BE-7 8 NA 1426(5/5) Sta. 101 1648(3/3) 766(3/3) 0 (588/2730) (684/2730) (624/1020)

K-40 8 NA 5394(5/5) Sta. 96 6650(2/2) 5253(3/3) 0 (2580/7090) (6210/7090) (4030/6740)

RA-226 8 NA ND(0/5) NA NA(0/0) ND(0/3) 0 (ND-ND) (NA-NA) (ND-ND)

TH-228 8 NA 61.2(2/5) Sta. 101 90.9(1/4) 17.8(2/3) 0 (31.5/90.9) NA-NA (12.2/23.3)

Shoreline Sediment BE-7 4 NA ND(0/2) NA NA(0/0) ND(0/2) 0 (pCi/kg Dry) (ND-ND) (NA-NA) (ND-ND)

(1) Nominal Lower Limit of Detection (LLD), as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketso.

(3) ND = Non Detectable.

(4) NA = Not Applicable.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Cooper Nuclear Station Docket No. 50-298 Location of Facility Nemaha Nebraska Reporting Period January 1 2009 to December 31_2009 (County/State)

Type & Lower Limit All Indicator Control Medium of Pathway Total No. of Locations Location with Highest Annual Mean Location No. of Sampled of Analysis Detection(l) Mean(2) Name Mean0(2) Meano(2) Reportable (Unit of Measurement) Performed (LLD) Range(2) Range(2) Range(2) Occurrences Shoreline Sediment K-40 4 NA 16950(2/2) Sta. 28 1.8mi. 16950(2/2) 12650(2/2) 0 (pCi/kg Dry) (16700/17200) (16700/.17200) (11400/13900)

CS-137 4 NA ND(0/2) NA NA(0/0) ND(0/2) 0 (ND-ND) (NA-NA) (ND-ND)

RA-226 4 NA 2080(1/2) Sta. 28 1.8 mi. 2080(1/2) 1260(1/2) 0 NA-NA NA-NA NA-NA 00 TH-228 4 NA 1071(2/2) Sta. 28 1.8 mi. 1071(2/2) 869(2/2) 0 (961/1180) (961/1180) (807/930)

(1) Nominal Lower Limit of Detection (LLD), as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in brackets).

(3) ND =Non Detectable.

(4) NA = Not Applicable.

SECTION VII. COMPLETE DATA TABLES 39

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 01 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCIICU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.41 E-02 +/- 4.36E-03 L.T. 7.E-02 01/06/09 01/13/09 1.OOE+04 CU.FT. 2.64E-02 +/- 4.48E-03 L.T. 5.E-02 01/13/09 01/20/09 1.OOE+04 CU.FT. 2.81 E-02 +/- 4.53E-03 L.T. 2.E-02 01/20/09 01/27/09 1.OOE+04 CU.FT. 3.21 E-02 +/- 4.91 E-03 L.T. 2.E-02 01/27/09 02/03/09 1.01 E+04 CU.FT. 1.49E-02 +/- 3.78E-03 L.T. 5.E-02 02/03/09 02/10/09 9.99E+03 CU.FT. 2.86E-02 +/- 4.87E-03 L.T. 1.E-02 02/10/09 02/17/09 1.01E+04 CU.FT. 2.46E-02 +/- 4.29E-03 L.T. 2.E-02 02/17/09 02/24/09 1.OOE+04 CU.FT. 3.29E-02 +/- 4.93E-03 L.T. 6.E-02 0

02/24/09 03/03/09 1.02E+04 CU.FT. 2.54E-02 +/- 4.47E-03 L.T. 2.E-02 03/03/09 03/10/09 9.90E+03 CU.FT. 1.77E-02 +/- 4.26E-03 L.T. 3.E-02 03/10/09 03/17/09 1.00E+04 CU.FT. 2.76E-02 +/- 4.69E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01 E+04 CU.FT. 1.83E-02 +/- 4.17E-03 L.T. 4.E-02 03/24/09 03/30/09 6.98E+03 CU.FT. 1.69E-02 +/- 4.82E-03 L.T. 6.E-02 03/30/09 04/07/09 8.29E+03 CU.FT. 1.75E-02 +/- 4.46E-03 L.T. 3.E-02 04/07/09 04/14/09 9.32E+03 CU.FT. 1.91 E-02 +/- 4.09E-03 L.T. 3.E-02 04/14/09 04/21/09 9.72E+03 CU.FT. 1.19E-02 +/- 3.52E-03 L.T. 2.E-02 04/21/09 04/28/09 8.24E+03 CU.FT. 1.43E-02 +/- 3.85E-03 L.T. 4.E-02 04/28/09 05/05/09 9.96E+03 CU.FT. 1.29E-02 +/- 3.75E-03 L.T. 2.E-02 05/05/09 05/12/09 9.98E+03 CU.FT. 1.39E-02 +/- 3.50E-03 L.T. 5.E-02 05/12/09 05/19/09 1.OOE+04 CU.FT. 1.01 E-02 +/- 2.96E-03 L.T. 4.E-02 05/19/09 05/26/09 1.01 E+04 CU.FT. 2.22E-02 +/- 4.22E-03 L.T. 6.E-02 05/26/09 06/02/09 1.01 E+04 CU.FT. 1.64E-02 +/- 3.82E-03 L.T. 4.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 1.16E-02 +/- 3.73E-03 L.T. 3.E-02 06/09/09 06/16/09 1.01E+04 CU.FT. 1.24E-02 +/- 3.52E-03 L.T. 4.E-02 06/16/09 06/23/09 9.92E+03 CU.FT. 1.26E-02 +/- 3.69E-03 L.T. 6.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 3.15E-02 +/- 6.48E-03 L.T. 7.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 01 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 1.70E-02 4.30E-03 L.T. 6.E-02 07/07/09 07/13/09 8.60E+03 CU.FT. 2.34E-02 4.79E-03 L.T. 7.E-02 07/13/09 07/21/09 1.16E+04 CU.FT. 1.78E-02 5.38E-03 L.T. 4.E-02 07/21/09 07/28/09 9.98E+03 CU.FT. 1.47E-02 5.97E-03 L.T. 5.E-02 07/28/09 08/03/09 8.70E+03 CU.FT. 1.68E-02 6.20E-03 L.T. 4.E-02 08/03/09 08/11/09 1.07E+04 CU.FT. 2.51 E-02 5.79E-03 L.T. 6.E-02 08/11/09 08/18/09 1.OOE+04 CU.FT. 2.15E-02 4.87E-03 L.T. 1.E-02 08/18/09 08/25/09 1.01 E+04 CU.FT. 1.85E-02 5.11E-03 L.T. 2.E-02 08/25/09 09/01/09 9.80E+03 CU.FT. 1.52E-02 5.24E-03 L.T. 3.E-02 09/01/09 09/08/09 1.OOE+04 CU.FT. 3.48E-02 6.41E-03 L.T. 7.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.75E-02 5.31E-03 L.T. 7.E-02 09/15/09 09/22/09 9.86E+03 CU.FT. 2.03E-02 6.28E-03 L.T. 1.E-02 09/22/09 09/29/09 9.97E+03 CU.FT. 1.47E-02 5.59E-03 L.T. 6.E-02 09/29/09 10/06/09 9.98E+03 CU .FT. 1.39E-02 3.61 E-03 L.T. 4.E-02 10/06/09 10/13/09 6.96E+03 CU.FT. 2.02E-02 7.43E-03 L.T. 7.E-02 10/13/09 10/20/09 7.39E+03 CU.FT. 2.26E-02 7.39E-03 L.T. 5.E-02 10/20/09 10/27/09 9.OOE+03 CU.FT. 1.68E-02 4.39E-03 L.T. 4.E-02 10/27/09 11/03/09 8.71 E+03 CU.FT. 2.35E-02 6.89E-03 L.T. 3.E-02 11/03/09 11/10/09 7.51 E+03 CU.FT. 3.84E-02 8.26E-03 L.T. 6.E-02 11/10/09 11/17/09 3.43E+03 CU.FT. 8.62E-02 1.70E-02 L.T. 1.E-01 11/17/09 11/24/09 3.67E+03 CU.FT. 9.60E-02 1.67E-02 L.T. 4.E-02 11/24/09 12/01/09 6.14E+03 CU.FT. 3.82E-02 9.37E-03 L.T. 4.E-02 12/01/09 12/08/09 9.85E+03 CU.FT. 1.86E-02 4.35E-03 L.T. 6.E-02 12/08/09 12/15/09 9.98E+03 CU .FT. 3.43E-02 6.50E-03 L.T. 6.E-02 12/15/09 12/22/09 1.01E+04 CU.FT. 4.84E-02 6.82E-03 L.T. 6.E-02 12/22/09 12/29/09 1.01 E+04 CU.FT. 2.72E-02 5.80E-03 L.T. 6.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 02 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.67E-02 +/- 4.53E-03 L.T. 7.E-02 01/06/09 01/13/09 1.00E+04 CU.FT. 2.84E-02 +/- 4.61E-03 L.T. 5.E-02 01/13/09 01/20/09 1.00E+04 CU.FT. 2.54E-02 +/- 4.35E-03 L.T. 2.E-02 01/20/09 01/27/09 1.OOE+04 CU.FT. 3.20E-02 +/- 4.90E-03 L.T. 2.E-02 01/27/09 02/03/09 1.01E+04 CU.FT. 1.32E-02 +/- 3.64E-03 L.T. 5.E-02 02/03/09 02/10/09 9.97E+03 CU.FT. 2.92E-02 +/- 4.91E-03 L.T. 2.E-02 02/10/09 02/17/09 1.01 E+04 CU.FT. 2.42E-02 +/- 4.26E-03 L.T. 2.E-02 02/17/09 02/24/09 9.98E+03 CU.FT. 3.16E-02 +/- 4.85E-03 L.T. 6.E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 3.12E-02 +/- 4.83E-03 L.T. 2.E-02 03/03/09 03/10/09 9.90E+03 CU.FT. 1.80E-02 +/- 4.28E-03 L.T. 3.E-02 03/10/09 03/17/09 1.OOE+04 CU.FT. 2.96E-02 +/- 4.82E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01 E+04 CU.FT. 1.73E-02 +/- 4.1OE-03 L.T. 7.E-02 03/24/09 03/30/09 8.61 E+03 CU.FT. 1.35E-02 +/- 3.89E-03 L.T. 5.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.31E-02 +/- 3.26E-03 L.T. 3.E-02 04/07/09 04/14/09 9.93E+03 CU.FT. 2.35E-02 +/- 4.26E-03 L.T. 2.E-02 04/14/09 04/21/09 1.02E+04 CU.FT. 1.23E-02 +/- 3.45E-03 L.T. 2.E-02 04/21/09 04/28/09 1.03E+04 CU.FT. 1.09E-02 +/- 3.03E-03 L.T. 3.E-02 04/28/09 05/05/09 9.68E+03 CU.FT. 1.02E-02 +/- 3.60E-03 L.T. 2.E-02 05/05/09 05/12/09 1.01 E+04 CU.FT. 1.27E-02 +/- 3.37E-03 L.T. 5.E-02 05/12/09 05/19/09 1.OOE+04 CU.FT. 1.14E-02 +/- 3.09E-03 L.T. 6.E-02 05/19/09 05/26/09 1.01E+04 CU.FT. 2.OOE-02 +/- 4.07E-03 L.T. 6.E-02 05/26/09 06/02/09 1.01 E+04 CU.FT. 1.63E-02 +/- 3.81 E-03 L.T. 4.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 1.37E-02 +/- 3.89E-03 L.T. 3.E-02 06/09/09 06/16/09 1.01E+04 CU.FT. 1.29E-02 +/- 3.56E-03 L.T. 4.E-02 06/16/09 06/23/09 9.93E+03 CU.FT. 1.25E-02 +/- 3.67E-03 L.T. 6.E-02 06/23/09 06/30/09 9.55E+03 CU.FT. 3.07E-02 +/- 6.84E-03 L.T. 4.E-02

VlI-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 02 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 4.81 E+03 CU.FT. 1.78E-02 + 7.59E-03 L.T. 7.E-02 07/07/09 07/13/09 8.30E+03 CU.FT. 2.60E-02 + 5.09E-03 L.T. 7.E-02 07/13/09 07/21/09 1.17E+04 CU.FT. 3.61E-02 +/- 6.15E-03 L.T. 4.E-02 07/21/09 07/28/09 9.97E+03 CU.FT. 1.26E-02 +/- 5.87E-03 L.T. 5.E-02 07/28/09 08/03/09 8.70E+03 CU.FT. 2.11E-02 +/- 6.43E-03 L.T. 4.E-02 08/03/09 08/11/09 1.15E+03 CU.FT. L.T. 7.E-02 L.T. 6.E-01 08/11/09 08/18/09 1.OOE+04 CU.FT. 2.04E-02 +/- 4.81 E-03 L.T. 3.E-02 08/18/09 08/25/09 1.01 E+04 CU.FT. 1.94E-02 +/- 5.17E-03 L.T. 5.E-02 08/25/09 09/01/09 1.OOE+04 CU.FT. 1.75E-02 +/- 5.29E-03 L.T. 5.E-02 09/01/09 09/08/09 1.01 E+04 CU.FT. 2.50E-02 +/- 5.89E-03 L.T. 6.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.53E-02 +/- 5.19E-03 L.T. 7.E-02 09/15/09 09/22/09 9.86E+03 CU.FT. 2.51E-02 +/- 6.51 E-03 L.T. 2.E-02 09/22/09 09/29/09 1.01 E+04 CU.FT. 1.20E-02 +/- 5.38E-03 L.T. 5.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.51E-02 +/- 3.70E-03 L.T. 7.E-02 10/06/09 10/13/09 1.OOE+04 CU.FT. 1.73E-02 +/- 5.36E-03 L.T. 4.E-02 10/13/09 10/20/09 1.OOE+04 CU.FT. 1.34E-02 +/- 5.28E-03 L.T. 6.E-02 10/20/09 10/27/09 1.OOE+04 CU.FT. 1.78E-02 +/- 4.14E-03 L.T. 7.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.54E-02 +/- 5.64E-03 L.T. 5.E-02 11/03/09 11/10/09 1.01 E+04 CU.FT. 2.56E-02 +/- 6.OOE-03 L.T. 7.E-02 11/10/09 11/17/09 9.97E+03 CU.FT. 3.69E-02 +/- 6.21 E-03 L.T. 6.E-02 11/17/09 11/24/09 1.03E+04 CU.FT. 3.71E-02 +/- 6.08E-03 L.T. 2.E-02 11/24/09 12/01/09 9.82E+03 CU.FT. 3.04E-02 +/- 6.19E-03 L.T. 6.E-02 12/01/09 12/08/09 1.02E+04 CU.FT. 2.18E-02 +/- 4.46E-03 L.T. 5.E-02 12/08/09 12/15/09 9.98E+03 CU.FT. 3.65E-02 +/- 6.60E-03 L.T. 6.E-02 12/15/09 12/22/09 1.01 E+04 CU.FT. 4.64E-02 +/- 6.73E-03 L.T. 6.E-02 12/22/09 12/29/09 1.01 E+04 CU.FT. 2.74E-02 +/- 5.80E-03 L.T. 6.E-02

VIl-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 03 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.36E-02 +/- 4.33E-03 L.T. 7.E-02 01/06/09 01/13/09 9.91 E+03 CU.FT. 2.35E-02 +/- 4.31E-03 L.T. 5.E-02 01/13/09 01/20/09 1.01 E+04 CU.FT. 2.22E-02 +/- 4.1OE-03 L.T. 2.E-02 01/20/09 01/27/09 1.01E+04 CU.FT. 3.09E-02 +/- 4.81E-03 L.T. 2.E-02 01/27/09 02/03/09 1.01E+04 CU.FT. 1.54E-02 +/- 3.81 E-03 L.T. 5.E-02 02/03/09 02/10/09 1.02E+04 CU.FT. 2.94E-02 +/- 4.86E-03 L.T. 2.E-02 02/10/09 02/17/09 1.01 E+04 CU.FT. 2.45E-02 +/- 4.28E-03 L.T. 2.E-02 02/17/09 02/24/09 9.91 E+03 CU.FT. 3.15E-02 +/- 4.87E-03 L.T. 6.E-02 02/24/09 03103/09 1.02E+04 CU.FT. 2.97E-02 +/- 4.74E-03 L.T. 2.E-02 03/03/09 03/10/Q9 1.OOE+04 CU.FT. 1.45E-02 +/- 4.OOE-03 L.T. 2.E-02 03/10/09 03/17/09 1.OOE+04 CU.FT. 2.20E-02 +/- 4.32E-03 L.T. 2.E-02 03/17/09 03/24/09 1.01 E+04 CU.FT. 1.13E-02 +/- 3.65E-03 L.T. 7.E-02 03/24/09 03/30/09 8.55E+03 CU.FT. 1.22E-02 +/- 3.80E-03 L.T. 5.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.27E-02 +/- 3.22E-03 L.T. 3.E-02 04107/09 04/14/09 1.01 E+04 CU.FT. 1.85E-02 +/- 3.84E-03 L.T. 2.E-02 04/14/09 04/22/09 1.15E+04 CU.FT. 1.43E-02 +/- 3.33E-03 L.T. 2.E-02 04/21/09 04/28/09 8.66E+03 CU.FT. 9.31 E-03 +/- 3.24E-03 L.T. 4.E-02 04/28/09 05/05/09 9.86E+03 CU.FT. 1.42E-02 +/- 3.88E-03 L.T. 2.E-02 05/05/09 05/12/09 1.01E+04 CU.FT. 1.20E-02 +/- 3.31E-03 L.T. 5.E-02 05/12/09 05/19/09 2.34E+03 CU.FT. L.T. 1.E-02 L.T. 3.E-01 05/19/09. 05/26/09 9.96E+03 CU.FT. 2.13E-02 +/- 4.20E-03 L.T. 6.E-02 05/26/09 06/02/09 1.02E+04 CU.FT. 1.58E-02 +/- 3.75E-03 L.T. 4.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 9.50E-03 +/- 3.56E-03 L.T. 3.E-02 06/09/09 06/16/09 1.01E+04 CU.FT. 1.48E-02 +/- 3.72E-03 L.T. 4.E-02 06/16/09 06/23/09 9.92E+03 CU.FT. 1.51E-02 +/- 3.88E-03 L.T. 6.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 2.26E-02 +/- 6.07E-03 L.T. 7.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 03 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 1.48E-02 +/- 4.14E-03 L.T. 6.E-02 07/07/09 07/13/09 8.49E+03 CU.FT. 1.95E-02 +/- 4.55E-03 L.T. 7.E-02 07/13/09 07/21/09 1.17E+04 CU.FT. 1.56E-02 +/- 5.23E-03 L.T. 4.E-02 07/21/09 07/28/09 1.OOE+04 CU.FT. 2.35E-02 +/- 6.39E-03 L.T. 5.E-02 07/28/09 08/03/09 8.66E+03 CU.FT. 2.02E-02 +/- 6.41 E-03 L.T. 4.E-02 08/03/09 08/11/09 1.12E+04 CU.FT. 2.25E-02 +/- 5.46E-03 L.T. 6.E-02 08/11/09 08/18/09 1.03E+04 CU.FT. 1.67E-02 +/- 4.47E-03 L.T. 2.E-02 08/18/09 08/25/09 9.96E+03 CU.FT. 2.37E-02 +/- 5.46E-03 L.T. 3.E-02 08/25/09 09/01/09 1.01 E+04 CU.FT. 1.70E-02 +/- 5.22E-03 L.T. 5.E-02 09/01/09 09/08/09 9.99E+03 CU.FT. 3.04E-02 +/- 6.21E-03 L.T. 6.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.26E-02 +/- 5.03E-03 L.T. 7.E-02 09/15/09 09/22/09 9.98E+03 CU.FT. 3.44E-02 +/- 6.87E-03 L.T. 2.E-02 09/22/09 09/29/09 1.01 E+04 CU.FT. 1.61 E-02 +/- 5.60E-03 L.T. 5.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.35E-02 +/- 3.56E-03 L.T. 7.E-02 10/06/09 10/13/09 1.01 E+04 CU.FT. 1.73E-02 +/- 5.32E-03 L.T. 7.E-02 10/13/09 10/20/09 1.01 E+04 CU.FT. 1.48E-02 +/- 5.31E-03 L.T. 6.E-02 10/20/09 10/27/09 9.96E+03 CU.FT. 1.46E-02 +/- 3.92E-03 L.T. 7.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.60E-02 +/- 5.67E-03 L.T. 5.E-02 11/03/09 11/10/09 9.98E+03 CU.FT. 2.63E-02 +/- 6.09E-03 L.T. 7.E-02 11/10/09 11/17/09 9.91 E+03 CU.FT. 2.80E-02 +/- 5.80E-03 L.T. 6.E-02 11/17/09 11/24/09 1.04E+04 CU.FT. 3.96E-02 +/- 6.16E-03 L.T. 2.E-02 11/24/09 12/01/09 9.74E+03 CU.FT. 3.45E-02 +/- 6.43E-03 L.T. 3.E-02 12/01/09 12/08/09 1.03E+04 CU.FT. 2.14E-02 +/- 4.40E-03 L.T. 5.E-02 12/08/09 12/15/09 1.01E+04 CU.FT. 3.42E-02 +/- 6.43E-03 L.T. 6.E-02 12/15/09 12/22/09 9.98E+03 CU.FT. 5.52E-02 +/- 7.17E-03 L.T. 3.E-02 12/22/09 12/29/09 1.01 E+04 CU.FT. 2.94E-02 +/- 5.91 E-03 L.T. 6.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 04 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.74E-02 +/- 4.58E-03 L.T. 7.E-02 01/06/09 01/13/09 9.86E+03 CU.FT. 2.50E-02 +/- 4.42E-03 L.T. 5.E-02 01/13/09 01/20/09 1.01 E+04 CU.FT. 2.16E-02 +/- 4.06E-03 L.T. 2.E-02 01/20/09 01/27/09 1.01 E+04 CU.FT. 2.68E-02 +/- 4.55E-03 L.T. 2.E-02 01/27/09 02/03/09 1.01 E+04 CU.FT. 2.05E-02 +/- 4.19E-03 L.T. 5.E-02 02/03/09 02/10/09 1.02E+04 CU.FT. 2.81 E-02 +/- 4.78E-03 L.T. 2.E-02 02/10/09 02/17/09 1.OOE+04 CU.FT. 2.13E-02 +/- 4.08E-03 L.T. 2.E-02 02/17/09 02/24/09 9.91 E+03 CU.FT. 2.83E-02 +/- 4.67E-03 L.T. 6.E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 3.08E-02 +/- 4.80E-03 L.T. 2.E-02 03/03/09 03/10/09 1.OOE+04 CU.FT. 1.66E-02 +/- 4.15E-03 L.T. 2.E-02 03/10/09 03/17/09 1.OOE+04 CU.FT. 2.35E-02 +/- 4.42E-03 L.T. 2.E-02 03/17/09 03/24/09 1.02E+04 CU.FT. 1.29E-02 +/- 3.75E-03 L.T. 6.E-02 03/24/09 03/30/09 8.49E+03 CU.FT. 1.62E-02 +/- 4.16E-03 L.T. 5.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.62E-02 +/- 3.49E-03 L.T. 3.E-02 04/07/09 04/14/09 1.02E+04 CU.FT. 2.19E-02 +/- 4.07E-03 L.T. 2.E-02 04/14/09 04/22/09 1.13E+04 CU.FT. 1.19E-02 +/- 3.18E-03 L.T. 2.E-02 04/21/09 04/28/09 8.72E+03 CU.FT. 1.22E-02 +/- 3.51E-03 L.T. 4.E-02 04/28/09 05/05/09 9.93E+03 CU.FT. 1.28E-02 +/- 3.75E-03 L.T. 2.E-02 05/05/09 05/12/09 1.03E+04 CU.FT. 1.71 E-02 +/- 3.69E-03 L.T. 5.E-02 05/12/09 05/19/09 1.01 E+04 CU.FT. 1.27E-02 +/- 3.20E-03 L.T. 6.E-02 05/19/09 05/26/09 9.93E+03 CU.FT. 2.14E-02 +/- 4.21 E-03 L.T. 6.E-02 05/26/09 06/02/09 1.02E+04 CU.FT. 1.52E-02 +/- 3.70E-03 L.T. 4.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 8.16E-03 +/- 3.45E-03 L.T. 3.E-02 06/09/09 06/16/09 1.01 E+04 CU.FT. 1.32E-02 +/- 3.59E-03 L.T. 3.E-02 06/16/09 06/23/09 9.92E+03 CU.FT. 1.39E-02 +/- 3.79E-03 L.T. 6.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 2.80E-02 +/- 6.32E-03 L.T. 7.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 04 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 2.OOE-02 4.50E-03 L.T. 6.E-02 07/07/09 07/13/09 8.49E+03 CU.FT. 1.88E-02 4.49E-03 L.T. 7.E-02 07/13/09 07/21/09 1.18E+04 CU.FT. 8.99E-03 4.86E-03 L.T. 4.E-02 07/21/09 07/28/09 1.OOE+04 CU.FT. 1.48E-02 5.97E-03 L.T. 5.E-02 07/28/09 08/03/09 8.66E+03 CU.FT. 1.24E-02 5.97E-03 L.T. 4.E-02 08/03/09 08/11/09 1.13E+04 CU.FT. 2.11 E-02 5.35E-03 L.T. 6.E-02 08/11/09 08/18/09 1.02E+04 CU.FT. 1.67E-02 4.50E-03 L.T. 2.E-02 08/18/09 08/25/09 9.97E+03 CU.FT. 1.74E-02 5.1 OE-03 L.T. 5.E-02 08/25/09 09/01/09 1.01 E+04 CU.FT. 1.75E-02 5.24E-03 L.T. 5.E-02 09/01/09 09/08/09 1.OOE+04 CU.FT. 2.67E-02 6.03E-03 L.T. 6.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.03E-02 4.90E-03 L.T. 7.E-02 09/15/09 09/22/09 9.92E+03 CU.FT. 2.30E-02 6.38E-03 L.T. 2.E-02 09/22/09 09/29/09 1.01 E+04 CU.FT. 8.13E-03 5.17E-03 L.T. 5.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.44E-02 3.64E-03 L.T. 7.E-02 10/06/09 10/13/09 1.01E+04 CU.FT. 1.55E-02 5.22E-03 L.T. 7.E-02 10/13/09 10/20/09 1.01 E+04 CU.FT. 1.91E-02 5.54E-03 L.T. 6.E-02 10120109 10/27/09 9.91 E+03 CU.FT. 1.96E-02 4.30E-03 L.T. 7.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.17E-02 5.45E-03 L.T. 5.E-02 11/03/09 11/10/09 9.99E+03 CU.FT. 2.71 E-02 6.12E-03 L.T. 7.E-02 11110/09 11/17/09 9.98E+03 CU.FT. 3.83E-02 6.28E-03 L.T. 6.E-02 11/17/09 11/24/09 1.03E+04 CU.FT. 4.06E-02 6.25E-03 L.T. 2.E-02 11/24/09 12/01/09 9.91 E+03 CU.FT. 2.64E-02 5.95E-03 L.T. 6.E-02 12/01/09 12/08/09 1.01 E+04 CU.FT. 2.55E-02 4.72E-03 L.T. 5.E-02 12/08/09 12/15/09 1.01 E+04 CU.FT. 4.79E-02 7.04E-03 L.T. 6.E-02 12/15/09 12/22/09 1.OOE+04 CU.FT. 5.05E-02 6.95E-03 L.T. 6.E-02 12/22/09 12/29/09 1.01 E+04 CU.FT. 2.54E-02 5.70E-03 L.T. 6.E-02

vII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 05 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.81 E-02 +/- 4.62E-03 L.T. 6.E-02 01/06/09 01/13/09 9.91 E+03 CU.FT. 2.55E-02 +/- 4.44E-03 L.T. 5.E-02 01/13/09 01/20/09 1.01 E+04 CU.FT. 2.40E-02 +/- 4.22E-03 L.T. 6.E-02 01/20/09 01/27/09 1.01E+04 CU.FT. 3.31 E-02 +/- 4.94E-03 L.T. 1.E-02 01/27109 02/03109 1.01E+04 CU.FT. 1.77E-02 +/- 3.99E-03 L.T. 6.E-02 02/03/09 02/10/09 1.01 E+04 CU.FT. 3.09E-02 +/- 4.98E-03 L.T. 2.E-02 02/10/09 02/17/09 1.01 E+04 CU.FT. 2.65E-02 +/- 4.41 E-03 L.T. 3.E-02 02/17/09 02/24/09 9.91 E+03 CU.FT. 2.95E-02 +/- 4.75E-03 L.T. 6.E-02 00 02/24/09 03/03/09 1.02E+04 CU.FT. 2.84E-02 +/- 4.66E-03 L.T. 2.E-02 03/03/09 03/10/09 1.OOE+04 CU.FT. 2.OOE-02 +/- 4.39E-03 L.T. 2.E-02 03/10/09 03/17/09 1.OOE+04 CU.FT. 2.23E-02 +/- 4.34E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01 E+04 CU.FT. 1.68E-02 +/- 4.07E-03 L.T. 7.E-02 03/24/09 03/30/09 8.53E+03 CU.FT. 1.35E-02 +/- 3.92E-03 L.T. 3.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.17E-02 +/- 3.14E-03 L.T. 3.E-02 04/07/09 04/14/09 1.01 E+04 CU.FT. 2.45E-02 +/- 4.28E-03 L.T. 6.E-02 04/14/09 04/22/09 1.14E+04 CU.FT. 1.64E-02 +/- 3.50E-03 L.T. 2.E-02 04/21/09 04/28/09 8.65E+03 CU.FT. 1.23E-02 +/- 3.54E-03 L.T. 4.E-02 04/28/09 05/05/09 9.97E+03 CU.FT. 1.53E-02 +/- 3.93E-03 L.T. 2.E-02 05/05/09 05/12/09 1.02E+04 CU.FT. 1.51 E-02 +/- 3.55E-03 L.T. 4.E-02 05/12/09 05/19/09 1.01 E+04 CU.FT. 1.20E-02 +/- 3.13E-03 L.T. 6.E-02 05/19/09 05/26/09 9.96E+03 CU.FT. 1.65E-02 +/- 3.84E-03 L.T. 5.E-02 05/26/09 06/02/09 1.02E+04 CU.FT. 2.15E-02 +/- 4.16E-03 L.T. 4.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 1.08E-02 +/- 3.67E-03 L.T. 2.E-02 06/09/09 06/16/09 9.1 8E+03 CU.FT. 9.93E-03 +/- 3.55E-03 L.T. 2.E-02 06/16/09 06/23/09 9.92E+03 CU.FT. 1.58E-02 +/- 3.94E-03 L.T. 5.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 2.29E-02 +/- 6.08E-03 L.T. 7.E-02 (I

vII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 05 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 1.46E-02 +/- 4.13E-03 L.T. 6.E-02 07107/09 07/13/09 8.49E+03 CU.FT. 2.27E-02 +/- 4.78E-03 L.T. 6.E-02 07/13/09 07/21/09 1.17E+04 CU.FT. 1.14E-02 +/- 5.02E-03 L.T. 4.E-02 07/21/09 07/28/09 1.OOE+04 CU.FT. 1.87E-02 +/- 6.16E-03 L.T. 6.E-02 07/28/09 08/03/09 8.66E+03 CU.FT. 1.33E-02 +/- 6.02E-03 L.T. 5.E-02 08/03/09 08/11/09 1.13E+04 CU.FT. 2.09E-02 +/- 5.34E-03 L.T. 6.E-02 08/11/09 08/18/09 1.03E+04 CU.FT. 2.08E-02 +/- 4.73E-03 L.T. 2.E-02 08/18/09 08/25/09 9.97E+03 CU.FT. 1.84E-02 +/- 5.16E-03 L.T. 5.E-02 08/25/09 09/01/09 1.01 E+04 CU.FT. 9.46E-03 +/- 4.77E-03 L.T. 5.E-02 09/01/09 09/08/09 1.OOE+04 CU.FT. 3.79E-02 +/- 6.56E-03 L.T. 7.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.46E-02 +/- 5.15E-03 L.T. 6.E-02 09/15/09 09/22/09 9.92E+03 CU.FT. 1.04E-02 +/- 5.75E-03 L.T. 2.E-02 09/22/09 09129/09 1.01 E+04 CU.FT. 1.11E-02 +/- 5.33E-03 L.T. 5.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.58E-02 +/- 3.76E-03 L.T. 7.E-02 10/06/09 10/13/09 1.01 E+04 CU.FT. 2.16E-02 +/- 5.55E-03 L.T. 7.E-02 10/13/09 10/20/09 1.01E+04 CU.FT. 1.18E-02 +/- 5.14E-03 L.T. 6.E-02 10/20/09 10/27/09 9.97E+03 CU.FT. 1.54E-02 +/- 3.98E-03 L.T. 7.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.63E-02 +/- 5.69E-03 L.T. 5.E-02 11/03/09 11/10/09 1.OOE+04 CU.FT. 2.99E-02 +/- 6.25E-03 L.T. 7.E-02 11/10/09 11/17/09 9.98E+03 CU.FT. 3.29E-02 +/- 6.02E-03 L.T. 6.E-02 11/17/09 11/24/09 1.03E+04 CU.FT. 3.93E-02 +/- 6.19E-03 L.T. 7.E-02 11/24/09 12/01/09 9.91 E+03 CU.FT. 2.70E-02 +/- 5.98E-03 L.T. 6.E-02 12/01/09 12/08/09 1.01E+04 CU.FT. 1.77E-02 +/- 4.22E-03 L.T. 5.E-02 12/08/09 12/15/09 1.01E+04 CU.FT. 3.56E-02 +/- 6.50E-03 L.T. 4.E-02 12/15/09 12/22/09 1.OOE+04 CU.FT. 5.38E-02 +/- 7.09E-03 L.T. 6.E-02 12122/09 12/29/09 1.00E+04 CU.FT. 3.15E-02 +/- 6.06E-03 L.T. 3.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 06 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.96E-02 4.71 E-03 L.T. 6.E-02 01/06/09 01/13/09 9.91 E+03 CU.FT. 2.80E-02 4.61 E-03 L.T. 5.E-02 01/13/09 01/20/09 1.01 E+04 CU.FT. 2.74E-02 4.46E-03 L.T. 6.E-02 01/20109 01/27/09 1.01 E+04 CU.FT. 2.93E-02 4.71 E-03 L.T. 1.E-02 01/27/09 02/03/09 1.01E+04 CU.FT. 1.48E-02 3.76E-03 L.T. 6.E-02 02/03/09 02/10/09 1.01 E+04 CU.FT. 2.47E-02 4.59E-03 L.T. 3.E-02 02/10/09 02/17/09 1.01 E+04 CU.FT. 2.45E-02 4.28E-03 L.T. 3.E-02 0,, 02/17/09 02/24/09 9.91 E+03 CU.FT. 2.80E-02 4.65E-03 L.T. 6.E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 2.74E-02 4.60E-03 L.T. 2.E-02 03/03/09 03/10/09 1.OOE+04 CU.FT. 1.63E-02 4.13E-03 L.T. 2.E-02 03/10/09 03/17/09 1.OOE+04 CU.FT. 2.64E-02 4.62E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01 E+04 CU.FT. 1.41 E-02 3.87E-03 L.T. 2.E-02 03/24/09 03/30/09 8.53E+03 CU.FT. 1.42E-02 3.98E-03 L.T. 3.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.24E-02 3.19E-03 L.T. 5.E-02 04/07/09 04/14/09 1.01 E+04 CU.FT. 1.99E-02 3.95E-03 L.T. 6.E-02 04/14/09 04/22/09 1.14E+04 CU.FT. 1.17E-02 3.14E-03 L.T. 2.E-02 04/21/09 04/28/09 8.60E+03 CU.FT. 1.41 E-02 3.73E-03 L.T. 4.E-02 04/28/09 05/05/09 9.92E+03 CU.FT. 1.45E-02 3.88E-03 L.T. 2.E-02 05/05/09 05/12/09 1.03E+04 CU.FT. 1.67E-02 3.66E-03 L.T. 4.E-02 05/12/09 05/19/09 1.01E+04 CU.FT. 1.16E-02 3.09E-03 L.T. 6.E-02 05/19/09 05/26/09 9.96E+03 CU.FT. 2.04E-02 4.13E-03 L.T. 5.E-02 05/26/09 06/02/09 1.02E+04 CU.FT. 1.71 E-02 3.85E-03 L.T. 4.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 1.01 E-02 3.61 E-03 L.T. 2.E-02 06/09/09 06/16/09 1.01 E+04 CU.FT. 1.14E-02 3.44E-03 L.T. 3.E-02 06/16/09 06/23/09 9.92E+03 CU.FT. 1.54E-02 3.90E-03 L.T. 5.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 3.07E-02 6.45E-03 L.T. 6.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 06 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 2.12E-02 4.58E-03 L.T. 6.E-02 07/07/09 07/13/09 8.49E+03 CU.FT. 2.13E-02 4.68E-03 L.T. 6.E-02 07/13/09 07/21/09 1.17E+04 CU.FT. 1.63E-02 5.27E-03 L.T. 4.E-02 07/21/09 07/28/09 1.00E+04 CU.FT. 2.55E-02 6.48E-03 L.T. 6.E-02 07/28/09 08/03/09 8.66E+03 CU.FT. 1.83E-02 6.30E-03 L.T. 4.E-02 08/03/09 08/11/09 1.13E+04 CU.FT. 1.04E-02 4.80E-03 L.T. 6.E-02 08/11/09 08/18/09 1.03E+04 CU.FT. 1.42E-02 4.31 E-03 L.T. 2.E-02 08/18/09 08/25/09 9.97E+03 CU.FT. 1.54E-02 4.99E-03 L.T. 5.E-02 08/25/09 09/01/09 1.01 E+04 CU.FT. 1.35E-02 5.01 E-03 L.T. 2.E-02 09/01/09 09/08/09 1.OOE+04 CU.FT. 2.81 E-02 6.09E-03 L.T. 7.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.52E-02 5.18E-03 L.T. 6.E-02 09/15109 09/22/09 9.92E+03 CU.FT. 2.39E-02 6.42E-03 L.T. 3.E-02 09/22/09 09/29/09 1.01 E+04 CU.FT. 1.77E-02 5.69E-03 L.T. 5.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.55E-02 3.73E-03 L.T. 6.E-02 10/06/09 10/13/09 1.01 E+04 CU.FT. 1.20E-02 5.01 E-03 L.T. 7.E-02 10/13/09 10/20/09 1.01 E+04 CU.FT. 1.21 E-02 5.16E-03 L.T. 3.E-02 10/20/09 10/27/09 9.97E+03 CU.FT. 1.26E-02 3.77E-03 L.T. 6.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.27E-02 5.50E-03 L.T. 3.E-02 11/03/09 11/10/09 9.99E+03 CU.FT. 3.15E-02 6.34E-03 L.T. 3.E-02 11/10/09 11/17/09 9.98E+03 CU.FT. 2.78E-02 5.76E-03 L.T. 5.E-02 11/17/09 11/24/09 1.03E+04 CU.FT. 3.73E-02 6.09E-03 L.T. 7.E-02 11/24/09 12/01/09 9.91 E+03 CU.FT. 2.83E-02 6.04E-03 L.T. 6.E-02 12/01/09 12/08/09 1.01 E+04 CU.FT. 2.02E-02 4.39E-03 L.T. 3.E-02 12/08/09 12/15/09 1.01 E+04 CU.FT. 4.07E-02 6.73E-03 L.T. 7.E-02 12/15/09 12/22/09 1.OOE+04 CU.FT. 5.38E-02 7.09E-03 L.T. 6.E-02 12/22/09 12/29/09 9.96E+03 CU.FT. 3.13E-02 6.07E-03 L.T. 5.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 07 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.61 E-02 +/- 4.49E-03 L.T. 6.E-02 01/06/09 01/13/09 1.OOE+04 CU.FT. 2.55E-02 +/- 4.42E-03 L.T. 5.E-02 01/13/09 01/20/09 1.OOE+04 CU.FT. 2.48E-02 +/- 4.31 E-03 L.T. 6.E-02 01/20/09 01/27/09 1.OOE+04 CU.FT. 3.09E-02 +/- 4.84E-03 L.T. 1.E-02 01/27/09 02/03/09 1.01 E+04 CU.FT. 1.42E-02 +/- 3.72E-03 L.T. 6.E-02 02/03/09 02/10/09 9.98E+03 CU.FT. 2.99E-02 +/- 4.95E-03 L.T. 3.E-02 02/10/09 02/17/09 1.01 E+04 CU.FT. 2.18E-02 +/- 4.09E-03 L.T. 3.E-02 k) 02/17/09 02/24/09 1.OOE+04 CU.FT. 3.08E-02 +/- 4.80E-03 L.T. 6.E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 2.64E-02 +/- 4.53E-03 L.T. 2.E-02 03/03/09 03/10/09 9.90E+03 CU.FT. 1.92E-02 +/- 4.36E-03 L.T. 2.E-02 03/10/09 03/17/09 1.OOE+04 CU.FT. 2.57E-02 +/- 4.57E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01 E+04 CU.FT. 1.66E-02 +/- 4.05E-03 L.T. 2.E-02 03/24/09 03/30/09 8.61 E+03 CU.FT. 1.63E-02 +/- 4.13E-03 L.T. 3.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.24E-02 +/- 3.19E-03 L.T. 5.E-02 04/07/09 04/14/09 9.93E+03 CU.FT. 2.OOE-02 +/- 4.OOE-03 L.T. 6.E-02 04/14/09 04/21/09 1.03E+04 CU.FT. 1.48E-02 +/- 3.62E-03 L.T. 3.E-02 04/21/09 04/28/09 1.01 E+04 CU.FT. 1.64E-02 +/- 3.56E-03 L.T. 4.E-02 04/28/09 05/05/09 9.90E+03 CU.FT. 1.40E-02 +/- 3.85E-03 L.T. 2.E-02 05/05/09 05/12/09 1.01 E+04 CU.FT. 1.55E-02 +/- 3.61 E-03 L.T. 4.E-02 05/12/09 05/19/09 1.OOE+04 CU.FT. 1.17E-02 +/- 3.12E-03 L.T. 7.E-02 05/19/09 05/26/09 1.01 E+04 CU.FT. 1.77E-02 +/- 3.90E-03 L.T. 5.E-02 05/26/09 06/02/09 1.01 E+04 CU.FT. 1.80E-02 +/- 3.94E-03 L.T. 4.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 1.57E-02 +/- 4.05E-03 L.T. 2.E-02 06/09/09 06/16/09 1.01 E+04 CU.FT. 1.05E-02 +/- 3.36E-03 L.T. 3.E-02 06/16/09 06/23/09 9.97E+03 CU.FT. 1.38E-02 +/- 3.77E-03 L.T. 5.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 2.57E-02 +/- 6.21 E-03 L.T. 6.E-&2

I VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 07 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 1.82E-02 +/- 4.38E-03 L.T. 6.E-02 07/07/09 07/13/09 8.59E+03 CU.FT. 2.05E-02 +/- 4.58E-03 L.T. 6.E-02 07113/09 07/21/09 1.17E+04 CU.FT. 1.43E-02 +/- 5.17E-03 L.T. 4.E-02 07/21/09 07/28/09 9.97E+03 CU.FT. 2.61 E-02 +/- 6.52E-03 L.T. 6.E-02 07/28/09 08/03/09 8.70E+03 CU.FT. 1.05E-02 +/- 5.84E-03 L.T. 5.E-02 08/03/09 08/11/09 1.12E+04 CU.FT. 2.65E-02 +/- 5.65E-03 L.T. 6.E-02 08/11/09 08/18/09 1.OOE+04 CU.FT. 2.07E-02 +/- 4.83E-03 L.T. 3.E-02

(-'I 08/18/09 08/25/09 1.01 E+04 CU.FT. 2.22E-02 +/- 5.32E-03 L.T. 5.E-02 08/25/09 09/01/09 1.01 E+04 CU.FT. 1.60E-02 +/- 5.16E-03 L.T. 4.E-02 09/01/09 09/08/09 1.OOE+04 CU.FT. 3.76E-02 +/- 6.54E-03 L.T. 7.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.22E-02 +/- 5.01 E-03 L.T. 6.E-02 09/15/09 09/22/09 9.86E+03 CU.FT. 2.61 E-02 +/- 6.55E-03 L.T. 3.E-02 09/22/09 09/29/09 1.01 E+04 CU.FT. 9.46E-03 +/- 5.24E-03 L.T. 5.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.18E-02 +/- 3.43E-03 L.T. 6.E-02 10/06/09 10/13/09 1.OOE+04 CU.FT. 1.43E-02 +/- 5.19E-03 L.T. 4.E-02 10/13/09 10/20/09 1.OOE+04 CU.FT. 2.23E-02 +/- 5.75E-03 L.T. 3.E-02 10/20/09 10/27/09 1.OOE+04 CU.FT. 1.54E-02 +/- 3.97E-03 L.T. 6.E-02 10127/09 11/03/09 1.02E+04 CU.FT. 1.85E-02 +/- 5.80E-03 L.T. 5.E-02 11/03/09 11/10/09 1.01E+04 CU.FT. 2.41 E-02 +/- 5.92E-03 L.T. 6.E-02 11/10/09 11/17/09 9.93E+03 CU.FT. 3.17E-02 +/- 5.98E-03 L.T. 5.E-02 11/17/09 11/24/09 1.03E+04 CU.FT. 4.16E-02 +/- 6.29E-03 L.T. 7.E-02 11/24/09 12/01/09 9.84E+03 CU.FT. 2.73E-02 +/- 6.03E-03 L.T. 5.E-02 12/01/09 12/08/09 1.02E+04 CU.FT. 2.28E-02 +/- 4.52E-03 L.T. 5.E-02 12/08/09 12/15/09 9.98E+03 CU.FT. 4.01 E-02 +/- 6.76E-03 L.T. 6.E-02 12/15/09 12/22/09 1.01 E+04 CU.FT. 5.80E-02 +/- 7.22E-03 L.T. 6.E-02 12/22/09 12/29/09 1.04E+04 CU.FT. 3.16E-02 +/- 5.89E-03 L.T. 6.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 08 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.01 E+04 CU.FT. 2.40E-02 +/- 4.39E-03 L.T. 6.E-02 01/06/09 01/13/09 9.99E+03 CU.FT. 2.81 E-02 +/- 4.59E-03 L.T. 5.E-02 01/13/09 01/20/09 9.97E+03 CU.FT. 2.23E-02 +/- 4.14E-03 L.T, 6.E-02 01/20/09 01/27/09 9.97E+03 CU.FT. 3.09E-02 +/- 4.84E-03 L.T. 1.E-02 01/27/09 02/03/09 1.01 E+04 CU.FT. 1.36E-02 +/- 3.67E-03 L.T. 6.E-02 02/03/09 02/10/09 9.92E+03 CU.FT. 3.25E-02 +/- 5.13E-03 L.T. 3.E-02 02/10/09 02/17/09 1.02E+04 CU.FT. 2.50E-02 +/- 4.28E-03 L.T. 3.E-02 02/17/09 02/24/09 9.98E+03 CU.FT. 3.08E-02 +/- 4.81E-03 L.T. 6.E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 3.05E-02 +/- 4.79E-03 L.T. 2.E-02 03/03/09 03/10/09 1.02E+04 CU.FT. 1.70E-02 +/- 4.12E-03 L.T. 2.E-02 03/10/09 03/17/09 9.86E+03 CU.FT. 2.45E-02 +/- 4.53E-03 L.T. 3.E-02 03/17/09 03/24/09 1.03E+04 CU.FT. 1.87E-02 +/- 4.14E-03 L.T. 2.E-02 03/24/09 03/30/09 8.47E+03 CU.FT. 1.64E-02 + 4.19E-03 L.T. 3.E-02 03/30109 04/07/09 1.14E+04 CU.FT. 1.47E-02 + 3.39E-03 L.T. 5.E-02 04/07/09 04/14/09 9.97E+03 CU.FT. 2.46E-02 + 4.32E-03 L.T. 6.E-02 04/14/09 04/21/09 1.03E+04 CU.FT. 1.51 E-02 + 3.65E-03 L.T. 3.E-02 04/21/09 04/28/09 1.01E+04 CU.FT. 1.36E-02 + 3.32E-03 L.T. 3.E-02 04/28/09 05/05/09 9.75E+03 CU.FT. 1.46E-02 + 3.94E-03 L.T. 2.E-02 05/05/09 05/12/09 1.01E+04 CU.FT. 1.40E-02 + 3.49E-03 L.T. 4.E-02 05/12/09 05/19/09 1.01 E+04 CU.FT. 8.20E-03 + 2.75E-03 L.T. 7.E-02 05/19/09 05/26/09 1.OOE+04 CU.FT. 2.27E-02 + 4.29E-03 L.T. 5.E-02 05/26/09 06/02/09 1.02E+04 CU.FT. 1.76E-02 +/- 3.88E-03 L.T. 4 .E-02 06/02/09 06/09/09 9.80E+03 CU.FT. 1.25E-02 + 3.86E-03 L.T. 2.E-02 06/09/09 06/16/09 1.04E+04 CU.FT. 9.19E-03 + 3.17E-03 L.T. 3.E-02 06/16/09 06/23/09 9.75E+03 CU.FT. 1.16E-02 + 3.65E-03 L.T. 5.E-02 06/23/09 06/30/09 1.02E+04 CU.FT. 2.72E-02 + 6.34E-03 L.T. 6.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 08 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.97E+03 CU.FT. 1.87E-02 4.40E-03 L.T. 6.E-02 07/07/09 07/13/09 8.53E+03 CU.FT. 1.82E-02 4.43E-03 L.T. 6.E-02 07/13/09 07/21/09 1.16E+04 CU.FT. 7.73E-03 4.87E-03 L.T. 4.E-02 07/21/09 07/28/09 1.01 E+04 CU.FT. 2.07E-02 6.20E-03 L.T. 6.E-02 07/28/09 08/03/09 8.59E+03 CU.FT. 1.98E-02 6.43E-03 L.T. 5.E-02 08/03/09 08/11/09 1.12E+04 CU.FT. 1.85E-02 5.26E-03 L.T. 6.E-02 08/11/09 08/18/09 1.02E+04 CU.FT. 1.70E-02 4.52E-03 L.T. 3.E-02 (J~ 08/18/09 08/25/09 1.OOE+04 CU.FT. 2.12E-02 5.31 E-03 L.T. 5.E-02 08/25/09 09/01/09 1.OOE+04 CU.FT. 1.42E-02 5.1 OE-03 L.T. 4.E-02 09/01/09 09/08/09 1.01E+04 CU.FT. 2.96E-02 6.12E-03 L.T. 7.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.39E-02 5.11 E-03 L.T. 6.E-02 09/15/09 09/22/09 9.86E+03 CU.FT. 1.97E-02 6.25E-03 L.T. 3.E-02 09/22/09 09/29/09 1.02E+04 CU.FT. 1.27E-02 5.38E-03 L.T. 5.E-02 09/29/09 10/06/09 9.98E+03 CU.FT. 1.20E-02 3.45E-03 L.T. 4.E-02 10/06/09 10/13/09 1.OOE+04 CU.FT. 1.19E-02 5.05E-03 L.T. 6.E-02 10/13/09 10/20/09 9.92E+03 CU.FT. 1.87E-02 5.60E-03 L.T. 3.E-02 10/20/09- 10/27/09 1.01 E+04 CU.FT. 1.49E-02 3.91 E-03 L.T. 6.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.22E-02 5.47E-03 L.T. 5.E-02 11/03/09 11/10/09 1.01 E+04 CU.FT. 3.02E-02 6.22E-03 L.T. 6.E-02 11/10/09 11/17/09 (a) 11/10/09 11/24/09 2.03E+04 CU.FT. 3.72E-02 3.87E-03 L.T. 5.E-02 11/24/09 12/01/09 9.79E+03 CU.FT. 2.82E-02 6.1 OE-03 L.T. 3.E-02 12/01/09 12/08/09 1.02E+04 CU.FT. 2.64E-02 4.75E-03 L.T. 5.E-02 12/08/09 12/15/09 1.OOE+04 CU.FT. 4.14E-02 6.81 E-03 L.T. 7.E-02 12/15/09 12/22/09 9.96E+03 CU.FT. 5.95E-02 7.35E-03 L.T. 5.E-02 12/22/09 12/29/09 (b)

(a) Sample unavailable due to the weather (b) Sample not taken

VIl-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 09 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.01 E+04 CU.FT. 2.27E-02 +/- 4.30E-03 L.T. 6,E-02 01/06/09 01/13/09 1.OOE+04 CU.FT. 2.67E-02 +/- 4.50E-03 L.T. 5.E-02 01/13/09 01/20/09 9.98E+03 CU.FT. 2.36E-02 +/- 4.23E-03 L.T. 6.E-02 01/20/09 01/27/09 9.98E+03 CU.FT. 3.25E-02 +/- 4.94E-03 L.T. 2.E-02 01/27/09 02/03/09 9.97E+03 CU.FT. 1.62E-02 +/- 3.90E-03 L.T. 7.E-02 02/03/09 02/10/09 1.OOE+04 CU.FT. 2.69E-02 +/- 4.76E-03 L.T. 2.E-02 02/10109 02/17/09 1.03E+04 CU.FT. 2.05E-02 +/- 3.95E-03 L.T. 2.E-02 02/17/09 02/24/09 9.92E+03 CU.FT. 2.82E-02 +/- 4.66E-03 L.T. 6,E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 2.61 E-02 +/- 4.51E-03 L.T. 2.E-02 03/03/09 03/10/09 9.87E+03 CU.FT. 1.83E-02 +/- 4.31E-03 L.T. 2.E-02 03/10/09 03/17/09 1.01E+04 CU.FT. 2.23E-02 +/- 4.32E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01E+04 CU.FT. 1.51 E-02 +/- 3.94E-03 L.T. 2.E-02 03/24/09 03/30/09 8.49E+03 CU.FT. 1.62E-02 +/- 4.16E-03 L.T. 4.E-02 03/30/09 04/07/09 1.07E+04 CU.FT. 1.31 E-02 +/- 3.42E-03 L.T. 5.E-02 04/07/09 04/14/09 9.79E+03 CU.FT. 2.30E-02 +/- 4.25E-03 L.T. 6.E-02 04/14/09 04/21/09 1.04E+04 CU.FT. 1.85E-02 +/- 3.88E-03 L.T. 4,E-02 04/21/09 04/28/09 9.97E+03 CU.FT. 1.38E-02 +/- 3.36E-03 L.T. 4.E-02 04/28109 05/05/09 9.84E+03 CU.FT. 1.35E-02 +/- 3.83E-03 L.T. 2,E-02 05/05/09 05/12/09 1.01E+04 CU.FT. 1.48E-02 +/- 3.55E-03 L.T. 5.E-02 05/12/09 05/19/09 1.01 E+04 CU.FT. 1.08E-02 +/- 3.02E-03 L.T. 3.E-02 05/19/09 05/26/09 1.01E+04 CU.FT. 1.97E-02 +/- 4.04E-03 L.T. 4.E-02 05/26/09 06/02/09 1.02E+04 CU.FT. 2.19E-02 +/- 4.19E-03 L.T. 5.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 1.23E-02 +/- 3.79E-03 L.T. 4.E-02 06/09/09 06/16/09 1.OOE+04 CU.FT. 1.06E-02 +/- 3.39E-03 L.T. 3.E-02 06/16/09 06/23/09 9.97E+03 CU.FT. 1.42E-02 +/- 3.80E-03 L.T. 6.E-02 06/23/09 06/30/09 1.02E+04 CU.FT. 2.81 E-02 +/- 6.38E-03 L.T. 6,E-02

V1t-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 09 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 1.58E-02 +/- 4.22E-03 L.T. 6.E-02 07/07/09 07/13/09 8.58E+03 CU.FT. 2.36E-02 +/- 4.82E-03 L.T. 7.E-02 07/13/09 07/21/09 1.16E+04 CU.FT. 1.58E-02 +/- 5.28E-03 L.T. 4.E-02 07/21109 07/28/09 1.01E+04 CU.FT. 1.76E-02 +/- 6.05E-03 L.T. 5.E-02 07/28/09 08/03/09 8.72E+03 CU.FT. L.T. 9.E-03 L.T. 3.E-02 08/03/09 08/11/09 1.10E+04 CU.FT. 2.61E-02 +/- 5.71E-03 L.T. 5.E-02 08/11/09 08/18/09 1.02E+04 CU.FT. 2.OOE-02 +/- 4.71E-03 L.T. 3.E-02 08/18/09 08/25/09 1.OOE+04 CU.FT. 2.27E-02 +/- 5.39E-03 L.T. 5.E-02 08/25/09 09/01/09 1.OOE+04 CU.FT. 1.42E-02 +/- 5.1OE-03 L.T. 4.E-02 09/01/09 09/08/09 1.01E+04 CU.FT. 3.OOE-02 +/- 6.14E-03 L.T. 6.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.05E-02 +/- 4.91E-03 L.T. 4.E-02 09/15/09 09/22/09 9.86E+03 CU.FT. 2.09E-02 +/- 6.31 E-03 L.T. 3.E-02 09/22/09 09/29/09 1.01E+04 CU.FT. 1.17E-02 +/- 5.36E-03 L.T. 7.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.15E-02 +/- 3.40E-03 L.T. 6.E-02 10/06/09 10/13/09 1.OOE+04 CU.FT. 1.28E-02 +/- 5.1OE-03 L.T. 6.E-02 10/13/09 10/20/09 9.91E+03 CU.FT. 1.34E-02 +/- 5.32E-03 L.T. 2.E-02 10/20/09 10/27/09 1.01E+04 CU.FT. 1.52E-02 +/- 3.93E-03 L.T. 6.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.68E-02 +/- 5.72E-03 L.T. 5.E-02 11/03/09 11/10/09 1.01 E+04 CU.FT. 2.78E-02 +/- 6.1OE-03 L.T. 6.E-02 11/10/09 11/17/09 9.87E+03 CU.FT. 3.25E-02 +/- 6.05E-03 L.T. 5.E-02 11/17/09 11/24/09 1.04E+04 CU.FT. 4.06E-02 +/- 6.21E-03 L.T. 5.E-02 11/24/09 12/01/09 9.81E+03 CU.FT. 2.56E-02 +/- 5.95E-03 L.T. 5.E-02 12/01/09 12/08/09 1.02E+04 CU.FT. 2.OOE-02 +/- 4.34E-03 L.T. 6.E-02 12/08/09 12/15/09 9.98E+03 CU.FT. 3.77E-02 +/- 6.65E-03 L.T. 6.E-02 12/15/09 12/22/09 1.02E+04 CU.FT. 5.61E-02 +/- 7.1OE-03 L.T. 6.E-02 12/22/09 12/29/09 1.01E+04 CU.FT. 3.05E-02 +/- 5.96E-03 L.T. 6.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 10 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.02E+04 CU.FT. 2.70E-02 +/- 4.55E-03 L.T. 6.E-02 01/06/09 01/13/09 1.OOE+04 CU.FT. 2.64E-02 +/- 4.48E-03 L.T. 5.E-02 01/13/09 01/20/09 1.01 E+04 CU.FT. 1.91 E-02 +/- 3.87E-03 L.T. 6.E-02 01/20/09 01/27/09 1.01 E+04 CU.FT. 2.94E-02 +/- 4.72E-03 L.T. 2.E-02 01/27/09 02/03/09 1.01 E+04 CU.FT. 1.44E-02 +/- 3.73E-03 L.T. 7.E-02 02/03/09 02/10/09 1.01 E+04 CU.FT. 2.56E-02 +/- 4.65E-03 L.T. 2.E-02 02/10/09 02/17/09 1.OOE+04 CU.FT. 2.25E-02 +/- 4.16E-03 L.T. 3.E-02 och 02/17/09 02/24/09 1.OOE+04 CU.FT. 3.30E-02 +/- 4.94E-03 L.T. 6.E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 2.99E-02 +/- 4.75E-03 L.T. 2.E-02 03/03/09 03/10/09 9.91 E+03 CU.FT. 2.06E-02 +/- 4.46E-03 L.T. 2.E-02 03/10/09 03/17/09 1.01 E+04 CU.FT. 2.81 E-02 +/- 4.70E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01 E+04 CU.FT. 2.27E-02 +/- 4.47E-03 L.T. 3.E-02 03/24/09 03/30/09 8.60E+03 CU.FT. 1.58E-02 +/- 4.1OE-03 L.T. 4.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.08E-02 +/- 3.07E-03 L.T. 4.E-02 04/07/09 04/14/09 9.97E+03 CU.FT. 2.17E-02 +/- 4.11E-03 L.T. 6.E-02 04/14/09 04/21/09 1.02E+04 CU.FT. 1.25E-02 +/- 3.46E-03 L.T. 4.E-02 04/21/09 04/28/09 1.OOE+04 CU.FT. 1.49E-02 +/- 3.46E-03 L.T. 4.E-02 04/28/09 05/05/09 9.93E+03 CU.FT. 1.20E-02 +/- 3.68E-03 L.T. 2.E-02 05/05/09 05/12/09 1.02E+04 CU.FT. 1.41 E-02 +/- 3.47E-03 L.T. 5.E-02 05/12/09 05/19/09 9.96E+03 CU.FT. 1.31 E-02 +/- 3.26E-03 L.T. 3.E-02 05/19/09 05/26/09 1.01 E+04 CU.FT. 2.13E-02 +/- 4.16E-03 L.T. 4.E-02 05/26/09 06/02/09 1.01 E+04 CU.FT. 1.86E-02 +/- 3.99E-03 L.T. 5.E-02 06/02/09 06/09/09 1.OOE+04 CU.FT. 1.30E-02 +/- 3.84E-03 L.T. 4.E-02 06/09/09 06/16/09 1.OOE+04 CU.FT. 1.46E-02 +/- 3.73E-03 L.T. 3.E-02 06/16/09 06/23/09 9.97E+03 CU.FT. 1.23E-02 +/- 3.65E-03 L.T. 6.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 2.28E-02 +/- 6.08E-03 L.T. 4.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 10 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.92E+03 CU.FT. 2.15E-02 +/- 4.60E-03 L.T. 6.E-02 07/07/09 07/13/09 8.59E+03 CU.FT. 2.39E-02 +/- 4.84E-03 L.T. 7.E-02 07/13/09 07/21/09 1.17E+04 CU.FT. 1.09E-02 +/- 5.OOE-03 L.T. 4.E-02 07/21/09 07/28/09 9.91 E+03 CU.FT. 1.99E-02 +/- 6.27E-03 L.T. 5.E-02 07/28/09 08/03/09 8.53E+03 CU.FT. 1.35E-02 +/- 6.12E-03 L.T. 4.E-02 08/03/09 08/11109 1.14E+04 CU.FT. 2.20E-02 +/- 5.36E-03 L.T. 5.E-02 08/11/09 08/18/09 1.OOE+04 CU.FT. 1.88E-02 +/- 4.71 E-03 L.T. 3.E-02 08/18/09 08/25/09 1.01E+04 CU.FT. 1.75E-02 +/- 5.05E-03 L.T. 5.E-02 08/25/09 09/01/09 1.01 E+04 CU.FT. 1.91E-02 +/- 5.33E-03 L.T. 4.E-02 09/01/09 09/08/09 1.OOE+04 CU.FT. 3.23E-02 +/- 6.29E-03 L.T. 6.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.56E-02 +/- 5.20E-03 L.T. 4.E-02 09/15/09 09/22/09 9.86E+03 CU.FT. 2.05E-02 +/- 6.29E-03 L.T. 2.E-02 09/22/09 09/29/09 1.01 E+04 CU.FT. 1.18E-02 +/- 5.37E-03 L.T. 7.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.46E-02 +/- 3.66E-03 L.T. 6.E-02 10/06/09 10/13/09 1.OOE+04 CU.FT. 1 1.97E-02 +/- 5.49E-03 L.T. 6.E-02 10/13/09 10/20/09 1.01 E+04 CU.FT. 1.77E-02 +/- 5.47E-03 L.T. 3.E-02 10/20/09 10/27/09 9.92E+03 CU.FT. 1.36E-02 +/- 3.86E-03 L.T. 5.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.48E-02 +/- 5.61 E-03 L.T. 5.E-02 11/03/09 11/10/09 1.02E+04 CU.FT. 3.06E-02 +/- 6.19E-03 L.T. 6.E-02 11/10/09 11/17/09 8.64E+03 CU.FT. 3.11E-02 +/- 6.60E-03 L.T. 6.E-02 11/17/09 11/24/09 9.51 E+03 CU.FT. 4.22E-02 +/- 6.69E-03 L.T. 6.E-02 11/24/09 12/01/09 9.85E+03 CU.FT. 2.65E-02 +/- 5.98E-03 L.T. 5.E-02 12/01/09 12/08/09 1.02E+04 CU.FT. 2.68E-02 +/- 4.78E-03 L.T. 5.E-02 12/08/09 12/15/09 9.98E+03 CU.FT. 3.53E-02 +/- 6.54E-03 L.T. 4.E-02 12/15/09 12/22/09 1.01 E+04 CU.FT. 4.73E-02 +/- 6.77E-03 L.T. 6.E-02 12/22/09 12/29/09 1.01 E+04 CU.FT. 3.34E-02 +/- 6.1OE-03 L.T. 6.E-02

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 01 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.59E-01 +/- 6.09E-02 L.T. 2.E-01 1.63E-01 +/- 9.29E-02 L.T. 2.E-01 K-40 L.T. 5.E-02 L.T. 5.E-02 L.T. 3.E-02 LT. 1.E-01 MN-54 L.T. 4.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 5.E-03 CO-58 L.T. 8.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. 8.E-03 FE-59 L.T. 2.E-02 L.T. 6.E-02 L.T. 4.E-02 L.T. 3.E-02 CO-60 L.T. 4.E-03 L.T. 3.E-03 L.T. 4.E-03 LT. 7.E-03 ZN-65 L.T. 1.E-02 L.T. 1.E-02 L.T. 9.E-03 L.T. 1.E-02 ZR-95 L.T. I.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-103 L.T. 1.E-02 L.T. 7.E-02 L.T. 2.E-02 L.T. 2.E-02 RU-1 06 L.T. 3.E-02 L.T. 3.E-02 L.T. 3.E-02 L.T. 5.E-02 1-131 L.T. 8.E+00 L.T. 1.E+04 L.T. 2.E+02 L.T. 3.E+00 CS-1 34 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 7.E-03 CS-1 37 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 5.E-03 BA-140 L.T. I.E+00 L.T. 1.E+02 L.T. 1.E+01 LT. 1.E+00 CE-141 L.T. 2.E-02 L.T. 1.E-01 L.T. 4.E-02 L.T. 4.E-02 CE-144 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 4.E-02 RA-226 L.T. 5.E-02 L.T. 5.E-02 L.T. 4.E-02 L.T. 1.E-01 TH-228 L.T. 5.E-03 L.T. 5.E-03 L.T. 5.E-03 L.T. 9.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 02 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.80E-01 +/- 6.17E-02 L.T. 3.E-01 1.57E-01 +/- 7.39E-02 1.36E-01 +/- 5.68E-02 K-40 L.T. 4.E-02 L.T. 4.E-02 L.T. 5.E-02 L.T. 7.E-02 MN-54 L.T. 3.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 5.E-03 CO-58 L.T. 5.E-03 L.T. 2.E-02 L.T. 8.E-03 L.T. 7.E-03 FE-59 L.T. 2.E-02 L.T. 1.E-01 L.T. 3.E-02 L.T. 3.E-02 CO-60 L.T. 3.E-03 L.T. 4.E-03 L.T. 2.E-03 L.T. 5.E-03 ZN-65 L.T. 1.E-02 L.T. 2.E-02 L.T. 8.E-03 L.T. 9.E-03 ZR-95 L.T. 1.E-02 L.T. 4.E-02 L.T. 2.E-02 L.T. 2.E-02 RU-103 L.T. 1.E-02 L.T. 7.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-1 06 L.T. 3.E-02 L.T. 5.E-02 L.T. 3.E-02 L.T. 4.E-02 1-131 L.T. 6.E+00 L.T. 1.E+04 L.T. 2.E+02 L.T. 2.E+00 CS-134 L.T. 3.E-03 L.T. 6.E-03 L.T. 4.E-03 L.T. 6.E-03 CS-137 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 5.E-03 BA-140 L.T. 1.E+00 L.T. 2.E+02 L.T. 9.E+00 L.T. 8.E-01 CE-141 L.T. 2.E-02 L.T. 1 .E-01 L.T. 5.E-02 L.T. 2.E-02 CE-144 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 RA-226 L.T. 5.E-02 L.T. 6.E-02 L.T. 5.E-02 L.T. 8.E-02 TH-228 L.T. 4.E-03 L.T. 6.E-03 L.T. 5.E-03 L.T. 6.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 03 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.35E-01 +/- 4.58E-02 L.T. 3.E-01 L.T. 2.E-01 1.21E-01 +/- 5.06E-02 K-40 L.T. 3.E-02 L.T. 5.E-02 2.21E-61 +/- 5.79E-02 L.T. 8.E-02 MN-54 L.T. 3.E-03 L.T. 4.E-03 L.T. 5.E-03 L.T. 4.E-03 CO-58 L.T. 6.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. 7.E-03 FE-59 L.T. 2.E-02 L.T. 1.E-01 L.T. 7.E-02 L.T. 2.E-02 CO-60 L.T. 3.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 4.E-03 ZN-65 L.T. 4.E-03 L.T. 1.E-02 L.T. 2.E-02 L.T. 1.E-02 ZR-95 L.T. 1.E-02 L.T. 4.E-02 L.T. 3.E-02 L.T. 1.E-02 RU-1 03 L.T. 9.E-03 L.T. 7.E-02 L.T. 3.E-02 L.T. 1.E-02 RU-1 06 L.T. 2.E-02 L.T. 4.E-02 L.T. 4.E-02 L.T. 4.E-02 1-131 L.T. 4.E+00 L.T. i.E+04 L.T. 2.E+02 L.T. 2.E+00 CS-134 L.T. 2.E-03 L.T. 5.E-03 L.T. 7.E-03 L.T. 4.E-03 CS-1 37 L.T. 2.E-03 L.T. 3.E-03 L.T. 5.E-03 L.T. 4.E-03 BA-140 L.T. I.E+00 L.T. 2.E+02 L.T. i.E+01 L.T. 8.E-01 CE-141 L.T. 1.E-02 L.T. 1.E-01 L.T. 7.E-02 L.T. 2.E-02 CE-144 L.T. 1.E-02 L.T. 2.E-02 L.T. 3.E-02 L.T. 2.E-02 RA-226 L.T. 4.E-02 L.T. 6.E-02 L.T. 6.E-02 L.T. 7.E-02 TH-228 L.T. 3.E-03 L.T. 5.E-03 1.83E-02 +/- 3.98E-03 L.T. 6.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 04 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06130/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.50E-01 + 4.93E-02 1.98E-01 +/- 1.26E-01 1.66E-01 +/- 5.91E-02 9.75E-02 +/- 4.76E-02 K-40 L.T. 4.E-02 L.T. 2.E-02 L.T. 4.E-02 L.T. 5.E-02 MN-54 L.T. 4.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 5.E-03 CO-58 L.T. 8.E-03 L.T. 1.E-02 L.T. 6.E-03 L.T. 8.E-03 FE-59 L.T. 3.E-02 L.T. 8.E-02 L.T. 3.E-02 L.T. 2.E-02 CO-60 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 ZN-65 L.T. 1.E-02 L.T. 1.E-02 L.T. 7.E-03 L.T. 8.E-03 ZR-95 L.T. 1.E-02 L.T. 3.E-02 L.T. 1.E-02 L.T. 1.E-02 RU-103 L.T. 1.E-02 L.T. 4.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-1 06 L.T. 4.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 4.E-02 1-131 L.T. 7.E+00 L.T. 1.E+04 L.T. 1.E+02 L.T. 2.E+00 CS-134 L.T. 4.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 4.E-03 CS-1337 L.T. 3.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 4.E-03 BA-140 L.T. I.E+00 - L.T. 1 .E+02 L.T. 6.E+00 L.T. 8.E-01 CE-141 L.T. 2.E-02 L.T. 1.E-01 L.T. 4.E-02 L.T. 2.E-02 CE-144 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 RA-226 L.T. 5.E-02 L.T. 4.E-02 L.T. 5.E-02 L.T. 7.E-02 TH-228 L.T. 5.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 6.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 05 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.86E-01 +/- 5.44E-02 2.50E-01 +/- 1.47E-01 2.22E-01 +/- 8.07E-02 L.T. 1.E-01 K-40 L.T. 4.E-02 L.T. 5.E-02 L.T. 4.E-02 L.T. 8.E-02 MN-54 L.T. 3.E-03 L.T. 3.E-03 L.T. 5.E-03 L.T. 5.E-03 CO-58 L.T. 6.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. 6.E-03 FE-59 L.T. 2.E-02 L.T. 9.E-02 L.T. 4.E-02 L.T. 2.E-02 CO-60 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 4.E-03 ZN-65 L.T. 9.E-03 L.T. 2.E-02 L.T. 9.E-03 L.T. 1.E-02 ZR-95 L.T. 9.E-03 L.T. 4.E-02 L.T. 2.E-02 L.T. 9.E-03 RU-1 03 L.T. 1.E-02 L.T. 7.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-106 L.T. 2.E-02 L.T. 3.E-02 L.T. 4.E-02 L.T. 4.E-02 1-131 L.T. 5.E+00 L.T. 1.E+04 L.T. 1.E+02 L.T. 2.E+00 CS-1 34 L.T. 3.E-03 L.T. 6.E-03 L.T. 3.E-03 L.T. 5.E-03 CS-137 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 5.E-03 BA-140 L.T. 1.E+00 L.T. 2.E+02 L.T. 1.E+01 L.T. 8.E-01 CE-141 L.T. 2.E-02 L.T. 2.E-01 L.T. 4.E-02 L.T. 2.E-02 CE-144 L.T. 1.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 RA-226 L.T. 4.E-02 L.T. 6.E-02 L.T. 5.E-02 L.T. 8.E-02 TH-228 L.T. 4.E-03 L.T. 6.E-03 L.T. 5.E-03 L.T. 7.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 06 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.59E-01 +/- 5.37E-02 L.T. 3.E-01 1.84E-01 +/- 7.62E-02 1.10E-01 +/- 4.40E-02 K-40 L.T. 5.E-02 L.T. 5.E-02 L.T. 3.E-02 L.T. 7.E-02 MN-54 L.T. 3.E-03 L.T. 5.E-03 L.T. 3.E-03 L.T. 5.E-03 CO-58 L.T. 5.E-03 L.T. 2.E-02 L.T. 8.E-03 L.T. 9.E-03 FE-59 L.T. 3.E-02 L.T. 8.E-02 L.T. 4.E-02 L.T. 2.E-02 CO-60 L.T. 3.E-03 L.T. 5.E-03 L.T. 2.E-03 L.T. 4.E-03 ZN-65 L.T. 7.E-03 L.T. 2.E-02 L.T. 9.E-03 L.T. 1.E-02 ZR-95 L.T. 1.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-1 03 L.T. 9.E-03 L.T. 7.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-1 06 L.T. 2.E-02 L.T. 4.E-02 L.T. 3.E-02 L.T. 4.E-02 1-131 L.T. 6.E+00 L.T. 1.E+04 L.T. 1.E+02 L.T. 2.E+00 CS-134 L.T. 3.E-03 L.T. 5.E-03 L.T. 3.E-03 L.T. 5.E-03 CS-137 L.T. 2.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 5.E-03 BA-140 L.T. i.E+00 L.T. 2.E+02 L.T. 7.E+00 L.T. 8.E-01 CE-141 L.T. 2.E-02 L.T. 1.E-01 L.T. 4.E-02 L.T. 2.E-02 CE-144 L.T. 1.E-02 LT. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 RA-226 L.T. 4.E-02 L.T. 6.E-02 L.T. 5.E-02 L.T. 8.E-02 TH-228 L.T. 4.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 7.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 07 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06130 - 09129/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.44E-01 +/- 7.39E-02 L.T. 2.E-01 1.69E-01 +/- 6.95E-02 LT. 1.E-01 K-40 L.T. 3.E-02 L.T. 2.E-02 L.T. 5.E-02 L.T. 6.E-02 MN-54 L.T. 3.E-03 L.T. 5.E-03 L.T. 5.E-03 L.T. 5.E-03 CO-58 L.T. 8.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. 7.E-03 ONý FE-59 L.T. 3.E-02 L.T. 1.E-01 L.T. 4.E-02 L.T. 3.E-02 ON CO-60 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 4.E-03 ZN-65 L.T. 1.E-02 L.T. 1.E-02 L.T. 9.E-03 L.T. 9.E-03 ZR-95 L.T. 1.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-103 L.T. 1.E-02 L.T. 6.E-02 L.T. 3.E-02 L.T. 2.E-02 RU-106 L.T. 3.E-02 L.T. 4.E-02 L.T. 4.E-02 L.T. 4.E-02 1-131 L.T. 7.E+00 L.T. 1.E+04 L.T. 1.E+02 L.T. 2.E+00 CS-134 L.T. 4.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 5.E-03 CS-137 L.T. 3.E-03 LT. 3.E-03 L.T. 3.E-03 L.T. 4.E-03 BA-140 L.T. 1.E+00 L.T. 1.E+02 L.T. 1.E+01 L.T. 8.E-01 CE-141 L.T. 2.E-02 L.T. 1.E-01 L.T. 5.E-02 L.T. 2.E-02 CE-144 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 RA-226 L.T. 5.E-02 L.T. 5.E-02 L.T. 5.E-02 L.T. 8.E-02 TH-228 L.T. 5.E-03 L.T. 5.E-03 L.T. 5.E-03 L.T. 7.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 08 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.86E-01 +/- 6.03E-02 L.T. 2.E-01 1.92E-01 +/- 7.06E-02 1.75E-01 +/- 6.79E-02 K-40 L.T. 5.E-02 L.T. 5.E-02 L.T. 5.E-02 L.T. 3.E-02 MN-54 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 6.E-03 CO-58 L.T. 5.E-03 L.T. 1.E-02 L.T. 6.E-03 L.T. I.E-02 FE-59 L.T. 2.E-02 L.T. 8.E-02 L.T. 3.E-02 L.T. 3.E-02 CO-60 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 ZN-65 L.T. 8.E-03 L.T. 1.E-02 L.T. 7.E-03 L.T. 1.E-02 ZR-95 L.T. 1.E-02 L.T. 3.E-02 L.T. 1.E-02 L.T. 1.E-02 RU-1 03 L.T. 1.E-02 L.T. 4.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-1 06 L.T. 3.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 4.E-02 1-131 L.T. 6.E+00 L.T. 9.E+03 L.T. 1.E+02 L.T. 3.E+00 CS-134 L.T. 3.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 5.E-03 CS-1 37 L.T. 3.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 5.E-03 BA-140 L.T. 1.E+00 L.T. 1.E+02 L.T. 7.E+00 L.T. 9.E-01 CE-141 L.T. 2.E-02 L.T. 1.E-01 L.T. 4.E-02 L.T. 2.E-02 CE-144 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 3.E-02 RA-226 L.T. 5.E-02 L.T. 4.E-02 L.T. 4.E-02 L.T. 8.E-02 TH-228 L.T. 4.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 7.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 09 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.48E-01 +/- 4.76E-02 2.42E-01 +/- 1.31E-01 L.T. 1.E-01 1.33E-01 +/- 4.99E-02 K-40 L.T. 4.E-02 L.T. 5.E-02 L.T. 3.E-02 L.T. 6.E-02 MN-54 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 1.E-03 CO-58 L.T. 5.E-03 L.T. 2.E-02 L.T. 9.E-03 L.T. 4.E-03 0O FE-59 L.T. 2.E-02 L.T. 6.E-02 L.T. 5.E-02 L.T. 2.E-02 CO-60 L.T. 3.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 2.E-03 ZN-65 L.T. 6.E-03 L.T. 2.E-02 L.T. 8.E-03 L.T. 7.E-03 ZR-95 L.T. 1.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 9.E-03 RU-1 03 L.T. 8.E-03 L.T. 6.E-02 L.T. 3.E-02 L.T. 8.E-03 RU-1 06 L.T. 2.E-02 L.T. 3.E-02 L.T. 3.E-02 L.T. 2.E-02 1-131 L.T. 5.E+00 L.T. 1.E+04 L.T. 1.E+02 L.T. 1.E+00 CS-134 L.T. 3.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 3.E-03 CS-137 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 2.E-03 BA-140 L.T. 9.E-01 L.T. 2.E+02 L.T. 9.E+00 L.T. 4.E-01 CE-141 L.T. 1.E-02 L.T. 1.E-01 L.T. 4.E-02 L.T. 1.E-02 CE-144 L.T. I.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 1.E-02 RA-226 L.T. 3.E-02 L.T. 5.E-02 L.T. 5.E-02 L.T. 4.E-02 TH-228 L.T. 3.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 4.E-03

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 10 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.53E-01 +/- 7.19E-02 2.27E-01 +/- 1.25E-01 1.66E-01 +/- 6.64E-02 1.13E-01 +/- 6.80E-02 K-40 L.T. 5.E-02 L.T. 4.E-02 L.T. 4.E-02 L.T. 6.E-02 MN-54 L.T. 4.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 5.E-03 CO-58 L.T. 6.E-03 L.T. 1.E-02 L.T. 6.E-03 L.T. 6.E-03 FE-59 L.T. 3.E-02 L.T. 9.E-02 L.T. 3.E-02 L.T. 2.E-02 CO-60 L.T. 4.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 4.E-03 ZN-65 L.T. 7.E-03 L.T. 9.E-03 L.T. 8.E-03 L.T. 8.E-03 ZR-95 L.T. 1.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 2.E-02 RU-1 03 L.T. 1.E-02 L.T. 4.E-02 L.T. 2.E-02 L.T. 1.E-02 RU-1 06 L.T. 3.E-02 L.T. 3.E-02 L.T. 3.E-02 L.T. 4.E-02 1-131 L.T. 7.E+00 L.T. 8.E+03 L.T. 1.E+02 L.T. 2.E+00 CS-1 34 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 5.E-03 CS-137 L.T. 3.E-03 L.T. 2.E-03 LT. 2.E-03 L.T. 3.E-03 BA-140 L.T. 2.E+00 L.T. 1.E+02 L.T. 7.E+00 L.T. 6.E-01 CE-141 L.T. 2.E-02 L.T. 9.E-02 L.T. 3.E-02 L.T. 2.E-02 CE-144 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 RA-226 L.T. 5.E-02 L.T. 4.E-02 L.T. 4.E-02 L.T. 7.E-02 TH-228 L.T. 5.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 7.E-03

VII-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION FISH (PCI/KG WET)

STATION NUMBER 28 DATE COLLECTED 07/13/09 07/13/09 09/15/09 09/15/09 CATFISH CARP CATFISH CARP GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 9.E+02 L.T. 8.E+02 L.T. 3.E+02 L.T. 3.E+02 K-40 3.86E+03 +/- 1.07E+03 2.89E+03 +/- 8.91E+02 3.17E+03 +/- 6.99E+02 2.92E+03 +/- 5.39E+02 MN-54 L.T. i.E+02 L.T. 6.E+01 L.T. 3.E+01 L.T. 3.E+01

.. CO-58 L.T. 9.E+01 L.T. 7.E+01 L.T. 4.E+01 L.T. 3.E+01 FE-59 L.T. 2.E+02 L.T. 1.E+02 L.T. 1.E+02 L.T. 8.E+01 CO-60 L.T. i.E+02 L.T. 6.E+01 L.T. 3.E+01 L.T. 4.E+01 ZN-65 L.T. 2.E+02 L.T. 1.E+02 L.T. 8.E+01 L.T. 8.E+01 ZR-95 L.T. 2.E+02 L.T. 1.E+02 L.T. 8.E+01 L.T. 6.E+01 RU-1 03 L.T. 1.E+02 L.T. 9.E+01 L.T. 5.E+01 L.T. 4.E+01 RU-1 06 L.T. 8.E+02 L.T. 5.E+02 L.T. 3.E+02 L.T. 3.E+02 1-131 L.T. 2.E+03 L.T. 1.E+03 L.T. 2.E+02 L.T. 1.E+02 CS-1 34 L.T. 7.E+01 L.T. 6.E+01 L.T. 4.E+01 L.T. 3.E+01 CS-1 37 L.T. 8.E+01 L.T. 6.E+01 L.T. 4.E+01 L.T. 3.E+01 BA-140 L.T. 2.E+03 L.T. 1.E+03 L.T. 3.E+02 L.T.. 3.E+02 CE-141 L.T. 3.E+02 L.T. 3.E+02 L.T. 9.E+01 L.T. 5.E+01 CE-144 L.T. 8.E+02 L.T. 5.E+02 L.T. 3.E+02 L.T. 2.E+02 RA-226 L.T. 2.E+03 L.T. 2.E+03 L.T. 1.E+03 L.T. 7.E+02 TH-228 L.T. 2.E+02 L.T. 1.E+02 L.T. 8.E+01 L.T. 6.E+01

VII-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION FISH (PCI/KG WET)

STATION NUMBER 35 DATE COLLECTED 07/14/09 07/13/09 09/15/09 09/15/09 CATFISH CARP CATFISH CARP GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 6.E+02 L.T. 6.E+02 L.T. 4.E+02 L.T. 4.E+02 K-40 2.79E+03 +/- 7.03E+02 3.18E+03 i 6.73E+02 3.55E+03 +/- 6.32E+02 2.81E+03 +/- 6.68E+02 MN-54 L.T. 6.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 4.E+01 CO-58 L.T. 6.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 4.E+01 FE-59 L.T. 2.E+02 L.T. 2.E+02 L.T. 1.E+02 L.T. 9.E+01 CO-60 L.T. 6.E+01 L.T. 5.E+01 L.T. 3.E+01 L.T. 4.E+01 ZN-65 L.T. 1.E+02 L.T. 1.E+02 L.T. 1.E+02 L.T. 9.E+01 ZR-95 L.T. 2.E+02 L.T. 1.E+02 L.T. 8.E+01 L.T. 8.E+01 RU-1 03 L.T. 1.E+02 L.T. 9.E+01 L.T. 5.E+01 L.T. 5.E+01 RU-1 06 L.T. 5.E+02 L.T. 4.E+02 L.T. 4.E+02 L.T. 4.E+02 1-131 L.T. 1.E+03 L.T. 1.E+03 L.T. 2.E+02 L.T. 1.E+02 CS-1 34 L.T. 4.E+01 L.T. 5.E+01 L.T. 5.E+01 L.T. 4.E+01 CS-1 37 L.T. 6.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 4.E+01 BA-140 L.T. 1.E+03 L.T. 1.E+03 L.T. 3.E+02 L.T. 3.E+02 CE-141 L.T. 2.E+02 L.T. 1.E+02 L.T. 7.E+01 L.T. 7.E+01 CE-144 L.T. 5.E+02 L.T. 3.E+02 L.T. 2.E+02 L.T. 2.E+02 RA-226 L.T. 1.E+03 L.T. 9.E+02 L.T. 9.E+02 L.T. 8.E+02 TH-228 L.T. 1.E+02 L.T. 8.E+01 L.T. 8.E+01 L.T. 6.E+01

VII-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 99 DATE COLLECTED 01/06/09 02/03/09 03/03/09 04/07/09 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 5.E-01 L.T. 9.E-01 L.T. 8.E-01 L.T. 8.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 4.E+01 L.T. 5.E+01 L.T. 5.E+01 L.T. 4.E+01 K-40 1.27E+03 +/- 1.05E+02 1.29E+03 +/- 1.11E+02 1.28E+03 +/- 1.20E+02 1.17E+03 +/- 1.04E+02 MN-54 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 CO-58 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 FE-59 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 CO-60 L.T. 4.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 ZN-65 L.T. 1.E+01 L.T. 9.E+00 L.T. 1.E+01 L.T. 1.E+01 ZR-95 L.T. 9.E+00 L.T. 9.E+00 L.T. 9.E+00 L.T. 9.E+00 RU-1 03 L.T. 5.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 6.E+00 RU-106 L.T. 4.E+01 L.T. 4.E+01 L.T. 5.E+01 L.T. 4.E+01 1-131 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+01 CS-1 34 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 CS-137 L.T. 4.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 BA-140 L.T. 3.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 3.E+01 CE-141 L.T. 9.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 CE-144 L.T. 3.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 3.E+01 RA-226 L.T. 8.E+01 L.T. 1.E+02 L.T. 1.E+02 L.T. 1.E+02 TH-228 L.T. 7.E+00 L.T. 9.E+00 L.T. 1.E+01 L.T. 7.E+00

VII-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 99 /

DATE COLLECTED 05/05/09 06/02/09 06/23/09 07/07/09 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 4.E-01 L.T. 7.E-01 L.T. 8.E-01 L-T. 2-E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 3.E+01 L.T. 5.E+01 L.T. 5.E+01 L.T. 2.E+01 K-40 1.14E+03 +/- 5.E+01 1.46E+03 +/- 1.E+02 1.10E+03 +/- 1.E+02 1.23E+03 +/- 6.E+01 MN-54 L.T. 2.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 2.E+00 CO-58 L.T. 3.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+00 FE-59 L.T. 8.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 7.E+00 CO-60 L.T. 2.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 ZN-65 L.T. 5.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 6.E+00 ZR-95 L.T. 5.E+00 L.T. 8.E+00 L.T. 9.E+00 L.T. 5.E+00 RU-103 L.T. 4.E+00 L.T. 5.E+00 L.T. 6.E+00 L.T. 3.E+00 RU-106 L.T. 2.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 2.E+01 1-131 L.T. 4.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 9.E+00 CS-1 34 L.T. 2.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+00 CS-1 37 L.T. 2.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 BA-140 L.T. 5.E+01 L.T. 2.E+01 L.T. 3.E+01 L.T. 2.E+01 CE-141 L.T. 7.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 5.E+00 CE-144 L.T. 2.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 2.E+01 RA-226 L.T. 5.E+01 L.T. 1.E+02 L.T. 1.E+02 L.T. 5.E+01 TH-228 L.T. 3.E+00 1.36E+01 +/- 8.76E+00 L.T. 9.E+00 L.T. 4.E+00

VII-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 99 DATE COLLECTED 07/28/09 08/04/09 08/25/09 09/01/09 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 7.E-01 L.T. 5.E-01 L.T. 8.E-01 L.T. 5.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 5.E+01 L.T. 4.E+01 L.T. 7.E+01 L.T. 6.E+01 K-40 1.14E+03 +/- 1.12E+02 1.23E+03 +/- 1.27E+02 1.48E+03 +/- 1.91E+02 1.07E+03 +/- 1.43E+02 MN-54 L.T. 5.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. 7.E+00 CO-58 L.T. 6.E+00 L.T. 5.E+00 L.T. 8.E+00 L.T. 7.E+00 FE-59 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 CO-60 L.T. 6.E+00 L.T. 4.E+00 L.T. 6.E+00 L.T. 7.E+00 ZN-65 L.T. 1.E+01 L.T. 8.E+00 L.T. 2.E+01 L.T. 1.E+01 ZR-95 L.T. 1.E+01 L.T. 8.E+00 L.T. 1.E+01 L.T. 1.E+01 RU-1 03 L.T. 7.E+00 L.T. 5.E+00 L.T. 8.E+00 L.T. 7.E+00 RU-1 06 L.T. 5.E+01 L.T. 4.E+01 L.T. 6.E+01 L.T. 6.E+01 1-131 L.T. 3.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 CS-1 34 L.T. 5.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 6.E+00 CS-1 37 L.T. 5.E+00 L.T. 5.E+00 L.T. 7.E+00 L.T. 6.E+00 BA-140 L.T. 5.E+01 L.T. 3.E+01 L.T. 4.E+01 L.T. 4.E+01 CE-141 L.T. 1.E+01 L.T. 9.E+00 L.T. 1.E+01 L.T. 1.E+01 CE-144 L.T. 3.E+01 L.T. 3.E+01 L.T. 6.E+01 L.T. 5.E+01 RA-226 L.T. 1.E+02 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+02 TH-228 L.T. 9-E+00 L.T. 8.E+00 L.T. 2.E+01 L.T. 1.E+01

VII-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 99 DATE COLLECTED 09/22/09 10/06/09 11/03/09 12/10/09 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 6.E-01 L.T. 4.E-01 L.T. 6.E-01 L.T. 6.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 5.E+01 K-40 1.10E+03 +/- 1.30E+02 1.39E+03 +/- 1.03E+02 1.30E+03 +/- 8.39E+01 1.41 E+03 +/- 1.25E+02 MN-54 L.T. 7.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 5.E+00 CO-58 L.T. 7.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 5.E+00 FE-59 L.T. 1.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. i.E+01 CO-60 L.T. 7.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 6.E+00 ZN-65 L.T. 1.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 1.E+01 ZR-95 L.T. 1.E+01 L.T. 8.E+00 L.T. 6.E+00 L.T. 1.E+01 RU-103 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 6.E+00 RU-1 06 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 5.E+01 1-131 L.T. 1.E+01 L.T. 9.E+00 L.T. 6.E+00 L.T. 2.E+01 CS-1 34 L.T. 6.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 5.E+00 CS-1 37 L.T. 6.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 6.E+00 BA-140 L.T. 3.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 4.E+01 CE-141 L.T. 1.E+01 L.T. 8.E+00 L.T. 6.E+00 L.T. 1.E+01 CE-144 L.T. 5.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 4.E+01 RA-226 L.T. 2.E+02 L.T. 1.E+02 L.T. 8.E+01 L.T. i.E+02 TH-228 L.T. 1.E+01 L.T. 8.E+00 L.T. 6.E+00 L.T. 1.E+01

VII-5 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK OTHER PRODUCERS (PCI/LITER)

STATION NUMBER 103 DATE COLLECTED 01/06/09 04/07/09 07/07/09 10/06/09 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 6.E-01 L.T. 8.E-01 L.T. 2.E-01 L.T. 4.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 5.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 K-40 1.43E+03 +/- 1.31 E+02 1.17E+03 +/- 1.22E+02 1.28E+03 +/- 9.72E+01 1.19E+03 +/- 9.42E+01 MN-54 L.T. 5.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 CO-58 L.T. 6.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 FE-59 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 CO-60 L.T. 6.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 5.E+00 ZN-65 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 1.E+01 ZR-95 L.T. 9.E+00 L.T. 9.E+00 L.T. 8.E+00 L.T. 8.E+00 RU-103 L.T. 6.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 4.E+00 RU-1 06 L.T. 4.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 4.E+01 1-131 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 8.E+00 CS-1 34 L.T. 5.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 CS-1 37 L.T. 6.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 4.E+00 BA-140 L.T. 4.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 2.E+01 CE-141 L.T: 1.E+01 L.T. 1.E+01 L.T. 7.E+00 L.T. 8.E+00 CE-144 L.T. 4.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 3.E+01 RA-226 L.T. 1.E+02 L.T. 1.E+02 L.T. i.E+02 L.T. 1.E+02 TH-228 L.T. 8.E+00 L.T. 8.E+00 L.T. 7.E+00 L.T. 8.E+00

VII-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 11 DATE COLLECTED 01/20/09 02/10/09 03/10/09 04/14/09 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 7.E-01 L.T. 7.E-01 L.T. 4.E-01 L.T. 1.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 3.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 3.E+01 K-40 L.T. 4.E+01 L.T. 9.E+01 L.T. 3.E+01 L.T. 9.E+01 MN-54 L.T. 3.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 CO-58 L.T. 3.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 4.E+00 FE-59 L.T. 7.E+00 L.T. 9.E+00 L.T. 8.E+00 L.T. 9.E+00 CO-60 L.T. 3.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 4.E+00 ZN-65 L.T. 5.E+00 L.T. 8.E+00 L.T. 7.E+00 L.T. 8.E+00 ZR-95 L.T. 6.E+00 L.T. 9.E+00 L.T. 8.E+00 L.T. 8.E+00 RU-1 03 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 RU-1 06 L.T. 3.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 3.E+01 1-131 L.T. 2.E+01 L.T. 2.E+01 L.T. 8.E+00 L.T. 2.E+01 CS-1 34 L.T. 3.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 CS-137 L.T. 3.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 BA-140 L.T. 3.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 4.E+01 CE-141 L.T. 8.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 8.E+00 CE-144 L.T. 2.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 3.E+01 RA-226 L.T. 8.E+01 L.T. 1.E+02 L.T. 1.E+02 L.T. 8.E+01 TH-228 L.T. 7.E+00 L.T. 9.E+00 L.T. 8.E+00 L.T. 5.E+00 H-3 L.T. 3.E+02 L.T. 3.E+02 L.T. 3.E+02 L.T. 4.E+02

VII-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 11 DATE COLLECTED 05/12/09 07/21/09 10/20/09 (a)

RADIOCHEMICAL ANALYSIS:

1-131 L.T. 6.E-01 L.T. 8.E-01 L.T. 9.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 1.E+01 L.T. 4.E+01 L.T. 4.E+01

"-- K-40 L.T. 2.E+01 L.T. 8.E+01 L.T. 3.E+01 00 MN-54 L.T. 1.E+00 L.T. 5.E+00 L.T. 4.E+00 CO-58 L.T. 2.E+00 L.T. 5.E+00 L.T. 4.E+00 FE-59 L.T. 3.E+00 L.T. 1.E+01 L.T. 9.E+00 CO-60 L.T. 1.E+00 L.T. 4.E+00 L.T. 4.E+00 ZN-65 L.T. 3.E+00 L.T. 9.E+00 L.T. 1.E+01 ZR-95 L.T. 3.E+00 L.T. 9.E+00 L.T. 6.E+00 RU-103 L.T. 2.E+00 L.T. 5.E+00 L.T. 5.E+00 RU-106 L.T. 1.E+01 L.T. 4.E+01 L.T. 4.E+01 1-131 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 CS-134 L.T. 1.E+00 L.T. 4.E+00 L.T. 4.E+00 CS-137 L.T. 1.E+00 L.T. 4.E+00 L.T. 5.E+00 BA-140 L.T. 2.E+01 L.T. 3.E+01 L.T. 2.E+01 CE-141 L.T. 4.E+00 L.T. 8.E+00 L.T. 1.E+01 CE-144 L.T. 1.E+01 L.T. 3.E+01 L.T. 4.E+01 RA-226 L.T. 4.E+01 L.T. 9.E+01 L.T. 1.E+02 TH-228 L.T. 2.E+00 L.T. 8.E+00 L.T. 7.E+00 H-3 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+02 (a) Monthly sampling was changed to the ODAM required quarterly sampling schedule of Jan, April, July and October.

VII-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER-GROUND (PCI/LITER)

STATION NUMBER 47 DATE COLLECTED 01/20/09 02/10/09 03/11/09 04/14/09 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 6.E-01 L.T. 6.E-01 L.T. 3.E-01 LT. 9-E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 4.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 4.E+01 K-40 L.T. 3.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 7.E+01 MN-54 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 CO-58 L.T. 5.E+00 L.T.. 5.E+00 L.T. 5.E+00 L.T. 4.E+00 FE-59 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 7.E+00 CO-60 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 ZN-65 L.T. 8.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 6.E+00 ZR-95 L.T. 8.E+00 L.T. 9.E+00 L.T. 8.E+00 L.T. 7.E+00 RU-1 03 L.T. 5.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 5.E+00 RU-1 06 L.T. 3.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 1-131 L.T. 3.E+01 L.T. 2.E+01 L.T. 8.E+00 L.T. 2.E+01 CS-1 34 L.T. 3.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 CS-1 37 L.T. 4.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 4.E+00 BA-140 L.T. 4.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 3.E+01 CE-141 L.T. 1.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 9.E+00 CE-144 L.T. 3.E+01 L.T. 3.E+01 L.T. 4.E+01 L.T. 3.E+01 RA-226 L.T. 1.E+02 L.T. 1.E+02 L.T. 1.E+02 L.T. 9.E+01 TH-228 L.T. 7-E+00 L.T. 1.E+01 L.T. 9-E+00 L.T. 6.E+00 H-3 L.T. 3.E+02 L.T. 3.E+02 L.T. 3.E+02 L.T. 4.E+02

VII-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 47 DATE COLLECTED 05/12/09 07/22/09 10/20/09 (a)

RADIOCHEMICAL ANALYSIS:

1-131 L.T. 7.E-01 L.T. 7.E-01 L.T. 9.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 6.E+01 00 K-40 L.T. 3.E+01 L.T. 2.E+01 L.T. 5.E+01 0 MN-54 L.T. 2.E+00 L.T. 3.E+00 L.T. 6.E+00 CO-58 L.T. 2.E+00 L.T. 2.E+00 L.T. 7.E+00 FE-59 L.T. 5.E+00 L.T. 5.E+00 L.T. 1.E+01 CO-60 L.T. 2.E+00 L.T. 3.E+00 L.T. 6.E+00 ZN-65 L.T. 4.E+00 L.T. 5.E+00 L.T. 1.E+01 ZR-95 L.T. 4.E+00 L.T. 5.E+00 L.T. 1.E+01 RU-103 L.T. 2.E+00 L.T. 3.E+00 L.T. 7.E+00 RU-106 L.T. 2.E+01 L.T. 2.E+01 L.T. 6.E+01 1-131 L.T. 1.E+01 L.T. 8.E+00 L.T. 1.E+01 CS-134 L.T. 2.E+00 L.T. 3.E+00 L.T. 6.E+00 CS-137 L.T. 2.E+00 L.T. 3.E+00 L.T. 7.E+00 BA-140 L.T. 2.E+01 L.T. 2.E+01 L.T. 3.E+01 CE-141 L.T. 5.E+00 L.T. 5.E+00 L.T. 1.E+01 CE-144 L.T. 1.E+01 L.T. 2.E+01 L.T. 5.E+01 RA-226 L.T. 4.E+01 L.T. 7.E+01 L.T. 2.E+02 TH-228 L.T. 3.E+00 L.T. 5.E+00 L.T. 1.E+01 H-3 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+02 (a) Monthly sampling was changed to the ODAM required quarterly sampling schedule of Jan, April, July and October.

VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 28 DATE COLLECTED 01/07/09 02/03/09 03/03/09 04/07/09 RADIOCHEMICAL ANALYSIS:

H-3 L.T. 3.E+02 L.T. 3.E+02 L.T. 3.E+02 L.T. 3.E+02 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 5.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 00 K-40 L.T. 9.E+01 L.T. 7.E+01 L.T. 4.E+01 L.T. 3.E+01 MN-54 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 CO-58 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 4.E+00 FE-59 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 7.E+00 CO-60 L.T. 5.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 ZN-65 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 7.E+00 ZR-95 L.T. 9.E+00 L.T. 1.E+01 L.T. 9.E+00 L.T. 5.E+00 RU-103 L.T. 6.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 4.E+00 RU-106 L.T. 4.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 1-131 L.T. 2.E+01 L.T. 2.E+01 L.T. 7.E+00 L.T. 1.E+01 CS-1 34 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 CS-137 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+00 BA-1 40 L.T. 3.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 2.E+01 CE-141 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 7.E+00 CE-144 L.T. 4.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 3.E+01 RA-226 L.T. 1.E+02 L.T. 1.E+02 L.T. 1.E+02 L.T. 9.E+01 TH-228 L.T. 1.E+01 L.T. 9.E+00 L.T. 9.E+00 L.T. 6.E+00

VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 28 DATE COLLECTED 05/05/09 06/02/09 07/07/09 08/03/09 RADIOCHEMICAL ANALYSIS:

H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 5.E+01 00 K-40 L.T. 3.E+01 L.T. 1.E+02 L.T. 6.E+01 L.T. 9.E+01 t')

MN-54 L.T. 2.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 4.E+00 CO-58 L.T. 2.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 5.E+00 FE-59 L.T. 5.E+00 L.T. 1.E+01 L.T. 7.E+00 L.T. 9.E+00 CO-60 L.T. 2.E+00 L.T. 7.E+00 L.T. 3.E+00 L.T. 4.E+00 ZN-65 L.T. 3.E+00 L.T. 9.E+00 L.T. 7.E+00 L.T. 8.E+00 ZR-95 L.T. 4.E+00 L.T. 8.E+00 L.T. 6.E+00 L.T. 9.E+00 RU-103 L.T. 3.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 6.E+00 RU-106 L.T. 2.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 4.E+01 1-131 L.T. 2.E+01 L.T. 1.E+01 L.T. 6.E+00 L.T. 2.E+01 CS-1 34 L.T. 2.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 CS-1 37 L.T. 2.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 BA-140 L.T. 3.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 4.E+01 CE-141 L.T. 5.E+00 L.T. 8.E+00 L.T. 7.E+00 L.T. 1.E+01 CE-144 L.T. 1.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 4.E+01 RA-226 L.T. 4.E+01 L.T. 1.E+02 L.T. 8.E+01 L.T. 1.E+02 TH-228 L.T. 3.E+00 L.T. 9.E+00 L.T. 9.E+00 L.T. 8.E+00

VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 28 DATE COLLECTED 09/01/09 10/06/09 11103/09 12/15/09 RADIOCHEMICAL ANALYSIS:

H-3 L.T. 2-E+02 L.T. 2-E+02 L.T. 2-E+02 L.T. 3.E+02 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 7.E+01 L.T. 3.E+01 L.T. 5.E+01 L.T. 9.E+00 00 K-40 L.T. 7.E+01 L.T. 8.E+01 L.T. 6.E+01 L.T. 5.E+00 MN-54 L.T. 7.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 8.E-01 CO-58 L.T. 7.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. 8.E-01 FE-59 L.T. 1.E+01 L.T. 9.E+00 L.T. 8.E+00 L.T. 2.E+00 CO-60 L.T. 8.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 6.E-01 ZN-65 L.T. 1.E+01 L.T. 8.E+00 L.T. 1.E+01 L.T. I.E+00 ZR-95 L.T. 1.E+01 L.T. 7.E+00 L.T. 1.E+01 L.T. 2.E+00 RU-103 L.T. 7.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. I.E+00 RU-106 L.T. 6.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 7.E+00 1-131 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 8.E+00 CS-134 L.T. 7.E+00 L.T. 3.E+00 L.T. 5.E+00 L.T. 7.E-01 CS-137 L.T. 7.E+00 L.T. 4.E+00 L.T. 6.EE+00 L.T. 7.E-01 BA-140 L.T. 4.E+01 L.T. 2.E+01 L.T. 4.E+01 L.T. 1.E+01 CE-141 L.T. 1.E+01 L.T. 7.E+00 L.T. 1.E+01 L.T. 2.E+00 CE-144 L.T. 5.E+01 L.T. 3.E+01 L.T. 5.E+01 L.T. 7.E+00 RA-226 L.T. 2.E+02 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+01 TH-228 L.T. 1.E+01 L.T. 7.E+00 L.T. 1.E+01 L.T. 2.E+00

VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 35 DATE COLLECTED 01/07/09 02/03/09 03/03/09 04/07/09 RADIOCHEMICAL ANALYSIS:

H-3 L.T. 2.E+02 L.T. 3.E+02 L.T. 3.E+02 L.T. 2.E+02 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 4.E+01 L.T. 5.E+01 L.T. 3.E+01 L.T. 4.E+01 oo K-40 L.T. 4.E+01 L.T. 5.E+01 L.T. 8.E+01 L.T. 4.E+01 MN-54 L.T. 4.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 CO-58 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 5.E+00 FE-59 L.T. 1.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 1.E+01 CO-60 L.T. 5.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 ZN-65 L.T. 9.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 9.E+00 ZR-95 L.T. 9.E+00 L.T. 9.E+00 L.T. 6.E+00 L.T. 8.E+00 RU-103 L.T. 6.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 6.E+00 RU-106 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 5.E+01 1-131 L.T. 1.E+01 L.T. 2.E+01 L.T. 6.E+00 L.T. 1.E+01 CS-1 34 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 4.E+00 CS-1 37 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 5.E+00 BA-140 L.T. 3.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 3.E+01 CE-141 L.T. 1.E+01 L.T. 9.E+00 L.T. 6.E+00 L.T. 1.E+01 CE-144 L.T. 3.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 4.E+01 RA-226 L.T. 1.E+02 L.T. 1.E+02 L.T. 9.E+01 L.T. 1.E+02 TH-228 L.T. 9.E+00 L.T. 9-E+00 L.T. 7-E+00 L.T. 9-E+00

VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 35 DATE COLLECTED 05/05/09 06/02/09 07/07/09 08/03/09 RADIOCHEMICAL ANALYSIS:

H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 7.E+01 L.T. 5.E+01 L.T. 4.E+01 00 K-40 L.T. 4.E+01 1.05E+02 +/- 6.31E+01 L.T. 6.E+01 L.T. 5.E+01 MN-54 L.T. 2.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 5.E+00 CO-58 L.T. 2.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 5.E+00 FE-59 L.T. 5.E+00 L.T. i.E+01 L.T. 9.E+00 L.T. i.E+01 CO-60 L.T. 2.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 ZN-65 L.T. 4.E+00 L.T. i.E+01 L.T. i.E+01 L.T. 9.E+00 ZR-95 L.T. 4.E+00 L.T. i.E+01 L.T. 9.E+00 L.T. 9.E+00 RU-103 L.T. 3.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 6.E+00 RU-106 L.T. 2.E+01 L.T. 6.E+01 L.T. 4.E+01 L.T. 4.E+01 1-131 L.T. 3.E+01 L.T. i.E+01 L.T. 9.E+00 L.T. 2.E+01 CS-1 34 L.T. 2.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 4.E+00 CS-1 37 L.T. 2.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 5.E+00 BA-140 L.T. 3.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 4.E+01 CE-141 L.T. 6.E+00 L.T. i.E+01 L.T. i.E+01 L.T. 1.E+01 CE-144 L.T. 2.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 RA-226 L.T. 5.E+01 L.T. 2.E+02 L.T. i.E+02 L.T. i.E+02 TH-228 L.T. 3.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00

VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 35 DATE COLLECTED 09/01/09 10/06/09 11/03/09 12/15/09 RADIOCHEMICAL ANALYSIS:

H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2-E+02 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 6.E+01 L.T. 3.E+01 L.T. 5.E+01 L.T. 8.E+00 00 K-40 1.89E+02 +/- 9.70E+01 L.T. 3.E+01 L.T. 1.E+02 L.T. 6.E+00 ON MN-54 L.T. 7.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 6.E-01 CO-58 L.T. 6.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 7.E-01 FE-59 L.T. 1.E+01 L.T. 8.E+00 L.T. 1.E+01 L.T. 2.E+00 CO-60 L.T. 6.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 7.E-01 ZN-65 L.T. 1.E+01 L.T. 7.E+00 L.T. 1.E+01 L.T. 1.E+00 ZR-95 L.T. 1.E+01 L.T. 5.E+00 L.T. 9.E+00 L.T. 1.E+00 RU-1 03 L.T. 8.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 1.E+00 RU-106 L.T. 6.E+01 L.T. 4.E+01 L.T. 5.E+01 L.T. 6.E+00 1-131 L.T. 2.E+01 L.T. 7.E+00 L.T. 2.E+01 L.T. 6.E+00 CS-1 34 L.T. 7.E+00 L.T. 3.E+00 L.T. 5.E+00 L.T. 6.E-01 CS-1 37 L.T. 6.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 7.E-01 BA-140 L.T. 4.E+01 L.T. 2.E+01 L.T. 4.E+01 L.T. 9.E+00 CE-141 L.T. 2.E+01 L.T. 7.E+00 L.T. 1.E+01 L.T. 2.E+00 CE-144 L.T. 6.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 5.E+00 RA-226 L.T. 2.E+02 L.T. 9.E+01 L.T. 1.E+02 L.T. 1.E+01 TH-228 L.T. 2-E+01 L.T. 61E+00 L.T. 8-E+00 5.36E+00 +/- 2.55E+00

VII-8 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD COOPER NUCLEAR STATION 2009 Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01/01-03/31 04/01-06/30 07/01-09/30 10/01-01/01 - 1 S.D.

TLD 01 24.8 +/- 0.7 21.5 +/- 0.4 21.4 +/- 0.6 20.5 +/- 0.3 22.0 +/- 1.9 02 23.9 +/- 0.7 20.7 +/- 0.2 20.7 +/- 0.2 20.6 +/- 0.7 21.5 +/- 1.6 03 23.7 +/- 0.9 20.9 +/- 0.1 22.1 +/- 0.6 23.1 +/- 0.2 22.4 +/- 1.2 04 23.7 +/- 0.7 21.7 +/- 0.7 21.9 +/- 0.5 19.4 +/- 0.1 21.7 +/- 1.7 05 21.2 +/- 0.4 23.0 +/- 0.8 21.3 +/- 1.5 21.0 +/- 0.2 21.6 +/- 1.0 06 24.7 +/- 0.6 20.9 +/- 0.8 22.4 +/- 0.3 22.0 +/- 0.4 22.5 +/- 1.6 07 23.1 +/- 0.5 23.6 +/- 1.1 21.0 +/- 0.3 22.4 +/- 0.3 22.5 +/- 1.1 08 24.3 +/- 0.3 22.5 +/- 2.1 21.2 +/- 0.7 23.5 +/- 1.3 22.9 +/- 1.3 09 23.5 +/- 0.8 20.2 +/- 1.6 22.1 +/- 0.3 21.8 +/- 0.1 21.9 +/- 1.3 10 21.2 +/- 0.2 22.4 +/- 1.6 23.1 +/- 2.0 22.0 +/- 0.4 22.2 +/- 0.8 20 22.5 +/- 0.1 21.5 +/- 1.0 22.1 +/- 1.1 22.8 +/- 0.1 22.2 +/- 0.5 44 25.5 +/- 0.4 23.7 +/- 0.7 22.8 +/- 0.7 24.8 +/- 0.6 24.2 +/- 1.2 56 24.9 +/- 1.2 23.4 +/- 0.8 22.6 +/- 1.9 22.1 +/- 0.7 23.3 +/- 1.2 58 20.8 +/- 0.1 22.3 +/- 0.3 22.1 +/- 0.8 22.4 +/- 0.4 21.9 +/- 0.8 59 22.3 +/- 0.4 20.9 +/- 0.9 21.6 +/- 0.3 23.0 +/- 1.0 22.0 +/- 0.9 66 22.9 +/- 0.03 22.8 +/- 1.2 24.1 +/- 0.5 23.7 +/- 1.1 23.4 +/- 0.6 67 23.2 +/- 1.2 22.2 +/- 0.2 23.3 +/- 1.3 23.1 +/- 0.3 22.9 +/- 0.5 71 21.7 +/- 0.7 25.6 +/- 0.8 21.5 +/- 0.5 21.1 +/- 0.5 22.5 +/- 2.1 79 22.6 +/- 0.1 25.6 +/- 2.0 22.0 +/- 0.6 23.5 +/- 0.0 23.4 +/- 1.6 80 24.6 +/- 0.8 26.9 +/- 1.0 21.2 +/- 0.5 22.9 +/- 1.1 23.9 +/- 2.4 81 22.8 +/- 1.4 25.5 +/- 0.7 23.3 +/- 0.2 23.2 +/- 0.2 23.7 +/- 1.2 82 22.5 +/- 0.9 24.7 +/- 1.7 22.5 +/- 0.5 22.3 +/- 0.7 23.0 +/- 1.1 83 25.0 +/- 0.5 25.9 +/- 1.3 22.6 +/- 0.5 25.4 +/-1.0 24.7 +/- 1.4 84 23.1 +/- 0.6 22.0 +/- 0.8 25.5 +/- 0.5 23.2 +/- 0.3 23.4 +/- 1.4 85 20.2 +/- 0.8 19.5 +/- 1.1 19.9 +/- 0.2 21.8 +/- 0.3 20.4 +/- 1.0

VII-8 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD COOPER NUCLEAR STATION 2009 Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01/01-03/31 04/01-06/30 07/01-09/30 10/01-01/01 - 1 S.D.

TLD 86 22.9 +/- 0.3 22.9 +/- 0.2 30.0 +/- 1.8 23.3 +/- 0.8 24.8 +/- 3.5 87 (a) 26.5 +/- 1.7 23.2 +/- 1.5 22.4 +/- 1.2 24.0 +/- 2.2 88 23.6 +/- 1.2 27.6 +/- 1.9 21.4 +/- 0.3 21.8 +/- 0.6 23.6 +/- 2.9 89 23.2 +/- 0.7 22.0 +/- 0.5 27.5 +/- 3.1 22.6 +/- 1.0 23.8 +/- 2.5 90 24.8 +/- 1.0 22.3 +/- 1.0 22.2 +/- 0.5 21.3 +/- 1.6 22.6 +/- 1.5 91 23.0 +/- 0.1 21.4 +/- 0.9 23.4 +/- 0.4 21.7 +/- 0.5 22.4 +/- 0.9 94 23.0 +/- 1.2 21.9 +/- 0.7 22.9 +/- 1.0 21.3 +/- 0.2 22.3 +/- 0.8 00 00 Average/Quarter 23.2 +/- 2.6 mrem/90 days 23.0 +/- 4.2 mrem/90 days 22.6 +/- 3.9 mrem/90 days 22.4 +/- 2.5 mrem/90 days Average/Day 0.258 +/- 0.03 mrem/day 0.255 +/- 0.05 mrem/day 0.252 +/- 0.04 mrem/day 0.249 +/- 0.03 mrem/day Range (20.2-25.5) mrem/90 days (19.5-27.6) mrem/90 days (19.9-30.0) mrem/90 days (19.4-25.4) mrem/90 days Detection/Total 31/31 32/32 32/32 32/32 25 7

32 (a) TLD was lost due to a farmer "incident".

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 28 DATE COLLECTED 05/27/09 06/11/09 07/30/09 08/11/09 (a) (a) (a) (a)

RADIOCHEMICAL ANALYSIS:

1-131 GAMMA SPECTRUM ANALYSIS:

BE-7 00 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No broadleaf vegetation available.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 28 DATE COLLECTED 09/29/09 10/27/09 (a) (a)

RADIOCHEMICAL ANALYSIS:

1-131 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 0MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-1 03 RU-1 06 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No broadleaf vegetation available.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 35 DATE COLLECTED 05/27/09 06/11/09 07/30/09 08/11/09 (a)

RADIOCHEMICAL ANALYSIS:

1-131 L.T. 4.E+01 L.T. 4.E+01 L.T. 4.E+01 GAMMA SPECTRUM ANALYSIS:

BE-7 6.55E+02 +/- 4.27E+01 1.02E+03 +/- 3.88E+02 6.24E+02 +/- 1.01E+02 K-40 4.99E+03 +/- 1.30E+02 4.03E+03 +/- 5.52E+02 6.74E+03 +/- 2.46E+02 MN-54 L.T. 4.E+00 L.T. 3.E+01 L.T. 9.E+00 CO-58 L.T. 5.E+00 L.T. 4.E+01 L.T. 9.E+00 FE-59 L.T. 1.E+01 L.T. 9.E+01 L.T. 2.E+01 CO-60 L.T. 4.E+00 L.T. 3.E+01 L.T. 9.E+00 ZN-65 L.T. 1.E+01 L.T. 8.E+01 L.T. 2.E+01 ZR-95 L.T. 8.E+00 L.T. 6.E+01 L.T. 2.E+01 RU-1 03 L.T. 5.E+00 L.T. 4.E+01 L.T. 1.E+01 RU-1 06 L.T. 4.E+01 L.T. 3.E+02 L.T. 8.E+01 1-131 L.T. 1.E+01 (b) L.T. 6.E+01 CS-1 34 L.T. 4.E+00 L.T. 3.E+01 L.T. 8.E+00 CS-137 L.T. 4.E+00 L.T. 3.E+01 L.T. 9.E+00 BA-140 L.T. 3.E+01 L.T. 4.E+02 L.T. 1.E+02 CE-141 L.T. 9.E+00 L.T. 6.E+01 L.T. 2.E+01 CE-144 L.T. 3.E+01 L.T. 2.E+02 L.T. 6.E+01 RA-226 L.T. 1.E+02 L.T. 6.E+02 L.T. 2.E+02 TH-228 1.22E+01 +/- 5.75E+00 LT. 5.E+01 2.33E+01 +/- 1.43E+01 (a) No broadleaf vegetation available.

(b) No gamma 1-131 reported for this sample.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 35 DATE COLLECTED 09/29/09 10/27/09 (a) (a)

RADIOCHEMICAL ANALYSIS:

1-131 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-1 06 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No broadleaf vegetation available.

-VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 96 DATE COLLECTED 05/27/09 06/11/09 07/30/09 08/11/09 (a) (a)

RADIOCHEMICAL ANALYSIS:

1-131 L.T. 3.E+01 L.T. 4.E+01 GAMMA SPECTRUM ANALYSIS:

BE-7 5.88E+02 +/- 2.14E+02 1.60E+03 +/- 1.E+02 K-40 7.09E+03 +/- 4.42E+02 6.21E+03 +/- 2.E+02 MN-54 L.T. 2.E+01 L.T. 9.E+00 CO-58 L.T. 2.E+01 L.T. 1.E+01 FE-59 L.T. 5.E+01 L.T. 3.E+01 CO-60 L.T. 2.E+01 L.T. 9.E+00 ZN-65 L.T. 4.E+01 L.T. 2.E+01 ZR-95 L.T. 3.E+01 L.T. 2.E+01 RU-103 L.T. 2.E+01 L.T. 1.E+01 RU-1 06 L.T. 1.E+02 L.T. 8.E+01 1-131 (b) L.T. 6.E+01 CS-1 34 L.T. 1.E+01 L.T. 9.E+00 CS-137 L.T. 2.E+01 L.T. 9.E+00 BA-140 L.T. 2.E+02 L.T. 1.E+02 CE-141 L.T. 4.E+01 L.T. 2.E+01 CE-144 L.T. 1.E+02 L.T. 6.E+01 RA-226 L.T. 3.E+02 L.T. 2.E+02 TH-228 3.15E+01 +/- 2.06E+01 L.T. 1.E+01 (a) No broadleaf vegetation available.

(b) No gamma 1-131 reported for this sample.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 96 DATE COLLECTED 09/29/09 10/27/09 (a) (a)

RADIOCHEMICAL ANALYSIS:

1-131 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-1 06 1-131 CS-1 34 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No broadleaf vegetation available.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 101 DATE COLLECTED 05/27/09 06/11/09 07/30/09 08/11/09 (a)

RADIOCHEMICAL ANALYSIS:

1-131 L.T. 4.E+01 L.T. 3_E+01 L.T. 5.E+01 GAMMA SPECTRUM ANALYSIS:

BE-7 1.53E+03 +/- 1.01E+02 2.73E+03 +/- 4.02E+02 6.84E+02 +/- 5.73E+01 K-40 5.16E+03 +/- 2.03E+02 2.58E+03 +/- 4.48E+02 5.93E+03 +/- 1.35E+02 MN-54 L.T. 8.E+00 L.T. 1.E+01 L.T. 5.E+00 CO-58 L.T. 8.E+00 L.T. 2.E+01 L.T. 6.E+00 FE-59 L.T. 2.E+01 L.T. 3.E+01 L.T. 1.E+01 CO-60 L.T. 9.E+00 L.T. 1.E+01 L.T. 5.E+00 ZN-65 L.T. 2.E+01 L.T. 3.E+01 L.T. 1.E+01 ZR-95 L.T. 2.E+01 L.T. 3.E+01 L.T. I.E+01 RU-1 03 L.T. 8.E+00 L.T. 2.E+01 L.T. 6.E+00 RU-1 06 L.T. 6.E+01 L.T. 1.E+02 L.T. 4.E+01 1-131 L.T. 2.E+01 (b) L.T. 3.E+01 CS-1 34 L.T. 7.E+00 L.T. 1.E+01 L.T. 4.E+00 CS-1 37 L.T. 8.E+00 L.T. 1.E+01 L.T. 5.E+00 BA-140 L.T. 5.E+01 L.T. 2.E+02 L.T. 5.E+01 CE-141 L.T. 1.E+01 L.T. 3.E+01 L.T. 1.E+01 CE-144 L.T. 5.E+01 L.T. 9.E+01 L.T. 3.E+01 RA-226 L.T. 2.E+02 L.T. 3.E+02 L.T. 1.E+02 TH-228 L.T. 1.E+01 9.09E+01 +/- 3.75E+01 L.T. 8.E+00 (a) No broadleaf vegetation available.

(b) No gamma 1-131 reported for this sample.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 101 DATE COLLECTED 09/29/09 10/27/09 (a) (a)

RADIOCHEMICAL ANALYSIS:

1-131 (LOW LVL)

GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-1 03 RU-1 06 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 TH-228 (a) No broadleaf vegetation available.

Vit-lo NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE SHORELINE SEDIMENT (PCI/KG DRY)

STATION NUMBER 28 DATE COLLECTED 05/27/09 10/20/09 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 6.E+02 L.T. 7.E+02 K-40 1.67E+04 +/- 1.20E+03 1.72E+04 +/- 1.31E+03 MN-54 L.T. 6.E+01 L.T. 5.E+01 CO-58 L.T. 6.E+01 L.T. 6.E+01 FE-59 L.T. 2.E+02 L.T. 2.E+02 CO-60 L.T. 5.E+01 L.T. 5.E+01 ZN-65 L.T. 1.E+02 L.T. 1.E+02 ZR-95 L.T. 1.E+02 L.T. 1.E+02 RU-1 03 L.T. 7.E+01 L.T. 8.E+01 RU-106 L.T. 5.E+02 L.T. 5.E+02 1-131 L.T. 6.E+02 L.T. 5.E+02 CS-1 34 L.T. 5.E+01 L.T. 5.E+01 CS-137 L.T. 6.E+01 L.T. 7.E+01 BA-140 L.T. 8.E+02 L.T. 8.E+02 CE-141 L.T. 1.E+02 L.T. 1.E+02 CE-144 L.T. 4.E+02 L.T. 4.E+02 RA-226 L.T. 1.E+03 2.08E+03 +/- 1.09E+03 TH-228 1.18E+03 +/- 9.09E+01 9.61E+02 +/- 1.1OE+02

VII-10 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE SHORELINE SEDIMENT (PCI/KG DRY)

STATION NUMBER 35 DATE COLLECTED 05/27/09 10/20/09 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 5.E+02 L.T. 4.E+02 K-40 1.39E+04 +/- 1.04E+03 1.14E+04 +/- 8.11E+02 MN-54 L.T. 4.E+01 L.T. 4.E+01 CO-58 L.T. 5.E+01 L.T. 4.E+01 FE-59 L.T. i.E+02 L.T. 9.E+01 00 CO-60 L.T. 5.E+01 L.T. 4.E+01 ZN-65 L.T. i.E+02 L.T. 8.E+01 ZR-95 L.T. 9.E+01 L.T. 8.E+01 RU-1 03 L.T. 6.E+01 L.T. 5.E+01 RU-106 L.T. 4.E+02 L.T. 3.E+02 1-131 L.T. 4.E+02 L.T. 3.E+02 CS-1 34 L.T. 4.E+01 L.T. 3.E+01 CS-1 37 L.T. 4.E+01 L.T. 4.E+01 BA-140 L.T. 6.E+02 L.T. 5.E+02 CE-141 L.T. i.E+02 L.T. 9.E+01 CE-144 L.T. 3.E+02 L.T. 2.E+02 RA-226 1.26E+03 +/- 8.01E+02 L.T. 7.E+02 TH-228 8.07E+02 +/- 7.49E+01 9.30E+02 +/- 6.10E+01

SECTION VIII. REFERENCES 99.

VIII. REFERENCES

1. Nebraska Public Power District, Cooper Nuclear Station Environmental Radiation Monitoring Program, Annual Report, January 1, 1982-December 31, 1982 (prepared by Teledyne Isotopes).
2. Nebraska Public Power District, Cooper Nuclear Station Environmental Radiation Monitoring Program, Annual Report, January 1, 1983-December 31, 1983 (prepared by Teledyne Isotopes).
3. Nebraska Public Power District Cooper Nuclear Station, Environmental Monitoring Program, Annual Report, January 1, 1984 to December 31, 1984. (Prepared by Teledyne Isotopes).
4. U.S. Department of Energy; EML 440 March 1985; EML-444 April 1989; Environmental Measurements Laboratory, US Department of Energy, New York, New York 10014.
5. U.S. Environmental Protection Agency; Environmental Radiation Data, Report 35, July -- September 1983, Report 39, July -- September 1985; Report 40, October --

December 1984; Report 41, January -- March 1985. Report 42, April -- June 1985; Report 43, July-September 1985, Report 44-45, October-March 1986; Report 46, April-June 1986; Report 47, July-September 1986; Report 48, October-December 1986; Report 49, January-March 1987. Environmental Radiation Facility, Montgomery, Alabama.

6. U.S. Department of Energy; EML 460, October 1, 1986; Environmental Measurements Laboratory, US Department of Energy, New York, New York 10014.
7. U.S. Nuclear Regulatory Commission, 1975, Regulatory Guide 4.8, Environmental Technical Specifications for Nuclear Power Plants.
8. U.S. Regulatory Commission, Branch Technical Position, Radiological Monitoring Acceptable Program (November, 1979, Revision 1).

100

APPENDIX A 2009 LAND USE CENSUS A-1

2009 LAND USE CENSUS Conducted July 8, 2009 0-3 miles Cooper Nuclear Station (CNS) Offsite Dose Assessment Manual (ODAM) requires an annual land use census. This census identifies the location of the nearest garden that is greater than 500 square feet in area and yields leafy green vegetables, the nearest milk animal, and the location of the nearest resident in each of the 16 meteorological sectors within 3 miles of CNS.

A land use census was performed on July 8, 2009, in accordance with the CNS ODAM. The nearest residence was found in sector Q, 0.9 miles from CNS, and the nearest garden was found in sector L, 1.3 miles from CNS.

No milk animals were found within 3 miles of CNS and there was no evidence of potable water use from the Missouri River within three miles of CNS.

A-2

2009 LAND USE CENSUS July 08, 2009 0-3 Miles SECTOR NEAREST RESIDENT Direction NEAREST GARDEN Direction NEAREST in Degrees in Degrees MILK Distance Distance ANIMAL A/N 2.5 Miles 1.00 NONE NA NONE B/NNE NONE NA NONE NA NONE C/NE 2.8 Miles 42.00 2.8 Miles 42.00 NONE D/ENE 1.7 Miles 62.00 1.7 Miles 62.00 NONE E/E 1.9 Miles 97.00 1.9 Miles 97.00 NONE F/ESE 2.3 Miles 112.00 3.0 Miles 108.00 NONE G/SE NONE NONE NONE NA NONE H/SSE NONE NA NONE NA NONE J/S NONE NA NONE NA NONE K/S SW 2.1 Miles 218.00 NONE NA NONE L/SW 1.3 Miles 232.00 1.3 Miles 232.00 NONE M/WSW 1.9 Miles 241.00 1.9 Miles 241.00 NONE N/W 1.0 Miles 265.00 NONE NA NONE P/WNW 1.7 Miles 299.00 2.4 Miles 298.00 NONE Q/NW 0.9 Miles 307.00 2.9 Miles 324.00 NONE R/NNW 1.9 Miles 339.00 2.8 Miles 335.00 NONE A-3

APPENDIX B

SUMMARY

OF INTERLABORATORY COMPARISONS The Teledyne Brown En2ineering ICP report is presented in this section B-1

INTERLABORA TORY COMPARISION PROGRAM The purpose of the Interlaboratory Comparison Program (ICP) is to confirm the accuracy of results produced by Teledyne Brown Engineering. Samples of various matrices (i.e. soil, water, vegetation, air filters, and milk) are spiked with known amounts of radioactivity by commercial vendors of this service and by departments within the government. TBE participates in three programs. Two are commercial, Analytics Inc.

and Environmental Resource Associates (ERA) and one is a government sponsored program, the Department of Energy's (DOE) Mixed Analyte Performance Evaluation Program (MAPEP). The DOE's Idaho National Engineering Laboratory administers the MAPEP. All three programs are blind performance evaluation studies in which samples with known activities are sent to TBE for analysis. Once analyzed, TBE submits the results to the respective agency for evaluation. The results of these evaluations are published in TBE's quarterly and annual QA reports.

The 2009 Interlaboratory Comparison Program includes all contractually required matrices and analyses we supply to customers.

The US Environmental Protection Agency (EPA) discontinued their Interlaboratory Comparison Program in December 1998. However, on May 1, 2001, accreditation was granted to Environmental Resource Associates' (ERA) RadCheM Proficiency Testing Program to complete the process of replacing the USEPA-LV Nuclear Radiation Assessment Division program.

The Department of Energy's Environmental Measurement Laboratory (EML) program terminated performance assessments at the end of the March 2004 test session.

The MAPEP sample distribution was expanded to include water, soil, vegetation and air particulate testing material previously provided by DOE/EML. In 2009, the samples were received in March and September with required reporting dates of May and October, respectively.

The National Institute of Standards and Technology (NIST) is the approval authority for laboratory providers participating in Intercomparison Study Programs; however, at this time, there are no approved laboratories for environmental and/or radiochemical isotope analyses.

Trending graphs are provided in this section for the Analytics and ERA Programs.

B-2

ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 3)

Identification Reported Known Ratio (c)

Month/Year Number Matrix Nuclide Units Value (a) Value (b) TBE/Analytics Evaluation (d)

March 2009 E6533-396 Milk Sr-89 pCi/L 102 97.7 1.04 A Sr-90 pCi/L 14.9 15.6 0.96 A E6534-396 Milk 1-131 pCi/L 66.7 79.3 0.84 A Ce-141 pCi/L 87.5 94.9 0.92 A Cr-51 pCi/L 275 305 0.90 A Cs-1 34 pCi/L 82.0 93.7 0.88 A Cs-1 37 pCi/L ill 111 1.00 A Co-58 pCi/L 114 119 0.96 A Mn-54 pCi/L 136 128 1.06 A Fe-59 pCi/L 112 99.9 1.12 A Zn-65 pCi/L 160 156 1.03 A Co-60 pCi/L 142 ,142 1.00 A E6536-396 AP Ce-141 pCi 120 115 1.04 A Cr-51 pCi 385 371 1.04 A Cs-i 34 pCi 113 114 0.99 A Cs-1 37 pCi 149 135 1.10 A Co-58 pCi 153 145 1.06 A Mn-54 pCi 155 155 1.00 A Fe-59 pCi 118 121 0.98 A.

Zn-65 pCi 195 189 1.03 A Co-60 pCi 190 173 1.10 A E6535-396 Charcoal 1-131 pCi 82.8 79.4 1.04 A June 2009 E6742-396 Milk Sr-89 pCi/L 107 112 0.96 A Sr-90 pCi/L 19.0 16.7 1.14 A E6743-396 Milk 1-131 pCi/L 98.1 102.0 0.96 A Ce-141 pCi/L 260 284 0.92 A Cr-51 pCi/L 389 400 0.97 A Cs-134 pCi/L 144.0 166 0.87 A Cs-1 37 pCi/L 185 192 0.96 A Co-58 pCi/L 86.9 91.9 0.95 A Mn-54 pCi/L 133 137 0.97 A Fe-59 pCi/L 126 122 1.03 A Zn-65 pCi/L 173 175 0.99 A Co-60 pCi/L 298 312 0.96 A E6745-396 AP Ce-141 pCi 186 163 1.14 A Cr-51 pCi 262 231 1.13 A Cs-1 34 pCi 101 95 1.06 A Cs-1 37 pCi 135 ill 1.22 W Co-58 pCi 61 53 1.16 A Mn-54 pCi 83.1 79 1.05 A Fe-59 pCi 84 70 1.19 A Zn-65 pCi 137 101 1.36 N (1)

Co-60 pCi 202 180 1.12 A E6744-396 Charcoal 1-131 pCi 92.2 95.8 0.96 A B-3

ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 2 OF 3)

Identification Reported Known Ratio (c)

Month/Year Number Matrix Nuclide Units Value (a) Value (b) TBE/Analytics Evaluation (d)

June 2009 E6745-396 Water Fe-55 pCi 1780 1790 0.99 September 2009 E6897-396 Milk Sr-89 pCi/L 113 107 1.06 Sr-90 pCi/L 17.4 18.8 0.93 E6898-396 Milk 1-131 pCi/L 89.2 98.6 0.90 Ce-141 pCi/L 249 275 0.91 Cr-51 pCi/L 213 221 0.96 Cs-1 34 pCi/L 104.0 123 0.85 Cs-1 37 pCi/L 172 185 0.93 Co-58 pCi/L 96.3 99.4 0.97 Mn-54 pCi/L 201 206 0.98 Fe-59 pCi/L 154 147 1.05 Zn-65 pCi/L 213 204 1.04 Co-60 pCi/L 154 160 0.96 E6900-396 AP Ce-141 pCi 181 161 1.12 Cr-51 pCi 145 130 1.12 Cs-134 pCi 71.8 72 0.99 Cs-137 pCi 115 109 1.06 Co-58 pCi 62 58 1.06 Mn-54 pCi 129 121 1.07 Fe-59 pCi 97 98 0.98 Zn-65 pCi 110 120 0.92 Co-60 pCi 98.7 94.1 1.05 E6899-396 Charcoal 1-131 pCi 89.5 92.3 0.97 E6901-396 Water Fe-55 pCi 1980 1980 1.00 A December 2009 E6946-396 Milk Sr-89 pCi/L 131 131 1.00 A Sr-90 pCi/L 19.3 17.9 1.08 A E6947-396 Milk 1-131 pCi/L 79.2 87.3 0.91 A Ce-141 pCi/L 193 202 0.96 A Cr-51 pCi/L 512 548 0.93 A Cs-134 pCi/L 222 253 0.88 A Cs-137 pCi/L 163 179 0.91 A Co-58 pCi/L 200 211 0.95 A Mn-54 pCi/L 178 178 1.00 A Fe-59 pCi/L 176 178 0.99 A Zn-65 pCi/L 326 345 0.94 A Co-60 pCi/L 240 256 0.94 A E6949-396 AP Ce-141 pCi 103 103. 1.00 A Cr-51 pCi 290 280 1.04 A Cs-134 pCi 116 129 0.90 A Cs-137 pCi 93.4 91.5 1.02 A Co-58 pCi ill 108 1.03 A Mn-54 pCi 81.0 90.8 0.89 A Fe-59 pCi 106 90.8 1.17 A Zn-65 pCi 155 176 0.88 A Co-60 pCi 135 131 1.03 A B-4

ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 3 OF 3)

Identification Reported Known Ratio (c)

Month/Year Number Matrix Nuclide Units Value (a) Value (b) TBE/Analytics Evaluation(d)

December 2009 E6948-396 Charcoal 1-131 pCi 93.3 93.9 0.99 A E6950-396 Water Fe-55 pCi 1860 2500 0.74 W (1) Detector 7 appears to have a slightly high bias. Detector 7 was removed from service until it can be recalibrated. NCR 09-23 (a) Teledyne Brown Engineeringreported result.

(b) The Analytics known value is equal to 100% of the parameterpresent in the standardas determined by gravimetricand/or volumetric measurements made during standardpreparation.

(c) Ratio of Teledyne Brown Engineering to Analytics results.

(d) Analytics evaluation based on TBE internal OC limits: A= Acceptable. Reported result falls within ratiolimits of 0.80-1.20.

W-Acceptable with warning. Reported result falls within 0. 70-0.80 or 1.20-1.30. N = Not Acceptable. Reported result falls outside the ratiolimits of < 0. 70 and > 1.30.

B-5

DOE's MIXED ANALYTE PERFORMANCE EVALUATION PROGRAM (MAPEP)

TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 3)

Identification Reported Known , Acceptance Month/Year Number Media Nuclide Units Value (a) Value (b) Range Evaluation (c)

March 2009 09-MaW20 Water Am-241 Bq/L NR Cs-1 34 Bq/L 18.8 22.5 18.5 - 29.3 A Cs-1 37 Bq/L 0.0601 (1) A Co-57 Bq/L 17.0 18.9 13.2 -24.6 A Co-60 Bq/L 16.1 17.21 12.05 - 22.37 A Fe-55 Bq/L 69.92 48.20 33.7 - 62.7 N (2)

H-3 Bq/L 332 330.9 231.6 - 430.2 A Mn-54 Bq/L 13.8 14.7 10.26 - 19.06 A Ni-63 Bq/L 50.7 53.50 37.45 - 69.55 A Pu-238 Bq/L 0.349 1.18 0.83-1.53 N (3)

Pu-239/240 Bq/L 0.244 0.853 0.597 - 1.109 N (3)

Sr-90 Bq/L 6.88 7.21 5.05- 9.37 A Tc-99 Bq/L 12.5 14.46 10.12- 18.80 A U-234/233 Bq/L 2.61 2.77 1.94 - 3.60 A U-238 Bq/L 2.71 2.88 2.02 - 3.74 A Zn-65 Bq/L 13.2 13.6 9.5- 17.7 A 09-GrW2O Water Gr-A Bq/L 0.529 0.635 >0.0 - 1.270 A Gr-B Bq/L 1.87 1.27 0.64-1.91 A 09-MaS20 Soil Am-241 Bq/kg 27.17 38.3 26.8 - 49.8 W Cs-1 34 Bq/kg 433 467 327 - 607 A Cs-1 37 Bq/kg 649 605 424 - 787 A Co-57 Bq/kg -0.120 (1) A Co-60 Bq/kg 3.91 4.113 (4) A Mn-54 Bq/kg 339 307 215-399 A Ni-63 Bq/kg 241 514.9 360.4 - 669.4 N (5)

Pu-238 Bq/kg NR Pu-239/240 Bq/kg NR K-40 Bq/kg 644 570 399 - 741 A Sr-90 Bq/kg 245 257 180 - 334 A Tc-99 Bq/kg 133 171 120-222 W U-234/233 Bq/kg 158.7 149 104- 194 A U-238 Bq/kg 164.8 155 109 - 202 A Zn-65 Bq/kg 272 242 169-315 A 09-RdF20 AP Am-241 Bq/sample NR Cs-1 34 Bq/sample 2.77 2.93 2.05 - 3.81 A Cs-1 37 Bq/sample 1.41 1.52 1.06- 1.98 A Co-57 Bq/sample 1.24 1.30 0.91 - 1.69 A Co-60 Bq/sample 1.33 1.22 0.85- 1.59 A Mn-54 Bq/sample 2.42 2.2709 1.5898 - 2.9522 A Pu-238 Bq/sample 0.0965 0.1763 0.1234 - 0.2292 N (6)

Pu-239/240 Bq/sample 0.084 0.157 0.110 - 0.204 N (6)

Sr-90 Bq/sample 0.713 0.64 0.448 - 0.832 A U-234/233 Bq/sample 0.187 0.198 0.139 - 0.257 A U-238 Bq/sample 0.183 0.21 0.15-0.27 A Zn-65 Bq/sample 1.30 1.36 0.95- 1.77 A 09-GrF20 AP Gr-A Bq/sample 0.188 0.348 >0.0 - 0.696 A Gr-B Bq/sample 0.313 0.279 0.140 - 0.419 A B-6

DOE's MIXED ANALYTE PERFORMANCE EVALUATION PROGRAM (MAPEP)

TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 2 OF 3)

Identification Reported Known Acceptance Month/Year Number Media Nuclide Units Value (a) Value (b) Ranae Evaluation (c)

March 2009 09-RdV20 Vegetation Cs-1 34 Bq/sample 3.48 3.40 2.38 - 4.42 A Cs-1 37 Bq/sample 1.15 0.93 0.65- 1.21 W Co-57 Bq/sample 3.12 2.36 1.65 - 3.07 N (7)

Co-60 Bq/sample -0.0105 (1) A Mn-54 Bq/sample 2.98 2.3 1.61 -2.99 W K-40 Bq/sample 64.1 (8)

Sr-90 Bq/sample 1.09 1.260 0.882 - 1.638 A Zn-65 Bq/sample 1.73 1.3540 0.948 - 1.760 W September 2009 09-MaW21 Water Cs-1 34 Bq/L 26.5 32.2 22.5 - 41.9 A Cs-1 37 Bq/L 37.2 41.2 28.8 - 53.6 A Co-57 Bq/L 32.2 36.6 25.6 - 47.6 A Co-60 Bq/L 14.0 15.40 10.8- 20.0 A H-3 Bq/L 705 634.1 443.9 - 824.3 A Mn-54 Bq/L -0.1015 (1) A Ni-63 Bq/L 40.93 44.2 30.9 - 57.5 A Pu-238 Bq/L 0.008 0.018 (4) A Pu-239/240 Bq/L 1.507 1.640 1.15-2.13 A Sr-90 Bq/L 13.9 12.99 9.09- 16.89 A Tc-99 Bq/L 8.06 10.0 7.0- 13.0 A U-234/233 Bq/L 3.01 2.96 2.07 - 3.85 A U-238 Bq/L 3.07 3.03 3.07 - 3.94 A Zn-65 Bq/L 26.2 26.9 18.8- 35.0 A 09-GrW21 Water Gr-A Bq/L 1.27 1.047 >0.0 - 2.094 A Gr-B Bq/L 9.70 7.53 3.77 - 11.30 A 09-MaS21 Soil Am-241 Bq/kg 74.7 89.8 62.9 - 116.7 A Cs-1 34 Bq/kg 0.554 (1) A Cs- 137 Bq/kg 706 669 468 - 870 A Co-57 Bq/kg 606 586 410-762 A Co-60 Bq/kg 350 327.000 229-425 A Mn-54 Bq/kg 876 796 557-1035 A Ni-63 Bq/kg 509 680.0 476 - 884 W K-40 Bq/kg 425 375 263-488 A Sr-90 Bq/kg 505 455 319-592 A Tc-99 Bq/kg 392 444 311 -577 A U-234/233 Bq/kg 219 209 146-272 A U-238 Bq/kg 211 217 152-282 A Zn-65 Bq/kg 1370 1178 825-1531 A 09-RdF21 AP Am-241 Bq/sample -0.0040 (1) A Cs-134 Bq/sample -0.02 (1) A Cs-137 Bq/sample 1.4 1.4 0.98- 1.82 A Co-57 Bq/sample 5.98 6.48 4.54 - 8.42 A Co-60 Bq/sample 1.01 1.03 0.72-1.34 A Mn-54 Bq/sample 5.16 5.49 3.84 - 7.14 A Pu-238 Bq/sample 0.0745 0.091 0.064 - 0.118 A Pu-239/240 Bq/sample 0.1100 0.138 0.097 - 0.0471 W Sr-90 Bq/sample 0.925 0.0835 0.585 - 1.086 A U-234/233 Bq/sample 0.276 0.300 0.210 - 0.390 A U-238 Bq/sample 0.312 0.312 0.218 - 0.406 A Zn-65 Bq/sample 4.39 3.93 2.75-5.11 A B-7

DOE's MIXED ANALYTE PERFORMANCE EVALUATION PROGRAM (MAPEP)

TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 3 OF 3)

Identification Reported Known Acceptance Month/Year Number Media Nuclide Units Value (a) Value (b) Range Evaluation (c)

September 2009 09-GrF21 AP Gr-A Bq/sample 0.357 0.659 >0.0 - 1.318 A Gr-B Bq/sample 1.403 1.320 0.66- 1.98 A 09-RdV21 Vegetation Cs-134 Bq/sample -0.0027 (1) A Cs-137 Bq/sample 2.36 2.43 1.70-3.16 A Co-60 Bq/sample 2.58 2.57 1.80 - 3.34 A Mn-54 Bq/sample 8.36 7.9 5.5- 10.3 A K-40 Bq/sample 57.8 (8)

Sr-90 Bq/sample 1.73 1.78 1.25-2.31 A Zn-65 Bq/sample -0.59 (1) A (1) Falsepositive test.

(2) Fe-55 activity is too close to our detection limit. Fe-55 in water will be done quarterlythrough Analytics from now on. NCR 09-10 (3) Resin problem caused failure. NCR 09-11 (4) Sensativity evaluation.

(5) Abnormally high concentration of native nickel in soil caused high recovery resulting in low activity. NCR 09-09 (6) Resin problem caused failure. NCR 09-12 (7) Homogeniety problem. MAPEP requires using entire sample but due to geometry limitations we can only use part of the sample. NCR 09-13 (8) Not evaluated by MAPEP.

(a) Teledyne Brown Engineeringreportedresult.

(b) The MAPEP known value is equal to 100% of the parameterpresent in the standardas determined by gravimetric and/or volumetric measurements made during standardpreparation.

(c) DOEIMAPEPevaluation: A=acceptable, W=acceptablewith warning, N=not acceptable.

B-8

ERA ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 1)

Identification Reported Known Month/Year Number Media Nuclide Units Value (a) Value (b) Control Limits Evaluation (c)

April 2009 RAD 77 Water Sr-89 pCi/L 57.4 48.3 37.8 - 55.7 N (1)

Sr-90 pCi/L 30.6 31.4 22.9 - 36.4 A Ba-1 33 pCi/L 55.2 52.7 43.4 - 58.3 A Cs-134 pCi/L 65.8 72.9 59.5 - 80.2 A Cs-1 37 pCi/L 157 168 151 -187 A Co-60 pCi/L 86.4 88.9 80.0- 100 A Zn-65 pCi/L '85.5 84.4 76.0- 101 A Gr-A pCi/L 47.7 54.2 28.3 - 67.7 A Gr-B pCi/L 45.2 43.5 29.1 - 50.8 A 1-131 pCi/L 25.2 26.1 21.7 - 30.8 A U-Nat pCi/L 24.0 25.7 20.6 - 28.8 A H-3 pCi/L 19733 20300 17800 - 22300 A October 2009 RAD 79 Water Sr-89 pCi/L 64.75 62.2 50.2 - 70.1 A Sr-90 pCi/L 30.30 30.7 22.4 - 35.6 A Ba-1 33 pCi/L 97.9 92.9 78.3-102 A Cs-1 34 pCi/L 76.8 79.4 65.0 - 87.3 A Cs-1 37 pCi/L 59.9 54.6 49.1 - 62.9 A Co-60 pCi/L 121 117 105-131 A Zn-65 pCi/L 115 99.5 89.6-119 A Gr-A pCi/L 19.6 23.2 11.6-31.1 A Gr-B pCi/L 28.5 26.0 16.2 - 33.9 A 1-131 pCi/L 22.1 22.2 18.4-26.5 A H-3 pCi/L 16133 16400 14300 - 18000 A (1) Calculationdid not allow for Y-90 ingrowth on the Sr-89 mount. NCR 09-14 (a) Teledyne Brown Engineeringreportedresult.

(b) The ERA known value is equal to 100% of the parameterpresent in the standardas determinedby gravimetric and/or volumetric measurements made duringýstandardpreparation.

(c) ERA evaluation:A=acceptable. Reported result falls within the Warning Limits. NA=not acceptable. Reported result falls outside of the ControlLimits. CE=check for Error. Reportedresult falls within the ControlLimits and outside of the Warning Limit.

B-9

1-131 IN MILK 120 100 , U i A.m" *! 1 . !h I.- 80

-J 60 UU C,

0. 40 20 p 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10

  • TBE iAnalytics Ce-141 IN MILK 1000 800 600 400 =

200 *a3 * *'** Io

  • 0 1 1a ,

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10

  • TBE @Analyt:ics Cr-51 IN MILK 1200 1000 800

. 600 p aL 400 ** pa - p'* see p 200 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10

[ TBE *Analytics B-1O

Cs-134 IN MILK 300 225 -

150- E j Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I -TBE mAnalytics I Cs-137 IN MILK 350 300 E 250 I 200 i -

150O 50 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-i0 I ATBE,Analytics I Mn-54 IN MILK 240 200 un

16o~ u.*

III . U.:-el T=

.120 - * -

80

  • I 40 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE iAnalytics I B-I1

Fe-59 IN MILK 200 180 160 140

+120 100 m -

% 80 *  := - . E.

60 PU 40 a 20 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10

  • TBE SAnalytics Zn-65 IN MILK 400 350 300

. 250 200 nor*aI 100 50 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I -TBE IIAnalyties Co-60 IN MILK 400 350 m 300 250 I *

.200 100 !l1 50 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-i0 I OTBE ,Analytics I B-12

Sr-90 IN MILK 80 60

~40

, s. e go 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 3Analytics OTBE Co-58 in Milk 240 200

  • 160 t-_ 12 a a 80 we sip, 4800 a 40 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10
  • TB m~a yics Sr-89 IN MILK 200 180 160 140 120 100 E 080 S 0.-60 40 20 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I*TBE MAnalyticsI B-13

Ce-141 IN FILTERS 690 590 490 C, 390

  • 290 "190
  • d i i.

-- I _ . * *

-10 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE iAnalytics Cr-51 IN FILTERS 890 790 690 590

0. 490 3 390 'l S290 .

190 -

90

-10 ,,

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE UAnalytics I Cs-134 IN FILTERS 170 150 130

0. 90 170 # - .1*

0- 50 30 10

-10 U Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE mAnalytics B-14

Cs-137 IN FILTERS 440

  • -290 g 140 , p a sa -Be

-10 1 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I#TBE Analytics Mn-54 IN FILTERS 190 150 m a.

U *

(U 1Oo 0.

"'U. _pS U EI Ii .= l -*ai U U

0 30

-10 U Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 TBE An cs I

Fe-59 IN FILTERS 190 170 150 130 110 * .

0.90 .

a a 70 a m wpo 10

-10 U

-10 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE ,Analytics I B-15

Zn-65 IN FILTERS 290 240 1i90 140 -a-

  • a.e . . "m o 90
  • p 40

-10 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-i0 I *TBE mAnalytics I Co-60 IN FILTERS 290 240 190

  • 0R-- *90--e w m i 40

-10 a Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE mAnalytics Co-58 IN FILTERS 240 190 0 140 J, 90** a 40 -

-10 ,

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-i0 IOTBE mAnalytics B-16

1-131 IN CHARCOAL CARTRIDGE 1000 100 0m

  • i W0 11 6uw su1 im1 mSmmmm mmN81 m --

-- 10 "6

I--

1 0.1 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I #TBE mAnalytics March 2007 - New analyst did not count face B-17

1-131 IN WATER 1000 100

  • via

-o 10 5

I-0.1 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE "ERA Co-60 IN WATER 140 120 L100 A m 80 pm 60 rL 40 -

20 m w Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I #TBE BERA]

Cs-134 IN WATER 100 90 80 70 __

S60 t 50

  • p 040 CL 30 m 20 10U 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10

Cs-1 37 IN WATER 250 200 *=

1500 L) 100 50 a --. a 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I "TBE "ER7A February 2001 - Analyst error or equipment failure.

Sr-89 IN WATER 160 130 a,100 S70w = = l i*

40U,  ! I

  • 10 .

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE MER7A May 2004 - Counted without absorber.

Sr-90 IN WATER 40 a 30 a:5 U

.j 20 a 10 10 0

Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I OTBE EERA ]

B-19

Ba-133 IN WATER 120 100 80  !

60 I CL 40 20

  • 0 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10
  • TBE MERA Zn-65 IN WATER 380 330 d 280 f 230
  • j 180 C 130
  • 80 -

30 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I OTBE SERAI GROSS ALPHA IN WATER 90 80 70 60 0j 40 l p 30 20 10 p-0

  • B Io SER I Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 February 2000 - Analyst error or equipment failure.

B-20

GROSS BETA IN WATER 355 305 255 0205

,155 C'105 55 w Mom Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I "TBE "ER7A H-3 IN WATER 100000 10000 9 -- im

--

  • U 100 l1 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06 Jan-07 Jan-08 Jan-09 Jan-10 I *TBE IERA I B-21

APPENDIX C SYNOPSIS OF ANALYTICAL PROCEDURES C-1

SYNOPSIS OF ANALYTICAL PROCEDURES Appendix C is a synopsis of the analytical procedures performed during 2009 on samples collected for the Nebraska Public Power Nuclear Plant's Radiological Environmental Monitoring Program. All analyses have been mutually agreed upon by Nebraska Public Power District and Teledyne Brown Engineering and include those recommended by the USNRC Branch Technical Position, Rev. 1, November 1979.

ANALYSIS TITLE PAGE-Gross Beta A nalysis of A ir Particulate Sam ples .................................................................... C-3 A ir Particulates ........................................................................................................... C-3 D eterm ination of Gross Beta A ctivity in W ater Sam ples..................................................... C-4 Introduction ................................................................................................................ C-4 D etection Capabilities ................................................................................................ C-4 Analysis of Sam ples for Tritium (Liquid Scintillation) ......................................................... C-5 W ater ........................................................................................................................ C-5 Analysis of Sam ples for Iodine-131 ...................................................................................... C-6 M ilk or W ater ............................................................................................................. C-6 Gam m a Spectrom etry of Sam ples ......................................................................................... C-7 M ilk or W ater ......................... .. .................................................................................. C-7 Dried Solids other than Soils and Sedim ent .............................................................. C-7 Fish ........................................................................................................................... C-7 Soils and Sedim ents ................................................................................................... C-7 Charcoal Cartridges (A ir Iodine) .............................................................................. C-7 A irborne Particulates ........................................................................ ......................... C-8 Addendum to Gam m a Spectrom etry Procedure ................................................................... C-9 Environm ental D osim etry ................................................................................................ C-10 Low er Lim it of Detection Form ulas ................................................................................. C- 1I C-2

GROSS BETA ANALYSIS OF AIR PARTICULATE SAMPLES Air Particulates After a delay of five or more days, allowing for the radon-222 and radon-220 (thoron) daughter products to decay, the filters are counted in a gas-flow proportional counter.

Calculations of the results, the two sigma error and the lower limit of detection (LLD):

RESULT (pCi/m3) = ((S/T) - (B/t))/(2.22 V E)

TWO SIGMA ERROR (pCi/m3) = 2((S/T ) + (B/t 2 ))l/ 2 /(2.22 V E)

LLD (pCi/m3) = 4.66(B 1/2)/(2.22 V Et) where:

S Gross counts of sample including blank B Counts of blank E Counting efficiency T Number of minutes sample was counted t Number of minutes blank was counted V Sample aliquot size (cubic meters)

C-3

DETERMINATION OF GROSS BETA ACTIVITY IN WATER SAMPLES Introduction The procedures described in this section are used to measure the overall radioactivity of water samples without identifying the radioactive species present. No chemical separation techniques are involved.

One liter of the sample is evaporated on a hot plate. A smaller volume may be used if the sample has a significant salt content as measured gravimetrically. If requested by the customer, the sample is filtered through No. 54 filter paper before evaporation, removing particles greater than 30 microns in size.

After evaporating to a small volume in a beaker, the sample is rinsed into a 2-inch diameter stainless steel planchette, which is stamped with a concentric ring pattern to distribute residue evenly. Final evaporation to dryness takes place under heat lamps.

Residue mass is determined by weighing the planchette before and after mounting the sample. The planchette is counted for beta activity on an automatic proportional counter. Results are calculated using empirical self-absorption curves which allow for the change in effective counting efficiency caused by the residue mass.

Detection Capability Detection capability depends upon the sample volume actually represented on the planchette, the background and the efficiency of the counting instrument, and upon self-absorption of beta particles by the mounted sample. Because the radioactive species are not identified, no decay corrections are made and the reported activity refers to the counting time.

The minimum detectable level (MDL) for water samples is nominally 1.6 picoCuries per liter for gross beta at the 4.66 sigma level (1.0 pCi/L at the 2.83 sigma level), assuming that 1 liter of sample is used and that /2 gram of sample residue is mounted on the planchette. These figures are based upon a counting time of 50 minutes and upon representative values of counting efficiency and background of 0.2 and 1.2 cpm, respectively The MDL becomes significantly lower as the mount weight decreases because of reduced self-absorption. At a zero mount weight, the 4.66 sigma MDL for gross beta is 0.9 picoCuries per liter. These values reflect a beta counting efficiency of 0.38.

C-4

ANALYSIS OF SAMPLES FOR TRITIUM (Liquid Scintillation)

Water Ten milliliters of water are mixed with 10 ml of a liquid scintillation "cocktail" and then the mixture is counted in an automatic liquid scintillator.

Calculation of the results, the two sigma error and the lower limit detection (LLD) in pCi/L:

RESULT (N-B)/(2.22 V E)

TWO SIGMA ERROR 2((N + B)/At)/2/ (2.22 V E)

I/2 LLD 4.66(B/At) /(2.22 V E )

where: N = the gross cpm of the sample B = the background of the detector in cpm 2.22 = conversion factor changing dpm to pCi V = volume of the sample in ml E = efficiency of the detector At = counting time for the sample C-5

ANALYSIS OF SAMPLES FOR IODINE-131 Milk or Water Two or more liters of sample are first equilibrated with stable iodide carrier. A batch treatment with anion exchange resin is used to remove iodine from the sample. The iodine is then stripped from the resin with sodium hypochlorite solution, is reduced with hydroxylamine hydrochloride and is extracted into carbon tetrachloride as free iodine. It is then back-extracted as iodide into sodium bisulfite solution and is precipitated as palladium iodide. The precipitate is weighed for chemical yield and is mounted on a nylon planchette for low-level beta counting.

Calculations of results, two sigma error and the lower limit of detection (LLD) in pCi/L:

RESULT = (N/At-B)/(2.22 E V Y DF) 1/2 TWO SIGMA ERROR = 2((N/At+B)/At) /(2.22 E V Y DF) 1/2 LLD = 4.66(B/At) /(2.22 E V Y DF) where: N = total counts from sample (counts)

At = counting time for sample (min)

B = background rate of counter (cpm) 2.22 = dpm/pCi V = volume or weight of sample analyzed Y = chemical yield of the mount or sample counted DF - decay factor from the collection to the counting date E = efficiency of the counter for 1-131, corrected for self absorption effects by the formula E = Es(exp-0.006 1M)/(exp-0.006 1Ms)

Es = efficiency of the counter determined from an 1-131 standard mount MS = mass of Pd 12 on the standard mount, mg M = mass of PdI2 on the sample mount, mg C-6

GAMMA SPECTROMETRY OF SAMPLES Milk or Water A 1.0 liter Marinelli beaker is filled with a representative aliquot of the sample.

The sample is then counted for approximately 1000 minutes with a shielded high purity germanium (HPGe) detector coupled to a VAX-based data acquisition system, which performs pulse height analysis.

Dried Solids other than Soils and Sediments A large quantity of the sample is dried at a low temperature, less than 100'C. As much as possible (up to the total sample) is loaded into a tared 1-liter Marinelli and weighed. The sample is then counted for approximately 1000 minutes with a shielded HPGe detector coupled to a VAX-based data acquisition system, which performs pulse height analysis.

Fish As much as possible (up to the total sample) of the edible portion of the sample is loaded into a tared Marinelli and weighed. The sample is then counted for approximately 1000 minutes with a shielded HPGe detector coupled to a VAX-based data acquisition system, which performs pulse height analysis.

Soils and Sediments Soils and sediments are dried at a low temperature, less than 100°C. The soil or sediment is loaded fully into a tared, standard 300 cc container and weighed. The sample is then counted for approximately six hours with a shielded HPGe detector coupled to a VAX-based data acquisition system, which performs pulse height and analysis.

Charcoal Cartridges (Air Iodine)

Charcoal cartridges are counted up to five at a time, with one positioned on the face of an HPGe detector and up to four on the side of the HPGe detector. Each HPGe detector is calibrated for both positions. The detection limit for 1-131 of each charcoal cartridge can be determined (assuming no positive 1-131) uniquely from the volume of air, which passed through it. In the event l-131 is observed in the initial counting of a set, each charcoal cartridge is then counted separately, positioned on the face of the detector.

C-7

Air Particulates The thirteen airborne particulate filters for a quarterly composite for each field station are aligned one in front of another and then counted for at least six hours with a shielded HPGe detector coupled to a VAX-based data acquisition system which performs pulse height analysis.

A VAX software program defines peaks by certain changes in the slope of the spectrum. The program also compares the energy of each peak with a library of peaks for isotope identification and then performs the radioactivity calculation using the appropriate fractional gamma ray abundance, half-life, detector efficiency, and net counts in the peak region.

The calculation of results, two sigma error and the lower limit of detection (LLD) in pCi/volume or pCi/mass:

RESULT = (S-B)/(2.22 t E V F DF) 1/2 TWO SIGMA ERROR = 2(S+B) /(2.22 t E V F DF)

LLD = 4.66(B) /(2.22 t E V F DF) where: S = Area, in counts, of sample peak and background (region of spectrum of interest)

B = Background area, in counts, under sample peak, determined by a linear interpolation of the representative backgrounds on either side of the peak t = length of time in minutes the sample was counted 2.22 = dpm/pCi E = detector efficiency for energy of interest and geometry of sample V = sample aliquot size (liters, cubic meters, kilograms, or grams)

F = fractional gamma abundance (specific for each emitted gamma)

DF = decay factor from the mid-collection date to the counting date C-8

ADDENDUM TO GAMMA SPECTROMETRY PROCEDURE Ba-140 (half-life =~-1 2.8d) decays to LA-140 (half-life -40 hrs) and the daughter radionuclide, La-140 approaches - 90 % of the Ba-140 activity within- 6 days. The La-140 photon energy at 1596 keV is used to quantify the Ba-140 activity due to its high photon emission probability yield (96%) producing a higher count rate when present and therefore, a smaller associated counting error.

Zr-95 (half-life = -65d) decays to Nb-95. (half-life = -35d). The photon energy of Nb-95 (-765 keV) is used to quantify Zr-95 because of the high photon emission probability yield (~-100%) yielding a higher count rate and an associated lower counting error. The daughter radionuclide, Nb-95 approaches the Zr-95 activity after a time period of -65 days, an estimated time interval occurring between sample exposure, collection and shipping, and analysis.

C-9

ENVIRONMENTAL DOSIMETRY Environmental Dosimetry services are provided-by Global Dosimetry Solutions, Inc. (GDS). GDS uses a thermoluminescent dosimeter (TLD) manufactured by Panasonic, Inc. Panasonic identifies it as an UD-814A1 TLD. The TLD has four elements, numbered 1-4. Elements and their filtration are composed of:

ELEMENT MATERIAL FILTRATION 1 nLi 2nB4 0 7 -Cu Thin plastic 2 CaSO 4-Tm Lead 3 CaSO4-Tm Lead 4 CaSO 4-Tm Lead This material has a high light output, negligible thermally induced signal loss (fading) and negligible self-dosing. The energy response curve (as will as other features) satisfies NRC Regulatory Guide 4.13. Transit doses are accounted for by use of separate TLDs.

Prior to being sent to Cooper Nuclear Station, the GDS badges are exposed to Cs-137, to known a dose and read in the Panasonic UD-710 reader, with reference badges to establish an element response level for each badge. Badges are then re-annealed for assignment and distribution to Cooper Nuclear Station.

Following the field exposure the badges are returned to GDS for processing in a Panasonic UD-710 reader. Each element is heated and the measured light emission is recorded. The transit controls are read in the same manner. Total exposure for each badge is the average of Elements 2, 3, and 4.

Transit Controls are calculated using the following equation:

(E31 + E4 1 + E32 + E42) _ (E3t.mn + E4r,_)

TRANSDOSE= "4 2 C-10

LOWER LIMIT of DETECTION FORMULAS The LLD formulas in Appendix C are consistent with the LLD discussion in the ODAM. The term Sb in the ODAM equals 41B/t by Poisson statistics, where B = blank counts and t = blank counting intervals. The decay factor term e-2At in the ODAM is the same as the DF terms in Appendix C, but does not appear in certain analyses such as gross beta because decay does not apply. In the tritium analysis, decay is not considered because of the relatively long half-life.

Efficiencies and volumes are consistent between the two documents. Chemical yields appear in Appendix C where applicable but do not apply to other analyses such as tritium and gross beta.

C-1I

APPENDIX D DETECTION LIMITS AND REPORTING LEVELS D-1

NEBRASKA PUBLIC POWER - COOPER NUCLEAR STATION DETECTION LIMITS AND REPORTING LEVELS Isotope ODAM LLD NRC Rept. Level Water - pCi/liter Gross beta 4 N/A H-3 2000 20000(a) /30000(b)

Mn-54 15 1000 Fe-59 30 400 Co-58 15 1000 Co-60 15 300 Zn-65 30 300 Zr-95 30 400 Nb-95 15 400 1-131 1(C) 2 Cs-1 34 15 30 Cs-1 37 18 50 Ba-140 60 200 La-140 15 200 Air Filter - pCi/m 3 Gross Beta 0.01 N/A 1-131 0.07 0.9 Cs-1 34 0.05 10 Cs-137 0.06 20 Fish - pCi/kq-wet Mn-54 130 30000 Fe-59 260 10000 Co-58 130 30000 Co-60 130 10000 Zn-65 260 20000 Cs-1 34 130 1000 Cs-1 37 150 2000 Milk - pCi/liter 1-131 1 3 Cs-1 34 15 60 Cs-1 37 18 70 Ba-1 40 60 300 La-1 40 15 300 (a) For drinking water samples (b) For samples of water not used as a source of drinking water (c) LLD for drinking water D-2

NEBRASKA PUBLIC POWER - COOPER NUCLEAR STATION DETECTION LIMITS AND REPORTING LEVELS Isotope ODAM LLD NRC Rept. Level Vegetation - pCi/kq-wet 1-131 60 100 Cs-1 34 60 1000 Cs-1 37 80 2000 Sediment - pCi/kq-dry Cs-1 34 150 N/A Cs-137 180 N/A D-3

APPENDIX E REMP SAMPLING AND ANALYTICAL EXCEPTIONS E-1

EXCEPTIONS Appendix E contains the exceptions to the 2009 REMP Program. Where possible, causes of the deviation have been corrected to prevent recurrence.

Any deviations from the sampling schedule are documented on the data tables.

Data Tables are in Section VII.

E-2

Exceptions for Scheduled REMP Sampling and Analysis During 2009, NPPD Cooper Nuclear Station Air Station 9 experienced pump failure. Replaced pump. Week end 04/07/09 Air Station 3 rotometer was found reading low. Replaced pump. Week end 05/05/09 Air Station 2 rotometer was found reading low. Replaced pump. 06/30/09 Air Station 8 sample was unavailable due to the weather. 11/17/09 Air Station 8 sample was not taken. 12/29/09 Vegetation Station 28 no broadleaf vegetation was available. 2009 Vegetation Station 35 no broadleaf vegetation was available. 05/27/09, 09/29/09 and 10/27/09 Vegetation Station 96 no broadleaf vegetation was available. 05/27/09, 06/11/09, 09/29/09 and 10/27/09 Vegetation Station 101 no broadleaf vegetation was available. 05/27/09, 09/29/09 and 10/27/09 TLD station 87 was lost due to farmer "incident". First quarter 2009

APPENDIX F

SUMMARY

OF DOSES TO A MEMBER OF THE PUBLIC OFFSITE Fl

LIQUID EFFLUENT DOSE CALCULATIONS Doses to the maximum individual and 0 to 50 - mile population resulting from the release of radioactive material in liquid effluents from Cooper Nuclear Station were calculated using the LADTAP II computer program. The LADTAP II program implements the radiological dose models of Regulatory Guide 1.109 for determining the radiation exposure to man from three principal exposure pathways in the aquatic environment -- potable water, aquatic foods, and recreational water use. Doses to both the maximum individual and 0 to 50 mile population are calculated as a function of age group and pathway for significant body organs, and are presented in Tables 1 - 6.

Assumptions and data sources used for input to the LADTAP II code are described in a separate section of this appendix (see page F-52).

F-2

TABLE 1. Doses to Maximum Individual at the Site Boundary, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, January-June 2009 Cooper Nuclear Station Dose to Individual, mrem Period and Total Pathway Skin Bone Liver Body Thyroid Kidney Lung GI-LLI 1st Quarter Drinking 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-O0 0.00 E-00 0.00 E-00 0.00 E-O0 Water Shoreline 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-O0 Totals 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 2nd Quarter Eating Fish 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-O0 Drinking 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-O0 Water Shoreline 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 Totals 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 Totals for 1st & 2nd Quarters 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 0.00 E-00 Calculated doses are based on the following periods of exposures: Fishing: April - November; Drinking water and shoreline: January - December

TABLE 2. Doses to Maximum Individual at the Site Boundary, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, July-December 2009, Cooper Nuclear Station Dose to Individual, mrem Period and Total Pathway Skin Bone Liver Body Thyroid Kidney Lung GI-LLI 3rd Quarter Eating 1.80 E-03 4.34 E-04 4.82 E-04 2.87 E-04 3.16 E-04 2.87 E-04 6.39 E-04 Fish Drinking 4.43 E-03 2.36 E-02 2.38 E-02 2.36 E-02 2.36 E-02 2.36 E-02 2.41 E-02 Water Shoreline 2.34 E-04 1.99 E-04 1.99 E-04 1.99 E-04 1.99 E-04 1.99 E-04 1.99 E-04 1.99 E-04 Totals 2.34 E-04 6.43 E-03 2.43 E-02 2.45 E-02 2.40 E-02 2.41 E-02 2.40 E-02 2.49+E-02 4th Quarter Eating Fish 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Drinking 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Water Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals for 3rd & 4th Quarters 2.34 E-04 6.43 E-03 2.43 E-02 2.45 E-02 2.40 E-02 2.41 E-02 2.40 E-02 2.49 E-02 Calculated doses are based on the following periods of exposures: Fishing: April - November; Drinking water and shoreline: January - December

TABLE 3. Summary of-Doses to Maximum Individual at the Site Boundary, Resulting from Exposure Discharged in Liquid Effluents, January-December to Radioactivity 2009, Cooper Nuclear Station Dose to Individual, mrem Period and Pathway Total Skin Bone Liver Body Thyroid Kidney Lung GI-LLI Ist Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 2nd Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 3rd Quarter 2.34 E-04 6.43 E-03 2.43 E-02 2.45 E-02 2.40 E-02 2.41 E-02 2.40 E-02 2.49 E-02 4th Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals for 2009 2.34 E-04 6.43 E-03 2.43 E-02 2.45 E-02 2.40 E-02 2.41 E-02 2.40 E-02 2.49 E-02

TABLE 4. Doses to Population Within a 50-Mile Radius, Resulting From E2xposure to Radioactivity Discharged in Liquid Effluents, January-June 2009, Cooper Nuclear Station Dose to Population, manrem Period and Total Pathway Skin Bone Liver Body Thyroid Kidney Lung GI-LLI 1st Quarter Drinking 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Water Shoreline 0,.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 2nd Quarter Eating Fish 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Drinking 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Water Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Swimming 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Boating 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals for 1st & 2nd Quarters 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Calculated dos es are based on the following periods of exposures: Fishing and Boating: April - November; Drinking water and shoreline: January - December; Swimming: June - September Exposure from drinking water is calculated for the city of St. Joseph, Missouri, nearest public water intake from the Missouri River, 84 miles downstream

TABLE 5. Doses to Population Within a 50-Mile Radius, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, July-December 2009, Cooper Nuclear Station Dose to Population, manrem Period and Total Pathway Skin Bone Liver Body Thyroid Kidney Lung GI-LLI 3rd Quarter Eating 1.32 E-04 4.25 E-05 4.30 E-05 2.97 E-05 3.23 E-05 2.97 E-05 1.18 E-04 Fish Drinking 3.070E-03 2.19 E-02 2.20 E-02 2.18 E-02 2.18 E-02 2.18 E-02 2.28 E-02 Water Shoreline 3.31 E-04 0.00 E+00 0.00 E+00 2.82 E-04 2.82 E-04 0.00 E+00 0.00 E+00 0.00 E+00 Swimming 0.00 E+00 0.00 E+00 0.00 E+00 1.71 E-06 1.71 E-06 0.00 E+00 0.00 E+00 0.00 E+00 Boating 0.00 E+00 0.00 E+00 0.00 E+00 6.26 E-06 6.26 E-06 0.00 E+00 0.00 E+00 0.00 E+00 Totals 3.31 E-04 3.20 E-03 2.19 E-02 2.23 E-02 2.21 E-02 2.18 E-02 2.18 E-02 2.29 E-02 4th Quarter Eating Fish 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Drinking 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Water Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals for 3rd & 4th Quarters 3.31 E-04 3.20 E-03 2.19 E-02 2.23 E-02 2.21 E-02 2.18 E-02 2.18 E-02 2.29 E-02 Calculated doses are based on the following periods of exposures: Fishing and Boating: April - November; Drinking water and shoreline: January - December; Swimming: June - September Exposure from drinking water is calculated for the city of St. Joseph, Missouri, nearest public water intake from the Missouri River, 84 miles downstream

TABLE 6. Summary of Doses to Population Within a 50-Mile Radius, Resulting from Exposure to Radioactivity Discharged in Liquid Effluents, January-December 2009 Cooper Nuclear Station Dose to Population, manrem Period and Total Pathway Skin Bone Liver Body Thyroid Kidney Lung GI-LLI ist 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Quarter 2nd Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 3rd Quarter 3.31 E-04 3.20 E-03 2.19 E-02 2.23 E-02 2.21 E-02 2.18 E-02 2.18 E-02 2.29 E-02 4th Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals for 2009 3.31 E-04 3.20 E-03 2.19 E-02 2.23 E-02 2.21 E-02 2.18 E-02 2.18 E-02 2.29 E-02

GASEOUS EFFLUENT DOSE CALCULATIONS Doses to the maximum individual and 0 to 50 mile population resulting from the release of radioactive material in gaseous effluents from the Cooper Nuclear Station were calculated using the GASPAR computer code. Four sites were selected for individual dose calculations: the site boundary, the nearest residence, the nearest garden and the nearest cow. GASPAR implements the radiological dose models of Regulatory Guide 1.109 for determining the radiation exposure to man from four principal atmospheric exposure pathways: plume, ground, inhalation, and ingestion. Doses to the maximum individual and the population are calculated as a function of age group and pathway for significant body organs.

Tables 1 through 7 present maximum individual doses. Population doses are given in Tables 8 through 14.

Assumptions and data used for input to the GASPAR code are described in a separate section of this appendix (see page F-52).

F-9

TABLE 1. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-MARCH 2009 SPECIAL LOCATION NO. 1 A Site Boundary AT .69 MILES NNW ANNUAL BETA AIR DOSE = 1.12E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 8.11E-04 MILLRADS PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-- + ------------------- +---------------------------------------------- ---------------------------

+

PLUME  : 5.28E-04  : 5.28E-04  : 5.28E-04  : 5.28E-04  : 5.28E-04  : 5.28E-04  : 5.39E-04 : 1.32E-03

- + -------------------- +------------------------------ ------------- +---------------+---------------

GROUND  : 7.76E-04 : 7.76E-04 : 7.76E-04 : 7.76E-04 : 7.76E-04 : 7.76E-04 : 7.76E-04 : 9.13E-04

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :  :  :

ADULT 2.62E-05 1.39E-04 2.32E-04 1.97E-05 2.46E-05 4.69E-03 1.74E-17 0.OOE+00

+-------------------------------------------------

+ -+-------------- +

TEEN  : 4.05E-05 : 1.54E-04  : 3.84E-04  : 3.OOE-05  : 3.74E-05  : 6.33E-03  : 1.96E-17 : 0.OOE+00

- + -------------------- +---------------------------------------------------------------------------

CHILD  : 8.33E-05 : 1.07E-04 : 9.37E-04 : 4.94E-05 : 6.03E-05 : 1.21E-02 : 2.34E-17 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  : .  :  :  :

ADULT 3.42E-06 2.72E-05 2.42E-06 1.81E-06 6.63E-07 1.27E-04 0.OOE+00 0.OOE+00

+---*-----------------+------------------------------ ----------------------------- +---------------

TEEN  : 2.71E-06  : 1.47E-05  : 2.04E-06 : 1.42E-06  : 5.42E-07  : 9.17E-05  : 0.OOE+00  : 0.OOE+00

+---*-----------------+---------------+--------------- ----------------------------- ---------------

CHILD  : 4.20E-06 : 7.43E-06 : 3.86E-06 : 1.73E-06 : 6.88E-07 : 1.38E-04 : 0.OOE+00 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  :

ADULT  : 7.10E-06 1.03E-05 1.78E-05 1.10E-05 1.83E-05 3.50E-03 2.61E-23 0.OOE+00

+---*-----------------+---------------------------------------------------------------------------

TEEN  : 1.19E-05  : 1.29E-05  : 3.27E-05 : 1.95E-05  : 3.27E-05  : 5.53E-03  : 5.78E-23 : 0.OOE+00

+--*-------------------------------+------------------------------ --------------- +---------------

CHILD  : 2.25E-05 : 9.33E-06 : 8.01E-05 : 3.39E-05 : 5.43E-05 : 1.09E-02 : 9.20E-23 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 4.21E-05 : 8.74E-06 : 1.58E-04 : 8.26E-05 : 9.45E-05 : 2.65E-02 : 2.51E-22 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :

ADULT  : 8.05E-06 7.60E-06 3.07E-05 1.29E-05 2.20E-05 4.20E-03 3.13E-24 0.OOE+00 S+ + - - ------- --------------- +---------------+

+-------------------------------+----------------

TEEN  : 1.35E-05  : 1.01E-05  : 5.64E-05 : 2.28E-05  : 3.92E-05 : 6.64E-03  : 6.94E-24  : 0.OOE+00

++--------------------------------------------------------------------------------+---------------

CHILD  : 2.57E-05  : 7.95E-06  : 1.39E-04  : 3.98E-05  : 6.52E-05 : 1.31E-02  : 1.1OE-23 : 0.OOE+00

+---*+-----------------------------------------------------------------------------+-------------+

INFANT  : 4.85E-05 : 7.86E-06 : 2.71E-04 : 9.73E-05 : 1.13E-04 : 3.19E-02 : 3.01E-23 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  : .  :  :

ADULT 5.44E-07 3.81E-06 1.46E-06 8.31E-07 1.29E-06 2.40E-04 4.78E-05 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 7.11E-07 : 7.62E-06 : 2.07E-06 : 1.14E-06 : 1.76E-06 : 2.95E-04 : 7.17E-05 : O.OOE+00

+-------------------+---------------+---------------+---------------+---------------+---------------+----- r----------+

CHILD  : 7.67E-07 : 4.19E-05 : 2.84E-06 : 1.10E-06 : 1.65E-06 : 3.30E-04 : 5.91E-05 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 5.18E-07 : 3.63E-05 : 2.01E-06 : 9.90E-07 : 1.09E-06 : 3.01E-04 : 4.13E-05 : 0.OOE+00

-+--*-----------------+----------------------------------------------------------+---------------+

TABLE 1. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-MARCH 2009 (Continued)

SPECIAL LOCATION NO. 2 A Site Boundary AT .67 MILES N ANNUAL BETA AIR DOSE = 1.49E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.00E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN PLUME  : 6.49E-04  : 6.49E-04  : 6.49E-04  : 6.49E-04  : 6.49E-04  : 6.49E-04  : 6.63E-04  : 1.67E-03

......... ----- - *+---------------------------------------------- -----------------------------------

GROUND  : 9.44E-04 : 9.44E-04 : 9.44E-04 : 9.44E-04 : 9.44E-04 : 9.44E-04 : 9.44E-04 : 1.llE-03

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :

ADULT 3.18E-05 1.69E-04 2.82E-04 2.38E-05 2.96E-05 5.65E-03 2.11E-17 0.OOE+00

......... -- *+---------------------------------------------- +--------------------------------------

TEEN  : 4.91E-05 : 1.87E-04  : 4.67E-04  : 3.62E-05  : 4.51E-05  : 7.63E-03 : 2.38E-17  : 0.OOE+00

......- +-*--------------------------------+--------------- +------- ------------------------------- +

CHILD  : 1.01E-04 : 1.31E-04 : 1.14E-03 : 5.97E-05 : 7.27E-05 : 1.46E-02 : 2.84E-17 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  : .  :

ADULT 4.16E-06 3.31E-05 2.95E-06 2.20E-06 7.99E-07 1.53E-04 0.OOE+00 0.OOE+00

......... ----- - *+-------------------------------+--------------- ----------------------------------

TEEN  : 3.29E-06 : 1.78E-05  : 2.48E-06  : 1.72E-06  : 6.53E-07  : 1.11E-04  : 0.OOE+00  : 0.OOE+00

++. +---------------------------------------+

CHILD  : 5.11E-06 : 9.05E-06 : 4.69E-06 : 2.10E-06 : 8.29E-07 : 1.67E-04 : 0.OOE+00 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  : . .  :

ADULT  : 8.57E-06 1.25E-05 2.16E-05 1.33E-05 2.21E-05 4.22E-03 3.17E-23 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.44E-05 : 1.57E-05 : 3.96E-05 : 2.35E-05 : 3.94E-05 : 6.67E-03 : 7.03E-23 : O.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 2.72E-05 : 1.13E-05 : 9.72E-05 : 4.09E-05 : 6.55E-05 : 1.32E-02 : 1.12E-22 ; 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 5.08E-05 : 1.06E-05 : 1.92E-04 : 9.96E-05 : 1.14E-04 : 3.20E-02 : 3.05E-22 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : .

ADULT  : 9.71E-06 9.21E-06 3.73E-05 1.55E-05 2.65E-05 5.06E-03 3.80E-24 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.63E-05 : 1.23E-05 : 6.84E-05 : 2.75E-05 : 4.73E-05 : 8.00E-03 : 8.44E-24 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 3.10E-05 : 9.64E-06 : 1.68E-04 : 4.80E-05 : 7.86E-05 : 1.58E-02 : 1.34E-23 : O.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 5.86E-05 : 9.53E-06 : 3.29E-04 : 1.17E-04 : 1.37E-04 : 3.84E-02 : 3.66E-23 : O.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  :  :

ADULT 7.53E-07 5.27E-06 2.01E-06 1.15E-06 1.78E-06 3.32E-04 6.61E-05 0.OOE+00

+---*-----------------+---------------+--------------- ------------------------------------------- +

TEEN  : 9.85E-07 : 1.05E-05  : 2.86E-06  : 1.57E-06  : 2.44E-06 : 4.09E-04  : 9.91E-05  : 0.OOE+00

+---*-----------------+---------------+--------------- ------------------------------------------- +

CHILD  : 1.06E-06  : 5.79E-05 : 3.93E-06  : 1.53E-06  : 2.29E-06 : 4.57E-04  : 8.17E-05  : 0.OOE+00


S+ - ------------------ +---------------+--------------- +------------------------------------ +

INFANT : 7.17E-07 : 5.02E-05  : 2.78E-06  : 1.37E-06  : 1.51E-06  : 4.18E-04  : 5.71E-05  : 0.OOE+00

-+--*-----------------+---------------+--------------- ------------------------------------------- +

TABLE 1. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-MARCH 2009 (Continued)

SPECIAL LOCATION NO. 3 A Nearest Resident AT .90 MILES NW ANNUAL BETA AIR DOSE = 1.OOE-03 MILLRADS ANNUAL GAMMA AIR DOSE = l.19E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

.+-. -.. -+-----------------------------------------------+--------------- --------------------------

PLUME  : 7.90E-04 : 7.90E-04 : 7.90E-04 : 7.90E-04 : 7.90E-04 : 7.90E-04 : 8.OOE-04 : 1.65E-03 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 3.89E-04 : 3.89E-04 : 3.89E-04 : 3.89E-04 . 3.89E-04 : 3.89E-04 : 3.89E-04 : 4.58E-04 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :

ADULT 1.47E-05 7.03E-05 1.18E-04 1.26E-05 1.70E-05 3.25E-03 9.06E-18 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+-------------- ---------------- +

TEEN  : 2.25E-05 : 7.80E-05 : 1.95E-04 : 1.92E-05 : 2.59E-05 : 4.38E-03 : 1.02E-17 : 0.OOE+00


+---------------------------------------------------------------------------------------------

CHILD  : 4.58E-05 : 5.44E-05 : 4.77E-04 : 3.18E-05  : 4.17E-05  : 8.39E-03 : 1.22E-17  : 0.OOE+00

+------------------+---------------+---------------+---------------+---------------+--------- ------

NEAT - .  :

ADULT 1.76E-06 1.36E-05 1.27E-06 9.82E-07 4.59E-07 8.77E-05 0.OOE+00 0.OOE+00

-+------------------------------------+--------------- +-------------------------------------------

TEEN  : 1.39E-06 : 7.36E-06  : 1.07E-06 : 7.72E-07  : 3.75E-07  : 6.35E-05 : 0.OOE+00 0.OOE+00

-+- - +-----------------+---------------+---------------+----------------------------

CHILD  : 2.15E-06  : 3.73E-06  : 2.01E-06 : 9.48E-07  : 4.76E-07  : 9.59E-05 : 0.OOE+00 0.OOE+00

+-+- ---------------- + +----------------


+--------------------------------------------

COW MILK :  :  :

ADULT  : 4.73E-06 5.72E-06 1.04E-05 7.55E-06 1.27E-05 2.42E-03 1.36E-23 0.OOE+00

+ -+-----------------------------+ 4 +--------------- +-------------------------------------------

TEEN  : 7.92E-06 : 7.19E-06  : 1.90E-05 : 1.34E-05  : 2.26E-05  : 3.83E-03  : 3.02E-23 : 0.OOE+00

-- +-----------------------------------+--------------- +---------------------------- ---------------

CHILD  : 1.49E-05 : 5.24E-06  : 4.64E-05 : 2.33E-05  : 3.76E-05  : 7.56E-03 : 4.80E-23  : 0.OOE+00

++--------------- - - ---------------- +---------------+--------------- ----------------------------

+ +

INFANT  : 2.79E-05 : 4.93E-06 : 9.25E-05 : 5.68E-05 : 6.54E-05 : 1.84E-02 : 1.31E-22 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : -  :  :  :

ADULT  : 5.43E-06 4.46E-06 1.71E-05 8.89E-06 1.52E-05 2.90E-03 1.63E-24 0.OOE+00

-+------------------------------------+--------------- +-------------------------------------------

TEEN  : 9.11E-06 : 5.95E-06 : 3.14E-05 : 1.58E-05 : 2.71E-05 : 4.59E-03 : 3.62E-24 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.72E-05 : 4.67E-06 : 7.71E-05 : 2.75E-05 : 4.51E-05 : 9.07E-03 : 5.76E-24 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 3.25E-05 : 4.60E-06 : 1.52E-04 : 6.73E-05 : 7.84E-05 : 2.20E-02 : 1.57E-23 : 0.OOE+00

-+-------+-------------+---------------+---------------+---------------+-----------+---------------+---------------+

INHAL . - .  :  :

ADULT 2.22E-07 1.39E-06 5.58E-07 3.47E-07 5.38E-07 9.98E-05 1.73E-05 0.OOE+00

-+------------------------------------+--------------- +---------------------------- ---------------

TEEN  : 2.91E-07  : 2.79E-06 : 7.92E-07  : 4.75E-07  : 7.39E-07  : 1.23E-04  : 2.60E-05 : 0.OOE+00

-+------------------------------------+--------------- +-------------------------------------------

CHILD  : 3.13E-07 : 1.53E-05  : 1.09E-06  : 4.61E-07  : 6.93E-07  : 1.37E-04  : 2.14E-05 : 0.OOE+00

++------ +-------------------------

INFANT  : 2.13E-07  : 1.33E-05  : 7.74E-07  : 4.15E-07  : 4.56E-07  : 1.25E-04 : 1.50E-05 : 0.OOE+00

+---------------------------- +--------------------------------------------

TABLE 1. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-MARCH 2009 (Continued)

SPECIAL LOCATION NO. 4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 4.83E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 7.13E-04 MILLRADS PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+-+------------------+---------------+------------------------------ ---------------------------- +

PLUME  : 4.78E-04  : 4.78E-04  : 4.78E-04  : 4.78E-04  : 4.78E-04  : 4.78E-04  : 4.83E-04  : 9.42E-04

+-+-------------------+---------------+--------------- ------------------------------------------- +

GROUND  : 1.55E-05  : 1.55E-05  : 1.55E-05 : 1.55E-05  : 1.55E-05  : 1.55E-05 : 1.55E-05  : 1.82E-05

+---*+--------------------------------+--------------- ------------------------------------------- +

VEGET  :  :

ADULT 6.99E-07 2.85E-06 4.83E-06 7.02E-07 1.02E-06 1.95E-04 1.59E-19 0.OOE+00

+---*+--------------------------------+----------------------------------------------------------+

TEEN  : 1.06E-06 : 3.16E-06  : 7.98E-06 : 1.07E-06  : 1.55E-06  : 2.63E-04  : 1.80E-19  : 0.OOE+00

+---*+--------------------------------+--------------- --------------------------- +---------------+

CHILD  : 2.11E-06 : 2.21E-06  : 1.95E-05 : 1.78E-06  : 2.50E-06 : 5.03E-04  : 2.15E-19  : O.OOE+00

-+-+------------------+---------------+--------------- --------------------------- +---------------+

HEAT .  :  : .  :

ADULT 7.30E-08 5.44E-07 5.41E-08 4.44E-08 2.75E-08 5.26E-06 0.OOE+00 0.OOE+00

+---*-----------------+---------------+--------------- --------------------------- +---------------+

TEEN  : 5.76E-08  : 2.94E-07  : 4.55E-08 : 3.51E-08  : 2.25E-08 : 3.81E-06  : 0.OOE+00  : 0.OOE+00

+-+-------------------+---------------+--------------- --------------------------- +---------------+

CHILD  : 8.89E-08  : 1.49E-07  : 8.58E-08 : 4.36E-08  : 2.85E-08 : 5.75E-06  : 0.OOE+00  : 0.OOE+00

-+--*+--------------------------------+---------------+--------------- +---------- --------------- +

COW MILK  : .  :  :

ADULT  : 2.73E-07 2.67E-07 5.16E-07 4.49E-07 7.60E-07 1.45E-04 2.39E-25 0.OOE+00

+-+----+------------------------------+--------------- --------------------------- +---------------+

TEEN  : 4.57E-07  : 3.39E-07  : 9.42E-07  : 7.98E-07  : 1.36E-06 : 2.29E-04  : 5.31E-25 : 0.OOE+00

+ -+-----------------+---------------+--------------- --------------------------------------------

CHILD  : 8.54E-07  : 2.50E-07  : 2.30E-06 : 1.39E-06  : 2.25E-06 : 4.53E-04  : 8.45E-25  : 0.OOE+00

+-+-------------------+---------------+--------------- --------------------------- +---------------+

INFANT : 1.60E-06  : 2.37E-07  : 4.64E-06 : 3.39E-06  : 3.92E-06 : 1.10E-03  : 2.30E-24 . 0.OOE+00

-+-+------------------+---------------+--------------- --------------------------- +---------------+

GOATMILK  :  : .  :  :

ADULT  : 3.19E-07 2.25E-07 8.05E-07 5.33E-07 9.12E-07 1.74E-04 2.87E-26 0.OOE+00

+-+-------------------+---------------+--------------- --------------------------- +---------------+

TEEN  : 5.33E-07 : 2.99E-07  : 1.47E-06 : 9.46E-07 : 1.63E-06  : 2.75E-04  : 6.37E-26  : 0.OOE+00

+---*+--------------------------------+--------------- --------------------------- +---------------+

CHILD  : 9.97E-07  : 2.35E-07  : 3.61E-06 : 1.65E-06  : 2.70E-06 : 5.44E-04  : 1.01E-25  : 0.OOE+00

+-+-------------------+---------------+--------------- --------------------------- +---------------+

INFANT : 1.89E-06 : 2.32E-07 : 7.17E-06 : 4.03E-06 : 4.70E-06 : 1.32E-03 : 2.76E-25 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  : .  :

ADULT 3.28E-08 1.11E-07 6.38E-08 5.46E-08 8.51E-08 1.54E-05 1.40E-06 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 4.29E-08 : 1.61E-07 : 9.04E-08 : 7.49E-08 : 1.17E-07 : 1.90E-05 : 2.09E-06 : 0.OOE+00 S+-------+-------------+---------------+---------------+---------------+-----------+---------------+---------------+

CHILD  : 4.60E-08 : 5.86E-07 : 1.24E-07 : 7.30E-08 : 1.10E-07 : 2.11E-05 : 1.72E-06 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 3.21E-08 : 5.OOE-07 : 9.06E-08 : 6.66E-08 : 7.21E-08 : 1.93E-05 : 1.18E-06 : 0.OOE+00

-+ --------------------------- +---------------+

+------------------+---------------+---------------

TABLE 1. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-MARCH 2009 (Continued)

SPECIAL LOCATION NO. 5 A Nearest Garden AT 1.30 MILES SW ANNUAL BETA AIR DOSE = 5.32E-04 MILLRADS ANNUAL GA14MA AIR DOSE = 7.43E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 4.98E-04 : 4.98E-04 : 4.98E-04 -- 4.98E-04 : 4.98E-04 : 4.98E-04 : 5.03E-04 : 9.94E-04 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 5.78E-05 : 5.78E-05 : 5.78E-05 : 5.78E-05 : 5.78E-05 : 5.78E-05 : 5.78E-05 : 6.80E-05 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :  :  :  :

ADULT 2.52E-06 1.06E-05 1.79E-05 2.46E-06 3.53E-06 6.75E-04 9.50E-19 0.OOE+00 S+-------+---------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.82E-06 : 1.18E-05 : 2.96E-05 : 3.74E-06 : 5.38E-06 : 9.10E-04 : 1.07E-18 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 7.65E-06 : 8.21E-06 : 7.23E-05 : 6.23E-06 : 8.67E-06 : 1.74E-03 : 1.28E-18 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

NEAT ADULT 2.70E-07 2.03E-06 1.99E-07 1.62E-07 9.54E-08 1.82E-05 0.OOE+00 0.OOE+00

- +++--------------------------------------------------------------+------------------------------

TEEN  : 2.13E-07 : 1.10E-06 : 1.67E-07 : 1.27E-07 : 7.79E-08 : 1.32E-05 0.OOE+00 0.OOE+00

-+-------------------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 3.29E-07 : 5.56E-07 : 3.16E-07 : 1.58E-07 : 9.90E-08 : 1.99E-05 : 0.OOE+00 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  : .

ADULT  : 9.53E-07 9.65E-07 1.84E-06 1.56E-06 2.63E-06 5.03E-04 1.43E-24 0.OOE+00

- - S+-- ------------------------------------------------------------- +------------------------------

TEEN  : 1.59E-06  : 1.22E-06 : 3.37E-06 : 2.77E-06  : 4.70E-06  : 7.96E-04  : 3.16E-24  : 0.OOE+00

- - S+-- ------------------------------------------------------------- +------------------------------

CHILD  : 2.98E-06  : 9.OOE-07 : 8.24E-06 : 4.82E-06 : 7.81E-06 : 1.57E-03 : 5.04E-24 : 0.OOE+00

- -S+-- ------------------------------------------------------------- +------------------------------

INFANT  : 5.59E-06 : 8.52E-07 : 1.66E-05 : 1.18E-05 : 1.36E-05 : 3.82E-03 : 1.37E-23 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : .  :  :  :  :

ADULT  : 1.11E-06 8.01E-07 2.91E-06 1.85E-06 3.16E-06 6.04E-04 1.71E-25 0.OOE+00

- ++------------------+--------------------------------------------+------------------------------

TEEN  : 1.85E-06  : 1.07E-06 : 5.32E-06  : 3.28E-06  : 5.64E-06  : 9.55E-04  : 3.80E-25  : 0.OOE+00

- ++------------------+--------------------------------------------+------------------------------

CHILD  : 3.47E-06  : 8.38E-07 : 1.31E-05 : 5.71E-06 : 9.37E-06 : 1.89E-03 : 6.04E-25 : 0.0OE+00

- - S--- -------------------------------- +---------------+----------------+----------- ---------------

INFANT  : 6.57E-06 : 8.26E-07 : 2.59E-05 : 1.40E-05 : 1.63E-05 : 4.58E-03 : 1.65E-24 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  : .  : .

ADULT 5.89E-08 2.88E-07 1.34E-07 9.44E-08 1.47E-07 2.69E-05 3.67E-06 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 7.70E-08 : 4.85E-07 : 1.89E-07 : 1.29E-07 : 2.01E-07 : 3.31E-05 :'5.48E-06 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 8.28E-08 : 2.23E-06 : 2.60E-07 : 1.26E-07 : 1.89E-07 : 3.70E-05 : 4.51E-06 : 0.OOE+00 IN T----0----------------- --------------

0---------------1. -----

0-0----------------1---------------0 INFANT :5.69E-08 :1.92E-06 :1.87E-07 :1.14E-07 :1.24E-07 :3.38E-05 :3.12E-06 :0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2009 SPECIAL LOCATION NO. 1 A Site Boundary AT .80 MILES S ANNUAL BETA AIR DOSE = 6.34E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 5.66E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+---+--------------------------------+---------------+--------------- +----------- ---------------

PLUME  : 3.75E-05  : 3.75E-05  : 3.75E-05 : 3.75E-05  : 3.75E-05 : 3.75E-05  : 3.81E-05  : 9.29E-05

-+--------------------------------------------------- ---------------------------------------------

GROUND  : 1.76E-03 : 1.76E-03 : 1.76E-03 : 1.76E-03 : 1.76E-03 : 1.76E-03 : 1.76E-03 : 2.07E-03 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET '  :

ADULT  : 3.06E-05 2.36E-04 6.59E-05 1.62E-05 7.18E-06 1.37E-03 2.47E-09 0.OOE+00

+ + +---------------------------

TEEN  : 4.78E-05 : 2.53E-04 : 1.09E-04 : 2.47E-05 : 1.09E-05 : 1.85E-03 : 4.63E-09 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 9.66E-05 : 1.67E-04 : 2.66E-04 : 3.90E-05 : 1.76E-05 : 3.54E-03 : 7.04E-09 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

HEAT  :  :

ADULT 7.20E-06 6.07E-05 6.91E-07 3.34E-06 1.94E-07 3.69E-05 2.01E-10 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 5.70E-06 : 3.27E-05 : 5.82E-07 : 2.60E-06 : 1.58E-07 : 2.67E-05 : 1.91E-10 : 0.OOE+00 S--*------------------------------------------------- +--------------------------------------------

CHILD  : 8.86E-06 : 1.65E-05 : 1.10E-06 : 3.10E-06 : 2.01E-07 : 4.04E-05 : 2.24E-10 : 0.OOE+00


*--------------------------------------------------------------+------------------------------

COW MILK : . -  :

ADULT 3.44E-06 1.45E-05 5.14E-06 3.86E-06 5.38E-06 1.02E-03 1.70E-09 0.OOE+00 S+--------+----------------------+---------------+---------------+---------------+---------------+---------------+

TEEN 5.83E-06 : 1.73E-05 : 9.41E-06 : 6.79E-06 : 9.60E-06 : 1.62E-03 : 3.52E-09 : 0.OOE+00


*--------------------------------------------------------------------------------------------+

CHILD  : 1.14E-05  : 1.17E-05 : 2.31E-05 : 1.16E-05 : 1.60E-05 : 3.20E-03 : 5.41E-09 : 0.00E+00 S---*--------------------------------------------------------------------------------------------+

INFANT  : 2.01E-05 : 1.04E-05 : 4.57E-05 : 2.76E-05 : 2.78E-05 : 7.77E-03 : 9.79E-09 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : . .  :  :  :

ADULT  : 2.54E-06 3.59E-06 8.83E-06 3.89E-06 6.47E-06 1.23E-03 5.11E-09 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 4.25E-06 : 4.58E-06 : 1.62E-05 : 6.91E-06 : 1.15E-05 : 1.94E-03 : 1.06E-08 : 0.OOE+00 S-*--- ----------------------------------------------- +---------------------------+---------------+

CHILD  : 8.08E-06 : 3.39E-06 : 3.99E-05 : 1.20E-05 : 1.92E-05 : 3.84E-03 : 1.62E-08 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 1.51E-05 : 3.24E-06 : 7.79E-05 : 2.92E-05 : 3.33E-05 : 9.32E-03 : 2.94E-08 : 0.OOE+00 S+-------+-------------+---------------+---------------+---------------+---------------+-----------+---------------+

INHAL .  :  :  :  : -

ADULT 3.44E-07 5.08E-06 4.08E-07 4.11E-07 4.30E-07 7.43E-05 8.74E-05 0.OOE+00


+---------------------------


+-------------------------------------------+

TEEN  : 4.56E-07  : 9.53E-06  : 5.79E-07 : 5.55E-07 : 5.91E-07  : 9.21E-05  : 1.29E-04  : 0.OOE+00

- -*--- ----------------------------------- +---------------- +---------------------------------------+

CHILD  : 5.09E-07  : 5.13E-05  : 7.93E-07 : 5.21E-07 : 5.55E-07  : 1.04E-04  : 1.05E-04  : 0.OOE+00 4+ - +----------------+--------------- -+-------- +---------------- ---------------------------- +

INFANT  : 3.02E-07  : 4.45E-05 : 5.68E-07 : 4.25E-07  : 3.65E-07  : 9.53E-05  : 6.95E-05  : 0.OOE+00

- +--------------------- ------------------------------ +-------------------------------------------+

TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 2 A Site Boundary AT .67 MILES N ANNUAL BETA AIR DOSE = 7.82E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 6.97E-05 MILLEADS PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+---------------+---------------+--------------- -------------------------- +---------------

PLUME  : 4.62E-05 : 4.62E-05 : 4.62E-05 : 4.62E-05 : 4.62E-05 : 4.62E-05 : 4.70E-05 : 1.14E-04


+ --------------- +---------------------------------------------------------+---------------

GROUND  : 2.21E-03 : 2.21E-03 : 2.21E-03 : 2.21E-03 : 2.21E-03 : 2.21E-03 : 2.21E-03 : 2.59E-03


+ --------------- +------------------------------------------------------------+-------------

VEGET  :  : .  :  :

ADULT 3.84E-05 2.96E-04 8.29E-05 2.03E-05 9.09E-06 1.73E-03 3.84E-09 0.OOE+00


+ --------------- +---------------+---------------+-- ----------------------- +---------------

TEEN  : 6.OOE-05 : 3.18E-04 : 1.37E-04 : 3.11E-05 : 1.38E-05 : 2.34E-03 : 7.20E-09 : O.OOE+00


+ --------------- +---------------------------------------------------------+---------------

CHILD  : 1.21E-04 : 2.10E-04 : 3.35E-04 : 4.91E-05 : 2.23E-05 : 4.48E-03 : 1.09E-08 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

NEAT  :  :  : .  :

ADULT 9.04E-06 7.63E-05 8.70E-07 4.20E-06 2.45E-07 4.67E-05 3.13E-10 0.OOE+00


+ -------------------------------------------------------------- ---------- -+---------------

TEEN  : 7.16E-06 : 4.11E-05 : 7.33E-07 : 3.26E-06 : 2.OOE-07  : 3.38E-05  : 2.97E-10  : 0.OOE+00


+ --------------- +---------------------------------------------------------+---------------

CHILD  : 1.11E-05 : 2.07E-05 : 1.38E-06 : 3.89E-06 : 2.55E-07 : 5.11E-05 : 3.48E-10 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  :

, ADULT  : 4.34E-06 1.83E-05 6.49E-06 4.88E-06 6.81E-06 1.29E-03 2.65E-09 0.OOE+00

-- - - -------------------- +---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 7.36E-06 : 2.18E-05  : 1.19E-05 : 8.59E-06  : 1.22E-05 : 2.05E-03  : 5.48E-09 : 0.OOE+00

+----- +------------------------------

CHILD  : 1.43E-05 : 1.47E-05  : 2.91E-05  : 1.47E-05  : 2.02E-05 : 4.04E-03  : 8.42E-09 : 0.OOE+00


+------------------------------ ------------- +------------------------------

INFANT : 2.53E-05 : 1.31E-05  : 5.77E-05  : 3.49E-05 : 3.51E-05 : 9.83E-03  : 1.52E-08  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :

ADULT  : 3.22E-06 4.53E-06 1.11E-05 4.94E-06 8.19E-06 1.55E-03 7.95E-09 O.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 5.38E-06 : 5.77E-06  : 2.04E-05  : 8.76E-06  : 1.46E-05 : 2.46E-03  : 1.64E-08 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.02E-05 : 4.28E-06  : 5.03E-05  : 1.52E-05 : 2.43E-05 : 4.85E-03  : 2.52E-08  : O.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 1.91E-05 : 4.08E-06  : 9.83E-05 : 3.70E-05  : 4.22E-05 : 1.18E-02  : 4.57E-08  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  :  :  :

ADULT 4.16E-07 6.10E-06 4.93E-07 4.99E-07 5.24E-07 9.07E-05 1.05E-04 O.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 5.51E-07  : 1.15E-05  : 7.OOE-07 : 6.74E-07  : 7.21E-07  : 1.12E-04  : 1.55E-04  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 6.15E-07  : 6.17E-05  : 9.60E-07 : 6.33E-07  : 6.77E-07 : 1.27E-04  : 1.26E-04  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 3.66E-07  : 5.35E-05  : 6.88E-07 : 5.17E-07  : 4.45E-07 : 1.16E-04  : 8.36E-05  : 0.OOE+00


+---------------+---------------+-- ------------------------ +---------------

TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 3 A Nearest Resident AT .90 MILES NW ANNUAL BETA AIR DOSE = 6.68E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 1.OOE-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 6.72E-05 : 6.72E-05 : 6.72E-05 : 6.72E-05 : 6.72E-05  : 6.72E-05  : 6.79E-05  : 1.35E-04 S+--------


+---------------+------------------------

GROUND  : 1.10E-03 : 1.10E-03 : 1.10E-03 : 1.10E-03 : 1.10E-03 1.10E-03 : 1.10E-03 : 1.30E-03

-+-------+-------+------------+---------------+---------------+---------------+------ --------- +---


+

VEGET  :  :  :  :  :  :

ADULT 1.95E-05 1.48E-04 4.32E-05 1.06E-05 5.14E-06 9.76E-04 8.60E-09 0.OOE+00

+--------------------+---------------+---------------+---------------+---  : ------------ +---------------+---------------+

TEEN  : 3.04E-05 : 1.59E-04 : 7.14E-05 : 1.62E-05 : 7.82E-06 : 1.32E-03 : 1.61E-08 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 6.14E-05 : 1.05E-04 : 1.74E-04 : 2.56E-05 : 1.26E-05 : 2.52E-03 : 2.45E-08 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  : "  : "  :

ADULT 4.53E-06 3.82E-05 4.60E-07 2.11E-06 1.40E-07 2.63E-05 7.01E-10 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.59E-06 : 2.05E-05 : 3.87E-07 : 1.64E-06 : 1.14E-07 : 1.91E-05 : 6.64E-10 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 5.58E-06 : 1.04E-05 : 7.31E-07 : 1.96E-06 : 1.45E-07 : 2.88E-05 : 7.80E-10 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  :  :

ADULT 2.34E-06 9.23E-06 3.52E-06 2.73E-06 3.86E-06 7.29E-04 5.93E-09 0.OOE+00

- +-+------------------------------+--------------- - -----------------------

++ +---------------+

TEEN  : 3.95E-06 : 1.10E-05 : 6.44E-06  : 4.82E-06 : 6.88E-06  : 1.15E-03  : 1.23E-08  : 0.OOE+00


-------------------------------- +--------------- -----


+---------------+---------------

CHILD  : 7.63E-06 : 7.43E-06 : 1.58E-05 : 8.26E-06 : 1.14E-05 : 2.28E-03 : 1.88E-08 : O.OOE+00 S---*---------------------------------+--------------- -----


+---------------+---------------

INFANT  : 1.35E-05 : 6.63E-06 : 3.12E-05 : 1.96E-05 : 1.99E-05 : 5.54E-03 : 3.41E-08 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :  :

ADULT  : 1.87E-06 2.37E-06 6.01E-06 2.90E-06 4.66E-06 8.75E-04 1.78E-08 O.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.06E-06 : 3.03E-06 : 1.10E-05 : 5.14E-06 : 8.31E-06 : 1.38E-03 : 3.68E-08 : 0.OOE+00 S---*--------------------------------------------------------------+------------------------------

CHILD  : 5.72E-06 : 2.26E-06 : 2.71E-05 : 8.94E-06 : 1.38E-05 : 2.74E-03 : 5.65E-08 : 0.OOE+00 S----++-------------------------------+---------------+-- -------- ---------------- +---------------+

INFANT  : 1.07E-05 : 2.16E-06 : 5.29E-05 : 2.16E-05 : 2.40E-05 : 6.65E-03 : 1.02E-07 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  :  :  :  :

ADULT 1.21E-07 1.52E-06 1.44E-07 1.50E-07 1.58E-07 2.61E-05 2.83E-05 O.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.60E-07 : 1.87E-06 : 2.04E-07 : 2.02E-07 : 2.17E-07 : 3.24E-05 : 4.15E-05 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.79E-07 : 5.26E-06 : 2.80E-07 : 1.91E-07 : 2.04E-07 : 3.67E-05 : 3.38E-05 : 0.OOE+00 IAN ---- 0----------------- --------------

0---------------1. ------- 0----------------1---------------+

INFANT :1.O8E-07 :4.38E-06 :2.01E-07 :1.57E-07 :1.34E-07 :3.35E-05 :2.19E-05 :O.OOE+00

-+-------+---------+---------------+---------------+---------------+---------------+---------------+---------------+

TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 1.60E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 2.68E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+--------------- +------------------------- +---------------+

PLUME  : 1.80E-05 : 1.80E-05 : 1.80E-05 : 1.80E-05 : 1.80E-05 : 1.80E-05 : 1.81E-05 : 3.49E-05

  • ----------------------+---------------+

GROUND  : 2.21E-05 : 2.21E-05 : 2.21E-05 : 2.21E-05 : 2.21E-05 : 2.21E-05 : 2.21E-05 : 2.60E-05


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  : . .  :  :  :

ADULT 3.94E-07 2.98E-06 8.87E-07 2.17E-07 1.11E-07 2.10E-05 2.65E-10 0.OOE+00


. +------------------------------------------------ *--* --- - ---------------- +---------------+

TEEN  : 6.13E-07 : 3.19E-06 : 1.47E-06 : 3.32E-07 : 1.69E-07 : 2.84E-05 : 4.97E-10  : 0.OOE+00


+---------------+-- ----------------------- +---------------+

CHILD  : 1.24E-06 : 2.11E-06 : 3.58E-06 : 5.26E-07 : 2.72E-07 : 5.44E-05 : 7.56E-10  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  :  :  :  :  :

ADULT 9.08E-08 7.64E-07 9.53E-09 4.25E-08 3.03E-09 5.67E-07 2.16E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 7.19E-08  : 4.11E-07  : 8.03E-09  : 3.30E-08  : 2.48E-09 : 4.11E-07  : 2.05E-1I  : 0.OOE+00


+----------------+------------------------------ -----------------------

++ +---------------+

CHILD  : 1.12E-07  : 2.08E-07  : 1.51E-08  : 3.94E-08  : 3.15E-09  : 6.20E-07  : 2.41E-11 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  : .

, ADULT  : 4.92E-08 1.86E-07 7.42E-08 5.88E-08 8.34E-08 1.57E-05 1.83E-10 0.OOE+00

-- - - -------------------- +---------------+---------------+---------------+---------------+---------------+---------------+

00 TEEN  : 8.27E-08  : 2.22E-07 : 1.36E-07  : 1.04E-07  : 1.49E-07  : 2.49E-05  : 3.78E-10 : 0.OOE+00

+---*-----------------+----------------------------------------------------------+---------------+

CHILD  : 1.59E-07 : 1.50E-07 : 3.33E-07 : 1.78E-07 : 2.47E-07 : 4.92E-05 : 5.81E-10 : 0.00E+00


+---------------------------------------------------------+---------------+

INFANT : 2.83E-07 : 1.34E-07 : 6.59E-07 : 4.23E-07 : 4.30E-07 : 1.20E-04 : 1.05E-09 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :  :

ADULT  : 4.09E-08 4.90E-08 1.26E-07 6.39E-08 1.01E-07 1.89E-05 5.49E-10 0.OOE+00


+----------------------------------------------------------+---------------

TEEN  : 6.64E-08  : 6.27E-08  : 2.32E-07  : 1.13E-07  : 1.80E-07  : 2.99E-05  : 1.13E-09 : 0.OOE+00


+----------------+---------------------------------------------------------+---------------

CHILD  : 1.23E-07 : 4.68E-08 : 5.69E-07 : 1.97E-07 : 3.OOE-07 : 5.90E-05 : 1.74E-09 : 0.OOE+00


+----------------------------------------------------------+---------------

INFANT : 2.28E-07 : 4.48E-08 : 1.11E-06 : 4.74E-07 : 5.21E-07 : 1.43E-04 : 3.15E-09 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  :  :  :  :

ADULT 8.OOE-09 7.92E-08 9.85E-09 1.14E-08 1.27E-08 1.80E-06 1.43E-06 0.OOE+00

+------------------------------+------------------------------ +-------------------- ---------------

TEEN  : 1.06E-08  : 9.34E-08  : 1.39E-08  : 1.55E-08  : 1.75E-08  : 2.24E-06  : 2.09E-06 : 0.OOE+00


+----------------------------------------------------------+---------------

CHILD  : 1.20E-08  : 2.25E-07  : 1.91E-08  : 1.48E-08  : 1.64E-08  : 2.55E-06  : 1.70E-06  : 0.OOE+00

+---------------------------+------------------------------------------------------ +---------------

INFANT : 7.56E-09  : 1.86E-07  : 1.40E-08  : 1.27E-08  : 1.08E-08  : 2.34E-06  : 1.10E-06  : 0.OOE+00


+----------------------------------------------------------+---------------

TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 5 A Nearest Garden AT 1.30 MILES SW ANNUAL BETA AIR DOSE = 2.63E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 4.08E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+---------------+---------------+--------------- ---------- --------------- +

PLUME 2.73E-05 : 2.73E-05 : 2.73E-05 : 2.73E-05 : 2.73E-05 : 2.73E-05 : 2.76E-05 : 5.43E-05


+---------------------------------------------------------+---------------+

GROUND  : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.39E-04


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  : .  :

ADULT 2.11E-06 1.60E-05 4.74E-06 1.16E-06 5.91E-07 1.12E-04 1.28E-09 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.29E-06  : 1.71E-05  : 7.84E-06 : 1.78E-06  : 8.99E-07  : 1.51E-04  : 2.40E-09 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 6.64E-06 : 1.13E-05  : 1.91E-05  : 2.81E-06  : 1.45E-06  : 2.89E-04  : 3.65E-09  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT . . .  :  :

ADULT 4.87E-07 4.10E-06 5.08E-08 2.28E-07 1.61E-08 3.02E-06 1.04E-10 0.OOE+00


+---------------------------------------------------------+---------------+

TEEN  : 3.86E-07  : 2.21E-06  : 4.28E-08 : 1.77E-07  : 1.32E-08  : 2.19E-06  : 9.89E-11  : O.OOE+00


+---------------------------------------------------------+---------------+

CHILD  : 6.OOE-07  : 1.12E-06  : 8.08E-08  : 2.12E-07 : 1.67E-08  : 3.30E-06  : 1.16E-10  : 0.OOE+00


+---------------+--------------- ++------- ------------------------------

COW MILK  : .  : .  :

ADULT  : 2.63E-07 9.97E-07 3.95E-07 3.13E-07 4.44E-07 8.37E-05 8.83E-10 0.OOE+00


+----------------+------------------------------ -------------------------- +---------------+

V TEEN  : 4.41E-07 : 1.19E-06 : 7.23E-07 : 5.51E-07 : 7.92E-07 : 1.32E-04 : 1.83E-09 : 0.OOE+00


+---------------+---------------+----+------- ------------------------------

CHILD  : 8.50E-07 : 8.04E-07 : 1.77E-06 : 9.46E-07 : 1.32E-06 : 2.62E-04 : 2.81E-09 : 0.OOE+00 :


+---------------+---------------+----+------- ------------------------------

INFANT : 1.51E-06 : 7.18E-07 : 3.51E-06 : 2.25E-06 : 2.29E-06 : 6.36E-04 : 5.08E-09 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  : . .  :

ADULT  : 2.17E-07 2.62E-07 6.73E-07 3.38E-07 5.37E-07 1.OOE-04 2.65E-09 0.OOE+00


+---------------+---------------+-------

7--------+---------------+---------------+---------------+

TEEN  : 3.52E-07 : 3.36E-07 : 1.23E-06 : 6.OOE-07 : 9.59E-07 : 1.59E-04  : 5.48E-09  : 0.OOE+00


+-------+-------------+---------------+---------------+---------------+-----------+---------------+---------------+

CHILD  : 6.53E-07 : 2.50E-07 : 3.03E-06 : 1.04E-06 : 1.59E-06 : 3.14E-04  : 8.42E-09 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 1.22E-06 : 2.40E-07 : 5.92E-06 : 2.51E-06 : 2.77E-06 : 7.64E-04  : 1.52E-08 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL .  :  : - .

ADULT 3.19E-08 4.33E-07 3.84E-08 4.07E-08 4.38E-08 6.99E-06 7.32E-06 0.OOE+00


+---------------+--------------- +--------- 7 ---------------- +

TEEN  : 4.23E-08 : 8.22E-07 : 5.44E-08 : 5.51E-08 : 6.02E-08 : 8.68E-06 : 1.08E-05  : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

CHILD  : 4.74E-08 : 4.46E-06 : 7.45E-08 : 5.21E-08 : 5.65E-08 : 9.84E-06 : 8.80E-06  : O.OOE+00


+------------------------------+--------------- +------------------------+---------------+

INFANT : 2.88E-08 : 3.87E-06 : 5.39E-08 : 4.35E-08 : 3.72E-08 : 9.OOE-06 : 5.83E-06  : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2009 SPECIAL LOCATION NO. 1 A Site Boundary AT .80 MILES S ANNUAL BETA AIR DOSE = 1.02E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 8.16E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+---------------+---------------+---------------+--------------- --------------------------

PLUME  : 5.34E-04 : 5.34E-04  : 5.34E-04  : 5.34E-04  : 5.34E-04  : 5.34E-04 : 5.45E-04  : 1.28E-03


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 2.42E-03 : 2.42E-03 : 2.42E-03  : 2.42E-03  : 2.42E-03  : 2.42E-03 : 2.42E-03  : 2.85E-03


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :  :

ADULT 5.43E-05 3.57E-04 2.77E-04 :3.47E-05 3.10E-05 5.91E-03 2.65E-09 0.OOE+00


+------------------------------+---------------+--------------- ---------------------------

TEEN  : 8.43E-05 : 3.88E-04  : 4.58E-04  : 5.29E-05  : 4.71E-05  : 7.97E-03 : 4.97E-09 : 0.OOE+00


+------------------------------+--------------- +--------- ---------------- +---------------

CHILD  : 1.72E-04  : 2.61E-04  : 1.12E-03  : 8.55E-05  : 7.60E-05  : 1.53E-02 : 7.56E-09  : 0.OOE+00

-+--------------------+---------------+--------------- - -+------- + ------------------------------

NEAT  : . .  :  :

ADULT 1.02E-05 8.42E-05 2.90E-06 4.94E-06 8.36E-07 1.60E-04 2.16E-10 0.OOE+00 S-----+ ------------------------------- +---------------+-------------------------------------------+

TEEN  : 8.05E-06 : 4.53E-05  : 2.45E-06  : 3.85E-06  : 6.83E-07  : 1.16E-04  : 2.05E-10  : 0.OOE+00


+------------------------------+--------------- -----------------------

+ +---------------+

CHILD  : 1.25E-05 : 2.29E-05 : 4.62E-06 : 4.63E-06 : 8.67E-07 : 1.74E-04 : 2.41E-10 : 0.OOE+00:


+------------------------------- -------------- + + ------------------------------ +-------

COW MILK  :  :  :

ADULT  : 1.02E-05 2.38E-05 2.18E-05 1.45E-05 2.31E-05 4.41E-03 1.83E-09 0.OOE+00

+-----------------------------------------------------+-------------------------------------------+

TEEN  : 1.72E-05 : 2.89E-05 : 3.98E-05 : 2.56E-05 : 4.12E-05  : 6.97E-03 : 3.78E-09 : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

CHILD  : 3.28E-05 : 2.01E-05 : 9.78E-05 : 4.43E-05  : 6.85E-05  : 1.38E-02 : 5.81E-09 : 0.OOE+00


+------------------------------+---------------------------- ----------------------------- +

INFANT  : 6.02E-05 : 1.83E-05 : 1.94E-04  : 1.07E-04  : 1.19E-04  : 3.35E-02 : 1.05E-08 : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

GOATMILK  :  :  :  :  :

ADULT  : 1.03E-05 1.07E-05 3.72E-05 1.63E-05 2.77E-05 5.29E-03 5.49E-09 O.OOE+00


+---------------- -----------------------

+ +---------------+

TEEN  : 1.72E-05 : 1.40E-05 : 6.83E-05 : 2.90E-05 : 4.95E-05 : 8.37E-03 : 1.13E-08 : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

CHILD  : 3.27E-05 : 1.08E-05 : 1.68E-04 : 5.05E-05 : 8.23E-05 : 1.65E-02 : 1.74E-08 : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

INFANT : 6.17E-05 : 1.05E-05 : 3.29E-04 : 1.23E-04 : 1.43E-04 : 4.02E-02 : 3.15E-08  : O.OOE+00


+------------------------------+--------------- +------------------------+---------------+

INHAL  :  :

ADULT 7.35E-07 7.01E-06 1.49E-06 1.02E-06 1.40E-06 2.56E-04 1.13E-04 0.OOE+00


+------------------------------+--------------- +-------- -------------- ++-------------

TEEN  : 9.67E-07 : 1.11E-05 : 2.11E-06 : 1.39E-06 : 1.92E-06 : 3.16E-04 : 1.67E-04 : O.OOE+00


+------------------------------+--------------- +------------------------+---------------+

CHILD  : 1.06E-06 : 4.88E-05  : 2.89E-06  : 1.34E-06  : 1.80E-06  : 3.54E-04  : 1.37E-04 : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

INFANT : 6.78E-07 : 4.18E-05 : 2.06E-06 : 1.16E-06 : 1.19E-06 : 3.23E-04 : 9.09E-05 : 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 2 A Site Boundary AT .67 MILES N ANNUAL BETA AIR DOSE = 1.44E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.05E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


-*-+------------------------------+---------------+--------------- ---------

+ +---------------

PLUME  : 6.87E-04 : 6.87E-04 : 6.87E-04 : 6.87E-04 : 6.87E-04 : 6.87E-04 : 7.02E-04 : 1.71E-03 :


+---------------+---------------+---------------+---------------+---------------+-------------

GROUND  : 3.17E-03 : 3.17E-03 : 3.17E-03 : 3.17E-03 : 3.17E-03 : 3.17E-03 : 3.17E-03 : 3.73E-03 :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :

ADULT. 7.09E-05 4.68E-04 3.62E-04 4.50E-05 3.98E-05 7.60E-03 2.93E-09 0.OOE+00

+-------------------+-------- ------- +---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.10E-04  : 5.08E-04  : 5.99E-04  : 6.86E-05  : 6.06E-05  : 1.02E-02 : 5.48E-09  : 0.OOE+00  :

-+---


+---------------+---------------+---------------+---------------+----- + ----------

CHILD  : 2.24E-04  : 3.42E-04  : 1.46E-03  : 1.11E-04  : 9.77E-05  : 1.96E-02 : 8.34E-09  : 0.OOE+00  :


+---------------+---------------+---------------+---------------+---------------+---------------+

HEAT  :  :  :

ADULT 1.33E-05 1.10E-04 3.79E-06 6.46E-06 1.07E-06 2.05E-04 2.39E-10 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN 1.05E-05 : 5.93E-05 : 3.20E-06 : 5.03E-06 : 8.77E-07 : 1.49E-04 : 2.26E-10 : 0OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.64E-05 : 3.OOE-05 : 6.04E-06 : 6.05E-06 : 1.11E-06 : 2.24E-04 : 2.66E-10 : 0.OOE+00  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :

ADULT  : 1.32E-05 3.11E-05 2.83E-05 1.86E-05 2.97E-05 5.67E-03 2.02E-09 0.OOE+00 TEEN  : 2.22E-05 : 3.78E-05 : 5.18E-05  : 3.30E-05  : 5.30E-05  : 8.96E-03 : 4.17E-09  : 0.OOE+00  :

- ---------------------------------------------------------------- +---------------+---------------

CHILD  :,4.24E-05  : 2.62E-05 : 1.27E-04 : 5.71E-05 : 8.81E-05 : 1.77E-02 : 6.41E-09 : 0.OOE+00.:

S------------------- ----------------- +---------------+----------------- +--------- +---------------

INFANT  : 7.78E-05 : 2.39E-05 : 2.51E-04 : 1.38E-04 : 1.53E-04 : 4.30E-02 : 1.16E-08 : 0.OOE+00

-+-+------------------+------------------------------ ----------------------------- +---------------

GOATMILK  :  :  : .  :

ADULT  : 1.32E-05 1.39E-05 4.85E-05 2.10E-05 3.57E-05 6.80E-03 6.06E-09 0.OOE+00

- -S+-- ------------------------------------------------------------ +---------------+---------------

TEEN  : 2.22E-05 : 1.82E-05 : 8.89E-05 : 3.73E-05  : 6.36E-05  : 1.08E-02 : 1.25E-08  : 0.OOE+00  :

- ------------------- --------------- +---------------- ---- .- +----- - +----------------+-------------

CHILD  : 4.22E-05 : 1.40E-05 : 2.19E-04 : 6.49E-05 : 1.06E-04 : 2.12E-02  : 1.92E-08  : O.OOE+00 :

- - S--- -------------------------------- +--------------- +---------- ++------------------------------

INFANT  : 7.95E-05 : 1.37E-05 : 4.28E-04 : 1.59E-04 : 1.84E-04 : 5.16E-02  : 3.48E-08  : 0.OOE+00  :

- - S+-- -------------------------------- +--------------- +---------- ++------------------------------

INHAL  :  :  :  :  :

ADULT 1.12E-06 1.15E-05 2.27E-06 1.55E-06 2.11E-06 3.86E-04 1.78E-04 O.OOE+00

- -S+-- -------------------------------- +--------------- +-------

--- ++------------------------------

TEEN  : 1.47E-06 : 2.22E-05 : 3.23E-06 : 2.11E-06 : 2.90E-06 : 4.76E-04  : 2.63E-04  : 0.OOE+00  :

S-------------------------------------+--------------- +---------- ++------------------------------

CHILD  : 1.61E-06 : 1.20E-04 : 4.43E-06 : 2.02E-06 : 2.72E-06 : 5.34E-04  : 2.15E-04  : 0.OOE+00  :

- - S+-- -------------------------------- +--------------- +---------- ++------------------------------

INFANT  : 1.03E-06 : 1.04E-04 : 3.15E-06 : 1.76E-06 : 1.79E-06 : 4.88E-04  : 1.45E-04  : 0.00E+00  :

-+-+------------------+------------------------------ ----------------------------- +---------------

TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 3 A Nearest Resident AT .90 MILES NW ANNUAL BETA AIR DOSE = 1.34E-03 MILLRADS ANNUAL GAMMA AIR DOSE = l.74E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+-------+-------------+---------------+---------------+---------------+-----------+---------------+---------------+

PLUME  : 1.16E-03 : 1.16E-03 : 1.16E-03 : 1.16E-03 : 1.16E-03 : 1.16E-03 : 1.18E-03 : 2.37E-03

..... ---.... ------------------------------------------------ +-----------+--------- +--------------

GROUND  : 1.45E-03  : 1.45E-03  : 1.45E-03  : 1.45E-03  : 1.45E-03  : 1.45E-03 : 1.45E-03  : 1.70E-03

.+..- -...- +------------------------------4--------------- --------- -+------------------------------

VEGET  :  :  :  : .

ADULT 3.50E-05 2.14E-04 1.69E-04 2.51E-05 2.60E-05 4.96E-03 6.31E-09 0.OOE+00

-.---- +--------------------------------------------------------------+----------------------------

TEEN  : 5.39E-05 : 2.33E-04 : 2.80E-04 : 3.82E-05 : 3.96E-05 : 6.69E-03 : 1.18E-08 : 0.OOE+00 S-------------------------------------------------------------------------------------------------

CHILD  : 1.09E-04 : 1.57E-04 : 6.83E-04 : 6.23E-05 : 6.38E-05 : 1.28E-02 : 1.80E-08 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

HEAT  :  :

ADULT 6.13E-06 5.02E-05 1.83E-06 3.07E-06 7.03E-07 1.34E-04 5.15E-10 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 4.85E-06 : 2.70E-05 : 1.54E-06 : 2.40E-06 : 5.74E-07 : 9.70E-05 : 4.87E-10 0.OOE+00

- - S+---------------------------------- +--------------- -----


+---------------+---------------

CHILD  : 7.53E-06 : 1.37E-05 : 2.91E-06 : 2.89E-06 : 7.29E-07 : 1.46E-04 : 5.73E-10 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  : .  :  :

ADULT  : 7.99E-06 1.51E-05 1.54E-05 1.19E-05 1.94E-05 3.70E-03 4.35E-09 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.34E-05 : 1.84E-05  : 2.81E-05  : 2.12E-05 : 3.46E-05  : 5.85E-03  : 9.OOE-09  : 0.OOE+00

+-++------------------+------------------------------ ----------------------------- +---------------

CHILD  : 2.54E-05 : 1.29E-05 : 6.88E-05 : 3.67E-05 : 5.76E-05 : 1.16E-02 : 1.38E-08 : 0.OOE+00

- - S+------------------------------------------------- ----------------------------- +---------------

INFANT : 4.68E-05 : 1.18E-05 : 1.37E-04 : 8.90E-05 : 1.OOE-04 : 2.81E-02 : 2.50E-08 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :

ADULT 8.45E-06 7.42E-06 2.51E-05 1.38E-05 2.33E-05 4.44E-03 1.31E-08 0.OOE+00

+-- +--------------------------------------------

TEEN  : 1.41E-05 : 9.78E-06 : 4.61E-05 : 2.44E-05  : 4.16E-05  : 7.03E-03  : 2.70E-08  : 0.OOE+00

- - S+------------------------------------------------- ----------------------------- +---------------

CHILD  : 2.65E-05 : 7.56E-06 : 1.13E-04 : 4.26E-05  : 6.91E-05  : 1.39E-02  : 4.15E-08  : 0.OOE+00

-- *+------------------------------------------------- ----------------------------- +---------------

INFANT : 5.OOE-05 : 7.39E-06 : 2.23E-04 : 1.04E-04 : 1.20E-04 : 3.37E-02 : 7.50E-08 : O.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  : .  :  :  :

ADULT 3.45E-07 3.18E-06 6.70E-07 4.96E-07 6.87E-07 1.24E-04 4.85E-05 0.OOE+00

- +*------------------+---------------+---------------+--------- ---------------- +---------------+

TEEN  : 4.53E-07  : 6.14E-06 : 9.51E-07 : 6.76E-07 : 9.43E-07 : 1.53E-04 : 7.19E-05 : 0.OOE+00

- - S+-- --------------------------------------------------------------------------------------------

CHILD  : 4.96E-07 : 3.34E-05 : 1.30E-06 : 6.50E-07 : 8.85E-07 : 1.71E-04 : 5.88E-05 : 0.OOE+00

- ----- ----------------- ++ +---------------+--------------- +


--------------- +

INFANT : 3.21E-07 : 2.90E-05 : 9.33E-07 : 5.70E-07 : 5.82E-07 : 1.56E-04 : 3.97E-05 : 0.OOE+00

-+-------------------+---------------+--------------- +-------------------------------------------

TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 4.54E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 6.76E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 4.54E-04  : 4.54E-04  : 4.54E-04  : 4.54E-04  : 4.54E-04  : 4.54E-04  : 4.59E-04 : 8.93E-04


+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 4.17E-05  : 4.17E-05  : 4.17E-05 : 4.17E-05  : 4.17E-05  : 4.17E-05  : 4.17E-05 : 4.91E-05


+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :

ADULT 1.09E-06 6.23E-06 5.02E-06 8.61E-07 9.84E-07 1.88E-04 3.29E-10 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.67E-06  : 6.77E-06  : 8.29E-06 : 1.31E-06  : 1.50E-06  : 2.53E-04  : 6.17E-10 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 3.35E-06  : 4.57E-06  : 2.02E-05 : 2.15E-06 : 2.41E-06  : 4.85E-04  : 9.38E-10 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  : - . . .

ADULT 1.79E-07 1.45E-06 5.58E-08 9.23E-08 2.66E-08 5.07E-06 2.69E-11 0.OOE+00


+--------------- -----


+---------------+---------------

TEEN  : 1.42E-07 : 7.81E-07  : 4.70E-08 : 7.22E-08  : 2.17E-08 : 3.67E-06  : 2.54E-11  : o.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 2.20E-07 : 3.95E-07  : 8.86E-08 : 8.75E-08  : 2.76E-08 : 5.54E-06 : 2.99E-l1 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  :

a ADULT  : 2.89E-07 4.62E-07 5.16E-07 4.47E-07 7.34E-07 1.40E-04 2.27E-10 0.OOE+00 t'------------+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 4.84E-07  : 5.68E-07  : 9.43E-07  : 7.92E-07  : 1.31E-06 : 2.21E-04  : 4.69E-10 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 9.10E-07  : 4.01E-07  : 2.31E-06  : 1.37E-06  : 2.18E-06 : 4.37E-04  : 7.21E-10  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 1.69E-06  : 3.69E-07  : 4.63E-06 : 3.34E-06  : 3.79E-06 : 1.06E-03  : 1.31E-09  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :

ADULT  : 3.15E-07 2.47E-07 8.16E-07 5.22E-07 8.82E-07 1.68E-04 6.81E-10 0.OOE+00


+--------------- -----


+---------------+---------------

TEEN  : 5.24E-07 : 3.26E-07  : 1.49E-06 : 9.26E-07  : 1.57E-06 : 2.66E-04  : 1.41E-09  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 9.79E-07 : 2.53E-07  : 3.67E-06  : 1.61E-06  : 2.62E-06 : 5.25E-04  : 2.16E-09  : 0.OOE+00 INFANT : 1.85E-06 : 2.47E-07  : 7.26E-06 : 3.93E-06  : 4.55E-06 : 1.27E-03  : 3.92E-09  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  :  :  :

ADULT 3.78E-08 2.25E-07 6.31E-08 6.02E-08 8.70E-08 1.51E-05 3.26E-06 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 4.96E-08 : 4.45E-07 : 8.94E-08 : 8.24E-08 : 1.19E-07 : 1.86E-05 : 4.84E-06 : 0.OOE+00


+---------------+---------------

CHILD  : 5.41E-08 : 2.46E-06 : 1.22E-07 : 7.99E-08 : 1.12E-07 : 2.08E-05 : 3.96E-06 : 0.OOE+00


T- --------------

0--------------- 0--------------- 0---------------0------------------------+

INFANT :3.65E-08 :2.14E-06 :8.99E-08 :7.18E-08 :7.38E-08 :1.90E-05S 2.68E-06 :0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2009 (Continued)

SPECIAL LOCATION NO. 5 A Nearest Garden AT 1.30 MILES SW ANNUAL BETA AIR DOSE = 5.97E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 8.44E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

+---*---------------------------------+---------------+--------------- --------------------------- +

PLUME  : 5.66E-04 : 5.66E-04 : 5.66E-04 : 5.66E-04 : 5.66E-04 : 5.66E-04 : 5.72E-04  : 1.13E-03


+------------------------------+--------------- ------------------------------------------ +

GROUND  : 1.80E-04 : 1.80E-04 : 1.80E-04 : 1.80E-04 : 1.80E-04 : 1.80E-04 : 1.80E-04  : 2.11E-04


+------------------------------+--------------- ------------------------------------------ +

VEGET  :

ADULT 4.61E-06 2.68E-05 2.15E-05 3.58E-06 4.02E-06 7.66E-04 1.28E-09 0.OOE+00


+----------------------------------------------------------------------------------------+

TEEN  : 7.08E-06 : 2.91E-05 : 3.55E-05 : 5.45E-06 : 6.11E-06 : 1.03E-03 : 2.40E-09 : O.OOE+00


+------------------------------+--------------- ------------------------------------------ +

CHILD  : 1.42E-05 : 1.96E-05 : 8.66E-05 : 8.93E-06 : 9.86E-06 : 1.98E-03 : 3.65E-09 : 0.OOE+00


+-+------------------------- L-- +-----------------------------------------------------------+

MEAT  :  :  :  :  :

ADULT 7.69E-07 6.24E-06 2.38E-07 3.94E-07 1.09E-07 2.07E-05 1.04E-10 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

TEEN  : 6.08E-07 : 3.36E-06 : 2.OOE-07 : 3.08E-07 : 8.87E-08 : 1.50E-05 : 9.89E-11  : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

CHILD  : 9.43E-07  : 1.70E-06  : 3.77E-07  : 3.73E-07  : 1.13E-07  : 2.26E-05  : 1.16E-10  : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

COW MILKl::  : .  :  :

ADULT  : 1.19E-06 1.96E-06 2.15E-06 1.83E-06 3.OOE-06 5.72E-04 8.83E-10 0.OOE+00

- + -------------------------- +----------------------------------------------------------+

TEEN  : 1.99E-06  : 2.41E-06  : 3.93E-06  : 3.24E-06 : 5.35E-06  : 9.04E-04  : 1.83E-09  : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

CHILD  : 3.75E-06  : 1.70E-06  : 9.63E-06  : 5.62E-06 : 8.89E-06 : 1.79E-03  : 2.81E-09 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

INFANT : 6.95E-06  : 1.56E-06  : 1.93E-05  : 1.37E-05  : 1.55E-05 : 4.34E-03  : 5.08E-09 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

GOATMILK  :  : .  :  :

ADULT  : 1.29E-06 1.03E-06 3.43E-06 2.13E-06 3.60E-06 6.86E-04 2.65E-09 0.OOE+00

+---------------------------+---------------+---------------+- ----- ----------------------------- +

TEEN  : 2.15E-06 : 1.36E-06 : 6.28E-06 : 3.78E-06 : 6.43E-06 : 1.08E-03 : 5.48E-09 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

CHILD  : 4.01E-06 : 1.06E-06 : 1.54E-05 : 6.59E-06 : 1.07E-05 : 2.14E-03 : 8.42E-09 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

INFANT : 7.57E-06 : 1.03E-06 : 3.05E-05 : 1.61E-05 : 1.86E-05 : 5.21E-03 : 1.52E-08 : 0.OOE+00


+---------------------------------------------+--------------------- - ----- +

INHAL  ::

ADULT 9.09E-08 7.41E-07 1.69E-07 1.35E-07 1.90E-07 3.38E-05  : 1.12E-05 0.OOE+00

- ---- +------------------------------+---------------+-------------------------------------- ------- +

TEEN  : 1.19E-07 : 1.44E-06 : 2.39E-07  : 1.85E-07  : 2.61E-07  : 4.17E-05  :-1.66E-05  : 0.OOE+00


--------------------------------------------- +---------------+ ---------------------------- +

CHILD  : 1.30E-07 : 7.87E-06 : 3.27E-07  : 1.78E-07  : 2.45E-07  : 4.67E-05 : 1.36E-05 : 0.OOE+00


- ------ +-------------------------------------+

INFANT : 8.57E-08 : 6.83E-06 : 2.36E-07 : 1.58E-07 : 1.61E-07 : 4.27E-05 : 9.15E-06 : O.OOE+00

+---------------+------------------------------- ----------- +

TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2009 SPECIAL LOCATION NO. 1 A Site Boundary AT .67 MILES N ANNUAL BETA AIR DOSE = 5.52E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 2.11E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+------------------------------+------------------------------ --------------------------- +

PLUME  : 1.26E-04 : 1.26E-04 : 1.26E-04 : 1.26E-04 : 1.26E-04 : 1.26E-04 : 1.31E-04 : 3.42E-04


+------------------------------+----------------------------------------------------------+

GROUND  : 1.50E-03 : 1.50E-03 : 1.50E-03 : 1.50E-03 : 1.50E-03 : 1.50E-03 : 1.50E-03 : 1.76E-03


+------------------------------+--------------- ------------------------------------------ +

VEGET .  :  : .

ADULT 2.58E-05 2.02E-04 5.23E-05 1.43E-05 4.66E-06 6.54E-04 3.72E-10 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

TEEN  : 4.05E-05 : 2.17E-04 : 8.66E-05 : 2.18E-05 : 7.OOE-06 : 8.82E-04 : 6.26E-10  : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

CHILD  : 8.21E-05 : 1.43E-04 : 2.11E-04 : 3.38E-05 : 1.10E-05 : 1.69E-03 : 8.94E-10  : 0.OOE+00

+---*---------------------------------+--------------- ------------------------------------------- +

MEAT  :  :

ADULT 6.49E-06 5.22E-05 7.98E-07 3.67E-06 6.71E-07 1.76E-05 1.29E-11 0.OOE+00


+------------------------------+--------------- - + ------------------------------ +-------

TEEN  : 5.14E-06 : 2.81E-05 : 6.35E-07 : 2.84E-06 : 5.OOE-07 : 1.28E-05 : 1.11E-11 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

CHILD  : 7.99E-06 : 1.42E-05 : 1.13E-06 : 3.36E-06 : 5.77E-07 : 1.93E-05 : 1.23E-11 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

COW MILK :  :  :  :  :

ADULT  : 3.75E-06 1.42E-05 4.45E-06 5.44E-06 4.81E-06 4.90E-04 5.19E-11 0.OOE+00

+--------+-----------------------------------------------------------------------------------------

TEEN  : 6.44E-06 : 1.67E-05 : 7.85E-06 : 9.27E-06 : 8.18E-06 : 7.75E-04 : 9.76E-11 0.OOE+00


+------------------------------+--------------- +------------------------+---------------+

CHILD  : 1.28E-05 : 1.11E-05 : 1.85E-05 : 1.46E-05 : 1.29E-05 : 1.53E-03 : 1.41E-10 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

INFANT : 1.99E-05 : 2.08E-05 : 3.43E-05 : 2.92E-05 : 2.04E-05 : 3.72E-03 : 2.81E-10 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

GOATMILK  :  :  :  : .

ADULT  : 1.51E-06 2.89E-06 6.33E-06 2.28E-06 3.37E-06 5.88E-04 6.23E-12 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

TEEN  : 2.56E-06  : 3.62E-06  : 1.16E-05  : 4.OOE-06  : 5.96E-06  : 9.30E-04  : 1.17E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 4.99E-06  : 2.63E-06  : 2.85E-05 : 6.80E-06  : 9.83E-06 : 1.84E-03  : 1.70E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 8.93E-06  : 3.79E-06  : 5.50E-05  : 1.58E-05  : 1.68E-05 : 4.47E-03  : 3.37E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  : - - -

ADULT 4.39E-07 6.39E-06 4.84E-07 5.18E-07 4.32E-07 6.51E-05 1.22E-04 O.OOE+00


+-----------------------------------------------------------------------------------------+

TEEN  : 5.85E-07 : 7.46E-06 : 6.85E-07 : 6.94E-07 : 5.91E-07 : 8.12E-05 : 1.78E-04 : O.OOE+00


+--------------------------------------------- ------------------------------------------- +

CHILD  : 6.59E-07 : 1.83E-05 : 9.36E-07 : 6.38E-07 : 5.50E-07 : 9.28E-05 : 1.45E-04 : 0.OOE+00


+----------------------------------------------------------------------------------------+

INFANT : 3.76E-07 : 1.50E-05 : 6.56E-07 : 4.87E-07 : 3.56E-07 : 8.50E-05 : 9.37E-05 : 0.OOE+00

+------------------------------------------+----------------+--------------------- --------------- +

TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2009 (Continued)

SPECIAL LOCATION NO. 2 A Site Boundary AT .60 MILES NNE ANNUAL BETA AIR DOSE = 4.16E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 1.51E-04 MILLRADS PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 8.92E-05 : 8.92E-05 : 8.92E-05 : 8.92E-05 : 8.92E-05  : 8.92E-05  : 9.34E-05  : 2.47E-04


+---------------+---------------+-------------------------+---------------+

GROUND  : 1.09E-03  : 1.09E-03 : 1.09E-03  : 1.09E-03  : 1.09E-03  : 1.09E-03  : 1.09E-03 : 1.28E-03

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  : .  :  :  :

ADULT 1.89E-05 1.48E-04 3.80E-05 1.04E-05 3.40E-06 4.78E-04 2.70E-10 0.OOE+00


+--------------------------------------------------------------------------

TEEN  : 2.96E-05  : 1.58E-04  : 6.29E-05 : 1.59E-05  : 5.11E-06  : 6.45E-04  : 4.54E-10 : 0.OOE+00

+ -------- +---------------+------------------------------ ----------- +------------------------------

CHILD  : 5.99E-05  : 1.04E-04  : 1.53E-04  : 2.47E-05  : 8.04E-06  : 1.24E-03  : 6.48E-10  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT .  :  :

ADULT 4.74E-06 3.81E-05 5.81E-07.: 2.68E-06 4.90E-07 1.29E-05 9.36E-12 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.76E-06  : 2.05E-05  : 4.62E-07 : 2.07E-06  : 3.66E-07 : 9.33E-06  : 8.06E-12 : 0.OOE+00

- +-------+~----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 5.83E-06 : 1.04E-05  : 8.19E-07  : 2.45E-06  : 4.22E-07  : 1.41E-05  : 8.92E-12  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK : .  :  :  :  :  :

,. ADULT  : 2.74E-06 1.03E-05 3.24E-06 3.97E-06 3.51E-06 3.58E-04 3.78E-11 0.OOE+00


+----------------+-----------------------------------------------------------------------

TEEN  : 4.70E-06 : 1.22E-05  : 5.72E-06  : 6.78E-06 : 5.98E-06 : 5.66E-04  : 7.10E-11 0.OOE+00

+ -------- +---------------+------------------------------------------ +


--------------- +

CHILD  : 9.36E-06 : 8.09E-06  : 1.35E-05 : 1.07E-05 : 9.46E-06  : 1.12E-03  : 1.03E-10 : 0.OOE+00

+ -------- +---------------+---------------------------------------------+----------------------------

INFANT  : 1.45E-05 : 1.52E-05  : 2.50E-05  : 2.13E-05  : 1.49E-05  : 2.72E-03  : 2.04E-10  : 0.OOE+00

+-+---------"---------------+------------------------------ ----------------------- +---------------

GOATMILK :  :  : .

ADULT  : 1.10E-06 2.11E-06 4.60E-06 1.67E-06 2.46E-06 4.29E-04 4.53E-12 0.OOE+00

+ ----------------------- +---------------+--------------- +4-------- ---------------- +---------------

TEEN  : 1.87E-06 : 2.64E-06  : 8.43E-06 : 2.93E-06  : 4.35E-06  : 6.79E-04  : 8.52E-12  : 0.OOE+00

- +------------------------------+-------------------- ------------------------------- +-------------

CHILD  : 3.65E-06  : 1.91E-06  : 2.07E-05  : 4.97E-06 : 7.18E-06  : 1.34E-03  : 1.23E-11  : O.OOE+00

- +-------..--------.------------------------------------ -------------------------- +---------------

INFANT  : 6.52E-06 : 2.77E-06  : 4.OOE-05  : 1.16E-05 : 1.23E-05  : 3.26E-03  : 2.45E-11 0.OOE+00

+ ----------------------------------------------------------------------------------- +-------------

INHAL .  :  :  :  :

ADULT 3.54E-07 5.18E-06 3.90E-07 4.16E-07 3.43E-07 5.17E-05 9.88E-05 O.OOE+00

- +------.....-+-----------.---------------+----------------- ------- ------------------------------ +

TEEN  : 4.72E-07 : 6.05E-06  : 5.52E-07  : 5.57E-07  : 4.69E-07  : 6.45E-05  : 1.45E-04  : O.OOE+00

- +--------.....-+-...---------

-- ..... +------------------------------------------------------------+

CHILD  : 5.32E-07  : 1.48E-05  : 7.54E-07 : 5.12E-07  : 4.37E-07  : 7.37E-05  : 1.18E-04  : 0.OOE+00

+------------------------------------------- +--------------- +-------------------- --------------- +

INFANT  : 3.03E-07  : 1.22E-05  : 5.28E-07  : 3.90E-07 : 2.83E-07 : 6.75E-05  : 7.61E-05  : 0.OOE+00

++-----------------------------------------------------------------------------------+-------------+

TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2009 (Continued)

SPECIAL LOCATION NO. 3 A Nearest Resident AT .90 MILES NW ANNUAL BETA AIR DOSE = 2.01E-04 MILLRADS ANNUAL GAMMA AIR DOSE = l.40E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


......... -- -------------------------------- 7 ---------------------------------------------- +

PLUME  : 8.99E-05 : 8.99E-05 : 8.99E-05 : 8.99E-05 : 8.99E-05 : 8.99E-05 : 9.19E-05 : 2.06E-04


. +--.+-------------------------------+--------------- +------- ------------------------------

GROUND  : 7.81E-04 : 7.81E-04 : 7.81E-04 : 7.81E-04 : 7.81E-04 : 7.81E-04 : 7.81E-04 : 9.19E-04


+------------------------------+--------------- ------------------------------------------ +

VEGET  :  :  :  :

ADULT 1.35E-05 1.06E-04 2.82E-05 7.44E-06 2.42E-06 3.40E-04 2.01E-10 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 2.12E-05 : 1.13E-04 : 4.67E-05 : 1.14E-05 : 3.63E-06 : 4.58E-04  : 3.40E-10  : 0.OOE+00


+------------------------------ -- 4 - -------------------------------

+ * +-------------+

CHILD  : 4.30E-05 : 7.48E-05 : 1.14E-04 : 1.76E-05 : 5.72E-06 : 8.78E-04  : 4.86E-10  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

HEAT  :  :  : .

ADULT 3.39E-06 2.73E-05 4.25E-07 1.91E-06 3.49E-07 9.16E-06 7.OOE-12 0.OOE+00


+---------------+--


+---------------+

TEEN  : 2.69E-06 : 1.47E-05 : 3.38E-07 : 1.48E-06 : 2.60E-07 : 6.63E-06  : 6.05E-12  : 0.OOE+00


.-- + ------------------------------- +--------------- ----------------------- +---------------+

CHILD  : 4.17E-06 :.7.41E-06 : 6.01E-07 : 1.75E-06 : 3.OOE-07 : 1.OOE-05  : 6.71E-12  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  : . .

ADULT  : 1.95E-06 7.40E-06 2.36E-06 2.83E-06 2.50E-06 2.54E-04 2.77E-11 0.OOE+00


+---------------------------------------------+-------------+

TEEN  : 3.35E-06 : 8.72E-06  : 4.17E-06 : 4.82E-06 : 4.25E-06  : 4.02E-04  : 5.20E-11 0.OOE+00


+---------------+---------------+---------------+-----------+---------------+---------------+

CHILD  : 6.68E-06 : 5.79E-06  : 9.83E-06  : 7.61E-06 : 6.73E-06  : 7.95E-04  : 7.53E-11  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 1.04E-05 : 1.08E-05  : 1.82E-05 : 1.52E-05 : 1.06E-05  : 1.93E-03  : 1.50E-10  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  : .  :

ADULT  : 7.87E-07 1.52E-06 3.39E-06 1.18E-06 1.75E-06 3.05E-04 3.32E-12 O.OOE+00


+---------------------------------------------------------+---------------+

TEEN  : 1.34E-06 : 1.91E-06  : 6.21E-06  : 2.08E-06 : 3.09E-06  : 4.83E-04  : 6.24E-12 : 0.OOE+00


---------------------------- +---------------+

CHILD  : 2.61E-06  : 1.39E-06  : 1.52E-05 : 3.53E-06 : 5.10E-06 : 9.54E-04  : 9.04E-12  : O.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 4.67E-06  : 1.99E-06  : 2.94E-05 : 8.22E-06 : 8.74E-06  : 2.32E-03 : 1.80E-11  : O.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :

ADULT 8.24E-08 1.18E-06 9.16E-08 9.92E-08 8.24E-08 1.19E-05 2.21E-05 0.OOE+00

- ---------------------------------------------------- ---------------------------- +---------------+

TEEN  : 1.10E-07 : 1.41E-06 : 1.30E-07 : 1.33E-07 : 1.13E-07 : 1.48E-05  : 3.25E-05 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.24E-07 : 3.67E-06 : 1.77E-07 : 1.23E-07 : 1.05E-07 : 1.69E-05  : 2.64E-05 0.OOE+00


+---------------+-- ----------------------- +---------------+

INFANT : 7.15E-08 : 3.03E-06 : 1.25E-07 : 9.48E-08 : 6.81E-08 : 1.55E-05  : 1.71E-05 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2009 (Continued)

SPECIAL LOCATION NO. 4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 5.28E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 4.88E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE - LIVER KIDNEY THYROID LUNG SKIN

- +-----------+--------------- + --------------- +---------------+---------------+---------------+---------------+

PLUME  : 3.19E-05  : 3.19E-05  : 3.19E-05 : 3.19E-05 : 3.19E-05  : 3.19E-05 : 3.24E-05  : 6.95E-05

+--------+---------------------------------------------------------+------------------------------

GROUND  : 2.31E-05  : 2.31E-05  : 2.31E-05  : 2.31E-05 : 2.31E-05  : 2.31E-05 : 2.31E-05  : 2.72E-05

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :  :  :

ADULT 4.01E-07 3.14E-06 8.81E-07 2.19E-07 7.08E-08 9.94E-06 6.35E-12 0.OOE+00


+---------------+--------------- + ------------------- --------------- +

TEEN  : 6.29E-07  : 3.36E-06  : 1.46E-06 : 3.36E-07  : 1.06E-07  : 1.34E-05 : 1.07E-11  : O.OOE+00

+------------------------------------------------------------------+------------------------------

CHILD  : 1.28E-06  : 2.22E-06  : 3.56E-06 : 5.21E-07 : 1.67E-07  : 2.57E-05 : 1.54E-11 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  :  :  :  :

ADULT 1.OOE-07 8.07E-07 1.30E-08 5.65E-08 1.02E-08 2.68E-07 2.22E-13 0.OOE+00

+--------+------------------------------+--------------- ----------- +------------------------------

TEEN  : 7.94E-08 : 4.34E-07 : 1.04E-08 : 4.37E-08 : 7.61E-09  : 1.94E-07  : 1.92E-13  : O.OOE+00

+--------+------------------------------+--------------- ----------- +------------------------------

CHILD  : 1.23E-07 : 2.19E-07 : 1.85E-08 : 5.17E-08 : 8.78E-09  : 2.93E-07 : 2.14E-13  : 0.OOE+00

+--------------------------------------+--------------- -----


+---------------+---------------

COW MILK  :  :  :  :  :

ADULT  : 5.75E-08 2.19E-07 7.16E-08 8.28E-08 7.31E-08 7.44E-06 8.47E-13 0.OOE+00


+---------------+----------------------------

00 TEEN  : 9.87E-08 : 2.58E-07  : 1.27E-07  : 1.41E-07 : 1.24E-07  : 1.18E-05  : 1.59E-12  : 0.OOE+00

-+-----------------------------------------------------------------+------------------------------

CHILD  : 1.97E-07  : 1.71E-07  : 3.OOE-07  : 2.23E-07 : 1.97E-07  : 2.33E-05  : 2.31E-12  : 0.OOE+00

+--------+--------------------------------------------- -------------------------------------------

INFANT  : 3.05E-07  : 3.19E-07  : 5.56E-07 : 4.44E-07 : 3.10E-07  : 5.66E-05  : 4.61E-12  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :

ADULT  : 2.32E-08 4.57E-08 1.05E-07 3.47E-08 5.12E-08 8.93E-06 1.02E-13 0.OOE+00

+--------+------------------------------+--------------- ----------- +------------------------------

TEEN  : 3.94E-08  : 5.73E-08  : 1.92E-07 : 6.09E-08  : 9.05E-08  : 1.41E-05  : 1.91E-13  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 7.71E-08  : 4.17E-08  : 4.71E-07 : 1.03E-07 : 1.49E-07  : 2.79E-05  : 2.77E-13  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 1.38E-07  : 5.94E-08  : 9.08E-07  : 2.40E-07  : 2.56E-07  : 6.79E-05  : 5.53E-13  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  : .  :

ADULT 6.73E-09 8.95E-08 7.76E-09 8.78E-09 7.36E-09 8.81E-07 1.56E-06 0.OOE+00

+--------+---------------------------------------------------------+------------------------------

TEEN  : 9.01E-09  : 1.18E-07  : 1.10E-08 : 1.18E-08 : 1.01E-08  : 1.10E-06  : 2.29E-06  : 0.OOE+00


+---------------+---------------+---------------+------------+------------------------

CHILD  : 1.03E-08  : 3.73E-07  : 1.50E-08 : 1.1lE-08  : 9.42E-09  : 1.26E-06  : 1.86E-06  : 0.OOE+00

+--------+------------------------------+--------------- +-----------------------------------------

INFANT  : 6.17E-09  : 3.15E-07 1.07E-08 : 8.95E-09  : 6.13E-09  : 1.15E-06  : 1.21E-06  : 0.OOE+00

+--------+------------------------------+---------------+--------------- +---------- ---------------

TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2009 (Continued)

SPECIAL LOCATION NO. 5 A Nearest Garden AT 1.30 MILES SW ANNUAL BETA AIR DOSE = 9.41E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 7.26E-05 MILLRADS PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 4.69E-05 : 4.69E-05 : 4.69E-05 : 4.69E-05 : 4.69E-05 : 4.69E-05  : 4.79E-05 . 1.05E-04


------------- +---------------+---------------

GROUND  : 1.30E-04 : 1.30E-04 : 1.30E-04 : 1.30E-04 : 1.30E-04 : 1.30E-04  : 1.30E-04  : 1.53E-04


+----------------+------------------------------ ----------- +---------------+---------------

VEGET  :  :

ADULT 2.25E-06 1.76E-05 4.71E-06 1.24E-06 4.03E-07 5.66E-05 3.36E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.53E-06 : 1.89E-05 : 7.79E-06 : 1.90E-06 : 6.06E-07 : 7.63E-05 : 5.68E-11 0.OOE+00


+--------------- +-------

--- +F------------------------------

CHILD  : 7.17E-06 : 1.25E-05 : 1.90E-05  : 2.94E-06  : 9.53E-07  : 1.46E-04  : 8.12E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  :

ADULT 5.65E-07 4.55E-06 7.09E-08 3.19E-07 5.81E-08 1.53E-06 1.17E-12 0.OOE+00


+-------------+------------------------------

TEEN  : 4.48E-07 : 2.45E-06 : 5.65E-08 : 2.47E-07 : 4.33E-08 : 1.11E-06 : 1.01E-12 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 6.96E-07 : 1.24E-06 : 1.OOE-07 : 2.92E-07 : 5.OOE-08 : 1.67E-06 : 1.12E-12 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :

ADULT  : 3.26E-07 1.23E-06 3.94E-07 4.71E-07 4.16E-07 4.24E-05 4.62E-12 0.OOE+00

-- ----------- +---------------+--------------------------------------------------------------

TEEN  : 5.59E-07 : 1.45E-06  : 6.95E-07  : 8.03E-07  : 7.08E-07  : 6.70E-05 : 8.68E-12  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.11E-06 : 9.65E-07  : 1.64E-06  : 1.27E-06  : 1.12E-06  : 1.33E-04  : 1.26E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 1.73E-06 : 1.80E-06  : 3.04E-06  : 2.53E-06 : 1.76E-06  : 3.22E-04  : 2.50E-11 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : - .  : .  :

ADULT  : 1.31E-07 2.54E-07 5.65E-07 1.97E-07 2.91E-07 5.08E-05 5.54E-13 0.OOE+00


+--------------- -----


+---------------+---------------

TEEN  : 2.23E-07 : 3.18E-07 : 1.04E-06 : 3.47E-07 : 5.16E-07 : 8.05E-05  : 1.04E-12  : 0.OOE+00


+--------------- -----


+---------------+---------------

CHILD  : 4.35E-07 : 2.31E-07 : 2.55E-06 : 5.88E-07 : 8.50E-07 : 1.59E-04  : 1.51E-12  : 0.OOE+00


+--------------- +-------

--- +*------------------------------

INFANT : 7.78E-07 : 3.32E-07 : 4.91E-06 : 1.37E-06 : 1.46E-06 : 3.87E-04  : 3.OOE-12  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL ADULT 2.92E-08 4.13E-07 3.27E-08 3.58E-08 3.OOE-08 4.21E-06 7.66E-06 0.OOE+00


+--------------- -----


+---------------+---------------

TEEN  : 3.90E-08 : 5.01E-07 : 4.63E-08 : 4.80E-08 : 4.11E-08 : 5.25E-06  : 1.12E-05  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 4.42E-08 : 1.35E-06 : 6.33E-08 : 4.44E-08 : 3.83E-08 : 6.OOE-06  : 9.12E-06  : 0.OOE+00


+-------+-------------+---------------+---------------+---------------+---------------+---------------+-----------+

INFANT : 2.56E-08 : 1.12E-06 : 4.47E-08 : 3.47E-08 : 2.49E-08 : 5.50E-06  : 5.91E-06 : 0.OOE+00


+---------------+---------------+--------------- +-------------------- ---------------

TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2009 SPECIAL LOCATION NO. 1 A Site Boundary AT .69 MILES NNW ANNUAL BETA AIR DOSE = 1.31E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 4.66E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+---------------+--------------- ----------

+ ---------------

PLUME  : 2.75E-04 : 2.75E-04 : 2.75E-04 : 2.75E-04 : 2.75E-04 : 2.75E-04 : 2.88E-04 : 7.65E-04


+--------------- +-------

--- +*------------------------------

GROUND  : 3.52E-03 : 3.52E-03 : 3.52E-03 : 3.52E-03 : 3.52E-03 : 3.52E-03 : 3.52E-03 : 4.14E-03


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  : .  :  :

ADULT 5.93E-05 4.84E-04 6.83E-06 4.03E-05 9.11E-06 6.05E-04 8.31E-07 0.OOE+00


+--------------- +-------

--- +*------------------------------

TEEN  : 9.28E-05 : 5.15E-04 : 1.02E-05 : 6.17E-05 : 1.35E-05 : 8.17E-04 : 1.46E-06 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.86E-04 : 3.36E-04 : 2.25E-05 : 9.46E-05 : 2.04E-05 : 1.57E-03 : 2.14E-06 : 0.OOE+00


+---------------+---------------+---------------+---------------+ --------------- +---------------+

MEAT  : .  :

ADULT 1.67E-05 1.30E-04 1.97E-06 1.20E-05 2.51E-06 1.64E-05 5.13E-07 :.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.32E-05 : 7.03E-05  : 1.47E-06  : 9.34E-06  : 1.85E-06  : 1.18E-05 : 4.59E-07  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 2.05E-05 : 3.56E-05  : 2.39E-06  : 1.11E-05  : 2.11E-06  : 1.79E-05 : 5.19E-07 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :

ADULT  : 1.03E-05 : 3.71E-05 5.54E-06 1.70E-05 1.17E-05 4.51E-04 6.49E-08 0.OOE+00 0 TEEN  : 1.77E-05 : 4.32E-05 : 8.81E-06 : 2.86E-05 : 1.91E-05  : 7.14E-04 : 1.27E-07  : 0.OOE+00


+-------+~----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 3.55E-05 : 2.82E-05 : 1.82E-05  : 4.38E-05  : 2.91E-05  : 1.41E-03 : 1.89E-07  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 5.10E-05 : 7.05E-05  : 2.80E-05  : 8.02E-05  : 4.16E-05  : 3.42E-03 : 3.83E-07  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  : .  :  :  :

ADULT  : 2.18E-06 4.87E-06 2.OOE-06 3.66E-06 4.OOE-06 5.41E-04 2.39E-08 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.64E-06 : 5.74E-06 : 3.46E-06 : 6.32E-06 : 6.93E-06 : 8.56E-04  : 4.86E-08  : 0.OOE+00


+--------------- -----


+---------------+---------------

CHILD  : 6.96E-06 : 3.83E-06 : 7.96E-06 : 1.03E-05 : 1.12E-05 : 1.69E-03  : 7.38E-08  : 0.OOE+00


+--------------- +-------

--- ++------------------------------

INFANT : 1.12E-05 : 8.89E-06 : 1.48E-05 : 2.17E-05 : 1.84E-05 : 4.11E-03  : 1.39E-07  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL .  :

ADULT 9.25E-07 1.48E-05 1.83E-07 1.11E-06 4.18E-07 5.02E-05 2.97E-04 0.OOE+00


+-------+-------------+---------------+---------------+---------------+-----------+---------------+---------------+

TEEN  : 1.24E-06 : 1.40E-05  : 2.45E-07  : 1.46E-06  : 5.57E-07  : 6.17E-05  : 4.33E-04  : O.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.40E-06 : 9.83E-06  : 3.15E-07  : 1.28E-06  : 4.97E-07  : 6.85E-05  ; 3.51E-04  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 7.43E-07 : 6.01E-06  : 2.20E-07  : 8.40E-07  : 2:96E-07  : 6.25E-05 : 2.25E-04  : 0.OOE+00


+---------------+--------------- +-------------------- +---------------

TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 2 A Site Boundary AT .67 MILES N ANNUAL BETA AIR DOSE = 1.95E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 6.83E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 4.02E-04 : 4.02E-04 : 4.02E-04 : 4.02E-04 : 4.02E-04 : 4.02E-04 : 4.21E-04 : 1.12E-03 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 6.02E-03 : 6.02E-03 : 6.02E-03 : 6.02E-03 : 6.02E-03 : 6.02E-03 : 6.02E-03 : 7.08E-03

- --- - - ---------------- +------------------------------ ----------------------------- +---------------

VEGET .  :

ADULT 1.01E-04 8.28E-04 1.15E-05 6.89E-05 1.55E-05 1.02E-03 1.42E-06 0.OOE+00

++.  : --------------------------

. +.-- +

TEEN  : 1.59E-04 : 8.80E-04 : 1.72E-05 : 1.05E-04 : 2.30E-05 : 1.38E-03 : 2.49E-06 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 3.18E-04 : 5.75E-04 : 3.77E-05 : 1.62E-04 : 3.47E-05 : 2.64E-03 : 3.64E-06 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  : . . .

ADULT 2.85E-05 2.23E-04 3.36E-06 2.06E-05 4.29E-06 2.75E-05 8.74E-07 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 2.26E-05 : 1.20E-04 : 2.50E-06 : 1.60E-05 : 3.16E-06 : 1.99E-05 : 7.83E-07 : 0.OOE+00

+------------------+------------------------------

+---------------

CHILD  : 3.51E-05 : 6.08E-05 : 4.07E-06 : 1.89E-05 : 3.60E-06 : 3.01E-05 : 8.85E-07 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  : .

ADULT  : 1.76E-05 6.33E-05 9.43E-06 2.90E-05 1.99E-05 7.60E-04 1.10E-07 0.OOE+00

+-------------------------------------+--------------- +-------

--- ++------------------------------

TEEN  : 3.03E-05  : 7.38E-05 : 1.50E-05  : 4.88E-05  : 3.26E-05 : 1.20E-03  : 2.17E-07 : O.OOE+00


+---------------

CHILD  : 6.06E-05 : 4.83E-05 : 3.10E-05 : 7.48E-05 : 4.96E-05 : 2.37E-03 : 3.21E-07 : 0.OOE+00 S+-------+-------------+---------------+---------------+---------------+---------------+-----------+-------- ------- +

INFANT  : 8.70E-05 : 1.20E-04 : 4.75E-05 : 1.37E-04 : 7.08E-05 : 5.77E-03 : 6.52E-07 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  ::  :.:  :

ADULT  : 3.70E-06 8.31E-06 3.36E-06 6.21E-06 6.76E-06 9.12E-04  : 3.97E-08 0.OOE+00

  • -------------------------------------+--------------- -----

+---------------+---------------

TEEN  : 6.18E-06  : 9.81E-06  : 5.81E-06  : 1.07E-05  : 1.17E-05 : 1.44E-03  : 8.05E-08  : 0.OOE+00

-+-+------------------+------------------------------ ----------------------------- +---------------

CHILD  : 1.18E-05  : 6.54E-06  : 1.34E-05  : 1.74E-05  : 1.89E-05 : 2.85E-03 : 1.22E-07  : 0.OOE+00

+-------------------+---------------+---------------+---------------+---------------+---------------+------- 7--------+

INFANT  : 1.89E-05 : 1.52E-05 : 2.50E-05 : 3.68E-05 : 3.10E-05 : 6.92E-03 : 2.30E-07 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------

INHAL  :  : .  : .

ADULT 1.41E-06 2.25E-05 2.76E-07 1.69E-06 6.32E-07 7.57E-05 4.51E-04 0.OOE+00

-- -+------------------+------------------------------ ----------------------------- +---------------

TEEN  : 1.88E-06  : 2.05E-05  : 3.69E-07  : 2.22E-06  : 8.40E-07  : 9.29E-05  : 6.59E-04  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 2.12E-06  : 8.65E-06 : 4.74E-07  : 1.95E-06  : 7.51E-07  : 1.03E-04  : 5.34E-04  : 0.OOE+00 INAT 3-0----------------- --------------

0---------------+.-----0--0----------------1---------------0 INFANT :1.13E-06 :3.57E-06 :3.30E-07 :1.27E-06 :4.46E-07 :9.42E-05 :3.41E-04 :0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 3 A Nearest Resident AT .90 MILES NW ANNUAL BETA AIR DOSE = 3.66E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 1.59E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+---------------+---------------+------------------------------ ---------- ---------------- +

PLUME  : 9.72E-05 : 9.72E-05 : 9.72E-05 : 9.72E-05 : 9.72E-05 : 9.72E-05 : 1.01E-04 : 2.51E-04


+------------------------------+--------------- ------------------------------------------ +

GROUND  : 1.39E-03 : 1.39E-03 : 1.39E-03 : 1.39E-03 : 1.39E-03 : 1.39E-03 : 1.39E-03 : 1.64E-03


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  : .  :  :  :

ADULT 2.35E-05 1.92E-04 4.05E-06 1.60E-05 3.69E-06 2.52E-04 3.33E-07 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

TEEN  : 3.68E-05 : 2.04E-04 : 6.10E-06 : 2.45E-05 : 5.48E-06 : 3.39E-04 : 5.86E-07 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

CHILD  : 7.39E-05 : 1.33E-04 : 1.36E-05 : 3.77E-05 : 8.28E-06 : 6.51E-04 : 8.57E-07 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  :

ADULT 6.60E-06 5.16E-05 7.97E-07 4.77E-06 9.99E-07 6.79E-06 2.03E-07 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

TEEN  : 5.23E-06 : 2.78E-05 : 5.94E-07 : 3.70E-06 : 7.37E-07 : 4.92E-06 : 1.82E-07 : 0.OOE+00

+---------------+--------------------------------------------- +-------------------- ---------------

CHILD  : 8.12E-06  : 1.41E-05  : 9.68E-07  : 4.38E-06  : 8.39E-07 : 7.43E-06 : 2.05E-07  : 0.OOE+00


+-------+-------------+---------------+---------------+---------------+-----------+---------------+---------------+

COW MILK  : . .  :  :

ADULT  : 4.12E-06 1.47E-05 2.29E-06 6.78E-06 4.68E-06 1.88E-04 2.89E-08 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

N) TEEN  : 7.08E-06  : 1.71E-05  : 3.67E-06 : 1.14E-05  : 7.69E-06 : 2.97E-04 : 5.71E-08  : 0.OOE+00


+-------+-----------+---------------+----------- ---- +---------------+---------------+---------------+---------------+

CHILD  : 1.41E-05  : 1.12E-05  : 7.64E-06 : 1.75E-05: 1.17E-05 : 5.86E-04  : 8.49E-08 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 2.03E-05 : 2.79E-05  : 1.18E-05 : 3.22E-05  : 1.68E-05  : 1.42E-03  : 1.70E-07 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :

ADULT  : 9.44E-07 1.95E-06 1.OOE-06 1.57E-06 1.67E-06 2.25E-04 1.93E-08 0.OOE+00


+-+---------------+---------------+--------------- ---------------------------------------- +

TEEN  : 1.53E-06  : 2.31E-06  : 1.73E-06 : 2.72E-06 : 2.90E-06  : 3.56E-04  : 3.95E-08 : 0.OOE+00


+-+------------------------------+--------------- ----------------------------------------- +

CHILD  : 2.87E-06 : 1.54E-06  : 4.02E-06 : 4.45E-06  : 4.69E-06 : 7.03E-04  : 6.03E-08 : 0.OOE+00


+-+---------------+---------------+--------------- ---------------------------------------- +

INFANT  : 4.59E-06  : 3.55E-06  : 7.31E-06 : 9.38E-06  : 7.71E-06 : 1.71E-03  : 1.11E-07 : 0.OOE+00


+---------------+---------------+--------------- ----------------------------------------- +

INHAL . . . . .

ADULT 2.35E-07 3.74E-06 5.28E-08 2.85E-07 1.13E-07 1.33E-05 7.43E-05 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

TEEN  : 3.13E-07 : 3.57E-06 : 7.06E-08 : 3.75E-07 : 1.50E-07 : 1.64E-05 : 1.09E-04 : 0.OOE+00

++' --- --------------- +------------------------------+---------------+---------------+-------------+

CHILD  : 3.55E-07 : 2.88E-06 : 9.10E-08 : 3.30E-07 : 1.35E-07 : 1.82E-05 : 8.79E-05 : 0.OOE+00


+---------------+---------------+--------------- ----------------------------------------- +

INFANT : 1.89E-07 : 1.87E-06 : 6.33E-08 : 2.18E-07 : 8.08E-08 : 1.67E-05 : 5.63E-05 : 0.OOE+00


+---------------+---------------+--------------- ----------------------------------------- +

TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 7.90E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 6.54E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+------------------------------+------------------------------ --------------------------- +

PLUME  : 4.26E-05 : 4.26E-05 : 4.26E-05 : 4.26E-05 : 4.26E-05 : 4.26E-05 : 4.34E-05 : 9.31E-05


+------------------------------+--------------- ------------------------------------------ +

GROUND  : 7.17E-05 : 7.17E-05 : 7.17E-05 : 7.17E-05 : 7.17E-05 : 7.17E-05 : 7.17E-05 : 8.44E-05


. +-.+--------------------------------+---------------+------- ------------------------------

VEGET  :  :  :  :  :

ADULT 1.24E-06 9.92E-06 7.01E-07 8.56E-07 2.20E-07 1.73E-05 1.86E-08 0.OOE+00


.-- + ------------------------------- +--------------- -------- ------------------------------- +

TEEN  : 1.93E-06 : 1.06E-05 : 1.07E-06 : 1.31E-06 : 3.28E-07 : 2.34E-05 : 3.29E-08 : 0.OOE+00


. +-.++------------------------------+--------------- ------- ------------------------------- +

CHILD  : 3.87E-06 : 6.90E-06 : 2.42E-06 : 2.02E-06 : 5.OOE-07 : 4.48E-05 : 4.83E-08 : 0.OOE+00


+------------------------------+--------------- ------------------------------------------ +

MEAT  :  :  :  : .

ADULT 3.41E-07 2.66E-06 4.74E-08 2.47E-07 5.32E-08 4.67E-07 1.04E-08 0.OOE+00


+---------------+---------------+---------------- ++------- ------------------------------

TEEN  : 2.70E-07 : 1.43E-06 : 3.55E-08 : 1.92E-07 : 3.94E-08 : 3.38E-07 : 9.32E-09 : 0.OOE+00

+-+----------------------------- +------------------------------------------------------------------+

CHILD  : 4.19E-07  : 7.24E-07  : 5.85E-08 : 2.28E-07  : 4.49E-08 : 5.10E-07  : 1.05E-08  : 0.OOE+00


++---------------+---------------+--------------- +------- ------------------------------

COW MILK :  :  :  :  :

ADULT  : 2.27E-07 7.64E-07 1.56E-07 3.74E-07 2.65E-07 1.30E-05 2.66E-09 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.85E-07  : 8.91E-07  : 2.54E-07 : 6.33E-07  : 4.38E-07 : 2.05E-05  : 5.37E-09  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 7.60E-07  : 5.84E-07  : 5.47E-07 : 9.79E-07  : 6.73E-07 : 4.05E-05  : 8.11E-09  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 1.10E-06  : 1.46E-06  : 8.69E-07 : 1.82E-06  : 9.82E-07 : 9.85E-05 : 1.55E-08  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :: .

ADULT  : 7.77E-08 1.10E-07 1.29E-07 1.26E-07 1.18E-07 1.55E-05 4.58E-09 0.OOE+00


++---------------+---------------+---------------+--+------- ------------------------------

TEEN  : 1.12E-07  : 1.31E-07  : 2.24E-07 : 2.19E-07 : 2.07E-07 : 2.46E-05 : 9.44E-09  : 0.OOE+00


++---------------+---------------+---------------+--+------- ------------------------------

CHILD  : 1.89E-07  : 8.92E-08  : 5.23E-07 : 3.66E-07  : 3.37E-07 : 4.86E-05  : 1.45E-08  : 0.OOE+00


++---------------+---------------+------------------------------ ---------- --------------- +

INFANT  : 2.99E-07 : 1.94E-07  : 9.03E-07  : 7.68E-07  : 5.59E-07 : 1.18E-04  : 2.63E-08 0.OOE+00


++---------------+---------------+---------------+--+------- ------------------------------

INHAL .  :  : -

ADULT 3.27E-08 4.97E-07 1.39E-08 4.23E-08 2.20E-08 2.28E-06 9.33E-06 0.OOE+00


+---------------+---------------+---------------+---+------- ------------------------------

TEEN  : 4.36E-08  : 5.18E-07  : 1.86E-08  : 5.61E-08  : 2.97E-08 : 2.84E-06  : 1.36E-05  : 0.OOE+00


+---------------+---------------+---------------+---+------- ------------------------------

CHILD  : 4.94E-08  : 7.44E-07  : 2.42E-08 : 5.02E-08  : 2.70E-08  : 3.21E-06  : 1.11E-05  : O.OOE+00


+---------------+---------------+---------------+---+------- ------------------------------

INFANT : 2.73E-08 : 5.66E-07 : 1.65E-08 : 3.54E-08 : 1.67E-08  : 2.93E-06  : 7.10E-06  : 0.OOE+00


+---------------+---------------+---------------+---+------- ------------------------------

TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 5 A Nearest Garden AT 1.30 MILES SW ANNUAL BETA AIR DOSE = 1.22E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 9.95E-05 MILLRADS PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

+----------------+---------------+------------------------------ +--------- ---------------

PLUME  : 6.47E-05 : 6.47E-05 : 6.47E-05 : 6.47E-05  : 6.47E-05  : 6.47E-05  : 6.60E-05  : 1.42E-04

...-.. . + -+------------------------------+--------------- -------------------------- +---------------

GROUND  : 3.12E-04 : 3.12E-04 : 3.12E-04 : 3.12E-04 : 3.12E-04 : 3.12E-04 : 3.12E-04 : 3.68E-04 S+-------+------------+---------------+---------------+---------------+---------------+-------------+---------------+

VEGET  :  :

ADULT 5.43E-06 4.32E-05 3.44E-06 3.75E-06 9.83E-07 7.93E-05 8.22E-08 0.OOE+00

- ++---------------------

+ ---------------------------- ----------------------------- +---------------

TEEN  : 8.45E-06  : 4.60E-05 : 5.25E-06  : 5.75E-06  : 1.47E-06  : 1.07E-04  : 1.46E-07  : 0.OOE+00

...-.. . + -+--------------------------------------------- --------------------------- +---------------

CHILD  : 1.69E-05  : 3.01E-05 : 1.19E-05 : 8.86E-06  : 2.24E-06  : 2.05E-04  : 2.14E-07 : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

NEAT  :  :  :  :  :

ADULT 1.49E-06 1.16E-05 2.12E-07 1.08E-06 2.33E-07 2.14E-06 4.53E-08 0.OOE+00

- + -------------------- +------------------------------ ------------- +---------------+---------------

TEEN  : 1.18E-06  : 6.23E-06 : 1.59E-07 : 8.38E-07  : 1.73E-07  : 1.55E-06  : 4.06E-08 : 0.OOE+00

- + -------------------- +------------------------------ ----------------------------- +---------------

CHILD  : 1.82E-06 : 3.15E-06 : 2.62E-07 : 9.93E-07 : 1.97E-07 : 2.34E-06 : 4.60E-08 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK : .  :  :

ADULT  : 1.OOE-06 3.33E-06 7.10E-07 1.65E-06 1.18E-06 5.93E-05 1.25E-08 0.OOE+00

+--++-++--------------------------------------------+---------------+---------------+---------------

TEEN  : 1.69E-06  : 3.89E-06 : 1.16E-06 : 2.80E-06  : 1.95E-06 : 9.38E-05  : 2.53E-08 : 0.OOE+00

++---------------------------+------------------------------ ------------ +-----------+-------------

CHILD  : 3.33E-06  : 2.55E-06 : 2.51E-06  : 4.33E-06  : 2.99E-06  : 1.86E-04  : 3.83E-08 : 0.OOE+00

- + -------------------- +------------------------------ ------------- +---------------+---------------

INFANT : 4.82E-06 : 6.38E-06 : 4.OOE-06 : 8.05E-06 : 4.38E-06 : 4.51E-04 : 7.30E-08 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  ::"

ADULT 3.62E-07 4.84E-07 6.23E-07 5.84E-07 5.43E-07 7.12E-05 2.28E-08 0.OOE+00

- + -------------------- +--------------------------------------------+------------------------------

TEEN  : 5.17E-07  : 5.81E-07  : 1.08E-06  : 1.02E-06  : 9.49E-07  : 1.13E-04  : 4.70E-08  : 0.OOE+00

- + -------------------- +--------------------------------------------+------------------------------

CHILD  : 8.56E-07  : 3.97E-07  : 2.53E-06  : 1.70E-06  : 1.55E-06 : 2.23E-04  : 7.22E-08  : O.OOE+00

- - S+-- ------------------------------------------------------------- +------------------------------

INFANT  : 1.35E-06 : 8.56E-07 : 4.36E-06 : 3.58E-06 : 2.57E-06 : 5.41E-04 : 1.31E-07 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  :  : .

ADULT 5.52E-08 8.51E-07 2.23E-08 7.09E-08 3.55E-08 3.66E-06 1.60E-05 0.OOE+00

- ++------------------+--------------------------------------------+------------------------------

TEEN  : 7.37E-08  : 8.91E-07  : 2.97E-08  : 9.40E-08  : 4.78E-08  : 4.54E-06  : 2.34E-05 : 0.OOE+00


+------------------------------

CHILD  : 8.36E-08  : 1.33E-06  : 3.86E-08  : 8.40E-08  : 4.34E-08 : 5.14E-06  : 1.90E-05 : 0.OOE+00 INAT 9-0-------------------------------0---------------5. 0 ---- .-- 0  :---------------2---------------0 INFANT :4.59E-08 :1.02E-06 :2.63E-08 :5.87E-08 :2.68E-08 :4.69E-06 :1.22E-05 :0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TABLE 6. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2009 SPECIAL LOCATION NO. 1 A Site Boundary AT .67 MILES N ANNUAL BETA AIR DOSE = 2.49E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 9.04E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 5.36E-04 : 5.36E-04 : 5.36E-04 : 5.36E-04 : 5.36E-04  : 5.36E-04  : 5.60E-04 : 1.48E-03

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 7.17E-03 : 7.17E-03 : 7.17E-03 : 7.17E-03 : 7.17E-03  : 7.17E-03  : 7.17E-03 : 8.43E-03

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :  :  :

ADULT 1.22E-04 9.82E-04 7.23E-05 7.90E-05 1.96E-05 1.71E-03 1.30E-06 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 1.90E-04  : 1.05E-03  : 1.18E-04  : 1.21E-04  : 2.93E-05  : 2.31E-03  : 2.29E-06 : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 3.83E-04  : 6.85E-04  : 2.82E-04  : 1.86E-04  : 4.47E-05  : 4.42E-03  : 3.34E-06 : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  :  : .  :  :  :

ADULT 3.33E-05 2.62E-04 4.OOE-06 2.29E-05 4.67E-06 4.62E-05 7.97E-07 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 2.64E-05  : 1.41E-04  : 3.02E-06  : 1.77E-05 : 3.45E-06 : 3.34E-05  : 7.13E-07  : 0.OOE+00


+----------------------------------------------------------+-----------------------------

CHILD  : 4.09E-05 : 7.14E-05  : 5.02E-06  : 2.10E-05  : 3.94E-06 : 5.05E-05  : 8.06E-07 : 0.OOE+00


+---------------------------------------------+----------------------------

COW MILK :  :  :  :  :  :

ADULT  : 2.03E-05 7.37E-05 1.38E-05 3.27E-05 2.37E-05 1.28E-03 1.07E-07 0.OOE+00 U.------------+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 3.50E-05  : 8.61E-05  : 2.29E-05 : 5.52E-05  : 3.92E-05 : 2.02E-03 : 2.11E-07  : O.OOE+00


+--------------------------------------------------------------------------

CHILD  : 6.99E-05 : 5.65E-05 : 5.01E-05 : 8.51E-05 : 6.03E-05 : 3.99E-03 : 3.14E-07  : O.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 1.02E-04 : 1.33E-04 : 8.37E-05 : 1.59E-04 : 8.85E-05 : 9.71E-03 : 6.32E-07  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :

ADULT  : 5.27E-06 1.09E-05 1.07E-05 8.53E-06 1.02E-05 1.53E-03 5.62E-08 O.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 8.75E-06 : 1.31E-05  : 1.92E-05 : 1.48E-05 : 1.79E-05 O 2.43E-03 : 1.15E-07  : 0.OOE+00


+--------------------------------------------------------------------------

CHILD  : 1.67E-05 : 8.98E-06  : 4.63E-05 : 2.45E-05  : 2.91E-05 : 4.79E-03  : 1.75E-07  : O.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 2.78E-05 : 1.82E-05  : 8.81E-05  : 5.33E-05 : 4.86E-05  : 1.16E-02  : 3.25E-07  : 0.OOE+00

- +------------------+ --------------- +---------------+---------------+---------------+---------------+

INHAL  : .  :  :  :  :

ADULT 1.78E-06 2.78E-05 7.78E-07 2.13E-06 1.06E-06 1.42E-04 5.50E-04 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 2.38E-06 : 2.77E-05 : 1.08E-06 : 2.82E-06 : 1.43E-06  : 1.75E-04  : 8.03E-04  : 0.OOE+00

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 2.68E-06 : 3.35E-05 : 1.45E-06 : 2.51E-06 : 1.30E-06  : 1.98E-04  : 6.51E-04  : 0.OOE+00

- +-------+-------------+---------------+---------------+---------------+---------------+-----------+---------------+

INFANT : 1.45E-06 : 2.46E-05 : 1.01E-06 : 1.71E-06 : 8.04E-07  : 1.81E-04  : 4.18E-04  : O.OOE+00

- +- - -*+------------------------------------------------------------------ --------- +---------------

TABLE 6. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 2 A Site Boundary AT .60 MILES NNE ANNUAL BETA AIR DOSE = 1.56E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 5.55E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

+-......-+--------------------------------+--------------- +------- ------------------------------

PLUNE  : 3.27E-04 : 3.27E-04  : 3.27E-04  : 3.27E-04  : 3.27E-04  : 3.27E-04  : 3.43E-04  : 9.12E-04

......- *--------------------------------+--------------- +-------- ---------------- +---------------+

GROUND  : 4.49E-03 : 4.49E-03 : 4.49E-03 : 4.49E-03 : 4.49E-03 : 4.49E-03 : 4.49E-03 : 5.28E-03

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  : .  :  :

ADULT 7.61E-05 6.15E-04 4.40E-05 4.94E-05 1.22E-05 1.06E-03 8.11E-07 0.OOE+00 S--*----------------------------------+---------------+-- ------------------------ +---------------+

TEEN  : 1.19E-04 : 6.55E-04 : 7.18E-05 : 7.56E-05  : 1.82E-05  : 1.43E-03  : 1.43E-06 : 0.OOE+00

- -- ------------------------------- +---------------+--

+-- ----------------------- +---------------+

CHILD  : 2.40E-04 : 4.29E-04 : 1.73E-04 : 1.16E-04 : 2.78E-05 : 2.75E-03 :.2.09E-06 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  :  :  :  : .  :

ADULT 2.08E-05 1.64E-04 2.49E-06 1.43E-05 2.92E-06 2.87E-05 4.99E-07 0.OOE+00 S--. +-----------------------+---------------+

+---------------

TEEN  : 1.65E-05 : 8.84E-05 : 1.88E-06 : 1.11E-05 : 2.16E-06 : 2.08E-05 : 4.47E-07 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 2.57E-05 : 4.47E-05 : 3.13E-06 : 1.31E-05 : 2.46E-06 : 3.13E-05 : 5.05E-07 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  : -  :

, ADULT 1.27E-05 4.62E-05 8.58E-06 2.04E-05 1.48E-05 7.93E-04 6.44E-08 0.OOE+00 w - +----------------------------------------------------------------------------------

0N TEEN 2.19E-05 : 5.39E-05  : 1.42E-05 : 3.45E-05 : 2.45E-05  : 1.25E-03  : 1.26E-07  : 0.OOE+00


*----------------------------------------------------------------------------+---------------+

CHILD  : 4.37E-05 : 3.54E-05  : 3.10E-05 : 5.32E-05 : 3.76E-05  : 2.48E-03 : 1.88E-07  : 0.OOE+00 S+ ---------------------------- +---------------+

+------------------+------------------------------

INFANT  : 6.38E-05 : 8.34E-05  : 5.18E-05 : 9.90E-05  : 5.52E-05 : 6.02E-03  : 3.80E-07  : 0.OOE+00

- +*+------------------------------------------------ +--------------------------------------------

GOATMILK  :  :

ADULT  : 3.23E-06 6.80E-06 6.50E-06 5.24E-06 6.33E-06 9.52E-04 2.67E-08 0.OOE+00 S+------------------+---------------+--------------- ++------- ------------------------------

TEEN  : 5.41E-06  : 8.18E-06 : 1.17E-05 : 9.09E-06 : 1.11E-05 : 1.51E-03 : 5.43E-08 : O.OOE+00 S---+----------------------------------------------------------------------------+---------------+

CHILD  : 1.04E-05 : 5.60E-06 : 2.82E-05 : 1.50E-05 : 1.80E-05 : 2.97E-03 : 8.26E-08 : 0.OOE+00 S+----------------------------------------------------------------------+------------------------+

INFANT  : 1.73E-05 : 1.14E-05 : 5.39E-05 : 3.27E-05 : 3.01E-05 : 7.23E-03 : 1.55E-07 : 0.OOE+00 S-*-------------------+----------------------------------------------------------+---------------+

INHAL "  :  : "  :  :

ADULT 1.15E-06 1.80E-05 4.99E-07 1.37E-06 6.77E-07 9.04E-05 3.56E-04 O.OOE+00

- ++------------------+----------------------------------------------------------+---------------+

TEEN  : 1.53E-06  : 1.79E-05 : 6.93E-07  : 1.82E-06  : 9.12E-07  : 1.12E-04  : 5.20E-04  : 0.OOE+00

--- ------------------------------------------ 7 ---------------------- ----------- -+---------------+

CHILD  : 1.73E-06  : 2.15E-05  : 9.29E-07  : 1.61E-06  : 8.30E-07  : 1.26E-04  : 4.21E-04  : 0.OOE+00

++------- ------------------- +---------------+--------------- +-------------------- +---------------+

INFANT  : 9.38E-07  : 1.58E-05 : 6.50E-07  : 1.10E-06  : 5.13E-07  : 1.15E-04  : 2.71E-04  : 0.OOE+00

-+--*-----------------+----------------------------------------------------------+---------------+

TABLE 6. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 3 A Nearest Resident AT .90 MILES NW ANNUAL BETA AIR DOSE = 5.80E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 3.38E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


*---------------------------------+--------------- - -----------------------

+ +---------------+

PLUME  : 2.13E-04 : 2.13E-04 : 2.13E-04 : 2.13E-04 : 2.13E-04 : 2.13E-04 : 2.19E-04 : 5.06E-04  :

-+--------------------+---------------+--------------- - + ------------------------------ ++-------

GROUND  : 2.57E-03 : 2.57E-03 : 2.57E-03 : 2.57E-03 : 2.57E-03 : 2.57E-03 : 2.57E-03 : 3.02E-03  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET . . . .

ADULT 4.40E-05 3.53E-04 3.29E-05 2.87E-05 7.43E-06 6.70E-04 4.86E-07 :0.OOE+00

--- ---------------- +---------------+

+------------------+---------------+---------------+---------

TEEN  : 6.87E-05 : 3.76E-04  : 5.29E-05  : 4.39E-05  : 1.11E-05  : 9.04E-04  : 8.58E-07  : 0.OOE+00  :

--- *------------------+---------------+---------------+-----+------- ------------------------------

CHILD  : 1.38E-04 : 2.46E-04  : 1.26E-04  : 6.77E-05  : 1.70E-05  : 1.73E-03 : 1.26E-06  : 0.OOE+00 :

+--------------------+---------------+---------------+---------------+---------------+---------------+---------------+

HEAT - .

ADULT 1.19E-05 9.39E-05 1.52E-06 8.22E-06 1.70E-06 1.81E-05 2.85E-07 0.OOE+00


*+--------------------------------+--------------- --------------------------- +---------------+

TEEN  : 9.46E-06 : 5.06E-05  : 1.15E-06 : 6.38E-06  : 1.26E-06  : 1.31E-05 : 2.56E-07  : 0.OOE+00 :


*-----------------+---------------+--------------- --------------------------- +---------------+

CHILD  : 1.47E-05 : 2.56E-05 : 1.92E-06 : 7.55E-06 : 1.43E-06 : 1.98E-05 : 2.89E-07 : 0.OOE+00 :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :

ADULT  : 7.49E-06 2.65E-05 5.48E-06 1.20E-05 8.82E-06 5.01E-04 5.41E-08 0.OOE+00


*-----------------+----------------------------------------------------------+---------------+

TEEN  : 1.28E-05 : 3.10E-05  : 9.13E-06  : 2.04E-05 : 1.46E-05  : 7.93E-04 : 1.08E-07  : 0.OOE+00 :


*-----------------+----------------------------------------------------------+---------------+

CHILD  : 2.55E-05  : 2.04E-05  : 2.01E-05  : 3.15E-05  : 2.25E-05  : 1.57E-03 : 1.62E-07  : 0.OOE+00 :


++-------- +-------------------- --------------- +

INFANT  : 3.72E-05  : 4.80E-05  : 3.37E-05 : 5.89E-05 : 3.33E-05  : 3.81E-03 : 3.16E-07  : 0.OOE+00 :


+----------------------------------------------------

+

GOATMILK  :  :

ADULT  : 2.27E-06 4.03E-06 4.89E-06 3.65E-06 4.09E-06 6.01E-04 6.77E-08 0.OOE+00

--- *+----------------------------------------------------------------------------+---------------+

TEEN  : 3.58E-06  : 4.87E-06  : 8.75E-06 : 6.35E-06  : 7.16E-06  : 9.51E-04  : 1.39E-07  : 0.OOE+00  :

-- --- +---------------------------------------------------------------------------+---------------+

CHILD  : 6.54E-06  : 3.36E-06  : 2.10E-05 : 1.06E-05 : 1.17E-05  : 1.88E-03 : 2.14E-07  : 0.OOE+00:

+ ++------------------+--------------------------------------------- ------------- +---------------+

INFANT : 1.08E-05  : 6.67E-06  : 3.89E-05 : 2.29E-05 : 1.95E-05  : 4.57E-03 : 3.90E-07 : 0.OOE+00  :

+---*+---------------------------------------------------------------------------+---------------+

INHAL  :  :  :  :  :  :

ADULT 3.25E-07 5.02E-06 1.59E-07 3.98E-07 2.10E-07 2.66E-05 9.74E-05 0.OOE+00

+---*+---------------------------------------------------------------------------+---------------+

TEEN  : 4.34E-07  : 5.16E-06  : 2.20E-07 : 5.27E-07  : 2.84E-07  : 3.30E-05 : 1.42E-04  : 0.OOE+00  :

+---*+---------------------------------------------------------------------------+---------------+

CHILD  : 4.91E-07  : 7.39E-06  : 2.95E-07 : 4.71E-07  : 2.59E-07  : 3.73E-05 : 1.15E-04  : 0.OOE+00  :

+++-----------------------+------------------------------------------------------ +---------------+

INFANT : 2.69E-07  : 5.63E-06  : 2.05E-07 : 3.28E-07  : 1.62E-07  : 3.41E-05 : 7.42E-05 : 0.OOE+00  :

-+--*+---------------------------------------------------------------------------+---------------+

TABLE 6. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 9.84E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 7.38E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER - KIDNEY THYROID LUNG - SKIN

-.. ------------------------------------------------------------------------ . .+------------------- +

PLUME  : 4.78E-05 : 4.78E-05  : 4.78E-05 : 4.78E-05  : 4.78E-05  : 4.78E-05  : 4.88E-05  : 1.09E-04 S+4+------------------+-----------------------------+------------------------------+-------------+

GROUND  : 9.56E-05 : 9.56E-05 : 9.56E-05 : 9.56E-05 : 9.56E-05 : 9.56E-05 : 9.56E-05 : 1.12E-04 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :

ADULT 1.67E-06 1.32E-05 1.77E-06 1.10E-06 3.06E-07 2.92E-05 1.96E-08 0.00E+00

+ ----------------------------

++---------------------------------+--------------- +---------------+

TEEN  : 2.60E-06  : 1.41E-05  : 2.80E-06 : 1.68E-06  : 4.57E-07  : 3.93E-05  : 3.48E-08  : 0.00E+00

+---*+---------------------------------------------------------------------------+---------------+

CHILD  : 5.22E-06 : 9.22E-06 : 6.60E-06 : 2.60E-06 : 7.04E-07 : 7.54E-05 : 5.11E-08 : 0.00E+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT . . . . .

ADULT 4.46E-07 3.49E-06 6.36E-08 3.08E-07 6.50E-08 7.86E-07 1.06E-08 0.00E+00 S+ +-------------------------------------------- +----------------------------------------------

TEEN  : 3.53E-07 : 1.88E-06  : 4.83E-08 : 2.39E-07  : 4.81E-08  : 5.70E-07  : 9.50E-09  : 0.OOE+00 S+ +4+----------------+--------------------------------------------------------------------------

CHILD  : 5.47E-07 : 9.51E-07 : 8.11E-08 : 2.83E-07 : 5.51E-08 : 8.60E-07 : 1.07E-08 : 0.00E+00

-+-------+/----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  : .

ADULT  : 2.94E-07 9.95E-07 2.44E-07 4.73E-07 3.52E-07 2.18E-05 3.22E-09 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 4.97E-07 : 1.16E-06 : 4.09E-07 : 8.02E-07 : 5.86E-07 : 3.46E-05 : 6.52E-09 : 0.OOE+00


+---------------+---------------+---------------+---------------+ --------------- +---------------+

CHILD  : 9.79E-07 : 7.65E-07 : 9.12E-07 : 1.25E-06 : 9.08E-07 : 6.83E-05 : 9.88E-09 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 1.44E-06 : 1.81E-06 : 1.53E-06 : 2.35E-06 : 1.35E-06 : 1.66E-04 : 1.87E-08 : 0.00E+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : . . .

ADULT  : 1.14E-07 1.60E-07 2.64E-07 1.81E-07 1.84E-07 2.62E-05 6.20E-09 0.OOE+00

+---*+-- --------------------------------------------- ---------------------------- +---------------+

TEEN  : 1.67E-07  : 1.94E-07  : 4.69E-07 : 3.16E-07  : 3.23E-07  : 4.15E-05  : 1.28E-08  : 0.OOE+00

-+--*-----------------+---------------+----------------------------------------------------------+

CHILD  : 2.85E-07  : 1.35E-07  : 1.12E-06  : 5.32E-07  : 5.29E-07 : 8.20E-05 : 1.96E-08  : 0.OOE+00

+---*-----------------+---------------+--------------- ------------------------------------------- +

INFANT  : 4.65E-07 : 2.60E-07  : 2.02E-06  : 1.14E-06  : 8.87E-07  : 1.99E-04  : 3.57E-08  : 0.00E+00

-+--*----------------+---------------+---------------+-------------------------------------------+

INHAL . . . .

ADULT 3.47E-08 5.29E-07 2.36E-08 4.46E-08 2.82E-08 3.36E-06 9.63E-06 0.00E+00

+---*-- ---------------------------------------------- +-------------------------------------------+

TEEN  : 4.61E-08  : 5.65E-07  : 3.22E-08  : 5.93E-08  : 3.82E-08  : 4.19E-06 : 1.41E-05  : 0.OOE+00

--- *----------------------------------+--------------- - - -------------------------------------

+ +

CHILD  : 5.22E-08  : 8.78E-07  : 4.27E-08  : 5.36E-08  : 3.50E-08  : 4.79E-06 : 1.14E-05  : 0.00E+00

+---*+----------------------------------------------- +---------------------------+---------------+

INFANT  : 2.91E-08 : 6.75E-07 : 2.90E-08 : 3.89E-08 : 2.21E-08 : 4.37E-06 : 7.35E-06 : 0.OOE+00

-+--*----------------+---------------+---------------+-------------------------------------------+

TABLE 6. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 5 A Nearest Garden AT 1.30 MILES SW ANNUAL BETA AIR DOSE = 2.33E-04 MILLRADS ANNUAL GAMMA AIR DOSE = .1.87E-04 MILLRADS PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


*---------------------------------+---------------+--------------- --------------------------- +

PLUME  : 1.21E-04  : 1.21E-04  : 1.21E-04  : 1.21E-04  : 1.21E-04  : 1.21E-04  : 1.23E-04  : 2.68E-04


*4--------------------------------+--------------- +------------------------------------------+

GROUND  : 4.81E-04 : 4.81E-04 : 4.81E-04 : 4.81E-04 : 4.81E-04 : 4.81E-04 : 4.81E-04 : 5.65E-04

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :

ADULT 8.30E-06 6.61E-05 7.45E-06 5.44E-06 1.46E-06 1.36E-04 9.45E-08 0.OOE+00

--- +---4-+-------------------------


+-------------------------------------------+

TEEN  : 1.29E-05  : 7.05E-05 : 1.19E-05  : 8.33E-06  : 2.18E-06  : 1.83E-04  : 1.67E-07  : 0.OOE+00


*---------------------------------+--------------- +------------------------------------------+

CHILD  : 2.60E-05  : 4.62E-05 : 2.81E-05  : 1.28E-05  : 3.35E-06  : 3.50E-04  : 2.45E-07  : 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT .  :  : . .

ADULT 2.24E-06 1.76E-05 3.01E-07 1.54E-06 3.22E-07 3.66E-06 5.33E-08 0.OOE+00


*---------------------------------+--------------- +------------------------------------------+

TEEN  : 1.77E-06  : 9.45E-06 : 2.28E-07  : 1.20E-06  : 2.38E-07  : 2.65E-06 : 4.78E-08  : 0.OOE+00 4---*---------------------------------+--------------- +------------------------------------------+

CHILD  : 2.75E-06 : 4.78E-06 : 3.82E-07 : 1.42E-06 : 2.72E-07 : 4.OOE-06 : 5.41E-08 : 0.OOE+00

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  : .  :  : .

ADULT  : 1.44E-06 4.98E-06 1.12E-06 2.31E-06 1.71E-06 1.01E-04 1.30E-08 0.OOE+00

  • --- +------- --------------------------------------------

- +

TEEN  : 2.44E-06  : 5.82E-06 : 1.87E-06  : 3.92E-06  : 2.84E-06  : 1.60E-04  : 2.62E-08  : 0.OOE+00


*---------------------------------+--------------- +------------------------------------------+

CHILD  : 4.84E-06 : 3.83E-06 : 4.15E-06 : 6.07E-06 4.38E-06 : 3.17E-04 : 3.95E-08 : 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 7.08E-06 : 9.03E-06 : 6.96E-06 : 1.14E-05 : 6.50E-06 : 7.71E-04 : 7.57E-08 : 0.OOE+00

-+-------+-------------+---------------+---------------+---------------+---------------+---- :-------+---------------+

GOATMILK  :  :  : .  :

ADULT  : 4.96E-07 7.77E-07 1.11E-06 7.90E-07 8.42E-07 1.22E-04 2.14E-08 0.OOE+00 4---*---------------------------------+--------------- +------------------------------------------+

TEEN  : 7.51E-07  : 9.41E-07  : 1.98E-06  : 1.38E-06  : 1.48E-06  : 1.93E-04  : 4.42E-08  : 0.OOE+00

+ - +-*--------------------------------+--------------- +---------------------------+---------------+

CHILD  : 1.32E-06  : 6.53E-07  : 4.73E-06  : 2.31E-06  : 2.41E-06  : 3.81E-04  : 6.78E-08  : 0.OOE+00

--- *----------------------------------+--------------- +------------------------------------------+

INFANT : 2.17E-06  : 1.28E-06 : 8.64E-06  : 4.97E-06  : 4.04E-06  : 9.25E-04  : 1.23E-07  : O.OOE+00

- - +----------------------------------+--------------- +---------------------------+---------------+

INHAL . .  : . .

ADULT 9.49E-08 1.43E-06 5.52E-08 1.20E-07 6.98E-08 8.11E-06 2.69E-05 0.OOE+00

--- *----------------------------------+--------------- +------------------------------------------+

TEEN  : 1.27E-07  : 1.51E-06  : 7.58E-08  : 1.60E-07  : 9.45E-08  : 1.01E-05  : 3.93E-05  : O.OOE+00


*---------------------------------+--------------- +------------------------------------------+

CHILD  : 1.44E707  : 2.42E-06 : 1.01E-07  : 1.44E-07  : 8.66E-08  : 1.14E-05  : 3.19E-05  : 0.OOE+00

--- *----------------------------------+--------------- +------------------------------------------+

INFANT : 7.99E-08  : 1.88E-06 : 7.01E-08 . 1.04E-07  : 5.44E-08  : 1.05E-05  : 2.05E-05 : 0.OOE+00


*---------------------------------+--------------- +------------------------------------------+

TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-DECEMBER 2009 SPECIAL LOCATION NO. 1 A Site Boundary AT .67 MILES N ANNUAL BETA AIR DOSE = 3.74E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.99E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+---------------+---------------+--------------- ---------

+ +---------------

PLUME  : 1.26E-03 : 1.26E-03 : 1.26E-03 : 1.26E-03 : 1.26E-03 : 1.26E-03 : 1.29E-03 : 3.26E-03


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 1.02E-02 : 1.02E-02 : 1.02E-02 : 1.02E-02 : 1.02E-02 : 1.02E-02 : 1.02E-02 : 1.20E-02


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET ADULT 1.91E-04 1.44E-03 4.44E-04 1.23E-04 5.98E-05 9.44E-03 1.26E-06 0.OOE+00


+----------------------------------------- -+---------------+---------------

TEEN  : 2.98E-04 : 1.54E-03 : 7.33E-04 : 1.88E-04 : 9.04E-05 : 1.27E-02 : 2.22E-06 : 0.OOE+00


+----------------------------------------- -+---------------+---------------

CHILD  : 6.03E-04 : 1.02E-03 : 1.79E-03 : 2.94E-04 : 1.43E-04 : 2.44E-02 : 3.24E-06 : 0.OOE+00

-- ---------------- +---------------+------------------------------ +---------------+---------------

MEAT  :  :  :  :  :

ADULT 4.60E-05 3.68E-04 7.78E-06 2.88E-05 5.62E-06 2.55E-04 7.70E-07 0.OOE+00


+----------------------------------------- -+---------------+---------------

TEEN  : 3.65E-05 : 1.98E-04 : 6.22E-06 : 2.24E-05 : 4.24E-06 : 1.85E-04 : 6.90E-07 : 0.OOE+00


+----------------------------------------------------------+---------------

CHILD  : 5.66E-05 : 1.OOE-04 : 1.11E-05 : 2.66E-05 : 4.95E-06 : 2.79E-04 : 7.79E-07 : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  :

ADULT  : 3.32E-05 1.04E-04 4.25E-05 5.07E-05 5.34E-05 7.05E-03 1.07E-07 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

C TEEN  : 5.67E-05  : 1.22E-04 : 7.55E-05  : 8.72E-05  : 9.23E-05  : 1.11E-02  : 2.10E-07 :0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.11E-04  : 8.18E-05 : 1.79E-04  : 1.41E-04  : 1.49E-04  : 2.20E-02  : 3.12E-07  :.0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 1.79E-04  : 1.53E-04 : 3.40E-04  : 2.95E-04  : 2.43E-04  : 5.35E-02  : 6.27E-07  : 0.OOE+00


+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :

ADULT  : 1.87E-05 2.48E-05 6.03E-05 2.98E-05 4.65E-05 8.46E-03 6.31E-08 O.OOE+00


+ --------------- +---------------------------------------------------------+---------------

TEEN  : 3.13E-05 : 3.15E-05 : 1.10E-04  : 5.26E-05  : 8.25E-05  : 1.34E-02  : 1.29E-07  : 0.OOE+00


+ --------------- +---------------------------------------------------------+---------------

CHILD  : 5.95E-05  : 2.32E-05  : 2.71E-04  : 9.03E-05  : 1.37E-04  : 2.64E-02  : 1.97E-07  : 0.OOE+00


+ --------------- +---------------------------------------------------------+---------------

INFANT  : 1.09E-04  : 3.17E-05 : 5.27E-04  : 2.14E-04  : 2.36E-04  : 6.42E-02  : 3.64E-07  : O.OOE+00


+ --------------- +---------------------------------------------------------+---------------

INHAL  : .  : .  :

ADULT 2.88E-06 3.76E-05 3.51E-06 3.70E-06 3.51E-06 5.99E-04 6.80E-04 0.OOE+00


+ --------------- +---------------------------------------------------------+---------------

TEEN  : 3.81E-06 : 5.11E-05 : 4.97E-06 : 4.97E-06 : 4.80E-06 : 7.39E-04 : 9.99E-04 : 0.OOE+00

+-------------+---------------+------------------  :- - ----------- +---- ------------------------------

CHILD  : 4.24E-06 : 1.81E-04 : 6.78E-06 : 4.60E-06 : 4.47E-06 : 8.29E-04 : 8.12E-04 : O.OOE+00


+-------------- -----------------------------------------

+------------------ +-------------

INFANT : 2.50E-06 : 1.53E-04 : 4.80E-06 : 3.61E-06 : 2.90E-06 : 7.58E-04 : 5.30E-04 : 0.OOE+00


+----------------+------------------------------ --------------------------- +---------------

TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (bREM), JANUARY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 2 A Site Boundary AT .60 MILES NNE ANNUAL BETA AIR DOSE = 2.48E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.31E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-- + ------------------- +--------------------------------------------- -------------- +---------------

PLUME  : 8.27E-04  : 8.27E-04 : 8.27E-04 : 8.27E-04  : 8.27E-04  : 8.27E-04  : 8.52E-04  : 2.15E-03 :

- + -------------------- +-----------------------------------------------------------+---------------

GROUND  : 6.47E-03  : 6.47E-03 : 6.47E-03 : 6.47E-03  : 6.47E-03 : 6.47E-03  : 6.47E-03  : 7.61E-03 :

- + -------------------- +-------------------------------------------+---------------+---------------

VEGET  :  :

ADULT 1.21E-04 9.07E-04 2.82E-04 7.79E-05 3.83E-05 6.07E-03 7.99E-07 0.OOE+00

--- -+ ----------------- +------------------------------ ----------------------------- +---------------

TEEN  : 1.89E-04  : 9.73E-04 : 4.65E-04 : 1.19E-04  : 5.79E-05  : 8.18E-03  : 1.41E-06  : 0.OOE+00 :

- + -------------------- +------------------------------ ----------------------------- +---------------

CHILD  : 3.81E-04  : 6.43E-04 : 1.13E-03 : 1.87E-04  : 9.19E-05 : 1.57E-02  : 2.06E-06 : 0.OOE+00 :

+++-------- ------------------- +------------------------------ +-------------------- +---------------

MEAT  :  :  :  : .  :

ADULT 2.91E-05 2.33E-04 4.93E-06 1.82E-05 3.56E-06 1.64E-04 4.86E-07 0.OOE+00

- + -------------------- +------------------------------ ----------------------------- +---------------

TEEN  : 2.30E-05  : 1.25E-04 : 3.94E-06  : 1.42E-05  : 2.69E-06  : 1.19E-04  : 4.36E-07  : 0.OOE+00 :

+++------- ------------------- +---------------+--------------- +-------------------- +---------------

CHILD  : 3.58E-05  : 6.33E-05 : 7.03E-06  : 1.68E-05  : 3.14E-06  : 1.79E-04  : 4.93E-07  : 0.OOE+00  :

--- -+ ----------------- +------------------------------ ----------------------------- +---------------

COW MILK :  :  :  :  :  :

ADULT  : 2.11E-05 6.55E-05 2.71E-05 3.23E-05 3.41E-05 4.53E-03 6.92E-08 0.OOE+00

+-+----------------+---------------+------------------------------ --------------- +---------------

TEEN  : 3.61E-05  : 7.74E-05 : 4.81E-05  : 5.55E-05  : 5.90E-05  : 7.16E-03  : 1.37E-07  : 0.OOE+00 :

- + -------------------- +------------------------------ ----------------------------- +---------------

CHILD  : 7.07E-05  : 5.18E-05 : 1.14E-04  : 8.98E-05  : 9.51E-05 : 1.41E-02  : 2.03E-07 : 0.OOE+00  :

- + -------------------- +------------------------------ ----------------------------- +---------------

INFANT : 1.14E-04  : 9.71E-05 : 2.17E-04  :-1.88E-04  : 1.55E-04  : 3.44E-02  : 4.07E-07  : 0.OOE+00 :

--+ ------------------- +------------------------------ ----------------------------- +---------------

GOATMILK  : .  :  :  :  :

ADULT  : 1.20E-05 1.58E-05 3.84E-05 1.92E-05 2.98E-05 5.43E-03 4.55E-08 0.OOE+00

--- -+ ----------------- +------------------------------ ----------------------------- +---------------

TEEN  : 2.01E-05  : 2.OOE-05  : 7.02E-05  : 3.38E-05  : 5.30E-05  : 8.59E-03  : 9.32E-08.: 0.OOE+00 :

- + -------------------- +------------------------------ ----------------------------- +---------------

CHILD  : 3.81E-05  : 1.47E-05 : 1.72E-04  : 5.81E-05  : 8.77E-05 : 1.70E-02  : 1.42E-07 : 0.OOE+00 :

- + -------------------- +------------------------------ ----------------------------- +---------------

INFANT  : 6.95E-05  : 2.01E-05  : 3.35E-04  : 1.38E-04  : 1.51E-04  : 4.12E-02  : 2.63E-07 : 0.OOE+00 :

- + -------------------- +------------------------------ ----------------------------- +---------------

INHAL .  :

ADULT 1.88E-06 2.45E-05 2.29E-06 2.42E-06 2.31E-06 3.94E-04 4.42E-04 0.OOE+00

- + -------------------- +-----------------------------------------------------------+---------------

TEEN  : 2.49E-06  : 3.32E-05 : 3.24E-06  : 3.25E-06  : 3.15E-06  : 4.87E-04  : 6.49E-04  : 0.OOE+00 :

+---- ------------------------------ +-------------------------------------------------------------

CHILD  : 2.77E-06  : 1.18E-04 : 4.43E-06  : 3.01E-06  : 2.94E-06  : 5.46E-04  : 5.28E-04  : 0.OOE+00 :

- + -------------------- +------------------------------ ----------------------------- +---------------

INFANT  : 1.63E-06  : 9.96E-05 : 3.14E-06  : 2.37E-06  : 1.91E-06  : 4.99E-04  : 3.44E-04  : 0.OOE+00 :

-+-+ - - -+-------------------------------+----------------------------+---------------

TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 3 A Nearest Resident AT .90 MILES NW ANNUAL BETA AIR DOSE = 1.81E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.90E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

--+ ------------------- +--------------------------------------------- +-----------------------------

PLUME  : 1.26E-03 : 1.26E-03  : 1.26E-03 : 1.26E-03 : 1.26E-03  : 1.26E-03  : 1.28E-03 : 2.65E-03  :

- + -------------------- +--------------------------------------------+------------------------------

GROUND  : 4.16E-03 : 4.16E-03 : 4.16E-03 : 4.16E-03 : 4.16E-03 : 4.16E-03 : 4.16E-03 : 4.89E-03  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :  :

ADULT 8.02E-05 5.85E-04 1.93E-04 5.41E-05 3.11E-05 5.10E-03 5.44E-07 0.OOE+00

- + -------------------- +--------------------------------------------+------------------------------

TEEN  : 1.25E-04 : 6.28E-04  : 3.17E-04  : 8.26E-05 : 4.70E-05 : 6.88E-03  : 9.61E-07  : 0.OOE+00  :

-+ --------------------------------

++--------------- +----------------------------------- ----------

CHILD  : 2.52E-04  : 4.15E-04  : 7.69E-04  : 1.30E-04  : 7.48E-05 : 1.32E-02  : 1.41E-06 : 0.OOE+00  :


+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  : .  :  : .  :

ADULT 1.88E-05 1.49E-04 3.36E-06 1.18E-05 2.49E-06 1.38E-04 3.13E-07 0.OOE+00

- + -------------------- +--------------------------------------------+------------------------------

TEEN  : 1.49E-05 : 8.05E-05  : 2.69E-06 : 9.21E-06 : 1.89E-06 : 9.97E-05  : 2.81E-07  : 0.OOE+00  :

- ++------------------+---------------+--------------- --------------------------------------------

CHILD  : 2.31E-05 : 4.07E-05 : 4.79E-06 : 1.09E-05 : 2.22E-06 : 1.51E-04 : 3.18E-07 : 0.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :  :  :  :

ADULT  : 1.53E-05 4.29E-05 1.99E-05 2.38E-05 2.68E-05 3.80E-03 6.71E-08 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 2.60E-05 : 5.09E-05  : 3.54E-05  : 4.11E-05 : 4.65E-05 : 6.02E-03  : 1.34E-07  : 0.OOE+00  :

- +++--------------------------------------------------------------+------------------------------

CHILD  : 5.05E-05 : 3.41E-05  : 8.42E-05  : 6.70E-05  : 7.54E-05 : 1.19E-02  : 2.02E-07  : 0.OOE+00  :

- +++--------------------------------------------------------------+------------------------------

INFANT  : 8.25E-05 : 6.35E-05 : 1.61E-04 : 1.43E-04 : 1.25E-04 : 2.89E-02 : 3.92E-07 : 0.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : .  :  :  :  :

ADULT  : 1.OOE-05 1.11E-05 2.83E-05 1.62E-05 2.50E-05 4.57E-03 9.77E-08 0.OOE+00

- -------------------------------------------------- +---------------+----------------------------

TEEN  : 1.64E-05 : 1.42E-05 : 5.16E-05 : 2.87E-05 : 4.45E-05 : 7.22E-03 : 2.01E-07 : 0.OOE+00  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD . 3.06E-05 : 1.05E-05 : 1.26E-04 : 4.94E-05 : 7.37E-05 : 1.43E-02 : 3.09E-07 : 0.OOE+00  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 5.61E-05 : 1.40E-05 : 2.45E-04 : 1.17E-04 : 1.27E-04 : 3.47E-02 : 5.62E-07 : 0.OOE+00  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL  :  :  :

ADULT 6.66E-07 8.21E-06 8.24E-07 8.86E-07 8.85E-07 1.48E-04 1.46E-04 0.OOE+00 S+++------------------+---------------+--------------- -----


+---------------+---------------

TEEN  : 8.82E-07 : 1.13E-05 : 1.16E-06 : 1.19E-06 : 1.21E-06 : 1.83E-04 : 2.15E-04 : 0.OOE+00 :


--------------------- +---------------+----------------------------

CHILD  : 9.81E-07  : 4.10E-05  : 1.59E-06  : 1.11E-06 : 1.13E-06 : 2.05E-04  : 1.75E-04  : 0.OOE+00  :

+ -------------------------------------------------------------- +-------------------------

INFANT  : 5.86E-07 : 3.47E-05  : 1.13E-06  : 8.89E-07 : 7.33E-07 : 1.87E-04  : 1.14E-04  : 0.OOE+00  :

-+-+------------------+--------------------------------------------+------------------------------

TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 5.75E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 7.94E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

+----- +---------------+--------------- +----------- ---------------

PLUME  : 5.31E-04 : 5.31E-04  : 5.31E-04  : 5.31E-04  : 5.31E-04  : 5.31E-04 - 5.37E-04  : 1.06E-03  :

+-------------------+---------------+---------------+---------------+---------------+-------------------------------+

GROUND  : 1.37E-04 : 1.37E-04 : 1.37E-04 : 1.37E-04 : 1.37E-04 : 1.37E-04 : 1.37E-04 : 1.61E-04  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  : .  :  :

ADULT 2.76E-06 1.93E-05 6.89E-06 1.97E-06 1.32E-06 2.24E-04 1.93E-08 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 4.27E-06 : 2.08E-05 : 1.13E-05 : 3.OOE-06.: 2.OOE-06 : 3.02E-04 : 3.43E-08 : 0.OOE+00  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 8.57E-06 : 1.37E-05 : 2.73E-05 : 4.77E-06 : 3.20E-06 : 5.79E-04 : 5.04E-08 : 0.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT .  :  :  :

ADULT 6.21E-07 4.92E-06 1.19E-07 3.96E-07 9.08E-08 6.04E-06 1.03E-08 0.OOE+00 S+-------+-------------+---------------+---------------+---------------+---------------+-----------+---------------+

TEEN  : 4.92E-07 : 2.65E-06 : 9.54E-08 : 3.08E-07 : 6.94E-08 : 4.37E-06 : 9.27E-09 : 0.OOE+00  :

S+-------+-------------+---------------+-----------+---------------+---------------+---------------+---------------+

CHILD  : 7.63E-07 : 1.34E-06 : 1.70E'-07 : 3.67E-07 : 8.22E-08 : 6.60E-06 : 1.05E-08 : 0.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  : . .  : .

ADULT  : 5.87E-07 1.45E-06 7.72E-07 9.24E-07 1.11E-06 1.67E-04 3.28E-09 0.OOE+00


+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 9.87E-07 : 1.73E-06 : 1.37E-06 : 1.60E-06 : 1.93E-06 : 2.64E-04 : 6.64E-09 : O.OOE+00 :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.90E-06 : 1.16E-06 : 3.27E-06 : 2.64E-06 : 3.15E-06 : 5.22E-04 : 1.01E-08 : 0.OOE+00 :

++------------------+------------------------------ +- +--------------------------------------------

INFANT : 3.15E-06 : 2.14E-06 : 6.29E-06 : 5.76E-06 : 5.25E-06 : 1.27E-03 : 1.90E-08 : 0.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  : . . .

ADULT  : 4.37E-07 4.12E-07 1.10E-06 7.16E-07 1.10E-06 2.00E-04 6.46E-09 0.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TEEN  : 7.07E-07 : 5.28E-07 : 2.OOE-06 : 1.27E-06 : 1.95E-06 : 3.17E-04 : 1.33E-08 0.OOE+00  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

CHILD  : 1.29E-06 : 3.94E-07 : 4.87E-06 : 2.19E-06 : 3.24E-06 : 6.26E-04 : 2.05E-08 : 0.00E+00  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT  : 2.37E-06 : 5.10E-07 : 9.46E-06 : 5.19E-06 : 5.59E-06 : 1.52E-03 : 3.72E-08 : O.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL . .  :  :

ADULT 7.55E-08 7.20E-07 9.74E-08 1.11E-07 1.25E-07 1.98E-05 1.24E-05 0.00E+00

-- ------ - ------------------ +---------------+----------------+--------------------- --------------- +

TEEN  : 9.98E-08  : 8.71E-07  : 1.37E-07 : 1.50E-07  : 1.71E-07  : 2.45E-05  : 1.81E-05  : O.OOE+00 :

+-------------------------------------------------------------------------------------------------

CHILD  : 1.11E-07  : 2.20E-06  : 1.86E-07 : 1.42E-07  : 1.60E-07  : 2.75E-05  : 1.47E-05  : 0.OOE+00  :

-- ------ - ------------------ +---------------+----------------+--------------------- --------------- +

INFANT  : 6.95E-08  : 1.81E-06  : 1.34E-07 : 1.19E-07  : 1.04E-07  : 2.51E-05  : 9.59E-06  : 0.00E+00  :

-++-------------------- -------------- +---------------+-


--------------- +

TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-DECEMBER 2009 (Continued)

SPECIAL LOCATION NO. 5 A Nearest Garden AT 1.30 MILES SW ANNUAL BETA AIR DOSE = 8.63E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 1.09E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+--*-----------------+--------------------------------------------- ------------- +---------------+

PLUME  : 7.25E-04  : 7.25E-04  : 7.25E-04  : 7.25E-04 : 7.25E-04  : 7.25E-04  : 7.34E-04  : 1.47E-03  :

S+----------------+---------------+--------------- ------------------------------------------ +

GROUND  : 6.36E-04 : 6.36E-04 : 6.36E-04 : 6.36E-04 : 6.36E-04 : 6.36E-04 : 6.36E-04 : 7.48E-04  :

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  :  :  :

ADULT 1.26E-05 8.98E-05 3.10E-05 8.80E-06 5.60E-06 9.38E-04 8.71E-08 0.OOE+00

+---*---------------------------------+---------------+--------------- +---------- --------------- +

TEEN  : 1.96E-05 : 9.63E-05  : 5.09E-05  : 1.34E-05  : 8.48E-06  : 1.27E-03  : 1.55E-07  : 0.OOE+00  :

S+ ------------ +---------------+---------------+

+------------------+------------------------------

CHILD  : 3.93E-05 : 6.38E-05  : 1.23E-04  : 2.13E-05  : 1.35E-05  : 2.43E-03  : 2.27E-07  : 0.OOE+00  :


+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  : " .  :  :  :

ADULT 2.88E-06 2.29E-05 5.39E-07 1.83E-06 4.06E-07 2.53E-05 4.81E-08 0.OOE+00

+---*-----------------+----------------------------------------------------------+---------------+

TEEN  : 2.28E-06  : 1.23E-05 : 4.31E-07  : 1.42E-06 : 3.09E-07 : 1.83E-05 4.31E-08 O.OOE+00

- - - -+-----------------------------------------+-------------------------------- -- +

CHILD  : 3.54E-06 : 6.23E-06 : 7.68E-07 : 1.69E-06 : 3.65E-07 : 2.77E-05 4.87E-08 O.OOE+00 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK  :  :  :

ADULT  : 2.58E-06 6.68E-06 3.37E-06 4.04E-06 4.73E-06 7.OOE-04 1.32E-08 0.OOE+00

+---*-----------------+----------------------------------------------------------+---------------+

TEEN  : 4.35E-06 : 7.93E-06 : 6.01E-06  : 6.99E-06  : 8.26E-06  : 1.11E-03 : 2.67E-08  : 0.OOE+00  :

+---*-----------------+----------------------------------------------------------+---------------+

CHILD  : 8.40E-06 : 5.34E-06  : 1.43E-05  : 1.15E-05  : 1.34E-05 : 2.19E-03  : 4.04E-08  : O.OOE+00 :

+---*-----------------+----------------------------------------------------------+---------------+

INFANT : 1.39E-05 : 9.87E-06 : 2.74E-05 : 2.49E-05 : 2.23E-05 : 5.32E-03 : 7.70E-08 : 0.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GOATMILK  :  :  :  :  :  :

ADULT  : 1.84E-06 1.83E-06 4.81E-06 3.OOE-06 4.60E-06 8.40E-04 2.40E-08 O.OOE+00 S+


+---------------+--------------- ------------ +---------------+---------------+

TEEN  : 2.98E-06  : 2.34E-06  : 8.74E-06  : 5.30E-06  : 8.19E-06  : 1.33E-03 : 4.94E-08  : 0.OOE+00  :

-+----- S+ +-----------------+---------------+---------------+--------------------- --------------- +

CHILD  : 5.50E-06  : 1.74E-06 : 2.13E-05  : 9.15E-06  : 1.36E-05  : 2.63E-03  : 7.59E-08  : O.OOE+00 :

S+ +-----------------+---------------+---------------+----------------------+----- --------------- +

INFANT : 1.01E-05 : 2.28E-06 : 4.15E-05 : 2.17E-05 : 2.35E-05 : 6.38E-03 : 1.38E-07 : 0.OOE+00  :

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

INHAL -  :  : .  :  :

ADULT  : 1.87E-07 2.14E-06 2.36E-07 2.59E-07 2.73E-07 4.44E-05 3.72E-05 0.OOE+00

+---*------------------------------------------------ -------

  • --------------------+---------------+

TEEN  : 2.48E-07  : 3.03E-06 : 3.32E-07  : 3.50E-07  : 3.73E-07  : 5.49E-05  : 5.47E-05 : O.OOE+00 :

+---*------------------------------------------------ ---------------------------- +---------------+

CHILD  : 2.76E-07 : 1.13E-05 : 4.52E-07 : 3.28E-07 : 3.48E-07 : 6.16E-05 : 4.45E-05 : O.OOE+00 :

S+-------+---------+---------------+---------------+---------------+---------------+---------------+---------------+

INFANT : 1.68E-07 : 9.59E-06 : 3.24E-07 : 2.68E-07 : 2.27E-07 : 5.63E-05 : 2.91E-05 : 0.OOE+00 :

-+--*-----------------+----------------------------------------------------------+---------------+

TABLE 8. DOSES TO POPULATION WITHIN 50 MILES, JANUARY-MARCH 2009 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

PLUME  : 1.13E-03 : 1.13E-03 : 1.13E-03 : 1.13E-03 : 1.13E-03 1.13E-03 : 1.15E-03 : 2.53E-03 95.52% 94.81% 94.10% 95.47% : 95.25% 39.58% : 95.44% : 97.83%

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

GROUND  : 4.78E-05 : 4.78E-05 : 4.78E-05 : 4.78E-05 : 4.78E-05 4.78E-05 : 4.78E-05 : 5.62E-05 4.02% 4.00% : 3.97% : 4.02% : 4.01% 1.67% : 3.96% : 2.17%

.. . --. + -- ++------------------------------------------------------------ +--------------------------

INHAL  : 1.94E-07 7.01E-07 : 4.OOE-07 : 3.23E-07 : 5.23E-07 9.86E-05 7.20E-06 : 0.OOE+00

.02%: .06%: .03%: .03%: .04%: 3.44%: .60%: .00%:

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET  : 1.83E-06 : 8.89E-06 : 1.55E-05 : 6.19E-07 : 1.07E-07 : 1.99E-05 : 0.OOE+00 : 0.OOE+00

.15%: .74%: 1.29%: .05%: .01%: .69%: .00%: .00%:

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK : 2.94E-06 : 1.99E-06 : 7.02E-06 : 4.81E-06 . 7.97E-06 : 1.53E-03 : 1.37E-34 : 0.OOE+00

.25% : .17% : .58% : .40% : .67% : 53.48% : .00% : .00%


+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  : 4.47E-07  : 2.65E-06 : 3.57E-07 : 2.63E-07 : 1.70E-07 : 3.24E-05 : 0.OOE+00 : 0.OOE+00

.04%  : .22% : .03% : .02% : .01% : 1.13% : .00% : .00%

  • 1------------------ --------------

0---------------0---------------01----------- --------------- 0

  • TOTAL*  : 1.19E-03  : 1.20E-03  : 1.20E-03  : 1.19E-03  : 1.19E-03  : 2.86E-03  : 1.21E-03  : 2.59E-03

TABLE 9. DOSES TO POPULATION WITHIN 50 MILES, APRIL-JUNE 2009 ALARA ANNUAL INTEGRATED POPULATION DOSE SUdMMARY (PERSON-REM)

PATHWAY T.BODY, . GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

- -- + + -----------------

+ +---------------+---------------

F---------- ----------

+ --------------- +

PLUME  : 2.04E-05 2.04E-05 2.04E-05 2.04E-05 2.04E-05 2.04E-05 2.07E-05 4.91E-05 15.67% 13.38% 15.48% 15.97% 16.13% 4.79% 14.99% 28.53%

+ -------------------------------------------------------------------- ------------ +---------------+

GROUND 1.05E-04 1.05E-04 1.05E-04 1.05E-04 1.05E-04 1.05E-04 1.05E-04 1.23E-04 80.22% 68.52% 79.26% 81.76% 82.60% 24.51% 75.58% 71.47%

+ ----------------------- +----------------------------+--------------- ++--------- ---------------

INHAL 6.82E-08 8.38E-07 9.27E-08 9.02E-08 1.10E-07 1.84E-05 1.30E-05 0.OOE+00

.05% .55%9 .07%9 .07%9 .09%9 4.31% 9.42% .00%

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

VEGET 3.40E-06 1.81E-05 5.02E-06 1.35E-06 2.56E-08 3.34E-06 : 2.89E-09 0.OOE+00

2.61% 11.89% 3.80% 1.05% .02% .78%: .00% .00%

+ -------------------------------------------------------------------- ------------ +---------------+

COW MILK 9.55E-07 2.38E-06 1.72E-06 1.05E-06 1.44E-06 2.74E-04 3.87E-09 0.OOE+00

.73% 1.56% 1.30% .82% 1.14% 64.29% .00% .00%

+- -+------------------+--------------------------------------------- ------------- +---------------+

NEAT 9.35E-07 6.27E-06 1.05E-07 4.13E-07 3.04E-08 5.68E-06 2.25E-10 0.OOE+00

.72% 4.10% .08% .32% .02% 1.33% .00% .00%

+ -------------------------------------------------------------------- ------------- +---------------

  • TOTAL*  : 1.30E-04  : 1.53E-04  : 1.32E-04 : 1.28E-04  : 1.27E-04  : 4.27E-04  : 1.38E-04  : 1.72E-04

+ ----------------------- +------------------------------ ----------------------------- +-------------

TABLE 10. DOSES TO POPULATION WITHIN 50 MILES, JANUARY-JUNE 2009 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


-+--------------------------------+------------------------------ ---------------------------- +

PLUME  : 1.12E-03 : 1.12E-03 : 1.12E-03 1.12E-03 : 1.12E-03 : 1.12E-03 1.14E-03 : 2.52E-03 87.15% 85.09% : 85.85% 87.27% 87.17% : 34.17% 86.64% : 93.25%

+---*---------------------------------+------------------------------ ---------------------------- +

GROUND  : 1.55E-04 : 1.55E-04 1.55E-04 : 1.55E-04 : 1.55E-04 1.55E-04 : 1.55E-04 1.82E-04 12.02% : 11.73% : 11.84% 12.03% : 12.02% 4.71% : 11.77% : 6.75%

+---*---------------------------------+------------------------------ ---------------------------- +

INHAL  : 2.61E-07 1.57E-06 : 4.81E-07 4.11E-07 : 6.28E-07 : 1.16E-04 : 2.09E-05 : 0.OOE+00

.02% .12% : .04% .03% : .05% : 3.52% 1.59% : .00%

S+-----------------+---------------+------------------------------ --------------------------- +

VEGET_ 5.22E-06 : 2.70E-05 : 2.05E-05 1.97E-06 : 1.34E-07 2.35E-05 : 2.82E-09 : 0.OOE+00

.40% 2.05% 1.57% : .15% : .01% .71% : .00% .00%

+.-+".-------------------------------+---------------+--------------- +


--------------- +

COW MILK : 3.95E-06 4.38E-06 : 8.80E-06 : 5.94E-06 : 9.54E-06 : 1.83E-03 : 3.76E-09 : 0.OOE+00

.31% : .33% .67% .46% : .74% : 55.70% : .00% : .00%

-+--*--+------------------------------+---------------+--------------- --------------------------- +

MEAT  : 1.38E-06 : 8.92E-06 : 4.63E-07 : 6.77E-07 : 2.03E-07 : 3.86E-05 : 2.19E-10 : 0.OOE+00

.11%: .68%: .04%: .05%: .02%: 1.17%: .00%: .00%:

- - +-----------------------------------+---------------+--------------- +----------- --------------- +

  • TOTAL*  : 1.29E-03  : 1.32E-03  : 1.31E-03  : 1.29E-03  : 1.29E-03 : 3.29E-03  : 1.32E-03 : 2.70E-03

-- +----+------------------------------+--------------- ------------------------------------------- +

TABLE 11. DOSES TO POPULATION WITHIN 50 MILES, JULY-SEPTEMBER 2009 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN


+------------------------------+------------------------------ --------------------------- +

PLUME  : 7.42E-05 : 7.42E-05 7.42E-05 : 7.42E-05 : 7.42E-05 : 7.42E-05 7.74E-05 : 2.39E-04 46.65% 42.35% 46.46% : 47.08% : 47.53% 29.05% : 44.69% : 71.53%

+--------------------------------------+------------------------------ --------------------------- +

GROUND  : 8.08E-05 : 8.08E-05 8.08E-05 8.08E-05 8.08E-05 : 8.08E-05 : 8.08E-05 : 9.50E-05 50.79% : 46.11% 50.59% 51.27% : 51.76% : 31.64% 46.61% : 28.47%

+--------------------------------------+------------------------------ --------------------------- +

INHAL 5.98E-08 7.40E-07 : 7.49E-08 6.91E-08 : 6.14E-08 9.66E-06 1.51E-05 : 0.OOE+00

.04% .42% : .05%: .04% : .04% 3.78% 8.70%: .00%:

- -- -*--------------------------------+---------------+---------------+L --------------------------- +

VEGET  : 2.48E-06 : 1.31E-05 : 3.43E-06 : 1.11E-06 : 1.01E-07 1.03E-06 : 1.14E-11 : 0.OOE+00 1.56% : 7.46% : 2.15% : .70% : .06% : .40% : .00% : .00%

+--------------------------------------+------------------------------ --------------------------- +

COW MILK : 8.27E-07 : 1.90E-06 : 1.11E-06 : 1.05E-06 : 8.85E-07 : 8.79E-05 : 1.09E-11 : 0.OOE+00

.52% : 1.09% : .69% " .67% : .57% : 34.42% : .00% : .00%

++.---- ------------------------------- +---------------+---------------+--------------------------+

MEAT 7.03E-07 : 4.51E-06 : 9.31E-08 : 3.73E-07 : 6.64E-08 : 1.80E-06 : 1.46E-12 : 0.OOE+00

.44% : 2.57% : .06% : .24% .04% . .70% : .00% : .00%

+--------------------------------------+------------------------------ --------------------------- +

  • TOTAL*  : 1.59E-04  : 1.75E-04  : 1.60E-04  : 1.58E-04  : 1.56E-04  : 2.55E-04  : 1.73E-04  : 3.34E-04

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

00

TABLE 12. DOSES TO POPULATION WITHIN 50 MILES, OCTOBER-DECEMBER 2009 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T. BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-..- +--- -------------------------------

+---------------+---------------+----------- ---------------

PLUME 1.20E-04 : 1.20E-04 : 1.20E-04 : 1.20E-04 : 1.20E-04 1.20E-04 1.24E-04 3.11E-04 30.51% : 26.84% : 31.03% : 30.71% 31.28% 21.01% 28.81% 50.55%

..- +--- ------------------------------- +---------------+---------------+---------------------------

GROUND  : 2.59E-04 : 2.59E-04 2.59E-04 2.59E-04 : 2.59E-04 : 2.59E-04 : 2.59E-04 : 3.04E-04 65.81% : 57.90% : 66.94% : 66.26% : 67.48% 45.32% : 60.27% : 49.45%

..- +--- ------------------------------- +------------------

- +-------- ---------------- +-------------

INHAL 1.73E-07 : 2.34E-06 : 1.06E-07 2.16E-07 : 1.34E-07 : 1.64E-05 : 4.66E-05 : 0.OOE+00

.04%: .52%: .03%: .06%: .03%: 2.87%: 10.87%: .00%:

S+------------+---------------+---------------+---------------+---------------+ -------------- +---------------+

VEGET  : 8.30E-06 : 4.33E-05 : 4.84E-06 : 4.73E-06 " 7.34E-07 : 2.14E-06 : 7.31E-08 : 0.OOE+00 2.11% : 9.70% : 1.25% : 1.21% : .19% : .37% : .02% : .00%

S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK : 3.49E-06 : 6.95E-06 : 2.50E-06 : 5.15E-06 " 3.51E-06 : 1.70E-04 : 4.43E-08 : 0.OOE+00

.89% : 1.56% : .65% : 1.32% : .92% : 29.81% : .01% : .00%


+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

MEAT  : 2.51E-06  : 1.56E-05 : 3.63E-07 : 1.72E-06 : 3.66E-07 : 3.57E-06 : 7.42E-08 : 0.OOE+00

.64%  : 3.48% : .09% : .44% : .10% : .63% : .02% : .00%

9---

-0E------------------------------0---------------0---------------09----------- --------------- 0

  • TOTAL*  : 3.93E-04 : 4.47E-04 : 3.86E-04 : 3.90E-04 : 3.83E-04 : 5.71E-04 : 4.29E-04 : 6.15E-04 S+-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

TABLE 13. DOSES TO POPULATION WITHIN 50 MILES, JULY-DECEMBER 2009 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

+--------------------------------------+---------------+--------------- ---------------------------

PLUME  : 1.90E-04 1.90E-04 1.90E-04 : 1,.90E-04 : 1.90E-04 : 1.90E-04 : 1.96E-04 : 5.34E-04 34.46% 30.57% : 34.83% : 34.72% : 35.27% : 22.90% : 32.65% : 57.02%

+--------------------------------------+---------------+--------------- ---------------------------

GROUND 3.42E-04 : 3.42E-04 : 3.42E-04 3.42E-04 3.42E-04 : 3.42E-04 3.42E-04 : 4.02E-04 62.17% : 55.15% : 62.84% 62.63% 63.63% : 41.31% 56.86% : 42.98%

-.. ------- .+----------.---------------.---------------.---------------.---------------..--------------------------+

INHAL  : 2.39E-07 : 3.14E-06 : 1.92E-07 2.96E-07 : 2.05E-07 : 2.73E-05 6.29E-05 : 0.00E+00

.04% : .51%: .04%: .05%: .04%: 3.29%: 10.46%; .00%:

+--------------------------------------+---------------+--------------- +----------- ---------------

VEGET  : 1.08E-05 : 5.64E-05 : 8.38E-06 : 5.84E-06 : 8.37E-07 : 3.19E-06 : 7.37E-08 : 0.00E+00 1.96% : 9.10% : 1.54% : 1.07% : .16% : .39% : .01% : .00%

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK : 4.32E-06 : 8.87E-06 : 3.64E-06 : 6.22E-06 : 4.41E-06 : 2.60E-04 : 4.53E-08 " 0.OOE+00

.79%: 1.43% : .67% : 1.14% : .82% : 31.46% : .01% : .00%


---------------------------------------------- +---------------+ ------------------------------

MEAT  : 3.21E-06 : 2.01E-05 : 4.58E-07 : 2.09E-06 : 4.33E-07 : 5.42E-06  : 7.43E-08 : 0.OOE+00

.58% : 3.24% : .08% : .38% : .08% : .65%  : .01% : .00%

+--------------------------------------+---------------+--------------- ---------------------------

  • TOTAL*  : 5.50E-04  : 6.20E-04  : 5.44E-04  : 5.46E-04  : 5.37E-04  : 8.28E-04  : 6.01E-04  : 9.36E-04

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

÷( A÷+

C*

TABLE 14. DOSES TO POPULATION WITHIN 50 MILES, JANUARY-DECEMBER 2009 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

+--------+------------------------------+---------------+--------------- +---------- ---------------

PLUME 1.30E-03 : 1.30E-03 1.30E-03 1.30E-03 : 1.30E-03 : 1.30E-03 1.33E-03 : 3.04E-03 71.25% : 67.52% : 70.73% 71.48% : 71.76% : 31.78% 69.74% 83.88%

+--------+------------------------------+---------------+--------------- +---------- ---------------

GROUND  : 4.97E-04 4.97E-04 : 4.97E-04 : 4.97E-04 4.97E-04 4.97E-04 : 4.97E-04 : 5.84E-04 27.14% : 25.72% 26.95% 27.23% : 27.34% 12.11% : 26.09% 16.12%

+--------+------------------------------+---------------+--------------- +---------- ---------------

INHAL 5.16E-07 : 4.57E-06 : 7.40E-07 7.41E-07 : 9.20E-07 1.61E-04 : 7.92E-05 0.00E+00

.03%: .24%: .04%: .04%: .05%: 3.92%: 4.16%: .00%:

+--------+------------------------------+---------------+--------------- +---------- ---------------

VEGET  : 1.60E-05 : 8.36E-05 : 2.89E-05 : 7.83E-06 : 9.71E-07 : 2.65E-05 : 7.67E-08 : 0.OOE+00

.88% : 4.33% : 1.57% : .43% : .05% : .64% : .00% : .00%

- +-------+-----------+---------------+---------------+---------------+---------------+---------------+---------------+

COW MILK : 8.24E-06 : 1.33E-05 : 1.24E-05 : 1.21E-05 : 1.39E-05 : 2.07E-03 : 4.94E-08 : 0.OOE+00

.45%: .69%: .67%: .66%: .76%: 50.49%: .00%: .00%:

-+------------------------------------+---------------+----------------+----------- ---------------

MEAT  : 4.60E-06 : 2.91E-05 : 9.20E-07 : 2.77E-06 : 6.34E-07 : 4.37E-05 : 7.45E-08 : 0.00E+00

.25% : 1.51% : .05% : .15% : .03% : 1.07% : .00% : .00%

+--------+------------------------------+---------------+--------------- +÷--------- ---------------

  • TOTAL*  : 1.83E-03  : 1.93E-03  : 1.84E-03 : 1.82E-03  : 1.82E-03  : 4.10E-03  : 1.90E-03 : 3.63E-03

+--------+------------------------------+--------------- +------------------------+---------------

Oi

DOSE CALCULATION MODELS To evaluate the radiological consequences of the routine release of liquid and gaseous effluents from the Cooper Nuclear Station, two computer codes were used: LADTAP II for liquid doses and GASPAR for gaseous doses. Both of these computer codes implement the dose calculational methodologies of U.S. NRC Regulatory Guide 1.109, Revision 1.

Source terms for each quarter are combined with station-specific demographic data and either hydrological dilution factors, for liquid dose calculations, or atmospheric diffusion estimates, for gaseous dose calculations.

For liquid dose calculations, the hydrological dilution factors used for input to LADTAP II, as well as other input parameters, are listed in Table 15. Other inputs not specifically listed in this table are taken from Regulatory Guide 1.109, Revision 1. Semiannual doses are obtained by summing the contributions from the appropriate quarters.

For gaseous dose calculations, atmospheric diffusion estimates are obtained from the reduction and processing of onsite meteorological data. Source terms for the semiannual period are obtained by summing source terms for the appropriate quarters. Additional input to GASPAR includes the following station-supplied data:

- 0 to 50 mile population distribution

- 0 to 50 mile meat, milk, and vegetable distributions

- Absolute humidity at Cooper Nuclear Station (14.61 g/m3)

- The fraction of the year that the vegetables are grown (0.5)

- The fraction of the daily feed intake derived from pasture for milk and meat animals (0.5)

Other values used for input to GASPAR are default values from Regulatory Guide 1.109, Rev. 1.

F-52

TABLE 15. Values of Parameters Used to Make Dose Estimates Resulting From Liquid Discharges at Cooper Nuclear Station January-December 2009 Values Assigned Parameter Individual, Population Cooling flow rate (cfs)

  • Q1 NR NR (Average daily value) Q2 NR NR Q3 1388.83 1388.83 Q4 NR NR Dilution factor* Q1 NR NR Q2 NR NR Q3 1 32.01 Q4 NR NR Holding time:

Fish 24 hr *** 168 hr ***

Drinking water 12 hr *** 22.4 hr **

Shoreline exposure 0 hr *** 22.4 hr **

Swimming 0 hr

  • 22.4 hr **

Boating 0 hr *** 22.4 hr **

Ql, Q2, Q3, and Q4 represent first, second, third and fourth quarter station data for 2009, respectively.

    • Based on an average Missouri River water flow of 5.5 ft/sec, 84 miles down the river.

NR- No release F-53

REFERENCES U.S. Nuclear Regulatory Commission, Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants", Revision 1, 1974.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.23 (Safety Guide 23), "Onsite Meteorological Programs", Revision 0, 1972.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors", Revision 1, 1977.

U.S. Nuclear Regulatory Commission, NUREG/CR-2919, "XOQDOQ: Computer Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations", 1982.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors", Revision 0, 1976.

U.S. Nuclear Regulatory Commission, NUREG-0597, "User's Guide to GASPAR Code",

December 1980.

U.S. Nuclear Regulatory Commission, NUREG/CR-1276, "User's Manual for LADTAP II: A Computer Code for Calculating Radiation Exposure to Man From Routine Release of Nuclear Reactor Liquid Effluents", 1980.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I", Revision 1, 1977.

F-54

APPENDIX G REMP SAMPLE STATION DESCRIPTIONS G-1

REMP SAMPLE STATION DESCRIPTIONS The following pages contain descriptions of the CNS REMP Sample Stations that were active or were used for part or all of 2009.

G-2

REMP SAMPLE STATION DESCRIPTIONS SAMPLE TYPES AND SAMPLE LOCATIONS Sample Station (a) Sample Description - Type and Location No. 1 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Outside the northwest edge of fence, east of the gate to the LLRW storage pad on the CNS site, NW 1/4, S32, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.38.634 W - Lat. 40.21.523 N No. 2 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: North side of county road to the south portion of CNS site, SW 1/4/, S32, T5N, RI6E, Nemaha County, Nebraska.

Lon. 095.38.954 W - Lat. 40.21.126 N No. 3 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located on the north side of the Brownville State Recreation Park access road near water gauging station, SE 1/4, S18, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.39.108 W - Lat. 40.23.777 N No. 4 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located '/2 mile south of Phelps City, Missouri, on west side of highway "U", NE 1/4, S2, T64N, R42W, Atchison County, Missouri.

Lon. 095.35.792 W - Lat. 40.23.797 N No. 5 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located 1/4A mile south and 1/4 mile east of Langdon, Missouri, on north side of road, west of railroad tracks, SW 1/4, T64N, R41 W, Atchison County, Missouri.

Lon. 095.34.434 W- Lat. 40.21.151 N G-3

Sample Station (a) Sample Description - Type and Location No. 6 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: One mile west of the end of Missouri State Highway "U", SW corner of the intersection, NW 'A, S34, T64N, R42W, Atchison County, Missouri.

Lon. 095.37.620 W - Lat. 40.19.459 N No 7 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: 300 yards east of Highway 67 on north side of road, SW 1/4/4, S6, T4N, R16E, Nemaha, Nebraska.

Lon. 095.40.207 W - Lat. 40.20.287 N No. 8 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: /2mile north, % mile west and 3/4 mile north of Nemaha, on west side of road adjacent to transmission line, NE '/4, S35, T5N, R15E, Nemaha County, Nebraska.

Lon. 095.41.220 W - Lat. 40.21.570 N No. 9 Type: (1)Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Four miles north of Highway 136, on Highway 67.

Then I mile east of Highway 67 and /2 mile north on west side of road, SW A/4,S26, T6N, R15E, Nemaha County, Nebraska.

Lon. 095.41.810 W - Lat. 40.27.259 N No. 10 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: One mile north of Barada, Nebraska, in SW corner of intersection, NE 'A, S14, T3N, R16E, Richardson County, Nebraska.

Lon. 095.34.723 W - Lat. 40.13.970 N G-4

Sample Station (a) Sample Description - Type and Location No. 11 Type: (1) Water-Ground Location: Plant well water supply header at well pits, NW 1/44, S32, T5N, R1 6E, Nemaha County, Nebraska.

Lon. 095.53.866 W-Lat. 40.18.970 N No. 12 Type: (1) Water-River Location: Sample (1) taken from the Missouri River immediately upstream form the Plant Intake Structure (River Mile 532.5). During periods when unsafe conditions warrant, Station 35 may be used as an alternate upstream collection site.

Lon. 095.53.866 W - Lat. 40.18.970 N No.20 Type: (1) Environmental Thermoluminescent Dosimetry Location: On NNW boundary of NPPD property, east side of county road, SE, S30, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.39.226 W - Lat. 40.22.260 N No.28 Type: (1) Water- River, (2) Fish (3) Sediment from Shoreline (4) Food Products - Broadleaf Vegetation Location: Samples (1), (3), and (4) are taken from the Missouri River or its shore downstream near River Mile 530, Sample (2) is taken from the Missouri River '/2 to 3 miles downstream of the plant site.

Lon. 095.37.301 W- Lat. 40.20.336 N G-5

Sample Station (a) Sample Description - Type and Location No. 35 Type: (1) Fish (2) Water - River (Alternate Site)

(3) Food Products - Broadleaf Vegetation Location: Sample (1) will be taken from the Missouri River about 1 to 3 miles above the CNS intake structure. During periods when unsafe conditions warrant, Station 35 may be used as an alternate to Station 12 (upstream collection site) for sample type (2). Sample (3) is taken about 1/4 mile south of the Brownville State Recreation Area in Sector A.

Lon. 095.39.046 W - Lat. 40.23.737 N No. 44 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1/4 mile south of Auburn Country Club on Highway 75, then 1/2 mile east of Highway 75 at fence line north of county road, SEI/4, S27, T5N, R14E, Nemaha County, Nebraska.

Lon. 095.49.759 W- Lat. 40.21.840 N No. 47 Type: (1) Water- Ground Location: At Falls City Municipal water supply well.

Lon. 095.25.537 W - Lat. 40.01.939 N No. 56 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 1/4 miles SW of Langdon, Missouri, on Highway "U",

on the right side of the highway, NW 1/4, S23, T64N, R42W, Atchison County, Missouri.

Lon. 095.36.383 W - Lat. 40.21.157 N No. 58 Type: (1) Environmental Thermoluminescent Dosimetry Location: Three miles south of Brownville, Nebraska, on county road, at the SE corner of the intersection with the farm road leading to Sample Station No. 2, SE 1/4, S31, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.39.338 W - Lat. 40.21.126 N G-6

Sample Station (a) Sample Description - Type and Location No. 59 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile SSE of the CNS Elevated Release Point, in the vicinity of the levee at the south boundary of NPPD property, SE '/4, S32, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.38.223 W - Lat. 40.20.986 N No. 66 Type: (1) Environmental Thermoluminescent Dosimetry Location: Two miles south of Nemaha, Nebraska, on Highway 67 east side of road, NW1/4, S19, T4N, R16E, Nemaha County, Nebraska.

Lon. 095.40.307 W - Lat. 40.18.277 N No. 67 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 miles west of Brownville, Nebraska, on Highway 136, then north 1 1/2A miles on county road and east V2 mile, on north side of road, NE1/4, S11, T5N, RI5E, Nemaha County, Nebraska.

Lon. 095.41.520 W - Lat. 40.24.898 N No. 71 Type: (1) Environmental Thermoluminescent Dosimetry Location: Two miles east of Phelps City, Missouri, on Highway 36, then south 1 1/2/miles on county road and west 1/4 mile, SE1/4, S6, T64N, R41W, Atchison County, Missouri.

Lon. 095.34.727 W- Lat. 40.21.664 N No. 79 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 7/8 miles south of Brownville, NE, on east side of paved road, NPPD property, SE1/4, S30, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.39.238 W - Lat. 40.22.006 N G-7

Sample Station (a) Sample Description - Type and Location No. 80 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 1/8 miles south of Brownville, on east side of paved road, NPPD property, NE 1/4, S31, T5N, R 16E, Nemaha County, Nebraska.

Lon. 095.39.259 W - Lat. 40.21.834 N No. 81 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 3/8 miles south of Brownville, Nebraska, in the NE comer of the intersection of the paved county road and CNS access road, NPPD property, NE1/4, S31, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.39.291 W - Lat. 40.21.582 N No. 82 Type: (1) Environmental Thermoluminescent Dosimetry Location: 7/8 mile south of CNS in a field, on NPPD property, SW1/4, S32, T5N, R16E, Nemaha County, Nebraska.

Lon. 095.3 8.395 W - Lat. 40.20.961 N No. 83 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 1A miles south of Nemaha, Nebraska, on Highway 67, then east I mile to the junction of the driveway and county road (east side of drive), NE 1/4, S 19, T4N, R16E, Nemaha County, Nebraska.

Lon. 095.39.411 W-Lat. 40.18.119 N No. 84 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 '/2 miles west of Brownville, NE, south side of Highway 136 west of Locust Grove School, NWI/4, S22, T5N, RI 5E, Nemaha County, Nebraska.

Lon. 095.42.993 W - Lat. 40.23.564 N G-8 2

Sample Station (a) Sample Description - Type and Location No. 85 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile east of Brownville, Nebraska, on Highway 136, then north /4 mile on the east side of the county road, NE1/4, S33, T65N, R42W, Atchison County, Missouri.

Lon. 095.38.309 W - Lat. 40.24.508 N No. 86 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then north 1 /2 miles on Highway "D" on west side, SE1/4, S22, T65N, R42W, Atchison County, Missouri.

Lon. 095.36.938 W - Lat. 40.25.563 N No. 87 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then south Y1/2 mile on county road and 3/4 mile west on county road to the end of the road, NW1/4, S3, T64N, R42W,)Atchison County, Missouri.

Lon. 095.37.806 W - Lat. 40.23.818 N No. 88 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then south 2 miles at the end of the county road, NW 1/4, S 11, T64N, R42W, Atchison County, Missouri.

Lon. 095.37.771 W - Lat. 40.24.762 N No. 89 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 '/2 miles south of Phelps City, Missouri, on Highway "U", then V mile west in the SE corner of the county road intersection, NE 1/4, S14, T64N, R42W, Atchison County, Missouri.

Lon. 095.36.361 W - Lat. 40.21.962 N G-9

Sample Station (a) Sample Description - Type and Location No. 90 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 / miles west and 3/4 mile south of Langdon, Missouri, on Highway "U", then 1/4 mile west, SW1/4, S23, T64N, R42W, Atchison County, Missouri.

Lon. 095.35.808 W - Lat. 40.19.472 N No. 91 Type: (1) Environmental Thermoluminescent Dosimetry Location: /2 mile west of Rockport, Missouri, on the south side of the intersection of U.S. Highway 136 and U.S.

Highway 275, at the south side of the water tower, NW1/4, S28, T65N, R41W, Atchison County, Missouri.

Lon. 095.32.217 W- Lat. 40.25.181 N No. 94 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1/4 mile of Langdon, Missouri, on the west side of the road, NE1/4, S24, T64N, R42W, Atchison County, Missouri.

Lon. 095.34.673 W - Lat. 40.20.931 N No. 96 Type: (1) Food products - Broadleaf Vegetation Location: Approximately 1 mile south of Brownville, Nebraska, along the paved road, in the road ditch in Sector R, SW 1/4, S 19, T5N, R 16E, Nemaha County, Nebraska.

Lon. 095.39.318 W - Lat. 40.23.144 N No. 99 Type: (1) Milk (Nearest and Other Producer)

Location: 1 1/4 mile south of Shubert, Nebraska, on the west side of Highway 67, NE1/4, S24, T3N, R15E, Richardson County, Nebraska.

Lon. 095.40.368 W - Lat. 40.12.850 N G-10

Sample Station (a) Sample Description - Type and Location No. 101 Type: (1) Food Products - Broadleaf Vegetation Location: 5 1/2 miles east and /2 mile north of Rock Port, Missouri, near the junction of Highway 136 and Highway 59, in Sector D, encompasses portions of several sections, Athison County, Missouri.

Lon. 095.23.822 W - Lat. 40.25.222 N No. 103 Type: (1) Milk (Other Producer)

Location: Four miles south and 3 miles west of Auburn, Nebraska, NE 1/4, S13, T4N, Rl3E, Nemaha County, Nebraska.

Lon. 095.53.865 W-Lat. 40.18.971 N G-11

APPENDIX H ANNUAL RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM (ARGPP) REPORT H-1

NEBRASKA PUBLICPOWER DISTRICT COOPER NUCLEAR STATION RadiologicalGroundwaterProtectionProgram 2009 Annual Report January1, 2009 to December 31, 2009 Prepared by Teledyne Brown Engineering 2508 Quality Lane Knoxville, TN 37931-3133 H-2

Table Of Contents I. Summary .......................................... I................................................................................ 4 HI. Characteristics of Tritium (H-3) ...................................................................................... 6 III. Introduction ...................................................................................................................... 6 A. Objectives of the RGPP ...................................................................................... 7 B. Implementation of the Objectives ......................................................................... 7 C. Program Description ........................................................................................... 7 WV. Program Description ................................................................................................. 8 A. Sample Analysis .............................................................................................. 8 B. Data Interpretation ............................................................................................. 8 V. Results and Discussion ................................................................................................. 9 A. Groundwater Results .......................................................................................... 9 2 H-3

Appendices Appendix A: Location Designation of the Annual Radiological Groundwater Protection Program Report (ARGPPR)

Tables Table A-1: Radiological Groundwater Protection Program - Sampling Locations, Nebraska Public Power District, Cooper Nuclear Station, 2009 MAP Map A- I Routine Well Water Sample Locations for the Radiological Groundwater Protection Program, Nebraska Public Power District, Cooper Nuclear Station, 2009 Appendix B: Data Tables of the Annual Radiological Groundwater Protection Program Report (ARGPPR)

Table B-1: Concentrations of Gross Alpha, Strontium-89/90, Iron-55, Nickel-63, Gamma Emitters and Tritium in Groundwater Samples Collected in the Vicinity of Nebraska Public Power District, Cooper Nuclear Station, 2009.

H-4

I. Summary In 2008, the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) Nebraska Public Power District instituted a comprehensive program to evaluate the impact of station operations on groundwater in the vicinity of CNS. This report covers groundwater samples, collected outside of the Licensee required Off-Site Dose Assessment Manual (ODAM) requirements, both on and off station property in 2009.

During that time period, 308 analyses were performed on 44 samples from 11 locations.

In assessing all the data gathered for this report, it *as concluded that the operation of CNS had no adverse radiological impact on the environment, and there are no known active releases into the groundwater or surface water at Nebraska Public Power District.

Gross alpha was detected in five locations. The concentrations ranged from 2.82 + 1.85 pCi/L to 8.10 +/- 3.30 pCi/L.

Tritium was not detected in any of the groundwater samples at concentrations greater than the United States Environmental Protection Agency (USEPA) drinking water standard (and the Nuclear Regulatory Commission Reporting Limit) of 20,000 pCi/L. The tritium concentrations ranged from 238 +/- 121 pCi/L to 1170 + 181 pCi/L.

Strontium-89 and strontium-90 were not detected at concentrations greater than the Lower Limit of Detection (LLD) as specified in NUREG-1302 in any of the groundwater samples.

Iron-55 was not detected in any of the groundwater samples.

Nickel-63 was not detected in any of the groundwater samples.

Gamma-emitting radionuclides associated with licensed plant operations were not detected at concentrations greater than their respective Lower Limits of Detection (LLDs) as specified in NUREG-1302 in any of the groundwater samples. In the case of tritium, CNS specified that the independent laboratory achieve a lower limit of detection 10 times lower than that required by the United States Environmental Protection Agency (USEPA) regulation.

4 H-5

Intentionally left blank 5

H-6

II. Characteristics of Tritium (H-3)

Tritium (chemical symbol H-3) is a radioactive isotope of hydrogen. The most common form of tritium is tritium oxide, which is also called "tritiated water." The chemical properties of tritium are essentially those of ordinary hydrogen.

Tritiated water behaves the same as ordinary water in both the environment and the body.

Tritium can be taken into the body by drinking water, breathing air, eating food, or absorption through skin. Once tritium enters the body, it disperses quickly and is uniformly distributed throughout the body. Tritium is excreted primarily through urine with a clearance rate characterized by an effective biological half-life of about 14 days.

Within one month or so after ingestion, essentially all tritium is cleared. Organically bound tritium (tritium that is incorporated in organic compounds) can remain in the body for a longer period.

Tritium is produced naturally in the upper atmosphere when cosmic rays strike air molecules. Tritium is also produced during nuclear weapons explosions, as a by-product in reactors producing electricity, and in special production reactors, where the isotopes lithium-7 and/or boron-10 are activated to produce tritium. Like normal water, tritiated water is colorless and odorless. Tritiated water behaves chemically and physically like non-tritiated water in the subsurface, and therefore tritiated water will travel at the same velocity as the average groundwater velocity.

Tritium has a half-life of approximately 12.3 years. It decays spontaneously to helium-3 (3He). This radioactive decay releases a beta particle (low-energy electron). The radioactive decay of tritium is the source of the health risk from exposure to tritium.

Tritium is one of the least dangerous radionuclides because it emits very weak beta radiation and leaves the body relatively quickly. Since tritium is almost always found as water, it goes directly into soft tissues and organs. The associated dose to these tissues is generally uniform and is dependent on the water content of the specific tissue.

III. Introduction Cooper Nuclear Station is located in Nemaha County in the southeast corner of Nebraska on the Missouri River. A portion of the site extends into Missouri. The reactor is an 805-megawatt (net electrical) boiling water reactor. Initial criticality was attained on February 21, 1974.

This report covers those analyses performed by Teledyne Brown Engineering (TBE) on samples collected in 2009.

6 H-7

A. Objectives of the Radiological Groundwater Protection Program (RGPP)

The long-term objectives of the RGPP are as follows:

1. Identify suitable locations to monitor and evaluate potential impacts from station operations before significant radiological impact to the environment and potential drinking water sources.
2. Understand the local hydrogeologic regime in the vicinity of the station and maintain up-to-date knowledge of flow patterns on the surface and shallow subsurface.
3. Perform routine water sampling and radiological analysis of water from selected locations.
4. Report new leaks, spills, or other detections with potential radiological significance to stakeholders in a timely manner.
5. Regularly assess analytical results to identify adverse trends.
6. Take necessary corrective actions to protect groundwater resources.

B. Implementation of the Objectives The objectives identified have been implemented at CNS as discussed below:

1. Cooper Nuclear Station will continue to perform routine sampling and radiological analysis of water from selected locations.
2. Cooper Nuclear Station has implemented new procedures to identify and report new leaks, spills, or other detections with potential radiological significance in a timely manner.
3. Cooper Nuclear Station staff assesses analytical results on an ongoing basis to identify adverse trends.

C. Program Description

1. Sample Collection Sample locations can be found in Appendix A, Table A-I and Map A-I.

Groundwater Samples of water are collected, managed, transported and analyzed in 7 H-8

accordance with approved procedures following regulatory methods.

Sample locations, sample collection frequencies and analytical frequencies are controlled in accordance with approved station procedures. Contractor and/or station personnel are trained in the collection, preservation management, and shipment of samples, as well as in documentation of sampling events. Analytical laboratories are subject to internal quality assurance programs, inter-laboratory cross-check programs, as well as nuclear industry audits. Station personnel review and evaluate all analytical data deliverables after initial review by the contractor.

Analytical data results are reviewed by both station personnel for adverse trends or changes to hydrogeologic conditions.

IV Program Description A. Sample Analysis This section describes the general analytical methodologies used by TBE to analyze the environmental samples for radioactivity for the CNS RGPP in 2009.

In order to achieve the stated objectives, the current program includes the following analyses:

1. Concentrations of gross alpha in groundwater.
2. Concentrations of tritium in groundwater.
3. Concentrations of strontium-89 and strontium-90 in groundwater.
4. Concentrations of iron-55 in groundwater.
5. Concentration of nickel-63 in groundwater.
6. Concentrations of gamma emitters in groundwater.

B. Data Interpretation The radiological data collected prior to CNS becoming operational were used as a baseline with which these operational data were compared. For the purpose of this report, CNS was considered operational at initial criticality. Several factors were important in the interpretation of the data:

8 S H-9

1. Lower Limit of Detection and Minimum Detectable Concentration The lower limit of detection (LLD) is specified by federal regulation as a minimum sensitivity value that must be achieved routinely by the analytical parameter.
2. Laboratory Measurements Uncertainty The estimated uncertainty in measurement of tritium in environmental samples is frequently on the order of 50% of the measurement value.

Statistically, the exact value of a measurement is expressed as a range with a stated level of confidence. The convention is to report results with a 95% level of confidence. The uncertainty comes from calibration standards, sample volume or weight measurements, sampling uncertainty and other factors. CNS reports the uncertainty of a measurement created by statistical process (counting error). Each result has two values calculated. CNS reports the result with plus or minus (+/-) the estimated sample standard deviation.

Analytical uncertainties are reported at the 95% confidence level in this

'report for reporting consistency with the REMP.

Gamma spectroscopy results for each type of sample were grouped as follows:

For groundwater 18 nuclides, Be-7, K-40, Mn-54, Co-58, Fe-59, Co-60, Zn-65, Zr-95, Ru-103, Ru-106, 1-131, Cs-134, Cs-137, Ba-140, Ce-141, Ce-144, Ra-226 and Th-228 were reported.

V. Results and Discussion A. Groundwater Results Gross Alpha Samples from 11 locations were analyzed for gross alpha (Table B-I, Appendix B). Gross alpha was detected at five locations. The concentrations ranged from 2.82 to 8.10 pCi/L.

Tritium Samples from 11 locations were analyzed for tritium activity (Table B-l, Appendix B). Tritium was detected at two locations. Tritium values 9 H-10

ranged from 238 to 1170 pCi/L. All values were below the CNS ODAM LLD of 2000 pCi/liter.

Strontium Samples from 11 locations were analyzed for strontium-89 and strontium-90 (Table B-i, Appendix B). Strontium-89 and strontium-90 were not detected at concentrations greater than the LLD.

Iron-55 Samples from 11 locations were analyzed for iron-55 (Table B-i, Appendix A). Iron-55 was not detected at concentrations greater than the LLD.

Nickel-63 Samples from 11 locations were analyzed for nickel-63 (Table B-i, Appendix B). Nickel-63 was not detected at concentrations greater than the LLD.

Gamma Emitters Naturally occurring potassium-40 was detected in five of 44 samples. The concentrations ranged from 35.4 to 88.7 pCi/liter. Thorium-228 was detected in four of 44 samples. The concentrations ranged from 4.09 to 9.52 pCi/liter. Ra-226 was detected on one sample at a concentration of 59.8 pCiL. No other gamma emitting nuclides were detected (Table B-i, Appendix B).

10 H-1I

APPENDIX A LOCATION DESIGNATION OF THE ANNUAL RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM REPORT (ARGPPR)

A-1 H-12

TABLE A- 1: Radiological Groundwater Protection Program - Sampling Locations, NEBRASKA PUBLIC POWER DISTRICT, Cooper Nuclear Station, 2009 Site Type ID Ground Water 1s Ground Water 2 Ground Water 3 Ground Water 4D Ground Water 4S Ground Water 5 Ground Water 6 Ground Water 7D Ground Water 7S Ground Water 8 Ground Water A-2 H-13

SaRvia VkWER PUMPmu 07 PARKING AREAS INRCA BUILDINGS E FENCE LINE PAVEMENT c:Qruptom~aoutwpSwCW6).dtf A-3 Ij H-14

APPENDIX B DATA TABLES B-1 H-15

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 1D DATE COLLECTED 03/02/09 05/05/09 08/05/09 11/10/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 8.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 3.E+01 SR-89 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 SR-90 L.T. 9.E-01 L.T. 4.E-01 L.T. 4.E-01 L.T. 8.E-01 FE-55 L.T. 2.E+02 L.T. 2.E+02 L.T. 1.E+02 L.T. 2.E+02 NI-63 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 5.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 K-40 8.46E+01 +/- 5.53E+01 L.T. 1.E+01 L.T. 5.E+00 L.T. 1.E+01 MN-54 L.T. 2.E+00 L.T. I.E+00 L.T. 7.E-01 L.T. 1.E+00 CO-58 L.T. 2.E+00 L.T. 1.E+00 L.T. I.E+00 L.T. 2.E+00 FE-59 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 CO-60 L.T. 1.E+00 L.T. 1.E+00 L.T. 6.E-01 L.T. I.E+00 ZN-65 L.T. 4.E+00 L.T. 2.E+00 L.T. I.E+00 L.T. 3.E+00 ZR-95 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-1 03 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 2.E+00 RU-106 L.T. 2.E+01 L.T. 1.E+01 L.T. 7.E+00 L.T. i.E+01 1-131 L.T. 7.E+01 L.T. 7.E+00 L.T. i.E+02 L.T. 1.E+01 CS-134 L.T. 2.E+00 L.T. I.E+00 L.T. 7.E-01 L.T. I.E+00 CS-137 L.T. 2.E+00 L.T. I.E+00 L.T. 7.E-01 L.T. 2.E+00 BA-140 L.T. 6.E+01 L.T. 1.E+01 L.T. 5.E+01 L.T. 2.E+01 CE-141 L.T. 6.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 4.E+00 CE-144 L.T. 1.E+01 L.T. 9.E+00 L.T. 6.E+00 L.T. 1.E+01 RA-226 L.T. 5.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 3.E+01

- TH-228 L.T. 3.E+00 L.T. 2.E+00 L.T. i.E+00 L.T. 3.E+00 H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER IS DATE COLLECTED 03/02/09 05/05/09 08/05/09 11/10/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 7.E+00 L.T. 5.E+01 L.T. 5.E+00 2.82E+00 +/- 1.85E+00 SR-89 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 4.E+00 SR-90 L.T. 5.E-01 L.T. 6.E-01 L.T. 5.E-01 L.T. 6.E-01 FE-55 L.T. 8.E+01 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 4.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 3.E+01 K-40 L.T. 1.E+01 L.T. 3.E+01 L.T. 1.E+01 L.T. 4.E+01 MN-54 L.T. I.E+00 L.T. 2.E+00 L.T. 6.E-01 L.T. 2.E+00 CO-58 L.T. 2.E+00 L.T. 2.E+00 L.T. 9.E-01 L.T. 3.E+00 FE-59 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 6.E+00 CO-60 L.T. 1.E+00 L.T. 2.E+00 L.T. 6.E-01 L.T. 2.E+00 ZN-65 L.T. 3.E+00 L.T. 3.E+00 L.T. I.E+00 L.T. 5.E+00 ZR-95 L.T. 3.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 5.E+00 RU-1 03 L.T. 2.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-1 06 L.T. 1.E+01 L.T. 2.E+01 L.T. 5.E+00 L.T. 2.E+01 1-131 L.T. 5.E+01 L.T. 1.E+01 L.T. 1.E+02 L.T. 2.E+01 CS-134 L.T. 1.E+00 L.T. 2.E+00 L.T. 6.E-01 L.T. 2.E+00 CS-137 L.T. 1.E+00 L.T. 2.E+00 L.T. 6.E-01 L.T. 2.E+00 BA-140 L.T. 4.E+01 L.T. 2.E+01 L.T. 6.E+01 L.T. 3.E+01 CE-141 L.T. 3.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 7.E+00 CE-144 L.T. 6.E+00 L.T. 1.E+01 L.T. 7.E+00 L.T. 2.E+01 RA-226 L.T. 3.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 6.E+01 TH-228 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 4.E+00 H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 2 DATE COLLECTED 03/04/09 05/06/09 08/11/09 11/09/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 7.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 2.E+00 SR-89 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 4.E+00 SR-90 L.T. 9.E-01 L.T. 5.E-01 L.T. 5.E-01 L.T. 6.E-01 FE-55 L.T. 1.E+02 L.T. 1.E+02 L.T. 1.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 4.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 2.E+01 K-40 L.T. 1.E+01 L.T. 2.E+01 L.T. 7.E+00 L.T. 2.E+01 MN-54 L.T. 2.E+00 L.T. 2.E+00 L.T. 9.E-01 L.T. 2.E+00 CO-58 L.T. 3.E+00 L.T. 2.E+00 L.T. I.E+00 L.T. 2.E+00 FE-59 L.T. 6.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 6.E+00 CO-60 L.T. 2.E+00 L.T. 2.E+00 L.T. I.E+00 L.T. 2.E+00 ZN-65 L.T. 3.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 4.E+00 ZR-95 L.T. 4.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 4.E+00 RU-103 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-106 L.T. 1.E+01 L.T. 2.E+01 L.T. 8.E+00 L.T. 2.E+01 1-131 L.T. 6.E+01 L.T. 1.E+01 L.T. 7.E+01 L.T. 2.E+01 CS-1 34 L.T. 1.E+00 L.T. 2.E+00 ( L.T. 8.E-01 L.T. 2.E+00 CS-1 37 L.T. 2.E+00 L.T. 2.E+00 L.T. 1.E+00 L.T. 2.E+00 BA-140 L.T. 5.E+01 L.T. 2.E+01 L.T. 5.E+01 L.T. 3.E+01 CE-141 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 CE-144 L.T. 1.E+01 L.T. 1.E+01 L.T. 7.E+00 L.T. 1.E+01 RA-226 L.T. 4.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 4.E+01 TH-228 L.T. 2.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00

z:i Oo H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02

B-1 NEBRASKA PUBUC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 3 DATE COLLECTED 03/04/09 05/06/09 08/11/09 11/09/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 6.E+00 L.T. 5.E+00 L.T. 5.E+00 3.91 E+00 +/- 2.00E+00 SR-89 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 SR-90 L.T. 6.E-01 L.T. 6.E-01 L.T. 7.E-01 L.T. 7.E-01 FE-55 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 5.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 2.E+01 K-40 L.T. 1.E+01 4.19E+01 +/- 2.63E+01 L.T. 2.E+01 L.T. 2.E+01 MN-54 L.T. I.E+00 L.T. 2.E+00 L.T. 8.E-01 L.T. 2.E+00 CO-58 L.T. 1.E+00 L.T. 2.E+00 L.T. 9.E-01 L.T. 3.E+00 FE-59 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 6.E+00 CO-60 L.T. I.E+00 L.T. 2.E+00 L.T. 7.E-01 L.T. 2.E+00 ZN-65 L.T. 2.E+00 L.T. 4.E+00 L.T. 1.E+00 L.T. 5.E+00 ZR-95 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 5.E+00 RU-103 L.T. 2.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-106 L.T. 1.E+01 L.T. 1.E+01 L.T. 6.E+00 L.T. 2.E+01 1-131 L.T. 5.E+01 L.T. 9.E+00 L.T. 6.E+01 L.T. 2.E+01 CS-134 L.T. 1.E+00 L.T. I.E+00 L.T. 6.E-01 L.T. 2.E+00 CS-1 37 L.T. i.E+00 L.T. 2.E+00 L.T. 7.E-01 L.T. 2.E+00 BA-140 L.T. 4.E+01 L.T. 2.E+01 L.T. 4.E+01 L.T. 3.E+01 CE-141 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 6.E+00 CE-144 L.T. 9.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 1.E+01 RA-226 L.T. 3.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 5.E+01 TH-228 L.T. 4.E+00 L.T. 3.E+00 L.T. i.E+00 L.T. 3.E+00 H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 ' L.T. 2.E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 4D DATE COLLECTED 03/04/09 05/06/09 08/11/09 11/09/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 7.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 3.E+00 SR-89 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 'L.T. 3.E+00 SR-90 L.T. 5.E-01 L.T. 3.E-01 L.T. 6.E-01 L.T. 8.E-01 FE-55 L.T. 8.E+01 L.T. 9.E+01 L.T. 2.E+02 L.T. 1.E+02 NI-63 L.T. 4.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 K-40 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 1.E+01 MN-54 L.T. 1.E+00 L.T. 1.E+00 L.T. 9.E-01 L.T. 2.E+00 CO-58 L.T. 2.E+00 L.T. 1.E+00 L.T. 1.E+00 L.T. 2.E+00 FE-59 L.T. 4.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 5.E+00 CO-60 L.T. 2.E+00 L.T. 1.E+00 L.T. 8.E-01 L.T. 2.E+00 ZN-65 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 ZR-95 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 4.E+00 RU-103 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-106 L.T. 1.E+01 L.T. 1.E+01 L.T. 7.E+00 L.T. 1.E+01 1-131 L.T. 5.E+01 L.T. 8.E+00 L.T. 7.E+01 L.T. 2.E+01 CS-134 L.T. 1.E+00 L.T. 1.E+00 L.T. 7.E-01 L.T. 2.E+00 CS-137 L.T. 1.E+00 L.T. 1.E+00 L.T. 8.E-01 L.T. 2.E+00 BA-140 L.T. 5.E+01 L.T. 1.E+01 L.T. 4.E+01 L.T. 3.E+01 CE-141 L.T. 5.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 5.E+00 CE-144 L.T. 1.E+01 L.T. 9.E+00 L.T. 6.E+00 L.T. 1.E+01 RA-226 L.T. 3.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 4.E+01 TH-228 L.T. 2.E+00 L.T. 3.E+00 4.09E+00 +/- 2.21E+00 L.T. 3.E+00 H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 4S DATE COLLECTED 03/04/09 05/06/09 08/11/09 11/09/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 SR-89 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 4.E+00 SR-90 L.T. 6.E-01 L.T. 7.E-01 L.T. 5.E-01 L.T. 5.E-01 FE-55 L.T. 1.E+02 L.T. 2.E+02 L.T. 1.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 4.E+00 L.T. 4,E+00 L.T. 4.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. l.E+01 L.T. 2.E+01 K-40 L.T. 2.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 4.E+01 MN-54 L.T. 2.E+00 L.T. 3.E+00 L.T. 8.E-01 L.T. 2.E+00 CO-58 L.T. 2.E+00 L.T. 2.E+00 L.T. 1.E+00 L.T. 2.E+00 FE-59 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 5.E+00 CO-60 L.T. 2.E+00 L.T. 4.E+00 L.T. 7.E-01 L.T. 2.E+00 ZN-65 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 4.E+00 ZR-95 L.T. 4.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 4.E+00 RU-i 03 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-106 L.T. 2.E+01 L.T. 2.E+01 L.T. 7.E+00 L.T. 2.E+01 1-131 L.T. 6.E+01 L.T. 9.E+00 L.T. 6.E+01 L.T. 2.E+01 CS-1 34 L.T. 6.E+01 L.T. 9.E+00 L.T. 6.E-01 L.T. 2.E+00 CS-137 L.T. 2.E+00 L.T. 1.E+00 L.T. 7.E-01 L.T. 2.E+00 BA-140 L.T. 6.E+00 L.T. I.E+01 L.T. 4.E+01 L.T. 3.E+01 CE-141 L.T. 6.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 6.E+00 CE-144 L.T. 6.E+01 L.T. 4.E+01 L.T. 6;E+00 L.T. 6.E+01 RA-226 L.T. 4.E+01 5.98E+01 +/- 3.67E+01 L.T. 2.E+01 L.T. 4.E+01 TH-228 L.T. 4.E+00 L.T. 3.E+00 L.T. 1.E+00 L.T. 3.E+00 I

HA I_' A Q7F*+-f9 + 1 AR*+fl 7 AR*÷n9 + I A4F-+-NV 0 '"A4-+l + 1 RAF-i+l9? 1 17F+fl' + 1 RI F+t 39 2

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 5 DATE COLLECTED 03/05/09 05/06/09 08/11/09 11/09/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 6.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+00 SR-89 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 SR-90 L.T. 9.E-01 L.T. 6.E-01 L.T. 5.E-01 L.T. 7.E-01 FE-55 L.T. 1.E+02 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 2.E+01 K-40 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 2.E+01 MN-54 L.T. I.E+00 L.T. 1.E+00 L.T. 1.E+00 L.T. 2.E+00 CO-58 L.T. 2.E+00 L.T. 2.E+00 L.T. 1.E+00 L.T. 2.E+00 FE-59 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 5.E+00 CO-60 L.T. 2.E+00 L.T. I.E+00 L.T. 8.E-01 L.T. 2.E+00 ZN-65 L.T. 2.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 4.E+00 ZR-95 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 RU-103 L.T. 2.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-106 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 2.E+01 1-131 L.T. 4.E+01 L.T. 9.E+00 L.T. 8.E+01 L.T. 2.E+01 CS-134 L.T. I.E+00 L.T. I.E+00 L.T. 9.E-01 L.T. 2.E+00 CS-137 L.T. I.E+00 L.T. 2.E+00 L.T. I.E+00 L.T. 2.E+00 BA-140 L.T. 4.E+01 L.T. 2.E+01 L.T. 5.E+01 L.T. 3.E+01 CE-141 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 6.E+00 CE-144 L.T. 7.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 2.E+01 RA-226 L.T. 2.E+o0 L.T. 3.E+01 L.T. 3.E+01 L.T. 4.E+01 TH-228 L.T. 2.E+00 L.T. 3.E+00 9.52E+00 +/- 2.94E+00 L.T. 4.E+00 H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 6 DATE COLLECTED 03/05/09 05/06/09 08/11/09 11/09/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 6.E+00 L.T. 4.E+00 L.T. 2.E+00 4.63E+00 +/- 2.08E+00 SR-89 L.T. 2.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 SR-90 L.T. 5.E-01 L.T. 6.E-01 L.T. 6.E-01 L.T. 7.E-01 FE-55 L.T. 2.E+02 L.T. 2.E+02 L.T. 1.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 3.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 2.E+01 K-40 L.T. 6.E+01 3.54E+01 +/- 2.24E+01 L.T. 2.E+01 L.T. 1.E+01 MN-54 L.T. 2.E+00 L.T. 2.E+00 L.T. 9.E-01 L.T. 2.E+00 CO-58 L.T. 2.E+00 L.T. 2.E+00 L.T. I.E+00 L.T. 2.E+00 FE-59 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 5.E+00 CO-60 L.T. 2.E+00 L.T. 2.E+00 L.T. 8.E-01 L.T. 2.E+00 ZN-65 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 3.E+00 ZR-95 L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-103 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-106 L.T. 1.E+01 L.T. 2.E+01 L.T. 8.E+00 L.T. 2.E+01 1-131 L.T. 5.E+01 L.T. 1.E+01 L.T. 8.E+01 L.T. 2.E+01 CS-134 L.T. 2.E+00 L.T. 2.E+00 L.T. 8.E-01 L.T. 2.E+00 CS-137 L.T. 2.E+00 L.T. 2.E+00 L.T. 9.E-01 L.T. 2.E+00 BA-140 L.T. 5.E+01 L.T. 2.E+01 L.T. 5.E+01 L.T. 3.E+01 CE-141 L.T. 4.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 CE-144 L.T. 9.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 1.E+01 RA-226 L.T. 4.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 5.E+01 TH-228 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 H-3 L.T. 2.E+02 2.38E+02 +/- 1.21E+02 3.35E+02 +/- 1.30E+02 2.47E+02 +/- 1.22E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 7D DATE COLLECTED 03/02/09 05/05/09 08/05/09 11/10/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 7.E+01 L.T. 4.E+01 L.T. 2.E+01 8.10E+00 +/- 3.30E+00 SR-89 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 4.E+00 SR-90 L.T. 6.E-01 L.T. 4.E-01 L.T. 6.E-01 L.T. 7.E-01 FE-55 L.T. 2.E+02 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+00 GAMMA SPECTRUM ANALYSIS:

0 BE-7 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 3.E+01 K-40 L.T. 2.E+01 4.90E+01 +/- 1.97E+01 L.T. 5.E+00 L.T. 2.E+01 MN-54 L.T. 9.E-01 L.T. 1.E+00 L.T. 7.E-01 L.T. 2.E+00 CO-58 L.T. 1.E+00 L.T. 1.E+00 L.T. I.E+00 L.T. 3.E+00 FE-59 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 6.E+00 CO-60 L.T. 8.E-01 L.T. I.E+00 L.T. 6.E-01 L.T. 2.E+00 ZN-65 L.T. 2.E+00 L.T. 2.E+00 L.T. I.E+00 L.T. 5.E+00 ZR-95 L.T. 2.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 5.E+00 RU-1 03 L.T. 2.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 3.E+00 RU-106 L.T. 9.E+00 L.T. I.E+01 L.T. 6.E+00 L.T. 2.E+01 1-131 L.T. 4.E+01 L.T. 8.E+00 L.T. 1.E+02 L.T. 2.E+01 CS-1 34 L.T. 8.E-01 L.T. 1.E+00 L.T. 6.E-01 L.T. 2.E+00 CS-1 37 L.T. 9.E-01 L.T. I.E+00 L.T. 7.E-01 L.T. 2.E+00 BA-140 L.T. 3.E+01 L.T. 1 .E+01 L.T. 5.E+01 L.T. 3.E+01 CE-141 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 6.E+00 CE-144 L.T. 5.E+00 L.T. 1.E+01 L.T. 6.E+00 L.T. 2.E+01 RA-226 L.T. 2.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 5.E+01 TH-228 L.T. 2.E+00 L.T. 2.E+00 L.T. 1.E+00 7.04E+00 +/- 3.68E+00

,'Q H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 7S DATE COLLECTED 03/02/09 05/05/09 08/05/09 11/10/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 6.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+00 SR-89 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 2.E+00 SR-90 L.T. 8.E-01 L.T. 6.E-01 L.T. 7.E-01 L.T. 8.E-01 FE-55 L.T. 1.E+02 L.T. 1.E+02 L.T. 2.E+02 L.T. 5.E+01 NI-63 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 3.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 1.E+01 L.T. 3.E+01 L.T. 1.E+01 L.T. 2.E+01 K-40 L.T. 9.E+00 L.T. 3.E+01 L.T. 6.E+00 L.T. 2.E+01 MN-54 L.T. 1.E+00 L.T. 2.E+00 L.T. 7.E-01 L.T. 2.E+00 CO-58 L.T. 1.E+00 L.T. 3.E+00 L.T. 9.E-01 L.T. 2.E+00 FE-59 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 5.E+00 CO-60 L.T. 9.E-01 L.T. 2.E+00 L.T. 6.E-01 L.T. 2.E+00 ZN-65 L.T. 2.E+00 L.T. 5.E+00 L.T. 2.E+00 L.T. 4.E+00 ZR-95 L.T. 2.E+00 L.T. 6.E+00 L.T. 2.E+00 L.T. 4.E+00 RU-103 L.T. 2.E+00 L.T. 3.E+00 L.T. I.E+00 L.T. 3.E+00 RU-106 L.T. 8.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 1-131 L.T. 3.E+01 L.T. 2.E+01 L.T. 9.E+01 L.T. 2.E+01 CS-1 34 L.T. 8.E-01 L.T. 2.E+00 L.T. 6.E-01 L.T. 2.E+00 CS-1 37 L.T. 9.E-01 L.T. 3.E+00 L.T. 6.E-01 L.T. 2.E+00 BA-140 L.T. 3.E+01 L.T. 3.E+01 L.T. 5.E+01 L.T. 3.E+01 CE-141 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 5.E+00 CE-144 L.T. 6.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 1.E+01 RA-226 L.T. 2.E+01 L.T. 5.E+01 L.T. 1.E+01 L.T. 4.E+01 TH-228 L.T. I.E+00 L.T. 6.E+00 L.T. I.E+00 6.21E+00 +/- 3.38E+00 H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+02

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 8 DATE COLLECTED 03/05/09 05/06/09 08/11/09 11/09/09 RADIOCHEMICAL ANALYSIS:

GR-A L.T. 7.E+00 L.T. 4.E+00 L.T. 2.E+00 3.21 E+00 +/- 2.04E+00 SR-89 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 3.E+00 SR-90 L.T. 6.E-01 L.T. 4.E-01 L.T. 5.E-01 L.T. 5.E-01 FE-55 L.T. 2.E+02 L.T. 1.E+02 L.T. 2.E+02 L.T. 2.E+02 NI-63 L.T. 4.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 4.E+00 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 7.E+00 K-40 8.87E+01 +/- 5.87E+01 L.T. 5.E+01 L.T. 9.E+00 L.T. 5.E+00 MN-54 L.T. I.E+00 L.T. 3.E+00 L.T. 1.E+00 L.T. 5.E-01 CO-58 L.T. 2.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 7.E-01 FE-59 L.T. 4.E+00 L.T. 8.E+00. L.T. 4.E+00 L.T. 1.E+00 CO-60 L.T. 2.E+00 L.T. 3.E+00 L.T. I.E+00 L.T. 6.E-01 ZN-65 L.T. 3.E+00 L.T. 5.E+00 L.T. 2.E+00 L.T. I.E+00 ZR-95 L.T. 4.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. I.E+00 RU-1 03 L.T. 3.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 9.E-01 RU-1 06 L.T. 1.E+01 L.T. 3.E+01 L.T. 1.E+01 L.T. 4.E+00 1-131 L.T. 6.E+01 L.T. 2.E+01 L.T. 7.E+01 L.T. 6.E+00 CS-1 34 L.T. I.E+00 L.T. 3.E+00 L.T. 9.E-01 L.T. 5.E-01 CS-137 L.T. 2.E+00 L.T. 3.E+00 L.T. I.E+00 L.T. 6.E-01 BA-140 L.T. 5.E+01 L.T. 3.E+01 L.T. 5.E+01 L.T. 9.E+00 CE-141 L.T. 5.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 2.E+00 CE-144 L.T. 1.E+01 L.T. 2.E+01 L.T. 8.E+00 L.T. 4.E+00 RA-226 L.T. 4.E+01 L.T. 7.E+01 L.T. 2.E+01 L.T. I.E+01 TH-228 L.T. 3.E+00 L.T. 6.E+00 L.T. 2.E+00 L.T. 2.E+00 H-3 L.T. 2.E+02 L.T. 2.E+02 L.T. 3.E+02 L.T. 2.E+02

APPENDIX I NON-ODAM REQUIRED SAMPLING, SUPPLEMENTARY STATIONS I-1

NEBRASKA PUBLICPOWER DISTRICT COOPER NUCLEAR STATION Non-ODAM Required Sampling, Supplementary Stations 2009 Annual Report January1, 2009 to December 31, 2009 Prepared by Teledyne Brown Engineering 2508 Quality Lane Knoxville, TN 37931-3133 1-2

TABLE OF CONTENTS

1. Introduction ........................................................................................................................ i............... 4 II. Sum mary and D iscussion ....................................................................................................... 5 A . A irborne Particulates ...................................................................................................... 5 B . A irborne Iodine ............................................................................................................ 5 C . Therm olum inescent D osim eters .................................................................................... 6 2

1-3

APPENDICES Appendix A: Non-ODAM Required Sampling Locations .................................................... A-i Table A-1: Non-ODAM Sampling Station Description, Sample Type and Sample Location, Nebraska Public Power District, Cooper Nuclear Station, 2009 ........... A-2 Appendix B: Data Tables of Non-ODAM Required Sampling Locations ........................... B-i Table B-1: Exposure Pathway - Airborne Air Particulate and Charcoal Filters..........B-2 Table B-2: Exposure Pathway - Airborne Composite Air Particulate Filters ..................... B-4 Table B-3: Exposure Pathway - Thermoluminescent Dosimetry ............................................ B-5 3

1-4

I Introduction This report contains a complete tabulation of data for non-ODAM required Sampling Stations collected during the period January through December 2009 for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) by Teledyne Brown Engineering - Environmental Services.

In assessing all the data gathered for this report, it was concluded that the operation of CNS had no adverse radiological impact on the environment, and there are no known active releases into the groundwater or surface water at Nebraska Public Power District.

4 1-5

II. Summary and Discussion of 2009 Analytical Results Data from the radiological analyses of environmental media collected during 2009 for non-ODAM required stations are tabulated and discussed below.

Radiological analyses of environmental media characteristically approach and frequently fall below the detection limits of state-of-the-art measurement methods. The "less than" values in the data tables were calculated from each specific analysis and are dependent on sample size, detector efficiency, length of counting time, chemical yield (when appropriate) and the radioactive decay factor from time of counting to time of collection.

Teledyne Brown Engineering's analytical methods meet or are below the Lower Limit of Detection (LLD) requirements given in Table 2 of the USNRC Branch Technical Position, Radiological Monitoring Acceptable Program (November 1979, Revision 1).

Appendix C contains a discussion of the LLD formulas.

The following is a discussion and summary of the results of the environmental measurements taken during the 2009 reporting period:

A. AirborneParticulates Gross beta activity was observed in 52 of the 52 samples collected during 2009. The average concentration was 0.023 pCi/m 3 with a range of 0.009 to 0.052 pCi/m 3. The results of the gross beta activities are presented in Table B-1. The gross beta activities for 2009 were comparable to levels measured in the previous several years. Prior to that period the gross beta activities were higher due to atmospheric nuclear weapons testing performed in other countries. The preoperational period of 1971 through 1974 averaged 0.098 pCi/m 3 gross beta.

Air particulate filters were collected weekly and composited by locations on a quarterly basis. They were analyzed by gamma ray spectroscopy. The results are presented in Table B-2. Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation, was measured in three of four composite samples. The location had an average Be-7 concentration of 0.160 pCi/mi3 with a range of 0.121 to 0.213 pCi/m 3.

During the preoperational period, beryllium-7 was measured at comparable levels. All other gamma emitters were below the detection limits.

B. AirborneIodine Charcoal cartridges used to collect airborne iodine were collected weekly and analyzed by gamma spectrometry for iodine- 131. The results are presented in Table B-1. All results were below the required lower limit of detection.

5 1-6

C. Thermoluminescent Dosimeters Thermoluminescent dosimeters (TLDs) determine environmental radiation doses and the results are presented in Table B-3. Ambient radiation was monitored at 26 non-ODAM required locations and collected quarterly. The quarterly average for the locations was 23.0 millirem/quarter and a range from 18.9 to 33.4 millirem/quarter. The preoperational period of 1971 through 1974 averaged 7.0 millirem/quarter. The data from year to year is in good agreement and indicates no adverse changes in radiation exposure to the population near the Cooper Nuclear Station.

6 1-7

APPENDIX A NON-ODAM REQUIRED SAMPLING STATIONS A-1 1-8

NON-ODAM SAMPLE STATION DESCRIPTION, SAMPLE TYPE AND SAMPLE LOCATION Sample Station (a) Sample Description - Type and Location No. 111 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: 10.8 miles west southwest and 1.3 miles west of Howe, Nebraska, NE 1/4, S13, T4N, RI3E, Nemaha County, Nebraska.

Lon. 095.84.165 W-Lat. 40.31.955 N NO Type: (1) Environmental Thermoluminescent Dosimetry N02 Type: (1) Environmental Thermoluminescent Dosimetry N03 Type: (1) Environmental Thermoluminescent Dosimetry N04 Type: (1) Environmental Thermoluminescent Dosimetry N05 Type: (1) Environmental Thermoluminescent Dosimetry N06 Type: (1) Environmental Thermoluminescent Dosimetry N07 Type: (1) Environmental Thermoluminescent Dosimetry N08 Type: (1) Environmental Thermoluminescent Dosimetry N09 Type: (1) Environmental Thermoluminescent Dosimetry N1O Type: (1) Environmental Thermoluminescent Dosimetry N 11 Type: (1) Environmental Thermoluminescent Dosimetry N12 Type: (1) Environmental Thermoluminescent Dosimetry N13 Type: (1) Environmental Thermoluminescent Dosimetry N14 Type: (1) Environmental Thermoluminescent Dosimetry N 15 Type: (1) Environmental Thermoluminescent Dosimetry A-2 1-9

Sample Station (a) Sample Description - Type and Location N16 Type: (1) Environmental Thermoluminescent Dosimetry N17 Type: (1) Environmental Thermoluminescent Dosimetry N18 Type: (1) Environmental Thermoluminescent Dosimetry N19 Type: (1) Environmental Thermoluminescent Dosimetry N20 Type: (1) Environmental Thermoluminescent Dosimetry N21 Type: (1) Environmental Thermoluminescent Dosimetry N22 Type: (1) Environmental Thermoluminescent Dosimetry N23 Type: (1) Environmental Thermoluminescent Dosimetry N24 Type: (1) Environmental Thermoluminescent Dosimetry N25 Type: (1) Environmental Thermoluminescent Dosimetry A-3 1-10

APPENDIX B DATA TABLES OF NON-ODAM REQUIRED SAMPLING LOCATIONS B-1 1-11

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 111 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

12/30/08 01/06/09 1.01 E+04 CU.FT. 2.36E-02 4.36E-03 L.T. 6.E-02 01/06/09 01/13/09 9.99E+03 CU.FT. 2.50E-02 4.38E-03 L.T. 5.E-02 01/13/09 01/20/09 1.OOE+04 CU.FT. 2.33E-02 4.20E-03 L.T. 6.E-02 01/20/09 01/27/09 1.OOE+04 CU.FT. 3.09E-02 4.84E-03 L.T. 2.E-02 01/27/09 02/03/09 1.01 E+04 CU.FT. 1.51 E-02 3.79E-03 L.T. 7.E-02 02/03/09 02/10/09 1.OOE+04 CU.FT. 3.09E-02 5.01 E-03 L.T. 2.E-02 02/10/09 02/17/09 1.01E+04 CU.FT. 2.87E-02 4.56E-03 L.T. 2.E-02 02/17/09 02/24/09 9.98E+03 CU.FT. 3.64E-02 5.14E-03 L.T. 6.E-02 02/24/09 03/03/09 1.02E+04 CU.FT. 2.80E-02 4.63E-03 L.T. 2.E-02 03/03/09 03/10/09 9.91 E+03 CU.FT. 2.35E-02 4.65E-03 L.T. 2.E-02 03/10/09 03/17/09 1.01E+04 CU.FT. 2.43E-02 4.45E-03 L.T. 3.E-02 03/17/09 03/24/09 1.01E+04 CU.FT. 1.77E-02 4.13E-03 L.T. 3.E-02 03/24/09 03/30/09 8.64E+03 CU.FT. 2.02E-02 4.44E-03 L.T. 4.E-02 03/30/09 04/07/09 1.15E+04 CU.FT. 1.58E-02 3.46E-03 L.T. 4.E-02 04/07/09 04/14/09 9.97E+03 CU.FT. 2.09E-02 4.06E-03 L.T. 6.E-02 04/14/09 04/21/09 1.03E+04 CU.FT. 1.48E-02 3.62E-03 L.T. 4.E-02 04/21/09 04/28/09 1.01 E+04 CU.FT. 1.52E-02 3.46E-03 L.T. 4.E-02 04/28/09 05/05/09 9.81 E+03 CU.FT. 1.48E-02 3.94E-03 L.T. 2.E-02 05/05/09 05/12/09 1.01 E+04 CU.FT. 1.35E-02 3.44E-03 L.T. 5.E-02 05/12/09 05/19/09, 1.OOE+04 CU.FT. 1.02E-02 2.97E-03 L.T. 3.E-02 05/19/09 05/26/09 1.01 E+04 CU.FT. 2.23E-02 4.23E-03 L.T. 4.E-02 05/26/09 06/02/09 1.02E+04 CU.FT. 1.12E-02 3.37E-03 L.T. 5.E-02 06/02/09 06/09/09 9.97E+03 CU.FT. 1.63E-02 4.09E-03 L.T. 4.E-02 06/09/09 06/16/09 1.OOE+04 CU.FT. 1.05E-02 3.38E-03 L.T. 3.E-02 06/16/09 06/23/09 9.96E+03 CU.FT. 9.30E-03 3.39E-03 L.T. 6.E-02 06/23/09 06/30/09 1.03E+04 CU.FT. 3.06E-02 6.44E-03 L.T. 5.E-02 t'Q

B-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 111 COLL TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.) (PCI/CU.M.)

06/30/09 07/07/09 9.85E+03 CU.FT. 1.85E-02 +/- 4.43E-03 L.T. 5.E-02 07/07/09 07/13/09 8.58E+03 CU.FT. 2.36E-02 +/- 4.82E-03 L.T. 7.E-02 07/13/09 07/21/09 1.16E+04 CU.FT. 1.26E-02 +/- 5.12E-03 L.T. 6.E-02 07/21/09 07/28/09 1.OOE+04 CU.FT. 1.54E-02 +/- 6.OOE-03 L.T. 5.E-02 07/28/09 08/03/09 8.73E+03 CU.FT. 9.92E-03 +/- 5.79E-03 L.T. 3.E-02 08/03/09 08/11/09 1.14E+04 CU.FT. 3.28E-02 +/- 5.86E-03 L.T. 5.E-02 08/11/09 08/18/09 1.02E+04 CU.FT. 1.74E-02 +/- 4.55E-03 L.T. 4.E-02 08/18/09 08/25/09 9.92E+03 CU. FT. 2.74E-02 +/- 5.68E-03 L.T. 3.E-02 08/25/09 09/01/09 1.01 E+04 CU.FT. 1.91 E-02 +/- 5.33E-03 L.T. 3.E-02 09/01/09 09/08/09 9.98E+03 CU.FT. 3.23E-02 +/- 6.31 E-03 L.T. 6.E-02 09/08/09 09/15/09 1.03E+04 CU.FT. 3.99E-02 +/- 5.44E-03 L.T. 4.E-02 09/15/09 09/22/09 9.86E+03 CU.FT. 2.30E-02 +/- 6.41 E-03 L.T. 5.E-02 09/22/09 09/29/09 1.01 E+04 CU.FT. 1.30E-02 +/- 5.44E-03 L.T. 7.E-02 09/29/09 10/06/09 1.OOE+04 CU.FT. 1.26E-02 +/- 3.49E-03 L.T. 1.E-02 10/06/09 10/13/09 1.OOE+04 CU.FT. 2.15E-02 +/- 5.59E-03 L.T. 6.E-02 10/13/09 10/20/09 1.01E+04 CU.FT. 1.91 E-02 +/- 5.54E-03 L.T. 4.E-02 10/20/09 10/27/09 1.OOE+04 CU.FT. 1.55E-02 +/- 3.98E-03 L.T. 4.E-02 10/27/09 11/03/09 1.02E+04 CU.FT. 1.64E-02 +/- 5.69E-03 L.T. 7.E-02 11/03/09 11/10/09 1.01 E+04 CU.FT. 2.65E-02 +/- 5.74E-03 L.T. 6.E-02 11/10/09 11/17/09 9.92E+03 CU.FT. 3.40E-02 +/- 6.16E-03 L.T. 2.E-03 11/17/09 11/24/09 1.03E+04 CU.FT. 3.80E-02 +/- 6.13E-03 L.T. 5.E-02 11/24/09 12/01/09 9.85E+03 CU.FT. 3.50E-02 +/- 6.40E-03 L.T. 5.E-02 12/01/09 12/08/09 1.02E+04 CU.FT. 2.47E-02 +/- 4.64E-03 L.T. 3.E-02 12/08/09 12/15/09 9.98E+03 CU.FT. 3.56E-02 +/- 6.56E-03 L.T. 6.E-02 12/15/09 12/22/09 1.01E+04 CU.FT. 5.24E-02 +/- 6.99E-03 L.T. 4.E-02 12/22/09 12/29/09 1.02E+04 CU.FT. 3.16E-02 +/- 5.97E-03 L.T. 6.E-02

B-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU.M.)

STATION NUMBER 111 DATE COLLECTED 12/30 - 03/30/09 03/30 - 06/30/09 06/30 - 09/29/09 09/29 - 12/29/09 GAMMA SPECTRUM ANALYSIS:

BE-7 1.46E-01 +/- 5.50E-02 L.T. 3.E-01 2.13E-01 +/- 1.11E-01 1.21E-01 +/- 5.26E-02 K-40 L.T. 5.E-02 L.T. 5.E-02 L.T. 4.E-02 L.T. 7.E-02 MN-54 L.T. 4.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 2.E-03 CO-58 L.T. 6.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. 4.E-03 FE-59 L.T. 2.E-02 L.T. 8.E-02 L.T. 3.E-02 L.T. 8.E-03 CO-60 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 2.E-03 ZN-65 L.T. 8.E-03 L.T. 1.E-02 L.T. 8.E-03 L.T. 7.E-03 ZR-95 L.T. 1.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 6.E-03 RU-1 03 L.T. 1.E-02 L.T. 7.E-02 L.T. 3.E-02 L.T. 8.E-03 RU-1 06 L.T. 3.E-02 L.T. 4.E-02 L.T. 3.E-02 L.T. 2.E-02 1-131 L.T. 6.E+00 L.T. 1.E+04 L.T. 2.E+02 L.T. I.E+00 CS-1 34 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 2.E-03 CS-1 37 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 BA-140 L.T. 1.E+00 L.T. 1.E+02 L.T. 1.E+01 L.T. 3.E-01 CE-141 L.T. 2.E-02 L.T. 1.E-01 L.T. 4.E-02 L.T. 1.E-02 CE-144 L.T. 1.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 RA-226 L.T. 4.E-02 L.T. 5.E-02 L.T. 5.E-02 L.T. 4.E-02 TH-228 L.T. 4.E-03 L.T. 5.E-03 L.T. 5.E-03 L.T. 3.E-03

B-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD COOPER NUCLEAR STATION 2009 Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01/01-03/31 04/01-06/30 07/01-09/30 10/01-01/01 - 1 S.D.

TLD 111 23.9 +/- 1.0 21.0 +/- 0.8 22.5 +/- 1.0 23.6 +/- 0.8 22.7 +/- 1.3 N01 26.5 +/- 0.0 19.9 +/- 0.2 23.3 +/- 0.3 22.2 +/- 0.4 23.0 +/- 2.7 N02 23.3 +/- 0.5 20.7 +/- 0.8 24.2 +/- 1.0 22.3 +/- 1.3 22.6 +/- 1.5 N03 23.0 +/- 1.1 21.7 +/- 0.6 33.4 +/- 4.6 21.9 +/- 0.4 25.0 +/- 5.6 N04 24.4 +/- 0.9 21.1 +/- 0.6 22.3 +/- 0.5 21.6 +/- 0.4 22.3 +/- 1.4 N05 23.1 +/- 1.3 19.4 +/- 0.3 26.1 +/- 2.8 21.2 +/- 1.2 22.5 +/- 2.9 N06 23.0 +/- 0.3 20.6 +/- 0.5 20.1 +/- 0.5 21.2 +/- 0.4 21.2 +/- 1.2 N07 24.8 +/- 0.3 32.1 +/- 2.4 22.9 +/- 0.5 22.6 +/- 0.5 25.6 +/- 4.4 N08 22.7 +/- 0.5 20.2 +/- 1.6 25.8 +/- 2.4 20.9 +/- 0.7 22.4 +/- 2.5 N09 23.7 +/- 0.4 21.0 +/- 0.3 23.2 +/- 0.4 22.4 +/- 0.7 22.6 +/- 1.2 N10 24.2 +/- 0.4 25.8 +/- 1.1 28.7 +/- 1.1 22.9 +/- 0.7 25.4 +/- 2.5 Nil 23.3 +/- 0.4 20.3 +/- 0.6 21.5 +/- 0.4 22.9 +/- 0.4 22.0 +/- 1.4 N12 25.8 +/- 0.8 20.2 +/- 0.7 23.0 +/- 0.1 22.9 +/- 0.4 23.0 +/- 2.3 N13 23.1 +/- 0.1 22.3 +/- 0.8 24.3 +/- 1.2 24.4 +/- 1.1 23.5 +/- 1.0 N14 24.1 +/- 0.3 25.2 +/- 0.9 23.1 +/- 0.5 22.8 +/- 0.7 23.8 +/- 1.1 N15 26.7 +/- 0.8 22.2 +/- 1.6 24.9 +/- 0.7 21.4 +/- 0.4 23.8 +/- 2.4 N16 26.5 +/- 0.6 22.2 +/- 0.7 24.0 +/- 0.8 22.2 +/- 0.5 23.7 +/- 2.0 N17 23.3 +/- 0.6 21.1 +/- 0.7 22.7 +/- 0.2 21.2 +/- 0.4 22.1 +/- 1.1 N18 21.7 +/- 0.5 23.7 +/- 1.0 20.9 +/- 0.5 21.5 +/- 0.8 22.0 +/- 1.2 N19 24.2 +/- 0.7 20.6 +/- 0.4 21.2 +/- 0.4 20.6 +/- 0.4 21.7 +/- 1.7 N20 26.4 +/- 0.3 22.7 +/- 0.1 23.0 +/- 0.6 23.9 +/- 1.3 24.0 +/- 1.7 N21 23.8 +/- 0.6 19.5 +/- 0.4 20.3 +/- 0.3 20.1 +/- 0.5 20.9 +/- 2.0 N22 25.3 +/- 0.5 (a) 21.9 +/- 1.4 20.2 +/- 0.3 22.5 +/- 2.6 (a) TLD N22 was identified as missing.

B-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD COOPER NUCLEAR STATION 2009 Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01/01-03/31 04/01-06/30 07/01-09/30 10/01-01/01 - 1 S.D.

N23 21.9 +/- 0.2 19.9 +/- 0.1 18.9 +/- 0.7 21.3 +/- 0.9 20.5 +/- 1.3 N24 26.3 +/- 0.6 25.4 +/- 0.9 (a) 23.6 +/- 0.8 25.1 +/- 1.4 N25 22.7 +/- 0.6 23.7 +/- 1.9 28.5 +/- 2.9 20.7 +/- 0.4 23.9 +/- 3.3 Average/Quarter 24.1 +/- 1.5 mrem/90 day! 22.1 +/- 2.8 mrem/90 day! 23.6 +/- 3.1 mrem/90 day: 22.0 +/- 1.1 mrem/90 days Average/Day 0.268 mrem/day 0.246 mrem/day 0.263 mrem/day 0.245 mrem/day Range (21.7-26.7) mrem/90 days (19.4-32.1) mrem/90 days (18.9-33.4) mrem/90 days (20.1-24.4) mrem/90 days Detection/Total 26/26 25/25 25/25 26/26 ON (a) TLD N24 was identified as missing.