E-mail from J. Richmond of USNRC to R. Conte of USNRC, Regarding Region I Daily Staff Notes 11-03-08 EB1 on Oc Rev 1
ML091690479
Person / Time
Site: Oyster Creek
Issue date: 11/03/2008
From: Richmond J
NRC Region 1
To: Conte R
NRC Region 1
References
FOIA/PA-2009-0070
Download: ML091690479 (3)


Text

Sarah Rich From: John Richmond ) Y-17 Sent: Monday, November 03, 2008 11:41 AM To: Richard Conte

Subject:

RE: EDO Daily Attachments: Region I Daily Staff Notes 11-03-08 EBlonOCrev-i .doc Importance: High see attached From: Richard Conte Sent: Monday, November 03, 2008 11:02 AM To: John Richmond; David Pelton; Ronald Bellamy

Subject:

John for your review.

Dave, can you line up Jim Davies for 400pm call today, he is out coatings expert.

Note this is draft so don't send it around yet, just to Jim.

Richard J. Conte Chief, Engineering Branch No. 1, DRS, Reg. I

[ (b)(6) -I Off. 610-337-5183

[ The information contained in this e-mail, including any attachment(s), is intended solely for use by the named addressee(s). If you are not the intended recipient, you are not authorized to disclose, copy, distribute or retain this message, in whole or in part, without written consent from the sender. This e-mail may also contain confidential or privileged information so consult with the sender before disclosing. If you have received this message in error, please notify the sender immediately. ]

Vt Inthi veOM was deeted in 111111M 1 aordance wit'jthe Freedom of Informlafto L Fowdo -2_07-1)y

Received: from R1CLSTRO0 .nrc.gov ([148.184.99.7]) by R1 MS01 .nrc.gov

([148.184.99.10]) with mapi; Mon, 3 Nov 2008 11:40:47 -0500 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: binary From: John Richmond <John. Richmond@nrc.gov>

To: Richard Conte <Richard.Conte@nrc.gov>

Importance: high Date: Mon, 3 Nov 2008 11:40:46 -0500

Subject:

RE: EDO Daily Thread-Topic: EDO Daily Thread-Index: Ack9zXSHvphzglPDRPSihLppjogigwABVcxg Message-ID:

<2856BC46F6A308418F033D973BBOEE72AA436328CD@R1 CLSTR01 .nrc.gov>

References:

<2856BC46F6A308418F033D973BBOEE72AA4387BC89@R1 CLSTR01 .nrc.gov>

In-Reply-To:

<2856BC46F6A308418F033D973BBOEE72AA4387BC89@R1 CLSTR01 .nrc.gov>

Accept-Language: en-US Content-Language: en-US X-MS-Has-Attach: yes X-MS-Exchange-Organization-SCL: -1 X-MS-TNEF-Correlator:

<2856BC46 F6A308418F033D973BBOEE72AA436328CD@R1 CLSTR01. nrc.gov>

MIME-Version: 1.0

DAILY STAFF NOTES REGION I November 3, 2008 On October 31, 2008, the Region I lead inspector for the Oyster Creek License Renewal Commitments Inspection was informed by Amergen that a pinhole carbuncle in one of the ten sand bed bays (drywell external), on the epoxy coating of the drywell steel liner, had been identified during a routine coating inspection. The pinhole carbuncle was described as a small blister, soft to the touch with a "bleed through" 6 inches long tear drop shaped surface stain, brownish in color, and dry to the touch. On November 2, the inspector entered the affected bay and an adjacent bay to independently assess the as found conditions. He observed a pinhole carbuncle about 1/4 inch in diameter, with evidence of a brownish stain line 6 inches long. He also observed 2 other smaller carbuncles in the same area, with evidence of discoloration, but no bleed through (no brownish stain). A repair work order is being prepared and repairs are scheduled to start on Nov. 4. Today, AmerGen will brief the NRC staff on the repair process, the cause determination approach, and extent of conditions for the other nine sand bed bays. This appears to be the only bay with any evident of blistering, based on tentative results of the coatings inspection process conducted by AmerGen.