At a Duke f WPower.,
A Duke Energy Company GARY R. PETERSON Vice President McGuire Nuclear Station Duke Power MG01 VP / 12700 Hagers Ferry Road Huntersville, NC 28078-9340 704 875 5333 704 875 4809 fax grpeters@duke-energy. corn May 12, 2004 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555
Subject:
McGuire Nuclear Station Docket Nos. 50-369 and 50-370 Annual Radiological Environmental Operating Report Pursuant to the requirements of Technical Specification 5.6.2, attached is the Annual Radiological Environmental Operating Report (AREOR) for the 2003 calendar year.
Questions regarding this report should be directed to Kay Crane, McGuire Regulatory Compliance at (704) 8754306.
Gary R. Peterson
e Cs www. duke-energy. corn
U. S. Nuclear Regulatory Commission May 12,2004 Page 2 Mr. J. J. Shea, Project Manager U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C. 20555 Mr. Luis Reyes U. S. Nuclear Regulatory Commission, Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30303 Division of Radiation Protection 3825 Barrett Drive Raleigh, N.C. 27609-7221 ANI Library Town Center, Suite 300S 29 South Main Street West Hartford, CT 06107-2445 Mr. Joe Brady Senior Resident Inspector McGuire Nuclear Site
R Duke ra-Power.
McGuire Nuclear Station Units 1 and 2 AREOR Annual Radiological Environmental Operating Report 2003
h Duke drPowerSM A Duke Energy Company ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT DUKE POWER COMPANY MCGUIRE NUCLEAR STATION Units 1 and 2 2003
TABLE OF CONTENTS 1.0 Executive Summary 2.0 Introduction 2.1 Site Description and Sample Locations 2.2 Scope and Requirements of the REMP 2.3 Statistical and Calculational Methodology.
2.3.1 Estimation of the Mean Value.
2.3.2 Lower Level of Detection and Minimum Detectable Activity 2.3.3 Trend Identification.
1-1 2-1 2-1 2-1 2-2 2-2 2-3 2-3 3.0 Interpretation of Results.
3.1 Airborne Radioiodine and Particulates 3.2 Drinking Water.
3.3 Surface Water 3.4 Milk.
3.5 Broadleaf Vegetation.
3.6 Food Products 3.7 Fish.
3.8 Shoreline Sediment 3.9 Direct Gamma Radiation 3.10 Land Use Census 3-1 3-2 3-5 3-7 3-9 3-10 3-11 3-12 3-15 3-18 3-20 4.0 Evaluation of Dose 4.1 Dose from Environmental Measurements 4.2 Estimated Dose from Releases 4.3 Comparison of Doses.
5.0 Quality Assurance 5.1 Sample Collection 5.2 Sample Analysis 5.3 Dosimetry Analysis 5.4 Laboratory Equipment Quality Assurance 5.4.1 Daily Quality Control 5.4.2 Calibration Verification 5.4.3 Batch Processing 5.5 Duke Power Intercomparison Program 5.6 Duke Power Audits 5.7 U.S. Nuclear Regulatory Commission Inspections 5.8 State of North Carolina Intercomparion Program 5.9 TLD Intercomparison Program 5.9.1 Nuclear Technology Services Intercomparison Program 5.9.2 State of North Carolina Intercomparison Program 5.9.3 Internal Crosscheck (Duke Power) 6.0 References 4-1 4-1 4-1 4-2 5-1 5-1 5-1 5-1 5-1 5-1 5-1 5-2 5-2 5-2 5-2 5-2 5-3 5-3 5-3 5-3 6-1 i
Appendices Appendix A: Environmental Sampling and Analysis Procedures A-I I. Change of Sampling Procedures A-2 II. Description of Analysis Procedures A-2 III. Change of Analysis Procedures.
A-3 IV. Sampling and Analysis Procedures A-3 A.1 Airborne Particulate and Radioiodine A-3 A.2 Drinking Water A-4 A.3 Surface Water.
A-4 A.4 Milk A-4 A.5 Broadleaf Vegetation A-4 A.6 Food Products.
A-5 A.7 Fish A-5 A.8 Shoreline Sediment A-5 A.9 Direct Gamma Radiation (TLD)
A-5 A.10 Annual Land Use Census A-6 V. Global Positioning System (GPS) Analysis A-6 Appendix B: Radiological Env. Monitoring Program - Summary of Results B-1 Air Particulate B-2 Air Radioiodine.
B-3 Drinking Water B-4 Surface Water B-5 Milk.
B-6 Broadleaf Vegetation B-7 Food Products.
B-8 Fish.
B-9 Shoreline Sediment B-10 Direct Gamma Radiation (TLD)
B-11 Appendix C: Sampling Deviations and Unavailable Analyses C-1 C. 1 Sampling Deviations C-2 C.2 Unavailable Analyses C-2 Appendix D: Analytical Deviations D-I Appendix E: Radiological Environmental Monitoring Program Results E-I LIST OF FIGURES 2.1-1 Sampling Locations Map (0.5 Mile Radius) 2-4 2.1-2 Sampling Locations Map (Ten Mile Radius) 2-5 3.1 Concentration of Gross Beta in Air Particulate 3-3 3.2 Concentration of Tritium in Drinking Water 3-5 3.3 Concentration of Tritium in Surface Water.
3-7 3.7-1 Concentration of Cs-137 in Fish 3-13 3.7-2 Concentration of Co-60 in Fish.
3-13 3.8-1 Concentration of Cs-137 in Shoreline Sediment.
3-15 3.8-2 Concentration of Co-60 in Shoreline Sediment 3-16 3.9 Direct Gamma Radiation (TLD) Results 3-18 3.10 2003 Land Use Census Map 3-21 LIST OF TABLES 2.1-A Radiological Monitoring Program Sampling Locations 2-6 2.1-B Radiological Monitoring Program Sampling Locations (TLD Sites) 2-7 ii
2.2-A Reporting Levels for Radioactivity Concentrations in Environmental Samples 2.2-B REM? Analysis Frequency 2.2-C Maximum Values for the Lower Limits of Detection 3.1-A Mean Concentrations of Radionuclides in Air Particulate 3.1-B Mean Concentrations of Air Radioiodine (I-131) 3.2 Mean Concentrations of Radionuclides in Drinking Water 3.3 Mean Concentrations of Tritium in Surface Water 3.4 Mean Concentrations of Cs-137 in Milk 3.5 Mean Concentrations of Cs-137 in Broadleaf Vegetation 3.6 Mean Concentrations of Cs-137 in Food Products 3.7 Mean Concentrations of Radionuclides in Fish 3.8 Mean Concentrations of Radionuclides in Shoreline Sediment 3.9 Direct Gamma Radiation (TLD) Results 3.10 Land Use Census Results 4.1-A 2003 Environmental and Effluent Dose Comparison 4.1-B Maximum Individual Dose for 2003 based on Environmental Measurements for McGuire Nuclear Station 5.0-A 2003 Duke Power Company Interlaboratory Comparison Program 5.0-B 2003 Environmental Dosimeter Cross-Check Results LIST OF ACRONYMS USED IN THIS TEXT (in alphabetical orider) 2-8 2-8 2-9 3-3 3-4 3-6 3-8 3-9 3-10 3-11 3-14 3-16 3-19 3-20 4-3 4-6 5-4 5-9 BW BiWeekly C
Control DEHNR Department of Environmental Health and Natural Resources DHEC Department of Health and Environmental Control EPA Environmental Protection Agency GI-LLI Gastrointestinal - Lower Large Intestine GPS Global Positioning System LLD Lower Limit of Detection M
Monthly MDA Minimum Detectable Activity MNS McGuire Nuclear Station mrem millirem NIST National Institute of Standards and Technology NRC Nuclear Regulatory Commission ODCM Offsite Dose Calculation Manual pCi/k picocurie per kilogram pCi/l picocurie per liter pCi/m3 picocurie per cubic meter PIP Problem Investigation Process Q
Quarterly REMP Radiological Environmental Monitoring Program SA Semiannually SLCs Selected Licensee Commitments SM Semimonthly TECH SPECs Technical Specifications TLD Thermoluminescent Dosimeter aCiwml microcurie per milliliter UFSAR Updated Final Safety Analysis Report W
Weekly iii
1.0 EXECUTIVE
SUMMARY
This Annual Radiological Environmental Operating Report describes the McGuire Nuclear Station Radiological Environmental Monitoring Program (REMP), and the program results for the calendar year 2003.
Included are the identification of sampling locations, descriptions of environmental sampling and analysis procedures, comparisons of present environmental radioactivity levels and pre-operational environmental data, comparisons of doses calculated from environmental measurements and effluent data, analysis of trends in environmental radiological data as potentially affected by station operations, and a summary of environmental radiological sampling results.
Quality assurance practices, sampling deviations, unavailable samples, and program changes are also discussed.
Sampling activities were conducted as prescribed by Selected Licensee Commitments (SLC's). Required analyses were performed and detection capabilities were met for all collected samples as required by SLC's. Eleven-hundred forty-one samples were analyzed comprising 1,628 test results in order to compile data for the 2003 report. Based on the annual land use census, the current number of sampling sites for McGuire Nuclear Station is sufficient.
Concentrations observed in the environment in 2003 for station related radionuclides were generally within the ranges of concentrations observed in the past. Inspection of data showed that radioactivity concentrations in surface water, drinking water, shoreline sediment and fish are higher than the activities reported for samples collected prior to the operation of the station. Measured concentrations were not higher than expected, and all positively identified measurements were within limits as specified in SLC's.
Additionally, environmental radiological monitoring data is consistent with effluents introduced into the environment W
by plant operations. The total body dose estimated to the maximum exposed member of the public as calculated by environmental sampling data, excluding TLD results, was 7.35E-2 mrem for 2003.
It is therefore concluded that station operations has had no significant i radiological impact on the health and safety of the public or the environment.
Vegetation Sampling Section I - Page I
2.0 INTRODUCTION
2.1 SITE DESCRIPTION AND SAMPLE LOCATIONS McGuire Nuclear Station (MNS) is located geographically near the center of a highly industrialized region of the Carolinas. The land is predominantly rural non-farm with a small amount of land being used to support beef cattle and farming. The McGuire site is in northwestern Mecklenburg County, North Carolina, 17 miles north-northwest of Charlotte, North Carolina. The site is bounded to the west by the Catawba River channel and to the north by 32,510 acre Lake Norman. Lake Norman is impounded by Duke Power Company's Cowans Ford Dam Hydroelectric Station. The tailwater of Cowans Ford Dam is the upper limit of Mountain Island Reservoir. Mountain Island Dam is located 15 miles downstream from the site.
Lookout Shoals Hydroelectric Station is at the upper reaches of Lake Norman. Marshall Steam Station is located on the western shore of Lake Norman, approximately 16 miles upstream from the site (reference 6.3).
MNS consists of two pressurized water reactors. Each reactor unit is essentially a mirror image of the other joined by an auxiliary building housing both separate and common equipment. Each unit was designed to produce approximately 1200 gross Megawatts of electricity.
Unit 1 achieved criticality August 8, 1981 and Unit 2 on May 8, 1983.
Figures 2.1-1 and 2.1-2 are maps depicting the Thermoluminescent Dosimeter (TLD) monitoring locations and the sampling locations. The location numbers shown on these maps correspond to those listed in Tables 2.1-A and 2.1-B. Figure 2.1-1 comprises all sample locations within 0.5 mile radius of MNS. Figure 2.1-2 comprises all sample locations within a ten mile radius of MNS.
2.2 SCOPE AND REQUIREMENTS OF THE REMP An environmental monitoring program has been in effect at McGuire Nuclear Station since 1977, four years prior to operation of Unit 1 in 1981. The preoperational program provides data on the existing environmental radioactivity levels for the site and vicinity which may be used to determine whether increases in environmental levels are attributable to the station.
The operational program provides surveillance and backup support of detailed effluent monitoring which is necessary to evaluate the significance, if any, of the contributions to the existing environmental radioactivity levels that result from station operation.
This monitoring program is based on NRC guidance as reflected in the Selected Licensee Commitments Manual, with regard to sample media, sampling locations, sampling frequency, and analytical sensitivity requirements.
Indicator and control locations were established for comparison purposes to distinguish radioactivity of station origin from natural or other "man-made" environmental radioactivity. The environmental monitoring program also verifies projected and anticipated radionuclide concentrations in the environment and related exposures Secion 2 - Page I
from releases of radionuclides from McGuire Nuclear Station. This program satisfies the requirements of Section IV.B.2 of Appendix I to 10CFR50 and provides surveillance of all appropriate critical exposure pathways to man and protects vital interests of the company, public, and state and federal agencies concerned with the environment.
Reporting levels for radioactivity found in environmental samples are listed in Table 2.2-A. Table 2.2-B lists the REMP analysis and frequency schedule.
The Annual Land Use Census, required by Selected Licensee Commitments, is performed to ensure that changes in the use of areas at or beyond the site boundary are identified and that modifications to the Radiological Environmental Monitoring Program are made if required by changes in land use. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10CFR50. Results are shown in Table 3.10.
Participation in an interlaboratory comparison program as required by Selected Licensee Commitments provides for independent checks on the precision and accuracy of measurements of radioactive material in REMP sample matrices. Such checks are performed as part of the quality assurance program for environmental monitoring in order to demonstrate that the results are valid for the purposes of Section IV.B.2 of Appendix I to 10CFR50. A summary of the results obtained as part of this comparison program are in Section 5 of this annual report.
2.3 STATISTICAL AND CALCULATIONAL METHODOLOGY 2.3.1 ESTIMATION OF THE MEAN VALUE There was one (1) basic statistical calculation performed on the raw data resulting from the environmental sample analysis program. The calculation involved the determination of the mean value for the indicator and the control samples for each sample medium. The mean is a widely used statistic.
This value was used in the reduction of the data generated by the sampling and analysis of the various media in the Radiological Environmental Monitoring Program. The following equation was used to estimate the mean (reference 6.8):
x xi S
X N
Where:
x = estimate of the mean, i =individual sample, N = total number of samples with a net activity (or concentration),
Xi = net activity (or concentration) for sample i.
NOTE: "Net activity (or concentration)" is the activity (or concentration) determined to be present in the sample.
No "Minimum Detectable Activity", "Lower Limit of Detection", "Less Than Level", or negative activities or concentrations are included in the calculation of the mean.
Section 2 - Page 2
2.3.2 LOWER LEVEL OF DETECTION AND MINIMUM DETECTABLE ACTIVITY The Lower Level of Detection (LLD) and Minimum Detectable Activity (MDA) are used throughout the Environmental Monitoring Program.
LLD - The LD, as defined in the Selected Licensee Commitments Manual is the smallest concentration of radioactive material in a sample that will yield a net count, above the system background, that will be detected with 95% probability with only 5%
probability of falsely concluding that a blank observation represents a "real" signal. The LLD is an a priori lower limit of detection. The actual LLD is dependent upon the standard deviation of the background counting rate, the counting efficiency, the sample size (mass or volume), the radiochemical yield, and the radioactive decay of the sample between sample collection and counting. The "required" LLD's for each sample medium and selected radionuclides are given in the Selected Licensee Commitments and are listed in Table 2.2-C.
MDA - The MDA may be thought of as an "actual" LLD for a particular sample measurement remembering that the MDA is calculated using a sample background instead of a system background.
2.3.3 TREND IDENTIFICATION One of the purposes of an environmental monitoring program is to determine if there is a buildup of radionuclides in the environment due to the operation of the nuclear station.
Visual inspection of tabular or graphical presentations of data (including preoperational) is used to determine if a trend exists.
A decrease in a particular radionuclide's concentration in an environmental medium does not indicate that reactor operations are removing radioactivity from the environment but that reactor operations are not adding that radionuclide to the environment in quantities exceeding the preoperational level and that the normal removal processes (radioactive decay, deposition, resuspension, etc.) are influencing the concentration.
Substantial increases or decreases in the amount of a particular radionuclide's release from the nuclear plant will greatly affect the resulting environmental levels; therefore, a knowledge of the release of a radionuclide from the nuclear plant is necessary to completely interpret the trends, or lack of trends, determined from the environmental data.
Some factors that may affect environmental levels of radionuclides include prevailing weather conditions (periods of drought, solar cycles or heavier than normal precipitation), construction in or around either the nuclear plant or the sampling location, and addition or deletion of other sources of radioactive materials (such as the Chernobyl accident). Some of these factors may be obvious while others are sometimes unknown.
Therefore, how trends are identified will include some judgment by plant personnel.
Section 2 - Page 3
I Figure 2.1-1 Section 2 - Page 4 r.C1
) I I I I I I I i
I I I I
I Il I j
I I
I Figure 2.1-2 McGuire Nuclear Station Sampling Locations Map (Ten Mile Radius)
Legend TLD Locations v
All Other locations O'er Public Roads Rail Roads
- ,/
County Boundary Incorporated Areas Water Awrowmte Icion of flatwes shon 0 1 2 3M Iznl vl e s Projectan NCSP NA027 Section 2 - Page 5 CG2-
TABLE 2.1-A MCGUIRE RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS
.Table 2.1-A Codes W
Weekly SM Semimonthly BW BiWeekly Q
Quarterly M
Monthiy SA Semiannually C
Control Site Location Description*
Air Rad.
Surface Drinking Shoreline Food Iish -ilk Broad N&
Par Water Water Sediment Product LeaVeg.
101 Nonh Mecklenburg Water Treatment Facility (3.31 mi E)
BW 119 Mt. Holly Municipal Water Supply (7.40 mi SSW)
BW 120 Site Boundary (0.46 mi NNE)
W M (b) 121 Site Boundary ( 0.47 mi NE)
W 125 Site Boundary ( 0.38 mi SW)
W M(b) 128 Discharge Canal Bridge (0.45 mi NE)
BW 129 Discharge Canal Entrance to Lake Norman ( 0.51 rni ENE)
SA SA 130 Hwy 73 Bridge Downstream (0.52 mi SW)
SA 131 Cowans Ford Dam (0.64 mi WNW)
BW 132 Charlotte Municipal Water Supply ( 11.1 mi SSE)
BW 133 Cornelius (6.23 mi ENE)
W 134 C East Lincoln Jr.High School (8.77 mi WNW)
W M
M(b) 135 C Plant Marshall Intake Canal (11.9 ml N )
BW 136 C Mooresville Municipal Water Supply ( 12.7 mi NNE)
BW 137 C Pinnacle Access Area ( 12.0 mi N )
SA SA 139 William Cook Dairy (2.49 mi E)
SM 141 C Lynch Dairy-Cows (14.8 mi WNW)
SM 188 5 mile radius Gardens ( 2.79 mi NNE)
M (a) 192 Peninsula (2.84 mi NNE)
W 193 SiteBoundary(0.19miN)
M(b) 194 East Lincoln County Water Supply (6.73 mi NNW)
BW 195 Fishing Access Road ( 0.19 mi N)
W (a) During Harvest Season (b) When Available
- GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.
Section 2 -Page 6
TABLE 2.1-B MCGUIRE RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS (TLD SITES)
Site Location Distance*
Sector Site Location Distance Sector HAMBRIGHT &
143 SITE BOUNDARY 0.27 miles NW 164 BEATrIES FORD ROAD 4.64 miles SSE HORSESHOE BEND 144 SITE BOUNDARY 0.46 miles NNE 165 BEACH ROAD 5.11 miles S
145 SIT BOUNDARY 0.47 miles NE 166 RIVERBEND FOSSIL STATION 5.25 miles SSW LUCIA RIVERBEND HWY/
146 SITE BOUNDARY 0.42 miles ENE 167 OLD FIREHOUSE 4.87 miles SW 147 SITE BOUNDARY 0.44 miles E
168 OLD PLANK ROAD BRIDGE 4.60 miles WSW 148 SITE BOUNDARY 0.46 miles ESE 169 GLOVER LANE 4.03 miles W
149 SITE BOUNDARY 0.50 miles SE 170 LfITLE EGYPT ROAD 4.32 miles WNW 151 SITE BOUNDARY 0.37 miles S
171 TRIANGLE ACE HARDWARE 3.95 miles NW WESTPORT COMMUNITY AT 152 SITE BOUNDARY 0.44 miles SSW 172 GOLF COURSE DRIVE 5.70 miles NNW KEISTLER STORE I 153 SITE BOUNDARY 0.47 miles SW 173 SI GLENWOOD ROAD 8.39 miles NNW EAST LINCOLN JR. HIGH 154 SITE BOUNDARY 0.45 miles W
174 SI SCHOOL 8.77 miles WNW 156 SITE BOUNDARY 0.44 miles WNW 175 C BOGER CITY 15.5 miles WNW BELMARROW ROAD /
189 SITE BOUNDARY 0.43 miles SSE 177 SI COULWOOD COMMUNITY 8.77 miles S
FLORIDA STEEL 190 SITE BOUNDARY 0.33 miles WSW 178 SI CORPORATION 9.32 miles SE MOORESVILLE WATER 157 THE POINTE/MOORESVILE 4.69 miles N
180 SI TREATMENTFACILITY 12.7 miles NNE OLD DAVIDSON WATER 158 BPTHEL CHURCH ROAD 4.33 miles NNE 181 SI TREATMENTFACILITY 7.02 miles NE 159 HENDERSON ROAD 4.98 miles NE 182 SI CORNELIUS I AIR SITE # 133 6.23 miles ENE ANCHORAGE MARINE MCGUIRE FISHING ACCESS 160 SHOWROOM 4.89 miles ENE 186 SI ROAD ON PENINSULA 0.24 miles NNW SAM FURR ROAD ENERGY EXPLORIUM I 161
& HWY 21 4.70 miles E
187 SI AIR SITE # 195 0.19 miles N
PENINSULA DEVELOPMENT I 162 RANSON ROAD 4.53 miles ESE 191 SI AIR SITE# 192 2.84 miles NNE 163 MCCOY ROAD 4.94 miles SE ::_:.
C = Control SI = Special Interest
- GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.
Section 2 - Page 7
TABLE 2.2-A REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES Analysis Water Air Particulates Fish Milk BroadLeaf (pCi/liter) or Gases
- (pCi/kg-wet)
(pCi/liter)
Vegetation (pCilm3)
_.__.__-(pCi/kg-wet)
H-3 20o,000(a),(b)
Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 I
Co-60 300 10,000 l
Zn-65 300 20,000 Zr-Nb-95 400 I-131 2
1 3
100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 300 (a) If no drinking water pathway exists, a value of 30,000 pCi/liter may be used.
(b) H-3 Reporting level not applicable to surface water TABLE 2.2-B REMP ANALYSIS FREQUENCY Sample Analysis Gamma
- Tritium Low Level Gross TLD Medium Schedule
- Isotopic, 1-131 Beta Air Radioiodine Weekly X
Air Weekly X
X Direct Radiation Quarterly X
Surface Monthly Composite X
Water Quarterly Composite X
l Drinking Monthly Composite X
(a)
X Water Quarterly Composite X
l Shoreline Sediment Semiannually X
Milk Semimonthly X
X l
Fish Semiannually X
Broadleaf Vegetation Monthl_
_)
X Food Products Monthly(b)
X (a) Low-level I-131 analysis will be performed if the dose calculated for the consumption of drinking water is > 1 mrem per year. An LLD of 1 pCi/liter will be required for this analysis.
(b) When Available Section 2 - Page 8
TABLE 2.2-C MAXIMUM VALUES FOR THE LOWER LIMITS OF DETECTION Analysis Water AirParticulates i
-Fish Milk BroadLeaf Sediment (pCi/liter) or Gases (pCilkg-wet)
(pCi/liter)
Vegetation (pCi/kg-dry)
(pCi/r 3 )
-_ I, -
(pCi/kg-wet)
Gross Beta 4
0.01 l
l H-3 2000 (a)
Mn-54 15 130 Fe-59 30 260 Co-58, 60 15 130 l
Zn-65 30 260 l
Zr-Nb-95 15 1-131 1(b) 0.07 1
60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-La-140 15 15 (a) If no drinking water pathway exists, a value of 3000 pCi/liter may be used.
(b) If no drinking water pathway exists, the LLD of gamma isotopic analysis may be used.
Section 2 - Page 9
3.0 INTERPRETATION OF RESULTS Review of 2003 REMP analysis results was performed to detect and identify changes in environmental levels as a result of station operation. The radionuclides with Selected Licensee Commitments reporting levels that indicate consistent detectable activity have been historically trended from preoperation to present. Analyses from 1977 - 1978 have been excluded since these results were much higher than the other preoperational years due to outside influences such as weapons testing. The preoperational analyses from 1981 were combined with the operational analyses from the latter part of 1981 and averaged to give one concentration for each radionuclide for that year.
The highest annual mean concentration of applicable Selected Licensee Commitments radionuclides from the indicator locations for each media type was used for trending purposes.
Trending was performed by comparing annual mean concentrations to historical results. Factors evaluated include the frequency of detection and the concentration in terms of the percent of the radionuclide's SLC reporting level (Table 2.2-A). All maximum percent of reporting level values were well below the 100% action level. The highest value reached during 2003 was 2.99% for drinking water tritium at the North Mecklenburg Water Treatment Facility (Location 101). Only Selected Licensee Commitments radionuclides were detected in 2003.
Changes in sample location, analytical technique, and presentation of results must be considered when reviewing for trends. Calculation of the annual mean concentrations has been performed differently over the history of the REMP. During 1979-1986, all net results (sample minus background) positive and negative, were included in the calculation of the mean. Only positive net activity results were used to calculate the mean for the other years. All negative values were replaced with a zero for calculational and graphical purposes to properly represent environmental conditions. A change in gamma spectroscopy analysis systems in 1987 ended a period when many measurements yielded detectable low-level activity for both indicator and control location samples. It is possible that the method the previous system used to estimate net activity may have been vulnerable to false-positive results.
This section includes tables and graphs containing the highest annual mean concentrations of any effluent related radionuclide detected since the change in analysis systems in 1987. Any zero concentrations used in tables or graphs represent activity measurements less than detectable levels.
Only the specific radionuclides that represent the highest dose contributors or demonstrate consistent detectable activity are shown graphically.
Data presented in Sections 3.1 through 3.9 support the conclusion that there was no significant increase in radioactivity in the environment around McGuire Nuclear Station due to station operations in 2003. Similarly, there was no significant increase in ambient background radiation levels in the surrounding areas. The 2003 land use census data, shown in Section 3.10, indicates that no program changes are required as a result of the census.
Section 3 - Page I
3.1 AIRBORNE RADIOIODINE AND PARTICULATES In 2003, 364 particulate and radioiodine samples were analyzed, 312 at six indicator locations and 52 at the control location. Particulate samples were analyzed weekly for gamma and gross beta. Radioiodine samples received a weekly gamma analysis.
Gross beta analyses indicated 1.50E-2 pCi/m3 at the location with the highest annual mean and 1.63E-2 pCi/m3 at the control location. No detectable gamma emitting particulate activity was found in any air particulate samples in 2003 and has not been found in environmental air samples since 1987.
No detectable I-131 activity in any environmental air radioiodine samples was found in 2003. K-40 and Be-7 that occur naturally were routinely detected in~
charcoal cartridges collected during the year.
Cs-137 activity was detected on one cartridge in 2003 from the control location. Cs-I 137 detection on the charcoal cartridge was determined in 1990 to be an active constituent of the charcoal.
A similar study was performed in 2001 again yielding this conclusion. Therefore, any Cs-137 activities were not used in any dose calculations in Section 4.0 of this report.
Figure 3.1 shows gross beta highest annual mean indicator and control location concentrations since 1985. There is no reporting level for gross beta. Table 3.1-A shows indicator and control location highest annual means for Cs-137 and gross beta. Since no gamma activity was detected in 2003, no reporting levels were approached.
Table 3.1-B gives indicator location highest annual means and control means since 1979 for I-131. Preoperational and ten year averages are also shown. No 1-131 activity has been detected since 1989.
Since no radionuclides other than Cs-137 detected at the control location were detected in 2003, no reporting levels were approached.
Section 3 -Page 2
Figure 3.1 pCim 3
Concentration of Gross Beta in Air Particulate 1.00OE-01 9.00E42 -_
8.00E-02 t
7.COE-02 S.OOE-02 5.E8-02
_-b___
4.OOE-02 3.00E.02 2.00E-02 1.OOE-4 -____
1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 4-- Indicator Location
-+--- Control Location I
There is no reporting levelfor Gross Beta in air particulate Table 3.1-A Mean Concentrations of Radionuclides in Air Particulate YEAR Cs-137 Indicator Cs-137 Control Beta Indicator Beta Control (pCi/m3 )
(pCi/n 3 )
(pCi/m3 )
(pCi/m3 )
1979*
4.40E-3 1.47E-3 1980*
6.70E-3 4.53E-3 1981*
6.16E-3 5.32E-3 1982*
3.82E-3 2.29E-3 1983*
2.93E-3 3.21E-3 1984 1.74E-3 8.29E-4 1985 1.86E-3 1.32E-3 2.44E-2 2.40E-2 1986 4.98E-3 3.03E-3 2.64E-2 2.52E-2 1987 1.071-2 7.91E-3 2.54E-2 2.59E-2 1988 0.OOE0 O.OOEO 7.49E-2 5.51E-2 1989 O.OOE0 0.OOEO 2.22E-2 2.14E-2 1990 O.OOE0 O.OOEO 2.58E-2 2.37E-2 1991 O.OOEO O.OOEO 2.16E-2 2.15E-2 1992 O.OOE0 O.OOEO 1.92E-2 2.02E-2 1993 0.OOE0 0.00E0 1.93E-2 2.04E-2 1994 O.OOEO O.OOE0 2.28E-2 2.02E-2 1995 O.OOE0 O.OOEO 3.02E-2 5.17E-2 1996 O.OOE0 O.OOEO 3.1 1E-2 5.49E-2 1997 0.OOE0 O.OOEO 2.34E-2 3.62E-2 1998 0.OOE0 0.OOE0 1.86E-2 2.66E-2 1999 0.00E0 0.OOE0 2.06E-2 3.47E-2 2000 O.OOEO O.OOE0 2.OOE-2 2.77E-2 2001 O.OOEO O.OOEO 1.79E-2 1.91E-2 Section 3 -Page 3 C6
Table 3.1-A continued YEAR Cs-137 Indicator [ Cs-137.Control Beta Indicator j Beta Control (pCi/m3 )
-I (pCinim3 (pCi/m3)
(pCim 3) I 2002 0.OOE0 0.OOE0 1.57E-2 1.72E-2 Average (1993 - 2002):
NOT APPLICABLE,1 -NOT APPLICABLE 2.20E-2 3.09E-2 2003 0.OOE0 0.OOE0 1.50E-2 1.63E-2 0.OOEO = no detectable measurements
- Radioiodines and Particulates analyzed together
- Gross Beta analysis not performed Table 3.1-B Mean Concentrations of Air Radioiodine (1-131)
Year Indicator Location (pCilm3)
Control Location (pCi/M3) 1979*
3.28E-3 1.04E-3 1980*
2.01E-3 1.10E-3 1981*
4.17E-3 6.27E-4 1982*
1.42E-3 2.48E-3 1983*
1.99E-3 2.01E-4 1984 3.17E-3 0.00E0 1985 3.15E-3 1.04E-3 1986 1.27E-2 6.10E-3 1987 1.07E-2 6.60E-3 1988 0.00E0 O.OOE0 1989 2.18E-2 0.00E0 1990 O.OOE0 O.OOE0 1991 0.00E0 O.OOE0 1992 O.OOEO O.OOE0 1993 O.OOE0 0.00E0 1994 0.00E0 O.OOEO 1995 0.OOE0 0.OOE0 1996 0.00E0 0.00E0 1997 O.OOEO O.OOEO 1998 O.OOE0 O.OOEO 1999 0.00E0 O.OOEO 2000 O.OOEO 0.OOE0 2001 O.OOEO 0.00E0 2002 0.00E0 O.OOE0 2003 O.OOE0 O.OOE0 O.OOEO = no detectable measurements
- Radioiodines and Particulates analyzed together.
Section 3 -Page 4
3.2 DRINKING WATER In 2003, 65 drinking water samples were analyzed for gross beta and gamma emitting radionuclides.
Fifty-two samples were from the four indicator locations and 13 from the control location. Tritium (H-3) analyses were performed on 20 composite samples, 16 at indicator locations and four at the control location.
No detectable gamma activity was found in drinking water samples in 2003 and has not been detected since 1987. Gross beta analyses indicated 1.81 pCi/l at the location with the highest annual mean and 1.52 pCi/l at the control location. Tritium was detected in 10 of the 16 indicator composite samples taken in 2003 with the highest annual mean resulting in only 2.99% of the reporting level. The dose for consumption of water was less than one mrem per year, historically and for 2003; therefore low-level iodine analysis is not required.
Figure 3.2 shows tritium highest annual mean indicator and control location concentrations with comparisons to 10% of the reporting level. Table 3.2 gives indicator location highest annual means and control means since 1979 for tritium and gross beta. There is no reporting level for gross beta.
Drinking water Location 101 was added to the sampling program in 1999. Figure 3.2 shows a slight increase beginning in that year.
Figure 3.2 pCi/lter Concentration of Tritium in Drinking Water ZOUU T 2000 I
I I
I I
I I
I 150 100 iNJ 0otA\\
0o-f--liA_
Ad I
I I
01 V
I
_t i~
I_
so l
1979 1981 1983 19v5 1987 1989 1991 1993 1995 19 97 1 999 2001 2003 l---
Indicator Location
+
Control Location 10% Reporting Level I Section 3 -Page 5 CCAI
Table 3.2 Mean Concentrations of Radionuclides in Drinking Water Gross Beta (pCpiA)
Tritium (pCi/l) 0
_YEAR Indicator Control Indicator Control i'_____
Location
-Location Location
-_Location 1979 2.40E0 2.03E0 1.65E2 1.50E2 1980 2.34E0 1.87E0 1.63E2 2.05E2 1981 2.79E0 2.41E0 1.88E2 1.78E2 1982 2.62E0 2.43EO 2A3E2 1.45E2 1983 1.80E0 1.87EO 2.65E2
.1.45E2 1984 2.78E0 1.81E0 5.77E2 2.45E2 1985 1.88E0 1.90E0 5.93E2 4.00E2 1986 2.13E0 2.15EO 1.14E3 4.37E2 1987 2.30E0 2.00E0 1.35E3 7.75E2 1988 2.00E0 2.00E0 9.92E2 7.11E2 1989 2.80E0 2.70E0 5.62E2 0.OOEO 1990 3.70E0 4.30E0 7.32E2 6.11E2 1991 2.40E0 2.50E0 5.22E2 O.OOEO 1992 2.OOEO 1.70EO 6.73E2 0.00E0 1993 2.80E0 2AOEO 0.00E0 O.OOEO 1994 2A7E0 2.90E0 O.00E0 O.OOEO 1995 4.20E0 3.30E0 3.58E2 0.00E0 1996 2.75E0 2.11EO 3.60E2 0.00E0 1997 2.70E0 2.24E0 2.90E2 0.OOEO 1998 2.75E0 2.33E0 2.68E2 0.OOEO 1999 2.48E0 2.17E0 5.49E2 O.OOEO 2000 2.66EO 1.99EO 5.04E2 0.OOEO 2001 2.48E0 2.19EO 6.98E2 0.OOEO 2002 2.47E0 2.08E0 5.64E2 0.OOEO 2003 1.81EO 1.52EO 3.51E2 0.00E0 O.OOEO =no detectable measurements Section 3-Page6
3.3 SURFACE WATER In 2003, 39 surface water samples were analyzed for gamma emitting radionuclides, 26 at the two indicator locations and 13 at the control location. Analyses for H-3 were performed on 12 samples, eight at indicator locations and four at the control location.
No detectable gamma activity was found in surface water samples in 2003 and has not been detected since 1988.
Tritium was detected in seven of the eight indicator composite samples taken in 2003. Tritium was not detected in any of the control location composite samples in 2003.
Figure 3.3 shows tritium highest annual mean indicator and control location concentrations.
Table 3.3 gives indicator and control location highest annual means since 1979 for tritium.
Figure 3.3 pCi/liter Concentration of Tritium in Surface Water 4500 4000-3500 0-3000 2500 1500 198 1
1 1
1 199
-1 2001 2003 1979 1981 1983 1985 1987 1989 1991 1993 1995 1997 1999 2001 2003 l--
Indicator Location Control Location There is no reporting level for tritium in surface water Section 3 -Page 7
_ 0o5:
Table 3.3 Mean Concentrations of Tritium in Surface Water YEAR 1H-3 Indicator (pCi/1)
.H-3 Control (pCi/1) 1979 1.85E2 1.66E2 1980 2.13E2 1.93E2 1981 1.75E2 1.70E2 1982 3.30E2 1.23E2 1983 5.75E2 3.67E2 1984 4.10E2 2.65E2 1985 7.33E2 O.OOEO 1986 2.33E3 6.13E2 1987 9.20E2 7.70E2 1988 9.40E2 O.OOEO 1989 8.22E2 O.OOEO 1990 6.77E2 O.OOEO 1991 7.53E2 O.OOEO 1992 8.13E2 O.OOEO 1993 6.85E2 O.OOEO 1994 O.OOEO O.OOEO 1995 3.15E2 O.OOEO 1996 8.08E2 O.OOEO 1997 4.85E2 O.OOEO 1998 3AOE2 O.OOEO 1999 5.60E2 O.OOEO 2000 6.22E2 O.OOEO 2001 6.98E2 O.OOEO 2002 5.65E2 O.OOEO 2003 3.91E2 O.OOEO O.OOEO =no detectable measurements Section 3 -Page 8
3.4 MILK In 2003, 58 milk samples were analyzed for low level I-131 and other gamma emitting radionuclides, 31 at the two indicator locations and 27 at the control location.
One indicator dairy ceased operation in February, 2004 leaving one indicator location and the control. A replacement dairy was not available.
No detectable activity was found in milk samples in 2003 other than naturally-occurring K-40. Cs-137 has not been detected in milk samples since 1990 and all other radionuclides have not been detected since 1987.
Table 3.4 gives indicator location highest annual means and control means since 1979 for Cs-137.
Since no activity was detected in 2003, no reporting levels were approached.
1 Table 3.4 Mean Concentrations of Cs-137 in Milk l
YEAR Cs-137 Indicator (pCi/l)
Cs-137 Control (pCi/1) l 1979 2.48E1 6.04EO 1980 1.72E1 4.13EO 1981 2.04E1 4.15EO 1982 1.21E1 5.20EO 1983 2.01E1 2.82EO 1984 1.48E1 2.56EO 1985 1.42E1 2.72EO 1986 3.74E0 3.45EO 1987 5.20E0 8.60EO 1988 3.40E0 2.90EO 1989 6.OOEO 5.60EO 1990 5.30E0 2.60EO 1991 O.OOEO O.OOEO 1992 O.OOEO O.OOEO 1993 O.OOEO O.OOEO 1994 O.OOEO O.OOEO 1995 O.OOEO O.OOEO 1996 O.OOEO O.OOEO 1997 O.OOEO O.OOEO 1998 0.00E0 0.OOEO 1999 O.OOEO O.OOEO 2000 O.OOEO O.OOEO 2001 O.OOEO O.OOEO 2002 O.OOEO O.OOEO 2003 0.OOEO O.OOEO O.OOEO = no detectable measurements Secion 3-Page9
3.5 BROADLEAF VEGETATION In 2003, 28 broadleaf vegetation samples were analyzed, 21 at the three indicator locations and seven at the control location.
No detectable activity was detected in any of the vegetation samples taken in 2003.
Cs-137 was last detected in 1998 in one vegetation sample. No other detectable gamma activity was found in vegetation samples in 1998 and no other radionuclides have been detected in vegetation samples since 1987.
Table 3.5 gives indicator and control location highest annual means since 1979 for Cs-137.
Table 3.5 Mean Concentrations of Cs-137 in Broadleaf Veietation YEAR Cs-137 Control (pCi/kg) 1979 2.19E1 1.93E1 1980 2.30E1 1.92E1 1981 3.04E1 2.02E1 1982 2.46E1 1.22E1 1983 9.07E0 7.85E0 1984 1.02E1 1.05El 1985 8.05E0 2.37E-2 1986 4.03E1 1.27E1 1987 2.20E1 1.70E1 1988 3.90E1 3.40E1 1989 9.60E1 O.OOEO 1990 4.00E1 O.OOEO 1991 3.30E1 O.OOEO 1992 4.90E1 O.OOEO 1993 1.60EI 0.OOEO 1994 O.OOEO O.OOEO 1995 O.OOEO O.OOEO 1996 0.OOEO 0.OOEO 1997 0.00E0 0.OOEO 1998 0.OOEO 2.69E1 1999
_.OOEO
-.OOEO 2000 O.OOEO O.OOEO 2001 0.00E0 0.OOEO 2002 O.OOEO O.OOEO 2003 O.OOEO O.OOEO O.OOEO =no deectable measurements Section 3-Page 1O
3.6 FOOD PRODUCTS In 2003, 12 food products (crops) samples were analyzed, all at one indicator location. There is no control location for this media.
No detectable activity has been detected in this media since 1987. Table 3.6 shows Cs-137 indicator highest annual means with preoperational data and ten year averages. Since no activity was detected in 2003, no reporting levels were approached.
Table 3.6 Mean Concentrations of Cs-137 in Food Products YEAR Cs-137Indicator(pCi/kg) 1979 2.19E1 1980 2.30E1 1981 3.04E1 1982 2.46E1 1983 9.07E0 1984 8.45E0 1985 7.99E0 1986 2.15E1 1987 2.90E1 1988 O.OOEO 1989 O.OOEO 1990 O.OOEO 1991 O.OOEO 1992 O.OOEO 1993 0.00E0 1994 O.OOEO 1995 O.OOEO 1996 O.OOE0 1997 O.OOE0 1998 O.OOE0 1999 O.OOE0 2001 O.OOE0 2003 0.OOEO 0.OOEO no detectable measurements Section 3-Page II
3.7 FISH In 2003, 12 fish samples were analyzed for gamma emitting radionuclides, six at the indicator location and six at the control location.
Figure 3.7-1 shows Cs-137 highest annual mean indicator and control location concentrations with comparisons to 5% of the reporting level. Figure 3.7-2 shows Co-60 highest annual mean indicator and control location concentrations also with comparisons to 5% of the reporting level.
Table 3.7 gives indicator location highest annual means since 1980 for all radionuclides detected since the analysis change in 1988. No indicator samples were analyzed in 1979.
Co-58 activity was not detected in 2003 in any of the six indicator samples. Cs-137 activity was detected in 2003 in two of the six indicator samples taken. Cs-137 was not detected in any of the six control location samples. All other radionuclides not shown in the table have demonstrated no detectable activity since 1986.
The highest annual mean for Cs-137 activity in an indicator sample resulted in only 1.53% of the reporting level. Cs-137 was not detected at the control location.
Section 3-Page 12
Figure 3.7-1 pCi/kg Concentration of Cs-137 in Fish 140 -
=
120 100 -
I 80 -
60 -
40
-I I
20 18 18 1
9 1980 1982 1984 1986 1988 1990 1992 1994 196 98 200 02 1996 1998 2000 2002 Il Indicator Location
+
Control Location 5% of Reporting Level I Figure 3.7-2 pCi/kg Concentration of Co-60 In Fish 0oo 0oo
$00 300 20 too o0 fP
=
IN A
1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 U-Indicator Location Control Location 5% of Reporting Level Section 3-Page 13
Table 3.7 Mean Concentrations of Radionuclides in Fish (PCi/k2)
-1'Co-58.
. YEAR Indicator '
.'Indicator'. '.
Indicator
-Indicator :,-
Indicator 1980
-1.97E1 8.36E0
-2.25E1
-2.70E1
-4.13E0 1981
-2.71E0
-2.98E0
-2.65E0
-1.99E0 1.80E1 1982
-3.83E0 8.16E0
-4.34E-1
-8.22E-1 2.69E1 1983
-2.60E0 2.60E1 1.11El
-1.32E0 6.03E1 1984 3.61E0 1.45E2 2.82E1 3.11E 4.38E1 1985 2.53E-1 7.19E0 1.72E1
-1.56E0 1.86E1 1986 1.03E0 3.17E1 2.96E1 1.67E1 3.49E1 1987 O.OOE0 2.71E2 1.25E2 2.60E1 5.1OEl 1988 1.20E1 7.70E1 O.OOEO 2.70E1 3.60E1 1989 9.00E1 4.05E2 2.99E2 l.1OE1 350E1 1990 O.OOE0 5.60E1 4.10E1 O.OOEO 3.30E1 1991 6.20E0 1.40E1 6.50E1 5.90E0 2.60E1 1992 O.OOEO O.OOE0 O.OOEO O.OOEO 2.90E1 1993 O.OOE0 8.20E1 1.30E1 O.OOE0 1.60E1 1994 O.OOEO O.OOEO O.OOEO O.OOE0 3.10E1 1995 O.OOE0 O.OOE0 O.OOEO O.OOE0 2.70E1 1996 O.OOE0 O.OOE0 O.OOEO O.OOE0 2.78E1 1997 0.00E0 0.OOEO O.00E30 0.OOEO 1.62E1 1998 O.OOEO O.OOEO O.OOE0 O.OOE0 3.21E1 1999 O.OOEO 3.53E1 O.OOEO O.OOE0 2.10E1 2000 0.OOEO 4.28E1 0.00E0 0.00E0 2.34E1 2001 O.OOE0 1.32E1 O.OOE0 O.OOEO 3.04E1 2002 0.00E0 0.OOEO 0.00E0 0.00E0 2.33E1 2003 0.OOEO
~
- 0.00E 0.OOEO 0.OOEO
-3.05E1I 0.00E0 = no detectable measurements All negative values have been replaced with zeros for calculational purposes Section 3-Page 14
3.8 SHORELINE SEDIMENT In 2003, six shoreline sediment samples were analyzed, four from two indicator locations and two at the control location.
Figure 3.8-1 shows Cs-137 highest annual mean indicator and control location concentrations since 1979.
Figure 3.8-2 shows Co-60 highest annual mean indicator and control location concentrations since 1979.
Table 3.8 gives indicator location highest annual means since 1979 for all radionuclides detected since the analysis change in 1988. There is no reporting level for shoreline sediment.
Figure 3.8-1 pCIkg Concentration of Cs-137 in Shoreline Sediment 500 450 400 350 300 250 200 150 100 50 0
I I
I I
I L/o
-1 l 1 I I I i 2 1 1..
1979 1981 1983 1985 1987 1989 1991 1993 1995 1997 1999 2001 2003 Il-d-Indicator Location
+ Control Location I
- -Iniao-oain--CnrlLcto There is no reporting levelfor Cs-137 in shoreline sediment Section 3-Pagel5 C.(7
Figure 3.8-2 pC/kg Concentration of Co-SO In Shoreline Sediment 400 350 250__
200 150 100 50--
50
_-I 0
i td<[i
-I ~A-1 t_*
1981 1983 1985 1987 1989 1991 1993 1995 1997 1999 2001 2003 Indicator Location Control Location There is no reporting levelfor Co-60 in shoreline sediment Table 3.8 Mean Concentrations of Radionuclides in Shoreline Sediment (Ci/kQ)
Mn-54 Co-58 Co-60 Cs-134 Cs-137 YEAR Indicator Indicator Indicator Indicator Indicator 1979
-1.07E1 2.25E1
-6.50E0 O.OOEO 1.20E1 1980 1.06E1
-8.74E0 2.36E1
-3.53E0 1.44E1 1981 2.13E1 1.20E1 8.21E0 3.97E1 3.36E1 1982 5.38E1 1.66E1
-1.69E0 7.67E1 4.40E1 1983 4.40E0 3.43E1 2.12E1 7.65E1 8.02E1 1984 1.19E1 7.11E1 3.04E1 3.34E1 9.13E1 1985 4.77E0 1.46E1 9.20E0 2.02E1 1.61E2 1986 1.37E1 1.02E1 1.16E1 6.35E1 1.53E2 1987 O.OOE0 1.06E2 2.10E1 4.20E1 1.65E2 1988 6.50E0 9.20E1 1.20E1 9.10E0 2.66E2 1989 2.90E1 3.80E1 2.90E1 5.30E1 6.50E1 1990 3.80E1 2.70E1 1.68E2 O.OOEO 6.10E1 1991 2.80E1 5.30E1 1.31E2 O.OOEO 1.03E2 1992 9.40E0 O.OOEO 5.10E1 9.20E0 8.60E1 1993 0.OOE0 2.20E1 8.60E1 O.OOE0 9.30E1 1994 4.10E1 0.OOE0 O.OOE0 O.OOE0 8.00E1 1995 1.70E1 0.OOE0 2.30E1 0.OOE0 1.38E2 1996 2.90E1 1.78E1 3.50E1 O.OOE0 1.47E2 1997 O.OOEO O.OOEO 1.11E2 3.1OE1 1.36E2 1998 O.OOE0 O.OOEO 5.21E1 O.OOE0 9.97E1 1999 O.OOEO 2.47E1 8.49E1 O.OOEO 6.51E1 2000 O.OOEO 3.04E1 O.OOEO O.OOE0 1.08E2 Section 3 - Page 16
Table 3.8 continued Mn-54
-YEAR Indicator Indicator Indicator Indicator Indicator 2001 O.OOEO O.OOEO O.OOEO 0.00E0 2.77E1 2002 2.24E1 O.OOEO O.OOEO 0.OOEO 1.59E2 2003 O.OOEO (XOOEO O.OOEO O.OOEO 1.1 1E2 Section 3 -Page 17
3.9 DIRECT GAMMA RADIATION In 2003, 161 TLDs were analyzed, 157 at indicator locations, four at the control location. TLDs are collected and analyzed quarterly.
The highest annual mean exposure for an indicator location was 108.8 milliroentgen. The annual mean exposure for the control location was 92.0 milliroentgen.
Figure 3.9 and Table 3.9 show TLD inner ring (site boundary), outer ring (4-5 miles), and control location annual averages in milliroentgen per year. Preoperational data and ten year rolling averages are also given. As shown in the graph, inner and outer ring averages historically compare closely, with control data somewhat higher. Inner and outer ring averages comprise a number of data points with the control average representing only one location.
The calculated total body dose from gaseous effluents for 2003 was 7.43E-1 millirem, which is 1.10% of the average inner ring TLD values. Therefore, it can be concluded that discharges from the plant had very little impact on the measured TLD values.
Figure 3.9 mR"lr Direct Gamma Radiation (TLD) Results 200 -
180 160 -
140 120 _
100 -
80 FL 60 -
40 20 0_
1979 1981 1983 1985 1987 1989 1991 1993 1995 1997 1999 2001 200 Inner Ring Outer Ring Control There is no reporting levelfor Direct Radiation (TLD)
Section 3 - Page 18
Table 3.9 Direct Ganmma Radiation (TLD) Results YEAR Inner Ring Average Outer Ring Average Control
-(mR/yr)
'(mR/yr)
(mR/yr) 1979 7.91E1 8.82E1 8.32E1 1980 7.54E1*
8.29E1*
1.05E2 1981 l.OlE2 9.31E1 1.05E2 1982 8.95E1 8.97E1 1.10E2 1983 1.16E2 1.14E2 1.30E2 1984 7.85E1 7.83E1 9.02E1 1985 9.54E1 9.69E1 1.27E2 1986 8.91E1 9.35E1 M.lOE2 1987 7.58E1 7.71E1 1.23E2 1988 6.03E1 6.42E1 5.48E1 1989 5.37E1 5.30E1 7.55E1 1990 4.34E1 4.78E1 6.25E1 1991 5.14E1 5.59E1 6.80E1 1992 5.65E1 5.55E1 7.60E1 1993 5.61E1 5.71E1 7.20E1 1994 6.40E1 6.93E1 9.55E1 1995 8.36E1 8.25E1 1.08E2 1996 7.18E1 7.02E1 9.88E1 1997 6.22E1 6.68E1 9.45E1 1998 6.59E1 6.32E1 8.69E1 1999 6.23E1 6.05E1 8.96E1 2000 6.50E1 6.08E1 8.97E1 2001 6.51E1 6.22E1 9.33E1 2002 6.57E1 6.43E1 9.48E1 Average (1993-2002) 6.62E1 6.57E1 9.23E1 2003 6.74E1 6.45E1 9.20E1
- Values are based on two quarters due to change in TLD locations.
Section 3-Page 19
3.10 LAND USE CENSUS The land use census was conducted June 2 - June 4, 2003 and August 19, 2003 as required by SLC 16.11.14. Table 3.10 summarizes census results. A map indicating identified locations is shown in Figure 3.10.
During the 2003 census, no new or closer irrigated gardens were identified.
The nearest residence is located in the East sector at 0.48 miles. No program changes were required as a result of the 2003 land use census.
Table 3.10 McGuire 2003 Land Use Census Results Sector Distance Sector Distance (Miles).
(Miles)
Nearest Residence 2.56 Nearest Residence 1.45 N
Nearest Garden 4.91 S
Nearest Garden 3.21 Nearest Milk Animal Nearest Milk Animal Nearest Meat Animal Nearest Meat Animal (Cow) 2.98 Nearest Residence 1.23 Nearest Residence 2.56 NNE Nearest Garden 2.35 SSW Nearest Garden 2.94 Nearest Milk Animal Nearest Milk Animal Nearest Meat Animal Nearest Meat Animal Nearest Residence 1.21 Nearest Residence 1.85 NE Nearest Garden 2.18 sw Nearest Garden 4.41 Nearest Milk Animal Nearest Milk Animal Nearest Meat Animal Nearest Meat Animal (Cow) 2.57 Nearest Residence 0.58 Nearest Residence 1.01 ENE Nearest Garden (irrigated) 2.54 Wsw Nearest Garden 1.30 Nearest Milk Animal Nearest Milk Animal Nearest Meat Animal (Cow) 3.95 Nearest Meat Animal (Cow) 3.92 Nearest Residence 0.48 Nearest Residence 1.15 E
Nearest Garden 0.48 w
Nearest Garden 1.15 Nearest Milk Animal (Cow) 2.48 Nearest Milk Animal Nearest Meat Animal Nearest Meat Animal (Cow) 3.52 Nearest Residence 0.76 Nearest Residence 0.88 ESE Nearest Garden 1.10 WNW Nearest Garden 2.47 Nearest Milk Animal Nearest Milk Animal Nearest Meat Animal (Cow) 1.30 Nearest Meat Animal Nearest Residence 0.67 Nearest Residence 0.95 SE Nearest Garden 1.18 NW Nearest Garden 1.68 Nearest Milk Animal Nearest Milk Animal Nearest Meat Animal (Cow) 4.56 Nearest Meat Animal (Cow) 3.86 Nearest Residence 1.06 Nearest Residence 1.48 SSE Nearest Garden 2.18 NNW Nearest Garden (irrigated) 1.69 Nearest Milk Animal Nearest Milk Animal Nearest Meat Animal (Cow) 1A8 Nearest Meat Animal (Cow) 3.81
"-" indicates no occurrences within the 5 mile radius Section 3 -Page 20
I Figure 3.10 Section 3 -Page 21 Cv;l
4.0 EVALUATION OF DOSE 4.1 DOSE FROM ENVIRONMENTAL MEASUREMENTS Annual doses to maximum exposed individuals were estimated based on measured concentrations of radionuclides in 2003 MNS REMP samples. The primary purpose of estimating doses based on sample results is to allow comparison to effluent program dose estimates.
Doses based on sample results were calculated using the methodology and data presented in NRC Regulatory Guide 1.109. Measured radionuclide concentrations, averaged over the entire year for a specific radionuclide, indicator location and sample type, were used to calculate REMP-based doses.
Where applicable, average background concentration at the corresponding control location was subtracted.
Regulatory Guide 1.109 consumption rates for the maximum exposed individual were used in the calculations. When the guide listed "NO DATA" as the dose factor for a given radionuclide and organ, a dose factor of zero was assumed.
Maximum dose estimates (Highest Annual Mean Concentration) based on drinking water, fish, and shoreline sediment sample results are reported in Table 4.1-A. The individual critical population and pathway dose calculations are reported in Table 4.1-B.
REMP-based dose estimates are not reported for airborne radioiodine, airborne particulate, milk, or broadleaf vegetation sample types because no radionuclides other than naturally occurring K40 and Be-7 were detected in the samples. Dose estimates are not reported for surface water because sampled surface water is not considered to be a potable drinking water source. Exposure estimates based upon REMP TLD results are discussed in Section 3.9.
The maximum environmental organ dose estimate for any single sample type (other than direct radiation from gaseous effluents) collected during 2003 was 7.33E-2 mrem to the maximum exposed teen liver from fish.
4.2 ESTIMATED DOSE FROM RELEASES Throughout the year, dose estimates were calculated based on actual 2003 liquid and gaseous effluent release data. Effluent-based dose estimates were calculated using the RETDAS computer program which employs methodology and data presented in NRC Regulatory Guide 1.109. The 2003 MNS Annual Radioactive Effluent Release Report (reference 6.6) included calendar year dose estimates for the location with the highest individual organ dose from liquid and gaseous effluent releases. These reported doses are shown in Table 4.1-A along with the corresponding REMP-based dose estimates.
Section 4 - Page I
The effluent-based liquid release doses are summations of the dose contributions from the drinking water, fish, and shoreline pathways. The effluent-based gaseous release doses report noble gas exposure separately from iodine, particulate, and tritium exposure. For noble gas exposure there is no critical age group; as the maximum exposed individuals are assumed to receive the same doses, regardless of their age group. For iodine, particulate, and tritium exposure the effluent-based gaseous release doses are summations of the dose contributors from ground/plane, inhalation, milk and vegetation pathways.
4.3 COMPARISON OF DOSES The environmental and effluent dose estimates given in Table 4.1-A agree reasonably well. The similarity of the doses indicate that the radioactivity levels in the environment do not differ significantly from those expected based on effluent measurements and modeling of the environmental exposure pathways. This indicates that effluent program dose estimates are both valid and reasonably conservative.
There are some differences in how effluent and environmental doses are calculated that affect the comparison. Doses calculated from environmental data are conservative because they are based on a mean that includes only samples with a net positive activity versus a mean that includes all sample results (i.e. zero results are not included in the mean). Also, airborne tritium is not measured in environmental samples but is used to calculate effluent doses.
In calculations based on liquid release pathways, drinking water and fish consumption were the predominant dose pathways based on environmental and effluent data. The maximum total organ dose based on 2003 environmental sample results was 1.03E-1 mrem to the child liver. The maximum total organ dose of 8.59E-2 mrem for liquid effluent-based estimates was to the child liver.
No environmental doses resulted from the gaseous pathway in 2003 because broadleaf vegetation, milk, and airborne radioiodines and particulates indicated no activity. The gaseous effluent dose is due to tritium on broadleaf vegetation.
Noble gas samples are not collected as part of the REMP, preventing an analogous comparison of effluent-based noble gas exposure estimates.
The doses calculated do not exceed the 40CFR190 dose commitment limits for members of the public. Doses to members of the public attributable to the operation of MNS are being maintained well within regulatory limits.
Section 4 - Page 2
TABLE 4.1-A Page 1 of 3 MCGUIRE NUCLEAR STATION 2003 ENVIRONMENTAL AND EFFLUENT DOSE COMPARISON LIQUID RELEASE PATHWAY Environmental or Critical Critical MaximumDose(3 Organ Effluent Data Age (1)
Pathway (2)
Location (mrem)
Skin Skin Environmental Effluent Teen Teen
-. X
-f. -..
I.
Shoreline Sediment Shoreline Sediment 129 (0.51 mi. ENE) 0.5 mi. NNE 4.37E-04 3.33E-04 Bone Bone Environmental Effluent Child Child Fish Fish 128 (0.45 mi. NE) 0.5 mi. NNE 6.88E-02 8.23E-03 Liver Liver T. Body T. Body Thyroid Thyroid Kidney Kidney Lung Lung GI-LLI GI-LLI Environmental Effluent Environmental Effluent Environmental Effluent Environmental Effluent Environmental Effluent Environmental Effluent Child Child Adult Child Child Child Child Child Child Child Child Child Fish Drinking Water Fish Drinking Water Drinking Water Drinking Water Drinking Water Drinking Water Drinking Water Drinking Water Drinking Water Drinking Water 128 (0.45 mi. NE) 0.5 mi. NNE 128 (0.45 mi. NE) 0.5 mi. NNE 101 (3.31 mi. E) 0.5 mi. NNE 101 (3.31 mi. E) 0.5 mi. NNE 101 (3.31 mi. E) 0.5 mi. NNE 101 (3.31 mi. E) 0.5 mi. NNE 1.03E-01 8.59E-02 7.35E-02 7.93E-02 3.68E-02 7.79E-02 5.83E-02 8.05E-02 4.45E-02 7.88E-02 11.
3.72E-02 7.89E-02 Li (1) Critical Age is the highest total dose (all pathways) to an age group.
L_ (2) Critial Pathway is the highest individual dose within the identified Critical Age group.
~_ (3) Maximum dose is a summation of the fish, drinking water and shoreline sediment pathways.
Section 4 - Page 3
Page 2 of 3 GASEOUS RELEASE PATHWAY IODINE, PARTICULATE, and TRITIUM Ogn Environmental or Critical Critical MxmmDs 3
Organ Effluent Data Age (1)
Pathway 2)
Location (mrem)
D Skin Environmental 0.OOE+00 Skin Effluent All Ground Plane 0.5 mi. E 6.56E-06 Bone Environmental 0.OOE+00 Bone Effluent Child Ground Plane 0.5 mi. E 5.67E-06 Liver Environmental 0.00E+00 Liver Effluent Child Vegetation 0.5 mi. E 7.43E-01 T. Body Environmental 0.OOE+00 T. Body Effluent Child Vegetation 0.5 mi. E 7.43E-01 Thyroid Environmental 0.00E+00 Thyroid Effluent Child Vegetation 0.5 mi. E 7.43E-01 Kidney Environmental 0.OOE+00 Kidney Effluent Child Vegetation 0.5 mi. E 7.43E-01 Lung Environmental 0.OOE+00 Lung Effluent Child Vegetation 0.5 mi. E 7.43E-01 GI-LLI Environmental 0.OOE+00 GI-LLI Effluent Child Vegetation 0.5 mi. E 7.43E-01 (1) Critical Age is the highest total dose (all pathways) to an age group.
(2) Critial Pathway is the highest individual dose within the identified Critical Age group.
(3) Maximum dose is a summation of the ground/plane, inhalation, milk and vegetation pathways.
Section 4 - Page 4
Page 3 of 3 NOBLE GAS k
Air Environmental or Critical Critical Maximum Dose Dose Effluent Data Age Pathway Location (mrad)
Beta Environmental Not Sampled Beta Effluent N/A Noble Gas 0.5 mi.NNE 3.56E-02 Gamma Environmental Not Sampled Gamma Effluent N/A Noble Gas 0.5 mi.NNE 7.08E-02 Section 4 - Page 5
C CC CC CC CC C CC CCC C CCC CC C CCCCC C CC C CC C C C C C C c cC TABLE 4.1-B Maximnumn Individual Dose for 2003 based on Enviroinmental Measurements (mnrem) for McGu ire Nuclear Station Age Sample Medium Bone Liver T. Body Thyroid Kidney Lung GI-LLI Skin Infant Airborne Drinking Water Milk TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 3.57E-02 O.OOE+00 3.57E-02 O.OOE+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 3.57E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Child Airborne Drinking Water Milk Broadleaf Vegetation Fish Shoreline Sediment TOTAL Teen Airborne Drinking Water Milk Broadleaf Vegetation Fish Shoreline Sediment TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.88E-02 0.00E+00 6.88E-02 7
0.00E+00 0.00E+00 0.00E3+00 0.00E3+00 5.47E-02 0.00E+00 5.47E-02 0.00E+00 3.63E-02 O.OOE+00 0.00E+00 6.64E-02 0.00E+00 1.03E-01 n, ; ! e !; -
I 0.00E+00 1.90E-02 0.00E+00 O.OOE+00 7.33E-02 O.OOE+00 9.23E-02 0.00E+00 O.OOE+00 3.63E-02 3.63E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.02E-02 4.93E-04 7.83E-05 0.00E+00 4.66E-02 3.68E-02 0.00E+00 0.00E+00 1.90E-02 1.90E-02 O.OOE+00 O.OOE+00 0.00E+00 0.00E+00 2.59E-02 5.97E-04 3.75E-04 0.00E+00 4.53E-02 1.96E-02 O.OOE+00 3.63E-02 0.00E3+00 0.00E+00 2.20E-02 0.00E+00 5.83E-02 0.00E3+00 1.90E-02 0.00E+00 O.OOE+00 2.53E-02 0.00E+00 4.43E-02 0.00E+00 3.63E-02 0.00E+00 0.00E+00 8.22E-03 0.00E+00 4.45E-02 0.00E+00 1.90E-02 O.OOE+00 O.OOE+00 1.02E-02 O.OOE+00 2.92E-02 O.OOE+00 3.63E-02 0.00E+00 0.00E+00 9.06E-04 0.00E+00 3.72E-02
- i. -,
- m. ).
0.00E+00 1.90E-02 0.00E+00 0.00E+00 1.63E-03 0.00E+00 2.06E-02 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.14E-05 9.14E-05 0.00E3+00 O.OOE+00 0.00E3+00 O.OOE+00 0.00E+00 4.37E-04 4.37E-04 Adult Airborne 0.00E+00 O.OOE+00 O.OOE+00 Drinking Water 0.00E+00 2;69E-02 2.69E-02 Milk O.OOE+00 0.00E+00 0.00E+00 Broadleaf Vegetation 0.00E+00 O.OOE+00 O.OOE+00 Fish 5.10E-02 7.06E-02 4.65E-02 Shoreline Sediment O.OOE+00 O.OOE+00 6.71E-05 TOTAL 5.10E-02 9.75E-02 7.35E-02 Note: Dose tables are provided for sample media displaying positive nuclide occurrence.
Section 4 -Page 6 0.00E+00 2.69E-02 0.00E+00 0.00E+00 7.76E-04 0.00E+00 2.77E-02 0.00E+00 2.69E-02 0.00E+00 0.00E+00 2.45E-02 0.00E+00 5.14E-02 O.OOE+00 2.69E-02 O.OOE+00 0.00E+00 8.65E-03 0.00E+00 3.56E-02 0.00E+00 2.69E-02 0.00E+00 0.00E+00 2.13E-03 O.OOE+00 2.90E-02 0.00E+00 0.00E+00 O.OOE+00 0.00E+00 0.00E+00 7.83E-05 7.83E-05
CCrCCCC C C CC C CCC CCICCC (cCCCCCCcCcCCccIC McGuire Nuclear Station Dose from Drinking Water Pathwayfor 2003 Data Maximum Exposed Infant Infant Dose from Drinking Water Pathway (mrem) = Usage (I) x Dose Factor (mrem/pCi ingested) x Concentration (pCI/I)
Usage (Intake In one year) =
330 1 Radionucide Mn-54 CO-58 Fe-S9 Co-60 Zn-65 Nb-95 Zr-95 1.131 CS.134 Cs-137 BaLa-140 H-.3 Done NO DATA NO DATA 3.08E-05 NO DATA 1.84K-OS 4.20WA8 2.06E407 3.59E-05 3.77E-04 5.22W.04 1.71W.04 NO DATA Ineestion Dose Factor Liver T. Body Thyroid Kidney Lung GI.LLI 1.99KOS 4.51EW06 NO DATA 4.41W-06 NO DATA 7.31W-O6 3.60E-W6 L98E-06 NO DATA NO DATA NO DATA
.97E-06 53SW-05 2.12F-05 NO DATA NO DATA 1.59K-O5 257E-05 1.08KWO5 2.55K5 NO DATA NO DATA NO DATA 257W5 6.31K-W5 2.91K-O5 NO DATA 3.06E-OS NO DATA 5.33W-05 1.73K-O8 1.00K-O8 NO DATA 1.24K-O8 NO DATA 1.46K-O5 5.02K-O8 3.56K-O8 NO DATA 5.41EK-8 NODATA 2.50EK-5 4.23E-OS 1.86K-OS 1.39W-02 4.94E-05 NO DATA 1.51-06 7.03E-04 7.10K-OS NO DATA 1.81E.04 7A2E-O5 1.91W-06 6.11E-04 4.33K-O5 NO DATA 1.64R-04 6.64K-05 1.91E-06 1.71E-07 8.8-06 NO DATA 4.06E-08 1.05E-07 4.20EK-5 3.08E-07 3.08W-07 3.08E-07 3.OSE-07 3.OSE007 3.08E-07 Highest Annual Net Mean Concentration Dose (mrem)
Indicator Water Location (pClI)
Bone Liver T. Body Thyroid Kidney Lung GI.LLI ALL 0.00 0.OOE+00 O.OOE+00 O.OOE+O0 Q.OOE+0 Q.OOE+OO O.OOE+OO O.OOE+00 ALL 0.00 Q.OOE+00 O.OOE+OO O.OOE+O0 0.OOE+O0 O.OOE+OO QOOE+OO
.OOE+OO ALL 0.00 O.OOE+OO OOE+00 0
.00 E+OO QOOE.OO 0.OOE+O0 0.OOE+O0 O.OOE+00 ALL 0.00 O.OOE+0O O.00E+OO O.OOE+00 0.00E+00 O.00E+00 O.OOE+00 O.OOE+00 ALL 0.00 O.00E+O0 O.00E+O0 0.00E400 O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO ALL 0.00 O.00E+OO O.OOE+
OO
.OOE+OO 0.00E+OO O.OOE+00 O.OOE+OO ALL 0.00 Q.OOE+O0 O.OOE+00 O.00E+OO O.OOE+OO 0.00E+00 QOOE+OO O.OO+OO ALL 0.00 0.OOE+00 O.OOE+O0 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+O0 ALL 0.00 O.OOE+O0 O.OOE+OO O.OOE+OO O.OOE+00 O.OOEK00 O.OOE+00 QO.E+OO ALL 0.00 Q.OOE+O0 O.OE+OO 0O.OOE+00 O.O+OO O.OOE+OO Q.OOE+00 O.OOE+O0 ALL 0.00 O.OOE+OO 0.00E+00 O.OOE+OO O.OOE+00 0.00E+OO
.0.0K+WO O.OOE+OO 101 351.00 O.OOE+OO 357EW02 357E-02 3.S7E-02 3.57E-02 3-57E-02 3.57E-02 m) e O.OOE+00 3.57W-02 3-57E-02 3.57E-02 3.57E-02 3-57E-02 3-57E-02 Dose Commitment (mre Section 4 - Pagc 7
CCC(C C C CCCCCCCcCcCCCc CCCcCCCcCcCCCCCCccCC McGuire Nuclear Station Dose from Drinking Water Pathway for 2003 Data Maximum Exposed Child Child Dose from Drinking Water Pathway (mrem) = Usage (1) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)
Usage (Intake In one year)=
510 1 Ineestion Dose Factor HIghest Annual Net Mean Concentration Indicator Water Locstion (pCIII)
Dose (mrem)
Radionuclide Mn-S4 Co-58 Fe-S9 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs4137 BaLa.140 Bone NO DATA NO DATA 1.65E-05 NO DATA 1-37E-05 225E"S 1.16E-07 1.72W-05 2.34W-04 32J7E-04 S31W-05 Liver 1.07E-0S 1.80K-0G 2.67K-OS 5.29E.06 3.65E-0S 8.76E" 2.55F-OS 1.73E-O5 3.84E-04 3.13F,04 7.2E-08 T. Body 2'85K06 551E-06 1.33E-05 1.56E-5 2.27E-05 6.26E-09 2.27E.08 9.83E-046 SIOE-05 4.62E05 4SSE06 Thyroid Kidney Lung GI-LLI NO DATA 3.O0E-06 NO DATA 8.98E-06 NO DATA NO DATA NO DATA 1.05W-OS NO DATA NO DATA 7.74E4-6 2.78E-OS NO DATA NO DATA NO DATA 2.93E-5 NO DATA 2.30E4-5 NO DATA 6.41W-C6 NO DATA 8.23W-09 NO DATA 1.62E-OS NO DATA 3.65W-OS NO DATA 2.66E-OS 5.72W-03 2.84W-O5 NO DATA t.54W-06 NO DATA 1.19E-04 4.27WS 2.07WA6 NO DATA 1.02EW04 3.67W-05 1.96E-06 NO DATA 237E-0S 4.34E-OS 4.21EWOS ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 351.00 Bone Liver T. Body Thyroid 0.00E.00 0.00E400 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OO3+O00 0.00E+00 0.00E+00 0.00K+00 0.00E400 000OE400 0.00E+00 0.OOE+00 0.00E+O0 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE3+00 0.0013+00 0.OOE+00 0.OOE+00 0.OOE+00 0.001E+00 O.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.0.OOE 0
E00 0.001E+O0 0
.OOE+00 O0E O
0.OOE.00 0.00E+00 0.OOE+00 0.00E400 0.00E+00 0.0013400 0.00E+00 0.OOE+00 0.00E400 3.63E-02 3.63E-02 3.63E.02 Kidney Lung GI-LL1 0.001E+00 0.OOK+00 0.00E+00 0.OOE+O0 0.OOE.OO 0.0 K+O00 0.OOE400 0 OOE+00 0 OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+O0 0.00E+O00 0.0013-00 0.OOE+00 0.001EtOO 0.OOE+00 0.OOK+00 0.00K O00 0.0O1E+00 0.OOE+00 0.OOE+00 O.OOE+00 O.00KF+00 0.OOEO00 0.OOE+00 0.OOE+00 0.00E+00 3.63E-02 3.63K-O2 3.63E.02 H-3 NO DATA 2.03F-07 2.03F-07 2.03E-07 2.03E-07 2.03E-07 2.03E.07 Dose Commitment (mnrem) =
Section4-Page8 0.00E400 3.63E.02 3.63E.02 3.63E.02 3.63E-02 3.63K-02 3.63E.02
cccrccrC c crCcccccrC ccCccCcrCCCCrrCrCCCCCC c
McGuire Nuclear Station Dose from Fish Pathway for 2003 Data Maximum Exposed Child Child Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)
H-3 Concentration in Fish = Surface Water pCi/l x Bioaccumulation Factor 0.9 pCI/kg per pCi/l = 391 pCi/I x 0.9 = 352 pCi/kg Usage (intake in one year) =
6.9 kg Radionuclide Mn-54 Co-58 Fe-59 CO-60 Zn-65 Cs-134 Cs-137 H-3 Bone NO DATA NO DATA 1.65E-05 NO DATA 1.37E-os 2.34E-04 3.27E-04 NO DATA Liver T. Body 1.07E-05 2.85E-06 1.80E-06 s.51E-06 2 67-O05 133E-05 5.29R-O6 1.56-S05 3.65R-5 2.27R-05 3.84E-04 810R-S 3.13E-04 4.62E-05 2.03E-07 2.03E-07 Ineestion Dose Factor Thyroid Kidney Lung GC-LLI NO DATA 3.OOE-OC NO DATA 898E-06 NO DATA NO DATA NO DATA 1.05E-05 NO DATA NO DATA 7.74E-06 2.78RS NO DATA NO DATA NO DATA 2.93E-05 NO DATA 2.30E-05 NO DATA C.41E-O6 NO DATA 1.19E-04 4.27E-05 2.07E-0C NO DATA 1.02E4-4 3.67E-05 1.96E-06 2.03E-07 2.03R-07 2.03E-07 2.03E-07 Highest Annual Net Mean Concentration Dose (mrem)
Indicator Fish Loation (pCi/W)
Bone Liver T. Body Thyroid KIdney Lung GI-LLI ALL 0.00 O.OOE+OO O.OOE+0KOO 0.00E+OO 0.OOE+
O.OOE+O0 O.OOE+OO O.OOE+OO ALL 0.00 O.OOE+O0 O.OOE+0O O.OOE+00 O.OOE+OO 0.00E+OO 0.00E+O O.OOE+0OO ALL 0.00 O.OOE+0OO O.OOE+0O O.OOE+00 O.OOE+
0 O.OOE+0OO 0.00E+OO O.OOE+0OO ALL 0.00 O.OOE+0OO O.OOE+OO 0.00E+KOO 0.00EOO 0.00EOO 0.00E+OO O.OOE+O0 ALL 0.00 O.OOE+00 0.00E+OO 0.00E+OO O.OO0E+00 O.OOE+OO QO OO 0O.OOE+O0 ALL 0.00 O.OOE+0O O.OOE+0OO 0.00E+O O.OOtEOO 0.OOE+00 0.OOE+00 0.00E+OO 129 30.50 6.SSE-02 6.59E-02 9.72E-03 O.OOE+0OO 2.15E-02 7.72E-03 4.12E-04 128 352.00 0.00E+OO 4.93E-04 4.93E-04 4.93R-04 4.93E-04 493E-04 4.93E-04 Dose Commitment (mrem) =
C.88E-02 6.64E-02 1.02E-02 4.93E-04 2.20E-02 8.22E-03 9.06E-04 Section 4 - Page 9
McGuire Nuclear Station Dose from Shoreline Sediment Pathway for 2003 Data Maximum Exposed Child Shoreline Recreation =
14 hr (in one year)
Shore Width Factor =
0.3 (lake shore - location 129)
Shore Width Factor =
0.2 (river shoreline, location 130)
Sediment Surface Mass =
40 kg/r 2 Child Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCIm2) x Shore Width Factor x Sediment Surface Mass (kg/fn) x Sediment Concentration (pClIkg)
External Dose Factor Standing on Contaminated Ground Highest Annual Net Dose Mean Concentration (mrem/hr per pCln 2)
Radionuclide T. Body Skin Mn-54 5.80E-09 6.80E-09 Co-58 7.00E-09 8.20E.09 Co-60 1.70E-08 2.00E-08 Cs-134 1.20E-08 1AOE-08 Cs-137 4.20E-09 4.90E.09 Indicator Sediment Location (pCVkg)
ALL 0.00 ALL 0.00 ALL 0.00 ALL 0.00 129 111.00 (mrem)
T. Body Skin O.OOE+00 O.OOE+00 O.OOE+OO O.O0E+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO 7.83E-05 9.14E-05 7.83E-05 9.14E.05 Dose Commitment (mrem) =
Section 4 -Page 10
cICrCC C CCCCrCCCCCCCCC CCCCCCcCCrCCCC CCCCC McGuire Nuclear Station Dose from Drinking Water Pathway for 2003 Data Maximum Exposed Teen Teen Dose from Drinking Water Pathway (mrem) = Usage (I) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)
Usage (Intake In one year)=
510 1 Ingestion Dose Factor Highest Annual Net Mean Concentration Indicator Water Location (pCI/a)
Dose (mrem)
Radionuclide Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 I.131 Cs-134 Cs..137 BaLs.140 Bone NO DATA NO DATA 5.87E-06 NO DATA 5.76E-06 822E-09 4.12E-08 5.SE.06
&37E-05 1.12E-04 2.84E.-05 Uiver S.90E-06 9.72E-07 1.37E-05 2.81E-06 2.OOE-05 4.56E-09 1.30E-08
&19E-06 1.97E.04 1.49E-04 3.48E.08 T. Body 1.17E-06 2.24F,06 5.29E-06 6.331E-06 9.33E-06 2.51E-09 8.94E-09 4.401E.06 9.14E-05 5.19E-05 1.83E.06 Thyrold Kidney Lung GI-LLI NO DATA 1.76E-06 NO DATA 121E-OS NO DATA NO DATA NO DATA 1.34E.05 NO DATA NO DATA 432E-06 3,24E-0S NO DATA NO DATA NO DATA 3.66E-05 NO DATA 1.28E-05 NO DATA &.47E-06 NO DATA 4.42E-09 NO DATA 1.95E-05 NO DATA 1.91E-08 NO DATA 3.OOE-05 2.39E-03 IAIE-05 NO DATA 1.62E-06 NO DATA 6.26E-05 2.39E-05 2.45E-06 NO DATA 5.07E-05 1.97E-05 2.12E-06 NO DATA 1.18E-08 2.34E-08 4-38E05 ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 351.00 Bone 0.OOEO00 0.00E+O0 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 Liver O.OOE+00 0.OOE+00 O.OOE+O0 0.OOE+00 0.00E+00 0.001E+00 0.OOE+O0 0.OOE+O0 0.OOE+00 0.00E+00 1.90F,02 T. Body 0.OOE+O0 0.OOE+00 0.00E400 0.00E+00 0.001E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE3+00 0.OOE+00 1.90E-02 Thyroid 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+-00 0.00E+-00 0.OOE+O0 0.00E.00 0.OOE+00 0.O0E-i00 0.OOE+00 1.90E-02 Kidney Lung GI-LLI 0.00E.O0 0.00E+400 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.00E400 0.00E+00 0.OOE+00 1.90E.02 0.O0E+00 0.OOE+o0 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.90E-02 0.00E+00 0.O0E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.O0E+O0 0.001E+00 0.0E+00 0.OOE+00 1.90E-02 H.3 NO DATA 1.06E-07 1.06E.07 1.06E.07 1.06E-07 1.06E-07 1.06E-07 Dose Commitment (mrem)=
Section 4 - Page 11 0.00E+00 1.90E.02 1.90E.02 1.9013-02 1.90E.02 1.90E-02 1.90E.02
CCCCCCCCCCCCCCCICCCCCCC(C CCCCCCCCCCCCCCCCIcC McGuire Nuclear Station Dose from Fish Pathway for 2003 Data Maximum Exposed Teen Teen Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi Ingested) x Concentration (pCi/kg) 11-3 Concentration In Fish = Surface Water pCI/l x Bloaccumulation Factor 0.9 pCI/kg per pCi/i = 391 pCi/I x 0.9 = 352 pCi/kg Usage (Intake In one year) =
16 kg Radionudide Mn-54 Co-58 Fe-59 Co-SO Zn.65 Cs-134 Cs-137 11-3 Bone NO DATA NO DATA 5.87E-06 NO DATA S.76E-06 8.37E-05 1.12R.04 NO DATA Liver T. Body 5.90E-06 1.17E-06 9.72E-07 2.24E-06 1.37E-05 5.29E-06 2.81E-06 6.33E-06 2.00E-05 933E-06 1.97E-04 9.14R-05 1.49E-04 5.19E-OS 1.06E.07 1.06E-07 Infestlon Dose Factor Thyroid Kidney Lung GI-LLI NO DATA 1.76E-06 NO DATA 1.21K-O5 NO DATA NO DATA NO DATA 1.34E-OS NO DATA NO DATA 4.32E-06 3.24K-OS NO DATA NO DATA NO DATA 3.66K-05 NO DATA 1.2SK-5 NO DATA &47E-06 NO DATA 626E-OS 2.39KO05 2.45E-06 NO DATA 5.07E-OS 1.97E-OS 2.12E-06 1.06E-07 1.06R-07 1.06E-07 1.06E.07 Highest Annual Net Mean Dose (mrem)
Concentration Location (pCitkg)
Bone Liver T. Body Thyroid Kidney Lung GI-LLI ALL 0.00 QOOE+O E
O.OOE+OO O.OOE+O0 0.OOK+O0 0.OOE+OO Q.OOE+00 O.00E+00 ALL 0.00 0.00E+00 O.OOE+00 0.00E+00 O.OOE+00 0.OOE+OO 0.OOE+OO 0.00E+00 ALL 0.00 O.OOE+OO 0.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+iO0 ALL 0.00 0.OOE+0O O.OOE+OO 0.OOE+OO
.OOE+OO0 O.OOE+OO Q
OO Q0OOE.+OO ALL 0.00 O.OOE+O0 O.00E+O0 O.OOE+O0 O.OOE+O0 0.00E+O0 O.OOE+00 O.OOE+O0 ALL 0.00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+O0 Q.OOE+O0 129 30.50 5.47E402 7.27E-02 2.53E-02 0.00E+00 2.47E-02 9.61E-03 1.03E-03 128 352.00 O.OOE+O0 5.97E-04 5.97E-04 5.97E-04 5.97E-04 5.97E-04 5.97E-04 Dose Commitment (mrem) =
5.47E402 733E-02 2.59E02 5.97E-04 2.53E-02 1.02E-02 1.63E-03 Section 4 - Page 12
ccccCCCCCICCCCCCCCCC CCCCCC CCCCCCCICrCCCCCCC McGuire Nuclear Station Dose from Shoreline Sediment Pathway for 2003 Data Maximum Exposed Teen Shoreline Recreation =
67 hr (In one year)
Shore Width Factor =
0.3 (lake shore - location 129)
Shore Width Factor =
0.2 (river shoreline - location 130)
Sediment Surface Mass =
40 kg/m 2 Teen Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCI/m 2) x Shore Width Factor x Sediment Surface Mass (kg/n 2) x Sediment Concentration (pCIkg)
External Dose Factor Standing on Contaminated Ground Highest Annual Net Mean Concentration Dose (mrem/hr per pCi/ln)
Radionudide T. Body Skin Mn-54 5.80E-09 6.80E-09 Co-58 7.OOE-09 8.20E-09 Co-60 1.70E-08 2.OOE-08 Cs.134 1.20E-08 IAOE-08 Cs-137 4.20E-09 4.90E-09 Indicator Location ALL ALL ALL ALL 129 Sediment (pCI/kg) 0.00 0.00 0.00 0.00 111.00 (mrem)
T. Body Skin O.OOE+00 0.OOE+00 O.OOE+O0 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3.75E-04 4.37E-04 Dose Commitment (mrem) =
3.75E-04 4.37E-04 Section 4 - Page 13
C ( C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C CC C CC McGuire Nuclear Station Dose from Drinking Water Pathwayfor 2003 Data Maximum Exposed Adult Adult Dose from Drinking Water Pathway (mrem) = Usage (I) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/Q)
Usage (Intake In one year) =
730 1 Radlonuclide Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 BaLa-140 11-3 Bone NO DATA NO DATA 4.34E406 NO DATA 4.84W,06 6.22W-O9 3.04WR08 4.16W6O 6.22EW05 7.97FOS 2.03E-05 NO DATA Ineestion Dose Factor Liver T. Body Thyrold Kidney Lung GI-LLI 4.57E.06 8.72E-07 NO DATA 136E-06 NO DATA 1.40W-O5 7.45E-07 1.67E-06 NO DATA NO DATA NO DATA 1.51E-05 L02R-05 3.91E-06 NO DATA NO DATA 2.85E-06 3.40W-O5 2.14W,06 4.72E-06 NO DATA NO DATA NO DATA 4.02E-05 1.54E-05 6.96E-06 NO DATA 1.03E-OS NO DATA 9.70E-06 3.46E-W9 1.86E-O9 NO DATA 3.42W,09 NO DATA 2.10E-OS 9.75E-W9 6.60E-09 NO DATA 1.53K-08 NO DATA 3.09E-OS 5.95E-06 3.41E-06 1.95E-03 1.02KWO5 NO DATA 1.57E-06 1.48E-04 1.21W-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 1.09E-04 7.14E-05 NO DATA 3.70E-OS 1.23E-05 2.11W-06 2.55K-08 1.33E-06 NO DATA &67W-09 1.46E-08 4.18E-OS 1.05W-07 1.05W.07 1.05E-07 1.05E-07 1.05E-07 l.OSE-07 Highest Annual Net Mean Concentration Dose (mrem)
Indicator Water Location (pCI/I)
Bone Liver T. Body Thyrold Kidney Lung Gl-LLI ALL 0.00 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE.O0 O.OOE+OO O.OOE+00 O.OOE+00 ALL 0.00 Q.OOE+OO O.OOE+0O O.OOE+O0 O.OOE+O0
.OOE+OO O.OOE+OO Q.OOE+OO ALL 0.00 0.00MO O.OOE+00 O.OOE+O0 O.00E+0O O.OOE+O0 O.OOE+00 O.OOE+OO ALL 0.00 O.OOE+00 O.OOE+0O O.OOE+OO O.OOE+O0 Q.OOE+O0 O.OOE+O0 O.OOE+00 ALL 0.00 O.OOE+O0 O.OOE+00 O.OOE+0O O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+OO ALL 0.00 Q.OOE+O0 0.00Q O0E O.OOE+0O O.OOE+O0 O.OOE+O0 O.OOE+00 O.OOE+00 ALL 0.00 O.OOE+00 O.OOE+00 O.OOE+OO Q.OOE+O0 Q.OOE+00 O.OOE+OO O.OOE+00 ALL 0.00 O.OOE+0 O.OO+0 OE+.OOE OO0 E.OOE+00
.OOE+0O Q.OOE+0O O.OOE+00 ALL 0.00 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+OO Q.OOE+OO ALL 0.00 0.00E+O
.OOE+00 Q.OOE400 Q.OOE+00 0.00E+00 O.OOE+OO 0.00E+00 ALL 0.00 O.OOE+OO O.OOE+00 O.OOE+O0 O.OOE+O0 O.OOE+O0 Q.OOE+00 O.OOE+O 101 351.00 0.00Q+00 2.69E-02 2.69WA2 2.69E-02 2.69E-02 2.69E-02 2.69E-02 1m) =
Q.OOE+O0 2.69E-02 2.69E-02 2.69E-02 2.69E-02 2.69E-02 2.69E-02 Dose Commitment (mrel Section 4 -Page 14
ccccccccccccccCrccccCccCCCCCCCCccCCCCCrCCCcc McGuire Nuclear Station Dosefrom Fish Pathwayfor 2003 Data Maximum Exposed Adult Adult Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCI Ingested) x Concentration (pCI/kg)
H-3 Concentration In Fish = Surface Water pCi/I x Bloaccumulation Factor 0.9 pCi/kg per pCi/I = 391 pCi/I x 0.9 = 352 pCi/kg Usage (Intake in one year) =
21 kg Radonudlide Mn-54 Co-58 Fe-59 Co-40 Zn-45 Cs-34 Cs-137 11-3 Bone NO DATA NO DATA 4.34W-06 NO DATA 4.84U-W6 6.22W-OS 7.97E-05 NO DATA Liver 4.57K-06 7A5W-07 1.02KWO5 2.14W-06 1.54EK0S 1.4SE-04 1.09W-04 1.05E-07 Ingestion Dose Factor T. Body Thyroid KOdney Lung GI-LLI 872W-07 NO DATA 1-36E-6 NO DATA 1.40K-5 1.67W-O6 NO DATA NO DATA NO DATA 1.51K-O5 3.91K-06 NO DATA NO DATA 2S5W-6 3.40W-O5 4.72K-C6 NO DATA NO DATA NO DATA 4.02E-OS 6.96K-C6 NO DATA 1.03SE-NO DATA 9.70K-C6 121I-04 NO DATA 4.79K-S 1.59K-O5 2.59W-06 7.14K-OS NO DATA 3.70K-OS 123K-O5 2.11K-06 1.05LE-1.05W-07 1.05E-07 LOSE-07 1.05E-07 Highest Annual Net Mean Concentration Dose (mrern)
Location (pCIkg)
Bone Liver T. Body Thyrold Kidney Lung GI-LLI ALL 0.00 0.OOE+O0 O.OOE+OC C.OOE+00 O.OOE+O0 0.OOE+OO O.OOE+0 OO.OE+OO ALL 0.00 O.OOE+OO OOE+00 0
.00 E+OO 0.OOE+O0 0.OOE+O0 O.OOE+O0 O.OOE+00 ALL 0.00 0.OOE+
0 0.OOE+O0 O.OOE+OO O.OOE+O0 0.00E+0O 0.OOE+O0 O.OOE+O0 ALL 0.00 O.OOE++0 0.00EO0 O.OOE+O0 0.00E+00
.OOE+OO O.OOE+0 0.OOE+O0 ALL 0.00 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+0 O.OOE+O0 ALL 0.00 0.OOE+OO 0.OOE+0 QOOE+O0 O.OOE+O0 0.OOE+O0 0.OOE+OO O.OOE+OO 129 30.50 5.10C-02 6.98W02 4-57E-02 O.OOE+00 2.37E-02 7.88K-O3 1.35W-03 128 352.00
.00E+OO 7.76d-C4 7.76W-04 7.76-04 7.76E-04 7.76W-04 7.76E-04 m) u 5.10K-02 7.06E-02 4.6SE-02 7.76E-04 2.45E-02 8.65W-O3 2.13WO3 Dose Commitment (mre Section 4 - Page 15
CCCCCCCCCCCCC~~c~CCCCUCCCCCCCCCCCCCC(C(CCCCC McGuire Nuclear Station Dose from Shoreline Sediment Pathway for 2003 Data Maximum Exposed Adult Shoreline Recreation _
12 hr (in one year)
Shore Width Factor =
0.3 (lake shore. location 129)
Shore Width Factor =
0.2 (river shoreline - location 130)
Sediment Surface Mass =
40 kgrn2 Adult Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCi/rm2) x Shore Width Factor x Sediment Surface Mass (kg/fn) x Sediment Concentration (pCI/kg)
External Dose Factor Standing Highest Annual Net Dose on Contaminated Ground Mean Concentration (mrem)
(mrem/hr per pCVmu)
Indicator Sediment Radionuclide T. Body Skin Location (pCi/kg)
T. Body Skin Mn-54 5.80E-09 6.80E-09 ALL 0.00 O.OOE+00 O.OOE+00 Co-58 7.OOE-09 8.20E-09 ALL 0.00 O.OOE+00 0.OOE+00 Co-60 1.70E-08 2.OOE-08 ALL 0.00 O.OOE+00 O.OOE+00 Cs.134 1.20E-08 1AOE-08 ALL 0.00 O.OOE+00 0.OOE+00 Cs-137 4.20E-09 4.90E-09 129 111.00 6.71E-05 7.83E-05 Dose Commitment (mrem) =
6.71E-05 7.83E-05 Section 4 -Page 16
5.0 QUALITY ASSURANCE 5.1 SAMPLE COLLECTION EnRad Laboratories, Fisheries, and Aquatic Ecology performed the environmental sample collections as specified by approved sample collection procedures.
5.2 SAMPLE ANALYSIS EnRad Laboratories performed the environmental sample analyses as specified by approved analysis procedures.
EnRad Laboratories is located in Huntersville, North Carolina, at Duke Power Company's Environmental Center.
5.3 DOSIMETRY ANALYSIS Duke Power Company's Environmental Center The Radiation Dosimetry and Records group performed environmental dosimetry measurements as specified by approved dosimetry analysis procedures.
5.4 LABORATORY EQUIPMENT QUALITY ASSURANCE 5.41 DAILY QUALITY CONTROL EnRad Laboratories has an internal quality assurance program which monitors each type of instrumentation for reliability and accuracy. Daily quality control checks ensure that instruments are in proper working order and these checks are used to monitor instrument performance.
5.4.2 CALIBRATION VERIFICATION National Institute of Standards and Technology (NIST) standards that represent counting geometries are analyzed as unknowns at various frequencies ranging from weekly to annually to verify that efficiency calibrations are valid. The frequency is dependent upon instrument use and performance. Investigations are performed and documented should calibration verification data fall out of limits.
Section 5 - Page I
5.4.3 BATCH PROCESSING Method quality control samples are analyzed with sample analyses that are processed in batches.
These include gross beta in drinking water and all tritium analyses.
5.5 DUKE POWER INTERCOMPARISON PROGRAM EnRad Laboratories participated in the Duke Power Nuclear Generation Department Intercomparison Program during 2003.
Interlaboratory cross-check standards, including, Marinelli beakers, air filters, air cartridges, gross beta on smears, and tritium in water samples were analyzed at various times of the year by the four counting laboratories in Duke Power Company for this program. A summary of these Intercomparison Reports for 2003 is documented in Table 5.0-A.
5.6 DUKE POWER AUDITS The McGuire Radiation Protection Section was not audited by the Quality Assurance Group in 2003. A Quality Assurance audit was performed in January of 2002. There were no findings as a result of this 2002 audit.
EnRad Laboratories was not audited by the Quality Assurance Group in 2003. A Quality Assurance audit was performed in June of 2002. Laboratory practices and procedures were reviewed. No significant problems were identified as a result of this 2002 audit.
5.7 U.S. NUCLEAR REGULATORY COMMISSION INSPECTIONS The McGuire Nuclear Station Radiological Environmental Monitoring Program was audited by the NRC in January of 2003 (Reference 6.12). There were no findings or issues identified by the audit.
EnRad Laboratories was audited by the NRC in January of 2003. There were no findings of significance as a result of the audit.
There were some inspector recommendations as a result of the 2003 audit which are described in PIPs G 00014 and G-03-00016.
5.8 STATE OF NORTH CAROLINA INTERCOMPARISON PROGRAM EnRad Laboratories routinely participates with the State of North Carolina Department of Environmental Health and Natural Resources (DEHNR) in an intercomparison program. EnRad Laboratories sends air, water, milk, vegetation, sediment, and fish samples which have been collected to the State of North Carolina Radiation Protection Section for intercomparison analysis.
Section S - Page 2
5.9 TLD INTERCOMPARISON PROGRAM 5.9.1 NUCLEAR TECHNOLOGY SERVICES INTERCOMPARISON PROGRAM Radiation Dosimetry and Records participates in a quarterly TLD intercomparison program administered by Nuclear Technology Services, Inc.
of Roswell, GA.
Nuclear Technology Services irradiates environmental dosimeters quarterly and sends them to the Radiation Dosimetry and Records group for analysis of the unknown estimated delivered exposure. A summary of the Nuclear Technology Services Intercomparison Report is documented in Table 5.0-B.
5.9.2 STATE OF NORTH CAROLINA INTERCOMPARISON PROGRAM Radiation Dosimetry and Records routinely participates in a TLD intercomparison program. The State of Nofth Carolina Radiation Protection Section irradiates environmental dosimeters and sends them to the Radiation Dosimetry and Records group for analysis of the unknown estimated delivered exposure. A summary of the State of North Carolina Environmental Dosimetry Intercomparison Report for 2003 is documented in Table 5.0-B.
5.9.3 INTERNAL CROSSCHECK (DUKE POWER)
Radiation Dosimetry and Records participates in a quarterly TLD intracomparison program administered internally by the Dosimetry Lab. The Dosimetry Lab Staff irradiates environmental dosimeters quarterly and submits them for analysis of the unknown estimated delivered exposure. A summary of the Internal Cross Check (Duke Power) Result is documented in Table 5.0-B.
Section 5 - Page 3
TABLE 5.0-A DUKE POWER COMPANY INTERLABORATORY COMPARISON PROGRAM 2003 CROSS-CHECK RESULTS FOR ENRAD LABORATORIES Cross-Check samples are normally analyzed a minimum of three times. A status of "3 Pass" indicates that all three analyses yielded results within the designated acceptance range. A status of "1 Pass" indicates that one analysis of the cross-check was performed.
Footnote explanations are included following this data table.
Gamma in Water 3.5 liters Reference Sample l.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status ni/l Cit/l pCi/I 5/21/2003 Q032GWS Cr-51 1.32-2.35 E5 1.76 E5 1.79 E5 3 Pass Mn-54 6.23 - 11.05 E4 8.31 E4 8.62 E4 3 Pass Co-58 3.68 - 6.53 E4 4.91 E4 4.95 E4 3 Pass Fe-59 4.46-7.91 E4 5.95 E4 6.15 E4 3 Pass Co-60 4.27 -7.56 E4 5.69 E4 5.87 E4 3 Pass Zn-65 6.17 - 10.94 E4 8.23 E4 8.62 E4 3 Pass Cs-134 3.38-5.99 E4 4.50 E4 4.18 E4 3 Pass Cs-137 7.37 - 13.07 E4 9.83 E4 9.51 E4 3 Pass Ce-141 1.45 -2.56 E5 1.93 E5 1.95 E5 3 Pass Co-57 0.00- 0.00 EO 0.00 EO 5.90 E2 3 Pass"'
Ce-139 0.00-0.00 E0 0.00 Eo 8.20 E2 3 Pass"'
12/23/2003 Q034GWR Cr-51 2.32-4.11 E3 3.09 E3 3.21 E3 3 Pass Mn-54 1.88-3.34 E3 2.51 E3 2.58 E3 3 Pass Co-58 1.10- 1.95 E3 1.47 E3 1.50 E3 3 Pass Fe-59 0.95 - 1.68 E3 1.26 E3 1.39 E3 3 Pass Co-60 1.72 - 3.05 E3 2.29 E3 2.28 E3 3 Pass Zn-65 2.13-3.78 E3 2.84 E3 2.95 ES 3 Pass Cs-134 1.50-2.66 E3 2.00 E3 1.92 E3 3 Pass Cs-137 1.44-2.56 E3 1.93 E3 1.84 E3 3 Pass Ce-141 1.74-3.09 E3 2.33 E3 2.36 E3 3 Pass Co-57 0.00-0.00 EO 0.00 EO 9.78 El 3 Pass~
1 )
Ce-139 0.00 -0.00 E0 0.00 E0 3.52 El 3 Pass_
Gamma in Water 1.0 Wer Reference Sample l.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status
- _Ci/I pCiA
, Ci/I 5/21/2003 Q032GWS Cr-51 1.32-2.35 E5 1.76 E5 1.79 E5 3 Pass Mn-54 6.23-11.05 E4 8.31 E4 8.61 E4 3 Pass Co-58 3.68-6.53 E4 4.91 E4 4.91 E4 3 Pass Fe-59 4.46-7.91 E4 5.95 E4 6.26 E4 3 Pass Co-60 4.27-7.56 E4 5.69 E4 5.91 E4 3 Pass Zn-65 6.17-10.94 E4 8.23 E4 8.85 E4 3 Pass Cs-134 3.38 -5.99 E4 4.50 E4 3.95 E4 3 Pass Cs-137 7.37 - 13.07 E4 9.83 E4 9.36 E4 3 Pass Ce-141 1.45-2.56 E5 1.93 E5 1.94 E5 3 Pass Co-57 0.00-0.00 E0 0.00 EO 5.19 E2 3 Pass(")
Ce-139 0.00-0.00 EQ 0.00 EO 8.83 E2 3 Pass"'
Section 5 - Page 4
Gamma in Water 1.0 liter, continued Reference Sample I.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status
-pCi/I pCi/l 12/23/2003 Q034GWR Cr-51 2.32-4.11 E3 3.09 E3 3.19 E3 3 Pass Mn-54 1.88 - 3.34 E3 2.51 E3 2.65 E3 3 Pass Co-58 1.10 - 1.95 E3 1.47 E3 1.55 E3 3 Pass Fe-59 0.95 - 1.68 E3 1.26 E3 1.42 E3 3 Pass Co-60 1.72 - 3.05 E3 2.29 E3 2.35 E3 3 Pass Zn-65 2.13-3.78 E3 2.84 E3 2.97 E3 3 Pass Cs-134 1.50-2.66 E3 2.00 E3 1.81 E3 3 Pass Cs-137 1.44 -2.56 E3 1.93 E3 1.87 E3 3 Pass Ce-141 1.74-3.09 E3 2.33 E3 2.38 E3 3 Pass Co-57 0.00- 0.00 EO 0.00 EO 8.90 El 3 Passt1" Ce-139 0.00-0.00 EO 0.00 EO 3.57 El 3 Pass_
Gamma in Water 0.5 liter Reference Sample l.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date
' Range Value Value Status
_ _ill pCi/I pCi/I 5/21/2003 Q032GWS Cr-51 1.32-2.35 E5 1.76 E5 1.75 E5 3 Pass Mn-54 6.23 - 11.05 E4 8.31 E4 8.72 E4 3 Pass Co-58 3.68-6.53 E4 4.91 E4 4.95 E4 3 Pass Fe-59 4.46 -7.91 E4 5.95 E4 6.35 E4 3 Pass Co-60 4.27 -7.56 E4 5.69 E4 5.87 E4 3 Pass Zn-65 6.17 - 10.94 E4 8.23 E4 8.96 E4 3 Pass Cs-134 3.38-5.99 E4 4.50 E4 3.93 E4 3 Pass Cs-137 7.37-13.07 E4 9.83 E4 9.51 E4 3 Pass Ce-141 1.45-2.56 ES 1.93 E5 1.94 ES 3 Pass Co-57 0.00-0.00 EO 0.00 EO 6.42 E2 3 Pass" Ce-139 0.00-0.00 EO 0.00 EO 8.19 E2 3 Pass' 12/23/2003 Q034GWR Cr-51 2.32-4.11 E3 3.09 E3 3.24 E3 3 Pass Mn-54 1.88-3.34 E3 2.51 E3 2.64 E3 3 Pass Co-58 1.10 - 1.95 E3 1.47 E3 1.52 E3 3 Pass Fe-59 0.95 - 1.68 E3 1.26 E3 1.41 E3 3 Pass Co-60 1.72 - 3.05 E3 2.29 E3 2.33 E3 3 Pass Zn-65 2.13 - 3.78 E3 2.84 E3 3.00 E3 3 Pass Cs-134 1.50-2.66 E3 2.00 E3 1.75 E3 3 Pass Cs-137 1.44-2.56 E3 1.93 E3 1.84 E3 3 Pass Ce-141 1.74-3.09 E3 2.33 E3 2.35 E3 3 Pass Co-57 0.00-0.00 EO 0.00 EO 8.72 El 3 Pass Gamma in Water 0.25 liter Reference Sample I.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pi-.
- pCi/N
- .a.
pCi/l 5/21/2003 Q032GWS Cr-51 1.32-2.35 E5 1.76 E5 1.79 E5 3 Pass Mn-54 6.23 - 11.05 E4 8.31 E4 8.80 E4 3 Pass Co58 3.68 -6.53 E4 4.91 E4 5.01 E4 3 Pass Fe-59 4.46-7.91 E4 5.95 E4 6.50 E4 3 Pass Co-60 4.27 - 7.56 E4 5.69 E4 5.99 E4 3 Pass Zn-65 6.17 - 10.94 E4 8.23 E4 9.08 E4 3 Pass Cs-134 3.38-5.99 E4 4.50 E4 4.01 E4 3 Pass Cs-137 7.37 - 13.07 E4 9.83 E4 9.58 E4 3 Pass Ce-141 1.45-2.56 E5 1.93 E5 1.97 ES 3 Pass Co-57 0.00-0.00 EO 0.00 EO 5.83 E2 3 Passfl)
Ce-139 0.00-0.00 E0 0.00 EO 7.90 E2 3 Pass Section 5 -Page 5
Gamma in Water 0.25 liter, continued Reference Sample I.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status piA pCiA1 pCi/l.
12/23/2003 Q034GWR Cr-51 2.32-4.11 E3 3.09 E3 3.33 E3 3 Pass Mn-54 1.88-3.34 E3 2.51 E3 2.59 E3 3 Pass Co-58 1.10-1.95 E3 1.47 E3 1.55 E3 3 Pass Fe-59 0.95-1.68 E3 1.26 E3 1.39 E3 3 Pass Co-60 1.72 - 3.05 E3 2.29 E3 2.33 E3 3 Pass Zn-65 2.13-3.78 E3 2.84 E3 3.15 E3 3 Pass Cs-134 1.50-2.66 E3 2.00 E3 1.76 E3 3 Pass Cs-137 1.44-2.56 E3 1.93 E3 1.86 E3 3 Pass Ce-141 1.74-3.09 E3 2.33 E3 2.35 E3 3 Pass Co-57 0.00-0.00 EO 0.00 EO 1.12 E3 3 Pass("
Ce-139 0.00 - 0.00 EO 0.00 EO 3.49 El 3Pass Gamma in Filter Reference Sample l.D.
Nuclide
-Acceptance Reference Mean Reported
- Cross Check Date
-Range
- =
- Value Value Status pCi/total pCi/total pCi/total 12/11/2003 E4020-37 Cr-51 1.39-2.53 E2 1.87 E2 1.88 E2 3 Pass Mn-54 0.86-1.53 E2 1.15 E2 1.19 E2 3 Pass Co-58 5.56-9.86 El 7.41 El 7.61 El 3 Pass Fe-59 5.12-9.08 El 6.83 El 6.63 El 3 Pass Co-60 0.78-1.38 E2 1.03 E2 1.07 E2 3 Pass Zn-65 1.20-2.14 E2 1.60 E2 1.25 E2 3 Pass"'
Cs-134 6.80- 12.06 El 9.07 El 9.09 El 3 Pass Cs-137 6.44 - I IA2 El 8.58 El 8.11 El 3 Pass Ce-141 1.01 -1.79 E2 1.35 E2 1.37 E2 3 Pass Co-57 0.00 -0.00 EO 0.00 EO 3.48 EO 3 Pass-)
Iodine in Water Reference Sample l.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date I
-Range Value Value Status 1 2
-piA E2 6pCi pCi2 5
1/10/2003 Q031LIWI 1-131 3.64-6.46 E2 4.86 E2 5.40 E2 3_Pass 1/10o2003 Q031LIW2 1-131 1.22-4.90 E0 2.45 E0 2.53 EO 3 Pass 1/1012003 Q031LIW3 1-131 4.91 - 8.71 El 6.55 El 5.64 El 3 Pass 7/11/2003 Q033LIW1 1-131 6.65-11.78 E2 8.86 E2 10.10 E2 3 Pass 7/1/2003 Q033LIW2 1-131 3.56 -6.87 EO 4.94 EO 6.82 E0 1/3 High" 71112003 Q033LIW3 1-131 1.68 -2.97 E2 2.23 E2 2.51 E2 3 Pass Iodine in Milk Reference Sample I.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value' Value Status pCi/l pCiA pCi/I 5/21/2003 Q032LIMI 1-131 4.63 -8.22 E2 6.18 E2 6.07 E2 3 Pass 5/21/2003 Q032LIM2 1-131 1.97-3.49 E2 2.63 E2 2.52 E2 3 Pass 5121/2003 l Q032LIM3 1-131 0.00-0.00 EO 0.00 EO 0.00 EO 3 Pass Section S -Page 6
Iodine in Milk, continued Reference Sample I.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date
-Range Value Value Status
.: -pCi/l pCiII pC/I 11/18/2003 Q034LIM1 1-131 4.10-7.27 E2 5.47 E2 6.10 E2 3 Pass 11118/2003 Q034LIM2 1-131 0.00r0.00 EO 0.00 EO 0.00 EO 3 Pass 11/18/2003 Q034LIM3 1-131 1.92-3.40 El 2.56 El 2.65 El 3 Pass Iodine Cartridge Reference Sample I.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date
-Range
-Value Value Status
- ,pCii -
pCi pOi 611212003 E3678-37 1-131 4.65 - 8.25 El 6.20 El 8.14 El 3 Pass Cs-137 O.00-O.OO E0 0.00 E0 58.77 E0 3 Pass(4) 12/111/2003 E4021-37 [
1-131 l5.97 - 10.58 El 7.96 El 9.33 El 3 Pass Cs, 0.0-.0.0 0.0E 8.772 Beta in Water Reference Sample l.D.
Nuclide Acceptance Reference Mean Reported
- Cross Check Date Range Value Value '
Status
- _C_
WY pCi/I 9/1812003 E3849-37 Gross Beta 1.85-3.27 E2 2.46 E2 2.26 E2 3 Pass Beta Smear Reference Sample l.D.
Nuclide Acceptance :
Reference Mean Reported Cross Check Date Rang e=
Value Value Status
_ _dpm dpm dpm l
5/16/2003 A16754-37 Gross Beta 7.09 - 12.58 E3 9.46 E3 9.20 E3
_3 Pass Tritium in Water Reference l Sample I.D.
Nuclide Acceptance Reference Mean Reported Cross Check Date I
Range Value Value Status
-A=PCi/: :--:
cn I
Pan I..
512112003 QO32TWSI H-3 0.00-0.00 E0 0.00 E0 0.00 E0 3 Pass 512112003 Q032TWS2 H-3 5.83 - 10.35 E4 7.78 E4 6.89 E4 3 Pass 1212312003 Q034TWRI H-3 1.37-4.07 E2 2.37 E2 3.19 E2 3 Pass 12/23/2003 1 Q034TWR21 H-3 0.00-0.00 E0 0.00 EO 0.00 EO 1
3 Pass 12/23/2003 1 Q034TWR3 H-3 0.97-1.73 E3 1.30 E3 1.31 E3 3 Pass Section 5 - Page 7
Table 5.0-A Footnote Explanations (1) Gamma in Water, Sample ID Q032GWS, Reference Date 5/21/2003: 3.5 L Marinelli, 1.0 L Marinelli, 0.5 L Marinelli, 0.25 L Marinelli Gamma in Water, Sample ID Q034GWR, Reference Date 12/23/2003: 3.5 L Marinelli, 1.0 L Marinelli, 0.5 L Marinelli, 0.25 L Marinelli Co-57 and Ce-139 were observed in cross-checks and was attributed to a contaminant arriving with the source.
The nuclides were determined to be present, but there was no reference activity applicable to the results. Ce-139 was not detected in the Q034GWR, Reference Date 12/23/2003 0.5 L Marinelli analysis.
(2) Gamma in Filter, Sample ID E4020-37, Reference Date 12/11/2003 Cross-check was vendor-prepared.
Zn-65 activities for this cross-check were consistently low. The source was analyzed at Catawba and similar results were observed. Co-57 was an unintended contaminant in the sample. General Office PIP G-04-00047 was written to record investigative actions.
Gamma in Filter, Sample ID E3677A-37, Reference Date 6/12/2003 was a vendor-prepared cross-check.
A uniform overestimation of about 72% for all nuclides was consistently observed in each analysis. The source or its calibration certificate was determined to be in error. Data for this cross-check was not included in the Annual Radiological Environmental Operating Report. General Office PIP G-04-00039 was written to record investigative actions.
(3) Iodine in Water, Sample ID Q033LIW2, Reference Date 7/1/2003 Three results for low-level 1-131 [364.48 keV] analysis were reported, with one being above acceptance limit. General Office PIP G-04-00146 was written to record investigative actions.
(4) Iodine Cartridge, Sample ID E3678-37, Reference Date 6/12/2003 Cs-137 is a known contaminant of the charcoal media and was detected in all reported analyses. The nuclide was determined to be present, but there was no reference activity applicable to the results.
Section 5 - Page 8
TABLE 5.0-B 2003 ENVIRONMENTAL DOSIMETER CROSS-CHECK RESULTS Nuclear Technology Services Ist Quarter 2003 TLD Delivered Reported Bias Pass/Fail Number (mrem)
(mrem)
(% diff)
Criteria Pass/Fail 101327 89 95.2 6.97
<+1-15%
Pass 101200 89 97.0 8.99
<+1-15%
Pass 101166 89 95.7 7.53
<+1-15%
Pass 101102 89 96.6 8.54
<+1-15%
Pass 101274 89 94.7 6.40
<+1-15%
Pass Average Bias (B) 7.69 Standard Deviation (S) 1.07 Measure Performance IBI+S 8.76
<15%
Pass 2nd Quarter 2003 TLD Delivered Reported Bias Pass/Fail Number (mrem)
(mrem)
(% diff)
Criteria Pass/Fail 101196 70 71.9 2.71
<+1-15%
Pass 101149 70 74.8 6.86
<+/-15%
Pass 101152 70 71.8 2.57
<+1-15%
Pass 101188 70 76.4 9.14
<+1-15%
Pass 101151 70 72.7 3.86
<+1-15%
Pass Average Bias (B) 5.03 Standard Deviation (S) 2.87 Measure Performance IB1+S 7.90
<15%
Pass 3rd Quarter 2003 4th Quarter 2003 TLD Delivered Reported Bias Pass/Fail TLD Delivered Reported Bias Pass/Fail Number (mrem)
(mrem)
(% diff)
Criteria Pass/Fail Number (mrem)
(mrem)
(% diff)
Criteria Pass/Fail 100113 90 93.8 4.22
<+1-15%
Pass 100075 76.4 81.7 6.94
<+1-15%
Pass 100215 90 94.4 4.89
<+1-15%
Pass 100397 76.4 83.2 8.90
<+1-15%
Pass 100138 90 94.4 4.89
<+1-15%
Pass 100335 76.4 82.7 8.25
<+1-15%
Pass 100380 90 93.5 3.89
<+1-15%
Pass 100050 76.4 82.0 7.33
<+1-15%
Pass 100126 90 93.7 4.11
<+1-15%
Pass 100030 76.4 83.8 9.69
<+1-15%
Pass Average Bias (B) 4.40 Average Bias (B) 8.22 Standard Deviation (S) 0.46 Standard Deviation (S) 1.12 Measure Performance IBI+S 4.86
<15%
Pass Measure Performance IBI+S 9.34
<15%
Pass State of North Carolina, Division of Radiation Protection Spring 2003 Fall 2003 TLD Delivered Reported Bias Pass/Fail TLD Delivered Reported Bias Pass/Fail Number (mrem)
(mrem)
(% diff)
Criteria Pass/Fail Number (mrem)
(mrem)
(% diff)
Criteria Pass/Fail 100964 65 70.0 7.69
<+1-15%
Pass 100940 59.4 63.1 6.23
<+1-15%
Pass 100159 65 72.2 11.08
<+1-15%
Pass 100723 59.4 58.8
-1.01
<+1-15%
Pass 100815 65 69.1 6.31
<+1-15%
Pass 100747 59.4 61.2 3.03
<+1-15%
Pass 100759 65 70.5 8.46
<+1-15%
Pass 101020 59.4 59.0
-0.67
<+/-15%
Pass 100150 65 72.3 11.23
<+1-15%
Pass 100080 59.4 60.8 2.36
<+1-15%
Pass 100823 65 72.2 11.08
<+1-15%
Pass 100356 59.4 60.7 2.19
<+1-15%
Pass 100169 65 67.9 4.46
<+1-15%
Pass 100818 59.4 59.6 0.34
<+1-15%
Pass 100921 65 71.1 9.38
<+1-15%
Pass 101122 59.4 59.4 0.00
<+1-15%
Pass Average Bias (B) 8.71 Average Bias (B) 1.56 Standard Deviation (S) 2.48 Standard Deviation (S) 2.41 Measure Performance IBI+S 11.19
<15%
Pass Measure Performance B +S 3.96
<15%
Pass Section 5 - Page 9
Internal Crosscheck (Duke Power) 1st Quarter 2003 TLD Delivered Reported Number (mrem)
(mrem) 100050 39 37.5 100030 39 37.3 100008 39 36.3 100140 39 39.3 100007 39 36.7 100957 39 38.1 100996 39 37.5 100940 39 38.9 100954 39 37.0 100955 39 38.0 Average Bias (B)
Standard Deviation (S)
Measure Performance lB 1+S 3rd Quarter 2003 TLD Delivered Reported Number (mrem)
(mrem) 100511 26 25.8 100552 26 25.9 100590 26 26.0 100470 26 25.8 100481 26 25.8 101201 26 24.4 101204 26 25.6 101205 26 25.0 101207 26 25.4 101208 26 25.6 Average Bias (B)
Standard Deviation (S)
Measure Performance IBI+S Bias Pass/Fail
(% diff)
Criteria Pass/Fail
-3.85
<+1-15%
Pass
-4.36
<+1-15%
Pass
-6.92
<+1-15%
Pass 0.77
<+1-15%
Pass
-5.90
<+1-15%
Pass
-2.31
<+1-15%
Pass
-3.85
<+1-15%
Pass
-0.26
<+1-15%
Pass
-5.13
<+1-15%
Pass
-2.56
<+1-15%
Pass
-3.44 2.41 5.84
<15%
Pass 2nd Quarter 2003 TLD Delivered Reported Bias Pass/Fail Number (mrem)
(mrem)
(% diff)
Criteria Pass/Fail 100155 65 63.0
-3.08
<+1-15%
Pass 100792 65 64.7
-0.46
<+1-15%
Pass 100769 65 64.4
-0.92
<+1-15%
Pass 100061 65 64.7
-0.46
<+1-15%
Pass 100799 65 63.4
-2.46
<+1-15%
Pass 100117 65 63.7
-2.00
<+1-15%
Pass 100012 65 63.8
-1.85
<+1-15%
Pass 100114 65 65.0 0.00
<+1-15%
Pass 100366 65 64.8
-0.31
<+1-15%
Pass 100314 65 63.9
-1.69
<+1-15%
Pass Average Bias (B)
-1.32 Standard Deviation (S) 1.04 Measure Performance lB1+S 2.36
<15%
Pass 4
Bias Pass/Fail
(% diff)
Criteria Pass/Fail
-0.77
<+1-15%
Pass
-0.38
<+1-15%
Pass 0.00
<+1-15%
Pass
-0.77
<+1-15%
Pass
-0.77
<+/-15%
Pass
-6.15
<+1-15%
Pass
-1.54
<+1-15%
Pass
-3.85
<+1-15%
Pass
-2.31
<+1-15%
Pass
-1.54
<+1-15%
Pass
-1.81 1.88 3.69
<15%
Pass 4th Quarter 2003 TLD Delivered Reported Number (mrem)
(mrem) 100085 39 37.9 100976 39 38.5 101413 39 37.2 101397 39 37.0 100260 39 39.0 100584 39 38.2 100343 39 38.4 100158 39 37.2 100225 39 41.7 100112 39 37.7 Average Bias (B)
Standard Deviation (S)
Measure Performance lBl+S Bias Pass/Fail
(% diff)
Criteria Pass/Fail
-2.82
<+1-15%
Pass
-1.28
<+1-15%
Pass
-4.62
<+1-15%
Pass
-5.13
<+1-15%
Pass 0.00
<+/-15%
Pass
-2.05
<+1-15%
Pass
-1.54
<+1-15%
Pass
-4.62
<+1-15%
Pass 6.92
<+1-15%
Pass
-3.33
<+1-15%
Pass
-1.85 3.50 5.34
<15%
Pass Section 5 - Page 10
6.0 REFERENCES
6.1 McGuire Selected License Commitments 6.2 McGuire Technical Specifications 6.3 McGuire Updated Final Safety Analysis Report 6.4 Duke Power Company McGuire Offsite Dose Calculation Manual 6.5 McGuire Annual Radiological Environmental Operating Report 1979 - 2002 6.6 McGuire Annual Radioactive Effluent Release Report 2003 6.7 Probability and Statistics in Engineering and Management Science, Hines and Montgomery, 1969, pages 287-293.
6.8 Practical Statistics for the Physical Sciences, Havilcek and Crain, 1988, pages 83-93.
6.9 Nuclear Regulatory Commission Regulatory Guide 1.109, Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purposes of Evaluating Compliance with 10CFR50, Appendix I.
6.10 EnRad Laboratories Operating Procedures 6.11 RETDAS, Radiological Effluent Tracking and Dose Assessment Software, Canberra Version 3.5.1, DPC Revision #4.0 6.12 NRC Integrated Inspection Report (50-369/03-02, 50-370/03-02) 6.13 Duke Power Company EnRad Laboratory Charcoal Cartridge Study, performed 2001 Section 6 - Page I
APPENDIX A ENVIRONMENTAL SAMPLING ANALYSIS PRO CEDURES Appendix A - Page I
APPENDIX A ENVIRONMENTAL SAMPLING AND ANALYSIS PROCEDURES Adherence to established procedures for sampling and analysis of all environmental media at McGuire Nuclear Station was required to ensure compliance with Station Selected Licensee Commitments.
Analytical procedures were employed to ensure that Selected Licensee Commitments detection capabilities were achieved.
Environmental sampling and analyses were performed by EnRad Laboratories, Dosimetry and Records, and Fisheries and Aquatic Ecology.
This appendix describes the environmental sampling frequencies and analysis procedures by media type.
- 1. CHANGE OF SAMPLING PROCEDURES Location 133 (Air Radioiodine & Particulate) was determined to be located in the ENE sector at 6.23 miles following 2003 GPS (Global Positioning System) measurement.
Previous documentation listed the location as in the NE sector at 6.2 miles. No site relocation or modifications were necessary as a result of the change.
The indicator dairy at location 138 (3.10 mi ESE) discontinued operation. Changes to the milk sampling program were implemented effective 2/12/2003. A replacement dairy was not available.
Location 188 (Garden) was determined to be in the NNE sector at 2.79 miles following 2003 GPS measurement. Previous documentation listed the location as in the N sector at 2.8 miles. No site relocation or modifications were necessary as a result of the change.
Location 190 (Site Boundary TLD) was moved within the WSW sector due to accessibility and field safety concerns. The TLD was moved from 0.40 miles to new location within the WSW sector at 0.33 miles.
- 11.
DESCRIPTION OF ANALYSIS PROCEDURES Gamma spectroscopy analyses are performed using high purity germanium gamma detectors and Canberra analytical software. Designated sample volumes are transferred to appropriate counting geometries and analyzed by gamma spectroscopy. Perishable samples such as fish and broadleaf vegetation are ground to achieve a homogeneous mixture. Soils and sediments are dried, sifted to remove foreign objects (rocks, clams, glass, etc.) then transferred to Appendix A - Page 2
appropriate counting geometry. Ten percent of samples receiving gamma analysis are analyzed as duplicate analyses.
Low-level iodine analyses are performed by passing a designated sample aliquot through a pre-weighed amount of ion exchange resin to remove and concentrate any iodine in the aqueous sample (milk). The resin is then dried, mixed thoroughly, and a net resin weight determined before being transferred to appropriate counting geometry and analyzed by gamma spectroscopy.
Tritium analyses are performed quarterly by using low-level environmental liquid scintillation analysis technique on a Packard 2550 liquid scintillation system.
Tritium samples are batch processed with a tritium spike to verify instrument performance and sample preparation technique are acceptable.
Gross beta analysis is performed by concentrating a designated aliquot of sample precipitate and analyzing by gas-flow proportional counters. Samples are batch processed with a blank to ensure sample contamination has not occurred.
III.
CHANGE OF ANALYSIS PROCEDURES No analysis procedures were changed during 2003.
IV.
SAMPLING AND ANALYSIS PROCEDURES A.1 AIRBORNE PARTICULATE AND RADIGIODINE Airborne particulate and radioiodine samples at each of six locations were composited continuously by means of continuous air samplers. Air particulates were collected on a particulate filter and radioiodines were collected in a charcoal cartridge positioned behind the filter in the sampler. The samplers are designed to operate at a constant flow rate (in order to compensate for any filter loading) and are set to sample approximately 2 cubic feet per minute. Filters and cartridges were collected weekly.
A separate weekly gamma analysis was performed on each charcoal cartridge and air particulate. A weekly gross beta analysis was performed on each filter. The continuous composite samples were collected from the locations listed below.
Location 120
=
Site Boundary (0.46 mi. NNE)
Location 121
=
Site Boundary (0.47 mi. NE)
Location 125
=
Site Boundary (0.38 mi. SW)
Location 133
=
Cornelius (6.23 mi. ENE)
Location 134
=
East Lincoln Jr. High School (8.77 mi. WNW)
Location 192
=
Peninsula (2.84 mi. NNE)
Location 195
=
Fishing Access Road (0.19 mi. N)
Appendix A - Page 3
A.2 DRINKING WATER Biweekly composite samples were collected. A gross beta and gamma analysis was performed on monthly composites. Tritium analysis was performed on the quarterly composites.
The composites were collected biweekly from the locations listed below.
Location 101 Location 119 Location 132 Location 136 Location 194 North Mecklenburg Water Treatment Facility (3.31 mi E)
Mt. Holly Municipal Water Supply (7.40 mi. SSW)
Charlotte Municipal Water Supply (11.1 mi. SSE)
Mooresville Municipal Water Supply (12.7 mi. NNE)
East Lincoln County Water Supply (6.73 mi. NNW)
A.3 SURFACE WATER Biweekly composite samples were collected. A gamma analysis was performed on the monthly composites.
Tritium analysis was performed on the quarterly composites sample. The composites were collected biweekly from the locations listed below.
Location 128 Location 131 Location 135 Discharge Canal Bridge (0.45 mi. NE)
Cowans Ford Dam (0.64 mi. WNW)
Plant Marshall Intake Canal (11.9 mi. N)
A.4 MILK Biweekly grab samples were collected at each dairy. A gamma and low-level Iodine-131 analysis was performed on each sample. The biweekly grab samples were collected from the locations listed below.
Location 138 Location 139 Location 141 Henry Cook Dairy - Cows (3.10 mi. ESE)
William Cook Dairy (2.49 mi. E)
Lynch Dairy - Cows (14.8 mi. WNW)
A.5 BROADLEAF VEGETATION Monthly samples were collected as available and a gamma analysis was performed on each sample. The samples were collected from the locations listed below.
Location 120 Location 125 Location 134 Location 193 Site Boundary (0.46 mi. NNE)
Site Boundary (0.38 mi. SW)
East Lincoln Junior High School (8.77 mi. WNW)
Site Boundary (0.19 mi. N)
Appendix A - Page 4
A.6 FOOD PRODUCTS Samples were collected monthly when available during the harvest season and a gamma analysis was performed on each. The samples were collected at the location listed below.
Location 188
=
5 mile radius Gardens (2.79 mi NNE)
A.7 FISH Semiannual samples were collected and a gamma analysis was performed on the edible portions of each sample. Boney fish (i.e. Sunfish) were prepared whole minus the head and tail portions. The samples were collected from the locations listed below.
Location 129
=
Discharge Canal Entrance to Lake Norman (0.51 mi. ENE)
Location 137
=
Pinnacle Access Area (12.0 mi. N)
A.8 SHORELINE SEDIMENT Semiannual samples were collected and a gamma analysis was performed on each following the drying and removal of rocks and clams. The samples were collected from the locations listed below.
Location 129
=
Discharge Canal Entrance to Lake Norman (0.51 mi. ENE)
Location 130
=
Highway 73 Bridge Downstream (0.52 mi. SW)
Location 137
=
Pinnacle Access Area (12.0 mi. N) -
A.9 DIRECT GAMMA RADIATION (TLD)
Thermoluminescent dosimeters (ILD) were collected quarterly at forty-one locations. A gamma exposure rate was determined for each TID. TLD locations are listed in Table 2.1-B. The TLDs were placed as indicated below.
An inner ring of 14 TLDs at the site boundary, one in each available meteorological sector.
The site boundary locations in the N and NNW sectors are over water; however, two special interest TLD's were placed in these sectors inside the site boundary in March, 1991.
An outer ring of 16 TLDs, one in each meteorological sector in the 6 to 8 kilometer range.
The remaining TLDs were placed in special interest areas such as population centers, residential areas, schools, and control locations.
Appendix A - Page 5
A.10 ANNUAL LAND USE CENSUS An annual Land Use Census was conducted to identify within a distance of 8 kilometers (5.0 miles) from the station, the nearest location from the site boundary in each of the sixteen meteorological sectors, the following:
The Nearest Residence The Nearest Meat Animal The Nearest Garden greater than 50 square meters or 500 square feet The Nearest Milk-giving Animal (cow, goat, etc.)
The census was conducted during the growing season from 6/2 to 6/4/2003, and 8/19/2003. Results are shown in Table 3.10. No changes were made to the sampling procedures during 2003 as a result of the 2003 census.
In the environmental program, the air deposition parameters (D/Q) are used to determine air, broadleaf vegetation and milk sampling locations. McGuire's sectors with the three highest values did not change in 2003.
V.
GLOBAL POSITIONING SYSTEM (GPS) ANALYSIS McGuire Nuclear station Radiological Environmental Monitoring Program (REMP) locations were verified using global positioning system (GPS) technology during the summer of 2003. Most GPS measurements were taken during June, 2003 through July, 2003. All current REMP sample locations were measured. Historical locations (i.e. no longer in service) were not measured during this evaluation.
Additionally, all 2003 McGuire land use census items of interest were measured. GPS equipment was utilized to determine the distance and sector from the McGuire site centerline to the nearest residence, milk animal, meat animal, and garden in each of the sixteen meteorological sectors.
Prior to this evaluation, PIP 0-02-06264 was generated as the result of an NRC (Nuclear Regulatory Commission) inspection which included the use of a GPS unit by the NRC inspector. The inspector measured a TLD site (Oconee site 056) and a discrepancy was observed. The PIP generated required that all locations be measured using standard GPS parameters and methodologies.
The McGuire site centerline used for all GPS measurements was referenced from the McGuire Nuclear Station Updated Final Safety Analysis Report (UFSAR), section 2.1.1, Appendix A - Page 6
Site Location. Waypoint coordinates used for MNS GPS measurements were latitude 350-25'-59"N and longitude 80'-56'-55"W. Maps and tables were generated using North American Datum (NAD) 27. Data normally reflect accuracy to within 2 to 5 meters from point of measurement.
All GPS field measurements were taken as close as possible to the item of interest. Distances for the locations are displayed using three significant figures.
Appendix A - Page 7
APPENDIX B RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
OF RESULTS 2003 Appendix B - Page I
Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station j
Location: Mecklenburg County, North Carolina Docket No. 50-369,370 Report Period: 01-JAN-2003 to 31-DEC-2003
-Medium or Type and Total Lower All Location with Highest Control
-Routine AlIndicator-AnnalMenrouin Pathway Number Limit of AnnualMean Locations-Location Report Sampled of Detection
- XName, Distance, Direction Meas.
Unit of Analyses Mean (Fraction)
- Location Mean (Fraction)
Mean (Fraction):
Measurement Performed Range.
Code Range Range Air Particulate 134 (pCi/m3)
(8.77 mi WNW)
BETA 364 1.OOE-02 1.41E-2 (312/312) 195 1.50E-2 (52152) 1.63E-2 (52/52) 0 5.66E-3 -2.82E-2 (0.19 mi N) 5.66E 2.82E-2 7.53E 3.19E-2 CS-134 364 5.OOE-02 0.00 (01312) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 364 6.00E-02 0.00 (0/312) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 1-131 364 7.00E-02 0.00 (0/312) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Report Generated @ 4/19/2004 1:51 PM Appendix B - Page 2
Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Li Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN-2003 to 31-DEC-2003 Medium or Type and Ncation with No: of Non Total Lwr All Indictor' HgetControl Routine Pathway Limit ofcations Annual Mean Number LctosLocation
'Report Sampled Detection Name, Distance, Direction Meas.
Unit of Analyses Mean (Fraction)
- .Location Mean (Fraction)
Mean (Fraction)
Measurement Performed L
Range Code Range Range Air Radioiodine 134 (pCi/m3)
(8.77 mi WNW)
CS-134 364 5.OOE-02 0.00 (0/312) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 364 6.00E-02 0.00 (0/312) 0.00 (0/52) 6.71E-3 (1/52) 0 0.00-0.00 0.00- 0.00 6.7 1E 6.7 1E-3 I-131 364 7.00E-02 0.00 (0/312) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00- 0.00 Li Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Lij L.
Li.
Lij Lij L-)
Report Generated @ 419/2004 1:51 PM Appendix B - Page 3
Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station t-Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN-2003 to 31-DEC-2003 Medium or Type and Total Lower Location with Highest No. ofNon-All Indicato,
'control Routine Pathway Number Limit of Annual Mean oction Rort Sampled of Detection Locations IName, Distance, Direction.i i-0f.
-.- ~
V
- ~:,
- Meas.
Unit of Analyses aLD\\
Mean (Fraction)
Location Mean (Fraction) -Mean (Fraction)
Measurement Performed Range.
Code Range Range Drinking Water 136 (pCi/liter)
(12.7 nil NNE)
BALA-140 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 BETA 65 4
1.70 (50152) 132 1.81 (12113) 1.52 (13/13) 0 0.74 - 3.32 (11.1 mi SSE) 0.92 - 2.64 0.87 - 2.03 CO-58 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 65 15 0.00 (0152) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 65 18 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 FE:59 65 30 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 H-3 20 2000 298 (10/16) 101 351 (4/4) 0.00 (014) 0 187 - 597 (3.31 mi E) 193 - 597 0.00 - 0.00 1-131 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00- 0.00 0.00- 0.00 0.00 - 0.00 MN-54 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 NB-95 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 65 30 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 -0.00 0.00 - 0.00 0.00 - 0.00 ZR-95 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0113) 0 0.00- 0.00 0.00- 0.00 0.00 - 0.00
'-J Mean and range based upon detectable measurements only t._
Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction) k Zero range indicates no detectable activity measurements Report Generated @ 4/19/2004 1:51 PM Appendix B - Page 4
Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Li Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN-2003 to 31-DEC-2003 No. of Non-Medium or
' Type and Total Lower Location with Highest Control R otine
'All Indicator,
-nua eaocto Reort Pathway Number Limit of atoAnnual Mean Sampled of Detection
.,Name, Distance, Direction Meas.
Unit of Analyses Mean (Fraction)
Location Mean (Fraction) Mean (Fraction)
Measurement Performed (D)
Range Code.,
Range Range Surface Water 135 (pCi/liter)
(11.9 mi N)
BALA-140 39 15 0.00 (0/26) 0.00 (0113) 0.00 (0/13) 0 0.00 - 0.00 0.00- 0.00 0.00 - 0.00 CO-58 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60.
39 15 0.00 (0/26) 0.00 (0113) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00- 0.00 CS-134 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 -0.00 0.00 -0.00 0.00 - 0.00 CS-137 39 18 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 -0.00 0.00 - 0.00 FE-59 39 30 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 H-3 12 2000 357 (7/8) 128 391 (4/4) 0.00 (0/4) 0 215 - 656 (0.45 mi NE) 241 - 656 0.00 - 0.00 1-131 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00- 0.00 0.00 - 0.00 MN-54 39 15 0.00(0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 -0.00 0.00 - 0.00 0.00 - 0.00 NB-95 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 39 30 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZR-95 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Report Generated @ 4/19/2004 1:51 PM Appendix B - Page S
Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station
_j Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN.2003 to 31-DEC-2003 No. of Non-Medium or Type and Total Lower A
n '
Location with Highest Contol Rone Pathway Number Limit of ll caton Annual Mean ocat on Rort Sampled of
'Detection Name, Distance,Direction Meas.
stance, Directio Unit of Analyses L
Mean (Fraction)
-Location
'Mean (Fraction)
Mean (Fraction)
Measurement; Performed
(
Range Code Range Range Milk 141 (pCi/liter)
(14.8 mi WNW)
BALA-140 58 15 0.00 (0131) 0.00 (0/27) 0.00 (0/27) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 58 15 0.00(0/31) 0.00 (0/27) 0.00 (0/27) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 58 18 0.00 (0/31) 0.00 (0/27) 0.00 (0/27) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 1-131 58 15 0.00 (0/31) 0.00 (0127) 0.00 (0/27) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 LET-131 58 1
0.00 (0131) 0.00 (0127) 0.00 (0127) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Report Generated @ 4/19/2004 1:52 PM Appendix B - Page 6
Environmental Radiological Monitoring Program Summary L-Facility: McGuire Nuclear Station L_,
Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN-2003 to 31-DEC-2003
. I :--X -....
- X.6 -; ::
No.: of Non-Medium or' Type and Total Lower Location with Highest No. o None AllInicto -Control Routine
- Pathway, Number Limit of AlndctrAnnual Mean Sampled '
of Detection Location Name, Distance, DirectionLocation Reort
-Nam, Ditane.
DrectonMeas.
Unit of Analyses Mean (Fraction)
Location Mean'(Fraction)
Mean (Fraction)
Measurement Performed (LLD)
Range Code Range '
Range Broadleaf 134 Vegetation (8.77 nii WNW)
(pCi/kg-wet)
CS-134 28 60 0.00 (0/21) 0.00 (o07) 0.00 (o01) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 28 80 0.00 (0/21) 0.00 (o07) 0.00 (On) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 1-131 28 60 0.00 (0/21) 0.00 (o07) 0.00 (o07) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 LU Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Report Generated @ 419192004 1:52 PM Appendix B -Page 7
Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Lj Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN-2003 to 31-DEC.2003 No. of Non-Medium or Type and Total Lower Location with Highest Control Routine
-Pathway Number Limit of Alndctr-Annual Mean ctinRpt Sape f
Dtcin Locations Lcto eot~
Sampled of Detection Name, Distance, Direction Meas.
Unit of Analyses Mean (Fraction)
Location Mean'(Fraction) Mean (Fraction)
Measurement Performed LDRange Code Range Range Food Products No Control (pCi/kg-wet)
Location CS-134 12 60 0.00 (0/12) 0.00 (0/12) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 12 80 0.00 (0/12) 0.00 (0/12) 0.00 (0/0) 0 0.00-0.00 0.00- 0.00 0.00- 0.00 1-131 12 60 0.00 (0/12) 0.00 (0/12) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Report Generated @ 4/19/2004 1:52 PM Appendix B - Page 8
Environmental Radiological Monitoring Program Summary L-Facility: McGuire Nuclear Station Lj Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN-2003 to 31-DEC-2003 No'. of Nor-Medium or Type and Total Lower A
n :'
ocation with Highest C
Routine Pathway Number Limit of Annual Mean Loction Rort Sampled of Detection Loctions Name, Distance, Direction Meas.
0 X
- M eas.
Unit of Analyses Mean (Fraction) _
Location Mean (Fraction) Mean (Fraction)
- Measurement Performned (L
)
Range Code Range Range Fish 137 (pCi/kg-wet)
(12.0 rni N)
CO-58 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00- 0.00 0.00- 0.00 0.00 - 0.00 CS-134 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 12 150 30.5 (2/6) 129 30.5 (2/6) 0.00 (0/6) 0 17.6 - 43.4 (0.51 mi ENE) 17.6 - 43.4 0.00 - 0.00 FE-59 12 260 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00- 0.00 0.00 - 0.00 ZN-65 12 260 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Report Generated @ 4119t2004 1:52 PM Appendix B - Page 9
Environmental Radiological Monitoring Program Summary Li Facility: McGuire Nuclear Station k.J Location: Mecklenburg County, North Carolina Docket No.
50-369,370 Report Period: 01-JAN-2003 to 31-DEC-2003 No. of Non-Medium or Type and Total Lower Al
.ndicator Location with Highest C
Routine
'Pathway Number Limit of locaton Annual Mean Rort Sampled of Detection t
Name,Distance, Direction Loatio Meas.
Unit of Analyses Mean (Fraction)
Location Mean (Fraction)
Mean (Fraction)
Measurement Performed LD)
Range. -
Code'.
Range
- Range Shoreline 137 Sediment (12.0 mi N)
(pCi/kg-dry)
MN-54 6
0 0.00 (014) 0.00 (012) 0.00 (0/2) 0.00 - 0.00 0.00- 0.00 0.00 - 0.00 CO-58 6
0 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0 0.00 - 0.00 0.00- 0.00 0.00 - 0.00 CO-60 6
0 0.00 (014) 0.00 (02) 0.00 (0/2) 0 0.00- 0.00 0.00- 0.00 0.00 - 0.00 CS-134 6
150 0.00 (0/4) 0.00 (012) 0.00 (0/2) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 6
180 72.4 (3/4) 129 111(1/2) 0.00 (0/2) 0 40.0- 111 (0.51 miENE) 111 -111 0.00- 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements If LLD is equal to 0.00, then the LLD is not required by Selected Licensee Commitments Report Generated @ 4/19/2004 1:52 PM Appendix B - Page 10
Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Location: Mecklenburg County, North Carolina Docket No.
50369,370 Report Period: 01-JAN-2003 to 31-DEC-2003 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)
Zero range indicates no detectable activity measurements Report Generated @ 4119/2004 1:52 PM Appendix B - Page 11
APPENDIX C SAMPLING DEVIATIONS UNAVAILABLE ANALYSES Appendix C - Page I
APPENDIX C MCGUIRE NUCLEAR STATION SAMPLING DEVIATIONS & UNAVAILABLE ANALYSES DEVIATION & UNAVAILABLE REASON CODES BF Blown Fuse PO Power Outage FZ Sample Frozen PS Pump out of service Undergoing Repair IW Inclement Weather SL Sample Loss/Lost due to Lab Accident LC Line Clog to Sampler SM Motor / Rotor Seized OT Other TF Torn Filter PI Power Interrupt VN Vandalism PM Preventive Maintenance C.1 SAMPLING DEVIATIONS Surface Water Scheduled Actual Reason Location Collection Dates Collection Dates Code-V.' -
Corrective Action Sampling equipment did not operate properly during first half of composite period due to low water pressure. Water pressure was adjusted and normal 135 10/1 - 10/29/03 10/1 - 10/29103 OT sampling resumed 10/15/03.
TLD Scheduled Actual
-'Reason Location CollectionDates Collection Dates-'_-7-Code-Corrective Action The 4 quarter TLD was collected on 1/20/04. The TLD was not collected on the scheduled date due to a collection 157 9/18-12/18/03 9/18 - 1/20/04 OT error.
C.2 UNAVAILABLE ANALYSES TLD
-Scheduled Reason:
Location Collection Dates
-Code Corrective Action' 178 3/20 - 6/19103 OT TLD missing. 3m" quarter TLD placed in field.
143 9/18 - 12/18/03 OT l TLD missing. 1" quarter 2004 TLD placed in field.
171 9/18 - 12/18/03 VN TLD missing. 1 quarter 2004 TLD placed in field.
Appendix C - Page 2
APPENDIX D ANALYTICAL DEVIATIONS No Analytical deviations were incurred for the 2003 Radiological Environmental Monitoring Program Appendix D - Page 1
APPENDIX E RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM RESULTS This appendix includes all of the sample analysis reports generated from each sample medium for 2003. Appendix E is located separately from this report and is permanently archived at Duke Power Company's Environmental Center radiological environmental master file, located at the McGuire Nuclear Station Site in Huntersville, North Carolina.
Appendix E - Page I