Annual Radiological Environmental Operating Report
ML11143A119
Person / Time
Site: McGuire, Mcguire  
Issue date: 12/31/2010
From:
Duke Energy Carolinas
To:
Office of Nuclear Reactor Regulation
References
Download: ML11143A119 (88)


Text

ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT DUKE ENERGY CORPORATION MCGUIRE NUCLEAR STATION Units 1 and 2 2010

i TABLE OF CONTENTS 1.0 Executive Summary.

1-1 2.0 Introduction 2-1 2.1 Site Description and Sample Locations 2-1 2.2 Scope and Requirements of the REMP 2-1 2.3 Statistical and Calculational Methodology.

2-2 2.3.1 Estimation of the Mean Value.

2-2 2.3.2 Lower Level of Detection and Minimum Detectable Activity.

2-3 2.3.3 Trend Identification.

2-3 3.0 Interpretation of Results.

3-1 3.1 Airborne Radioiodine and Particulates 3-2 3.2 Drinking Water.

3-5 3.3 Surface Water.

3-7 3.4 Milk.

3-9 3.5 Broadleaf Vegetation.

3-10 3.6 Food Products.

3-11 3.7 Fish.

3-12 3.8 Shoreline Sediment.

3-15 3.9 Direct Gamma Radiation.

3-18 3.9.1 Environmental TLD.

3-18 3.9.2 ISFSI 3-18 3.10 Land Use Census 3-20 4.0 Evaluation of Dose.

4-1 4.1 Dose from Environmental Measurements.

4-1 4.2 Estimated Dose from Releases.

4-1 4.3 Comparison of Doses.

4-2 5.0 Quality Assurance 5-1 5.1 Sample Collection 5-1 5.2 Sample Analysis 5-1 5.3 Dosimetry Analysis.

5-1 5.4 Laboratory Equipment Quality Assurance.

5-1 5.4.1 Daily Quality Control 5-1 5.4.2 Calibration Verification.

5-1 5.4.3 Batch Processing 5-2 5.5 Duke Energy Intercomparison Program 5-2 5.6 ERA Proficiency Testing.

5-2 5.7 Duke Energy Audits.

5-2 5.8 U.S. Nuclear Regulatory Commission Inspections 5-2 5.9 State of North Carolina Intercomparison Program

. 5-2 5.10 TLD Intercomparison Program.

5-3 5.10.1 Nuclear Technology Services Intercomparison Program.

5-3 5.10.2 Internal Crosscheck (Duke Energy).

5-3 6.0 References 6-1

ii Appendices Appendix A: Environmental Sampling and Analysis Procedures A-1 I.

Change of Sampling Procedures A-2 II. Description of Analysis Procedures.

A-2 III. Change of Analysis Procedures.

A-3 IV. Sampling and Analysis Procedures A-3 A.1 Airborne Particulate and Radioiodine A-3 A.2 Drinking Water A-3 A.3 Surface Water.

A-4 A.4 Milk A-4 A.5 Broadleaf Vegetation A-4 A.6 Food Products.

A-4 A.7 Fish A-5 A.8 Shoreline Sediment.

A-5 A.9 Direct Gamma Radiation (TLD)

A-5 A.10 Annual Land Use Census A-5 V. Global Positioning System (GPS) Analysis.

A-6 Appendix B: Radiological Env. Monitoring Program - Summary of Results B-1 Air Particulate.

B-2 Air Radioiodine.

B-3 Drinking Water.

B-4 Surface Water.

B-5 Milk.

B-6 Broadleaf Vegetation B-7 Food Products.

B-8 Fish.

B-9 Shoreline Sediment.

B-10 Direct Gamma Radiation (TLD)

B-11 Appendix C: Sampling Deviations and Unavailable Analyses C-1 C.1 Sampling Deviations C-2 C.2 Unavailable Analyses C-3 Appendix D: Analytical Deviations.

D-1 Appendix E: Radiological Environmental Monitoring Program Results E-1 LIST OF FIGURES 2.1-1 Sampling Locations Map (0.5 Mile Radius) 2-4 2.1-2 Sampling Locations Map (Ten Mile Radius) 2-5 3.1 Concentration of Gross Beta in Air Particulate.

3-3 3.2 Concentration of Tritium in Drinking Water 3-5 3.3 Concentration of Tritium in Surface Water.

3-7 3.7-1 Concentration of Cs-137 in Fish 3-13 3.7-2 Concentration of Co-60 in Fish.

3-13 3.8-1 Concentration of Cs-137 in Shoreline Sediment.

3-15 3.8-2 Concentration of Co-60 in Shoreline Sediment.

3-16 3.9-1 Direct Gamma Radiation (TLD) Results 3-19 3.9-2 McGuire Inner Ring (TLD) Results.

3-21 3.9-3 McGuire Outer Ring (TLD) Results.

3-22 3.10 2010 Land Use Census Map 3-24 LIST OF TABLES 2.1-A Radiological Monitoring Program Sampling Locations 2-6 2.1-B Radiological Monitoring Program Sampling Locations (TLD Sites) 2-7

iii 2.2-A Reporting Levels for Radioactivity Concentrations in Environmental Samples 2-8 2.2-B REMP Analysis Frequency 2-8 2.2-C Maximum Values for the Lower Limits of Detection.

2-9 3.1-A Mean Concentrations of Radionuclides in Air Particulate.

3-3 3.1-B Mean Concentrations of Air Radioiodine (I-131) 3-4 3.2 Mean Concentrations of Radionuclides in Drinking Water.

3-6 3.3 Mean Concentrations of Tritium in Surface Water 3-8 3.4 Mean Concentrations of Cs-137 in Milk 3-9 3.5 Mean Concentrations of Cs-137 in Broadleaf Vegetation.

3-10 3.6 Mean Concentrations of Cs-137 in Food Products 3-11 3.7 Mean Concentrations of Radionuclides in Fish (pCi/kg) 3-14 3.8 Mean Concentrations of Radionuclides in Shoreline Sediment (pCi/kg) 3-16 3.9-A Direct Gamma Radiation (TLD) Results 3-20 3.9-B Direct Gamma Radiation (TLD) Results Inner Ring.

3-21 3.9-C Direct Gamma Radiation (TLD) Results Outer Ring.

3-22 3.10 McGuire 2010 Land Use Census Results.

3-23 4.1-A 2010 Environmental and Effluent Dose Comparison.

4-3 4.1-B Maximum Individual Dose for 2010 based on Environmental Measurements for McGuire Nuclear Station 4-5 5.0-A 2010 Cross-Check Results for EnRad Laboratories 5-4 5.0-B 2010 Environmental Resource Associates QuikTM Response Program.

5-9 5.0-C 2010 Environmental Dosimeter Cross-Check Results.

5-11 LIST OF ACRONYMS USED IN THIS TEXT (in alphabetical order)

BW BiWeekly C

Control DEHNR Department of Environmental Health and Natural Resources DHEC Department of Health and Environmental Control EPA Environmental Protection Agency ERA Environmental Resource Associates GI-LLI Gastrointestinal - Lower Large Intestine GPS Global Positioning System ISFSI Independent Spent Fuel Storage Installation LLD Lower Limit of Detection M

Monthly MDA Minimum Detectable Activity MNS McGuire Nuclear Station mrem millirem NIST National Institute of Standards and Technology NRC Nuclear Regulatory Commission ODCM Offsite Dose Calculation Manual pCi/kg picocurie per kilogram pCi/l picocurie per liter pCi/m3 picocurie per cubic meter PIP Problem Investigation Program Q

Quarterly REMP Radiological Environmental Monitoring Program SA Semiannually SLCs Selected Licensee Commitments SM Semimonthly TECH SPECs Technical Specifications TLD Thermoluminescent Dosimeter

Ci/ml microcurie per milliliter UFSAR Updated Final Safety Analysis Report W

Weekly

Section 1 - Page 1 1.0 EXECUTIVE

SUMMARY

This Annual Radiological Environmental Operating Report describes the McGuire Nuclear Station Radiological Environmental Monitoring Program (REMP), and the program results for the calendar year 2010.

Included are the identification of sampling locations, descriptions of environmental sampling and analysis procedures, comparisons of present environmental radioactivity levels and pre-operational environmental data, comparisons of doses calculated from environmental measurements and effluent data, analysis of trends in environmental radiological data as potentially affected by station operations, and a summary of environmental radiological sampling results. Quality assurance practices, sampling deviations, unavailable samples, and program changes are also discussed.

Sampling activities were conducted as prescribed by Selected Licensee Commitments (SLCs). Required analyses were performed and detection capabilities were met for all collected samples as required by SLCs. Eleven-hundred forty-five samples were analyzed comprising 1,607 test results in order to compile data for the 2010 report.

Based on the annual land use census, the current number of sampling sites for McGuire Nuclear Station is sufficient.

Concentrations observed in the environment in 2010 for station related radionuclides were generally within the ranges of concentrations observed in the past.

Inspection of data showed that radioactivity concentrations in surface water, drinking water, shoreline sediment and fish are higher than the activities reported for samples collected prior to the operation of the station. Measured concentrations were not higher than expected, and all positively identified measurements were within limits as specified in SLCs.

Additionally, environmental radiological monitoring data is consistent with effluents introduced into the environment by plant operations. The total body dose estimated to the maximum exposed member of the public as calculated by environmental sampling data, excluding TLD results, was 7.91E-2 mrem for 2010. It is therefore concluded that station operations has had no significant radiological impact on the health and safety of the public or the environment.

Section 2 - Page 1

2.0 INTRODUCTION

2.1 SITE DESCRIPTION AND SAMPLE LOCATIONS McGuire Nuclear Station (MNS) is located geographically near the center of a highly industrialized region of the Carolinas. The land is predominantly rural non-farm with a small amount of land being used for farming. The McGuire site is in northwestern Mecklenburg County, North Carolina, 17 miles north-northwest of Charlotte, North Carolina. The site is bounded to the west by the Catawba River channel and to the north by 32,510 acre Lake Norman. Lake Norman is impounded by Duke Energy Corporation's Cowans Ford Dam Hydroelectric Station. The tailwater of Cowans Ford Dam is the upper limit of Mountain Island Reservoir. Mountain Island Dam is located 15 miles downstream from the site. Lookout Shoals Hydroelectric Station is at the upper reaches of Lake Norman. Marshall Steam Station is located on the western shore of Lake Norman, approximately 16 miles upstream from the site (reference 6.3).

MNS consists of two pressurized water reactors. Each reactor unit is essentially a mirror image of the other joined by an auxiliary building housing both separate and common equipment. Each unit was designed to produce approximately 1200 gross Megawatts of electricity. Unit 1 achieved criticality August 8, 1981 and Unit 2 on May 8, 1983.

Figures 2.1-1 and 2.1-2 are maps depicting the Thermoluminescent Dosimeter (TLD) monitoring locations and the sampling locations. The location numbers shown on these maps correspond to those listed in Tables 2.1-A and 2.1-B. Figure 2.1-1 comprises all sample locations within 0.5 mile radius of MNS. Figure 2.1-2 comprises all sample locations within a ten mile radius of MNS.

2.2 SCOPE AND REQUIREMENTS OF THE REMP An environmental monitoring program has been in effect at McGuire Nuclear Station since 1977, four years prior to operation of Unit 1 in 1981. The preoperational program provides data on the existing environmental radioactivity levels for the site and vicinity which may be used to determine whether increases in environmental levels are attributable to the station. The operational program provides surveillance and backup support of detailed effluent monitoring which is necessary to evaluate the significance, if any, of the contributions to the existing environmental radioactivity levels that result from station operation.

This monitoring program is based on NRC guidance as reflected in the Selected Licensee Commitments Manual, with regard to sample media, sampling locations, sampling frequency, and analytical sensitivity requirements. Indicator and control locations were established for comparison purposes to distinguish radioactivity of station origin from natural or other man-made environmental radioactivity. The environmental monitoring program also verifies projected and anticipated radionuclide concentrations in the environment and related exposures from releases of radionuclides from McGuire Nuclear Station. This program satisfies the

Section 2 - Page 2 requirements of Section IV.B.2 of Appendix I to 10CFR50 and provides surveillance of all appropriate critical exposure pathways to man and protects vital interests of the company, public, and state and federal agencies concerned with the environment. Reporting levels for radioactivity found in environmental samples are listed in Table 2.2-A. Table 2.2-B lists the REMP analysis and frequency schedule.

The Annual Land Use Census, required by Selected Licensee Commitments, is performed to ensure that changes in the use of areas at or beyond the site boundary are identified and that modifications to the Radiological Environmental Monitoring Program are made if required by changes in land use. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10CFR50. Results are shown in Table 3.10.

Participation in an interlaboratory comparison program as required by Selected Licensee Commitments provides for independent checks on the precision and accuracy of measurements of radioactive material in REMP sample matrices. Such checks are performed as part of the quality assurance program for environmental monitoring in order to demonstrate that the results are valid for the purposes of Section IV.B.2 of Appendix I to 10CFR50. A summary of the results obtained as part of this comparison program are in Section 5 of this annual report.

2.3 STATISTICAL AND CALCULATIONAL METHODOLOGY 2.3.1 ESTIMATION OF THE MEAN VALUE There was one (1) basic statistical calculation performed on the raw data resulting from the environmental sample analysis program. The calculation involved the determination of the mean value for the indicator and the control samples for each sample medium. The mean is a widely used statistic. This value was used in the reduction of the data generated by the sampling and analysis of the various media in the Radiological Environmental Monitoring Program. Net activity (or concentration)" is the activity (or concentration) determined to be present in the sample. No "Minimum Detectable Activity", "Lower Limit of Detection", "Less Than Level", or negative activities or concentrations are included in the calculation of the mean. The following equation was used to estimate the mean (reference 6.8):

x

=

N N

i ix



1 Where:

x = estimate of the mean, i = individual sample, N = total number of samples with a net activity (or concentration),

i = net activity (or concentration) for sample i.

Section 2 - Page 3 2.3.2 LOWER LEVEL OF DETECTION AND MINIMUM DETECTABLE ACTIVITY The Lower Level of Detection (LLD) and Minimum Detectable Activity (MDA) are used throughout the Environmental Monitoring Program.

LLD - The LLD, as defined in the Selected Licensee Commitments Manual is the smallest concentration of radioactive material in a sample that will yield a net count, above the system background, that will be detected with 95% probability with only 5%

probability of falsely concluding that a blank observation represents a "real" signal. The LLD is an a priori lower limit of detection. The actual LLD is dependent upon the standard deviation of the background counting rate, the counting efficiency, the sample size (mass or volume), the radiochemical yield, and the radioactive decay of the sample between sample collection and counting. The "required" LLD's for each sample medium and selected radionuclides are given in the Selected Licensee Commitments and are listed in Table 2.2-C.

MDA - The MDA is the net counting rate (sample after subtraction of background) that must be surpassed before a sample is considered to contain a scientifically measurable amount of a radioactive material exceeding background amounts. The MDA is calculated using a sample background and may be thought of as an "actual" LLD for a particular sample measurement.

2.3.3 TREND IDENTIFICATION One of the purposes of an environmental monitoring program is to determine if there is a buildup of radionuclides in the environment due to the operation of the nuclear station.

Visual inspection of tabular or graphical presentations of data (including preoperational) is used to determine if a trend exists. A decrease in a particular radionuclide's concentration in an environmental medium does not indicate that reactor operations are removing radioactivity from the environment but that reactor operations are not adding that radionuclide to the environment in quantities exceeding the preoperational level and that the normal removal processes (radioactive decay, deposition, resuspension, etc.) are influencing the concentration.

Substantial increases or decreases in the amount of a particular radionuclide's release from the nuclear plant will greatly affect the resulting environmental levels; therefore, a knowledge of the release of a radionuclide from the nuclear plant is necessary to completely interpret the trends, or lack of trends, determined from the environmental data. Some factors that may affect environmental levels of radionuclides include prevailing weather conditions (periods of drought, solar cycles or heavier than normal precipitation), construction in or around either the nuclear plant or the sampling location, and addition or deletion of other sources of radioactive materials (such as the Chernobyl accident). Some of these factors may be obvious while others are sometimes unknown.

Therefore, how trends are identified will include some judgment by plant personnel.

Section 2 - Page 4 Figure 2.1-1

u ~ a...,

ua.::!E1J

J E.. !9 Zt<lC LL 000.

z I

j o s !,

J o

Section 2 - Page 5 Figure 2.1-2 Other Sampling Locations 175 (15.5mi. WNW)

... 141 Catawba County

~

~-

177.

McGuire Nuclear Station Sampling Locations Map (Ten Mile Radius)

Legend TLD Locations All Other locations

/'V Public Roads r./ Rail Roads

/ **.** /

County Boundary Incorporated Areas Water Approxim,l1e k>cation olleat.. es shown o

2 3 Miles Prc;edion NCSP NA021

Section 2 - Page 6 TABLE 2.1-A MCGUIRE RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS Table 2.1-A Codes W

Weekly SM Semimonthly BW BiWeekly Q

Quarterly M

Monthly SA Semiannually C

Control I

Indicator Site Measure Type Location Description*

Air Rad.

& Part.

Surface Water Drinking Water Shoreline Sediment Food Products Fish Milk Broad Leaf Veg.

101 I

North Mecklenburg Water Treatment Facility ( 3.31 mi E )

M 102 C

Amity Church Road ( 9.89 mi WNW )

W M ( b )

103 I

Cottonwood Substation ( 4.20 mi NE )

W 119 I

Mt. Holly Municipal Water Supply

( 7.40 mi SSW )

M 120 I

Site Boundary ( 0.46 mi NNE )

W M ( b )

121 I

Site Boundary ( 0.47 mi NE )

W 125 I

Site Boundary ( 0.38 mi SW )

W M ( b )

128 I

Discharge Canal Bridge ( 0.45 mi NE )

M 129 I

Discharge Canal Entrance to Lake Norman

( 0.51 mi ENE )

SA SA 130 I

Hwy 73 Bridge Downstream

( 0.52 mi SW )

SA 131 I

Cowans Ford Dam ( 0.64 mi WNW )

M 132 I

Charlotte Municipal Water Supply

( 11.1 mi SSE )

M 133 I

Cornelius ( 6.23 mi ENE )

W 135 C

Plant Marshall Intake Canal ( 11.9 mi N )

M 136 C

Mooresville Municipal Water Supply

( 12.7 mi NNE )

M 137 C

Pinnacle Access Area ( 12.0 mi N )

SA SA 141 C

Lynch Dairy-Cows ( 14.8 mi WNW )

SM 188 I

5 mile radius Gardens ( 2.79 mi NNE )

M (a )

193 I

Site Boundary ( 0.19 mi N )

M ( b )

194 I

East Lincoln County Water Supply

( 6.73 mi NNW )

M 195 I

Fishing Access Road ( 0.19 mi N )

W (a) During Harvest Season (b) When Available

  • GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.

Section 2 - Page 7 TABLE 2.1-B MCGUIRE RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS (TLD SITES)

Table 2.1-B Codes IR Inner Ring OR Outer Ring C

Control SI Special Interest Site Measure Type Location Distance*

(miles)

Sector Site Measure Type Location Distance*

(miles)

Sector 143 IR SITE BOUNDARY 0.27 NW 164 OR HAMBRIGHT &

BEATTIES FORD ROAD 4.64 SSE 144 IR SITE BOUNDARY 0.46 NNE 165 OR ARTHER AUTEN ROAD 4.57 S

145 IR SITE BOUNDARY 0.47 NE 166 OR NECK ROAD REFUGE BOUNDARY 4.44 SSW 146 IR SITE BOUNDARY 0.42 ENE 167 OR LUCIA RIVERBEND HWY/OLD FIREHOUSE 4.87 SW 147 IR SITE BOUNDARY 0.44 E

168 OR OLD PLANK ROAD BRIDGE 4.60 WSW 148 IR SITE BOUNDARY 0.46 ESE 169 OR GLOVER LANE 4.03 W

149 IR SITE BOUNDARY 0.50 SE 170 OR LITTLE EGYPT ROAD 4.32 WNW 151 IR SITE BOUNDARY 0.37 S

171 OR TRIANGLE ACE HARDWARE 3.95 NW 152 IR SITE BOUNDARY 0.44 SSW 172 OR LAKESHORE S RD ISLAND VIEW COURT 4.69 NNW 153 IR SITE BOUNDARY 0.47 SW 173 SI KEISTLER STORE /

GLENWOOD ROAD 8.39 NNW 154 IR SITE BOUNDARY 0.45 W

174 SI EAST LINCOLN JR.

HIGH SCHOOL 8.77 WNW 156 IR SITE BOUNDARY 0.44 WNW 175 C

BOGER CITY 15.5 WNW 189 IR SITE BOUNDARY 0.43 SSE 177 SI BELMARROW RD /

COULWOOD 8.77 S

190 IR SITE BOUNDARY 0.37 WSW 178 SI FLORIDA STEEL CORPORATION 9.36 SE 157 IR THE POINTE (MOORESVILLE) 4.69 N

180 SI MOORESVILLE WATER TREATMENT FACILITY 12.7 NNE 158 OR BETHEL CHURCH RD 4.33 NNE 181 SI OLD DAVIDSON WATER FACILITY 7.02 NE 159 OR HENDERSON ROAD &

W CATAWBA AVENUE 4.73 NE 182 SI CORNELIUS AIR SITE # 133 6.23 ENE 160 OR ANCHORAGE MARINE SHOWROOM 4.89 ENE 186 SI MCGUIRE FISHING ACCESS ROAD 0.24 NNW 161 OR SAM FURR ROAD

& HWY 21 4.70 E

187 SI ENERGY EXPLORIUM /

AIR SITE # 195 0.19 N

162 OR RANSON ROAD 4.53 ESE 191 SI PENINSULA DEVELOPMENT 2.84 NNE 163 OR MCCOY ROAD 4.94 SE

  • GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.

Section 2 - Page 8 TABLE 2.2-A REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES Analysis Water (pCi/liter)

Air Particulates or Gases (pCi/m3)

Fish (pCi/kg-wet)

Milk (pCi/liter)

BroadLeaf Vegetation (pCi/kg-wet)

H-3 20,000(a),(b)

Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400 I-131 2

0.9 3

100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 300 (a) If no drinking water pathway exists, a value of 30,000 pCi/liter may be used.

(b) H-3 Reporting level not applicable to surface water TABLE 2.2-B REMP ANALYSIS FREQUENCY Sample Medium Analysis Schedule Gamma Isotopic Tritium Low Level I-131 Gross Beta TLD Air Radioiodine Weekly X

Air Weekly X

X Direct Radiation Quarterly X

Surface Monthly Composite X

Water Quarterly Composite X

Drinking Monthly Composite X

(a)

X Water Quarterly Composite X

Shoreline Sediment Semiannually X

Milk Semimonthly X

X Fish Semiannually X

Broadleaf Vegetation Monthly(b)

X Food Products Monthly(b)

X (a) Low-level I-131 analysis will be performed if the dose calculated for the consumption of drinking water is > 1 mrem per year. An LLD of 1 pCi/liter will be required for this analysis.

(b) When Available

Section 2 - Page 9 TABLE 2.2-C MAXIMUM VALUES FOR THE LOWER LIMITS OF DETECTION Analysis Water (pCi/liter)

Air Particulates or Gases (pCi/m3)

Fish (pCi/kg-wet)

Milk (pCi/liter)

BroadLeaf Vegetation (pCi/kg-wet)

Sediment (pCi/kg-dry)

Gross Beta 4

0.01 H-3 2000 (a)

Mn-54 15 130 Fe-59 30 260 Co-58, 60 15 130 Zn-65 30 260 Zr-Nb-95 15 I-131 1(b) 0.07 1

60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-La-140 15 15 (a) If no drinking water pathway exists, a value of 3000 pCi/liter may be used.

(b) If no drinking water pathway exists, the LLD of gamma isotopic analysis may be used.

Section 3 - Page 1 3.0 INTERPRETATION OF RESULTS Review of 2010 REMP analysis results was performed to detect and identify changes in environmental levels as a result of station operation. The radionuclides with Selected Licensee Commitments reporting levels that indicate consistent detectable activity have been historically trended from preoperation to present. Analyses from 1977 - 1978 have been excluded since these results were much higher than the other preoperational years due to outside influences such as weapons testing. The preoperational analyses from 1981 were combined with the operational analyses from the latter part of 1981 and averaged to give one concentration for each radionuclide for that year.

The highest annual mean concentration of applicable Selected Licensee Commitments radionuclides from the indicator locations for each media type was used for trending purposes.

Trending was performed by comparing annual mean concentrations to historical results. Factors evaluated include the frequency of detection and the concentration in terms of the percent of the radionuclides SLC reporting level (Table 2.2-A). All maximum percent of reporting level values were well below the 100% action level. The highest value reached during 2010 was 3.60% for drinking water tritium at the North Mecklenburg Water Treatment Facility (Location 101). Only Selected Licensee Commitments radionuclides were detected in 2010.

Changes in sample location, analytical technique, and presentation of results must be considered when reviewing for trends. Calculation of the annual mean concentrations has been performed differently over the history of the REMP. During 1979-1986, all net results (sample minus background) positive and negative, were included in the calculation of the mean. Only positive net activity results were used to calculate the mean for the other years. All negative values were replaced with a zero for calculational and graphical purposes to properly represent environmental conditions. A change in gamma spectroscopy analysis systems in 1987 ended a period when many measurements yielded detectable low-level activity for both indicator and control location samples. It is possible that the method the previous system used to estimate net activity may have been vulnerable to false-positive results.

This section includes tables and graphs containing the highest annual mean concentrations of any effluent related radionuclide detected since the change in analysis systems in 1987. Any zero concentrations used in tables or graphs represent activity measurements less than detectable levels. Only the specific radionuclides that represent the highest dose contributors or demonstrate consistent detectable activity are shown graphically.

Data presented in Sections 3.1 through 3.9 support the conclusion that there was no significant increase in radioactivity in the environment around McGuire Nuclear Station due to station operations in 2010. Similarly, there was no significant increase in ambient background radiation levels in the surrounding areas. The 2010 land use census data, shown in Section 3.10, indicates that no program changes are required as a result of the census.

Section 3 - Page 2 3.1 AIRBORNE RADIOIODINE AND PARTICULATES In

2010, 371 particulate and radioiodine samples were analyzed, 318 at six indicator locations and 53 at the control location. Particulate samples were analyzed weekly for gamma and gross beta. Radioiodine samples received a weekly gamma analysis.

Gross beta analyses indicated 2.01E-2 pCi/m3 at the location with the highest annual mean and 1.95E-2 pCi/m3 at the control location. The control location was relocated during 2008 (reference 6.14). Detectable gamma emitting particulate activity (Co-58) was last observed in environmental air particulate samples in 2004 (reference 6.15).

No detectable I-131 activity in any environmental air radioiodine samples was found in 2010. K-40 and Be-7 that occur naturally were routinely detected in charcoal cartridges collected during the year. Cs-137 activity was not detected on any cartridges in 2010. Cs-137 detection on the charcoal cartridge was determined in 1990 to be an active constituent of the charcoal. A similar study was performed in 2001 again yielding this conclusion. Therefore, any Cs-137 activities were not used in any dose calculations in Section 4.0 of this report.

Figure 3.1 shows gross beta highest annual mean indicator and control location concentrations since 1985. There is no reporting level for gross beta. Table 3.1-A shows indicator and control location highest annual means for Cs-137 and gross beta.

Table 3.1-B gives indicator location highest annual means and control means since 1979 for I-131. Preoperational and ten year averages are also shown. No I-131 activity has been detected since 1989. Since no activity was detected in 2010, no reporting levels were approached.

Section 3 - Page 3 Figure 3.1 0.00E+00 1.00E02 2.00E02 3.00E02 4.00E02 5.00E02 6.00E02 7.00E02 8.00E02 9.00E02 1.00E01 1985 1988 1991 1994 1997 2000 2003 2006 2009 ConcentrationofGrossBetainAirParticulate IndicatorLocation ControlLocation pCi/m3 There is no reporting level for Gross Beta in air particulate Table 3.1-A Mean Concentrations of Radionuclides in Air Particulate YEAR Cs-137 Indicator (pCi/m3)

Cs-137 Control (pCi/m3)

Beta Indicator (pCi/m3)

Beta Control (pCi/m3) 1979*

4.40E-3 1.47E-3 1980*

6.70E-3 4.53E-3 1981*

6.16E-3 5.32E-3 1982*

3.82E-3 2.29E-3 1983*

2.93E-3 3.21E-3 1984 1.74E-3 8.29E-4 1985 1.86E-3 1.32E-3 2.44E-2 2.40E-2 1986 4.98E-3 3.03E-3 2.64E-2 2.52E-2 1987 1.07E-2 7.91E-3 2.54E-2 2.59E-2 1988 0.00E0 0.00E0 7.49E-2 5.51E-2 1989 0.00E0 0.00E0 2.22E-2 2.14E-2 1990 0.00E0 0.00E0 2.58E-2 2.37E-2 1991 0.00E0 0.00E0 2.16E-2 2.15E-2 1992 0.00E0 0.00E0 1.92E-2 2.02E-2 1993 0.00E0 0.00E0 1.93E-2 2.04E-2 1994 0.00E0 0.00E0 2.28E-2 2.02E-2 1995 0.00E0 0.00E0 3.02E-2 5.17E-2 1996 0.00E0 0.00E0 3.11E-2 5.49E-2 1997 0.00E0 0.00E0 2.34E-2 3.62E-2 1998 0.00E0 0.00E0 1.86E-2 2.66E-2 1999 0.00E0 0.00E0 2.06E-2 3.47E-2 2000 0.00E0 0.00E0 2.00E-2 2.77E-2 2001 0.00E0 0.00E0 1.79E-2 1.91E-2

Section 3 - Page 4 Table 3.1-A continued YEAR Cs-137 Indicator (pCi/m3)

Cs-137 Control (pCi/m3)

Beta Indicator (pCi/m3)

Beta Control (pCi/m3) 2002 0.00E0 0.00E0 1.57E-2 1.72E-2 2003 0.00E0 0.00E0 1.50E-2 1.63E-2 2004 0.00E0 0.00E0 1.67E-2 1.71E-2 2005 0.00E0 0.00E0 1.68E-2 1.77E-2 2006 0.00E0 0.00E0 1.79E-2 1.94E-2 2007 0.00E0 0.00E0 2.12E-2 2.18E-2 2008 0.00E0 0.00E0 1.92E-2 1.93E-2 2009 0.00E0 0.00E0 1.79E-2 1.76E-2 Average (2000 - 2009)

NOT APPLICABLE NOT APPLICABLE 1.78E-2 1.93E-2 2010 0.00E0 0.00E0 2.01E-2 1.95E-2 0.00E0 = no detectable measurements

  • Radioiodine and Particulates analyzed together ** Gross Beta analysis not performed Table 3.1-B Mean Concentrations of Air Radioiodine (I-131)

Year Indicator Location (pCi/m3)

Control Location (pCi/m3) 1979*

3.28E-3 1.04E-3 1980*

2.01E-3 1.10E-3 1981*

4.17E-3 6.27E-4 1982*

1.42E-3 2.48E-3 1983*

1.99E-3 2.01E-4 1984 3.17E-3 0.00E0 1985 3.15E-3 1.04E-3 1986 1.27E-2 6.10E-3 1987 1.07E-2 6.60E-3 1988 0.00E0 0.00E0 1989 2.18E-2 0.00E0 1990 0.00E0 0.00E0 1991 0.00E0 0.00E0 1992 0.00E0 0.00E0 1993 0.00E0 0.00E0 1994 0.00E0 0.00E0 1995 0.00E0 0.00E0 1996 0.00E0 0.00E0 1997 0.00E0 0.00E0 1998 0.00E0 0.00E0 1999 0.00E0 0.00E0 2000 0.00E0 0.00E0 2001 0.00E0 0.00E0 2002 0.00E0 0.00E0 2003 0.00E0 0.00E0 2004 0.00E0 0.00E0 2005 0.00E0 0.00E0 2006 0.00E0 0.00E0 2007 0.00E0 0.00E0 2008 0.00E0 0.00E0 2009 0.00E0 0.00E0 2010 0.00E0 0.00E0 0.00E0 = no detectable measurements

  • Radioiodine and Particulate analyzed together.

Section 3 - Page 5 3.2 DRINKING WATER In 2010, 65 drinking water samples were analyzed for gross beta and gamma emitting radionuclides. Fifty-two samples were from the four indicator locations and 13 from the control location. Tritium (H-3) analyses were performed on 20 composite samples, 16 at indicator locations and four at the control location.

No detectable gamma activity was found in drinking water samples in 2010 and has not been detected since 1987. Gross beta analyses indicated 1.85 pCi/l at the location with the highest annual mean and 1.74 pCi/l at the control location. Tritium was detected in thirteen of the 16 indicator composite samples taken in 2010 with the highest annual mean resulting in only 3.60% of the reporting level. Tritium was detected in one of the four control location samples. The dose for consumption of water was less than one mrem per year, historically and for 2010; therefore low-level iodine analysis is not required.

Figure 3.2 shows tritium highest annual mean indicator and control location concentrations with comparisons to 20% of the reporting level. Table 3.2 gives indicator location highest annual means and control means since 1979 for tritium and gross beta. There is no reporting level for gross beta.

Drinking water Location 101 was added to the sampling program in 1999. Figure 3.2 shows an increase beginning in that year. There was an increase in tritium releases in 2006 due to silica removal from the spent fuel pools. This resulted in additional water volume being released from the plant. An extreme drought during the second half of 2007 and much of 2008 affecting the Catawba River Basin resulted in less dilution volume available in Lake Norman.

Figure 3.2 0

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 1979 1982 1985 1988 1991 1994 1997 2000 2003 2006 2009 ConcentrationofTritiuminDrinkingWater IndicatorLocation ControlLocation 20%ReportingLevel pCi/liter

Section 3 - Page 6 Table 3.2 Mean Concentrations of Radionuclides in Drinking Water Gross Beta (pCi/l)

Tritium (pCi/l)

YEAR Indicator Location Control Location Indicator Location Control Location 1979 2.40E0 2.03E0 1.65E2 1.50E2 1980 2.34E0 1.87E0 1.63E2 2.05E2 1981 2.79E0 2.41E0 1.88E2 1.78E2 1982 2.62E0 2.43E0 2.43E2 1.45E2 1983 1.80E0 1.87E0 2.65E2 1.45E2 1984 2.78E0 1.81E0 5.77E2 2.45E2 1985 1.88E0 1.90E0 5.93E2 4.00E2 1986 2.13E0 2.15E0 1.14E3 4.37E2 1987 2.30E0 2.00E0 1.35E3 7.75E2 1988 2.00E0 2.00E0 9.92E2 7.11E2 1989 2.80E0 2.70E0 5.62E2 0.00E0 1990 3.70E0 4.30E0 7.32E2 6.11E2 1991 2.40E0 2.50E0 5.22E2 0.00E0 1992 2.00E0 1.70E0 6.73E2 0.00E0 1993 2.80E0 2.40E0 0.00E0 0.00E0 1994 2.47E0 2.90E0 0.00E0 0.00E0 1995 4.20E0 3.30E0 3.58E2 0.00E0 1996 2.75E0 2.11E0 3.60E2 0.00E0 1997 2.70E0 2.24E0 2.90E2 0.00E0 1998 2.75E0 2.33E0 2.68E2 0.00E0 1999 2.48E0 2.17E0 5.49E2 0.00E0 2000 2.66E0 1.99E0 5.04E2 0.00E0 2001 2.48E0 2.19E0 6.98E2 0.00E0 2002 2.47E0 2.08E0 5.64E2 0.00E0 2003 1.81E0 1.52E0 3.51E2 0.00E0 2004 1.68E0 1.29E0 4.61E2 0.00E0 2005 1.74E0 1.30E0 7.35E2 0.00E0 2006 1.75E0 1.80E0 1.46E3 0.00E0 2007 1.81E0 1.76E0 1.48E3 0.00E0 2008 2.40E0 1.87E0 1.52E3 2.26E2 2009 1.90E0 1.81E0 1.03E3 1.86E2 2010 1.85E0 1.74E0 7.20E2 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 7 3.3 SURFACE WATER In 2010, 39 surface water samples were analyzed for gamma emitting radionuclides, 26 at the two indicator locations and 13 at the control location. Analyses for H-3 were performed on 12 samples, eight at indicator locations and four at the control location.

No detectable gamma activity was found in surface water samples in 2010 and has not been detected since 1988. Tritium was detected in all of the eight indicator composite samples taken in 2010.

Tritium was not detected in any of the four control location composite samples in 2010.

Figure 3.3 shows tritium highest annual mean indicator and control location concentrations. Table 3.3 gives indicator and control location highest annual means since 1979 for tritium.

There was an increase in surface water tritium in 2006 due to silica removal from the spent fuel pools. This resulted in additional water volume being released from the plant. An extreme drought during the second half of 2007 and much of 2008 affecting the Catawba River Basin resulted in less dilution volume available in Lake Norman.

Figure 3.3 There is no reporting level for tritium in surface water 0

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 1979 1982 1985 1988 1991 1994 1997 2000 2003 2006 2009 ConcentrationofTritiuminSurfaceWater IndicatorLocation ControlLocation pCi/liter

Section 3 - Page 8 Table 3.3 Mean Concentrations of Tritium in Surface Water YEAR H-3 Indicator (pCi/l)

H-3 Control (pCi/l) 1979 1.85E2 1.66E2 1980 2.13E2 1.93E2 1981 1.75E2 1.70E2 1982 3.30E2 1.23E2 1983 5.75E2 3.67E2 1984 4.10E2 2.65E2 1985 7.33E2 0.00E0 1986 2.33E3 6.13E2 1987 9.20E2 7.70E2 1988 9.40E2 0.00E0 1989 8.22E2 0.00E0 1990 6.77E2 0.00E0 1991 7.53E2 0.00E0 1992 8.13E2 0.00E0 1993 6.85E2 0.00E0 1994 0.00E0 0.00E0 1995 3.15E2 0.00E0 1996 8.08E2 0.00E0 1997 4.85E2 0.00E0 1998 3.40E2 0.00E0 1999 5.60E2 0.00E0 2000 6.22E2 0.00E0 2001 6.98E2 0.00E0 2002 5.65E2 0.00E0 2003 3.91E2 0.00E0 2004 5.04E2 0.00E0 2005 8.74E2 0.00E0 2006 1.65E3 2.19E2 2007 1.68E3 3.42E2 2008 1.67E3 3.13E2 2009 1.18E3 1.41E2 2010 1.09E3 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 9 3.4 MILK In 2010, 26 milk samples were analyzed for low level I-131 and other gamma emitting radionuclides. One control location was sampled. No indicator dairies were identified by the 2010 land use census.

No detectable activity was found in milk samples in 2010 other than naturally-occurring K-40.

Cs-137 has not been detected in milk samples since 1990 and all other radionuclides have not been detected since 1987.

Table 3.4 gives indicator location highest annual means and control means since 1979 for Cs-137. Since no activity was detected in 2010, no reporting levels were approached.

Table 3.4 Mean Concentrations of Cs-137 in Milk YEAR Cs-137 Indicator (pCi/l)

Cs-137 Control (pCi/l) 1979 2.48E1 6.04E0 1980 1.72E1 4.13E0 1981 2.04E1 4.15E0 1982 1.21E1 5.20E0 1983 2.01E1 2.82E0 1984 1.48E1 2.56E0 1985 1.42E1 2.72E0 1986 3.74E0 3.45E0 1987 5.20E0 8.60E0 1988 3.40E0 2.90E0 1989 6.00E0 5.60E0 1990 5.30E0 2.60E0 1991 0.00E0 0.00E0 1992 0.00E0 0.00E0 1993 0.00E0 0.00E0 1994 0.00E0 0.00E0 1995 0.00E0 0.00E0 1996 0.00E0 0.00E0 1997 0.00E0 0.00E0 1998 0.00E0 0.00E0 1999 0.00E0 0.00E0 2000 0.00E0 0.00E0 2001 0.00E0 0.00E0 2002 0.00E0 0.00E0 2003 0.00E0 0.00E0 2004 0.00E0 0.00E0 2005 0.00E0 0.00E0 2006 0.00E0 0.00E0 2007 0.00E0 0.00E0 2008 0.00E0 0.00E0 2009 0.00E0 0.00E0 2010 0.00E0 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 10 3.5 BROADLEAF VEGETATION In 2010, 48 broadleaf vegetation samples were analyzed, 36 at the three indicator locations and twelve at the control location.

The control location was relocated during 2008 (reference 6.14). There were no gamma emitting radionuclides identified in any indicator location or control location broadleaf vegetation samples during 2010.

No airborne Cs-137 has been released from the plant since 1998. Cs-137 attributable to past nuclear weapons testing is known to exist in many environmental media at low and highly variable levels.

Table 3.5 gives indicator and control location highest annual means since 1979 for Cs-137.

Since no activity was detected in 2010, no reporting levels were approached.

Table 3.5 Mean Concentrations of Cs-137 in Broadleaf Vegetation YEAR Cs-137 Indicator (pCi/kg)

Cs-137 Control (pCi/kg) 1979 2.19E1 1.93E1 1980 2.30E1 1.92E1 1981 3.04E1 2.02E1 1982 2.46E1 1.22E1 1983 9.07E0 7.85E0 1984 1.02E1 1.05E1 1985 8.05E0 2.37E-2 1986 4.03E1 1.27E1 1987 2.20E1 1.70E1 1988 3.90E1 3.40E1 1989 9.60E1 0.00E0 1990 4.00E1 0.00E0 1991 3.30E1 0.00E0 1992 4.90E1 0.00E0 1993 1.60E1 0.00E0 1994 0.00E0 0.00E0 1995 0.00E0 0.00E0 1996 0.00E0 0.00E0 1997 0.00E0 0.00E0 1998 0.00E0 2.69E1 1999 0.00E0 0.00E0 2000 0.00E0 0.00E0 2001 0.00E0 0.00E0 2002 0.00E0 0.00E0 2003 0.00E0 0.00E0 2004 0.00E0 0.00E0 2005 0.00E0 0.00E0 2006 2.98E1 0.00E0 2007 1.34E1 0.00E0 2008 0.00E0 0.00E0 2009 0.00E0 0.00E0 2010 0.00E0 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 11 3.6 FOOD PRODUCTS In 2010, 12 food products (crops) samples were analyzed, all at one indicator location. There is no control location for this media.

No detectable activity has been detected in this media since 1987. Table 3.6 shows Cs-137 indicator highest annual means with preoperational data. Since no activity was detected in 2010, no reporting levels were approached.

Table 3.6 Mean Concentrations of Cs-137 in Food Products YEAR Cs-137 Indicator (pCi/kg) 1979 2.19E1 1980 2.30E1 1981 3.04E1 1982 2.46E1 1983 9.07E0 1984 8.45E0 1985 7.99E0 1986 2.15E1 1987 2.90E1 1988 0.00E0 1989 0.00E0 1990 0.00E0 1991 0.00E0 1992 0.00E0 1993 0.00E0 1994 0.00E0 1995 0.00E0 1996 0.00E0 1997 0.00E0 1998 0.00E0 1999 0.00E0 2000 0.00E0 2001 0.00E0 2002 0.00E0 2003 0.00E0 2004 0.00E0 2005 0.00E0 2006 0.00E0 2007 0.00E0 2008 0.00E0 2009 0.00E0 2010 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 12 3.7 FISH In 2010, 12 fish samples were analyzed for gamma emitting radionuclides, six at the indicator location and six at the control location.

Figure 3.7-1 shows Cs-137 highest annual mean indicator and control location concentrations with comparisons to 5% of the reporting level. Figure 3.7-2 shows Co-60 highest annual mean indicator and control location concentrations also with comparisons to 5% of the reporting level.

Table 3.7 gives indicator location highest annual means since 1980 for all radionuclides detected since the analysis change in 1988.

Co-58 activity was not detected in 2010 in any of the indicator or control samples. Cs-137 activity was detected in one of the six indicator samples taken at Location 129 with a mean concentration of 23.3 pCi/kg, which is 1.17% of the reporting level. Cs-137 was detected in one of the six control samples.

All other radionuclides not shown in the table have demonstrated no detectable activity since 1986.

Section 3 - Page 13 Figure 3.7-1 0

20 40 60 80 100 120 140 1980 1983 1986 1989 1992 1995 1998 2001 2004 2007 2010 ConcentrationofCs137inFish IndicatorLocation ControlLocation 5%ofReportingLevel pCi/kg Figure 3.7-2 0

100 200 300 400 500 600 1980 1983 1986 1989 1992 1995 1998 2001 2004 2007 2010 ConcentrationofCo60inFish IndicatorLocation ControlLocation 5%ofReportingLevel pCi/kg

Section 3 - Page 14 Table 3.7 Mean Concentrations of Radionuclides in Fish (pCi/kg)

YEAR Mn-54 Indicator Co-58 Indicator Co-60 Indicator Cs-134 Indicator Cs-137 Indicator 1980

-1.97E1 8.36E0

-2.25E1

-2.70E1

-4.13E0 1981

-2.71E0

-2.98E0

-2.65E0

-1.99E0 1.80E1 1982

-3.83E0 8.16E0

-4.34E-1

-8.22E-1 2.69E1 1983

-2.60E0 2.60E1 1.11E1

-1.32E0 6.03E1 1984 3.61E0 1.45E2 2.82E1 3.11E1 4.38E1 1985 2.53E-1 7.19E0 1.72E1

-1.56E0 1.86E1 1986 1.03E0 3.17E1 2.96E1 1.67E1 3.49E1 1987 0.00E0 2.71E2 1.25E2 2.60E1 5.10E1 1988 1.20E1 7.70E1 0.00E0 2.70E1 3.60E1 1989 9.00E1 4.05E2 2.99E2 1.10E1 3.50E1 1990 0.00E0 5.60E1 4.10E1 0.00E0 3.30E1 1991 6.20E0 1.40E1 6.50E1 5.90E0 2.60E1 1992 0.00E0 0.00E0 0.00E0 0.00E0 2.90E1 1993 0.00E0 8.20E1 1.30E1 0.00E0 1.60E1 1994 0.00E0 0.00E0 0.00E0 0.00E0 3.10E1 1995 0.00E0 0.00E0 0.00E0 0.00E0 2.70E1 1996 0.00E0 0.00E0 0.00E0 0.00E0 2.78E1 1997 0.00E0 0.00E0 0.00E0 0.00E0 1.62E1 1998 0.00E0 0.00E0 0.00E0 0.00E0 3.21E1 1999 0.00E0 3.53E1 0.00E0 0.00E0 2.10E1 2000 0.00E0 4.28E1 0.00E0 0.00E0 2.34E1 2001 0.00E0 1.32E1 0.00E0 0.00E0 3.04E1 2002 0.00E0 0.00E0 0.00E0 0.00E0 2.33E1 2003 0.00E0 0.00E0 0.00E0 0.00E0 3.05E1 2004 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 2005 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 2006 0.00E0 0.00E0 0.00E0 0.00E0 1.08E1 2007 0.00E0 0.00E0 0.00E0 0.00E0 2.11E1 2008 0.00E0 0.00E0 0.00E0 0.00E0 1.24E1 2009 0.00E0 0.00E0 0.00E0 0.00E0 1.76E1 2010 0.00E0 0.00E0 0.00E0 0.00E0 2.33E1 0.00E0 = no detectable measurements All negative values have been replaced with zeros for calculational purposes

Section 3 - Page 15 3.8 SHORELINE SEDIMENT In 2010, six shoreline sediment samples were analyzed, four from two indicator locations and two at the control location.

Figure 3.8-1 shows Cs-137 highest annual mean indicator and control location concentrations since 1979. Figure 3.8-2 shows Co-60 highest annual mean indicator and control location concentrations since 1979.

Cs-137 activity was detected in two of the four indicator samples taken. The shoreline sediment location with the highest annual mean was Location 130 with a mean concentration of 75.8 pCi/kg. Cs-137 was not detected in any control location samples.

Table 3.8 gives indicator location highest annual means since 1979 for all radionuclides detected since the analysis change in 1988. There is no reporting level for shoreline sediment.

Figure 3.8-1 0

50 100 150 200 250 300 350 400 450 500 1979 1982 1985 1988 1991 1994 1997 2000 2003 2006 2009 ConcentrationofCs137inShorelineSediment IndicatorLocation ControlLocation pCi/kg There is no reporting level for Cs-137 in shoreline sediment

Section 3 - Page 16 Figure 3.8-2 0

50 100 150 200 250 300 1979 1982 1985 1988 1991 1994 1997 2000 2003 2006 2009 ConcentrationofCo60inShorelineSediment IndicatorLocation ControlLocation pCi/kg There is no reporting level for Co-60 in shoreline sediment Table 3.8 Mean Concentrations of Radionuclides in Shoreline Sediment (pCi/kg)

YEAR Mn-54 Indicator Co-58 Indicator Co-60 Indicator Cs-134 Indicator Cs-137 Indicator 1979

-1.07E1 2.25E1

-6.50E0 0.00E0 1.20E1 1980 1.06E1

-8.74E0 2.36E1

-3.53E0 1.44E1 1981 2.13E1 1.20E1 8.21E0 3.97E1 3.36E1 1982 5.38E1 1.66E1

-1.69E0 7.67E1 4.40E1 1983 4.40E0 3.43E1 2.12E1 7.65E1 8.02E1 1984 1.19E1 7.11E1 3.04E1 3.34E1 9.13E1 1985 4.77E0 1.46E1 9.20E0 2.02E1 1.61E2 1986 1.37E1 1.02E1 1.16E1 6.35E1 1.53E2 1987 0.00E0 1.06E2 2.10E1 4.20E1 1.65E2 1988 6.50E0 9.20E1 1.20E1 9.10E0 2.66E2 1989 2.90E1 3.80E1 2.90E1 5.30E1 6.50E1 1990 3.80E1 2.70E1 1.68E2 0.00E0 6.10E1 1991 2.80E1 5.30E1 1.31E2 0.00E0 1.03E2 1992 9.40E0 0.00E0 5.10E1 9.20E0 8.60E1 1993 0.00E0 2.20E1 8.60E1 0.00E0 9.30E1 1994 4.10E1 0.00E0 0.00E0 0.00E0 8.00E1 1995 1.70E1 0.00E0 2.30E1 0.00E0 1.38E2 1996 2.90E1 1.78E1 3.50E1 0.00E0 1.47E2 1997 0.00E0 0.00E0 1.11E2 3.10E1 1.36E2 1998 0.00E0 0.00E0 5.21E1 0.00E0 9.97E1 1999 0.00E0 2.47E1 8.49E1 0.00E0 6.51E1 2000 0.00E0 3.04E1 0.00E0 0.00E0 1.08E2

Section 3 - Page 17 Table 3.8 continued YEAR Mn-54 Indicator Co-58 Indicator Co-60 Indicator Cs-134 Indicator Cs-137 Indicator 2001 0.00E0 0.00E0 0.00E0 0.00E0 2.77E1 2002 2.24E1 0.00E0 0.00E0 0.00E0 1.59E2 2003 0.00E0 0.00E0 0.00E0 0.00E0 1.11E2 2004 0.00E0 0.00E0 0.00E0 0.00E0 7.17E1 2005 0.00E0 0.00E0 0.00E0 0.00E0 8.08E1 2006 0.00E0 0.00E0 0.00E0 0.00E0 1.59E2 2007 0.00E0 0.00E0 0.00E0 0.00E0 1.14E2 2008 0.00E0 0.00E0 0.00E0 0.00E0 1.77E2 2009 0.00E0 0.00E0 0.00E0 0.00E0 5.08E1 2010 0.00E0 0.00E0 0.00E0 0.00E0 7.58E1

Section 3 - Page 18 3.9 DIRECT GAMMA RADIATION 3.9.1 ENVIRONMENTAL TLD In 2010, 163 TLDs were analyzed, 159 at indicator locations, four at the control location.

TLDs are collected and analyzed quarterly. The highest annual mean exposure for an indicator location was 108 milliroentgen. The annual mean exposure for the control location was 89.2 milliroentgen.

Figure 3.9-1 and Table 3.9-A show TLD inner ring (site boundary), outer ring (4-5 miles),

and control location annual averages in milliroentgen per year. Preoperational data and ten year rolling averages are also given. As shown in the graph, inner and outer ring averages historically compare closely, with control data somewhat higher. Inner and outer ring averages comprise a number of data points with the control average representing only one location.

The control location has historically been higher than indicator locations. This is most likely an artifact of the underlying geologic structures at the control location. TLDs located greater than 5 miles from the plant demonstrate a wide range of background radiation levels. The control location is 15.5 miles WNW, well beyond the influence of the plant.

The calculated total body dose from gaseous effluents for 2010 was 2.96E-1 millirem, which is 0.45% of the average inner ring TLD values. Therefore, it can be concluded that discharges from the plant had very little impact on the measured TLD values.

A TLD intercomparison program is conducted as part of the quality assurance program. Results of this program are included in section 5.10.

Figures 3.9-2 and 3.9-3 show the TLD mean for each inner and outer ring TLD location from 1987 through 2010.

3.9.2 ISFSI The McGuire ISFSI is located inside the protected area on the west side of the plant approximately 244 meters from plant centerline. The ISFSI protected area fence on the north side is approximately 60 meters from the owner control fence atop the berm adjacent to Lake Norman and just west of the intake structure. At a distance of 425 meters the ISFSI is closest to the Exclusion Area Boundary (EAB) on the west side along the Catawba River. The nearest resident to the ISFSI is just over a kilometer away in the east sector with the next closest resident at 1.1 kilometers in the WNW sector.

Section 3 - Page 19 The ISFSI is situated in a slight depression in relationship to other structures inside the protected area. The ISFSI direct radiation to the north is shielded by the berm on the south boundary of Lake Norman. The EAB to the west of ISFSI is shielded from direct radiation by the drop in elevation from 754' at the ISFSI to the river bank below the Cowan's Ford Dam. These features lessen the dose impact to the public accessing the EAB west of ISFSI and the Lake Norman shoreline inside the EAB north of ISFSI.

There are 38 loaded casks currently in the ISFSI. There are no effluent releases from the fuel canisters stored inside the shielded casks to the environment. Doses measured by environmental TLDs show little or no change since the current TLD system was implemented.

Figure 3.9-1 0

50 100 150 200 250 1979 1982 1985 1988 1991 1994 1997 2000 2003 2006 2009 DirectGammaRadiation(TLD)Results InnerRing OuterRing Control mR/year There is no reporting level for Direct Radiation (TLD)

Section 3 - Page 20 Table 3.9-A Direct Gamma Radiation (TLD) Results YEAR Inner Ring Average (mR/yr)

Outer Ring Average (mR/yr)

Control (mR/yr) 1979 7.91E1 8.82E1 8.32E1 1980 7.54E1*

8.29E1*

1.05E2 1981 1.01E2 9.31E1 1.05E2 1982 8.95E1 8.97E1 1.10E2 1983 1.16E2 1.14E2 1.30E2 1984 7.85E1 7.83E1 9.02E1 1985 9.54E1 9.69E1 1.27E2 1986 8.91E1 9.35E1 1.10E2 1987 7.58E1 7.71E1 1.23E2 1988 6.03E1 6.42E1 5.48E1 1989 5.37E1 5.30E1 7.55E1 1990 4.34E1 4.78E1 6.25E1 1991 5.14E1 5.59E1 6.80E1 1992 5.65E1 5.55E1 7.60E1 1993 5.61E1 5.71E1 7.20E1 1994 6.40E1 6.93E1 9.55E1 1995 8.36E1 8.25E1 1.08E2 1996 7.18E1 7.02E1 9.88E1 1997 6.22E1 6.68E1 9.45E1 1998 6.59E1 6.32E1 8.69E1 1999 6.23E1 6.05E1 8.96E1 2000 6.50E1 6.08E1 8.97E1 2001 6.51E1 6.22E1 9.33E1 2002 6.57E1 6.43E1 9.48E1 2003 6.74E1 6.45E1 9.20E1 2004 6.46E1 6.33E1 9.16E1 2005 6.62E1 6.34E1 9.44E1 2006 6.75E1 6.58E1 9.17E1 2007 6.84E1 6.60E1 9.00E1 2008 6.69E1 6.58E1 9.14E1 2009 6.67E1 6.53E1 9.12E1 Average (2000 - 2009) 6.64E1 6.41E1 9.20E1 2010 6.63E1 6.53E1 8.92E1

  • Values are based on two quarters due to change in TLD locations.

Section 3 - Page 21 Figure 3.9-2 20 30 40 50 60 70 80 90 100 110 120 N



NNE (144)

NE (145)

ENE (146)

E (147)

ESE (148)

SE (149)

SSE (189)

S (151)

SSW (152)

SW (153)

WSW (190)

W (154)

WNW (156)

NW (143)

NNW



McGuireInnerRing(TLD)Results 2010Mean 1987 2009High/Low/Mean mR/year Table 3.9-B Direct Gamma Radiation (TLD) Results Inner Ring Sector (Location) 1987 - 2009 Mean 1987 - 2009 Low 1987 - 2009 High 2010 Mean NNE (144) 5.94E+01 3.88E+01 8.02E+01 6.20E+01 NE (145) 5.93E+01 3.75E+01 7.59E+01 6.20E+01 ENE (146) 5.72E+01 3.64E+01 8.13E+01 5.80E+01 E (147) 6.08E+01 3.89E+01 8.69E+01 6.20E+01 ESE (148) 5.34E+01 3.75E+01 7.50E+01 5.70E+01 SE (149) 5.06E+01 3.11E+01 6.70E+01 5.20E+01 SSE (189) 6.17E+01 4.73E+01 7.20E+01 6.40E+01 S (151) 6.15E+01 3.97E+01 8.45E+01 6.00E+01 SSW (152) 5.77E+01 3.80E+01 7.64E+01 6.20E+01 SW (153) 7.73E+01 4.89E+01 9.89E+01 8.00E+01 WSW (190) 8.45E+01 6.38E+01 9.41E+01 8.30E+01 W (154) 8.16E+01 4.88E+01 9.93E+01 8.70E+01 WNW (156) 7.59E+01 6.31E+01 1.02E+02 7.30E+01 NW (143) 6.31E+01 3.87E+01 8.15E+01 6.60E+01 NNE (144) 5.94E+01 3.88E+01 8.02E+01 6.20E+01 NE (145) 5.93E+01 3.75E+01 7.59E+01 6.20E+01

Section 3 - Page 22 Figure 3.9-3 20 30 40 50 60 70 80 90 100 110 120 N

(157)

NNE (158)

NE (159)

ENE (160)

E (161)

ESE (162)

SE (163)

SSE (164)

S (165)

SSW (166)

SW (167)

WSW (168)

W (169)

WNW (170)

NW (171)

NNW (172)

McGuireOuterRing(TLD)Results 2010Mean 1987 2009High/Low/Mean mR/year Table 3.9-C Direct Gamma Radiation (TLD) Results Outer Ring Sector (Location) 1987 - 2009 Mean 1987 - 2009 Low 1987 - 2009 High 2010 Mean N (157) 6.38E+01 4.27E+01 8.56E+01 6.60E+01 NNE (158) 6.14E+01 4.37E+01 8.24E+01 6.20E+01 NE (159) 6.54E+01 5.23E+01 8.57E+01 8.90E+01 ENE (160) 6.70E+01 4.82E+01 8.29E+01 7.00E+01 E (161) 6.15E+01 4.07E+01 7.68E+01 6.40E+01 ESE (162) 4.89E+01 3.50E+01 6.70E+01 4.60E+01 SE (163) 6.25E+01 4.43E+01 9.64E+01 4.40E+01 SSE (164) 4.69E+01 3.26E+01 6.37E+01 4.60E+01 S (165) 7.15E+01 4.05E+01 9.00E+01 7.80E+01 SSW (166) 5.56E+01 3.43E+01 7.38E+01 6.90E+01 SW (167) 7.56E+01 6.20E+01 8.94E+01 7.70E+01 WSW (168) 6.17E+01 4.17E+01 7.61E+01 6.40E+01 W (169) 5.96E+01 4.04E+01 7.81E+01 5.80E+01 WNW (170) 8.31E+01 6.18E+01 1.03E+02 8.40E+01 NW (171) 6.73E+01 4.98E+01 9.57E+01 6.50E+01 NNW (172) 6.78E+01 4.42E+01 8.46E+01 6.30E+01

Section 3 - Page 23 3.10 LAND USE CENSUS The land use census was conducted May 19, 2010 as required by SLC 16.11.14. Table 3.10 summarizes census results. A map indicating identified locations is shown in Figure 3.10.

During the 2010 census, no new residences (nearer to the plant), irrigated gardens (superior to existing gardens) or milk locations were identified. The nearest residence is located in the East sector at 0.48 miles. No environmental program changes were required as a result of the 2010 land use census.

Table 3.10 McGuire 2010 Land Use Census Results Sector Distance (Miles)

Sector Distance (Miles)

N Nearest Residence Nearest Garden (irrigated)

Nearest Milk Animal 2.53 2.79 S

Nearest Residence Nearest Garden Nearest Milk Animal 1.45 3.19 NNE Nearest Residence Nearest Garden (irrigated)

Nearest Milk Animal 1.23 2.53 SSW Nearest Residence Nearest Garden Nearest Milk Animal 2.56 2.94 NE Nearest Residence Nearest Garden Nearest Milk Animal 1.21 1.80 SW Nearest Residence Nearest Garden Nearest Milk Animal 1.85 1.98 ENE Nearest Residence Nearest Garden Nearest Milk Animal 0.57 2.54 WSW Nearest Residence Nearest Garden Nearest Milk Animal 1.01 1.33 E

Nearest Residence Nearest Garden Nearest Milk Animal 0.48 2.10 W

Nearest Residence Nearest Garden Nearest Milk Animal 1.15 1.23 ESE Nearest Residence Nearest Garden Nearest Milk Animal 0.65 1.23 WNW Nearest Residence Nearest Garden Nearest Milk Animal 0.88 2.15 SE Nearest Residence Nearest Garden Nearest Milk Animal 0.67 1.18 NW Nearest Residence Nearest Garden Nearest Milk Animal 0.95 1.68 SSE Nearest Residence Nearest Garden Nearest Milk Animal 1.06 2.18 NNW Nearest Residence Nearest Garden (irrigated)

Nearest Milk Animal 1.48 1.69

- indicates no occurrences within the 5 mile radius

Section 3 - Page 24 Figure 3.10 McGuire Nuclear Station 2010 Land Use Census Map legend Residence Garden

/'V Public Roads A/ Railroad

,.........' Counly Boundary Water Approximate location oIlealures shown N W o 0.5 1

2 Miles PrQjec::lion NCSP NA027 May 2010

Section 4 - Page 1 4.0 EVALUATION OF DOSE 4.1 DOSE FROM ENVIRONMENTAL MEASUREMENTS Annual doses to maximum exposed individuals were estimated based on measured concentrations of radionuclides in 2010 MNS REMP samples. The primary purpose of estimating doses based on sample results is to allow comparison to effluent program dose estimates.

Doses based on sample results were calculated using the methodology and data presented in NRC Regulatory Guide 1.109. Measured radionuclide concentrations, averaged over the entire year for a specific radionuclide, indicator location and sample type, were used to calculate REMP-based doses. Where applicable, average background concentration at the corresponding control location was subtracted.

Regulatory Guide 1.109 consumption rates for the maximum exposed individual were used in the calculations. When the guide listed NO DATA as the dose factor for a given radionuclide and organ, a dose factor of zero was assumed.

Maximum dose estimates (Highest Annual Mean Concentration) based on drinking water, fish, and shoreline sediment sample results are reported in Table 4.1-A. The individual critical population and pathway dose calculations are reported in Table 4.1-B.

REMP-based dose estimates are not reported for airborne radioiodine, milk or vegetation sample types because no radionuclides other than naturally occurring K-40 and Be-7 were detected in the samples. Dose estimates are not reported for surface water because sampled surface water is not considered to be a potable drinking water source although surface water tritium concentrations are used in calculating doses from fish. Exposure estimates based upon REMP TLD results are discussed in Section 3.9.

The maximum environmental organ dose estimate for any single sample type (excluding TLD results) collected during 2010 was 7.45E-2 mrem to the maximum exposed child liver, total body, thyroid, kidney, lung, and GI-LLI from the consumption of drinking water.

4.2 ESTIMATED DOSE FROM RELEASES Throughout the year, dose estimates were calculated based on actual 2010 liquid and gaseous effluent release data. Effluent-based dose estimates were calculated using the RETDAS computer program which employs methodology and data presented in NRC Regulatory Guide 1.109. These doses are shown in Table 4.1-A along with the corresponding REMP-based dose estimates. Summaries of RETDAS dose calculations are reported in the Annual Radioactive Effluent Release Report (reference 6.6).

The effluent-based liquid release doses are summations of the dose contributions from the drinking water, fish, and shoreline pathways. For iodine, particulate, and tritium

Section 4 - Page 2 exposure the effluent-based gaseous release doses are summations of the dose contributors from ground/plane, inhalation, milk and vegetation pathways.

4.3 COMPARISON OF DOSES The environmental and effluent dose estimates given in Table 4.1-A agree reasonably well. The similarity of the doses indicate that the radioactivity levels in the environment do not differ significantly from those expected based on effluent measurements and modeling of the environmental exposure pathways. This indicates that effluent program dose estimates are both valid and reasonably conservative.

There are some differences in how effluent and environmental doses are calculated that affect the comparison. Doses calculated from environmental data are conservative because they are based on a mean that includes only samples with a net positive activity versus a mean that includes all sample results (i.e. zero results are not included in the mean). Also, airborne tritium is not measured in environmental samples but is used to calculate effluent doses.

In addition, McGuire began reporting estimated dose from effluent Carbon 14 (C-14).

This change came about with the issuing of Regulatory Guide 1.21, Revision 2, Measuring, Evaluating and Reporting Radioactive Material in Liquid and Gaseous Effluents and Solid Waste. A description of this change is found in the 2010 Annual Radiological Effluent Release Report. C-14 is not measured in the environment and therefore, environmental and effluent doses from C-14 cannot be compared directly.

In calculations based on liquid release pathways, drinking water and fish consumption were the predominant dose pathways based on environmental and effluent data. The maximum total organ dose based on 2010 environmental sample results was 9.77E-2 mrem to the child liver. The maximum total organ dose of 1.57E-1 mrem for liquid effluent-based estimates was to the child liver.

In calculations based on gaseous release pathways, vegetation was the predominant dose pathway for effluent samples. The maximum organ dose for gaseous effluent estimates was 9.18E-1 mrem to the child bone. No radioactivity was detected from gaseous pathways in environmental samples; therefore, there is no calculated dose.

The doses calculated do not exceed 40CFR190 or 10CFR50 dose commitment limits for members of the public. Doses to members of the public attributable to the operation of MNS are being maintained well within regulatory limits.

TABLE 4.1-A Page 1 of 2 MCGUIRE NUCLEAR STATION 2010 ENVIRONMENTAL AND EFFLUENT DOSE COMPARISON LIQUID RELEASE PATHWAY Organ Environmental or Effluent Data Critical Age (1)

Critical Pathway (2)

Location Maximum Dose (3)

(mrem)

Skin Environmental Teen Shoreline Sediment 130 (0.52 mi SW) 1.99E-04 Skin Effluent Teen Shoreline Sediment Discharge Pt.

8.05E-04 Bone Environmental Child Fish 129 (0.51 mi ENE) 2.28E-02 Bone Effluent Child Fish Discharge Pt.

1.83E-02 Liver Environmental Child Drinking Water 101 (3.31 mi E) 9.77E-02 Liver Effluent Child Drinking Water 3.31 mi E 1.57E-01 T. Body Environmental Child Drinking Water 101 (3.31 mi E) 7.91E-02 T. Body Effluent Child Drinking Water 3.31 mi E 1.41E-01 Thyroid Environmental Child Drinking Water 101 (3.31 mi E) 7.59E-02 Thyroid Effluent Child Drinking Water 3.31 mi E 1.38E-01 Kidney Environmental Child Drinking Water 101 (3.31 mi E) 8.30E-02 Kidney Effluent Child Drinking Water 3.31 mi E 1.44E-01 Lung Environmental Child Drinking Water 101 (3.31 mi E) 7.84E-02 Lung Effluent Child Drinking Water 3.31 mi E 1.40E-01 GI-LLI Environmental Child Drinking Water 101 (3.31 mi E) 7.60E-02 GI-LLI Effluent Child Drinking Water 3.31 mi E 1.40E-01 (1) Critical Age is the highest total dose (all pathways) to an age group.

(2) Critial Pathway is the highest individual dose within the identified Critical Age group.

(3) Maximum dose is a summation of the fish, drinking water and shoreline sediment pathways.

Section 4 - Page 3

Page 2 of 2 GASEOUS RELEASE PATHWAY IODINE, PARTICULATE, and TRITIUM Organ Environmental or Effluent Data Critical Age (1)

Critical Pathway (2)

Location Maximum Dose (3)

(mrem)

Skin Environmental 0.00E+00 Skin Effluent All Ground Plane 1.5 mi. NE 2.45E-05 Bone Environmental 0.00E+00 Bone Effluent Child Vegetation 1.5 mi. NE 9.18E-01 Liver Environmental 0.00E+00 Liver Effluent Teen Vegetation 1.5 mi. NE 2.96E-01 T. Body Environmental 0.00E+00 T. Body Effluent Child Vegetation 1.5 mi. NE 2.96E-01 Thyroid Environmental 0.00E+00 Thyroid Effluent Child Vegetation 1.5 mi. NE 2.96E-01 Kidney Environmental 0.00E+00 Kidney Effluent Child Vegetation 1.5 mi. NE 2.96E-01 Lung Environmental 0.00E+00 Lung Effluent Child Vegetation 1.5 mi. NE 2.96E-01 GI-LLI Environmental 0.00E+00 GI-LLI Effluent Child Vegetation 1.5 mi. NE 2.96E-01 (1) Critical Age is the highest total dose (all pathways) to an age group.

(2) Critial Pathway is the highest individual dose within the identified Critical Age group.

(3) Maximum dose is a summation of the ground/plane, inhalation, milk and vegetation pathways.

Section 4 - Page 4

TABLE 4.1-B Maximum Individual Dose for 2010 based on Environmental Measurements (mrem) for McGuire Nuclear Station Age Sample Medium Bone Liver T. Body Thyroid Kidney Lung GI-LLI Skin Infant Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 0.00E+00 Child Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 7.45E-02 7.45E-02 7.45E-02 7.45E-02 7.45E-02 7.45E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Broadleaf Vegetation 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fish 2.28E-02 2.32E-02 4.59E-03 1.37E-03 8.48E-03 3.93E-03 1.51E-03 0.00E+00 Shoreline Sediment 0.00E+00 0.00E+00 3.57E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.16E-05 TOTAL 2.28E-02 9.77E-02 7.91E-02 7.59E-02 8.30E-02 7.84E-02 7.60E-02 4.16E-05 Teen Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 3.89E-02 3.89E-02 3.89E-02 3.89E-02 3.89E-02 3.89E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Broadleaf Vegetation 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fish 1.81E-02 2.57E-02 1.01E-02 1.66E-03 9.86E-03 4.85E-03 2.01E-03 0.00E+00 Shoreline Sediment 0.00E+00 0.00E+00 1.71E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.99E-04 TOTAL 1.81E-02 6.46E-02 4.92E-02 4.06E-02 4.88E-02 4.38E-02 4.09E-02 1.99E-04 Adult Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 5.52E-02 5.52E-02 5.52E-02 5.52E-02 5.52E-02 5.52E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Broadleaf Vegetation 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fish 1.69E-02 2.53E-02 1.73E-02 2.16E-03 1.00E-02 4.77E-03 2.61E-03 0.00E+00 Shoreline Sediment 0.00E+00 0.00E+00 3.06E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.57E-05 TOTAL 1.69E-02 8.05E-02 7.25E-02 5.74E-02 6.52E-02 6.00E-02 5.78E-02 3.57E-05 Note: Dose tables are provided for sample media displaying positive nuclide occurrence.

Section 4 - Page 5

McGuire Nuclear Station Dose from Drinking Water Pathway for 2010 Data Maximum Exposed Infant Infant Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

330 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 1.99E-05 4.51E-06 NO DATA 4.41E-06 NO DATA 7.31E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 3.60E-06 8.98E-06 NO DATA NO DATA NO DATA 8.97E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 3.08E-05 5.38E-05 2.12E-05 NO DATA NO DATA 1.59E-05 2.57E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 1.08E-05 2.55E-05 NO DATA NO DATA NO DATA 2.57E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 1.84E-05 6.31E-05 2.91E-05 NO DATA 3.06E-05 NO DATA 5.33E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 4.20E-08 1.73E-08 1.00E-08 NO DATA 1.24E-08 NO DATA 1.46E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 2.06E-07 5.02E-08 3.56E-08 NO DATA 5.41E-08 NO DATA 2.50E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 3.59E-05 4.23E-05 1.86E-05 1.39E-02 4.94E-05 NO DATA 1.51E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 3.77E-04 7.03E-04 7.10E-05 NO DATA 1.81E-04 7.42E-05 1.91E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 5.22E-04 6.11E-04 4.33E-05 NO DATA 1.64E-04 6.64E-05 1.91E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 1.71E-04 1.71E-07 8.81E-06 NO DATA 4.06E-08 1.05E-07 4.20E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 101 720 0.00E+00 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 Dose Commitment (mrem) =

0.00E+00 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 7.32E-02 Section 4 - Page 6

McGuire Nuclear Station Dose from Drinking Water Pathway for 2010 Data Maximum Exposed Child Child Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

510 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 1.07E-05 2.85E-06 NO DATA 3.00E-06 NO DATA 8.98E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 1.80E-06 5.51E-06 NO DATA NO DATA NO DATA 1.05E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 1.65E-05 2.67E-05 1.33E-05 NO DATA NO DATA 7.74E-06 2.78E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C0-60 NO DATA 5.29E-06 1.56E-05 NO DATA NO DATA NO DATA 2.93E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 1.37E-05 3.65E-05 2.27E-05 NO DATA 2.30E-05 NO DATA 6.41E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 2.25E-08 8.76E-09 6.26E-09 NO DATA 8.23E-09 NO DATA 1.62E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 1.16E-07 2.55E-08 2.27E-08 NO DATA 3.65E-08 NO DATA 2.66E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 1.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 NO DATA 1.54E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 2.34E-04 3.84E-04 8.10E-05 NO DATA 1.19E-04 4.27E-05 2.07E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 3.27E-04 3.13E-04 4.62E-05 NO DATA 1.02E-04 3.67E-05 1.96E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 8.31E-05 7.28E-08 4.85E-06 NO DATA 2.37E-08 4.34E-08 4.21E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 101 720 0.00E+00 7.45E-02 7.45E-02 7.45E-02 7.45E-02 7.45E-02 7.45E-02 Dose Commitment (mrem) =

0.00E+00 7.45E-02 7.45E-02 7.45E-02 7.45E-02 7.45E-02 7.45E-02 Section 4 - Page 7

McGuire Nuclear Station Dose from Fish Pathway for 2010 Data Maximum Exposed Child Child Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

H-3 Concentration in Fish = Surface Water pCi/l x Bioaccumulation Factor 0.9 pCi/kg per pCi/l = 1090 pCi/l x 0.9 = 981 pCi/kg Usage (intake in one year) =

6.9 kg Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Fish Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 1.07E-05 2.85E-06 NO DATA 3.00E-06 NO DATA 8.98E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 1.80E-06 5.51E-06 NO DATA NO DATA NO DATA 1.05E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 1.65E-05 2.67E-05 1.33E-05 NO DATA NO DATA 7.74E-06 2.78E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C0-60 NO DATA 5.29E-06 1.56E-05 NO DATA NO DATA NO DATA 2.93E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 1.37E-05 3.65E-05 2.27E-05 NO DATA 2.30E-05 NO DATA 6.41E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 2.34E-04 3.84E-04 8.10E-05 NO DATA 1.19E-04 4.27E-05 2.07E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 3.27E-04 3.13E-04 4.62E-05 NO DATA 1.02E-04 3.67E-05 1.96E-06 129 10.1 2.28E-02 2.18E-02 3.22E-03 0.00E+00 7.11E-03 2.56E-03 1.37E-04 H-3 NO DATA 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 128 981 0.00E+00 1.37E-03 1.37E-03 1.37E-03 1.37E-03 1.37E-03 1.37E-03 Dose Commitment (mrem) =

2.28E-02 2.32E-02 4.59E-03 1.37E-03 8.48E-03 3.93E-03 1.51E-03 Section 4 - Page 8

McGuire Nuclear Station Dose from Shoreline Sediment Pathway for 2010 Data Maximum Exposed Child Shoreline Recreation =

14 hr (in one year)

Shore Width Factor =

0.3 (lake shore - location 129)

Shore Width Factor =

0.2 (river shoreline - location 130)

Sediment Surface Mass =

40 kg/m2 Child Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCi/m2) x Shore Width Factor x Sediment Surface Mass (kg/m2) x Sediment Concentration (pCi/kg)

External Dose Factor Standing Highest Annual Net Dose on Contaminated Ground Mean Concentration (mrem/hr per pCi/m2)

Indicator Sediment (mrem)

Radionuclide T. Body Skin Location (pCi/kg)

T. Body Skin Mn-54 5.80E-09 6.80E-09 ALL 0.00 0.00E+00 0.00E+00 Co-58 7.00E-09 8.20E-09 ALL 0.00 0.00E+00 0.00E+00 Co-60 1.70E-08 2.00E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-134 1.20E-08 1.40E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-137 4.20E-09 4.90E-09 130 75.8 3.57E-05 4.16E-05 Dose Commitment (mrem) =

3.57E-05 4.16E-05 Section 4 - Page 9

McGuire Nuclear Station Dose from Drinking Water Pathway for 2010 Data Maximum Exposed Teen Teen Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

510 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 5.90E-06 1.17E-06 NO DATA 1.76E-06 NO DATA 1.21E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 9.72E-07 2.24E-06 NO DATA NO DATA NO DATA 1.34E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 5.87E-06 1.37E-05 5.29E-06 NO DATA NO DATA 4.32E-06 3.24E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.81E-06 6.33E-06 NO DATA NO DATA NO DATA 3.66E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 5.76E-06 2.00E-05 9.33E-06 NO DATA 1.28E-05 NO DATA 8.47E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 8.22E-09 4.56E-09 2.51E-09 NO DATA 4.42E-09 NO DATA 1.95E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 4.12E-08 1.30E-08 8.94E-09 NO DATA 1.91E-08 NO DATA 3.00E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 5.85E-06 8.19E-06 4.40E-06 2.39E-03 1.41E-05 NO DATA 1.62E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 8.37E-05 1.97E-04 9.14E-05 NO DATA 6.26E-05 2.39E-05 2.45E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 1.12E-04 1.49E-04 5.19E-05 NO DATA 5.07E-05 1.97E-05 2.12E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 2.84E-05 3.48E-08 1.83E-06 NO DATA 1.18E-08 2.34E-08 4.38E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 101 720 0.00E+00 3.89E-02 3.89E-02 3.89E-02 3.89E-02 3.89E-02 3.89E-02 Dose Commitment (mrem)=

0.00E+00 3.89E-02 3.89E-02 3.89E-02 3.89E-02 3.89E-02 3.89E-02 Section 4 - Page 10

McGuire Nuclear Station Dose from Fish Pathway for 2010 Data Maximum Exposed Teen Teen Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

H-3 Concentration in Fish = Surface Water pCi/l x Bioaccumulation Factor 0.9 pCi/kg per pCi/l = 1090 pCi/l x 0.9 = 981 pCi/kg Usage (intake in one year) =

16 kg Highest Annual Ingestion Dose Factor Net Mean Dose (mrem)

Concentration Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 5.90E-06 1.17E-06 NO DATA 1.76E-06 NO DATA 1.21E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 9.72E-07 2.24E-06 NO DATA NO DATA NO DATA 1.34E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 5.87E-06 1.37E-05 5.29E-06 NO DATA NO DATA 4.32E-06 3.24E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.81E-06 6.33E-06 NO DATA NO DATA NO DATA 3.66E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 5.76E-06 2.00E-05 9.33E-06 NO DATA 1.28E-05 NO DATA 8.47E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 8.37E-05 1.97E-04 9.14E-05 NO DATA 6.26E-05 2.39E-05 2.45E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 1.12E-04 1.49E-04 5.19E-05 NO DATA 5.07E-05 1.97E-05 2.12E-06 129 10.1 1.81E-02 2.41E-02 8.39E-03 0.00E+00 8.19E-03 3.18E-03 3.43E-04 H-3 NO DATA 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 128 981 0.00E+00 1.66E-03 1.66E-03 1.66E-03 1.66E-03 1.66E-03 1.66E-03 Dose Commitment (mrem) =

1.81E-02 2.57E-02 1.01E-02 1.66E-03 9.86E-03 4.85E-03 2.01E-03 Section 4 - Page 11

McGuire Nuclear Station Dose from Shoreline Sediment Pathway for 2010 Data Maximum Exposed Teen Shoreline Recreation =

67 hr (in one year)

Shore Width Factor =

0.3 (lake shore - location 129)

Shore Width Factor =

0.2 (river shoreline - location 130)

Sediment Surface Mass =

40 kg/m2 Teen Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCi/m2) x Shore Width Factor x Sediment Surface Mass (kg/m2) x Sediment Concentration (pCi/kg)

External Dose Factor Standing Highest Annual Net Dose on Contaminated Ground Mean Concentration (mrem/hr per pCi/m2)

Indicator Sediment (mrem)

Radionuclide T. Body Skin Location (pCi/kg)

T. Body Skin Mn-54 5.80E-09 6.80E-09 ALL 0.00 0.00E+00 0.00E+00 Co-58 7.00E-09 8.20E-09 ALL 0.00 0.00E+00 0.00E+00 Co-60 1.70E-08 2.00E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-134 1.20E-08 1.40E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-137 4.20E-09 4.90E-09 130 75.8 1.71E-04 1.99E-04 Dose Commitment (mrem) =

1.71E-04 1.99E-04 Section 4 - Page 12

McGuire Nuclear Station Dose from Drinking Water Pathway for 2010 Data Maximum Exposed Adult Adult Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

730 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 4.57E-06 8.72E-07 NO DATA 1.36E-06 NO DATA 1.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 7.45E-07 1.67E-06 NO DATA NO DATA NO DATA 1.51E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 4.34E-06 1.02E-05 3.91E-06 NO DATA NO DATA 2.85E-06 3.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.14E-06 4.72E-06 NO DATA NO DATA NO DATA 4.02E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 4.84E-06 1.54E-05 6.96E-06 NO DATA 1.03E-05 NO DATA 9.70E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 6.22E-09 3.46E-09 1.86E-09 NO DATA 3.42E-09 NO DATA 2.10E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 3.04E-08 9.75E-09 6.60E-09 NO DATA 1.53E-08 NO DATA 3.09E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 NO DATA 1.57E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 6.22E-05 1.48E-04 1.21E-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 7.97E-05 1.09E-04 7.14E-05 NO DATA 3.70E-05 1.23E-05 2.11E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 2.03E-05 2.55E-08 1.33E-06 NO DATA 8.67E-09 1.46E-08 4.18E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 101 720 0.00E+00 5.52E-02 5.52E-02 5.52E-02 5.52E-02 5.52E-02 5.52E-02 Dose Commitment (mrem) =

0.00E+00 5.52E-02 5.52E-02 5.52E-02 5.52E-02 5.52E-02 5.52E-02 Section 4 - Page 13

McGuire Nuclear Station Dose from Fish Pathway for 2010 Data Maximum Exposed Adult Adult Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

H-3 Concentration in Fish = Surface Water pCi/l x Bioaccumulation Factor 0.9 pCi/kg per pCi/l = 1090 pCi/l x 0.9 = 981 pCi/kg Usage (intake in one year) =

21 kg Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 4.57E-06 8.72E-07 NO DATA 1.36E-06 NO DATA 1.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 7.45E-07 1.67E-06 NO DATA NO DATA NO DATA 1.51E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 4.34E-06 1.02E-05 3.91E-06 NO DATA NO DATA 2.85E-06 3.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.14E-06 4.72E-06 NO DATA NO DATA NO DATA 4.02E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 4.84E-06 1.54E-05 6.96E-06 NO DATA 1.03E-05 NO DATA 9.70E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 6.22E-05 1.48E-04 1.21E-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 7.97E-05 1.09E-04 7.14E-05 NO DATA 3.70E-05 1.23E-05 2.11E-06 129 10.1 1.69E-02 2.31E-02 1.51E-02 0.00E+00 7.85E-03 2.61E-03 4.48E-04 H-3 NO DATA 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 128 981 0.00E+00 2.16E-03 2.16E-03 2.16E-03 2.16E-03 2.16E-03 2.16E-03 Dose Commitment (mrem) =

1.69E-02 2.53E-02 1.73E-02 2.16E-03 1.00E-02 4.77E-03 2.61E-03 Section 4 - Page 14

McGuire Nuclear Station Dose from Shoreline Sediment Pathway for 2010 Data Maximum Exposed Adult Shoreline Recreation =

12 hr (in one year)

Shore Width Factor =

0.3 (lake shore - location 129)

Shore Width Factor =

0.2 (river shoreline - location 130)

Sediment Surface Mass =

40 kg/m2 Adult Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCi/m2) x Shore Width Factor x Sediment Surface Mass (kg/m2) x Sediment Concentration (pCi/kg)

External Dose Factor Standing Highest Annual Net Dose on Contaminated Ground Mean Concentration (mrem)

(mrem/hr per pCi/m2)

Indicator Sediment Radionuclide T. Body Skin Location (pCi/kg)

T. Body Skin Mn-54 5.80E-09 6.80E-09 ALL 0.00 0.00E+00 0.00E+00 Co-58 7.00E-09 8.20E-09 ALL 0.00 0.00E+00 0.00E+00 Co-60 1.70E-08 2.00E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-134 1.20E-08 1.40E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-137 4.20E-09 4.90E-09 130 75.8 3.06E-05 3.57E-05 Dose Commitment (mrem) =

3.06E-05 3.57E-05 Section 4 - Page 15

Section 5 - Page 1 5.0 QUALITY ASSURANCE 5.1 SAMPLE COLLECTION EnRad Laboratories, Fisheries, and Aquatic Ecology performed the environmental sample collections as specified by approved sample collection procedures.

5.2 SAMPLE ANALYSIS EnRad Laboratories performed the environmental sample analyses as specified by approved analysis procedures. EnRad Laboratories is located in Huntersville, North

Carolina, at Duke Energy Corporation's Environmental Center.

5.3 DOSIMETRY ANALYSIS The Radiation Dosimetry and Records group performed environmental dosimetry measurements as specified by approved dosimetry analysis procedures.

5.4 LABORATORY EQUIPMENT QUALITY ASSURANCE 5.4.1 DAILY QUALITY CONTROL EnRad Laboratories has an internal quality assurance program which monitors each type of instrumentation for reliability and accuracy. Daily quality control checks ensure that instruments are in proper working order and these checks are used to monitor instrument performance.

5.4.2 CALIBRATION VERIFICATION National Institute of Standards and Technology (NIST) standards that represent counting geometries are analyzed as unknowns at various frequencies ranging from weekly to annually to verify that efficiency calibrations are valid. The frequency is dependent upon instrument use and performance. Investigations are performed and documented should calibration verification data fall out of limits.

Duke Energy Corporations Environmental Center

Section 5 - Page 2 5.4.3 BATCH PROCESSING Method quality control samples are analyzed with sample analyses that are processed in batches. These include gross beta in drinking water and all tritium analyses.

5.5 DUKE ENERGY INTERCOMPARISON PROGRAM EnRad Laboratories participated in the Duke Energy Nuclear Generation Department Intercomparison Program during 2010. Interlaboratory cross-check standards, including, Marinelli beakers, air filters, air cartridges, gross beta on smears, and tritium in water samples were analyzed at various times of the year. A summary of the EnRad Laboratory program results for 2010 is documented in Table 5.0-A.

5.6 ERA PROFICIENCY TESTING EnRad Laboratories performed method proficiency testing through a program administered by Environmental Resource Associates (ERA) of Arvada, CO. ERA supplied requested method proficiency samples for analysis and nuclide concentration determination. ERA reported proficiency test results to the North Carolina Department of Health and Human Services, North Carolina Public Health Drinking Water Laboratory Certification Program. A summary of these proficiency test data for 2010 is documented in Table 5.0-B.

5.7 DUKE ENERGY AUDITS The McGuire Nuclear Station Radiological Environmental Monitoring Program was audited by the Quality Assurance Group in 2010. Procedure and report enhancements were identified by this audit (reference 6.14).

In addition, an item was identified concerning the calibration media used for fish and vegetation. Special tests were performed to confirm that the existing calibration media are acceptable. Additional information is included in Table 5.0-A and reference 6.15.

5.8 U.S. NUCLEAR REGULATORY COMMISSION INSPECTIONS The McGuire Nuclear Station Radiological Environmental Monitoring Program was not audited by the NRC in 2010. The program was audited by the NRC in 2009 (reference 6.12). There were no REMP findings identified by the 2009 audit.

5.9 STATE OF NORTH CAROLINA INTERCOMPARISON PROGRAM EnRad Laboratories routinely participates with the State of North Carolina Department of Environmental Health and Natural Resources (DEHNR) in an intercomparison program. EnRad Laboratories sends air, surface water, milk, crops,

Section 5 - Page 3 vegetation, sediment, and fish samples which have been collected to the State of North Carolina Radiation Protection Section.

5.10 TLD INTERCOMPARISON PROGRAM 5.10.1 NUCLEAR TECHNOLOGY SERVICES INTERCOMPARISON PROGRAM Radiation Dosimetry and Records participates in a quarterly TLD intercomparison program administered by Nuclear Technology Services, Inc.

of Roswell, GA. Nuclear Technology Services irradiates environmental dosimeters quarterly and sends them to the Radiation Dosimetry and Records group for analysis of the unknown estimated delivered exposure. A summary of the Nuclear Technology Services Intercomparison Report is documented in Table 5.0-C.

5.10.2 INTERNAL CROSSCHECK (DUKE ENERGY)

Radiation Dosimetry and Records participates in a quarterly TLD intracomparison program administered internally by the Dosimetry Lab. The Dosimetry Lab Staff irradiates environmental dosimeters quarterly and submits them for analysis of the unknown estimated delivered exposure. A summary of the Internal Cross Check (Duke Energy) Result is documented in Table 5.0-C.

Cross-Check samples are normally analyzed a minimum of three times. A status of "3 Pass" indicates that all three analyses yielded results within the designated acceptance range. A status of "1 Pass" indicates that one analysis of the cross check was performed If applicable, footnote explanations are included following this table.

Gamma in Water 3.5 liters Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 2/22/2010 Q101GWR Co-57 0.86 - 1.52 E4 1.14 E4 1.16 E4 3 Pass Co-60 2.72 - 4.82 E3 3.62 E3 3.66 E3 3 Pass Ba-133 5.31 - 9.43 E3 7.09 E3 5.70 E3 3 Pass Cs-137 4.67 - 8.27 E3 6.22 E3 6.15 E3 3 Pass 6/2/2010 Q102GWSL Cr-51 1.15 - 2.05 E5 1.54 E5 1.85 E5 3 Pass Mn-54 4.91 - 8.70 E4 6.54 E4 6.65 E4 3 Pass Co-58 3.10 - 5.49 E4 4.13 E4 4.37 E4 3 Pass Fe-59 3.79 - 6.72 E4 5.05 E4 5.87 E4 3 Pass Co-60 5.63 - 9.99 E4 7.51 E4 7.39 E4 3 Pass Zn-65 6.00 - 10.63 E4 7.99 E4 8.28 E4 3 Pass Cs-134 3.62 - 6.42 E4 4.82 E4 4.33 E4 3 Pass Cs-137 4.29 - 7.61 E4 5.72 E4 5.38 E4 3 Pass Ce-141 3.66 - 6.49 E4 4.88 E4 5.70 E4 3 Pass 9/9/2010 Q103GWSL Cr-51 1.00 - 1.77 E5 1.33 E5 1.35 E5 3 Pass Mn-54 4.34 - 7.69 E4 5.79 E4 6.05 E4 3 Pass Co-58 2.82 - 5.00 E4 3.76 E4 3.82 E4 3 Pass Fe-59 3.64 - 6.46 E4 4.86 E4 5.21 E4 3 Pass Co-60 6.13 - 10.86 E4 8.17 E4 8.38 E4 3 Pass Zn-65 7.44 - 13.19 E4 9.92 E4 10.43 E4 3 Pass Cs-134 3.35 - 5.94 E4 4.47 E4 4.13 E4 3 Pass Cs-137 3.38 - 6.00 E4 4.51 E4 4.45 E4 3 Pass Ce-141 5.41 - 9.59 E4 7.21 E4 7.37 E4 3 Pass Gamma in Water 1.0 liter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 2/22/2010 Q101GWR Co-57 0.86 - 1.52 E4 1.14 E4 1.12 E4 3 Pass Co-60 2.72 - 4.82 E3 3.62 E3 3.73 E3 3 Pass Ba-133 5.31 - 9.43 E3 7.09 E3 5.56 E3 3 Pass Cs-137 4.67 - 8.27 E3 6.22 E3 6.06 E3 3 Pass ENRAD LABORATORIES TABLE 5.0-A DUKE ENERGY INTERLABORATORY COMPARISON PROGRAM 2010 CROSS-CHECK RESULTS FOR Section 5 - Page 4

Gamma in Water 1.0 liter, continued Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 6/2/2010 Q102GWSL Cr-51 1.15 - 2.05 E5 1.54 E5 1.85 E5 2 Pass Mn-54 4.91 - 8.70 E4 6.54 E4 6.70 E4 2 Pass Co-58 3.10 - 5.49 E4 4.13 E4 4.38 E4 2 Pass Fe-59 3.79 - 6.72 E4 5.05 E4 5.91 E4 2 Pass Co-60 5.63 - 9.99 E4 7.51 E4 7.44 E4 2 Pass Zn-65 6.00 - 10.63 E4 7.99 E4 8.35 E4 2 Pass Cs-134 3.62 - 6.42 E4 4.82 E4 4.25 E4 2 Pass Cs-137 4.29 - 7.61 E4 5.72 E4 5.39 E4 2 Pass Ce-141 3.66 - 6.49 E4 4.88 E4 5.69 E4 2 Pass 9/9/2010 Q103GWSL Cr-51 1.00 - 1.77 E5 1.33 E5 1.33 E5 3 Pass Mn-54 4.34 - 7.69 E4 5.79 E4 5.98 E4 3 Pass Co-58 2.82 - 5.00 E4 3.76 E4 3.76 E4 3 Pass Fe-59 3.64 - 6.46 E4 4.86 E4 5.16 E4 3 Pass Co-60 6.13 - 10.86 E4 8.17 E4 8.32 E4 3 Pass Zn-65 7.44 - 13.19 E4 9.92 E4 10.43 E4 3 Pass Cs-134 3.35 - 5.94 E4 4.47 E4 3.98 E4 3 Pass Cs-137 3.38 - 6.00 E4 4.51 E4 4.43 E4 3 Pass Ce-141 5.41 - 9.59 E4 7.21 E4 7.24 E4 3 Pass Gamma in Water 0.5 liter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 2/22/2010 Q101GWR Co-57 0.86 - 1.52 E4 1.14 E4 1.12 E4 3 Pass Co-60 2.72 - 4.82 E3 3.62 E3 3.73 E3 3 Pass Ba-133 5.31 - 9.43 E3 7.09 E3 5.53 E3 3 Pass Cs-137 4.67 - 8.27 E3 6.22 E3 6.04 E3 3 Pass 6/2/2010 Q102GWSL Cr-51 1.15 - 2.05 E5 1.54 E5 1.81 E5 3 Pass Mn-54 4.91 - 8.70 E4 6.54 E4 6.45 E4 3 Pass Co-58 3.10 - 5.49 E4 4.13 E4 4.22 E4 3 Pass Fe-59 3.79 - 6.72 E4 5.05 E4 5.73 E4 3 Pass Co-60 5.63 - 9.99 E4 7.51 E4 7.24 E4 3 Pass Zn-65 6.00 - 10.63 E4 7.99 E4 8.10 E4 3 Pass Cs-134 3.62 - 6.42 E4 4.82 E4 4.10 E4 3 Pass Cs-137 4.29 - 7.61 E4 5.72 E4 5.17 E4 3 Pass Ce-141 3.66 - 6.49 E4 4.88 E4 5.46 E4 3 Pass 9/9/2010 Q103GWSL Cr-51 1.00 - 1.77 E5 1.33 E5 1.26 E5 3 Pass Mn-54 4.34 - 7.69 E4 5.79 E4 5.55 E4 3 Pass Co-58 2.82 - 5.00 E4 3.76 E4 3.47 E4 3 Pass Fe-59 3.64 - 6.46 E4 4.86 E4 4.85 E4 3 Pass Co-60 6.13 - 10.86 E4 8.17 E4 7.80 E4 3 Pass Zn-65 7.44 - 13.19 E4 9.92 E4 9.76 E4 3 Pass Cs-134 3.35 - 5.94 E4 4.47 E4 3.69 E4 3 Pass Cs-137 3.38 - 6.00 E4 4.51 E4 4.11 E4 3 Pass Ce-141 5.41 - 9.59 E4 7.21 E4 6.68 E4 3 Pass Section 5 - Page 5

Gamma in Water 0.25 liter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 2/22/2010 Q101GWR Co-57 0.86 - 1.52 E4 1.14 E4 1.09 E4 3 Pass Co-60 2.72 - 4.82 E3 3.62 E3 3.71 E3 3 Pass Ba-133 5.31 - 9.43 E3 7.09 E3 5.56 E3 3 Pass Cs-137 4.67 - 8.27 E3 6.22 E3 5.88 E3 3 Pass 6/2/2010 Q102GWSL Cr-51 1.15 - 2.05 E5 1.54 E5 1.77 E5 3 Pass Mn-54 4.91 - 8.70 E4 6.54 E4 6.39 E4 3 Pass Co-58 3.10 - 5.49 E4 4.13 E4 4.20 E4 3 Pass Fe-59 3.79 - 6.72 E4 5.05 E4 5.68 E4 3 Pass Co-60 5.63 - 9.99 E4 7.51 E4 7.21 E4 3 Pass Zn-65 6.00 - 10.63 E4 7.99 E4 8.09 E4 3 Pass Cs-134 3.62 - 6.42 E4 4.82 E4 4.09 E4 3 Pass Cs-137 4.29 - 7.61 E4 5.72 E4 5.19 E4 3 Pass Ce-141 3.66 - 6.49 E4 4.88 E4 5.34 E4 3 Pass 9/9/2010 Q103GWSL Cr-51 1.00 - 1.77 E5 1.33 E5 1.35 E5 3 Pass Mn-54 4.34 - 7.69 E4 5.79 E4 5.90 E4 3 Pass Co-58 2.82 - 5.00 E4 3.76 E4 3.67 E4 3 Pass Fe-59 3.64 - 6.46 E4 4.86 E4 5.18 E4 3 Pass Co-60 6.13 - 10.86 E4 8.17 E4 8.25 E4 3 Pass Zn-65 7.44 - 13.19 E4 9.92 E4 10.33 E4 3 Pass Cs-134 3.35 - 5.94 E4 4.47 E4 3.92 E4 3 Pass Cs-137 3.38 - 6.00 E4 4.51 E4 4.33 E4 3 Pass Ce-141 5.41 - 9.59 E4 7.21 E4 7.09 E4 3 Pass Gamma on Filter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi pCi pCi 6/17/2010 E7153-37 Cr-51 2.46 - 4.36 E2 3.28 E2 3.76 E2 2 Pass Mn-54 1.23 - 2.18 E2 1.64 E2 1.65 E2 2 Pass Co-58 7.34 - 13.02 E1 9.79 E1 9.93 E1 2 Pass Fe-59 0.86 - 1.53 E2 1.15 E2 1.05 E2 2 Pass Co-60 1.43 - 2.53 E2 1.90 E2 1.86 E2 2 Pass Zn-65 1.49 - 2.65 E2 1.99 E2 1.92 E2 2 Pass Cs-134 0.92 - 1.62 E2 1.22 E2 1.13 E2 2 Pass Cs-137 1.09 - 1.93 E2 1.45 E2 1.40 E2 2 Pass Ce-141 0.80 - 1.42 E2 1.07 E2 1.01 E2 2 Pass Gamma in Soil (Special Testing)*

Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/kg pCi/kg pCi/kg 12/9/2010 E7380-37 Cr-51 2.60 - 9.98 E2 5.09 E2 5.85 E2 4 Pass Mn-54 1.01 - 1.78 E2 1.34 E2 1.42 E2 4 Pass Co-58 0.76 - 1.34 E2 1.01 E2 0.96 E2 1/4 Low (1)

Fe-59 0.95 - 2.25 E2 1.46 E2 1.42 E2 4 Pass Co-60 2.52 - 4.47 E2 3.36 E2 3.27 E2 4 Pass Zn-65 1.46 - 2.58 E2 1.94 E2 1.97 E2 4 Pass Cs-134 1.31 - 2.33 E2 1.75 E2 1.54 E2 4 Pass Cs-137 2.24 - 3.96 E2 2.98 E2 2.89 E2 4 Pass

  • INOS Audit 10-15(INOS)(REC)(MNS) 2010, PIP M-10-06597 Section 5 - Page 6

Gamma in Vegetation (Special Testing)*

Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/kg pCi/kg pCi/kg 12/9/2010 E7381-37 Cr-51 2.36 - 11.11 E2 5.12 E2 5.10 E2 1 Pass Mn-54 1.01 - 1.78 E2 1.34 E2 1.51 E2 1 Pass Co-58 0.76 - 1.34 E2 1.01 E2 1.00 E2 1 Pass Fe-59 0.84 - 2.57 E2 1.47 E2 1.54 E2 1 Pass Co-60 2.54 - 4.50 E2 3.38 E2 3.38 E2 1 Pass Zn-65 1.46 - 2.59 E2 1.95 E2 2.24 E2 1 Pass Cs-134 1.32 - 2.34 E2 1.76 E2 1.51 E2 1 Pass Cs-137 1.57 - 2.78 E2 2.09 E2 2.03 E2 1 Pass

  • INOS Audit 10-15(INOS)(REC)(MNS) 2010, PIP M-10-06597 Iodine in Milk Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 3/2/2010 Q101LIM1 I-131 2.29 - 4.06 E1 3.06 E1 2.38 E1 1 Pass 3/2/2010 Q101LIM2 I-131 1.25 - 2.21 E3 1.66 E3 1.39 E3 3 Pass 3/2/2010 Q101LIM3 I-131 6.27 - 11.13 E3 8.37 E3 6.44 E3 2 Pass Iodine on Cartridge Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi pCi pCi 6/17/2010 E7154-37 I-131 6.01 - 10.65 E1 8.01 E1 8.39 E1 3 Pass Tritium in Water Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 2/22/2010 Q101TWS1 H-3 6.68 - 11.84 E5 8.91 E5 9.00 E5 3 Pass 2/22/2010 Q101TWS2 H-3 0.79 - 1.40 E7 1.05 E7 1.00 E7 3 Pass 11/4/2010 Q104TWR1 H-3 3.14 - 5.56 E3 4.18 E3 3.91 E3 3 Pass 11/4/2010 Q104TWR2 H-3 3.40 - 6.02 E4 4.53 E4 4.26 E4 3 Pass 11/4/2010 Q104TWR3 H-3 4.98 - 8.83 E2 6.64 E2 6.12 E2 3 Pass Gross Beta in Water Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 11/18/2010 Q104ABW1 Cs-137 5.43 - 9.63 E1 7.24 E1 6.79 E1 3 Pass 11/18/2010 Q104ABW2 Cs-137 4.88 - 8.66 E1 6.51 E1 6.44 E1 3 Pass 11/18/2010 Q104ABW3 Cs-137 1.15 - 2.03 E1 1.53 E1 1.52 E1 3 Pass Section 5 - Page 7

Section 5 - Page 8 Table 5.0-A Footnote Explanations (1)

Gamma in Soil (Special Testing), Sample ID E7380-37, Reference Date 12/9/2010 One of four Co-58 results was biased low and outside of the acceptance range (reference 6.16).

TABLE 5.0-B ENVIRONMENTAL RESOURCE ASSOCIATES (ERA)

QUIK'RESPONSE PROGRAM 2010 PROFICIENCY TEST RESULTS FOR ENRAD LABORATORIES ERA LABORATORY CODE: D242401 Proficiency test samples are received, prepared, analyzed, and reported to Environmental Resource Associates as described in the "Quik" Response instruction package within the study period. Proficiency test data are reported to ERA for evaluation. ERA reports proficiency test results to the North Carolina Department of Health and Human Services, North Carolina Public Drinking Water Laboratory Certification Program.

If applicable, footnote explanations are included following this data table.

Gamma Emitters in Water Reference Sample I.D.

Nuclide Acceptance Reference Reported Proficiency Check Date Range Value Value Status pCi/l pCi/l pCi/l 4/5/2010 RAD-81*

Ba-133 5.49 - 7.25 E1 6.59 E1 7.26 E1 High (1)

Cs-134 5.84 - 7.88 E1 7.16 E1 6.74 E1 Pass Cs-137 1.31 - 1.63 E2 1.46 E2 1.33 E2 Pass Co-60 7.60 - 9.53 E1 8.45 E1 8.40 E1 Pass Zn-65 1.67 - 2.19 E2 1.86 E2 1.93 E2 Pass 1/10/2010 Quik 120810K**

Ba-133 6.10 - 8.02 E1 7.29 E1 7.75 E1 Pass Cs-134 5.15 - 6.97 E1 6.34 E1 6.18 E1 Pass Cs-137 1.08 - 1.34 E2 1.20 E2 1.14 E2 Pass Co-60 8.10 - 10.1 E1 9.00 E1 9.90 E1 Pass Zn-65 1.89 - 2.46 E2 2.10 E2 2.12 E2 Pass Tritium in Water Reference Sample I.D.

Nuclide Acceptance Reference Reported Proficiency Check Date Range Value Value Status pCi/l pCi/l pCi/l 4/5/2010 RAD-81*

H-3 1.08 - 1.36 E4 1.24 E4 1.16 E4 Pass 1/10/2010 Quik 120810K**

H-3 3.16 - 4.10 E3 3.72 E3 3.58 E3 Pass

  • ERA study period 4/5/2010 - 5/20/2010, ERA data report issue date 5/26/2010
    • ERA study period 12/8/2010 - 3/30/2011, ERA data report issue date 3/30/2010 Section 5 - Page 9

Section 5 - Page 10 Table 5.0-B Footnote Explanations (1)

Gamma Emitters in Water, Sample ID RAD-81, Reference Date 4/5/2010 Reported result for Ba-133 was above the acceptance range limit (reference 6.17).

TABLE 5.0-C 2010 ENVIRONMENTAL DOSIMETER CROSS-CHECK RESULTS Nuclear Technology Services 1st Quarter 2010 2nd Quarter 2010 TLD Reported Delivered Bias Pass/Fail TLD Reported Delivered Bias Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail 102379 105.0 101.9 3.04

<+/-15%

Pass 102501 71.0 73.0

-2.74

<+/-15%

Pass 102385 103.0 101.9 1.08

<+/-15%

Pass 102013 73.0 73.0 0.00

<+/-15%

Pass 102403 103.0 101.9 1.08

<+/-15%

Pass 100309 73.0 73.0 0.00

<+/-15%

Pass 102480 101.0 101.9

-0.88

<+/-15%

Pass 100623 70.0 73.0

-4.11

<+/-15%

Pass 102505 103.0 101.9 1.08

<+/-15%

Pass 102060 72.0 73.0

-1.37

<+/-15%

Pass Average Bias (B) 1.08 Average Bias (B)

-1.64 Standard Deviation (S) 1.39 Standard Deviation (S) 1.79 Measure Performance lBl+S 2.47

<15%

Pass Measure Performance lBl+S 3.43

<15%

Pass 3rd Quarter 2010 4th Quarter 2010 TLD Reported Delivered Bias Pass/Fail TLD Reported Delivered Bias Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail 100252 56.1 55.9 0.36

<+/-15%

Pass 102367 88.0 84.0 4.76

<+/-15%

Pass 100403 55.2 55.9

-1.25

<+/-15%

Pass 102399 91.0 84.0 8.33

<+/-15%

Pass 101143 55.3 55.9

-1.07

<+/-15%

Pass 102402 87.0 84.0 3.57

<+/-15%

Pass 100065 54.2 55.9

-3.04

<+/-15%

Pass 102480 90.0 84.0 7.14

<+/-15%

Pass 100054 57.2 55.9 2.33

<+/-15%

Pass 102510 90.0 84.0 7.14

<+/-15%

Pass Average Bias (B)

-0.54 Average Bias (B) 6.19 Standard Deviation (S) 2.00 Standard Deviation (S) 1.96 Measure Performance lBl+S 2.54

<15%

Pass Measure Performance lBl+S 8.15

<15%

Pass Section 5 - Page 11

Internal Crosscheck (Duke Energy) 1st Quarter 2010 2nd Quarter 2010 TLD Reported Delivered Bias Pass/Fail TLD Reported Delivered Bias Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail 102384 21.5 22.0

-2.18

<+/-15%

Pass 101183 29.2 30.0

-2.60

<+/-15%

Pass 102399 21.4 22.0

-2.82

<+/-15%

Pass 100709 29.8 30.0

-0.70

<+/-15%

Pass 102406 21.9 22.0

-0.50

<+/-15%

Pass 101167 29.0 30.0

-3.30

<+/-15%

Pass 102487 20.5 22.0

-6.68

<+/-15%

Pass 101290 28.2 30.0

-6.07

<+/-15%

Pass 102260 21.1 22.0

-4.27

<+/-15%

Pass 100027 28.2 30.0

-6.07

<+/-15%

Pass 102504 21.2 22.0

-3.45

<+/-15%

Pass 101310 28.6 30.0

-4.67

<+/-15%

Pass 102393 20.8 22.0

-5.45

<+/-15%

Pass 101189 29.6 30.0

-1.33

<+/-15%

Pass 102261 21.2 22.0

-3.68

<+/-15%

Pass 101158 29.7 30.0

-1.03

<+/-15%

Pass 102343 20.9 22.0

-5.09

<+/-15%

Pass 101386 31.0 30.0 3.47

<+/-15%

Pass 101235 21.5 22.0

-2.36

<+/-15%

Pass 101398 32.4 30.0 8.03

<+/-15%

Pass Average Bias (B)

-3.65 Average Bias (B)

-1.43 Standard Deviation (S) 1.81 Standard Deviation (S) 4.38 Measure Performance lBl+S 5.46

<15%

Pass Measure Performance lBl+S 5.81

<15%

Pass 3rd Quarter 2010 4th Quarter 2010 TLD Reported Delivered Bias Pass/Fail TLD Reported Delivered Bias Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail Number (mR)

(mR)

(% diff)

Criteria Pass/Fail 102264 96.8 100.0

-3.21

<+/-15%

Pass 102301 33.1 35.0

-5.46

<+/-15%

Pass 102406 101.4 100.0 1.41

<+/-15%

Pass 102471 34.8 35.0

-0.49

<+/-15%

Pass 102399 99.7 100.0

-0.30

<+/-15%

Pass 102083 33.7 35.0

-3.66

<+/-15%

Pass 102403 97.0 100.0

-2.97

<+/-15%

Pass 102442 33.4 35.0

-4.60

<+/-15%

Pass 102480 98.8 100.0

-1.17

<+/-15%

Pass 102389 33.4 35.0

-4.46

<+/-15%

Pass 102505 99.0 100.0

-1.00

<+/-15%

Pass 102362 33.9 35.0

-3.20

<+/-15%

Pass 102440 95.1 100.0

-4.95

<+/-15%

Pass 101413 33.4 35.0

-4.66

<+/-15%

Pass 102479 95.7 100.0

-4.33

<+/-15%

Pass 102007 33.1 35.0

-5.57

<+/-15%

Pass 101136 98.2 100.0

-1.84

<+/-15%

Pass 102509 34.9 35.0

-0.31

<+/-15%

Pass 102339 95.6 100.0

-4.41

<+/-15%

Pass 102058 33.2 35.0

-5.23

<+/-15%

Pass Average Bias (B)

-2.28 Average Bias (B)

-3.76 Standard Deviation (S) 2.05 Standard Deviation (S) 1.92 Measure Performance lBl+S 4.33

<15%

Pass Measure Performance lBl+S 5.68

<15%

Pass Section 5 - Page 12

Section 6 - Page 1

6.0 REFERENCES

6.1 McGuire Selected License Commitment Manual 6.2 McGuire Technical Specifications 6.3 McGuire Updated Final Safety Analysis Report 6.4 McGuire Offsite Dose Calculation Manual 6.5 McGuire Annual Radiological Environmental Operating Report 1979 - 2009 6.6 McGuire Annual Radioactive Effluent Release Report 2010 6.7 Probability and Statistics in Engineering and Management Science, Hines and Montgomery, 1969, pages 287-293.

6.8 Practical Statistics for the Physical Sciences, Havilcek and Crain, 1988, pages 83-93.

6.9 Nuclear Regulatory Commission Regulatory Guide 1.109, Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purposes of Evaluating Compliance with 10CFR50, Appendix I.

6.10 EnRad Laboratories Operating Procedures 6.11 RETDAS, Radiological Effluent Tracking and Dose Assessment Software, Canberra Version 3.5.1, DPC Revision #4.0 6.12 NRC Integrated Inspection Report (50-369/2009004, 50-370/2009004) 6.13 Duke Energy Corporation EnRad Laboratory Charcoal Cartridge Study, performed 2001 6.14 Radiological Effluents Controls INOS Audit 10-15(INOS)(REC)(MNS) 6.15 Problem Investigation Program Database, V 3.4.1, Duke Energy Company, M-10-06597 6.16 Problem Investigation Program Database, V 3.4.1, Duke Energy Company, G-11-00581 6.17 Problem Investigation Program Database, V 3.4.1, Duke Energy Company, G-11-00598 6.18 Problem Investigation Program Database, V 3.4.1, Duke Energy Company, G-09-01290 6.19 Problem Investigation Program Database, V 3.4.1, Duke Energy Company, G-10-00780 6.20 Nuclear System Directive (NSD) 701, Records Management

Appendix A - Page 1 APPENDIX A ENVIRONMENTAL SAMPLING ANALYSIS PROCEDURES

Appendix A - Page 2 APPENDIX A ENVIRONMENTAL SAMPLING AND ANALYSIS PROCEDURES Adherence to established procedures for sampling and analysis of all environmental media at McGuire Nuclear Station was required to ensure compliance with Station Selected Licensee Commitments. Analytical procedures were employed to ensure that Selected Licensee Commitments detection capabilities were achieved.

Environmental sampling and analyses were performed by EnRad Laboratories, Dosimetry and Records, and Fisheries and Aquatic Ecology.

This appendix describes the environmental sampling frequencies and analysis procedures by media type.

I. CHANGE OF SAMPLING PROCEDURES TLD Location 178 (Special Interest) distance was updated from SE sector 9.32 miles to 9.36 miles as a result of assessment RP-SA-2009-0024 (reference 6.18).

TLD Location 190 (Site Boundary TLD) was relocated due to onsite construction.

Distance updated from WSW sector 0.33 miles to 0.37 miles (reference 6.19).

II. DESCRIPTION OF ANALYSIS PROCEDURES Gamma spectroscopy analyses are performed using high purity germanium gamma detectors and Canberra analytical software. Designated sample volumes are transferred to appropriate counting geometries and analyzed by gamma spectroscopy. Perishable samples such as fish and broadleaf vegetation are ground to achieve a homogeneous mixture. Soils and sediments are dried, sifted to remove foreign objects (rocks, clams, glass, etc.) then transferred to appropriate counting geometry.

Low-level iodine analyses are performed by passing a designated sample aliquot through a pre-weighed amount of ion exchange resin to remove and concentrate any iodine in the aqueous sample (milk). The resin is then dried, mixed thoroughly, and a net resin weight determined before being transferred to appropriate counting geometry and analyzed by gamma spectroscopy.

Tritium analyses are performed quarterly by using low-level environmental liquid scintillation analysis technique on a Packard 2550 liquid scintillation system or Perkin-Elmer 2900TR liquid scintillation system. Tritium samples are distilled and batch processed with a tritium

Appendix A - Page 3 spike and blank to verify instrument performance and sample preparation technique are acceptable.

Gross beta analysis is performed by concentrating a designated aliquot of sample precipitate and analyzing by Tennelec XLB Series 5 gas-flow proportional counters. Samples are batch processed with a blank to ensure sample contamination has not occurred.

III.

CHANGE OF ANALYSIS PROCEDURES No analysis procedures were changed during 2010.

IV.

SAMPLING AND ANALYSIS PROCEDURES A.1 AIRBORNE PARTICULATE AND RADIOIODINE Airborne particulate and radioiodine samples at each of seven locations were composited continuously by means of continuous air samplers. Air particulates were collected on a particulate filter and radioiodines were collected in a charcoal cartridge positioned behind the filter in the sampler. The samplers are designed to operate at a constant flow rate (in order to compensate for any filter loading) and are set to sample approximately 2 cubic feet per minute. Filters and cartridges were collected weekly.

A separate weekly gamma analysis was performed on each charcoal cartridge and air particulate. A weekly gross beta analysis was performed on each filter. The continuous composite samples were collected from the locations listed below.

Location 102

=

Amity Church Road (9.89 mi. WNW)

Location 103

=

Cottonwood (4.20 mi. NE)

Location 120

=

Site Boundary (0.46 mi. NNE)

Location 121

=

Site Boundary (0.47 mi. NE)

Location 125

=

Site Boundary (0.38 mi. SW)

Location 133

=

Cornelius (6.23 mi. ENE)

Location 195

=

Fishing Access Road (0.19 mi. N)

A.2 DRINKING WATER Monthly composite samples were collected. A gross beta and gamma analysis was performed on monthly composites. Tritium analysis was performed on the quarterly composites. The composites were collected monthly from the locations listed below.

Location 101 = North Mecklenburg Water Treatment Facility (3.31 mi E)

Location 119 = Mt. Holly Municipal Water Supply (7.40 mi. SSW)

Location 132 = Charlotte Municipal Water Supply (11.1 mi. SSE)

Location 136 = Mooresville Municipal Water Supply (12.7 mi. NNE)

Location 194 = East Lincoln County Water Supply (6.73 mi. NNW)

Appendix A - Page 4 A.3 SURFACE WATER Monthly composite samples were collected. A gamma analysis was performed on the monthly composites. Tritium analysis was performed on the quarterly composites sample. The composites were collected monthly from the locations listed below.

Location 128

=

Discharge Canal Bridge (0.45 mi. NE)

Location 131

=

Cowans Ford Dam (0.64 mi. WNW)

Location 135

=

Plant Marshall Intake Canal (11.9 mi. N)

A.4 MILK Biweekly grab samples were collected at one location. A gamma and low-level Iodine-131 analysis was performed on each sample. The biweekly grab samples were collected from the location listed below.

Location 141

=

Lynch Dairy - Cows (14.8 mi. WNW)

A.5 BROADLEAF VEGETATION Monthly samples were collected as available and a gamma analysis was performed on each sample. The samples were collected from the locations listed below.

Location 102

=

Amity Church Road (9.89 mi. WNW)

Location 120

=

Site Boundary (0.46 mi. NNE)

Location 125

=

Site Boundary (0.38 mi. SW)

Location 193

=

Site Boundary (0.19 mi. N)

A.6 FOOD PRODUCTS Samples were collected monthly when available during the harvest season and a gamma analysis was performed on each. The samples were collected at the location listed below.

Location 188 = 5 mile radius Gardens (2.79 mi NNE)

Appendix A - Page 5 A.7 FISH Semiannual samples were collected and a gamma analysis was performed on the edible portions of each sample. Boney fish (i.e. Sunfish) were prepared whole minus the head and tail portions. The samples were collected from the locations listed below.

Location 129

=

Discharge Canal Entrance to Lake Norman (0.51 mi. ENE)

Location 137

=

Pinnacle Access Area (12.0 mi. N)

A.8 SHORELINE SEDIMENT Semiannual samples were collected and a gamma analysis was performed on each following the drying and removal of rocks and clams. The samples were collected from the locations listed below.

Location 129

=

Discharge Canal Entrance to Lake Norman (0.51 mi. ENE)

Location 130

=

Highway 73 Bridge Downstream (0.52 mi. SW)

Location 137

=

Pinnacle Access Area (12.0 mi. N)

A.9 DIRECT GAMMA RADIATION (TLD)

Thermoluminescent dosimeters (TLD) were collected quarterly at forty-one locations.

A gamma exposure rate was determined for each TLD. TLD locations are listed in Table 2.1-B. The TLDs were placed as indicated below.

An inner ring of 14 TLDs at the site boundary, one in each available meteorological sector. The site boundary locations in the N and NNW sectors are over water; however, two special interest TLD's were placed in these sectors inside the site boundary in March, 1991.

An outer ring of 16 TLDs, one in each meteorological sector in the 6 to 8 kilometer range.

The remaining TLDs were placed in special interest areas such as population centers, residential areas, schools, and control locations.

A.10 ANNUAL LAND USE CENSUS An annual Land Use Census was conducted to identify within a distance of 8 kilometers (5.0 miles) from the station, the nearest location from the site boundary in each of the sixteen meteorological sectors, the following:

The Nearest Residence The Nearest Garden greater than 50 square meters or 500 square feet The Nearest Milk-giving Animal (cow, goat, etc.)

Appendix A - Page 6 The census was conducted during the growing season on 5/19/2010. Results are shown in Table 3.10. No changes were made to the sampling procedures during 2010 as a result of the 2010 census.

In the environmental program, the air deposition parameters (D/Q) are used to determine air, broadleaf vegetation and milk sampling locations. McGuires sectors with the three highest values did not change in 2010.

V.

GLOBAL POSITIONING SYSTEM (GPS) ANALYSIS The McGuire site centerline used for GPS measurements was referenced from the McGuire Nuclear Station Updated Final Safety Analysis Report (UFSAR), section 2.1.1, Site Location. Waypoint coordinates used for MNS GPS measurements were latitude 35°-25'-59"N and longitude 80°-56'-55"W. Maps and tables were generated using North American Datum (NAD) 27. Data normally reflect accuracy to within 2 to 5 meters from point of measurement. GPS field measurements were taken as close as possible to the item of interest. Distances for the locations are displayed using three significant figures.

Appendix B - Page 1 APPENDIX B RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

OF RESULTS 2010

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No. 50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No.of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Air Particulate 102 (9.89 mi WNW)

(pCi/m3)

BETA 371 1.00E-02 1.93E-2 (318/318) 103 2.01E-2 (53/53) 1.95E-2 (53/53) 0 7.53E 3.56E-2 (4.20 mi NE) 1.21E 3.23E-2 9.59E 3.40E-2 CS-134 371 5.00E-02 0.00 (0/318) 0.00 (0/53) 0.00 (0/53) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 371 6.00E-02 0.00 (0/318) 0.00 (0/53) 0.00 (0/53) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 371 7.00E-02 0.00 (0/318) 0.00 (0/53) 0.00 (0/53) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:55 Appendix B - Page 2

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Air Radioiodine 102 (9.89 mi WNW)

(pCi/m3)

CS-134 371 5.00E-02 0.00 (0/318) 0.00 (0/53) 0.00 (0/53) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 371 6.00E-02 0.00 (0/318) 0.00 (0/53) 0.00 (0/53) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 371 7.00E-02 0.00 (0/318) 0.00 (0/53) 0.00 (0/53) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:55 Appendix B - Page 3

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Drinking Water 136 (pCi/liter)

(12.7 mi NNE)

BALA-140 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 BETA 65 4

1.78 (50/52) 101 1.85 (13/13) 1.74 (12/13) 0 0.83 - 2.68 (3.31 mi E) 1.08 - 2.57 1.12 - 2.37 CO-58 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 65 18 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 FE-59 65 30 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 H-3 20 2000 503 (13/16) 101 720 (4/4) 0.00(0/0) 0 176 - 1210 (3.31 mi E) 474 - 1210 0.00 - 0.00 I-131 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 NB-95 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 65 30 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZR-95 65 15 0.00 (0/52) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:55 Appendix B - Page 4

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Surface Water 135 (pCi/liter)

(11.9 mi N)

BALA-140 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-58 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 39 18 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 FE-59 39 30 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 H-3 12 2000 740 (8/8) 128 1090 (4/4) 0.00 (0/4) 0 242 - 1790 (0.45 mi NE) 528 - 1790 0.00 - 0.00 I-131 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 NB-95 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 39 30 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZR-95 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:56 Appendix B - Page 5

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Milk NO INDICATOR 141 (pCi/liter)

LOCATION (14.8 mi WNW)

BALA-140 26 15 0.00 (0/26) 0.00 (0/26) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 26 15 0.00 (0/26) 0.00 (0/26) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 26 18 0.00 (0/26) 0.00 (0/26) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 26 15 0.00 (0/26) 0.00 (0/26) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 LLI-131 26 1

0.00 (0/26) 0.00 (0/26) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:57 Appendix B - Page 6

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Broadleaf 102 (9.89 mi WNW)

Vegetation (pCi/kg-wet)

CS-134 48 60 0.00 (0/36) 0.00 (0/12) 0.00 (0/12) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 48 80 0.00 (0/36) 0.00 (0/12) 0.00 (0/12) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 48 60 0.00 (0/36) 0.00 (0/12) 0.00 (0/12) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:57 Appendix B - Page 7

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Food Products NO CONTROL (pCi/kg-wet)

LOCATION CS-134 12 60 0.00 (0/12) 0.00 (0/12) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 12 80 0.00 (0/12) 0.00 (0/12) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 12 60 0.00 (0/12) 0.00 (0/12) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:57 Appendix B - Page 8

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Fish 137 (pCi/kg-wet)

(12.0 mi N)

CO-58 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 12 150 23.3 (1/6) 129 23.3 (1/6) 13.2 (1/6) 0 23.3 - 23.3 (0.51 mi ENE) 23.3 - 23.3 13.2 - 13.2 FE-59 12 260 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 12 260 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:58 Appendix B - Page 9

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Shoreline 137 Sediment (12.0 mi N)

(pCi/kg-dry)

MN-54 6

0 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-58 6

0 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 6

0 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 6

150 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 6

180 75.8 (2/4) 130 75.8 (2/2) 0.00 (0/2) 0 31.6 - 120 (0.52 mi SW) 31.6 - 120 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements If LLD is equal to 0.00, then the LLD is not required by Selected Licensee Commitments Report Generated @ 5/4/2011 15:58 Appendix B - Page 10

Environmental Radiological Monitoring Program Summary Facility: McGuire Nuclear Station Docket No.

50-369,370 Location: Mecklenburg County, North Carolina Report Period: 01-JAN-2010 to 31-DEC-2010 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Direct Radiation 175 TLD (15.5 mi WNW)

(mR/standard quarter) 163 0.00E+00 17.0 (159/159) 180 27.0 (4/4) 22.3 (4/4) 0 10.0 - 30.0 (12.7 mi NNE) 25.0 - 30.

20.0 - 25.0 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 5/4/2011 15:59 Appendix B - Page 11

Appendix C - Page 1 APPENDIX C SAMPLING DEVIATIONS UNAVAILABLE ANALYSES

Appendix C - Page 2 APPENDIX C MCGUIRE NUCLEAR STATION SAMPLING DEVIATIONS & UNAVAILABLE ANALYSES DEVIATION & UNAVAILABLE REASON CODES BF Blown Fuse PO Power Outage FZ Sample Frozen PS Pump out of service / Undergoing Repair IW Inclement Weather SL Sample Loss/Lost due to Lab Accident LC Line Clog to Sampler SM Motor / Rotor Seized OT Other TF Torn Filter PI Power Interrupt VN Vandalism PM Preventive Maintenance CN Construction C.1 SAMPLING DEVIATIONS Air Particulate and Air Radioiodines Location Scheduled Collection Dates Actual Collection Dates Reason Code Corrective Action 103 1/18 - 1/25/2010 1/18 - 1/25/2010 PI Power to equipment was interrupted for about 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during composite period.

Suspected cause inclement weather.

Drinking Water Location Scheduled Collection Dates Actual Collection Dates Reason Code Corrective Action 119 6/1 - 6/28/2010 6/1 - 6/28/2010 LC Collection reservoir supply line clogged.

Line clog removed and flow restored.

Grab sample taken at time of collection.

Normal sampling resumed 6/28/2010.

Surface Water Location Scheduled Collection Dates Actual Collection Dates Reaso n

Code Corrective Action 128 6/28 - 7/26/2010 6/28 - 7/26/2010 PS Power to sampling equipment interrupted.

Work request 81510 written. Grab sample taken. Maintenance personnel found lightning strike damage to power supply.

Submersible pump and components replaced and normal sampling resumed.

135 11/15 - 12/13/2010 11/15 - 12/13/2010 PO Power outage to sampling equipment.

Work request 85922 written. Grab sample taken. Power outage estimated to be about 1 day based on available sample volume.

Appendix C - Page 3 C.2 UNAVAILABLE ANALYSES TLD Location Scheduled Collection Dates Reason Code Corrective Action 161 6/17 - 9/16/2010 CN TLD missing. 4th quarter 2010 TLD placed in field.

Appendix D - Page 1 APPENDIX D ANALYTICAL DEVIATIONS No Analytical deviations were incurred for the 2010 Radiological Environmental Monitoring Program

Appendix E - Page 1 APPENDIX E RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM RESULTS This appendix includes sample analysis reports and supportive data generated from each sample medium. Appendix E is located separately from this report and is permanently archived in the Nuclear Electronic Document Library (NEDL) as described in reference 6.20.