Duke Duke Energy Corporation McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, NC 28078-9340 H. B. Barron (704)875-4800 OFFiCE Vice President (704)875-4809 FAX April 24, 2002 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555
Subject:
McGuire Nuclear Station Docket Nos. 50-369 and 50-370 Annual Radioactive Effluent Release Report Pursuant to the requirements of Technical Specification 5.6.3 and 16.11-16.2 of the McGuire Selected Licensee Commitments Manual, attached is the Annual Radioactive Effluent Release Report.
- Technical Specification 5.6.1 .c requires the Offsite Dose Calculation Manual (ODCM) to be submitted as a part of or concurrent with the Radioactive Effluent Release Report.
Attached is a CD copy of the 2002 ODCM. No changes were made to the Process Control Program (PCP) during this reporting period.
Technical Specification 5.5.5.b.3 requires a complete, legible copy of Section 16.11 of the UFSAR to be submitted as a part of or concurrent with the Radioactive Effluent Release Report. Attachment 6 is included to meet this requirement.
The following Attachments form the contents of the report:
Attachment 1 Radioactive Effluent Releases and Supplemental Information Attachment 2 Solid Waste Disposal Report Attachment 3 Unplanned Offsite Releases Attachment 4 Fuel Cycle Calculation Attachment 5 Inoperable Monitoring Equipment Attachment 6 UFSAR Section 16.11 There are no regulatory commitments contained in this correspondence. Dirke Energy is not requesting any NRC staff review of this report.
Questions concerning this report should be directed to Kay Crane at (704) 875-4306.
H. B. Barron a4 0
NRC Document Control Desk Page 2 cc: Mr. Bob Martin, Project Manager Office of Nuclear Reactor Regulation Mail Stop 08D12 Washington, D.C. 20555 Mr. Luis Reyes, Regional Administrator U. S. Nuclear Regulatory Commission Region II Atlanta Federal Center 61 Forsyth Street - Suite 23T85 Atlanta, GA 30323 Mr. R. M. Frye, Director Division of Radiation Protection State of North Carolina 3825 Barrett Drive Raleigh, N.C. 27609-7221 American Nuclear Insurers Town Center, Suite 300S 29 South Main Street West Hartford, CT 06107-2445 Mr. Scott Shaeffer Senior Resident Inspector McGuire Nuclear Station
Attachment 1 Radioactive Effluent Releases and Supplemental Information
McGUIRE NUCLEAR STATION EFFLUENT RELEASE DATA (January 1, 2001 through December 31, 2001)
This attachment includes a summary of the quantities of radioactive liquid and gaseous effluents as outlined in Regulatory Guide 1.21, Appendix B.
TABLE lA EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR A. Fission and Activation Gases
- 1. Total Release Ci 1.15E+00 1.07E+00 1.25E+00 1.34E+00 4.81E+00
- 2. Avg. Release Rate pCi/sec 1.48E-01 1.36E-01 1.58E-01 1.69E-01 1.53E-01 B. Iodine-131
- 1. Total Release Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 2. Avg. Release Rate pCi/sec 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 C. Particulates Half Life >= 8 days
- 1. Total Release Ci 5.48E-06 0.OOE+00 0.OOE+00 0.OOE+00 5.48E-06
- 2. Avg. Release Rate pCi/sec 7.05E-07 0.OOE+00 0.OOE+00 0.OOE+00 1.74E-07 D. Tritium
- 1. Total Release Ci 4.72E+01 5.02E+01 3.26E+01 6.19E+01 1.92E+02
- 2. Avg. Release Rate pCi/sec 6.07E+00 6.38E+00 4.10E+00 7.79E+00 6.08E+00
-S
TABLE lB EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS - ELEVATED RELEASES - CONTINUOUS MODE McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR
- 1. Fission and Activation Gases
- No Nuclide Activities **
- 2. lodines
- No Nuclide Activities **
- 3. Particulates Half Life >= 8 days
- No Nuclide Activities **
- 4. Tritium
- No Nuclide Activities **
TABLE lB EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS - ELEVATED RELEASES - BATCH MODE McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR
- 1. Fission and Activation Gases
- No Nuclide Activities **
- 2. lodines
- No Nuclide Activities **
- 3. Particulates Half Life >= 8 days
- No Nuclide Activities **
- 4. Tritium
- No Nuclide Activities **
TABLE IC EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS - GROUND RELEASES - CONTINUOUS MODE McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR
- 1. Fission and Activation Gases
- No Nuclide Activities **
- 2. lodines Ci 0.00E+00 2.24E-05 0.001E+00 0.00E+00 2.24E-05 1-133 Ci 0.00E+00 2.24E-05 0.001E+00 0.001E+00 2.24E-05 Totals for Period...
- 3. Particulates Half Life >= 8 days Ci 5.48E-06 0.001E+00 0.00E+00 0.001E+00 5.48E-06 CO-58 Ci 5.48E-06 0.001E+00 0.00E+00 0.001E+00 5.48E-06 Totals for Period...
- 4. Tritium Ci 4.69E+01 4.95E+01 3.19E+01 6.12E+01 1. 90E+02 H-3 Ci 4.69E+01 4.95E+01 3.19E+01 6.12E+01 1. 90E+02 Totals for Period...
TABLE IC EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS - GROUND RELEASES - BATCH MODE McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR
- 1. Fission and Activation Gases AR-41 Ci 9.68E-01 9.OOE-01 1.14E+00 1.23E+00 4.24E+00 KR-85 Ci 2.44E-02 8.29E-03 0.OOE+00 0. OOE+00 3.27E-02 XE-131M Ci 1.73E-02 0. OOE+00 0. OOE+00 0. OOE+00 1.73E-02 XE-133 Ci 1.25E-01 1.43E-01 1. 03E-01 9.23E-02 4.63E-01 XE-135 Ci 1.42E-02 2.08E-02 1. 46E-02 1. 43E-02 6.38E-02 Totals for Period... Ci 1.15E+00 1. 07E+00 1.26E+00 1.34E+00 4.82E+00
- 2. Iodines
- No Nuclide Activities **
- 3. Particulates Half Life >= 8 days
- No Nuclide Activities **
- 4. Tritium H-3 Ci 2.53E-01 6. 46E-01 6.98E-01 7.17E-01 2.31E+00 Totals for Period... Ci 2.53E-01 6.46E-01 6.98E-01 7.17E-01 2.31E+00
TABLE 2A EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR A. Fission and Activation Products
- 1. Total Release Ci 6.97E-02 3.22E-02 1.42E-02 7.89E-03 1.24E-01
- 2. Average Diluted Concentration
- a. Continuous Releases pCi/ml 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- b. Batch Releases pCi/ml 9.70E-11 3.49E-11 1.39E-l1 7.89E-12 3.39E-11 B. Tritium
- 1. Total Release Ci 1.82E+02 7.34E+01 1.47E+02 1.35E+02 5.37E+02
- 2. Average Diluted Concentration
- a. Continuous Releases pCi/ml 5.36E-09 6.03E-09 2.85E-09 7.08E-09 5.30E-09
- b. Batch Releases pCi/ml 2.53E-07 7.89E-08 1.44E-07 1.34E-07 1.46E-07 C. Dissolved and Entrained Gases
- 1. Total Release Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 2. Average Diluted Concentration
- a. Continuous Releases pCi/ml 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- b. Batch Releases iCi/ml 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 D. Gross Alpha Radioactivity
- 1. Total Release Ci 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00
- 2. Average Diluted Concentration
- a. Continuous Releases pCi/ml 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- b. Batch Releases pCi/ml 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 E. Volume of Liquid Waste
- 1. Continuous Releases liters 2.08E+07 5.41E+07 5.44E+07 7.68E+07 2.06E+08
- 2. Batch Releases liters 1.87E+07 4.76E+06 1.86E+06 5.32E+05 2.58E+07 F. Volume of Dilution Water
- 1. Continuous Releases liters 7.18E+10 9.24E+i0 1.02E+ll 1.OOE+ll 3.66E+11
- 2. Batch Releases liters 7.18E+ll 9.24E+ll 1.02E+12 1.OOE+12 3.66E+12
TABLE 2B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID EFFLUENTS - CONTINUOUS MODE McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR
- 1. Fission and Activation Products
- No Nuclide Activities **
- 2. Tritium H-3 Ci 3.85E-01 5.57E-01 2.91E-01 7.09E-01 1. 94E+00 Totals for Period... Ci 3.85E-01 5.57E-01 2.91E-01 7.09E-01 1.94E+00
- 3. Dissolved and Entrained Gases
- No Nuclide Activities **
- 4. Gross Alpha Radioactivity
- No Nuclide Activities **
TABLE 2B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID EFFLUENTS - BATCH MODE McGuire Nuclear Station Units 1 & 2 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR
- 1. Fission and Activation Products AG-108M Ci 0.OOE+00 0. OOE+00 0. 00E+00 2.69E-05 2.69E-05 AG-I1OM Ci 7. 72E-05 6.20E-04 4.79E-05 8.29E-04 1.57E-03 BR-82 Ci 9. 84E-07 0. OOE+00 0.00E+00 0.00E+00 9.84E-07 CO-57 Ci 1. 97E-04 1. 01E-04 7.80E-05 0.00E+00 3.76E-04 CO-58 Ci 5. 78E-02 2. 21E-02 1. 02E-02 6.49E-04 9.07E-02 CO-60 Ci 3.26E-03 3.05E-03 1. 26E-03 1. 33E-03 8.90E-03 CR-51 Ci 1. 79E-03 2. 43E-03 0. 00E+00 4.16E-05 4.26E-03 CS-134 Ci 2.99E-05 9.40E-05 1. 79E-05 2. 96E-05 1. 71E-04 CS-137 Ci 1. 75E-03 1.21E-03 2. 97E-04 5.58E-04 3.81E-03 FE-59 Ci 3.43E-05 8.34E-05 0. 00E+00 0.00E+00 1. 18E-04 1-131 Ci 3.39E-07 0. 00E+00 0. 00E+00 0.00E+00 3.39E-07 MN-54 Ci 1. 83E-04 2.30E-04 3.59E-05 9.44E-05 5.44E-04 NA-24 Ci 0. OOE+00 1.80E-06 0. 00E+00 0.OOE+00 1.80E-06 NB-95 Ci 6.53E-05 1. 13E-04 0.OOE+00 0.00E+00 1. 78E-04 NB-97 Ci 1. 16E-05 4. 82E-06 4.54E-06 2.86E-06 2.38E-05 SB-124 Ci 0. 00E+00 2.85E-06 0.00E+00 0.00E+00 2.85E-06 SB-125 Ci 4. 48E-03 2.08E-03 2.21E-03 4.33E-03 1.31E-02 SR-92 Ci 0. OOE+00 6.27E-06 0.00E+00 5.16E-06 1. 14E-05 ZR-95 Ci 4. 14E-05 8. 53E-05 0.00E+00 0.00E+00 1.27E-04 ZR-97 Ci 1. 24E-06 0. OOE+00 0.00E+00 2.73E-06 3.97E-06 Totals for Period... Ci 6.97E-02 3.22E-02 1.42E-02 7.90E-03 1.24E-01
- 2. Tritium H-3 Ci 1.82E+02 7.29E+01 1.46E+02 1. 34E+02 5.35E+02 Totals for Period... Ci 1.82E+02 7.29E+01 1.46E+02 1.34E+02 5. 35E+02
- 3. Dissolved and Entrained Gases
- No Nuclide Activities **
- 4. Gross Alpha Radioactivity
- No Nuclide Activities **
McGUIRE NUCLEAR STATION SUPPLEMENTAL INFORMATION
McGUIRE NUCLEAR STATION 2001 EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION I. REGULATORY LIMITS - PER UNIT A. NOBLE GASES - AIR DOSE B. LIQUID EFFLUENTS - DOSE
- 1. CALENDAR QUARTER - GAMMA DOSE = 5 MRAD 1. CALENDAR QUARTER - TOTAL BODY DOSE = 1.5 MREM
- 2. CALENDAR QUARTER - BETA DOSE = 10 MRAD 2. CALENDAR QUARTER - ORGAN DOSE = 5 MREM
- 3. CALENDAR YEAR - GAMMA DOSE = 10 MRAD 3. CALENDAR YEAR - TOTAL BODY DOSE = 3 MREM
- 4. CALENDAR YEAR - BETA DOSE = 20 MRAD 4. CALENDAR YEAR - ORGAN DOSE = 10 MREM C. IODINE - 131 AND 133, TRITIUM, PARTICULATES W/T 1/2 > 8 DAYS - ORGAN DOSE
- 1. CALENDAR QUARTER = 7.5 MREM
- 2. CALENDAR YEAR = 15 MREM II. MAXIMUM PERMISSIBLE EFFLUENT CONCENTRATIONS A. GASEOUS EFFLUENTS - INFORMATION FOUND IN OFFSITE DOSE CALCULATION MANUAL B. LIQUID EFFLUENTS - INFORMATION FOUND IN 10CFR20, APPENDIX B, TABLE 2, COLUMN 2 III. AVERAGE ENERGY - NOT APPLICABLE IV. MEASUREMENTS AND APPROXIMATIONS OF TOTAL RADIOACTIVITY INFORMATION FOUND IN OFFSITE DOSE CALCULATION MANUAL V. BATCH RELEASES A. LIQUID EFFLUENT
- 1. 2.15E+02 = TOTAL NUMBER OF BATCH RELEASES
- 2. 2.13E+05 = TOTAL TIME (MIN.) FOR BATCH RELEASES.
- 3. 4.19E+04 = MAXIMUM TIME (MIN.) FOR A BATCH RELEASE.
- 4. 9.89E+02 = AVERAGE TIME (MIN.) FOR A BATCH RELEASE.
- 5. 1.OOE+00 = MINIMUM TINE (MIN.) FOR A BATCH RELEASE.
- 6. 1.84E+06 = AVERAGE DILUTION WATER FLOW DURING RELEASES (GPM).
B. GASEOUS EFFLUENT
- 1. 4.30E+01 = TOTAL NUMBER OF BATCH RELEASES.
- 2. 1. 05E+06 = TOTAL TIME (MIN.) FOR BATCH RELEASES.
- 3. 4.49E+04 = MAXIMUM TIME (MIN.) FOR A BATCH RELEASE.
- 4. 2.44E+04 = AVERAGE TIME (MIN.) FOR A BATCH RELEASE.
- 5. 2.93E+02 = MINIMUM TIME (MIN.) FOR A BATCH RELEASE.
VI. ABNORMAL RELEASES A. LIQUID
- 1. NUMBER OF RELEASES = 0
- 2. TOTAL ACTIVITY RELEASED (CbRIES) = 0 B. GASEOUS
- 1. NUMBER OF RELEASES = 0
- 2. TOTAL ACTIVITY RELEASED (CURIES) = 0
SUPPLEMENTAL REPORT PAGE 2 McGUIRE NUCLEAR STATION The estimated percentage of error for both Liquid and Gaseous effluent release data at McGuire Nuclear Station has been determined to be +/- 25.2%. This value was derived by taking the square root of the sum of the squares of the following discrete individual estimates of error:
(1) Flow rate determining devices = +/- 20%
(2) Counting error - -15%
(3) Sample preparation error = +-3%
McGUIRE NUCLEAR STATION Assessment of Radiation Dose from Radioactive Effluents to Members of the Public (January 1, 2001 through December 31, 2001)
This attachment includes an assessment of radiation doses to the maximum exposed member of the public due to radioactive liquid and gaseous effluents released from the site for each calendar quarter for the calendar year of this report, as well as the total dose for the calendar year. This attachment also includes an assessment of radiation doses to the maximum exposed member of the public from all uranium fuel cycle sources within 10 miles of McGuire for the calendar year of this report to show conformance with 40 CFR 190. Methods for calculating the dose contribution from liquid and gaseous effluents are given in the ODCM.
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 1 't Quarter 2001
== IODINE, H3, AND PARTICULATE DOSE LIMIT ANALYSIS==-== Quarter 1 2001 Critical Critical Dose Limit Max % of Period-Limit Group Organ (mrem) (mrem) Limit Q1 - Maximum Organ Dose CHILD LUNG 1.34E-01 1.50E+01 8.93E-01 Maximum Organ Dose Receptor Location: 0.5 Mile E Critical Pathway: Vegetation Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.00E+02
-= NOBLE GAS DOSE LIMIT ANALYSIS - Quarter 1 2001 Dose Limit % of Period-Limit (mrad) (mrad) Limit Q1 - Maximum Gamma Air Dose 2.19E-02 1.OOE+01 2.19E-01 Maximum Gamma Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.92E+01 Q1 - Maximum Beta Air Dose 8.22E-03 2.OOE+01 4.11E-02 Maximum Beta Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.32E+01
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 2 nd Quarter 2001
-= IODINE, H3, AND PARTICULATE DOSE LIMIT ANALYSIS=== Quarter 2 2001 Critical Critical Dose Limit Max % of Period-Limit Group Organ (mrem) (mrem) Limit Q2 - Maximum Organ Dose CHILD THYROID 1.42E-01 1.50E+01 9.47E-01 Maximum Organ Dose Receptor Location: 0.5 Mile E Critical Pathway: Vegetation Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1. OOE+02
-= NOBLE GAS DOSE LIMIT ANALYSIS Quarter 2 2001 ==
Dose Limit % of Period-Limit (mrad) (mrad) Limit Q2 - Maximum Gamma Air Dose 2.04E-02 1.OOE+01 2.04E-01 Maximum Gamma Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.89E+01 Q2 - Maximum Beta Air Dose 7.65E-03 2.OOE+01 3.83E-02 Maximum Beta Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.31E+01
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 3 rd Quarter 2001
=IODINE, H3, AND PARTICULATE DOSE LIMIT ANALYSIS===--- Quarter 3 2001 Critical Critical Dose Limit Max % of Period-Limit Group Organ (mrem) (mrem) Limit Q3 - Maximum Organ Dose CHILD LIVER 9.23E-02 1.50E+01 6.15E-01 Maximum Organ Dose Receptor Location: 0.5 Mile E Critical Pathway: Vegetation Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.OOE+02
= NOBLE GAS DOSE LIMIT ANALYSISS - - - Quarter 3 2001 -
Dose Limit % of Period-Limit (mrad) (mrad) Limit Q3 - Maximum Gamma Air Dose 2.56E-02 1.0OE+01 2.56E-01 Maximum Gamma Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.94E+01 Q3 - Maximum Beta Air Dose 9.34E-03 2.OOE+01 4.67E-02 Maximum Beta Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.63E+01
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 4t Quarter 2001
IODINE, H3, AND PARTICULATE DOSE LIMIT ANALYSIS= -- Quarter 4 2001 =
Critical Critical Dose Limit Max % of Period-Limit Group Organ (mrem) (mrem) Limit Q4 - Maximum Organ Dose CHILD LIVER 1.75E-01 1.50E+01 1.17E+00 Maximum Organ Dose Receptor Location: 0.5 Mile E Critical Pathway: Vegetation Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1. 00E+02
=== NOBLE GAS DOSE LIMIT ANALYSIS Quarter 4 2001 Dose Limit % of Period-Limit (mrad) (mrad) Limit Q4 - Maximum Gamma Air Dose 2.78E-02 1.00E+01 2_78E-01 Maximum Gamma Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.95E+01 Q4 - Maximum Beta Air Dose 1.01E-02 2.OOE+01 5.05E-02 Maximum Beta Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.68E+01
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 ANNUAL 2001
=IODINE, H3, AND PARTICULATE DOSE LIMIT ANALYSIS==== Annual 2001 Critical Critical Dose Limit Max % of Period-Limit Group Organ (mrem) (mrem) Limit Yr - Maximum Organ Dose CHILD THYROID 5.44E-01 3.OOE+01 1.81E+00 Maximum Organ Dose Receptor Location: 0.5 Mile E Critical Pathway: Vegetation Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.00E+02
-- NOBLE GAS DOSE LIMIT ANALYSIS -- -- Annual 2001 Dose Limit % of Period-Limit (mrad) (mrad) Limit Yr - Maximum Gamma Air Dose 9.58E-02 2.00E+01 4.79E-01 Maximum Gamma Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.93E+01 Yr - Maximum Beta Air Dose 3.53E-02 4.OOE+01 8.83E-02 Maximum Beta Air Dose Receptor Location: 0.5 Mile NNE Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage AR-41 9.50E+01
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 1't Quarter 2001
- BATCH LIQUID RELEASES Quarter 1 2001 ==
Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (orea) Limit Q1 - Maximum Organ Dose CHILD LIVER 3. 73E-02 1.00E+01 3.73E-01 Q1 - Total Body Dose CHILD 2. 83E-02 3.00E+00 9.43E-01 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 7.OOE+01 CS-137 2.88E+01 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 9.24E+01 CS-137 5. 65E+00
== CONTINUOUS LIQUID RELEASES (WC) Quarter 1 2001 Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (orea) Limit Ql - Maximum Organ Dose CHILD LIVER 1.38E-04 1.OOE+01 1.38E-03 Ql - Total Body Dose CHILD 1.38E-04 3.OOE+00 4.60E-03 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or g reater to total)
Nuclide Percentage H-3 1.OOE+02 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or g reater to total)
Nuclide Percentage H-3 1.00OE+02
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 2 nd Quarter 2001
-= BATCH LIQUID RELEASES = Quarter 2 2001 -
Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (trem) Limit Q2 - Maximum Organ Dose CHILD LIVER 1.47E-02 1.OOE+01 1.47E-01 Q2 - Total Body Dose CHILD 1.08E-02 3.OOE+00 3.60E-01 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 5.58E+01 CS-137 3.97E+01 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 5.70E+01 CS-137 3.69E+01
== CONTINUOUS LIQUID RELEASES (WC) Quarter 2 2001 ....
Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (mrem) Limit Q2 - Maximum Organ Dose CHILD LIVER 1.57E-04 1.00E+01 1.57E-03 Q2 - Total Body Dose CHILD 1.57E-04 3.OOE+00 5.23E-03 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1. OOE+02 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.00E+02
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 3 rd Quarter 2001
== BATCH LIQUID RELEASES == Critica Quarter 3 2001 Critical Critical Dose Limit Max % of Age Organ (orem) (mrem) Limit Period-Limit CHILD LIVER 1.66E-02 1.OOE+01 1. 66E-01 Q3 - Maximum Organ Dose Q3 - Total Body Dose CHILD 1.54E-02 3.00E+00 5.13E-01 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 9.13E+01 CS-137 7.91E+00 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 9.81E+01
CONTINUOUS LIQUID RELEASES (WC) =ý Quarter 3 2001
Critical Critical Dose Limit Max % of Age Organ (mrem) (orem) Limit Period-Limit LIVER 7.52E-05 1.OOE+01 7.55E-04 Q3 - Maximum Organ Dose CHILD CHILD 7.52E-05 3.OOE+00 2.51E-03 Q3 - Total Body Dose Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.OOE+02 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.00E+02
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 4t Quarter 2001
== BATCH LIQUID RELEASES = Quarter 4 2001 -
Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (trem) Limit Q4 - Maximum Organ Dose CHILD LIVER 1.68E-02 1.00E+01 1.68E-01 Q4 - Total Body Dose CHILD 1.46E-02 3.OOE+00 4. 87E-01 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 8.39E+01 CS-137 1.50E+01 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 9.69E+01
== CONTINUOUS LIQUID RELEASES (WC) Quarter 4 2001 =-
Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (mrem) Limit Q4 - Maximum Organ Dose CHILD LIVER 1.87E-04 1.OOE+01 1.87E-03 Q4 - Total Body Dose CHILD 1.87E-04 3.OOE+00 6.23E-03 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.OOE+02 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.00E+02
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 LIQUID ANNUAL DOSE
SUMMARY
REPORT McGuire Nuclear Station Units 1 & 2 ANNUAL 2001
= BATCH LIQUID RELEASES Annual 2001 Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (mrem) Limit Yr - Maximum Organ Dose CHILD LIVER 8.11E-02 2.OOE+01 4.06E-01 Yr - Total Body Dose CHILD 6.49E-02 6.OOE+00 1.08E+00 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 7.53E+01 CS-137 2.30E+01 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 9.42E+01
=CONTINUOUS LIQUID RELEASES (WC) Annual 2001 Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem) (mrem) Limit Yr - Maximum Organ Dose CHILD LIVER 5.54E-04 2.OOE+01 2.77E-03 Yr - Total Body Dose CHILD 5.54E-04 6.OOE+00 9.23E-03 Maximum Organ Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.OOE+02 Total Body Critical Pathway: Potable Water Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 1.00OE+02
McGUIRE NUCLEAR STATION 2000 METEOROLOGICAL JOINT FREQUENCY DISTRIBUTIONS OF WIND SPEED, WIND DIRECTION, AND ATMOSPHERIC STABILITY USING WINDS AT THE 10 METER LEVEL (Hours of Occurrence)
s18 19 1t, IT JOT 18 c I VLO I--------------------------- ++ - - -
I 1. I1 IT I 1
+----------------------------I
-II-1 I - -
- - - - - -+ -
- - - - - -+ - -- +- - - -+--
-- - +--
--- -+
-- + . . . . . . . . . . . -. . - .- . -. . -. . - ..-- - - - - - I I IT 1" 1 l. I' 1. IT I I -MN I I--------------------------- ++ - - - +-----------------------------
IT I* +....
- 1.
- IT I. I- I -MSN-I I- ----- + -......- +......--+...-.+-- - ---- +...................------------
IL. 11 1. I1 a IT I I z I. I I --------------------------- -Ms-I
++ - - - +-----------------------------
K
+-
1 IT I* IT -MSS-I I --------------------------- +- -
Kz 1.
+- ------------------------------ I 1 1. it I. I. IT I -Ess-I I------------------- +- - - +------- ----------------------------------
z I. I 1- 1 1. IT IT 1. 1 I -asa-I I------------------- +- - - +----------
+---------------------------I Ia I I-------------------+- - - +---------------------------------------
-a-i I
IL 11 1. 1. IT I: Ic I* I I---------------------------++
-awa-I
- +----------------------------I 13 11 1. Kz 11 H IT 1 1. 1 I------------- +-
-as-1
+--------------------
I I 1.* 11 1. 1 1. 1 -aNs-f I . I I I I II I --------------------------- I I I I I I I I oioasfI I ------- ------- -------
I 'ON I -ON I 'ON I 'N I 'ON I 'ON I -------------------------------------------- 'ON I 'N I 'ON I -I I 'IVaOil s/al1 66-61 66LI 66'S I 66VI 66G5 I 66-Z I 66-1 I I666<1-00o8 1-oo'9 j-oo-s I-oo-- I-oo-s I-ooaZ f-ost I-----I--------------------------------------------I I I ss7DIs U~ S ONIM svqaAaI ?IaMoq'T-Hadn NaaMias L-Vl25a No casvs sassv'to XiiqisyrsS ArIqIEVIS I-Vl'Taa/so11zaUIa/aaadS tINIM NOT t ooa 'SZ Apnraqaa 'Anpuow aSurr OaaA90ox=soad (ToaZ) ADCOrIOHoaIaW 'NIS Hd~arTDON SHILIfDD t
IsST IT Is Is I I I sZ 1T Is IiV IT I I ------- ------- ------- + + --
- +---- ------------------------- I ST It IT 1. 1" 1" 1" IT I" " I" 1 -MN I-------- ------- ------- + + --
- +---- ------------------------- I Is lz IT I' 1* 1* I' I' 1- 1- I* I M I-------- ------- ------- + + --
- +----------------------------- I I- I. I- IT I" I" I" I" Is I. I. I -MM I-------- ------- ------- + + --
- +---- ------------------------- I Iz I1 I I" I I' I" I' IT IT I I -M-I I-------- ------- ------- + + --
- +---- ------------------------- I IT I* I Is IE Is Is Ic Is I* I. I -Ms I-------- ------- ------- + + --
- +---- ------------------------- I ITs I. I. IsE IL IL IT Is IT 1 1* 1 -MS-I I-------- ------- ------- + + --
- +---- ------------------------- I ILT . 1 1 II IsE 18 1 I. 1. K -1ss I---------- - +--------------------------------------------------------------- I Is 1K 11 I' 1. K 1* 1 1 1* 1. 1 -s-I I-------- ------- ------- + + --
- +----------------------------- I Is I. I* I. I. I. IT Is IT K. I. I -ass-I I-- ---- - - - - - -- - - - -- - - - - -- - - - - - -- - - -- - - -+ - --------------
- ------------------- I IT 1 1* 1. IT 1 ' 1* 1* 1. 1* 1 -as-I I-------- ------- ------- + + --
- +---- ------------------------- I I'T, I' 1' 1 K1 IT z 1. I1 1* 1* 1 -asa-I I-------- ------- ------- + + --
- +---- ------------------------- I IsT 1. I' 1* IT 1 Is I I I. 1. 1K 1 -a-I I-------- ------- ------- + + --
- +---- ------------------------- I In K- IT IT I. Is IL ZT z I. I. I -aNa-I I-------- ------- ------- + + --
- +---- ------------------------- I lET K1 K 1. Is I. K Is IT 1' 1' 1 -2N- I I-------- ------- ------- + + --
- +---- ------------------------- I I9 I' 1. 1' IT 11 11 Is Iz 1. 11 1IHN I-------- ------- ------- + + --
- +---- ------------------------- I I8 Is Is IT K* 1- 1K 1* K I* I- I -N-I I I I I I -------
I I I I I I I Iaiasl I----------------------- - +----------+------- ------------------------------- I I 'ON I *ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON II I----- -- - ---- ----------- - +---- -- ----- --- --------
- --- II I "IVzOi I S1 IN 66-6 I 66-L I 66-S I E66-V I 66ES I 66-Z I 66-T I 6tT I 's'r- II 1 66'6<1-00's 1-00'9 I-00'S I-oo'tl I-o'sE I-o'sZ I-oS'T I-ss'T 1-0-oo' 1I I-------------------------------------------------------------- II I I ss'vrq aaaas GNIMII a KlPriiEVI5 'ririflosva ss~aqa UaMOr1-aaddn NaaMIaa I-Variaa NO aasva SaSSVrrz XlrtxsVIS 2lLIrIaISVL L-VrIqaa/NOILDaadIa/aaadS ONIM NOT s sacs 'ss AJanaqea 'Xepuow ZS:yf baŽIaO~x=DOOd (Toes) X5Oo'ouoaiaW 'NIS HVS~IDfN aSlIflDDW T
I[ts I9 IsT I 19t 9 1G I1t9t Its oT Iz I i 0 I----------------------------------------- - +----------------------------- I In Ia I IL I" IT 1 Is9 T I I -MNN*-I I-------- ----------- ------- ---------------- ---- ------------------------- I VET IE IT It, I. az 1 Ia IT I* I* I M _
I ------- ------- ------- + +
-- - +----------------------------- I IT K 1 IT I IT Is I*t" IT IT I -1MM-I I ------- ------- ------- + +
-- - +----------------------------- I OE I* I IT It IT IT I Is IT I I -M-I I-------- ------------------ ---------------- ---- ------------------------- I IEs I. IT Iz Is VET Vz JOE 1K K1 1* I -ms-I I ------- ------- ------- ------------------- - +----------------------------- I las 1. I It' VET 19T Is JOE Ia 1 1. 1 -Ms-I I ------- ------- ------- + +
-- - +----------------------------- I IST' 1 1. 1. Vz I ILt 19T It, 1. K 1 -Mss-I I ----------------------------------- ++ -- - +----------------------------- I 19T 1* 1. I 1 IT Is It I I. I. I -s-I I-------- ----------- ------- --------------- - ---- ------------------------- I lOT K 1. 1 IT I. IT 1s 1. 1 1* I -ESS-I I----------------------+- ------------------------------------------------- I Is 1 1 1. 1. IT Ia It' IT 1 1. 1 -as-I I-------- ----------- ------- ---------------- ---- ------------------------- I ISE 1 1. 1. IT Is 1s I9 It, 1. K 1 -ass-I 18a 1K 1 1. 1 Iz It 19T If: 1. I 1 -s-I I- ----------- ------- ----------- ------- + --------------
I ITTv 1 1. IT K* IE VT JOE Is 1. 1 1 -a~a-I I-------- ---------------------------- - -+- ------------------------------ I ISs 1 1. It' Is ITT Itt 16st It It I* I -sM-I I ------- ------- ------- ------------------- - +----------------------------- I 19C I. IT Is Is s It It It Ic I. I _N _
I---- ------- ------- ------- ---------------- +----------------------------- I ISE IT Is 1ST I. I It Ia lot Is 1 1 -N-I II I I I I I-I-II-I-------------------------I I-------- ----------- ------- --------------- - ---- ------------------------- I I 'N I 'N I 'ON I 'ON I -ON I 'ON I 'ON I -ON I 'ON I 'N I 'ON II I-- -+-- - - - - - -- - - - - -- - - - -- -----------------
- - - - ------- II I -xIVoil s/w I 66-6 I 66-L I 665S I 66-t, 1 66C WI 66t G T I 6tv'T I t,'at II 1 I 66'6<1-00'8 1-oo9 1-00ot 1-oo-T' -0I-oos-oa 1-osT I-saT 10-I- tI I I------------------------------------------------------------- II I I sswD 5[55d5 UNIMII Z ktflISVL5 TIIfl65Vd wrI5Asq H52MOI-H~ddf N55ML5E J.-Vlq5i NO assvs 5555V'iz AJIrtIEYL5 AFI7ISVLS t-vfLaaC/NOIIZ)sa-IC/Oas~ds UMIM NOT aoa ZO sa A:len.qaa 'APpuow a5:Vtt 6a~daZOX=DOaa (tooa) ),0O2OHOSLN MNIS UdVS200N adarnoDw I
Is6t f, I IItTV I a I I st-t ItTt JESET 18sV ott ISE t IE I IVLOL I I---- ----------- ------- ------- +- +-- --------------- +- ---- -------------------------
Issa Ia aZt Ios Ioi' HI' ILE 1GE 1sT S 1s lo9 Ia I -MNN- I I-------- ------- ---- ------- ------- ----------------- - ---- ------------------------- I 186T I' lot lO a aaZ asI Iaa Hav aZt lOT 16 IE IT I -MN-I I-------- ------- ------- ------- --------------------- +- ---- -------------------------
lsst IT I lET sT Iaoscs It ItvT I Is Is I' -
I - - - - - -- - - - - - -- - - - - - -- - - - +-- - -- ++ - - - --
- +----- - - - - - - - - - --------------- I Itoa I- Ia Ist 19T S-E I'i'f Itt' Isa lOT It I9 I1 I -M-1 I - - - - - -- - - - - - -- - - - - - -- - - - +-- - -- ++ - - - --
- +----- - - - - - - - - - --------------- I JEoa I IT I Ia 1T S I9s 196 bOE 19T Is IEc I -MSM I--------------------------- +- -------------------------------------- +-------------- I Iss9 1- 1* isa los Istt sEa lEBt lot Is Is It 1 I -Ms-I I - - - - - -- - - - - - -- - - - - - -- - - - +-- - -- ++ - - - --
- +----- - - - - - - - - - --------------- I Isa I- IK 16 ILa Jott L66 16T I9 It IV IT I -MsS-I I-------- ------- ------- ------- +- + +
-- +- ---- -------------------------
JVst I- 1* t1 s E Htv It Iss isa 1Is IE I I I I -s-I I-------- ------- ------- ------- +- + +
-- +- ---- -------------------------
s9aT I- I. I. I IZ 1 18T JEs IEE 16 IE It I-1T I -aSS-I I - - - - - -- - - - - - -- - - - - - -- - - -+-- - -- ++ - - - --
- +----- - - - - - - - - - --------------- I IsTt I- I I I Is los let H I9 Is IE 1 -Is - I I-------- ------- ------- ------- +- + +
-- - +----------------------------- I Isst I- 1. 1 Iz lET los 1St lET lOT IT I* I. I -s I-------- ------- ------- ------- +- + +
- +----------------------------- I tsaZ I I- I t at Isa19 ITs 196 l6T I-V IT IT I. I -S-I I-------- ------- ------- ------- +- + +
- +----------------------------- I EEI bE I t baIc ITT Isi' H-ot H-tt LEE IL- Ia I-1 1- I -ENS-I I-------- ------- ------- ------- +- + +
+- ---- -------------------------
la'vL IK IT laa log H-vt bEta Iatt lEt' Itt- H Ia IK I -EN-I I-------- ------- ------- ------- +- + +
+- ---- -------------------------
16'vSI- Is 16i' ITt- It6 tat bJaT 19S baa 16 IT IT I -aNN-b I--------------------+- - +- ------- --------------------- - +----------------------------- I losE I- Is ISs lIt- 16i' laS Its los Ita Is IE I. I -N-I I I I I I--I-I--- ------------------------ I I - - -- - - - - - -- - - - - - -- ---------------
- - - - - -- - - - -- ---- + - - - --- - - - - -- - - --------------- - -I I -ON I -ON I 'ON I 'ON I 'ON I 0ON I 'ON I 'ON I -ON I 'ON I 'ON -I ON I-O I rxILO~l S/W 1 66-6 I 66st I 66-9 1 66-V I 66'E I 66'Z I 66-T I EVt I iV'aT I 66'0 I t't'o I I EE6'6<1-00-8 1-00-s 1-00-s 1-0o0i' 1-00-EIs O-1-0 -osT 5 l-Sa-t 1-oo-T I-st-O l-sto II I I-------------------------------------------------------------------------- II I I ssvtZ assas aNimII S'ISAS't U2MOtI-EIddfl NEEMWIS L-VUrISCI NO OSSVS SSSSV'IZ 7UIEIIVIS xLI'iISvLS L-v~iriac/NOILZ3a1ia/cisads ciNIM Not aooa Zs O 'sa ruqeq 'Xepuo)W aS:t't 0ZSaAOX=SOad CtOOa) AD~rO'dOHOSIS *NL'MSUYS'IDON SHIODON T
Fss t I* I. Il I" Is Ioat Is I. Ist It It I -W*VD I------------------ ------- + + --
as IE IT 19 19 JOE IK II I IE Ia I-m _
I---------------------------------------
18T Ist 19 IE ---
IK +----------------------------
II I-I I I----------------------------------------
In,. Kz It
- Is
+ + - - - +---------------------------- I t j1 e s F K - -I a an I lot 19T 16T ILt IL IT It IT I -mNMI I-------- ------- -------
166 IT 1 Ia Iv Ita IsE
+
Ivt
+ -
IL
- - +-------- -------------------- I ITT I"V I -M-1 I---- ------- ------- -------+ + --
--- -------- ---------------------- I tZ6 I- It It 6 Isa Its Ilay It ITT 6 It I -+/-4sM I---- ------- ------- ---------------------
+ + -- --- -------- -------------------
SI I a Iss ITVT 1 IsT Iot 16 IT I -Ms I---- ------- ------- -------+ + --
l6sz I- 1 1. IT Ivt
--- +-------- -------------------- I I---- -------
Isvt Ivy I-vt JETt Is az I_
-------+ + --
16Tt 1 1 " I 1 Is 19 1t I1st loT Is IT I -s-I I------------------- +- - - +--------------------------------------+--------------
Ioat 1- I' I It ItE ITs l6t Is It IT I -ass I------ +--------+- +-- -- - -------+-+-- - +--+------------ -- -- +--------+-----------------I--
ItI. I" IK9 oa IL Is IV I -as-1
-3sa-II I-------- ------- ------- -------+ + -
- - +-------- ---------------------
I9V I1 1* It Isa 16 It Ia a It I I-------- ------- ------- + ---- + --
--- -------- --------------------- -I 1stc I" 1I 19T It Ia IT a I -s-I I----
los KI It
-------+-- -------------- --- +-------- --------------------- I It s Itt ITt Is Ia IV Ia I -SNS I-las I
1*
- -- - - - - - -- - - - - - -- - - - ------------.---- ~- - f---
- - -- - -- - - - - --------------- I 1 I Is Iva ITt It, I IT 11 I -aN-I I------------------- +- - - +--------------------------------------+--------------
Iss 1K 1. 1. I I9 aZt I It It 1 It 1K 1 -aNN-I I---- ------- ------- -------+-- --------------
--- +-------- -------------------- I I-Tt IT IT I* I -N-I I II I I I--I--I-I-------------------------I Is I" I' I* I Io II I I I I -o -s I I-I - --------------- o--------------------
"ON I 'ON I -oN I 'ON I 'ON I 'ON I 'ON I -ON I 'ON I 'ON I 'ON I ON I I--- -- - - - - - -- - - - - - -- - - ----------
- - - -- - - -+- - - --+ ---
-- -+ - -- II I V*OJl 66*6 I 66- I 66s I 661/2 I 66t I 66Z I 66t I W't I V't I 66*0 I tL'o I I0-oos 1-00 I-Ios I-os -00"t I-oo' 1 I-ooa - I-ost 1-sat I-oo't I-stO I-svo I I --------------------------------------------------------------------I II SS 0 Qaaas ONIM S ALIrIsvis lItflOSVd Sr'SAS¶ HSMOr-IHddfl NSERMIS L-VJLr'I NO OaSSY SSS5*V XItqIsvyS A7qlItIanS L-V1'ISa/NOILDasII/oaaaS tNIM Not s ZaoZ 'SZ trenq*aa 'AtpuoW ZS:vt bHSaE OX=DOHE (Ctoo) AOO'OHOSLSW 'NIS ava'iznt SNIOODw t
16s9 It I 19s IsLT I'Lt Iloot IES IZL 18i 1IVIOLI I--------I-------------------------- -- - +-----------------------------I IT 1- 1K 1* 1 1 1* 1* 1 IT I -wrtvzo I I--------------------------------- -- +- ---------------------------- I Is 1.
- 1. IT 1. 11 It1 1tT . IK4 I---------------------------------- + -- - +----------------------------- I I9 I I" I" IL I" I I" I II I -MN-I I--------------- -------------------+ -- - +----------------------------- I 9E K 1 1ITt 9 IL is It z IT I -NMU -I I---------------------------------- + -- - +----------------------------- I ITS 1" I ot JET JOT IL Is I I -M-I I-------- -------------------------- + -- - +----------------------------- I Iss I- I. K Iz I-Vt It 19t JET IsT Itv I -MSM-[
I---------------------------------- + -- - +----------------------------- I Ist I K IT Itv Its 1Z Is6 vit Ir 1T Is I -Ms-I I------------------------------------- - +----------------------------- I K6 1-'1 IV 1st' It't Its It JT 1st is I -Mss--I I-- ------------------------------------------------------------------- I sot I- I I t IsTs81st 1st Is lTOT Iz I -s-1 I-------- ------- -------------------+ -- - +----------------------------- I 16E K* 1. 1 IL Itt It Is Is IT I -299-I I-------- ------- ------- + --
- +---- ------------------------- I In I* I. IT Is Is Is Is It'v Is I -s I-------- ------- ------- + --
- +---- ------------------------- I 1st IT I. IT I. IT I. I' It 1'1 I I-------- -------------- + --
- +----------------------------- I Is I. I. I. I. IT 1K 1. Iz IT I -H-I
------------------- + -- - +----------------------------- I f, 1* 1. 1* Is ItT I ItT I I -EN2S- I
-------------- + --
- +----------------------------- I Itf K
- +---- ------------------------- I It 1. 1 1. T It 1 Is IT Is IT I- N -I I---- ------- ------- ----
-- ------------------------------- I It 1 1* IT 1* It Is IT IT IT I -N-I I I I I I I I I I I I---------------------------- I I I I I I I I I I I I UOIossI I---- -------------- ----
-- ------------------------------- I I -ON I -ON I 'ON I 'ON I -ON I 'N I 'ON I -ON I -ON I 'ON II I-- - - - - -- - - - - - -- -------------
- - - - - -- - - -------- - - - II I 'tViOil 66'L I 66-V I 66-C I &66 I 66-T I 6t'T I tZ'st I 66'0 I t'c-o II 1 1-00-9 1-oo0'- oo1 I- s ostZ I- sstT I- 10't oo I-swo0 I-sro- II I I------------------------------------------------------- II I I SSrID asdSs CONIMII A ALI'IIEYLS 'mnlilsva 9VISASrI 'ISMO¶-USddfl NSSMISS L-YJYISU NO CI59VE 9599\DtD AJtrISYLS 2tLIrEIIvS L-VJ~rISO/NOILDSa~IOI/GadS~ CNIM NOT
'AepuoN Ss:,t 0sa~aOx=soa (toos) ADOqOUOSLSN *NIS UH~S'IIN S~dIOOZN I 9 ZOOs 'SZ Axv-lqaa
oV a-+ .- . .-..
. +-.. . . .--.--
I9 +-.. . . . .-
IE FI I . . . .--+-.. . . . .--
I +-..
I . . . .--
+ . . . . . .-
I I -
- It
- ----- ------- ------- ------- ------------------------------------ I JvT 1. 1K 1K 1 1- K VT I WrIVZ- I I - + - + - + -.......- *------------------+-..................-------------.I Kc ItI F*
IT IF . I It mm -lI I-------------------------- -+- -----------------------------
Iv 1 1 1. IT I II I F - m-I-- ---------------------------------------------------------- I lOT IT Ia I' [a Ia [a IoT I -mm-I I-------------------------+ - - - +----------------------------- I ITt I. I [a IT It Itt IT I -M-1 I------ ------- ------- ------- ------------------------------------ I it 1" 19 1" I, T It' I -MSM-IF---------------------------- - +----------------------------- I I ----------------------------- --- - ------ ---- ----- ------ ---- I iTst IT Is JOa ISa [ot, L tt V JE-MSS-I t
I IF--------------------+-
Z I- z 1IJ - - I FITT IsT L n, JL I
+----------------------------------
lsi' F ITT It' 16o tE -*-S-I I-----------------+- - -------------------------- +------------- I I I" I I" V Fr' Ic I - SS-1 I-------------------------+ - - - +----------------------------- I I I F I. Ft K FzIa IT I -F I-------------------------+ - - - +----------------------------- I It I" Ft IT K" I" IT I -ass-I I-------------------------+ - - - +----------------------------- I It' I* It, F1 F1 11 F1 1- F - I I-------------------------+ - - - +----------------------------- I IT 1 IT 1 F 1- F. 1. F -ENS- 1 I-------------------------- -+- ------------------------------ F Is 1 11 F1 1 Is I -EN-I I -- -- - -- +---........-.-..+.......---......-+-......-+-..-+-.- -_ ------------- I Is I IT IT ' 1 1 IT I -ENN-I I-- +---- ------- ------- ------- ------------------
+-------------- I IT F. I. I F -ti-I I F F I F F F F . .------------------------ FI F F I I I F F *FO s I------ + - --- -- ---------------------
+- + - ------- +----------------------------- F I
I F' I F I -oN I ON I O ON I I F
'ON I-- +---------- ......- +...-- ..- + ......- +-.....------+-- - I I 'n'tIo 6F-E F66o Z I 66'T I 6'rT I r 'T F 6o6 I 'zso I I 1-oos I-ooaZ I-oS't I-sZat I-oo0 T I-s O I-sr'o I I I------------------------------------------- I I FSS.I.
I U3HdTS UNM I o AlI'tiEvS imnosvd SASiAq U2MOq-HSddf N5SM1S2 t-viqsa NO GcSVE ssssrqi ItqIsvas A7IrIEVIS L-YLrISQ/NOILDENIQ/aSSdS ONIM NOt L ZaoZ 'Sa AxenlqaA 'AepuoN aS:tt 6SZa6OX=0Od (tooZ) LDOwOaOiOsw 'NIS EVSqonN 2EnIDNw
l8st'ss Is IL Ios9 los0f 1896 l tLt Itss IlTTt 1s5t Ilot' lots Ittt I IviolI
- - - - -- - - - - - -- - - - - - -- - - -+- - - -- +-- - - - ------------ +- ---- - - - - -- - - - ----------------
ILt I II" I" I" I* I" I" I" II I" I ILt I- vo
+-+---- ------ +-- - +--- -------- +--...... +. ..-.- +......-+......-+......-+......--+-......-+.......------------------. .
IsLt litt IZ los 19'V Ins I1st It9 Its Iss E I I9 It I MNN-i
+ -- - +-------------------- ---
I-------- ------- ------- ------- +- + ---------------
160E lot Is It's Iss 189 ILt Iss 16T let It't 19 It' I -MN-I I - - - - - -- - - - - - -- - - - - - -- - - - +-- - -- +-- - - - ------------ +- ---- - - - - -- - - - ----------------
loos It It' st los Its Is9 IL9 s I Is JET JEt IE I-m I-------- ------- ------- ------- +- + --------------- + -- +- ---- -------------------------
16E I-" IE st 16t 16s loL IL6 Is9 ILt Iss lt Is I -M-I I-------- ------- ------- ------- +- + --------------- + -- - +----------------------------- I IsstL I-' z Iit' Iss Iss I6TT Itts 196 16S Ist'v 16!' Iss I -Ms+/--I
- - - - - -- - - - - - -- - - - +-- - -- +-- - - - ------------ +- ---- - - - - -- - - - --------------- -I I - - - - - --
IessET I ' 1t its les less89 B ICUs IsTT ITS 16S It'9 Iss I -Ms-I I-------- --------- +- - ---- ------- ---- ------- ---- ------- +-------------- --------------- I IToE I- I. IT JET 1Es JOLT Ists Itst 199 1st Jlo Its I -MSS-I I-------- ------- ---- ------- ------- ----------------- - ---- ------------------------- I i't~t' I- I. IT IC Itt Iss boZ IeTT 1Es ISz Isz ITT I -s-I I------------ ------- - ---- ------- ------- ---- ------- ++ --------------
I 19TE I I. I. Isz It Izz I!'VotsEot ISE le3T lt Is 1 -ass-I I - - - - - -- - - - - - -- - - - - - -- - - - +-- - -- +-- - - - ------------ +- ---- - - - - -- - - - ----------------
IESs I- 11 1. IT 16 it'ot l6t't 16"' 1st lOT JET Is I -as-I I-------- ------- ------- ------- +- + --------------- + -- +- ---- -------------------------
less I- 1 1It It' lon 1s 90 so E s16 It't It is i9 1 -asa-I I-------- ------- ------- ------- +- + --------------- + -- - +----------------------------- I l8ess I- I. IT JET ItsE It'ot 1ssT Iss 1s Is I9 It1 1 a-I I-------- ------- ---- ------- ------- ----------------- - ---- ------------------------- I Itst'V I- It' l-tt IsT It's Itst ILtt Its JET It' Is Isz I -aNa-I I--------- - ---- ------- ------- ------- ------- + + --------------
I 19ee 1- IT les 106 Isis l8Es Isss Is9 1sT Is It l Is I EN-1 I-------- ------- ------- ------- +- + --------------- + -- - +----------------------------- I ItSs 1- I9 ISS 1St loot Iot't Isst 1st It's JO lo s J Is I -EaNN-I I-------- ------- ------- ------- +- + --------------- + -- - +----------------------------- I lsst' Is JET Ise Ien Ics In ITe lo8 Iss 16 Is Is I -N-I I II I I I I--I-I--I-------------------------I I-------- ------- ---- ------- ------- ----------------- - ---- ------------------------- I I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I 'ON I -ON I 'ON II I 'IVioiI S/W 1 66'6 1 66't I 66-S I 66't' 1 66'Z I 66-Z I 66'T I 6tt I tZT I 66-0 I t't'O I I S1E66-6<1-00'8 1-00-9 1-00'S 1-oo00 -oo 1-00's I-os't I-ss'r I-oo'100t l-st'o l-st'o I I I--------------------------------------------------------------------------I I I 55VqID OaadS UINIM sassv'n AýlIritalvls ¶Tyi srIaAaqI UaMOrI-Eaddn NSSMLSE LL-VJIaOS NO 025V2 sasswio umflEvis ZiLUISVL5 L-vlqaa/NOlo~aUIa/aaadS ONIM Not
'AVpuow as:t't 0aIAOX=SOId ('roos) AD00OIdOalaW 'NIS aVa"IonN aHinODW T 8 ZOOZ 'ss Lzrniqad
Attachment 2 Solid Waste Disposal Report
REPORT PERIOD McGUIRE NUCLEAR STATION Attachment 1 JANUARY - DECEMBER 2001 SOLID RADIOACTIVE WASTE SHIPPED TO DISPOSAL FACILITIES TYPES OF WASTES SHIPPED Number of Number of Container Disposal Volume Waste Total ft3 m3 Waste from Liquid Systems Shipments Containers Type Class Curies (A) dewatered powdex resin (brokered) none (B) dewatered powdex resin 1 2 STC 418.8 11.86 A/U 3.31 E-05 (C) dewatered bead resin (brokered) none (D) dewatered bead resin none (E) dewatered radwaste system resin none (F) dewatered primary bead resin 7 7 HIC 840 23.79 B 5.54E+02 (G) dewatered mechanical filter media 1 8 HIC 81.6 2.31 C 3.55E+01 (H) dewatered mechanical filter media (brokered) none (I) solidified waste none Dry Solid Waste (A) dry active waste (compacted) none dry active waste (non-compacted) 2 16 HIC 163.2 4.62 A/S 1.27E+01 dry active waste (brokered/compacted) 5 10 STC 373.36 10.57 A/U 1.107E+00 dry active waste (brokered/non-compacted) none (B) sealed sources/smoke detectors none (C) sealed sources none (D) irradiated components none Totals 16 43 1876.96 53.16 6.033E+02 4/18/2002
MCGUIRE NUCLEAR SITE
SUMMARY
OF MAJOR RADIONUCLIDE COMPOSITION I[Type of waste Nuclide % Abundance I 1 Waste from liquid systems:
A. Dewatered Powdex Resin (brokered) None shipped to a disposal facility during this report period.
B. Dewatered Powdex Resin Co-60 87.09 (01-06) Cs-1 37 12.91 C-14 <LLD 1-129 <LLD Tc-99 <LLD H-3 <LLD C. Dewatered Bead Resin (brokered) None shipped to a disposal facility during this report period.
D. Dewatered Bead Resin None shipped to a disposal facility during this report period.
E. Dewatered Radwaste System Resin None shipped to a disposal facility during this report period.
F(1). Dewatered Primary Bead Resin Mn-54 1.50 (01-14) Co-57 0.13 Co-58 0.21 Co-60 18.45 Cs-1 37 2.21 Cs-1 34 0..45 Fe-55 19.06 Ni-63 56.78 H-3 0.22 C-14 0.30 1-129 <LLD Sb-1 25 0.61 Sr-90 0.06 Ce-144 0.0004 Np-237 0.0002 Tc-99 <LLD Pu-238 0.0002 Pu-241 0.02 Am-241 0.0004 Cm-243 0.0003 I
F(2). Dewatered Primary Bead Resin Mn-54 1.60 (01-15) Co-57 0.15 Co-58 0.18 Co-60 18.18 Cs-1 37 2.70 Cs-134 0..54 Fe-55 18.76 Ni-63 56.12 H-3 0.26 C-1 4 0.30 1-129 <LLD Sb-1 22 0.01 Sb-1 25 1.09 Sr-90 0.07 Ce-144 0.0004 Np-237 0.0002 Tc-99 <LLD Pu-238 0.0002 Pu-241 0.02 Am-241 0.0005 Cm-243 0.0003 F(3). Dewatered Primary Bead Resin Mn-54 0.97 (01-19) Co-57 0.23 Co-58 1.22 Co-60 18.30 Cs-137 2.70 Fe-55 18.90 Ni-63 56.41 H-3 0.26 C-14 0.30 1-129 <LLD Sb-125 0.61 Sr-90 0.07 Ce-144 0.0004 Np-237 0.0002 Tc-99 <LLD Pu-238 0.0002 Pu-239 0.0004 Pu-241 0.0233 Am-241 0.0004 Cm-243 0.0003 F(4). Dewatered Primary Bead Resin Mn-54 0.84 (01-24) Co-57 0.23 Co-58 1.34 Co-60 18.30 Cs-137 2.75 Cs- 134 0.16 Fe-55 18.93 Ni-63 56.34 H-3 0.27 C-14 0.30 1-129 <LLD 2
Sb-125 0.45 Sr-90 0.07 Ce-144 0.0004 Np-237 0.0002 Tc-99 <LLD Pu-238 0.0002 Pu-239 0.0004 Pu-241 0.02 Am-241 0.0004 Cm-243 0.0003 Mn-54 1.32 F(5). Dewatered Primary Bead Resin 0.14 (01-26) Co-57 Co-58 0.15 Co-60 18.30 Cs-1 37 2.73 Cs-1 34 0.41 Fe-55 18.91 Ni-63 56.39 H-3 0.27 C-1 4 0.30 1-129 <LLD Sb-1 25 0.99 Sr-90 0.07 Ce-144 0.0004 Np-237 0.0002 Tc-99 <LLD Pu-238 0.0002 Pu-239 0.0004 Pu-241 0.02 Am-241 0.0004 Cm-243 0.0003 Mn-54 0.83 F(6). Dewatered Primary Bead Resin 0.23 (01-27) Co-57 Co-58 1.10 Co-60 18.43 Cs-1 37 2.57 Cs-134 0.12 Fe-55 19.02 Ni-63 56.65 H-3 0.25 C-1 4 0.30 I-129 <LLD Sb-125 0.40 Sr-90 0.07 Ce-144 0.0004 Np-237 0.0002 Tc-99 <LLD Pu-238 0.0002 Pu-239 0.0004 Pu-241 0.0222 Am-241 0.0004 Cm-243 0.0003 3
F(7). Dewatered Primary Bead Resin Mn-54 0.78 (01-28) Co-57 0.20 Co-58 0.72 Co-60 18.38 Cs-1 37 2.97 Cs-1 34 0.21 Fe-55 19.00 Ni-63 56.79 H-3 0.29 C-14 0.30 1-129 <LLD Sb-1 25 0.25 Sr-90 0.08 Ce-144 0.0004 Np-237 0.0003 Tc-99 <LLD Pu-238 0.0002 Pu-239 0.0004 Pu-241 0.0256 Am-241 0.0005 Cm-243 0.0003 G. Dewatered Mechanical Filter Media Mn-54 0.17 (01-03) Co-57 0.00350 Co-60 21.66 Cs-1 37 0.19 Cs-1 34 0.0017 Fe-55 49.36 Ni-63 27.70 H-3 0.01 C-14 0.05 1-129 <LLD Zn-65. 0.0003 Nb-94 0.0107 Sb-125 0.65 Ag-110m 0.0018 Sr-90 0.0073 Ce-144 0.0031 Tc-99 <LLD Pu-238 0.0026 Pu-239 0.0019 Pu-241 0.1563 Am-241 0.0017 Cm-243 0.0037 H. Dewatered Mechanical Filter Media None shipped to a disposal facility (brokered) during this report period.
I. Solidified Waste None shipped to a disposal facility during this report period.
4
- 2. Dry Solid Waste:
A. Dry Active Waste (compacted) Compaction no longer performed on site. No site compacted waste shipped to a disposal facility during this report period.
A(1). Dry Active Waste (non-compacted) Mn-54 0.34 (01-04) Co-58 0.0003 Co-60 12.37 Cs-137 0.21 Fe-55 71.95 Ni-63 12.58 H-3 2.55 C-1 4 <LLD 1-129 <LLD Tc-99 <LLD A(2). Dry Active Waste (non-compacted) Cr-51 3.00 (01-16) Mn-54 1.48 Co-57 0.32 Co-58 53.02 Co-60 8.18 Cs-1 37 0.20 Fe-55 21.54 Fe-59 0.25 Ni-63 10.21 H-3 1.07 C-1 4 <LLD 1-129 <LLD Tc-99 <LLD A(3). Dry Active Waste (brokered / compacted) Mn-54 1.87 (01-01) Co-58 7.18 Co-60 8.42 Cs-1 37 0.10 Fe-55 71.85 Fe-59 0.66 Ni-63 5.80 H-3 1.38 C-14 <LLD 1-129 <LLD Tc-99 <LLD A(4). Dry Active Waste (brokered / compacted) Mn-54 1.52 (01-08) Cr-51 21.91 Co-58 13.27 Co-60 5.60 Cs-137 0.07 Fe-55 49.81 Fe-59 2.26 Ni-63 3.74 H-3 0.98 5
C-14 <LLD 1-129 <LLD Tc-99 <LLD A(5). Dry Active Waste (brokered / compacted) Mn-54 1.68 (01-11) Cr-51 14.63 Co-58 12.39 Co-60 6.45 Cs-137 0.08 Fe-55 56.70 Fe-59 1.86 Ni-63 4.34 H-3 1.03 Zr-95 0.84 C-14 <LLD 1-129 <LLD Tc-99 <LLD A(5). Dry Active Waste (brokered / compacted) Mn-54 1.72 (01-13) Cr-51 12.77 Co-58 11.97 Co-60 6.67 Cs-1 37 0.08 Fe-55 58.71 Fe-59 1.73 Ni-63 4.49 H-3 1.07 Zr-95 0.84 C-14 <LLD 1-129 <LLD Tc-99 <LLD A(5). Dry Active Waste (brokered / compacted) Mn-54 1.47 (01-20) Cr-51 24.70 Co-58 13.47 Co-60 5.32 Cs-1 37 0.06 Fe-55 47.28 Fe-59 2.39 Ni-63 3.55 H-3 0.85 Zr-95 0.94 C-14 <LLD 1-129 <LLD Tc-99 <LLD H. Sealed Sources None shipped to a disposal facility this report period.
I. Sealed Sources/Smoke Detectors None shipped to a disposal facility this report period.
6
J. Irradiated Components None shipped to a disposal facility this report period.
7
Attachment 3 Unplanned Offsite Releases
McGUIRE NUCLEAR STATION UNPLANNED RELEASES (January 1, 2001 through December 31, 2001)
There were no unplanned liquid or gaseous radioactivity releases to the environment in 2001.
Attachment 4 Fuel Cycle Calculation
McGuire Nuclear Station 2001 Radioactive Effluent Releases 40CFR190 Uranium Fuel Cycle Dose* Calculation Results Maximum Total Body Dose = 6.08E-01 mrem Maximum Location: 0.5 Mile, East Sector Critical Age = Child Liquid and Gas Effluent Contribution to Maximum Total Body Dose Liquid Effluent Dose = 6.49E-02 mrem = 11% of total Critical Path = Potable Water Major Contributor = H-3 (94.2%)
Gas Effluent Dose = 5.44E-01 mrem = 89% of total Critical Path = Vegetation Major Contributor = H-3 (100.0%)
Maximum Organ Dose = 6.25E-01 mrem Maximum Location: 0.5 Mile, East Sector Critical Age = Child Critical Organ = Liver Liquid and Gas Effluent Contribution to Maximum Organ Dose Liquid Effluent Dose = 8.11E-02 mrem = 13% of total Critical Path = Potable Water Major Contributors = H-3 (75.3%)
CS-137 (23.0%)
Gas Effluent Dose = 5.44E-01 mrem = 87% of total Critical Path = Vegetation Major Contributor = H-3 (100.0%)
- Annual dose limits from 40CFR190.10(a) of 25 mrem whole body, 75 mrem to the thyroid, and 25 mrem to any other organ.
Attachment 5 Inoperable Monitoring Equipment
McGuire Nuclear Station Inoperable Monitoring Equipment (January 1, 2001 through December 31, 2001)
There were no SLC related effluent monitoring instruments out of service greater than the SLC limits for operability.
Attachment 6 UFSAR Section 16.11
Liquid Effluents - Concentration 16.11.1 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.1 Liquid Effluents - Concentration COMMITMENT The concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS (see Figure 16.11.1-1) shall be limited:
- a. For radionuclides other than dissolved or entrained noble gases, 10 times the effluent concentrations specified in 10 CFR Part 20, Appendix B, Table 2, Column 2, and
- b. For dissolved or entrained noble gases, the concentration shall be limited to 2 x 10-4 microCurie/ml total activity.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Concentration of A.1 Restore the concentration Immediately radioactive material to within limits.
released in liquid effluents to UNRESTRICTED AREAS not within limits.
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.1.1 ------------------- NOTE- ----------------
The results of the radioactivity analyses shall be used in accordance with the methodology and parameters in the ODCM to assure that the concentrations at the point of release are maintained within the limits.
Sample and analyze radioactive liquid wastes according According to to Table 16.11.1-1. Table 16.11.1-1 McGuire Units 1 and 2 16.11.1-1 Revision 9
Liquid Effluents - Concentration 16.11.1 TABLE 16.11.1-1 (Page 1 of 3)
RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM LIQUID RELEASE SAMPLING MINIMUM TYPE OF LOWER LIMIT TYPE FREQUENCY ANALYSIS ACTIVITY OF DETECTION FREQUENCY ANALYSIS (LLD) microCi/ml (1)
- 1. Batch Waste P P Principal 7 Release Tanks Each Batch Each Batch Gamma 5x10 (WMT and Emitters(6 )
RMT) (41 1-131 1x10-6 P M Dissolved and One Batch/M Entrained lxl0s Gases (Gamma emitters)(7)
P M H-3 1 xi 0-s Each Batch Composite(2)
Gross Alpha 1x10. 7 P Q Sr-89, Sr-90 5x10 Each Batch Composite(2)
- 2. Continuous Continuous(3) W Principal Releases Composite{3 ) Gamma 5xl 0 (VUCDT Emitters (6) discharge, CWWTS outlet and Turbine Building Sump to RC)(5) 1-131 1x10-6 M M Dissolved and Grab Sample Entrained 1x1 0-5 Gases (Gamma emitters)(7 )
Continuous(3) M H-3 1xi 0-5 Composite (3)
Gross Alpha 1x1 0-7 Continuous(3) Q Sr-89, Sr-90 5x10 8 Composite(3)
McGuire Units 1 and 2 16.11.1-2 Revision P
Liquid Effluents - Concentration 16.11.1 TABLE 16.11.1-1 (Page 2 of 3)
NOTES:
(1) The LLD is defined, for purposes of these commitments, as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system (which may include radiochemical separation):
LLD = 4.66 sb E V - 2.22 x 106
- Y exp (-2At)
Where:
LLD is the "a priori" lower limit of detection as defined above (as microCurie per unit mass or volume),
Sb is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute),
E is the counting efficiency (as counts per disintegration),
V is the sample size (in units of mass or volume),
2.22 x 106 is the number of disintegrations per minute per microCurie, Y is the fractional radiochemical yield (when applicable),
X is the radioactive decay constant for the particular radionuclide, and At is the elapsed time between midpoint of sample collection and time of counting (for plant effluents, not environmental samples).
Typical values of E, V, Y and At shall be used in the calculation.
It should be recognized that the LLD is defined as an a Driori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.
(2) A composite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged and in which the method of sampling employed results in a specimen which is representative of the liquids released.
McGuire Units 1 and 2 16.11.1-3 Revision 9
Liquid Effluents - Concentration 16.11.1 TABLE 16.11.1-1 (Page 3 of 3)
(3) To be representative of the quantities and concentrations of radioactive materials in liquid effluents, samples shall be collected continuously or intermittently in proportion to the rate of flow of the effluent stream. Prior to analyses, all samples taken for the composite shall be thoroughly mixed in order for the composite sample to be representative of the effluent release.
(4) A batch release is the discharge of liquid wastes of a discrete volume. Prior to sampling for analyses, each batch shall be isolated and thoroughly mixed to assure representative sampling.
(5) A continuous release is the discharge of liquid wastes of a nondiscrete volume; e.g.,
from a volume of system that has an input flow during the continuous release.
(6) The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, and Ce-141. The LLD for Ce-144 is 5x1 06 microCi/ml. This list does not mean that only these nuclides are to be detected and reported. Other peaks which are measurable and identifiable, together with the above nuclides, shall be identified and reported in the Annual Radioactive Effluent Release Report.
(7) The principal gas gamma emitters for which the LLD specification applies are Xe-133 and Xe-1 35. These are the reference nuclides in Regulatory Guide 1.21.
McGuire Units 1 and 2 16.11.1-4 Revision 9
Liquid Effluents - Concentration 16.11.1 FIGURE 16.11.1-1 SITE BOUNDARY McGuire Units 1 and 2 16.11.1-5 Revision 9
Liquid Effluents - Concentration 16.11.1 BASES This commitment is provided to ensure that the concentration of radioactive materials released in liquid waste effluents to UNRESTRICTED AREAS will be less than 10 times the effluent concentration levels specified in 10 CFR Part 20, Appendix B, Table 2, Column 2.
This limitation provides additional assurance that the levels of radioactive materials in bodies of water in UNRESTRICTED AREAS will result in exposures within: (1) the Section II.A design objectives of Appendix 1, 10 CFR Part 50, to a MEMBER OF THE PUBLIC, and (2) the limits of 10 CFR Part 20.1301 to the population. The concentration limit for dissolved or entrained noble gases is based upon the assumption that Xe-135 is the controlling radioisotope and its EC in air (submersion) was converted to an equivalent concentration in water using the methods described in International Commission on Radiological Protection (ICRP) Publication 2. This commitment applies to the release of liquid effluents from all reactors at the site.
The basic requirements for the Selected Licensee Commitments concerning effluents from nuclear power reactors are stated in 1 OCFR50.36a. These requirements indicate that compliance with effluent Selected Licensee Commitments will keep average annual releases of radioactive material in effluents to small percentages of the limits specified in the old 10CFR20.106 (new 10CFR20.1301). These requirements further indicate that operational flexibility is allowed, compatible with considerations of health and safety, which may temporarily result in releases higher than such small percentages, but still within the limits specified in the old 10CFR20.106 which references Appendix B, Table II concentrations (MPCs). These referenced concentrations are specific values which relate to an annual dose of 500 mrem. It is further indicated in 10CFR50.36a that when using operational flexibility, best efforts shall be exerted to keep levels of radioactive materials in effluents as low as is reasonably achievable (ALARA) as set forth in 10CFR50, Appendix I.
As stated in the Introduction to Appendix B of the new 1 OCFR20, the effluent concentration (EC) limits given in Appendix B, Table 2, Column 2, are based on an annual dose of 50 mrem. Since a release concentration corresponding to a limiting dose rate of 500 mrem/year has been acceptable as a SLC limit for liquid effluents, which applies at all times as an assurance that the limits of 10CFR50, Appendix I are not likely to be exceeded, it should not be necessary to reduce this limit by a factor of 10.
Operational history at Catawba/McGuire/Oconee has demonstrated that the use of the concentration values associated with the old 10CFR20.106 as SLC limits has resulted in calculated maximum individual doses to members of the public that are small percentages of the limits of 10CFR50, Appendix I. Therefore, the use of concentration values which correspond to an annual dose of 500 mrem should not have a negative impact on the ability to continue to operate within the limits of 10CFR50 Appendix I and 40CFR1 90.
Having sufficient operational flexibility is especially important in establishing a basis for effluent monitor setpoint calculations. As discussed above, the concentrations stated in the new 10CFR20, Appendix B, Table 2, Column 2, relate to a dose of 50 mrem in a year.
When applied on an instantaneous basis, this corresponds to a dose rate of 50 mrem/year.
This low value is impractical upon which to base effluent monitor setpoint calculations for many liquid effluent release situations when monitor background, monitor sensitivity, and monitor performance must be taken into account.
BASES (continued)
McGuire Units 1 and 2 16.11.1-6 Revision 9
Liquid Effluents - Concentration 16.11.1 Therefore, to accommodate operational flexibility needed for effluent releases, the limits associated with SLC 16.11.1 are based on ten times the concentrations stated in the new 10CFR20, Appendix B, Table 2, Column 2 to apply at all times. The multiplier of ten is proposed because the annual dose of 500 mrem, upon which the concentrations in the old 10CFR20, Appendix B, Table II, Column 2 are based, is a factor of ten higher than the annual dose of 50 mrem, upon which the concentrations in the new 10CFR20, Appendix B, Table 2, Column 2, are based. Compliance with the limits of the new 10CFR20.1301 will be demonstrated by operating within the limits of 10CFR50, Appendix I and 40CFR1 90.
The required detection capabilities for radioactive materials in liquid waste samples are tabulated in terms of the lower limits of detection (LLDs). Detailed discussion of the LLD, and other detection limits can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, L. A., "Limits for Qualitative Detection and Quantitative Determination Application to Radiochemistry," Anal. Chem. 40, 586-93 (1968), and Hartwell, J. K.,
"Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).
REFERENCES
- 1. McGuire Nuclear Station Offsite Dose Calculation Manual (ODCM)
- 2. International Commission on Radiological Protection (ICRP) Publication 2 McGuire Units 1 and 2 16.11.1 -7 Revision 9
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.2 Radioactive Liquid Effluent Monitoring Instrumentation COMMITMENT The radioactive liquid effluent monitoring instrumentation channels shown in Table 16.11.2-1 shall be OPERABLE with their Alarm/Trip Setpoints set to ensure that the limits of SLC 16.11.1 are not exceeded.
AND The Alarm/Trip Setpoints of these channels shall be determined and adjusted in accordance with the methodology and parameters in the OFFSITE DOSE CALCULATION MANUAL (ODCM).
APPLICABILITY At all times.
REMEDIAL ACTIONS
NOTE ----------------------------------------------------
Separate Condition entry is allowed for each Function.
CONDITION REQUIRED ACTION COMPLETION TIME A. One or more radioactive A.1 Suspend the release of Immediately liquid effluent monitoring radioactive liquid effluents channels Alarm/Trip monitored by the affected setpoint less channel.
conservative than required. OR A.2 Declare the channel Immediately inoperable.
OR A.3 Adjust setpoint to within Immediately limit.
B. One or more radioactive B.1 Enter the Remedial Action Immediately liquid effluent monitoring specified in Table 16.11.2 instrument channels 1 for the channel(s).
(continued)
McGuire Units 1 and 2 16.11.2-1 Revision 23
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 REMEDIAL ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C. One channel inoperable. I C.1.1 Analyze two independent Prior to initiating a samples per TR 16.11.1.1. release AND C.1.2 Perform independent Prior to initiating a verification of the discharge release line valving.
AND C.1.3.1 Perform independent Prior to initiating a verification of manual release portion of the computer input for the release rate calculations performed by computer.
OR C.1.3.2Perform independent Prior to initiating a verification of entire release release rate calculations for calculations performed manually.
AND C.1.4 Restore channel to 14 days OPERABLE status.
OR C.2 Suspend the release of Immediately radioactive effluents via this pathway.
(continued)
McGuire Units 1 and 2 16.11.2-2 Revision 23
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 REMEDIAL ACTIONS (continued CONDITION REQUIRED ACTION COMPLETION TIME D. One channel inoperable. D.1 Perform an analysis of grab Once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> samples for radioactivity at during releases a lower limit of detection when secondary per Table 16.11.1-1. specific activity is
> 0.01 pCi/gm DOSE EQUIVALENT 1-131 AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> during releases when secondary specific activity is
<:0.01 gCi/gm DOSE EQUIVALENT 1-131 AND D.2 Restore the channel to 30 days OPERABLE status.
E. One or more channels E.1 Perform an analysis of grab Once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> inoperable, samples for radioactivity at during releases a lower limit of detection per Table 16.11.1-1.
AND E.2 Restore the channel to 30 days OPERABLE status.
(continued)
McGuire Units 1 and 2 16.11.2-3 Revision 23
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 REMEDIAL ACTIONS (continued CONDITION REQUIRED ACTION COMPLETION TIME F. One or more flow rate F.1 ---------- NOTE -------
measurement channels Pump performance curves inoperable, generated in place may be used to estimate flow.
Estimate the flow rate of Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> the release. during releases AND F.2 Restore the channel to 30 days OPERABLE status.
G. RC minimum flow G.1 Verify that the number of Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> interlock inoperable, pumps providing dilution is during releases greater than or equal to the number of pumps required.
AND G.2 Restore the channel to 30 days OPERABLE status.
H. Required Action and H.1 Explain why the In the next associated Completion inoperability was not scheduled Annual Time of Condition C, D, corrected within the Radioactive Effluent E, F, or G not met. specified Completion Time Release Report in the Annual Radioactive Effluent Release Report.
McGuire Units 1 and 2 16.11.2-4 Revision 23
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 TESTING REQUIREMENTS
. NOTE ------------------------------------------------------
Refer to Table 16.11.2-1 to determine which TRs apply for each Radioactive Liquid Effluent Monitoring channel.
TEST FREQUENCY TR 16.11.2.1 Perform CHANNEL CHECK. 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> TR 16.11.2.2 ----------- NOTE ----------------------------------
The CHANNEL CHECK shall consist of verifying indication of flow.
Perform CHANNEL CHECK. Every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> during periods of release TR 16.11.2.3 Perform SOURCE CHECK. Prior to each release TR 16.11.2.4 Perform SOURCE CHECK. 31 days TR 16.11.2.5 ----------- NOTES -------------------------------
- 1. For Instrument 1, the COT shall also demonstrate that automatic isolation of the pathway occurs if the instrument indicates measured levels above the Alarm/Trip Setpoint.
- 2. For Instruments 1 and 2, the COT shall also demonstrate that control room alarm annunciation occurs if the instrument indicates measured levels above the Alarm/Trip Setpoint; circuit failure and, a downscale failure.
Perform CHANNEL OPERATIONAL TEST. 92 days TR 16.11.2.6 Perform a CHANNEL CALIBRATION. 18 months (continued)
McGuire Units 1 and 2 16.11.2-5 Revision 23
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 TESTING REQUIREMENTS (continued)
TEST FREQUENCY TR 16.11.2.7 ---------------- NOTE -------------------------------------
The initial CHANNEL CALIBRATION shall be performed using standards certified by the National Institute of Standards and Technology (NIST) or using standards obtained from suppliers that participate in measurement assurance activities with NIST. These standards shall permit calibrating the system over its intended range of energy and measurement range. For subsequent CHANNEL CALIBRATION, sources that have been related to the initial calibration shall be used.
Perform a CHANNEL CALIBRATION. 24 months McGuire Units 1 and 2 16.11.2-6 Revision 23
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 TABLE 16.11.2-1 RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION INSTRUMENT MINIMUM REMEDIAL TESTING CHANNELS ACTION REQUIREMENTS OPERABLE
- 1. Radioactivity Monitors Providing Alarm And Automatic Termination of Release
- a. Waste Liquid Effluent Line (EMF-49) 1 per station A, C, H TR 16.11.2.1 TR 16.11.2.3 TR 16.11.2.5 TR 16.11.2.7
- c. Containment Ventilation Unit Condensate Line 1 A, E, H TR 16.11.2.1 (EMF-44) TR 16.11.2.4 TR 16.11.2.5 TR 16.11.2.7
- 2. Radioactivity Monitors Providing Alarm But Not Automatic Termination of Release
- a. Conventional Waste Water Treatment Line 1 A, D, H TR 16.11.2.1 or Turbine Building Sump to RC (EMF-31) TR 16.11.2.4 TR 16.11.2.5 TR 16.11.2.7 1 D, H TR 16.11.2.5
- b. EMF-31 Minimum Flow Device TR 16.11.2.7
- 3. Continuous Composite Samplers
- b. Conventional Waste Water Treatment Line 1 per station E, H TR 16.11.2.2 TR 16.11.2.5 TR 16.11.2.6
McGuire Units 1 and 2 16.11.2-7 Revision 23
Radioactive Liquid Effluent Monitoring Instrumentation 16.11.2 I~ I I
- 4. Flow Rate Measurement Devices 1 per station F, H TR 16.11.2.2
- b. Containment Ventilation Unit Condensate Line 1 TR 16.11.2.5 TR 16.11.2.6 1 per station F, H TR 16.11.2.2
- 5. RC Minimum Flow Interlock (1) 1 per station G, H TR 16.11.2.5 NOTES:
- 1. Minimum flow dilution is assured by an interlock which terminates waste liquid release ifthe number of RC pumps running falls below the number of pumps required for dilution. The required number of RC pumps for dilution is determined per station procedures.
BASES The radioactive liquid effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in liquid effluents during actual or potential releases of liquid effluents. The Alarm/Trip Setpoints of these instruments shall be calculated and adjusted in accordance with the methodology and parameters in the ODCM to ensure that the Alarm/Trip will occur prior to exceeding the limits stated in SLC 16.11.1.
The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50. The Turbine Building Sump to RC Discharge Flow Measurement and Sampler Devices are for monitoring only and do not alarm or have any controls that require a quarterly COT.
REFERENCES
- 1. McGuire Nuclear Station Offsite Dose Calculation Manual (ODCM)
- 2. 10 CFR Part 50, Appendix A McGuire Units 1 and 2 16.11.2-8 Revision 23
Dose - Liquid Effluents 16.11.3 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.3 Dose - Liquid Effluents COMMITMENT The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released from each unit to UNRESTRICTED AREAS (see Figurel6.11.1-1) shall be limited:
- a. During any calendar quarter, to < 1.5 mrem to the total body and to < 5 mrem to any organ, and
- b. During any calendar year, to < 3 mrem to the total body and to
< 10 mrem to any organ.
APPLICABILITY At all times.
REMEDIAL ACTIONS
-------NO T E S OTES.................................... -----------
Enter applicable Conditions and Required Actions of SLC 16.11.12, "Total Dose," when the limits of this SLC are exceeded by twice the specified limit.
CONDITION REQUIRED ACTION COMPLETION TIME A. Calculated dose from -------- NOTE -------------
release of radioactive The Special Report shall include materials in liquid the results of radiological analyses effluents exceeding of the drinking water source, and above limits, the radiological impact on finished drinking water supplies with regard to the requirements of 40 CFR 141, Safe Drinking Water Act, as applicable.
A.1 Prepare and submit a 30 days Special Report to the NRC which identifies the causes for exceeding the limits, corrective actions taken to reduce releases, and actions taken to ensure that subsequent releases are within limits.
McGuire Units 1 and 2 16.11.3-1 Revision 0
Dose - Liquid Effluents 16.11.3 TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.3.1 Determine cumulative dose contributions from liquid 31 days effluents for current calendar quarter and current calendar year in accordance with the methodology and parameters in the ODCM.
BASES This commitment is provided to implement the requirements of Sections II.A, lII.A and IV.A of Appendix 1, 10 CFR Part 50. The commitment implements the guides set forth in Section II.A of Appendix I. The REMEDIAL ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable." Also, for fresh water sites with drinking water supplies that can be potentially affected by plant operations, there is reasonable assurance that the operation of the facility will not result in radionuclide concentrations in the finished drinking water that are in excess of the requirements of 40 CFR Part 141. These requirements are applicable only if the drinking water supply is taken from the river 3 miles downstream of the plant discharge.
The dose calculation methodology and parameters in the ODCM implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. The equations specified in the ODCM for calculating the doses due to the actual release rates of radioactive materials in liquid effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.113, "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," April 1977.
This commitment applies to the release of liquid effluents from each unit at the site. For units with shared Radwaste Treatment Systems, the liquid effluents from the shared system are to be proportioned among the units sharing that system in accordance with the guidance given in NUREG-01 33, Chapter 3.1.
McGuire Units 1 and 2 16.11.3-2 Revision 0
Dose - Liquid Effluents 16.
11.3 REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 2. 40 CFR Part 141, Safe Drinking Water Act
- 4. Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977.
- 5. Regulatory Guide 1.113, "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," April 1977.
McGuire Units 1 and 2 16.11.3-3 Revision 0
Liquid Radwaste Treatment System 16.11.4 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.4 Liquid Radwaste Treatment System COMMITMENT The Liquid Radwaste Treatment System shall be OPERABLE and appropriate portions of the system shall be used to reduce releases of radioactivity when the projected doses due to the liquid effluent from each unit to UNRESTRICTED AREAS (see Figurel 6.11.1 -1) would exceed 0.06 mrem to the total body or 0.2 mrem to any organ in a 31 day period.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Radioactive liquid waste A.1 Prepare and submit a 30 days being discharged without Special Report to the NRC treatment and in excess which identifies the reasons of above limits, liquid radwaste was discharged without AND treatment, identification of inoperable equipment and Any portion of Liquid reasons for inoperability, Radwaste Treatment corrective actions taken to System not in operation. restore the equipment to OPERABLE status, and actions taken to prevent recurrence.
McGuire Units 1 and 2 16.11.4-1 Revision 0
Liquid Radwaste Treatment System 16.11.4 TESTING REQUIREMENTS The Liquid Radwaste Treatment System shall be demonstrated OPERABLE by meeting SLC 16.11.1 andl6.11.3.
TEST FREQUENCY TR 16.11.4.1 Project liquid release doses from each unit to 31 days UNRESTRICTED AREAS, in accordance with the methodology and parameters in the ODCM, when water systems are being released without being processed by its radwaste treatment system.
BASES The requirement that the appropriate portions of this system be used, when specified, provides assurance that the releases of radioactive materials in liquid effluents will be kept "as low as is reasonably achievable". This specification implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50 and the design objective given in Section II.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the Liquid Radwaste Treatment System were specified as a suitable fraction of the dose design objectives set forth in Section II.A of Appendix 1,10 CFR Part 50, for liquid effluents.
This commitment applies to the release of liquid effluents from each reactor at the site. For units with shared Radwaste Treatment Systems, the liquid effluents from the shared system are to be proportioned among the units sharing that system in accordance with the guidance given in NUREG-01 33, Chapter 3.1.
REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 2. 10CFRPart50
- 3. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.4-2 Revision 0
Chemical Treatment Ponds 16.11.5 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.5 Chemical Treatment Ponds COMMITMENT The quantity of radioactive material contained in each chemical treatment pond shall be limited by the following expression (excluding tritium and dissolved or entrained noble gases):
264 Y A1 <1.0 V j (Cj x 10)
Where:
A j = pond inventory limit for single radionuclide "j", in Curies C = 10 CFR 20, Appendix B, Table 2, Column 2, concentration for single radionuclide "j", microCuries/ml; V = design volume of liquid and slurry in the pond, in gallons; and 264 = conversion unit, microCuries/Curie per milliliter/gallon.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Quantity of radioactive A.1 Suspend all additions of Immediately material in any of the radioactive material to the chemical treatment pond.
ponds exceeding above limit. AND A.2 Initiate corrective action to Immediately reduce the pond contents to within limits.
McGuire Units 1 and 2 16.11.5-1 Revision 0
Chemical Treatment Ponds 16.11.5 TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.5.1 Verify quantity of radioactive material in each batch of Prior to each slurry (powdex resin) to be transferred to chemical transfer treatment ponds is within limits by analyzing a representative sample of the slurry. Each batch to be transferred to the chemical treatment ponds is limited by:
SQ Q <6.0x 105 pCi/gm I (C i x 10) ,lCi/rnl BASES The inventory limits of the chemical treatment ponds (CTP) are based on limiting the consequences of an uncontrolled release of the pond inventory. The expression in SLC 16.11.5 assumes the pond inventory is uniformly mixed, that the pond is located in an uncontrolled area as defined in 10 CFR Part 20, and that the concentration limit in Note 4 to Appendix B of 10 CFR Part 20 applies.
The batch limits of slurry to the chemical treatment ponds assure that radioactive material in the slurry transferred to the CTP are "as low as is reasonably achievable" in accordance with 10 CFR Part 50.36a. The expression in SLC 16.11.5 assures no batch of slurry will be transferred to the CTP unless the sum-of the ratios of the activity of the radionuclides to their respective concentration limitation is less than the ratio of the 10 CFR Part 50, Appendix I, Section II.A, total body dose level to the instantaneous whole body dose rate limitation, or that:
Z c C.
3 mreml/yr_
3= 0.006 j (C 1 xlO) 500 mrem/yr Where:
- c. = Radioactive slurry concentration for radionuclide "j" entering the UNRESTRICTED AREA chemical treatment ponds, in microCuries/milliliter; and Cj = 10 CFR 20, Appendix B, Table 2, Column 2, concentration for single radionuclide "j", in microCuries/milliliter.
McGuire Units 1 and 2 16.11.5-2 Revision 0
Chemical Treatment Ponds 16.11.5 BASES (continued)
For the design of filter/demineralizers using powder resin, the slurry wash volume and the weight of resin used per batch is fixed by the cell surface area, and the slurry volume to resin weight ratio is constant at 100 ml/gram of wet, drained resin with a moisture content of approximately 55 to 60% (bulk density of about 58 pounds per cubic feet). Therefore, Y _ =-_ QJ < 0.006, and j (C j x 10) j (C i x 10) (102 mI/gm) (106 pCi/lCi)
Z Q < 6.0 X 10 5 PCi/gM S(C 1 x 10) UcCi/mi Where:
Qj = concentration of radioactive materials in wet, drained slurry (powdex resin) for radionuclide "j", excluding tritium, dissolved or entrained noble gases, and radionuclides with less than an 8-day half-life. The analysis shall include at least Ce-144, Cs-134, Cs 137, Co-58 and Co-60, in picoCuries/gram. Estimates of the Sr-89 and Sr-90 batch concentration shall be included based on the most recent monthly composite analysis (within 3 months); and C1 = 10 CFR 20, Appendix B, Table 2, Column 2, concentration for single radionuclide "j", in microCuries/milliliter.
The batch limits provide assurance that activity input to the chemical treatment ponds will be minimized, and a means of identifying radioactive material in the inventory limitation of SLC 16.11.5.
The basic requirements for the Selected Licensee Commitments concerning effluents from nuclear power reactors are stated in 10CFR50.36a. These requirements indicate that compliance with effluent Selected Licensee Commitments will keep average annual releases of radioactive material in effluents to small percentages of the limits specified in the old 10CFR20.106 (new 10CFR20.1301). These requirements further indicate that operational flexibility is allowed, compatible with considerations of health and safety, which may temporarily result in releases higher than such small percentages, but still within the limits specified in the old 10CFR20.106 which references Appendix B, Table II concentrations- (MPCs). These referenced concentrations are specific values which relate to an annual dose of 500 mrem. It is further indicated in 10CFR50.36a that when using operational flexibility, best efforts shall be exerted to keep levels of radioactive materials in effluents as low as is reasonably achievable (ALARA) as set forth in 10CFR50, Appendix I.
McGuire Units 1 and 2 16.11.5-3 Revision 0
Chemical Treatment Ponds 16.11.5 BASES (continued)
As stated in the Introduction to Appendix B of the new 10CFR20, the effluent concentration (EC) limits given in Appendix B, Table 2, Column 2, are based on an annual dose of 50 mrem. Since a release concentration corresponding to a limiting dose rate of 500 mrem/year has been acceptable as a SLC limit for liquid effluents, which applies at all times as an assurance that the limits of 10CFR50, Appendix I are not likely to be exceeded, it should not be necessary to reduce this limit by a factor of 10.
Operational history at Catawba/McGuire/Oconee has demonstrated that the use of the concentration values associated with the old 10CFR20.106 as SLC limits has resulted in calculated maximum individual doses to members of the public that are small percentages of the limits of 10CFR50, Appendix I. Therefore, the use of concentration values which correspond to an annual dose of 500 mrem should not have a negative impact on the ability to continue to operate within the limits of 10CFR50, Appendix I and 40CFR1 90.
Having sufficient operational flexibility is especially important in establishing a basis for effluent monitor setpoint calculations. As discussed above, the concentrations stated in the new 10CFR20, Appendix B, Table 2, Column 2, relate to a dose of 50 mrem in a year.
When applied on an instantaneous basis, this corresponds to a dose rate of 50 mrem/year.
This low value is impractical upon which to base effluent monitor setpoint calculations for many liquid effluent release situations when monitor background, monitor sensitivity, and monitor performance must be taken into account.
Therefore, to accommodate operational flexibility needed for effluent releases, the limits associated with SLC 16.11.1 are based on ten times the concentrations stated in the new 10CFR20, Appendix B, Table 2, Column 2 to apply at all times. The multiplier of ten is proposed because the annual dose of 500 mrem, upon which the concentrations in the old 10CFR20, Appendix B, Table II, Column 2 are based, is a factor of ten higher than the annual dose of 50 mrem, upon which the concentrations in the new 10CFR20, Appendix B, Table 2, Column 2, are based. Compliance with the limits of the new 10CFR20.1301 will be demonstrated by operating within the limits of 1 OCFR50, Appendix I and 40CFR1 90.
REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 3. 10 CFR 50, Appendix I, Section IL.A
- 4. 10CFR20
- 5. 10CFR50.36a McGuire Units 1 and 2 16.11.5-4 Revision 0
Dose Rate - Gaseous Effluents 16.11.6 16.11 RADIOLOGICAL EFFLUENT CONTROL 16.11.6 Dose Rate - Gaseous Effluents COMMITMENT The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY (see Figurel6.11.1-1) shall be limited to the following:
- a. For noble gases: < 500 mrem/yr to the whole body and < 3000 mrem/yr to the skin, and
- b. For Iodine - 131 and 133, for tritium, and for all radioactive materials in particulate form with half-lives greater than 8 days:
< 1500 mrem/yr to any organ.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Dose rate not within A.1 Restore the release rate to Immediately limit, within limits.
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.6.1 Verify dose rates due to noble gases in gaseous effluents In accordance with are within limits in accordance with the methodology and the ODCM parameters in the ODCM.
TR 16.11.6.2 Verify dose rates due to radioactive materials, other than In accordance with noble gases, in gaseous effluents are within limits in Table 16.11.6-1 accordance with the methodology and parameters in the ODCM by obtaining representative samples and performing analyses in accordance with Tablel6.11.6-1.
McGuire Units 1 and 2 16.11.6-1 Revision 0
Dose Rate - Gaseous Effluents 16.11.6 TABLE 16.11.6-1 (Page 1 of 4)
RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Gaseous Release Type Sampling Frequency Minimum Analysis Type of Activity Analysis Lower Limit of Frequency Detection (LLD)(')
(RCi/ml)
- 1. Waste Gas Storage Tanks P P 4 Each Tank Each Tank Principal Gas Gamma Emitters(6 ) 1x10 Grab Sample
- 2. Containment Purge P P 4 6
Each PURGE Each PURGE Principal Gas Gamma Emitters ) xx10 Grab Sample M H-3 lxi 01 W(2) W Principal Gas Gamma Emitters"b) 1x104
- 3. Unit Vent G rab S a m ple H-3_
H-3 _ _xi___
lx10"b_5 W Principal Gas Gamma Emitters') 1x10-4 4.a. Radwaste Facility Vent W
- b. Waste Handling Building Grab Sample
- c. Equipment Staging Building H-3 lx100
- 5. Unit Vents Continuous (b Dk*' 1-131 lx10 Charcoal Sample ___________________________
1-133 lxi 0" Continuoust 1 D(3 Principal Gamma Emittersb) lx10'u Particulate (1-131, Others)
Sample Continuous N M Gross Alpha(/) lx1011 Composite Particulate Sample Continuous") a Sr-89, Sr-90 lx10i Composite Particulate Sample McGuire Units 1 and 2 16.11.6-2 Revision 0
Dose Rate - Gaseous Effluents 16.11.6 TABLE 16.11.6-1 (Page 2 of 4)
RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Gaseous Release Type Sampling Frequency Minimum Analysis Type of Activity Analysis Lower Limit of Frequency Detection (LLD)(1 )
(RCi/ml)
- 6. All Release Types as listed in 4 above. Continuous N Wd) 1-131 1x10l, Charcoal Sample 1-133 lx10ou 11 Continuous*bl WtJ Principal Gamma Emitters"5' 1x10 Particulate (1-131, Others)
Sample Continuous*" M Gross Alpha('/ lxi 01 1 Composite Particulate Sample ContinuousI* Q Sr-89, Sr-90 1x10"11 Composite Particulate Sample McGuire Units 1 and 2 16.11.6-3 Revision 0
Dose Rate - Gaseous Effluents 16.11.6 TABLE 16.11.6-1 (Page 3 of 4)
NOTES:
- 1. The LLD is defined, for purposes of these commitments, as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system (which may include radiochemical separation):
LLD = 4.66 sb E. V .2.22 x 106
- Y- exp (-IAt)
Where:
LLD = the "a priori" lower limit of detection as defined above (as microCurie per unit mass or volume);
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute);
E = the counting efficiency (as counts per disintegration);
V = the sample size (in units of mass or volume);
2.22 x10 6= the number of disintegrations per minute per microCurie; Y = the fractional radiochemical yield (when applicable);
x = the radioactive decay constant for the particular radionuclide; and At = the elapsed time between midpoint of sample collection and time of counting (for plant effluents, not environmental samples).
Typical values of E, V, Y and At shall be used in the calculation.
It should be recognized that the LLD is defined as an "a priori" (before the fact) limit representing the capability of a measurement system and not as an "a posteriori" (after the fact) limit for a particular measurement.
McGuire Units 1 and 2 16.11.6-4 Revision 0
Dose Rate - Gaseous Effluents 16.11.6 TABLE 16.11.6-1 (Page 4 of 4)
NOTES:
- 2. Tritium grab samples shall be taken at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the refueling canal is flooded.
- 3. Samples shall be changed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing, or after removal from sampler.
- 4. Not used.
- 5. The ratio of the sample flow volume to the sampled stream flow volume shall be known for the time period covered by each dose or dose rate calculation made in accordance with SLCs 16.11.6, 16.11.8 and 16.11.9.
- 6. The principal gamma emitters for which the LLD specification applies include the following radionuclides: Kr-87, Kr-88, Xe-133, Xe-133m, Xe135, and Xe-138 in noble gas releases and Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, 1-131, Cs-1 34, Cs-1 37, 9
and Ce-141 in iodine and particulate releases. The LLD for Ce-144 is 5x10. microCi/ml.
This list does not mean that only these nuclides are to be considered. Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radioactive Effluent Release Report.
- 7. The composite filter(s) will be analyzed for alpha activity by analyzing the filter media used during the collection period.
- 8. Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing, or after removal from sampler. If the particulate and charcoal sample frequency is changed to a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> frequency the corresponding LLDs by a factor of 10 (i.e., LLD for 1-131 from 1 x 1012 to 1 x 1011 may be increased microCi/ml).
McGuire Units 1 and 2 16.11.6-5 Revision 0
Dose Rate - Gaseous Effluents 16.11.6 BASES Specific release rate limits restrict, at all times, the corresponding gamma and beta dose rates above background to a MEMBER OF THE PUBLIC at or beyond the SITE BOUNDARY to less than or equal to 500 mrem/year to the whole body, and 3000 mrem/year to the skin from noble gases, and 1500 mrem/year to any organ from Iodine 131, Iodine 133, tritium, and all radionuclides in particulate form with half-lives greater than eight days. This commitment applies to the release of gaseous effluents from all reactors at the site.
The basic requirements for the Selected Licensee Commitments concerning effluents from nuclear power reactors are stated in 10CFR50.36a. These requirements indicate that compliance with effluent Selected Licensee Commitments will keep average annual releases of radioactive material in effluents to small percentages of the limits specified in the old 10CFR20.106 (new 10CFR20.1301). These requirements further indicate that operational flexibility is allowed, compatible with considerations of health and safety, which may temporarily result in releases higher than such small percentages, but still within the limits specified in the old 10CFR20.106 which references Appendix B, Table II concentrations (MPCs). These referenced concentrations are specific values which relate to an annual dose of 500 mrem. It is further indicated in 10CFR50.36a that when using operational flexibility, best efforts shall be exerted to keep levels of radioactive materials in effluents as low as is reasonably achievable (ALARA) as set forth in 10CFR50, Appendix I.
As stated in the Introduction to Appendix B of the new 10CFR20, the effluent concentration (EC) limits given in Appendix B, Table 2, Column 1, are based on an annual dose of 50 mrem for isotopes for which inhalation or ingestion is limiting or 100 mrem for isotopes for which submersion (noble gases) is limiting. Since release concentrations corresponding to limiting dose rates of less than or equal to 500 mrem/year to the whole body, 3000 mrem/year to the skin from noble gases, and 1500 mrem/year to any organ from Iodine 131, Iodine 133, tritium and for all radionuclides in particulate form with half-lives greater than eight days at the site boundary has been acceptable as a SLC limit for gaseous effluents to assure that the limits of 10CFR50, Appendix I and 40CFR1 90 are not likely to be exceeded, it should not be necessary to restrict the operational flexibility by incorporating the EC value for isotopes based on ingestion/inhalation (50 mrem/year) or for isotopes with the EC based on submersion (100 mrem/year).
Having sufficient operational flexibility is especially important in establishing a basis for effluent monitor setpoint calculations. As discussed above, the concentrations stated in the new 10CFR20, Appendix B, Table 2, Column 1, relate to a dose of 50 or 100 mrem in a year. When applied on an instantaneous basis, this corresponds to a dose rate of either 50 or 100 mrem/year. These low values are impractical upon which to base effluent monitor setpoint calculations for many effluent release situations when monitor background, monitor sensitivity, and monitor performance must be taken into account. Therefore, to accommodate operational flexibility needed for effluent releases, the limits associated with SLC 16.11.6 will be maintained at the current dose rate limit for noble gases of 500 mrem/year to the whole body and 3000 mrem/year to the skin, for Iodine 131, Iodine 133, tritium and all radionuclides in particulate form with half-lives greater than eight days an instantaneous dose rate limit of 1500 mrem/year to any organ.
McGuire Units 1 and 2 16.11.6-6 Revision 0
Dose Rate - Gaseous Effluents 16.11.6 BASES (continued)
Compliance with the limits of the new 10CFR20.1301 will be demonstrated by operating within the limits of 1 OCFR50, Appendix I and 40CFR1 90. Operational history at Catawba/McGuire/Oconee has demonstrated that the use of the dose rate values listed above (i.e. 500 mrem/year, 3000 mrem/year and 1500 mrem/year) as SLC limits has resulted in calculated maximum individual doses to members of the public that are small percentages of the limits of 10CFR50, Appendix I and 40CFR1 90.
The required detection capabilities for radioactive materials in gaseous waste samples are tabulated in terms of the lower limits of detection (LLDs). Detailed discussion of the LLD, and other detection limits can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, L.A., "Limits for Qualitative Detection and Quantitative Determination Application to Radiochemistry," Anal. Chem. 40, 586-93. (1968), and Hartwell, J. K.
"Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).
REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 3. 10CFRPart 20
- 4. 10CFRPart50 McGuire Units 1 and 2 16.11.6-7 Revision 0
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.7 Radioactive Gaseous Effluent Monitoring Instrumentation COMMITMENT The radioactive gaseous effluent monitoring instrumentation channels shown in Table 16.11.7-1 shall be OPERABLE with Alarm/Trip I Setpoints set to ensure that the limits of SLC 16.11.6 are not exceeded.
AND The Alarm/Trip setpoints shall be determined and adjusted in accordance with the methodology and parameters in the ODCM.
TE -------------------------------------
NO---------------------------------------------.
Brief periods of routine sampling (not to exceed 15 minutes) do not make the instrumentation inoperable.
APPLICABILITY As shown in Table 16.11.7-1.
REMEDIAL ACTIONS
N OT E ----------------------------------------------------
Separate Condition entry is allowed for each Function.
CONDITION REQUIRED ACTION COMPLETION TIME A. One or more radioactive A.1 Suspend the release of Immediately gaseous effluent radioactive gaseous monitoring channels effluents monitored by the Alarm/Trip setpoint less affected channel.
conservative than required. OR A.2 Declare the channel Immediately inoperable.
OR A.3 Adjust setpoint to within Immediately limit.
(continued)
McGuire Units 1 and 2 16.11.7-1 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 RFMI='IAI ACTIONS (continued' CONDITION REQUIRED ACTION COMPLETION TIME B. One or more radioactive B.1 Enter the Remedial Action Immediately gaseous effluent specified in Table 16.11.7-1 monitoring instrument for the channel(s).
channels inoperable.
C. One channel C.1.1 Analyze two independent Prior to initiating a inoperable. samples of the tank release contents.
AND C.1.2 Perform independent Prior to initiating a verification of the discharge release valve lineup.
AND C.1.3.1 Perform independent Prior to initiating a verification of manual release portion of the computer input for the release rate calculations performed by computer.
OR C.1.3.2 Perform independent Prior to initiating a verification of entire release release rate calculations for calculations performed manually.
AND C.1.4 Restore channel to 14 days OPERABLE status.
OR C.2 Suspend the release of Immediately radioactive effluents via this pathway.
_____________________ _______________________ J _______________
(continued)
McGuire Units 1 and 2 16.11.7-2 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 RFMFI-lIAI ACTIONIS (cnntinued~
CONDITION REQUIRED ACTION COMPLETION TIME D. One or more flow rate D.1 Estimate the flow rate of Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> measurement channels the release. during releases inoperable.
AND D.2 Restore the channel to 30 days OPERABLE status.
E. One or more noble gas E.1 Obtain grab samples from Once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> activity monitor channels the effluent pathway. during releases inoperable.
AND E.2 Perform an analysis of grab Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> samples for gr-oss during releases radioactivity.
AND E.3 Restore the channel to 30 days OPERABLE status.
F. Noble gas activity F.1 Suspend PURGING or Immediately monitor providing VENTING of radioactive automatic termination of effluents via this pathway.
release inoperable.
G. One or more sampler G.1 Perform sampling with Continuously channels inoperable, auxiliary sampling equipment as required by Table 16.11.6-1.
AND G.2 Restore the channel to 30 days OPERABLE status.
(continued)
McGuire Units 1 and 2 16.11.7-3 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 REMEDIAL ACTIONS (continued CONDITION REQUIRED ACTION COMPLETION TIME H. One or more Sampler H.1 Verify flow through the Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Minimum Flow Device sampling apparatus. during releases Channels inoperable.
AND H.2 Restore the channel to 30 days OPERABLE status.
- 1. Required Action and 1.1 Explain why the In the next associated Completion inoperability was not scheduled Annual Time of Condition C, D, corrected within the Radioactive Effluent E, F, G, or H not met. specified Completion Time Release Report in the Annual Radioactive Effluent Release Report.
TESTING REQUIREMENTS
. NOTE ------------------------------------------------------
Refer to Table 16.11.7-1 to determine which TRs apply for each Radioactive Gaseous Effluent Monitoring channel.
TEST FREQUENCY TR 16.11.7.1 Perform CHANNEL CHECK. Prior to each release TR 16.11.7.2 -------------------------------- NOTE ----------------------------------- Prior to each The SOURCE CHECK for these channels shall be the release qualitative assessment of channel response when the channel sensor is exposed to a source of increased radioactivity or a simulated source of radioactivity such as a light emitting diode.
Perform SOURCE CHECK.
TR 16.11.7.3 Perform CHANNEL CHECK. 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> TR 16.11.7.4 Perform CHANNEL CHECK. 7 days (continued)
McGuire Units 1 and 2 16.11.7-4 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 TESTING REQUIREMENTS (continued)
TEST FREQUENCY TR 16.11.7.5 ------------------ NOTE ------------------
The SOURCE CHECK for these channels shall be the qualitative assessment of channel response when the channel sensor is exposed to a source of increased radioactivity or a simulated source of radioactivity such as a light emitting diode.
Perform SOURCE CHECK. 31 days TR 16.11.7.6 ------------------- NOTES----------------
- 1. For noble gas activity monitors providing automatic termination of release, the COT shall also demonstrate that automatic isolation of the pathway occurs if the instrument indicates measured levels above the Alarm/Trip Setpoint.
- 2. For all noble gas activity monitors, the COT shall also demonstrate that control room alarm annunciation occurs if the instrument indicates measured levels above the Alarm/Trip Setpoint; circuit failure and, a downscale failure.
Perform CHANNEL OPERATIONAL TEST. 92 days TR 16.11.7.7 ---------------- NOTE -------------------
For all noble gas activity monitors, the initial CHANNEL CALIBRATION shall be performed using standards certified by the National Institute of Standards and Technology (NIST) or using standards obtained from suppliers that participate in measurement assurance activities with NIST. These standards shall permit calibrating the system over its intended range of energy and measurement range. For subsequent CHANNEL CALIBRATION, sources that have been related to the initial calibration shall be used.
-.......................................................................... 18 m o nths Perform a CHANNEL CALIBRATION.
McGuire Units 1 and 2 16.11.7-5 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 TABLE 16.11.7-1 (Page 1 of 3)
RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION INSTRUMENTS MINIMUM REMEDIAL APPLICABILITY TESTING CHANNELS ACTION REQUIREMENTS OPERABLE
- 1. WASTE GAS HOLDUP SYSTEM
- a. Noble Gas Activity Monitor - 1 per station A, C, I During gas effluent TR 16.11.7.1 Providing Alarm and Automatic releases. TR 16.11.7.2 Termination of Release (Low Range- TR 16.11.7.6 EMF-50 or 1 EMF-36, low-range) TR 16.11.7.7
- b. Effluent System Flow Rate 1 per station D, I At all times except TR 16.11.7.3 Measuring Device when isolation TR 16.11.7.6 valve is closed & TR 16.11.7.7 locked.
- 2. Condenser Evacuation System - Noble 1 A, E, I When air ejectors TR 16.11.7.3 Gas Activity Monitor (EMF-33) are operable. TR 16.11.7.5 TR 16.11.7.6 TR 16.11.7.7
- 3. Vent System
- a. Noble Gas Activity Monitor (Low 1 A, E, I At all times. TR 16.11.7.3 Range - EMF-36) TR 16.11.7.5 TR 16.11.7.6 TR 16.11.7.7
- c. Particulate Sampler 1G, I At all times, except TR 16.11.7.4 during routine sampling.
- e. Particulate and Iodine Sampler 1 H,I At all times, except TR 16.11.7.3 Minimum Flow Device during routine TR 16.11.7.6 sampling. TR 16.11.7.7
- 4. Containment Purge System - Noble Gas 1 A, F, I Modes 1 through 6, TR 16.11.7.2 Activity Monitor - Providing Alarm and except when TR 16.11.7.3 Automatic Termination of Release (Low isolation valve is TR 16.11.7.6 Range - EMF-39) closed & locked. TR 16.11.7.7 (continued)
McGuire Units 1 and 2 16.11.7-6 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 TABLE 16.11.7-1 (Page 2 of 3)
RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION INSTRUMENTS MINIMUM REMEDIAL APPLICABILITY TESTING CHANNELS ACTION REQUIREMENTS OPERABLE
- 5. Auxiliary Building Ventilation System - 1 A, E, I At all times. TR 16.11.7.3 Noble Gas Activity Monitor (EMF-41 or TR 16.11.7.5 EMF-36) TR 16.11.7.6 TR 16.11.7.7
- 6. Fuel Storage Area Ventilation System - 1 A, E, I At all times. TR 16.11.7.3 Noble Gas Activity Monitor (EMF-42 or TR 16.11.7.5 EMF-36) TR 16.11.7.6 TR 16.11.7.7
- 7. Contaminated Parts Warehouse Ventilation System
- a. Noble Gas Activity Monitor (EMF-53) 1 per station A, E, I During gaseous TR 16.11.7.3 effluent releases. TR 16.11.7.5 TR 16.11.7.6 TR 16.11.7.7
- b. Flow Rate Monitor 1 per station D, I During gaseous TR 16.11.7.3 effluent releases. TR 16.11.7.6 TR 16.11.7.7
- c. EMF-53 Sampler Minimum Flow 1 per station H,I During gaseous TR 16.11.7.3 Device effluent releases. TR 16.11.7.6 TR 16.11.7.7
- 8. Radwaste Facility Ventilation System
- a. Noble Gas Activity Monitor (EMF-52) 1 per station A, E, I During gaseous TR 16.11.7.3 effluent releases. TR 16.11.7.5 TR 16.11.7.6 TR 16.11.7.7
- b. Flow Rate Monitor 1 per station D, I During gaseous TR 16.11.7.3 effluent releases. TR 16.11.7.6 TR 16.11.7.7
- c. EMF-52 Sampler Minimum Flow 1 per station H, I During gaseous TR 16.11.7.3 Device effluent releases. TR 16.11.7.6 TR 16.11.7.7 (continued)
McGuire Units 1 and 2 16.11.7-7 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 TABLE 16.11.7-1 (Page 3 of 3)
RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION INSTRUMENTS MINIMUM REMEDIAL APPLICABILITY TESTING CHANNELS ACTION REQUIREMENTS OPERABLE
- 9. Equipment Staging Building Ventilation System
- a. Noble Gas Activity Monitor (EMF-59) 1 per station A, E, I During gaseous TR 16.11.7.3 effluent releases. TR 16.11.7.5 TR 16.11.7.6 TR 16.11.7.7
- b. Flow Rate Monitor 1 per station D, I During gaseous TR 16.11.7.3 effluent releases. TR 16.11.7.6 TR 16.11.7.7
- c. EMF-59 Sampler Minimum Flow 1 per station H, I During gaseous TR 16.11.7.3 Device effluent releases. TR 16.11.7.6 TR 16.11.7.7
- 10. Containment Air Release and Addition 1 A, E, I At all times except TR 16.11.7.3 System - Noble Gas Activity Monitor when isolation TR 16.11.7.5 (EMF-39L or EMF-36L) valve is closed & TR 16.11.7.6 locked. TR 16.11.7.7 McGuire Units 1 and 2 16.11.7-8 Revision 12
Radioactive Gaseous Effluent Monitoring Instrumentation 16.11.7 BASES The radioactive gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents during actual or potential releases of gaseous effluents. During routine sampling, instrumentation may be turned off for short periods of time (not to exceed 15 minutes) in order to meet analysis requirements of SLC Manual 16.11.6. This is considered to be a normal operable function of the equipment. The Alarm/Trip Setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in the ODCM to ensure that the Alarm/Trip will occur prior to exceeding the limits stated in SLC 16.11.6. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.
REFERENCES
- 1. McGuire Nuclear Station, Offsite Dose Calculation Manual
- 2. 10 CFR Part 50, Appendix A McGuire Units 1 and 2 16.11.7-9 Revision 12
Noble Gases 16.11.8 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.8 Noble Gases COMMITMENT Air dose due to noble gases released in gaseous effluents, from each unit, to areas at and beyond the SITE BOUNDARY (see Figurel6.11.1-1) shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and
- b. During any calendar year: Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.
APPLICABILITY At all times.
REMEDIAL ACTIONS
-Nn r-.-,%-----------------------------------------------------
Enter applicable Conditions and Required Actions of SLC 16.11.12, "Total Dose," when the limits of this SLC are exceeded by twice the specified limit.
CONDITION REQUIRED ACTION COMPLETION TIME A. Calculated air dose from A.1 Prepare and submit a 30 days radioactive noble gases Special Report to the NRC in gaseous effluents which identifies the causes exceeding any of above for exceeding the limits, limits, corrective actions taken to reduce releases, and actions taken to ensure that subsequent releases are within limits.
McGuire Units 1 and 2 16.11.8-1 Revision 0
Noble Gases 16.11.8 TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.8.1 Determine cumulative dose contributions from noble 31 days gases in gaseous effluents for current calendar quarter and current calendar year in accordance with the methodology and parameters in the ODCM.
BASES This commitment is provided to implement the requirements of Sections II.B, III.A and IV.A of Appendix 1,10 CFR Part 50. The Limiting Condition for Operation implements the guides set forth in Section 11.B of Appendix I.
The REMEDIAL ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable."
The TESTING REQUIREMENTS implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially under-estimated.
The dose calculation methodology and parameters established in the ODCM for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water Cooled Reactors," Revision 1, July 1977.
The ODCM equations provided for determining the air doses at and beyond the SITE BOUNDARY are based upon the historical average atmospheric conditions.
This commitment applies at all times to the release of gaseous effluents from each reactor at the site. For units with shared Radwaste Treatment Systems, the gaseous effluents from the shared system are to be proportioned among the units sharing that system in accordance with the guidance given in NUREG-01 33, Chapter 3.1.
McGuire Units 1 and 2 16.11.8-2 Revision 0
Noble Gases 16.
11.8 REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 2. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.8-3 Revision 0
Dose - Iodine-131 and 133, Tritium and Radioactive Materials in Particulate Form 16.11.9 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.9 Dose - Iodine-1 31 and 133, Tritium and Radioactive Materials in Particulate Form COMMITMENT The dose to a MEMBER OF THE PUBLIC from Iodine-131 and 133, tritium, and all radioactive materials in particulate form with half-lives greater than 8 days in gaseous effluents released from each unit to areas at and beyond the SITE BOUNDARY (see Figure 16.11.1-1) shall be limited to the following:
- a. During any calendar quarter: less than or equal to 7.5 mrem to any organ, and
- b. During any calendar year: less than or equal to 15 mrem to any organ.
APPLICABILITY At all times.
REMEDIAL ACTIONS Enter applicable Conditions and Required Actions of SLC 16.11.12, "Total Dose," when the limits of this SLC are exceeded by twice the specified limit.
CONDITION REQUIRED ACTION COMPLETION TIME A. Calculated dose from A.1 Prepare and submit a 30 days the release of Iodine 131 Special Report to the NRC and 133, tritium, and which identifies the causes radioactive materials in for exceeding the limits, particulate form with corrective actions taken to half-lives greater than 8 reduce releases, and days in gaseous actions taken to ensure effluents exceeding any that subsequent releases of the above limits, are within limits.
McGuire Units 1 and 2 16.11.9-1 Revision 0
Dose - Iodine-131 and 133, Tritium and Radioactive Materials in Particulate Form 16.11.9 TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.9.1 Determine cumulative dose contributions for Iodine 131 31 days and 133, tritium, and radioactive material in particulate form with half lives greater than 8 days in gaseous effluents for current calendar quarter and current calendar year in accordance with the methodology and parameters in the ODCM.
BASES This commitment is provided to implement the requirements-of Sections- II.C, III.A and IV.A of Appendix 1,10 CFR Part 50. The Limiting Conditions for Operation are the guides set forth in Section II.C of Appendix I.
The REMEDIAL ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive materials in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable.
The ODCM calculational methods specified in the TESTING REQUIREMENTS implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated.
The ODCM calculational methodology and parameters for calculating the doses due to the actual release rates of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water Cooled Reactors, Revision 1, July 1977. These equations also provide for determining the actual doses based upon the historical average atmospheric conditions.
The release rate specifications for Iodine-131 and 133, tritium, and radionuclides in particulate form with half-lives greater than 8 days are dependent upon the existing radionuclide pathways to man, in the areas at and beyond the SITE BOUNDARY. The pathways that were examined in the development of these calculations were: (1) individual inhalation of airborne radionuclides; (2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man; (3) deposition onto grassy areas where milk animals and meat-producing animals graze with consumption of the milk and meat by man; and, (4) deposition on the ground with subsequent exposure of man.
McGuire Units 1 and 2 16.11.9-2 Revision 0
Dose - Iodine-131 and 133, Tritium and Radioactive Materials in Particulate Form 16.11.9 BASES (continued)
This commitment applies at all times to the release of gaseous effluents from each reactor at the site. For units with shared Radwaste Treatment Systems, the gaseous effluents from the shared system are to be proportioned among the units sharing that system in accordance with the guidance given in NUREG 0133, Chapter 3.1.
REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 2. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.9-3 Revision 0
Gaseous Radwaste Treatment System 16.11.10 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.10 Gaseous Radwaste Treatment System COMMITMENT The VENTILATION EXHAUST TREATMENT and WASTE GAS HOLDUP SYSTEMS shall be OPERABLE and appropriate portions of these systems shall be used to reduce releases of radioactivity when the projected doses in 31 days due to gaseous effluent releases, from each unit, to areas at and beyond the SITE BOUNDARY (see Figure 16.11.1 -1) would exceed:
- a. 0.2 mrad to air from gamma radiation, or
- b. 0.4 mrad to air from beta radiation, or
- c. 0.3 mrem to any organ of a MEMBER OF THE PUBLIC.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Radioactive gases being A.1 Prepare and submit a 30 days discharged without Special Report to the NRC treatment and in excess which identifies inoperable of above limits, equipment and reasons for inoperability, actions taken to restore the equipment to OPERABLE status, and actions taken to prevent recurrence.
McGuire Units 1 and 2 16.11.10-1 Revision 0
Gaseous Radwaste Treatment System 16.11.10 TESTING REQUIREMENTS
NOTE ------------------------------------------------
The installed Gaseous Radwaste Treatment System shall be demonstrated OPERABLE by meeting SLC 16.11.6, 16.11.8 and16.11.9.
TEST FREQUENCY TR 16.11.10.1 Project gaseous release doses from each unit to areas 31 days at and beyond the SITE BOUNDARY, in accordance with the methodology and parameters in the ODCM, when gaseous systems are being released without being processed by its radwaste treatment system.
BASES The OPERABILITY of the WASTE GAS HOLDUP SYSTEM and the VENTILATION EXHAUST TREATMENT SYSTEM ensures that the systems will be available for use whenever gaseous effluents require treatment prior to release to the environment. The requirement that the appropriate portions of these systems be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable."
This commitment implements the requirements of 19 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50 and the design objectives given in Section IL.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the systems were specified as a suitable fraction of the dose design objectives set forth in Section II.B and IL.C of Appendix 1,10 CFR Part 50, for gaseous effluents.
This commitment applies at all times to the release of radioactive materials in gaseous effluents from each unit at the site. For units with shared Radwaste Treatment Systems, the gaseous effluents from the shared system are to be proportioned among the units sharing that system in accordance with NUREG-0133, Chapter 3.1.
REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 3. 10CFRPart 50 McGuire Units 1 and 2 16.11.10-2 Revision 0
Solid Radioactive Waste 16.11.11 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.11 Solid Radioactive Waste COMMITMENT Radioactive wastes shall be solidified or dewatered in accordance with the PROCESS CONTROL PROGRAM to meet shipping and transportation requirements during transit, and disposal site requirements when received at the disposal site.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Solidification or A.1 Suspend shipment of Immediately dewatering not meeting inadequately processed disposal site or shipping waste.
and transportation requirements. AND A.2 Initiate action to correct the Immediately PROCESS CONTROL PROGRAM, procedures, or Solid Waste System as necessary to prevent recurrence.
B. Solidification or B.1 Initiate action to test Immediately dewatering not improperly processed performed in accordance waste in each container to with the PROCESS ensure burial ground and CONTROL PROGRAM. shipping requirements are met.
AND B.2 Initiate appropriate Immediately administrative action to prevent recurrence.
(continued)
McGuire Units 1 and 2 16.11.11-1 Revision 0
Solid Radioactive Waste 16.11.11 REMEDIAL ACTIONS (continued' ACIN1cniud REEDA C. Installed solidification or C.1 Initiate action to restore the Immediately dewatering equipment equipment to OPERABLE inoperable. status.
OR C.2 Initiate action to provide for Immediately contract capability to process wastes as necessary to satisfy all applicable transportation and disposal requirements.
J _________________________ - ________________
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.11.1 -------------------------------- NOTES----------------
- 1. If any test specimen fails, the SOLIDIFICATION of the batch under test shall be suspended until such time as additional test specimens can be obtained, alternative SOLIDIFICATION parameters can be determined in accordance with the PROCESS CONTROL PROGRAM, and a subsequent test verifies SOLIDIFICATION.
- 2. If the initial test specimen from a batch of waste fails to verify SOLIDIFICATION, the PROCESS CONTROL PROGRAM shall provide for the collection and testing of representative test specimens from each consecutive batch of the same type of wet waste until at least three consecutive initial test specimens demonstrate SOLIDIFICATION.
SOLIDIFICATION of at least one representative test In accordance with specimen from at least every tenth batch of each type of the PROCESS wet radioactive wastes (e.g., filter sludges, spent resins, CONTROL evaporator bottoms, boric acid solutions and sodium PROGRAM sulfate solutions) shall be verified in accordance with the PROCESS CONTROL PROGRAM.
McGuire Units 1 and 2 16.11.11-2 Revision 0
Solid Radioactive Waste 16.11.11 BASES This commitment implements the requirements of 10 CFR Part 50.36a and General Design Criterion 60 of Appendix A to 10 CFR Part 50. The process parameters included in establishing the PROCESS CONTROL PROGRAM may include, but are not limited to waste type, waste pH, waste/liquid/solidification agent/catalyst ratios, waste oil content, waste principal chemical constituents, and mixing and curing times.
If any test specimen fails to verify SOLIDIFICATION, the SOLIDIFICATION of the batch under test shall be suspended until such time as additional test specimens can be obtained, alternative SOLIDIFICATION parameters can be determined in accordance with the PROCESS CONTROL PROGRAM, and a subsequent test verifies SOLIDIFICATION.
SOLIDIFICATION of the batch may then be resumed using the alternative SOLIDIFICATION parameters determined by the PROCESS CONTROL PROGRAM.
If the initial test specimen from a batch of waste fails to verify SOLIDIFICATION, the PROCESS CONTROL PROGRAM shall provide for the collection and testing of representative test specimens from each consecutive batch of the same type of wet waste until at least three consecutive initial test specimens demonstrate SOLIDIFICATION.
The PROCESS CONTROL PROGRAM shall be modified as required to assure SOLIDIFICATION of subsequent batches of waste.
Licensee-initiated changes to the PROCESS CONTROL PROGRAM:
- 1. Shall be documented and records of reviews performed shall be retained as required by the Quality Assurance Plan. This documentation shall contain:
- a. Sufficient information to support the change together with the appropriate analyses or evaluations justifying the change(s) and
- b. A determination that the change will maintain the overall conformance of the solidified waste product to existing requirements of Federal, State, or other applicable regulations.
- 2. Shall become effective upon review and acceptance by the Station Manager and a qualified individual/organization.
Written procedures shall be established, implemented, and maintained for the PROCESS CONTROL PROGRAM implementation.
REFERENCES
- 2. 10CFRPart50
- 3. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.11-3 Revision 0
Total Dose 16.11.12 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.12 Total Dose COMMITMENT The annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC, due to releases of radioactivity and radiation, from uranium fuel cycle sources shall be limited to < 25 mrem to the whole body or any organ, except the thyroid, which shall be limited to < 75 mrem.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Calculated doses from A.1 Verify, by calculation, the Immediately releases exceeding cumulative dose from direct twice the specified limits radiation contributions and of SLC 16.11.3, 16.11.8 outside storage tanks and or 16.11.9. radioactivity releases are within the total dose limit.
AND A.2 ---------- NOTE-----
Only required to be performed if the total dose limit is exceeded.
Prepare and submit a 30 days Special Report to the NRC which identifies corrective actions to be taken to reduce subsequent releases to prevent recurrence and schedule for achieving conformance with specified limits.
McGuire Units 1 and 2 16.11.12-1 Revision 0
Total Dose 16.11.12 TESTING REQUIREMENTS
-NO TE OTE----------------------------
Cumulative dose contributions from liquid and gaseous effluents shall be determined in accordance with SLC 16.11.3, 16.11.8 andl6.11.9, and in accordance with the methodology and parameters specified in the ODCM.
TEST FREQUENCY TR 16.11.12.1 Determine cumulative dose contributions from direct When calculated radiation from the units and from radwaste storage tanks doses from in accordance with the methodology and parameters effluent releases specified in the ODCM. exceeds twice the limits of SLCs 16.11.3, 16.11.8 or 16.11.9 BASES This commitment is provided to meet the dose limitations of 40 CFR Part 190 that have been incorporated into 10 CFR Part 20 by 46 FR 18525. The specification requires the preparation and submittal of a Special Report whenever the calculated doses from plant generated radioactive effluents and direct radiation exceed 25 mrem to the whole body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrem. For sites containing up to four reactors, it is highly unlikely that the resultant dose to a MEMBER OF THE PUBLIC will exceed the dose limits of 40 CFR Part 190 if the individual reactors remain within twice the dose design objectives of 10 CFR Part 50, Appendix I, and if direct radiation doses from the units and outside storage tanks are kept small.
This Special Report, as defined in 10 CFR Part 20.2203(a)(4), shall include an analysis that estimates the radiation exposure (dose) to a MEMBER OF THE PUBLIC from uranium fuel cycle sources, including all effluent pathways and direct radiation, for the calendar year that includes the release(s) covered by this report. It shall also describe levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations. The Special Report will describe a course of action that should result in the limitation of the annual dose to a MEMBER OF THE PUBLIC to within the 40 CFR Part 190 limits. For the purposes of the Special Report, it may be assumed that the dose commitment to the MEMBER of the PUBLIC from other uranium fuel cycle sources is negligible, with the exception that dose contributions from other nuclear fuel cycle facilities at the same site or within a radius of 8 km must be considered.
If the dose to any MEMBER OF THE PUBLIC is estimated to exceed the requirements of 40 CFR Part 190, the Special Report with a request for a variance (provided the release conditions resulting in violation of 40 CFR Part 190 have not already been corrected), in McGuire Units 1 and 2 16.11.12-2 Revision 0
Total Dose 16.11.12 BASES (continued) accordance with the provisions of 40 CFR Part 190.11 and 10 CFR Part 20.2203(a)(4), is considered to be a timely request and fulfills the requirements of 40 CFR Part 190 and a variance is granted until NRC staff action is completed. The variance only relates to the limits of 40 CFR Part 190, and does not apply in any way to the other requirements for dose limitation of 10 CFR Part 20, as addressed in SLCs 16.11.1 and 16.11.6.
An individual is not considered a MEMBER OF THE PUBLIC during any period in which he/she is engaged in carrying out any operation that is part of the nuclear fuel cycle.
REFERENCES
- 1. McGuire Nuclear Station, Offsite Dose Calculation Manual
- 2. 10CFRPart20
- 3. 40 CFR Part 190
- 4. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.12-3 Revision 0
Radiological Environmental Monitoring Program 16.11.13 16.11 RADIOLOGICAL EFFLUENT MONITORING 16.11.13 Radiological Environmental Monitoring Program COMMITMENT The Radiological Environmental Monitoring Program shall be conducted as specified in Table 16.11.13-1.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Radiological A.1 Identify the reasons for not Within the next Environmental conducting the program as scheduled Annual Monitoring Program not required and the plans for Radiological being conducted as preventing a recurrence in Environmental specified in Table the Annual Radiological Operating Report 16.11.13-1. Environmental Operating Report.
B. Radioactivity level of B.1 Prepare and submit a 30 days environmental sampling Special Report that defines medium at a specified the corrective actions to be location in excess of taken to reduce radioactive reporting limits of Table effluents so that the 16.11.13-2. potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year limits of SLC 16.11.6, 16.11.8, and 16.11.9.
(continued)
McGuire Units 1 and 2 16.11.13-1 Revision 0
Radiological Environmental Monitoring Program 16.11.13 REMEDIAL ACTIONS (continued CONDITION REQUIRED ACTION COMPLETION TIME C. Milk or fresh leafy C.1 ---------- NOTE------
vegetable samples Specific locations from unavailable from one or which samples were more required sample unavailable may be deleted locations, from the program.
Revise the Radiological 30 days Environmental Monitoring Program to identify locations for obtaining replacement samples.
AND C.2 Identify the cause of the Within the next unavailability of samples scheduled Annual and identify new location(s) Radioactive Effluent for obtaining replacement Release Report samples in the next Annual Radioactive Effluent Release Report and also include in the report a revised figure(s) and table for the ODCM reflecting the new location(s).
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.13.1 ------------------ NOTES----------------
The maximum values for the lower limits of detection shall be as specified in Tablel6.11.13-3.
The radiological environmental monitoring samples shall In accordance with be collected from the locations given in the table and Table 16.11.13-1 figure in the ODCM and shall be analyzed pursuant to the requirements of Tablesl6.11.13-1.
McGuire Units 1 and 2 16.11.13-2 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-1 (Page 1 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND FREQUENCY PATHWAY AND/OR AND SAMPLE LOCATIONS(') COLLECTION OF ANALYSIS SAMPLE FREQUENCY
- 1. Direct Radiation(2) Forty routine monitoring stations either with Quarterly Gamma dose quarterly.
two or more dosimeters or with one instrument for measuring and recording dose rate continuously, placed as follows:
An inner ring of stations, one in each meteorological sector in the general area of the SITE BOUNDARY; An outer ring of stations, one in each meteorological sector in the 6- to 8-km range from the site; and The balance of the stations placed in special interest areas such as population centers, nearby residences, schools, and in one or two areas to serve as control stations.
(continued)
McGuire Units 1 and 2 16.11.13-3 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-1 (Page 2 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND FREQUENCY PATHWAY AND/OR AND SAMPLE LOCATIONS(1 ) COLLECTION OF ANALYSIS SAMPLE FREQUENCY
- 2. Airborne Samples from five locations: Continuous sampler Radioiodine Canister:
Radioiodine and operation with sample 1-131 analysis weekly.
Particulates Three samples from close to the three SITE collection weekly, or BOUNDARY locations, in different sectors, of more frequently if Particulate Sampler:
the highest calculated annual average required by dust Gross beta radioactivity ground level D/Q. loading, analysis following filter change(4); Gamma isotopic One sample from the vicinity of a community analysis(5) of composite (by having the highest calculated annual average location quarterly).
ground level D/Q.
One sample from a control location, as for example 15-30 km distant _(3) and in the least prevalent wind direction .
- 3. Waterborne One sample upstream. Composite sample Gamma isotope analysis(5) 7 ).
- a. Surface(6 ) One sample downstream. over 1-month period~ monthly. Composite for tritium analysis quarterly.
- b. Ground Samples from one or two sources only if Quarterly Gamma isotopic(5 ) and likely to be affected(8) tritium analysis quarterly.
(continued)
McGuire Units 1 and 2 16.11.13-4 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-1 (Page 3 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND FREQUENCY PATHWAY AND/OR AND SAMPLE LOCATIONS(1 ) COLLECTION OF ANALYSIS SAMPLE FREQUENCY
- c. Drinking One sample of each of one to three of the Composite sample 1-131 analysis on each nearest water supplies that could be affected over 2-week period(7 ) composite when the dose by its discharge. when 1-131 analysis is calculated for the performed; monthly consumption of the water is One sample from a control location, composite otherwise. greater than 1 mrem per year(9). Composite for gross beta and gamma isotopic analyses(5 monthly.
Composite for tritium analysis quarterly.
- d. Sediment from One sample from downstream area with Semiannually Gamma isotopic analysis(5 )
the shoreline existing or potential recreational value. semiannually.
- 4. Ingestion Samples from milking animals in three Semimonthly when Gamma isotopic(5) and 1-131
- a. Milk locations within 5-km distance having the animals are on analysis semimonthly when highest dose potential. If there are none, pasture; monthly at animals are on pasture; then one sample from milking animals in other times. monthly at other times.
each of three areas between 5 to 8 km distant where doses are calculated to be greater than 1 mrem per year(9)
One sample from milking animals at a control location 15 to 30 km distant and in the least prevalent wind direction.
(continued)
McGuire Units 1 and 2 16.11.13-5 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-1 (Page 4 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND FREQUENCY PATHWAY AND/OR AND SAMPLE LOCATIONS(1 ) COLLECTION OF ANALYSIS SAMPLE FREQUENCY
- b. Fish and One sample each commercially and Sample in season, or Gamma isotopic analysis(5 )
Invertebrates recreationally important species in vicinity of semiannually if they on edible portions plant discharge area. are not seasonal One sample of same species in areas not influenced by plant discharge.
- c. Food Products One sample of each principal class of food At time of harvest(10 ) Gamma isotopic analyses(5 )
products from any area that is irrigated by on edible portion.
water in which liquid plant wastes have been discharged.
Samples of three different kinds of broad leaf Monthly, when Gamma isotopic(5) and 1-131 vegetation grown nearest each of two available, analysis.
different offsite locations of highest predicted annual average ground level D/Q if milk sampling is not performed.
One sample of each of the similar broad leaf Monthly, when Gamma isotopic(5) and 1-131 vegetation grown 15 to 30 km distant in the available, analysis.
least prevalent wind direction if milk sampling is not performed.
McGuire Units 1 and 2 16.11.13-6 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-1 (Page 5 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM NOTES:
- 1. Specific parameters of distance and direction sector from the centerline of one reactor, and additional description where pertinent, shall be provided for each and every sample location in Table 16.11.13-1 in a table and figure(s) in the ODCM. Refer to NUREG 0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants," October 1978, and to Radiological Assessment Branch Technical Position, Revision 1, November 1979. Deviations are permitted from the required sampling schedule if specimens are unobtainable due to hazardous conditions, seasonal unavailability, malfunction of automatic sampling equipment and other legitimate reasons. If specimens are unobtainable due to sampling equipment malfunction, every effort shall be made to complete corrective action prior to the end of the next sampling period. All deviations from the sampling schedule shall be documented in the Annual Radiological Environmental Operating Report. It is recognized that, at times, it may not be possible or practical to continue to obtain samples of the media of choice at the most desired location or time. In these instances suitable alternative media and locations may be chosen for the particular pathway in question and appropriate substitutions made within 30 days in the Radiological Environmental Monitoring Program. In lieu of an Licensee Event Report, identify the cause of the unavailability of samples for that pathway and identify the new locations(s) for obtaining replacement samples in the next Annual Radioactive Effluent Release Report and also include in the report a revised figure(s) and table for the ODCM reflecting the new location(s).
- 2. One or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously may be used in place of, or in addition to, integrating dosimeters. For the purposes of this table, a thermoluminescent dosimeter (TLD) is considered to be one phosphor; two or more phosphors in a packet are considered as two or more dosimeters. Film badges shall not be used as dosimeters for measuring direct radiation. The forty stations is not an absolute number. The number of direct radiation monitoring stations may be reduced according to geographical limitations; e.g.,
at an ocean site, some sections will be over water so that the number of dosimeters may be reduced accordingly. The frequency of analysis or readout for TLD systems will depend upon the characteristics of the specific system used and should be selected to obtain optimum dose information with minimal fading.
- 3. The purpose of this sample is to obtain background information. If it is not practical to establish control locations in accordance with the distance and wind direction criteria, other sites that provide valid background data may be substituted.
- 4. Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.
McGuire Units 1 and 2 16.11.13-7 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-1 (Page 6 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM NOTES (continued):
- 5. Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.
- 6. The "upstream sample" shall be taken at a distance beyond significant influence of the discharge. The "downstream" sample shall be taken in an area beyond but near the mixing zone. "Upstream" samples in an estuary must be taken far enough upstream to be beyond the plant influence. Salt water shall be sampled only when the receiving water is utilized for recreational activities.
- 7. A composite sample is one in which the quantity (aliquot) of liquid sampled is proportional to the quantity of flowing liquid and in which the method of sampling employed results in a specimen that is representative of the liquid flow. In this program composite sample aliquots shall be collected at time intervals that are very short (e.g.,
hourly) relative to the compositing period (e.g., monthly) in order to assure obtaining a representative sample.
- 8. Groundwater samples shall be taken when this source is tapped for drinking or irrigation purposes in areas where the hydraulic gradient or recharge properties are suitable for contamination.
- 9. The dose shall be calculated for the maximum organ and age group, using the methodology and parameters in the ODCM.
- 10. If harvest occurs more than once a year, sampling shall be performed during each discrete harvest. If harvest occurs continuously, sampling shall be monthly. Attention shall be paid to including samples of tuborous and root food products.
McGuire Units 1 and 2 16.11.13-8 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-2 (Page 1 of 1)
REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES REPORTING LEVELS ANALYSIS WATER WATER AIRBOURNE FISH MILK BFIOAD LEAF (pCi/I) PARTICULATE OR (pCi/kg, wet) (pCi/I) VE-GETATION GASES (pCi/m 3) (riCi/kg, wet)
ANALYSIS 20,000{1" H-3 N/A N/A N/A N/A Mn-54 1,000 N/A 30,000 N/A N/A Fe-59 400 N/A 10,000 N/A N/A Co-58 1,000 N/A 30,000 N/A N/A Co-60 300 N/A 10,000 N/A N/A Zn-65 300 N/A 20,000 N/A N/A Zr-Nb-95 400 N/A N/A N/A N/A 1-131 2 1 N/A 3 100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 N/A N/A 300 N/A NOTES:
- 1. For drinking water samples. This is 40 CFR Part 141 value. If no drinking water pathway exists, a value of 30,000 pCi/I may be used.
McGuire Units 1 and 2 16.11.13-9 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-3 (Page 1 of 3)
MAXIMUM VALUES FOR THE LOWER LIMITS OF DETECTION (LLD) (1)(2)(3)
ANALYSIS WATER AIRBORNE FISH MILK BROAD LEAF SEDIMENT (pCi/I) PARTICULATE (pCi/kg, wet) (pCi/I) VEGETATION (pCi/kg, dry)
OR GASES (pCi/kg, wet)
(pCi/m 3 )
Gross Beta 4 N/A N/A N/A N/A N/A H-3 2000* N/A N/A N/A N/A N/A Mn-54 15 N/A 130 N/A N/A N/A Fe-59 30 N/A 260 N/A N/A N/A Co-58, 60 15 N/A 130 N/A N/A N/A Zn-65 30 N/A 260 N/A N/A N/A Zr-95 15 N/A N/A N/A N/A N/A Nb-95 15 N/A N/A N/A N/A N/A 1-131 1(4) 0.07 N/A 1 60 N/A Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-140 15 N/A N/A 15 N/A N/A La- 140 15 N/A N/A 15 N/A N/A
- If no drinking water pathway exists, a value of 3000 pCi/I may be used.
McGuire Units 1 and 2 16.11.13-10 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-3 (Page 2 of 3)
MAXIMUM VALUES FOR THE LOWER LIMITS OF DETECTION (LLD)
NOTES:
- 1. The LLD is defined, for purposes of these commitments, as the smallest concentration of radioactive material in a sample that will yield a net count (above system background) that will be detected with 95% probability with 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system (which may include radiochemical separation):
LLD = 4.66 sb E- V- 2.22. Y exp (-AAt)
Where:
LLD is the "a priori" lower limit of detection as defined above (as picoCurie per unit mass or volume),
Sb is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute),
E is the counting efficiency (as counts per disintegration),
V is the sample size (in units of mass or volume),
2.22 is the number of disintegrations per minute per picoCurie, Y is the fractional radiochemical yield (when applicable),
- X is the radioactive decay constant for the particular radionuclide, and At is the elapsed time between sample collection (or end of the sample collection period) and time of counting (for environmental samples, not plant effluent samples).
It should be recognized that the LLD is defined as an a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement. Analyses shall be performed in such a manner that the stated LLDs will be achieved under routine conditions.
Occasionally background fluctuations, unavoidable small sample sizes, the presence of interfering nuclides, or other uncontrollable circumstances may render these LLDs unachievable. In such cases, the contributing factors shall be identified and described in the Annual Radiological Environmental Operating Report.
McGuire Units 1 and 2 16.11.13-11 Revision 0
Radiological Environmental Monitoring Program 16.11.13 TABLE 16.11.13-3 (Page 3 of 3)
MAXIMUM VALUES FOR THE LOWER LIMITS OF DETECTION (LLD)
NOTES (continued):
- 2. This list does not mean that only these nuclides are to be considered. Other peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating Report.
- 3. Required detection capabilities for thermoluminescent dosimeters used for environmental measurements shall be in accordance with the recommendations of Regulatory Guide 4.13.
- 4. LLD for drinking water samples. If no drinking water pathway exists, the LLD of gamma isotopic analysis may be used.
McGuire Units 1 and 2 16.11.13-12 Revision 0
Radiological Environmental Monitoring Program 16.11.13 BASES The Radiological Environmental Monitoring Program is established to monitor the radiation and radionuclides in the environs of the plant. The program provides representative measurements of radioactivity in the highest potential exposure pathways, and verification of the accuracy of the effluent monitoring program and modeling of environmental exposure pathways. The program is contained in SLC 16.11.13 - 16.11.16 and conforms to the guidance of Appendix I to 10 CFR Part 50.
The program includes the following:
- 1. Monitoring, sampling, analysis, and reporting of radiation and radionuclides in the environment in accordance with the methodology and parameters in the ODCM,
- 2. A Land Use Census to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the monitoring program are made if required by the results of this census, and
- 3. Participation in an Interlaboratory Comparison Program to ensure that independent checks on the precision and accuracy of the measurements of radioactive materials in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring.
The portion of the Radiological Environmental Monitoring Program required by this commitment provides representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides that lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from the station operation. This monitoring program implementsSection IV.B.2 of Appendix I to 10 CFR Part 50 and thereby supplements the Radiological Effluent Monitoring Program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways. Guidance for this monitoring program is provided by the Radiological Assessment Branch Technical Position on Environmental Monitoring. The initially specified monitoring program will be effective for at least the first 3 years of commercial operation. Following this period, program changes may be initiated based on operational experience.
The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs). The LLDs required by Table 16.11.13-3 are considered optimum for routine environmental measurements in industrial laboratories. It should be recognized that the LLD is defined as an'a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.
With the level of radioactivity in an environmental sampling medium at a specified location exceeding the reporting levels of Table 16.11.13-3 when averaged over any calendar quarter, in lieu of a Licensee Event Report, prepare and submit to the Commission within 30 days a Special Report that defines the corrective actions to be McGuire Units 1 and 2 16.11.13-13 Revision 0
Radiological Environmental Monitoring Program 16.11.13 BASES (continued) taken to reduce radioactive effluents so that the potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year limits of SLCs 16.11.6, 16.11.8, and 16.11.9. When more than one of the radionuclides in Table 16.11.13-2 are detected in the sampling medium, this report shall be submitted if:
concentration (1) + concentration (2) + ...... > 1.0 limit level (1) limit level (2)
When radionuclides other than those in Table 16.11.13-2 are detected and are the result of plant effluents, this report shall be submitted if the potential annual dose to a MEMBER OF THE PUBLIC is equal to or greater than the calendar year limits of SLCs 16.11.6, 16.11.8 and 16.11.9. This report is not required if the measured level of radioactivity was not the result of plant effluents; however, in such an event, the condition shall be reported and described in the Annual Radiological Environmental Operating Report. The methodology and parameters used to estimate the potential annual dose to a MEMBER OF THE PUBLIC shall be indicated in this report.
Detailed discussion of the LLD, and other detection limits, can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, L. A., "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry," Anal. Chem.
40, 586-93 (1968), and Hartwell, J. K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).
REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 2. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.13-14 Revision 0
Land Use Census 16.11.14 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.14 Land Use Census COMMITMENT A land use census shall be conducted and shall identify within a distance of 8 km (5 miles) the location in each of the 16 meteorological sectors of:
- a. the nearest milk animal,
- b. the nearest residence, and
- c. the nearest garden of greater than 50 m 2 (500 ft2 ) producing broad leaf vegetation.
For elevated releases as defined in Regulatory Guide 1.111, Revision 1, July 1977, the land use census shall identify within a distance of 5 km (3 miles) the location in each of the 16 meteorological sectors of:
- a. all milk animals, and
- b. all gardens of greater than 50 m 2 producing broad leaf vegetation.
-NOTE Broad leaf vegetation sampling of three different kinds of vegetation may be performed at the SITE BOUNDARY in each of two different direction sectors with the highest predicted D/Qs in lieu of the garden census. Specifications for broad leaf vegetation sampling in Table 16.11.13-1 4c shall be followed, including analysis of control samples.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Location(s) identified A.1 Identify the new location in In next scheduled which yields a calculated the Annual Radioactive Annual Radioactive dose/dose commitment Effluent Release Report. Effluent Release greater than values Report currently calculated in SLC 16.11.9.
(continued)
McGuire Units 1 and 2 16.11.14-1 Revision 21
Land Use Census 16.11.14 RFMFDIAL ACTIONS (continued' RE CIN cniud TDA B. Location(s) identified B.1 Add the new location to the 30 days which yields a Radiological Environmental calculated dose or dose Monitoring Program.
commitment (via same exposure pathway) 20% AND greater than at a location from which samples are B.2 ---- -----------
NOTES-----
currently being obtained If samples cannot be in accordance with SLC obtained, an explanation of 16.11.13. why samples are not obtainable (substitute representative locations if possible) shall be included.
Identify the new In the next location(s), revised figures scheduled Annual and tables for the ODCM, Radiological Release in the next Annual Report Radiological Release Report.
I ________________________________
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.14.1 ----------------------------- NOTE ---------------------------------
The results of the land use census shall be included in the Annual Radiological Environmental Operating Report.
Conduct a land use census during the growing season 12 months using the information which will provide the best results such as a door-to-door survey, aerial survey, or consultation with local agricultural authorities.
McGuire Units 1 and 2 16.11.14-2 Revision 21
Land Use Census 16.11.14 BASES This commitment is provided to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the Radiological Environmental Monitoring Program are made if required by the results of this census. The best information from the door-to-door survey, from aerial survey, or from consulting with local agricultural authorities shall be used. This census satisfies the requirements of Section IV.B.3 of 2 m
Appendix I to 10 CFR Part 50. Restricting the census to gardens of greater than 50 provides assurance that significant exposure pathways via leafy vegetables will be identified and monitored since a garden of this size is the minimum required to produce the quantity (26 kg/year) of leafy vegetables assumed in Regulatory Guide 1.109 for consumption by a child. To determine this minimum garden size, the following assumptions were made: (1) 20% of the garden was used for growing broad leaf vegetation (i.e., similar to lettuce and cabbage), and (2) a vegetation yield of 2 kg/m 2.
With a land use census identifying a location(s) which yields a calculated dose or dose commitment (via the same exposure pathway) 20% greater than at a location from which samples are currently being obtained in accordance with SLC 16.11.13, add the new location to the Radiological Environmental Monitoring Program. The sampling location(s),
excluding the control station location, having the lowest calculated dose or dose commitment (via the same exposure pathway) may be deleted from this monitoring program after October 31 of the year in which this land use census was conducted.
REFERENCES
- 1. McGuire Nuclear Station, Off site Dose Calculation Manual
- 2. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.14-3 Revision 21
Interlaboratory Comparison Program 16.11.15 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.15 Interlaboratory Comparison Program COMMITMENT Analyses shall be performed on radioactive materials, supplied as part of an Interlaboratory Comparison Program (ICP), that correspond to samples required by SLC 16.11.13.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Analyses not being A.1 Report corrective actions In next scheduled performed as required. taken to prevent recurrence Annual Radiological in the Annual Radiological Environmental Environmental Operating Operating Report Report.
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.15.1 Report a summary of the results of the Interlaboratory 12 months Comparison Program in the Annual Radiological Environmental Operating Report.
McGuire Units 1 and 2 16.11.15-1 Revision 21
Interlaboratory Comparison Program 16.11.15 BASES This requirement for participation in an Interlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring in order to demonstrate that the results are valid for the purposes of Section IV.B.2 of Appendix I to 10 CFR Part 50.
The Interlaboratory Comparison Program (ICP) shall be described in the Annual Radiological Environmental Operating Report.
REFERENCES
- 1. 10 CFR Part 50, Appendix I McGuire Units 1 and 2 16.11.15-2 Revision 21
Annual Radiological Environmental Operating Report 16.11.16 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.16 Annual Radiological Environmental Operating Report COMMITMENT Routine Annual Radiological Environmental Operating Reports covering the operation of the unit during the previous calendar year shall be submitted prior to May 15 of each year.
The Annual Radiological Environmental Operating Reports shall include summaries, interpretations, and an analysis of trends of the results of the radiological environmental surveillance activities for the report period, including a comparison with pre-operational studies, with operational controls as appropriate, and with previous environmental surveillance reports, and an assessment of the observed impacts of the plant operation on the environment. The reports shall also include the results of land use censuses required by SLC 16.11.14.
The Annual Radiological Environmental Operating Reports shall include the results of analysis of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the Table and Figures in the ODCM, as well as summarized and tabulated results of these analyses and measurements in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979. In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted as soon as possible in a supplementary report.
The reports shall also include the following:
"* a summary description of the Radiological Environmental Monitoring Program;
" at least two legible maps covering all sampling locations keyed to a table giving distances and directions from the centerline of one reactor (one map shall cover stations near the site boundary; a second shall include the more distant stations);
"* the results of licensee participation in the Interlaboratory Comparison Program, required by SLC 16.11.15;
"* a discussion of all deviations from the sampling schedule of Table 16.11.13-1; and McGuire Units 1 and 2 16.11.16-1 Revision 1
Annual Radiological Environmental Operating Report 16.11.16 COMMITMENT (continued)
- a discussion of all analyses in which the LLD required by Table 16.11.13-3 was not achievable.
A single submittal may be made for a multiple unit station..
APPLICABILITY At all times.
REMEDIAL ACTIONS None TESTING REQUIREMENTS None BASES None REFERENCES
- 1. Technical Specification 5.6.2 McGuire Units 1 and 2 16.11.16-2 Revision 1
Radioactive Effluent Release Reports 16.11.17 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.17 Radioactive Effluent Release Reports COMMITMENT Routine Radioactive Effluent Release Reports covering the operation of the unit during the previous calendar year of operation shall be submitted before May 1 of each year.
The Radioactive Effluent Release Reports shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," Revision 1, June 1974, with data summarized on a quarterly basis following the format of Appendix B thereof.
The Radioactive Effluent Release Report shall include an annual summary of hourly meteorological data collected over the previous calendar year. This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability, and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability. This same report shall include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from the unit or station during the previous calendar year. This same report shall also include an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report period. All assumptions used in making these assessments, i.e., specific activity, exposure time and location, shall be included in these reports. A five year average of representative onsite meteorological data shall be used in the gaseous effluent dose pathway calculations. Dispersion factors (X/Qs) and deposition factors (D/Qs) shall be generated using the computer code XOQDOQ (NUREG/CR-2919) which implements NRC Regulatory Guide 1.111. The meteorological conditions concurrent with the time of release shall be reviewed annually to determine if the five-year average values should be revised. The assessment of radiation doses shall be performed in accordance with the methodology and parameters in the OFFSITE DOSE CALCULATION MANUAL (ODCM).
McGuire Units 1 and 2 16.11.17-1 Revision 1
Radioactive Effluent Release Reports 16.11.17 COMMITMENT (continued)
The Radioactive Effluent Release Report shall also include an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources, including doses from primary effluent pathways and direct radiation, for the previous calendar year to show conformance with 40 CFR Part 190, "Environmental Radiation Protection Standards for Nuclear Power Operation." Acceptable methods for calculating the dose contribution from liquid and gaseous effluents are given in Regulatory Guide 1.109, Rev. 1, October 1977.
The Radioactive Effluent Release Reports shall include the following information for each type of solid waste shipped offsite during the report period:
- a. Total container volume, in cubic meters,
- b. Total Curie quantity (determined by measurement or estimate),
- c. Principal radionuclides (determined by measurement or estimate),
- d. Type of waste (e.g., dewatered spent resin, compacted dry waste, evaporator bottoms),
- e. Number of shipments, and
- f. Solidification agent or absorbent (e.g., cement, or other approved agents (media)).
The Radioactive Effluent Release Reports shall include a list and description of unplanned releases from the site to UNRESTRICTED AREAS of radioactive materials in gaseous and liquid effluents made during the reporting period.
The Radioactive Effluent Release Reports shall include any changes made during the reporting period to the PROCESS CONTROL PROGRAM (PCP) and to the OFFSITE DOSE CALCULATION MANUAL (ODCM), as well as a listing of new locations for dose calculations and/or environmental monitoring identified by the land use census pursuant to SLC 16.11.14.
The Radioactive Effluent Release Reports shall also identify any licensee initiated major changes to the Radioactive Waste Systems (liquid, gaseous, and solid). Otherwise, this information may be included in the annual UFSAR update. The discussion of each change shall contain:
McGuire Units 1 and 2 16.11.17-2 Revision 1
Radioactive Effluent Release Reports 16.11.17 COMMITMENT (continued)
- a. A summary of the evaluation that led to the determination that the change could be made in accordance with 10 CFR Part 50.59;
- b. Sufficient detailed information to totally support the reason for the change without benefit of additional or supplemental information;
- c. A detailed description of the equipment, components, and processes involved and the interfaces with other plant systems;
- d. An evaluation of the change, which shows the predicted releases of radioactive materials in liquid and gaseous effluents and/or quantity of solid waste that differ from those previously predicted in the License application and amendments thereto;
- e. An evaluation of the change, which shows expected maximum exposures to individual in the UNRESTRICTED AREA and to the general population that differ from those previously estimated in the License application and amendments thereto;
- f. A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents and in solid waste, to the actual releases for the period prior to when the changes are to be made;
- g. An estimate of the exposure to plant operating personnel as a result of the change; and
- h. Documentation of the fact that the change was reviewed and found acceptable by the Station Manager or the Chemistry Manager.
A single submittal may be made for a multiple unit station. The submittal should combine those sections that are common to all units at the station; however, for units with separate Radwaste Systems, the submittal shall specify the releases of radioactive material from each unit.
APPLICABILITY At all times REMEDIAL ACTIONS None TESTING REQUIREMENTS None McGuire Units 1 and 2 16.11.17-3 Revision 1
Radioactive Effluent Release Reports 16.11.17 BASES None REFERENCES
- 1. Technical Specification 5.6.3 McGuire Units 1 and 2 16.11.17-4 Revision 1
Liquid Holdup Tanks 16.11.18 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.18 Liquid Holdup Tanks COMMITMENT The quantity of radioactive material contained in each unprotected outdoor radwaste tank shall be limited to < 10 Curies, excluding tritium and dissolved or entrained noble gases.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Quantity of radioactive A.1 Suspend all additions of Immediately material in tank not radioactive material to the within limit, tank.
AND A.2 Reduce the tank contents 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> to within limit.
AND A.3 Describe the events Within the next leading to this condition in scheduled Annual the next Annual Radioactive Effluent Radioactive Effluent Release Report Release Report.
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.18.1 Verify the quantity of radioactive material contained in 7 days unprotected outdoor radwaste tanks is within limits by analyzing a representative sample of the tank's contents when radioactive materials are being added to the tank.
McGuire Units 1 and 2 16.11.18-1 Revision 0
Liquid Holdup Tanks 16.11.18 BASES The tanks applicable to this SLC include all those outdoor radwaste tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents and that do not have tank overflows and surrounding area drains connected to the Liquid Radwaste Treatment System.
Restricting the quantity of radioactive material contained in the specified tanks provides assurance that in the event of an uncontrolled release of the tanks' contents, the resulting concentrations would be less than the limits of 10 CFR Part 20, Appendix B, Table II, Column 2, at the nearest potable water supply and the nearest surface water supply in an UNRESTRICTED AREA.
REFERENCES None McGuire Units 1 and 2 16.11.18-2 Revision 0
Explosive Gas Mixture 16.11.19 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.19 Explosive Gas Mixture COMMITMENT The concentration of oxygen in the WASTE GAS HOLDUP SYSTEM shall be limited to < 2% by volume whenever the hydrogen concentration exceeds 4% by volume.
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Concentration of oxygen A.1 Reduce oxygen 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> in the WASTE GAS concentration to within HOLDUP SYSTEM limits.
> 2% but < 4% by volume.
B. Concentration of oxygen B.1 Suspend all additions of Immediately in the WASTE GAS waste gases to the system.
HOLDUP SYSTEM
> 4% and hydrogen AND concentration > 4% by volume. B.2 Reduce the concentration Immediately of oxygen to < 4% by volume.
AND B.3 Reduce oxygen 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> concentration to within limits.
McGuire Units 1 and 2 16.11.19-1 Revision 0
Explosive Gas Mixture 16.11.19 TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.19.1 Verify the concentrations of hydrogen and oxygen in the During WASTE WASTE GAS HOLDUP SYSTEM is within limits by GAS HOLDUP monitoring waste gases in the WASTE GAS HOLDUP SYSTEM SYSTEM with the hydrogen and oxygen monitors operation required by SLC 16.7.8.
BASES This specification is provided to ensure that the concentration of potentially explosive gas mixtures contained in the WASTE GAS HOLDUP SYSTEM is maintained below the flammability limits of hydrogen and oxygen. Automatic control features are included in the system to prevent the hydrogen and oxygen concentrations from reaching these flammability limits. These automatic control features include isolation of the source of hydrogen and/or oxygen, automatic diversion to recombiners, or injection of dilutants to reduce the concentration below the flammability limits. Maintaining the concentration of hydrogen and oxygen below their flammability limits provides assurance that the releases of radioactive materials will be controlled in conformance with the requirements of General Design Criterion 60 of Appendix A to 10 CFR Part 50.
REFERENCES None McGuire Units 1 and 2 16.11.19-2 Revision 0
Gas Storage Tanks 16.11.20 16.11 RADIOLOGICAL EFFLUENT CONTROLS 16.11.20 Gas Storage Tanks COMMITMENT The quantity of radioactivity contained in each gas storage tank shall be limited < 49,000 Curies noble gases (considered as Xe-1 33).
APPLICABILITY At all times.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Quantity of radioactive A.1 Suspend all additions of Immediately material in tank not radioactive material to the within limit, tank.
AND A.2 Reduce the tank contents 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> to within limit.
TESTING REQUIREMENTS TEST FREQUENCY TR 16.11.20.1 Verify the quantity of radioactive material contained in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> each gas storage tank is within limit when radioactive materials are being added to the tank.
McGuire Units 1 and 2 16.11.20-1 Revision 0
Gas Storage Tanks 16.11.20 BASES This SLC considers postulated radioactive releases due to a waste gas system leak or failure, and limits the quantity of radioactivity in each pressurized gas storage tank in the WASTE GAS HOLDUP SYSTEM to assure that a release would be substantially below the dose guideline values of 10 CFR Part 100 for a postulated event.
Restricting the quantity of radioactivity contained in each gas storage tank provides assurance that in the event of an uncontrolled release of the tank's contents, the resulting total body exposure to a MEMBER OF THE PUBLIC at the nearest exclusion area boundary will not exceed 0.5 rem. This is consistent with Standard Review Plan 11.3, Branch Technical Position ETSB 11-5, "Postulated Radioactive Releases Due to a Waste Gas System Leak or Failure," in NUREG-0800, July 1981.
REFERENCES None McGuire Units 1 and 2 16.11.20-2 Revision 0