IR 05000261/2011004
| ML113180464 | |
| Person / Time | |
|---|---|
| Site: | Robinson (DPR-023) |
| Issue date: | 11/14/2011 |
| From: | Randy Musser NRC/RGN-II/DRP/RPB4 |
| To: | William Gideon Carolina Power & Light Co |
| References | |
| IR-11-004, IR-11-502 | |
| Download: ML113180464 (35) | |
Text
November 14, 2011
SUBJECT:
H.B. ROBINSON STEAM ELECTRIC PLANT - NRC INTEGRATED INSPECTION REPORT 05000261/2011004, 05000261/2011502, AND ASSESSMENT FOLLOW-UP LETTER
Dear Mr. Gideon:
On September 30, 2011, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your H.B. Robinson reactor facility. The enclosed integrated inspection report documents the inspection results, which were discussed on November 14, with Mr. Thomas Cosgrove and other members of your staff.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.
The report documents one self-revealing apparent violation (AV) that has potential safety significance greater than very low safety significance. The significance of this finding is designated as To Be Determined (TBD) until the safety characterization has been completed.
This finding is associated with the failure to consider how the aggregate changes to the sites topography could impact the sites ability to drain storm water runoff and adequately respond to localized flooding during periods of heavy rain. However, the plant has taken appropriate interim corrective actions such that the finding does not present an immediate safety concern.
Immediate actions taken by your staff included the removal of the water from the affected plant buildings and grounds. In addition, within a few weeks of the event, the licensee repaired the washed out area of the berm just to the north of the power block, and performed interim adjustments to site topography to limit ponding near the berm.
In addition, the report documents one NRC-identified finding of very low safety significance (Green). The finding was determined to involve a violation of NRC requirements. However, because of the very low safety significance and because it is entered into your corrective action program, the NRC is treating this finding as non-cited violation (NCV) consistent with Section 2.3.2 of the NRC Enforcement Policy. If you contest this NCV, you should provide a response
within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident Inspector at the H.B. Robinson facility.
On June 9, 2011, the NRC conducted an exit for the IP 95002 supplemental inspection which was conducted for the three White findings, which placed H.B. Robinson Unit 2 in the Degraded Cornerstone Column in the third quarter of 2010, as discussed in the assessment letter dated March 4, 2011. On July 6, 2011, the NRC issued the supplemental inspection report (IR 5000261/2011010, ML # 111870510), which documented that you adequately addressed the three White findings. As stated in the supplemental inspection report, one finding, specifically 05000261/2010013-01, Failure to Comply with Conduct of Operations Procedure, would still be considered for agency actions in accordance with the Action Matrix until September 30, 2011.
The NRC determined that as of October 1, 2011, the performance at H.B. Robinson Unit 2 is in the Licensee Response Column of the Reactor Oversight Process Action Matrix. Although plant performance is now considered to be within the Licensee Response Column, the NRC has not yet finalized the significance of apparent violation AV 05000261/2011004-01, Water Intrusion into Safety-Related Buildings due to Inadequate Design of Site Storm Water Runoff Drainage System. The final safety significance determination of this issue may change our assessment of the performance at H.B. Robinson Unit 2.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Randall A. Musser, Chief Reactor Projects Branch 4 Division of Reactor Projects
Docket No.:
50-261 License No.: DPR-23
Enclosure:
Inspection Report 05000261/2011004, 05000261/2011502 w/Attachment: Supplemental Information
REGION II==
Docket No:
50-261 License No:
DPR-23 Report No:
005000261/2011004, 05000261/2011502 Facility:
H. B. Robinson Steam Electric Plant, Unit 2 Location:
3581 West Entrance Road Hartsville, SC 29550
Dates:
July 1, 2011 through September 30, 2011 Inspectors:
J. Hickey, Senior Resident Inspector T. Chandler, Acting Senior Resident Inspector C. Scott, Resident Inspector E. Coffman, Resident Inspector, V.C. Summer M. Coursey, Reactor Inspector C. Stancil, Resident Inspector, Browns Ferry J. Austin, Senior Resident Inspector, Harris
Approved by:
R. Musser, Chief Reactor Projects Branch 4 Division of Reactor Projects
Enclosure
SUMMARY OF FINDINGS
IR 05000261/2011004, 05000261/2011502, 07/01/2011 - 09/30/2011; H.B. Robinson Steam
Electric Plant, Unit 2; Adverse Weather Protection and Operability Evaluations.
The report covered a three month period of inspection by several resident inspectors and one reactor inspector. One AV and one NCV were identified. The significance of most findings is indicated by their color (Green, White, Yellow, Red) using Inspection Manual Chapter (IMC)0609, Significance Determination Process (SDP). The cross-cutting aspects were determined using IMC 0310, Components within the Cross-Cutting Areas. Findings for which the SDP does not apply may be Green or be assigned a severity level after NRC management review.
NRC-Identified and Self-Revealing Findings
Cornerstone: Initiating Events
- TBD. A self-revealing apparent violation (AV) of 10 CFR 50, Appendix B, Criterion III,
Design Control, was identified for the licensees failure to consider how the aggregate changes to the sites topography could impact the sites ability to drain storm water runoff and adequately respond to localized flooding during periods of heavy rain. This resulted in the ponding of storm water runoff, the subsequent direction of runoff flow towards the power block, overfilling of the retention basin, backup of the storm drainage system, and ultimately, uncontrolled water intrusion into safety-related equipment rooms in the auxiliary building. The licensee took immediate actions to remove the water from the affected plant buildings and grounds. In addition, within a few weeks of the event, the licensee repaired the washed out area of the berm just to the north of the power block, and performed interim adjustments to site topography to limit ponding near the berm. The licensee plans to perform additional site grade and trench restoration and remediation to permanently prevent site ponding. This issue was entered into the licensees corrective action program as NCR 468235.
The licensees failure to consider how the aggregate changes to the sites topography could impact the sites ability to drain storm water runoff and adequately respond to localized flooding during periods of heavy rain as required by procedure EGR-NGGC-0005, Engineering Change, was a performance deficiency. This performance deficiency was considered more than minor because it was associated with the Initiating Events Cornerstone attributes of the Design Control (plant modifications) and Protection Against External Factors (flood hazard), and adversely affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Specifically, the failure to consider aggregate changes to the sites topography on the sites ability to drain storm water runoff resulted in uncontrolled water intrusion into safety-related equipment rooms. The inspectors assessed the finding using Inspection Manual Chapter (IMC) 0609, Significance Determination Process (SDP), Att. 4, Phase 1 - Initial Screening and Characterization of Findings, and determined the finding was potentially greater than very low safety significance because the finding increases the likelihood of an external flooding event. As a result, the characterization worksheet for Initiating Events required a Phase 3 analysis using the Individual Plant Examination for External
Event Submittal (IPEEE) or other existing plant specific analyses as inputs. The significance of this finding is designated as To Be Determined (TBD) until the safety characterization has been completed by the NRC Senior Reactor Analyst (SRA). The inspectors determined that the cause of this finding was related to the trending and assessment aspect in the Corrective Action Program component of the Problem Identification and Resolution cross-cutting area. (P.1(b)) (Section 1R01)
Cornerstone: Mitigating Systems
- Green.
The inspectors identified a Green NCV of Technical Specification (TS) 5.4.1,
Administrative Controls, Procedures, for failure to establish procedural guidance to monitor Service Water System (SWS) parameters and operate the SWS strainers following a loss of offsite power (LOOP). Following a LOOP, the operators ability to recover from a plugged SWS strainer would be impacted due to the loss of the associated control alarm and the lack of procedural guidance to manually operate the SWS strainers. The licensee has revised plant procedures to include additional instructions that will ensure that operators can recover from plugged SWS strainers and preserve the operation of the SWS following a LOOP. This issue was entered into the licensees corrective action program as NCR 473900.
The failure to establish procedural guidance to locally monitor SWS parameters and manually operate the SWS strainers following a LOOP was a performance deficiency.
This issue was more than minor because if left uncorrected this finding would have the potential to lead to a more significant safety concern. Specifically, the inability to clean the service water strainers, following a prolonged LOOP, could impact the operation of the service water system. The SDP Phase 1 screening determined that this finding was within the mitigating systems cornerstone and was potentially risk significant due to a seismic, flooding or severe weather initiating event and therefore required a Phase 3 SDP analysis. An NRC Senior Reactor Analyst (SRA) determined the lack of procedure for a loss of the service water strainers due to an external event (i.e., loss of offsite power removing power to the strainers and causing debris to clog the system) was of very low risk significance i.e.,
- Green.
The main contributors to the low risk results were:
1) the low likelihood of a total loss of service water event, and 2) the probability of recovery of the strainers and/or the system despite the lack of procedures. The inspectors determined that the finding has a cross-cutting aspect in the Corrective Action Program component of the Problem Identification and Resolution area, because the licensee failed to thoroughly evaluate the issue such that the resolution addressed the cause and extent of conditions, as necessary. Specifically, licensees evaluation of the NCR associated with the lack of plant procedures to manually operate the SWS, failed to recognize that the control room indication associated with a plugged SWS strainer would be lost following a LOOP. (P.1(c)) (Section 1R15)
Licensee-Identified Violations
None
REPORT DETAILS
Summary of Plant Status: The unit began the inspection period at rated thermal power. On July 22 a power reduction to 50 percent was initiated for planned maintenance. The unit was returned to rated thermal power on July 25, 2011. On August 2 power management actions began in order to control circulating water discharge temperature into Lake Robinson. These actions resulted in power being cycled by as much as 20 percent and continued until August 15.
The unit operated at full power until September 26 when it tripped due to a failed relay in the C Reactor Coolant Pump (RCP) breaker. Startup of the unit was initiated on September 29 and rated thermal power was attained on October
REACTOR SAFETY
Cornerstones: Initiating Events, Mitigating Systems, Barrier Integrity
==1R01 Adverse Weather Protection
==
.1 External Flooding
(Closed) URI 05000261/2011003-1, Rainstorm Results in Flooding of the Power Block
a. Inspection Scope
The inspectors previously opened URI 05000261/2011003-01, Rainstorm Results in Flooding of the Power Block, in NRC Integrated Inspection Report 05000261/2011003.
The inspectors performed a review of the Updated Final Safety Analysis Report (UFSAR), the IPEEE, the root cause evaluation report for NCR 468235, and calculation RNP-F/PSA-0009, Assessment of Internally Initiated Flood Events.
b. Findings
Introduction.
A self-revealing apparent violation (AV) of 10 CFR 50, Appendix B, Criterion III, Design Control, was identified for the licensees failure to consider how the aggregate changes to the sites topography could impact the sites ability to drain storm water runoff and adequately respond to localized flooding during periods of heavy rain.
This performance deficiency resulted in the ponding of storm water runoff, the subsequent direction of runoff flow towards the power block, overfilling of the retention basin, backup of the storm drainage system, and ultimately, uncontrolled water intrusion into safety-related equipment rooms in the auxiliary building. The licensee took immediate actions to remove the water from the affected plant buildings and grounds. In addition, within a few weeks of the event, the licensee repaired the washed out area of the berm just to the north of the power block, and performed interim adjustments to site topography to limit ponding near the berm. The licensee plans to perform additional site grade and trench restoration and remediation to permanently prevent site ponding. This issue was entered into the licensees corrective action program as NCR 468235.
Description.
The UFSAR for the H.B. Robinson Plant states: Flooding is a physical impossibility at this site since the maximum cooling lake level which can be maintained by the drain and appurtenant structures is below plant grade. The IPEEE for the plant states that due to the sites topography, the probability of a sustained water level of one foot or more at the Auxiliary Building following the probable maximum precipitation (30 inches in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> - NOAA 1978) is extremely unlikely. On May 27, 2011, the Robinson Nuclear Plant experienced a heavy rainstorm that resulted in uncontrolled water intrusion into several safety-related equipment rooms due to external flooding. This storm produced only 3.71 inches of rain in one 6-hour period, which is only 12 percent of that assumed in the IPEEE.
The heavy rains caused localized ponding of storm water runoff in the protected area (PA) and outlying areas of the owner controlled area. From approximately 1200 on May 27, 2011, to 0200 on May 28, 2011, the plant received a total of 5.82 inches of rain, with 3.71 inches being received in the first 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. This initial influx of rain water exceeded the capacity of the existing storm drain system, and as a result, storm water backed up into plant buildings, including the A train emergency diesel generator (EDG) room. The floor drains in the EDG rooms, which are tied directly to the storm drain system, had been modified in 1994 to add back-flow isolation valves to prevent such an event.
However the back-flow isolation valve in the A EDG room failed to close.
Within the first 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, storm water runoff from the areas north of the plant, which include the Independent Spent Fuel Storage Installation (24P-ISFSI) pad, the Unit 1 landfill, and the Unit 1 coal pile, began to form a large pond on the north side of the berm which runs along the protected area (PA) fence on the north side of the plant. At approximately 1515 on May 27 the first washout of soil occurred from the berm area south of the ISFSI pad. The washed out soil collected in the storm drains and storm drain catch basins on the north side of the plant rendering them inoperable. As a result, several of the buildings on the north side of the power block were flooded with several inches of water.
At 1530, another larger washout of the same berm occurred in the southeast corner of the 24P-ISFSI pad allowing additional amounts of soil and storm water runoff to drain into the north side of the PA. This second washout effectively drained the large pond north of the berm. Soon after, a third washout occurred in the southwest corner of the 24P-ISFSI pad.
By 1800, the licensee had removed enough soil from the north side of the plant to allow the 6-8 inches of water that had accumulated up against the power block to drain to the retention ponds. This draining of the north plant area eventually overflowed both the Unit 1 (coal plant) and Unit 2 retention basins which had been cross-connected earlier in an attempt to prevent Unit 2 retention basin from overflowing.
It should be noted that none of the Auxiliary Building internal or external doors are designed to be watertight, and as a result, water flowed under and around the external doors on the north and east sides of the building for several hours. However, the Auxiliary Building sump system minimized the effects of the water ingress until the sump pumps had to be secured due to high level in the Waste Hold Up Tank. The water level in the Safety Injection and Containment Spray pump room, which is located against the north wall of the Auxiliary Building, reached 1-2 inches in depth. Many rooms inside the Auxiliary Building, including the A EDG room and the hallway that contains one of the two safety-related 480 volt ac motor control centers, had 1-2 inches of water on the floor. The Hot Machine Shop and New Fuel Storage Room, which are located on the north side of the power block, contained 6-8 inches of standing water.
Within a few hours, the licensee had removed the water from the affected plant buildings and grounds. In addition, within a few weeks of the event the licensee repaired the washed out area of the berm and performed interim adjustments to site topography to limit ponding near the berm. The licensee plans to perform additional site grade and trench restoration and remediation to permanently prevent site ponding. The licensee also initiated revisions to procedures to provide adequate guidance for slope and berm backfill, coordinate site topography changes between Units 1 and 2, and to require erosion control plans for parking areas, roadways, and drives.
The modifications to the sites topography that led to the May 27, 2011, external flooding event occurred over several decades, but culminated with the capping of the Unit 2 landfill in April 2010. During the summer of 2010 there were three separate rain events that caused breaches through the berm on the north side of the PA due to ponding of storm water runoff. Therefore it can be conservatively assumed that the site was vulnerable to external flooding events for approximately 13 months before the May 27 event.
Although no safety-related equipment was directly impacted during the May 27 event, there were 1-2 inches of water in several rooms that contain significant amounts of safety-related equipment. The majority of the safety-related equipment is mounted approximately 12 inches above the floor. However, the rain storm on May 27 produced only 3.71 inches of rain in one 6-hour period, which is only 12 percent of that assumed in the IPEEE. Had the site received the probable maximum precipitation, the likelihood of safety related equipment being impacted by raising flood water would have increased.
Analysis.
The licensees failure to consider how the aggregate changes to the sites topography could impact the sites ability to drain storm water runoff and adequately respond to localized flooding during periods of heavy rain as required by procedure EGR-NGGC-0005, Engineering Change, was a performance deficiency. Specifically, the licensee did not follow procedure EGR-NGGC-0005, Engineering Change, which provides guidance and checklist items to ensure that the aggregate effects of facility changes on rain water runoff were considered. This performance deficiency was considered more than minor because it was associated with the Initiating Events Cornerstone attributes of the Design Control (plant modifications) and Protection Against External Factors (flood hazard), and adversely affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Specifically, the failure to consider aggregate changes to the sites topography on the sites ability to drain storm water runoff resulted in uncontrolled water intrusion into safety-related equipment rooms.
The inspectors assessed the finding using Inspection Manual Chapter (IMC) 0609, Significance Determination Process (SDP), Att. 4, Phase 1 - Initial Screening and Characterization of Findings, and determined the finding was potentially greater than very low safety significance because the finding increases the likelihood of an external flooding event. As a result, the characterization worksheet for Initiating Events required a Phase 3 analysis using the IPEEE or other existing plant specific analyses as inputs.
The significance of this finding is designated as To Be Determined (TBD) until the safety characterization has been completed.
The inspectors determined that the cause of this finding was related to the trending and assessment aspect in the Corrective Action Program component of the Problem Identification and Resolution cross-cutting area. Specifically, the licensee used less-than-adequate trending and assessment techniques and thus failed to recognize a significant number of event pre-cursors that indicated an adverse trend in the sites ability to control storm water runoff. P.1(b)
Enforcement.
10 CFR 50, Appendix B, Criterion III requires in part that the design basis is correctly translated into drawings and procedures, and the adequacy of design changes are verified or checked. Site procedure EGR-NGGC-0005, Engineering Change, is used to implement this regulatory requirement. Contrary to the above, from November 1966 to April 2010 the licensee made several modifications to the sites topography without performing adequate design reviews that would have identified the aggregate effects of the proposed topography changes on storm water runoff. This resulted in the May 27, 2011, uncontrolled water intrusion into safety-related equipment rooms. This issue was entered into the licensees corrective action program as NCR 468235. The licensee has initiated the following corrective actions to restore compliance:
- Implement an Engineering Change to restore grading and trenching to ensure storm runoff in the north plant area is directed to appropriate drains
- Perform necessary design basis calculations to support compliance with 10 CFR 50, Appendix A, Criterion 2, Design bases for protection against natural phenomena
- Revise the interface agreement between Unit 1 and Unit 2 to coordinate changes to the sites topography controlled by Unit 1 to ensure review by Unit 2 engineering for impact to design, licensing, and regulatory requirements
- Revise the sites design change procedures to require a sedimentation and erosion control plan when the potential for runoff of disturbed land exists
Pending determination of safety significance, this finding is identified as an apparent violation (AV)05000261/2011004-01, Water Intrusion into Safety-Related Buildings due to Inadequate Design of Site Storm Water Runoff Drainage System.
URI 05000261/2011003-01, Rainstorm Results in Flooding of the Power Block is closed.
==1R04 Equipment Alignment
a. Inspection Scope
Partial System Walkdowns:
==
The inspectors performed the following three partial system walkdowns, while the indicated structures, systems, and/or components (SSCs) were out-of-service for maintenance and testing:
'B' motor-driven auxiliary feed water (AFW) pump while 'A' pump was out of service for planned maintenance
- A Instrument Air System while B Instrument Air Compressor was out of service for corrective maintenance
- A, B, and C safety injection (SI) pumps after the B and C SI pumps were swapped following a test of the B SI pump
To evaluate the operability of the selected trains or systems under these conditions, the inspectors compared observed positions of valves, switches, and electrical power breakers to the procedures and drawings listed in the Attachment.
The inspectors reviewed the following ARs associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 477699, Moisture Separator Reheat Purge Valves Found Closed During Normal Plant Operation
- 480007, Clearance Information Tags Hung on Wrong Components
b. Findings
No findings were identified.
==1R05 Fire Protection
==
.1 Quarterly Resident Inspector Tours
a. Inspection Scope
For the five areas identified below, the inspectors reviewed the control of transient combustible material and ignition sources, fire detection and suppression capabilities, fire barriers, and any related compensatory measures to verify that those items were consistent with Updated Final Safety Analysis Report (UFSAR) Section 9.5.1, Fire Protection System, and UFSAR Appendix 9.5.A, Fire Hazards
Analysis.
The inspectors walked down accessible portions of each area and reviewed results from related surveillance tests to verify that conditions in these areas were consistent with descriptions of the areas in the UFSAR. Documents reviewed are listed in the
.
The following areas were inspected:
- Turbine Building Ground Level (fire zones 25 A&B)
- Turbine Building Mezzanine Level (fire zones 25 E&F)
'A' and 'B' Battery Room (fire zone 16)
- Safety Injection Pump Room (fire zone 3)
- Component Cooling Water Pump Room (fire zone 5)
The inspectors reviewed the following AR associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 486287, Engine Driven Fire Pump Heaters Not Working
b. Findings
No findings were identified.
.2 Annual Fire Protection Drill Observation
a. Inspection Scope
To evaluate the readiness of personnel to prevent and fight fires, the inspectors observed fire brigade performance during the announced fire drill in the condensate polishing building motor-control center on September 7. This included observing the pre-drill briefing for the drill controllers, dress out of the fire brigade members in the fire locker, fire brigade performance at the fire scene, and the post-drill critiques for the controllers and the fire brigade. The inspectors evaluated the fire brigade performance to verify that they responded to the fire in a timely manner, donned proper protective clothing, used self-contained breathing apparatus, and had the equipment necessary to control and extinguish the fire. The inspectors also assessed the adequacy of the fire brigades fire fighting strategy including entry into the fire area, communications, search and rescue, and equipment usage.
b. Findings
No findings were identified.
==1R06 Flood Protection Measures
a. Inspection Scope
==
The inspectors walked down the SI pump room and the A emergency diesel generator (EDG) room to verify that each area configuration, features, and equipment functions were consistent with the descriptions and assumptions used in Calculation RNP-F/PSA-0009, Assessment of Internally Initiated Flood Events. Specifically, motor controllers and terminal boxes that could become potentially submerged were inspected to ensure that the sealing gasket material was intact and undamaged. Those rooms were selected because they contain risk-significant SSCs which are susceptible to flooding from postulated pipe breaks. The inspectors also reviewed the operator actions credited in the analysis to verify that the desired results could be achieved using the plant procedures listed in the Attachment.
The inspectors reviewed the following ARs associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 482434, Potential Adverse Trend in Rainwater Intrusion
- 476676, Water Present In Manholes M-35 and M-36
b. Findings
No findings were identified.
==1R11 Licensed Operator Requalification
a. Inspection Scope
==
The inspectors observed licensed-operator performance during requalification simulator training to verify that operator performance was consistent with expected operator performance, as described in Exercise Guide LOCT 03-4. This training tested the operators ability to operate components from the control room, direct auxiliary operator actions, and determine the appropriate emergency action level classifications while responding to a turbine first stage pressure transmitter failure, manual control of steam generator levels, a rod control urgent failure alarm, inadvertent turbine trip/reactor trip and a loss of the E-2 safety bus with a failure of the B EDG output breaker to close.
The inspectors focused on clarity and formality of communication, the use of procedures, alarm response, control board manipulations, group dynamics, and supervisory oversight.
The inspectors also observed the simulator exercise freeze critiques to verify that the licensee identified deficiencies and discrepancies that occurred during the simulator training.
b. Findings
No findings were identified.
==1R12 Maintenance Effectiveness
a. Inspection Scope
==
The inspectors reviewed the three degraded SSC/function performance problems or conditions listed below to verify the appropriate handling of these performance problems or conditions in accordance with 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, and 10 CFR 50.65, Maintenance Rule. Documents reviewed are listed in the
.
The problems/conditions and their corresponding ARs were:
- 474815, C Charging Pump Flow in the Alert Range
- 478069, Right Turbine Stop Valve Did Not Go Completely Closed During Testing
- Overall Performance History of the Dedicated Shutdown Diesel System
During the reviews, the inspectors focused on the following:
- Appropriate work practices,
- Identifying and addressing common cause failures,
- Scoping in accordance with 10 CFR 50.65(b),
- Characterizing reliability issues (performance),
- Charging unavailability (performance),
- Trending key parameters (condition monitoring),
- 10 CFR 50.65(a)(1) or (a)(2) classification and reclassification, and
- Appropriateness of performance criteria for SSCs/functions classified (a)(2) and/or appropriateness and adequacy of goals and corrective actions for SSCs/functions classified (a)(1).
The inspectors reviewed the following ARs associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 434642, Iso-Phase Bus Loss of Cooling Alarms Spuriously
- 434646, Steam Generator Feedwater Regulating Valves are Moving in a Jerking Motion
b. Findings
No findings were identified.
==1R13 Maintenance Risk Assessments and Emergent Work Evaluation
a. Inspection Scope
==
For the six samples listed below, the inspectors reviewed risk assessments and related activities to verify that the licensee performed adequate risk assessments and implemented appropriate risk-management actions when required by 10 CFR 50.65(a)(4). For emergent work, the inspectors also verified that any increase in risk was promptly assessed, and that appropriate risk-management actions were promptly implemented. Documents reviewed are listed in the Attachment. Those periods included the following:
- July 1, 2011, Emergent work to repair the A and B Charging pump following failure of the B Speed Controller and High Stuffing Box Temperature on A Charging Pump
- July 4-11, 2011, Work week included B Charging Pump maintenance, calibration of the Refueling Water Storage Tank (RWST) Level Transmitter LT-948, and A Instrument Air Compressor maintenance.
- July 11-17, 2011, Work week included V2-16C AFW Isolation Valve control switch replacement, clean and test the B AFW Pump Oil Cooler, and inspection and vibration monitoring of containment cooling fans
- July 25-31, 2011, Work week included B SI Pump stud inspection, SI room cooling fan HVH-6A inspection, and testing of the A Containment Spray (CS) Pump
- August 1-7, 2011, Work week included an unplanned down-power to maintain water discharge temperatures, reactor coolant pump seal injection flow transmitter calibrations, and C Charging Pump scoop tube adjustment
- September 12-19, 2011, Work week included modifications to the Dedicated Shutdown Diesel Generator and associated load center, and reactor protection system train B logic testing.
The inspectors reviewed the following ARs associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 479209, Several PM Frequencies do not Align with Train Separation
- 476370, B MDAFW Pump Scheduled Unavailability Time Exceeded
b. Findings
No findings were identified.
==1R15 Operability Evaluations
a. Inspection Scope
==
The inspectors reviewed the four operability determinations associated with the ARs listed below. The inspectors assessed the accuracy of the evaluations, the use and control of any necessary compensatory measures, and compliance with the TS. The inspectors verified that the operability determinations were made as specified by Procedure OPS-NGGC-1305, Operability Determinations. The inspectors compared the justifications provided in the determinations to the requirements from the TS, the UFSAR, and associated design-basis documents to verify that operability was properly justified and the subject components or systems remained available, such that no unrecognized increase in risk occurred:
- 474425, B Charging Pump Speed Control Failed High
- 485071, A train SI Accumulator leaking
- 463149, Manual Operation of the Service Water Header Strainers
- 463429, Small Service Water Leak at SW-56 (Station Air Compressor Outlet to Aftercooler)
Documents reviewed are listed in the Attachment.
The inspectors reviewed the following ARs associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 482618, MCC-6(10F)-42/C Pick Up Voltage Greater Than Procedure Threshold
- 483178, Inadequate Heat Removal During Station Battery Capacity Test
b. Findings
Introduction:
The inspectors identified a green NCV of Technical Specification 5.4.1, Administrative Controls, Procedures, for the licensees failure to establish adequate procedural guidance to monitor SWS parameters and operate the SWS strainers following a loss of offsite power (LOOP).
Description:
On May 4, 2011, site engineering wrote a condition report, NCR 463149, which identified that plant procedures did not include instructions to manually clean the SWS strainers following a LOOP. The NCR noted that the SWS design bases document validation report identified that the periodic cleaning of the SWS strainers had to be performed using manual operator action following a LOOP. The vendor technical manual outlines the procedure for the manual operation of the strainer. However, current licensee procedures did not include instructions for operators to manually operate the SWS strainers following a LOOP. The licensee initiated actions to update current licensee procedures to include guidance to manually clean the strainers and closed the associated condition report on May 10, 2011.
The inspectors reviewed NCR 463149 and the actions associated with its closure. The SWS strainers are designed to strain debris from Lake Robinson and support the operation of the SWS. The SWS strainers include a motor, wiper, timer and control switches which are all powered via, MCC-7, a non-safety related source. The wipers have a self-cleaning feature which will automatically start on a high differential pressure signal across the strainers. The high differential pressure sensed across the strainers would also actuate an alarm in the control room. The inspectors reviewed the annunciator response procedure, AP-008, SW Strainer Hi DP, and questioned whether the instrumentation required to alert the control room operators was powered from the same non-safety related power source as the strainers. The licensee reviewed the inspectors concern and determined that the control room alarm associated with the SW strainers was also powered by MCC-7. The inspectors were concerned that an external event, such as a tornado or hurricane, coincident with a LOOP, may challenge the operation of the SWS, due to the lack of control room indication of a plugged strainer.
The inspectors concluded that, without indication, control room operators would be unable to identify the need to take the appropriate actions to manually clean the strainer prior to a significant loss of SWS flow. The licensee documented this issue in NCR 473900 and initiated actions to change plant procedures to include guidance to locally monitor SWS parameters and manually clean the strainers following a LOOP.
Analysis:
The failure to establish adequate procedural guidance to monitor SWS parameters and manually operate the SWS strainers following a LOOP was a performance deficiency. The finding was more than minor because if left uncorrected, the performance deficiency has the potential to lead to a more significant safety concern.
Specifically, the failure to clean the service water strainers, following a LOOP, could impact the operation of the service water system. A Significance Determination Process (SDP) Phase 1 screening was performed and determined that this finding was within the mitigating systems cornerstone and potentially risk significant due to a seismic, flooding or severe weather initiating event. Consequently a Phase 3 analysis was required. Two dominant core damage sequences were evaluated. The first dominant accident sequence consisted of a reactor trip, initiated by a loss of condenser heat sink, and a subsequent failure to initiate high pressure recirculation, which leads to a RCP seal loss of coolant accident. The second dominant accident sequence consisted of a LOOP followed by the failure of the turbine-driven AFW pump and non-recovery of the electrical system. A senior reactor analyst determined that the lack of a procedure for a loss of the service water strainers due to an external event (i.e., loss of offsite power removing power to the strainers and causing debris to clog the system) was of very low risk significance i.e., Green. The main contributors to the low risk results were: 1) the low likelihood of a total loss of service water event, and 2) the probability of recovery of the strainers and/or the system despite the lack of procedures.
The inspectors determined that the finding has a cross-cutting aspect in the Corrective Action Program component of the Problem Identification and Resolution area, because the licensee failed to thoroughly evaluate the issue such that the resolution addressed the cause and extent of conditions, as necessary. Specifically, licensees evaluation of the NCR associated with the lack of plant procedures to manually operate the SWS, failed to recognize that the control room indication associated with a plugged SWS strainer would be lost following a LOOP. (P.1(c))
Enforcement:
TS 5.4.1, Administrative Control, Procedures, requires that written procedures shall be established, implemented, and maintained, covering applicable procedures recommended in Regulatory Guide 1.33, Appendix A, February 1978.
Section 3 of Regulatory Guide 1.33, Appendix A, February 1978 states that operation of systems that affect the safety of the nuclear power plant, including the service water system, should be conducted in accordance with written procedures. The licensee established, OP-903, Service Water System, as the governing procedure for operation of the Service Water System. Contrary to the above, on May 4, 2011, it was identified that the licensees procedure, OP-903, failed to provide adequate guidance for the operation of the SWS strainers following a LOOP. The licensee revised the plant procedure to include guidance to locally monitor SWS parameters and manually clean the strainers following a LOOP. Because this violation was of very low safety significance and it was entered into the licensees corrective action program (AR 473900473900, this violation is being treated as a non-cited violation (NCV), consistent with the NRC Enforcement Policy.
This violation is therefore designated as NCV 05000261/2011004-02, Failure to Establish Guidance to Monitor and Operate Service Water Strainers Following LOOP.
==1R18 Plant Modifications
==
.1 Permanent Modification
a. Inspection Scope
The inspectors reviewed the permanent modification described in Engineering Change 81014, C Charging Pump Oil Level Sightglass Installation, to verify that the modification design, implementation, and testing did not degrade the design basis, and performance capabilities of risk significant equipment and did not place the plant in an unsafe or unanalyzed condition. The inspectors verified that the modification satisfied the requirements of Procedure EGR-NGGC-005, Engineering Change, and 10 CFR 50, Appendix B, Criterion III, Design Control. Documents reviewed are listed in the
.
b. Findings
No findings were identified.
==1R19 Post Maintenance Testing
a. Inspection Scope
==
For the seven post-maintenance tests (PMT) listed below, the inspectors witnessed the test and/or reviewed the test data to verify that test results adequately demonstrated restoration of the affected safety functions described in the UFSAR and TS. Documents reviewed are listed in the Attachment.
The following tests were witnessed/reviewed:
- WO 1496981, Replace CVC-2080, C Charging Pump Suction Relief Valve, PMT in accordance with PLP-111, Leak Reduction Program, Rev. 14
- WO 1659779, 230 kV Auxiliary Relay Inspection, PMT in accordance with WO 1659779
- WO 1528300, Replace GEMCO Switch on Auxiliary Feedwater Header Discharge to Steam Generator C, PMT in accordance with OST-201-2, Motor Driven Auxiliary Feedwater System Component Test-Train B, Rev. 29
- WO 1957584, Replacement of Control Rod Position Indicator P-10 Module, PMT in accordance with WO 1957584
- WO 1739819, A Safety Injection Pump Bearing Cooler Cleaning, PMT in accordance with OST-151-1, Safety Injection System Components Test - Pump A, Rev. 34
- WO 1686830, Installation of Auto-Start Circuitry Per EC 69423, PMT in accordance with SP-1540, Dedicated Shutdown Diesel Generator Auto Start Functional Test, Rev. 3
- WO 1620791, SI Pump B Line and Thrust Bearing Oil Reservoir Repairs, PMT in accordance with procedures OST-151-1, Comprehensive Flow Test for Safety Injection Pump B, Rev. 17, and OST-155, Safety Injection System Integrity Test, Rev. 32
The inspectors reviewed the following ARs associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 479781, Inadequate PMT Following EC Installation
b. Findings
No findings were identified.
1R20 Refueling and Outage Activities
For the outage that began on September 26 and ended on September 30, the inspectors evaluated licensee outage activities as described below to verify that the licensee considered risk in developing outage schedules, adhered to administrative risk reduction methodologies they developed to control plant configuration, and adhered to operating license and technical specification requirements that maintained defense-in-depth. The inspectors also verified that the licensee developed mitigation strategies for losses of the following key safety functions:
- inventory control
- power availability
- reactivity control
- containment
Documents reviewed are listed in the Attachment.
.1 Review of Outage Plan
a. Inspection Scope
The inspectors reviewed the outage risk control plan to verify that the licensee had performed adequate risk assessments, and had implemented appropriate risk-management strategies when required by 10 CFR 50.65(a)(4).
b. Findings
No findings were identified.
.2 Licensee Control of Outage Activities
a. Inspection Scope
During the outage, the inspectors observed the items or activities described below to verify that the licensee maintained defense-in-depth commensurate with the outage risk-control plan for key safety functions and applicable technical specifications when taking equipment out of service.
- Clearance Activities
- Electrical Power
- Reactivity Control
- Fatigue Management
The inspectors also reviewed responses to emergent work and unexpected conditions to verify that resulting configuration changes were controlled in accordance with the outage risk control plan, and to verify that control-room operators were kept cognizant of the plant configuration.
b. Findings
No findings were identified.
.3 Monitoring of Heatup and Startup Activities
a. Inspection Scope
Prior to mode changes and on a sampling basis, the inspectors reviewed system lineups and/or control board indications to verify that TSs, license conditions, and other requirements, commitments, and administrative procedure prerequisites for mode changes were met prior to changing modes or plant configurations. Also, the inspectors periodically reviewed reactor coolant system (RCS) boundary leakage data, and observed the setting of containment integrity to verify that the RCS and containment boundaries were in place and had integrity when necessary. The inspectors reviewed reactor physics testing results to verify that core operating limit parameters were consistent with the design.
b. Findings
No findings were identified.
.4 Identification and Resolution of Problems
a. Inspection Scope
Periodically, the inspectors reviewed the items that had been entered into the CAP to verify that the licensee had identified problems related to outage activities at an appropriate threshold and had entered them into the corrective action program. For the significant problems documented in the corrective action program and listed below, the inspectors reviewed the results of the investigations to verify that the licensee had determined the root cause and implemented appropriate corrective actions, as required by 10 CFR 50, Appendix B, Criterion XVI, Corrective Action.
- 413865, Inoperability of Pressurizer Heaters from B train EDG
b. Findings
No findings were identified.
==1R22 Surveillance Testing
a. Inspection Scope
==
For the eight surveillance tests listed below, the inspectors witnessed testing and/or reviewed the test data to verify that the systems, structures, and components involved in these tests satisfied the requirements described in the TS, the UFSAR, and applicable licensee procedures, and that the tests demonstrated that the SSCs were capable of performing their intended safety functions. Documents reviewed are listed in the
.
- OST-750-2, Control Room Emergency Ventilation System-Train B, Rev. 18
- OST-554, Turbine Bearing Oil System and E-H Control System Hydraulic Components Test (Monthly), Rev. 20
- OST-413, Temporary Skid Diesel Generator, Rev. 8
- OST-551-1, Turbine Valve Test, Rev. 4
- SPP-038, Installation, Operation, and Removal of Supplemental Cooling for HVH-1, 2, 3, & 4, Rev. 11
Inservice Testing Surveillance
- OST-108-3, Comprehensive Flow Test For Boric Acid Pump A, Rev. 12
- Containment Isolation Valve Surveillance OST-014, LLRT of Personnel Air Lock Door Seals (Within Three Days of Entry When CV Integrity is Required), Rev. 15 Reactor Coolant System Leakage Surveillance
- OST-051, Reactor Coolant Leakage Evaluation (Every 72 Hours During Steady State Operation and Within 12 Hours of Reaching Steady State Operation) Rev. 44
The inspectors reviewed the following AR associated with this area to verify that the licensee identified and implemented appropriate corrective actions:
- 474876, Increase in Unidentified Reactor Coolant System Leakage
b. Findings
No findings were identified.
Cornerstone: Emergency Preparedness
1EP6 Drill Evaluation
a. Inspection Scope
On July 26, 2011, the inspectors observed an emergency preparedness drill to verify licensee self-assessment of classification, notification, and protective action recommendation development in accordance with 10 CFR 50, Appendix E. The inspectors also reviewed the Post-Drill Critique Roll-Up and Review Checklist to verify that the licensee properly identified failures in classification, notification and protective action recommendation development activities.
b. Findings
No findings were identified.
OTHER ACTIVITIES
4OA1 Performance Indicator (PI) Verification
a. Inspection Scope
The inspectors verified the PIs identified below. For each PI, the inspectors verified the accuracy of the PI data that had been previously reported to the NRC by comparing those data to the actual data, as described below. The inspectors also compared the licensees basis in reporting each data element to the PI definitions and guidance contained in NEI 99-02, Regulatory Assessment Indicator Guideline. In addition, the inspectors interviewed licensee personnel associated with collecting, evaluating, and distributing these data.
Initiating Events Cornerstone
- Unplanned Scrams per 7000 critical hours
- Unplanned Scrams with Complications
- Unplanned Power Changes per 7000 critical hours
For the period from the first quarter of 2010 through the fourth quarter of 2010, the inspectors reviewed a selection of licensee event reports, operator log entries, daily reports (including the daily CR descriptions), monthly operating reports, and PI data sheets to verify that the licensee had accurately identified the number of scrams and unplanned power changes greater than 20 percent that occurred during the subject period. The inspectors compared those numbers to the numbers reported by the licensee for the PI. The inspectors also reviewed the accuracy of the number of critical hours reported, and the licensees basis for crediting normal heat removal capability for each of the reported reactor scrams.
b. Findings
No findings were identified.
4OA2 Identification and Resolution of Problems
.1 Routine Review of ARs
a. Inspection Scope
To aid in the identification of repetitive equipment failures or specific human performance issues for follow-up, the inspectors performed frequent screenings of items entered into the CAP. The review was accomplished by reviewing daily AR reports.
b. Findings
No findings were identified.
.2 Annual Sample Review
a. Inspection Scope
The inspectors selected AR 463241463241 Response to AR 422989422989 Decline in Corrective Action Program (CAP) Performance noted similarities with the Davis Besse CAP decline lessons learned for detailed review. The inspectors reviewed this report to verify:
- complete and accurate identification of the problem in a timely manner;
- evaluation and disposition of performance issues;
- evaluation and disposition of operability and reportability issues;
- consideration of extent of condition, generic implications, common cause, and previous occurrences;
- appropriate classification and prioritization of the problem;
- identification of root and contributing causes of the problem;
- identification of corrective actions which were appropriately focused to correct the problem; and
- completion of corrective actions in a timely manner.
b. Observations and Findings
No findings were identified. The inspectors noted that licensees review of the corrective actions implemented as a result of the Davis Besse reactor vessel head degradation was thorough and comprehensive. The licensee determined that some corrective actions involving ongoing periodic reviews of the event with staff had lost the clear linkage of the Davis Besse event with the purpose of the reviews. The licensee added additional guidance to directly link the Davis Besse event to the review session.
.3 In-Depth Review of Operator Workarounds
a. Inspection Scope
The inspectors performed a detailed review of the Operator Workarounds and Operator Burdens List as of July 28, 2011, to verify the full extent of the issues were identified, an appropriate evaluation was performed, and appropriate corrective actions were specified and prioritized. The inspectors reviewed and walked down selected Caution Tags to assess the impact to the operators. The inspectors met with Operations management to discuss the current status of the Operator Workaround and Operator Burdens list.
b. Findings
No findings were identified.
4OA3 Event Follow-up
.1 (Closed) LER 2011-001-00, Condition Prohibited by Technical Specifications When
Non-Seismic System was Aligned to Refueling Water Storage Tank due to Regulatory Requirements not Adequately Incorporated in Plant Documentation.
On May 4, 2011, the licensee determined that over the last 40 years, the plant periodically performed cleanup of the Refueling Water Storage Tank (RWST) by aligning the non-seismically qualified refueling water purification system to the safety-related and seismically qualified RWST without recognizing that the action rendered the RWST inoperable. As a result, on multiple occasions the RWST was inoperable for a period longer than allowed by Technical Specifications. The cause of this event was that regulatory requirements for the separation of seismically qualified and non-seismically qualified SSCs were not adequately incorporated into the Design Basis Document and the UFSAR. The inspectors reviewed the corrective actions and determined that they were adequate. The enforcement aspects of this LER were documented in IR 05000261/2011003, Section 1R15, as a Green NCV 05000261/2011003-03. The LER was reviewed and no additional findings were identified and no additional violations of NRC requirements occurred. This LER is closed.
4OA5 Other Activities
.1 Quarterly Resident Inspector Observations of Security Personnel and Activities
a. Inspection Scope
During the inspection period, the inspectors observed Security force personnel and activities to ensure that the activities were consistent with licensee security procedures and regulatory requirements relating to nuclear plant security. These observations took place during both normal and off-normal plant working hours.
These quarterly resident inspector observations of security force personnel and activities did not constitute any additional inspection samples. Rather, they were considered an integral part of the inspectors normal plant status review and inspection activities.
b. Findings
No findings were indentified.
.2 Operation of an Independent Spent Fuel Storage Installation (ISFSI)
a. Inspection Scope
The inspectors performed a walkdown of the two ISFSIs on site (reference dockets 72-3 and 72-60) and monitored the activities associated with the dry fuel storage campaign conducted July 11 through July 15. The inspectors also reviewed changes made to programs and procedures and their associated 10 CFR 72.48 screens and/or evaluations to verify that changes made were consistent with the license or Certificate of Compliance; reviewed records to verify that the licensee has recorded and maintained the location of each fuel assembly placed in the ISFSIs; and reviewed surveillance records to verify that daily surveillance requirements were performed as required by technical specifications. Documents reviewed are listed in the attachment.
b. Findings
No findings were identified.
4OA6 Meetings, Including Exit
On November 14, 2011, the resident inspectors presented the inspection results to Mr.
Thomas Cosgrove and other members of his staff. The inspectors confirmed that proprietary information was not provided or examined during the inspection.
ATTACHMENT:
SUPPLEMENTAL INFORMATION
KEY POINTS OF CONTACT
Licensee personnel
- R. Buzard, Licensing
- T. Cosgrove, Plant General Manager
- H. Curry, Training Manager
- S. Garrity, Environmental & Chemistry Superintendent
- W. Gideon, Vice President
- K. Drown, Nuclear Assurance Manager
- B. Houston, Radiation Protection Superintendent
- C. Kamilaris, Manager, Support Services - Nuclear
- G. Kilpatrick, Operations Manager
- L. Martin, Engineering Manager
- B. Matherne, Outage & Scheduling Manager
- C. Morris, Maintenance Manager
NRC personnel
- R. Musser, Chief, Reactor Projects Branch 4
LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED
Opened
- 05000261/2011004-01 AV Water Intrusion into Safety-Related Buildings due to Inadequate Design of Site Storm Water Runoff Drainage System (Section 1R01)
Closed
- 05000261/2011003-01 URI Rainstorm Results in Flooding of the Power Block (Section 1R01)
- 05000261/2011-001-00 LER Condition Prohibited by Technical Specifications When Non-Seismic System was Aligned to Refueling Water Storage Tank due to Regulatory Requirements not Adequately Incorporated in Plant Documentation (Section 4OA3)
Opened &
Closed
- 05000261/2011004-02 NCV Failure to Take Prompt Corrective Actions to Establish Guidance to Monitor and Operate Service Water Strainers Following LOOP (Section 1R15)
Discussed
None