Forwards SALP Repts 50-413/97-99 & 50-414/97-99 for Period of 951008-970426.Performance in Operations,Maint,Engineering & Plant Support Improved to Superior Level
ML20140E764
Person / Time
Site: Catawba  Duke energy icon.png
Issue date: 06/04/1997
From: Reyes L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Mccollum W
DUKE POWER CO.
Shared Package
ML20140E767 List:
References
50-413-97-99, 50-414-97-99, NUDOCS 9706120197
Download: ML20140E764 (4)


See also: IR 05000413/1997099

Text

( . -- . . ~

.

,

d.8

l

t

June 4, 1997

l

l

l Duke Power Company

l ATTN: Mr. W. R. McCollum

'

Vice President

Catawba Site

4800 Concord Road -

i York. SC 29745-9635

SUBJECT: SYSTEMATIC ASSESSMENT OF LICENSEE PERFORMANCE (SALP)

l, , (NRC INSPECTION REPORT NO. 50-413/97-99 AND 50-414/97-99)

l Dear Mr. McCollum:

E

The U.S. Nuclear Regulatory Commission (NRC) has completed the Systematic

Assessment of Licensee Performance (SALP) for the Catawba Nuclear Station.

The facility was assessed for the period of October 8.1995, through

i April 26, 1997. The results of the assessment are documented in the enclosed

l SALP report, which,will be discussed with you at a public meeting at the

l Catawba site on June 23, 1997, at 1:00 p.m.

1

Plant performance was assessed in four functional areas: Plant Operations.

. Maintenance, Engineering, and Plant Support. Performance in the areas of

Plant Operations Engineering, and Plant Support improved to a superior level. ,

Contributors to this achievement were improved program implementation by your j

staff, effective self-assessment and management involvement. The assessment

'

of these three functional areas indicates that the Station staff was effective

in addressing the challenges discussed in the previous SALP' report.

The level of performance in the Maintenance area remained good. This area

also benefited from improved self-assessment and management: involvement.

Equipment reliability, procedure inadequacies and problems in the welding

program require your attention and detracted from obtaining a higher category

rating in this area.

,

. In accordance with Section 2.790 of the NRC's " Rules of Practice." a copy of

this letter and its enclosure will be placed in the NRC Public Document Room.

l

I

,

i I l

i \ l

<

\

l- " \

9706120197 970604 IlEMI

! PDR ADOCK 05000413

l G pm ~

fllPMW'

.

'a $bh.kf

I

l

i , . - - -

.- - -- . . . .-

56#

- - - -

\

. . -- - . . - . ~ . _ _ . - ._ _ - - - _ - .. - - .. .- - . . - - _

. . ,

,

t

! t

!

DPC 2  ;

! Should you have any questions or comments. I would be pleased to discuss them  !

l with you.  !

Sincerely.  ;

Original signed by Luis A. P, eyes  !

Luis A. Reyes i

Regional Administrator  !

Docket Nos. 50-413 and 50-414

License Nos. NPF-35 and NPF-52

,

Enclosure: SALP Report

]

cc w/ encl: i

M. S. Kitlan

Regulatory Compliance Manager

Duke Power Company ,

4800 Concord Road i

York. SC 29745-9635 i

i

Paul R. Newton i

Legal Department (PB05E) .

Duke Power Company i

422 South Church Street I

Charlotte. NC 28242-0001 i

)

Robert P. Gruber

Executive Director

'

Public Staff - NCUC

P. O. Box 29520

Raleigh. NC 27626-0520

J. Michael McGarry. III. Esq.

Winston and Strawn

1400 L. Street. NW

Washington. D.C. 20005

North Carolina MPA-1

Suite 600

P.O. Box 29513

Raleigh. NC 27626-0513

cc w/ encl cont'd: (See page 3)

t

l

l

,

- . - - _ . .. . _ - .. - .- _. - - . ._ _ - - - . . _ - -

.

. t

.

.

I 3

DPC

cc w/ encl cont'd: cc w/ encl:

Max Batavia. Chief G. A. Copp

Bureau of Radiological Health Licensing - EC050

S. C Department of Health Duke Power Company

and Environmental Control P. O. Box 1006

, 2600 Bull Street Charlotte NC 28201-1006

l Columbia. SC 29201

! T. Richard Puryear

i Richard P. Wilson Esq. Owners Group

i Assistant Attorney General North Carolina Electric

l S. C. Attorney General's Office Membership Corporation

P. O. Box 11549 4800 Concord Road

Columbia. SC 29211 York. SC 29745

l

Michael Hirsch Distribution w/ enc 1: (See page 4)

l Federal Emergency Management Agency

l

500 C Street SW. Room 840

Washington D. C. 20472

North Carolina Electric

Membership Corporation

P. O. Box 27306

Raleigh NC 27611

l Karen E. Long

Assistarit Attorney General

'

N. C. Department of Justice

l P. O. Box 629

Raleigh. NC 27602

l

Saluda River Electric

Coo)erative, Inc.

P. O. 3cx 929

Laurens. SC 29360

i Peter R. Harden IV

Account Sales Manager

l Westinghouse Electric Corporation

! P. O. Box 7288

l Charlotte. NC 28241

, County Manager of York County

l York County Courthouse

York. SC 29745

Piedmont Municipal Power Agency

!

'

121 Village Drive

Greer. SC 29651

'

INP0

i

_.. . _ . _ . . _. _ _ . . _ . _ _ _ . _ - _ _ _ . _ . _ _ _ _ . _ _ _ _ . _ . _ . _ _ . _

.

< i

,

'

,

!

DPC 4

Distribution w/ encl:

Chairman Jackson

Commissioner Rogers

Commissioner Dicus >

Commissioner Diaz ,

Commissioner McGaffigan

J. L. Callan EDO

H. L. Thom] son, Jr., DEDR

G. Tracy. Regional '

Coordinator. EDO

A. J. Galante, CIO l

J. L. Funches, CFO

S. J. Collins, NRR  :

J. Lieberman. OE 1

S. A. Varga. NRR '

F. J. Miraglia, NRR

C. W. Hehl. RI

G. Grant, RIII

P. Gwynn, RIV

K. E. Perkins, WCF0

J. Gamberoni, SALP Program Manager,

NRR

A. P. Hodgdon. OGC

B. K Keeling, GPA/CA

P. Tam, NRR

R. Carroll. RII

C. Casto. RII

K. Clark, RII. PA0 l

DRS Branch Chiefs

.NRC Resident _ Inspector

PUBLIC

Federal Emergency Management Agency

ATTN: Mr. John C. Heard, Jr. , Chief

~ Technical Hazards Branch

3003 Chamblee-Tucker Road

Chamblee. GA 30341  ;

orFICE RII DPS RII D PIf NR9 #ff DDP Pff DRS Pff-DRS

SIGNATURE (

NAME CCasto JJaudon W erkow Johnson BMallett

DATE / / 97 k/ bl 97 052 3 0 / 97 h/1/97 Okh / 97 05 / / 97

COPY? YES fic) %E'S) - NO (YEd N0 (E5) NO [YEh NO YES NO

Ort 1CIAL RtLURU COPY M UMt.Ni NAM-. C:\CAiSLP13,R2 V

l

1

l

l