2005 Inservice Inspection Report
ML052630030
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 09/08/2005
From: Jones T
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2005-190
Download: ML052630030 (321)


Text

{{#Wiki_filter:SEP 0 0 22.5 L-2005-1 90 FPL , 0CFR 50.55a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: Turkey Point Unit 4 Docket No. 50-251 2005 Inservice Inspection Report Attached are the Executive Summary and the following reports for Turkey Point Unit 4 in accordance with the provisions of the ASME Code, Section XI: Form NIS-1 Owners' Report for Inservice Inspections Abstract of Examinations and Tests 3rd 10 Year Interval Closeout Abstract of Examinations and Tests 4th 10 Year Interval- 1St Period Summary of Inservice Inspection Examinations 3rd 10 Year Interval Closeout Summary of Inservice Inspection Examinations 4th 10 Year Interval- 1 st Period Summary of Inservice Inspection IWE Examinations Summary of Visual Examinations and Functional Testing of Snubbers Summary of System Pressure Testing Form NIS-2 Owners' Report for Repairs or Replacements Should there be any questions concerning this report, please contact Walter Parker at 305-246-6632. Very truly you Terry .Jo es Vice President Turkey Point Nuclear Plant SM Attachments NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC t4/1 an FPL Group company

TURKEY POINT PLANT UNIT 4 2005 REFUELING OUTAGE INSERVICE INSPECTION REPORT Executive Summary This Inservice Inspection report is for the 2005 Turkey Point Unit 4 refueling outage. This was the first outage of the first period of the fourth 10-year interval. Additionally, a limited number of examinations, specifically RPV examinations, were examined and credited in accordance with the requirements of the third 10-year interval. The third 10-year interval was extended by eleven months by implementing paragraph IWA-2430(d) of ASME Section XI. This extension was necessary to meet the station's goals and to schedule work in an effective manner consistent with ALARA principles. The Turkey Point licensing conducted a phone conversation with the Nuclear Regulatory Commission on June 12, 2003 to discuss this matter and a letter, L-2203-158, was submitted on June 20, 2003. Inservice examinations consisted of augmented Feedwater ultrasonic examinations on the A, B and C Steam Generator Feedwater nozzles, adjacent piping, and fittings. Also examined were selected components from the Reactor Pressure Vessel, Reactor Coolant, Pressurizer, Residual Heat Removal, Safety Injection, Main Feedwater, Auxiliary Feedwater, Steam Generator Blowdown, Steam Generator A Primary Side, Steam Generator C Secondary Side, Chemical and Volume Control, Component Cooling Water, Intake Cooling Water, and Waste Disposal System. The attached Inservice Inspection summary tables detail the examinations performed during the outage. Examinations credited to the Third Interval are detailed in Attachment I and Table 1. The examinations credited to the Fourth Interval are detailed in Attachment 2 and Table 2. This outage completed the third 10-year interval and the first outage of the first period of the fourth 10-year interval. The NIS-2 forms document the repair and replacement activities that have taken place since the previous Unit 4 submittal, and those performed during the 2005 refueling outage. IWE preservice examinations were performed in areas of coating repairs to the containment metallic liner and moisture barrier seal. A preservice examination was also performed on the containment liner where the hole was cut for the passage of the new reactor head. Reference Attachment 3 for examination scope and results. There were no IWL examinations scheduled for this outage. However, a preservice examination was performed on the tendons and concrete surfaces where a hole was cut for the passage of the new reactor head. Snubber visual examinations and functional tests were conducted in accordance with ASME Section XI and Turkey Point Plant Technical Specifications. Reference Attachment 4, Summary of Visual Examinationsand FunctionalTesting of Snubbers, for examination scope and results. System pressure testing was conducted in accordance with the requirements of ASME Section XI and Turkey Point Technical Specifications. Reference Attachment 5, Summary of System PressureTesting, for test boundaries and results. There was no Steam Generator eddy current examinations scheduled for this outage.

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS Page 1 of 8

1. Owner: Florida Power and Light Company 700 Universe Blvd.

Juno Beach, Florida 33408

2. Plant: Florida Power & Light Company Turkey Point Nuclear Power Plant 9760 SW 344 Street Florida City, Florida 33035
3. Plant Unit: 4 4. Owner Certificate of Authorization (if required): N/A
5. Commercial Service Date: September 7. 1973 6. National Board Number for Unit: N/A
7. Components Inspected:

Component or Manufacturer or Manufacturer State or Province National Board Appurtenance Installer Serialler No. No. Reactor Pressure Babcock and 610-0116 N/A N-161 Vessel Wilcox Pressurizer Westinghouse HTPT-0021 N/A N-68-1 Regenerative Heat Wetnhue41200 N/A N/A Exchanger Westinghouse Reactor Coolant Bechtel N/A N/A N/A System Reactor Coolant 4-618J713 Pump C Westinghouse 2S76P499 N/A N/A Safety Injection Bechtel N/A N/A N/A System Residual Heat Bechtel N/A N/A N/A Removal System Steam Generator 16A-6341-1 & 3 ABCWestinghouse FSGT-2991 & N/A N-772 and N-776 ABC ~~~~~2993_ _ _ _ _ _ _ _ _ _ _ _ _ _ Main Steam Bechtel N/A N/A N/A System__ _ _ _ _ _ _ _ _ _ _ _ Main Steam Blowdown Bechtel N/A N/A N/A System Waste Disposal Bechtel N/A N/A N/A System Bechtel N/A N/A N/A Main Feedwater Bechtel N/A N/A N/A S ystem I _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

FORM NIS-1 Report Page 2 of 8 Owner: Florida Power &Ught Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit 4 Owner Certfcate of Authorization (if required) NIA Commercial Service Date: September 7, 1973 National Board Number for Unit: N/A Component or Manufacturer or Manufacturer State or Province National Board Appurtenance Installer Serialler No. No. Auxiliary Bechtel N/AN/A N/A Feedwater Chemical and Bechtel N/A N/A N/A volume Control Component Bechtel N/A N/A N/A Cooling Water Intake Cooling Bechtel N/A N/A N/A W ater__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8. Examination Dates: from 11/5/2003 to 6/13/2005
9. Inspection Period Identification: First Period, from 04/15/2004 to 04/14/2007.
10. Inspection Interval Identification: Fourth Interval, from 04/15/2004 to 04/14/2014.
11. Applicable Edition of Section XI: 1998 Edition. 2000 Addenda. CwE/IWL) 1992/1992 Addenda
12. Date/Revision of Inspection Plan: April 15. 2004 Rev. 0.
13. Abstract of examinations and test. Include a list of examinations and tests and a statement concerning status of work required for the inspection plan.

Inservice Examination of selected Class 1, 2 and 3 components and piping systems of Florida Power and Light's (FPL) Turkey Point Unit 4 were performed during the 2005 Refueling Outage. This cycle began on 11/5/2003 and ended 6/13/2005. This was the first outage of the first period of the fourth 10-year interval. Additionally, a limited number of examinations specifically RPV examinations, were examined and credited in accordance with the requirements of the third 10-year interval. The third 10-year interval was extended by eleven months by implementing paragraph IWA-2430(d) of the 1989 Edition, No Addenda of ASME Section M. This extension was necessary to meet the station's goals and to schedule work in an effective manner consistent with ALARA principles. The Turkey Point licensing group conducted a phone conversation with the Nuclear Regulatory Commission June 12, 2003 to discuss this matter and followed up with a letter, L-2003-158 on June 20, 2003. The components and piping systems examined were selected in accordance with the Third ten-year interval program or Fourth Ten-Year Inservice Inspection Program. The inspection plans include an alternative to the examination and Pressure Test requirements of Table IWB-2500-1, Category B-F and B-J piping welds, as defined in American Society of Mechanical Engineers

FORM NIS-1 Report Page 3 of 8 Owner: Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant Turkey Point Nuclear Power Plant, 9760 SW 344 Street. Florida City, Florida 33035 Plant Unit 4 Owner Certificate of Authorization (if required) NIA Commercial Service Date: September 7. 1973 National Board Number for Unit: N/A (ASME) Section XI, 1989, No Addenda and the 1998 Edition with Addenda through 2000. This alternative implements a risk informed inspection program for the examination selection for the Class 1, Category B-F and B-J piping welds in lieu of the requirements of Table JWB-2500-1. The alternative Plan allows examination selection for Unit 4 to be in accordance with "Florida Power & Light Turkey Point Unit 4 Risk-Informed Inservice Inspection Program. Manual ultrasonic, radiography, visual, magnetic particle, and liquid penetrant non-destructive methods were used to examine components, piping, and their supports. FPL personnel supported by Washington Group International personnel performed the examinations. Reference Attachment 1 and 2 and Table 1 and 2, Turkey Point Unit 4 Inservice Inspection, for examination scope, results, and percentages completed. Framatome personnel performed automated ultrasonic and remote visual on the girth welds, inside surfaces, and internals of the reactor pressure vessel that were credited to the third 10-year inservice inspection examination. Snubber visual examinations and functional testing were conducted in accordance with ASME Section Xl and Turkey Point Technical Specifications. Basic-PSA, Inc supplied examination and testing services. Reference Attachment 4, Summary of VisualExaminationsandFunctional Testing of Snubbers, for examination scope and results. FPL visual examiners conducted system pressure testing in accordance with the requirements of ASME Section X and Turkey Point Technical Specifications. Reference Attachment 5, Summary of System Pressure Testing, for test boundaries and results. No scheduled IWE examinations were required this outage. Preservice examinations were performed in areas of coating repairs to the containment metallic liner and moisture barrier seal. A preservice examination was also performed on the containment liner where the hole was cut for the passage of the new reactor head. Reference Attachment 3 for examination scope and results. There were no IWL examinations scheduled for this outage. However, a preservice examination was performed on the tendons and concrete surfaces where a hole was cut for the passage of the new reactor head.

-FORM NIS-1 Report Page 4 of 8 Owner. Florida Power & Ught Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit 4 Owner Certificate of Authorization (if required) N/A Commercial Service Date: September 7. 1973 National Board Number for Unit: N/A

14. Abstract of Results of Examinations and Tests.

Refer to Attachment I and 2 for list of components and examination results during the Spring 2005 outage.

15. Abstract of Corrective Measures Outlet Nozzle Surface at 130- and 250 was found to have recordable indications at the nozzle seating surface. At the 250 outlet nozzle, vertical gouges were found at the 6 o'clock position on the nozzle seating surface running the entire width of the face. At the 130' outlet nozzle, shallow vertical gouges were found at the 4 & 6 o'clock position of the nozzle seating surface running the width of the face. Engineering Disposition: The primary concerns with the contact marks on the RV outlet nozzle seating surface between the core barrel at the 1300 and 2500 locations are as follows:
1) Significant raised metal could result in abnormal operational loads on the RV nozzle.
2) Could the raised metal become a loose part?
3) Gouges on the RV hot leg nozzle bosses could expose the carbon steel substrate.

The following addresses the concerns identified above:

1) Significant raised metal could result in abnormal operational loads on the RV nozzle:

Examination of the raised faces of the bosses on the RV and core barrel revealed only shallow contact marks without any significant raised metal or deformation. The only deformation noted was on the lead in of the 2500 RV outlet boss at 12:00, which did not appear to contact the corresponding face on the core barrel boss. Therefore the shallow contact/scrape marks at the 1300 and 2500 nozzle locations do not result in abnormal operational loads being applied to the RV outlet nozzle.

2) There was no raised metal observed on the outlet nozzle bosses at the 130'and 2500 locations that could result in foreign material entering the RCS.
3) Gouges on the RV hot leg nozzle bosses could expose the carbon steel substrate: The clad thickness on the faces ofthe RV outlet nozzle bosses is -1 inch thick (5610-M-400-1 7). The contact/scrape marks on the RV outlet nozzles appear to be very shallow based on comparison to machine marks on the boss surfaces (< 1/32") and no rust discoloration. The core barrel boss is all stainless steel. Therefore there are no concerns with a breach of the clad surface that would expose the carbon steel substrate.

Conclusion:

The marks on the core barrel outlet nozzle bosses and RV outlet nozzle bosses at the 130Oand 2500 nozzle locations are the result of normal contact between the reactor vessel and the core barrel during insertion and removal. The marks appear to be very shallow based on

-FORM NIS-1 Report Page 5 of 8 Owner. Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit 4 Owner Certificate of Authorization (if required) N/A Commercial Service Date: September 7. 1973 National Board Number for Unit: N/A comparison with the depth of adjacent surface machining marks and do not appear to impose any abnormal loads on the RV outlet nozzles during service. The severity of the contact between the vessel and the core barrel is minimized by FPL procedure (0-GMM-043.21) through constant monitoring of the load cell on the polar crane hook and slow hook speeds during the critical insertion and removal operations. No corrective actions are required since outlet nozzle bosses maintain a tight fit that minimizes the bypass of RCS fluid from the RV annulus to the hot leg. The shallow scratches did not expose any carbon steel on the RV outlet nozzle surface. There is also no concern for loose parts as a result of the contact marks. Therefore this condition is not a condition adverse to quality. The condition is acceptable. Reference CR 2005-13224. Irradiation Specimen Capsule at 30. 230'. and 270 was found to have recordable indications on the surface of the capsules. At the 30 irradiation capsule, gouges were seen located near the bottom of the capsule and about 2 feet in length running vertically. Also another area of gouging was noted at the very bottom on the tapered show running in the horizontal direction. At the 230- irradiation capsule, gouges were seen located from top to bottom on one side of the capsule running vertically for the entire length. Also, in numerous places along the base material chafing was seen and peeling along the outside edges of the gouge were also noted. At the 270 irradiation capsule, a gouge was seem about 1/3rd down from top of capsule running in the horizontal direction for about half the width of the capsule. Engineering Disposition: The primary concerns with the contact marks on the capsule holders at the 30°, 2300, and 270° locations are as follows:

1) Loose parts - Capsule holder separating from the internals thermal shield.
2) Deformation of the corresponding RV flange slots. Deformation could result in non uniform contact loads on the vessel flange.
3) Gouges on the RV flange slots causing raised metal and/or loose parts or exposed carbon steel.

The following addresses the concerns identified above:

1) Loose Parts: As part ofthe visual examination ofthe internals, the welds between the surveillance capsule holders and the thermal shield were examined. No evidence of cracks or deformation to the welds or capsule holders was observed. Therefore, there are no loose parts concern associated with this condition.
2) Deformation of the corresponding RV flange slots: The slots in the RV flange ledge at the 300, 2300, and 2700 locations, corresponding to the capsule holder contact marks, were examined for evidence of degradation. Light surface contact marks were also observed in the vertical surfaces of the capsule slots at the 300, and 2300 locations. No deformation was observed on the horizontal surface ofthe flange ledge at the top of the slots. No contact marks or deformation was observed in the slot at the 2700 location. Since there was no deformation to the flange ledge, there is no change in the contact loads on the vessel flange.

FORM NIS-1 Report Page 6 of 8 Owner. Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit 4 Owner Certificate of Authorization (if required) NIA Commercial Service Date: September 7. 1973 National Board Number for Unit: N/A

3) Gouges on the RV flange slots causing raised metal and/or loose parts or exposed carbon steel:

The examination of the slots in the RV flange ledge did not identify any significant gouges or raised metal that could result in loose foreign material entering the RCS. The marks on the vessel flange slots at 300 and 230'were superficial and did not penetratethe cladding. There was no corresponding rub mark in the slot at the 270° location. Therefore there are no concerns with raised metal becoming a loose part or penetrating through the clad surface and exposing the carbon steel substrate.

Conclusion:

The marks on the surveillance capsule holders are the result of normal contact with the slots in the reactor vessel flange during insertion and removal ofthe lower internals. The severity of the contact between the vessel and the internals is minimized by FPL procedure (0-GMM-043.21) through constant monitoring of the load cell on the polar crane hook and slow hook speeds during the critical insertion and removal operations. No corrective actions are required since these contact marks do not affect the function of the surveillance capsule holders; the marks on the corresponding flange slot do not affect the loads on the reactor vessel. There is also no concern for loose parts as a result of the contact marks. Therefore, this is not a condition adverse to quality. The condition is acceptable. Reference CR 2005-13231 Replacement reactor head mating surface to vessel was found to have a rounded indication on the surface of the inner groove at stud location number 6. Engineering disposition found that the indication is not located in the primary sealing surface and does not have any raised metal associated with the indication. Use as-is. Reference CR 2005-6129 and Framatome CR 2005-735. Residual Heat Removal piping support (SR-450C) was found to have the cold setting out of tolerance with the design drawing. Engineering disposition directed to have the spring hanger adjusted to the design drawing cold setting of 2635 lbs and a final VT-3 performed. Work was performed under W.O. No. 34003021. Reference CRNo. 2005-10974. Residual Heat Removal piping support (PS-3) was found to have the clearances not within tolerances of the drawing, chaffing on the tube steel, and a drawing discrepancy with the welded lugs. Engineering disposition found that the combined maximum gap was within tolerance of Engineering Standard, STD-C-01 1 and the chaffing observation was to the coating only and no material damage occurred. Also, the missing weld on the lugs was apparently due to difficulty in welding the inside section of the weld. The analysis shows that the amount of weld missing will have minimal affect on the support. Therefore, no adverse condition exists and the design drawing will be corrected per CRN-C-1 1588 to reflect the actual field configuration. Reference CR No. 2005-11852. Safety Injection piping support 8081-H-001-14 was found to have the cold setting out of tolerance with the design drawing. Engineering disposition directed to have the spring hanger

FORM NIS-1 Report Page 7 of 8 Owner: Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit 4 Owner Certificate of Authorization (if required) NIA Commercial Service Date: September 7. 1973 National Board Number for Unit: N/A adjusted to the design drawing cold setting of 69 Ibs and a final VT-3 performed. Work was performed under W.O. No. 34003021. Reference CRNo. 2005-10976. Residual Heat Removal piping support 8073-H-809-05 was found to have the clearances not within tolerances of the drawing. Engineering disposition found that the combined maximum gap was within tolerance of Engineering Standard, STD-C-01 1. Therefore, no adverse condition exists and no drawing update or corrective actions are required. Reference CR No. 2005-11049. Feedwater Bypass piping support 7884-R-014-01 was found to have clearance gaps outside the specified dimensions of the support drawing. Engineering disposition found that the combined maximum gap was within tolerance of Engineering Standard, STD-C-01 1. Therefore, no adverse condition exists and no drawing update or corrective actions are required. Reference CR No. 2005-10658. Auxiliary Feedwater piping support 80117-H-324-13 was found to have clearance gaps outside the specified dimensions of the support drawing and a 3/4" rod was rubbing a measurable wear spot on the L-beam. Engineering disposition found that the combined maximum gap was within tolerance of Engineering Standard, STD-C-01 I and the metal loss on the structural angle is negligible and will not impact the structural integrity of the member. Therefore, no adverse condition exists and no drawing update or corrective actions are required. Reference CR No. 2005-10665. Normal Containment Cooler support 4V1A was found to have a loose nut/bolt assembly on the support base. Engineering disposition directed to have the nut/bolt assembly tightened and a final VT-3 performed. Work was performed under Work Order 33023494. Reference CRNo. 2005-10979.

FORM NIS-1 Report Page 8 of 8 Owner Florida Power &Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit 4 Owner Certificate of Authorization (if required) N/A Commrercial Service Date: September 7, 1973 National Board Number for Unit: N/A We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section X, and c) corrective measures taken conform to the rules of the ASME Code, Section XI. Certificate of Authorization No. N/A Expiration Date vJ 1, Date: c_______ __ Signed: By e c ' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Florida, and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut of Hartford, CT have inspected the components described in this Owner's Report during the period during the period 12/5/2003 to 6/13/2005, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI. By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. _ _ _ _ _ _ _ _ L 477 (A, C, MA I) Irispector's Signature National Board, State, Province, and Endorsements Date: PI-z-a:5

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE Abstract of Examinations and Tests Total Population and Percentages 3 rd Interval Closeout Table 1

Page 1 of 4 Table 1 (Post Spring 2005 Outage) Turkey Point Unit 4 THIRD INSPECTION INTERVAL - END OF INTERVAL ABSTRACT OF EXAMINATION AND TESTS Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) Credited (%) Remarks the Interval the Period for the period Interval B-A 6 6 100% 100% B11.11 3 Deferral Permissible B31.21 I___ ___ Deferral Permissible B 1.30 1 Code Case N-623 Applied, Deferral Permissible B1.40 1 B-B 5 2 40% 100% B2.11 2 _ __ ___ = B2.12 2 B2.40 1 B-D 24 14 58.3% 100% B3.90 6 Deferral Permissible B3.100 6 Deferral Permissible B3.120 6 B3.140 6 B-F RR #32 was submitted to implement a risk informed program and approved August 1, 2003. The B-F examination category items are included in the Category R-A population. B-G- 18 6 33.3% 100% Total includes Item B6.190 (only required if disassembled) B6.10 3 Deferral Permissible B6.30 3 Deferral Permissible B6.40 3 Deferral Permissible B6.50 6 Deferral Permissible B6.180 I Deferral Permissible B6.190 1 Deferral Permissible B6.200 I Deferral Permissible B-G-2 19 6 100% 100%

Page 2 of 4 Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) Credited (%) Remarks the Interval the Period for the period to Date for the ___________ _____________ Interval __________________________ B7.20 1 B7.30 6 ___ _ B7.50 9 B7.70 3 RR #32 was submitted to implement a risk informed program and approved August 1, 2003. The B-F examination category B-J items are included in the Category R-A population. B-K 4 1 25% 100% Code Case N-509 applied. RR #8 allows code % _ __ __ __ __ _ __ __ __ _ __ __ _ _ _ _ _ _ __ _ _ _ _ __ _ _ __ _ _ _ _ __ _ _ _ _ d evia tio n . B10.20 3 B10.30 1 B-L-1 3 3 100% 100% _ _ B12.10 3 Code Case N-481 applied. Deferral Permissible B-L-2 1 0 0% 0% B12.20 IPumps were not disassembled this Interval. _____ _ _Examination required only when disassembled B-M-2 3 1 33.3% 33.3% Group 3 valve disassembled only. 1 valve in each B12.50 3 group requires examination when disassembled for maintenance. Deferral Permissible B-N-i 10 10 100% 100% B13.10 10 Each item (8) must be examined each period B-N-2 1 1 100% 100% B13.60 1 Deferral Permissible B-N-3 27 27 100% 100% B13.70 27 Deferral Permissible B-Q 3 3 100% 100% B14.10 3 _ _ _ 1 1 Deferral Permissible B-P System leakage tests are performed each outage (IWB-5220) in accordance with plant procedures. B-QSteam Generator tubing is examined in accordance with Plant Technical Specifications. C-A 7 1 14.2% 100% CL.I0 4 C1.20 2

Page 3 of 4 Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) Credited (%) Remarks the Interval the Period for the period to Date for the ______________________________ Interval ________________________ C 1.30 I__ _ _ _ _ _ __ _ _ _ _ _ C-72 C-B72 25% 25%100%required 100% C-B totaleach not include C2.33 items that are doesperiod. C2.21 3-C2.22 2 C2.31 2 C2.33 4 VT examinations required each period. AS tell-tale was removed 2 d period. C-C 9 3 33.3% 100% Code Case N-509 applied. C3.10 1 C3.20 8 _______ ______________________________ C-F-1 52 19 36.5% 100% Total count includes circumferential welds only. C5.11 22 C5.12 6 C5.21 13 C5.22 0 C5.30 14 C5.41 3 Less than 28 welds would be required if 7.5% criteria C-F-2 28 14 50% 100% is followed, FPL raised the total count to 28 per note 2. Total count includes circumferential welds only. C5.51 22 _ _ C5.52 5 C5.81 6 C-H System pressure tests are performed in accordance w th plant procedure . Quantification of the number of tests is not practical. D-A 15 6 40% 100% Code Case N-509 applied. D1.10 4 D1.20 11 D-B System pressure tests are performed in accordance with plant procedure s. Quantification of the number of tests is not practical. F-A 121 49 39.1% 100% Code Case N-491-1 applied for all supports. FI.10 40 F1.20 34

Page 4 of 4 Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) CreDite for Remarks the Interval the Period for the period Interval F1.30 31 F1.40 16 R-A total does not include item R1.12. RR32 was R-A 20 12 60% 100% approved August 1, 2004 to implement the risk informed inspection program. RI.1 20 R1.12 129 Visual examinations are performed each outage.

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE Abstract of Examinations and Tests Total Population and Percentages 4 th Interval - 1 st Period Table 2

Page 1 of 4 Table 2 (Post Spring 2005 Outage) Turkey Point Unit 4 FOURTH INSPECTION INTERVAL - FIRST PERIOD ABSTRACT OF EXAMINATION AND TESTS Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) Credited (%) Remarks the Interval the Period for the period Interval the B-A 5 0 0% 0% B1.11 3  ; Deferral Permissible B 1.21 1 ________Deferral Permissible B1.30 1 Code Case N-623 Applied, Deferral Permissible B-B 5 1 100% 20% B2.11 2 B2.12 2 B2.40 1 B-D _ 24 0 0% 0% B3.90 6 Deferral Permissible B3.100 6 Deferral Permissible B3.120 6 B3.140 6 B-F RR #4 being submitted to implement a risk informed program. The B-F examination category items are included in the Category R-A poulation. B-G-1 18 3 100% 16.6% Total includes Item B6.190 (only required if disassembled) B6.10 3 Deferral Permissible B6.30 3 Deferral Permissible B6.40 3 Deferral Permissible B6.50 6 Deferral Permissible B6.180 IDeferral Permissible B6.190 I Deferral Permissible B6.200 I Deferral Permissible B-G-2 19 4 50% 21% B7.20 1

Page 2 of 4 Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) Credited (%) Remarks the Interval the Period for the period to Date for the the the Intervl Perid for theInterval __________________________ B7.30 6 B7.50 9 B7.70 3 B-J RR # being submitted to implement a risk informed program. The B-F examination category items are included in the Category R-Apopulation. 4(1s Period) B-K 6 (2 nd& 3 1 100% 25% Interval) _ B1O.10 2 Baseline performed on 6 new welds in the lS period. 0._ 0 25% will be performed in the next two periods. B10.20 3 B10.30 1 B-L-1 3 0 0% 0% B12.10 3 Deferral Permissible B-L-2 I Partial 50% 50% Diffuser was left in place. B12.20 I Examination required only when disassembled B-M-2 3 1 33.3% 33.3.% B12.50 3 1 valve in each group requires examination when

             ._                                                                     disassembled for maintenance. Deferral Permissible B-N-1                   10              0                  0%             0%

B13.10 10 Each item (7) must be examined each period B-N-2 I 0 0% 0% B13.60 I Deferral Permissible B-N-3 27 0 0% 0% B13.70 27 . Deferral Permissible Baseline performed on 24 new welds in the 1't period. B-) 3 0 0% 0% 25% will be performed in the next two periods. __ Deferral Permissible. B14.10 3 0 0% 0% B-P System leakage tests are performed each outage (IWB-5220) in accordance with plant procedures. B-Q Steam Generator tubing is examined in accordance with Plant Technical Specifications.

Page 3 of 4 Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) Credited (o) Remarks the Interval the Period for the period _ Interval the C-A 7 2 100% 28.5% CIA1 4 C1.20 4 C1.30 1 C-B 7 0 0% 0% C-1B total does not include C2.33 items that are ____ ___ ___ _ __ ___ ___ ___ ___ ___ ___ ___ required each period C2.21 3 C2.22 2 C2.31 2 C2.33 6 . _VT examinations required each period C-C 9 2 100% 22.2% C3.10 1 _ C3.20 8 C-F-1 52 16 100% 30.7% C5.11 22 C5.21 13 C5.30 14 C5.41 3 7100% 25% Less than 28 welds would be required if 7.5% criteria C--2 28 72is followed, FPL raised the total count to 28 per note 2. C5.51 22 C5.81 6 C-H System pressure tests are performed in accordance w th plant procedure,. Quantification of the number of tests is not practical. D-A 15 3 100% 20% D1.10 4 _ D1.20 11I D-B System pressure tests are perform d in accordance w ith plant procedures. Quantification of the number of tests is not practical. (IWE) E-A 4 1 100% 50% Currently in the 2n period for IWE. 100% General (I Exam required each period (IWE) E-D 6 2 100% 66.67% RR 26, Currently in the 2nd period of IWE. Includes __________ __________ ___________exam of 1/3 of moisture barrier. Examination of 8 of

Page 4 of 4 Total Total Total Total Examination Examinations Examinations Examinations Examinations Category/Item Required for Credited for Credited (%) Credited (%) Remarks the Interval the Period for the period Interval the total items required if made accessible. Deferral permissible. (IWE) E-G 14 5 100% 64.2% RR 22, Currently in the 2nd period of IWE, deferral ___ ___ ______ ___perm ___ ___ issible. F-A 122 36 100% 29.5% F1.10 40 F1.20 34 Fl.30 31 FI.40 17 R-A total does not include item R1.12. RR4 is being R-A 20 3 15% 15% submitted to implement a risk informed inspection program. The selections in program are based on the Risk Informed Program approval on August 1, 2003. RL.11 20 R1.12 129 Visual examination is performed each outage

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE Summary of Inservice Inspection Examinations 3 rd Interval Closeout Attachment 1

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 1 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASE STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARTS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-M-4000) 000100 4-WER-1 B-A C UT 51-5064915-00 ' 5/1/05 thru 5/8/05 - UT FLANGE TO UPPER SHELL B1.30 2L2.2SCIR 2005-TP4-010 X Complete from vessel side. 7L2.25CIR 2005-TP4-011 x Seven (7) acceptable 12L2.25CIR 2005-TP4-012 I indications were recorded. Total of 71% CRV was achieved when scanning from the top of the flange and from the vessel. Limitations noted were the keyways and irradiation slots. 5/14/05 - UT Complete from flange side. Geometric indications from monitor taps at 47 deg. and 137 deg.

                                                                                                                                                             **UT-1,       UT-14**

000200 4-WR-33 B-A C UT 51-5064915-00 X - - - 5/1/05 thru 5/8/05 - UT UPPER SHELL TO Bl.ll Complete. No recordable INTERMEDIATE SHELL indications. 100% CRV achieved. **UT-1** 000300 4-WR-10 B-A C UT 51-5064915-00 - X - - 5/1/05 thru 5/8/05 - UT INTERMEDIATE SHELL TO Bl11 Complete. Eleven (11) LOWER SHELL acceptable indications were recorded. 100% CRV achieved. **UT-1** 000400 4-WR-31 B-A C UT 51-5064915-00 X - - - 5/1/05 thru 5/8/05 - UT LOWER SHELL TO LOWER Bl.ll Complete. No recordable HEAD RING indications. >90% CRV achieved. Scan limitation due to guide lugs **UT-1, UT-3**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 2 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME -STATUS N I 0 SEC. XiI O NG T

SUMMARY

EXAMINATION AREA CATEGY EXAM R S E H REMARKS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET # C C M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 000600 4-WR-9 B-A C UT 51-S064915-00 - X - - 5/1/05 thru 5/8/05 - UT LOWER HEAD RING TO B1.21 Complete. One (1) BOTTOM READ acceptable indication was recorded. 83% CRV achieved. Scan limitations due to incores. **UT-1, UT-3** 000700 4-DI-A B-D C UT 51-5064915-00 - X - - 5/1/05 thru 5/8/05 - UT INLET NOZZLE TO SHELL B3.90 Complete. Six (6) e 80 DEGREES acceptable subsurface indications due to fabrication anomolies were recorded. >95% CRV achieved. Scan limitation due to nozzle boss. **UT-1** 000800 4-DO-A B-D C UT 51-5064915-00 - X - - 5/1/05 thru 5/8/05 - UT OUTLET NOZZLE TO SHELL B3.90 Complete. Seven (7) e 130 DEGREES acceptable subsurface indications due to fabrication anomolies were recorded. >90% CRV achieved. Scan limitation due to outlet nozzle boss.

                                                                                                                                 **UT-1, UT-15**

000900 4-DI-C B-D C UT 51-5064915-00 - X - - 5/1/05 thru 5/8/05 - UT INLET NOZZLE TO SHELL B3.90 Complete. Twelve (12) e 200 DEGREES acceptable subsurface indications due to fabrication anomolies were recorded. >95% CRV achieved. Scan limitation due to nozzle boss. **UT-1, UT-15**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 3 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CEPAARE COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME 0STATUS N I T SEC. XI R N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 001000 4-DO-C B-D C UT 51-5064915-00 - X - - 5/1/05 thru 5/8/05 - UT OUTLET NOZZLE TO SHELL B3.90 Complete. One (1) e 250 DEGREES acceptable subsurface indication due to fabrication anomalies was recorded. >90% CRV achieved. Scan limitation due to outlet nozzle boss.

                                                                                              **UT-1,  UT-15**

001100 4-DI-B B-D C UT 51-5064915-00 - X - - 5/1/05 thru 5/8/05 - UT INLET NOZZLE TO SHELL B3.90 Complete. Two (2) Q 320 DEGREES acceptable subsurface indications due to fabrication anomolies were recorded. >95% CRV achieved. Scan limitation due to nozzle boss. **UT-1, UT-15** 001200 4-DO-B B-D C UT 51-5064915-00 - X - - 5/1/05 thru 5/8/05 - UT OUTLET NOZZLE TO SHELL B3.90 Complete. Three (3) e 10 DEGREES acceptable subsurface indications due to fabrication anomalies were recorded. >90% CRV achieved. Scan limitation due to outlet nozzle boss.

                                                                                              **UT-1,  UT-15*

DATE: 06/27/05 TURXEY POINT THIRD INTERVAL [TP41 - UNIT 4 PAGE: 4 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL 4-001 AS.E -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM R S E H REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 001300 4-DI-A-IRS B-D C ENHANCEDVT 51-5064915-00 - - - - 5/8/05 - Enhanced Visual INLET NOZZLE INNER B3.100 2005 EOC22-O0 X - - - Complete. No recordable RADIUS indications. 100% CRV achieved. **UT-32** 001400 4-DO-A-IRS B-D C ENHANCEDVT 51-5064915-00 - - - - 5/8/05 - Enhanced Visual OUTLET NOZZLE INNER B3.100 2005 EOC22-01 - X - - Complete. Acceptable RADIUS indications were recorded. Vertical gouge was found at the 6 o'clock position of the 250 deg. outlet nozzle seating surface running the entire width of the face. Also, shallow vertical gouges were found at the 4 £ 8 o'clock position of the 130 deg. outlet nozzle seating surface running the width of the face. This type of indication appears to be normal contact mating and is seen on most core barrel exams throughout the industry. Reference CR 2005-13224. 100% CRV achieved **UT-32** 001500 4-DI-C-IRS B-D C ENRANCEDVT 51-5064915-00 - - - - 5/8/05 - Enhanced Visual INLET NOZZLE INNER B3.100 2005 EOC22-01 X - - - Complete. No recordable RADIUS indications. 100% CRV achieved. **UT-32**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL ETP4] - UNIT 4 PAGE: 5 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME -STATUS N I 0 SEC. I 0 N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 001600 4-DO-C-IRS B-D C ENHANCEDVT 51-5064915-00 - - - - 5/8/05 - Enhanced Visual OUTLET NOZZLE INNER B3.100 2005 EOC22-01 - X - - Complete. Acceptable RADIUS indications were recorded. Vertical gouge was found at the 6 o'clock position of the 250 deg. outlet nozzle seating surface running the entire width of the face. Also, shallow vertical gouges were found at the 4 a 8 o'clock position of the 130 deg. outlet nozzle seating surface running the width of the face. This type of indication appears to be normal contact mating and is seen on most core barrel exams throughout the industry. Reference CR 2005-13224. 100% CRV achieved **UT-32** 001700 4-DI-B-IRS B-D C ENHANCEDVT 51-5064915-00 - - - - 5/8/05 - Enhanced Visual INLET NOZZLE INNER B3.100 2005 EOC22-01 X - - - Complete. No recordable RADIUS indications. 100% CRV achieved. **UT-32** 001800 4-DO-B-IRS B-D C ENHANCEDVT 51-5064915-00 - - - - 5/8/05 - Enhanced Visual OUTLET NOZZLE INNER B3.100 2005 EOC22-01 X - - - Complete. No recordable RADIUS indications. 100% CRV achieved. **UT-32**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL (TP4] - UNIT 4 PAGE: 6 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: 4 INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME STATUS N I o SEC. XI R N G T

SUMMARY

EXPMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 010025 REACTOR VESSEL B-N-1 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. No WELDS AND INTERIOR B13.10 2005 EOC22-01 X - - - recordable indications. SURFACES 010050 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No INLET FLOW IMPINGEMENT B13.70 2005 EOC22-05 X - - - recordable indications. AREAS 010060 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 & 5/4/05 - VT-3 OUTLET NOZZLES B13.70 2005 EOC22-05 X - - - Complete. No recordable INTERIOR SURFACES indications. 010070 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 & 5/4/05 - VT-3 OUTLET NOZZLES B13.70 2005 EOC22-05 X - - - Complete. No recordable EXTERIOR SURFACES indications. 010080 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/4/05 - VT-3 Complete. No UPPER SECTION EXTERIOR B13.70 2005 EOC22-05 X - - - recordable indications. SURFACES 010090 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/1/05 - VT-3 Complete. No UPPER SECTION INTERIOR B13.70 2005 EOC22-05 X - - - recordable indications. SURFACES 010100 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No LOWER SECTION EXTERIOR B13.70 2005 EOC22-05 X - - - recordable indications. SURFACES (REF. DWG. NO. 4-V01)

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 7 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPRARE COMPONENTS REACTOR PRESSURE VESSEL INTERNALS 4-001 ASME -STATS N I 0 SEC. XI O N G T R S E H

SUMMARY

EXAMINATION AREA CATEGYEXAM E I O E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 4-V01) 011706 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No CORE SUPPORT COLUMNS B13.70 2005 EOC22-07 X - - - recordable indications. 011709 REACTOR VESSEL TOP B-N-1 C VT-3 51-5064915-00 - - - - S/8/05 - VT-3 Complete. No UPPER SUPPORT PLATE B13.10 2005 EOC22-02 X - - - recordable indications. XEYWAYS 011712 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No DIFFUSER PLATE (FLOW B13.70 2005 EOC22-07 X - - - recordable indications. MIXER DEVICES) 011715 CRUCIFORM INSTR. B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No GUIDE TUBES AND B13.70 2005 EOC22-07 X - - - recordable indications. FASTENERS 011724 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No RADIAL KEYS AND CLEVIS B13.70 2005 EOC22-06 X - - - recordable indications. INSERTS 011727 SECONDARY CORE SUPPORT B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No BASE PLATE AND B13.70 2005 EOC22-07 X - - - recordable indications. STRUCTURE 011728 SECONDARY CORE SUPPORT B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No TIE PLATES B13.70 2005 EOC22-07 X - - - recordable indications. 011730 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No BY-PASS FLOW NOZZLES B13.70 2005 EOC22-06 X - - - recordable indications.

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP41 - UNIT 4 PAGE: 8 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL INTERNALS 4-001 ASME TATUS N I T SEC. XI 1 RSEHG

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO l METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 4-V01) 011733 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No VESSEL TO HEAD B13.70 2005 EOC22-06 X - - - recordable indications. ALIGNMENT PINS 011745 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/1/05 - VT-3 Complete. No BAFFLE BOLTS AND B13.70 2005 EOC22-05 X - - - recordable indications. LOCKING DEVICES 011746 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/l/05 - VT-3 Complete. No BAFFLE PLATES B13.70 2005 EOC22-05 X - - - recordable indications. 011747 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/1/05 - VT-3 Complete. No TOP FORMER PLATE B13.70 2005 EOC22-05 X - - - recordable indications. 011748 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No LOWER SUPPORT PLATE B13.70 2005 EOC22-07 X - - - recordable indications. 011751 LOWER CORE PLATE B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No PLATE, COLUMN 313.70 2005 EOC22-07 X - - - recordable indications. BOLTING,GUIDE TUBE BOLTING 011753 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No SUPPORT FLANGE, B13.70 2005 EOC22-06 X - - - recordable indications. SEATING SURFACES, PLUGS

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 9 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL INTERNALS 4-001 ASME -STATUS N I T SEC. XI N EG T

SUMMARY

EXAMINATION AREA CATEGY EXAM EI REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 4-V01) 011755 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No HOLD DOWN SPRING B13.70 2005 EOC22-06 X - - - recordable indications. 011763 IRRADIATION SPECIMEN B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. CAPSULES AND B13.70 2005 EOC22-04 - X - - Acceptable indications were ATTACHMENT WELDS recorded. Capsule at 30 deg. - Gouges were seen located near the bottom of the capsule about two feet in length running vertically. Also, another area of gouging was noted at the very bottom on the tapered shoe running in the horizontal direction. Capsule at 230 deg, - Gouges were seen located near the bottom on one side of the capsue running vertically for the entire length. Also, in numereous places along the base material, chafing was seen and peeling along the outside edges of the gouge were also observed. Capsule at 270 deg. - Gouges were located abour 1/4 rd down from top of capsule running in teh horizontal dire tion for about half the width of the capsule. Reference 2005-132331

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 10 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL INTERNALS 4-001 ASME TATUS N I 0 SEC. XI O N G T R S E H

SUMMARY

EXAMINATION AREA CATEGYEXAM REMARKS E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R * *CALIBRATION BLOCK** (REF. DWG. NO. 4-V01) 011765 IRRADIATION SPECIMEN B-N-3 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. CAPSULE SLOTS B13.70 2005 EOC22-03 - X - Acceptable indications were recorded. Capsule at 30 deg. - Gouges were seen located near the bottom of the capsule about two feet in length running vertically. Also, another area of gouging was noted at the very bottom on the tapered shoe running in the horizontal direction. Capsule at 230 deg, - Gouges were seen located near the bottom on one side of the capsue running vertically for the entire length. Also, in numereous places along the base material, chafing was seen and peeling along the outside edges of the gouge were also observed. Capsule at 270 deg. - Gouges were located abour 1/4 rd down from top of capsule running in teh horizontal dire tion for about half the width of the capsule. Reference 2005-132331 011766 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 a 5/4/05 - VT-3 OUTLET NOZZLE TO B13.70 2005 EOC22-04 - X - - Complete. Acceptable VESSEL SEATING indication was recorded. SURFACES Vertical gouge was found at the 6 o'clock position of the 250 deg. outlet nozzle seating surface running the entire width of the face. Also, shallow vertical gouges were found at the 4 a 8 o'clock position of the 130 deg. outlet nozzle seating surface running the width of the face. This type of indication appears

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL ETP4] - UNIT 4 PAGE: 11 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL INTERNALS 4-001 ASM STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAMR IEl S E H0 H REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET I C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 4-V01) 011766 C to be normal contact mating and is seen on most core barrel exams throughout the industry. Reference CR 2005-13224. 011775 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/4/05 - VT-3 Complete. No THERMAL SHIELD & B13.70 2005 EOC22-04 X - - - recordable indications. ATTACHMENTS AT BOTTOM 011776 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/4/05 - VT-3 Complete. No UPPER THERMAL SHIELD B13.70 2005 EOC22-04 X - - - recordable indications. BOLTING/PINS 011777 CORE SUPPORT BARREL B-N-3 C VT-3 51-5064915-00 - - - - 5/2/05 - VT-3 Complete. No LOWER THERMAL SHIELD B13.70 2005 EOC22-06 X - - - recordable indications. BOLTING/PINS 011778 REACTOR VESSEL B-N-2 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. No RADIAL SUPPORT B13.60 2005 EOC22-02 X - - - recordable indications. KEYWAYS 011781 VESSEL INSTRUMENTATION B-N-1 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. No LOWER BEAD & B13.10 2005 EOC22-02 X - - - recordable indications. INSTRUMENTATION GUIDE TUBE 011784 OUTLET NOZZLE TO CORE B-N-1 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. INNER RADIUS SEALING B13.10 2005 EOC22-01 - X - - Acceptable indication was SURFACE recorded. Vertical gouge was found at the 6 o'clock position of the 250 deg. outlet nozzle seating surface running the entire width of the face. Also, shallow vertical gouges were found at the 4 & 8 o'clock position of the 130 deg. outlet nozzle seating surface running the width of the face. This type of indication appears to be normal contact mating and is

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 12 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL INTERNALS 4-001 ASME STATUS N I 0 SEC. XI 0O ET

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 4-V01) 011784 C seen on most core barrel exams throughout the industry. Reference CR 2005-13224. 011786 VESSEL OUTLET NOZZLES B-N-1 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. No INTERIOR SURFACES B13.10 2005 EOC22-01 X - - - recordable indications. 011787 VESSEL INLET NOZZLES B-N-1 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. No INTERIOR SURFACES B13.10 2005 EOC22-02 X - - - recordable indications. 011791 REACTOR VESSEL B-N-1 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. No CORE SUPPORT LEDGE B13.10 2005 EOC22-02 X - - - recordable indications. SURFACES (REF. DWG. NO. 5614-M-4000) 011793 VESSEL TO CLOSURE HEAD B-N-1 C VT-3 51-5064915-00 - - - - 5/8/05 - VT-3 Complete. No MATING SURFACE ON B13.10 2005 EOC22-02 X - - - recordable indications. VESSEL (REF. DWG. NO. 5614-M-4001) 041000 4-LIG-1 THRU 20 B-G-1 C UT 51-5064915-00 - - - - 5/14/05 - UT Complete. No THREADS IN FLANGE B6.40 2005-TP4-019 - - - - recordable indications. OLIO MHZ X - Limited examination close to vessel edge due to seal surface. Total coverage obtained for ligaments is 84.67%. **VT-14**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 13 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR PRESSURE VESSEL 4-001 0 ASME -STATUS N I SEC. XI 0ON G T R S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 REMARKS E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4001) 042000 4-LIG-21 THRU 40 B-G-1 C UT 51-5064915-00 - - - - 5/14/05 - UT Complete. No THREADS IN FLANGE B6.40 2005-TP4-019 - - - - recordable indications. OL10 MHZ Limited examination close to X - - vessel edge due to seal surface. Total coverage obtained for ligaments is 84.67%. **UT-14** 043000 4-LIG-41 THRU 58 B-G-1 C UT 51-5064915-00 - - - - 5/14/05 - UT Complete. No THREADS IN FLANGE B6.40 2005-TP4-019 - - - - recordable indications. OLIO MHZ I - - - Limited examination close to vessel edge due to seal surface. Total coverage obtained for ligaments is 84.67%. **UT-14**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 14 REVISION: 4 XNSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPRARE COMPONENTS REACTOR COOLANT SYSTEM LOOP A COLD LEG 4-009 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-766-S SH. 1) 057500 27.5"-RCS-1407-14 R-A C UT 51-5064915-00 X - - - 5/5/1/05 thru 5/8/05 - UT ELBOW TO RPV NOZZLE R1. 11 Complete. No recordable indications. 100% CRV achieved. Examination performed from the ID by Framatome **UT-26R, UT-32**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4J - UNIT 4 PAGE: 15 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR COOLANT SYSTEM LOOP B HOT LEG 4-011 ASME STATUS N I 0 SEC. XI _ O N G T R S EH REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET #C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-766-S SH. 2) 058800 29"-RCS-1405-2 R-A C UT 5.4-007 - - - - 4/19/05 - UT Complete. Root PIPE TO PIPE R1.11 45S2.25AX - - X - geometry recorded. Scan 45S2.25CIR - - X - limitation due to branch connection for 2.6" on downstream side. **UT-12, UT-46**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL ITP4] - UNIT 4 PAGE: 16 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR COOLANT SYSTEM LOOP C HOT LEG 4-014 ASME TATUS N I 0

        -04SEC.                            XI                                        O N   G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-766-S SH. 3) 060900 29"-RCS-1408-1 R-A C UT 51-5064915-00 X - - - 5/1/05 thru 5/8/05 - UT RPV NOZZLE TO PIPE RP1.11 Complete. No recordable indications. 100% CRV achieved. Examination performed from the ID by Framatome **UT-12, UT-32, UT-46**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL ETP4] - UNIT 4 PAGE: 17 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 1 CXPBARE COMPONENTS REACTOR COOLANT PUMP C 4-058 ASME -STATUS N I 0 SEC. XII ON G T I R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4008) 198400 4-RCP-C-A B-L-1 C VT-1 4.1-014 X - - - 4/26/05 - VT-i Complete. No PUMP CASING WELD A B12.10 recordable indications. 198500 4-RCP-C-B B-L-1 C VT-1 4.1-015 X - - - 4/26/05 - VT-i Complete. No PUMP CASING WELD B B12.10 recordable indications. 198600 4-RCP-C-C B-L-1 C VT-1 4.1-016 X - - - 4/26/05 - VT-1 Complete. No PUMP CASING MELD C B12.10 recordable indications. 199250 4-RCP-C-Li THRU L3 IA B-K C PT 3.3-011 X - - - 4/26/05 - PT Complete. No INTEGRAL ATTACHMENT B10.20 recordable indications.

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 18 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 2 CXPBARE COMPONENTS MAIN STEAM SYSTEM LOOP A OUTSIDE CONTAINMENT M.-S AME TATUJS N I 0 SEC. XII s ET REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET I C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-562-S SH. 2) 263200 14"-MSA-2402-1 C-F-2 C MT 2.2-002 X - - - 4/16/05 - PT Complete. No 12" WELDOLET TO PIPE C5.51 RS 9.3-001 X - - - recordable indications. 4/17/05 - RT Complete. No recordable indications.

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP41 - UNIT 4 PAGE: 19 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 2 CXPBARE COMPONENTS STEAM GENERATOR B BLOWDOWN INSIDE CONTAINMENT 4-106 ASME -TATUS N I 0 N G T SEC. XI 0 I R S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 REMARXS E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-791-S SH. 1) 273800 6"-BDB-2402-ll C-F-2 C MT 2.2-007 4/28/05 - MT Complete. No ELBOW TO PIPE C5.51 UT 5.2-005 recordable indications. 45S2.25AX 4/28/05 - UT Complete. Root 45S2.25CIR 60S2.25AX X geometry recorded. **UT-22** 6052.25AX X 273900 6"-BDB-2402-12 C-F-2 C MT 2.2-007 - - - - 4/28/05 - MT Complete. No PIPE TO ELBOW C5.51 UT 5.2-005 - - - - recordable indications. 45S2.25AX X - - - 4/28/05 - UT Complete. Root 45S2.25CIR X - - - 60S2.25AX - - X _ geometry recorded. **UT-22** 70S2.25AX - - X -

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP4] - UNIT 4 PAGE: 20 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 2 CXPBARE COMPONENTS MAIN FEEDWATER SYSTEM LOOP A 4-111 ASME -STATUS N I 0 SEC. XI O N G T R S EH REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET J C G MR **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-557-S SH. 1) 282600 14"-FWA-2401-20 C-F-2 C MT 2.2-003 X 4/20/05 - MT Complete. No PIPE TO ELBOW C5.51 UT 5.2-003 recordable indications. 45S2.25CIR x Undercut was observed on the 70S2.25AX X upstream toe. 4/28/05 - UT Complete. BAcking ring recorded. **UT-20**

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP41 - UNIT 4 PAGE: 21 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 2 CXPBARE COMPONENTS MAIN FEEDWATER SYSTEM LOOP C 4-113 ASME STATUS N I 0 SEC. XI _ O N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METEHOD DATA SHEET J C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-789-S SH. 1) 288160 CONT. PENETRATION C-C C MT 2.2-005 X - - - 4/22/05 - MT Complete. No INTEGRAL ATTACHMENT C3.20 recordable indications.

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP41 - UNIT 4 PAGE: 22 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 2 CXPBARE COMPONENTS MAIN FEEDWATER BYPASS LOOP A 4-114 ASME .- STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCX** (REF. DWG. NO. 5614-P-770-S SH. 3) 290150 7884-R-014-01 1A C-C C MT 2.2-001 X - - - 4/13/05 - MT Complete. No INTEGRAL ATTACHMENTS C3.20 recordable indications.

DATE: 06/27/05 TURKEY POINT THIRD INTERVAL [TP41 - UNIT 4 PAGE: 23 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 3, PERIOD 3, OUTAGE 3 (2005) CLASS 3 CXPBARE COMPONENTS INTAKE COOLING WATER TO CCW HEAT EXCHANGERS A _1 r M

SUMMARY

        %-Lu EXAMINATION AREA SME SEC. XI CATEGY r STATUS EXAM N

E I S I ET 0 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-542-S SH. 2) 328980 STRAINER A F-A C VT-3 NDE 4.3 WELDED STANCHION F1.40 328890 Strainer A IA D-A C VT-1 NDE 4.1 INTEGRAL ATTACHMENTS D1.10

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE Summary of Inservice Inspection Examinations 4 th Interval - 1 St Period Attachment 2

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: l REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME -STATUS N I O SEC. XI NS G S

SUMMARY

EXAMINATION AREA CATEGY EXAM R S E H RM4ARXS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET I C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 001900 4-WH-12 B-A R MT NDE 2.2 **UT-2** FLANGE TO DOME WELD B1.40 UT NDE 5.1 011795 VESSEL TO CLOSURE HEAD B-N-i R VT-3 NDE 4.3 MATING SURFACE ON HEAD B13.10 011796 VESSEL TO CLOSURE HEAD B-N-1 B VT-3 4.3-043 - - - X 2/25/05 - VT-3 Complete. A MATING SURFACE ON HEAD 813.10 rounded indication was observed on the surface of the inner groove at stud location #6. The dimension of the indication is .027" x

                                                                                                                            .015". Reference CR 2005-6129.

043500 4-LIFTINGLUG-1 B-K B PT 54-ISI-240 S - - - 12/29/04 - PT Complete. No LIFTING LUG AT 60 B10.10 recordable indications. DEGREES 043510 4-LIFTINGLUG-2 B-K B PT 54-ISI-240 - X - - 12/29/04 - PT Complete. LIFTING LUG AT 180 B10.10 Observed 2 rounded 3/16" DEGREES indications on downstream side of weld toe. Evaluated by FANP condition report 2005-10. Indications are acceptable. 043520 4-LIFTINGLUG-3 B-K B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No LIFTING LUG AT 300 B10.10 recordable indications. DEGREES

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 2 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME TATUS N I 0 SEC. XI O N G T R S EH REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 043530 4-SUPPORTLUG-1 B-K B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No LIFTING LUG AT 0 B10.10 recordable indications. DEGREES 043540 4-SUPPORTLUG-2 B-K B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No LIFTING LUG AT 120 B10.10 recordable indications. DEGREES 043550 4-SUPPORTLUG-3 B-K B PT 54-ISI-240 - X - - 12/29/04 - PT Complete. LIFTING LUG AT 240 B10.10 Observed 1 rounded 3/32" and DEGREES one linear 1/8" indications on downstream side of weld toe. Evaluated by FANP condition report 2005-10. Indications are acceptable. 044000 4-WH-14-1 THRU 65 B-0 R PT NDE 3.3 CRDM HOUSING WELDS B14.10 044050 4-CRDM-59 (PS) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044060 4-CRDM-64 (P6) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044070 4-CRDH-32 (M6) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 3 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4000) 044080 4-CRDM-27 (L5) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044090 4-CRDM-53 (L3) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044100 4-CRDM-65 (K2) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044110 4-CRDM-60 (R2) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044120 4-CRDM-66 (F2) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044130 4-CRDM-34 (F4) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044140 4-CRDM-28 (E5) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044150 4-CRDM-55 (C5) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 4 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CP8EAR COMPONENTS REACTOR PRESSURE VESSEL 4-UU1 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METROD DATA SHEET # C G M R **CALIBRATION BLOCK*" (REF. DWG. NO. 5614-M-4000) 044160 4-CRDM-67 (B6) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044170 4-CRDM-61 (B8) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044180 4-CRDM-69 (910) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044190 4-CRDM-36 (D10) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044200 4-CRDM-29 (Ell) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044210 4-CRDM-57 (E13) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044220 4-CRDM-69 (F14) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044230 4-CRDM-58 (H14) B-a B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 5 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR PRESSURE VESSEL 4-001 ASME TATUS N I 0 SEC. XI ION G T

SUMMARY

EXAMINATION AREA CATEGY EXAM R I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET # C G M R "*CALIBRATION BLOCK"* (REF. DWG. NO. 5614-M-4000) 044240 4-CRDM-62 (K14) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044250 4-CRDM-30 (K12) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044260 4-CRDM-26 (Lll) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044270 4-CRDM-51 (Nll) B-O B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 044280 4-CRDM-63 (P10) B-0 B PT 54-ISI-240 X - - - 12/29/04 - PT Complete. No CRDM HOUSING WELDS B14.10 recordable indications. 045000 CONTROL ROD DRIVE BP R VT-2 NDE 4.2 B15.10 046000 INSTRUMENTATION B-P R VT-2 NDE 4.2 B15.10

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 6 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS STEAM GENERATOR A PRIMARY SIDE 4-003 ASME -STATUS N I 0 SEC. XI O N G T R S EH REMARXS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G MR **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4003) 050800 4-SGA-Z B-B C UT 5.1-001 - - - - 4/27/05 - UT Complete. HEAD TO TUBESHEET WELD B2.40 OL2.25 - - - X Previously accepted 45S2.25AX - - - X inclusions were record. 45S2.25CIR - - -x 60S2.25AX - - - X **UT_8** 60S2.25CIR - - - X

DATE: 06/27/05 TUR2EY POINT - UNIT 4 PAGE: 7 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS PRESSURIZER 4-006 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM R S E H REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4002 SH.1) 055500 4-PZR-1 THRU 16 B-G-2 C VT-1 4.1-003 X - - - 4/13/05 - VT-1 Complete. No PRESSURIZER MANWAY B7.20 recordable indications BOLTING

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 8 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR COOLANT SYSTEM LOOP A INTERMEDIATE LEG 4-007 ASME -STATUS NI 0 SEC. XI ON G T RS E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM EI 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # CG H R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-766-S SH. 1) 056200 31"-RCS-1401-9 R-A C UT NDE 5.4-006 - - - - 4/19/05 - UT Complete. No PIPE TO ELBOW R1.11 45S2.25AX X - - - recordable indications. 45S2.2SCIR X - - -

                                                                                           **UT-12, UT-26R, UT-46**

NDE 5.23-001 45L1,.00AX X - - - 45L1.00CIR X - - -

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 9 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBZAR COMPONENTS REACTOR COOLANT SYSTEM LOOP A HOT LEG 4-008 ASME TATUS N I T SEC. XII0 RS H

SUMMARY

EXAMINATION AREA CATEGY E E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO l METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-766-S SH. 1) 056700 29"-RCS-1404-2 R-A C UT 5.4-010 - - - - 4/26/05 - UT Complete. Root PIPE TO PIPE R1.11 45S2.25AX - - X - geometry recorded. **UT-12, 45S2.25CIR UT-46** 60S2.25AX X - - -

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 10 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR COOLANT SYSTEM LOOP A COLD LEG 4-009 ASME -STATUS N I 0 SEC. XI ONG T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-766-S SR. 1) 057800 27.5"-RCS-1407-21 R-A C VT-2 4.2-002 X - - - 4/10/05 - VT-2 Complete. No 2" BRANCH CONNECTION R1.12 Recordable Indications 057820 27.5"-RCS-1407-24 R-A C VT-2 4.2-002 X - - - 4/10/05 - VT-2 Complete. No BRANCH CONNECTION TO R1.12 Recordable Indications INST. CONNECTION

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 11 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR COOLANT LOOP A DRAIN 4-026 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DwG. NO. 5614-P-577-S SH. 1) 082700 2"-RC-1401-1 R-A C VT-2 4.2-003 X - - - 4/10/05 - VT-2 Complete. No BRANCH CONNECTION TO R1.12 Recordable Indications PIPE 082800 2"-RC-1401-2 R-A C VT-2 4.2-003 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 082900 2'-RC-1401-3 R-A C VT-2 4.2-003 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 083000 2"-RC-1401-4 R-A C VT-2 4.2-003 X - - - 4/10/05 - VT-2 Complete. No PIPE TO TEE R1.12 Recordable Indications 083100 2"-RC-1401-5 R-A C VT-2 4.2-003 X - - - 4/10/05 - VT-2 Complete. No TEE TO REDUCING INSERT R1.12 Recordable Indications 083200 2"-RC-1401-6 R-A C VT-2 4.2-003 X - - - 4/10/05 - VT-2 Complete. No TEE TO PIPE R1.12 Recordable Indications 083300 2"-RC-1401-7 R-A C VT-2 4.2-003 X - - - 4/10/05 - VT-2 Complete. No PIPE TO VALVE 4-508A R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 12 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: 4 INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR COOLANT LOOP B DRAIN 4-027 ASME STATUS N I 0 SEC. XI O N GT

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-577-S SH. 2) 083500 2"-RC-1402-1 R-A C VT-2 4.2-004 X - - - 4/10/05 - VT-2 Complete. No BRANCH CONNECTION TO R1.12 Recordable Indications PIPE 083600 2"-RC-1402-2 R-A C VT-2 4.2-004 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 083700 2"-RC-1402-3 R-A C VT-2 4.2-004 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 083800 2"-RC-1402-4 R-A C VT-2 4.2-004 X - - - 4/10/05 - VT-2 Complete. No PIPE TO VALVE 4-515A R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 13 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR COOLANT LOOP C DRAIN 4-028 ASME -STATUS N I G SEC. XI NS G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCX** (REF. DWG. NO. 5614-P-577-S SH. 3) 084100 2"-RC-1403-1 R-A C VT-2 4.2-005 X - - - 4/10/05 - VT-2 Complete. No BRANCH CONNECTION TO R1.12 Recordable Indications PIPE 084200 2"-RC-1403-2 R-A C VT-2 4.2-005 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 084300 2"-RC-1403-3 R-A C VT-2 4.2-005 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 084400 2"-RC-1403-4 R-A C VT-2 4.2-005 X - - - 4/10/05 - VT-2 Complete. No PIPE TO VALVE 4-505A R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 14 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS CHEMICAL AND VOLUME CONTROL AUXILIARY SPRAY LINE 4-035 ASME _STATUS N I 0 SEC. XI O N G T R S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM REMARXS E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET J C G MR **CQLIBRATION BLOCX** (REF. DWG. NO. 5614-P-782-S SH. 1) 111500 2"-RC-1410-33 R-A C VT-2 4.2-012 X - - - 6/4/05 - VT-2 Complete. No VALVE 4-313 TO PIPE R1.12 recordable indications

                                                                                         **UT-54**

111600 2"-RC-1410-34 R-A C VT-2 4.2-012 X - - - 6/4/05 - VT-2 Complete. No PIPE TO TEE R1.12 recordable indications

                                                                                         **UT-54**

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 15 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL FROM RCS LOOP A HOT LEG 4-036 ASME STATUS N I 0 SEC. XI ON G T

SUMMARY

EXAMINATION AREA CATEGY EXAM R S E H REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET

  • C G M R **CALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-574-S SH. 1) 115300 MOV-4-750 B-M-2 C VT-3 4.3-032 X - - - 4/21/05 - VT-3 Complete. No VALVE INTERNAL SURFACE B12.50 Recordable Indications. 115400 MOV-4-750 BOLTING B-G-2 C VT-1 4.1-007 - - - X 4/21/05 - VT-1 Complete. VALVE BOLTING B7.70 4.1-008 X - - - Valve nut #13 and #2 stud was galled. Valve nut #21 and #13 stud was frozen together. 4/22/05 - VT-l Complete. Preservice examination of new studs and nuts. Reference CR 2005-12007 115650 4-ACH-180 F-A C VT-3 4.3-014 X - - - 4/13/05 - VT-3 Complete. No DOUBLE ACTING F1.10 Recordable Indications. RESTRAINT 116430 PS-3 F-A C VT-3 4.3-026 - - - X 4/20/05 - VT-3 Complete. DOUBLE ACTING F1.10 4.3-026A - - - X Field verified clearances RESTRAINT differ from drawing. Actual field clearances are 1/16 inch on the top and 1/8 inch on the bottom lugs on the wall plate side instead of 1/16 inch and 1/8 inch on top and bottom on the opposite side instead of 0 inches. Also, chaffing was observed on the top tube steel on the lug closes to the wall plate. Note: Drawing discrepancy - Lugs are welded on three sides instead of all the way around as shown on the as-built. Engineering Disposition - Use As-is. Reference CR 2005-11852. 4/28/2005 - Additional measurements taken for engineering using filler gauges.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 16 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL FROM RCS LOOP A HOT LEG 4-036 ASME TATUS N I 0 SEC. XI O N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EM AM E I O E NUMBER IDENTIFICATION ITEM NO METE'HOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-574-S SH. 1) 116430 C 116470 PS-3 IA B-K C PT 3.3-008 X - - - 4/20/05 - PT Complete. No INTEGRAL ATTACHMENTS B10.20 recordable indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 17 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL TO RCS LOOP A COLD LEG 4-037 ASME -STATUS N I 0 SEC. XI ION SE. IR S GE TH

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-509-S SH. 1) 119150 8073-H-825-01 F-A C VT-3 4.3-011 X - - - 4/13/05 - VT-3 Complete. No DOUBLE ACTING F1.10 Recordable Indications. RESTRAINT 119450 SR-450C F-A C VT-3 4.3-015 - - - X 4/13/05 - VT-3 Complete. SPRING HANGER F1.10 4.3-041 X - - - Spring can setting is out of tolerance. Engineering disposition - Reset spring can setting to cold position. 4/28/2005 - Re-examiantion after corrective action per CR 2005-10974 120650 10"-SI-1401-21 R-A C UT 5.4-008 - - - - 4/21/05 - UT Complete. No ELBOW TO ELBOW Rl.ll 45S2.25CIR X - - - recordable indications. 60S2.25AX X - - - **UT-27**

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 18 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBF.AR COMPONENTS RESIDUAL HEAT REMOVAL TO RCS LOOP C COLD LEG 4-039 ASME ATS N I 0 SEC. XI O N G T R S EH REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-509-S SH. 4) 124940 SR-449 F-A C VT-3 4.3-012 X - - - 4/13/05 - VT-3 Complete. No SPRING HANGER Fl.10 Recordable Indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 19 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP A INSIDE CTMT 4-040 ASME _STATUS N I 0 SEC. XI O N G T R S E H A REXARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G M R **CALIBRATION BLOCR** (REF. DWG. NO. 5614-P-512-S SH. 1) 128100 2"-SI-1401-1 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No VALVE 4-873A TO PIPE R1. 12 recordable indications. 128200 2"-SI-1401-2 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 recordable indications. 128300 2"-SI-1401-3 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 recordable indications. 128400 2"-SI-1401-4 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO TEE R1.12 recordable indications. 128450 2"-SI-1401-5 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No TEE TO REDUCING INSERT R1.12 recordable indications. 128500 2"-SI-1401-6 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No TEE TO PIPE R1.12 recordable indications. 128600 2"-SI-1401-7 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO VALVE 4-868A R1.12 recordable indications. 128700 2"-SI-1401-8 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No VALVE 4-868A TO PIPE R1.12 recordable indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 20 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP A INSIDE CTHT 4-040 ASME -STATUS N I 0 SEC. x I N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-512-S SH. 1) 128800 2"-SI-1401-9 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW Rl.12 recordable indications. 128900 2"-SI-1401-10 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 recordable indications. 129000 2"-SI-1401-1l R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO COUPLING R1.12 recordable indications. 129100 2"-SX-1401-12 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No COUPLING TO PIPE R1.12 recordable indications. (REF. DWG. NO. 5614-P-512-S SH. 2) 129200 2"-SI-1401-13 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO COUPLING RI.12 recordable indications. 129300 2"-SI-1401-14 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No COUPLING TO PIPE R1.12 recordable indications. 129340 WR-5 F-A C VT-3 4.3-040 X - - - 4/26/05 - VT-3 Complete. No DOUBLE ACTING F1.10 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 21 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP A INSIDE CTMT 4-040 ASME TATUS N I 0 SEC. XI R S EG

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R *"CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-512-S SR. 2) 129400 2"-SI-1401-15 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW Rl.12 recordable indications. 129500 2"-SI-1401-16 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 recordable indications. 129600 2'-SI-1401-17 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 recordable indications. 129700 2"-SI-1401-18 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE Rl.12 recordable indications. 129800 2"-SI-1401-19 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 recordable indications. 129900 2"-SI-1401-20 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE EL.12 recordable indications. 129930 2"-SI-1401-32 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO TEE R1.12 Recordable Indications 129950 2"-SI-1401-33 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No TEE TO REDUCING INSERT R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 22 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP A INSIDE CTMT 4-040 ASHE -STATUS N I 0 SEC. XI I N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-512-S SH. 2) 129970 2'-SI-1401-34 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No TEE TO PIPE R1.12 Recordable Indications 130000 2'-SI-1401-21 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 130100 2"-SI-1401-22 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 130200 2"-SI-1401-23 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 130300 2"-SI-1401-24 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 130400 2"-SI-1401-25 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO COUPLING R1.12 Recordable Indications 130500 2"-SI-1401-26 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No COUPLING TO PIPE R1.12 Recordable Indications 130600 2"-SI-1401-27 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 23 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP A INSIDE CTMT 4-040 ASME 0 G O ISTATUS SEC. XI N EG T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMRKS NUMBER IDENTIFICATION ITEM NO MZTHOD DATA SHEET # C G M R * *CALIBRATION BLOCZK* * (REF. DWG. NO. 5614-P-512-S SH. 2) 130700 2"-SI-1401-28 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 130800 2"-SI-1401-29 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 130900 2"-SI-1401-30 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 131000 2"-SI-1401-31 R-A C VT-2 4.2-006 X - - - 4/10/05 - VT-2 Complete. No PIPE TO BRANCH R1.12 Recordable Indications CONNECTION

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 24 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP B INSIDE CTMT 4-041 ASE ,TATUS N I 0 SEC. X ii N GT

SUMMARY

EXAMINATION AREA CATEGYX E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET # C G H R "*CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-513-S SH. 1) 132400 2"-SI-1402-1 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No VALVE 4-873B TO PIPE R1.12 Recordable Indications 132500 2"-SI-1402-2 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO TEE R1.12 Recordable Indications 132550 2"-SI-1402-3 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No TEE TO REDUCING INSERT R1.12 Recordable Indications 132600 2"-SI-1402-4 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No TEE TO PIPE R1.12 Recordable Indications 132700 2"-SI-1402-5 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO VALVE 4-868B R1.12 Recordable Indications 132800 2"-SI-1402-6 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No VALVE 4-868B TO PIPE R1.12 Recordable Indications 132900 2"-SI-1402-7 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 133000 2"-SI-1402-8 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 25 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP B INSIDE CTMT 4-041 ASME -STATUS N I 0 SEC. XI ION G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-513-S SH. 1) 133100 2"-SI-1402-9 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 133200 2"-SI-1402-10 R-A C VT-2 4.2-007 S - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 133300 2"-SI-1402-38 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO TEE R.1.12 Recordable Indications 133350 2"-SI-1402-39 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No TEE TO REDUCING INSERT R1.12 Recordable Indications 133400 2"-SI-1402-40 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No TEE TO PIPE R1.12 Recordable Indications 133500 2"-SI-1402-11 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 133600 2"-SI-1402-12 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 133700 2"-SI-1402-13 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 26 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP B INSIDE CTMT 4-041 ASME TATS N I 0 SEC. XI O N G T R S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM REMART S E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET f C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-513-S SH. 1) 133800 2"-SI-1402-14 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 133900 2"-SI-1402-15 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 134000 2"-SI-1402-16 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 134300 2"-SI-1402-19 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 134400 2"-SI-1402-20 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 134500 2"-SI-1402-21 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 134600 2"-SI-1402-22 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 134620 2"-SI-1402-43 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R.1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 27 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP B INSIDE CTMT 4-041 AE TATUS N I 0 SEC. XI O N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXXM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-513-S SH. 1) 134630 2"-SI-1402-44 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE RP1.12 Recordable Indications 134700 2"-SI-1402-23 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO COUPLING R1.12 Recordable Indications 134800 2"-SI-1402-24 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No COUPLING TO PIPE R1.12 Recordable Indications 134900 2"-SI-1402-25 R-A C VT-2 4.2-007 S - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications (REF. DWG. NO. 5614-P-513-S SR. 2) 135000 2"-SI-1402-26 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 135100 2"-SI-1402-27 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 135200 2"-SI-1402-28 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 28 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP B INSIDE CTMT 4-041 ASME STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-513-S SH. 2) 135300 2"-SI-1402-29 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO COUPLING RI.12 Recordable Indications 135400 2"-SI-1402-30 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No COUPLING TO PIPE R1.12 Recordable Indications 135420 2"-SI-1402-41 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 135430 2"-SI-1402-42 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 135500 2"-SI-1402-31 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 135600 2"-SI-1402-32 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 135700 2"-SI-1402-33 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 135800 2"-SI-1402-34 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R.1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 29 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP B INSIDE CTMT 4-041 ASM .- STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMNRKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET 5 C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-513-S SH. 2) 135900 2"-SI-1402-35 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 136000 2"-SI-1402-36 R-A C VT-2 4.2-007 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 136100 2"-SI-1402-37 R-A C VT-2 4.2-007 S - - - 4/10/05 - VT-2 Complete. No PIPE TO BRANCH R1.12 Recordable Indications CONNECTION

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 30 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP C INSIDE CTMT 4-042 ASM STTUS N I 0 SEC. XI O NG T R SE H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAH E IO E NUMBER IDENTIFICATION ITEM NO HETHOD DATA SHEET # C GM R

  • QCALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-514-S SH. 1) 137600 2"-SI-1403-1 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No VALVE 4-873C TO PIPE R1.12 Recordable Indications 137700 2"-SI-1403-2 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 137800 2"-SI-1403-3 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 137900 2"-SI-1403-4 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO TEE R1.12 Recordable Indications 137950 2"-SI-1403-5 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No TEE TO REDUCING INSERT R1.12 Recordable Indications 138000 2"-SI-1403-6 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No TEE TO PIPE R1.12 Recordable Indications 138100 2"-SI-1403-7 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO VALVE 4-868C R1.12 Recordable Indications 138200 2"-SI-1403-8 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No VALVE 4-868C TO PIPE R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 31 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP C INSIDE CTMT 4-042 ASME TATUS N I 0 SEC. XII ON G T CATEGY EXAM IR EI S E 0 H E REMARKS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-514-S SH. 1) 138300 2"-SI-1403-9 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 138400 2"-SI-1403-10 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 138450 PS-2 F-A C VT-3 4.3-030 X - - - 4/21/05 - VT-3 Complete. No DOUBLE ACTING Fl.10 Recordable Indications. RESTRAINT 138500 2"-SI-1403-11 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 138600 2"-SI-1403-12 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 138700 21-SI-1403-13 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 138800 21-SI-1403-14 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 138900 2"-SI-1403-15 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications __ __ __ __ __ _.__ D__ _ _ _._ _ _ __ _ 1_4-S_ _ S_E_.- 2 _)_ __ __ __ __ __ __ __ _ __F __ _ __NO _ _ __-_-5 (REF. DWG. NO. 5614-P-514-S SH. 2)

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 32 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP C INSIDE CTMT 4-042 ASME -STATUS N I 0 SEC. XI SE H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-514-S SH. 2) 139000 2"-SI-1403-16 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 139100 2"-SI-1403-17 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 139200 2"-SI-1403-18 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 139300 2"-SI-1403-19 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO COUPLING R.1.2 Recordable Indications 139400 2"-SI-1403-20 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No COUPLING TO PIPE R1.12 Recordable Indications 139500 2"-SI-1403-21 R-A C VT-2 4,2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications 139600 2"-SI-1403-22 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 139700 2"-SI-1403-23 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ELBOW R1.12 Recordable Indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 33 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP C INSIDE CTMT 4-042 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-514-S SH. 2) 139800 2"-SI-1403-24 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No ELBOW TO PIPE R1.12 Recordable Indications 139900 2"-SI-1403-25 R-A C VT-2 4.2-008 X - - - 4/10/05 - VT-2 Complete. No PIPE TO BRANCH R1.12 Recordable Indications CONNECTION

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 34 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION LOOP A INSIDE CTMT 4-043 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E R ONARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-792-S SN. 2) 143040 8081-H-001-14 F-A C VT-3 4.3-016 - - - X 4/14/05 - VT-3 Complete. SPRING HANGER F1.10 4.3-042 X - - - Spring can setting is out of tolerance. Engineering disposition - Reset spring can setting to cold position. 4/28/2005 - Re-examiantion after corrective action per CR 2005-10976

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 35 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS CHEMICAL & VOLUME CONTROL TO RCS LOOP C HOT LEG 4-045 ASME -STATUS N I 0 SEC. XI O N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGYEXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-782-S SH. 2) 152650 CV-4-310B A VT-1 4.1-013 - - - X 4/24/05 - VT-1 Complete. Valve Examined one stud only for the boric acid program. Light dry boric accumulation on the stud and inside the bonnet stud hole 360 degrees. Evidence of water was observed in the valve body threads and 1 1/2" of the stud was wet. Reference WO 35009665-01. Valve was later taken apart and gasket was replaced.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 36 REVISION: 4 INSERVICE INSPECTION RESULTS SUMMARRY INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS CHEMICAL & VOLUME CONTROL TO RCS LOOP A COLD LEG 4-046 ASME ,-STATUS N I 0 SEC. XIS E H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-782-S SH. 3) 161350 SR-942 F-A C VT-3 4.3-038 X - - - 4/25/05 - VT-3 Complete. No DOUBLE ACTING F1.10 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURK.EY POINT - UNIT 4 PAGE: 37 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBE.AR COMPONENTS CHEMICAL AND VOLUME CONTROL TO REGENERATIVE HX 4-047 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-551-S SH. 1) 163050 4-VCH-63 F-A C VT-3 4.3-039 X - - - 4/25/05 - VT-3 Complete. No DOUBLE ACTING F1.10 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 38 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS CHEMICAL 4 VOLUME CONTROL SEAL INJECTION LOOP A 4-050 ASME STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-556-S SH. 1) 172650 PS-1 TYPE A F-A C VT-3 4.3-027 X - - - 4/20/05 - VT-3 Complete. No DOUBLE ACTING F1.10 Recordable Indications. RESTRAINT 174750 2'-CH-1403-FB B-G-2 C VT-1 4.1-009 X - - - 4/23/05 - VT-1 Complete. No PIPING FLANGE BOLTING B7.50 recordable indications 175500 1.5"-CH-1401-FB B-G-2 C VT-1 4.1-005 X - - - 4/15/05 - VT-1 Complete. No PIPING FLANGE BOLTING B7.50 recordable indications (REF. DWG. NO. ) 175890 3/4"-CH-1439A-l R-A C VT-2 4.2-009 X - - - 4/10/05 - VT-2 Complete. No RCP 4P-200A TO R1.12 recordable indications. CONNECTION 175892 3/4"-CH-1439A-2 R-A C VT-2 4.2-009 X - - - 4/10/05 - VT-2 Complete. No CONNECTION TO PIPE R1.12 recordable indications. 175894 3/4"-CH-1439A-3 R-A C VT-2 4.2-009 X - - - 4/10/05 - VT-2 Complete. No PIPE TO FLANGE R1.12 recordable indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 39 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS CHEMICAL 6 VOLUME CONTROL SEAL INJECTION LOOP B 4-051 ASME - STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM B I 0 8 REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. ) 180880 3/4"-CH-1440A-1 R-A C VT-2 4.2-011 - - - - 4/10/05 - VT-2 Complete. No RCP 4P-200C TO Rl.12 recordable indications. CONNECTION 180882 3/4"-CH-1440A-2 R-A C VT-2 4.2-011 X - - - 4/10/05 - VT-2 Complete. No CONNECTION TO PIPE R1.12 recordable indications. 180884 3/4"-CH-1440A-3 R-A C VT-2 4.2-011 X - - - 4/10/05 - VT-2 Complete. No PIPE TO FLANGE R1.12 recordable indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 40 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS I CPBEAR COMPONENTS CHEMICAL & VOLUME CONTROL SEAL INJECTION LOOP C 4-052 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. ) 186568 3/4"-CH-1441A-l R-A C VT-2 4.2-010 X - - - 4/10/05 - VT-2 Complete. No RCP 4P-200C TO R1.12 recordable indications. CONNECTION 186570 3/4"-CH-1441A-2 R-A C VT-2 4.2-010 X - - - 4/10/05 - VT-2 Complete. No CONNECTION TO PIPE R1.12 recordable indications. 186572 3/4"-CH-1441A-3 R-A C VT-2 4.2-010 X - - - 4/10/05 - VT-2 Complete. No PIPE TO ORIFICE R1.12 recordable indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 41 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR COOLANT PUMP 4-055 ASME STATUS N I 0 SEC. xi O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G M R "*CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4006) 195900 RCP FLYWHEEL 2S-76P499 RG 1.14 C UT 348A30-B-001 X - - - 2/11/05 - UT Complete. FLYWHEEL PT 80165-2-X-001 X - - - 2/14/05 - PT Complete

                                                                                       **FLYWHEEL**

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 42 REVISION: 4 INSERVICE INSPECTION RESULTS SUMWORY INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS REACTOR COOLANT PUMP C 4-058 ASME _STATUS N I 0 SEC. XI O N G T R SE H REMART S

SUMMARY

EXAMINATION AREA CATEGY EXAM E IO E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C GM R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4008 SH.1) 198700 4-RCP-C-PUMP CASING B-L-2 P VT-3 NDE 4.3 05 - INTERNAL SURFACES B12.20 (REF. DWG. NO. 5614-M-4008) 198800 4-RCP-FSC-1 THRU 24 B-G-1 C UT 5.8-001 - - - - 4/21/05 - UT Complete. No FLANGE STUDS B6.180 OL10.0 ZONE 1 X - - - recordable indications. OL10.0 ZONE 2 X - - Preservice examination was performed on stud #19. The original stud had thread damage in the engaged area.

                                                                                                                                  **UT-18**

198900 4-RCP-FNC-1 THRU 24 B-G-1 C VT-1 4.1-010 X - - - 4/22/05 - VT-i Complete. No FLANGE NUTS B6.200 4.1-017 X - - - recordable indications. 4/27/05 - VT-i Complete. Baseline exam on replacement nut due to mushrooming. 199000 4-RCP-FLC-l THRU 24 B-G-1 C VT-l 4.1-011 X - - - 4/21/05 - VT-i Complete. No FLANGE SURFACE B6.190 recordable indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 43 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 1 CPBEAR COMPONENTS CHEMICAL £ VOLUME CONTROL, REGENERATIVE HEAT EXCH 4-059 ASME STATUS N I 0 SEC. XI _ O N G T R S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I O E REMARIS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G H R **CALI8RASION BLOCK"* (REF. DWG. NO. 5614-M-4009 SH.1) 199290 RGX 4E200 C VT-2 4.2-001 X - - - 4/10/05 - VT-2 Complete. No VISUAL FOR LEAKAGE VT-2 4.2-013 X - - - recordable indications. Examination at Shutdown. 6/4/05 - VT-2 Complete. No recordable indications. Examination at Startup.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 44 REVISION: 4 XNSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS STEAM GENERATOR C SECONDARY SIDE 4-062 ASME STATUS N I 0 SEC. XI ORN GS

SUMMARY

EXAMINATION AREA CATEGY EX E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4005) 207900 4-SGC-SS C VT 4.4-001 X - - - 4/20/05 - VT / UT Complete. SECONDARY SIDE Performed visual for debris, EXAMINATION damage thoughout from feedring and up. Also performed visual for i-nozzle erosion with video probe close to tee and UT thickness on tee. Lowest T reading is .470" to the left side of center.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 45 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL TO RESID.HEAT REMOVAL PUMP A 4-063 ASM SATUS N I 0 SEC. XI O N G T R S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G M R *"CA1LIBRATION BLOCK** (REF. DWG. NO. 5614-P-574-S SH. 1) 208560 4-ACH-178 F-A C VT-3 4.3-025 X - - - 4/20/05 - VT-3 Complete. No DOUBLE ACTING F1.20 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 46 4 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL TO RESID.HEAT REMOVAL PUMP B 4-064 ASME - STATUS N I T SEC. XI R N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-503-S SH. 1) 211800 14"-RHR-2403-1 C-F-1 C PT 3.3-003 X - - - 4/8/05 - PT Complete. No TEE TO TEE C5.11 UT 5.4-002 - - - - recordable indications. 45S5.OCIR X - - - 4/8/05 - UT Complete. No 60S5.OAX 70S2.25AX x - - - recordable indications.

                                                                                              **UT-33**

211900 14"-RHR-2403-2 C-F-1 C PT 3.3-003 X - - - 4/8/05 - PT Complete. No TEE TO PIPE C5.11 UT 5.4-002 - - - - recordable indications. 60S5.ORX - - - 4/8/05 - UT Complete. Root 70S2.25AX x - - - geometry recorded. **UT-33** 212100 14"-RHR-2403-4 C-F-1 C PT 3.3-004 X - - - 4/8/05 - PT Complete. No ELBOW TO VALVE 4-752B C5.11 UT 5.4-002 - - - - recordable indications. 45S5.OCIR X - - - 4/8/05 - UT Complete. No 60S5.0AX X - - - 70S2.25AX x - - - recordable indications.

                                                                                              **UT-33**

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 47 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: 4 INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL INSIDE & OUTSIDE CONTAINMENT 4-069 ASME STATUS N I 0 SEC. XI _ 0 N G T R S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARRS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M **CALIBRASION BLOCK** (REF. DWG. NO. 5614-P-505-S SH. 4) 220000 12"-RHR-2402-lLU C PT 3.3-001 X 4/8/05 - PT Complete. No LONGITUDINAL SEAM WELD UT 5.4-001 recordable indications. 45S2.25AX X UPSTREAM 4/8/05 - UT Complete. No 45S2.25CIR X 60S2.25AX X recordable indications

                                                                                           **UT-35**

220100 12"-RHR-2402-1 C-F-1 C PT 3.2-001 X - - - 4/8/05 - PT Complete. No REDUCER TO PIPE C5.11 UT 5.4-001 - - - - recordable indications. 45S2.25AX X - - - 4/8/05 - UT Complete. Root 60S2.25AX - - X - geometry recorded. **UT-35** 70S2.25AX X - - - 220120 12"-RHR-2402-ILD C PT 3.3-001 X - - - 4/8/05 - PT Complete. No LONGITUDINAL SEAM WELD UT 5.4-001 - - - - recordable indications. DOWNSTREAM 45S2 .25AX X - - - 4/8/05 - UT Complete. No 45S2.25C1R X - - - 60S2.25AX X - - - recordable indications.

                                                                                           **US-35**

220240 SR-644 F-A C VT-3 4.3-003 X - - - 4/8/05 - VT-3 Complete. No DOUBLE ACTING F1.20 Recordable Indications. RESTRAINT (REF. DWG. NO. 5614-P-505-S SH. 3) 221480 12"-RER-2402-15LU C PT 3.3-002 X - - - 4/8/05 - PT Complete. No LONGITUDINAL SEAM WELD UT 5.4-001 - - - - recordable indications. 45S2.25AX X- - - 4/8/05 - UT Complete. No UPSTREAM 45S2.25CIR 60S2.25AX X - - - recordable indications.

                                                                                           **UT-35**

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 48 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL INSIDE & OUTSIDE CONTAINMENT 4-069 ASME STATUS N I 0 SEC. XI _ 0 N G T R S E H REMARXS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-505-S SR. 3) 221500 12"-RHR-2402-15 C-F-1 C PT 3.3-002 x - 4/8/05 - PT Complete. No PIPE TO FLANGE C5.11 UT 5.4-001 - recordable indications. 45S2.25AX K 4/8/05 - UT Complete. Root 45S2.2SCIR K 60S2.25AX X - geometry recorded. **UT-35** 70S2.25AX X

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 49 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL-SYSTEM INSIDE CONTAINMENT 4-084 ASME _TATUS N I 0 SEC. XI 0 N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGYEXAM B I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-509-S SH. 4) 234240 8073-H-809-05 F-A C VT-3 4.3-021 - - - X 4/15/05 - VT-3 Complete. DOUBLE ACTING F1.20 4.3-021A - - - X Field verified clearances RESTRAINT differ from drawing. Reference restraint drawing 5614-H-509 Sh. 3B R.l. Actual field clearances are 1/64" on channel iron side instead of 1/16", 7/32" on the opposite side instead of 1/16" and 1/8" on top instead of 1/16". 4/29/05 - Additional measurements taken for clearance utilizing feeler gauges for clearance measurements instead of 6" scale. Reference CR 2005-11049.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 50 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS RESIDUAL HEAT REMOVAL SYSTEM INSIDE CONTAINMENT 4-089 ASME -STATUS N I T SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-509-S SN. 1) 238950 CONT. PENETRATION P-li F-A C VT-3 4.3-034 X - - - 4/22/05 - VT-3 Complete. No ANCHOR F1.20 Recordable Indications. 238960 CONT. PENETRATION P-l1 C-C C PT 3.3-010 X - - - 4/26/05 - PT Complete. No INTEGRAL ATTACHMENT C3.20 recordable indications 239200 8"-SI-2407-1 C-F-1 C PT 3.3-009 X - - - 4/22/05 - PT Complete. No PIPE TO ELBOW C5.11 UT 5.4-009 - - - - recordable indications. 4552.25AX C - - - 4/22/05 - UT Complete. Root 45S2.25C1R K - - - 6052.25AX - - X _ geometry recorded. **UT-41** 239400 8"-SI-2407-2 C-F-1 C PT 3.3-009 X - - - 4/22/05 - PT Complete. No ELBOW TO PIPE C5.11 UT 5.4-009 - - - - recordable indications. 4552.25AX C - - - 4/22/05 - UT Complete. Root 45S2.25CIR K - - - 60S2.25AX - - X _ geometry recorded. **UT-41** 240100 4-SI8-74 F-A C VT-3 4.3-013 X - - - 4/14/05 - VT-3 Complete. No DOUBLE ACTING F1.20 Recordable Indications. RESTRAINT 240120 4-SIH-74 IA C-C C PT 3.3-012 X - - - 4/26/05 - PT Complete. No INTEGRAL ATTACHMENT C3.20 recordable indications. Light pink indications are held at toe due to undercut.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 51 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE i (05) CLASS 2 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION OUTSIDE CONTAINMENT 4-097 ASME TATUS N I 0 SEC.TXI 0 N G T

SUMMARY

EXAMINATION AREA CATEGY EXXHE I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET t C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-572-S SR. 4) 257068 4"-SI-2401-35 C-F-1 C PT 3.3-006 X 4/15/05 - PT Complete. No PIPE TO ELBOW C5.21 UT 5.4-004 recordable indications. 45S5.OAS x 4/15/05 - UT Complete. No 45S5.OCIR x 60S5.OAS X recordable indications. 70S5.OAX X **UT-48 / PSL-61** 257072 4"-SI-2401-36 C-F-1 C PT 3.3-006 X - - - 4/15/05 - PT Complete. No ELBOW TO PIPE C5.21 UT 5.4-004 - - - - recordable indications. 45S5.0AX X - - - 4/15/05 - UT Complete. No 45S5.0CIR S - - - 60S5.0AX x - - - recordable indications. 70S5.0AX K - - - **UT-48 / PSL-61** (REF. DWG. NO. 5614-P-572-S SH. 2) 257276 3"-SI-2402-8 C-F-1 C PT 3.3-005 X - - - 4/15/05 - PT Complete. No PIPE TO ELBOW C5.21 UT 5.4-003 - - - - recordable indications. 45S5.OAK X - - 4/15/05 - UT Complete. No 45S5.OCIR K - - - 60S5.OAX x - - - recordable indications. 70S5.OAX x - - - **UT-47** 257280 3'-SI-2402-9 C-F-1 C PT 3.3-005 X - - - 4/15/05 - PT Complete. No ELBOW TO PIPE C5.21 UT 5.4-003 - - - - recordable indications. 45S5.OAC X - - - 4/15/05 - UT Complete. No 45S5.OCIR X - - - 60S5.OAS X - - - recordable indications. 70S5.OAS X - - - **UT-47**

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 52 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEIAR COMPONENTS HIGH HEAD SAFETY INJECTION OUTSIDE CONTAINMENT 4-097 ASME -STATUS N I G SEC. XI N EG T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-572-S SH. 2) 257292 C F-A C VT-3 4.3-023 X - - - 4/15/05 - VT-3 Complete. No DOUBLE ACTING F1.20 Recordable Indications. RESTRAINT 257304 4"-SI-2402-1 C-F-1 C PT 3.3-005 X - - - 4/15/05 - PT Complete. No REDUCER TO TEE C5.21 UT 5.4-005 - - - - recordable indications. 45S5.0AX X - - - 4/18/05 - UT Complete. No 45S5.OCIR X - - - 60S5.0AX x - - - recordable indications. 70S2.25AX X - - - **UT-48 (PSL-61)** 257328 4"-SI-2402-6 C-F-1 C PT 3.3-005 X - - - 4/15/05 - PT Complete. No TEE TO PIPE C5.21 UT 5.4-005 - - - - recordable indications. 45S5.OAX - - - 4/18/05 - UT Complete. Root 45S5.OCIR K - - - 60S5.OAX X - - - geometry recorded. **UT-48 70S2.25AX - - X - (PSL-61)** 257344 4"-SI-2402-9 C-F-1 C PT 3.3-005 X - - - 4/15/05 - PT Complete. No TEE TO PIPE C5.21 UT 5.4-005 - - - - recordable indications. 45S550AX X - - - 4/18/05 - UT Complete. No 45S5.OCIR K - - - 60S5.OAX X - - - recordable indications. 70S2.25AX X - - - **UT-48 (PSL-61)** _R _ ___ ___ __ D__ _ _ N_O_._ _ _ _ _ __-_- __ __ __ __ _ __ __ __ __ __ __ __ __ __ __ __ __ _ __ __ __ __ __ __ __ __ __ __ __ __ _ __ (REF. DWG. NO. 5610-P-246 SH.1) 257384 2"-SI-2402-4 C-F-1 C PT 3.3-007 X - - - 4/15/05 - PT Complete. No PIPE TO ELBOW C5.30 recordable indications _R _ _ __ _DWG. _ N_O_._ _ _ _ _ _ _ _ _ _ _ __-_-_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _____ (REF. DWG. NO. 5610-P-246)

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 53 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS HIGH HEAD SAFETY INJECTION OUTSIDE CONTAINMENT 4-097 ASME N I SEC. XI SEC Xl-SR RSEHG S E H

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMPARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCR** (REF. DWG. NO. 5610-P-246) 257388 2"-SI-2402-5 C-F-1 C PT 3.3-007 2 - - - 4/15/05 - PT Complete. No ELBOW TO PIPE C5.30 recordable indications (REF. DWG. NO. 5614-P-572-S SH. 2) 257436 2"-SI-2403-8 C-F-1 C PT 3.3-005 X - - - 4/15/05 - PT Complete. No PIPE TO ELBOW C5.30 recordable indications 257440 2"-SI-2403-9 C-F-1 C PT 3.3-005 X - - - 4/15/05 - PT Complete. No ELBOW TO PIPE C5.30 recordable indications (REF. DWG. NO. 5614-P-572-S SH. 1) 257516 4-SIH-53 F-A C VT-3 4.3-022 X - - - 4/16/05 - VT-3 Complete. No DOUBLE ACTING F1.20 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 54 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

4 INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS STEAM GENERATOR A BLOWDOWN INSIDE CONTAINMENT 4-105 ASME SATUS N I 0 SEC. XI O N G T R S EH REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G MR **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-790-S SH. 2) 268700 6"-BDA-2401-2 C-F-2 C MT 2.2-006 X 4/26/05 - MT Complete. No VALVE SGB-4-001 TO C5.51 UT 5.2-004 recordable indications. 45S2.2SAX X PIPE 4/26/05 - UT Complete. Root 45S2.2SCIR X 60S2.25AX X geometry recorded. **UT-22** 70S2.2SAX X 269100 6"-BDA-2401-6 C-F-2 C MT 2.2-006 X - - - 4/26/05 - MT Complete. No REDUCER TO VALVE C5.51 UT 5.2-004 - - - - recordable indications. SGB-4-002 45S2.2AX - - XX 4/26/05 - UT Complete. Root 45S2.25CIR X - -- 60S2.25AX - - X _ geometry recorded. **UT-22** 70S2.25AX X - - - 269400 6"-BDA-2401-9 C-F-2 C MT 2.2-006 X - - - 4/26/05 - MT Complete. No ELBOW TO PIPE C5.51 UT 5.2-004 - - - - recordable indications. 45S2 .25CR x - - - 4/26/05 - UT Complete. Root 60S2.25AX - - X - geometry recorded. **UT-22** 70S2.25AX - - X - 270000 6"-BDA-2401-l5 C-F-2 C MT 2.2-006 X - - - 4/26/05 - MT Complete. No PIPE TO ELBOW CS.51 UT 5.2-004 - - - - recordable indications. 45S2.25CAX - - - 4/26/05 - UT Complete. Root 45S2.25C1R K - - - 70S2.25AX - - X - and counterbore geometry 60S2.2SAX - - X - recorded. **UT-22**

DATE: 06/27/05 TURXEY POINT - UNIT 4 PAGE: 55 4 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS MAIN FEEDWATER SYSTEM LOOP A 4-111

SUMMARY

EXAMINATION AREA AH SEC. XI CATEGY r STATUS EXAM 0N RSE E I G 0 E H T REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALBIBRATION BLOCK** (REF. DWG. NO. 5614-P-557-S SN. 1) 281670 4-FWH-15 F-A C VT-3 4.3-037 X - - - 4/25/05 - VT-3 Complete. No SPRING HANGER F1.20 Recordable Indications. 282700 14"-FWA-2401-21 C-F-2 C MT 2.2-003 X - - - 4/20/05 - MT Complete. No ELBOW TO PIPE C5.51 UT 5.2-003 - - - - recordable indications 705S2.25AX1 - - - 4/21/05 - UT Complete. Backing Ring recorded

                                                                                          **UT-20**

282900 14"-FWA-2401-3A C-F-2 C MT 2.2-003 X - - - 4/20/05 - MT Complete. No ELBOW TO PIPE C5.51 UT 5.2-001 - - - - recordable indications. 45S2.25CR X- - - 4/21/05 - UT Complete. Root 45S2.25CIR X - - - 60S2.25AX - - - geometry seen 360 degree 70S2.25AX - - X - intermittent **UT-20** 284460 Augmented Exam AUG A UT 5.16-001 - - - - 04/21/05 - UT Complete. FROM NOZZLE RAMP TO 1 60S2.25AX - - X - Root and counterbore PIPE DIA. ON ELBOW 60S5.OAX - X- geometry recorded. **UT-20, 70S5.OAX - - X - UT-29**

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 56 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS MAIN FEEDWATER SYSTEM LOOP B 4-112 ASME STATUS N I 0 SEC. XI _ 0 N G T R S E R

SUMMARY

EXAMINATION AREA CATEGY EXAM REMARKS E I ME NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET l C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-558-S SH. 1) 286400 14"-FWB-2402-14 C-F-2 C MT 2.2-004 X - 4/21/05 - MT Complete. No PIPE TO ELBOW C5.51 UT 5.2-002 - recordable indications 45S2.25AX X 4/22/05 & 4/25/05 - UT 45S2.25CIR X 60S2.25AX X

                                                                                      - Complete. No Recordable 70S2.25AX                       X       - Indications.  **UT-20**

286980 Augmented Exam AUG A UT 5.16-002 - - - - 4/22/05 - UT Complete. Root FROM NOZZLE RAMP TO 1 60S2.25AX - - X - and backing ring geometry PIPE DIA. ON ELBOW 60S5.0AX - - X- recorded. **UT-20, UT-29** 70552.2AX - - X - 70S5.0AX - - X -

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 57 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS MAIN FEEDWATER SYSTEM LOOP C 4-113 ASE -STATUS N I 0 SEC. XI ON G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-789-S SH. 1) 288150 CONT. PENETRATION F-A A VT-3 4.3-029 X - - - 4/21/05 - VT-3 Complete. No ANCHOR F1.20 Recordable Indications. 289650 Augmented Exam AUG A UT 5.16-003 - - - - 4/19/05 - UT Complete. Root FROM NOZZLE RAMP TO 1 60s2.25Ax - - K - geometry recorded. **UT-20, DIA. ON ELBOW 6055.OAX - - X - UT-29** 7052.25AX - - X - 70S5.OAX - - K -

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 58 REVISION: 4 INSERVICE INSPECTION RESULTS SUMOARY INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS MAIN FEEDWATER BYPASS LOOP A 4-114 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-770-S SH. 3) 290100 7884-R-014-01 F-A C VT-3 4.3-001 - - - X 4/12/05 - VT-3 Complete. DOUBLE ACTING F1.20 Field verified clearances RESTRAINT differ from drawing. Reference restraint drawing 5614-H-770 Sh. 42B R.I. Actual field clearances are 0" on wall side instead of 1/16" and 5/16" on the opposite side instead of 1/16". Engineering Disposition - Accept As-is. Reference CR 2005-10658.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 59 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS MAIN FEEDWATER BYPASS LOOP C 4-116 A5ME ~TATUS N I 0

SUMMARY

EXAMINATION AREA SEC. XI CATEGY F EXAM N G T E I 0 E REMART S NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-770-S SH. 1) 291600 7884-R-014-03 F-A C VT-3 4.3-008 X - - - 4/12/05 - VT-3 Complete. No DOUBLE ACTING F1.20 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 60 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 2 CPBEAR COMPONENTS RESIDUAL HEAT EXCHANGER A 4-117 ASME STATUS N I 0 SEC. XI F0 N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET I C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-M-4010) 292400 4-RHE-Al C-A C UT 5.24-001 - - - - 4/8/05 - UT Complete. No HEAD TO SHELL C1.20 45S2.25AX - - - recordable indications. 45S2.25C1R X - - - Scan is limited. **UT-55** 60S2.25AX X - - - 70S2.25AX X - - - 60L2.OOAX X - - - 292500 4-RHE-A2 C-A C UT 5.24-001 - - - - 4/8/05 - UT Complete. SHELL TO FLANGE C1.10 45S2.25AX X - - - Baffle plate geometry 45S2.25CIR X- - - recorded. **UT-55** 70S2.25AX X - - - 60L2.00AX X - - - 292800 4-RHE-SPA-1 SUPPORT F-A C VT-3 4.3-005 X - - - 4/8/05 - VT-3 Complete. No HEAT EXCHANGER LOWER Fl.40 Recordable Indications. SUPPORT Existing condition - the hole sizes are different at the interface of the exchanger to structural support. This results in only a 3 point contact of the nut at the top holes. No washers were installed. 292950 4-RHE-SPA-2 SUPPORT F-A C VT-3 4.3-004 - - - - 4/8/05 - VT-3 Complete. No HEAT EXCHANGER LOWER F1.40 Recordable Indications. SUPPORT Existing condition - the hole sizes are different at the interface of the exchanger to structural support. This results in only a 3 point contact of the nut at the top holes. No washers were installed.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 61 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER INSIDE CONTAINMENT 4-120 ASME STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R *"CALIBRATION BLOCK"* (REF. DWG. NO. 5614-P-536-S SH. 1) 293800 4-ACH-150 F-A C VT-3 4.3-006 X - - - 4/11/05 - VT-3 Complete. No WELDED STANCHION F1.30 Recordable Indications.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 62 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM TO CCW PUMP C 4-122 4-12 ASE EC X SE .X rR

                                             -STATUS                          N   I S

R S E H 0 E HG REMARKS

SUMMARY

EXAM:NATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-518-S SH. 9) 295550 CCW PUMP 4P211C F-A C VT-3 4.3-036 X - - - 4/22/05 - VT-3 Complete. No PUMP SUPPORT Fl.40 Recordable Indications. CR 2005-12364 was written to identify coatings damage on the support.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 63 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER FROM NON-REGENERATIVE EX 4-125 ASNE .- TTSN I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E Pj2 LAROS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-528-S SH. 2) 296700 4-ACH-216 F-A C VT-3 4.3-020 X - - - 4/13/05 - VT-3 Complete. No SINGLE ACTING F1.30 recordable Indications. RESTRAINT 296750 4-ACH-216 IA D-A C VT-1 4.1-004 X - - - 4/13/05 - VT-i Complete. No INTEGRAL ATTACHMENT Dl.20 recordable indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 64 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER FROM R8R HEAT EXCHANGER A 4-126 AM STATUS 0 N G SEC. XI F RS E REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-518-S SR. 4) 297900 4-CCH-19 F-A C VT-3 4.3-031 X - - - 4/23/05 - VT-3 Complete. No SINGLE ACTING F1.30 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 65 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM OUTSIDE CONTAINMENT 4-127 ASME -STATUS N I 0 SEC. XI - N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-518-S SH. 6) 298300 4-ACH-64 F-A C VT-3 4.3-033 X - - - 4/23/05 - VT-3 Complete. No DOUBLE ACTING F1.30 Recordable Indications. RESTRAINT Clearances are acceptable per STD-C-Ol Rev.3 298350 4-ACH-64 IA D-A C VT-1 4.1-012 X - - - 4/23/05 - VT-1 Complete. No INTEGRAL ATTACHMENT Di.20 recordable indications

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 66 4 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER SYSTEM OUTSIDE CONTAINMENT 4-129 ASME TATUS N I 0 O N G T SEC. XI R S EH RERKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET t C G MR **CALIBRATION BELOCK** (REF. DWG. NO. 5614-P-526-S S8. 5) 299400 4-ACH-51 F-A C VT-3 4.3-035 X - - - 4/23/05 - VT-3 Complete. No SINGLE ACTING Fl.30 Recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 67 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER TO NORMAL CONT.COOLERS A&8 4-130 ASME -. TTSN I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY WM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-539-S SH. 3) 299800 4-CCH-52 F-A C VT-3 4.3-024 X - - - 4/15/05 - VT-3 Complete. No DOUBLE ACTING F1.30 Recordable Indications. RESTRAINT 299850 4-CCH-52 IA D-A C VT-1 4.1-006 X - - - 4/15/05 - VT-1 Complete. No INTEGRAL ATTACHMENT D1.20 recordable indications (REF. DWG. NO. 5614-P-539-S SH. 1) 300160 NORMAL CTMT COOLER F-A C VT-3 4.3-017 - - - X 4/14/05 - VT-3 Complete. COOLER SUPPORT F1.40 4.3-028 X - - - Loose nut/bolt assembly was observed. Spins in place. Engineering disposition: Tighten nut/bolt assembly and re-examine. 4/21/05 - VT-3 Complete. Re-examination after corrective action per CR 2005-10979

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 68 INSERVICE INSPECTION RESULTS

SUMMARY

REVISION: 4 INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER TO NORMAL CONT.COOLERS C&D 4-142 ASME -SSATUS N I 0 SEC. XI O N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I O E NUM8ER IDENTIFICATION ITEM NO 21ETHOD DATA SHEET S C G M R **CALIBPRTION BLOCK** (REF. DWG. NO. 5614-P-539-S SH. 2) 308100 4-CCH-67 F-A C VT-3 4.3-018 X - - - 4/13/05 - VT-3 Complete. No DOUBLE ACTING F1.30 recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 69 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS COMPONENT COOLING WATER FROM EMERGENCY CONT.COOL.A 4-148 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET U C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-532-S SH. 1) 311900 4-CCH-41 F-A C VT-3 4.3-019 X - - - 4/13/05 - VT-3 Complete. No DOUBLE ACTING F1.30 recordable Indications. RESTRAINT

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 70 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS AUXILIARY FEEDWATER SYSTEM PUMP DISCHARGE 4-161 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E M A R 4 NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET J C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-807-S SH. 4) 323250 80117-H-324-11 F-A C VT-3 4.3-009 X - - - 4/12/05 - VT-3 Complete. No DOUBLE ACTING F1.30 Recordable Indications. RESTRAINT 323275 80117-H-324-11 IA D-A C VT-1 4.1-002 X - - - 4/12/05 - VT-1 Complete. No INTEGRAL ATTACHMENT D1.20 recordable indications 323450 80117-H-324-13 F-A C VT-3 4.3-002 - - - X 4/12/05 - VT-3 Complete. SINGLE AND DOUBLE F1.30 4.3-002A - - - X Field verified clearances ACTING RESTRAINT differ from drawing. Reference restraint drawing 5614-H-807 Sh. 49B R.0. Actual field clearances are 0" on East, 7/8" on the top, 3/8" on the West, and 3/32" on the bottom. 3/4" rod is rubbing on L-beam causing measurable wear. 1/16" metal loss on rod and 1/32" metal loss on L-beam. Engineering Disposition - Accept As-is. Reference CR 2005-10665. 4/28/05 - Additional measurements taken for clearances utilizing filler gauges for clearance measurements instead of 1/16" scale.

DATE: 06/27/05 TURKEY POINT - UNIT 4 PAGE: 71 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 4, PERIOD 1, OUtTAGE 1 (05) CLASS 3 CPBEAR COMPONENTS INTAKE & CHLOR.WATER FROM INTAKE COOLING WTR.PUMPS 4-165 ASME ,TTSN I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** (REF. DWG. NO. 5614-P-507-S SH. 1) 328500 2 F-A C VT-3 4.3-010 X - - - 4/13/05 - VT-3 Complete. No SINGLE ACTING F1.30 Recordable Indications. RESTRAINT

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE Summary of Inservice Inspection IWE Examinations Attachment 3

DATE: 08/15/05 FPL NUCLEAR PLANTS [IWE] - UNIT 4 PAGE: 1 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS M CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-001 ASME STATUS N I 0 SEC. XI 0 N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK" 14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. 410000 CONTAINMENT LINER E-A B VT-3 4.7-016 X - - - 4/25/05 - Pre- repair LINER PLATE-GENERAL E1.1l VT-3 4.7-027 X - - - inspection per CR 03-3523, VISUAL VT-3 4.7-028 X WO 34003355-01 5/6/05 - Intermediate inspection 5/13/05-Partial inspection of coating 5/23/05-Final inspection 410150 PENETRATION #15 E-A B VT-3 4.7-016 - - - X 4/25/05 - Pre- repair CHARGING TO REGEN HX E1.ll VT-3 4.7-027 X - - - inspection per CR 03-3523, TYPEI DETAIL3 VT-3 4.7-028 - - - WO 34003355-01 5/6/05 - Intermediate inspection 5/13/05-Final inspection 410930 MOISTURE BARRIER E-D B VT-3 4.7-001 - - - X 4/11/05- Pre-repair LINER PLATE TO FLOOR E5.30 VT-3 4.7-032 X - - - inspection per (MOISTURE BARRIER) VT-3 4.7-033 - - - X CR2004-12917,WO034019930-01 VT-3 4.7-036 - - - X VT-3 4.7-037 x - - - 5/17/05- Inspection after VT-3 4.7-038 x - - - sealant removal (partial) VT-3 4.7-041 X - - - 5/18/05- Inspection after cleaning 5/18/05- Inspection after sealant removal (partial) 5/19/05- Inspection after cleaning (partial) 5/20/05- Final Inspection 5/23/05- Final Moisture Barrier Walkdown (100%)

DATE: 08/15/05 FPL NUCLEAR PLANTS EIWE] - UNIT 4 PAGE: 2 REVISION: INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS M CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-u°Z ASME -STATUS N I 0 SEC. XI o N G T R S EH

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATrrASHEET # C G MR **CALIBRATION BLOCK"* 74 TO 134 DEGREES AT 14' TO 39 (REF. DWG. NO. ) 411020 MOISTURE BARRIER E-D B VT-3 4.7-002 X 4/11/05- Pre-rpair LINER PLATE TO FLOOR E5.30 VT-3 4.7-009 X inspection per CR VT-3 4.7-012 X (MOISTURE BARRIER) 2004-12917, WO#34019930-01 VT-3 4.7-014 x VT-3 4.7-034 X 4/14/05- Intermediate VT-3 4.7-039 x inspection after sealant VT-3 4.7-040 X removal (partial) VT-3 4.7-041 x 4/19/05- Intermediate inspection after cleaning (partial) 4/22/05- Final inspection (partial) 5/18/05- Intermediate inspection after sealant removal (partial) 5/18/05- Intermediate inspection after cleaning (partial) 5/20/05- Final inspection (partial) 5/23/05- Final Moisture Barrier Walkdown (100%)

DATE: 08/15/05 FPL NUCLEAR PLANTS [IWE] - UNIT 4 PAGE: 3 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS M CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-003 ASME -STATUS N I 0 SEC. XI 0 N G T R S EH REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I OE NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** 134 TO 194 DEGREES AT 14' TO 39'6" (REF. DWG. NO. ) 411110 MOISTURE BARRIER E-D B VT-3 4.7-003 X 4/11/05- Pre-repair LINER PLATE TO FLOOR E5.30 VT-3 4.7-010 X inspection per VT-3 4.7-013 X (MOISTURE BARRIER) CR-2004-12917, VT-3 4. 7-015 VT-3 4.7-041 x _ WO#34019930-01 4/14/05- Intermediate inspection after sealant removal 4/21/05- Intermediate inspection after cleaning 4/22/05- Final inspection 5/23/05- Final Moisture Barrier Walkdown (100%)

DATE: 08/15/05 FPL NUCLEAR PLANTS [SWE] - UNIT 4 PAGE: 4 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS M CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-004 ASME -STATUS N I 0 SEC. XI 0 N G T SUMWARY EXAMINATION AREA CATEGY E I E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** 194 TO 254 DEGREES AT 14' TO 39'6" (REF. DWG. NO. ) 411300 MOISTURE BARRIER E-D B VT-3 4.7-004 X 4/11/05- Pre-repair LINER PLATE TO FLOOR E5.30 VT-3 4.7-011 X inspection per VT-3 4.7-020 x (MOISTURE BARRIER) CR-2004-12917, VT-3 4.7-023 x VT-3 4.7-041 X _ WOJ34019930-01 4/16/05- Intermediate inspection after sealant removal 4/26/05- Intermediate inspection after cleaning 5/2/05- Final inspection 5/23/05- Final Moisture Barrier Walkdown (100%)

DATE: 08/15/05 FPL NUCLEAR PLANTS [IWE] - UNIT 4 PAGE: 5 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS X CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-005 ASME -STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** 254 TO 314 DEGREES AT 14' TO 39'6" (REF. DWG. NO. ) 411440 MOISTURE BARRIER E-D B VT-3 4.7-005 X 4/11/05- Pre-repair LINER PLATE TO FLOOR E5.30 VT-3 4.7-021 X inspection per VT-3 4.7-022 X (MOISTURE BARRIER) CR-2004-12917, VT-3 4.7-024 X VT-3 4.7-041 K WO#34019930-01 4/26/05- Intermediate inspection after sealant removal 4/30/05- Intermediate inspection after cleaning 5/2/05- Final inspection 5/23/05- Final Moisture Barrier Walkdown (100%)

DATE: 08/15/05 FPL NUCLEAR PLANTS LIWE] - UNIT 4 PAGE: 6 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS H CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-006 ASME -STATUS 0 N G SEC. XI 0 SEG

SUMMARY

EXAMINATION AREA CATEGY ESAM E I 0E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET t C G M R **CALIBRATION BLOCK** 314 TO 14 DEGREES AT 14' TO 39'6" (REF. DWG. NO. ) 411580 MOISTURE BARRIER E-D B VT-3 4.7-006 X 4/12/05- Pre-repair LINER PLATE TO FLOOR E5.30 VT-3 4.7-025 K inspection per (MOISTURE BARRIER) VT-3 4.7-029 x CR-2004-12917, VT-3 4.7-030 x VT-3 4.7-031 K WOt34019930-01 VT-3 4.7-041 K 5/2/05- Intermediate inspection after sealant removal 5/13/05- Intermediate inspection after sealant removal 5/13/05- Intermediate inspection after cleaning 5/16/05-Final inspection 5/23/05- Final Moisture Barrier Walkdown (100%)

DATE: 08/15/05 FPL NUCLEAR PLANTS [MlE] - UNIT 4 PAGE: 7 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS M CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-015 ASME -TUSN I 0 SEC. ATxS 0 N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** 134 TO 194 DEGREES AT 59'6" TO 125'10" (REF. DWG. NO. ) 412020 LINER PLATE E-A B GEN. 4.7-008 x 4/15/05- Pre-cut-out LINER PLATE (GENERAL E1.11 GEN. 4.7-007 X inspection. VISUAL) GEN. 4.7-026 x 4/17/05- Post cut-out GEN. 4.7-042 X GEN. 4.7-043 X inspection. Initiated GEN. 4.7-044 x CR-2005-11136 GEM. 4.7-047 x 5/3/05- Pre-cut-out inspection (expanded area). 4/23/05- Pre-coating removal inspection (hanger area). CR-2005-10670 SCR-03-3523 5/23/05- Post-coating removal inspection (hanger area). 5/23/05- Final inspection (hanger area). 5/23/05- Final inspection of SGT liner plate cut-out.

DATE: 08/15/05 FPL NUCLEAR PLANTS [IWE] - UNIT 4 PAGE: 8 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS M CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-020 ASME STATUS N I 0 SEC. XI O N G T

SUMMARY

EXAMINATION AREA CATEGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO L METHOD DATA SHEET # C G M R *"*CALIBRATION BLOCK** SOUTH RECIRC SUMP (REF. DWG. NO. 5610-C-150) 412250 LINER PLATE E-A C GEN 4.7-017 - - - X 4/23/05- General Visual SOUTH RECIRC SUMP E4.11 VT-3 4.7-046 X - - - complete. CR-2005-10670 & VT-3 4.7-048 X- - - CR-03-3523 5/23/05- VT-3 Complete after repair per PCM-05-069. Repaired areas now inaccessible. 5/25/05- Final Inspection after repair per PCM-05-069. NORTH RECIRC SUMP (REF. DWG. NO. 5610-C-150) 412260 LINER PLATE E-A C GEN 4.7-018 - - - X 4/25/05- General Visual NORTH RECIRC SUMP El.l1 GEN 4.7-019 X - - - complete. CR-2005-10670 a VT-3 4.7-046 - - - CR-03-3523 VT-3 4.7-048 X - - - 4/29/05- Intermediate inspection prior to coating. 5/23/05- VT-3 Complete after repair per PCM-05-069. Repaired areas now inaccessible. 5/25/05- Final Inspection after repair per PCM-05-069. RX SUMP LINER PLATE (REF. DWG. NO. 5610-C-150) 412290 LINER PLATE E-A C GEN 4.7-049 - - - X 5/25/05- General visual RX SUMP AREA E1.l1 complete. Coating Failure in RX Drain Sump. ______________________SO___TH______C___RC___BUMP_________F.___D_______NO.______________________ SOUTH RECIRC SUMP (REF. DWG. NO. 5610-C-150)

DATE: 08/15/05 FPL NUCLEAR PLANTS JIWE] - UNIT 4 PAGE: 9 REVISION: 4 INSERVICE INSPECTION RESULTS

SUMMARY

INTERVAL 1, PERIOD 2, OUTAGE 3 (05) CLASS M CPBEAR COMPONENTS METALLIC CONTAINMENT LINER 4-020 ASME STATUS N I 0 SEC. XI _ O N G T R S E H REMARKS

SUMMARY

EXAMINATION AREA CATEGY EXAM E I O E NUMBER IDENTIFICATION ITEM NO METHOD DATA SHEET # C G M R **CALIBRATION BLOCK** SOUTH RECIRC SUMP (REF. DWG. NO. 5610-C-150) 412300 LINER PLATE E-C A VT-1 4.7-035 - - - X 5/19/05- Visual complete. SOUTH RECIRC SUMP E4. 11 CR-2005-10670 S CR-03-3523 (AUGMENTED VT-1) Note: Repair makes degraded areas inaccessible to future inspections. 412310 LINER PLATE E-C A VOL. 5.18-002 - - - X 5/19/05- UT Thickness SOUTH RECIRC SUMP E4.12 complete. CR-2005-10670 & (AUGMENTED VOL) CR-03-3523 Note: Repair makes degraded areas inaccessible to future inspections. NORTH RECIRC SUMP (REF. DWG. NO. 5610-C-150) 412320 LINER PLATE E-C A VT-1 4.7-035 - - - X 5/19/05- Visual complete. NORTH RECIRC SUMP E4.11 CR-2005-10670 A CR-03-3523 (AUGMENTED VT-1) Note: Repair makes degraded areas inaccessible to future inspections. 412330 LINER PLATE E-C A VOL. 5.18-001 - - - X 5/19/05- UT Thickness NORTH RECIRC SUMP E4.12 complete. CR-2005-10670 a (AUGMENTED VOL) CR-03-3523 Note: Repair makes degraded areas inaccessible to future inspections.

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE Summary of Visual Examinations and Functional Testing of Snubbers Attachment 4

1. MECHANICAL SHOCK ARRESTOR FINAL REPORT TURKEY POINT UNIT 4 2005 CYLCE 22 REFUELING OUTAGE Commercial Service Date: December 14, 1972 Prepared by: Inservice Inspection Group Florida Power & Light Turkey Point Nuclear 9760 S.W. 344 St. Florida City, FL 33035 Originated by: Melba Campbel Date 6/121015 Reviewed by: d- Ricky 9PTilian Da e Approved by: Chuck Tudor D~te Word:ptnsfo2/vol. Ilcomzno n/frp198

Mechanical shock arrestors (snubbers) were visually inspectedlhandstroked and functionally tested under purchase order #00081442 by Basic-PSA personnel in accordance with the following plant procedures: O-OSP-105.1 O-OSP-105.2 A technical specification visual inspection, ASME Section XI VT-3 and a hand stroking was performed at the following tag locations: 4-1000 4-1001 4-1002 4-1003 4-1004 4-1005 4-1006 4-1008 4-1009 4-1012 4-1013 4-1015 4-1016 4-1017 4-1019 4-1020 4-1021 4-1065 4-1071 4-1086 4-1087 4-1088 4-1089 4-1090 4-1091 4-1092 4-1094 4-1095 4-1096 4-1097 4-1098 4-1099 A technical specification visual inspection, ASME Section XI VT-3, NO HAND STROKE, and a functional test was performed at the following tag locations: 4-1014 4-1018 4-1032 4-1077 4-1082 4-1084 4-1100 4-1007 4-1010 4-1048 4-1093 4-1011 4-1022 4-1039 Italics indicates SR Sample snubbers Bold indicates QR Sample snubbers Underline indicates previous rebuilds A technical specification visual inspection, ASME Section XI VT-3 and a hand stroking was performed at the following tag locations 4-1052,4-1054,4-1055,4-1056,4-1057. Upon completion of the technical specification visual inspection and an ASME Section XI VT-3 snubbers 4-1044,4-1045,4-1051 and 4-1053 were changed out with previously rebuilt and functionally tested snubbers. The removed snubbers were rebuilt and functionally tested and will be utilized as spares for future outages. 4-1044 4-1045 4-1051 4-1052 4-1053 4-1054 4-1055 4-1056 4-1057 Word~ptnsfo2/vol.1/commonLfrtpl98

TURKEY POINT I),CLEAR PLANT OUTAGE

SUMMARY

REPORT UNIT 4 C22 OUTAGE REPORT WO # TAG# SERIAL# REPLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S INSPECTION

SUMMARY

FUNCTIONAL TEST

SUMMARY

MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _.._.. _.._.._.._.._.._.._.._.._.._.._...I ._._. .._ ._.._.._..._. ._. ._. ... _...._._,_....

                                                                                                       ..   $-f..      .... _....  .. _._.._.   ._.._...._. ._. . _. ... _.._.._.._.._.._.._

4-1000 182 N/A 4/1812005 PASS N/A NIA 21.750 NMA YES PASS Visualinspection-SAT,VLDimensfon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1001 18010 13.125 4/18/2005 PASS N/A N/A 13.125 PASS YES PASS Visual inspection-SAT."L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS NA DATE REINSTALLED:

TAG # SERIAL #. ..'LACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S " INSPECTION

SUMMARY

FUNCTIONAL TEST SUM.. ,Y MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1002 18016 NMA 411812005 PASS N/A N/A 13.062 PASS YES PASS Vlsual Inspection-SAT,'L" Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4.1003 18008 N/A 4/1812005 PASS N/A N/A 13.062 PASS YES PASS Visualinspection-SAT,L"VDimenslon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG# SERIAL## PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S ' ' INSPECTION

SUMMARY

FUNCTIONAL TEST SUM,.-..IY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1004 3168 N/A 4/11/2005 PASS N/A N/A 26.875 PASS YES PASS Visuallnspection-SAT,"LDimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4.1005 1206 N/A 4/11/2005 PASS N/A N/A 27.0 PASS YES PASS VisualInspection-SAT,."LDimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG# SERIAL##tuPLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND. S . - INSPECTION

SUMMARY

FUNCTIONAL TEST SUM..J..Y MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _.... .. a .. _.._..._.._.._.._.. _.. ......... .. _.._.._.. ... _.. .... _......_.._.._.._... . _.._.._._.. _.. _.. _.. _.. _.._.._. 4.1006 8087 N/A 4/1212005 PASS N/A N/A 26.5 PASS YES PASS Visual2lnspection-SAT,VDimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1007 6521 N/A 4/11/2005 PASS 04/11/05 PASS 26.75 PASS NO N/A Visual Inspection noted a worn spherical FUNCTIONAL TEST PERFORMED? YES bearing, 'L! dimension was SAT. Snubber was removed and transported STATUS PASS (N/A IF NOT PERFORMED) to the test trailer for functional testing. The as- found functional test was SAT. TENSION COMPRESSION CRITERIA The spherical bearing was replaced (CR 2005-10417), snubberwas re-greased TEST 1 125.8 192.4 2500.0 and as left functional test-SAT. TEST 2 158.4 326.1 2500.0 Spherical bearings and load pin lubricated with neolube UTC # 449261. TEST 3 0.003 0.002 .02g's As-Left VIsual Inspection-SAT. TEST 4 267.9 384.3 2500.0 TEST SAMPLE? YES SAMPLE CLASS OR DATE REINSTALLED: 04/14/05

TAG # SERIAL # . -PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S ' INSPECTION

SUMMARY

FUNCTIONAL TEST SUM. .AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T ...... _.. _.. _.... _.. _.. _.. _.. _.. _.._.._.._.. _.. _.. _.. _.. _.. _.. _.. _.. _.... ..... _.. _.. _.. _.. _.............. .. _.._.._.._... _ .. _.._... . _.... _.... _.._..._6. *...._,.,.._.. _.. _.. _.._--. 4-1008 6485 N/A 4/11120D5 PASS N/A N/A 27.625 PASS YES PASS Visuallnspection-SAT,L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1009 1203 N/A 4/11/2005 PASS N/A N/A 27.25 PASS YES PASS Visual lnspectlon-SATL Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL # .zPLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S*. INSPECTION

SUMMARY

FUNCTIONAL TEST SUNM. .AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T ...... _.._.._.._.._.._.._.._.._............._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._..-.._.._......_I.. ..... _.................. ...... _......._.._.._........................... 4.1010 1204 N/A 4/1212005 PASS 041205 PASS 27.187 PASS NO PASS Visual Inspection-SAT, L dimension FUNCTIONALTEST PERFORMED? YES was SAT. Snubber was removed and transported to the test trailer for STATUS PASS (NIA IF NOT PERFORMED) functional testing. The functional test was SAT. Snubber was tom down and TENSION COMPRESSION CRITERIA re-greased. As-left visual-SATand as-left functional test- SAT. Transition end TEST 1 274.7 987.9 2500.0 piece torqued to 150 In lbs. (Torque TEST 2 483.6 987.9 2500.0 wrench M321, cal due 7112/05). Spherical bearings and load pin TEST 3 0.001 0.001 .02gs lubricated with neolube UTC # 449261. Snubber was re-installed. TEST 4 435.9 448.1 2500.0 TEST SAMPLE? YES SAMPLE CLASS OR DATE REINSTALLED: 04114105 4.1011 10573 N/A 4112/2005 PASS 04/12105 PASS 27.25 PASS NO NIA Visual lnspection-SAT,L" Dimension FUNCTIONAL TEST PERFORMED? YES Acceptable, and Functional-SAT. Spherical bearings and load pin STATUS PASS (NIA IF NOT PERFORMED) lubricated with neolube UTC 449261. As-left visual Inspectlon-SAT. This snubber TENSION COMPRE SSION CRITERIA was a previous failure. TFCT A 977 7 On S I I I; I - ,., &Iv.J 2500.0 TEST 2 304.4 353.0 2500.0 TEST 3 0.002 0.002 .02g's TEST 4 639.1 254.8 2500.0 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 04/14/05

TAG # SERIAL. # -. LACE- VISUAL S FUNCTIONAL S L DIMEN S HAND. S ' -. INSPECTION

SUMMARY

FUNCTIONAL TEST SUM, BY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T - I. .. .. .. . .. . . . . . .. . .. . ._.._.. I . .. _. _... 4-1012 184 NIA 4118/2005 PASS N/A N/A 20.187 PASS YES PASS Visualinspection-SAT,VDimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS NIA (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1013 17418 N/A 4/1812005 PASS NIA N/A 17.375 PASS YES PASS Visuallnspection-SAT,-L"Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG* SERIAL##...,LACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S s -- INSPECTION

SUMMARY

FUNCTIONAL TEST SUMS. BY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _.._.. .. . . . .. . .. *I.............._.._....... . _.._.._..._..... ... ...... .. _.. _.._... _... . .._ .._ .._....._.... ... .... _...... . . _.._. 4.1014 17177 N/A 4118/2005 PASS 04/18105 PASS 21.125 PASS NO N/A Visual lnspection-SATV dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Snubber torqued to transition tube at 35 STATUS PASS (N/A IF NOT PERFORMED) ft. ibs.(Torque wrench M470, cal due 7/22/05). Spherical bearings and load TENSION COMPRESSION CRITERIA pin lubricated with neolube UTC 449261. As left visual inspection -SAT. Replaced TEST 1 59.5 57.2 750.0 load pin. TFST 2 A65.5 677 750. TEST 3 0.002 0.004 0.2g's TEST 4 59.4 43.4 750.0 TEST SAMPLE? YES SAMPLE CLASS SR DATE REINSTALLED: 04/18/05 441015 17872 NWA 4118/2005 PASS N/A N/A 19.875 PASS YES PASS VisualInspection-SAT,TL 5 Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/hA (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG# SERIAL# P rPLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S INSPECTION

SUMMARY

FUNCTIONAL TEST SUM .... IY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1016 122 NIA 4118/2005 PASS N/A NMA 20.00 PASS YES PASS Visuallnspection-SAT,"L"Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1017 118 NMA 4/18/2005 PASS N/A N/A 20.125 PASS YES PASS Visualinspection-SAT, Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NWA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTAL

TAG # SERIAL #. ..JLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S - - INSPECTION

SUMMARY

FUNCTIONAL TEST SUMU ,v MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _.,_,,_ ,,_,_,.. _.. _.. _.._. ._.. _.._.._.... .. .. .. _.._,.. _.. _.. _.. _.._. . _.. _.. _.. _,,_,,_,,_,,_,,_,,_,,_,,_.._.._...._......._.._ . ._.,_,,_. ,I_.., _... ...... ............ ...... _......_. 4.1018 17420 N/A 4/18/2005 PASS 04/18/05 PASS 17.875 PASS NO NMA Visual lnspection-SAT,'L dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Snubber torqued to transition tube at STATUS PASS (N/A IF NOT PERFORMED) 120 In. Ibs.(Torque wrench B5177, cal due 614/05). Spherical bearings and TENSION COMPRESSION CRITERIA load pin lubricated with neolube UTC 449261. As left visual Inspection -SAT. TEST 1 16.9 17.0 300.0 TEST 2 23.9 17.1 300.0 TEST 3 0.011 0.007 .02g's TEST 4 16.8 23.9 300.0 TEST SAMPLE? YES SAMPLE CLASS SR DATE REINSTALLED: 04/18/05 4-1019 17426 N/A 4/18/2005 PASS N/A N/A 16.875 PASS YES PASS Visuallnspection-SAT,'LDimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALI

TAG # SERIAL # ... PLACE- VISUAL S FUNCTIONAL S LDIMEN S HAND- S - INSPECTION

SUMMARY

FUNCTIONAL TEST SUMh....RY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4.1020 27101 NIA 4/16/2005 PASS N/A N/A 17.125 PASS YES PASS Visuallnspection-SAT,'LDimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Handstoke-SAT. Spherical bearings and load pin lubricated with STATUS NMA (N/A IF NOT PERFORMED) neolube UTC 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS DATE REINSTALLED: 4-1021 19723 N/A 4/16/2005 PASS N/A N/A 17.125 PASS YES PASS Visual lnspectlon-SATV Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Handstoke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC 449261. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG# SERIAL# ... PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND. S " INSPECTION

SUMMARY

FUNCTIONAL TEST SUMi...AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1022 21381 N/A 4/1512D05 PASS 041505 PASS 16.312 PASS NO N/A Visual lnspection-SAT,.L dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Snubber torqued to transition tube at STATUS PASS (N/A IF NOT PERFORMED) 120 In.lbs.(Torque wrench E504, cal due 6/4/05). Spherical bearings and TENSION COMPRESSION CRITERIA load pin lubricated with neolube UTC 449261. As left visual Inspection -SAT. TEST 1 15.7 21.2 300.0 TEST 2 22.2 29.0 300.0 TEST 3 0.005 0.002 .02g's TEST 4 27.6 31.4 300.0 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 04/15/05 4-1032 3707 N/A 4/19/2005 PASS 04/19/05 PASS 25.75 PASS NO N/A Visual Inspection-SATL Dimension FUNCTIONAL TEST PERFORMED? YES Acceptable, and Functional-SAT. Spherical bearings and load pin STATUS PASS (N/A IF NOT PERFORMED) lubricated with neolube UTC 449261. As-left visual Inspection-SAT. TENSION COMPRESSION CRITERIA TEST 1 174.4 226.6 2500.0 TEST 2 260.1 662.6 2500.0 TEST 3 0.003 0.004 .02g's TEST 4 227.3 262.4 2500.0 TEST SAMPLE? YES SAMPLE CLASS SR DATE REINSTALLED: 04/19/05

TAG#I SERIAL # .. .LACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S - INSPECTION

SUMMARY

FUNCTIONAL TEST SUMWAY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T

   .................           ........ .. .... ... m... -.....  *.....   ...-............ m............... C  -. m.................... S n*......I.. .... ... .................. I....      .... ....   ... m..... ...............        ...... m..-... m.......

4.1 039 42872 NWA 411912005 PASS 4117105 PASS 25.562 PASS NO N/A Visual inspection performed- FUNCTIONAL TEST PERFORMED? NO SAT.Functional test was performed on new snubber-SAT. Torqued transition STATUS PASS (N/A IF NOT PERFORMED) tube to 500 FT/LBS. Torque Wrench M779 Due 7/311205. Spherical TENSION COMPRESSION CRITERIA bearings and load pin lubricated with neolube UTC # 449261. TEST 1 103.7 107.3 1000.0 TEST 2 146.3 213.4 1000.0 TEST 3 0.005 0.005 .02g's TEST 4 141.6 294.3 1000.0 TEST SAMPLE? NO SAMPLE CLASS NIA DATE REINSTALLED: 4/19105 4-1 039 11923 42872 41161205 PASS 04/16/05 PASS 25.562 PASS NO N/A Visual Inspection-SAT,"L dimension FUNCTIONAL TEST PERFORMED? NO acceptable and functional test -SAT. (Worn parts noted, snubber was STATUS PASS (N/A IF NOT PERFORMED) replaced with new Functional Tested snubber).This Snubber was replaced TENSION COMPRESSION CRITERIA U4C21 outage. TESTI1 110.6 61.0 2500.0 TEST 2 265.6 560.8 2500.0 TEST 3 0.001 0.002 .02g's TEST4 249.1 516.9 2500.0 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 04119/05

TAG# SERIAL# -.- PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S INSPECTION

SUMMARY

FUNCTIONAL TEST SUMi .dY Y MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _.._..._ ... ._ .. _, .I...._.._ .... _...._...._..... ... .... .. 4.1044 17902 12377 4/13/2005 PASS 04/13/05 PASS 21.50 PASS NO N/A Visual Inspectlon-SATLC Dimension FUNCTIONAL TEST PERFORMED? YES Acceptable, and Functional-SAT. Snubber was scheduled to be replaced STATUS PASS (NIA IF NOT PERFORMED) as part of the rotation cycle for PRZR snubbers. 4-1044 SIN 17902 was TENSION COMPRESSION CRITERIA replaced with tested SIN 12377. As-Lsft Visual Inspection-SAT. Spherical TEST 1 58.5 44.4 750.0 bearings and load pin lubricated with TEST 2 77.4 66.1 750.0 neolube UTC 449261. The removed snubber SIN 17902 was functionally TEST 3 0.006 0.005 .02g's tested -SAT. The removed snubber will be used as a spare. TEST 4 78.6 51.6 750.0 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 04/13/05 4-1045 17906 16245 4/13/2005 PASS 04/13105 PASS 21.50 PASS NO N/A Visual Inspection-SAT,L" Dimension FUNCTIONAL TEST PERFORMED? YES Acceptable, and Functional-SAT. Snubber was scheduled to be replaced STATUS PASS (NIA IF NOT PERFORMED) as part of the rotation cycle for PRZR snubbers. 4-1045 SIN 17906 was TENSION COMPRESSION CRITERIA replaced with tested SIN 16245. As-Left Visual Inspection-SAT. Spherical TEST 1 39.7 92.6 750.0 bearings and load pin lubricated with TEST 2 53.3 93.2 750.0 neolube UTC 449261I.The removed snubber SIN 17906 was functionally TEST 3 0.008 0.009 .02g's tested -SAT.The removed snubber will be used as a spare. TEST 4 124.9 42.9 750.0 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 04/13105

TAG # SERIAL#. PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND. S INSPECTION

SUMMARY

FUNCTIONAL TEST SUM, ,sY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4.1048 4251 N/A 4/17/2005 PASS 04/17/05 PASS 20.750 PASS NO NMA Visual Inspection-SAT,'L dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Snubber torqued to transition tube at 35 STATUS PASS (N/A IF NOT PERFORMED) R'..Ibs.(Torque wrench 1857, cal due 5/15/05). Spherical bearTings and load TENSION COMPRESSION CRITERIA pin lubricated with neolube UTC 449261. As left visual Inspection -SAT. TEST 1 30.2 40.0 750.0 TEST 2 30.2 81.2 750.0 TEST 3 0.008 0.006 .02g's TEST 4 47.2 45.5 750.0 TEST SAMPLE? YES SAMPLE CLASS OR DATE REINSTALLED: 04/18/05 4.1051 11446 10174 4/13/2005 PASS 04/13/05 PASS 21.750 PASS NO N/A Visual Inspectlon-SAT,'L Dimension FUNCTIONAL TEST PERFORMED? YES Acceptable, and Functional-SAT. Snubber was scheduled to be replaced STATUS PASS (N/A IF NOT PERFORMED) as part of the rotation for PRZR snubbers. 4-1051 S/N 11446 replaced TENSION COMPRESSION CRITERIA with tested S/N 10174, tail piece was torqued to 35 ft. lbs (torque wrench TEST 1 12.4 42.1 300.0 M865, cal due 7123105) As-Left Visual TEST 2 43.3 107.9 300.0 Inspection-SAT. Spherical bearings and load pin lubricated with neolube UTC TEST 3 0.008 0.008 .02g's 449261.The removed snubber S/N 11446 was functionally tested-SAT. The TEST 4 37.0 106.0 300.0 removed snubber will be used as a spare. TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 04/13/05

TAG# SERIAL# ,o.PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S INSPECTION

SUMMARY

FUNCTIONAL TEST SUihi^Y MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1052 17904 N/A 4/13/2005 PASS N/A N/A 22.50 PASS NO N/A Visual lnspectlon-SAT.1T Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST4 TEST SAMPLE? NO SAMPLE CLASSN/A DATE REINSTALLED: 4.1053 16245 10172 4/13/2005 PASS 041305 PASS 21.75 PASS NO Visual Inspection-SAT,"L" Dimension FUNCTIONAL TEST PERFORMED? YES Acceptable, and Functional-SAT. Snubber was scheduled to be replaced STATUS PASS (N/A IF NOT PERFORMED) as part of the rotation cycle for PRZR snubbers. 4-1053 S/N 16245 was TENSION COMPRESSION CRITERIA replaced with tested S/N 10172. Final Visual Inspection-SAT. Spherical TEST 1 89.9 83.2 300.0 bearings and load pin lubricated with TEST 2 102.5 98.8 300.0 neolube UTC 449261.The removed snubber S/N 16245 was functionally TEST 3 0.007 0.007 .02gs tested-SAT. The removed snubber will be used as a spare. TEST 4 95.0 94.8 300.0 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 04/13/05

TAG # SERIAL # .. .LACE- ViSUAL S FUNCTIONAL S L DIMEN S HAND- S - INSPECTION

SUMMARY

FUNCTIONAL TEST SUM. 4:Y MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1054 15718 N/A 4113/2005 PASS N/A N/A 21.187 PASS YES PASS Visual lnspection-SATV Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Handstrmke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC #449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1055 16241 N/A 4/13/2005 PASS N/A N/A 20.687 PASS YES PASS Visualinspection-SAT,'V 5 Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS NMA (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL # . .PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S I INSPECTION

SUMMARY

FUNCTIONAL TEST SUM.. AY MENTSIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1056 12392 N/A 4/13/2005 PASS NMA N/A 21.0 PASS YES PASS Visuallnspectlon-SATL DimensIon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4.1057 27089 WIA 4/1312005 PASS N/A N/A 18.375 PASS YES PASS Visuallnspectlon-SAT,"L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N!A (NIA IF NOT PERFORMED) neolube UTC # 449251. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL #W... LACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S - INSPECTION

SUMMARY

FUNCTIONAL TEST SUM.I,tY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1065 20873 N/A 4/1712005 PASS N/A NIA 15.687 PASS YES PASS Visualinspection-SAT,"L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1071 17899 N/A 4/1712D05 PASS N/A N/A 20.50 PASS YES PASS Visual lnspectlon-SAT,"L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS NIA (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL #. mPLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S '-'. INSPECTION

SUMMARY

FUNCTIONAL TEST SUMhi.Y MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _*...._. .. _.._.. .. .. _.. _,.._. . _.. _.. _.. _.._.. _.._.._,,_._... _.. _.. _.. ._,,_,,_.._.._,,_,,-_ .._,_.._.._.*.._..._..__...._*. **. **. -. S.- - S. i...in. S. **.*. ** 5. .. _.. _ 4-1077 18014 N/A 411712005 PASS 04117105 PASS 13.50 PASS NO NIA Visual lnspectlon-SAT,"L! dimension FUNCTIONAL TEST PERFORMED7 YES acceptable and functional test -SAT. Spherical bearings and load pin STATUS PASS (NIA IF NOT PERFORMED) lubricated with neolube UTC 449261. As left visual Inspection -SAT. TENSION COMPRESSION CRITERIA TEST I 12.8 6.6 75.0 TEST 2 17.5 11.1 75.0 TEST 3 O.009 0.010 .02g's TEST 4 17.3 11.4 75.0 TEST SAMPLE? YES SAMPLE CLASS SR DATE REINSTALLED: 04117/05 4-1082 19296 NIA 4/19/2005 PASS 04/19/05 PASS 17.625 PASS NO N/A Visual Inspection-SAT,L" dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Spherical bearings and load pin STATUS PASS (NIA IF NOT PERFORMED) lubricated with neolube UTC 449261. As left visual Inspection -SAT. TENSION COMPRESSION CRITERIA TEST 1 22.2 11.7 300.0 TEST 2 26.7 12.6 300.0 TEST 3 0.005 0.004 .02'gs TEST 4 26.1 15.4 300.0 TEST SAMPLE? YES SAMPLE CLASSSR DATE REINSTALLED: 04/19/05

TAG # SERIAL# .. PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S INSPECTION

SUMMARY

FUNCTIONAL TEST SUM_ . AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _.._.._,,_,._.._._.._.._.._.._,,_._.._.._.._.._.._.._.._.._.._....._.............C.C.C... C..C.-.......-.CI......C... C.._.._.._.._.._.._... 41084 23229 NWA 411912005 PASS 04/19105 PASS 12.750 PASS NO N/A Visual lnspection-SATt"L dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Spherical bearings and load pin STATUS PASS (NIA IF NOT PERFORMED) lubricated with neolube UTC 449261. As left visual Inspection -SAT. TENSION COMPRESSION CRITERIA TEST I 6.5 8.6 75.0 TEST 2 12.6 10.8 75.0 TEST 3 0.007 0.005 .02g's TEST 4 12.9 9.7 75.0 TEST SAMPLE YES SAMPLE CLASSSR DATE REINSTALLED: 04119105 4-1086 42386 N/A 4114/2005 PASS N/A N/A 27.5 PASS YES PASS VlsualInspectlon-SATLtDimenslon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRE SSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL # ,.tPLACE- VISUAL S FUNCTIONAL S L DIM EN S HAND. S - INSPECTION

SUMMARY

FUNCTIONAL TEST SUMi.-.AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1087 12994 N/A 411412005 PASS NiA N/A 27.687 PASS YES PASS VisualInspection-SAT,"L"Dimenslon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1088 12995 N/A 4115/2005 PASS N/A NA 26.562 PASS YES PASS VIsuallnspedion-SAT."LVDimenslon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS NIA (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL# tcPLACE. VISUAL S FUNCTIONAL S L DIMEN S HAND- S - INSPECTION

SUMMARY

FUNCTIONAL TEST SUMi._ CaY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T

                                                                                                                               ..             S...

4-1089 12996 NMA 4115/2005 PASS NIA N/A 26.50 PASS YES PASS Visuallnspection-SAT,'" Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1090 12997 N/A 4/16/2005 PASS N/A NIA 27.25 PASS YES PASS VIsuallnspectlon-SATLDimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Spherical bearings and load pin lubricated with neolube UTC STATUS NW.$A (N/A IF NOT PERFORMED) 449261. No I.D. tag installed. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG# SERIAL# o."PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND. S - - INSPECTION

SUMMARY

FUNCTIONAL TEST SUMu..).Y MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T

........  *.*... -. **.....    .... ...   ..... .. ...-   .....  ...........................               ....- .........................                 I.....  ...........-.....................            I..  ....................................

4-1 087 12994 NIA 411412005 PASS NWA NIA 27.687 PASS YES PASS Visual inspection-SAT.L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC #449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1088 1295 N/A 411512005 PASS NfA N/A 26.562 PASS YES PASS Visual Inspection-SAT,"LV Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IFNOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL # .PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S - INSPECTION

SUMMARY

FUNCTIONAL TEST SU.. -AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4.1091 12998 NWA 4116/2005 PASS N/A NWA 27.25 PASS YES PASS Visuallnspection-SAT,tL Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Spherical bearings and load pin lubricated with neolube UTC STATUS NWA (N/A IF NOT PERFORMED) 449261. No I.D. tag Installed. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS NIA DATE REINSTALLED: 4.1092 12999 N/A 4116/2005 PASS N/A N/A 26.50 PASS YES PASS VisualInspection-SAT,L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Spherical bearings and load pin lubricated with neolube UTC STATUS NIA (NWA IF NOT PERFORMED) 449261. No I.D. tag Installed. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLECLASSNMA DATE REINSTALLED:

TAGS SERIALOKeiLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S . - INSPECTION

SUMMARY

FUNCTIONAL TEST SUM,...AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T _.._..._.._.._I..........................................................................................................................m.........................................I...._.. 4-1091 12998 N/A 4116/2005 PASS N/A N/A 27.25 PASS YES PASS Visuallnspection-SATL Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Spherical bearings and load pin lubricated with neolube UTC STATUS N/A (NMA IF NOT PERFORMED) 449261. No I.D. tag Installed. TENSION COMPRESSION CRITERIA TEST 1 TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1092 12999 NMA 4116/2005 PASS N/A N/A 26.50 PASS YES PASS Visuallnspection-SAT L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable. Spherical bearings and load pin lubricated with neolube UTC STATUS NWA (N/A IF NOT PERFORMED) 449261. No I.D. tag Installed. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTAU

TAG # SERIAL # . -.PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S v-' INSPECTION

SUMMARY

FUNCTIONAL TEST SUN, AY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T .... _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._......_.... _..... .._.._.,_.._.. ..... _.,_a...*.

                                                                                                                                      .. _ _..- .. _          a.._.._,_...

4.1093 17868 N/A 4114/2005 PASS 04/14105 PASS 19.625 PASS NO N/A Visual Inspection-SAT,V dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Transition piece torqued to 35 ft. lbs. STATUS PASS (WA IF NOT PERFORMED) (Torque wrench M864, cal due 6/20105). Spherical bearings and load pin TENSION COMPRESSION CRITERIA lubricated with neolube UTC 449261. As left visual Inspection -SAT. TEST 1 85.3 103.8 750.0 TEST 2 94.5 141.3 750.0 TEST 3 0.005 0.007 .02 g's TEST 4 103.6 65.2 750.0 TEST SAMPLE? YES SAMPLE CLASS QR DATE REINSTALLED: 04/14/05 4-1094 18157 N/A 4/14/2005 PASS N/A 19.375 PASS YES PASS Visual Inspedion-SAT,L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL #I .. PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S - INSPECTION

SUMMARY

FUNCTIONAL TEST SUN,.. -RY MENT S/N INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1095 17870 N/A 4/15/2005 PASS N/A N/A 19.187 PASS YES PASS Visualinspection-SAT,VDimenslon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1096 17871 N/A 4/1512005 PASS N/A N/A 19.187 PASS YES PASS Visualinspection-SAT,VIDimensIon FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL% ...:PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S INSPECTION

SUMMARY

FUNCTIONAL TEST SUknralRY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4.1095 17870 NIA 4/15/2005 PASS N/A N/A 19.187 PASS YES PASS Visuallnspection-SAT,t" DImension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS NIA (NIA IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS NIA DATE REINSTALLED: 4-1096 17871 N/A 4/15/2005 PASS N/A N/A 19.187 PASS YES PASS Visuallnspection-SAT,"L Dimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449281. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIAL # ... PLACE- VISUAL S FUNCTIONAL S LDIMEN S HAND- S INSPECTION

SUMMARY

FUNCTIONAL TEST WM.._WRY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4-1097 17852 N/A 4/15/2005 PASS N/A N/A 19.625 PASS YES PASS Visuallnspection-SAT,"L"Dimension FUNCTIONALTEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1098 16252 N/A 4/15/2005 PASS N/A N/A 19.50 PASS YES PASS Visuallnspectlon-SATVDimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED:

TAG # SERIALi* X.+/-PLACE- VISUAL S FUNCTIONAL S L DIMEN S HAND- S' INSPECTION

SUMMARY

FUNCTIONAL TEST SUW...ARY MENT SIN INSPECT T INSPECT T T STROKE T DATE A DATE A A  ? A T T T T 4.1099 20894 N/A 4/12/2005 PASS N/A NMA 16.625 PASS YES PASS Visualrlnspectlon-SATVDimension FUNCTIONAL TEST PERFORMED? NO Acceptable, Handstroke-SAT. Spherical bearings and load pin lubricated with STATUS N/A (N/A IF NOT PERFORMED) neolube UTC # 449261. TENSION COMPRESSION CRITERIA TEST I TEST 2 TEST 3 TEST 4 TEST SAMPLE? NO SAMPLE CLASS N/A DATE REINSTALLED: 4-1100 29498 N/A 4/17/2005 PASS 04/17/05 PASS 10.625 PASS NO N/A Visual Inspection-SAT,L" dimension FUNCTIONAL TEST PERFORMED? YES acceptable and functional test -SAT. Snubber torqued to transition tube at STATUS PASS (N/A IF NOT PERFORMED) 120 In. Ibs.(Torque wrench E504, cal due 6/4105). Spherical bearings and TENSION COMPRESSION CRITERIA load pin lubricated with neolube UTC 449261. As left visual inspection -SAT. TEST 1 3.9 5.9 17.5 TEST 2 6.8 6.6 17.5 TEST 3 0.009 0.009 .02g's TEST 4 5.1 5.2 17.5 TESTSAMPLE? YES SAMPLECLASSSR DATE REINSTALLED: 04/17/05 i I

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE Summary of System Pressure Testing Attachment 5

TURKEY POINT UNIT 4 CYCLE 22 SYSTEM PRESSURE TESTING FINAL REPORT Owner: Florida Power and Light Company 700 Universe Blvd. Juno Beach, Florida, 33408 Plant: Florida Power and Light Company Turkey Point Nuclear Power Plant Unit 4 9760 SW 344h Street Homestead, Florida 33035 Commercial Service Date: September 7, 1973 Prepared by: <L_ 7LI2o _a Reviewed by: cA Date: 7/no/b Approved by: CDae .Date: !7/2 /'5= 1

Page 2 of 9 Abstract This report details the pressure testing of selected class 1, 2, and 3 piping and components of Florida Power and Light Company Turkey Point Unit 4. This report is for cycle 22 that includes the dates between 11/5/2003 to 6/13/2005. The refueling outage for cycle 22 occurred between 4/10/2005 to 6/13/2005. This pressure testing is being reported following the first outage of the first period for 4th ten-year interval for Turkey Point Unit 4. Piping and components were selected and tested in accordance with Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code "Rules for Inservice Inspection of Nuclear Power Components", 1998 Edition with 2000 addenda with specific relief as granted under 10 CFR 50.55a. Procedures The following Florida Power and Light (FPL) procedures and documents have been implemented to provide instructional guidance for the performance of the required ASME XI pressure testing and subsequent inspections. 4-OSP-041.25 RCS Overpressure Leak Testing 4-OSP-45.1 ASME Section XI Quality Group A Bolting Examination* 4-OSP-45.2 ASME Section XI Quality Group B Bolting Examination* 0-ADM-523 ASME Section XI Pressure Tests for Quality Group A, B, and C Systems/Components. 4-OSP-041.2 Reactor Coolant System Visual Leak Inspection and Leak Evaluation. NDE-4.2 Visual Examination VT-2 Conducted During System Pressure Tests.

  • Relief Request No 18, Use of Code Case N-533 Authorized for Turkey Point Units 3 and 4 (TAC NOS. M98149 AND M98150).

Page 3 of 9 System Summary: The following safety related Class 1, 2, and 3 systems, or sections thereof were pressure tested in accordance with the requirements of the 1998, 2000 addenda of ASME Section XI Code. System Name System Number Intake Cooling Water 19 Emergency Diesel Generators 22 Component Cooling Water 30 Spent Fuel pool Cooling 33 Reactor Coolant 41 Chemical Volume and Control System 47 Residual Heat Removal 50 Safety Injection System 62 Main Steam System 72 Auxiliary Feedwater 75 AcronVms: ADM: Administrative ASME: American Society of Mechanical Engineers CSS: Containment Spray System CCW: Component Cooling Water CVCS: Chemical Volume Control System ECC: Emergency Containment Cooler EDG: Emergency Diesel Generator FW: Feedwater HX: Heat Exchanger ICW: Intake Cooling Water NDE: Non Destructive Examination PWO: Plant Work Order PZR: Pressurizer RCP: Reactor Coolant Pump RHR: Residual Heat Removal RO: Restricting Orifice RV: Relief Valve RX: Reactor SFPC: Spent Fuel Pool Cooling SG: Steam Generator WO: Work Order

Page 4 of 9 Test Packafc Development The specific pressure test boundaries were selected after review of the applicable plant operating diagram/code boundary drawings. The piping systems were broken into sub-systems. The sub-systems were selected based on Technical Specifications operability requirements, acceptable isolation points and availability of test connections and vent valves. The sub-systems were then assigned test package numbers, which could be tested in entirety, or based on availability could be broken down further into numerous tests within the specific sub-system. The pressure test package numbers contain six (6) segments of information, Sample: 04-CCW-301 10-I-01 A A A A A A 1 2 3 4 56

1. Unit Number (00) common to both units 3 and 4. (03) Unit specific. (04)

Unit specific.

2. System abbreviation
3. System number [First (2) digits].
4. Sub-system number [(2) or (3) digits].
5. Type of test (H) Hydrostatic, (P) Pneumatic, (L) Leakage
6. Number of test performed within the specific sub-system.

Page 5 of 9 The following is a list of pressure tests that were performed during this cycle. They are sorted by system: INTAKE COOLING WATER. SYSTEM 19 04-ICW-19124-L-01 Test Date: 01/09/04 This test was performed due to the replacement of 4B ICW (4P9B), expansion Joint (XJ-4-1407), and check valve (4-50-321) and discharge elbow per WO#32004932-01. There was no leakage observed during this test. 04-ICW-19125-L-01 Test Date: 05/07/04 This test was performed due to the replacement of 4C ICW (4P9C), expansion Joint (XJ-4-1408), and check valve (4-50-331) and discharge elbow per WO#31021026-01. There was no leakage observed during this test. 04-ICW-19141-L-01 Test Date: 10/16/04 This test was performed due to the replacement of Valve 4-50-311 per WO#34017659-01. There was no leakage observed during this test. 04-ICW-19142-L-01 Test Date: 05/07/05 This test was performed due to the replacement of Valve 4-50-324 per WOH34001196-01. There was no leakage observed during this test. 04-ICW-19143-L-01 Test Date: 05/31/05 This test was performed due to the replacement of Valve POV-4-4882 per WO#34001760-01. There was no leakage observed during this test. 04-ICW-19144-L-01 Test Date: 05/31/05 This test was performed due to the replacement of Valve POV-4-4883 per WO#34004423-01. There was no leakage observed during this test. 04-ICW-19146-L-O1 Test Date: 04/29/05 This test was performed due to the replacement of Valve 4-50-329 per WO#34021438-01. There was no leakage observed during this test. 04-ICW-19147-I-O1 Test Date: 05/07/05 This test was performed due to the replacement of Valve 4-50-311 per WO#34017659-01. There was no leakage observed during this test.

Page 6 of 9 04-ICW-19149-L-01 Test Date: 04/29/05 This test was performed due to the replacement of Valve 4-50-349 per WO34021437-01. There was no leakage observed during this test. 04-ICWV-19150-L-01 Test Date: 05/07/05 This test was performed due to the replacement of Valve 4-50-309 per WO934011469-01. There was no leakage observed during this test. 04-ICNW-19152-L-01 Test Date: 04/29/05 This test was performed due to the replacement of Valve 4-50-350 per WO34021446-01. There was no leakage observed during this test. EMERGENCY DIESEL GENERATOR, SYSTEM 22 04-EDG-2254-L-01 Test Date: 9/19/04 This test performed due to replacement of the 4B EDG Air Start Piping per W0#34006575-02. There was no leakage observed during this test. COMPONENT COOLING WATER, SYSTEM 30 04-CCNW-30336-L-01 Test Date: 05/09/05 This test performed due to replacement of valve RV-4-1424 per WO#34003135-01. There was no leakage observed during this test. 04-CCW-30337-L-01 Test Date: 05/09/05 This test performed due to replacement of valve RV-4-1425 per WO34003140-01. There was no leakage observed during this test. 04-CCW-30338-L-01 Test Date: 05/09/05 This test performed due to replacement of valve RV-4-1423 per WO#34003107-01. There was no leakage observed during this test.

Page 7 of 9 CHEMICAL AND VOLUME CONTROL SYSTEM 47 04-CVCS-4750-L-01 Test Date: 04/10/05 This test was performed to meet the 1998 Edition 2000 Addenda of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test. 04-CVCS4751-L-01 Test Date: 04/10/05 This test was performed to meet the 1998 Edition 2000 Addenda of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test. 04-CVCS-4752-L-01 Test Date: 04/10/05 This test was performed to meet the 1998 Edition 2000 Addenda of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test. REACTOR COOLANT, SYSTEM 41 04-RCS-4111-L-01 Test Date: 06/03/05 This test involved the leakage test of the Reactor Coolant System piping inside containment following the Unit 4 Cycle 22 Refueling Outage. This leakage test also addressed the following replacements. Component WO# Replaced RV-4-551A 34001668-01 Remove, install spare RV-4-551B 34001669-01 Remove, install spare RV-4-551C 34001670-01 Remove, install spare 4P200C 34012046-01 Replace rotating element included pump flange No leakage was observed during this test. CHEMICAL AND VOLUME CONTROL, SYSTEM 47 04-CVCS-4785-L-01 Test Date: 11/13/05 This test was performed due to replacement of the 4C Charging Pump (4P201C) per WO#34002657-01. There was no leakage observed during this test. 04-CVCS4787-L-01 Test Date: 06/03/05 This test was performed due to replacement of valve 4-293A per WO#34015793-01. There was no leakage observed during this test. 04-CVCS4788-L-O1 Test Date: 06/03/05 This test was performed due to the piping modification of Valve RV-4-203 per PCM 04-063. There was no leakage observed during this test. 04-CVCS4789-L-01 Test Date: 06/03/05 This test was performed due to replacement of valve 4-293B per WOM34015794-01. There was no leakage observed during this test.

Page 8 of 9 MAIN STEAM, SYSTEM 72 04-SG-7214-L-01 Test Date: 04/10/05 This test was performed to meet the 1998 Edition 2000 Addenda of ASMvE Section XI periodic pressure Test requirements. No leakage was noted during this test. 04-SG-7215-L-01 Test Date: 04/10/05 This test was performed to meet the 1998 Edition 2000 Addenda of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test. 04-SG-7216-L-01 Test Date: 04/10/05 This test was performed to meet the 1998 Edition 2000 Addenda of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test. 04-MS-7226-L-01 Test Date: 6/3/05 This test was performed due to replacement of valve RV-4-1402 per WO#34022782-01. There was no leakage observed during this test. 04-MS-7227-L-01 Test Date: 6/3/05 This test was performed due to replacement of valve RV-4-1411 per WO#35007801-01. There was no leakage observed during this test. 04-MS-7228-L-01 Test Date: 613105 This test was performed due to replacement of the bonnet of valve RV-4-1400 per WO#34000320-01. There was no leakage observed during this test. 04-MS-7229-L-01 Test Date: 6/3/05 This test was performed due to replacement of the bonnet of valve RV-4-1401 per WO#34000319-01. There was no leakage observed during this test. 04-MS-7230-I-O1 Test Date: 06/03/05 This test was performed due to replacement of the bonnet of valve RV-4-1402 per WO34000318-01. There was no leakage observed during this test.

Page 9 of 9 BOLTED JOINT EXAMINATIONS As required by the ASME Section XI Code, bolted joints on systems that are borated for the purpose of controlling reactivity must have insulation removed to perform the VT-2 exam. Bolted joint exams are performed in accordance with 4-OSP-045.1 for class 1 components. Class 2 and class 3 bolted components are examined in accordance with 4-OSP-045.2. The class 1 inspection included all insulated class 1 bolted components. The class 2 and class 3 inspections consisted of all insulated bolted joints both inside and outside the containment. There are no class 3 bolted joints in borated systems inside containment. The following is a listing of all bolted joints identified with leakage during this inspection. All leakage was evaluated by engineering as required by ASME XI. Component: CR Number Code Class CV-4-310B 2005-10496 1 FE-4-127 2005-2005-9611 2 4-752A 2005-9611 2 4-754A 2005-9611 2 4-754B 2005-8945 2 4-757A 2005-9076 2 4-757B 2005-9076 2 4-757C 2005-9076 2 4-757D 2005-9076 2 4-759B 2005-9170 2 FCV-4-605 2005-9324 2 HCV-4-758 2005-9324 2 MOV-4-862B 2005-9611 2 RO-4-1469 2005-8945 2

TURKEY POINT UNIT 4 2005 REFUELING OUTAGE NIS-2 REPORTS

Abstract The attached NIS-2 reports detail the repairfeplacement of Class 1,2 and 3 piping and components for Florida Power and Light Company, Turkey Point Unit 4. These repairs or replacements were performed prior to and during the Spring 2005 refueling outage, between the dates of November 5, 2003 and June 13, 2005. Piping and components were inspected/tested in accordance with Section Xl of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel code "Rules for Inservice Inspection of Nuclear Power Components, "1998 Edition with Addenda through 2000.

NIS-2 Log Report No. Report Date Work Order Number ANII Certification Framtomc 5/31/2005 35003979 (50-5058250-00) 8/20/2005 35003759 (50-5042217-00) SGT 5/31/2005 35001449-05 8/22/2005 SGT 5/31/2005 35001449-06, 07,08, 09 8/22/2005 SGT 5/31/2005 35001449-04 8/22/2005 05-001-4 4/18/2005 35004907-02 8/8/2005 05-002-4 4/19/2005 34002657-01 8/8/2005 05-003-4 4/20/2005 34013950-01 8/8/2005 05-005-4 4/20/2005 34011621-01 8/8/2005 05-005-4 4/21/2005 31011026-01 8/8/2005 05-006-4 5/4/2005 32005681-01 8/5/2005 05-007-4 5/5/2005 34015515-01 8/8/2005 05-008-4 5/5/2005 34017659-01 8/8/2005 05-009-4 5/5/2005 32020056-01 8/8/2005 05-010-4 5/5/2005 34021446-01 8/6/2005 05-011-4 5/5/2005 34021437-01 8/8/2005 05-012-4 5/6/2005 34011470-01 8/8/2005 05-013-4 5/7/2005 33021448-01 8/18/2005 ____ ___CR ___ ____ 03-3733 05-014-4 5/7/2005 34011650-01 8/6/2005 05-015-4 5/7/2005 34003100-01 8/6/2005 05-016-4 5/7/2005 34002347-IA 8/22/2005 05-017-4 5/7/2005 33021588-01 8/6/2005 05-018-4 5/7/2005 34006575-02 8/22/2005 05-019-4 5/7/2005 32004932-01 8/6/2005 05-020-4 5/9/2005 31020696-01 8/6/2005 05-021-4 5/9/2005 35007926-01 8/6/2005 ___ ______ ___ ___ ___C R 0510946 __ _ _ _ _ __ _ _ _ _

NIS-2 Log Report No. Report Date Work Order Number ANIT Certification 05-022-4 5/10/2005 34011721-01 8/6/2005 05-023-4 5/11/2005 34003107-01 5/17/2005 05-024-4 5/11/2005 34003135-01 5/17/2005 05-025-4 5/11/2005 34003140-01 5/18/2005 05-026-4 5/10/2005 31020697-01 8/6/2005 05-027-4 3/3/2005 34001196-01 6/9/2005 05-028-4 5/11/2005 34011469-01 8/5/2005 05-029-4 5/11/2005 34021438-01 5/18/2005 05-030-4 5/13/2005 34003027-01 8/8/2005 05-031-4 5/12/2005 33017656-01 8/6/2005 05-032-4 5/16/2005 33017571-01 8/5/2005 05-033-4 5/16/2005 35000367-01 8/17/2005 05-034-4 5/23/2005 34011774-01 8/5/2005 05-035-4 4/25/2005 34009352-02 8/18/2005 05-036-4 6/20/2005 34022782-01 8/20/2005 05-037-4 6/22/2005 32014491-01 8/17/2005 05-038-4 6/20/2005 34001760-01 8/5/2005 05-039-4 6/20/2005 34004423-01 8/5/2005 05-040-4 6/20/2005 35007801-01 8/20/2005 05-041-4 6/21/2005 34000320-01 8/18/2005 05-042-4 6/21/2005 31019878-01 8/5/2005 05-043-4 6/21/2005 34015793-01 8/4/2005 05-044-4 6/21/2005 34015794-01 8/22/2005 05-045-4 6/22/2005 35012855-02 8/18/2005 05-046-4 6/22/2005 34011623-02 8/4/2005 05-047-4 7/6/2005 34000319-01 8/19/2005 05-048-4 6/23/2005 35012782-01 8/4/2005

NIS-2 Log Report No. Report Date Work Order Number ANII Certification 05-049-4 6/23/2005 35003504-01 8/4/2005 05-050-4 6/23/2005 34001672-01 8/4/2005 05-051-4 6/23/2005 35010877-01 6/23/2005 05-052-4 6/23/2005 33019910-01 7/25/2005 05-053-4 6/23/2005 3501-36-01 8/18/2005 05-054-4 6/23/2005 35007973-01 7/25/2005 05-055-4 6/28/2005 33019898-01 8/17/2005 05-056-4 6/29/2005 34011651-01 8/18/2005 05-057-4 6/28/2005 34011649-01 8/18/2005 05-058-4 6/28/2005 34012259-01 8/18/2005 05-059-4 11/25/2004 34000318-01 8/19/2005 05-060-4 7/6/2005 35003432-01 8/18/2005 05-061-4 7/12/2005 34001668-01 8/17/2005 05-062-4 7/7/2005 34001669-01 8/17/2005 05-063-4 7/7/2005 34001670-01 8/17/2005 05-064-4 7/12/2005 35000440-01 8/17/2005 05-065-4 7/12/2005 34012046-01 8/19/2005 05-066-4 7/12/2005 34012046-01 8/18/2005 05-067-4 7/13/2005 34003357-01 8/18/2005

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI

1. Owner Florida Power & Liaht Co. Date: _

Mav 31 2005 Nare 700 Universe Blvd., Juno Beach, Fl, 33408 Shcet I of 5 Address

2. Plant Turkev Point Nuclear Power Plant Unit 4 Name W035003979, 50-50S8250-00 (FANP) 9760 SW 344th St.. Florida Citv. FL 33035 WO 35003759. 50-5042217-00 (FANP)

Address Repir/Replaeemnt Organizatba P.O.DMiebo.. etc.

3. Work Performed by Framatome-ANP, Inc. Type Code Symbol Stamp NtA Narm Authorization No. N/A 3315 Old Forest Road. Lvnchburg VA 24501 Expiration Date N/A Address
4. Identification of System Reactor Vessel (0431
5. (a)Applicable Construction Code ASME III . 1989 Edition, No Addenda, N-474-2 Code Case yaw (b)Applicable Edition of Section X1 Utilized for Repalr/Replacement Activity 1998 a 2000 2142-1 Year 2143-1 (c)Appilcable Section X Code Cases None N-588 N-461
6. Identification of Components:

Name of Name of Manufacturer National Year Corngded. ASW.5E Code component Manufacturer Serial No. Board No. Other Identification Built Rtt o Stare d __ __ _ _ _ __ _ __ __ __ __ _ _ _ __ _ _ _ _ _ _(Yes or Nol Reactor Framatome CCITUO02 N/A N/A 2005 Installed Yes Head ANP CRDM Jeumont 2661 N/A G-13145 2004 Installed Yes CRDM Jeumont 2662 N/A M-6/32 2004 Installed Yes CRDM Jeumont 2663 N/A L-7116 2004 Installed Yes CRDM Jeumont 2664 N/A K-8/7 2004 Installed Yes CRDM Jeumont 2665 N/A D-10/36 2004 Installed Yes CRDM Jeumont 2666 N/A H-6/8 2004 Installed Yes CRDM Jeumont 2667 N/A J-5117 2004 Installed Yes CRDM Jeumont 2668 N/A L-5/27 2004 Installed Yes CRDM Jeumont 2669 N/A K-2765 2004 Installed Yes CRDM Jeumont 2670 N/A J-3141 2004 Installed Yes CRDM Jeumont 2671 N/A H-4124 2004 Installed Yes CRDM Jeumont 2672 N/A G-5/18 2004 Installed Yes

7. DescripUon of Work Installed new Reactor Head and Contro Rod Drive Mechanisms fCRDM) and RVH Vent Line,
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Norninal Operating Pressure 0 ExemptO Other I Pressure 22S psi Test Temp. °ir NOTE: Supptement&I sheetsIafrm oftirts,sketchsc, ordrawings may beusd provided (1)sloeIsS h x i'k.(2) Inforation InIems I shaa 6of thisrepor0 IsIndulded on ach sKeI, and (3) aci sheedis amunbered andnumber ofheetssb recorded A the top of sis form (7/99) This formn(E0030) may beobtained from theOrder Dept, AE , 22 LowDriveBox u 2300,PafrileKdNJ 07007.2300.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI

1. Owner Florida Power & Light Co. Date: May 31. 2005 Narne 700 Universe Blvd.. Juno Beach. FL 33408 Sheet 2 of 5 Addrtss
2. Plant Turkey Point Nuclear Power Plant Unit 4 Name W035003979, 50-5058250-00 (FANP) 9760 SW 344th St. Florida Citr, FL 33035 WO 35003759. 50-5042217-00 (FANP)

Address ReqaV.acp1vwMe Orgetitiont.O. Box. Job No., etc.

3. Work Performed by Framatome-ANP. Inc. Type Code Symbol Stamp N/A Name Authorization No. N/A 3315 Old Forest Road. Lvnchburg VA 24501 Expiration Date N/A Address
4. Identification of System Reactor Vessel (0431
5. (a)Applicable Construction Code ASME III . 1989 Edition, No Addenda, N-474-2 Code Case Year (b)Applicable Edition of Section Xl Utilized for Repair/Reptacement Activity 1998 a 2000 2142-1 Yeo' 2143-1 (c)Applicable Section Xl Code Cases None N-588 N-461
6. Identification of Components:

Name of Name of Manufacturer Natonal Year Ccrrected. AS ME code component Manufacturer Serial No. Boardr No. Other Identification Built orcftOed. Sto4Ned CRDM Jeumont 2673 NIA L-9/15 2004 Installed Yes CRDM Jeumont 2674 N/A F-2/66 2004 Installed Yes CRDM Jeumont 2675 N/A J-1 1/14 2004 Installed Yes CRDM Jeurnont 2676 N/A H-1 2122 2004 Installed Yes CRDM Jeumont 2677 N/A H-I 0/6 2004 Installed Yes CRDM Jeumont 2678 NIA F-4/34 2004 Installed Yes CRDM Jeum.ont 2679 N/A F-1237 2004 Installed Yes CRDM Jeumont 2680 N/A G-14/21 2004 Installed Yes CRDM Jeumont 2681 N/A H-8/1 2004 Installed Yes CRDM Jeumont 2682 NIA E-1 1/29 2004 Installed Yes CRDM Jeumont 2683 N/A E-9.20 2004 Installed Yes CRDM Jeumont 2684 N/A F-1/2 2004 Installed Yes CRDM Jeumont 2685 N/A M-8/123 2004 Installed Yes CRDM Jeumont 2686 N/A K-4/33 2004 Installed Yes CRDM Jeumont 2687 N/A P-6/64 2004 Installed Yes

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI

1. Owner Florida Power & Liaht Co. Date: May 31. 2005 Nan_

700 Universe Blvd., Juno Beach, FL 33408 Sheet 3 of 5 Address

2. Plant Turkey Point Nuclear Power Plant Unit 4 Name W035003979,50-5058250-00 (FANP) 9760 SW 344th St. Florida City, FL 33035 WO 35003759.50-5042217-00 (FANP1 Address ReqirRepixemnw Orspanizate P..

M Boy, Job NO..etc.

3. Work Performed by Framatome-ANP. Inc. Type Code Symbol Stamp N/A Name Authorization No. N/A 3315 Old Forest Road. Lvnchburg Va 24501 Expiration Date N/A Address
4. Identification of System Reactor Vessel (043)
5. (a)Applicable Construction Code ASME III . 1989 Edition, No Addenda, N.474-2 Code Case (b) Applicable Edition of Section Xl Utilized for RepalrlReplacement Activity 1998 a 2000 2142-1 Yar 2143-1 (c)Applicable Section Xl Code Cases None N-588 N-461
6. Identification of Cornmonents:

Name of Name of Manufacturer Nauonat Year Correted. ASMECode component Manufacturer Serial No. Board No. Other Identification Built remeved. sorwed CRDM Jeumont 2688 N/A N-7/40 2004 Installed Yes CRDM Jeumont 2689 N/A F-14/69 2004 Installed Yes CRDM Jeumont 2690 N/A K-14162 2004 Installed Yes CRDM Jeu.ont 2691 N/A P-10/63 2004 Installed Yes CRDM Jeumont 2692 NIA N-9/39 2004 Installed Yes CRDM Jeumont 2693 N/A 1- 1126 2004 Installed Yes CRDM Jeumont 2694 N/A K-112630 2004 Installed Yes CRDM Jeumont 2695 NtA M-10/31 2004 Installed Yes CRDM Jeumont 2696 N/A J-13/38 2004 Installed Yes CRDM Jeumont 2697 NIA G-3/42 2004 Installed Yes CRDM Jeumont 2698 N/A B-10/68 2004 Installed Yes CRDM Jeumont 2699 N/A 0-8/25 2004 Installed Yes CRDM Jeumont 2700 N/A C-7/43 2004 Installed Yes CRDM Jeumont 2701 N/A D-6/35 2004 Installed Yes CRDM Jeumont 2702 NIA C-9144 2004 Installed Yes CRDM Jeumont 2634 NIA E-7/19 2004 Installed Yes CRDM Jeumont 2636 NIA I E-5/70 2004 Installed Yes CRDM Jeumont 2654 N/A B-6/67 2004 Installed Yes

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI

1. Owner Florida Power & Light Co. Date: May 31. 2005 Name 700 Universe Blvd_ Juno Beach, FL 33408 Sheet 4 of 5 Address
2. Plant Turkey Point Nuclear Power Plant Unit 4 Na9Fe W035003979, 50-5058250-00 (FANP) 9760 SW 344th St.. Florida Clit, FL33035 WO 35003759. 50-5042217-00 (FANP)

Address RXeP-fiRcp ltI Organiamaon P.O.Box, JobNo..ect,

3. Work Performed by Framatome-ANP. Inc. Type Code Symbol Stamp N/A Name Authorization No. N/A 3315 Old Forest Road. Lvnchburg Va 24501 Expiration Date N/A Address
4. Identification of System Reactor Vessel (043)
5. (a) Applicable Construction Code ASME III . 1989 Edition, No Addenda, N-474-2 Code Case (b)Applicable Edition of Section Xl Ulized for RepairlReplacement Activity 1998 a 2000 2142-1 yeo 2143-1 (c) ApplIcable Secton Xl Code Cases None N-588 N-461
6. Identification oComponents: _______

Name of Name of Manufacturer National Year Corrected ASUE Code component Manufacturer Serial No. Board No. Other Identificatlon Built RereMdVK stodN RVH Plug Jeumont JT 29 N/A B-8161 2004 Installed Yes RVH Plug Jeumont JT 30 N/A H-14/58 2004 Installed Yes RVLMS FmatmeAW 1430-C7DC NIA H-2/60 N/A Installed Yes RVLMS FanutoANP 1430B3YP N/A P-8159 NIA Installed Yes CETNA -0304001 BFrawtoA. N/A N-1 1151 NIA Installed Yes CETNA F A B -0304002 N/A L-3/53 NIA Installed Yes CETNA 0 FranutomeAn B-0304004 NIA C-5155 NIA Installed Yes CETNA Frarretlorre-IP B-0304005 N/A E-1 3/57 NIA Installed Yes Orsfice 0 FranlcmeAP Ht# U DY N/A UTC 0000460054 NIA Installed Yes Restricting 1 Coupling Ftom.ANP Ht# JKN N/A UTC 0000463581 N/A Installed Yes 60014#Reducer 0 FanBe-ANP Ht# HLF N/A UTC 0000452323 NIA Installed Yes 1 RaIsed O Frafrmome.AP Hi# NIA UTC 0000460056 N/A Installed Yes Rlange 2561ANE ____ 1' Globe Valve 0 Fma-tmAWp 69AZK N/A UTC 0000459719 NIA Installed Yes 1"S/S Pipe 0 FrarrmtomemP Ht #437948 N/A UTC 0000455385 N/A Installed Yes V Raised F kxne-ANp Ht#31438 N/A UTC 0000465376 NIA Installed Yes Flange _ 1' 45° Elbow 0 Fbn.e.ANP Ht# AP4 N/A UTC 0000464838 NIA Installed Yes 1- 900 Elbow 0 FaretorANP Ht# XR N/A UTC 0000460918 NIA Installed Yes 1 SIS Pipe 0 FamtDme-Atp Ht# 437948 NlA UTC 0000464959 N/A Installed Yes 0 = Installed by Framatome-ANP, customer (FP&L) supplied material (see UTC #)

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI Sheet 5 of 5 WO#35003979 WO#35003759 FORM NIS-2 (Back) 9 Remarks: N-2 forms for the Reactor Head and CRDMs are attached. Applicable Manufacturer's Data Reports to be attached ThA ITC nimhers for the rnlacepmnnt CRDMs nre. in order of annearance in table, 0000464049. 0000464050. 0000464051,0000464052.0000464053.0000464054, 0000464055.0000464056, 0000464057. 0000464058. 0000464059, 0000464060. 0000464061. 0000464062. 0000464063, 0000464064. 0000464065.0000464066. 0000464067. 0000464068. 0000464069.0000464070.0000464071.0000464072.0000464073.0000464074. 0000464075. 0000464076. 0000464077. 0000464078. 0000464079. 0000464080. 0000464081. 0000464082. 0000464083, 0000464084. 0000464085. 0000464086. 0000464087. 0000464088. 0000464089, 0000464090. 0000464091.0000459806.0000459808.0000459826.0000459845, 0000459845.0000464160.0000464159. 0000464094. 0000464094. 0000464094. and 0000464094. 0000460054. 0000452323, 0000460056. 0000463581. 0000459719. 0000455385. 0000464108. Comrlete new reactor head assembly was Pressure tested by a system leakage test. UTC numbers, for each Item In the order listed:PLUGs. 0000459845. 0000459845. RVLMS 0000464160. 0000464159. CETNAs. 0000464094. 0000464094. 0000464094. and 0000464094, CERTIFICATE OF COMPLIANCE I certify that the statements made Inthe report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp NI I A - Certificate of Authorization No. tlIl - Signed S= 1i Si Date &I I a 20.25 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Florida and employed by HSB CT of Hartford, C have Inspected the components described In this Owner'sReportdurlngtheperiod S_-___ _ _ __ _ _ _ to_ _ __o____4__ _______, and state that to the best of my knowledge and bellef, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. conceming the examinations and corrective measures described In this Owner's Report. Furthermore, nether the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                               '151t-"

Inspector's Signature Commissions ' 477,41 AC, I-) National Board, State, Province, and Endorsements Date _ ?_ z__0_

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI

1. Owner Florida Power & Light Co. Date May 31 2005 Name 700 Universe Blvd., Juno Beach. Fl 33408 Sheet I of 2 Address
2. Plant TurkevPoint Nuclear Power Plant Unit 4 Nane 9760 SW 344th Street, Florida City, FL 33035 WO #35001449, Task 5 Address IetidrIcplacenent Organization P.O.Box, JobNo., Cec.
3. Work Performed by _SGT, Inc Type Code Symbol Stamp _N/A Name Authorization No. __NIA

_7207 IBM Drive, Charlotte, NC 28262_ Expiration Date _ N/A Address

4. Identification of System _ Containment Structure - Concrete (51)
5. (a)Applicable ConstrucUonCode ACI 318 Edition, 1963 Addenda, NfA Code Case Yew (b)Applicable Edition of Section Xl tlized for RepairtReplacement Activity 1992 a1992 yew (c) Applicable Section Xl Code Cases ___NIA__
6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, Removed. ASME Code Starrved (Yes component Manufacturer Serial No. Board No. Other Identification Built Insted. or omNo) Containment Bechtel N/A N/A Reactor Building Wail 1970 Corrected No Structure

7. Description of Work:

As part of the Turkey Point Unit 4 Reactor Vessel Closure Heed (RVCH) Replacement Project, a portion of the reactor building containment wall was removed to provide an opening through which the original and replacement RVCH were moved. Existing concrete was removed by hydro-demolition. The wall was reconstructed by re-installing existing reinforcing using swage coupler splices and fusion welding. Both existing reinforcing and new reinforcing was installed. Sheathing was placed Inthe wall to reconnect the existing tendon sheaths. A new reinforcing mat using #11 Grade 60 steel was Installed on the Inner (liner plate side) face of the wall to carry tensile forces created upon restoration of the post-tensioning system In the wall. Grout was used to repair approximately 360 square feet adjacent to the opening In a thin layer (3' to 6', one small area depth was 91).

8. Tests Conducted: Hydrostatic 03 Pneumatic 0 Nominal OperatinS PressureO ExemptO Othiler ILRT Pressure_42. psi TestTemp.K0F NOThSupeameentol shms,Inform oefliss, or drawings skeicb#4 may betsed,Provided S K II in, (2)intormdon Inhems (1)sizeIs I throuh 6of thisretweh Included oneach shem atd (3) ncah shect isnumbered Isreorded t thetopof ths ~Im tnd nester orsheets J Remarks: Other Items installed are as follows:

Applicable Manufacturers Data Reports to be attached Name of UTC Other Identification Component Number Inside Rebar Mat 0465913, 0465914 N/A 65905

                                                                 .0465906, 0458984 0459131, 0463804.0459629, Concrete                 0465436,0465935, 0459944, 0466073 N/A 0465983, Grout                0463941,0465734, 0461504. 0464013 Rebar Couplers                 0000464444                          N/A SIze 9             ________________

Rebar Couplers 0000464445 N/A size 11 _ _ _ _ _ _ I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI FORM NIS-2 (Back)

9.0 Remarks

Continued Page 2 of 2 WO#35001449-05 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requirements of the ASME Code. Section XI. Type Code Symbol Stamp N l I-Certificate of Authorization No. miI I14-Signed I[SI _ Date & lI 20QS CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Florld and employed by HSB of Hartford have Inspected the components described In this Owner's Report during the period .3 .z4 - Osl to '- 2z < _____ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report Inaccordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                            </

7"<' Comrnissions r4 477 (S, C,jC1/4) Inspector's Signature National Board, State, Province, and Endorsements Date

FORM NIS-2 OWNERWS REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI

1. Owner Florida Power & Likht Co. Date Mav 31. 2005 Narne 700 Universe Blvd., Juno Beach, Fl 33408 Sheet I of 2 Address
2. Plant Turkey Point Nuclear Power Plant Unit 4 9760 SW 344tb Street. Florida City. FL 33035 WO #35001449, Task 6,7',8,9 Address Repsk/Rcplacement Orpanizslon P.O. SOX.job No.. tic.
3. Work Performed by _SGT, Inc Type Code Symbol Stamp NIJ Narna Authorization No. NA 7207 IBM Drive, Charlotte, NC 28262 Expiration Date N/ A Address
4. Identification of System Containment Structure Tendon System (51)
5. (a) Applicable Construction Code ACI 318 Edition, 1963 Addenda, NIA Code Case (b)Applicable Edition of Sectlon XIUtilized for RepairlRoplacernent Activity 1992 a1992 Ye(X (c) Applicable Section XI Code Cases _-____NA_______
7. Description of Work.

As part of the Turkey Point Unit 3 and 4 Reactor Vessel Closure Head (RVCH) Replacement Project, a portion of the reactor building containment wall was removed to provide an opening through which the original and replacement RVCH were moved. Eisting tendons (40 horizontal, 10 vertical) In the opening were removed and discarded and new tendons Installed through new tendon sheaths spliced to the existing sheathing. Additionally, twelve horizontal tendons and one vertical tendon adjacent to the opening were removed and replaced. New anchorheads (stressing washers) were Installed on shop ends and field ends of replaced tendons. For vertical tendons adjacent to the opening that were detensloned, new anchorheads were Installed on shop ends and existing field end anchorheads were re-used.

8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure D ExemptO Other0 ILRT Pressu 49.9 psi Test Tenp.8£F NOMN Supplmentsu sxets In brome,
                                  *r1t" Aeche%. or dhwin maybeused. providd (1) a IsS x1I In.. (2) ibrrnution inbIens I through6 oht s rqeon IsIncludedect eon sheet. and() eachstd ti auered andnumber  afsce Is recorded xthe wpp fth, ban
9. Remarks: Other items Installed are as follows:

Applicable Manufacturer's Data Reports to be attached Name of UTC te dntfcto Component Number OtherIdentficaton 52 Horizontal Mk# 15H33 thru 15H58 Tendons See Below Mk# 62H33 thru 62H58 11 Vertical S BeIwMk# 61V12 thru 61V21 Tendons ee elow . Mk# 61V5 171 460709,460500,464965 Heat Codes Anchorheads 463859,461305 See Below 465218,465205,465217, Heat Codes: AB, AC, AE, Shim Sets 465218,464717 AF, AG TendonGrease 464551,464593, Lot # 504637,520265

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI FORM NIS-2 (Back)

9.0 Remarks

Continued Page 2 of 2 WO#35001449-06.07,08 & 09 Tendon UTC Numbers(in order): 464965. 464965.4464965. 463859. 464965.464965. 463859. 464965. 464965. 464965.464965. 463859.464965. 463859. 463859. 464965. 463859.4464965. 463859. 464965. 463859.463859. 463859. 463859. 463859.463859. 463859.463859. 463859 463859. 463859. 463859.463859. 463859, 463859.463859.463859.463859. 463859. 463859.463859. 463859.463859. 464965 463859. 463990. 463989. 463988. 463987. 463986.463985.463984. 463983, 463982.463981.465260. 464810, 464811.464812. 464591. 464590. 464589. 463996. 464591.463996. 464589. 463995. 463995.463994. 463993. 463992.463995. 463994.463995. 463994. 463994.463993. 463994. 463990.464815. 464815.464816. 464813.464814. 464813. 463995. 463992.464591. 463992.464003. 463996. 463995. 463995. 464589. 463992. 464590.464589. 463992.463995. 463995.463995. 463996, 463995. 463994.463995. 464810. 464811.464817 Anchorhead Heat Codes: TD143. TD147. TD152. TD107. TD153. TDI5I. TD121. TD146. TDI50. TD142. TD156. TD106. TD141. TD134. TDIII. TD149. TD126. TD154. TD125. TD130. TDII0. TD119. TDI17. TD137. TD193. T11D8. TD104. TD192. TD115. TD95. TD85. TD127. TD113. TD84. TD80. TD124. TD91. TD120. TD116. TD105. TD112. TD100. TD88. TD132. TD128. TD19. TD145. TD37. TD131. TD121. TE26. TD12. TDI39. TD22. T624. TD42. TD136. TD15. TD135. TD13. TD1108. TD20. TD83. TD27. TD144. TD90. TD49. TD56. TD123. TD81. TD114. TD63. 31D109. TD94. TEI. TD99. TE37. TD101. TE5. TD59. TD37. TD58. TE7. TD55. TD30. TD72. TE15. TD75. TEIS. TD62. TE12. TD57. TE50. TD06. TE51. TD04. TE16. TD79. 1E32. TD78. TE42. TD74. TFA5. TD87. TE13. TD86. T133. TD30. TE22. TD46. TE21. TD03. TE3. TD50. TD133. TD140. TD60. TD53. TD103. TD71. TD67. TD51. TD98. TD129. TD96. TD58. TE46. TD09. 1T41. T1)48. TD43. TD66. T136. TD17. TE6. TD76. TE38. TD54. TE49. TD65. TE35. TD65. TE40. TD02. TE27. TW69. TE4. TD47. TE14. TD10. TE44. TD102. TE9. TD77. TE31. TD81. TE20. TD70. T147. TD67. TE29. TD07. TE2. TD69. TE23. TD50. TD89. TD73. TD138. TD53. TD122 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp N I Certificate of Authorization No. tq J Signed 'S1 SOpC!R t5SO Date 8 I1I 20_C CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Florida and employed by H3 CT of Hartford. CT have Inspected the components described In this Owner's Report during the period 3-z4-o to 8- Pt-Rv . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _ _ __ _ _ _commissions f -77 (4, c.g, f Inspector's Signature National Board, State, Province, and Endorsements Data rF Us mu

                                 °                          .

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI

1. Owner Florida Power & Lfght Co. Date -

May 31. 2005 Name 700 Universe Blvd., Juno Beach, Fl 33408 Sheet I of 2 Address

2. Plant Turkey Point Nuclear Power Plant Unit 4 Namne 9760 SW 3 44 th Street, Florida City. FL 33035 _WO #35001449, Task 4 Address ReptWRepiaunsem Organizaioe P.O. Box. Job No, etc.
3. Work Performed by _SGT, Inc Type Code Syrmbol Stamp NIA Name Authorization No. N/A 7207 IBM Drive, Charlotte, NC 28262 Expiration Date N/A Address
4. Identification of System Containment Structure - Liner Plate (51)
5. (a) Applicable Construction Code ASME Sec. ViI1 Edition, 1965 Addenda, _fLALCode Case Ywa (b) Appoicable EidUonof Section Xl Ulized forRepalr/ReplacementAcrity 1992 a1992: 5610-C-47 Rev2 (for NDE work)

(c) Applicable Section XI Code Cases N/A

7. Description of Work:

As part of the Turkey Point Unit 3 and 4 Reactor Vessel Closure Head (RVCH) Replacement Project, a portion of the reactor building containment wall was removed to provide an opening through which the original and replacement RVCH were moved. The existing liner plate was taken out of the opening and subsequently re-installed. The channel and angle steel connected to the liner plate for stiffening was re-installed with new material for splices across the liner plate seam welds. Alignment nuts used on the inside of the liner plate remain in place following re-installation of the existing liner plate. Additional new liner plate replaced damaged liner plate adjacent to the construction opening and couplings and pipe caps remained in place following grout placement.

8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Noninal Operating Pressure D ExemptO Other0 ILRT Prcssure 49.9psi TestTenp. 800F NOTE: Suppiemeuld<<sects"in rmrmfsts, skricchas, ord xmtswaybeused,prvd (I) *se Is1 K 11i", ln..(2)Inftt> in rtems I tugh6ofthistrepoftIs Incuded on ed shoel,and (3) each shopIsnumbered Wadnumber otsheeu i recorded atshe topofthis Itmr
9. Remarks: Other Items installed are as follows:

Applicable Manufacturers Data Reports to be attached Name of UTC Other identification Component Number __________ C5 x 6.7 0459738 N/A Channel 0464450 C8 x 11.5 0459736 N/A Channel _ _ _ _ _ _ _ _ _ _ 0459739 L3x2x114 0465710 N/A 0459731 Flat Bar 0459740 V1 I Y.' 0465716 N/A 4 40459737 X 14'____ Plate ___ 0459764 04572986 _ _ _ N/A_

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section XI FORM NIS-2 (Back)

9.0 Remarks

Continued Page 2 of 2 WO#35001449-04 Component uTC Other Identification Blank Nuts 0464452 N/A W Plate 0459733 NIA 1 2' 3000# 0465879 NIA Couplings _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Grout Port 0465878 NIA Plug ___ __ __ _ _ _ 2'3000# 46lNA Pipe Cap 0461NA CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp El I 14 Certificate of Authorization No. INe11w Signed A _ ISLE Su-wLS Date 8 II a 20-5.C CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Florida and employed by iHB of Hartford. CT have Inspected the components described In this Owners Report during the period 3 -Z O4- to 0 ?-24 S ____ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described Inthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Insiig us N ona Inspector's Signature National Board, State, Province, and Endorsements n:,f. f-Zr - o,- vdaB

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 4118/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 35004907-02 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Orgerzetion, P.O. No, Job No, etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NWA Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Spent Fuel Pit Cooling System #: 33 Quality Group C
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda. N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4B Spent Fuel Pit Cooling Pump N/A N/A N/A 4P212B N/A Corrected N
7. Description of Work:

Replaced the pump casing bolting on pump

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature NWA deg F 05-001-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration D ate: N/A Signed _ g o d - _ Date 5_ Owrler or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT pf Hartford. Connecticut, have-inpe ted the components described Inthis Owners Report during the period of____ _4 _ to t/cs and state that to the best of my knowledge and belief, the Owner has perfor ed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be riable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _ -___ Commissions 4 (7 c, 1 Inspector's Signature Natonal Board. State, Providence, and Endorsements Date_____ 05-001-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 41/ 19/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34002657-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair organIzation, P.o. No, Job No., etc.
3. Work Performed by - Florida Power and Ught Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NWA
4. Identification of System: CVCS Charging and Letdown System #: 47 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4C Charging Pump N/A N/A N/A 4P201 C Installed N
7. Descripton of Work:

Replace power frame, Including block, stuffing box, and valves, of 4C Charging Pump

8. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 2320 psig Test Temperature 99 deg F 05-002-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: NIA Signed i IS Date 4 1X 5 ) ° d; Owner or Owneres Designee, Title' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have I peted the components described in this Owners Report during the period of A2-79 to /F C and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners! Report In accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. X Inpct7 gna Commissions 4 4 ,c, Inspector's Signature National Board, State, Providence, and Endorsements Date e___ ___ 05-002-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl 1.Owner Florida Power and Light Co. Date 4r,?0120D5 Name. 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address

2. Plant Turkey Point Plant Unit 4 Name WO#: 34013950-01 CRU: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No.. etc.

P

3. Work Performet I b) Florida Power and Light Co. Type Code Symbol Stamp NWA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Component Cooling Water System #: 330 Quality Group C
5. (a)Applicable Construction Code B31.1 1955 Edition, NIA Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda. NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4C CCW Heat Exchanger N/A N/A N/A 4E207C N/A Corrected N
7. Description of Work:

Replace bolting of channel head

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure NIA psig Test Temperature N/A deg F 05-003-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed Date 4 Y qs Owner or Owner's Designee, Tle CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford. Connecticut, have InspVted the components described In this Owners Report during the period of / -e to F - f_- o and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be fiable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions A Zi77(4, C; M,.27) Inspector's Signature National Board. State. Providence. and Endorsements Date J7 At 05-003-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 4/20/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address Turkey Point Plant Unit 4
2. Plant Name WO#: 34011621-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No, Job No.. etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Component Cooling Water System #: 30 Ouality Group C
5. (a)Applicable Construction Code 831.1 19 55 EdItion, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda. N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Relief Valve for CCW Return N/A N/A N/A RV-4-71 5 N/A Corrected from Excess Letdown HX N
7. Description of Work:

Replace flange bolting during valve removal for testing

8. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure N/A Other NIA Pressure N/A psig Test Temperature N/A deg F 05-004-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. NfA Expiration Date: NWA Signed I&1 Date _ _I_._IOs Owner or Owner's Designee, Titld CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, a e Inspected the components described In this Owners Report during the period of 4.17-0S to 70-r and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Impiled, conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. ____________ Commissions AI 177? ,c, -ZJ Inspector's Signature National Board, State, Providence, and Endorsements Date _______ 05-004-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 4/21/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 31011026-01 CR#: N/A 9760 SW 344 Street Florida CIty, FL 33035 Address Repair Organization, P.O. No, Job No. etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NWA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Intake Cooling Water System #: 19 Quality Group C
5. (a)Applicable Construction Code B31.1 1955 Edition. N/A Addenda, NIA CodeCase (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda. N/A CodeCase
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4C Intake Cooling Water Pump N/A NA N/A 4P9C N/A Installed N Check Valve N/A NIA NIA 4-50-331 NtA Installed N Expansion Joint N/A N/A N/A XJ-4-1408 N/A Installed N
7. Description of Work:

Replace Pump, Discharge Check Valve and Expansion Joint

8. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 15 psig Test Temperature 83.5 deg F 05-0054

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: NMA Signed Ownned or On D& j~evs e . & Date 41l 7)510 Owner or Owner's Desge e CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of H-Artord, Connecticut, tjavp Ispected the components described In this Owners Report during the period of 7/'3/o q to 2/ flC5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                                  =c-C                 Z                   i         Commissions /,Z 1'74C/                     C-J Inspector's Signature                               Natonal Board, State, Providence, and Endorsements Date          ___         __        __

05-005-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Ught Co. Date 5/4/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Nam WO#: 32005681-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No, ete.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Naoe Authorization Number NWA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Component Cooling Water System #: 30 Quality Group C
5. (a)Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No CCW support N/A NA N/A 4-ACH-212 NA Installed N
7. Description of Work:

Replace corroded support with new support

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure N/A Other Vr-3 Pressure NIA psig Test Temperature NIA deg F 05-006-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Syrbol Stamp W/A Certificate of Authorization No. N/A Expiration Date: N/A Signed _ I 4; Date 5/Z./ as Owner or Owners Design . Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT 9f?Hrtford, Connecticut ave Inspcted the components described In this Owners Report during the period of ° to 6-5-OY and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owmers Report In accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceeming the examinations and oorrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. I'-/- '141: Commissions 'L 4'77('4?:C' Inspector s Signature National Board. State, Providence, and Endorsements Date _ _ _ _ _ _ _e _ _ _ 05-006-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 565/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34015515-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No, etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Nam Authorization Number N/A 9760 SW 344 Street Florida City. FL 33035 Address Expiration Date NWA
4. Identification of System: Component Cooling Water System #: 30 Quality Group C
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4A Component cooling water N/A N/A NIA 4E207A NWA Corrected heat exchanger
7. Description of Work:

Replace cap screw on channel head B. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure N/A Other NIA Pressure N/A psig Test Temperature NIA deg F 05-007-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: N/A Signs -' . 1 Date /I/ I Os Owner or Owner's Deslgnee,Tit~e CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of artVr, Connecticut, h Ins ed the components described In this Owners Report during the period of_ __ _ _0 _ to ?Zropel and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                         .d4Z 42                                                     Commisslons                        4,A __iCJ  C7 Inspectorei'Sgnature                                National Board. State. Providence, and Endorsements Date           21.1/t3" 05-007-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and LUght Co. Date 5/5/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34017659-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address RepairOrgarzation, P.O. No, Job No., etc
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NIA Name Authorization Number NWA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Intake Cooling Water System #: 19 Quality Group C
5. (a) Applicable Construction Code B31.1 1955 Edition, NZA Addenda, N/A -Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Check Valve for ICW 4A pump N/A D2886 N/A 4-50-311 NIA Installed N Check Valve N/A 00046590 NWA 4-60-311 N/A Removed N
7. Description of Work:

Replaced valve by bolting

8. Tests Conducted: Hydrostalic: NA Pneumatic NWA Nominal Operating Pressure NIA Other VT-2 Pressure 18 psig TestTemperature 75 deg F 05-008.4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A SigneI is1 5' Date X IV

                                                                                                                    "     0       _

Owneor Owneres Designee, Title D q CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have lnsspected the components described In this Owners Report during the period of /10/X-tO to _ _ _ _ _ _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. ___ Commissions r -77(4CL4, Inspectors Signature Natonal Board, State, Providence, and Endorsements Date _ _ _ _ _ _ 05-0084

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 5/512005 Namne 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 32020056-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No. Job No, etc.
3. Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp NMA Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Addrees Expiration Date N/A
4. Identification of System: Intake Cooflng Water System #: 19 Quality Group C
5. (a)Applicable Construction Code B31.1 19 55 Edition, NIA Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Basket strainer to ICW for NWA N/A NIA BS.4-1403 N/A Corrected N CCW heat exchangers
7. Description of Work:

Replace corroded cover studs

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure NIA Other NIA Pressure N/A psig Test Temperature N/A deg F 05-09-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. Type Code Symbol Stamp NWA Certificate of Authorization No. N/A Expiration Date: N/A Signed -__ 1 I1 . _, Date _5 S Owner or Owner's Designee, TM CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartfqrd, Connecticut, hav Inspected the components described In this Owners Report during the period of /Z 7-Cq to ) and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be glable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 144 v; a Commissions /2 17<Sa C. Inspector's Signature National Board, State. Prov6dence, and Endorsements Date 7A A< 05-009-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Ught Co. Date 5/5/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34021446-01 CR#: NtA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organixation, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp N/A Name Authorization Number NWA 9760 SW 344 Street Florida City, FL 33035 Expiration Date NIA Address
4. Identification of System: Intake Cooling Water System #: 19 Quality Group C
5. (a) Applicable Construction Code B31.1 1955 Edition. NIA Addenda, N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Butterfly Valve Between B and NfA 619828D N/A 4-50-350 NIA Installed N C CCW Heat Exchangers D-1-1 Butterfly Valve N/A F-61465 N/A 4-50-350 N/A Removed 8N
7. Description of Work:

Replace valve and bolting material

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other V`12 Pressure 20 pslg Test Temperature 84 deg F 05-010-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION; NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date: N/A Signed c 9_ SI7 u v' sa - Date 51)1J1 o f'--

                                            -vw-ul
                                                     -rrn uV --

e nrT h0l

                                                                          - Tt
                                                                            'cina
  • IU.

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartfrd, Connecticut. have Insepted the components described In this Owners Report during the period of_ -Z____ _ to 'a -O5 E and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Ovwners' Report In accordance with the requirements ofASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Impiled, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be Gable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. r4 'es Commissions /* 477 Ac C2 4 z

                       '        Inspectors Signature                                National Board. State, Providence, and Endorsements Date          8       ;ox 05-010-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 5/512005 Name 700 Universe Blvd. Juno Beach, FL- 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34021437-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organzatlion, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Lght Co. Type Code Symbol Stamp NWA Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NWA
4. Identification of System: Intake Cooling Water System #: 19 Quality Group C
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASIVE Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Butterfly valve, Basket Strainer N/A 619828D NIA 4-50-349 N/A Installed ICW Header B outlet D-3-1 _

Butterfly Vafve N/A 7.61465 N/A 4-50-349 N/A Removed N

7. Description of Work:

Replace valve and bolting material

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other VT-2 Pressure 20 psig Test Temperature 84 deg F 05-011-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: N/A Signed I 'S I  % %.ov

                                                                           ,, l       -
                                                                                         - il" deter       Date      5/, z to 5 Owner or Owners Designee, TIM8 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have inspected the components described In this Owners Report during the period of           4-60-of                to -B - 6Sr and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl.

By signing this Certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be gable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                      .s      4     24          c 4                                  Commissions S !41'7? (4,' C)

Inspectors Signature Natlonal Board, State. Providence, and Endorsements Date '/e/to< 05-01114

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Ught Co. Date 5/6/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34011470-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address RepairOrganizatlon, P.O. No, Job No., *tc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Intake Cooling Water System #: 19 Quality Group C
5. (a) Applicable Construction Code B31.1 1955 Edition, NIA Addenda, N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serlal National Other Year Removed or Stamp Component Number Board Identification Built Installed YeslNo Butterfly Iso Valve between B WNA 610942D N/A 4-50-307 WiA Installed N and C ICW pumps D-1-1 N Buttefly Valve NIA No Tag NIA 4-50-307 NIA Removed N
7. Description 01 Work:

Replace Valve and bolting material

8. Tests Conducted: Hydrostatic: NtA Pneumatic N/A Nominal Operating Pressure X Other VT-2 Pressure 20 psig Test Temperature 84 deg F 05-012-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/AI Expiration Date: N/A Signed '!'? 1- t- Date 5/ z-,S-

                                            -Owner or owners Designee,    I mue CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of FlorIda and employed by HSBCT of Harprd, Connecticut, have Inspected the components described Inthis Owners Report during the period of          4- 0o)                to _     __ _          _    _o and state that to the best of my knowledge and belief. the Owner has performed examinations and taken corrective measures described In this Owners' Report Inaccordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                           ,     74          /                                       Commissions        AZ In           X4, C, Al X)

Inspector's Signature National Board, State. Providence, and Endorsements Date W o_ 05-012-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 5/7/2005 Nane 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 33021448-01 CR#: 03-3733 9760 SW 344 Street Florida City. FL 33035 Address Repair Organization. P.O. No, Job No.. etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: containment building System #: 61 Quality Group B
5. (a)Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xi tUtilized for Repairs or Replacements 1998 Edition. 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Penetration P-SA blind flange WA N/A WA P-65A N/A Corrected N
7. Description of Work:

Replace bolting on P-65A blind flange one bolt at a time

8. Tests Conducted: Hydrostatic: WNA Pneumatic N/A Nominal Operating Pressure N/A Other NMA Pressure N/A psig Test Temperature N/A deg F 05-0134

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI, Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: N/A SMo-d _---M i S I SL uLeJ &- Date _ Date 8&r 1'7/0:)5 dwner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a vand commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCTojHartford,_Fonnectlcut, have inspe~ed the components described Inthis Owners Report during the period of V-Zi-D to 8-1B e and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected vAth this Inspection. A / Commissions /: f 0g (44 C, A457 Inspectors Signature National Board. State, Providence. and Endorsemenis Date  ;?-/f- ox"' 05-0134

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 5/7/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point-Plant Unit 4 Name WO#: 34011650-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No. Job No, etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Safety Injection Accumulator _System #: 64 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda. N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No B Accumulator Relief Valve NIA N/A NIA RV4-1858B N/A Corrected N
7. Description of Work:

Replace inlet bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other NIA Pressure NWA psig Test Temperature N/A deg F 05-0144

Sheet 2 of 2 FORM NtS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authoriation No. NIA Expiration Date: N/A Signed 1 CM Date 5_1_1__l__5 Owner or Owner's Designee, Tifle CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspcted the components described In this Owners Report during the period of 4-3"t'- . to 8-6-os and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report inaccordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                      -7   s;4           4                                           Commissions fA4i'77L(4C,4 A}7)

Inspector's Signature National Board. State, Providence. and Endosements Date S-4 -0C 05-014-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 517/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34003100-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No. Job No., etc.
3. Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Expiration Date N/A
4. Identification of System: Component Cooling Water System #: 30 Quality Group C
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Relief Valve to CCW surge tank NA D00828- N/A RV-4-707 N/A Corrected N 0001 _
7. Description of Work:

Replace Inlet flange bolting

8. Tests Conducted: Hydrostatc: N/A Pneumatic N/A Nominal Operating Pressure NIA Other N/A Pressure N/A psig Test Temperature N/A deg F 05-015-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: N/A Signed c 1-6 Date -5/ 12-/I 25 Owner or Owner's nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut. have inspected the components described Inthis Owners Report during the period of 5 ax to f - v- _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described Inthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

                    ,,_                      _           _       _                   Commissions /FZ 477 (4. CAI2)

Inspector's Signature National Board, State. Providence. and Endorsements Date 7i-{- OV~ 05-015-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 5/7/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34002347-IA CR#: N/A 9760 SW 3.44 Street Florida City, FL 33035 Address Repair Organization. P.O. No, Job No.. etc.
3. Work Performed by Florida Pover and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Steam Generators System #: 71 Quality Group B
5. (a) Appflcable Construction Code B31.1 1955 Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected. Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No "B' Steam Generator N/A N/A NWA 4E2l0B N/A corrected N
7. Description of Work:

Replace Bolt #5 on 1B1hand hole of 'B' Steam Generator

8. Tests Conducted: Hydrostatic: NWA Pneumatic NA Nominal Operating Pressure NWA Other NIA Pressure NIA psig Test Temperature N/A deg F 05-016-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signe ILS Is- I o  ; Date 51.J)OS5 Owner or Ownefs Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford Connecticut, have Inspected the components described In this Owners Report during the period of 4-Z - OS to F-Zz -oxS and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or lmpiled, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions f4 4t77 (4. Ci AJ. x) Inspector's Signature National Board. State. Providence, and Endorsements Date 05-016-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 5172005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 33021688-01 CR#: NMA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No, etc.
3. Work Performed by Florida Power and ight Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Main Steam System #: 72 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 EditIon, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, 1N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam 'C"Supply Valve N/A NIA N/A 4-10-319 N/A Corrected N to AFW Pumps
7. Description of Work:

Replace bonnet bolting

8. Tests Conducted: Hydrostatic: NA Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure tY/A psig Test Temperature N/A deg F 05-0174

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date: N/A Signed _ I Date 5: IrIl1 C Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have InspVted the components described In this Owners Report during the period of 4-z3 -er to i_-__ _ _ _ _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                       ,-     4             -                                         Commissions       n 47? 4 C, g/js)

Inspectors SIgnature National Board. State. Providence, and Endorsements Date F-6 05017-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Ught Co. Date 5f712005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34006575-02 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address tepairOrgantzatlon, P.O. No, Job No., OtC.
3. Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp NIA Name Authorization Numt ser NWA 9760 SW 344 Street Florida City, FL 33035 N/A Address Expiration Date
4. Identification of System: Emergency Diesel Engine and Oil System #: 22 Quality Group C S. (a)Applicable Construction Code B31.1 1955 Edition. N/A Addenda, N/A Code Case (b)Applicable EditIon of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4B Air Receiver Tank N/A N/A NIA 4T271 B NIA Corrected N
7. Description of Work:

Replace piping by welding

8. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure X Other VT-2 Pressure 200 psig Test Temperature 103 deg F 05-018-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. NfA Expiration Date: NIA SlgnedC I1 5 Owner or Owners Designee, Title etC Date 5// VI 0v CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCg of Hartfod. Connecticut, have inspectp*the components described in this Owners Report during the period of y to 2 -/49- 4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken correctIve measures described in this Owners' Report In accordance with the requirements of ASME Code. Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                         , A t                                                        Commissions            Z -47(4, C,,Al Inspector's Signature                               Nalional Board, State, Providence, and Endorsements Date             8'/5-<

05-018-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 517/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 32004932-1DI CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address RepaIr Orgaization, P.O. No, Job No., etc.
3. Work Performed b)F Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number NIA 9760 SW 344 Street Florida City. FL 33035 Expiration Date N/A Address
4. IdentifIcation of System: Intake Cooling Water System #: 19 Ouality Group C
5. (a)Applicable Construction Code B31.1 1955 Edition, NIA Addenda, NIA Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4B Intake Cooling Water Pump N/A IST-5 N/A 4P9B NIA Installed N Pump NIA IST-4 N/A 4P9B N/A Removed N Check Valve N/A D2664 NIA 4-50-321 N/A Installed N Check Valve NA None N/A 4-50-321 N/A Removed N
7. Description of Work:

Replace Pump, discharge check valve, expansion joint and discharge elbow

8. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure X Other VT-2 Pressure 20 psig Test Temperature 90 deg F 05-019-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks CERTIFICATE OF COMPLIANCE Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: N/A Sign Date l / 7Z/S Owner or Owner s Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartfgrd, Connecticut, have Inspested the components described i this Owners Report during the period of ______ _ to $-

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report Inaccordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. X-47 e> _ Commissions AS 477(4,C, Al,) Inspector's Signature National Board. State, Providence, and Endorsements Date _S -e I 05-019-4

FORM NIS-2 OWNERS REPORT FOR REPAiRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 5/9/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 31020696-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address uepair Organization, P.O. NO, Job No, Wtc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NMA Name Authorization Numt ,er N/A 9760 SW 344 Street Florida City, FL 33035 Expiration Date N/A Address
4. Identification of System: Residual Heat Removal System #, 50 Quality Group B
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Conected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Inlet Valve to RHR Pump B N/A NA N/A 4-752B N/A Corrected N
7. Description of Work:

Rplace Body to Bonnet Bolting S. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature NWA deg F 05-020-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: NIA Signed _ ' O Si Date __2s _ Owner or Owner's ;Designee, TitelII CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspeted the components described In this Owners Report during the period of /-1-rO 3 to e-I-ras and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damnage or a loss of any kind arising from or connected with this Inspection.

                          ,-<   vi            B        u                              Commissions       /     4?? (A, CAl,          z)

Inspector's Signature National Board, State, Providence. end Endorsements Date ___ _____ 05-020-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date S1912005 Narne 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 35007926-01 CR#: 0510946 9760 SW 344 Street Florida City, FL 33035 Address -- Repair Organization, P.O. No. Job No, etc.
3. Work Performed by Florida Power and Liaht Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: CVCS Charging and Letdown System #: 47 Quality Group A
5. (a)Applicable Construction Code B31.1 19 55 Edition. N/A Addenda, NA Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Charging to Reactor Coolant NIA N/A NIA CV-4.310B NIA Corrected Loop C Control Valve N
7. Description of Work:

Replace Body to Bonnet Bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic NWA Nominal Operating Pressure N/A Other VT-1 Pressure NWA psig Test Temperature N/A deg F 05-021-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed IS_I S - Date ____/ ___ Owner or Owner's Designee. Title V CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a vaid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT 9f Hartford. Connecticut, have Insted the components described In this Owners Report during the period of  ?..O* to 5F4-a and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the examinations and corrective measures described Inthis Owners! Report. Furthermore, neither the Inspector nor his employer shall be liable hIany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions i4 477(4; C, <v r) Inspector's Signature National Board, State. Providence, and Endorsements Date r-e-05-021-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.Owner Florida Power and Light Co. Date 5/10/2005 Narne 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address Turkey Point Plant Unit 4

2. Plant Name WO#: 34011721-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No*, etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. identification of System: Residual Heat Removal System #: 50 Quality Group B
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A CodeCase (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, NWA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Isolation Valve for RHR Pump NIA N/A N/A 4-754A N/A Corrected A Discharge N
7. Desaciption of Work:

Replace Body to Bonnet Bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure NIA Other N/A Pressure N/A psig Test Temperature N/A deg F 05-022-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: NMA Signed I S I 5 u'o c!ver BesotC' 3 Date A Ownor Owner's Designee. Title' CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut. have inspected the components described In this Owners Report during the period of _Z- mZto ____to and state that to the best of my knowledge and bellef, the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described Inthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. a-:r;'- -Commisslons _-1:~~244 , 77(4c ,v ) Inspectors Signature Natonal Board. State. Providence, and Endorsements Date S-6 Cog 05-022-4

FORM NIS.2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 5/11/2005 Narne 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WON: 34003107-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair OrganizaUon, P.O. No, Job No, etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number NWA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Component Cooling Water System #: 30 Quality Group C
5. (a)Applicable Construction Code B31.1 1955 Edition, N/A Addenda. NIA Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Relief Valve for CCW ECC B N/A TH18078 N/A RV-4-1423 N/A Installed N Relief Valve N/A TH 18072 N/A RV-4-1423 NIA Removed N
7. Description of Work:

Replace Relief Valve with spare

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure X Other VT-2 Pressure 122 psig Test Temperature 70 deg F 05-023-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLiANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp INA Certificate of Authorization No. NIA Expiration Date: NIA Sign_ = _ Date 5 _I ) C, Owner or Owner's Designee, t'ie CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut. have Inspected the components described In this OwnersReportduringtheperiodof 3-.4* - j.oa to S i7-AoO r and state that to the best of my knowledge and berlef, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. CommssslonsA ons/ZAX 4 9f2La sctors Signature National Board, State, Providence, and Endorsements Date .g- /7.2oo 05-0234

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Ught Co. Date 5111/2005 Name 700 tJniverse Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34003135-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No, Job No., etc.
3. Work Performed by Florida Power and Lioht Co. Type Code Symbol Stamp NUA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Component Cooling Water System #: 30 Quality Group C
5. (a) Applicable Construction Code B31.1 1955 Edition, NIA Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Relief Valve for CCW to ECC C N/A TH1085 N/A RV-4-1424 N/A Installed N Relief Valve NWA TH18089 NIA RV-4-1424 N/A Removed N
7. Description of Work:

Replace Relief Valve with spare

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating IPressure X Other VT-2 Pressure 121 psig Test Temperature 70 deg F 05-024-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date: NIA Signede - SWI X Pg  ; soiw Date 5) I5D) C,_ Owner or Owner's Designee, ?itle CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspected the components described In this Owners Report during the period of 3- IS2- 2t ot C to .- ' /7 - .2oo S and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report inaccordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions JO-A,nd. F. A18 - Ins or's Signature National Board, State. Providence. and Endorsements Date S-/7-;2ooS 05-024-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 5/1112005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Namne WO#: 34003140-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No;. etc.
3. Work Performed by Florida Power and Llaht Co. Type Code Symbol Stamp N/A Narne Authorization Number NIA 9760 SW 344 Street Florida Clty, FL 33035 Expiration Date NIA Address
4. Identification of System: Component Cooling Water System #: 330 Quality Group C
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Relief Valve for CCW to ECC A N/A TH 18076 N/A RV-4-1425 NIA Installed N Relief Valve NIA TH18077 N/A RV-4-1425 NIA Removed N
7. Description of Work:

Replace Rerief Valve with spare

8. Tests Conducted: Hydrostatic: NIA Pneumatic NIA Nominal Operating Pressure X Other VT-2 Pressure 122 psig TestTemperature 70 deg F 05-025-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp NWA Certificate of Authorization No. N/A Expiration Date: NIA Sign _ I_= 1-N V ksv - Date_.;l{ ol>5 Ovnror Owner's Designee Ie CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford. Connecticut, have Inspected the components described In this Owners Report during the period of .!t-A4 - ZooS to 6 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners! Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. (ommMICOAr AIA '9Qo A A, r Fat -iR I dor's Signature Natonal Board, State, Providence. and Endorsements Date 5J1,Zo a 05-0254

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 5/1012005 Nane 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 31020697.01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address epair Organlizatlon, P.O. No, Job No.. etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Numb er NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Residual Heat Removal _System #: 50 Quality Group B
5. (a) Applicable Construction Code B31.1 1955 EdItion, N/A Addenda, N/A Code Case (b) Appilcable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serlal National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Inlet Valve to RHR Pump A N/A N/A N 4-752A WA Corrected N
7. Description of Work:

Replace Body to Bonnet Bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure NIA Other N/A Pressure N/A psig Test Temperature N/A deg F 05-026-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTiFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp NIA Certificate of Authorization No. WJA IExpiration Date: NIA Signed _ -hi SI _'R IXJt.5¢ . J.: wei, Date  ;/ ao5 Owner or Owneds DesIgnee,1Titre CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Insp ad the components described In this Owners Report during the period of OS-8-a5 to '-6 -o and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

                    ,  AC4                            If                                Commissions Em          77 A         (y C.,

Inspectoes Signature National Board, State. Providence, and Endorsements Date St-_6_- or 05-0264

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi 1.Owner Florida Power and Ught Co. Date 31312005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address

2. Plant Turkey Point Plant Unit 4 Nate WO#: 3400119641 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repir Organization, P.O. No. Job No.. etc.
3. Work Performed by - Florida Power and Llaht Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Addzess Expiration Date NWA
4. Identification of System: Intake Cooling Water System #: 19 Quality Group C
5. (a)Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Inlet Butterfly valve to A ICW N/A 61 9828D N/A 4-50-324 N/A Installed Basket strainer D-3-3 N Buttefly Valve N/A No Tag NIA 4-50-324 N/A Removed N
7. Description of Work:

Replace Valve and bolting

8. Tests Conducted: Hydrostatic N/A Pneumatic _ NIA Nominal Operating Pressure X Other VT-2 Pressure 22 psig Test Temperature 78 deg F 054027-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: N/A Signed W fS Date eR11,010o O or Owners signee TI CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT o Hartford, Connecticut, have ipspectd the components described In this COwners Report during the period or . to G/..os I// and state that to the best of my knowledge and belef, the Owner has performed examinations and taken corrective measures described In this Owners/ Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Iniplied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                        ,              <                                             Commissions                    (,C,AJ   A/77.2')

Inspectors Signature National Board, State, Providence, and Endorsements Date _ /_ __ _ _ 05-027-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 5111/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34011469-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No., ett.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp WA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expirallon Date N/A
4. Identification of System: Intake Cooling Water System #: 19 Quality Group C
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, - N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identificatfori of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Butterfly Isolation Valve N/A 646626D N/A 4-50-309 NIA Installed N between A and B ICW pumps D-1-1N Butterfly Valve N/A No Tag NIA 4-50-309 N/A Removed N
7. Description of Work:

Replace Valve and bolting material 8, Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other VT-2 Pressure 22 psig Test Temperature 78 deg F 05-028-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certlfy that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: NIA Signed I I V Ov- Date 5__ l _ 0 s Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspectd-the components described in this Owners Report during the period of 4- B -o* to E' 0-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance vwth the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 64; / Commissions >i 4n?(s. v Inspectors Signature National Board, State, Providence, and Endorsements Date e-0"028.4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Flohida Power and Light Co. Date 5/111/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34021438-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NIA Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Intake Cooling Water System *-. 19 Quality Group C
5. (a)Applicable Construction Code B31.1 19 55 Edition, NIA Addenda, N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected. Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Outlet Butterfly vaive from ICW N/A 619828D N/A 4-50-329 N/A InstalledN basket strainer D-3-2 N Butterfly Valve NIA RGP1556 N/A 4-50-329 N/A Removed N
7. Description of Work:

Replace valve and bolting material

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure X Other . VT-2 Pressure 22 psig Test Temperature 78 deg F 05-029-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA NExpiration Date: NIA Signed IS? Z or -Date S/LP/D5-Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspected the components described In this OwnersReportduringtheperiodof 4-,-^2o5 to S-J6- Loos and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions A/ JoAgir FL a29 ector's Signature National Board, State. Providence, and Endorsements Date 6p-4J-;Z0*°. 05-029-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 51113/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address
2. Plant Turkey Point Plant Unit 4 Namre WO#: 34003027- 01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair organlzatlon, PO. No, Job No, ete.
3. Work Performecd b!V. Florida Power and Light Co. Type Code Symbol Stamp NIA Name Authortzation Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Supports and Hangers System #: 1C 15 Quality Group A
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 EditIon, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components K Corrected, ASME Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Snubber PSA 11923 N 4-1039 N/A Removed N Snubber PSA 42872 N 4-1039 N/A Installed N Snubber Load Pin PSA 17177 N 4-1014 NIA Corrected N
7. Description of Work:

Replace Snubber 4-1039 and replace load pin on snubber 4-1014

8. Tests Conducted: Hydrostatc N/A Pneumatic NIA Nominal Operating Pressure N/A Other VT-3 Pressure N/A psig Test Temperature N/A deg F 05-030-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp MNA Certificate of Authorization No. N/A Expiration Date: N/A Signed IeS.gneeT.i I Date l IL1 0vs Owner or Owner's lesignee,Title\ CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspected the components described In this Owners Report during the period of 104-6-os to f-O1 -o5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report Inaccordance With the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                                        "I/,,                                        Commissions Ah           1{46          C 4v -zi Inspector's Signature                               National Board, State. Providence. and Endorsements Date             8- 0P_ 0 05.0304

FORM NIS.2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 5/112/2005 Name 700 Universe Blvd. Juno Beach. FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 33017656-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No, Job No.. etc.
3. Work Performed by Fiorlda Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Residual Heat Removal System #: 50 Quality Group B
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Cede Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Residual Heat Rmoval Pump NIA N/A NIA RO4-1468 N/A Corrected Recirc Line Restricting OiceN
7. Description of Work:

Replace Flange Bolting

8. Tests Conducted: Hydrostatic N/A Pneumatic NIA Nominal Operating Pressure NIA Other N/A Pressure N/A psig Test Temperature N/A deg F 05-031-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: N/A Signed _ JIS1 __ Date 5I/ IL/J Owner or Ow'ners Designee, Title DaI CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspecteghe components described In this Owners Report during the period of -tr-'hV to _ 6-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neitherthe Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 Commissions F/r; 47.77 (mC' A, 27) Inspectores Signature Natonal Board, State. Providence, rnd Endorsement Date 05-031-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 51116/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address
2. Plant Turkey Point Plant Unit 4 Nome WO#: 33017571- 01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No. etc.

f

3. Work Performe 1bj Florida Power and Light Co. Type Code Symbol Stamp NIA Name Authorization Number NIA 9760 SW 344 Street Florida City. FL 33035 Address Expiration Date NIA
4. Identification of System: CVCS Charging and Letdown System #: 417 Ouality Group B
5. (a)Applicable Construction Code B31.1 19 55 EditIon. NIA Addenda, NIA Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition. 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No RWST to Charging pump N/A NIA N/A 4-357 N/A Corrected Suction Check Valve N
7. Description of Work:

Replace body to bonnet bolting

8. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature N/A deg F 05-032-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date: N/A Signed___ _ _ ___ Date _5ji b< Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspected the components described Inthis Owners Report during the period of 3 OS to _5__ _ _ _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 Z1 011 '4 Commissions 6.:477 ( >;I} Inspector's Signature National Board, State, Providence, end Endorsements Date _ _ _-_-_ 05-032-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 6/16/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address Turkey Point Plant Unit 4
2. Plant Name WO#: 35000367-01 CRt# NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No, Job No, etc.
3. Work Performed by Florida Power and LUght Co. Type Code Symbol Stamp NfA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date . NIA
4. Identiflcation of System: CVCS Charging and Letdown System #: 47 Quality Group A
5. (a)Applicable Construction Code B31.1 19 55 Edition, NIA Addenda, NIA Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Relief Valve for Regen Heat N/A NIA NA RVW4-31 I NA Removed N ExchangerN Restricting Orifice NIA N/A N/A RO-4-311 N/A Installed N
7. Description of Work:

Remove valve, cap line and add bypass rine and RO-4-311 per PCM 04-056

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure NWA Other N/A Pressure N/A psig Test Temperature N/A deg F 05-033-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks CERTIFICATE OF COMPUANCE Type Code Symbol Stamp N/A Certificate of Authorization No. N/A IExpiration Date: N/A Signed _ I S I -S pV-. Date _8_ __ C>

Owner or Owners Designee, Title CERTIFiCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of HartfoglConnectlcut, have inspecW the components described In this Owners Report during the period of , f-O- to 5-/7- OX, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. c Sn Commissions tA -z CA c, C 7

                         .1' Inspector s Signature                                National Board, Slate, Providence, and Endorsements Date          II/7-oJl 05-033-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 5/23/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 WO#: 34011774-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No.. etc.
3. Work Performed byF Florida Power and ght Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Safety Injection System #: 62 Quality Group B
5. (a)Applicable Construction Code B31.1 1955 Edition, NIA Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Si Boundary Isolation Valve N/A N/A N/A 4-867 N/A Corrected N
7. Description of Work:

Replace bonnet bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other NWA Pressure N/A psig Test Temperature N/A deg F 05-034-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. NWA Expiration Date: N/A Signe Ft1r Date _ / Owner or Owners Design , Title CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding avalid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have inspected the components described In this Owners Report during the period of 4-7-OS to g-5-05 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. 6 / Commissions ___7__C, __1) Inspector's Signature National Board, State, Providence, and Endorsements Date 05-034-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 4/25/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34009352-02 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Kepair Orgarbzation, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Main Feedwater System #: 74 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Feedwater Flow control N/A N/A N/A FCV4-478 N/A Corrected N valveN
7. Description of Work:

Internal weld buildup for new marhined/threaded In seaL

8. Tests Conducted: Hydrostatic: NWA Pneumatic NWA Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature N/A deg F 05-035-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: NIA Si1ge SolT Date 6)J 1-7 /1o Owner or Owners Designee, Tie CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford. Connecticut, have Inspected the components described In this Owners Report during the period of 4-z-oom to I'-/ 8 and state that to the best of my knowiiedge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _ Commissions ,i477 6(i c,1,Z1 Inspector's Signature National Board, State, Providence, and Endorseents Date g-r s-OS 05-0354

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Omner Florida Power and Light Co. Date 6/20/2005 name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34022782-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair OrganzaUoto, P.O. No, Job No.. etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Main Steam System #: 72 Quality Group B
5. (a)Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition. - 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam Safety Valve NfA BY-96920 NIA RV-4-1402 N/A Installed N Valve N/A BL0405 N/A RV-4-1402 N/A Removed N
7. Description of Work:

Replace Valve

8. Tests Conducted: Hydrostatic NWA Pneumatic NIA Nominal Operating Pressure x Other NIA Pressure 996 psig Test Temperature 287.7 deg F 05-036-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp NIA Certificate of Authorization No. NIlA Expiration Date: N/A Sbnedat I StI vCCv 58 -_ Date 6/_4 _705-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT pf Hartfo, Connecticut. have inspect the components described in this Owners Report during the period of ____ _ _ ____ to l- Zo - o - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owners! Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

                        ,t;         6      <?    iCommissions                                            At- 41?7 (4, Ci A 2J Inspectores Signature                              National Board, State. Providence, and Endorsements Date   __     ___-_

05036-4

FORM NIS.2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owener Florida Power and Light Co. Date 6/22/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 32014491-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No., *et
3. Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NWA
4. identificatIon of System, Main Feedwater System #: 74 Quality Group B
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected. Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed YeslNo Feedwater Checkvalve NIA NIA NIA CV-4-2900 N/A Corrected N
7. Description of Work:

Replace bolt during overhaul

8. Tests Conducted: Hydrostatic: NIA Pneumatic NIA Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature N/A deg F 05-037-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: N/A Signed ^ iZ I RSI Date J1;L Al OS Owner or Owneres Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspeded the components described in this Owners Report during the period of 5 Ztoe' X* to _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners! Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                          -4       4                          /                      Commissions y Inspector's Signature                              National Board, State, Providence, and Endorsements Date   __              _7-_ _-_

05.037-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl 1.Owner Florida Power and Ught Co. Date 61t20/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 _ of 2 Address

2. Plant Turkey Point Plant Unit 4 Name WO#: 34001760- 01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization P.O. No Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Intake Cooling Water System #: 119 Quality Group C
5. (a) Applicable Construction Code B31.1 19 55 Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected. Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No TPCW Heat Exchanger N/A 619828D N/A POV-4-4882 N/A Installed Isolation Valve D-2-1 N Valve N/A 7.63359-3 N/A POV4-4882 N/A Removed N
7. Description of Work:

Replace valve and bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 14 psig TestTemperature 90 deg F 05-038-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. NWA Expiration D.ate: NIA Slgned  : . - - 3.z- 0,.-. - -- -- - Date 6/ _7/05_ Owner or Omer's Designee, ilUe CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of HartfordConnecticut, have Inspeted the components described In this Owners Report during the period of _ -_ _ _ to F-.S 0 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report Inaccordance with the requirements of ASME Code, SectIon XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be lable In any manner for any personal Injury or property damage or a loss of any kind arisIng from or connected with this inspection.

                               #4        <<4             4                              co Commissions        2 774 C44J National Board, State. Providence, and Endorsements Inspector's Signature Date 05-038-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 6/20/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34004423-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035
                                            . Address                                                           Repair Organizatlon, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Intake Cooling Water _System #: 19 Quality Group C
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 98 Edition. 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No TPCW Heat Exchanger N/A 613828- NIA POV-44883 N/A Installed Isolation valve DD-2-2 N Valve N/A 7-63359-3 N/A POV-44883 NIA Removed N
7. Description of Work:

Replace Valve and bolting per PCM04-299

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 14 psig Test Temperature 90 deg F 05-039-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp NfA Certificate of Authorization No. NIA Expiration D;ate: NIA Signed is~lSi V%.,S Y - Date 6I;L 8/Dp Owner or owners Designee, Tite CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut. have Inspected the components described in this Owners Report during the period of 2-2Z- o5 to 'i-5-05 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _c ,- A Commissions }i 4774, C, AlJC :c Inspectors Signature National Board, State, Providence, and Endorsements Date 05-039-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date - 6120/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 35007801-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organlzaflon, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Llaht Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Main Steam System #: 72 Quality Group B
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam Safety Valve N/A BY96919 N/A RV4-1411 N/A Installed N Valve NIA BL0404 N/A RV-4-1411 N/A Removed N
7. Description of Work:

Replace Valve

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure X Other N/A Pressure 996 psig TestTemperature 287.7 deg F 05-040-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. Type Code Symbol Stamp NMA Certificate of Authorization No. N/A Expiration Date: N/A Signed I MI 8.

                                                                        & Li
  • _t_,

v L% r- Date i / Lal05 Owner or Owner's Designee, Tifle I CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCTpf Hartfor. Connecticut, have Inspect ehe components described Inthis Owners Report during the period of .21-O to . R-. .Z ^° v .. and state that to the best of my knowledge and benlef, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code. Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 - -Commissions fi- 177(4z 4. 17 Inspector's Signature Natonal Board, State. Providence, and Endorseffents Date 05-040-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 6/2112005 Narne 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34000320-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organtzatlon, P.O. No, Job No.. etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp WA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Main Steam System #: 72 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, NIA Code Case (b)Appflcable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam Isolation Bypass NIA NIA NIA MOV-4-1400 N/A Corrected N ValveN
7. Description of Work:

Replace valve bonnet and bonnet bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure X Other N/A Pressure I996 psig Test Temperature 287.7 deg F 05-041-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: N/A Signed 3 4Si 3prV0 _S6xr Date SI l1 /X ' Owner 6r Ovwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartfor, Connecticut, have inspected the components described In this Owners Report during the period of 4-%f to ?Of 9-0.S' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report in accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. e

  • Commissions L' (e-4 C, 4C,2 Inspector's Signature National Board, State, Providence, and Endorsements Date W-Z8-or 05-041-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl 1.Owner Florida Power and Light Co. Date 6/21/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address

2. Plant Turkey Point Plant Unit 4 Name WO#: 31019878-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Orgadzationt, P.O. No, Job No. etc.
3. Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Main Steam System #: 72 Quality Group B
5. (a)Applicable Construction Code 831.1 19 55 Edition, N/A Addenda, NIA Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 199B Edition. 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam Isolation Valve N/A NIA MA POV.4-2604 NIA Corrected N
7. Description of Work:

Replace bolting on rockshaft cover

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure N/A psig Test Temperature N/A deg F 05-042-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code. Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed - A ) eAdv * & i Date 6 C Owner or Owneres Designee, TFle\I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding avalid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Ha2o Connecticut. have inpected the components described In this Owners Report during the period of 5 to 8&5. On and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code. Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. A _ Commissions AZ 47,7 C, W, Inspectors Signature National Board. State, Providence, and Endorsements Date _ -sOr' 05-042-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 6/21/2005 Nams 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO# 34015793-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No. et
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: CVCS Charging and Letdown System #: 47 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 Edition, NIA Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Seal Water Injection Filter NWA N/A N/A 4-293A N/A Installed N Outlet valve N
  • 7. Description of Work:
Replace valve by welding
8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other NIA Pressure 2460 psig Test Temperature 102 deg F 05-043-4

Sheet 2 of 2 FORM NIS-2 (Back) 9- Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp XIA Certificate of Authorization No. WA Expiration Date: NIA Signed if i Date 6} . a Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspected the components described Inthis Owners Report during the period of 7-i -ox- to -_ ___ ___ and state that to the best of my knowledge and beflef, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code. Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                                         -                   ?                         Commissions a 477 (A, S JI Inspectors Signature                                 Natonal Board, Stale. Providence, and Endorsements Date     g9O4. o<

05-043-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 6/21/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34015794-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Expiration Date N/A Address
4. Identification of System: CVCS Charging and Letdown System #: 47 Quality Group B
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Seal water filter 'B inlet N/A NIA N/A 4-293B N/A Installed -

Isolation vahe N

7. Description of Work:

Replace valve by welding

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 2460 psig Test Temperature 102 deg F 05-044-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: NIA Signed 1'I _s___ Date 62sVb 17- ? 1&. Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspectethe components described In this Owners Report during the period of V'-1..O to Sdm-os and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Impfled. concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 ,v4 -- a-?$ Commissions 4Z7(4 4CC, sc) Inspector's Signature National Board, State. Providence. and Endorsernen6 Date F- z ta-05-044-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi 1.Owner Florida Power and Light Co. Date 6/2212005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address

2. Plant Turkey Point Plant Unit 4 Name WOU: 35012655-02 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No, Job No., etc.
3. Work Performed by Florida Power and Llaht Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Component Cooling Water System #: 30 Quality Group B
5. (a) Applicable Construction Code B31 .1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 98 Edition. 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Control Valve for CCW to ECC N/AN4A N/ACV-2908 N/A Corrected N
7. Description of Work:

Replace bolting material during overhaul

8. Tests Conducted: Hydrostatic: N/A Pneumatic NWA Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature N/A deg F 05-045-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A AExpiration Date: NIA Signed I&I .xS nA d Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hart!.rd, Connecticut, have Inspecgd the components described In this Owners Report during the period of 5,30-CS to 3 -137 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. __ __ _Commissions '- ;Pv Af, 7)- Inspector's Signature Natlonal Board, State, Providence, and Endorsements Date _ OQ-°t 05-045-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 6)22r2O05 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address Turkey Point Plant Unit 4
2. Plant Name WO#: 34011623-02 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Nane Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: CVCS Charging and Letdown _System #: 47 Quality Group B
5. (a)Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, NIA Code Case S. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Letdown Relief Valve N/A N/A N/A RV-4-203 N/A Corrected N
7. Description of Work:

Reroute Inlet piping by welding

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other NIA Pressure 275 psig Test Temperature 120 deg F 05-0464

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed D s-eIIIse 12%cieV Date 8/ l O6s Owner or Owner's Designee, TitleI I CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford Connecticut, have Inspected the components described In this Owners Report during the period of l? or to 7- 20o-and state that to the best of my knowledge and belieft. the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code. Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _ _ _ _ _ _ _ Commissions 4 4777 4,C,' ya,) Inspector's Signature National Board, State. Providence, and Endorsements Date -- a - 05-0464

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 71612005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34000319-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organlzatiort, P.O. No, Job No., etc.
3. Work Performed b)I Florida Power and Liaht Co. Type Code Symbol Stamp N/A Name Authorization Number NIA 9760 SW 344 Street Florida City. FL 33035 Address Expiration Date N/A
4. IdentificatIon of System: Main Steam System #: 72 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 Edition, WNA Addenda, N/A Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. IdentIfication of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam Ulne B' Isolation N/A N/A N/A MOV-4-1401 N/A Corrected bypass valve N
7. Description of Woric Replace valve bonnet and bonnet bolting
8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 996 psIg Test Temperature 287.7 deg F 05-047-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code. Section Xi. Type Code Symbol Stamp NIA Certificate of Authorization No. NMA Expiration Date: NJA Signed ISi Date - 1/7/1a5 ner or Owners Designee, Trie CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have inspei the components described In this Owners Report during the period of 9 05 to g-/f .. i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. ________ commissions A Inspector's Signature National Board, State. Providence, and Endorsements Date __ ___ ___ 05-047-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

  • As Required by the Provisions of the ASME Code Section Xl
1. Owner Florida Power and Light Co. Date 6123/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address Turkey Point Plant Unit 4
2. Plant Name WO#: 35012782-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address RepaWr OrganLzatin. P.O. No, Job No, etc.

3.Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp N/A Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 NIA Address Expiration Date

4. Identification of System: Component Cooling Water System t. 30 Quality Group C
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No CCW Pump;A Discharge N/A N/A NIA 4-702A NIA Corrected N Check ValveN
7. Description of Work:

Replace bolting

8. Tests Conducted. Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure NIA psig Test Temperature N/A deg F 05-048-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration D.)te: NIA Signed ,1&1 Date 6 rO i s Owr0er or Owner's Designee, title ' CERTiFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut. have Inspe5ed the components described Inthis Owners Report during the period of 5g-- o: to A4 0 w and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners! Report Inaccordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _ 4 Commissions AZ '177 (4 ,C , ,T) Inspector's Signature National Board, State, Providence, and Endorsements Date __ _ _ _ _ _ 05-0484

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 6/23/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address Turkey Point Plant Unit 4
2. Plant Name WOM; 35003504-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp NMA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Reactor Coolant System #: 41 Quarity Group A
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Pressurizer PORV N/A N/A N/A PCV-4455C N/A Corrected N
7. Description of Work.

Replace one Nut

8. Tests Conducted: Hydrostatic, N/A Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure N/A psig TestTemperature N/A deg F 05-049-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: NI/A Signed 5 Ai tscptSe~r Date X _____8 _ Owner or Owner's Designee, Tile CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspecpd the components described in this Owners Report during the period of 5-/-OSr to Y a and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 1d s 1 Commisslons /. 4 Ao 2 Inspector's Signature Natlonal Board, State. Providence, and Endorsements Date A-__ __ _ _ 05-049-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 6/223/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WOX: 34001672-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No, etc.
3. Work Performei I by Florida Power and Liaht Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City. FL 33035 Address Expiration Date N/A
4. Identification of System: Reactor Vessel System #: 443 Quality Group A
5. (a)Applicable Construction Code B31.1 19 55 Edition, NIA Addenda. N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected. Code Nameof Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Reactor Vent Orifice N/A N/A NIA RO-4-6316 N/A Corrected N
7. Description of Work:

Replace bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic WA Nominal Operating Pressure NIA Other NIA Pressure NIA psig Test Temperature N/A deg F 05 050A4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code. Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: NIA Signed emv; A for Date 7- 81) o 5 Owner or Owner's Designee Ote CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding avalid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, gonnecticut have Insp ted the components described In this Owners Report during the period of O-s to _ 4-O__ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any Warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

                                   /,4           t~                                  Commissions               f          7          2)

Inspector's Signature National Board, State. Providence, and Endorserents Date  ?-.d o < 05-050-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 6/2312005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet i of 2 Address
2. Plant -

Turkev

                                      . _ _,Point. Plant

_ _ Unit 4 Name WO#: 35010877-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address RepairOrgarizstorn. P.O. No, Job No., etc.

3. Work Performei Ibyr Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Safety Injection System #: 662 Quality Group A
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda. N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda. N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No SI to Loop A drain valve N/A N/A N/A 4-873D N/A Installed N 7.Descripuon of VVorK:

Replace valve by Swagelock fittings

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature N/A deg F 05-0514

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp NIA Certificate of Authorization No. NWA Expiration Date: NIA Signed tis)s u l6 Date 6h-eio! Owner orbwner's Designee, itle CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford Connecticut. have Inspejted the components described In this Owners Report during the period of _ __ ___ to F--O' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _I,, __ Commissions i i 74C,? 4 ,AFJ Inspector's Signature National Board, State, Providence, and Endorsements Date F4 S 05-0514

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.Owner Florida Power and Light Co. Date 6123/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address

2. Plant Turkey Point Plant Unit 4 Name WO#: 33019901-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Llaht Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Expiration Date NIA Address
4. Identification of System: Main Steam -System M. 72 Quality Group B
5. (a) Applicable Construction Code 831.1 1955 Edition, NIA Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component . Number Board Identification Built Installed Yes/No Main Steam Dump to N/AN/A N/ACV4-1608 N/A Corrected Atmosphere Control Valve N
7. Description of Work:

Install new valve seat and seal weld

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure NIA Other N/A Pressure N/A psig Test Temperature N/A deg F 05-052-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp NWA Certificate of Authorization No. NZA -Expiration Date: NIA Signed IS-i dSu J te Date _ I 8/ oIn o;.¢ Ownier or Owner's Designee, Titre CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of BoDer and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have inspeded the components described In this Owners Report during the period of 4.-zz-oS to 7 -oS and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be gable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. __ _ __ _ __ _ _Commissions f 7.7 Inspector's Signature National Board, State, Providence, and Endorsem nts Date 7- Z4 05-052-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 6123/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 35010036-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No, etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Safety Injection System #: 62 Quality Group A
5. (a)Applicabie Construction Code B31.1 19 55 Edition, NIA Addenda, NIA Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mig Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No SI to Loop C Drain Valve WA N/A N/A 4-873F N/A Corrected N
7. Description of Work:

Replace swagelock connector by welding.

8. Tests Conducted: Hydrostatic: NIA Pneumatic NWA Nominal Operating Pressure NIA Other NIA Pressure N/A psig Test Temperature N/A deg F 05-053-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code. Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NWA Expiration Date: NIA

                                                             ' S1_     og~tU;&&                        Date         l I1     Itb-5 Signed Owner or Owner's Designee,'1itle CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspe +/-ed the components described Inthis Owners Report during the period of            A4-t4_e5             to   by-/ 0 -OS and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                                              ~ 6t~-~/f~-4                            Commissions           A 4??      i      C1
  • X Inspectors Signature National Board. State. Providence. and Endorsernents Date S-1eo5.

05-053-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 6/23/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 35007973-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O.No. Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number NWA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: CVCS Charging and Letdown System #M _ 17 Quality Group A
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected. Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No RCP Loop A Seal Pressure N/A N/A N/A 4-299B N/A Corrected Tap Isolation Valve N
7. Description of Work:

Replace Flange Bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure NIA Other NIA Pressure NIA psig TestTemperature N/A deg F 05-054-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A _ Expiration Date: NMA Signed

  • 1So 6 &n - Date 6l ;L I o Owner or Owner's Designee, a CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartfjrd, Connecticut, have Inspedq.the components described Inthis Owners Report during the period of__5_-______ to 7- - CS and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report Inaccordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Inplied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

                       ,                Y                                            Commissions              472 (Al C,,Z) 47e Inspectors Signature                                National Board, State. Providence, and Endorsements Date         7-74:        A<

05-054-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owrner Florida Power and Ught Co. Date 6/28/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 33019898-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organizaton. P.O. No, Job No. etc.
3. Work Performed by Florida Power and Ught Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City. FL 33035 Address Expiration Date N/A
4. Identification of System: Main Steam -System #: 72 Quality Group B
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda. NIA Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam B" Steam Dump N/A N/A NIA CV-4-1607 N/A Corrected to Atmosphere Valve N
7. Description of Work:

Weld build up on Internal valve body and seal weld new seat

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure NWA Other NWA Pressure N/A psig Test Temperature NIA deg F 05-055-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed e or O TSowreev or Date 81 I I/OS5 Owneror Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspgcted the components described Inthis Owners Report during the period of 4-Z-°O _ to _ -_ 7-_q_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of ASME Code, Section X1. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

                      ,I           -                                                 Commissions         ee 477(4&C, Inspector's Signature                               National Board. State, Provfdence, and Endorsements Date          Pow-         ° 05-055-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi 1.Owner Florida Power and Light Co. Date 6/29/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of . 2 Address

2. Plant Turkey Point Plant Unit 4 Naro. WO#: 34011651-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Ropalr Organizalton, P.O. No. Job No., etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Safety InJection Accumulator .System #: 64 Quality Group B
5. (a)Applicable Construction Code B31.1 1955 Edition, NWA Addenda, NMA Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda. NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mrg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Si Accumulator C Relief Valve NIA N/A N/A RV-4-858C NIA Corrected N
7. Description of Work:

Replace bolting

8. Tests Conducted: Hydrostatic. N/A Pneumatic NIA Nominal Operating Pressure NIA Other NIA Pressure N/A psig Test Temperature NzA deg F 05-056-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NWA Expiration Date: N/A Signed = - I SI Date Il17/1t Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspected the components described In this Owners Report during the period of 5-I - p 5 to a-1 60- O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. _______ Commiss ions Inspector's Signature National Board, State, Providence, and Endorsements Date _-_ __ _- Os-", 05-056-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 6128/2005 Name 700 Universe Blvd. Juno Beach. FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34011649-01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Orgartization, P.O. No. Job No, etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp WA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Safety Injection Accumulator System #: 64 Quality Group B
5. (a) Applicable Construction Code B31.1 1955 EditIon. N/A Addenda, NWA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 Edition. 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No SI Accumulator A" Relief Valve N/A N/A N/A RV-4-858A NIA Corrected N
7. Description of Work:

Replace inlet flange bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature N/A deg F 05-057-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. WA Expiration Date: N/A Signed s 1 4Z 1 -S 0 vo &-V" , S 6 - Date gII 16 !, Owner or Owner's Designeel Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut. have Inspeqlod the components described In this Owners Report during the period of 3 -T- to - I' -Gasp and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions Ad (d, w J Inspector's Signature National Board, State, Providence, and Endorsements Date 8.idA- og 05-057.4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 6/28/2005 Name 700 Universe Blvd. Juno Beach. FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Namne WO#: 34012259-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No., etc.
3. Work Performed by Florida Power and Lght Co. Type Code Symbol Stamp NIA Namre Authorization Number N/A 9760 SW 344 Street Florida City. FL 33035 Address Expiration Date NIA
4. Identification of System: CVCS Boron Addition and Recycle System #: 46 Quality Group B
5. (a) Applicable Construction Code B31.1 19 55 Edition, NIA Addenda. NA _Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1998 EdItion, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Emergency Boration Control NIA N/A N/A MOV-4-350 NIA Corrected N ValveN
7. Description of Work:

Replace bonnet bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic NMA Nominal Operating Pressure NIA Other N/A Pressure N/A psig Test Temperature N/A deg F 05-058-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signedi g n e t 1i) 51 Vs 6 Date lI 1 62/b Owndor Owners Designee. Tte CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT ol Hartford, Qnnecticut. ha e nspecd the components described In this Owners Report during the period of a o t-Z / and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners! Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

                           ,&4           4                                           Commissions        z     47?    L(4,      41, )

Inspectors Signature National Board, State, Providence, and Endorsements Date _ _ _ _ _ 05-0584

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 11/25/2004 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name, WO#: 34000318-01 CR#: N/A 9760 SW 344 Street Fiorida City, FL 33035 Address Repair OrganizaUon, P.O. No, Job No., stc.
3. Work Performe db)I Florida Power and Ught Co. Type Code Symbol Stamp NIA Name Authorization Number NMA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Main Steam System #: 772 Quality Group B
5. (a)Applicable Construction Code B31.1 19 55 Edition, NIA Addenda, N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg M~g Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Main Steam Line IC' isolation NIA N/A N/A MOV-4-1402 NfA Corrected bypass valve N
7. Description of Work:

Replace valve bonnet and bolting

8. Tests Conducted: Hydrostatic: NA Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 996 psig Test Temperature 287.7 deg F 05-0594

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUiRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: N/A Signed _ _ )v- X 5Date _________ Oewner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBQT of Hartford. Connecticut, have Inspqpted the components described Inthis Owners Report during the period of 7-2 9 to _ _ _ _ _ and state that to the best of my knowledge and beflef, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. Inspector's__________ Commissions A

  • W7(7 4 '*C; Inspector's Signature National Board. State, Providence, and Endorsements Date ?J - 3
                                                   <0 05-059-4

FORM NIS.2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Ught Co. Date 7/612005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address
2. Plant Turkey Point Plant
                                      . _.. ._1, . _. . . .

Unit 4 Name WO#: 35003432-1 01 CR#: NIA 9760 SW 344 Street Florida City, FL 33035 Address Repair Organlzallon, P.O. No, Job No., otc.

3. Work Performed byF Florida Power and Light Co. Type Code Symbol Stamp N1A Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Residual Heat Removal System #: 660 Quarity Group A
5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No RHR Inlet Valve N/A N/A N/A MOV-4-750 N/A Corrected N
7. Description of Work:

Replace Bolting material

8. Tests Conducted: Hydrostatic: NIA Pneumatic NIA Nominal Operating Pressure N/A Other NWA Pressure N/A psig Test Temperature N/A deg F 05-060-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed n - 1 SI S tD iQ V'  ; tOfr Date 81 1be 5 Owner or Owner's Designee, TItle ' CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a vand commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Forida and employed by HSBCT of Hartford, ConnectIcut, have Inspecgd the components described In this Owners Report during the period of - t_ to _ _ __-_OT_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Imptied, concerning the examinations and corrective measures described In this Owners' Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

                                        /      )e4X*~~*?~'                           Commissions         A      /7741X      C  A      J Inspectors Signature                                 National Board. State. Providence, and Endorsements Date          r-es-      0s 05-060-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 711212005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34001668-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization. P.O. No, Job No, etc.
3. Work Performed by Florida Power and Lkiht Co. Type Code Symb Dl Stamp N/A Name Authorization Nuniber N/A 9760 SW 344 Street Florida City, FL 33035 N/A Address Expiration Date
4. Identification of System: Reactor Coolant System #: 41 Quality Groul p A
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda. N/A Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Pressurizer Safety Valve N/A H51249- N/A RV-4-551A N/A Removed N 1362N Pressurizer Safety Valve N/A H51249- N/A RV4-551A N/A Installed N 1579
7. Description of Work:

Replace Valve with Spare

8. Tests Conducted: Hydrostatic: WA Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 2286 psig TestTemperature 548 deg F 05-061-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A 4 Signed *I S. I ,C'opefv i soize Date A>lI 1 )loS Owner or Owner's DesigneeVitle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have inspeed the components described Inthis Owners Report during the period of - S O" to .L-Ji and state that to the best of my knowledge and berief. the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Impried, concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shahl be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with thIs Inspection.

                     .:4              /             ?                                Commissions A4 77 go c; ',A Inspector's Signature                               Nabonal Board, State. Providence. and Endorsements Date      rw-<<A 05-061-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 71712005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34001669-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization P.O. No, Job No.. etc.
3. Work Performed by Florida Power and ULIht Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Reactor Coolant -System #: 41 Quality Group A
5. (a)Applicable Construction Code B31.1 1965 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section XI Utilzed for Repairs or Replacements 19 98 Edition, 2000 Addenda, NIA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Pressurizer Safety Valve NIA N6987700 NA RV-4-551 B N/A Removed N 0005 Pressurizer Safety Valve N/A N698770D NWA RV-4-551 B N/A Installed N 0004
7. Description of Work:

Replace Valve and bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure X Other N/A Pressure 2286 psig Test Temperature 548 deg F 05-062-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: N/A Signed -,- S z 1as DI itie do; C.V n Datea I l 7 5 Owner or Ownxer'sDesignee,ll'tle J J CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut, have Inspected the components described in this Owners Report during the period of 5 O- to 7-i7-Ois< and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code. Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

                        /        , 4       A      Z/                                   Commissions                              s4 .7Z)

Inspector's Signature National Board, State, Providence. and Endorsements Date 05-062-4

FORM NIS.2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 7n/72005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34001670-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No. Job No.. etc.
3. Work Performed by Florida Power and Light Co. Type Code Symbol Stamp N/A Name Authorization Number NIA 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Reactor Coolant System #: J41 Quality Group A
5. (a)Applicable Construction Code B31.1 19 55 EditIon, NIA Addenda. N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 9B Edition, 2000 Addenda. N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Pressurizer Safety Valve N/A H51249- N/A RV-4-551C NA Removed N 1361 Pressurizer Safety Valve NA H51249- NIA RV-4-551C N/A Installed N 1581
7. Description of Work:

Replace Valve and some bolting

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 2286 psig Test Temperature 548 deg F 05-063-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTiFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date: N/A Signed - I & Date 8I1 705 1 Owner or Owner's Designee, Titie CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding avalid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford. gpnnecticut. have Inspected the components described In this Owners Report during the period of ,/&f.IT, 0 to w,4- a5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certilicate neither the Inspector nor his employer makes any warranty, expressed or Implied. conceming the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions 4AidZ( HCC va -r) Inspectors Signature National Board, State, Providence. and Endorsements Date -Pf%6 05-063-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 711212005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet i of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 35000440-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No,. etc.
3. Work Performed by Florida Power and Lght Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: CVCS Charging and Letdown System #: 47 Quality Group A
5. (a)Applicable Construction Code 131.1 19 55 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1998 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identificatlon Built Installed Yes/No Excess Letdown Thermal N/A NIA N/A RV-4-304 N/A Removed Relief ValveN
7. Description of Work:

Remove RV from system, Cap pipe

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure NIA Other N/A Pressure NWA psig Test Temperature N/A deg F 05-064-4

Sheet 2 of 2 . FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: N/A Signed __ __ _ __ __ _ __ _ __ __ _ __ __ s_1o_ 1 _ __I __ _ __ __ _ __ _ Date 8_ _ _ _ _ _ _O _ Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTiON I, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford Connecticut. have Inspe the components described in this Owners Report during the period of 4-q a.s- to %7-n o and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the examinations and corrective measures described In this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. 7

  • 4 Commissions f14?S(4,4C,)

Inspectors Signature National Board, State, Providence, and Endorserelt Date______ _ 05-0644

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Florida Power and Light Co. Date 7/11212005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO# 34012046- 01 CR#-. N/A 9760 SW 344 Street Florida City, FL 33035 Address Repair Organization, P.O. No, Job No.. etc.
3. Work Performed b)I Florida Power and Light Co Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Reactor Coolant System #: 44 Quality Group A
5. (a) Applicable Construction Code B31 .1 19 55 Edition, N/A Addenda, NIA Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4C Reactor Coolant Pump NIA NIA N/A 4P200C N/A Corrected N
7. Description of Work:

Replace rotating element Including main flange and one stud

8. Tests Conducted: Hydrostatic: NIA Pneumatic N/A Nominal Operating Pressure X Other N/A Pressure 2286 psig Test Temperature 548 deg F 05-065-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code. Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed -. i L SI Q e DV/ Date &' 1 71 5 Owner or Owneres Des;ignee, Tite I CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford Connecticut, have Inspegled the components described in this Owners Report during the period of _ _ _ _ _ _ to '-/9-os and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners' Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described In this Owners ReporL Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. If commissions Ae 4'77 ! C c>, Inspector's Signature National Board. State, Providence, and Endorsenments Date ___ __ __ 05-065-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power and Light Co. Date 7/112/2005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I _ of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34012046i 02 CRt: NWA 9760 SW 344 Street Florida City, FL 33035 Address Repairorganizanon, r .. No, Job No., etc.

r

3. Work Performe Ib) Florida Power and Light Co. Type Code Symbol Stamp NIA Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date NIA
4. Identification of System: Reactor Coolant System # A4 Quality Group A
5. (a)Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, NIA Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, NWA Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No 4C Reactor Coolant Pump NIA N/A N/A 4P200C NIA corrected N
7. Description of Work:

Reweld/Realign pipe and flange to seal

8. Tests Conducted: Hydrostatic: . WA Pneumatic NIA Nominal Operating Pressure N/A Other NIA Pressure N/A psig Test Temperature N/A deg F 05-0664

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED INACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date: N/A Signed IS1 iSoe3rV`111- Date 8lf 1U/05S Owner or Ownees Designee, tild CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a varld commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford, Connecticut. have Ins!cted the components described Inthis Owners Report during the period of J-4 -o- to S'-/9 eoh and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. A7-4 4426  ; Commissions i,5'61i,41C J Inspector's Signature National Board. State, Providence, and Endorsements Date _ _ _ _ _ 05-066-4

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Florida Power and Light Co. Date 711312005 Name 700 Universe Blvd. Juno Beach, FL 33408 Sheet I of 2 Address
2. Plant Turkey Point Plant Unit 4 Name WO#: 34003357-01 CR#: N/A 9760 SW 344 Street Florida City, FL 33035 Address gepair Organization, P.O. No, Job No., etc
3. Work Performed by Florida Power and Licht Co. Type Code Symbol Stamp N/A Name Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 Address Expiration Date N/A
4. Identification of System: Containment Airlocks I Hatches System #: 51 Quality Group B
5. (a)Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 98 Edition, 2000 Addenda, N/A Code Case
6. Identification of Components Corrected or Removed and Installed Components ASME Corrected, Code Name of Name of Mfg Mfg Serial National Other Year Removed or Stamp Component Number Board Identification Built Installed Yes/No Unit 4 Equipment Hatch N/A NA NIA 4S10 NIA Corrected N
7. Description of Work:

Replace some bolting material

8. Tests Conducted: Hydrostatic: N/A Pneumatic NWA Nominal Operating Pressure N/A Other N/A Pressure N/A psig Test Temperature NWA deg F 05-067-4

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REOUIRED.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date: NIA Signed I S7IS U!Rewf go Date toI I 1 oC Owner or Owner's Designee, Title' I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the state of Florida and employed by HSBCT of Hartford Connecticut, have insppted the components described In this Owners Report during the period of __________ 5_ to f-ia-O . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners' Report In accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described inthis Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. _ _ _ _ __ / Commissions ci f, t C x) Inspectors Signature Natlonal Board, Slate, Providence, and Endorsements Date e______ 05-067-4}}