LER 89-015-01:on 890721,while Attempting to Remove Malfunctioning Reactor Pressure Vessel Regulator Set,Bypass & Control Valves Opened,Causing Steam Line Pressure to Increase to 480 Psig.Components replaced.W/900116 Ltr
ML19354E010
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 01/16/1990
From: Cribbe T, Danni Smith
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
LER-89-015, LER-89-15, NUDOCS 9001250197
Download: ML19354E010 (7)


Text

-

.CCN-90 1401g

, =.

' PHILADELPHIA ELECTRIC COMPANY PIACilllOTIUM ATOMIC POWlR S1ATION R. D. I, llox 208 Delta, Itnnsylvania 17314 nua nomm-tm routa os a scantwt (717) 456-7014 D. M. Srnith Ykr Prnident January 16, 1990 Docket No. 50-277 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555

SUBJECT:

Licensee Event Report Peach Bottom Atomic Power Station - Unit 2 This LER involves a reactor scram resulting from an attempt to remove a malfunctioning Electro-Hydraulic Control System component from service. This revision provides additional information on the malfunctioning component.

Reference:

Docket No. 50-277

Report Number: 2-89-015 Revision Number: 01 Event Date: 07/21/89 Report Date: 1/16/90 Facility: Peach Bottom Atomic Power Station RD 1. Box ~208, Delta, PA- 17314 The revision to this LER is being submitted pursuant to the requirements of10CFR50.73(a)(2)(iv).

i Sincerely, cc: J. J. Lyash, USNRC Senior Resident Inspector-W. T. Russell, USNRC, Region I 9001250197 900116 PDR ADOCK 05000277 k\

S PDC

i MC f 6rs 304 U S. NUCLE AR kt1ULATORY COMMIS$10N

+ MitOvt0 DMB ND 3164tr1M

' "';a' $ ' '8'

  • LICENSEE EVENT REPORT (LER)

F ACILITY NAME til DOCalY NVuttR L21 ' AGE $3-Peach Bottom Atomic Power Station - Unit 2 0 lb l 0 l0 l 0 l2l 7l7 1 loFl Q Malfunctioning-Electro-llydraulic Control System Component Causes Scram When Removed Prom Service EVENT Daf t (Si LtR NUheRER gg# RIPOnf oaf t 471 CTMt R 9 ACILif tt s INv0LvtD lei DOC AS T NUMpt Rtle

%N L*4 Q,Wf7 *AciteTw havns MONTH DAY vtAR vtAR MONTM DAY vtAR 0 15101010 1 I I

~ ~

ol7 2l1 8 9 8l9 ol1 lL ol1 ol 2 1l6 9l 0 0 l 61 0 l0 1 0 i l l TMt3 REPORT 88 $UsurTTED PURSUANT TO TMt at OUIREMENTS Of to CF R h- (Caeca on, or me,e e,,ae ,eereneapp fin opt R Af tNG MODI m N ,,,,,,,, ,,,,,,,, y ,,,,n,,,,,, ,3.,,,,,

f 70 4061sH1Hd 90 38teH16 60 73teH2Hel T3.?tiel (10) 1 01719 so soni.HiH.i s02sisim _

50.73.H H.=>

_ gTMi, gsgga,*p,7,e, 20 406teH1 Heil 50.tStel(2 nd 50 73teH2Hveill Al J66A 8 20 608telt1 Hest 60.73 el(2 Heil 90 73 ell 2Hv4Mit!

20 totteH1 Hel 60.73 eH3H460 to.731eH2Hal LICIN$tt CONT ACT FOR THIS Lt R litt NAME TE L tPMOht NUMBER Asit & Copt T. E. Cribbe, Regulatory Engineer 71117 41516 l-17101114 COMPLET4 ONE LINE FOR 4 ACM COMPONENT F AILURE DESCRIDED IN 7 Mil R4 PORT (131 LE "A * " '

CAust 8vsTtM Cou'ONENT MAN g (AC R E 'OR,1,A CAust syst t M CoMooNtNT ut o >R X TIG l l PIE G 1018 l 4 Y I i l l l l l l l l 1 I I i 1 1 I I l l l

$UPPLEMtNT AL REPORT E K'tCTED 114l MONT H DAY vtAR 455 Ilf ,es remow,e $KPECTfD $UgstIS$10N OA TL) NO l l l

. 1 R A C T m. . . e ,,,,.. - ., . . -, ,,,,-,,.. ,. , n .3 At 2231 on 7/21/89 with Unit 2 at 79% thermal power, an attempt was made to remove a malfunctioning Reactor Pressure Vessel (RPV) Pressure Regulator Set from the electronic portion of the Main Turbine (MT) Electro-Hydraulic Control (EHC) Pressure Regulating System. Immediately, the MT Bypass and Control Valves opened, causing main steam line pressure to decrease to approximately 480 psig. At 850 psig main steam line pressure a Group I Isolation occurred causing the Main Steam Isolation Valves (MSIV)toclose. As a result, a full reactor scram occurred. RPV level decrease due to shrink following MSIV closure resulted in a Group II and III isolation as level decreased below 0 inches. Two Main Steam Relief Valves (MSRV) lifted once. automatically, followed by manual Operator cycling of MSRVs to control RPV pressure between 930 psig and 1060 psig. The High Pressure Coolant Injection (HPCI) and Reactor Core Isolation Cooling (RCIC) systems were placed in operation to control RPV pressure and level. The root cause of this event was a malfunction of

, the electronic portion of the "A" RPV Pressure Regulator Set. No actual safety consequences occurred as a result of this event. The majority of the "A" Regulator electronic components were replaced. This event has been reviewed with appropriate I plant personnel.. One previous similar LER was identified.

__ ._ _ _ ._ _ _ _ _ _ _ ~

anc v4 wucten4:vutony commissio=

" P-. aspa UCENSEE EVENT REPORT (LCJ TEAT CINTINUADON m novtooueim 3 % em -

  • EXPatt:l'31C P ACILifv esaaet (16 o0CKti 88Uniten (#1 ten edumeth ten PA04 (31 Psach Bottom Atomic Power Station '8 '" l '  % 3" WU Unit 2 0 l5 J O l0 l0 l 2 l 7l7 8l 9 -

o ll l 5 -

ol l ol 2 or ol6 nxt u . o c w aww nn Requirements for the Report ~

This LER is being submitted pursuant to'10CFR50.73(a)(2)(iv) to report those conditions which resulted in the automatic actuation of an Engineered Safety Feature i.e., Reactor Protection System (EIIS JC) and Primary Containment Isolation System ,

(EIIS:JM).  :

Unit Status at Time of Event  !

Unit 2 was in the Run Mode at 79% thermal. power increasing generator (EIIS:TG) load l at a rate of 10 MWe per hour. Unit 3 was in the Refuel Mode with the core offloaded. i Unit 2 "A" RPV Pressure Regulator (EIIS:RG) Set output signal was drifting slowly upward at a constant rate (pressure decreasing).

Description of Event NOTE: TheMainTurbine(MT)(EIIS:TRB) Electro-HydraulicControl(EHC)(EIIS:TG) (

, Pressure Regulating System consists of two redundant Pressure Regulator (E!IS:RG) j Sets which maintain constant reactor (EIIS:RCT) pressure in coordination with MT i speed and load control.

On7/3/89whileperformingMTEHCPressureRegulatingSystemstabilitytesting-(with  !

the "A" Pressure Regulator in service) it was noted that the signal output from "B" Pressure Regulator circuit was offset from the "A" approximately 15 psig (normal 3 psig). The offset was returned to the 3 psig setting by adjusting the pressure [

setpoint bias potentiometer. Continued observation revealed the pressure  ;

differential between regulator circuits to be increasing requiring periodic bias  :

potentiometer adjustments to maintain 3 psid between channels (EIIS:CHA).. Testing '

indicated the "A" Regulator signal output was increasing slowly (causing pressure to  :

decrease 0.4 psig/ day), while at the same time "B" Regulator signal' output appeared stable. It was noted that the bias potentiometer was quickly-running out of adjustment requiring action before a loss of the ability to maintain the required 3 +

psid between regulators occurred. The 3 psid value is required to enable a ,

relatively smooth transfer to the redundant regulator in the event of failure of the -

regulator in service. On 7/20/89 the Plant Manager was informed of the problem and options available.

-On 7/21/89 a meeting attended by the Plant Manager, System Engineering, Shift Supervision and a General Electric (GE) representative with a knowledge of EHC was held to evaluate each available option and its associated risk.in order to determine an action plan. After a review of the technical information available and with the concurrence of the vendor representative the decision was made to transfer control to the stable "B" Regulator and disable the "A" Regulator by removing the "A" Steam Line

  • Resonance Compensator (SLRC) card (A-42 card) from the electronic portion (see attachment) of the MT EHC Pressure Regulating System. This course of action would;
1) provide a stable and reliable pressure regulator, 2) eliminate the need for bias pot adjustments and 3) eliminate the potential loss of Reactor Pressure Vessel (RPV) pressure control if degradation of the "A" Regulator continued or accelerated and 4) '

utilize the least complex method of disabling the "A" Regulator, Similar card-removals had been performed at Limerick Gereerating Station and several plants of other utilities without experiencing system transients. .

,.,,,...m. _ .,..r,, _m,- #.-.. ,- __

I Z3CFeem W .. U.S. 08UCLE13 $_EIUL&To#7 COhs.48#4one l

  • UCENSEE EVENT MEPORT H.ER) TEXT CONTINUATION unovio oue No. mo-oios teints:a m o
. F AC4Li(Y esAtst $11 DOC 8LET NutAtth til LIR NUnseth fel PAGE (3)

P@achBottomAtomicPoweEStation " "Wik" man l

-Unit 2 l l 0 l5 ln l0 l0 l 2l7 l 7 8l9 -

ol1]5 -

oli ol 3 oF ol6 i mvn m

..- w.m 1

The intent was to operate on the "B" Regulator only and leave the "A" Regulator out l of service until the next shutdown. j At 2231 on 7/21/89 with Unit 2 at 79% therral power, an attempt was made to remove l the malfunctioning "A" Pressure Regulator Set from the electronic portion of the MT i EHC Pressure Regulating System. This-was to be accomplished by pulling the SLRC l circuit: card. .The individual removing the card had difficulty on the first attempt, 1 while repositioning his grip for a second attempt a slight side to side movement occurred. Before card removal, could be completed several relay actuations were heard and the Plant Manager in conjunction with the vendor representative halted 1 removal.

l Immediately, the Main Turbine Bypass and Control Valves opened, causing main steam '

line pressure to decrease to approximately 480 psig. At 850 psig main steam line pressure, a Group I Isolation occurred causing the Mein Steam Isolation Valves i (MSIVs) to close. As a result, a full reactor scram signal occurred due to MSIV 1 closure. Initially, RPV level increased due to swell as a result of RPV pressure  :

decrease, then decreased due to shrink as RPV pressure increased following MSIV I

I closure. This resulted in a Primary Containment Isolation System (EIIS:JM) Group II  :

and III isolation signal as level decreased below 0 inches (172 inches above the l core). Isolation of the Reactor Water Cleanup System (EIIS:CE), drywell equipment i and floor drain sumps (EIIS:WD), drywell and torus instrument nitrogen supply (EIIS:LK)._and reactor building ventilation (Ells:VA) occurred as a result. RPV  :

level decrease stopped at -35 inches, then level increased as Reactor Feed Pumps {

(EIIS:P) (RFP) "A", "B" and "C" continued to provide makeup. The RFPs were tripped i before level exceeded +45 inches, level peaked at +75 inches and then decreased as  :

automatic are manual Main Steam Relief Valve (MSRV) (EIIS:RV) operation reduced RPV 't inventory. Yorus (EIIS:BS) cooling was placed in operation in anticipation of the  :

decay heat removal-requirements for the isolated reactor. RPV pressure increased to  :

approximately 1100 psig during the transient and the following sequence occurred; I) -

an Alternate Rod Insertion (ARI) High' Pressure backup scram occurred at 2238 2) MRVs l "J" and "H" lifted once automatically at 2242 and 3) the Operator manually cycled MSRVs "A", "B", "K" and "C" once each to reduce and maintain reactor pressure at 930 -

psig to 1060 psig between the time 2242 and 2258. Both Reactor Recirculation pumps tripped as expected during a 13 KV Auxiliary Bus (EIIS:BU) Fast Transfer caused by a L MT trip initiated generator lockout'. The Reactor Recirculation (EIIS:AD) pumps were'.

Subsequently restarted to provide forced circulation. The scram and Group 11 and III '

isolations signals were reset at 2305. The High Pressure Coolant Injection (EIIS:BJ)

(HPCI) and Reactor Core Isolation Cooling (EIIS:BN) (RCIC) systems were placed in  :

operation to control RPV pressure and level. HPCI was maintained in the full flow  ;

test mode (Condensate Storage (EIIS:KA) Tank (CST) to CST) to remove decay heat while RC!C was utilized to control RPV level. The unit was stabilized in the Hot Shutdown t condition at 2313.

P t

.v.s. cro, i,es-no....,ooo ro :

pg. eoxu mn

=ac .:

P , p* * .en M

. ut auct4aut utatoav commerion

'J UCENSEE EVENT REPORT (LER) TEXT C3NTINUATION - movfo ove no. mo-oio.

. EXPWits: 8/31/M PACILITY esAMS (11 DOCKtttouuBERtal Lan NUMeta (4) Pact (3) '

P2ach' Bottom Atomic? Power Station' """ '-

"UE '

"Eu'aN Enit 2 Text sn ew, as m espeac un asumeant mac rean ama myn -

0 l5 l0 l0 l0 l 2(? l? Bl 9 -

olll5 -

o \1 o I4 oF 'ol6

' Cause of-the' Event i[Therootcause-ofthisevent'wasthe' unusual-' service-conditionresultingfromt malfunctioning component preceding the attcmpt to remove the malfunctioning.Preem.

l Regulator Set from-the electronic portion of the RPV Pressure Regulator System. .The=

malfunctioning component was found to be the "A" Main Steam Pressure Transducer (PT-

- h84)-(Ells:PT). which drives;the "A" Main Steam Pressure Sensor (Dwg. No.'832E840GR1)

Pressure;)(i.e.. more~open control valves). . Warm moist' air.from the moisture.(E separator area condensed in the electrical conduit resulting in; water damage to the transducer. The water camaged transducer affected the performance of the "A" pressure channel. sThis anomaly' precipitated the evaluation, decisions and'actionsi taken as addressed in the Description of Event.-

The catst of the EHC transient was determined-to be the intermittent removal of thel-

30. volt supply to the'"A" Pressure Regulator.and'the voltage transients that' resulted.'lnis' voltage fluctuation apparently was caused-by the slight side to. side movement that occurred during the. attempt to remove the SLRC circuit card.

. Analysis of the Event a

No. safety consequences occurred as a result of this event.

m The Reactor Protection _ System (RPS) and Primary Containment Isolation Systems (PCIS) operated properly throughout the. transient. 'The other Safety systems responded properly as described in the Description of Event. .Due to the close proximity to -j ful1 power atlthe start of.the event, the expected plant response at-100% power would not have differed significantly.

Corrective Actions '

1 The following corrective actions have been taken:

, 1. The Main Steam Pressure Sensor was returncd to the1 vendor (GE) for analysis.

A It was evaluated and found:not to have any defects. -

2. The "A" Pressure Regulator circuit cards with the exception of the SLRC and Operational Amplifier were replaced and calibrated.
3. The "A."

SLRC has.been bench tested satisfactorily withoat identifying ~any deficiencies. jl

4. RPV pressure has been monitored from.the Control Room since returning to power i and set p ersure has-not displayed any drifting characteristics.

1 S. This event has been reviewed by appropriate plant personnel.

11 6. The "A".and

l -

prevent water"B" Main Steam intrusion. Pressure Transducers were sealed.at the transducer to .

1 y

- ~"

e... m . ,... m . e -

NRC fosm atla . U 8 itVCLtan s.51ULATORY COMMtBS1088 7'

  • LICENSEE EVENT REPORT (LER) TEXT' CONTINUATION maovto oMe No mom EXPIRES. 8/31/2 P ACILITY NAME (1) DOCKni NUMSth GB LER NUMBER (gp , PAGE Di lPaach Bottom Atomic Power Station '" " Na '

EYaN Unit 2 - -

Ol6l0l0l0l2l7l7 8l9 -

0l1l5 -

011 0l 5 OF o l6 TEXT rX more spece As rueursef, see adutoonsIN4C Fonn JNAW 11h 5

l 7. The Preventive Maintenance.(PM) Program was enhanced to include: a) an inspection of each pressure trarr.ducer during each recalibration, and b) .i replacement of both pressure transducers every third refueling outage.

The-following corrective-action is planned:

l 1. The conduit from the moisture separator area will also be sealed.

Previous Similar Events There was one previous similar LER associated with troubleshooting the EHC System

.that resulted in a reactor scram. The following is a brief description of the event and those actions taken to prevent recurrence: .-l LER 3-87-02 addresses a low reactor water level scram caused by a main steam transient while performing testing on the EHC System. This testing was being-performed to ensure the corrective actions taken in LER-3-87-01 to eliminate EHC signal oscillations were effective. Corrective actions for this LER included having .

.a vendor representative and other personnel knowledgeable in the.EHC System present while testing. .

f This action to prevent recurrence would not have prevented this event. Personnel experienced in the operation, maintenance and testing of-the EHC. System, including the Plant Manager and the knowledgeable vendor representative were present or .

involved throughout the testing / troubleshooting and decision making process.

I f

4-

'i i

hs NRC FORF 304A 'U.S. CPO, 1988-520 589r00010 -

C43) -

Ig . y qc p g

l o ,,

2, . ,, o . a W t2 .. - ^

1i  :

4, l "h~

I ',e , ,

n

. g, ,- ,

= . . :1 g *

h 'O B ~

RPV Pressure Control 5

.g l a r ..

o-C.

o

-} .m w i.seS w e, r.n # w stac-4 a' lll T PT :g. m

-. t ~

. l

. m

'[~ 's* M *"-

Q.

kl O, y f

e 1 wst e 1,

g x/

/

_I._

. =

3r.

o.

sH 3-

. m

-ImmL 1 g

o .g E

. ~

v=

s.r

-I h-y I _ m _a .p,,,,,,, o- [

. to.d sai. .

o -

f I- N

.O:

O" z

T MSPS T Pressure Regulator -B*SLRC -

T PT u

d z-O

"'*""- ~

g'I S .[

.I k ,

L 1 3 \c , t e

=

d~

o

.I;

~

vu g / ': g

- .z.

. =

e tg gL.= o

_ g{ g

+ g; a

  • "5 5 5 l 1 ~{e as

? Legend: ~ Attachment 1 ' _

jj .. ~ l

[ PT --Pressure Transducer * =!

h,'{j

.3 MSPS - Main Steam Pressure Sensor o 8k Ef.j

~

,3 SLRC - Ste&m Line Resonance Compensator m ,

o E .8a

o g 5 C' ;I s

e.., -~ ~ _ - -

f 3 my. _

,r,.#.+ 1 r '-w--~