05000000/LER-1986-009, Ro:On 860312,discovered That LER 2-86-04 & LER 86-009 Not Submitted to Nrc.Caused by Misplaced Repts.Repts Telecopied to Nrc.Procedure for Distribution of Repts Revised | 14 April 1986 | Ro:On 860312,discovered That LER 2-86-04 & LER 86-009 Not Submitted to Nrc.Caused by Misplaced Repts.Repts Telecopied to Nrc.Procedure for Distribution of Repts Revised | |
ML20055B518 | 13 July 1982 | RO Advising That Triaxial Accelerometer Devices in Reactor Core Isolation Cooling Sys Pump Room Inoperable for More than 30 Days.Replacement Detector to Be Installed by 820831 | |
ML20056G870 | 27 August 1993 | Special Rept:On 930803,discovered That Cylinder on 2-EDG Lower than Normal Operating Temps.Caused by Fuel Pin on Cylinder Injector Pump Not Fully Engaged | |
ML20058B710 | 14 July 1982 | Ro:On 820619,during Scheduled Loss of Power Test on Unit 2, Inadvertent Startup of ECCS on Unit 3 Initiated While at Full Power.Caused by Defective Elma Dc Power Supply to 24-volt Dc Logic Circuit | |
ML20058N665 | 8 August 1990 | Special Rept:On 900802 & 07,diesel Driven & Motor Driven Fire Pumps,Respectively,Declared Administratively Out of Svc.Caused by Engine Overheating & Diesel Generator (DG) E-2 Out of Svc.Local Fire Depts Notified & DG E-2 Repaired | |
ML20059A827 | 22 October 1993 | Special Rept:On 931012,valid Failure of EDG E-2 Occurred During Routine Monthly Test.Edg E-2 Declared Inoperable Due to High Fuel Oil Differential Pressure Condition.Edg E-2 Fuel Oil Filters Replaced | |
ML20059B899 | 21 August 1990 | Special Rept:On 900802,diesel Driven Fire Pump Declared Inoperable During Testing Due to Engine Overheating.Diesel Generator E-2 Returned to Operable Status & motor-driven Fire Pump Declared Operable on 900807 | |
ML20062C316 | 11 October 1978 | Rept Occurrence 2-78-41/1P:on 781010 During Routine Surveillance Test of Unit 2 4KV Undervoltage Relays,Setpoint of Bus Sequence Loading Relays E-32 & E-42 Were Out of Calibr,Due to Engr Error | |
ML20062J851 | 6 November 1980 | Ro:On 801106,during Increase of Reactor Power from Hot Standby Condition,Main Steam Bypass Valve 3 Exhibited Erratic Operation.Caused by Defective Circuitry Board. Board Removed.Stable Pressure Control Sys re-established | |
ML20062J852 | 6 November 1980 | Ro:On 801105,while Performing Routine Surveillance Test on HPCI Sys,Hpci Observed to Start,Trip & Restart in Succession Several Times.Caused by Open Resistor Which Provides Input Power to Emergency Generator Motor.Component Replaced | |
ML20062L016 | 5 January 1981 | RO 2-81-02/1P:on 810105,at 100% Power,During Surveillance Testing,Reactor Core Isolation Cooling Pump Flow Indication Observed Upscale W/Pump Secured.Caused by Failed Square Root Extractor in Flow Control Loop.Extractor Replaced | |
ML20062L218 | 14 January 1981 | RO 2-81-4/1P on 810114:diesel Generator E3 Output Breaker to Unit 2 Emergency Bus Failed.Cause Unknown.Failed Breaker Replaced | |
ML20062L528 | 13 January 1981 | RO 81-003/01P-0:on 810113,leak Discovered on Oil Supply Line to Turbine Manual/Overspeed Trip Mechanism of HPCI Auxiliary Oil Pump.Probable Cause Due to Leaking Valve or Fitting in Supply Line.Investigation Underway | |
ML20064A465 | 27 August 1990 | Special Rept:On 900802,diesel-driven Fire Pump Declared Inoperable During Testing Due to Engine Overheating.Caused by Silt & Marine Biotic Life Plugging Y Strainer in Cooling Line.Strainer Cleaned & Retested | |
ML20064C301 | 28 February 1994 | Special Rept:On 940211,non Valid Failure of EDG E-4 Occurred When Voltage Shutdown Button Inadvertently Bumped.Maint Insp Initiated to Determine If Generator Damage May Have Occurred Due to Event.Remaining EDGs Were Operable | |
ML20064E050 | 19 October 1978 | Reportable Occurrence 3-78-20/1P on 781019:while Unit 2 Was Being Inerted,Unit 3 Drywell Oxygen Concentration Exceeded Tech Spec Limit by 0.1%.Drywell Was Depressurized & Purged to Bring Oxygen Concentration W/In Limit | |
ML20066A581 | 28 October 1982 | RO 2-82-36/1P:on 821024,71J Safety Relief Valve Opened When Pressure Reached 832 Psig.Cause Unknown.Valve to Be Sent to Vendor.Two Vacuum Breakers Replaced.Fatigue Analysis Determined Downstream Piping Not Overstressed | |
ML20066A939 | 25 October 1982 | Ro:Response Spectrum Analyzer Component of Seismic Monitoring Sys Intermittently Inoperable Since 820909.Caused by Malfunctioning Power Control Card.Card Will Be Replaced. Component to Be Returned to Svc by 821130 | |
ML20069L317 | 11 April 1983 | Corrected RO 3-83-11/1P:on 830407,full-in Position Signal Jumpered Into Probe Buffer Cards.Control Rods Could Have Been Withdrawn W/O Initiating Single Control Rod Interlock. Caused by Personnel Error.Jumpers Removed | |
ML20071Q577 | 2 August 1994 | Special Rept:On 940706,valid Failure of E-4 Emergency Diesel Generator Occurred.Caused by Solenoid Valve Spuriously Sticking.Valves Replaced | |
ML20077P970 | 15 August 1991 | Special Rept:On 910714,diesel Driven Fire Pump Out of Svc for More than Seven Days Due to Annual Preventative Maint Activities.Preventative Maint Completed & Pump Returned to Svc.Operability Testing Completed Satisfactorily on 910723 | |
ML20078C170 | 24 October 1994 | Special Rept:On 940924,valid Failure of E-2 EDG Occurred. Caused by Problem w/4 Kv Breaker.Breaker Incorporated Into Preventive Maint Program to Replace Grease | |
ML20079L268 | 15 February 1983 | RO 3-83-08/1P:on 830214,three of Eight MSIVs Failed to Pass Tech Spec Limit of 11.5 Scfh & Containment Isolation Valve Mo 2-74 Failed Leak Rate Test.Caused by Abnormal Wear of Valve Internals.Valves to Be Inspected & Repaired | |
ML20079L629 | 30 October 1991 | Special Rept:On 910916 & 23,cable Spreading & Computer Room CO2 Fire Protection Sys Out for Svc for More than 14 Days. Caused by Need to Provide for Worker Safety During Mod Work. Fire Detectors Verified Operable & Firewatch Stationed | |
ML20080A773 | 16 January 1984 | Ro:On 831128,from 830830-1128,seismic Monitoring Sys Inoperable.Caused by Personnel Oversight.Startup check-off List Modified to Require Maint Request | |
ML20083P820 | 5 March 1984 | Ro:On 840125,moisture Sensor in Recirculation Sys Moisture Monitoring Sys Functioned Improperly & Sys Declared Inoperable.Caused by Failed Techmark Limited Moisture Sensor Circuit Card.Sensor Replaced | |
ML20083P963 | 12 March 1984 | Ro:On 840209,CO2 Fire Protection Sys,Serving Cable Spreading Room & Computer Room,Declared Inoperable.Caused by Ground in One of Two Cables from Smoke Detector Control Panel.Cables Replaced & Sys Available for Svc | Continuous fire watch |
ML20083Q023 | 23 March 1984 | Ro:On 840224,during Verification of Moisture Monitoring Sys,Point 7 Failed.Cause Will Be Determined During Next Outage W/Drywell Deinerted.Drywell Sump Collection Sys Will Be Monitored Hourly | |
ML20085M395 | 29 October 1973 | Ro:Describing Possible Backseating Disc Mislocation Problem on 2-inch Darling Valves on S-350 Wdd Welding End.Valves Repaired.Valve Stems Will Be Changed During Next Refueling Outage | |
ML20086F080 | 6 June 1977 | Ro:On 770506,plant Iodine & Particulate Release Rate Exceeded 4% of Facility Tech Spec Averaged Over Second Calendar Quarter of 1977.Caused by Fuel Perforations Coupled W/End of Cycle Testing & Reactor Coolant & Steam Leaks | Fuel cladding |
ML20086F307 | 21 September 1977 | Environ RO 77-25:on 770912,pH for Settling Basin Effluent Exceeded Ets.Cause Not Determined.Settling Basin Isolated & Neutralized.After Ph Check,Sys Returned to Normal Operation | Grab sample |
ML20086F309 | 6 September 1977 | Environ RO 77-23:on 770827,pH for Settling Basin Effluent Exceeded Ets.Caused by Syphon Created in Effluent Pipe. Settling Basin Isolated & Neutralized | Grab sample |
ML20086F312 | 10 August 1977 | Environ RO 77-22:on 770801,small Contained Oil Spill Observed at North End of Plant Site.Caused by Turbine Lube Oil Conditioner Losing Water Seal.Water Seal Level Readjusted & Storm Drain Flushed to Remove Residual Oil | |
ML20086F313 | 26 July 1977 | Environ RO 77-21:on 770716,total Suspended Solids for Sewage Plant Effluent Exceeded ETS 2.2.2 Limit.Caused by Efforts to Change Bacterial Strain Which Produced Low Ph During Digestive Process.Aeration of Sludge Tank Adjusted | |
ML20086F314 | 15 July 1977 | Environ RO 77-20:on 770706,pH for Settling Basin Effluent Exceeded ETS Limit.Caused by Operator Error.Settling Basin Isolated & Neutralized,Ph Checked & Sys Returned to Normal Operation | Grab sample |
ML20086F315 | 8 July 1977 | Environ RO 77-19:on 770628,pH for Sewage Plant Effluent Exceeded ETS Limit.Cause Under Investigation.Sewage Plant Being Operated Normally & Effluent Being Neutralized When Possible | Grab sample |
ML20086F316 | 5 July 1977 | Environ RO 77-18:on 770624,pH for Settling Basin Effluent Exceeded ETS Limit.Caused by Leakage of Two Valves Located Between Neutralizing Tanks & Demineralizer Regeneration Waste Sump.Settling Basin Neutralized | Grab sample |
ML20086F317 | 1 July 1977 | Environ RO 77-17:on 770622,pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Development of Bacterial Strain Which Produces Low Ph During Digestive Process.Plant Operated Normally.Normal Ph Reached in 2 Days | Grab sample |
ML20086F318 | 24 June 1977 | Environ RO 77-16:on 770614,pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Development of Bacterial Strain Which Produces Low Ph During Digestive Process.Plant Being Operated Normally | Grab sample |
ML20086F321 | 16 June 1977 | Environ RO 77-15:on 770606,pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Bacterial Strain Which Produces Low Ph During Digestive Process.Sewage Plant Operated Normally & within 3 Day Ph Limit | Grab sample |
ML20086F322 | 27 May 1977 | Environ RO 77-13:on 770517,total Suspended Solids for Sewage Plant Effluent Exceeded ETS 2.2.2 Limit.Caused by Sys Upset & Greater than Normal Water Input Due to Refueling Outage. Aeration Rate Adjusted | |
ML20086F323 | 18 April 1977 | Environ RO 77-11:on 770407,pH for Settling Basin Effluent Exceeded ETS Limit.Caused by Regeneration of Anion & Cation Demineralization W/O Verification of Closure of Neutralizing Pump Discharge Valve | Grab sample |
ML20086F324 | 1 April 1977 | Environ RO 77-10:on 770321 & 22,pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Influent W/Ph Slightly Lower than Normal.Plant Neutralized & Returned to Normal Operation | Grab sample |
ML20086F325 | 22 February 1977 | Environ RO 77-7:pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Influent W/Ph Slightly Lower than Normal.Plant Neutralized & Returned to Normal Operation | Grab sample |
ML20086F326 | 2 May 1977 | Environ RO 77-12:on 770422,pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Influent W/Ph Slightly Lower than Normal.Plant Neutralized & Returned to Normal Operation | Grab sample |
ML20086F380 | 1 February 1977 | Environ RO 77-5:on 770123,pH of Sewage Plant Effluent Exceeded ETS Limit.Caused by Influent W/Ph Slightly Lower than Normal.Plant Neutralized & Returned to Normal Operation | Grab sample |
ML20086F381 | 27 December 1976 | Environ RO 76-45:on 761217,chemical Usage for First 6 Months of 1976 Exceeded Twice Estimated Yearly Usage.Caused by High Demineralizer Water Consumption Due to High Makeup to Auxiliary Boilers & Increased Makeup to Main Units | |
ML20086F412 | 9 December 1976 | Revised RO Re Plant Iodine & Particulate Release Rate Exceeding 4% of Tech Spec 3.8.C.2 Averaged Over Fourth Quarter 1976.Caused by Leaks in Reactor Water Cleanup Sys. Leaks Repaired & Equipment Modified to Reduce Leakage | |
ML20086F418 | 9 December 1976 | RO Re Plant Iodine & Particulate Release Rate Exceeding 4% of Tech Spec 3.8.C.2 Averaged Over Fourth Calendar Quarter 1976.Caused by Leaks in Reactor Water Cleanup Sys.Leaks Repaired & Equipment Modified to Reduce Leakage | |
ML20086F426 | 16 June 1977 | Environ RO 77-14:on 770606 & 08,ph for Settling Basin Effluent Exceeded ETS Limit.Cause Not Identified.Settling Basin Isolated & Neutralized.Ph Checked & Sys Returned to Normal Operation | Grab sample |