 Issue dateTitleTopic
ML20059H77217 January 1994Part 21 Rept Re Virginia Power Notifying Fairbands Morse Via Failure Analysis Rept NESML-Q-058 of Defective Air Start Distributor cam,16104412
ML20064J5808 November 1982Part 21 Rept Re Matl That May Not Be in Compliance W/ 10CFR50,App B,Section Viii Requirements.Matl Supplied to Ne Public Power District & Omaha Public Power District.Qa Depts Contacted Re Resolution of Nonconformance Situation
ML20065C72410 September 1982Part 21 Rept Re Contaminants in Snubber Hydraulic Fluid. Initially Reported on 820323.Program Developed in Which Fluid Reservoirs Completely Flushed Prior to Filling W/Fresh Fluid.Containment Snubbers to Be Rebuilt by 821001
ML20072A7698 August 1994Interim Part 21 Rept 2 Re Weak Link Analysis for Movs.No Evidence to Support Fact of Erroneous Data Discovered. Investigation ContinuingWeak link
ML20076M83228 October 1994Submits Followup to 940516 Part 21 Rept Informing of Investigation to Determine Data Supplied in mid-80 Used by Nuclear Utilities to Set Torque Switches in MOVWeak link
ML20078F58427 January 1995Part 21 Rept Re Vendor Using Incorrect Acceptance Criteria on Qualification Test Rept & Acceptance Criteria Used Not Not Met by Cvts.Vendor Continues to Seek Resolution of Matter
ML20079L49129 October 1991Part 21 & Deficiency Rept 158 Re Potential Defect in Component of DSRV-16-4 Standby Diesel Generator Sys. Drawing Rev to Increase Gear Tooth Hardness Completed. Recommended Corrective Actions for Sites Listed
ML20080G32730 January 1995Part 21 Rept Re Furnished Commercial grade/non-safety Related Studs,Nuts & Washers for Use on safety-related Crystal River 5th Yr post-tension Surveillance ProgramCommercial Grade Dedication
Commercial Grade
ML20085J41110 October 1983Part 21 Rept Re Apparent Increase in Scope of Fraudulent & Substandard Activities by Unscrupulous Suppliers.Reliability Emphasized
ML20094F52118 February 1992Part 21 Rept Re Defect in Amot Control Corp Safety Trip Valves for Use in Edgs.Defective Overspeed Trip Valve Removed from DG 1.Replacement & Existing Amot Overspeed Trip Valve on DG 2 Inspected & Determined Not to Contain Defect
ML20094J4682 March 1992Part 21 Rept Re Amot Valve (Amot Part 1476B0212A3).Valve Originally Supplied as Part Number 2-05V-153-004 in Overspeed Shutdown Assembly KSV-72-7.Production of Valve Discontinued & Advises That Alternate Assemble Available
ML20101M89230 June 1992Initial Part 21 Rept Re non-segregated Phase Electrical Bus Duct Mfg in 1972.Initially Reported on 920427.Detailed Calculations Being Done by FPC to Evaluate Momentary Fault Current Against Supplied Ratings of All Bus Sections
ML20101N8445 April 1996Interim Part 21 Rept Re Potential Safety Concern on Matl for Fabrication of Permanent Canal Seal Plate.Licensee Will Provide Final Rept to NRC in Approx Six Months Upon Completion of Evaluation of WeldsCommercial Grade
ML20118B21923 September 1992Suppl to Part 21 Rept Re Potential Deviation in Some Bailey Controls Co 88 Series Modules,Transmitted Via .One Module Found Incapable of Reaching 100% Output at Max Rated Load.Recommends That Circuit Board Assemblies Be Inspected
ML20118B43911 September 1992Part 21 Rept Re Degradation in Abb Type 27N Undervoltage Relays Used in Electrical Switchgear.Recommends That Users Review Applications Requiring Exposures Greater than 1E03 Rads TID W/Time Delay Function Option
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20126B04217 December 1992Final Part 21 Rept Re Potential Problem W/Steel Cylinder Heads.Initially Reported on 921125.Caused by Inadequate Cast Wall Thickness at 3/4-inch-10 Bolt Hole.Stud at Location Indicated on Encl Sketch Should Be RemovedLoctite
ML20126C6905 June 1985Part 21 Rept Re Generator Failure.Concurs W/Encl Louis Allis That Interpolar Connectors Be Removed
ML20127H23015 January 1993Part 21 Rept Re Potential Defeat in Component of Dsrv & Dsr Enterprise Standby DG Sys.Starting Air Distributor Housing Assemblies Installed as Replacement Parts at Listed Sites
ML20127H54117 May 1985Part 21 Rept Re Potential Defect in Engine Generator Control Panels of Dsr or DSRV-16 Standby Diesel Generator.Review of Generator Control Panel Installation by Each Facility Recommended
ML20127N06213 May 1985Part 21 Rept Re Incorrect Short Time Delay Band Lever Inadequately Installed in Low Voltage K-line Circuit Breaker Electromechanical Overcurrent Trip Device.Visual Insp to Determine If Correct Lever Installed Recommended
ML20127P58623 November 1992Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl
ML20132B0263 September 1985Part 21 Rept Re Possibility of Engine Ingestion of Unwelded Part in American Air Filter Standby Diesel Generator Intake Silencer.Immediate Hold Should Be Placed on Diesel Engines/Intake Silencers Not Yet in Svc
ML20133E8008 January 1997Deficiency Rept Re Nonconformance Related to Masterflow 713 Grout,Which Master Builders,Inc Has Supplied as Nuclear SR Product to 18 Npps.Cause Unknown.Requests That Listed Info Be Provided to Gain Insight as to Scope & Possible Cause
ML20134B23024 January 1997Final Part 21 Rept Re Potential Safety Concern on Matl Used for Fabrication of Permanent Canal Seal Plate.Correpondence W/Fabricator & Matl Supplier Documents Tig Automated Welding Process Used to Fabricate Angle PiecesCommercial Grade
ML20134M77129 August 1985Part 21 Rept Re Potential for Four Valves in HPI Lines to Become Inoperable If Postulated Single Failure Resulted in Total Loss of Cable Tray.Six Cables for Two Valves in HPI Line Removed from Tray & Routed Through Separate Conduits
ML20136A9398 November 1985Part 21 & Deficiency Rept Re Rev B to Rosemont Instruction Manual 4302 Not Addressing Zero Shift Due to Process Pressure in Model 1153 Alphaline Nuclear Pressure Transmitter
ML20136B0228 November 1985Part 21 & Deficiency Rept Re Unreliable Porthole Oil Level Gauge for Auxiliary Feedwater Pumps Supplied by B&W.Metal Insert Behind Sight Glass Trapped Oil Causing False Level Indication.Metal Insert Removed
ML20137G62625 March 1997Svcs Part 21 Rept Re Emergency Generators Installed at Zion Station Which Developed Significant Drop in Crankcase Lube Oil Level.Caused by Crack in Liner Wall,Allowing Jacket Water to Enter ChamberFinite Element Analysis
ML20137X38927 February 1986Part 21 Rept Re Possible Defect in Model KMG-HRH Noble Gas Radiation Monitor W/Enhanced Detector Model KDGM-HR. Initially Reported on 860222.Vendor Will Request Utils for Listed Plants to Determine If Monitors Defective
ML20140A52819 December 1985Part 21 Rept Forwarding Ltr Sent to Customers Re Check Valves Missing Lock Welds on Hinge Supports or Hinge Support Capscrews,Per 851121 Request.List of Customers Receiving Ltr Also Encl
ML20140A96629 May 1997Part 21 Rept Re Ksv Emergency Diesel Generator Power Piston Failure.Caused by Jacket Water in Combustion Chamber. Recommends That Users Verify That Crown Thickness at Valve Cutout Be 100 MinimumFinite Element Analysis
ML20140G4481 May 1997Part 21 Rept Re Potential Defect in Component of Dsrv & Dsr Enterprise Standby Diesel Generator Sys.Recommends That Springs Be Inspected on Periodic Basis,Such as During Refueling Outages
ML20151J5007 April 1988Part 21 & Deficiency Rept 88-02 Re Improper Mounting of Armature Button on Undervoltage Device Armature.Maint Procedure for CRD Trip Breaker Revised to Include Checks for Defects Discovered W/Undervoltage Device
ML20153B28122 February 1988Part 21 Rept Re Defect in Operation of Gas Monitors Using Fixed Filters.Initially Reported on 880212.Caused by Error in Software for Monitors.Vendor Testing Mod to Software & in Interim Recommends Changing Filters Every 48 H
ML20153B61929 April 1988Part 21 Rept Re Potential Defect in Component of Dsr or Dsrv Standby Diesel Generators Supplied to Utils.Recommends Return of Subj Components in Onsite Warehouse Storage & Suggests Surveillance of Devices Already Installed
ML20154A8789 May 1988Rev 1 to Part 21 & Deficiency Rept 88-02 Re Improper Mounting of Armature Button on Undervoltage Device Armature. CRD Trip Breaker Removed from Svc & Placed in QC Quarantine & Maint Procedure Revised for Armature Defect
ML20154J41012 May 1988Addendum 1 to Supplemental Part 21 Rept 145 Re Potential Problem w/F-573-156 Pressure Sensor/Lube Oil Trip.Initially Reported on 880429.Addl 1-1/8-inch Diameter W/Deep Counterbone in Pressure Head Added to Activate Valve
ML20154N34310 March 1986Initial Part 21 Rept 135 Re Potential Problem W/Lube Oil Sump Tank Foot Valve of Dsrv Standby Diesel Generator for Facilities.Cause Not Determined.Recommends Utils Inspect Condition of Foot Valve Liners & Notify Tdi of Findings
ML20155A02827 March 1986Part 21 Rept Re Crystal River Shaft Fracture.Addl Info Will Be Submitted When Failure Analyses & Recommendations Completed.W/O Stated Encl
ML20155C40916 May 1988Part 21 Rept 88-03 Re Potential Problem W/Gems Sensors Model 63328A Modular Receivers.Modular Receivers Qualified Toggle Switch InstalledCommercial Grade Dedication
ML20195D21727 May 1986Rev 1 to Part 21 Rept Re Dowel Displacement on Connecting Rod Bearings Purchased During Nov 1985 - Apr 1986.Initially Reported on 860421.Rod Bearings Will Be Inspected Dimensionally.Further Info Forthcoming
ML20196D62810 February 1988Part 21 Rept Re Potential Defect in Certain Model RTF-480/120-30 Ac Line Regulating Transformers Involving Nuisance Tripping of 100 Ampere Ac Input Circuit Breaker When Initializing Unit.Breaker Should Be Replaced
ML20198C4986 November 1985Part 21 Rept Re Potential Defect in Dsr or Dsrv Standby Diesel Generator Intake & Exhaust Valve Springs Mfg by Betts Spring Co.Users Recommended to Inspect Engines for Broken Springs & Identify Original Mfg
ML20203D02214 July 1986Part 21 Rept Re Air Monitoring Sys Probes Exhibiting Blue Tip Rather than Normal White Tip & Insensitive to Chlorine. Caused by Improper Handling/Storage.Advisory Bulletin Encl. Item Not Reportable Per Part 21
ML20205B84030 July 1986Part 21 Rept Re Chattering of Wilmar Electronics Underpower monitor-type Relay Circuit Boards,Model 21-171.Caused by Overheated Components,Damaged Circuit Boards & Bad Solder Connections.Defective Relay Replaced
ML20205C68917 September 1985Part 21 Rept Re Potential Defect in Centerline,Inc Lube Oil Check Valves of Dsr Standby Diesel Generator Which Could Result in Engine Nonavailability.Valve Seat Matl Will Be Changed to Buna N.List of Tdi Part 21 Repts Encl
ML20205F32110 October 1988Part 21 Rept Re Potential Deviation from Tech Spec Concerning Ry Indicators Due to Operating Temp Effect on Analog Meter Movement.Initially Reported on 881006.Customers Verbally Notified on 881006-07
ML20205R58531 March 1987Part 21 & Deficiency Rept 139 Re Potential Defect in Engine Control Panel Shutdown Circuitry of Dsr & Dsrv Standby Diesel Generator.Corrective Action at Vogtle Already Implemented.Mfg Will Work W/Smud to Implement Mods
ML20206Q6496 April 1987Part 21 Rept 87-05 Re Possible Loss or Degradation of Reactor Protection Sys Channels a & B or C & D Due to Common Amplifier Failure.Initially Reported on 870403.Caused by B&W Design Error.Isolation Amplifiers Will Be Used