Part 21 & Deficiency Rept 139 Re Potential Defect in Engine Control Panel Shutdown Circuitry of Dsr & Dsrv Standby Diesel Generator.Corrective Action at Vogtle Already Implemented.Mfg Will Work W/Smud to Implement Mods
ML20205R585
Person / Time
Site: Vogtle, Rancho Seco, 05000000
Issue date: 03/31/1987
From: Guntrum B
IMO DELAVAL, INC.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-87, REF-PT21-87-063-000 139, PT21-87-063-000, PT21-87-63, NUDOCS 8704060385
Download: ML20205R585 (2)


Text

GOL Did, N){

50-la u-inm peiavei inc.

Enterprime Engine Dht:lon Enterprise Way and 85th Awnue D Oakland. CA 98ti2 P. O. Hox 21til

-115-577-7100 March 31, 1987 Director, Office of Inspection and Enforcement US Nuclear Regulatory Commission Washington, DC 20553 Report #139

Dear Sir,

In accorance with the requirements of Title 10, Chapter 10, Code of Federal Regulbtions, Part 21, IMO Delaval Inc.

hereby notifies the Commission of a potential defect in a component of a DSR and DSRV Standby Diesel Generator.

There exists a potential problem in the engine control panel shutdown circuitry.

IMO Delaval has supplied USR and DSRV engines with this potential defect to the iollowing sites:

UTILITY SITE SERIAL __NO.

MODEL Georgia Power Vogtle 76021/24 DSRV-16-4 SHUD Rancho Seco 01015/16 DSR-48 As engine speed decreasen during an engine stop sequence, the low pressure lube oil sensors trip when the lube oil system pressure decreases to 30 pai.

This condition in transmitted to the 2 out of 3 logic board located in the engine control panel which in turn operates / latches the emergency stop relay.

After the emergency stop relay is latched, the diesel engine cannot be started until the emergency stop relay is manually reset.

While this potential problem is reported at Georgia Power Vogtic Plant, it is our understanding that Georgia Power has already implemented corrective action.

1HO Delaval will be working with SHUD to identify and implement control circuitry modifications.

Since action is required by others, however, we cannot estimate when corrective action will be completed.

070406030D 070331 PDR ADOCK 05000312 8

PDH I?

' O k

s.

Page 2 March 31, 1987 US Nuclear Regulatory Commission A copy of this letter will be sent to the affected sites as indicated by the cc list.

Sincerely,

_ yw _ _ _..,.

Bruce C. Guntrum Manager, Quality Assuranco UCG/dfa cc:

Sacramento Municipal Utilit.y District P.O.

Box 15830 Sacramento, CA 95013 Attn:

Mr. Cranston Nuclear Engineering Dept., H.S. 200 J.R. Deal Purchaning Dept., H.S. 50 Georgia Power Company Plant Vogtle P.O.

Box 202 l

Waynenboro, Georgia 30830 Attn:

Mr. Georno Bockhold, Jr.

l Plant Manager l

\\