ML20064J580

From kanterella
Jump to navigation Jump to search

Part 21 Rept Re Matl That May Not Be in Compliance W/ 10CFR50,App B,Section Viii Requirements.Matl Supplied to Ne Public Power District & Omaha Public Power District.Qa Depts Contacted Re Resolution of Nonconformance Situation
ML20064J580
Person / Time
Site: Cooper, Fort Calhoun, 05000000
Issue date: 11/08/1982
From: Owen R
PAXTON CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
REF-PT21-82-741-000 PT21-82-741, PT21-82-741-000, TAC-07934, TAC-7934, NUDOCS 8301180123
Download: ML20064J580 (1)


Text

-

TELEPHONE 347 5500 STROCTORAL ITEEL FA00lCAil0E Paxton & Vierling Steel Co. """'"*"" *""

E S iA B L i S H ED 1 8 85 P. O BO4 1085 Omaha, Nebraska 6sio November 8, 1982 United States Nuclear Regulatory 3. - r l-Commission Region No. 4 r

i

{V'47 \ %k'!l g,

l\yO

611 Ry laza Drive O ~$ O / 3'j 4 j Arlington, Texas 76011 Attention: Regional Administrator John Collins x]-

Re: Material Supplied Under Regulation 10CFR50, Appendix B Gentlemen:

This letter is to advise you that some material supplied by Paxton & Vierling Steel Co. may not be in com-pliance with all of the requirements of 10CFR50, Appendix B, Section VIII and 10CFR21, various sections.

The material in question has been supplied to Nebraska Public Power District, Brownville, Nebraska plant and Omaha Public Power District, Ft. Calhoun, Nebraska plant.

We have been and continue to remain in constant contact with the Quality Assurance departments of both NPPD and OPPD to resolve this nonconformance situation.

Very truly yours, PAXTON & VIERLING STEEL CO.

By ExeNutiveVicePresident Q RE0 wen /wa cc: Swarr, May, Smith,

\1 Andersen, & Jensen D.DuBois, USNRC NPPD, Brownville, Nebr.

0301180123 821109 PDR ADOCK 05000205 S PDR