Interim Part 21/deficiency Rept Re Low Pressure Safety Injection & CS Pump Motors W/Defective Welds & Oil Leaks. Initially Reported on 830629.Due to Extensive Investigation, Final Rept Will Not Be Submitted Until 840206
ML20086J939
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 01/05/1984
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Bishop T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
REF-PT21-84-340-000 ANPP-28559-BSK, DER-83-40, PT21-84-340, PT21-84-340-000, NUDOCS 8401260035
Download: ML20086J939 (2)