Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML24107A6972024-04-12012 April 2024 Engine Systems, Inc Part 21 Report Re EMD Cylinder Liner Water Leak ML22301A1742022-10-28028 October 2022 Global Nuclear Fuel Americas, LLC (GNF) - Part 21 60-Day Interim Report Notification: GNF3 Raised Water Rod (SC-22-04 Rt) ML21225A0812021-08-0404 August 2021 Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML21014A2342020-12-0707 December 2020 Fourth Interim Notification Per 10 CFR Part 21 Re Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML20304A1612020-10-14014 October 2020 Lake Engineering Co., Degraded Snubber SF1154 Hydraulic Fluid Batch No. 16DLVS852 Final Report Per 10 CFR Part 21 ML20097B6912020-03-20020 March 2020 Second Interim Notification Per 10 CFR Part 21: Degraded Snubber SF1154 Hydraulic Fluid Batch No. 16DLVS852 ML20108F5302020-03-20020 March 2020 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0129, Rev. 0, Test Stand Deficiency - EMD Fuel Injectors P/N H40084720 ML20049A0752020-02-11011 February 2020 C&D Technologies, Inc. -10 CFR Part 21 Evaluation Regarding Container Failure in KCR-07 Batteries ML19347A4262019-12-10010 December 2019 General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) ML19002A2042018-12-21021 December 2018 to Engine Systems, Inc., Part 21 Report Re Emd Fuel and Soakback Pumps - Potentially Undertorqued Cover Bolts ML18354A7422018-12-0404 December 2018 Engine Systems, Inc., Submittal of 1OCFR21 Reporting of Defects and Non-Compliance - Report No. 1OCFR21-0123, Rev. 0 - Emo Fuel and Soakback Pumps - Potentially Undertorqued Cover Bolts ML18353A4282018-11-30030 November 2018 Engine Systems, Inc., 10CFR21-0123, Rev. 0, for a 10CFR21 Reportable Condition on Emd Fuel and Soakback Pumps ML18078A5362018-01-31031 January 2018 Crane Nuclear, Inc. - Interim Report for 10 CFR Part 21 Investigation Report Notification of Xomox Plug Valve High Torsional Stress in Stem (Update) ML17194A8252017-07-11011 July 2017 Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections ML17090A4002017-03-24024 March 2017 Part 21 - Failure of Power Supplies to Meet Voltage Stability Specifications ML17086A0222017-03-23023 March 2017 Part 21 - Failure of Power Supplies to Meet Voltage Stability Specifications ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML17039A5692017-02-0303 February 2017 Final Part 21 Report on Defect, Potential for Test Induced Damage 0867F Series Main Steam Safety Relief Valves ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML17026A4132017-01-11011 January 2017 Part 21 - Failure of Power Supplies to Meet Voltage Stability Specifications ML16061A0092016-02-22022 February 2016 Curtiss Wright - Part 21 Notification - Potential Defect in Okonite Tape Splices, Per James A. Fitzpatrick ML16055A1222016-02-22022 February 2016 Curtiss-Wright Corp. - Potential Defect in Okonite Tape Splices, Per James A. Fitzpatrick Nuclear Power Plant ML16039A2692016-02-0303 February 2016 Nutherm International, Inc. - Potential Issue Regarding Incorrect Industrial Irradiation Dose, Per Cooper, Oconee, Fitzpatrick, Point Beach, Brunswick, and Susquehanna ML15357A0412015-12-18018 December 2015 Nutherm International, Inc. - Potential Part 21 Report Involving RTD Transmitter, Per Fitzpatrick ML15187A1722015-06-30030 June 2015 Interim Part 21 Report - Potential Test Induced Defect in 0867F Main Steam Safety Relief Valves ML15134A0172015-05-0101 May 2015 Part 21 Report Regarding Potential Test Induced Defect in a 0867F Main Steam Safety Relief Valves ML15077A4222015-03-17017 March 2015 Curtiss Wright Flow Control Co., Interim Part 21 Report - Potential Test Induced Defect in a 0867F Main Steam Safety Relief Valves ML15022A6502015-01-20020 January 2015 Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification ML14210A0102014-07-23023 July 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve ML14204A7082014-07-23023 July 2014 Enclosure 2, Description of Closure Evaluation, Non-Proprietary Information - Class I (Public) ML14204A7072014-07-23023 July 2014 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV W3F1-2014-0026, Notification of Potential Part 21 Report of Time-Delay Relays Spurious Actuation2014-04-11011 April 2014 Notification of Potential Part 21 Report of Time-Delay Relays Spurious Actuation ML14079A0282014-03-13013 March 2014 Part 21 - Allen Bradley Type 700RTC Relay Spuriously De-Energizing ML13238A2532013-08-21021 August 2013 Notification of Potential Part 21 Report - Foxboro Power Supply Potential Failures Due to Defective the Wraps and Holders ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13127A0122013-05-0303 May 2013 Notification of Potential Interim Part 21 Report of Defect in a Relief Valve Bellows ML13093A1532013-04-0202 April 2013 Part 21 Report - Foxboro Power Supply Potential Failures Due to Defective Tie Wraps and Holders ML13064A0122013-02-25025 February 2013 Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve ML13044A0752013-02-0808 February 2013 Part 21 - Completed Evaluation for Potential Error in Main Steam Line High Flow Calculational Methodology ML13042A0962013-02-0808 February 2013 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Error in Main Steam Line High Flow Calculational Methodology ML12348A1362012-12-13013 December 2012 Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers ML12352A1232012-12-13013 December 2012 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML12347A3082012-12-12012 December 2012 Part 21 60-Day Interim Report Notification: Error in Main Steam Line High Flow Calculational Methodology ML12319A0122012-09-27027 September 2012 Error in Main Steam Line High Flow Calculational Methodology ML12319A0112012-09-27027 September 2012 Part-21 Report - Faulty Master Trip Units, Slave Units, and Resistance Temperature Detectors ML12177A0562012-06-21021 June 2012 Part 21 - Reliability Degradation of Resistors in Trip Units and Readout Assemblies ML12163A1302012-06-0606 June 2012 Part 21 Report - Failure of CRD Collet Retainer Tube/Outer Tube Weld ML12158A4472012-06-0606 June 2012 Part 21 60-Day Interim Report Notification - Closufailure of CRD Collet Retainer Tube/Outer Tube Weld ML12094A3712012-04-0202 April 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12040A2832012-02-0707 February 2012 Notification of Potential Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance 2024-04-12
[Table view] Category:Letter
MONTHYEARML24270A0742024-09-30030 September 2024 Individual Notice of Consideration of Issuance of Amendments to Renewed Facility Operating Licenses, Proposed No Significant Hazards Consideration Determination, & Opportunity for a Hearing (EPID L-2024-LLA-0134) - LTR ML24270A1452024-09-26026 September 2024 Notice of Enforcement Discretion for James A. Fitzpatrick Nuclear Power Plant JAFP-24-0047, License Amendment Request – Temporary Addition to TS 3.3.2.1 Condition C, Control Rod Block Instrumentation to Support Upgrade to Rod Worth Minimizer Software2024-09-25025 September 2024 License Amendment Request – Temporary Addition to TS 3.3.2.1 Condition C, Control Rod Block Instrumentation to Support Upgrade to Rod Worth Minimizer Software JAFP-24-0045, Supplemental Information for License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications2024-09-20020 September 2024 Supplemental Information for License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications IR 05000333/20240112024-09-19019 September 2024 Follow-up to Inspection Procedure 71153 Report 05000333/2024011 and Preliminary White Finding and Apparent Violation JAFP-24-0044, Core Operating Limits Report Cycle 272024-09-16016 September 2024 Core Operating Limits Report Cycle 27 JAFP-24-0043, Revision to Commitment Relating to Resolution of Anchor Darling Double Disc Gate Valve Part 21 Issues2024-09-12012 September 2024 Revision to Commitment Relating to Resolution of Anchor Darling Double Disc Gate Valve Part 21 Issues ML24165A0382024-09-0404 September 2024 Issuance of Amendment No. 356 Update Fuel Handling Accident Analysis 05000333/LER-2024-002, Reactor Protection System Electric Power Monitoring System Trip Caused Primary Containment Isolation2024-09-0404 September 2024 Reactor Protection System Electric Power Monitoring System Trip Caused Primary Containment Isolation IR 05000333/20240052024-08-29029 August 2024 Updated Inspection Plan for James A. Fitzpatrick Nuclear Power Plant (Report 05000333/2024005) 05000333/LER-2024-001, EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket2024-08-21021 August 2024 EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket ML24222A6772024-08-0909 August 2024 Response to Request for Additional Information for Application to Revise Technical Specifications to Adopt TSTF-591-A, Revise Risk Informed Completion Time (RICT) Program Revision 0 and Revise 10 CFR 50.69 License Condition IR 05000333/20240022024-08-0707 August 2024 Integrated Inspection Report 05000333/2024002 JAFP-24-0034, 10 CFR 50.46 Annual Report2024-07-31031 July 2024 10 CFR 50.46 Annual Report ML24208A0492024-07-30030 July 2024 Notice of Consideration of Issuance of Amendments to Facility Operating Licenses and Proposed No Significant Hazards Consideration Determination (Letter) JAFP-24-0036, Supplement to License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2024-07-29029 July 2024 Supplement to License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-24-0033, Response to Request for Information Pertaining to a Licensed Operator Positive Fitness-For-Duty Test2024-07-23023 July 2024 Response to Request for Information Pertaining to a Licensed Operator Positive Fitness-For-Duty Test IR 05000333/20244032024-07-18018 July 2024 Biennial Problem Identification and Resolution Inspection Report 05000333/2024403 (Cover Letter Only) IR 05000333/20244012024-07-15015 July 2024 Security Baseline Inspection 05000333/2024401 RS-24-070, Independent Spent Fuel Storage Installation, Nine Mile Point, Units 1 and 2, Quad Cities, Units 1 and 2, R. E. Ginna - Nuclear Radiological Emergency Plan Document Revisions2024-07-12012 July 2024 Independent Spent Fuel Storage Installation, Nine Mile Point, Units 1 and 2, Quad Cities, Units 1 and 2, R. E. Ginna - Nuclear Radiological Emergency Plan Document Revisions ML24190A1932024-07-0909 July 2024 Correction Letter of Amendment No. 355 Revise Technical Specifications Section 3.4.3.1, Safety Relief Valves Setpoint Lower Tolerance IR 05000333/20240102024-07-0808 July 2024 Commercial Grade Dedication Inspection Report 05000333/2024010 ML24184A1662024-07-0303 July 2024 Senior Reactor and Reactor Operator Initial License Examinations ML24136A1162024-06-26026 June 2024 Issuance of Amendment No. 355 Revise Technical Specifications Section 3.4.3.1, Safety Relief Valves Setpoint Lower Tolerance ML24176A2412024-06-24024 June 2024 Licensed Operator Positive Fitness-for-Duty Test JAFP-24-0027, EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket2024-06-24024 June 2024 EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket RS-24-061, Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2024-01, Preparation and Scheduling of Operator Licensing Examinations2024-06-14014 June 2024 Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2024-01, Preparation and Scheduling of Operator Licensing Examinations JAFP-24-0026, Supplement to License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (Srvs) Setpoint Lower Tolerance2024-06-12012 June 2024 Supplement to License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (Srvs) Setpoint Lower Tolerance ML24079A0762024-05-23023 May 2024 Issuance of Amendments to Adopt TSTF 264 JAFP-24-0023, 2023 Annual Radiological Environmental Operating Report2024-05-0909 May 2024 2023 Annual Radiological Environmental Operating Report IR 05000333/20240012024-05-0909 May 2024 Integrated Inspection Report 05000333/2024001 RS-24-041, Alternative Request to Utilize Code Case OMN-32, Alternative Requirements for Range and Accuracy of Pressure, Flow, and Differential Pressure Instruments Used in Pump Tests2024-04-30030 April 2024 Alternative Request to Utilize Code Case OMN-32, Alternative Requirements for Range and Accuracy of Pressure, Flow, and Differential Pressure Instruments Used in Pump Tests JAFP-24-0020, 2023 Annual Radioactive Effluent Release Report2024-04-25025 April 2024 2023 Annual Radioactive Effluent Release Report JAFP-24-0019, 2023 REIRS Transmittal of NRC Form 52024-04-18018 April 2024 2023 REIRS Transmittal of NRC Form 5 ML24106A0152024-04-15015 April 2024 Request for Withholding Information from Public Disclosure Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling ML24103A2042024-04-12012 April 2024 Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-591-A, Revise Risk Informed Completion Time (RICT) Program Revision 0 and Revise 10 CFR 50.69 License Condition ML24107A6972024-04-12012 April 2024 Engine Systems, Inc Part 21 Report Re EMD Cylinder Liner Water Leak RS-24-002, Constellation Energy Generation, LLC - Annual Property Insurance Status Report2024-04-0101 April 2024 Constellation Energy Generation, LLC - Annual Property Insurance Status Report ML24068A0532024-03-28028 March 2024 Issuance of Amendment No. 354 Revise Technical Specifications Section 3.3.1.2, Source Range Monitors Instrumentation JAFP-24-0014, Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2024-03-25025 March 2024 Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-24-0010, Response to Request for Additional Information for License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (S/Rvs) Setpoint Lower Tolerance2024-02-29029 February 2024 Response to Request for Additional Information for License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (S/Rvs) Setpoint Lower Tolerance IR 05000333/20230062024-02-28028 February 2024 Annual Assessment Letter for James A. FitzPatrick Nuclear Power Plant (Report 05000333/2023006) JAFP-24-0009, Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2024-02-28028 February 2024 Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis IR 05000333/20230042024-02-0707 February 2024 Integrated Inspection Report 05000333/2023004 and Independent Spent Fuel Storage Installation Inspection Report 07200012/2023001 ML24037A0102024-02-0606 February 2024 Requalification Program Inspection ML24018A0012024-01-18018 January 2024 Notification of Commercial Grade Dedication Inspection (05000333/2024010) and Request for Information ML24004A2302024-01-0808 January 2024 Project Manager Reassignment ML23356A0832024-01-0404 January 2024 Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0058 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML23278A1292023-12-14014 December 2023 Units 1 & 2; Limerick, Units 1 & 2; Nine Mile Point, Units 1 & 2; and Peach Bottom, Units 2 & 3 -Revision to Approved Alternatives to Use Boiling Water Reactor Vessel and Internals Project Guidelines JAFP-23-0065, License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications2023-12-14014 December 2023 License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications 2024-09-04
[Table view] |
Text
02/22/2016 U.S. Nuclear ReEulatorv Commission Operations Center Event Report Paee 1 022/06 .. Ncla . a.r .. omiso prain ene vn Reoriar Part 21 (PAR) Event# 51674 Rep Org: CURTISS WRIGHT NUCLEAR DIVISION Notification Date I Time: 01/22/2016 14:09 (EST)
Supplier: CURTISS WRIGHT NUCLEAR DIVISION Event Date / Time: 01/21/2016 (CST)
Last Modification: 02/22/2016 Region: 1 Docket #:
City: HUNTSVILLE Agreement State: Yes county: License #:
State: AL NRC Notified by: SAMUEL BLEDSOE Notifications: HAROLD GRAY R1DO HQ Ops Officer: HOWIE CROUCH PART 21/50.55 REACTORS EMAIL Emergency Class: NON EMERGENCY 10 CFR Section:
21 .21 (d)(3)(i) DEFECTS AND NONCOMPLIANCE PART 21 NOTIFICATION - POTENTIAL DEFECT IN OKONITE TAPE SPLICES The following information was obtained from Curtiss-Wright Nuclear Division via fax and email:
"This letter is issued to provide initial notification of a potential defect in Okonite Tape Splices. The potential defect is inadequate radiation testing performed by Steris/Isomedix.
"In~response to NRC Information Notice 2015-12: 'Unaccounted for Error Terms Associated with the Irradiation Testing and Environmental Qualification of Important-to-Safety Components,' an investigation was performed to determine if products had radiation testing performed by Steris/Isomedix, and any impact. This investigation commenced on November 25, 2015.
"It was determined on January 21, 2016 that the qualification of Okonite Tape Splices is affected by the unaccounted for error terms discussed in Information Notice 2015-12. This product has only been provided to James A. FitzPatrick Nuclear Power Plant. This customer will be notified today.
"As a corrective action, Qualification Report PEI-TR-842900-1 will be revised to decrease the Total Integrated Dose (TID) reported by 9.6% based upon the guidance of Information Notice 2015-012. This revision will be provided to James A. FitzPatrick Nuclear Power Plant within 30 days of this notification. Notification will be provided when this corrective action is complete.
"If additional information is required, please contact me by the methods provided below or Quality Assurance Manager Tony Gill: 256-426-4558, tgill@curtisswright.com."
- ** UPDATE FROM SAMUEL BLEDSOE TO VINCE KLCO VIA FACSIMILE ON 2/22/2016 AT 1434 EDT **
- 02/22/2016 U.S. Nuclear Regulatory Commission Operations Center Event Report Pa*e 2 022/06U..Ncer. tr ... Cmiso Oeain Cne vn Reor ai "February 22, 2016 "To whom it may concern:
"On January 22, 2016, Curtiss-Wright Nuclear issued an initial notification letter to the Nuclear Regulatory Commission and customer James A. FitzPatrick Nuclear Power Plant concerning a potential defect in Okonite Tape Splices. The potential defect was inadequate radiation testing performed by Steris/Isomedix. As a corrective action, Qualification Report PEI-TR-842900-1 has been revised to decrease the Total Integrated Dose (TID) reported by 9.6% based upon the guidance of NRC Information Notice 2015-012: 'Unaccounted for Error Terms Associated with the Irradiation Testing and Environmental Qualification of Important-to-Safety Components.' As of this date, Qualification Report PEI-TR-842900-1, Revision C has been provided to James A. FitzPatrick Nuclear Power Plant. This letter provides the final status and closeout of the above referenced 10CFR21 notification. If you require additional details or would like to discuss further, please contact me by the methods provided below or Quality Assurance Manager Tony Gill: 256-426-4558, tgill@curtisswright.com.
"Sincerely, Samuel Bledsoe Engineering Manager "Nuclear Division Curtiss-Wright 125 West Park Loop, Huntsville, AL 35806 T: 256.924.74481 M: 256.690.78521 F: 256.722.8533" Notified R1 DO (Ferdas) and Part 21 Group via email.
Feb 22 2016 14:34:14 8553856216 ->
- USSNCSme H*C lesePg Samuel Bledsoe Page B81 8 Fax Cover Sheet To:
Fax Nlumber: 3018165151
Subject:
Part 21 Closeout From: "Bledsoe, Samuel" csbledsoe~curtisswright.com>
Faxif: 855-305-6216 Date: 02/22/16 02:31:58 PM Total Pages: 3 including this cover page Memo: The attached letter provides the final status and closeout of a Pant 21 Notification (re f.
NRC Event Notification # 51674).
Thank you, Samuel Bledsoe Engineering Manager Nuclear Division Curtiss-Wright 125 West Park Loop, Huntsville, AL 35806 T: 256.924.7448 j M: 256.690.7852 I F: 256.722.8533 sbledsoe~curtisswrig ht~com I www.curtisswright.com/Nuclea rDivision This e-mail and any files transmitted with it are proprietary and intended solely for the use of the i individual or entity to whom they are addressed. If you have reason to believe that you have receivedE this e-mail in error, please notifyr the sender and destroy this email and any attached files. Please notei that any views or opinions presented in this e-mail are solely those of the author and do not necessarily represent those of the Curtiss-Wright Corporation or any of its subsidiaries. Documents attached hereto may contain technology subject to government export regulations. Recipient is solely responsible for:
ensuring that any re-export, transfer or disclosure of this information is in accordance with applicable:
government export regulations. The recipient should check this e-mail and any attachments for the presence of viruses. Curtiss-Wright Corporation and its subsidiaries accept no liability for any damage caused by any virus transmitted by this e-mail.
Feb 22 20Th 14:34:31 855305621h -*>15NlESme US-flRC ldsePg Samuel Bl*dso* 0 Poge 882 This electronic communication, including attachments, is for the exclusive use of addressee and may contain proprietary, confidential and/or privileged information. If you are not the intended recipient, any use, copying, disclosure, dissemination or distribution is strictly prohibited. If you are not the intended recipient, please notify sender immediately by phone, destroy this communication and all.
copies.
Feb 22 2016 14:34:38 8553856216->U -> US HRCRSaulBesePg80 Samuel Bledsne Page 8B3
- ,*Nuclear Division West Park Loop NW
- THuntsville, AL 35806 T: 256.722.8500 I F: 258.722.8533 www.curtisswrfght~com/N uclearDivision (File No.: CWN1OCFR21-2O15-04)
February 22, 2016 To whom it may concern:
On January 22, 2016, Curtiss-Wright Nuclear issued an initial notification letter to the Nuclear Regulatory Commission and customer James A. FitzPatrick Nuclear Power Plant concerning a potential defect in Okonite Tape Splices. The potential defect was inadequate radiation tasting performed by Steris/Isomedix.
As a corrective action, Qualification Report PEI-TR-842900-1 has been revised to decrease the Total Integrated Dose (TID) reported by 9.6% based upon the guidance of NRC Information Notice 2015-012 : "Unaccounted for Error Terms Associated with the Irradiation Testing and Environmental Qualification of Important-to-Safety Components." As of this date, Qualification Report PEI-TR-842900-1, Revision C has been provided to James A. FitzPatrick Nuclear Power Plant.
This letter provides the final status and closeout of the above referenced 10OCFR2I notification.
It you require additional details or would like to discuss further, please contact me by the methods provided below or Quality Assurance Manager Tony Gill: 256-426-4558, tglLcrtswiht.com, Sincerely, Samuel Bledsoe Engineering Manager Nuclear Division C urtisa-Wright 125 West Park Loop, Huntsville, AL 35806 T: 256.924.7448 M: 256.690.7852 I F: 256.722.8533
02/22/2016 U.S. Nuclear ReEulatorv Commission Operations Center Event Report Paee 1 022/06 .. Ncla . a.r .. omiso prain ene vn Reoriar Part 21 (PAR) Event# 51674 Rep Org: CURTISS WRIGHT NUCLEAR DIVISION Notification Date I Time: 01/22/2016 14:09 (EST)
Supplier: CURTISS WRIGHT NUCLEAR DIVISION Event Date / Time: 01/21/2016 (CST)
Last Modification: 02/22/2016 Region: 1 Docket #:
City: HUNTSVILLE Agreement State: Yes county: License #:
State: AL NRC Notified by: SAMUEL BLEDSOE Notifications: HAROLD GRAY R1DO HQ Ops Officer: HOWIE CROUCH PART 21/50.55 REACTORS EMAIL Emergency Class: NON EMERGENCY 10 CFR Section:
21 .21 (d)(3)(i) DEFECTS AND NONCOMPLIANCE PART 21 NOTIFICATION - POTENTIAL DEFECT IN OKONITE TAPE SPLICES The following information was obtained from Curtiss-Wright Nuclear Division via fax and email:
"This letter is issued to provide initial notification of a potential defect in Okonite Tape Splices. The potential defect is inadequate radiation testing performed by Steris/Isomedix.
"In~response to NRC Information Notice 2015-12: 'Unaccounted for Error Terms Associated with the Irradiation Testing and Environmental Qualification of Important-to-Safety Components,' an investigation was performed to determine if products had radiation testing performed by Steris/Isomedix, and any impact. This investigation commenced on November 25, 2015.
"It was determined on January 21, 2016 that the qualification of Okonite Tape Splices is affected by the unaccounted for error terms discussed in Information Notice 2015-12. This product has only been provided to James A. FitzPatrick Nuclear Power Plant. This customer will be notified today.
"As a corrective action, Qualification Report PEI-TR-842900-1 will be revised to decrease the Total Integrated Dose (TID) reported by 9.6% based upon the guidance of Information Notice 2015-012. This revision will be provided to James A. FitzPatrick Nuclear Power Plant within 30 days of this notification. Notification will be provided when this corrective action is complete.
"If additional information is required, please contact me by the methods provided below or Quality Assurance Manager Tony Gill: 256-426-4558, tgill@curtisswright.com."
- ** UPDATE FROM SAMUEL BLEDSOE TO VINCE KLCO VIA FACSIMILE ON 2/22/2016 AT 1434 EDT **
- 02/22/2016 U.S. Nuclear Regulatory Commission Operations Center Event Report Pa*e 2 022/06U..Ncer. tr ... Cmiso Oeain Cne vn Reor ai "February 22, 2016 "To whom it may concern:
"On January 22, 2016, Curtiss-Wright Nuclear issued an initial notification letter to the Nuclear Regulatory Commission and customer James A. FitzPatrick Nuclear Power Plant concerning a potential defect in Okonite Tape Splices. The potential defect was inadequate radiation testing performed by Steris/Isomedix. As a corrective action, Qualification Report PEI-TR-842900-1 has been revised to decrease the Total Integrated Dose (TID) reported by 9.6% based upon the guidance of NRC Information Notice 2015-012: 'Unaccounted for Error Terms Associated with the Irradiation Testing and Environmental Qualification of Important-to-Safety Components.' As of this date, Qualification Report PEI-TR-842900-1, Revision C has been provided to James A. FitzPatrick Nuclear Power Plant. This letter provides the final status and closeout of the above referenced 10CFR21 notification. If you require additional details or would like to discuss further, please contact me by the methods provided below or Quality Assurance Manager Tony Gill: 256-426-4558, tgill@curtisswright.com.
"Sincerely, Samuel Bledsoe Engineering Manager "Nuclear Division Curtiss-Wright 125 West Park Loop, Huntsville, AL 35806 T: 256.924.74481 M: 256.690.78521 F: 256.722.8533" Notified R1 DO (Ferdas) and Part 21 Group via email.
Feb 22 2016 14:34:14 8553856216 ->
- USSNCSme H*C lesePg Samuel Bledsoe Page B81 8 Fax Cover Sheet To:
Fax Nlumber: 3018165151
Subject:
Part 21 Closeout From: "Bledsoe, Samuel" csbledsoe~curtisswright.com>
Faxif: 855-305-6216 Date: 02/22/16 02:31:58 PM Total Pages: 3 including this cover page Memo: The attached letter provides the final status and closeout of a Pant 21 Notification (re f.
NRC Event Notification # 51674).
Thank you, Samuel Bledsoe Engineering Manager Nuclear Division Curtiss-Wright 125 West Park Loop, Huntsville, AL 35806 T: 256.924.7448 j M: 256.690.7852 I F: 256.722.8533 sbledsoe~curtisswrig ht~com I www.curtisswright.com/Nuclea rDivision This e-mail and any files transmitted with it are proprietary and intended solely for the use of the i individual or entity to whom they are addressed. If you have reason to believe that you have receivedE this e-mail in error, please notifyr the sender and destroy this email and any attached files. Please notei that any views or opinions presented in this e-mail are solely those of the author and do not necessarily represent those of the Curtiss-Wright Corporation or any of its subsidiaries. Documents attached hereto may contain technology subject to government export regulations. Recipient is solely responsible for:
ensuring that any re-export, transfer or disclosure of this information is in accordance with applicable:
government export regulations. The recipient should check this e-mail and any attachments for the presence of viruses. Curtiss-Wright Corporation and its subsidiaries accept no liability for any damage caused by any virus transmitted by this e-mail.
Feb 22 20Th 14:34:31 855305621h -*>15NlESme US-flRC ldsePg Samuel Bl*dso* 0 Poge 882 This electronic communication, including attachments, is for the exclusive use of addressee and may contain proprietary, confidential and/or privileged information. If you are not the intended recipient, any use, copying, disclosure, dissemination or distribution is strictly prohibited. If you are not the intended recipient, please notify sender immediately by phone, destroy this communication and all.
copies.
Feb 22 2016 14:34:38 8553856216->U -> US HRCRSaulBesePg80 Samuel Bledsne Page 8B3
- ,*Nuclear Division West Park Loop NW
- THuntsville, AL 35806 T: 256.722.8500 I F: 258.722.8533 www.curtisswrfght~com/N uclearDivision (File No.: CWN1OCFR21-2O15-04)
February 22, 2016 To whom it may concern:
On January 22, 2016, Curtiss-Wright Nuclear issued an initial notification letter to the Nuclear Regulatory Commission and customer James A. FitzPatrick Nuclear Power Plant concerning a potential defect in Okonite Tape Splices. The potential defect was inadequate radiation tasting performed by Steris/Isomedix.
As a corrective action, Qualification Report PEI-TR-842900-1 has been revised to decrease the Total Integrated Dose (TID) reported by 9.6% based upon the guidance of NRC Information Notice 2015-012 : "Unaccounted for Error Terms Associated with the Irradiation Testing and Environmental Qualification of Important-to-Safety Components." As of this date, Qualification Report PEI-TR-842900-1, Revision C has been provided to James A. FitzPatrick Nuclear Power Plant.
This letter provides the final status and closeout of the above referenced 10OCFR2I notification.
It you require additional details or would like to discuss further, please contact me by the methods provided below or Quality Assurance Manager Tony Gill: 256-426-4558, tglLcrtswiht.com, Sincerely, Samuel Bledsoe Engineering Manager Nuclear Division C urtisa-Wright 125 West Park Loop, Huntsville, AL 35806 T: 256.924.7448 M: 256.690.7852 I F: 256.722.8533