To Engine Systems, Inc., Part 21 Report Re EMD Fuel and Soakback Pumps - Potentially Undertorqued Cover Bolts
ML19002A204
Person / Time
Site: Dresden, Browns Ferry, Oconee, Nine Mile Point, Watts Bar, Grand Gulf, Arkansas Nuclear, Surry, Turkey Point, River Bend, Clinton, FitzPatrick, LaSalle  
Issue date: 12/21/2018
From: Darrell Roberts
Engine Systems
To:
Document Control Desk, Division of Inspection and Regional Support
References
10CFR21-0123, Rev 1
Download: ML19002A204 (7)


Text

1111 12:02:45p.m.

12-21-2018 ENGINE SYSTEMS, INC.

175 Freight Road Rocky Moufll, NC 27804 Date:

Company:

Fax Number:

Verification No.:

Reference:

From:

Page:

DearSir:

TELEFAX December 21,. 2018 NRC Operations Center 301/816-5151 301/816-5100 Report No. 10CFR21-0123, Rev. 1 Dan Roberts 1 of7 Telephone: 252/9n-2120 Fax: 252/446-1134 Following this cover is a copy of our report 1 OCFR21-0123, Rev. 1, for a 1 OCFR21 reportable notification on EMD fuel and soakback pumps.

A copy :of the revised report wm be mailed to the NRC Document Control Desk and to our affected nuclear customers.

Should you have questions, please let us know.

Sincerely, ENGINE SYSTEMS, INC..

~

(MJ--

Dan Roberts Quality Manager

  • Quality Performance With Pride 1 /7

1111

~

ENGINE SYSTEMS, INC.

'@,I. 175 Freight Road, Rocky Mount, NC 27804 12:02:58 p.m.

12-21-2018 Telephone: 252/977-2720 Fax: 252/446-1134 Report No. 10CFR21-0123 Rev. 0:

11 /30/18 Rev. 1:

12/21/18 1 OCFR21 REPORTING OF DEFECTS AND NON-COMPLIANCE COMPONENT:

EMD Fuel and Soakback Pumps - Potentially Undertorqued Cover Bolts SYSTEM:

Emergency Diesel Generator CONCLUSION:

Reportable in Accordance With 10CFR21 Prepared By: -+-~

..... t

..... AM""""*a......---------

V-Engjneering Manager Date: 12/21 h8 Reviewed By: ___

fk::....o=.....;;* '--"141£----'-_

Date: _11_)_~_, /_,_~_

Quality Manager Quality Performance With Pride 2 /7

1111 12:03:09 p.m.

12-21-2018 3 /7 Report No.

10CFR21-0123 Record of Revisions Page:

1 of 1 REV DATE PAGE DESCRIPTION 1

12/21/18 2

In item (iv), added reference to F4B engine application.

In item (vii), revised recommended correction action to include a shaft freeness check and provide guidance for reduced bolt torque for previously Installed pumps.

1111 12:03: 19 p.m.

12-21-2018 417 Report No.

Revision:

1 OCFR21-0123 1

Date:

/

Page:

Pursuant to 10 CFR 21.21(d)(4l, ESI Is presenting the required information as follows:

(I) Name and address of the individual or individuals Informing the Commission.

Dan Roberts Quality Manager.

Engine Systems Inc.

175 Freight Rd.

Rocky Mount, NC 27804 John Kriesel Engineering Manager Engine Systems Inc.

175 Freight Rd.

Rpcky Mount, NC 278D4 12/21/18 1 of 2 (Ii) Identification of the basic component supplied within the United States which fails to comply or contains a defect.

EMD fuel and soakback pumps of the following part numbers:

Part Number Description 8410219 Fuel Pum/J; Flanaed Connections 8080284 Fuel Pump, Threaded Connections 8417074 Lube OIi Scavenging and Fuel Pump Assembly (16, 20-645E4, E4B},

Includes PIN 8410219 8252842 Lube Oil Scavenging and Fuel Pump Assembly (16, 20-B45E4),

Includes PIN 8080284 8417754 Lube OIi Scavenging and Fuel Pump Assembly (12-645E4, E4B),

includes PIN 8410219 8447715 Fuel Puma and Matar Assemblv. Includes PIN 8410219 8455818 Soaliback Puma and Motor Assemblv 8460815 Lube Oil Soakback and Fuel Puma (Iii) Identification of the firm supplying the basic component which fails to comply or contains a defect.

. Engine Systems Inc. (ES/)

(ht) Nature of the defect or failure to comply and the safety hazard which Is created or could be created by such defect of failure to comply.

ESI was notified by a nuclear customer of two Instances where a bolt was found loose or backed out of the cover of an EMD engine driven fuel pump PIN 8410219. Following notification, ES/ inspected remaining pumps in inventory and found Instances where one or more the pump cover bolts were loose or lightly torqued. See Figure 1 below for a visual depiction of the pump and bolts.

Pump Cover Bolts (qty 6) eJ i

I i i

.-~

Figure 1: Exploded Vlew*of Pump P/N B410219

1111 12:03:45 p.m.

12-21-2018 5 /7

  • Report No.

Revision:

1 OCFR21 ~0123 1

Date:

12/21/18 Page:

2of2 EMD fuel pump, PIN 8410219, is commonly used on all 12, 16, and 20-cylinder EMD model B45E4, E4B, and F4B engines. The pump is either mechanically driven from the engine (via the scavenging lube oil pump) or motor driven (as In the case of a backup/redundant fuel pump). The pump transfers fuel ail from the day tank to the fuel injectors to support fuel combustion. Without the supply of fuel oil, the diesel engine.ls unable to produce power which adversely affects the safety-related operation of the emergency diesel generator set.

(v) The date on which the Information of such defect or failure to comply was obtained.

October 24, 2018 (vi) In the case of a basic component which. contains a defect or falls to comply, the number and locatlon of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations In this part.

The extent of condition includes pump PIN 8410219 as well as the part numbers listed in Table 1 In Appendix A. Note that PIN 8080284 ls otherwise identical to PIN 8410219 except that the ports are threaded as apposed to flanged.

The scavenging pump assemblies listed are upper level assemblies that contain either PIN 8410219 or 8080284.

The fuel pump and motor assembly utilizes PIN 8410219.

The soakback pump assemblies listed use a pump made by the same manufacturer with similar construction and therefore a~ Included in the extent of condition.

Based on ESl's investigation the Issue may extend as far back "s 2014. Therefore, any of the pumps supplied from 2014 through 2018 are considered suspect.

(vii) The corrective action which has been, is being, or wlll be taken; the name of the Individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.

For all affected customers:

ES/ recommends inspecting the bolt tightness for all pumps. The recommended bolt torque Is 108 to 120 In-lbs (12 to 13 Nm). After verifying bolt torque, a shaft freeness check is recommended. The pump shaft should be capable of being rotated by hand In either.direction. Due to the small shaft size, this check is commonly performed with a small crescent wrench or with the coupling half installed on the shaft. Inability to rotate by hand indicates loss of end clearance and the pump should be returned to ES/ for rework or replacement.

Note: For Installed pumps where it is not possible to check shaft freeness, ES/ recommends using a reduced bait torque of BO to 70 In-lbs (7 to B Nm). This is sufficient to ensure the bolts are snug while safeguarding against lass of end clearance that would otherwise go undetected.

This activity should be performed at the earliest opportunity; however, it is mare important for the Inspection ta be performed on newly installed pumps. It is expected that for pumps supplied with law bolt torque, if a problem were to develop it would be In the form of a fuel leak ~oon after installation.

For pumps that have been successfully installed for several months or years with no detectable leakage, it is less likely that balt(s) are loose and therefore the urgency of this Inspection is reduced.

For ES/:

The dedication procedures for these pumps have been revised or are being revised to add a step ta verify proper bolt torque. This will be completed prior to any future shipments. In addition, ES/ is in correspondence with the pump manufacturer to Implement corrective actions to prevent reoccu"ence.

(viii) Any advice related to.the potential defect or failure to comply about the facility, activity, or basic component that has been, Is being, or will be given to purchasers or licensees, Verification of bolt tightness Is nan-invasive and may be performed with the pump installed (and operating). The baits are external to the pump and the cover is stationary; there Is no impact to pump operation or functionality while performing this inspection.

1111 I

I FUEL PUMP, RANGED CONNECTIONS, 8410219 ENGINE DRIVEN FUEL PUMP, THREADED CONNECIIONS, 8080284 ENGINE DRIVEN 12:04:22 p.m.

12-21-2018 6/7 FUJRlllA POW£R & LIGHT -ST WOE 02313521/00043 00003686221 I

TENNESSEE VAUEY AlJ!ltDRIJY -BROWN'S FERRY 713665 I 8410219 TENNESSEEVAU£Y AlllliDRITY-BROWN'S FERRY I 713m 8410219 ENm!GY OPERATIONS INC-GRA!lD GUif 10428304 1281504299 NUc..AR EXEi.ON *NINE MILE POINT 00544836 00016791791 ENIERGY OPERATIONS INC RIVER BEND ID43!lS23 ll!l32132608 NEXTERAENERGY POlffTBEACH UC 023135ZD/00080 D0065S9075 1 ENERGYNOl!lliWfST ll0344808 0058165345 El!El.ON -DRESDEN 70!; Rol.12686 00000436111 NlJa.EAR POWEii PLANT ICR5l(D+

3151747/14625 lOSBZS NUClfAR POWER PLANT KIISKO+

3151747/14625 10Sll:15 EXELON-LASAUE 00572185 DDD00436U1 SAVANNAH RIVER REMEDIATION UC SRIIAD69144 841021!1 ENTERGY OPERATIONS INC* GRANO GUif 10529624 1281504299 NUCLEAR EN£RGY NORTHWEST 00351174 0058165345 TENNESSEE VAUEY AUTHORITY* BRO\\IIN'S FERRY 3418640 CVT548N EXELON

  • DRESDEN D0646095 DODD0436111 ENERGY NOIIDIWEST D035U74 COSB165!!45 I

EXElON

  • NINE MILE POll'IT 00643368 D00167!1179 1 f DUKE£NERGY CAROUNAS UC* OCONEE NUClEAR 03D66435 DDDD157SS7

' EflTl:RGY DPERATIONS INC* GRAND GULF 10553808 12.B1504299 NUCLEAR EXELON-LASAUE 703; Rel 12989 0000043&U1 EXELON -CLINTON POWER PLANT 1703; Rel 12988.

OODD0436U1 PGS £NRIQUE MARIA HIERRO SL* ALMARAZ N2018/018 8410219 FUlRJDAPDWER & LIGHT* nJRKEY POINT ll231B3l1/DDD43 DOD17006871 OMAHA PUBUC POWER DISTRICT D02D4966 DOODD243791 FIRSTENERGYCORP*BEAVERVAUEY 45458123 8523787 PGS ENRIQUE MARIA HIERRO Sl-NUl:1£NOR N2016/0U 8080284 DOMINION VIRGINIA POWER

  • SUR RV POWER 4500298167 05006510 STATION EXEi.ON -Dl!ESDEN 703; Rel 12731 0000019419 1 EXEi.ON
  • FmPAlRICIC 703; Rel, 12927 DOJD5211221 EXEtON *NINE Mll.EPOlffT 703; Rel 12937 0001579GSS 1 EHmlGY OPERATlOliS INC-ARKANSA5 1DSSD517 OOD5511-71S Table 1: Ust of Affected Customers (continued on next page)

Report No.

Revision:

Appendix A Page:

7 03/27/14 4

Da/21/14 4

UB/Zl/JA 1

Dl/28/15 1

04/08/15 l*

04/0S/15 1

04/30/15 2

I D9/Z4/15 1

I 02/25/16 02/29/16 1

03/D3/16 4

DS/o&/16 2

12/05/16 2

rn./llS/lB 1

03/09/lB 1

03/16/lB 2

D&/lB/18 4

06/20/18 1

06/21/lB 1

08/01/lB 1

08/30/18 3

DB/30/18 3

D9/20/18 2

10/16/18 1

IJ2/2B/14 3

UB/15/14 2

01/29/15 1

D&/03/16 07/07/16 3

10/31/16 2

D3/27/lB 1

04/D3/18 2

08/30/18 1 OCFR21-0123 1

List of Affected Customers 1 of2 1271DS27 1271DS35 1271DS39 3012408 1.1 12710553 U7111544 U710548 12710552 12710671 12710566 8002290 20.1 U7l0551 12382313 12710676 8002290 34.1.

12710665 U71061i9 12710668 3013513 u

12710573 3013781 L1 12710664 3013974 Lt 12710675 3014099 1.1 8497750094 3014526 3.1 849792D1Z2 8497920128 3015071 1.1 8497750097 3014817 1.1 8497920112 3014817 u

849792DU4 12548101 12710734 3015350 1.1 8591700274 859t7oom 3015928 39.t l271D697 8591700290 3017555 2.1 127104D3 8591700273 3017807 1.1 81979600DO 30176BB 1.1 BS9170028t 3018069 1.1 8197850294 81949Gll191 S194S91l1Dt 3017807 L1 B194960189 8194960193 B1ll4li9D099 301BDOZ 1.1 B1949Gll194 3018132 L1 8196760103 30186UII Lt 81949611190 8196760104 3018649 u

8195760105 B19569D2Z4 8195690223 3018650 1.1 8195690229 8193640555 3018083 1.1 S19o76D1DD Sl9676llll1S 3012203 u

12523759 12523604 3DU9BD L1 125236/JS 12523800 3013189 L1 8591960081 8590700119 3015292 1.1 BS91700Z67 3015625 2.1 839676DU3 11396760112 3016024 Ll 8394S6D265 8392800023 3017678 Ll B2!l11730Z10 839486D261 30177~

Ll 8288890252 3D18470 L1 Bl.9492DDB9 819492D068

1111 8417074 LUBE OIL SCAVENGING & FUB. PUMP Sl52842 ASSEMBLY l11i,2D-645E4}

WITH P/N BDBD284 FUB. PUMP LUBE OIL SCAVENGING AND FUB.

0417754 PUMP ASSEMBLY (12-645E4, E4BJ WITH P/N B410219 RIEL PUMP 8447715 FUB. PUMP AND MDT1lR ASSEMBLY 0455818 SOAICIIAO: PUMP & MDTllRA55£MBLY 8460815 LUBE OIL SOAKIIACIC AND RIEi. PUMP 12:05:21 p.m.

12-21-2018 717 lENNESSEE VAUEf AIJil!ORnY

  • WAm BAR 2605647 OMAHA PUBUCPOWER DISTIIICT 00200346 DUKE ENERGY CAROUNAS llC
  • OCONEE NUClEAR ll3035494 00003307811 EXEi.ON
  • CUN!tlN POWER PIANT OOS72667 OOOW32240 DOMINION VIRGINIA POWER *SURRY P0!,1/El\\

45D03S634D 421126328 STATION DOMINIONVIRGINIAPDWER*SURRYPOWER 45003!!4508 42D26328 STATION ENERGY NDRTl!WEST OD345051 OD5816653S ENERGY NORTHWEST D0351743 011511166535 Table 1: List of Affected Customers Report No.

Revision:

Appendix A Page:

1 04/(JS/17 1

10/20/14 1

05/01/17 2

0'2/23/18 1

10/31/17 2

0'2/06/!Jl 3

01/12/16 2

06/25/18 10CFR21-0123 1

List of Affected Customers 2of2 3016354 1.1 12547923 3012561 2.1 12.523773 3Q16321 L1 8492750228 3D15S59 1.1 B295750D88 82957500!!9 31117171 L1 838777CD61 311173D6 1.1 8489910003 B4B7970!146 8587900264 31114666 3.1 B497B60219 B49390D1&1 I 3D18195 L1 B19Blll0DB4 Bl9BB2QD96