| issue date = 02/23/1981 | | issue date = 02/23/1981 | ||
| title = Forwards Proprietary & Nonproprietary Versions of Environ Qualification Review Rept, Vols 1 & 2,Revision 3.Requests Withholding (Ref 10CFR2.790) | | title = Forwards Proprietary & Nonproprietary Versions of Environ Qualification Review Rept, Vols 1 & 2,Revision 3.Requests Withholding (Ref 10CFR2.790) | ||
| author name = | | author name = Mittl R | ||
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY | | author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY | ||
| addressee name = | | addressee name = Miraglia F | ||
| addressee affiliation = NRC OFFICE OF NUCLEAR REACTOR REGULATION (NRR) | | addressee affiliation = NRC OFFICE OF NUCLEAR REACTOR REGULATION (NRR) | ||
| docket = 05000272, 05000311 | | docket = 05000272, 05000311 | ||
Line 17: | Line 17: | ||
=Text= | =Text= | ||
{{#Wiki_filter:r (' | {{#Wiki_filter:r (' | ||
Mr. Frank J. Miraglia; Chief Licensing Branch 3 Division of Licensing Gentlemen: | L e | ||
ENVIRONMENTAL QUALIFICATION REVIEW REPORT REVISION 3 NO. 2 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-311 PSE&G hereby submits Revision*3 to its report on mental Qualification of Class lE Instrumentation and trical Equipment. | PS~G I Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 February 23, 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Mr. Frank J. Miraglia; Chief Licensing Branch 3 Division of Licensing Gentlemen: | ||
This revision consists of both etary and non-proprietary replacement pages for the report which was submitted to you by letter dated November 26, 1980. As this submittal contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by the owners of the tion. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph | ENVIRONMENTAL QUALIFICATION REVIEW REPORT REVISION 3 NO. 2 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-311 PSE&G hereby submits Revision*3 to its report on Environ-mental Qualification of Class lE Instrumentation and Elec-trical Equipment. This revision consists of both propri-etary and non-proprietary replacement pages for the report which was submitted to you by letter dated November 26, 1980. | ||
{b) (4) of Section 2.790 of the Commission's regulations. | As this submittal contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse~ the owners of the informa-tion. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph {b) (4) of Section 2.790 of the Commission's regulations. | ||
Accordingly, it is respectfully requested that the-tion which is proprietary to Westinghouse be withheld from public disclosure in accordance with | Accordingly, it is respectfully requested that the- informa-tion which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations. Correspondence with respect \ | ||
Correspondence with respect \ to the proprietary aspects of this application for withhold-a...01/ ing, or the supporting Westinghouse affidavit should refer-1.1 h,R ence CAW-80-15, and should be addressed to R. A. Wiesemann; Manager, Regulatory and Legislative Westinghouse Electric Corporation, P.O. Box 355, Pennsylvania | to the proprietary aspects of this application for withhold- a...01/ | ||
ing, or the supporting Westinghouse affidavit should refer- 1.1 h,R ence CAW-80-15, and should be addressed to R. A. Wiesemann; ~ /~ | |||
Manager, Regulatory and Legislative Affairs~ Westinghouse ~\""~ | |||
Should you have any questions in this regard, do not tate to contact us. Very truly yours, CC: Mr. Leif Norrholm Senior Resident Inspector CKOl 1/2 | Electric Corporation, P.O. Box 355, Pittsburgh~ Pennsylvania \ | ||
15320. ~** | |||
p~L~)pr'\ . | |||
,.0. | |||
The Energy People ,., ~ *~ f.oli | |||
- | /J pofZ. | ||
*81022 60(pl5 .*,,, , , "p.M :5-0942 | |||
Director of Nuclear 2/23/81 Reactor Regulation This submittal consists of five (5) copies each of the proprietary and non-proprietary versions of this revision and one (1) copy of the supporting affidavit. | |||
Should you have any questions in this regard, do not hesi-tate to contact us. | |||
Very truly yours, f!f~** | |||
R. L. Mittl General Manager - | |||
Licensing and Environment CC: Mr. Leif Norrholm Senior Resident Inspector CKOl 1/2 | |||
SALEM GENERATING STATION UNITS 1 AND 2 DOCKET NOS. 50-272 AND 50-311 ENVIRONMENTAL QUALIFICATION REVIEW REPORT VOLUME 1 (NON-PROPRIETARY VERSION} | |||
/, SAl.c M eMEHGENCY OPEART/Nt$ | December 1, 1980 | ||
* M P81 11/06 Rev. 1 - 12/1/80 Rev. 2 - 1/10/81 Rev. 3 - 2/9/81 | |||
CAi.COLA/fo#s -Nl/tRoNMIENTAL a;t->Al.1- | |||
TABLE OF CONTENTS I Introduction II Review Philosophy/Procedure III Salem Environmental Zones and Conditions IV Master List of Components Located in a Harsh Environment (Vol. 2) v Q*ualification Data Review Forms VI Qualification Profiles (reference figures) | |||
/4.J *ZS, PA' c AAID ReSP()NJf ro 6,FSllN ; PAfc 6. 4 *10 Notes: | VII Justification for Continued Operation and Corrective Action to be Taken for Noted Deficiencies VIII Compliance with NUREG-0588 IX Quality Assurance Aspects x Review of Vendor Qualification Reports XI TMI Action Items XII Cold Shutdown Requirements | ||
£t'Et..5Y5rE,.,.-.s | * M P80 108 02/2 Rev. 3 L | ||
STATION UNITS 1 AND 2 FOUIPMF.NT QUALIFICATION | SALF.M CF.NF.RATING STATION UNITS 1 AND 2 FQUIP~1f.NT QUALIFICATION - FNVIRON~ffNTAT. | ||
-F.NVIRONMF.NTAL | l/ \I AT. H' TC' A 'I' Tn N nA 'I' A i" VI\ J. ti I\ T T0 N 1"(1 HM Page8/ | ||
ENVIRONMENT DOCUMENTATION EQUIPMENT DESCRIPTION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1if. Spec. Quali f. METHOD ITEMS REMARKS References System: CONTAINMENT Operating PIUUIMETERS Time LocA/MS£8 I NONE t./orE A Ident1ftcat1on: /, SAl.c M eMEHGENCY OPEART/Nt$ | |||
LA0223 f LAOZ24 PRoeEDIJRES 1*4.0,4.41 4., | |||
2.,p,s,E 4~ R4Dt47iofl/ CAi.COLA/fo#s PER 1;-Nl/tRoNMIENTAL a;t->Al.1-F°ICA"iTION R.GVIC.W Coq>c>nent: Temperature 271°/3§()*f! 3,4 R~ c;;J,(..JtRE_,.,,,cNT"5. | |||
LEVEL SWITCH -3. FSRR j FlflJN~ loS*5 AND | |||
/US Pr:WS£ TO ~5.82 f.t:il5".B5 4.NRC SER rOR SALEM (SUPP. 4)1 ltanuf1cturer: NU.'lie~ 05171 4/80; PIJ6E1*/() | |||
t:lt~M Pressure 43.2/42.8 s S. FSl/ll j rl~VRE /4.J *ZS, ~E PSI~ PA' c 14~*5' AAID ReSP()NJf ro ~5.42 f~5".B>' | |||
Model: LS*800 6,FSllN; PAfc 6. 4 *10 Relative 100 °lo -- | |||
Servtce: Humidity COAITlllPMe!Jr 5t/MP J.eVcL .2 WT~ | |||
Function: Chemical JJAOH G Spray 1.2 wr % | |||
801/ICMID Notes: | |||
Accuracy: Rad1at1on 5 x.10 1R 2 A. !?En Spec. | |||
Demon. % EcP~A t:!Ell 6yC'cwrAMJ~EAJr Locatton: | |||
"g1ng - ~* ~* lJArEil. t.. £t'Et..5Y5rE,.,.- i!cFE~ | |||
CONTlllJ{MEN1 a>&~e.s /£:>')//~ | |||
Flood Level El: ~3~ -1" Above Fl9q~ L~v~l:).1'4f..S | |||
!Submergence % % Al/11 % N'~ NOAIE -- | |||
~Revision ~ | |||
~ALF.M GF.NF.RATINr. STATION UNITS 1 AND 2 FOUIPMF.NT QUALIFICATION - F.NVIRONMF.NTAL QllAJ,Tl"ICATTON nATA 1-'VAltlATHlN FC11!M Page..1J24 EQUIPHEtlT DESCRIPTION ENVIRONMENT DOCUMENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1lf. Spec. Qual1f. MElllOD ITEMS REMARKS System: c.,11~c/LE.ToowN Operating RE.c.tR.c. s E.c."T' I OrV XD | |||
==References:== | ==References:== | ||
OPE.IUfTtN(r f'ROCE.DuRE:.S | Doc,lJl"lfrJTA-Time 1. ~AlEM OPE.IUfTtN(r f'ROCE.DuRE:.S ;; | ||
;; ) I-4.4, I-4., | ldenttt'1cation: I> 2- T101\1 12.0 Dfl<ls [*4.0 ) I-4.4, I-4., | ||
~ ,i?EV/EJ\J 2 FSARi C.H. b Component: | |||
BoR. 1c. Ac.1 ti IRANSfEI\. Pul"'I P Temprrature N/A N/A % fA NIA % 3.PS£~G RADIATION (.,/ll_~ULATIONS PER E.~ vl~oNMEllJTAL QUA!.\ F1c.- | |||
ATION lt!.v1e.w REQUIREME.llfT5 t'I O"t"O~ | |||
Manufacturer: Pressure WEsTuJG~ouse: | |||
(8u~FAL..O) | |||
Hodel: ~ | |||
Relative Service: Humidity RAP1ti BORATION "To ~c.s Function: | |||
D~'"'NC. PowER Chemical Spray | |||
\'J J It I | |||
.' I lo B.A.IRAllsff:f. | |||
PvN\P.s Notes: | |||
Flood Level El: | Accuracy: Radiation LID JR -- | ||
3 Spec. N/A Demon. | |||
"ging --- | |||
/, £ | Locatton: | ||
(.:i/3o J 2' RES uL.'TS oF f'SE 4G RADI RT101\1 u1..AT1orll5 P!!R | I Aux BL!:>c.- 100 Flood Level El: | ||
Above Flood Level: | |||
83'-l" Submergence | |||
~ N/,4 N/A NjA N/A i .Revision 3 | |||
5ALEM GF.NF.RATING STATION UtlITS l AND 2 FOUIPMENT QUALIFICATION - F.NVIRONMF.NTllL Ql!AT,HJCATlON 01\Tll FVl\J,lJl\TlON FOHM Page.JQS. | |||
ENVIRONMENT DOCUMENTATION EQUIPMENT DESCRIPTION QUALi FI CA Tl ON OUTSTANDING Parameter Spec. Qua ltf. Spec. Qual H. HETllOO ITEMS REMARKS References System: c "R.Vt.ETl)ow~ | |||
~E.c.1RC. | |||
Operating Time 12.ot>AVS | |||
> IC..0 ~Ys 3 I IESI No NC. /, £11teNE~ ffCHA.JIC,l/L tr""'uFlol-ldenttficat1on: r1o.u K£1'c/l.r hR.CN£~£LE-K AJc. E .i! 1.2~ (.:i/3o J N/A C011><>nent: Temprrature | |||
~ N;A % ~ NA NIA 2' RES uL.'TS oF f'SE 4G RADI RT101\1 CAl..U u1..AT1orll5 P!!R ENl/1R.0N-1-l E.AT T It.Ac:&: I AP MEl\l TAI- Q \)AL I F1c..m- 101\J Re:J1 E.lo..I Manuhcturer: :3 SAL EM oPERllTIN<'. fl~oc.eDut.c.5 Pressure I- 4. 0 1- 4 .4) :r-4 ob C:.11e.1¥t:~eJt J | |||
Model: Prv Relative Ser11ce: Humtdt ty RAPID e.oRAT1ot.> | |||
To RvS | |||
*[1 i. | |||
Function: Chemical ~ q, II' ti E.AT ~AP1b Spray **. | |||
T. ll\11\T.TFT\ATHlN | BO~RTE LINE Notes: | ||
Accuracy: Radtatton < 2.X \o 'R. 11C10 7 | |||
R, 2. I TE.ST No f\l t:. -- | |||
- | Spec. | ||
NA Demon. \ | |||
Location: Aux 8LPG- | |||
t..1F1c..A"T 10 N Re 111 e:w l)IREMENl5o | "gtng --- -- | ||
100/~+ | |||
~ NIA Flood Level El: 83'-1" Above Flood Level: | |||
!Submergence r--l/A N/A N/A | |||
) | - --- - ---- - Revision 3. | ||
( | |||
SALFM GFNERATTNr. STATION UNITS l AND 2 FOUIPMF.NT QUALIFICATION - F.NV IRONMF.NTI\ T. | |||
ll\11\T.TFT\ATHlN DATI\ FVAL\JATTON F0PM Page..J.O.b. | |||
EQUIPMENT DESCRIPTION ENVIRONMENT DOCUMENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1if. Spec. QualH. METHOD ITEMS REMARKS R. E.C.1 R. c. SEC..TICfJ'X11 References ystem: Aux. BLD~. Operating VcNf1L..AT10"1 Time I I. SALE'. M Ofle~ATING. PR~t::LJRe;$ | |||
ldent1ftcatton: I-4. oi I-4.4> I-4.~ | |||
e 00~ Co OL'7~ f'\ o\OR,. 12.o DAYS COllpOnent: TempPrature ry,. >>/4 A'fA >>JA #/A 2.. fSE (G- RADlf\T10N CALC.vLA- ' | |||
TION S PE.A. E.Nl/1Rol'.IMEN"TAL. | |||
f'llo-t"oi<. | |||
QuA t..1F1c..A"T 10 N Re 111 e:w RE(il l)IREMENl5o Manufacturer: Pressure ALLIS C.HALME.RS Hodel: | |||
Relative Sentce: Humidity Mcrr1vf. Pow~~ | |||
* | To f ~N Functtcn: Chemical Avx BLDG. Spray ** | ||
* _.__ -~ | |||
Ir YENTi L..ATION. | |||
Notes: | |||
Accuracy: Radiation | |||
< 'R -- | |||
6XIO 2.. | |||
Spec. | |||
Denon. N/A Aging Locatton: -- -- ' | |||
' | Au"' Bu)G- u /{145 I Flood Level ~~: | ||
bove Flood Level: | |||
83'-~* | |||
Submergence N/A tJ/A N/A N/A NjA N/A Revision 3_ | |||
I | SALF.M GF."ERATING STATION U"1TS l AND 2 | ||
*FOUIPMENT QUALIFICATIOR - F.NVIRONMF.NTAL 11\IAT TFtr.ATTON nATA l'VALllATION FORM EQUJPMEllT D£SCRIPT10N ENYIRONHENT OOCUHENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qualtf. Spec. Qua 1t f. METHOD 1T£HS RE HARKS REc1~c. SE.GTIOll.lZJI: ItlS\JfF 1c.1e"'1° Refe~nces Syste11: Aux. BLOC>. Operating Doo.Jl"l!NTA- | |||
\IE:m;1LATIOl\I ldenttfte&t on: | |||
/'R..:Jc.E.CXJffS 1 | . <,,V- "i'\' 1 ,04 Time 120D0..ys TION | ||
'* SALE. t1 OPERAillVG-r F:oc.£.DIJR.ES *l '!*4 ,o l :f-"4. 4 ) I-'4 . i. | |||
5,/-5"!7,S'llf ).t'I'\ ,,0"1 sv- t:oi>go~ l&os 1'o' SV- '. 0 8 ''O ,110 C~nent: | |||
Teq>Pr&ture ~ AJ/A AJ/-4 AJ/A ,AJ/.4 2.. rse tG- RADll\T10H CALC.!ILA-SOL.ENO![) 'IAL.llE.S TION 5 PE..R. Et..lv'IR.orJMENTAL I QUI'.1,..u*1c.A"T"10N R.e111 EW R E.<il l)lli!EM~N"fSo llanuf1cturer: Pressure ASCO Model: | |||
:rxnu.A~ | |||
Relative Serwtce: Humidity PILOT llALllE Functton: Chemical , ', | |||
V"L'lf.. QP&.RllT\oN Spray I Fol!. D""''~.e~/coo~ | |||
~dtatton | |||
,. Notes: | |||
Accuncr. ~ (;XIO A. 2. | |||
Spec. | |||
DellOft. N/A --* | |||
I Locatton: | |||
Agtng Au,.. BLDG* uXs' Flood Level ~1: "J'-r Above nood Level: | |||
Submergence NJA N/A N/A N/A I1 N/A N/A I | |||
\B.evisioo 3 | |||
dfER.ATIJtE-, | SALEM OF.NERATING STATION UNITS l AND 2 FOUIPMENT OUALIFICATIOR | ||
* F.NVIRONMF.NTAL I QUAiTFTCATTON nATA VVALUATTON FORM EQUIPMEllT DESCRIPTION ENVIRONMENT DOC"1ENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1H. Spec. Qua Hf. HETHOO ITEMS REMARKS R.Ec.1~c. | |||
S£CTlor\JIJI. I~S\JFF1c.1ellfl'" Refe~nces Syst*: Aux. 8L[)G.. Oper1ttng I Doc.ut'\l!NTI'- | |||
SALE f1 oP~~ltT1N(... /'R..:Jc.E.CXJffS 1 "E:mll.ATIOfol ldentt Heat on: | |||
/4. | TD-155S,154' 1 7S"'4 f Time 120 DAY.S TION | ||
; | '* !-4. D l I-4.4 ) I-4.' | ||
: | "TD-155°. 1547, 1554 tG- | ||
,. | ~ | ||
Teq>Prlture 2.. PSE IUDll\Trotl CALC.ULl\- | |||
- | CC111POnent: /J/4 AJ/,,.f AJ/-4 ,AJjA T10N 5 PE..R. EN>/IR.orJMENTAL "TEMP. Si,./11'cM QUI'.1...1..-1c..A110N Rev1E\J REO<il Vl'!EM~N'TS. | ||
ll1nufacturer: Pressure ; | |||
PE.NN llodel: | |||
A- I0.85C*'2... Rel1ttve Sen tee: H1111tdtty Func:tton: Chesntcal | |||
* coot.ER C.ONTROI... | |||
. | Spray .~ | ||
~ | |||
Notes: | |||
RAdtatton Accuracr. <.6XIO 'R 2. | |||
- | ..... N/A Spec | ||
* Io' | |||
~glng I | |||
* | II Location: -- i AUJ\ SLD~ u '~I s I Flood Level El: 83 1 ~1* | ||
Above Flood.Level: | |||
lsubllle rge nee NfA f\J/A r-J/A I I | |||
tJ/A ' | |||
* NjA N/A | |||
\.Revision 3 | |||
SALF.H GF.NF.RATING STATION UtlITS l AND 2 . | |||
FQUIPHENT QUALIFICATION - ENVIRONMENTAL QllAJ.HICATTON DATA FVAl.llATTON roHM Page-1!!.J EQUIPMENT DESCRIPTION ENVIRONMENT DOCUMENTATION QUALi FI CAT ION OUTSTANDING Parameter Spec. Qua 1lf. Spec. Qualif. METllOD ITEMS REMARKS i.P£11* t.£ References System: c.oNrAAJM~,.,,. | |||
Operating ux-A-/H51.E 8A51~~/ ~l/L-L-LcveL f"1P1Cllr1011J Ttme I f 'r-JN l>t°ll6ar~ | |||
ldenttftcatton: | |||
s&er101oJ X1f. /. ~/jl~J.f tNE~qcAIC.V dfER.ATIJtE-, | |||
LI- 'J30 ... STIN{q . | |||
Y'fol EP&.1/l.E~ I- *l-01 4.~1 4-t. | |||
1-r-~ ?>OJ Component: Temprrature .27t /$Or ~4 2- p.~ t* i (;,_ eA ()11J710Al cALeOLA11£><-h PU. vi lllfl~f./He.A/TAL- Qll.,L.1~ar1ool Low srAE:if HtD ~lfAf:iC E'fv1e-w eu~u1eHEl\JTs UPPtIL- -s-rA.(:i c | |||
:,. F.s Ae.. i r:;1~ut£ 7.~-5" ANb Manufacturer: Pressure '/!>2/'/2-8 5 ei:slbJJc. | |||
6E~$ f!.14 T1J Q5. 82. tj ~~ 8S-4 AJ ec. 5Er2 HJe S~t.El-f {s11PP.-4) | |||
Hodel (t..s) xM {pt)J1S° | |||
£'-15))(>.1 bOl7~ t1uea=1 0517) 1/Boi ~ ~-JO fif./?c:-1 "'°I 7 ~ - | |||
Relative Hum1dt ty too% - ~-F5AR. | |||
) ~It, /4.3 -z5 p~ ll/.3-st. ; | |||
CtJ~A11/l*ffJJI AAJ.D etsto4C£ 10 /'1 1 | |||
.5t/1fp leV1- ,z W1" '% (,. F$Ae : PA~E ,.4- lo | |||
'-'S'.BZ ~ lil$*BS': | |||
Function: Chemical N~ | |||
'2 | |||
~ | |||
Spray f.2. .,vr% | |||
L£VE.L l~blUITION P-;JP 1G At:.1D Notes: | |||
Accuracy: Rad1atton -- | |||
Spec. | |||
DelllOn. | |||
% 5*110112 12.o f:..tys 11\ging -- | |||
Locatton: | |||
CD/tJTA1AlM c/Jr Flood Leve1 El: 83 1 -1* | |||
~ubmer!!efl~e Above Floo~ Level: | |||
L | |||
~Revision 3 | |||
SALEM GF.NERATING STATION UNITS 1 AND 2 F.OUIPMENT QUALIFIC~TION - F.NVIRONMENTAL QIJAJ,H'TCATTON nATA ,.. VAl.llATTON rnHM . PagejJQ_ | |||
ENVIRONMENT DOCUMENTATION EQUIPMENT DESCRIPTION QUALIFICATION OUTSTANDING Parameter Spec. Qua 11 f. Spec. QualH. METltOD ITEMS REMARKS References Syste111: Operating EA!115~31 PE:I/ lc...E" Time REc1ec. 2 4 6r1LL-I. PSE tG lf.AOIATIO~ C.ALC..vc.A'TIO Identification: .SEC.T ro.v.21[ v/Jl>C~CI~ Pe~ ENlll/!orJf'1£'1ffll L QuA L. - | |||
LT- ~38 2.. W5nNL-, 1F1c l?;ION ~£V/EIA.) /l.E~l/t~~ | |||
LT- 4:).3~ '/;_ | |||
Temprr;sture A//A ,JJ/I/ AJ/.4 AJ/4 ,A)/,4 2, .SAt..1: l'1 oPER.AT/Nt:; PRoc.Eb Cai.,onent: | |||
1-4. o J 1-4.4 ) I-4." | |||
"REC IE' II ER... | |||
Ma nuf ac turer: Pressure I 6E~~ | |||
I j | |||
I Hodel: ' | |||
RE7'b0/72 Relative Service: Humidity R.fCIE.iJ~S ~/~t.S | |||
~()f!. .5alfi> Lt-11EL l/JplG Function: Chemical LEV£L. [fllC>/,/fT/ON Spray - -- ~ ' | |||
~ | |||
Notes: | |||
Accuracy: Rad1at1on L 10 !::le. -- | |||
I Spec. | |||
Del!Ol'I. | |||
Nfa no fJo.-ys | |||
~g1ng Location: -- - -- | |||
EiclTl!llAL. polf l Flood level El: e3'-r :>ubmergence Al>ove. fl ~od ~eve 1: | |||
1J Bevision 3}} |
Latest revision as of 08:21, 3 February 2020
ML18085A912 | |
Person / Time | |
---|---|
Site: | Salem |
Issue date: | 02/23/1981 |
From: | Mittl R Public Service Enterprise Group |
To: | Miraglia F Office of Nuclear Reactor Regulation |
Shared Package | |
ML18085A914 | List: |
References | |
NUDOCS 8102260615 | |
Download: ML18085A912 (12) | |
Text
r ('
L e
PS~G I Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 February 23, 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Mr. Frank J. Miraglia; Chief Licensing Branch 3 Division of Licensing Gentlemen:
ENVIRONMENTAL QUALIFICATION REVIEW REPORT REVISION 3 NO. 2 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-311 PSE&G hereby submits Revision*3 to its report on Environ-mental Qualification of Class lE Instrumentation and Elec-trical Equipment. This revision consists of both propri-etary and non-proprietary replacement pages for the report which was submitted to you by letter dated November 26, 1980.
As this submittal contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse~ the owners of the informa-tion. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph {b) (4) of Section 2.790 of the Commission's regulations.
Accordingly, it is respectfully requested that the- informa-tion which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations. Correspondence with respect \
to the proprietary aspects of this application for withhold- a...01/
ing, or the supporting Westinghouse affidavit should refer- 1.1 h,R ence CAW-80-15, and should be addressed to R. A. Wiesemann; ~ /~
Manager, Regulatory and Legislative Affairs~ Westinghouse ~\""~
Electric Corporation, P.O. Box 355, Pittsburgh~ Pennsylvania \
15320. ~**
p~L~)pr'\ .
,.0.
The Energy People ,., ~ *~ f.oli
/J pofZ.
- 81022 60(pl5 .*,,, , , "p.M :5-0942
Director of Nuclear 2/23/81 Reactor Regulation This submittal consists of five (5) copies each of the proprietary and non-proprietary versions of this revision and one (1) copy of the supporting affidavit.
Should you have any questions in this regard, do not hesi-tate to contact us.
Very truly yours, f!f~**
R. L. Mittl General Manager -
Licensing and Environment CC: Mr. Leif Norrholm Senior Resident Inspector CKOl 1/2
SALEM GENERATING STATION UNITS 1 AND 2 DOCKET NOS. 50-272 AND 50-311 ENVIRONMENTAL QUALIFICATION REVIEW REPORT VOLUME 1 (NON-PROPRIETARY VERSION}
December 1, 1980
- M P81 11/06 Rev. 1 - 12/1/80 Rev. 2 - 1/10/81 Rev. 3 - 2/9/81
TABLE OF CONTENTS I Introduction II Review Philosophy/Procedure III Salem Environmental Zones and Conditions IV Master List of Components Located in a Harsh Environment (Vol. 2) v Q*ualification Data Review Forms VI Qualification Profiles (reference figures)
VII Justification for Continued Operation and Corrective Action to be Taken for Noted Deficiencies VIII Compliance with NUREG-0588 IX Quality Assurance Aspects x Review of Vendor Qualification Reports XI TMI Action Items XII Cold Shutdown Requirements
- M P80 108 02/2 Rev. 3 L
SALF.M CF.NF.RATING STATION UNITS 1 AND 2 FQUIP~1f.NT QUALIFICATION - FNVIRON~ffNTAT.
l/ \I AT. H' TC' A 'I' Tn N nA 'I' A i" VI\ J. ti I\ T T0 N 1"(1 HM Page8/
ENVIRONMENT DOCUMENTATION EQUIPMENT DESCRIPTION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1if. Spec. Quali f. METHOD ITEMS REMARKS References System: CONTAINMENT Operating PIUUIMETERS Time LocA/MS£8 I NONE t./orE A Ident1ftcat1on: /, SAl.c M eMEHGENCY OPEART/Nt$
LA0223 f LAOZ24 PRoeEDIJRES 1*4.0,4.41 4.,
2.,p,s,E 4~ R4Dt47iofl/ CAi.COLA/fo#s PER 1;-Nl/tRoNMIENTAL a;t->Al.1-F°ICA"iTION R.GVIC.W Coq>c>nent: Temperature 271°/3§()*f! 3,4 R~ c;;J,(..JtRE_,.,,,cNT"5.
LEVEL SWITCH -3. FSRR j FlflJN~ loS*5 AND
/US Pr:WS£ TO ~5.82 f.t:il5".B5 4.NRC SER rOR SALEM (SUPP. 4)1 ltanuf1cturer: NU.'lie~ 05171 4/80; PIJ6E1*/()
t:lt~M Pressure 43.2/42.8 s S. FSl/ll j rl~VRE /4.J *ZS, ~E PSI~ PA' c 14~*5' AAID ReSP()NJf ro ~5.42 f~5".B>'
Model: LS*800 6,FSllN; PAfc 6. 4 *10 Relative 100 °lo --
Servtce: Humidity COAITlllPMe!Jr 5t/MP J.eVcL .2 WT~
Function: Chemical JJAOH G Spray 1.2 wr %
801/ICMID Notes:
Accuracy: Rad1at1on 5 x.10 1R 2 A. !?En Spec.
Demon. % EcP~A t:!Ell 6yC'cwrAMJ~EAJr Locatton:
"g1ng - ~* ~* lJArEil. t.. £t'Et..5Y5rE,.,.- i!cFE~
CONTlllJ{MEN1 a>&~e.s /£:>')//~
Flood Level El: ~3~ -1" Above Fl9q~ L~v~l:).1'4f..S
!Submergence % % Al/11 % N'~ NOAIE --
~Revision ~
~ALF.M GF.NF.RATINr. STATION UNITS 1 AND 2 FOUIPMF.NT QUALIFICATION - F.NVIRONMF.NTAL QllAJ,Tl"ICATTON nATA 1-'VAltlATHlN FC11!M Page..1J24 EQUIPHEtlT DESCRIPTION ENVIRONMENT DOCUMENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1lf. Spec. Qual1f. MElllOD ITEMS REMARKS System: c.,11~c/LE.ToowN Operating RE.c.tR.c. s E.c."T' I OrV XD
References:
Doc,lJl"lfrJTA-Time 1. ~AlEM OPE.IUfTtN(r f'ROCE.DuRE:.S ;;
ldenttt'1cation: I> 2- T101\1 12.0 Dfl<ls [*4.0 ) I-4.4, I-4.,
~ ,i?EV/EJ\J 2 FSARi C.H. b Component:
BoR. 1c. Ac.1 ti IRANSfEI\. Pul"'I P Temprrature N/A N/A % fA NIA % 3.PS£~G RADIATION (.,/ll_~ULATIONS PER E.~ vl~oNMEllJTAL QUA!.\ F1c.-
ATION lt!.v1e.w REQUIREME.llfT5 t'I O"t"O~
Manufacturer: Pressure WEsTuJG~ouse:
(8u~FAL..O)
Hodel: ~
Relative Service: Humidity RAP1ti BORATION "To ~c.s Function:
D~'"'NC. PowER Chemical Spray
\'J J It I
.' I lo B.A.IRAllsff:f.
PvN\P.s Notes:
Accuracy: Radiation LID JR --
3 Spec. N/A Demon.
"ging ---
Locatton:
I Aux BL!:>c.- 100 Flood Level El:
Above Flood Level:
83'-l" Submergence
~ N/,4 N/A NjA N/A i .Revision 3
5ALEM GF.NF.RATING STATION UtlITS l AND 2 FOUIPMENT QUALIFICATION - F.NVIRONMF.NTllL Ql!AT,HJCATlON 01\Tll FVl\J,lJl\TlON FOHM Page.JQS.
ENVIRONMENT DOCUMENTATION EQUIPMENT DESCRIPTION QUALi FI CA Tl ON OUTSTANDING Parameter Spec. Qua ltf. Spec. Qual H. HETllOO ITEMS REMARKS References System: c "R.Vt.ETl)ow~
~E.c.1RC.
Operating Time 12.ot>AVS
> IC..0 ~Ys 3 I IESI No NC. /, £11teNE~ ffCHA.JIC,l/L tr""'uFlol-ldenttficat1on: r1o.u K£1'c/l.r hR.CN£~£LE-K AJc. E .i! 1.2~ (.:i/3o J N/A C011><>nent: Temprrature
~ N;A % ~ NA NIA 2' RES uL.'TS oF f'SE 4G RADI RT101\1 CAl..U u1..AT1orll5 P!!R ENl/1R.0N-1-l E.AT T It.Ac:&: I AP MEl\l TAI- Q \)AL I F1c..m- 101\J Re:J1 E.lo..I Manuhcturer: :3 SAL EM oPERllTIN<'. fl~oc.eDut.c.5 Pressure I- 4. 0 1- 4 .4) :r-4 ob C:.11e.1¥t:~eJt J
Model: Prv Relative Ser11ce: Humtdt ty RAPID e.oRAT1ot.>
To RvS
- [1 i.
Function: Chemical ~ q, II' ti E.AT ~AP1b Spray **.
BO~RTE LINE Notes:
Accuracy: Radtatton < 2.X \o 'R. 11C10 7
Spec.
NA Demon. \
Location: Aux 8LPG-
"gtng --- --
100/~+
~ NIA Flood Level El: 83'-1" Above Flood Level:
!Submergence r--l/A N/A N/A
- --- - ---- - Revision 3.
(
SALFM GFNERATTNr. STATION UNITS l AND 2 FOUIPMF.NT QUALIFICATION - F.NV IRONMF.NTI\ T.
ll\11\T.TFT\ATHlN DATI\ FVAL\JATTON F0PM Page..J.O.b.
EQUIPMENT DESCRIPTION ENVIRONMENT DOCUMENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1if. Spec. QualH. METHOD ITEMS REMARKS R. E.C.1 R. c. SEC..TICfJ'X11 References ystem: Aux. BLD~. Operating VcNf1L..AT10"1 Time I I. SALE'. M Ofle~ATING. PR~t::LJRe;$
ldent1ftcatton: I-4. oi I-4.4> I-4.~
e 00~ Co OL'7~ f'\ o\OR,. 12.o DAYS COllpOnent: TempPrature ry,. >>/4 A'fA >>JA #/A 2.. fSE (G- RADlf\T10N CALC.vLA- '
TION S PE.A. E.Nl/1Rol'.IMEN"TAL.
f'llo-t"oi<.
QuA t..1F1c..A"T 10 N Re 111 e:w RE(il l)IREMENl5o Manufacturer: Pressure ALLIS C.HALME.RS Hodel:
Relative Sentce: Humidity Mcrr1vf. Pow~~
To f ~N Functtcn: Chemical Avx BLDG. Spray **
- _.__ -~
Ir YENTi L..ATION.
Notes:
Accuracy: Radiation
< 'R --
6XIO 2..
Spec.
Denon. N/A Aging Locatton: -- -- '
Au"' Bu)G- u /{145 I Flood Level ~~:
bove Flood Level:
83'-~*
Submergence N/A tJ/A N/A N/A NjA N/A Revision 3_
SALF.M GF."ERATING STATION U"1TS l AND 2
- FOUIPMENT QUALIFICATIOR - F.NVIRONMF.NTAL 11\IAT TFtr.ATTON nATA l'VALllATION FORM EQUJPMEllT D£SCRIPT10N ENYIRONHENT OOCUHENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qualtf. Spec. Qua 1t f. METHOD 1T£HS RE HARKS REc1~c. SE.GTIOll.lZJI: ItlS\JfF 1c.1e"'1° Refe~nces Syste11: Aux. BLOC>. Operating Doo.Jl"l!NTA-
\IE:m;1LATIOl\I ldenttfte&t on:
. <,,V- "i'\' 1 ,04 Time 120D0..ys TION
'* SALE. t1 OPERAillVG-r F:oc.£.DIJR.ES *l '!*4 ,o l :f-"4. 4 ) I-'4 . i.
5,/-5"!7,S'llf ).t'I'\ ,,0"1 sv- t:oi>go~ l&os 1'o' SV- '. 0 8 O ,110 C~nent:
Teq>Pr&ture ~ AJ/A AJ/-4 AJ/A ,AJ/.4 2.. rse tG- RADll\T10H CALC.!ILA-SOL.ENO![) 'IAL.llE.S TION 5 PE..R. Et..lv'IR.orJMENTAL I QUI'.1,..u*1c.A"T"10N R.e111 EW R E.<il l)lli!EM~N"fSo llanuf1cturer: Pressure ASCO Model:
- rxnu.A~
Relative Serwtce: Humidity PILOT llALllE Functton: Chemical , ',
V"L'lf.. QP&.RllT\oN Spray I Fol!. D""~.e~/coo~
~dtatton
,. Notes:
Accuncr. ~ (;XIO A. 2.
Spec.
DellOft. N/A --*
I Locatton:
Agtng Au,.. BLDG* uXs' Flood Level ~1: "J'-r Above nood Level:
Submergence NJA N/A N/A N/A I1 N/A N/A I
\B.evisioo 3
SALEM OF.NERATING STATION UNITS l AND 2 FOUIPMENT OUALIFICATIOR
- F.NVIRONMF.NTAL I QUAiTFTCATTON nATA VVALUATTON FORM EQUIPMEllT DESCRIPTION ENVIRONMENT DOC"1ENTATION QUALIFICATION OUTSTANDING Parameter Spec. Qua 1H. Spec. Qua Hf. HETHOO ITEMS REMARKS R.Ec.1~c.
S£CTlor\JIJI. I~S\JFF1c.1ellfl'" Refe~nces Syst*: Aux. 8L[)G.. Oper1ttng I Doc.ut'\l!NTI'-
SALE f1 oP~~ltT1N(... /'R..:Jc.E.CXJffS 1 "E:mll.ATIOfol ldentt Heat on:
TD-155S,154' 1 7S"'4 f Time 120 DAY.S TION
'* !-4. D l I-4.4 ) I-4.'
"TD-155°. 1547, 1554 tG-
~
Teq>Prlture 2.. PSE IUDll\Trotl CALC.ULl\-
CC111POnent: /J/4 AJ/,,.f AJ/-4 ,AJjA T10N 5 PE..R. EN>/IR.orJMENTAL "TEMP. Si,./11'cM QUI'.1...1..-1c..A110N Rev1E\J REO<il Vl'!EM~N'TS.
ll1nufacturer: Pressure ;
PE.NN llodel:
A- I0.85C*'2... Rel1ttve Sen tee: H1111tdtty Func:tton: Chesntcal
- coot.ER C.ONTROI...
Spray .~
~
Notes:
RAdtatton Accuracr. <.6XIO 'R 2.
..... N/A Spec
- Io'
~glng I
II Location: -- i AUJ\ SLD~ u '~I s I Flood Level El: 83 1 ~1*
Above Flood.Level:
lsubllle rge nee NfA f\J/A r-J/A I I
tJ/A '
- NjA N/A
\.Revision 3
SALF.H GF.NF.RATING STATION UtlITS l AND 2 .
FQUIPHENT QUALIFICATION - ENVIRONMENTAL QllAJ.HICATTON DATA FVAl.llATTON roHM Page-1!!.J EQUIPMENT DESCRIPTION ENVIRONMENT DOCUMENTATION QUALi FI CAT ION OUTSTANDING Parameter Spec. Qua 1lf. Spec. Qualif. METllOD ITEMS REMARKS i.P£11* t.£ References System: c.oNrAAJM~,.,,.
Operating ux-A-/H51.E 8A51~~/ ~l/L-L-LcveL f"1P1Cllr1011J Ttme I f 'r-JN l>t°ll6ar~
ldenttftcatton:
s&er101oJ X1f. /. ~/jl~J.f tNE~qcAIC.V dfER.ATIJtE-,
LI- 'J30 ... STIN{q .
Y'fol EP&.1/l.E~ I- *l-01 4.~1 4-t.
1-r-~ ?>OJ Component: Temprrature .27t /$Or ~4 2- p.~ t* i (;,_ eA ()11J710Al cALeOLA11£><-h PU. vi lllfl~f./He.A/TAL- Qll.,L.1~ar1ool Low srAE:if HtD ~lfAf:iC E'fv1e-w eu~u1eHEl\JTs UPPtIL- -s-rA.(:i c
- ,. F.s Ae.. i r:;1~ut£ 7.~-5" ANb Manufacturer: Pressure '/!>2/'/2-8 5 ei:slbJJc.
6E~$ f!.14 T1J Q5. 82. tj ~~ 8S-4 AJ ec. 5Er2 HJe S~t.El-f {s11PP.-4)
Hodel (t..s) xM {pt)J1S°
£'-15))(>.1 bOl7~ t1uea=1 0517) 1/Boi ~ ~-JO fif./?c:-1 "'°I 7 ~ -
Relative Hum1dt ty too% - ~-F5AR.
) ~It, /4.3 -z5 p~ ll/.3-st. ;
CtJ~A11/l*ffJJI AAJ.D etsto4C£ 10 /'1 1
.5t/1fp leV1- ,z W1" '% (,. F$Ae : PA~E ,.4- lo
'-'S'.BZ ~ lil$*BS':
Function: Chemical N~
'2
~
Spray f.2. .,vr%
L£VE.L l~blUITION P-;JP 1G At:.1D Notes:
Accuracy: Rad1atton --
Spec.
DelllOn.
% 5*110112 12.o f:..tys 11\ging --
Locatton:
CD/tJTA1AlM c/Jr Flood Leve1 El: 83 1 -1*
~ubmer!!efl~e Above Floo~ Level:
L
~Revision 3
SALEM GF.NERATING STATION UNITS 1 AND 2 F.OUIPMENT QUALIFIC~TION - F.NVIRONMENTAL QIJAJ,H'TCATTON nATA ,.. VAl.llATTON rnHM . PagejJQ_
ENVIRONMENT DOCUMENTATION EQUIPMENT DESCRIPTION QUALIFICATION OUTSTANDING Parameter Spec. Qua 11 f. Spec. QualH. METltOD ITEMS REMARKS References Syste111: Operating EA!115~31 PE:I/ lc...E" Time REc1ec. 2 4 6r1LL-I. PSE tG lf.AOIATIO~ C.ALC..vc.A'TIO Identification: .SEC.T ro.v.21[ v/Jl>C~CI~ Pe~ ENlll/!orJf'1£'1ffll L QuA L. -
LT- ~38 2.. W5nNL-, 1F1c l?;ION ~£V/EIA.) /l.E~l/t~~
LT- 4:).3~ '/;_
Temprr;sture A//A ,JJ/I/ AJ/.4 AJ/4 ,A)/,4 2, .SAt..1: l'1 oPER.AT/Nt:; PRoc.Eb Cai.,onent:
1-4. o J 1-4.4 ) I-4."
Ma nuf ac turer: Pressure I 6E~~
I j
I Hodel: '
RE7'b0/72 Relative Service: Humidity R.fCIE.iJ~S ~/~t.S
~()f!. .5alfi> Lt-11EL l/JplG Function: Chemical LEV£L. [fllC>/,/fT/ON Spray - -- ~ '
~
Notes:
Accuracy: Rad1at1on L 10 !::le. --
I Spec.
Del!Ol'I.
Nfa no fJo.-ys
~g1ng Location: -- - --
EiclTl!llAL. polf l Flood level El: e3'-r :>ubmergence Al>ove. fl ~od ~eve 1:
1J Bevision 3