Forwards Application for Amend to License NPF-3,revising Tech Specs 4.4.5, Steam Generators Surveillance Requirements & Bases 3/4.4.5, Steam Generators, to Allow Use of B&W Sleeving Process for Steam Generator Tube Repair
ML20077P940
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/16/1991
From: Shelton D
CENTERIOR ENERGY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20077P944 List:
References
1927, TAC-M81298, NUDOCS 9108200139
Download: ML20077P940 (2)


Text

_ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ - _ _ _ _

.s CENTERDOR ENERGY Doneed C. Shdton XI0 Maison Avenue Vce President Nuclear isedo OH 436520001 Davis Besse (419)2492X10 Docket Number 50-346 ,

I License Number NPF-3 i l

Serial Number 1927 I

August 16, 1991 1

United States Nuclear Regulatory Commission Document Control. Desk Vashington, D. C. 20555

Subject:

License Amendment Application to Revise Technical Specification 4.4.5 (Steam Generators Surveillance Requirements) and Bases 3/4.4.5 (Steam Generators)

Gentlemen:

Enclosed is an application for an amendment to the Davis-Besse Nuclear Power Station (DBNPS), Unit Number 1 Operating License Number NPF-3, Appendix A, Technical Specifications (TS) to reflect the changes attached. The proposed changes involve TS 4.4.5 (Steam Generator Surveillance Requirements) and TS Bases 3/4.4.5 (Steam Generators).

This request proposes that TS 4.4.5 and Bases 3/4.4.5 be revised to allow the use of the Babcock and Vilcox (B&V) Sleeving Process for Steam Generator (SG) Tube repair. This revir'on vill provide Davis-Besse with an alternative to plugging for repairing defective SG tubes, Use of sleeving vill minimize the impact of defective tubes on primary flow margin and heat transfer. Toledo Edison requests that this amendment be issued by the NRC by August 31, 1992.

9108200139 .0816 FDR ADOCK 4 0 0 0 M 6~

P PDR [O(I opemng companies !I i Cleveiond Eie:tnc litumnonng d l loledo Ed! son

P" Docket Number 50-346 License Number NPP-3

. Serial Number 1927 Page 2  !

k If you have any questions regarding this amendment request, please contact l Hr. R. V. Schrauder, Manager - Nuclear Licensing, at (419) 249-2366.

Very t ly you.s, e - ~ 'N

['7 7 " x ' - ~ ' ~ ~ ~g Hill /mmb ' -

i cca P. H. Byron, NRC Region III, DB-1 Senior Resident Inspector [

A. B. Davis, Regional Administrator, NRC Region III l J. B. Hopkins, NRC/NRR DB-1 Senior Project Manager l

J. R. Villiams, Chief of Staff, Ohio Emergency Management Agency,  ;

State of Ohlr,(NRC Liaison',  !

Utility Radiological Safety Board i

)

l l-l l l i

I

(

i

?

i 1

f i

l

[

I I r I

o I l '

i  :

-