{{#Wiki_filter:Exelon RS-16-177 November 28, 2016 U.S. Nuclear Regulatory Commission A TIN: Document Control Desk Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 1 O CFR 50.54(f) Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRG Docket Nos. 50-352 and 50-353  
{{#Wiki_filter:Exelon Generation ~,
RS-16-177                                                               10 CFR 50.54(f)
November 28, 2016 U.S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRG Docket Nos. 50-352 and 50-353


==Subject:==
==Subject:==
High Frequency Supplement to Seismic Hazard Screening Report, Response to NRG Request for Information Pursuant to 1 O CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident  
High Frequency Supplement to Seismic Hazard Screening Report, Response to NRG Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident


==References:==
==References:==
: 1. NRG Letter, Request for Information Pursuant to Title 1 O of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 12, 2012(ML12053A340}
: 1. NRG Letter, Request for Information Pursuant to Title 1O of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 12, 2012(ML12053A340}
: 2. NRG Letter, Electric Power Research Institute Report 3002000704, "Seismic Evaluation Guidance:
: 2. NRG Letter, Electric Power Research Institute Report 3002000704, "Seismic Evaluation Guidance: Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," As An Acceptable Alternative to the March 12, 2012, Information Request for Seismic Reevaluations, dated May 7, 2013 (ML13106A331)
Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," As An Acceptable Alternative to the March 12, 2012, Information Request for Seismic Reevaluations, dated May 7, 2013 (ML 13106A331)
: 3. NEI Letter, Final Draft of Industry Seismic Evaluation Guidance, Screening, Prioritization and Implementation Details (SPID) for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic (EPRI 1025287), dated November 27, 2012 (ML12333A168 and ML12333A170)
: 3. NEI Letter, Final Draft of Industry Seismic Evaluation Guidance, Screening, Prioritization and Implementation Details (SPID) for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic (EPRI 1025287), dated November 27, 2012 (ML 12333A 168 and ML 12333A 170) 4. NRG Letter, Endorsement of Electric Power Research Institute Final Draft Report 1025287, "Seismic Evaluation Guidance, Screening, Prioritization and Implementation Details (SPID) for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," dated February 15, 2013(ML12319A074)
: 4. NRG Letter, Endorsement of Electric Power Research Institute Final Draft Report 1025287, "Seismic Evaluation Guidance, Screening, Prioritization and Implementation Details (SPID) for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," dated February 15, 2013(ML12319A074)
: 5. Exelon Generation Company, LLC letter to NRG, Limerick Generating Station, Units 1 and 2 -Seismic Hazard and Screening Report (CEUS Sites}, Response to NRG Request for Information Pursuant to 1 OCFR50.54(f)
: 5. Exelon Generation Company, LLC letter to NRG, Limerick Generating Station, Units 1 and 2 - Seismic Hazard and Screening Report (CEUS Sites}, Response to NRG Request for Information Pursuant to 10CFR50.54(f) Regarding Recommendation 2.1 of Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated March 31, 2014 (RS-14-069) (ML14090A236}
Regarding Recommendation 2.1 of Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated March 31, 2014 (RS-14-069) (ML 14090A236}
 
U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 28, 2016 Page 2 6. NRC Letter, Screening and Prioritization Results Regarding Information Pursuant to Title 1 O of the Code of Federal Regulations 50.54(f) Regarding Seismic Hazard evaluations for Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated May 9, 2014 (ML 14111A147)
U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 28, 2016 Page 2
: 7. NRC Memorandum, Support Document for Screening and Prioritization Results Regarding Seismic Hazard Re-Evaluation for Operating Reactors in the Central and Eastern United States, dated May 21, 2014 (ML 14136A 126) 8. NEI Letter, Request for NRC Endorsement of High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396), dated July 30, 2015 (ML 15223A 100/ML 15223A 102) 9. NRC Letter to NEI: Endorsement of Electric Power Research Institute Final Draft Report 3002004396: "High Frequency Program: Application Guidance for Functional Confirmation and Fragility," dated September 17, 2015 (ML15218A569) 1 O. NRC Letter, Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 1 O of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated October 27, 2015 (ML 15194A015)
: 6. NRC Letter, Screening and Prioritization Results Regarding Information Pursuant to Title 1O of the Code of Federal Regulations 50.54(f) Regarding Seismic Hazard Re-evaluations for Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated May 9, 2014 (ML14111A147)
On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued a Request for Information per 1 O CFR 50.54(f) (Reference
: 7. NRC Memorandum, Support Document for Screening and Prioritization Results Regarding Seismic Hazard Re-Evaluation for Operating Reactors in the Central and Eastern United States, dated May 21, 2014 (ML14136A126)
: 1) to all power reactor licensees.
: 8. NEI Letter, Request for NRC Endorsement of High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396),
The required response section of Enclosure 1 of Reference 1 indicated that licensees should provide a Seismic Hazard Evaluation and Screening Report within 1.5 years from the date of the letter for Central and Eastern United States (CEUS) nuclear power plants. By NRC letter dated May 7, 2013 (Reference 2), the date to submit the report was extended to March 31, 2014. By letter dated May 9, 2014 (Reference 6), the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation report for Limerick Generating Station, Units 1 and 2 submitted on March 31, 2014 (Reference 5). In accordance with the Screening, Prioritization, and Implementation Details report (SPID) (References 3 and 4), and Augmented Approach Guidance (Reference 2), the reevaluated seismic hazard is used to determine if additional seismic risk evaluations are warranted for a plant. Specifically, the reevaluated horizontal Ground Motion Response Spectrum (GMRS) at the control point elevation is compared to the existing Safe Shutdown Earthquake (SSE) or Individual Plant Examination for External Events (IPEEE) High Confidence of Low Probability of Failure (HCLPF) Spectrum (IHS) to determine if a plant is required to perform a high frequency confirmation evaluation.
dated July 30, 2015 (ML15223A100/ML15223A102)
As noted in the May 9, 2014 letter from the NRC (Reference
: 9. NRC Letter to NEI: Endorsement of Electric Power Research Institute Final Draft Report 3002004396: "High Frequency Program: Application Guidance for Functional Confirmation and Fragility," dated September 17, 2015 (ML15218A569) 1O. NRC Letter, Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 1O of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated October 27, 2015 (ML15194A015)
: 6) on page 3 of Enclosure 2, Limerick Generating Station, Units 1 and 2 is to conduct a limited scope High Frequency Evaluation (Confirmation).
On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued a Request for Information per 10 CFR 50.54(f) (Reference 1) to all power reactor licensees. The required response section of Enclosure 1 of Reference 1 indicated that licensees should provide a Seismic Hazard Evaluation and Screening Report within 1.5 years from the date of the letter for Central and Eastern United States (CEUS) nuclear power plants. By NRC letter dated May 7, 2013 (Reference 2), the date to submit the report was extended to March 31, 2014.
Within the May 9, 2014 letter (Reference 6), the NRC acknowledged that these limited scope evaluations will require additional development of the assessment process. By Reference 8, the Nuclear Energy Institute (NEI) submitted an Electric Power Research Institute (EPRI) report entitled, High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396) for NRC review and endorsement.
By letter dated May 9, 2014 (Reference 6), the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation report for Limerick Generating Station, Units 1 and 2 submitted on March 31, 2014 (Reference 5). In accordance with the Screening, Prioritization, and Implementation Details report (SPID) (References 3 and 4), and Augmented Approach Guidance (Reference 2), the reevaluated seismic hazard is used to determine if additional seismic risk evaluations are warranted for a plant. Specifically, the reevaluated horizontal Ground Motion Response Spectrum (GMRS) at the control point elevation is compared to the existing Safe Shutdown Earthquake (SSE) or Individual Plant Examination for External Events (IPEEE) High Confidence of Low Probability of Failure (HCLPF) Spectrum (IHS) to determine if a plant is required to perform a high frequency confirmation evaluation. As noted in the May 9, 2014 letter from the NRC (Reference 6) on page 3 of Enclosure 2, Limerick Generating Station, Units 1 and 2 is to conduct a limited scope High Frequency Evaluation (Confirmation).
NRC endorsement U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 28, 2016 Page 3 was provided by Reference
Within the May 9, 2014 letter (Reference 6), the NRC acknowledged that these limited scope evaluations will require additional development of the assessment process. By Reference 8, the Nuclear Energy Institute (NEI) submitted an Electric Power Research Institute (EPRI) report entitled, High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396) for NRC review and endorsement. NRC endorsement
: 9. Reference 10 provided the NRC final seismic hazard evaluation screening determination results and the associated schedules for submittal of the remaining seismic hazard evaluation activities.
 
The High Frequency Evaluation Confirmation Report for Limerick Generating Station, Units 1 and 2, provided in the enclosure to this letter, shows that all high frequency susceptible equipment evaluated within the scoping requirements and using evaluation criteria of Reference 8 for seismic demands and capacities, are acceptable.
U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 28, 2016 Page 3 was provided by Reference 9. Reference 10 provided the NRC final seismic hazard evaluation screening determination results and the associated schedules for submittal of the remaining seismic hazard evaluation activities.
Therefore, no additional modifications or evaluations are necessary.
The High Frequency Evaluation Confirmation Report for Limerick Generating Station, Units 1 and 2, provided in the enclosure to this letter, shows that all high frequency susceptible equipment evaluated within the scoping requirements and using evaluation criteria of Reference 8 for seismic demands and capacities, are acceptable. Therefore, no additional modifications or evaluations are necessary.
This transmittal completes the scope of work described in Section 4.2 of Reference 5 for Limerick Generating Station, Units 1 and 2. This letter closes the associated regulatory commitment contained in Enclosure 2 of Reference 5 for Limerick Generating Station, Units 1 and 2. This letter contains no new regulatory commitments.
This transmittal completes the scope of work described in Section 4.2 of Reference 5 for Limerick Generating Station, Units 1 and 2.
This letter closes the associated regulatory commitment contained in Enclosure 2 of Reference 5 for Limerick Generating Station, Units 1 and 2.
This letter contains no new regulatory commitments.
If you have any questions regarding this report, please contact Ronald Gaston at 630-657-3359.
If you have any questions regarding this report, please contact Ronald Gaston at 630-657-3359.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 28 1 h day of November 2016. Respectfully submitted, James Barstow Director -Licensing  
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 281h day of November 2016.
& Regulatory Affairs Exelon Generation Company, LLC  
Respectfully submitted,
    ~kf:-
James Barstow Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC


==Enclosure:==
==Enclosure:==
Limerick Generating Station, Units 1 and 2 - Seismic High Frequency Evaluation Confirmation Report cc:    NRC Regional Administrator - Region I NRC Project Manager, NRA - Limerick Station NRC Senior Resident Inspector - Limerick Station Mr. Brett A. Titus, NRR/JLD/JCBB, NRC Mr. Stephen M. Wyman, NRR/JLD/JHMB, NRC Mr. Frankie G. Vega, NRR/JLD/JHMB, NRC Director, Bureau of Radiation Protection - Pennsylvania Department of Environmental Resources R. R. Janati, Chief, Division of Nuclear Safety, Pennsylvania Department of Environmental Protection, Bureau of Radiation Protection
Enclosure Limerick Generating Station, Units 1 and 2 Seismic High Frequency Evaluation Confirmation Report (11 O pages)


Limerick Generating Station, Units 1 and 2 -Seismic High Frequency Evaluation Confirmation Report cc: NRC Regional Administrator
HIGH FREQUENCY CONFIRMATION REPORT IN RESPONSE TO NEAR TERM TASK FORCE (NTIF) 2.1 RECOMMENDATION for the LIMERICK GENERATING STATION, UNITS 1 AND 2 3146 Sanatoga Rd, Pottstown, PA 19464 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353 Correspondence No.: RS-16-177 Exelon Exelon Generation Company, LLC (Exelon)
-Region I NRC Project Manager, NRA -Limerick Station NRC Senior Resident Inspector
PO Box 805398 Chicago, IL 60680-5398 Prepared by:
-Limerick Station Mr. Brett A. Titus, NRR/JLD/JCBB, NRC Mr. Stephen M. Wyman, NRR/JLD/JHMB, NRC Mr. Frankie G. Vega, NRR/JLD/JHMB, NRC Director, Bureau of Radiation Protection
Stevenson & Associates 1661 Feehanvllle Drive, Suite 150 Mount Prospect, IL 60056 Report Number: 15C4345-RPT-002, Rev. O Printed Name                     Signature        ~
-Pennsylvania Department of Environmental Resources R. R. Janati, Chief, Division of Nuclear Safety, Pennsylvania Department of Environmental Protection, Bureau of Radiation Protection Enclosure Limerick Generating Station, Units 1 and 2 Seismic High Frequency Evaluation Confirmation Report (11 O pages)
Preparer:        F. Ganatra                                   10/27/2016 Reviewer:        M. Delaney                                   10/27/2016 Approver:        M. Delaney                                   10/27/2016 Lead Responsible Engineer. Lll!M ~=='='                                        11/t-,i!D/~
HIGH FREQUENCY CONFIRMATION REPORT IN RESPONSE TO NEAR TERM TASK FORCE (NTIF) 2.1 RECOMMENDATION for the LIMERICK GENERATING STATION, UNITS 1 AND 2 3146 Sanatoga Rd, Pottstown, PA 19464 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353 Correspondence No.: RS-16-177 Preparer:
BranchManaser:     ~\U.D~                                              \\~~l \Cc.
Reviewer: Approver: Exelon Exelon Generation Company, LLC (Exelon) PO Box 805398 Chicago, IL 60680-5398 Prepared by: Stevenson  
Senior Manager   ~                          --1~~_,q._...;:::o._ __
& Asso ci ate s 1661 Feehanvllle Drive, Suite 150 Mount Pro s pect, IL 600 5 6 Report Number: 1 5C4345-RPT-0 02, Rev. O Printed Name F. Ganatra M. Delaney M. Delaney Signature Lead Responsible Engineer.
Design En1lneerln1: -S-,...., &r1 11tt 1                                   "I er/ 1b Corporate Acceptance: \iSSru, S. C lAr \c.                                 11/.,/20ue
Lll!M BranchManaser:
 
Senior Manager
Document ID: 15C4345-RPT-002
__ _ Design En1lneerln1: -S-,...., &r1 1 11tt Corporate Acceptance
 
: \iSSru, S. C lAr \c. 10/27/2016 10/27/2016 10/27/2016
==Title:==
\Cc. "I er/ 1 b 11/.,/20ue Document ID: 15C4345-RPT-002 Title: High Frequency Confirmation Report for Limerick Generating Station, Unit 1 and 2 in Response to Near Term Task Force (NTTF) 2.1 Recommendation Document Type: Criteria D Interface D Report Specification D Other D Drawing D Project Name: Limerick, Unit 1 and 2 High Frequency Confirmation Job No.: 15C4345 ,,,,..,, Client: This document has been prepared under the guidance of the S&A Quality Assurance Program Manual, Revision 18 and project requirements:
High Frequency Confirmation Report for Limerick Generating Station, Unit 1 and 2 in Response to Near Term Task Force (NTTF) 2.1 Recommendation Document Type:
For Owner's Acceptance Review (Rev. 0) Date: 10/27 /2016 Originated by: F. Ganatra Date: 10/27 /2016 Checked by: M. Delaney Date: 10/27 /2016 Approved by: M. Delaney Revision Record: Revision Originated by/ Checked by/ Approved by/ Description of Revision No. Date Date Stevenson
Criteria D         Interface D Report ~    Specification D Other D         Drawing D Project Name:
& Associates Date DOCUMENT APPROVAL SHEET Figure 2.8 PROJECT NO. 15C4345 Executive Summary 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 The purpose of this report is to provide information as requested by the Nuclear Regulatory Commission (NRC) in its March 12, 2012 letter issued to all power reactor licensees and holders of construction permits in active or deferred status [l]. In particular, this report provides information requested to address the High Frequency Confirmation requirements of Item (4), Enclosure 1, Recommendation 2.1: Seismic, of the March 12, 2012 letter [1]. Following the accident at the Fukushima Dai-ichi nuclear power plant resulting from the March 11, 2011, Great Tohoku Earthquake and subsequent tsunami, the Nuclear Regulatory Commission (NRC} established a Near Term Task Force (NTIF) to conduct a systematic review of NRC processes and regulations and to determine if the agency should make additional improvements to its regulatory system. The NTIF developed a set of recommendations
Limerick, Unit 1 and 2 High Frequency Confirmation Job No.: 15C4345 Client:
[15] intended to clarify and strengthen the regulatory framework for protection against natural phenomena.
            ~
Subsequently, the NRC issued a 50.54(f} letter on March 12, 2012 [1], requesting information to assure that these recommendations are addressed by all U.S. nuclear power plants. The 50.54(f} letter requests that licensees and holders of construction permits under 10 CFR Part 50 reevaluate the seismic hazards at their sites against present-day NRC requirements and guidance.
Exelon ~
Included in the 50.54(f} letter was a request that licensees' perform a "confirmation, if necessary, that SSCs, which may be affected by high-frequency ground motion, will maintain their functions important to safety." EPRI 1025287, "Seismic Evaluation Guidance:
This document has been prepared under the guidance of the S&A Quality Assurance Program Manual, Revision 18 and project requirements:
Screening, Prioritization and Implementation Details (SPID} for the resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic" [6] provided screening, prioritization, and implementation details to the U.S. nuclear utility industry for responding to the NRC 50.54(f} letter. This report was developed with NRC participation and was subsequently endorsed by the NRC. The SPID included guidance for determining which plants should perform a High Frequency Confirmation and identified the types of components that should be evaluated in the evaluation.
For Owner's Acceptance Review (Rev. 0)
Subsequent guidance for performing a High Frequency Confirmation was provided in EPRI 3002004396, "High Frequency Program, Application Guidance for Functional Confirmation and Fragility Evaluation," [8] and was endorsed by the NRC in a letter dated September 17, 2015 [3]. Final screening identifying plants needing to perform a High Frequency Confirmation was provided by NRC in a letter dated October 27, 2015 [2]. This report describes the High Frequency Confirmation evaluation undertaken for Limerick Generating Station, Unit 1 and 2 (LIM). The objective of this report is to provide summary information describing the High Frequency Confirmation evaluations and results. The level of detail provided in the report is intended to enable NRC to understand the inputs used, the evaluations performed, and the decisions made as a result of the evaluations.
Date: 10/27/2016 Originated by: F. Ganatra       fU- 4~
EPRI 3002004396
Date: 10/27/2016 Checked by: M. Delaney         ~/t(~
[8] is used for the LIM engineering evaluations described in this report. In accordance with Reference
Date: 10/27/2016 Approved by: M. Delaney         ~ft(~
[8], the following topics are addressed in the subsequent sections of this report:
Revision Record:
Revision       Originated by/ Checked by/   Approved by/   Description of Revision No.           Date           Date         Date DOCUMENT                   PROJECT NO.
APPROVAL SHEET                     15C4345 Figure 2.8 Stevenson & Associates
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Executive Summary The purpose of this report is to provide information as requested by the Nuclear Regulatory Commission (NRC) in its March 12, 2012 letter issued to all power reactor licensees and holders of construction permits in active or deferred status [l]. In particular, this report provides information requested to address the High Frequency Confirmation requirements of Item (4), Enclosure 1, Recommendation 2.1: Seismic, of the March 12, 2012 letter [1].
Following the accident at the Fukushima Dai-ichi nuclear power plant resulting from the March 11, 2011, Great Tohoku Earthquake and subsequent tsunami, the Nuclear Regulatory Commission (NRC}
established a Near Term Task Force (NTIF) to conduct a systematic review of NRC processes and regulations and to determine if the agency should make additional improvements to its regulatory system . The NTIF developed a set of recommendations [15] intended to clarify and strengthen the regulatory framework for protection against natural phenomena. Subsequently, the NRC issued a 50.54(f} letter on March 12, 2012 [1], requesting information to assure that these recommendations are addressed by all U.S. nuclear power plants. The 50.54(f} letter requests that licensees and holders of construction permits under 10 CFR Part 50 reevaluate the seismic hazards at their sites against present-day NRC requirements and guidance. Included in the 50.54(f} letter was a request that licensees' perform a "confirmation, if necessary, that SSCs, which may be affected by high-frequency ground motion, will maintain their functions important to safety."
EPRI 1025287, "Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details (SPID} for the resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic" [6]
provided screening, prioritization, and implementation details to the U.S. nuclear utility industry for responding to the NRC 50.54(f} letter. This report was developed with NRC participation and was subsequently endorsed by the NRC. The SPID included guidance for determining which plants should perform a High Frequency Confirmation and identified the types of components that should be evaluated in the evaluation.
Subsequent guidance for performing a High Frequency Confirmation was provided in EPRI 3002004396, "High Frequency Program, Application Guidance for Functional Confirmation and Fragility Evaluation," [8] and was endorsed by the NRC in a letter dated September 17, 2015 [3]. Final screening identifying plants needing to perform a High Frequency Confirmation was provided by NRC in a letter dated October 27, 2015 [2].
This report describes the High Frequency Confirmation evaluation undertaken for Limerick Generating Station, Unit 1 and 2 (LIM). The objective of this report is to provide summary information describing the High Frequency Confirmation evaluations and results. The level of detail provided in the report is intended to enable NRC to understand the inputs used, the evaluations performed, and the decisions made as a result of the evaluations.
EPRI 3002004396 [8] is used for the LIM engineering evaluations described in this report. In accordance with Reference [8], the following topics are addressed in the subsequent sections of this report:
* Process of selecting components and a list of specific components for high-frequency confirmation
* Process of selecting components and a list of specific components for high-frequency confirmation
* Estimation of a vertical ground motion response spectrum (GMRS} Page 3of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177
* Estimation of a vertical ground motion response spectrum (GMRS}
* Es timation of in-cabinet seismic demand for subject components
Page 3of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177
* Estimation of in-cabinet seismic demand for subject components
* Estimation of in-cabinet seismic capacity for subject components
* Estimation of in-cabinet seismic capacity for subject components
* Summary of subject components' high-frequency evaluations Page 4 of 110 1 Introduction
* Summary of subject components' high-frequency evaluations Page 4 of 110


===1.1 PURPOSE===
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 1  Introduction 1.1 PURPOSE The purpose of this report is to provide information as requested by the NRC in its March 12, 2012 S0.54(f) letter issued to all power reactor licensees and holders of construction permits in active or deferred status [1]. In particular, this report provides requested information to address the High Frequency Confirmation requirements of Item (4), Enclosure 1, Recommendation 2.1:
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 The purpose of this report is to provide information as requested by the NRC in its March 12, 2012 S0.54(f) letter issued to all power reactor licensees and holders of construction permits in active or deferred status [1]. In particular, this report provides requested information to address the High Frequency Confirmation requirements of Item (4), Enclosure 1, Recommendation 2.1: Seismic, ofthe March 12, 2012 letter [1].  
Seismic, ofthe March 12, 2012 letter [1].


==1.2 BACKGROUND==
==1.2 BACKGROUND==
Line 84: Line 107:
Following the accident at the Fukushima Dai-ichi nuclear power plant resulting from the March 11, 2011, Great Tohoku Earthquake and subsequent tsunami, the Nuclear Regulatory Commission (NRC) established a Near Term Task Force (NTIF) to conduct a systematic review of NRC processes and regulations and to determine if the agency should make additional improvements to its regulatory system. The NTIF developed a set of recommendations intended to clarify and strengthen the regulatory framework for protection against natural phenomena.
Following the accident at the Fukushima Dai-ichi nuclear power plant resulting from the March 11, 2011, Great Tohoku Earthquake and subsequent tsunami, the Nuclear Regulatory Commission (NRC) established a Near Term Task Force (NTIF) to conduct a systematic review of NRC processes and regulations and to determine if the agency should make additional improvements to its regulatory system. The NTIF developed a set of recommendations intended to clarify and strengthen the regulatory framework for protection against natural phenomena.
Subsequently, the NRC issued a 50.54(f) letter on March 12, 2012 [1], requesting information to assure that these recommendations are addressed by all U.S. nuclear power plants. The 50.54(f) letter requests that licensees and holders of construction permits under 10 CFR Part 50 reevaluate the seismic hazards at their sites against present-day NRC requirements and guidance.
Subsequently, the NRC issued a 50.54(f) letter on March 12, 2012 [1], requesting information to assure that these recommendations are addressed by all U.S. nuclear power plants. The 50.54(f) letter requests that licensees and holders of construction permits under 10 CFR Part 50 reevaluate the seismic hazards at their sites against present-day NRC requirements and guidance.
Included in the 50.54(f) letter was a request that licensees' perform a "confirmation, if necessary, that SSCs, which may be affected by high-frequency ground motion, will maintain their functions important to safety." EPRI 1025287, "Seismic Evaluation Guidance:
Included in the 50.54(f) letter was a request that licensees' perform a "confirmation, if necessary, that SSCs, which may be affected by high-frequency ground motion, will maintain their functions important to safety."
Screening, Prioritization and Implementation Details (SPID) for the resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic" [6] provided screening, prioritization, and implementation details to the U.S. nuclear utility industry for responding to the NRC 50.54(f) letter. This report was developed with NRC participation and is endorsed by the NRC. The SPID included guidance for determining which plants should perform a High Frequency Confirmation and identified the types of components that should be evaluated in the evaluation. Subsequent guidance for performing a High Frequency Confirmation was provided in EPRI 3002004396, "High Frequency Program, Application Guidance for Functional Confirmation and Fragility Evaluation," [8] and was endorsed by the NRC in a letter dated September 17, 2015 [3]. Final screening identifying plants needing to perform a High Frequency Confirmation was provided by NRC in a letter dated October 27, 2015 [2]. On March 31, 2014, LIM submitted a reevaluated seismic hazard to the NRC as a part of the Seismic Hazard and Screening Report [4]. By letter dated October 27, 2015 [2], the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation.
EPRI 1025287, "Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details (SPID) for the resolution of Fukushima Near-Term Task Force Recommendation 2.1:
This report describes the High Frequency Confirmation evaluation undertaken for LIM using the methodologies in EPRI 3002004396, "High Frequency Program, Application Guidance for Page 5of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 F unctional Confirmation and Fragility Evaluation," as endorsed by the NRC in a letter dated September 17, 2015 (3]. The objective of this report is to provide summary information describing the High Frequency Confirmation evaluations and results. The level of detail provided in the report is intended to enable NRC to understand the inputs used, the evaluations performed, and the conclusions made as a result of the evaluations.
Seismic" [6] provided screening, prioritization, and implementation details to the U.S. nuclear utility industry for responding to the NRC 50.54(f) letter. This report was developed with NRC participation and is endorsed by the NRC. The SPID included guidance for determining which plants should perform a High Frequency Confirmation and identified the types of components that should be evaluated in the evaluation .
Subsequent guidance for performing a High Frequency Confirmation was provided in EPRI 3002004396, "High Frequency Program, Application Guidance for Functional Confirmation and Fragility Evaluation," [8] and was endorsed by the NRC in a letter dated September 17, 2015 [3].
Final screening identifying plants needing to perform a High Frequency Confirmation was provided by NRC in a letter dated October 27, 2015 [2].
On March 31, 2014, LIM submitted a reevaluated seismic hazard to the NRC as a part of the Seismic Hazard and Screening Report [4]. By letter dated October 27, 2015 [2], the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation.
This report describes the High Frequency Confirmation evaluation undertaken for LIM using the methodologies in EPRI 3002004396, "High Frequency Program, Application Guidance for Page 5of110


===1.3 APPROACH===
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Functional Confirmation and Fragility Evaluation," as endorsed by the NRC in a letter dated September 17, 2015 (3] .
EPRI 3002004396
The objective of this report is to provide summary information describing the High Frequency Confirmation evaluations and results. The level of detail provided in the report is intended to enable NRC to understand the inputs used, the evaluations performed, and the conclusions made as a result of the evaluations.
[8] is used for the LIM engineering evaluations described in this report. Section 4.1 of Reference
1.3 APPROACH EPRI 3002004396 [8] is used for the LIM engineering evaluations described in this report. Section 4.1 of Reference [8] provided general steps to follow for the high frequency confirmation component evaluation. Accordingly, the following topics are addressed in the subsequent sections of this report:
[8] provided general steps to follow for the high frequency confirmation component evaluation.
Accordingly, the following topics are addressed in the subsequent sections of this report:
* LIM SSE and GMRS Information
* LIM SSE and GMRS Information
* Selection of components and a list of specific components for high-frequency confirmation
* Selection of components and a list of specific components for high-frequency confirmation
Line 98: Line 123:
* Estimation of seismic capacity for subject components
* Estimation of seismic capacity for subject components
* Summary of subject components' high-frequency evaluations
* Summary of subject components' high-frequency evaluations
* Summary of Results 1.4 PLANT SCREENING LIM submitted reevaluated seismic hazard information including GMRS and seismic hazard information to the NRC on March 31, 2014 (4]. In a letter dated November 6, 2015, the NRC staff concluded that the submitted GMRS adequately characterizes the reevaluated seismic hazard forthe LIM site for 2.1 Seismic (14]. The NRC final screening determination letter concluded
* Summary of Results 1.4 PLANT SCREENING LIM submitted reevaluated seismic hazard information including GMRS and seismic hazard information to the NRC on March 31, 2014 (4]. In a letter dated November 6, 2015, the NRC staff concluded that the submitted GMRS adequately characterizes the reevaluated seismic hazard forthe LIM site for 2.1 Seismic (14].
[2] that the LIM GMRS to SSE comparison resulted in a need to perform a High Frequency Confirmation in accordance with the screening criteria in the SPID [6]. 1.5 REPORT DOCUMENTATION Section 2 describes the selection of devices. The identified devices are evaluated in Reference (17] for the seismic demand specified in Section 3 using the evaluation criteria discussed in Section 4. The overall conclusion is discussed in Section 5. Table B-1 lists the devices identified in Section 2 and provides the results of the evaluations performed in accordance with Section 3 and Section 4. Page 6 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 2 Selection of Components for High-Frequency Screening The fundamental objective of the high frequency confirmation review is to determine whether the occurrence of a seismic event could cause credited equipment to fail to perform as necessary.
The NRC final screening determination letter concluded [2] that the LIM GMRS to SSE comparison resulted in a need to perform a High Frequency Confirmation in accordance with the screening criteria in the SPID [6].
An optimized evaluation process is applied that focuses on achieving a safe and stable plant state following a seismic event. As described in Reference
1.5 REPORT DOCUMENTATION Section 2 describes the selection of devices. The identified devices are evaluated in Reference (17] for the seismic demand specified in Section 3 using the evaluation criteria discussed in Section 4. The overall conclusion is discussed in Section 5.
[8], this state is achieved by confirming that key plant safety functions critical to immediate plant safety are preserved (reactor trip, reactor vessel inventory and pressure control, and core cooling) and that the plant operators have the necessary power available to achieve and maintain this state immediately following the seismic event (AC/DC power support systems). Within the applicable functions, the components that would need a high frequency confirmation are contact control devices subject to intermittent states in seal-in or lockout circuits.
Table B-1 lists the devices identified in Section 2 and provides the results of the evaluations performed in accordance with Section 3 and Section 4.
Accordingly, the objective of the review as stated in Section 4.2.1 of Reference (8] is to determine if seismic induced high frequency relay chatter would prevent the completion of the following key functions.
Page 6 of 110


===2.1 REACTOR===
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 2      Selection of Components for High-Frequency Screening The fundamental objective of the high frequency confirmation review is to determine whether the occurrence of a seismic event could cause credited equipment to fail to perform as necessary. An optimized evaluation process is applied that focuses on achieving a safe and stable plant state following a seismic event. As described in Reference [8], this state is achieved by confirming that key plant safety functions critical to immediate plant safety are preserved (reactor trip, reactor vessel inventory and pressure control, and core cooling) and that the plant operators have the necessary power available to achieve and maintain this state immediately following the seismic event (AC/DC power support systems) .
TRIP/SCRAM The reactor trip/SCRAM function is identified as a key function in Reference
Within the applicable functions, the components that would need a high frequency confirmation are contact control devices subject to intermittent states in seal-in or lockout circuits. Accordingly, the objective of the review as stated in Section 4.2.1 of Reference (8] is to determine if seismic induced high frequency relay chatter would prevent the completion of the following key functions.
[8] to be considered in the High Frequency Confirmation.
2.1     REACTOR TRIP/SCRAM The reactor trip/SCRAM function is identified as a key function in Reference [8] to be considered in the High Frequency Confirmation. The same report also states that "the design requirements preclude the application of seal-in or lockout circuits that prevent reactor trip/SCRAM functions" and that "No high-frequency review of the reactor trip/SCRAM systems is necessary."
The same report also states that "the design requirements preclude the application of seal-in or lockout circuits that prevent reactor trip/SCRAM functions" and that "No high-frequency review of the reactor trip/SCRAM systems is necessary." 2.2 REACTOR VESSEL INVENTORY CONTROL The reactor coolant system/reactor vessel inventory control systems were reviewed for contact control devices in seal-in and lockout (SILO) circuits that would create a Loss of Coolant Accident (LOCA). The focus of the review was contact control devices that could lead to a significant leak path. Check valves in series with active valves would prevent significant leaks due to misoperation of the active valve; therefore, SILO circuit reviews were not required for those active valves. The process/criteria for assessing potential reactor coolant leak path valves is to review all P&ID's attached to the Reactor Coolant System (RCS) and include all active isolation valves and any active second valve upstream or downstream that is assumed to be required to be closed during normal operation or close upon an initiating event (Loss of Coolant Accident "LOCA" or Seismic).
2.2     REACTOR VESSEL INVENTORY CONTROL The reactor coolant system/reactor vessel inventory control systems were reviewed for contact control devices in seal-in and lockout (SILO) circuits that would create a Loss of Coolant Accident (LOCA). The focus of the review was contact control devices that could lead to a significant leak path. Check valves in series with active valves would prevent significant leaks due to misoperation of the active valve; therefore, SILO circuit reviews were not required for those active valves.
A table with the valves and associated P&ID is included in Table B-2 of this report. Manual valves that are normally closed are assumed to remain closed and a second simple check valve is assumed to function and not be a Multiple Spurious Failure. Page 7 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 On BWR's the instrument lines that are 1" or less, in general, are assumed to have restricting orifices that are designed to mitigate any leakage due to make up. Table B-2 contains a list of valves analyzed and based on the analysis detailed below, there are no moving contact control devices which could create a LOCA due to chatter-induced sustained valve misalignment, and thus no devices were selected for this category.
The process/criteria for assessing potential reactor coolant leak path valves is to review all P&ID's attached to the Reactor Coolant System (RCS) and include all active isolation valves and any active second valve upstream or downstream that is assumed to be required to be closed during normal operation or close upon an initiating event (Loss of Coolant Accident "LOCA" or Seismic).
For valves in Table B-2 that were identified as not requiring evaluation, the justification is provided in the Notes section of the table and is in accordance with guidance criteria.
A table with the valves and associated P&ID is included in Table B-2 of this report.
Nuclear Steam Supply Shutoff Valves Reactor Head Vent Valves HV-041-lFOOl, HV-041-1F002, HV-041-2F001, HV-041-2F002 These two Unit 1 valves [HV-041-lFOOl, HV-041-1F002]
Manual valves that are normally closed are assumed to remain closed and a second simple check valve is assumed to function and not be a Multiple Spurious Failure.
are normally closed and in series with one another [23]. Note 39 on the P&ID stipulates HV-041-1F002 is "disabled by locking open the circuit breaker and using administrative controls to assure that the valve is maintained in a closed positon when not in use" [24]. Because HV-041-1F002 is closed, depowered, and blocking flow through HV-041-lFOOl, contact chatter in the control circuits of either valve is irrelevant.
Page 7 of 110
Note 50 on the Unit 2 P&ID makes the same statement
[25, 26], thus this reasoning applies to the Unit 2 valves HV-041-2F001, HV-041-2F002 as well. Auto Depressurization Valves PSV-041-1F013E/H/K/M/S, PSV-041-2F013E/H/K/M/S Electrical control for the solenoid-operated pilot valves is via relays B21C-K6A/C/E/G and K9A/C/E/G
[27, 28, 29, 30]. These relays are controlled by the High Drywell Pressure I Reactor Pressure Vessel (RPV) Low Level Logic and the Residual Heat Removal (RHR) Pump Pressure relays B21C-K10A/C/E/G
[31, 32]. The RHR Pump Pressure relays do not seal-in [33, 34] and, based on initial conditions at the time of the event, would block any inadvertent seal-in of the High Drywell Pressure I RPV Low Level Logic. Thus there is no SILO relays in this logic which could cause the Auto Depressurization Valves to remain open following a seismic event. Safety Relief Valves PSV-041-1 F013A/B/C/D/F/G/l/L/N, PSV-041-2F013A/B/C/D/F/G/l/L/N Electrical control for the solenoid-operated pilot valves is via a rugged hand control switch. There are no chatter sensitive contact devices involved in the control of these valves [35, 36, 37, 38]. Main Steam Isolation Valves HV-041-1F022A/B/C/D, HV-041-1F028A/B/C/O, HV-041-2F022A/B/C/D, HV-041-2F028A/B/C/D Electrical control for the solenoid-operated pilot valves is via relays B21H-Kl8A/B/C/D.
These relays are slaves to B21H-Kl4A/B/C/D isolation logic relays [39, 40, 41, 42]. These relays are energized for at-power operation and de-energized to close the valves [43, 44, 45, 46]. In the energized state B21H-K14A/B/C/D are sealed in and any chatter in the control logic would break the seal-in and close the valves. This action is a desired response to the seismic event and for this reason chatter is acceptable and no contact devices in this circuit meet the selection criteria.
Page 8of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Main Steam Line Equalizer Valves HV-C-041-1F020, HV-C-041-2F020 These normally-open motor-operated valves are controlled by hand switches only [47, 48, 49]. Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch. Thus these valves are not affected by SILO. Main Steam Line Drain Valves HV-041-1F016, HV-041-1F019, HV-041-2F016, HV-041-2F019 The opening of normally-closed motor-operated valves HV-041-1F016/
HV-041-2F016 is commanded by a rugged hand switch with no seal-in contacts [SO, 51]. This valve opening control is insensitive to contact chatter and thus the valve will remain closed after the seismic event. As stated in Table B-2, HV-041-1F019/HV-041-2F019 do not need to be analyzed provided HV-041-1F016/HV-041-2F016 remain closed. Reactor Water Clean-Up Valves Reactor Water Clean-Up Flow Control Valves HV-044-lFlOS, HV-044-2F105; Bottom Head Drain Flow Control Valves HV-044-lFlOO, HV-044-2F100 These normally-open motor-operated valves are controlled by hand switches only [52, 53]. Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch. Thus these valves are not affected by SILO. Reactor Water Clean-Up Isolation Valves HV-044-lFOOl, HV-044-1F004, HV-044-2F001, HV-044-2F004; Bottom Head Drain Flow Control Valves These are normally-open motor-operated valves which close upon an isolation signal. Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch or isolation relay B21H-K24A/B
[54, 55, 56, 57]. These relays are energized for at-power operation and de-energized to close the valves [58, 59, 60, 61]. In the energized state B21H-K24A/B are sealed in and any chatter in the control logic would break the seal-in and close the valves. This action is a desired response to the seismic event and for this reason chatter is acceptable and no contact devices in this circuit meet the selection criteria.
Reactor Core Isolation Cooling Valves Reactor Core Isolation Cooling Steam Supply Line Isolation Valves HV-049-lFOOl, HV-049-lFOOB, HV-049-2F007, HV-049-2FOOB These normally-open motor-operated valves are required to remain open to supply steam to the RCIC turbine. There is no seal-in in the opening circuit, and closure, if needed, is not blocked by SILO [62, 63, 64, 65]. Inadvertent closure of these valves is covered in the RCIC chatter analysis in Section 5.3.7 of Ref. [18]. Residual Heat Removal Valves Testable Check Valves HV-051-1F041A/B/C/D, HV-051-lFOSOA/B, HV-051-2F041A/8/C/D, HV-051-2F050A/B These solenoid-operated valves are controlled by a rugged, normally open push button [66, 67, 68, 69, 70, 71, 72, 73, 74, 75]. There are no SILO devices that would prevent the normal operation of these check valves. Page 9 of 110 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 RHR Injection Valves HV-051-1F017A/B/C/D, HV-051-2F017A/B/C/D; RHR Shutdown Cooling Injection Valves HV-051-1F015A/B, HV-051-2F015A/B Since the testable check valves are not chatter sensitive and can be credited to remain closed, these downstream motor operated valves do not need to be analyzed per the notes in Table B-2. RHR Shutdown Cooling Isolation Valves HV-051-1F008, HV-051-2F008; RHR Shutdown Cooling Suction Valves HV-051-1F009, HV-051-2F009 These normally-closed motor-operated valves are opened via a normally-open control switch and relay permissive.
The valves can be closed manually via the control switch and automatically via an isolation signal. Sympathetic chatter on B21H-K29A/B and 42/0 auxiliary contact could cause valve to open [76, 77, 78, 79], however the low reactor pressure permissive in control logic would prevent seal-in of B21H-K29A/B
[58, 59, 60, 61]. After the period of strong shaking the closed contact of B21H-K29A/B (isolation signal) would command these valves to reclose. Because there is no seal-in and the valves reclose without operator intervention, chatter is acceptable and no contact devices in this circuit meet the selection criteria.
Core Spray Valves Testable Check Valves HV-052-1F006A/B, HV-052-2F006A/B These solenoid-operated valves are controlled by a rugged, normally open push button [80, 81, 82, 83]. There are no SILO devices that would prevent the normal operation of these check valves. Core Spray Outboard Check Valves HV-052-108, HV-052-208; Core Spray Inboard Motor Operated Valve HV-052-1F005, HV-052-2F005 Since the testable check valves are not chatter sensitive and can be credited to remain closed, these downstream motor operated valves do not need to be analyzed per the notes in Table B-2. High Pressure Core Injection Valves High Pressure Core Injection Steam Supply Line Isolation Valves HV-055-1F002, HV-055-1F003, HV-055-2F002, HV-055-2F003 These normally-open motor-operated valves supply steam to the HPCI turbine. The opening circuit is controlled by a rugged hand switch and permissive from E41A-K50B/D
[84, 85, 86, 87]. There is no seal-in in the opening circuit. The closing circuit is controlled manually by a rugged hand switch or automatically via the isolation relay E41A-K50B/D
[88 , 89]. Any chatter in the isolation logic would seal-in E41A-K50B/D and close the valves. Since RCIC, not HPCI, is credited for core cooling this seal-in causing valve closure is not a selection criterion. There is no SILO which would prevent closure of these valves and thus no contact devices in this circuit meet the selection criteria.
Page10of110 


===2.3 REACTOR===
15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 On BWR's the instrument lines that are 1" or less, in general, are assumed to have restricting orifices that are designed to mitigate any leakage due to make up.
VESSEL PRESSURE CONTROL 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 The reactor vessel pressure control function is identified as a key function in Reference
Table B-2 contains a list of valves analyzed and based on the analysis detailed below, there are no moving contact control devices which could create a LOCA due to chatter-induced sustained valve misalignment, and thus no devices were selected for this category. For valves in Table B-2 that were identified as not requiring evaluation, the justification is provided in the Notes section of the table and is in accordance with guidance criteria.
[8) to be considered in the High Frequency Confirmation.
Nuclear Steam Supply Shutoff Valves Reactor Head Vent Valves HV-041-lFOOl, HV-041-1F002, HV-041-2F001, HV-041-2F002 These two Unit 1 valves [HV-041-lFOOl, HV-041-1F002] are normally closed and in series with one another [23]. Note 39 on the P&ID stipulates HV-041-1F002 is "disabled by locking open the circuit breaker and using administrative controls to assure that the valve is maintained in a closed positon when not in use" [24]. Because HV-041-1F002 is closed, depowered, and blocking flow through HV-041-lFOOl, contact chatter in the control circuits of either valve is irrelevant. Note 50 on the Unit 2 P&ID makes the same statement [25, 26], thus this reasoning applies to the Unit 2 valves HV-041-2F001, HV-041-2F002 as well.
The same report also states that "required post event pressure control is typically provided by passive devices" and that "no specific high frequency component chatter review is required for this function." 2.4 CORE COOLING The core cooling systems were reviewed for contact control devices in seal-in and lockout circuits that would prevent at least a single train of non-AC power driven decay heat removal from functioning.
Auto Depressurization Valves PSV-041-1F013E/H/K/M/S, PSV-041-2F013E/H/K/M/S Electrical control for the solenoid-operated pilot valves is via relays B21C-K6A/C/E/G and B21C-K9A/C/E/G [27, 28, 29, 30]. These relays are controlled by the High Drywell Pressure I Reactor Pressure Vessel (RPV) Low Level Logic and the Residual Heat Removal (RHR) Pump Pressure relays B21C-K10A/C/E/G [31, 32]. The RHR Pump Pressure relays do not seal-in [33, 34] and, based on initial conditions at the time of the event, would block any inadvertent seal-in of the High Drywell Pressure I RPV Low Level Logic. Thus there is no SILO relays in this logic which could cause the Auto Depressurization Valves to remain open following a seismic event.
Limerick credits their steam turbine-driven Reactor Core Isolation Cooling (RCIC} Pump to provide core decay-heat cooling. The selection of contact devices for the Safety Relief Valves (SRVs) overlaps with the RCS/Reactor Vessel Inventory Control Category.
Safety Relief Valves PSV-041-1 F013A/B/C/D/F/G/l/L/N, PSV-041-2F013A/B/C/D/F/G/l/L/N Electrical control for the solenoid-operated pilot valves is via a rugged hand control switch. There are no chatter sensitive contact devices involved in the control of these valves [35, 36, 37, 38].
Refer to Section 2.2 for more information on the analysis of contact devices for these valves. The selection of contact devices for RCIC was based on the premise that RCIC operation is desired, thus any SILO which would lead to RCIC operation is beneficial and thus does not meet the criteria for selection.
Main Steam Isolation Valves HV-041-1F022A/B/C/D, HV-041-1F028A/B/C/O, HV-041-2F022A/B/C/D, HV-041-2F028A/B/C/D Electrical control for the solenoid-operated pilot valves is via relays B21H-Kl8A/B/C/D. These relays are slaves to B21H-Kl4A/B/C/D isolation logic relays [39, 40, 41, 42]. These relays are energized for at-power operation and de-energized to close the valves [43, 44, 45, 46]. In the energized state B21H-K14A/B/C/D are sealed in and any chatter in the control logic would break the seal-in and close the valves. This action is a desired response to the seismic event and for this reason chatter is acceptable and no contact devices in this circuit meet the selection criteria.
Only contact devices which could render the RCIC system inoperable were considered.
Page 8of110
The largest vulnerability to RCIC operation following a seismic event is contact chatter leading to a false RCIC Isolation Signal or false Turbine Trip. A false steam line break trip has the potential to delay RCIC operation while confirmatory inspections are being made. Chatter in the contacts of RCIC Isolation Signal Relay E51A-K31A or Steam Line High Differential Pressure Time Delay Relay E51A-K15A; or coincident chatter in the Turbine Exhaust Diaphragm High Pressure Relays E51A-K11A and E51A-K12A, or Reactor Pressure Relays E51A-K16A and E51A-K17A; may lead to a RCIC Isolation Signal and seal-in of E51A-K31A
 
[19). This would cause the RCIC Isolation Valves to close and the RCIC Trip and Throttle Valve to trip. Similar chatter in the contact devices that drive those relays could also lead to seal-in: PIS-050-1N655A, PIS-050-1N655E, PIS-049-1N658A, and PIS-049-1N658E (20]. (The three-second time delay associated with E51A-K15A will mask any chatter on PDIS-049-1N657A and PDS-049-1N660A, so they are excluded.)
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Main Steam Line Equalizer Valves HV-C-041-1F020, HV-C-041-2F020 These normally-open motor-operated valves are controlled by hand switches only [47, 48, 49].
The same rationale applies to the identical Division 3 devices: ES1A-K31C, E51A-K1SC, ESlA-KllC, K12C, E51A-K16C, ES1A-K17C, PIS-050-1N65SC, PIS-050-1N6SSG, PIS-049-1N658C, and PIS-049-1N658G (21, 22). Any chatter that may lead to the energization of the Trip and Throttle Valve Remote Trip Circuit is considered as SILO as it will close the valve and require a manual reset prior to restoration of the RCIC system. Chatter in Turbine Trip Auxiliary Relay E51A-K28, or in the devices which control this relay; the Turbine Exhaust High Pressure Relays E51A-K13 and E51A-K14, the Pump Suction Low Pressure Relay ESlA-KlO, and the Isolation Signal Relays E51A-K30A, and E51A-K67C (19). Similar chatter in the contact devices that drive those relays (and not already covered in the RCIC Isolation Signal analysis) could also lead to a turbine trip: ES1A-K30C, PIS-OS0-1N653, PIS-050-1N656A, and PIS-050-1N656E
Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch. Thus these valves are not affected by SILO.
[20, 21). Page 11 of 110 2.5 AC/DC POWER SUPPORT SYSTEMS 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 The AC and DC power support systems were reviewed for contact control devices in seal-in and lockout circuits that prevent the availability of DC and AC power sources. The following AC and DC power support systems were reviewed:
Main Steam Line Drain Valves HV-041-1F016, HV-041-1F019, HV-041-2F016, HV-041-2F019 The opening of normally-closed motor-operated valves HV-041-1F016/ HV-041-2F016 is commanded by a rugged hand switch with no seal-in contacts [SO, 51]. This valve opening control is insensitive to contact chatter and thus the valve will remain closed after the seismic event. As stated in Table B-2, HV-041-1F019/HV-041-2F019 do not need to be analyzed provided HV-041-1F016/HV-041-2F016 remain closed.
Reactor Water Clean-Up Valves Reactor Water Clean-Up Flow Control Valves HV-044-lFlOS, HV-044-2F105; Bottom Head Drain Flow Control Valves HV-044-lFlOO, HV-044-2F100 These normally-open motor-operated valves are controlled by hand switches only [52, 53]. Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch. Thus these valves are not affected by SILO.
Reactor Water Clean-Up Isolation Valves HV-044-lFOOl, HV-044-1F004, HV-044-2F001, HV-044-2F004; Bottom Head Drain Flow Control Valves These are normally-open motor-operated valves which close upon an isolation signal. Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch or isolation relay B21H-K24A/B [54, 55, 56, 57]. These relays are energized for at-power operation and de-energized to close the valves [58, 59, 60, 61]. In the energized state B21H-K24A/B are sealed in and any chatter in the control logic would break the seal-in and close the valves. This action is a desired response to the seismic event and for this reason chatter is acceptable and no contact devices in this circuit meet the selection criteria.
Reactor Core Isolation Cooling Valves Reactor Core Isolation Cooling Steam Supply Line Isolation Valves HV-049-lFOOl, HV-049-lFOOB, HV-049-2F007, HV-049-2FOOB These normally-open motor-operated valves are required to remain open to supply steam to the RCIC turbine. There is no seal-in in the opening circuit, and closure, if needed, is not blocked by SILO [62, 63, 64, 65]. Inadvertent closure of these valves is covered in the RCIC chatter analysis in Section 5.3.7 of Ref. [18].
Residual Heat Removal Valves Testable Check Valves HV-051-1F041A/B/C/D, HV-051-lFOSOA/B, HV-051-2F041A/8/C/D, HV-051-2F050A/B These solenoid-operated valves are controlled by a rugged, normally open push button [66, 67, 68, 69, 70, 71, 72, 73, 74, 75]. There are no SILO devices that would prevent the normal operation of these check valves.
Page 9 of 110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 RHR Injection Valves HV-051-1F017A/B/C/D, HV-051-2F017A/B/C/D; RHR Shutdown Cooling Injection Valves HV-051-1F015A/B, HV-051-2F015A/B Since the testable check valves are not chatter sensitive and can be credited to remain closed, these downstream motor operated valves do not need to be analyzed per the notes in Table B-2.
RHR Shutdown Cooling Isolation Valves HV-051-1F008, HV-051-2F008; RHR Shutdown Cooling Suction Valves HV-051-1F009, HV-051-2F009 These normally-closed motor-operated valves are opened via a normally-open control switch and relay permissive. The valves can be closed manually via the control switch and automatically via an isolation signal. Sympathetic chatter on B21H-K29A/B and 42/0 auxiliary contact could cause valve to open [76, 77, 78, 79], however the low reactor pressure permissive in control logic would prevent seal-in of B21H-K29A/B [58, 59, 60, 61]. After the period of strong shaking the normally-closed contact of B21H-K29A/B (isolation signal) would command these valves to reclose.
Because there is no seal-in and the valves reclose without operator intervention, chatter is acceptable and no contact devices in this circuit meet the selection criteria.
Core Spray Valves Testable Check Valves HV-052-1F006A/B, HV-052-2F006A/B These solenoid-operated valves are controlled by a rugged, normally open push button [80, 81, 82, 83]. There are no SILO devices that would prevent the normal operation of these check valves.
Core Spray Outboard Check Valves HV-052-108, HV-052-208; Core Spray Inboard Motor Operated Valve HV-052-1F005, HV-052-2F005 Since the testable check valves are not chatter sensitive and can be credited to remain closed, these downstream motor operated valves do not need to be analyzed per the notes in Table B-2.
High Pressure Core Injection Valves High Pressure Core Injection Steam Supply Line Isolation Valves HV-055-1F002, HV-055-1F003, HV-055-2F002, HV-055-2F003 These normally-open motor-operated valves supply steam to the HPCI turbine. The opening circuit is controlled by a rugged hand switch and permissive from E41A-K50B/D [84, 85, 86, 87] .
There is no seal-in in the opening circuit. The closing circuit is controlled manually by a rugged hand switch or automatically via the isolation relay E41A-K50B/D [88, 89]. Any chatter in the isolation logic would seal-in E41A-K50B/D and close the valves. Since RCIC, not HPCI, is credited for core cooling this seal-in causing valve closure is not a selection criterion . There is no SILO which would prevent closure of these valves and thus no contact devices in this circuit meet the selection criteria.
Page10of110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 2.3 REACTOR VESSEL PRESSURE CONTROL The reactor vessel pressure control function is identified as a key function in Reference [8) to be considered in the High Frequency Confirmation. The same report also states that "required post event pressure control is typically provided by passive devices" and that "no specific high frequency component chatter review is required for this function."
2.4 CORE COOLING The core cooling systems were reviewed for contact control devices in seal-in and lockout circuits that would prevent at least a single train of non-AC power driven decay heat removal from functioning. Limerick credits their steam turbine-driven Reactor Core Isolation Cooling (RCIC}
Pump to provide core decay-heat cooling.
The selection of contact devices for the Safety Relief Valves (SRVs) overlaps with the RCS/Reactor Vessel Inventory Control Category. Refer to Section 2.2 for more information on the analysis of contact devices for these valves.
The selection of contact devices for RCIC was based on the premise that RCIC operation is desired, thus any SILO which would lead to RCIC operation is beneficial and thus does not meet the criteria for selection. Only contact devices which could render the RCIC system inoperable were considered.
The largest vulnerability to RCIC operation following a seismic event is contact chatter leading to a false RCIC Isolation Signal or false Turbine Trip. A false steam line break trip has the potential to delay RCIC operation while confirmatory inspections are being made. Chatter in the contacts of RCIC Isolation Signal Relay E51A-K31A or Steam Line High Differential Pressure Time Delay Relay E51A-K15A; or coincident chatter in the Turbine Exhaust Diaphragm High Pressure Relays E51A-K11A and E51A-K12A, or Reactor Pressure Relays E51A-K16A and E51A-K17A; may lead to a RCIC Isolation Signal and seal-in of E51A-K31A [19). This would cause the RCIC Isolation Valves to close and the RCIC Trip and Throttle Valve to trip. Similar chatter in the contact devices that drive those relays could also lead to seal-in: PIS-050-1N655A, PIS-050-1N655E, PIS-049-1N658A, and PIS-049-1N658E (20]. (The three-second time delay associated with E51A-K15A will mask any chatter on PDIS-049-1N657A and PDS-049-1N660A, so they are excluded.) The same rationale applies to the identical Division 3 devices: ES1A-K31C, E51A-K1SC, ESlA-KllC, E51A-K12C, E51A-K16C, ES1A-K17C, PIS-050-1N65SC, PIS-050-1N6SSG, PIS-049-1N658C, and PIS-049-1N658G (21, 22).
Any chatter that may lead to the energization of the Trip and Throttle Valve Remote Trip Circuit is considered as SILO as it will close the valve and require a manual reset prior to restoration of the RCIC system. Chatter in Turbine Trip Auxiliary Relay E51A-K28, or in the devices which control this relay; the Turbine Exhaust High Pressure Relays E51A-K13 and E51A-K14, the Pump Suction Low Pressure Relay ESlA-KlO, and the Isolation Signal Relays E51A-K30A, and E51A-K67C (19).
Similar chatter in the contact devices that drive those relays (and not already covered in the RCIC Isolation Signal analysis) could also lead to a turbine trip: ES1A-K30C, PIS-OS0-1N653, PIS-050-1N656A, and PIS-050-1N656E [20, 21).
Page 11 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 2.5 AC/DC POWER SUPPORT SYSTEMS The AC and DC power support systems were reviewed for contact control devices in seal-in and lockout circuits that prevent the availability of DC and AC power sources. The following AC and DC power support systems were reviewed:
* Emergency Diesel Generators,
* Emergency Diesel Generators,
* Battery Chargers,
* Battery Chargers,
* Inverters,
* Inverters,
* EDG Ancillary Systems, and
* EDG Ancillary Systems, and
* Switchgear, Load Centers, and MCCs. Electrical power, especially DC, is necessary to support achieving and maintaining a stable plant condition following a seismic event. DC power relies on the availability of AC power to recharge the batteries.
* Switchgear, Load Centers, and MCCs.
The availability of AC power is dependent upon the Emergency Diesel Generators and their ancillary support systems. EPRI 3002004396
Electrical power, especially DC, is necessary to support achieving and maintaining a stable plant condition following a seismic event. DC power relies on the availability of AC power to recharge the batteries. The availability of AC power is dependent upon the Emergency Diesel Generators and their ancillary support systems. EPRI 3002004396 [8] requires confirmation that the supply of emergency power is not challenged by a SILO device. The tripping of lockout devices or circuit breakers is expected to require some level of diagnosis to determine if the trip was spurious due to contact chatter or in response to an actual system fault. The actions taken to diagnose the fault condition could substantially delay the restoration of emergency power.
[8] requires confirmation that the supply of emergency power is not challenged by a SILO device. The tripping of lockout devices or circuit breakers is expected to require some level of diagnosis to determine if the trip was spurious due to contact chatter or in response to an actual system fault. The actions taken to diagnose the fault condition could substantially delay the restoration of emergency power. In order to ensure contact chatter cannot compromise the emergency power system, control circuits were analyzed for the Emergency Diesel Generators (EDG), Battery Chargers, Vital AC Inverters, and Switchgear/Load Centers/MCCs as necessary to distribute power from the EDGs to the Battery Chargers and EDG Ancillary Systems. General information on the arrangement of safety-related AC and DC systems, as well as operation of the EDGs, was obtained from Limerick's UFSAR [90]. Limerick has eight (8) EDGs which provide emergency power for their two units. Each unit has four (4) divisions of Class lE loads with one EDG for each division [90, pp. 8.1-2]. The Class lE AC distribution scheme is shown on one-line drawings E-15 [91] (Unit 1) and E-16 [92] (Unit 2). The Class lE DC distribution scheme is described in the UFSAR (90, pp. 8.3-38] and shown on one-line drawings E-33 (93, 94] (Unit 1) and E-34 (95, 96] (Unit 2). The analysis necessary to identify contact devices in this category relies on conservative worsecase initial conditions and presumptions regarding event progression.
In order to ensure contact chatter cannot compromise the emergency power system, control circuits were analyzed for the Emergency Diesel Generators (EDG), Battery Chargers, Vital AC Inverters, and Switchgear/Load Centers/MCCs as necessary to distribute power from the EDGs to the Battery Chargers and EDG Ancillary Systems. General information on the arrangement of safety-related AC and DC systems, as well as operation of the EDGs, was obtained from Limerick's UFSAR [90]. Limerick has eight (8) EDGs which provide emergency power for their two units.
The analysis considers the reactor is operating at power with no equipment failures or LOCA prior to the seismic event. The Emergency Diesel Generators are not operating but are available.
Each unit has four (4) divisions of Class lE loads with one EDG for each division [90, pp. 8.1-2].
The seismic event is presumed to cause a Loss of Offsite Power (LOOP) and a normal reactor SCRAM. In response to bus undervoltage relaying detecting the LOOP, the Class lE control systems must automatically shed loads, start the EDGs, and sequentially load the diesel generators as designed.
The Class lE AC distribution scheme is shown on one-line drawings E-15 [91] (Unit 1) and E-16
Ancillary systems required for EDG operation as well as Class lE battery chargers and inverters must function as necessary.
[92] (Unit 2). The Class lE DC distribution scheme is described in the UFSAR (90, pp. 8.3-38] and shown on one-line drawings E-33 (93, 94] (Unit 1) and E-34 (95, 96] (Unit 2).
The goal of this analysis is to identify any vulnerable contact devices which could chatter during the seismic event, seal-in or lock-out, and prevent these systems from performing their intended safety-related function of supplying electrical power during the LOOP. The following sections contain a description of the analysis for each element of the AC/DC Support Systems. Contact devices are identified by description and Unit 1 Division 1 device ID in this narrative, however the analysis applies to the identical components and devices in all divisions of both units. The selected contact devices for both units and all divisions appear in Page 12 of 11 O 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 7-1 of Reference
The analysis necessary to identify contact devices in this category relies on conservative worse -
[18] where they are identified by device-specific ID, as indicated on the referenced control schematics. Emergency Diesel Generators The analysis of the Emergency Diesel Generators, 011, 012, 013, 014, 021, 022, 023, 024, is broken down into the generator protective relaying and diesel engine control. General descriptions of these systems and controls appear in the UFSAR [90, pp. 8.3-13]. Generator Protective Relaying The control circuits for the 152-11507 EOG circuit breaker [97, 98, 99, 100] include 186-115A, 186-115B, 186-115C bus lockout, 186-AG501 differential lockout, 151-AG501 phase overcurrent, and 132-AG501 anti-motoring protective relays. As mentioned above, there is no presumption of LOCA and thus none of these trips would be bypassed by the LOCA auxiliary control circuit. Chatter in any of these relays may prevent closure of the EOG circuit breaker. The generator differential lockout relay 186-AG501 may be tripped by chatter in the 187G-AG501 differential and 151N-AG501 ground fault protective relays [101]. In addition, chatter in the 187-115 safeguards bus differential protective relays, or the 151-11509, 151-11502 overcurrent and 151N-11509, 151N-11502 ground fault relays associated with primary and alternate power feeds, could lead to the tripping of the bus lockout relay. When tripped, this bus lockout relay prevents closure of the EDG, ESW pump, and load center transformer circuit breakers [102]. The exciter [103] and governor control circuitry
case initial conditions and presumptions regarding event progression. The analysis considers the reactor is operating at power with no equipment failures or LOCA prior to the seismic event. The Emergency Diesel Generators are not operating but are available. The seismic event is presumed to cause a Loss of Offsite Power (LOOP) and a normal reactor SCRAM.
[104, 105, 106, 107, 108, 109, 110, 111] was analyzed and no devices within these circuits would cause a sustained change in control state such that the diesel generator would not operate after the period of strong shaking ends. The drawing note associated with an auxiliary contact of exciter contactor Kl, "Trips Generator Circuit Breaker" [104, 105, 106, 107, 108, 109, 110, 111], is not accurate.
In response to bus undervoltage relaying detecting the LOOP, the Class lE control systems must automatically shed loads, start the EDGs, and sequentially load the diesel generators as designed.
The as-built condition of this auxiliary contact, connected to TBC terminals 6 and 10, was confirmed by walkdown to be not used. Refer to Attachment 9.4 of Reference
Ancillary systems required for EDG operation as well as Class lE battery chargers and inverters must function as necessary. The goal of this analysis is to identify any vulnerable contact devices which could chatter during the seismic event, seal-in or lock-out, and prevent these systems from performing their intended safety-related function of supplying electrical power during the LOOP.
[18] for more information regarding this walkdown.
The following sections contain a description of the analysis for each element of the AC/DC Support Systems. Contact devices are identified by description and Unit 1 Division 1 device ID in this narrative, however the analysis applies to the identical components and devices in all divisions of both units. The selected contact devices for both units and all divisions appear in Page 12 of 11 O
Diesel Engine Control Chatter analysis for the diesel engine control was performed on the start and shutdown circuits of each EDG [112, 113, 114] (Dll), [115, 116, 117] {012), [118, 119, 120] (Dl3), [121, 122, 123] {014), [124, 125, 126] (D21), [127, 128, 129] (022), [130, 131, 132] (023), [133, 134, 135] {D24). The start circuit is blocked by seal-in of the SDR engine trouble shutdown or SFR start failure relays. Chatter of the seal-in contacts of these relays or of the contacts of relays within the coil circuits of these relays may prevent EDG start. The SFR start failure relay is controlled by the two overcrank timing relays, T2A and T2B. Chatter in the contacts of either of these timing relays may energize the start failure relay and once energized it will seal in. The time delay function of these overcrank relays prevent momentary chatter in their coil circuits from energizing them. The SDR engine trouble shutdown relay is controlled by the EOS engine overspeed switch and EOR engine overspeed relay, the SE emergency stop relay, and a set of three switches and relays for each of the following engine faults: lube oil low pressure (OPLl, OPL2, OPL3, OPl, OP2, OP3), jacket coolant low pressure (CPLl, CPL2, CPL3, CPl, CP2, CP3), lube oil high temperature
 
{OTHl, OTH2, OTH3, OTl, OT2, OT3), and jacket coolant high temperature (CTHl, CTH2, CTH3, CTl, CT2, CT3). Chatter of the contacts of the overspeed relay is blocked by the overspeed switch contacts.
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 7-1 of Reference [18] where they are identified by device-specific ID, as indicated on the referenced control schematics.
Chatter of the overspeed switch could energize the overspeed relay and lead to seal-in of the Page 13of110 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 shutdown relay. Chatter in the contacts of the emergency stop relay could lead to seal-in ofthe shutdown relay. Chatter in the emergency stop relay coil circuit is blocked from energizing the emergency stop relay by non-vulnerable control switches.
Emergency Diesel Generators The analysis of the Emergency Diesel Generators, 011, 012, 013, 014, 021, 022, 023, 024, is broken down into the generator protective relaying and diesel engine control. General descriptions of these systems and controls appear in the UFSAR [90, pp. 8.3-13].
Coincident chatter (occurring in two out of three of each group) on the relays or switches of the lube oil and jacket coolant temperature faults could lead to seal-in of the shutdown relay. Coincident chatter in the lube oil and jacket coolant pressure relay contacts (OPl/2/3, CPl/2/3) may seal-in the shutdown relay. Since the pressure switches (OPLl/2/3, CPLl/2/3) are closed when the engine is not running, chatter in the T3A engine high speed time delay relay may cause the lube oil low pressure and jacket coolant low pressure relays to energize, which could lead to seal-in of the shutdown relay. This means that chatter in T3A could prevent engine start regardless of chatter in the pressure switches.
Generator Protective Relaying The control circuits for the 152-11507 EOG circuit breaker [97, 98, 99, 100] include 186-115A, 186-115B, 186-115C bus lockout, 186-AG501 differential lockout, 151-AG501 phase overcurrent, and 132-AG501 anti-motoring protective relays. As mentioned above, there is no presumption of LOCA and thus none of these trips would be bypassed by the LOCA auxiliary control circuit.
For this reason, this time delay relay will be selected and seismically analyzed while the pressure switches will not. If T3A is seismically screened (does not chatter), then chatter in the pressure switches are blocked. If T3A is not seismically screened (could potentially chatter), then the necessary mitigation actions for T3A would also address the potential for chatter in the pressure switches by default. All other contact devices involved in engine start and engine shutdown circuits were analyzed and, other than the devices noted above, none would cause a sustained change in control state such that the diesel generator would not start after the period of strong shaking ends. Battery Chargers Chatter analysis on the battery chargers was performed using information from the UFSAR [90] as well as vendor schematic diagrams [136, 137, 138]. Each battery charger has a high voltage shutdown circuit [90, pp. 8.3-43] which is intended to protect the batteries and DC loads from output overvoltage due to charger failure. The high voltage shutdown circuit has a latching output relay K which disconnects the auxiliary voltage transformer, shutting the charger down [136, 137]. Chatter in the contacts of this output relay will only have a temporary effect on the charger during the period of strong shaking. The operate coil of this relay is controlled by a vulnerable solid-state circuit [138]. No other vulnerable contact device affects the availability of the battery chargers.
Chatter in any of these relays may prevent closure of the EOG circuit breaker. The generator differential lockout relay 186-AG501 may be tripped by chatter in the 187G-AG501 differential and 151N-AG501 ground fault protective relays [101] . In addition, chatter in the 187-115 safeguards bus differential protective relays, or the 151-11509, 151-11502 overcurrent and 151N-11509, 151N-11502 ground fault relays associated with primary and alternate power feeds, could lead to the tripping of the bus lockout relay. When tripped, this bus lockout relay prevents closure of the EDG, ESW pump, and load center transformer circuit breakers [102].
Inverters Analysis of s c hematics for the lA, lB, 2A, and 2B RPS & UPS Static Inverters
The exciter [103] and governor control circuitry [104, 105, 106, 107, 108, 109, 110, 111] was analyzed and no devices within these circuits would cause a sustained change in control state such that the diesel generator would not operate after the period of strong shaking ends. The drawing note associated with an auxiliary contact of exciter contactor Kl, "Trips Generator Circuit Breaker" [104, 105, 106, 107, 108, 109, 110, 111], is not accurate. The as-built condition of this auxiliary contact, connected to TBC terminals 6 and 10, was confirmed by walkdown to be not used . Refer to Attachment 9.4 of Reference [18] for more information regarding this walkdown.
[139, 140], and the lA, lB, 2A, and 2B APRM UPS Inverters
Diesel Engine Control Chatter analysis for the diesel engine control was performed on the start and shutdown circuits of each EDG [112, 113, 114] (Dll), [115, 116, 117] {012), [118, 119, 120] (Dl3), [121, 122, 123]
[141, 142] revealed no vulnerable contact devices and thus chatter analysis is unnecessary.
{014), [124, 125, 126] (D21), [127, 128, 129] (022), [130, 131, 132] (023), [133, 134, 135] {D24).
EDG Ancillary Systems In order to start and operate the Emergency Diesel Generators, a number of components and systems are required.
The start circuit is blocked by seal-in of the SDR engine trouble shutdown or SFR start failure relays. Chatter of the seal-in contacts of these relays or of the contacts of relays within the coil circuits of these relays may prevent EDG start.
For the purpose of identifying electrical contact devices, only systems and components which are electrically controlled are analyzed.
The SFR start failure relay is controlled by the two overcrank timing relays, T2A and T2B. Chatter in the contacts of either of these timing relays may energize the start failure relay and once energized it will seal in. The time delay function of these overcrank relays prevent momentary chatter in their coil circuits from energizing them.
Information in the UFSAR [90] was used as appropriate for this analysis.
The SDR engine trouble shutdown relay is controlled by the EOS engine overspeed switch and EOR engine overspeed relay, the SE emergency stop relay, and a set of three switches and relays for each of the following engine faults: lube oil low pressure (OPLl, OPL2, OPL3, OPl, OP2, OP3),
Starting Air Based on Diesel Generator availability as an initial condition, the passive air reservoirs are presumed pressurized and the only active components in this system required to operate are the air start solenoids
jacket coolant low pressure (CPLl, CPL2, CPL3, CPl, CP2, CP3), lube oil high temperature {OTHl, OTH2, OTH3, OTl, OT2, OT3), and jacket coolant high temperature (CTHl, CTH2, CTH3, CTl, CT2, CT3) . Chatter of the contacts of the overspeed relay is blocked by the overspeed switch contacts.
[143, 144], which are covered under the EOG engine control analysis in Section above. Page 14 of 110 Combustion Air Intake and Exhaust 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 The combustion air intake and exhaust for the Diesel Generators are passive systems (145, 146] which do not rely on electrical control. Lube Oil The Diesel Generators utilize engine-driven mechanical lubrication oil pumps (147, 148] which do not rely on electrical control. Fuel Oil The Diesel Generator Fuel Oil System is described in the UFSAR (90, pp. 9.5-28]. The Diesel Generators utilize engine-driven mechanical pumps and DC-powered auxiliary pumps (149, 150] to supply fuel oil to the engines from the day tanks. The day tanks are re-supplied using powered Diesel Oil Transfer Pumps. Chatter analysis of the control circuits for the electricallypowered auxiliary and transfer pumps (151, 152, 153, 154, 155, 156, 157, 158] concluded they do not include SILO devices. The mechanical pumps do not rely on electrical control. Cooling Water The Diesel Generator Cooling Water System is described in the UFSAR (90, pp. 9.5-37]. This system consists of two cooling loops, jacket water and air cooler, which are each cooled by Emergency Service Water (ESW) (159, 160, 161, 162]. Engine driven pumps operating in both cooling loops are credited when the engine is operating.
Chatter of the overspeed switch could energize the overspeed relay and lead to seal-in of the Page 13of110
These mechanical pumps do not rely on electrical control. The electric jacket water pump is only used during shutdown periods and is thus not included in this analysis.
 
Four ESW pumps, DA, OB, DC, and OD, provide cooling water to the heat exchangers associated with the eight EDGs (163]. In automatic mode these pumps are started via the EDG Start Signal. Chatter analysis of the EDG start signal is included in Section above. A chatter analysis of the 152-11508 ESW pump circuit breaker control circuits (164, 165, 166] indicates the 186-115 bus lockout, 150/151-11508 phase overcurrent, and 150G-11508 ground fault relays all could prevent automatic (sequential) breaker closure following the seismic event. Ventilation The Diesel Generator Enclosure Ventilation System is described in the UFSAR (90, pp. 9.4-46]. Ventilation for each Diesel Generator Enclosure is provided via two exhaust fans (167, 168]. In automatic mode these fans are started via the EDG Start Signal. Chatter analysis of the EDG start signal is included in Section above. Other than SILO devices identified for the EDG start signal, chatter analysis of the control circuits for these fans (169, 170] and their associated dampers concluded they do not include SILO devices. Switchgear, Load Centers, and MCCs Power distribution from the EDGs to the necessary electrical loads (Battery Chargers, Inverters, Fuel Oil Pumps, and EDG Ventilation Fans) was traced to identify any SILO devices which could lead to a circuit breaker trip and interruption in power. This effort excluded the EDG circuit breakers, which are covered in Section above, and the ESW Pump breakers which are covered in Section above, as well as component-specific contactors and their control devices, which are covered in the analysis of each component above. Page 15 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 The medium-and low-voltage circuit breakers in 4160V Busses and 440V Load Centers which are supplying power to loads identified in this section have been identified for evaluation.
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 shutdown relay. Chatter in the contacts of the emergency stop relay could lead to seal-in ofthe shutdown relay. Chatter in the emergency stop relay coil circuit is blocked from energizing the emergency stop relay by non-vulnerable control switches. Coincident chatter (occurring in two out of three of each group) on the relays or switches of the lube oil and jacket coolant temperature faults could lead to seal-in of the shutdown relay. Coincident chatter in the lube oil and jacket coolant pressure relay contacts (OPl/2/3, CPl/2/3) may seal-in the shutdown relay.
For Unit 1 Division 1 these breakers are 152-11507 , 152-11505, 152-11508, 52-20133, and 52-20132. The 440V AC MCCs use Molded-Case Circuit Breakers (90, pp. 8.3-12] which are seismically rugged [8, pp. 2-11]; and DC power distribution is via non-vulnerable disconnect switches.
Since the pressure switches (OPLl/2/3, CPLl/2/3) are closed when the engine is not running, chatter in the T3A engine high speed time delay relay may cause the lube oil low pressure and jacket coolant low pressure relays to energize, which could lead to seal-in of the shutdown relay.
The only circuit breakers affected by protective relaying (not already covered) were those that distribute power via stepdown transformers from the 4KV Safeguards Busses to their associated 440V load centers. A chatter analysis of the control circuits for these circuit breakers [171, 172, 173] indicates the 186-115 bus lockout, 150/151-11505 transformer primary phase overcurrent, and 150G-11505 ground fault relays all could prevent automatic (sequential) breaker closure following the seismic event. 2.6  
This means that chatter in T3A could prevent engine start regardless of chatter in the pressure switches. For this reason, this time delay relay will be selected and seismically analyzed while the pressure switches will not. If T3A is seismically screened (does not chatter), then chatter in the pressure switches are blocked. If T3A is not seismically screened (could potentially chatter), then the necessary mitigation actions for T3A would also address the potential for chatter in the pressure switches by default.
All other contact devices involved in engine start and engine shutdown circuits were analyzed and, other than the devices noted above, none would cause a sustained change in control state such that the diesel generator would not start after the period of strong shaking ends.
Battery Chargers Chatter analysis on the battery chargers was performed using information from the UFSAR [90]
as well as vendor schematic diagrams [136, 137, 138]. Each battery charger has a high voltage shutdown circuit [90, pp. 8.3-43] which is intended to protect the batteries and DC loads from output overvoltage due to charger failure. The high voltage shutdown circuit has a latching output relay K which disconnects the auxiliary voltage transformer, shutting the charger down
[136, 137]. Chatter in the contacts of this output relay will only have a temporary effect on the charger during the period of strong shaking. The operate coil of this relay is controlled by a non-vulnerable solid-state circuit [138]. No other vulnerable contact device affects the availability of the battery chargers.
Inverters Analysis of schematics for the lA, lB, 2A, and 2B RPS & UPS Static Inverters [139, 140], and the lA, lB, 2A, and 2B APRM UPS Inverters [141, 142] revealed no vulnerable contact devices and thus chatter analysis is unnecessary.
EDG Ancillary Systems In order to start and operate the Emergency Diesel Generators, a number of components and systems are required. For the purpose of identifying electrical contact devices, only systems and components which are electrically controlled are analyzed. Information in the UFSAR [90] was used as appropriate for this analysis.
Starting Air Based on Diesel Generator availability as an initial condition, the passive air reservoirs are presumed pressurized and the only active components in this system required to operate are the air start solenoids [143, 144], which are covered under the EOG engine control analysis in Section above.
Page 14 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Combustion Air Intake and Exhaust The combustion air intake and exhaust for the Diesel Generators are passive systems (145, 146]
which do not rely on electrical control.
Lube Oil The Diesel Generators utilize engine-driven mechanical lubrication oil pumps (147, 148] which do not rely on electrical control.
Fuel Oil The Diesel Generator Fuel Oil System is described in the UFSAR (90, pp. 9.5-28]. The Diesel Generators utilize engine-driven mechanical pumps and DC-powered auxiliary pumps (149, 150]
to supply fuel oil to the engines from the day tanks. The day tanks are re-supplied using AC-powered Diesel Oil Transfer Pumps. Chatter analysis of the control circuits for the electrically-powered auxiliary and transfer pumps (151, 152, 153, 154, 155, 156, 157, 158] concluded they do not include SILO devices. The mechanical pumps do not rely on electrical control.
Cooling Water The Diesel Generator Cooling Water System is described in the UFSAR (90, pp. 9.5-37]. This system consists of two cooling loops, jacket water and air cooler, which are each cooled by Emergency Service Water (ESW) (159, 160, 161, 162]. Engine driven pumps operating in both cooling loops are credited when the engine is operating. These mechanical pumps do not rely on electrical control. The electric jacket water pump is only used during shutdown periods and is thus not included in this analysis.
Four ESW pumps, DA, OB, DC, and OD, provide cooling water to the heat exchangers associated with the eight EDGs (163]. In automatic mode these pumps are started via the EDG Start Signal.
Chatter analysis of the EDG start signal is included in Section above. A chatter analysis of the 152-11508 ESW pump circuit breaker control circuits (164, 165, 166] indicates the 186-115 bus lockout, 150/151-11508 phase overcurrent, and 150G-11508 ground fault relays all could prevent automatic (sequential) breaker closure following the seismic event.
Ventilation The Diesel Generator Enclosure Ventilation System is described in the UFSAR (90, pp. 9.4-46].
Ventilation for each Diesel Generator Enclosure is provided via two exhaust fans (167, 168]. In automatic mode these fans are started via the EDG Start Signal. Chatter analysis of the EDG start signal is included in Section above. Other than SILO devices identified for the EDG start signal, chatter analysis of the control circuits for these fans (169, 170] and their associated dampers concluded they do not include SILO devices.
Switchgear, Load Centers, and MCCs Power distribution from the EDGs to the necessary electrical loads (Battery Chargers, Inverters, Fuel Oil Pumps, and EDG Ventilation Fans) was traced to identify any SILO devices which could lead to a circuit breaker trip and interruption in power. This effort excluded the EDG circuit breakers, which are covered in Section above, and the ESW Pump breakers which are covered in Section above, as well as component-specific contactors and their control devices, which are covered in the analysis of each component above.
Page 15 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 The medium- and low-voltage circuit breakers in 4160V Busses and 440V Load Centers which are supplying power to loads identified in this section have been identified for evaluation. For Unit 1 Division 1 these breakers are 152-11507, 152-11505, 152-11508, 52-20133, and 52-20132 . The 440V AC MCCs use Molded-Case Circuit Breakers (90, pp. 8.3-12] which are seismically rugged [8, pp. 2-11]; and DC power distribution is via non-vulnerable disconnect switches.
The only circuit breakers affected by protective relaying (not already covered) were those that distribute power via stepdown transformers from the 4KV Safeguards Busses to their associated 440V load centers. A chatter analysis of the control circuits for these circuit breakers [171, 172, 173] indicates the 186-115 bus lockout, 150/151-11505 transformer primary phase overcurrent, and 150G-11505 ground fault relays all could prevent automatic (sequential) breaker closure following the seismic event.
2.6  


==SUMMARY==
==SUMMARY==
OF SELECTED COMPONENTS The investigation of high-frequency contact devices as described above was performed in Ref. [18]. A list of the contact devices requiring a high frequency confirmation is provided in Appendix B, Table B-1. The identified devices are evaluated in Ref. [17] per the methodology/description of Section 3 and 4. Results are presented in Section 5 and Table B-1. Page16of110 3 Seismic Evaluation
OF SELECTED COMPONENTS The investigation of high-frequency contact devices as described above was performed in Ref.
[18] . A list of the contact devices requiring a high frequency confirmation is provided in Appendix B, Table B-1. The identified devices are evaluated in Ref. [17] per the methodology/description of Section 3 and 4. Results are presented in Section 5 and Table B-1.
Page16of110


===3.1 HORIZONTAL===
15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 3  Seismic Evaluation 3.1 HORIZONTAL SEISMIC DEMAND Per Reference (8], Sect. 4.3, the basis for calculating high-frequency seismic demand on the subject components in the horizontal direction is the LIM horizontal ground motion response spectrum (GMRS), which was generated as part of the LIM Seismic Hazard and Screening Report
[4] submitted to the NRC on March 31, 2014, and accepted by the NRC on November 6, 2015 (14].
It is noted in Reference [8] that a Foundation Input Response Spectrum (FIRS) may be necessary to evaluate buildings whose foundations are supported at elevations different than the Control Point elevation. However, for sites founded on rock, per Ref. [8], "The Control Point GMRS developed for these rock sites are typically appropriate for all rock-founded structures and additional FIRS estimates are not deemed necessary for the high frequency confirmation effort."
The applicable buildings at LIM are founded on rock; therefore, the Control Point GMRS is representative of the input at the building foundation.
The horizontal GMRS values are provided in Table 3-2.
3.2 VERTICAL SEISMIC DEMAND As described in Section 3.2 of Reference. (8), the horizontal GMRS and site soil conditions are used to calculate the vertical GMRS (VGMRS), which is the basis for calculating high-frequency seismic demand on the subject components in the vertical direction.
The site's soil mean shear wave velocity vs. depth profile is provided in Reference. [4], Table 2.3.2-2 and reproduced below in Table 3-1.
Page 17 of 110


SEISMIC DEMAND 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Per Reference (8], Sect. 4.3, the basis for calculating high-frequency seismic demand on the subject components in the horizontal direction is the LIM horizontal ground motion response spectrum (GMRS), which was generated as part of the LIM Seismic Hazard and Screening Report [4] submitted to the NRC on March 31, 2014, and accepted by the NRC on November 6, 2015 (14]. It is noted in Reference
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 3-1: Soil Mean Shear Wave Velocity Vs. Depth Profile Depth     Depth   Thickness,     Vs1                               Vs30 Layer      (m)       (ft}     d1 (ft)   (ft/sec)     d1/Vs1   I [ d1 /Vsi]   (ft/s) 1      3.048     10.0       10.0       3,452     2.90E-03     2.90E-03 2      6.096     20.0       10.0       3,457     2.89E-03     5.79E-03 3      9.144     30.0       10.0       3,462     2.89E-03     8.68E-03 4      12.192     40.0       10.0       3,467     2.88E-03     1.16E-02 5      15.24     50.0       10.0       3,472     2.88E-03     1.44E-02 3,418 6      18.288     60.0       10.0       3,477     2.88E-03     1.73E-02 7      21.336     70.0       10.0       3,482     2.87E-03     2.02E-02 8      24.384     80.0       10.0       3,487     2.87E-03     2.31E-02 9      27.432     90.0       10.0       3,492     2.86E-03     2.59E-02 10      30.48     100.0     10.0       3,497     2.86E-03     2.88E-02 Using the shear wave velocity vs. depth profile, the velocity of a shear wave traveling from a depth of 30m (98.43ft) to the surface of the site (Vs30) is calculated per the methodology of Reference [8], Section 3.5.
[8] that a Foundation Input Response Spectrum (FIRS) may be necessary to evaluate buildings whose foundations are supported at elevations different than the Control Point elevation.
However, for sites founded on rock, per Ref. [8], "The Control Point GMRS developed for these rock sites are typically appropriate for all rock-founded structures and additional FIRS estimates are not deemed necessary for the high frequency confirmation effort." The applicable buildings at LIM are founded on rock; therefore, the Control Point GMRS is representative of the input at the building foundation.
The horizontal GMRS values are provided in Table 3-2. 3.2 VERTICAL SEISMIC DEMAND As described in Section 3.2 of Reference.
(8), the horizontal GMRS and site soil conditions are used to calculate the vertical GMRS (VGMRS), which is the basis for calculating high-frequency seismic demand on the subject components in the vertical direction.
The site's soil mean shear wave velocity vs. depth profile is provided in Reference.
[4], Table 2.3.2-2 and reproduced below in Table 3-1. Page 17 of 110 Layer 1 2 3 4 5 6 7 8 9 10 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 3-1: Soil Mean Shear Wave Velocity Vs. Depth Profile Depth Depth Thickness, Vs1 Vs30 (m) (ft} d1 (ft) (ft/sec) d1/Vs1 I [ d1 /Vsi] (ft/s) 3.048 10.0 10.0 3,452 2.90E-03 2.90E-03 6.096 20.0 10.0 3,457 2.89E-03 5.79E-03 9.144 30.0 10.0 3,462 2.89E-03 8.68E-03 12.192 40.0 10.0 3,467 2.88E-03 1.16E-02 15.24 50.0 10.0 3,472 2.88E-03 1.44E-02 18.288 60.0 10.0 3,477 2.88E-03 1.73E-02 3,418 21.336 70.0 10.0 3,482 2.87E-03 2.02E-02 24.384 80.0 10.0 3,487 2.87E-03 2.31E-02 27.432 90.0 10.0 3,492 2.86E-03 2.59E-02 30.48 100.0 10.0 3,497 2.86E-03 2.88E-02 Using the shear wave velocity vs. depth profile, the velocity of a shear wave traveling from a depth of 30m (98.43ft) to the surface of the site (Vs30) is calculated per the methodology of Reference
[8], Section 3.5.
* The time for a shear wave to travel through each soil layer is calculated by dividing the layer depth (d;) by the shear wave velocity of the layer (Vs;).
* The time for a shear wave to travel through each soil layer is calculated by dividing the layer depth (d;) by the shear wave velocity of the layer (Vs;).
* The total time for a wave to travel from a depth of 30m to the surface is calculated by adding the travel time through each layer from depths of Om to 30m (r[d;/Vs;)).
* The total time for a wave to travel from a depth of 30m to the surface is calculated by adding the travel time through each layer from depths of Om to 30m (r[d;/Vs;)).
* The velocity of a shear wave traveling from a depth of 30m to the surface is therefore the total distance {30m} divided by the total time; i.e., Vs30 = (3Dm}/r[d;/Vs;).
* The velocity of a shear wave traveling from a depth of 30m to the surface is therefore the total distance {30m} divided by the total time; i.e., Vs30 = (3Dm}/r[d;/Vs;).
* Note: The shear wave velocity is calculated based on time it takes for the shear wave to travel 30.48m {lOOft} instead of 30m (98.43ft).
* Note: The shear wave velocity is calculated based on time it takes for the shear wave to travel 30.48m {lOOft} instead of 30m (98.43ft). This small change in travel distance will have no impact on identifying soil class type.
This small change in travel distance will have no impact on identifying soil class type. The site's soil class is determined by using the site's shear wave velocity (Vs30) and the peak ground acceleration (PGA) of the GMRS and comparing them to the values within Reference
The site's soil class is determined by using the site's shear wave velocity (Vs30) and the peak ground acceleration (PGA) of the GMRS and comparing them to the values within Reference [8),
[8), Table 3-1. Based on the PGA of 0.193g and the shear wave velocity of 3418ft/s, the site soil class is B-Hard. Once a site soil class is determined, the mean vertical vs. horizontal GMRS ratios (V/H) at each frequency are determined by using the site soil class and its associated V/H values in Reference
Table 3-1. Based on the PGA of 0.193g and the shear wave velocity of 3418ft/s, the site soil class is B-Hard.
[8], Table 3-2. The vertical GMRS is then calculated by multiplying the mean V/H ratio at each frequency by the horizontal GMRS acceleration at the corresponding frequency.
Once a site soil class is determined, the mean vertical vs. horizontal GMRS ratios (V/H) at each frequency are determined by using the site soil class and its associated V/H values in Reference
It is noted that Reference
[8], Table 3-2.
[8], Table 3-2 values are constant between O.lHz and 15Hz. The V /H ratios and VG MRS values are provided in Table 3-2 of this report. Figure 3-1 below provides a plot of the horizontal GMRS, V/H ratios, and vertical GMRS for LIM. Page 18of110 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table 3-2: Horizontal and Vertical Ground Motions Response Spectra Frequency (Hz) HGMRS (g) V/H Ratio VGMRS (g) 100 0.193 0.8 0.154 90 0.195 0.82 0.160 80 0.198 0.87 0.172 70 0.202 0.91 0.184 60 0.210 0.92 0.193 so 0.228 0.9 0.205 45 0.243 0.89 0.216 40 0.258 0.86 0.222 35 0.279 0.81 0.226 30 0.306 0.75 0.230 25 0.339 0.7 0.237 20 0.363 0.68 0.247 15 0.381 0.68 0.259 12.5 0.386 0.68 0.262 10 0.385 0.68 0.262 9 0.381 0.68 0.259 8 0.374 0.68 0.254 7 0.361 0.68 0.245 6 0.340 0.68 0.231 5 0.315 0.68 0.214 4 0.264 0.68 0.180 3.5 0.235 0.68 0.160 3 0.203 0.68 0.138 2.5 0.169 0.68 0.115 2 0.149 0.68 0.101 1.5 0.125 0.68 0.085 1.25 0.106 0.68 0.072 1 0.090 0.68 0.06 1 0.9 0.082 0.68 0.056 0.8 0.073 0.68 0.049 0.7 0.065 0.68 0.044 0.6 0.056 0.68 0.038 0.5 0.046 0.68 0.031 0.4 0.036 0.68 0.025 0.35 0.032 0.68 0.022 0.3 0.027 0.68 0.019 0.25 0.023 0.68 0.016 0.2 0.018 0.68 0.012 0.15 0.014 0.68 0.009 0.125 0.011 0.68 0.008 0.1 0.009 0.68 0.006 Page19of110 0.50 0.40 :!9 0.30 c 0 ':t:i t! CV Qj ti 0.20 ct -VG MRS -HGMRS --V/H Ratio (B-Hard) h-L I_ I I !-="==-----_._ -'-----I 0.10 ------0.00 0.1 1 Frequency
The vertical GMRS is then calculated by multiplying the mean V/H ratio at each frequency by the horizontal GMRS acceleration at the corresponding frequency. It is noted that Reference [8],
[Hz] 10 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 1.00 ,, _,,__, .,. 0.90 , \ ,' \ I \ I \ -, 0.80 0 ".jj RI ex: , ___ ., 100 :c 0.70 > 0.60 0.50 Figure 3-1 Plot of the Horizontal and Vertical Ground Motions Response Spectra and V /H Ratios Page 20 of 110 
Table 3-2 values are constant between O.lHz and 15Hz.
The V/H ratios and VG MRS values are provided in Table 3-2 of this report.
Figure 3-1 below provides a plot of the horizontal GMRS, V/H ratios, and vertical GMRS for LIM.
Page 18of110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table 3-2: Horizontal and Vertical Ground Motions Response Spectra Frequency (Hz)   HGMRS (g)     V/H Ratio VGMRS (g) 100           0.193         0.8       0.154 90           0.195         0.82       0.160 80           0.198         0.87       0.172 70           0.202         0.91       0.184 60           0.210         0.92       0.193 so           0.228         0.9       0.205 45           0.243         0.89       0.216 40           0.258         0.86       0.222 35           0.279         0.81       0.226 30           0.306         0.75       0.230 25           0.339         0.7       0.237 20           0.363         0.68       0.247 15           0.381         0.68       0.259 12.5         0.386         0.68       0 .262 10           0.385         0.68       0 .262 9           0.381         0.68       0 .259 8           0.374         0.68       0.254 7           0.361         0.68       0.245 6           0.340         0.68       0.231 5           0.315         0.68       0.214 4           0.264         0.68       0.180 3.5         0.235         0 .68     0 .160 3           0.203         0.68       0 .138 2.5         0.169         0.68       0.115 2           0.149         0.68       0.101 1.5         0.125         0.68       0.085 1.25           0.106       0.68       0.072 1           0.090         0.68       0.061 0 .9         0 .082       0 .68     0 .056 0.8           0.073       0.68       0.049 0 .7         0.065       0.68       0.044 0.6           0.056       0.68       0.038 0.5           0.046       0.68       0.031 0.4           0.036         0.68     0.025 0 .35         0.032       0 .68     0.022 0.3           0.027         0.68     0.019 0.25           0.023         0.68     0.016 0.2           0.018         0 .68     0.012 0.15           0.014         0.68     0.009 0 .125         0.011         0.68     0.008 0.1           0.009         0.68     0.006 Page19of110


===3.3 COMPONENT===
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 0.50                                                              ---~-.-                    1.00
                -  VG MRS
                -  HGMRS                                                            ,,
0.40      - - V/H Ratio (B-Hard) h -
                                                                                        \
                                                                                                .,. 0 .90
                                                                              ,'          \
:!9 c
0
':t:i 0.30  L                                                    --~1' I
I              \
                                                                                            \
                                                                                              ~'-,  0 .80 0
                                                                                                          ".jj RI ex:
t!                                                                                                        :c CV Qj ti  0.20 I_      I              I                            ___ .,,                            0 .70
                                                                                                          ~
ct          !-="==-----_._-'- ----
I 0 .10 - -        ----                                                                        0 .60 0.00                                                                                          0 .50 0.1                        1                      10                              100 Frequency [Hz]
Figure 3-1 Plot of the Horizontal and Vertical Ground Motions Response Spectra and V/H Ratios Page 20 of 110


HORIZONTAL SEISMIC DEMAND 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Per Reference
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 3.3 COMPONENT HORIZONTAL SEISMIC DEMAND Per Reference [8] the peak horizontal acceleration is amplified using the following two factors to determine the horizontal in-cabinet response spectrum:
[8] the peak horizontal acceleration is amplified using the following two factors to determine the horizontal in-cabinet response spectrum:
* Horizontal in-structure amplification factor AFsH to account for seismic amplification at floor elevations above the host building's foundation
* Horizontal in-structure amplification factor AFsH to account for seismic amplification at floor elevations above the host building's foundation
* Horizontal in-cabinet amplification factor AFc to account for seismic amplification within the host equipment (cabinet, switchgear, motor control center, etc.) The in-structure amplification factor AFsH is derived from Figure 4-3 in Reference
* Horizontal in-cabinet amplification factor AFc to account for seismic amplification within the host equipment (cabinet, switchgear, motor control center, etc.)
[8]. The cabinet horizontal amplification factor, AFc is associated with a given type of cabinet construction.
The in-structure amplification factor AFsH is derived from Figure 4-3 in Reference [8]. The in-cabinet horizontal amplification factor, AFc is associated with a given type of cabinet construction. The three general cabinet types are identified in Reference [8] and Appendix I of EPRI NP-7148-SL [13] assuming 5% in-cabinet response spectrum damping. EPRI NP-7148-SL [13]
The three general cabinet types are identified in Reference
classified the cabinet types as high amplification structures such as switchgear panels and other similar large flexible panels, medium amplification structures such as control panels and control room bench board panels and low amplification structures such as motor control centers.
[8] and Appendix I of EPRI NP-7148-SL
All of the electrical cabinets containing the components subject to high frequency confirmation (see Table B-1 in Appendix B) can be categorized into one of the in-cabinet amplification categories in Reference [8] as follows:
[13] assuming 5% in-cabinet response spectrum damping. EPRI NP-7148-SL
* Motor Control Centers are typical motor control center cabinets consisting of a lineup of several interconnected sections. Each section is a relatively narrow cabinet structure with height-to-depth ratios of about 4.5 that allow the cabinet framing to be efficiently used in flexure for the dynamic response loading, primarily in the front-to-back direction. This results in higher frame stresses and hence more damping which lowers the cabinet response. In addition, the subject components are not located on large unstiffened panels that could exhibit high local amplifications. These cabinets qualify as low amplification cabinets.
[13] classified the cabinet types as high amplification structures such as switchgear panels and other similar large flexible panels, medium amplification structures such as control panels and control room bench board panels and low amplification structures such as motor control centers. All of the electrical cabinets containing the components subject to high frequency confirmation (see Table B-1 in Appendix B) can be categorized into one of the in-cabinet amplification categories in Reference
* Switchgear cabinets are large cabinets consisting of a lineup of several interconnected sections typical of the high amplification cabinet category. Each section is a wide box-type structure with height-to-depth ratios of about 1.5 and may include wide stiffened panels. This results in lower stresses and hence less damping which increases the enclosure response . Components can be mounted on the wide panels, which results in the higher in-cabinet amplification factors.
[8] as follows:
* Control cabinets are in a lineup of several interconnected sections with moderate width.
* Motor Control Centers are typical motor control center cabinets consisting of a lineup of several interconnected sections.
Each section consists of structures with height-to-depth ratios of about 3 which results in moderate frame stresses and damping. The response levels are mid-range between MCCs and switchgear and therefore these cabinets can be considered in the medium amplification category.
Each section is a relatively narrow cabinet structure with height-to-depth ratios of about 4.5 that allow the cabinet framing to be efficiently used in flexure for the dynamic response loading, primarily in the front-to-back direction.
3.4 COMPONENT VERTICAL SEISMIC DEMAND The component vertical demand is determined using the peak acceleration of the VG MRS between 15 Hz and 40 Hz and amplifying it using the following two factors:
This results in higher frame stresses and hence more damping which lowers the cabinet response.
* Vertical in-structure amplification factor AFsv to account for seismic amplification at floor elevations above the host building's foundation Page 21of110
In addition, the subject components are not located on large unstiffened panels that could exhibit high local amplifications.
 
These cabinets qualify as low amplification cabinets.
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177
* Switchgear cabinets are large cabinets consisting of a lineup of several interconnected sections typical of the high amplification cabinet category.
* Verti cal in-cabinet amplification factor AFc to account for seismic amplification within the host equipment (cabinet, switchgear, motor control center, etc.)
Each section is a wide type structure with height-to-depth ratios of about 1.5 and may include wide stiffened panels. This results in lower stresses and hence less damping which increases the enclosure response. Components can be mounted on the wide panels, which results in the higher in-cabinet amplification factors.
The in-structure amplification factor AFsv is derived from Figure 4-4 in Reference [8]. The in-cabinet vertical amplification factor, AFc is derived in Reference [8] and is 4.7 for all cabinet types.
* Control cabinets are in a lineup of several interconnected sections with moderate width. Each section consists of structures with height-to-depth ratios of about 3 which results in moderate frame stresses and damping. The response levels are mid-range between MCCs and switchgear and therefore these cabinets can be considered in the medium amplification category.  
Page 22of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 4 Contact Device Evaluations Per Reference [8], seismic capacities (the highest seismic test level reached by the contact device without chatter or other malfunction) for each subject contact device are determined by the following procedures:
(1) If a contact device was tested as part of the EPRI High Frequency Testing program [7],
then the component seismic capacity from this program is used.
(2) If a contact device was not tested as part of [7], then one or more of the following means to determine the component capacity were used:
(a) Device-specific seismic test reports (either from the station or from the SQURTS testing program.
(b) Generic Equipment Ruggedness Spectra (GERS) capacities per [9], [10], [11], and [12].
(c) Assembly (e.g. electrical cabinet) tests where the component functional performance was monitored.
The high-frequency capacity of each device was evaluated with the component mounting point demand from Section 3 using the criteria in Section 4.5 of Reference [8]
A summary of the high-frequency evaluation conclusions is provided in Table B-1 in Appendix B of this report.
Page 23 of 11 o
 
15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 5  Conclusions 5.1 GENERAL CONCLUSIONS LIM has performed a High Frequency Confirmation evaluation in response to the NRC's 50.54(f) letter [1] using the methods in EPRI report 3002004396 [8].
The evaluation identified a total of 528 components that required evaluation. As summarized in Table B-1 in Appendix B, all of the devices have adequate seismic capacity for the reevaluated seismic hazard [4] .
5.2 IDENTIFICATION OF FOLLOW-UP ACTIONS No follow-up actions were identified.
Page 24of110
 
15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 6 References 1  NRC (E. Leeds and M . Johnson) Letter to All Power Reactor Licensees et al., "Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f} Regarding Recommendations 2.1, 2.3 and 9.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident," March 12, 2012, ADAMS Accession Number ML12053A340 2  NRC (W. Dean) Letter to the Power Reactor Licensees on the Enclosed List. "Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54{f} Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident." October 27, 2015, ADAMS Accession Number ML15194A015 3  NRC (J. Davis) Letter to Nuclear Energy Institute (A. Mauer). "Endorsement of Electric Power Research Institute Final Draft Report 3002004396, 'High Frequency Program :
Application Guidance for Functional Confirmation and Fragility."' September 17, 2015, ADAMS Accession Number ML15218A569 4  Seismic Hazard and Screening Report in Response to the 50.54{f) Information Request Regarding Fukushima Near-Term Task Force Recommendation 2.1: Seismic for Limerick Generating Station, Unit 1 and 2 dated March 31, 2014, ADAMS Accession Number ML14090A236 5  Not Used 6  EPRI 1025287, "Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details (SPID} for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1:
Seismic." February 2013 7  EPRI 3002002997, "High Frequency Program: High Frequency Testing Summary."
September 2014 8  EPRI 3002004396, "High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation ." July 2015 9  EPRI NP-7147-SL, "Seismic Ruggedness of Relays." August 1991 10  EPRI NP-7147-SLV2, Addendum 1, "Seismic Ruggedness of Relays", September 1993 11  EPRI NP-7147-SLV2, Addendum 2, "Seismic Ruggedness of Relays", April 1995 12  EPRI NP-7147 SQUG Advisory 2004-02, "Relay GERS Corrections." September 10, 2004 13  EPRI NP-7148-SL, "Procedure for Evaluating Nuclear Power Plant Relay Seismic Functionality", 1990 14  NRC {F. Vega) Letter to Limerick Generating Station (B. Hanson), "Limerick Generating Station, Unit 1 and 2 - Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54{f), Seismic Hazard Reevaluations for Recommendation 2.1 ofthe Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident (TAC NOS. MF3864 and MF3865)." November 6, 2015, ADAMS Accession Number ML15296A492 15  Recommendations For Enhancing Reactor Safety in the 21' 1 Century, "The Near-Term Task Force Review of Insights from the Fukushima Dai-I chi Accident" July 12, 2011, ADAMS Accession Number ML111861807 16  NEI 12-06, Rev. 2, "Diverse and Flexible Coping Strategies {FLEX) Implementation Guide" Page 25 of 11 O
 
1SC434S-RPT-002, Rev. 0 Correspondence No.: RS-16-177 17 1SC434S-CAL-001, Rev. 2, "High Frequency Functional Confirmation and Fragility Evaluation of Relays" 18 1SC434S-RPT-001, Rev. 3, "Selection of Relays and Switches for High Frequency Seismic Evaluation" 19 Limerick Drawing ESl-1040-E-003 Rev. 32, Elementary Diagram Reactor Core Isolation 20 Limerick Drawing ESl-1040-E-013 Rev. 16, Elementary Diagram RCIC System Sheet 3A 21 Limerick Drawing ESl-1040-E-004 Rev. 30, Elementary Diagram Reactor Core Isolation 22 Limerick Drawing ESl-1040-E-014 Rev. 16, Elementary Diagram RCIC System Sheet 4A 23 Limerick Drawing M-0041Sheet1Rev.47, Piping and Instrument Diagram Nuclear Boiler 24 Limerick Drawing M-0041 Sheet 3 Rev. SS, Piping and Instrument Diagram Nuclear Boiler 2S Limerick Drawing M-0041Sheet4 Rev. 43, Piping and Instrument Diagram Nuclear Boiler 26 Limerick Drawing M-0041 Sheet 6 Rev. SS, Piping and Instrument Diagram Nuclear Boiler 27 Limerick Drawing B21-1060-E-004 Rev. 14, Elementary Diagram Automatic De pressurization System Sheet 4 28 Limerick Drawing B21-1060-E-OOS Rev. 13, Elementary Diagram Automatic Depressurization System Sheet S 29 Limerick Drawing B21-1060-E-018 Rev. 7, Elementary Diagram Automatic Depressurization System 30 Limerick Drawing B21-1060-E-019 Rev. 6, Elementary Diagram Automatic Depressurization System 31 Limerick Drawing B21-1060-E-003 Rev. 16, Elementary Diagram Automatic Depressurization System 32 Limerick Drawing B21-1060-E-01S Rev. S, Elementary Diagram Auto Depressurization System 33 Limerick Drawing B21-1060-E-008 Rev. 14, Elementary Diagram Auto Depressurization System Sheet 3A 34 Limerick Drawing B21-1060-E-016 Rev. 4, Elementary Diagram Auto Depressurization System Sheet 3A 3S Limerick Drawing B21-1060-E-006 Rev. 19, Elementary Diagram Auto Depressurization System Sheet 6 36 Limerick Drawing B21-1060-E-011Rev.12, Elementary Diagram Auto Depressurization System Sheet 6A 37 Limerick Drawing B21-1060-E-020 Rev. 7, Elementary Diagram Auto Depressurization System 38 Limerick Drawing B21-1060-E-021 Rev. 6, Elementary Diagram Auto Depressurization System 39 Limerick Drawing B21-1090-E-010 Rev. 23, Elementary Diagram Nuclear Steam Supply Shutoff System 40 Limerick Drawing B21-1090-E-011 Rev. 23, Elementary Diagram Nuclear Steam Supply Shutoff System 41 Limerick Drawing B21-1090-E-027 Sheet 10 Rev. 8, Elementary Diagram Reactor Core Isolation 42 Limerick Drawing B21-1090-E-027 Sheet 11 Rev. 9, Elementary Diagram Nuclear Steam Supply Shutoff System Page 26 of 11 O
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 43 Limerick Drawing B21-1090-E-006 Rev. 27, Elementary Diagram Nuclear Steam Supply Shutoff System Sheet 6 44 Limerick Drawing B21-1090-E-007 Rev. 25, Elementary Diagram Nuclear Steam Supply Shutoff System Sheet 7 45 Limerick Drawing B21-1090-E-027 Sheet 6 Rev. 7, Elementary Diagram Nuclear Steam Supply Shutoff System 46 Limerick Drawing B21-1090-E-027 Sheet 7 Rev. 8, Elementary Diagram Nuclear Steam Supply Shutoff System 47 Limerick Drawing B21-1040-E-004 Rev. 23, Elementary Diagram Nuclear Boiler Process 48 Limerick Drawing B21-1040-E-008 Rev. 8, Elementary Diagram Nuclear Boiler Process 49 Limerick Drawing B21-1040-E-009 Rev. 9, Elementary Diagram Nuclear Boiler Process 50 Limerick Drawing B21-1090-E-032 Sheet 1 Rev. l, HV-041-1F016 Main Steam Drain Inboard PCIV Steam Drains Inboard 51 Limerick Drawing B21-1090-E-038 Sheet 1 Rev. 0, Elementary Diagram HV-051-2F016 52 Limerick Drawing G31-1040-E-001 Rev. 46, Elementary Diagram Reactor Water Cleanup System 53 Limerick Drawing G31-1040-E-005 Rev. 24, Elementary Diagram Reactor Water Cleanup System 54 Limerick Drawing B21-1090-E-012 Rev. 29, Elementary Diagram Nuclear Steam Supply Shutoff System 55 Limerick Drawing B21-1090-E-016 Sheet 2 Rev. 4, Elementary Diagram Nuclear Steam Supply Shutoff System 56 Limerick Drawing B21-1090-E-027 Sheet 12 Rev. 16, Elementary Diagram Nuclear Steam Supply Shutoff System 57 Limerick Drawing B21-1090-E-027 Sheet 2A Rev. 15, Elementary Diagram Nuclear Steam Supply Shutoff System 58 Limerick Drawing B21-1090-E-008 Rev. 32, Elementary Diagram Nuclear Steam Supply Sheet 8 59 Limerick Drawing B21-1090-E-017 Rev. 33, Elementary Diagram Nuclear Steam Supply Sheet 8A 60 Limerick Drawing B21-1090-E-027 Sheet 8 Rev. 16, Elementary Diagram Nuclear Steam Supply Shutoff System 61 Limerick Drawing B21-1090-E-027 Sheet 8A Rev. 14, Elementary Diagram Nuclear Steam Supply Shutoff System 62 Limerick Drawing ESl-1040-E-052 Sheet 1 Rev . l, Schematic HV-049-1F007 Main Steam Supply Inboard PCIV Inboard 63 Limerick Drawing ESl-1040-E-053 Sheet 1 Rev. 2, Schematic HV-049-1F008 RCIC Steam Line Outboard PCIV Outboard 64 Limerick Drawing ESl-1040-E-056 Sheet 1Rev.1, Elementary Diagram HV-049-2F007 65 Limerick Drawing ESl-1040-E-057 Sheet 1 Rev. 1, Elementary Diagram HV-049-2F008 66 Limerick Drawing Ell-1040-E-016 Rev. 35, Elementary Diagram Residual Heat Removal System 67 Limerick Drawing Ell-1040-E-018 Rev. 35, Elementary Diagram Residual Heat Removal System Page 27 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 68 Limerick Drawing Ell-1040-E-019 Rev. 32, Elementary Diagram Residual Heat Removal System 69 Limerick Drawing Ell-1040-E-020 Rev. 23, Elementary Diagram Residual Heat Removal System 70 Limerick Drawing Ell-1040-E-021 Rev. 21,  Elementary Diagram Residual Heat Removal System 71 Limerick Drawing Ell-1040-E-049 Rev. 17,  Elementary Diagram Residual Heat Removal System 72 Limerick Drawing Ell-1040-E-051Rev.16,    Elementary Diagram Residual Heat Removal System 73 Limerick Drawing Ell-1040-E-052 Rev. 15,  Elementary Diagram Residual Heat Removal System 74 Limerick Drawing Ell-1040-E-053 Rev. 10, Elementary Diagram Residual Heat Removal System 75 Limerick Drawing Ell-1040-E-054 Rev. 11, Elementary Diagram Residual Heat Removal System 76 Limerick Drawing B21-1090-E-018 Sheet 2 Rev. 4, Elementary Diagram Nuclear Steam Supply Shutoff System 77 Limerick Drawing B21-1090-E-033 Sheet 1Rev.1, Schematic HV-051-1F009 RHR Shutdown Cooling Suction Inboard PCI Inboard 78 Limerick Drawing B21-1090-E-034 Sheet 1 Rev. 1, Elementary Diagram HV-051-2F008 79 Limerick Drawing  B21-1090-E-035 Rev. 1, Elementary Diagram HV-051-2F009 80 Limerick Drawing  E21-1040-E-009 Rev. 25, Elementary Diagram Core Spray System 81 Limerick Drawing  E21-1040-E-010 Rev. 22, Elementary Diagram Core Spray System 82 Limerick Drawing  E21-1040-E-030 Rev. 9, Elementary Diagram Core Spray System 83 Limerick Drawing E21-1040-E-031 Rev. 8, Elementary Diagram Core Spray System 84 Limerick Drawing E41-1040-E-014 Sheet 2 Rev. 1, Elementary Diagram HPCI System 85 Limerick Drawing E41-1040-E-013 Sheet 2 Rev. 0, Elementary Diagram HPCI System 86 Limerick Drawing E41-1040-E-027 Sheet 2 Rev. 0, Elementary Diagram HPCI System Sheet 11 87 Limerick Drawing E41-1040-E-027 Sheet 6 Rev. 0, Elementary Diagram HPCI System 88 Limerick Drawing E41-1040-E-006 Rev. 36, Elementary Diagram HPCI System 89 Limerick Drawing E41-1040-E-022 Rev. 8, Elementary Diagram HPCI System 90 Limerick Report, "Updated Final Safety Analysis Report (UFSAR)," Rev. 18, September 2016 91 Limerick Drawing E-0015 Sheet 1 Rev. 30, Single Line Meter and Relay Diagram 4KV Safeguard Power System Unit 1 92 Limerick Drawing E-0016 Sheet 1 Rev. 26, Single Line Meter and Relay Diagram 4KV Safeguard Power System Unit 2 93 Limerick Drawing E-0033 Sheet 1 Rev. 45, Single Line Meter and Relay Diagram 125, 250VDC System 94 Limerick Drawing E-0033 Sheet 2 Rev. 47, Single Line Meter and Relay Diagram 125, 250VDC System 95 Limerick Drawing E-0034 Sheet 1 Rev. 38, Single Line Meter and Relay Diagram 125, 250V DC System Page 28 of 11 O
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 96  Limerick Drawing E-0034 Sheet 2 Rev. 40, Single Line Diagram Instrumentation AC System 97  Limerick Drawing E-0164 Sheet 1 Rev. 19, Safeguard Busses Dll thru D14, D21 thru D24 Generator Breakers 4KV 98  Limerick Drawing E-0164 Sheet 3 Rev. 10, Safeguard Busses Dll thru D14 and D21 thru D24 Generator Breakers 4KV 99  Limerick Drawing E-0164 Sheet 5 Rev. 9, Safeguard Busses Dll thru D14 Generator Breakers 4KV 100 Limerick Drawing E-0164 Sheet SA Rev. 1, Schematic Diagram Safeguard Busses D21, 22, 23, 24 Generator Breakers 4KV Unit 2 101 Limerick Drawing E-0169 Sheet 1 Rev. 11, Schematic Diagram - Diesel Generator Protective 102 Limerick Drawing E-0168 Sheet 1 Rev. 6, Schematic Diagram - Safeguard Buses, Protective Relaying 103 Limerick Drawing M-071-00147 Sheet 1 Rev. 21, Schematic Power Chassis Nuclear Exciter/Regulator 104 Limerick Drawing M-071-00065 Sheet lA Rev. 19, Control Schematic Dll Diesel Generator 105 Limerick Drawing M-071-00065 Sheet 6 Rev. 2, Control Schematic D12 Diesel Generator 106 Limerick Drawing M-071-00065 Sheet 12 Rev. 3, Control Schematic D13 Diesel Generator 107 Limerick Drawing M-071-00065 Sheet 18 Rev. 3, Control Schematic D14 Diesel Generator 108 Limerick Drawing M-071-00065 Sheet 24 Rev. 3, Control Schematic D21 Diesel Generator 109 Limerick Drawing M-071-00065 Sheet 30 Rev. 3, Control Schematic D22 Diesel Generator 110 Limerick Drawing M-071-00065 Sheet 36 Rev. 2, Control Schematic D23 Diesel Generator 111 Limerick Drawing M-071-00065 Sheet 42 Rev. 3, Control Schematic D24 Diesel Generator 112 Limerick Drawing M-071-00048 Sheet 1 Rev. 30, Schematic Engine Control Dll Diesel Generator 113 Limerick Drawing M-071-00048 Sheet 2 Rev. 32, Schematic Engine Control Dll Diesel Generator 114 Limerick Drawing M-071-00048 Sheet 3 Rev. 33, Schematic Engine Control Dll Diesel Generator 115 Limerick Drawing M-071-00048 Sheet 6 Rev. 14, Schematic Engine Control D12 Diesel Generator 116 Limerick Drawing M-071-00048 Sheet 7 Rev. 3, Schematic Engine Control D12 Diesel Generator 117 Limerick Drawing M-071-00048 Sheet 8 Rev. 1, Schematic Engine Control D12 Diesel Generator 118 Limerick Drawing M-071-00048 Sheet 11Rev.0, Schematic Engine Control D13 Diesel Generator 119 Limerick Drawing M-071-00048 Sheet 12 Rev. 3, Schematic Engine Control D13 Diesel Generator 120 Limerick Drawing M-071-00048 Sheet 13 Rev. 1, Schematic Engine Control D13 Diesel Generator 121 Limerick Drawing M-071-00048 Sheet 16 Rev. 0, Schematic Engine Control D14 Diesel Generator 122 Limerick Drawing M-071-00048 Sheet 17 Rev. 3, Schematic Engine Control D14 Diesel Generator Page 29of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 123 Limerick Drawing M-071-00048 Sheet 18 Rev. 1, Schematic Engine Control D14 Diesel Generator 124 Limerick Drawing M-071-00048 Sheet 21 Rev. 0, Schematic Engine Control D21  Diesel Generator 125 Limerick Drawing M-071-00048 Sheet 22 Rev. 3, Schematic Engine Control D21  Diesel Generator 126 Limerick Drawing M-071-00048 Sheet 23 Rev. 1, Schematic Engine Control D21  Diesel Generator 127 Limerick Drawing M-071-00048 Sheet 26 Rev. 0, Schematic Engine Control D22  Diesel Generator 128 Limerick Drawing M-071-00048 Sheet 27 Rev. 3, Schematic Engine Control D22  Diesel Generator 129 Limerick Drawing M-071-00048 Sheet 28 Rev. 1, Schematic Engine Control D22  Diesel Generator 130 Limerick Drawing M-071-00048 Sheet 31 Rev. 0, Schematic Engine Control D23  Diesel Generator 131 Limerick Drawing M-071-00048 Sheet 32 Rev. 3, Schematic Engine Control D23  Diesel Generator 132 Limerick Drawing M-071-00048 Sheet 33 Rev. 1, Schematic Engine Control D23  Diesel Generator 133 Limerick Drawing M-071-00048 Sheet 36 Rev. 0, Schematic Engine Control D24 Diesel Generator 134 Limerick Drawing M-071-00048 Sheet 37 Rev. 3, Schematic Engine Control D24 Diesel Generator 135 Limerick Drawing M-071-00048 Sheet 38 Rev. 1, Schematic Engine Control D24 Diesel Generator 136 Limerick Drawing E-017-00012 Sheet 1Rev.11, Diagram - Schematic Arrangement 130 K300 and 400 Chargers 137 Limerick Drawing E-017-00014 Sheet 1 Rev. 9, Diagram - Schematic Arrangement 130 HK75/100F3 Chargers 138 Limerick Drawing E-017-00065 Sheet 1 Rev. 2, High Voltage Shutdown with Time Delay Universal PC Board 139 Limerick Drawing E-0032 Sheet 1 Rev. 64, Single Line Meter and Relay Diagram Uninterruptible AC, RPS, UPS, Computer 140 Limerick Drawing N-OOE-72-00010 Sheet 1Rev.1, Power Stage Wiring 30KVA Inverter Solid State Switch 1AD160 141 Limerick Drawing E-0032 Sheet 2 Rev. 39, Single Line Meter and Relay Diagram Un interruptible AC System 142 Limerick Drawing N-OOE-72-00015 Sheet 1 Rev. 1, Power Stage Wiring 30KVA Inverter Solid State Switch 1BD160 143 Limerick Drawing M-0020 Sheet 6 Rev. 52, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Starting Air System Unit 1) 144 Limerick Drawing M-0020 Sheet 12 Rev. 16, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Starting Air System Unit 2)
Page 30of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 145 Limerick Drawing M-0020 Sheet 8 Rev. 23, Piping and Instrument Diagram Fuel and Diesel Oil Storange and Transfer (Combustion Air Intake and Exhaust System Unit 1) 146 Limerick Drawing M-0020 Sheet 14 Rev. 15, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Combustion Air Intake and Exhaust System Unit 2) 147 Limerick Drawing M-0020 Sheet 7 Rev. 53, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Lube Oil System Unit 1) 148 Limerick Drawing M-0020 Sheet 13 Rev. 18, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Lube Oil System Unit 2) 149 Limerick Drawing M-0020 Sheet 3 Rev. 39, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Fuel Oil and Transfer System Unit 1) 150 Limerick Drawing M-0020 Sheet 9 Rev . 17, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Fuel Oil and Transfer System Unit 2) 151 Limerick Drawing M-071-00048 Sheet 5 Rev. 21, Schematic Engine Control Dll Diesel Generator 152 Limerick Drawing M-071-00048 Sheet 10 Rev. 1, Schematic Engine Control D12 Diesel Generator 153 Limerick Drawing M-071-00048 Sheet 15 Rev. 1, Schematic Engine Control D13 Diesel Generator 154 Limerick Drawing M-071-00048 Sheet 20 Rev. 1, Schematic Engine Control D14 Diesel Generator 155 Limerick Drawing M-071-00048 Sheet 25 Rev. 1, Schematic Engine Control D21 Diesel Generator 156 Limerick Drawing M-071-00048 Sheet 30 Rev. 1, Schematic Engine Control D22 Diesel Generator 157 Limerick Drawing M-071-00048 Sheet 35 Rev. 1, Schematic Engine Control 023 Diesel Generator 158 Limerick Drawing M-071-00048 Sheet 40 Rev. 1, Schematic Engine Control 024 Diesel Generator 159 Limerick Drawing M-0020 Sheet 4 Rev. 46, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 1) 160 Limerick Drawing M-0020 Sheet 5 Rev. 44, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 1) 161 Limerick Drawing M -0020 Sheet 10 Rev. 51, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Coling Water System Unit 2) 162 Limerick Drawing M-0020 Sheet 11 Rev. 8, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 2) 163 Limerick Drawing M -0011Sheet1 Rev. 86, Piping and Instrument Diagram Emergency Service Water (Unit 1, Unit 2, and Common) 164 Limerick Drawing E-0321 Sheet 2 Rev. 19, Schematic Diagram Emergency Service Water Pumps 165 Limerick Drawing E-0321Sheet3 Rev. 19, Schematic Diagram Emergency Service Water Pumps 166 Limerick Drawing E-0321Sheet5 Rev. 17, Schematic Diagram Emergency Service Water Pumps Page 31of110
 
15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 167 Limerick Drawing M-0081Sheet1 Rev. 31, Piping and Instrument Diagram Miscellaneous Structures HVAC 168 Limerick Drawing M-0081 Sheet 3 Rev. 15, Piping and Instrument Diagram Miscellaneous Structures HVAC (Unit 2 and Common) 169 Limerick Drawing E-0490 Sheet 1 Rev. 16, Schematic Diagram Diesel Generator Ventilation Air Exhaust Fans and Auxiliary Control Units 1 and 2 170 Limerick Drawing E-0490 Sheet 2 Rev. 10, Schematic Diagram Diesel Generator Ventilation Air Exhaust Fans and Auxiliary Control Units 1 and 2 171 Limerick Drawing E-0163 Sheet 1 Rev. 18, Schematic Diagram - Safeguard Buses - Safeguard Load Center 172 Limerick Drawing E-0163 Sheet 2 Rev. 3, Schematic Diagram - Safeguard Buses - Safeguard Load Center 173 Limerick Drawing E-0162 Sheet 1Rev.13, Schematic Diagram-Safeguard Buses - Dl44 and D244 Page 32of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 A Representative Sample Component Evaluations The following sample calculation is extracted from Reference [17).
Notes:
: 1. Reference citations within the sample calculation are per the Ref. [17) reference section shown on the following page .
: 2. This sample calculation contains evaluations of sample high-frequency-sensitive components per the methodologies of both the EPRI high-frequency guidance [8) and the flexible coping strategies guidance document NEI 12-06 [16).
Page 33 of 11 O
 
15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 S&A Cale. No.: 15C4345-CAL-001, Rev. 2                                      Sheet 9 of 20
 
==Title:==
High Frequency Functional Confirmation and      Prepared: FG    Date: 10/27/16 Fragility Evaluation of Components              Reviewed: MD    Date: 10/27/16 St""""""1&Aisociates 6      REFERENCES
: 1.      Codes. Guidance. and Standards 1.1. EPRI 3002004396. " High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation ." July 2015.
1.2. EPRI 3002002997. "High Frequency Program : High Frequency Testing Summary." September 2014.
1.3. Not Used 1.4. NEI 12-06, Appendix H, Rev. 2, "Diverse and Flexible Coping Strategies (FLEX) Implementation Guide."
1.5. IEEE 344-1975 "IEEE Recommended Practices for Seismic Qualification of Class lE Equipment for Nuclear Power Generating Stations" 1.6. SQUG GIP 3A, "Generic Implementation Procedure (GIP) for Seismic Verification of Nuclear Plant Equipment", December 2001 1.7. EPRI NP-7147-SL, "Seismic Ruggedness of Relays", August 1991 1.8. EPRI NP-7147-SL, SQUG Advisory 2004-02. "Relay GERS Corrections", September 10, 2004 1.9. EPRI NP-7147-SLV2, Addendum 1, "Seismic Ruggedness of Relays", September 1993 1.10. ANSI/IEEE C37.98-1987, "An American National Standard IEEE Standard Seismic Testing of Relays."
January 15, 1988 1.11. EPRI NP-6041-SL, Rev. 1, "A Methodology for Assessment of Nuclear Power Plant Seismic Margin",
August 1991 1.12. EPRI NP-7147-SLV2, Addendum 2, "Seismic Ruggedness of Relays", April 1995
: 2.      Nuclear Regulatory Commission Documents 2.1. Limerick Generating Station Units 1 & 2 Seismic Hazard and Screening Report, Rev. 0, NRC Docket No.
STN 50-352 & STN 50-353, Correspondence No. RS-14-069
: 3.      Station Documents 3.1. Limerick Drawing C-0409, Rev. 33, "Control Room Area, Foundations, Wall Elevations Area 8" 3.2 . General Electric Report GE-101, Rev. 2, "GE Dynamic Qualification Report for Class lE Control Room Panels" 3.3. General Electric Report GE-201, Rev. 2, "GE Dynamic Qualification Report for Class lE Control Room Panels" 3.4. Limerick Drawing C-0682, Rev. 11, "Diesel Generator Building Unit 2 Wall Elevation & Sections" 3.5. Limerick Report D-0014, Rev. 7, "Dynamic Qualification Book", Volumes 1-3.
3.6. Limerick Report D-0007, Rev. 10, "Dynamic Qualification Book", Volumes 1-2.
3.7 . Not Used 3.8. Limerick Report D-0015, Rev. 12, "Dynamic Qualification Book", Volumes 1-4.
: 4.      S&A Documents 4.1. 15C4345-RPT-001, Rev. 3, "Selection of Relays and Switches for High Frequency Seismic Evaluation."
: 5.      Other Documents 5.1. TE Connectivity, Qualification Test Report 501-529, "Nuclear Environmental Qualification Test Report on Agastat EGP, EML and ETR Control Relays by Control Products Division, Amerace Corporation" 5.2 . GE Multilin IAC Time-Overcurrent Brochure, "Time-overcurrent protection of AC circuits and apparatus." (See Attachment E) 5.3 . Agastat Nuclear Qualified Control Relays, dated 4/24/2002 "Series EGP/EML/ETR" (See Attachment F)
Page 34 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No. : 1SC4345-CAL-001, Rev. 2                                          Sheet 12 of 20 Title :  High Frequency Functional Confirmation and            Prepared : FG  Date: 10/27/16 Fragility Evaluation of Components                  Reviewed : MD    Date: 10/27/16 Stevenson & As.scxiates 8              ANALYSIS (cont'd) 8.2            High-Frequency Seismic Demand Calculate the high-frequency seismic demand on the components per the methodology from Ref. 1.1 .
Sample calculations for the high-frequency seismic demand of components PIS-050-1 N653 located in Unit 1 and E51A-K10 located in Unit 1 are presented below. A table that calculates the high-frequency seismic demand for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A , Table A-2 of this calculation.
8.2.1          Horizontal Seismic Demand The horizontal site-specific GMRS for Limerick is per Ref. 2.1. GMRS data can be found in Attachment B of this calculation.
Determine the peak acceleration of the horizontal GMRS between 15 Hz and 40 Hz .
Peak acceleration of horizontal GMRS                        S~MRS := 0.381 g              (at 15 Hz) between 15 Hz and 40 Hz (Ref. 2.1; see Attachment B of this calculation):
Calculate the horizontal in-structure amplification factor based on the distance between the bottom of the foundation elevation and the subject floor elevation.
Bottom of Deepest Foundation Elevation :                    Elfound := 174 *ft (Ref. 2.1, Table 2.3.1-1, Note C)
Component Floor Elevation (See Table A-1 ):                Elcomp :- 289 *ft Components PIS-050-1 N653 and E51A-K10 are both located in the Control Enclosure building at elevation 289'.
Distance Between Component Floor and                        hcomp := ELcomp - Elfound - 115.00 *ft Foundation Elevation:
Page 35 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2                                          Sheet 13 of 20
 
==Title:==
High Frequency Functional Confirmation and              Prepared : FG  Date: 10/27/16 Fragility Evaluation of Components                      Reviewed: MD    Date: 10/27/16 Stevenson & A5scc:iates 8            ANALYSIS (cont'd) 8.2            High-Frequency Seismic Demand (cont'd)
B.2.1          Horizontal Seismic Demand (cont'd)
Work the distance between the component floor and foundation with Ref. 1.1, Fig. 4-3 to calculate the horizontal in-structure amplification factor.
2.1 - 1.2            1 Slope of Amplification Factor Line,                  mh :=            = 0.0225 *-
Oft < hcomp < 4Dft                                          40ft - Oft            ft Intercept of Amplification Factor Line, Oft < hcomp < 40ft Horizontal In-Structure Amplification Factor:
AF SH(hcomp) :=    I(mh
* hcomp + bh) if hcomp 2.1  otherwise s 40ft Calculate the horizontal in-cabinet amplification factor based on the type of cabinet that contains the subject component.
Type of Cabinet (per Ref. 3.2 and 3.3)              cab := "Control Cabinet" (enter "MCC", "Switchgear", "Control Cabinet", or "Rigid"):
Horizontal In-Cabinet Amplification Factor        AFc.h(cab) :=      3.6 if cab= "MCC" (Ref. 1.1, p. 4-13):
7.2 if cab = "Switchgear" 4.5 if cab = "Control Cabinet" 1.0 if cab = "Rigid" AFc.h(cab) = 4.5 Multiply the peak horizontal GMRS acceleration between by the horizontal in-structure and in-cabinet amplification factors to determine the in-cabinet response spectrum demand on the components .
Horizontal In-Cabinet Response Spectrum (Ref. 1.1, p. 4-12, Eq . 4-1a):
Note that the horizontal seismic demand is the same for both components PIS-050-1 N653 and E51A-K10.
Page 36 of 110
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2                                              Sheet 14 of 20
 
==Title:==
High Frequency Functional Confirmation and                Prepared: FG      Date : 10/27/16 Fragility Evaluation of Components                      Reviewed: MD        Date: 10/27/16 Stevenson & As.scciiltes 8              ANALYSIS (cont'd) 8.2            High-Frequency Seismic Demand (cont'd)
B.2.2          Vertical Seismic Demand Determine the peak acceleration of the horizontal GMRS between 15 Hz and 40 Hz.
Peak Acceleration of Horizontal GMRS                        S~MRS - 0.381 .g (at 15 Hz)
Between 15 Hz and 40 Hz (See Sect. 8. 2.1 of this Calculation)
Obtain the peak ground acceleration (PGA) of the horizontal GMRS from Ref. 2.1 (See Attachment B of this calculation).
Peak Ground Acceleration (GMRS):                          PGAGMRS :"" 0.193g Calculate the shear wave velocity traveling from a depth of 30m to the surface of the site            01 530 ) from Ref. 1.1 and Attachment C.
(30m)
Shear Wave Velocity:
Vs30  =  1:(  di .)
VSI where, di: Thickness of the layer (ft)
V si: Shear wave velocity of the layer (ft/s)
Per Attachment C, the sum of thickness of the layer over shear wave velocity of the layer is 0.0288 sec.
30m                  ft Shear Wave Velocity:                                        v    :=                = 3418 *-
s3o    0.028Bsec              sec Page 37 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA Stevenson & Associates S&A Cale. No.: 15C4345-CAL-001, Rev. 2
 
==Title:==
High Frequency Functional Confirmation and Fragility Evaluation of Components Prepared : FG Reviewed: MD Sheet 15 of 20 Date: 10/27/16 Date: 10/27/16 8            ANALYSIS (cont'd) 8.2          High-Frequency Seismic Demand (cont'd) 8.2.2        Vertical Seismic Demand (cont'd)
Work the PGA and shear wave velocity with Ref. 1.1, Table 3-1 to determine the soil class of the site. Based on the PGA of 0.1939 and shear wave velocity of 3418ft/sec at Limerick, the site soil class is B-Hard.
Work the site soil class with Ref. 1.1, Table 3-2 to determine the mean vertical vs. horizontal GMRS ratios (V/H) at each spectral frequency. Multiply the V/H ratio at each frequency between 15Hz and 40Hz by the corresponding horizontal GMRS acceleration at each frequency between 15Hz and 40Hz to calculate the vertical GMRS .
See Attachment B for a table that calculates the vertical GMRS (equal to (V/H) x horizontal GMRS) between 15Hz and 40Hz.
Determine the peak acceleration of the vertical GMRS (SAvGMRs) between frequencies of 15Hz and 40Hz. (By inspection of Attachment B, the SAvGMRs occurs at 15Hz.)
V/H Ratio at 15Hz                                          VH := 0.68 (See Attachment B of this calculation):
Horizontal GMRS at Frequency of Peak                      HGMRS :- 0.3819 Vertical GMRS (at 15Hz)
(See Attachment B of this calculation):
Peak Acceleration of Vertical GMRS                        SAvGMRS := VH *HGMRS -= 0.259*9        (at 15 Hz)
Between 15 Hz and 40 Hz:
A plot of horizontal and vertical GMRS is provided in Attachment B of this calculation.
Page 38 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 15C4345-CAL-001, Rev. 2                                            Sheet 16 of 20 Title :  High Frequency Functional Confirmation and              Prepared : FG    Date: 10/27/16 Fragility Evaluation of Components                    Reviewed : MD    Date: 10/27/16 Stevenson & As.soc:iates 8              ANALYSIS (cont'd) 8.2            High-Frequency Seismic Demand (cont'd) 8.2.2          Vertical Seismic Demand (cont'd)
Calculate the vertical in-structure amplification factor based on the distance between the plant foundation elevation and the subject floor elevation.
Distance Between Component Floor                    hcomp  = 115.QQ .ft and Foundation (See Sect. 8.2.1 of this Calculation):
Work the distance between the component floor and foundation with Ref. 1.1, Fig . 4-4 to calculate the vertical in-structure amplification factor.
2.7    1.0          1 Slope of Amplification Factor Line:                mv : ~              - 0.017 *-
1OD ft - Oft          ft Intercept of Amplification Factor Line:
Vertical In-Structure Amplification Factor:        AF SV :- mv* hcomp + bv    = 2.96 Per Ref. 1.1, the vertical in-cabinet amplification factor is 4. 7 regardless of cabinet type.
Vertical In-Cabinet Amplification Factor:
Multiply the peak vertical GMRS acceleration between by the vertical in-structure and in-cabinet amplification factors to determine the in-cabinet response spectrum demand on the component.
Vertical In-Cabinet Response Spectrum (Ref. 1.1, p. 4-12, Eq. 4-1b):                      ICRSc.v :: AFsv*AFc.v *SAvGMRS        = 3.60 *g Note that the vertical seismic demand is the same for both components PIS-050-1 N653 and E51A-K1 DA.
Page 39 of 110
 
15(4345-RPT-002, Rev. a Correspondence No.: RS-16-177 SA S&A Cale. No.: 15C4345-CAL-001, Rev. 2                                        Sheet 17 of 20
 
==Title:==
High Frequency Functional Confirmation and          Prepared : FG  Date : 10/27/16 Fragility Evaluation of Components                  Reviewed: MD    Date : 10/27/16 Steven.son & Associates 8            ANALYSIS (cont'd) 8.3          High-Frequency Seismic Capacity A sample calculation for the high-frequency seismic capacity of components PIS-050-1 N653 and E51A-K10 located in Unit 1 is presented here. A table that calculates the high-frequency seismic capacities for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation.
8.3.1        Seismic Test Capacity The high frequency seismic capacity of a component can be determined from the EPRI High Frequency Testing Program (Ref. 1.2) or other broad banded low frequency capacity data such as the Generic Equipment Ruggedness Spectra (GERS) or other qualification reports.
The model for component PIS-050-1 N653, a Rosemount 510DU2 trip unit per Table A-1 , was not tested as part of the Ref. 1.2 high-frequency testing program. Attachment A (Group 1) provides a seismic capacity calculation for Rosemount 510DU2 trip unit based on Limerick Seismic Report GE-101 (Ref. 3.20). The seismic capacity was calculated in Attachment A to be 11. 62g for component Pl S-050-1 N653.
The model for component E51A-K10 is an Agastat EGPB002 relay per Table A-1 . Per Ref. 5.1, Page 2, Agastat EGP and GP series relays are the same relays and the "E" (nuclear safety related) designator was added to the front. Per Ref. 1.12, Page 2-4, the lowest capacity of Agastat Model GP relay 5.0g. Note that the capacity of Agastat GP relay provided in Ref. 1.12, Page 2-4 and 2-6 is based on additional verification test level only (this capacity is not the GERS capacity, but a qualification test capacity).
11.62)                        PIS-050-1 N653 )
Seismic Test Capacity (SA*):                          SA':= (        g 5.00                        (    E51A-K10 8.3.2        Effective Spectral Test Capacity Since a qualification report was used as the capacity source for both components , there are no spectral acceleration increases and the effective spectral test capacity is equal to the seismic test capacity.
PIS-050-1 N653)
Effective Spectral Test Capacity                      SAT *-(SA'1
                                                                        .-        J-(11.62)
                                                                                  -        *g          (
(Ref. 1.1, p. 4-16):                                            SA'2    5.00                    E51A-K10 Page 40 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2                                    Sheet 18 of 20
 
==Title:==
High Frequency Functional Confirmation and        Prepared: FG    Date : 10/27/16 Fragility Evaluation of Components              Reviewed: MD    Date : 10/27/16 Stevenson & Associates 8            ANALYSIS (cont'd) 8.3          High-Frequency Seismic Capacity (cont'd) 8.3.3        Seismic Capacity Knockdown Factor Determine the seismic capacity knockdown factor for the subject component based on the type of testing used to determine the seismic capacity of the component.
Using Table 4-2 of Ref. 1.1 and the capacity sources from Section 8.3.1 above, the knockdown factors are chosen as :
PIS-050-1 N653)
Seismic Capacity Knockdown Factor:                  F := (1 .20 )
k    1.20        (  E51A-K10 8.3.4        Seismic Testing Single-Axis Correction Factor Determine the seismic testing single-axis correction factor of the subject component, which is based on whether the equipment housing to which the component is mounted has well-separated horizontal and vertical motion or not.
Per Ref. 1.1, pp. 4-18, conservatively take the FMs value as 1.0.
Single-Axis Correction Factor                        FMS := 1.0 (Ref. 1.1, pp. 4-17 to 4-18):
Page 41 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 S&A Cale. No. : 15C4345-CAL-001, Rev. 2                                        Sheet 19 of 20
 
==Title:==
High Frequency Functional Confirmation and            Prepared : FG  Date: 10/27/16 Fragility Evaluation of Components                    Reviewed: MD    Date: 10/27/16 Steven.son & As.scciates 8            ANALYSIS (cont'd) 8.3            High-Frequency Seismic Capacity for Ref. 1.1 Components (cont'd) 8.3.5          Effective Wide-Band Component Capacity Acceleration Calculate the effective wide-band component capacity acceleration per Ref. 1.1, Eq. 4-5.
Effective Wide-Band Component SAT)        (9.683)          PIS-050-1N653 )
Capacity Acceleration                                TRS :=-    -    *FMS =          *g
[ Fk                        (  E51A-K10 (Ref. 1. 1, Eq. 4-5):                                                        4.167 8.4            High-Frequency Seismic Capacity for Ref. 1.4, Appendix H Components 8.4.1          Effective Wide-Band Component Capacity Acceleration Per a review of the capacity generation methodologies of Ref. 1.1 and Ref. 1.4, App. H, Section H.5, the capacity of a Ref. 1.4 component is equal to the Ref. 1.1 effective wide-band component capacity multiplied by a factor accounting for the difference between a 1% probability of failure (C 1 %* Ref. 1.1) and a 10%
probability of failure (C 10 'A,. Ref. 1.4).
Per Ref. 1.4, App. H, Table H.1, use the C 10 % vs . C1 % ratio from the Realistic Lower Bound Case for components .
c10',, vs . c,% ratio                                  c 10 :=- 1.36 Effective wide-band component capacity                                          13.169)        PIS-050-1N653 )
TRS1 4 := TRS*C10 -' (            *g  (
acceleration (Ref. 1.4, App. H, Sect. H.5)                    .                5.667            E51A-K10 Page 42 of 110
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No. : 15C4345-CAL-001, Rev. 2                                      Sheet 20 of 20
 
==Title:==
High Frequency Functional Confirmation and          Prepared : FG  Date : 10/27/16 Fragility Evaluation of Components                  Reviewed: MD    Date: 10/27/16 Stevenson & Associates 8            ANALYSIS (cont'd) 8.5          Component (Ref. 1.1) High-Frequency Margin Calculate the high-frequency seismic margin for components per Ref. 1.1, Eq. 4-6.
A sample calculation for the high-frequency seismic demand of components PIS-050-1 N653 and E51A-K10 is presented here. A table that calculates the high-frequency seismic margin for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation .
TRS    (2.689)  > 1.0, O.K.    (PIS-050-1N653)
Horizontal seismic margin (Ref. 1.1, Eq. 4-6):
ICRSc.h "' 1.157    > 1.0, O.K.          E51A-K10 TRS    (2.691)  > 1.0, O.K.    ( PIS-050-1 N653)
Vertical seismic margin (Ref. 1.1, Eq. 4-6):
ICRSc.v =  1.158    > 1.0, O.K.          E51A-K10 Both the horizontal and vertical seismic margins for PIS-050-1 N653 and E51A-K10 are greater than 1.00; indicating that these components are adequate for high frequency seismic spectral ground motion for its Ref.
1.1 functions .
8.6          Component (Ref. 1.4) High-Frequency Margin Calculate the high-frequency seismic margin for Ref. 1.4 components per Ref. 1.1, Eq. 4-6.
A sample calculation for the high-frequency seismic demand of component components PIS-050-1 N653 and E51A-K10 is presented here. A table that calculates the high-frequency seismic margin for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation.
TRS1 *4 = (3 .658)  > 1.0, O.K.      PIS-050-1 N653 )
Horizontal seismic margin (Ref. 1.1, Eq. 4-6):
ICRSc.h    1.574    > 1.0, O.K.    (    E51A-K10 TRS1 .4  (3.660)    > 1.0, O.K.      PIS-050-1 N653)
Vertical seismic margin (Ref. 1.1, Eq. 4-6):
ICRSc.v =  1.575    > 1.0, O.K.    (    E51A-K10 Both the horizontal and vertical seismic margins for PIS-050-1 N653 and E51A-K10 are greater than 1.00; therefore, these components are adequate for high-frequency seismic spectral ground motion for its Ref. 1.4 functions.
Page 43 of 110
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 B Components Identified for High Frequency Confirmation Table B-1: Components Identified for High Frequency Confirmation
    -        .-                        Component                                        Enclosure                                Component Evaluation
                    -                                                                                                  Floor No. Unit                                                                                                  Building              Basis for      Evaluation ID        Type  System  Function            Manufacturer Model No. ID          Type            Elev. {ft)
PIS-049-
                      ' Control  Core    RCIC Steam Pressure                                      Control  Control Capacity Qualification Result 1    1                                                        Rosemount    510DU1  10-C617                            289                      Cap> Dem 1N658A        Relay  Cooling  Indicating Switch                                          Cab. Enclosure                Test PIS-049-    Control  Core    RCIC Steam Pressure                                      Control  Control              Qualification 2    1                                                        Rosemount  710DUOIT  10-C640                            289                      Cap> Dem 1N658C        Relay  Cooling  Indicating Switch                                          Cab. Enclosure                Test PIS-049-    Control  Core    RCIC Steam Pressure                                      Control  Control              Qualification 3    1                                                        Rosemount    510DU1  10-C617                            289                      Cap> Dem 1N658E        Relay  Cooling  Indicating Switch                                          Cab. Enclosure                Test PIS-049-    Control  Core    RCIC Steam Pressure                                      Control  Control              Qualification 4    1                                                        Rosemount    510DU1  10-C640                            289                      Cap> Dem 1N658G        Relay  Cooling  Indicating Switch                                          Cab. Enclosure                Test PIS-050-    Control  Core    RCIC Pump Suction                                        Control  Control              Qualification 5  1                                                        Rosemount    510DU2  10-C617                            289                      Cap> Dem 1N653        Relay  Cooling  Header                                                    Cab. Enclosure                Test PIS-050-    Control  Core    RCIC Turbine Exhaust                                    Control  Control              Qualification 6  1                                                        Rosemount    510DU1  10-C617                            289                      Cap> Dem 1N655A        Relay  Cooling  Line Vent                                                  Cab. Enclosure                Test PIS-050-    Control  Core    RCIC Turbine Exhaust                                    Control  Control              Qualification 7  1                                                        Rosemount    510DU1  10-C640                            289                      Cap> Dem 1N655C        Relay  Cooling  Line Vent                                                  Cab. Enclosure                Test PIS-050-    Control  Core    RCIC Turbine Exhaust                                    Control  Control              Qualification 8  1                                                        Rosemount    510DU1  10-C617                            289                      Cap> Dem 1N655E        Relay  Cooling  Line Vent                                                  Cab. Enclosure                Test PIS-050-    Control  Core  RCIC Turbine Exhaust                                      Control  Control              Qualification 9  1                                                        Rosemount    510DU1  10-C640                            289                      Cap>Dem 1N655G        Relay  Cooling  Line Vent                                                  Cab. Enclosure                Test PIS-050-    Control  Core  RCIC Pump Turbine                                        Control  Control              Qualification 10  1                                                        Rosemount    510DU2  10-C617                            289                      Cap> Dem 1N656A        Relay  Cooling Exhaust                                                    Cab. Enclosure                Test PIS-050-    Control  Core  RCIC Pump Turbine                                        Control  Control              Qualification 11  1                                                        Rosemount    510DU2  10-C617                            289                      Cap> Dem 1N656E        Relay  Cooling Exhaust                                                    Cab. Enclosure                Test PIS-049-    Control  Core  RCIC Steam Pressure                                      Control  Control              Qualification 12  2                                                        Rosemount    510DU1  20-C617                          289                        Cap> Dem 2N658A        Relay  Cooling Indicating Switch                                          Cab. Enclosure                Test PIS-049-    Control  Core  RCIC Steam Pressure                                      Control  Control              Qualification 13  2                                                        Rosemount  710DUOIT  20-C640                          289                        Cap> Dem 2N658C        Relay  Cooling Indicating Switch                                          Cab. Enclosure                Test PIS-049-    Control  Core  RCIC Steam Pressure                                      Control  Control              Qualification 14  2                                                        Rosemount    510DU1  20-C617                          289                        Cap> Dem 2N658E        Relay  Cooling Indicating Switch                                          Cab. Enclosure                Test Page 44 of 110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 1~~.t~                                                                          ~S~f B~ll~~--,
Component                                                                          Component Evaluation I                                                                                                              Floor No.
110 I ' Type_] I~yste~ J~ctlon            ~ [Manufactu~ Model No.          Type              Elev. (ft)
                                                                                                                            'Basis for CaDacltv Evaluation Result PIS-049-  Control    Core    RCIC Steam Pressure                              Control  Control              Qualification 15      2                                                        Rosemount 710DUOTI  20-C640                      289                      Cap> Dem 2N658G      Relay  Cooling  Indicating Switch                                  Cab. Enclosure                Test PIS-050-  Control    Core    RCIC Pump Suction                                Control  Control              Qualification 16      2                                                        Rosemount 710DUOTI  20-C617                      289                      Cap> Dem 2N653      Relay  Cooling  Header                                            Cab. Enclosure                Test PIS-OSO-  Control    Core    RCIC Turbine Exhaust                              Control  Control              Qualification 17      2                                                        Rosemount  510DU1  20-C617                      289                      Cap> Dem 2N655A      Relay  Cooling  Line Vent                                          Cab. Enclosure                Test PIS-050-  Control    Core    RCIC Turbine Exhaust                              Control  Control              Qualification 18      2                                                        Rosemount 710DUOTI  20-C640                      289                      Cap> Dem 2N655C      Relay  Cooling Line Vent                                          Cab. Enclosure                Test PIS-050-  Control    Core    RCIC Turbine Exhaust                              Control  Control              Qualification 19      2                                                        Rosemount 710DUOTI  20-C617                      289                      Cap> Dem 2N655E      Relay  Cooling Line Vent                                          Cab. Enclosure                Test PIS-050-    Control    Core    RCIC Turbine Exhaust                              Control  Control              Qualification 20    2                                                          Rosemount  510DU2  20-C640                      289                      Cap> Dem 2N655G      Relay  Cooling  Line Vent                                          Cab _  Enclosure                Test PIS-050-  Control    Core    RCIC Pump Turbine                                Control  Control              Qualification 21    2                                                          Rosemount 710DUOTI  20-C617                      289                      Cap> Dem 2N656A      Relay  Cooling Exhaust                                            Cab. Enclosure                Test PIS-050-    Control    Core  RCIC Pump Turbine                                  Control  Control              Qualification 22    2                                                          Rosemount 710DUOTI  20-C617                      289                      Cap> Dem 2N656E      Relay  Cooling Exhaust                                            Cab. Enclosure                Test RCIC Pump Suction Pressure Relay Control    Core                                                      Control  Control              Qualification 23    1    E51A-K10                      Energize on Pressure    Agastat  EGPB002  10-C621                      289                      Cap> Dem Relay  Cooling                                                    Cab. Enclosure                Test On Vacuum Less than Set-point RCIC Relay- Energize on Turbine Control    Core                                                      Control  Control              Qualification 24    1    E51A-K11A                      Diaphragm Exhaust      Agastat  EGPB002  10-C621                      289                      Cap> Dem Relay  Cooling                                                    Cab. Enclosure                Test Pressure Above Set-point RCIC Relay - Energize On Turbine Control    Core                                                      Control  Control              Qualification 25    1    E51A-K11C                      Diaphragm Exhaust      Agastat  EGPB002  10-C640                      289                        Cap> Dem Relay  Cooling                                                    Cab. Enclosure                Test Pressure Above Set-Point RCIC RELAY-Energize on Turbine Control    Core                                                      Control  Control              Qualification 26    1    E51A-K12A                      Diaphragm Exhaust      Agastat  EGPB002  10-C621                      289                        Cap> Dem Relay    Cooling                                                    Cab. Enclosure                Test Pressure Above Set-point Page 45 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation "El[
Component                                            'Enclosure  -                              Component Evaluation No. ' Unit ID II  Type  !! Sys;~] ! ~unction              lr Man:itact~ i ModelNo. 1    ID
                                                                                                        ~
Building] ' Elev.
Floor{ft)J  Basis for Capacity Evaluation Result RCIC Relay - Energize on Turbine Control    Core                                                                  Control  Control                Qualification 27    1  E51A-K12C                        Diaphragm Exhaust          Agastat    EGPB002    10-C640                            289                        Cap> Dem Relay    Cooling                                                                  Cab. Enclosure                  Test Pressure Above Set-Point RCIC Relay -
Control    Core    Energizes On Turbine                                          Control  Control                Qualification 28    1    E51A-K13                                                  Agastat    EGPB00 2  10-C621                            289                        Cap> Dem Relay    Cooling  Exhaust Pressure                                                Cab . Enclosure                  Test Above Set-point RCIC Relay -
Control    Core    Energizes On Turbine                                          Control  Control                Qualification 29    1    E51A-K14                                                  Agastat    EGPB00 2  10-C621                            289                        Cap> Dem Relay    Cooling  Exhau st Pressure                                              Cab. Enclosure                  Test Above Set-Point RCIC Relay -
Control    Core    Energizes On Steam                                            Control  Control                Qualification 30    1  E51A-K16A                                                  Agastat    EGPB002    10-C621                            289                        Cap> Dem Relay    Cooling  Line Pressure Below                                            Cab. Enclosure                  Test Set-poi nt RCIC Re lay -
Control    Core    Energizes On Steam                                            Control  Control                Qualification 31    1  E51A-K16C                                                  Agastat    EGPB00 2  10-C640                            289                        Cap> Dem Relay    Cooling  Line Pressure Below                                            Cab. Enclosure                  Test Set-Poi nt RCIC Re lay -
Control    Core    Energizes On Steam                                            Control  Control                Qualification 32    1  E51A-K17A                                                  Agastat    EGPB00 2  10-C621                            289                        Cap> Dem Relay    Cooling  Line Pressure Below                                            Cab. Enclosure                  Test Set-poi nt RCIC Relay -
Control    Core    Energizes On Steam                                            Control  Control                Qualification 33    1  E51A-K17C                                                  Agastat    EGPB00 2  10-C640                            289                        Cap>Dem Relay    Cooling  Line Pressure Below                                            Cab. Enclosure                  Test Set-Point Control    Core    RCIC Turbine Trip                                            Control  Control                Qualification 34    1    E51A-K28                                                  Agastat    EGPD002    10-C621                            289                        Cap> Dem Relay    Cooling  Auxiliary Relay                                                Cab. Enclosure                  Test Page 46 of 110
 
15C4345-RPT-002, Rev . a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
[~n:J [= ro l [_rvpe :! ~te~J I                                                              ~ ~ullding !
I                            <lomponent                                          Enclosure                                Component Evaluation No. ,
Function            x  J~nufact~~r l Model No. ID F.loor l;lev. (ft)  Basis for capacity Evaluation Result Steam Leak Detection Relay Control  Core    (RCIC Isolation Signal                                      Control  Control                Qualification 35      1    E51A-K30A                                            Agastat    EGPD002  10-C621                            289                        Cap > Dem Relay  Cooling  Manual Isolation                                              Cab. Enclosure                  Test Relay - Valve ESl-F008)
RCIC DIV 3 Isolation Control  Core    Signal and Steam                                            Control  Control              Qualification 36      1    ES1A-K30C                                            Agastat    EGPD002  10-C640                            289                        Cap > Dem Relay  Cooling  line Detection Relay                                          Cab. Enclosure                  Test (ES1-F007)
RCIC Isolation Signal Control  Core    Manual Isolation                                            Control  Control              Qualification 37      1    E51A-K31A                                            Agastat    EGPD002  10-C621                            289                        Cap> Dem Relay  Cooling  Relay - Valve ESl-                                            Cab. Enclosure                  Test F008 RCIC Isolation Signal Control  Core    Manual Isolation                                            Control  Control              Qualification 38      1    ES1A-K31C                                            Agastat    EGPD002  10-C640                            289                        Cap> Dem Relay  Cooling  Relay- Valve ESl-                                            Cab. Enclosure                  Test F008 Control  Core    RCIC DIV 3 Isolation                                        Control  Control              Qualification 39      1    E51A-K67C                                            Agastat    EGPD002  10-C640                            289                        Cap> Dem Relay  Cooling  Signal Relay                                                  Cab. Enclosure                  Test RCIC Pump Suction Pressure Relay -
Control  Core                                                                Control  Control              Qualification 40      2      ESlA-KlO                  Energize on Pressure    Agastat    EGPB003  20-C621                            289                        Cap > Dem Relay  Cooling                                                                Cab. Enclosure                  Test on Vacuum Less than Set-point RCIC Relay - Energize on Turbine Co ntrol  Core                                                                Control  Control              Qualification 41      2    ESlA-KllA                  Diaphragm Exhaust        Agastat    EGPB003  20-C621                            289                      Cap > Dem Relay  Cooling                                                                Cab. Enclosure                  Test Pressure Above Set-Point RCIC Relay - Energize on Turbine Control  Core                                                                Control  Control              Qualification 42      2    ESlA-KllC                  Diaphragm Exhaust        Agast at    EGPB003  20-C640                            289                      Cap > Dem Relay  Cooling                                                                Cab. Enclosure                  Test Pressure Above Set-Point Page 47of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                          Enclosure                                  Component Evaluation' I      -              -                                                                                          Floor *1 No. I Unit ID    Type    System I
Function              Manufacturer Model No. ID          Type Building  I Elev. (ft)  Basis for        Evaluation
                              -                                                                                                        capacltv          Result RCIC Relay - Energize on turbine Control    Core                                                                Control  Con t rol              Qualification 43    2    E51A-K12A                      Diaphragm Exhaust      Agastat    EGPB003    20-C621                              289                        Cap> Dem Relay    Cooling                                                                Cab. Enclosure                  Test Pressure Above Set-Point RCIC Relay - Energize on Turbine Control    Core                                                                Control  Control                Qualification 44    2    E51A-K12C                      Diaphragm Exhaust      Agastat    EGPB003  20-C640                              289                        Cap> Dem Relay    Cooling                                                                Cab. Enclosure                  Test Pressure Above Set-Point RCIC Relay-Control    Core      Energizes on Turbine                                      Control  Control                Qualification 45    2      E51A-K13                                              Agastat    EGPB003  20-C621                              289                        Cap> Dem Relay    Cooling    Exhaust Pressure                                            Cab. Enclosure                  Test Above Set-Point RCIC Relay-Control    Core      Energizes on Turbine                                      Control  Control                Qualification 46    2      E51A-K14                                              Agastat    EGPB003  20-C621                              289                        Cap >Dem Relay    Cooling    Exhaust Pressure                                            Cab. Enclosure                  Test Above Set-Point RCIC RELAY-Control    Core      Energizes On Steam                                        Control  Control                Qualification 47    2    E51A-K16A                                              Agastat    EGPB003  20-C621                              289                        Cap> Dem Relay    Cooling    Line Pressure Below                                          Cab. Enclosure                  Test Set-Point RCIC Relay-Control    Core    Energizes on Steam                                          Control  Control                Qualification 48    2    E51A-K16C                                              Agastat    EGPB003  20-C640                              289                        Cap> Dem Relay    Cooling    Line Pressure Below                                          Cab. Enclosure                  Test Set-Point RCIC RELAY-Control    Core    Energizes On Steam                                          Control  Control                Qualification 49    2    E51A-K17A                                              Agastat    EGPB003  20-C621                              289                        Cap> Dem Relay    Cooling  Line Pressure Below                                          Cab. Enclosure                  Test Set-Point RCIC Relay-Control    Core    Energizes on Steam                                          Control  Control                Qualification 50    2    E51A-K17C                                              Agastat    EGPB002  20-C640                              289                        Cap> Dem Relay    Cooling  Line Pressure Below                                          Cab. Enclosure                  Test Set-Point Control    Core    RCIC Turbine Trip                                          Control  Control                Qualification 51    2      E51A-K28                                              Agastat    EGPD003  20-C621                              289                        Cap> Dem Relay    Cooling  Auxiliary Relay                                              Cab. Enclosure                  Test Page 48 of 11 O
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                              Enclosure                    ;1              Component Evaluation 1No. Unit                                                      --                                                  Bullc!lng Floor Elev. (ft)
Basis for        !;valuation ID      f,ype    System1  Function                Manufacturer Model No.      ID          Type  I Capacity I
Result Steam Leak Detection Relay Control    Core  {RCIC Isolation Signal                                        Control    Control                  Qualification S2  2    ES1A-K30A                                              Agastat    EGPD003    20-C621                                2S9                        Cap> Dem Relay    Cooling  Manual Isolation                                                Cab. Enclosure                    Test Relay- Valve ESl-FOOS)
RCIC DIV 3 Isolation Control    Core  Signal and Steam                                              Control    Control                  Qualification S3  2    ES1A-K30C                                              Agastat    EGPD003  20-C640                                2S9                        Cap> Dem Relay    Cooling  Line Detection Relay                                            Cab.
* Enclosure                    Test (ES1-F007)
RCIC Isolation Signal Control    Core  Manual Isolation                                              Control    Control                  Qualification S4  2    ES1A-K31A                                              Agastat    EGPD003    20-C621                                2S9                        Cap> Dem Relay    Cooling  Relay - Valve ESl-                                              Cab. Enclosure                    Test FOOS RCIC Isolation Signal Control    Core  Manual Isolation                                              Control    Control                  Qualification SS  2    ES1A-K31C                                              Agastat    EGPD003  20-C640                                2S9                        Cap> Dem Relay    Cooling  Relay- Valve ESl-                                              Cab. Enclosure                    Test FOOS Control    Core  RCIC DIV 3 Isolation                                          Control    Control                Qualification S6  2    ES1A-K67C                                              Agastat    EGPD003  20-C640                                2S9                        Cap> Dem Relay    Cooling Signal Relay                                                    Cab. Enclosure                    Test RCIC System Steam Control    Core                                        ETR14B3B                Control    Control                Qualification S7  1    ESlA-KlSA                    Flow Above Set-point      Agastat              10-C621                                2S9                        Cap> Dem Relay    Cooling                                      C2004002                  Cab. Enclosure                    Test Time Delay Relay RCIC System Steam Control    Core                                        ETR14B3B                Control    Control                Qualification SS  1    ESlA-KlSC                    Flow Above Set-Point      Agastat              10-C640                                289                        Cap> Dem Relay    Cooling                                      C2004002                  Cab. Enclosure                    Test Time Delay Relay RCIC System Steam Control    Core                                        ETR14B3C                Control    Control                Qua lificat1on S9  2    ESlA-KlSA                    Flow Above Set-point      Agastat              20-C621                                289                        Cap> Dem Relay    Cooling                                          003                    Cab. Enclosure                    Test Time Delay Relay RCIC System Steam Control    Core                                        ETR14B3C                Control    Control                Qualification 60  2    ESlA-KlSC                    Flow Above Set-Point      Agastat              20-C640                                289                        Cap> Dem Relay    Cooling                                          003                    Cab. Enclosure                    Test Time Delay Relay AC/DC lSO/lSl- Protective  Power  ESW Pump OAPS48                      121AC66KS                Switch    Control                Qualification 61  1                                                              GE                Dll-Bus-OS                              239                        Cap> Dem 11508A    Relay    Support Overcurrent Phase A                      A-S                    gear    Enclosure                    Test Systems Page 49 of 110
 
15C4345-RPT-002, Rev . 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
                  -                      C::omponent                                        Enclosure                              Component Evaluation Floor No. Unit                                                                                                    Bulldlng              Basis for        Evaluation ID      f  Type    System1  Function            Manufacturer M oilelNo. ID          Type            Elev. (ft)
                              ~
Capacity          Result AC/DC lS0/151-    Protective  Power  ESW Pump OAP548                  121AC66K8                Switch  Control              Qualification 62  1                                                            GE                  D11-8us-08                        239                        Cap> Dem 115088        Relay    Support  Overcurrent Phase 8                  A-S                    gear Enclosure                Test Systems AC/DC lS0/151-    Protective  Power  ESW Pump OAP548                  121AC66K8                Switch  Control              Qualification 63  1                                                            GE                  D11-8us-08                        239                        Cap> Dem 11508C        Relay    Support  Overcurrent Phase C                  A-S                    gear Enclosure                Test Systems AC/DC 150/151-    Protective  Power  ESW Pump 08PS48                  121AC66K8                Switch  Control              Qualification 64  1                                                            GE                  D12-8us-08                        239                        Cap> Dem 11608A        Relay    Support  Overcurrent Phase A                  A-S                    gear Enclosure                Test Systems AC/DC 150/151-    Protective  Power  ESW Pump 08P548                  121AC66K8                Switch  Control              Qualification 65  1                                                            GE                  D12-8us-08                        239                        Cap> Dem 116088        Relay    Support  Overcurrent Phase 8                  A-S                    gear Enclosure                Test Systems AC/DC 150/151-    Protective  Power  ESW Pump 08P548                  121AC66K8                Switch  Control              Qualification 66  1                                                            GE                  D12-8us-08                        239                        Cap> Dem 11608C        Relay    Support  Overcurrent Phase C                  A-S                    gear Enclosure                Test Systems AC/DC lS0/151-    Protective  Power  D224 Load Center                  121AC778                Switch  Control              Qualification 67  2                                                            GE                  D22-8us-05                        239                        Cap> Dem 11605A        Relay    Support  Overcurrent Phase A                812A-S                  gear Enclosure                Test Systems AC/DC 150/151-    Protective  Power  D224 Load Center                  121AC778                Switch  Control              Qualification 68  2                                                            GE                  D22-8us-05                        239                        Cap> Dem 116058        Relay    Support Overcurrent Phase 8                812A-S                  gear Enclosure                Test Systems AC/DC 150/151-    Protective  Power  D224 Load Center                  121AC778                Switch  Control              Qualification 69  2                                                            GE                  D22-8us-05                        239                        Cap> Dem 11605C        Relay    Support Overcurrent Phase C                812A-S                  gear Enclosure                Test Systems AC/DC 150/151-    Protective  Power  ESW Pump OCP548                  121AC66K8                Switch  Control              Qualification 70  2                                                            GE                  D23-8us-08                        239                        Cap> Dem 11708A        Relay    Support Overcurrent Phase A                  A-S                    gear Enclosure                Test Systems AC/DC 150/151-    Protective  Power  ESW Pump OCP548                  121AC66K8                Switch  Control              Qualification 71  2                                                            GE                  D23-8us-08                        239                        Cap> Dem 117088        Relay    Support Overcurrent Phase B                  A-S                    gear Enclosure                Test Systems Page 50of110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.
1 I Unit ID    ~ype    System r
Component Function            Manufacturer Model No.      ID Enclosure Type Building  I  Fk>or I Elev. (ft)
Component Evaluation Basis for        Evaluation 1  Capacity          Result AC/DC 150/151- Protective  Power    ESW Pump OCP548                  121AC66KB                Switch  Control                Qualification 72    2                                                          GE                D23-Bus-08                          239                        Cap> Dem 11708C    Relay    Support  Overcurrent Phase C                  A-S                    gear Enclosure                    Test Systems AC/DC Protective  Power                                    121CW51A                Switch  Control                Qualification 73    1  132-AG501                      Anti-Motoring Relay    GE                Dll-Bus-07                          239                        Cap> Dem Relay    Support                                      2A-S                    gear Enclosure                    Test Systems AC/DC Protective  Power                                    121CW51A                Switch  Control                Qualification 74    1  132-BGSOl                      Anti-Motoring Relay    GE                D12-Bus-07                          239                        Cap> Dem Relay    Support                                      2A-S                    gear Enclosure                  Test Systems AC/DC Protective  Power                                    121CW51A                Switch  Control                Qualification 75    1  132-CGSOl                      Anti-Motoring Relay    GE                Dl3-Bus-07                          239                        Cap> Dem Relay    Support                                      2A-S                    gear Enclosure                  Test Systems AC/DC Protective  Power                                    121CW51A                Switch  Control                Qualification 76    1  132-DGSOl                      Anti-Motoring Relay    GE                D14-Bus-07                          239                        Cap> Dem Relay    Support                                      2A-S                    gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power    Dll A Phase                      121JD52Al                Switch  Control                Qualification 77    1                                                          GE                Dll-Bus-07                          239                        Cap> Dem AGSOlA    Relay    Support  Differential Relay                  lA-S                    gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power    Dll B Phase                      121JD52A1                Switch  Control                Qualification 78    1                                                          GE                Dll-Bus-07                          239                          Cap> Dem AG501B    Relay    Support  Differential Relay                  1A-S                    gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power    Dll C Phase                      121JD52A1                Switch  Control                Qualification 79    1                                                          GE                Dll-Bus-07                          239                        Cap> Dem AG501C    Relay    Support  Differential Relay                  lA-S                    gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power    D12 A Phase                      121JD52Al                Switch  Control                Qualification 80    1                                                          GE                D12-Bus-07                          239                          Cap> Dem BGSOlA    Relay    Support  Differential Relay                  lA-S                    gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power    012 B Phase                      121JD52Al                Switch  Control                Qualification 81    1                                                          GE                D12-Bus-07                          239                          Cap> Dem BG501B    Relay    Support  Differential Relay                  lA-S                    gear Enclosure                  Test Systems Page51 of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component
                                                                      -                        Enclosure                              Component Evaluation I
No. I Unit I                                                                                                    Building Floor Basis for        Evaluation 110    T,y pe  I System  II Function            Manufacturer Model No. ID          Type            Elev. (ft)
Capacltv          Result I
AC/DC 187G-  Protective    Power    D12 C Phase                      121JD52Al              Switch  Control              Qualification 82    1                                                              GE                D12-Bus-07                        239                        Cap> Dem BGSOlC    Relay      Support    Differential Relay                  lA-S                  gear Enclosure                Test Systems AC/DC 187G-  Protective    Power    D13 A Phase                      121JD52A1              Switch  Control              Qualification 83    1                                                              GE                D13-Bus-07                        239                        Cap> Dem CGSOlA    Relay      Support    Differential Relay                  lA-S                  gear Enclosure                Test Systems AC/DC 187G-  Protective    Power    D13 B Phase                      121JD52A1              Switch  Control              Qualification 84    1                                                              GE                D13-Bus-07                        239                        Cap> Dem CGSOlB    Relay      Support    Differential Relay                  lA-S                  gear Enclosure                Test Systems AC/DC 187G-  Protective    Power    D13 C Phase                      121JD52Al              Switch  Control              Qualification 85    1                                                              GE                D13-Bus-07                        239                        Cap> Dem CGSOlC    Relay      Support    Differential Relay                  lA-S                  gear Enclosure                Test Systems AC/DC 187G-  Protective    Power    D14 A Phase                      121JD52Al              Switch  Control              Qualification 86    1                                                              GE                D14-Bus-07                        239                        Cap> Dem DGSOlA    Relay      Support    Differential Relay                  lA-S                  gear Enclosure                Test Systems AC/DC 187G-  Protective    Power    D14 B Phase                      121JD52Al              Switch  Control              Qualification 87    1                                                              GE                D14-Bus-07                        239                        Cap> Dem DGSOlB    Relay      Support    Differential Relay                  lA-S                  gear Enclosure                Test Systems AC/DC 187G-  Protective    Power    D14 C Phase                      121JD52Al              Switch  Control              Qualification 88    1                                                              GE                  D14-Bus-07                        239                        Cap> Dem DGSOlC    Relay      Support    Differential Relay                  lA-S                  gear Enclosure                Test Systems AC/DC Protective    Power                                      121CWS1A                Switch  Control              Qualification 89    2    132-AGSOl                        Anti-Motoring Relay    GE                  D21-Bus-07                        239                        Cap> Dem Relay      Support                                        2A-S                  gear Enclosure                Test Systems AC/DC Protective    Power                                      121CWS1A                Switch  Control              Qualification 90    2    132-BGSOl                        Anti-Motoring Relay    GE                  D22-Bus-07                        239                        Cap> Dem Relay      Support                                        2A-S                  gear Enclosure                Test Systems AC/DC Protective    Power                                      121CW51A                Switch  Control              Qualification 91    2    132-CGSOl                        Anti-Motoring Relay    GE                  D23-Bus-07                        239                        Cap> Dem Relay      Support                                        2A-S                  gear Enclosure                Test Systems Page 52 of 110
 
15C4345-RPT-002, Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
                      -              Component                                          Enclosure                1              Component Evaluation Floor No. Unit                                                                                                  Building                Basis for-      Evaluation ID      Type    System  Function            ' Manufacturer Model No. ID          Type            Elev. (ft)
Capacity          Result AC/DC Protective  Power                                      121CWS1A                Switch  Control                Qualification 92  2  132-DGSOl                    Anti-Motoring Relay      GE                D24-Bus-07                          239                        Cap> Dem Relay    Support                                        2A-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D21 A Phase                        121JD52Al              Switch  Control                Qualification 93  2                                                          GE                D21-Bus-07                          239                        Cap>Dem AGSOlA    Relay    Support  Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  021 B Phase                        121JD52Al              Switch  Control                Qualification 94  2                                                          GE                D21-Bus-07                          239                        Cap> Dem AGSOlB    Relay    Support  Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D21 C Phase                        121JD52Al              Switch  Control                Qualification 95  2                                                          GE                D21-Bus-07                          239                        Cap> Dem AGSOlC    Relay    Support  Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D22 A Phase                        121JD52Al              Switch  Control                Qualification 96  2                                                          GE                D22-Bus-07                          239                        Cap> Dem BGSOlA    Relay    Support  Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D22 B Phase                        121JD52Al              Switch  Control              Qualification 97  2                                                          GE                D22-Bus-07                        239                        Cap> Dem BGSOlB    Relay    Support  Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D22 C Phase                        121JD52Al              Switch  Control              Qualification 98  2                                                          GE                D22-Bus-07                        239                        Cap> Dem BGSOlC    Relay    Support Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D23 A Phase                        121JD52Al              Switch  Control              Qualification 99  2                                                          GE                D23-Bus-07                        239                        Cap> Dem CGSOlA    Relay    Support Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D23 B Phase                        121JD52Al              Switch  Control              Qualification 100  2                                                          GE                D23-Bus-07                        239                        Cap> Dem CGSOlB    Relay    Support Differential Relay                    lA-S                  gear Enclosure                  Test Systems AC/DC 187G-  Protective  Power  D23 C Phase                        121JDS2Al              Switch  Control              Qualification 101  2                                                          GE                023-Bus-07                        239                        Cap> Dem CGSOlC    Relay    Support Differential Relay                    lA-S                  gear Enclosure                  Test Systems Page 53 of 110
 
15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Compon_ent                                        Enclosure                              Component Evaluatlon Floor No. Unit          '                                                                            I        Bulldlng              Basis for        Evaluatlon ID      Type    System  Function            Manufacturer Model No.      ID          Type            Elev. (ft) canadtv            Result AC/DC 187G-    Protective  Power  D24 A Phase                      121JD52Al                Switch  Control              Qualification 102  2                                                          GE                D24-8us-07                          239                        Cap> Dem DG501A      Relay    Support  Differential Relay                  lA-S                    gear Enclosure                Test Systems AC/DC 187G-    Protective  Power  D24 8 Phase                      121JD52Al                Switch  Control              Qualification 103  2                                                          GE                D24-8us-07                          239                        Cap> Dem DG501B      Relay    Support  Differential Relay                  lA-S                    gear Enclosure                Test Systems AC/DC 187G-    Protective  Power  D24 C Phase                      121JD52Al                Switch  Control              Qualification 104  2                                                          GE                D24-8us-07                          239                        Cap> Dem DG501C      Relay    Support  Differential Relay                  lA-S                    gear Enclosure                Test Systems AC/DC 150/151-  Protective  Power  D114 Load Center                121AC778                Switch  Control              Qualification 105  1                                                          GE                Dll-8us-05                          239                        Cap> Dem 11505A      Relay    Support  Overcurrent Phase A              812A-S                    gear Enclosure                Test Systems AC/DC 150/151-  Protective  Power  D114 Load Center                121AC77B                Switch  Control              Qualification 106  1                                                          GE                Dll-8us-05                          239                        Cap> Dem 115058      Relay    Support  Overcurrent Phase 8              812A-S                    gear Enclosure                Test Systems AC/DC 150/151-  Protective  Power  D114 Load Center                  121AC778                Switch  Control              Qualification 107  1                                                          GE                Dll-8us-05                          239                        Cap> Dem 11505C      Relay    Support  Overcurrent Phase C              812A-S                    gear Enclosure                Test Systems AC/DC 150/151-  Protective  Power  D124 Load Center                  121AC778                Switch  Control              Qualification 108  1                                                          GE                D12-8us-05                        239                        Cap>Dem 11605A      Relay    Support  Overcurrent Phase A              812A-S                    gear Enclosure                Test Systems AC/DC 150/151-  Protective  Power  D124 Load Center                  121AC778                Switch  Control              Qualification 109  1                                                          GE                D12-8us-05                        239                        Cap> Dem 116058      Relay    Support Overcurrent Phase 8                812A-S                    gear Enclosure                Test Systems AC/DC 150/151-  Protective  Power  D124 Load Center                  121AC778                Switch  Control              Qualification 110  1                                                          GE                D12-8us-05                        239                        Cap> Dem 11605C      Relay    Support Overcurrent Phase C                812A-S                    gear Enclosure                Test Systems AC/DC 150/151-  Protective  Power  Dl34 Load Center                  121AC778                Switch  Control              Qualification 111  1                                                          GE                D13-8us-05                        239                        Cap> Dem 11705A      Relay    Support Overcurrent Phase A                812A-S                    gear Enclosure                Test Systems Page 54of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                            Enclosure                              i    Co!!Jponent Evaluation No. I ~ Unit
                              ~
                                                              -                                                Building 11  Floor Basis for      Evaluation ID      Type    System I Function              Manufacturer  Model No. ID          Type              J;lev. (ft)
                        -                                                  -                                                            Capacity          Result AC/DC 150/151- Protective  Power  D134 Load Center                    121AC77B                Switch  Control                  Qualification 112      1                                                          GE                  D13-Bus-05                          239                          Cap> Dem 117058    Relay    Support  Overcurrent Phase B                    812A-S                  gear Enclosure                      Test Systems AC/DC 150/151- Protective  Power  D134 Load Center                    121AC77B                Switch  Control                  Qualification 113      1                                                          GE                  D13-Bus-05                          239                          Cap>Dem 11705C    Relay    Support  Overcurrent Phase C                    812A-S                  gear Enclosure                      Test Systems AC/DC 150/151- Protective  Power  D144 Load Center                    121AC77B                Switch  Control                  Qualification 114      1                                                          GE                  D14-Bus-05                          239                          Cap> Dem 11805A    Relay    Support  Overcurrent Phase A                  812A-S                  gear Enclosure                      Test Systems AC/DC 150/151- Protective  Power  D144 Load Center                    121AC77B                Switch  Control                  Qualification 115      1                                                          GE                  D14-0us-05                          239                          Cap> Dem 118050    Relay    Support  Overcurrent Phase 0                  812A-S                  gear Enclosure                      Test Systems AC/DC 150/151- Protective  Power  D144 Load Center                    121AC770                Switch  Control                  Qualification 116      1                                                          GE                  D14-0us-05                          239                          Cap> Dem 11805C    Relay    Support  Overcurrent Phase C                  812A-S                  gear Enclosure                      Test Systems AC/DC 150/151- Protective  Power  D214 Load Center                    121AC770                Switch  Control                  Qualification 117      2                                                          GE                  D21-0us-05                          239                          Cap> Dem 11505A    Relay    Support  Overcurrent Phase A                  812A-S                  gear Enclosure                      Test Systems AC/DC 150/151- Protective  Power  D214 Load Center                    121AC77B                Switch  Control                  Qualification 118      2                                                          GE                  D21-Bus-05                          239                          Cap> Dem 115050    Relay    Support  Overcurrent Phase 0                  812A-S                  gear Enclosure                      Test Systems AC/DC 150/151- Protective  Power  D214 Load Center                    121AC77B                Switch  Control                  Qualification 119      2                                                          GE                  D21-Bus-05                          239                          Cap> Dem 11505C    Relay    Support  Overcurrent Phase C                  812A-S                  gear Enclosure                    Test Systems AC/DC 150/151- Protective  Power  D234 Load Center                    121AC77B                Switch  Control                  Qualification 120      2                                                          GE                  D23-Bus-05                          239                          Cap> Dem 11705A    Relay    Support  Overcurrent Phase A                  812A-S                  gear Enclosure                    Test Systems AC/DC 150/151- Protective  Power  D234 Load Center                    121AC770                Switch  Control                  Qualification 121      2                                                          GE                  D23-0us-05                          239                          Cap> Dem 117058    Relay    Support  Overcurrent Phase B                  812A-S                  gear Enclosure                    Test Systems Page 55 of 110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS- 16-177 Table B-1: Components Identified for High Frequency Confirmation B~dlng I Component                                    Enclosure                                Component Evaluation Floor No. ! r : n-lt l
                ~ *~_ 10    H  T,ype ' J L ~tem I~ F~nctio'!.. ! IManufa~u~~ : Model No. [~ I? ~ilrv~          l            Elev. (ft)  Basis for capacity Evaluation Result AC/DC 150/151-  Protective    Power  D234 Load Center            121AC77B                Switch    Control              Qualification 122      2                                                              GE                D23-Bus-05                          239                        Cap> Dem 11705C      Relay      Support  Overcurrent Phase C          812A-S                  gear  Enclosure                Test Systems AC/DC 150/151-  Protective    Power  0244 Load Center            121AC77B                Switch    Control              Qualification 123      2                                                              GE                D24-Bus-05                          239                        Cap>Dem 11805A      Relay      Support  Overcurrent Phase A          812A-S                  gear  Enclosure                Test Systems AC/DC 150/151-  Prot ective    Power  D244 Load Center            121AC77B                Switch    Control              Qualification 124      2                                                              GE                D24-Bus-05                          239                        Cap> Dem 118058      Rela y      Support Overcurrent Phase B          812A-S                  gear  Enclosure                Test Systems AC/DC 150/151-  Protective    Power  D244 Load Center            121AC77B                Switch    Control              Qualification 125      2                                                              GE                D24-Bus-05                          239                        Cap> Dem 11805C      Relay      Support Overcurrent Phase C          812A-5                  gear  Enclosure                Test Systems AC/DC 150/151-  Protective    Power  ESW Pump ODP548            12JAC66K8                Switch    Control              Qualification 126      2                                                              GE                D24-Bus-08                          239                        Cap> Dem 11808A      Relay      Support Overcurrent Phase A            A-S                    gear  Enclosure                Test Systems AC/DC 150/151-  Protective    Power  ESW Pump ODP548            121AC66K8                Switch    Control              Qualification 127      2                                                              GE                024-Bus-08                          239                        Cap> Dem 118088      Relay      Support Overcurrent Phase 8            A-S                    gear  Enclosure                Test Systems AC/DC 150/151-  Protective    Pow er ESW Pump ODP548            121AC66K8                Switch    Control              Qualification 128      2                                                              GE                D24-8us-08                          239                        Cap> Dem 11808C      Relay      Support Overcurrent Phase C            A-S                    gear  Enclosure                Test Systems AC/DC A117 Breaker 702 Protective    Power                              121AC53A                Switch    Control              Qualification 129      1      151-11702A                        Bus A Phase          GE                D13-Bus-02                          239                        Cap> Dem Relay      Support                                802A-S                  gear  Enclosure                Test Overcurrent Relay Systems AC/DC All 7 Breaker 702 Protect ive    Power                              121AC53A                Switch    Control              Qualification 130      1      151-11702B                        Bus B Phase          GE                013-Bus-02                          239                        Cap> Dem Relay      Support                                802A-S                  gear  Enclosure                Test Overcurrent Relay Systems AC/DC All 7 Breaker 702 Protective    Power                              121AC53A                Switch    Control              Qualification 131      1        151-11702C                        Bus C Phase          GE                D13-Bus-02                          239                        Cap > Dem Relay      Support                                802A-S                  gear  Enclosure                Test Overcurrent Relay Systems Page 56of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
                            --              Component Enclosure
                                                                                                            ,                          Component Evaluation Floor No. Unit                                                                                                        BuUdlng                Basis for        Evaluation ID      Type    f System  Function          Manufacturer ModellNo.      ID          Type              Elev. (ft)
        .J                                                                                                                            Caoadtv            Result AC/DC A117 Breaker 709 Protectrve    Power                                  12JAC53A                  Switch    Control              Qualrfication 132  1      151-11709A                      Bus A Phase          GE                  D13-Bus-09                          239                        Cap> Dem Relay      Support                                  802A-S                    gear  Enclosure                Test Overcurrent Relay Systems AC/DC A117 Breaker 709 Protective    Power                                  121AC53A                  Switch    Control              Qualification 133  1      151-11709B                      Bus B Phase          GE                  D13-Bus-09                            239                        Cap>Dem Relay      Support                                  802A-S                    gear  Enclosure                Test Overcurrent Relay Systems AC/DC All 7 Breaker 709 Protective    Power                                  121AC53A                  Switch    Control              Qualification 134  1      151-11709C                      Bus C Phase          GE                  D13-Bus-09                            239                        Cap> Dem Relay      Support                                  802A-S                    gear  Enclosure                Test Overcurrent Relay Systems AC/DC 151-    Protective    Power  Phase Overcurrent              121AC53A                  Switch    Control              Qualification 135  1                                                            GE                  Dll-Bus-07                            239                        Cap> Dem AG501A      Relay      Support  Relay Phase A                  802A-5                    gear  Enclosure                Test Systems AC/DC 151-    Protective    Power  Phase Overcurrent              12JAC53A                  Switch    Control              Qualification 136  1                                                            GE                  Dll-Bus-07                            239                        Cap> Dem AG501B      Relay      Support Relay Phase B                    802A-S                    gear  Enclosure                Test Systems AC/DC 151-    Protective    Power  Phase Overcurrent              121AC53A                  Swrtch    Control              Qualification 137  1                                                            GE                  Dll-Bus-07                            239                        Cap> Dem AG501C      Relay      Support  Relay Phase C                  802A-S                    gear  Enclosure                Test Systems AC/DC 151-    Protective    Power  Phase Overcurrent              12JAC53A                  Switch    Control              Qualification 138  1                                                            GE                  D12-Bus-07                            239                        Cap> Dem BG501A    Relay      Support Relay Phase A                    802A-S                    gear  Enclosure                Test Systems AC/DC 151-    Protective    Power  Phase Overcurrent              121AC53A                  Switch    Control              Qualification 139  1                                                            GE                  D12-Bus-07                          239                        Cap> Dem BG501B    Relay      Support Relay Phase B                    802A-S                    gear  Enclosure                Test Systems AC/DC 151-    Protective    Power  Phase Overcurrent              121AC53A                  Switch    Control              Qualification 140  1                                                            GE                  D12-Bus-07                          239                        Cap> Dem BG501C    Relay    Support  Relay Phase C                    802A-S                    gear  Enclosure                Test Systems AC/DC 151-    Protective    Power  Phase Overcurrent              121AC53A                  Switch    Control              Qualification 141  1                                                            GE                  D13-Bus-07                          239                        Cap> Dem CG501A      Relay      Support Relay Phase A                    802A-S                    gear  Enclosure                Test Systems Page 57 of 110
 
15C4345- RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation r                      I l ~lt ll                                                                                    r-Component                                                                                          Component Evaluation No.
ID
                          ~f=-  Type    *1 1iis~~ ~nctio~ =
l~nufacturer I [ M~~~. ,
Enclosure I~ [
Type_  I [ Building  I  Floor Elev. (ft}
Basis for Ca pacify Evaluation Result AC/DC 151-      Protective      Power  Phase Overcurrent                  121AC53A                Switch        Control                Qualification 142      1                                                                  GE                    D13-Bus-07                                239                        Cap> Dem CG501B        Relay        Support  Relay Phase B                        802A-S                  gear      Enclosure                  Test Systems AC/DC 151-      Protective      Power  Phase Overcurrent                  121AC53A                Switch        Control                Qualification 143      1                                                                  GE                    D13-Bus-07                                239                      Cap> Dem CG501C        Relay        Support  Relay Phase C                        802A-S                  gear      Enclosure                  Test Systems AC/DC 151-      Protective      Power  Phase Overcurrent                  121AC53A                Switch        Control                Qualification 144      1                                                                  GE                    D14-Bus-07                                239                      Cap> Dem DG501A        Relay        Support  Relay Phase A                        802A-S                  gear      Enclosu re                  Test Systems AC/DC 151-      Protective      Power  Phase Overcurrent                  121AC53A                Switch        Control                Qualification 145    1                                                                  GE                    D14-Bus-07                                239                      Cap> Dem DG501B        Relay        Support  Relay Phase B                        802A-S                  gear      Enclosure                  Test Systems AC/DC lSl-      Protective      Pow er Phase Overcurrent                  121AC53A                Switch        Control                Qualification 146    1                                                                  GE                    D14-Bus-07                                239                        Cap> Dem DG501C        Relay        Support Relay Phase C                        802A-S                  gear      Enclosure                  Test Systems AC/DC A115 Breaker 502 Protective      Power                                      121ACS3A                Switch        Control                Qualification 147    1      151-11502A                            Bus A Phase            GE                    Dll-Bus-02                                239                        Cap > Dem Relay        Support                                      802A-S                  gear      Enclosure                  Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective      Pow er                                    121AC53A                Switch        Control                Qualification 148    1      151-11502B                            Bus B Phase            GE                    Dll-Bus-02                                239                        Cap > Dem Relay        Support                                      802A-S                  gear      Enclosu re                  Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective      Pow er                                    121AC53A                Switch        Control                Qualification 149    1      151-11502C                            Bus C Phase            GE                    Dll-Bus-02                                239                        Cap> Dem Relay        Support                                      802A-S                  gear      Enclosure                    Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective      Power                                      121AC53A                Switch        Control                Qualification 150    1      151-11509A                            Bus A Phase            GE                    Dll-Bus-09                                239                        Cap> Dem Relay        Support                                      802A-S                  gear      Enclosure                    Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Prot ective      Pow er                                    121AC53A                Switch        Cont rol              Qualification 151    1      151-11509B                            Bus B Phase            GE                    Dll-Bus-09                                239                        Cap> Dem Relay        Support                                      802A-S                  gear      Enclosu re                  Test Overcurrent Relay Systems Page 58of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.
a,    ID
                ![    T,ype Protective
                              ' ~temj AC/DC Power Component Function A115 Breaker 509
[
121AC53A
                                                                                        ~
                                                              ~a~ufacturer IMod.ei~~~o. ]~      ID Enclosure I T~~.J Switch iB~;din~]
Control Floor l;lev. (ft)
Comp()nent Evaluation Basis for Capacity Qualification Evaluation Result 152 1 151-11509C                          Bus C Phase              GE                      Dll-Bus-09                            . 239                        Cap> Dem Relay      Support                                      802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective    Power                                    121AC53A                      Switch    Control                Qualification 153 1 151-11602A                          Bus A Phase              GE                      D12-Bus-02                              239                        Cap > Dem Relay      Support                                      802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective    Power                                    121AC53A                      Switch    Control                Qualification 154 1 151-11602B                          Bus B Phase              GE                      D12-Bus-02                              239                        Cap> Dem Relay      Support                                      802A-S                        gear    Enclosu re                  Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective    Power                                    121AC53A                      Switch    Control                Qualification 155 1 151-11602C                          Bus C Phase              GE                      D12-Bus-D2                              239                        Cap> Dem Relay      Support                                      802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective    Power                                    121AC53A                      Switch    Control                Qualification 156 1 151-11609A                        Bus A Phase              GE                      D12-Bus-09                              239                        Cap> Dem Relay      Support                                      802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective    Power                                    UIAC53A                      Switch    Control                Qualification 157 1 151-11609B                        Bus B Phase              GE                      D12-Bus-09                              239                        Cap> Dem Relay      Support                                      B02A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective    Power                                    121AC53A                      Switch    Control                Qualification 158 1 151-11609C                        Bus c Phase              GE                      D12-Bus-09                              239                        Cap> Dem Relay      Support                                      802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective    Power                                    121AC53A                      Switch    Control                Qualification 159 1 151-11802A                        Bus A Phase              GE                      D14-Bus-02                              239                        Cap> Dem Relay      Support                                      802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC AllB Breaker 802 Protective    Power                                    121AC53A                      Switch    Control                Qualification 160 1 151-11802B                        Bus B Phase              GE                      D14-Bus-02                              239                        Cap> Dem Relay      Support                                    802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems AC/DC All8 Breaker 802 Protective    Power                                    121AC5 3A                    Switch    Control                Qualification 161 1 151-11802C                        Bus C Phase              GE                      D14-Bus-02                              239                        Cap> Dem Relay      Support                                    802A-S                        gear    Enclosure                  Test Overcurrent Relay Systems Page 59 of 110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                      Enclosure                                Component Evaluatio_11
                                    --                                                                                      Floor No. II Unit                                                                      '                            Building                Basis for        Evaluation ID l
T,ype      System ' Function AC/DC Manufacturer Model No. ID          Type I Elev. (ft)
Capacity          Result A118 Breaker 809 Protective    Power                                  121AC53A                Switch  Control                Qualification 162    1  151-11809A                          Bus A Phase          GE                D14-Bus-09                          239                        Cap> Dem Relay      Support                                    802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A118 Breaker 809 Protective    Power                                  121AC53A                Switch  Control                Qualification 163    1  151-11809B                          Bus B Phase          GE                D14-Bus-09                          239                        Cap >Dem Relay      Support                                    802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A118 Breaker 809 Protective    Power                                  121AC53A                Switch  Control                Qualification 164    1  151-11809C                          Bus C Phase          GE                D14-Bus-09                          239                        Cap> Dem Relay    Support                                    802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A117 Breaker 702 Protective    Power                                  121AC53A                Switch  Control                Qualification 16S    2  151-11702A                          Bus A Phase          GE                D23-Bus-02                          239                        Cap> Dem Relay    Support                                      802A                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A117 Breaker 702 Protective  Power                                    121AC53A                Switch  Control              Qualification 166    2  1Sl-11702B                        Bus B Phase            GE                D23-Bus-02                        239                        Cap> Dem Relay    Support                                      802A                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A117 Breaker 702 Protective  Power                                    121AC53A                Switch  Control              Qualification 167    2  151-11702C                        Bus C Phase            GE                D23-Bus-02                        239                        Cap> Dem Relay    Support                                      802A                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC All 7 Breaker 709 Protective  Power                                    121AC53A                Switch  Control              Qualification 168    2  151-11709A                        Bus A Phase            GE                D23-Bus-09                        239                        Cap> Dem Relay    Support                                    802A-S                  gear Enclosure                  Test Overcu rrent Relay Systems AC/DC A117 Breaker 709 Protective  Power                                    121AC53A                Switch  Control              Qualification 169    2  151-11709B                        Bus B Phase            GE                D23-Bus-09                        239                        Cap> Dem Relay    Support                                    802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A117 Breaker 709 Protective  Power                                    121AC53A                Switch  Control              Qualification 170    2  151-11709C                        Bus C Phase            GE                D23-Bus-09                        239                        Cap> Dem Relay    Support                                    802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC 151-      Protective  Power    Phase Overcurrent              121AC53A                Switch  Control              Qualification 171    2                                                            GE                  D21-Bus-07                        239                        Cap> Dem AG501A      Relay    Support  Relay Phase A                    802A-S                  gear Enclosure                  Test Systems Page 60of110
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                I      Enclosure                                  Compo!ll!nt Evaluation Floor No. Unit                                                                                            Building                  Basis for      Evaluation I        ID    Type    System  Function          Manufacturer Model No.      ID          Type            I Elev. (ft) j  Capacity
    -                                                                                                                                              Result AC/DC 151-  Protective  Power  Phase Overcurrent              121ACS3A                  Switch  Control                  Qualification 172    2                                                    GE                  D21-Bus-07                          239                        Cap> Dem AG501B  Relay    Support  Relay Phase B                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              121ACS3A                  Switch  Control                  Qualification 173    2                                                    GE                  D21-Bus-07                          239                        Cap> Dem AG501C  Relay    Support  Relay Phase C                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              121ACS3A                  Switch  Control                  Qualification 174    2                                                    GE                  D22-Bus-07                          239                        Cap> Dem BG501A  Relay    Support  Relay Phase A                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              12JACS3A                  Switch  Control                  Qualification 175    2                                                    GE                  D22-Bus-07                          239                        Cap> Dem BG501B  Relay    Support  Relay Phase B                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              12JACS3A                  Switch  Control                  Qualification 176    2                                                    GE                  D22-Bus-07                          239                        Cap> Dem BG501C  Relay    Support Relay Phase C                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              12JACS3A                  Switch  Control                  Qualification 177    2                                                    GE                  D23-Bus-07                          239                        Cap>Dem CG501A  Relay    Support Relay Phase A                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              121ACS3A                  Switch  Control                  Qualification 178    2                                                    GE                  D23-Bus-07                          239                          Cap> Dem CG501B  Relay    Support Relay Phase B                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              121ACS3A                  Switch  Control                  Qualification 179    2                                                    GE                  D23-Bus-07                          239                          Cap> Dem CG501C  Relay    Support Relay Phase C                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              121ACS3A                  Switch  Control                  Qualification 180    2                                                    GE                  D24-Bus-07                          239                          Cap> Dem DG501A  Relay    Support Relay Phase A                    802A-S                    gear Enclosure                    Test Systems AC/DC 151-  Protective  Power  Phase Overcurrent              121AC53A                  Switch  Control                  Qualification 181    2                                                    GE                  D24-Bus-07                          239                          Cap> Dem DGS01B  Relay    Support Relay Phase B                    802A-S                    gear Enclosure                    Test Systems Page 61 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 1    -              -          Component                                      Enclosure                                Component Evaluation Floor No. Unit                                                                                                Building I              Basis for      I Evaluation ID      Type    System  Function          Manufacturer Model No. ID          Type            Elev. (ft)
Capacltv          Result AC/DC 151-  Protective  Power  Phase Overcurrent              121AC53A                Switch  Control                Qualification 182  2                                                          GE                D24-Bus-07                          239                        Cap> Dem DG501C    Relay    Support  Relay Phase C                    802A-S                  gear Enclosure                  Test Systems AC/DC A115 Breaker 502 Protective  Power                                  121AC53A                Switch  Control                Qualification 183  2    151-11502A                    Bus A Phase          GE                D21-Bus-02                          239                        Cap>Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective  Power                                  121AC53A                Switch  Control                Qualification 184  2    151-11502B                    Bus B Phase          GE                D21-Bus-02                          239                        Cap> Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective  Power                                  121AC53A                Switch  Control                Qualification 185  2    151-11502C                    Bus C Phase          GE                D21-Bus-02                          239                        Cap> Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective  Power                                  121AC53A                Switch  Control              Qualification 186  2    151-11509A                    Bus A Phase            GE                D21-Bus-09                        239                        Cap> Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective  Power                                  121AC53A                Switch  Control              Qualification 187  2    1Sl-11509B                    Bus B Phase            GE                D21-Bus-09                        239                        Cap>Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective  Power                                  121AC53A                Switch  Control              Qualification 188  2    151-11509C                    Bus C Phase            GE                D21-Bus-09                        239                        Cap> Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective  Power                                  121AC53A                Switch  Control              Qualification 189  2    151-11602A                    Bus A Phase            GE                D22-Bus-02                        239                        Cap >Dem Relay    Support                                    803A                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective  Power                                  121AC53A                Switch  Control              Qualification 190  2    151-11602B                    Bus B Phase            GE                D22-Bus-02                        239                        Cap> Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective  Power                                  121AC53A                Switch  Control              Qualification 191  2    151-11602C                    Bus C Phase            GE                D22-Bus-02                        239                        Cap> Dem Relay    Support                                  802A-S                  gear Enclosure                  Test Overcurrent Relay Systems Page 62 of 110
 
15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I                                          Component                                        Enclosure                                  Component Evaluation
              -                                                                                                                Floor No. Unit              I                    ' Function                                                          Building 11              Basis for      Evaluation ID            Type    System                      Manufacturer Model No.      ID      ' Type                Elev. (ft)
_j                                                                                                                  (;apacltv        Result AC/DC A116 Breaker 609 Protective  Power                                    121AC53A                Switch  Control                Qualification 192    2  151-11609A                            Bus A Phase            GE                D22-Bus-09                            239                        Cap> Dem Relay    Support                                      802A-S                  gear Enclosure                    Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective  Power                                    121AC53A                Switch  Control                Qualification 193    2  151-11609B                            Bus B Phase            GE                D22-Bus-09                            239                        Cap> Dem Relay    Support                                      802A-S                  gear Enclosure                    Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective  Power                                    121AC53A                Switch  Control                Qualification 194    2  151-11609C                            Bus C Phase            GE                D22-Bus-09                            239                        Cap> Dem Relay    Support                                      802A-S                  gear Enclosure                    Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective  Power                                    121AC53A                Switch  Control                Qualification 195    2  151-11802A                            Bus A Phase            GE                D24-Bus-02                          239                        Cap> Dem Relay    Support                                    802A-S                    gear Enclosure                    Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective  Power                                    121AC53A                Switch  Control                Qualification 196    2  151-11802B                          Bus B Phase            GE                D24-Bus-02                          239                        Cap> Dem Relay    Support                                    802A-S                    gear Enclosure                    Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective  Power                                    121AC53A                Switch  Control                Qualification 197    2  151-11802C                          Bus C Phase            GE                D24-Bus-02                          239                        Cap> Dem Relay    Support                                    802A-S                    gear Enclosure                    Test Overcurrent Relay Systems AC/DC All8 Breaker 809 Protective  Power                                    121AC53A                Switch  Control                Qualification 198    2  151-11809A                          Bus A Phase            GE                D24-Bus-09                          239                        Cap>Dem Relay    Support                                    802A-S                    gear Enclosure                  Test Overcurrent Relay Systems AC/DC A118 Breaker 809 Protective  Power                                    121AC53A                Switch  Control                Qualification 199    2  1Sl-11809B                          Bus B Phase            GE                D24-Bus-09                          239                        Cap> Dem Relay    Support                                    802A-S                    gear Enclosure                  Test Overcurrent Relay Systems AC/DC All8 Breaker 809 Protective  Power                                    121AC53A                Switch  Control                Qualification 200    2  151-11809C                          Bus C Phase            GE                D24-Bus-09                          239                        Cap> Dem Relay    Support                                    802A-S                    gear Enclosure                  Test Overcurrent Relay Systems AC/DC All5 Breaker 502 151N-        Protective  Power                                    121AC51A                Switch  Control                Qualification 201    1                                        Neutral Overcurrent    GE                Dll-Bus-02                          239                        Cap> Dem 11502          Relay    Support                                    801A-S                  gear  Enclosure                  Test Relay Systems Page 63 of 110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
            - -**                        Component                  *-
                                                                              -            Enclosure                                  Component Evaluation 11                                                                            Building      Floor j No. [ Unit                                                                                                              Elev. {ft) ,
Basis1for        Evaluation ID    :Type    I  System  I Function            Manufacturer Model No.      ID          Type
___j
                    ~
Capacity          Result AC/DC AllS Breaker S09 lSlN-  Protective    Power                                    121ACS1A                Switch  Control                  Qualification 202    1                                  Neutral Overcurrent    GE                Dll-Bus-09                            239                        Cap> Dem 11S09    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC A116 Breaker 602 lSlN-  Protective    Power                                    121AC51A                Switch  Control                  Qualification 203    1                                  Neutral Overcurrent    GE                D12-Bus-02                            239                        Cap>Dem 11602    Relay      Support                                      801A-S                  gear Enclosure                    Test Relay Systems AC/DC A116 Breaker 609 1S1N-  Protective    Power                                    121ACS1A                Switch  Control                  Qualification 204    1                                  Neutral Overcurrent    GE                D12-Bus-09                            239                        Cap> Dem 11609    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC All 7 Breaker 702 1S1N-  Protective    Power                                    121AC51A                Switch  Control                  Qualification 20S    1                                  Neutral Overcurrent    GE                D13-Bus-02                            239                        Cap> Dem 11702    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC All 7 Breaker 709 1S1N-  Protective    Power                                    121AC51A                Switch  Control                  Qualification 206    1                                  Neutral Overcurrent    GE                D13-Bus-09                            239                        Cap >Dem 11709    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC A118 Breaker 802 1S1N-  Protective    Power                                    121AC51A                Switch  Control                  Qualification 207    1                                  Neutral Overcurrent    GE                D14-Bus-02                            239                        Cap> Dem 11802    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC A118 Breaker 809 1S1N-  Protective    Power                                    121AC51A                Switch  Control                  Qualification 208    1                                  Neutral Overcurrent    GE                D14-Bus-09                            239                        Cap > Dem 11809    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC AllS Breaker S02 lSlN-  Protective    Power                                    121AC51A                Switch  Control                  Qualification 209    2                                  Neutral Overcurrent    GE                D21-Bus-02                          239                          Cap> Dem 11S02    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC AllS Breaker S09 lSlN-  Protective    Power                                    121ACS1A                Switch  Control                  Qualification 210    2                                  Neutral Overcurrent    GE                D21-Bus-09                          239                          Cap> Dem 11S09    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems AC/DC A116 Breaker 602 1S1N-  Protective    Power                                    121ACS1A                Switch  Control                  Qualification 211    2                                  Neutral Overcurrent    GE                D22-Bus-02                          239                          Cap> Dem 11602    Relay      Support                                    801A-S                    gear Enclosure                    Test Relay Systems Page 64 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                          Enclosure                              Component Evaluation No. Unit                                                  -                                                Building Floor Basis for        Evaluation I    ID    Type      System  Function            Manufacturer  Model1No.      ID          Type            Elev. (ft)
I                                              -                                                                              capacity__        Result AC/DC A116 Breaker 609 151N-  Protective  Power                                    121AC51A                Switch  Control              Quahficat1on 212    2                                  Neutral Overcurrent      GE                D22-Bus-09                          239                        Cap> Dem 11609    Relay    Support                                    801A-S                    gear Enclosure                Test Relay Systems AC/DC All 7 Breaker 702 151N-  Protective  Power                                    121AC51A                Switch  Control              Qualification 213    2                                  Neutral Overcurrent      GE                D23-Bus-02                          239                        Cap> Dem 11702    Relay    Support                                    801A-S                    gear Enclosure                Test Relay Systems AC/DC All 7 Breaker 709 151N-  Protective  Power                                    121AC51A                Switch  Control              Qualification 214    2                                  Neutral Overcurrent      GE                D23-Bus-09                          239                        Cap> Dem 11709    Relay    Support                                    801A-S                    gear Enclosure                Test Relay Systems AC/DC A118 Breaker 802 151N-  Protective  Power                                    121AC51A                Switch  Control              Qualification 215    2                                  Neutral Overcurrent      GE                D24-Bus-02                        239                        Cap> Dem 11802    Relay    Support                                    801A-S                    gear Enclosure                Test Relay Systems AC/DC A118 Breaker 809 151N-  Protective  Power                                    121AC51A                Switch  Control              Qualification 216    2                                  Neutral Overcurrent      GE                D24-Bus-09                        239                        Cap> Dem 11809    Relay    Support                                    801A-S                    gear Enclosure                Test Relay Systems AC/DC Control    Power  A115 Bus Lockout                                            Switch  Control              Qualification 217    1    186-115A                                        Electroswitch Series 24 Dll-Bus-06                        239                        Cap> Dem Relay    Support Relay                                                        gear Enclosure                Test Systems AC/DC Control    Power  A115 Bus Lockout                                            Switch  Control              Qualification 218    1    186-115B                                        Electroswitch Series 24 Dll-Bus-09                        239                        Cap> Dem Relay    Support Relay                                                        gear Enclosure                Test Systems AC/DC Control    Power  Al15 Bus Lockout                                            Switch  Control              Qualification 219    1    186-llSC                                        Electroswitch Series 24 Dll-Bus-09                        239                        Cap> Dem Relay    Support Relay                                                        gear Enclosure                Test Systems AC/DC Control    Power  Al16 Bus Lockout                                            Switch  Control              Qualification 220    1    186-116A                                        Electroswitch Series 24 D12-Bus-06                        239                        Cap> Dem Relay    Support Relay                                                        gear Enclosure                Test Systems AC/DC Control    Power  A116 Bus Lockout                                            Switch  Control              Qualification 221    1    186-116B                                        Electroswitch Series 24 D12-Bus-09                        239                        Cap> Dem Relay    Support Relay                                                        gear Enclosure                Test Systems Page 65 of 11 O
 
15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation j
BI                    -          Component                            -          --      Enclosure                                  Component Evaluation c                                                                                        Floor No.
        ~ ~.~ ~!  T~      J~vste-"'.J  Function          ; f1Manufacture~ 'I Model No.        ID          Type t  uildlng]  Elev. (ft)  B~sis  for caoacJty, Evaluation Result AC/DC Control    Power      All6 Bus Lockout                                                Switch    Control                Qualification 222  1  186-116C                                              Electroswitch    Series 24  D12-Bus-09                            239                        Cap> Dem Relay    Support    Relay                                                              gear  Enclosure                  Test Systems AC/DC Control    Power      All 7 Bus Lockout                                                Switch    Control                Qualification 223  1  186-117A                                              Electroswitch    Series 24  D13-Bus-06                            239                        Cap>Dem Relay    Support    Relay                                                              gear  Enclosure                  Test Systems AC/DC Control    Power      All 7 Bus Lockout                                                Switch    Control                Qualification 224  1  186-117B                                              Electroswitch    Series 24  D13-Bus-09                            239                        Cap> Dem Relay    Support    Relay                                                              gear  Enclosure                  Test Systems AC/DC Control    Power      All 7 Bus Lockout                                                Switch    Control              Qualification 225  1  186-117C                                              Electroswitch    Series 24  D13-Bus-09                            239                        Cap> Dem Relay    Support      Relay                                                              gear  Enclosure                  Test Systems AC/DC Cont rol    Power      All 8 Bus Lockout                                                Switch    Control              Qualification 226  1  186-118A                                              Electroswitch    Series 24  D14-Bus-06                            239                        Cap> Dem Relay    Support      Relay                                                              gear  Enclosure                  Test Systems AC/DC Control    Power      All8 Bus Lockout                                                Switch    Control              Qualification 227  1  186-118B                                              Electrosw itch  Series 24  D14-Bus-09                            239                        Cap> Dem Relay    Support      Relay                                                              gear  Enclosure                  Test Systems AC/DC Cont rol    Power      A118 Bus Lockout                                                Switch    Control              Qualification 228  1  186-118C                                              Electroswitch    Series 24  D14-Bus-09                            239                        Cap> Dem Relay    Support      Relay                                                              gear  Enclosure                  Test Systems AC/DC Control    Power                                                                      Switch    Control              Qualification 229  1 186-AGSOl                        Dll Lockout Relay    Electroswitch    Series 24  Dll-Bus-07                            239                        Cap> Dem Relay    Support                                                                        gear  Enclosure                  Test Systems AC/DC Control    Power                                                                      Switch    Control              Qualification 230  1 186-BGSOl                        D12 Lockout Relay    Electroswitch    Series 24  D12-Bus-07                            239                        Cap > Dem Relay    Support                                                                        gear  Enclosure                  Test Systems AC/DC Cont rol    Power                                                                      Switch    Control              Qualification 231  1 186-CGSOl                        D13 Lockout Relay    Electroswitch    Series 24  Dl3-Bus-07                            239                        Cap> Dem Relay    Support                                                                        gear  Enclosure                  Test Systems Page 66 of 110
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                          Enclosure                                ~Component Evaluation No. I <Unit r    ID T.'(111!  System    Function          I' Manufacturer  Model No. ID          Type Building Floor Elev. (ft) [
Basis 1for      Evaluation I                Capadtv            Result AC/DC Control    Power                                                                Switch  Control                Qualification 232    1    186-DGSOl                      D14 Lockout Relay    Electroswitch Series 24 D14-Bus-07                          239                          Cap> Dem Relay    Support                                                                gear Enclosure                    Test Systems AC/DC Control    Power    A115 Bus Lockout                                            Switch  Control                Qualification 233    2      186-llSA                                          Electroswitch Series 24 D21-Bus-06                          239                          Cap>Dem Relay    Support    Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    A115 Bus Lockout                                            Switch  Control                Qualification 234    2      186-llSB                                          Electroswitch Series 24 D21-Bus-09                          239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    A115 Bus Lockout                                            Switch  Control                Qualification 235    2      186-115C                                          Electroswitch Series 24 D21-Bus-09                        239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    A116 Bus Lockout                                            Switch  Control                Qualification 236    2      186-116A                                          Electroswitch Series 24 D22-Bus-06                        239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    A116 Bus Lockout                                            Switch  Control                Qualification 237    2      186-116B                                          Electroswitch Series 24 D22-Bus-09                        239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    A116 Bus Lockout                                            Switch  Control                Qualification 238    2      186-116C                                          Electroswitch Series 24 D22-Bus-09                        239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    All 7 Bus Lockout                                          Switch  Control                Qua Jification 239    2      186-117A                                          Electroswitch Series 24 D23-Bus-06                        239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    A117 Bus Lockout                                            Switch  Control                Qualification 240    2      186-117B                                          Electroswitch Series 24 D23-Bus-09                        239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                    Test Systems AC/DC Control    Power    All 7 Bus Lockout                                          Switch  Control                Qualification 241    2    186-117C                                            Electroswitch Series 24 D23-Bus-09                        239                          Cap> Dem Relay    Support  Relay                                                        gear Enclosure                  Test Systems Page 67of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation c
El                                                                                                  ~ ~ Bul~dln8]
Component                                              Enclosure  *  '* J                          Col!lponent Evaluation Floor No.
[~  ID JI Type    ff svste;J~ction      K 11 Manufacturer ! Model1No.      ID                                Elev. {ft)
Basis for Cai>acltv Evaluation Result AC/DC Control      Power  A118 Bus Lockout                                              Switch      Control                Qualification 242  2  186-118A                                                Electroswitch  Series 24  D24-Bus-06                              239                        Cap> Dem Relay      Support  Relay                                                          gear      Enclosure                  Test Systems AC/DC Control      Power  A118 Bus Lockout                                              Switch      Control                Qualification 243  2  186-llBB                                                Electroswitch  Series 24  D24-Bus-09                              239                        Cap> Dem Relay      Support  Relay                                                          gear      Enclosure                  Test Systems AC/DC Control      Power  A118 Bus Lockout                                              Switch      Control                Qualification 244  2  186-118C                                                Electroswitch  Series 24  D24-Bus-09                              239                        Cap> Dem Relay      Support  Relay                                                          gear      Enclosure                  Test Systems AC/DC Control      Power                                                                Switch      Control                Qualification 245  2  186-AGSOl                          D21 Lockout Relay    Electroswitch  Series 24  D21-Bus-07                              239                        Cap> Dem Relay      Support                                                                  gear      Enclosure                  Test Systems AC/DC Control      Power                                                                  Switch      Control              Qualification 246  2  186-BGSOl                          D22 Lockout Relay    Electroswitch  Series 24  D22-Bus-07                              239                        Cap> Dem Relay      Support                                                                  gear      Enclosure                  Test Systems AC/DC Control      Power                                                                  Switch      Control              Qualification 247  2  186-CGSOl                          D23 Lockout Relay    Electroswitch  Series 24 D23-Bus-07                              239                        Cap>Dem Relay      Support                                                                  gear      Enclosure                  Test Systems AC/DC Control      Power                                                                  Switch      Control              Qualification 248  2  186-DGSOl                          D24 Lockout Relay    Electroswitch  Series 24 D24-Bus-07                              239                        Cap> Dem Relay      Support                                                                  gear      Enclosure                  Test Systems AC/DC 150G-      Protective    Power  Dl14 Load Center                    12HFC11B                  Switch      Control              Qualification 249  1                                                                GE                  Dll-Bus-05                              239                        Cap> Dem 11505        Relay      Support  Ground Fault                            lA-S                    gear      Enclosu re                Test Systems AC/DC 150G-      Protective    Pow er  ESW Pump OAP548                      12HFC11B                  Switch      Control              Qualification 250  1                                                                GE                  Dll-Bus-08                              239                        Cap> Dem 11508        Relay      Support  Ground Fault                            lA-S                    gear      Enclosure                  Test Systems AC/DC 150G-      Protective    Power  D124 Load Center                    12HFC11B                  Switch      Control              Qualification 251 1                                                                GE                  D12-Bus-05                              239                        Cap> Dem 11605        Relay      Support  Ground Fault                            lA-S                    gear      Enclosure                  Test Systems Page 68 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS 177 Table B-1: Components Identified for High Frequency Confirmation
    'EJ l ~ L:ry~ ~I No. ; Unit :
1                System Component IFunction~* -:J lMan~~cturer j  Model No.      ID Enclosure Type r~ullding]    Floor Elev. {ft)
Component Evaluation Basis for, Capacltv Evaluation Result AC/DC 150G-  Protective  Power    ESW Pump OBP548                12HFC11B                Switch  Control                Qualification 252    1                                                            GE              D12-Bus-08                            239                          Cap> Dem 11608    Relay    Support    Ground Fault                      lA-S                    gear  Enclosure                    Test Systems AC/DC 150G-  Protective  Power    Dl34 Load Center                12HFC11B                Switch  Control                Qualification 253    1                                                            GE              D13-Bus-05                            239                          Cap> Dem 11705    Relay    Support    Ground Fault                        lA                    gear  Enclosure                    Test Systems AC/DC 150G-  Protective  Power    D144 Load Center                12HFC11B                Switch  Control                Qualification 254    1                                                            GE              D14-Bus-05                            239                          Cap> Dem 11805    Relay    Support    Ground Fault                      lA-S                    gear  Enclosu re                  Test Systems AC/DC 151N-  Protective  Power    Dll Neutral        Westinghous 264C899A                Switch  Control                Qualification 255    1                                                                              Dll-Bus-07                            239                          Cap> Dem AG501    Relay    Support    Overcurrent Relay        e        01                    gear  Enclosure                    Test Systems AC/DC 151N-  Protective  Power    D12 Neutral        westinghous 264C899A                Switch  Control                Qualification 256    1                                                                              D12-Bus-07                          239                          Cap> Dem BGSOl    Relay    Support    Overcurrent Relay        e        01                    gear  Enclosu re                  Test Systems AC/DC lSlN-  Protective  Power    D13 Neutral        Westinghous 264C899A                Switch  Control                Qualification 257    1                                                                              D13-Bus-07                          239                          Cap> Dem CGSOl    Relay    Support    Overcurrent Relay        e        01                    gear  Enclosure                    Test Systems AC/f?C 151N-  Protective  Power    D14 Neutral        Westinghous 264C899A                Switch  Control                Qualification 258    1                                                                              D14-Bus-07                          239                          Cap>Dem DG501    Relay    Support    Overcurrent Relay        e          01                    gear  Enclosure                  Test Systems AC/DC Protective  Power    AllS Bus A Phase                12PVD21B                Switch  Control                Qualification 259    1    187-llSA                                              GE                Dll-Bus-06                          239                          Cap> Dem Relay    Support    Differentia I Relay                lA-S                    gear  Enclosure                  Test Systems AC/DC Protective  Power    Al15 Bus B Phase                12PVD21B                Switch  Control                Qualification 260    1    187-1158                                              GE                Dll-Bus-06                          239                          Cap> Dem Relay    Support    Differential Relay                lA-S                    gear  Enclosure                  Test Systems AC/DC Protective  Power    AllS Bus C Phase                12PVD21B                Switch  Control                Qualification 261    1    187-llSC                                              GE                Dll-Bus-06                          239                          Cap> Dem Relay    Support    Differential Relay                lA-S                    gear  Enclosure                  Test Systems Page 69 of 110
 
15(4345-RPT-002, Rev. a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I      *EnclOsure ----=i Un~I                                                                                                            Bulldl~
Component                                                                                          f omponent Evaluation JI Floor I
,No. j t
[    110 _J[    Type      System] ~ction-            J; Manufacturer Model No.        ID
[~J                  Elev. (ft) 1 Basis for Caoacltv Evaluation Result AC/DC Protective  Power    A116 Bus A Phase                  12PVD21B                  Switch    Control                Qualification 262      1    187-116A                                                  GE                  D12-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power    A116 Bus B Phase                  12PVD21B                  Switch    Control                Qualification 263      1    187-116B                                                  GE                  D12-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power  A116 Bus C Phase                    12PVD21B                  Switch    Control                Qualification 264      1    187-116C                                                  GE                  D12-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power  All 7 Bus A Phase                  12PVD21B                  Switch    Control                Qualification 265      1    187-117A                                                  GE                  Dl3-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power  All 7 Bus B Phase                  12PVD21B                  Switch    Control                Qualification 266      1    187-117B                                                  GE                  D13-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power  All 7 Bus C Phase                  12PVD21B                  Switch    Control                Qualification 267      1    187-117C                                                  GE                  Dl3-Bus-06                          239                          Cap > Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power  Al18 Bus A Phase                    12PVD21B                  Switch    Control                Qualification 268      1    187-118A                                                  GE                  D14-Bus-06                          239                          Cap>Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power  A118 Bus B Phase                    12PVD21B                  Switch    Control                Qualification 269      1    187-llSB                                                  GE                  D14-Bus-06                          239                          Cap> Dem Relay    Support  Differential Relay                    lA-S                    gear    Enclosure                  Test Systems AC/DC Protective  Power  A118 Bus C Phase                    12PVD21B                  Switch    Control                Qualification 270      1    187-llSC                                                  GE                  D14-Bus-06                          239                          Cap > Dem Relay    Support  Differential Relay                    lA-5                      gear    Enclosure                  Test Systems AC/DC 150G-    Protective  Power  D214 Load Center                    12HFC11B                  Switch    Control                Qualification 271      2                                                                GE                  D21-Bus-OS                          239                          Cap> Dem 11505      Relay    Support  Ground Fault                          lA-S                      gear    Enclosure                  Test Systems Page 70of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
                                                                                      ~
Eli Component                                          Enclosyre                :
Component Evalu;itlon Floor No.
ID
                ]~-- ;vpe J  ISys~~] l!unctlo:~          "] [Manufa~~er ] Model No. ID M        Building Elev. (ft)  Basis for Capacity Evaluation Result AC/DC 150G-    Protective  Power  D224 Load Center                  12HFC11B                Switch  Control                Qualification 272  2                                                            GE                D22-Bus-05                        239                        Cap> Dem 11605        Relay    Support  Ground Fault                          lA-S                  gear Enclosure                  Test Systems AC/DC 150G-      Protective  Power  D234 Load Center                  12HFC11B                Switch  Control                Qualification 273  2                                                            GE                D23-Bus-DS                        239                        Cap > Dem 11705        Relay    Support Ground Fault                          lA-S                  gear Enclosure                  Test Systems AC/DC 150G-      Protective  Power  ESW Pump OCPS48                    12HFC11B                Switch  Control                Qualification 274  2                                                            GE                D23-Bus-08                        239                        Cap> Dem 11708        Relay    Support Ground Fault                          lA-S                  gear Enclosure                  Test Systems AC/DC 150G-      Protective  Power  D244 Load Center                  12HFC11B                Switch  Control                Qualification 275  2                                                            GE                D24-Bus-DS                        239                        Cap> Dem 11805        Relay    Support Ground Fault                          1A-S                  gear Enclosure                  Test Systems AC/DC 150G-      Protective  Power  ESW Pump DDPS48                    12HFC11B                Switch  Control              Qualification 276  2                                                            GE                D24-Bus-08                        239                        Cap> Dem 11808        Relay    Support Ground Fault                          1A-S                  gear Enclosure                  Test Systems AC/DC 151N-      Protective  Power  D21 Neutral            Westinghous  264C899A                Switch  Control              Qualification 277  2                                                                              D21-Bus-07                        239                        Cap> Dem AG501        Relay    Support Overcurrent Relay            e          01                    gear Enclosure                  Test Systems AC/DC 151N-      Protective  Power  D22 Neutral            Westinghous  264C899A                Switch  Control              Qualification 278  2                                                                              D22-Bus-07                        239                        Cap>Dem BG501        Relay    Support Overcurrent Relay            e          01                    gear Enclosure                  Test Systems AC/DC 151N-      Protective  Power  D23 Neutral            westinghous  264C899A                Switch  Control              Qualification 279  2                                                                              D23-Bus-07                        239                        Cap> Dem CGSOl        Relay    Support Overcurrent Relay          e          01                    gear Enclosure                  Test Systems AC/DC 151N-      Protective  Power  D24 Neutral            Westinghous  264C899A                Switch  Control              Qualification 280  2                                                                              D24-Bus-07                        239                        Cap> Dem DGS01        Relay    Support Overcurrent Relay          e          01                    gear Enclosure                  Test Systems AC/DC Protective  Power  AUS Bus A Phase                    12PVD21B                Switch  Control              Qualification 281  2 187-llSA                                                  GE                D21-Bus-06                        239                        Cap> Dem Relay    Support Differential Relay                    lA-S                    gear Enclosure                  Test Systems Page 71 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I      I Component                                        Enclosure                  I                Component Evaluation Floor No. Unit                                                                                                        Building                !Iasis for      Evaluation ID    II  Type    System  Function          Manufacturer Model No. ID          Type '              Elev. (ft)
Capacltv          Result
            ~
AC/DC Protective  Power  AUS Bus B Phase                12PVD21B                Switch    Control                Qualification 282    2      187-llSB                                                GE                D21-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                lA-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  AUS Bus C Phase                12PVD21B                Switch    Control                Qualification 283    2      187-USC                                                GE                D21-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                lA-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  AU6 Bus A Phase                12PVD21B                Switch    Control                Qualification 284    2      187-U6A                                                GE                D22-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                lA-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  A116 Bus B Phase                12PVD21B                Switch    Control                Qualification 285    2      187-116B                                                GE                D22-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                lA-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  Al16 Bus C Phase                12PVD21B                Switch    Control                Qualification 286    2      187-116C                                                GE                D22-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                lA-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  All 7 Bus A Phase                12PVD21B                Switch    Control                Qualification 287    2      187-117A                                                GE                D23-Bus-06                            239                        Cap> Dem Relay    Support  Differential Relay                lA-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  A117 Bus B Phase                12PVD21B                Switch    Control                Qualification 288    2      187 -117B                                              GE                D23-Bus-06                            239                        Cap> Dem Relay    Support Differential Relay                  1A-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  AU 7 Bus C Phase                12PVD21B                Switch    Control                Qualification 289    2      187-117C                                                GE                D23-Bus-06                            239                        Cap> Dem Relay    Support Differential Relay                  1A-S                  gear  Enclosure                    Test Systems AC/DC Protective  Power  A118 Bus A Phase                12PVD21B                Switch    Control                Qualification 290    2      187-118A                                                GE                D24-Bus-06                            239                        Cap> Dem Relay    Support Differential Relay                1A-S                    gear  Enclosure                    Test Systems AC/DC Protective  Power  A118 Bus B Phase                12PVD21B                Switch    Control                Qualification 291    2      187-118B                                                GE                D24-Bus-06                            239                        Cap> Dem Relay    Support Differential Relay                1A-S                    gear  Enclosure                    Test Systems Page 72 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 8-1: Components Identified for High Frequency Confirmation Component                                          IEnclosure                                  Component Evaluation
                                                                                                          ~ I Building J Elev.
Floor
                ,(~~'] [_          ] rs;~ [ ~unction        _=1 [ ~anufa~~rer 1I M~eiNo. 1      ID                                      '
No. :'8  1                                                                                                                          (ft)
Basis ,for      Evaluation f ype Capacitv            Result AC/DC Protective    Power  A118 Bus C Phase                    12PVD21B                Switch  Control                Qualification 292    2    187-118C                                                  GE                  D24-Bus-06                          239                          Cap> Dem Relay      Support  Differential Relay                    l A-S                  gear  Enclosure                  Test Systems Medium        AC/DC Dll-Bus-07    Voltage      Power  Dll Diesel Generator                                        Switch  Control                Qualification 293    1                                                            ABB/ITE      5HK 350  D11-Bus-07                          239                        Cap> Dem (152-11507)    Ci rcuit    Support Circuit Breaker                                                gear  Enclosure                  Test Breaker    Systems Medium        AC/DC Dll-Bus-05    Voltage      Power  D114 LC Transformer                                        Switch  Control                Qualification 294    1                                                            ABB/ITE      5HK 350  D11-Bus-05                          239                          Cap> Dem
{152-11505)    Circuit    Support Circu it Breaker                                              gear  Enclosure                  Test Breaker    Systems Medium      AC/DC QA Essential Service D11-Bus-08    Voltage      Pow er                                                              Sw itch  Control                Qualification 295    1                                      Water Pump Circuit    ABB/ITE      5HK 350  Dll-Bus-08                          239                          Cap> Dem
{152-11508)    Circuit    Support                                                                gear  Enclosure                  Test Breaker Breaker    Systems Medium      AC/DC D12-Bus-07    Voltage      Power  D12 Diesel Generator                                        Switch  Control                Qualification 296    1                                                            ABB/ITE      5HK 350  D12-Bus-07                          239                          Cap > Dem
{152-11607)    Ci rcuit  Support  Circuit Breaker                                                gear  Enclosure                  Test Breaker    Sy stems Medium      AC/DC D12-Bus-05    Voltage      Power  D124 LC Transformer                                          Sw itch  Control                Qualification 297    1                                                            ABB/ITE      5HK 350  012-Bus-05                          239                          Cap> Dem (152-11605)    Circuit    Support  Ci rcuit Breaker                                              gear  Enclosure                  Test Breaker    Systems Medium      AC/DC OB Essential Service D12-Bus-08    Voltage      Power                                                                Sw itch  Control                Qualification 298    1                                      Water Pump Circuit    ABB/ITE      5HK 350  D12-Bus-08                          239                          Cap> Dem (152-11608)    Circuit    Support                                                                gear  Enclosure                  Test Breaker Breaker    Systems Medium      AC/DC D13-Bus-07    Voltage      Power  Dl3 Diesel Generator                                        Switch  Control                Qualification 299    1                                                            ABB/ITE      5HK 350  013-Bus-07                          239                          Cap > Dem (152-11707)    Circuit    Support  Circuit Breaker                                                gear  Enclosure                  Test Breaker    Systems Page 73 of 110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                          Enclosure                              Component Evaluation Floor No. Unit                                                                                                    Building              Basis for        Evaluation ID      Type    System  Function            'Manufacturer Model1No. ID          Type            Elev. (ft) i                                                                                                                          caoacltv            Result Medium    AC/DC DB-Bus-OS  Voltage  Power  OB4 LC Transformer                                        Switch  Control              Qualification 300  1                                                            ABB/ITE    5HK 350  DB-Bus-OS                          239                        Cap> Dem (152-11705)  Circuit Support  Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Medium    AC/DC D14-Bus-07  Voltage  Power  D14 Diesel Generator                                      Switch  Control              Qualification 301  1                                                            ABB/ITE    SHK 350  D14-Bus-07                        239                        Cap> Dem (152-11807)  Circuit Support  Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Medium    AC/DC D14-Bus-05  Voltage  Power  D144 LC Transformer                                        Switch  Control              Qualification 302  1                                                            ABB/ITE    SHK 350  D14-Bus-OS                        239                        Cap> Dem (152-11805)  Circuit Support Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Medium    AC/DC D21-Bus-07  Voltage  Power  D21 Diesel Generator                                        Switch  Control              Qualification 303  2                                                            ABB/ITE    SHK 350  D21 Bus-07                        239                        Cap> Dem (152-11507)  Circuit Support Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Medium    AC/DC D21-Bus-OS  Voltage  Power  D214 LC Transformer                                        Switch  Control              Qualification 304  2                                                            ABB/ITE    SHK 350  D21-Bus-OS                        239                        Cap> Dem (152-11505)  Circuit Support Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Medium    AC/DC D22-Bus-07  Voltage  Power  D22 Diesel Generator                                        Switch  Control              Qualification 305  2                                                            ABB/ITE    SHK 350  D22-Bus-07                        239                        Cap> Dem (152- 11607)  Circuit Support Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Medium    AC/DC D22-Bus-OS  Voltage  Power  D224 LC Transformer                                        Switch  Control              Qualification 306  2                                                            ABB/ITE    SHK 350  D22-Bus-OS                        239                        Cap> Dem (152-11605)  Circuit Support Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Medium    AC/DC D23-Bus-07  Voltage  Power  D23 Diesel Generator                                        Switch  Control              Qualification 307  2                                                            ABB/ITE    SHK 350  D23-Bus-07                        239                        Cap> Dem
{152-11707)  Circuit  Support Circuit Breaker                                              gear Enclosure                Test Breaker  Systems Page 74of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I                ---              ~mponent                                            Enclosure                                  Component Evaluation
            '~                                                                              -                                    Floor I No. 1 Unit* j"      ID      il'ype I
System  ~ Function I
Manufacturer Model No. ID          Type Building
                                                                                                                              ' Elev. (ft) j Basis for        Evaluation
            ~    .    ~                                                                                                      L  -          Capacity          Result Medium      AC/DC D23-Bus-05 Voltage    Power    D234 LC Transformer                                        Switch  Control                  Qualification 308    2                                                                ABB/ITE    5HK 350  D23-Bus-05                            239                        Cap> Dem (152-11705)  Circuit  Support  Circuit Breaker                                              gear  Enclosure                    Test Breaker    Systems Medium      AC/DC OC Essential Service D23-Bus-08 Voltage    Power                                                              Switch  Control                  Qualification 309    2                                        Water Pump Circuit      ABB/ITE    5HK 350  D23-Bus-08                            239                        Cap> Dem (152-11708)  Circuit  Support                                                                gear  Enclosure                    Test Breaker Breaker    Systems Medium      AC/DC D24-Bus-07  Voltage    Power    D24 Diesel Generator                                      Switch  Control                  Qualification 310    2                                                                ABB/ITE    5HK 350  D24-Bus-07                            239                        Cap> Dem (1S2-11807)  Circuit  Support  Circuit Breaker                                              gear  Enclosure                    Test Breaker    Systems Medium      AC/DC D24-Bus-05  Voltage    Power    D244 LC Transformer                                        Switch  Control                  Qualification 311    2                                                                ABB/ITE    5HK 350  D24-Bus-05                            239                        Cap> Dem (152-11805) Circuit    Support  Circuit Breaker                                              gear  Enclosure                    Test Breaker    Systems Medium      AC/DC OD Essential Service D24-Bus-08  Voltage    Power                                                              Switch  Control                  Qualification 312    2                                        Water Pump Circuit      ABB/ITE    5HK 350  D24-Bus-08                            239                        Cap> Dem (152-11808) Circuit    Support                                                                gear  Enclosure                    Test Breaker Breaker    Systems AC/DC T2A (1ETB- Control    Power                                      ETR14D3B    1ETB-      Control  Diesel                  Qualification 313    1                                        Overcrank Relay          Tyco                                                    217                          Cap> Dem AG501)    Relays    Support                                        004      AG501        Cab. Generator                    Test Systems AC/DC T2B (1ETB- Control    Power                                      ETR14D3B    1ETB-      Control  Diesel                  Qualification 314    1                                        Overcrank Relay          Tyco                                                    217                          Cap> Dem AG501)    Relays    Support                                        004      AG501        Cab. Generator                    Test Systems AC/DC T2A (1ETB- Control    Power                                      ETR14D3B    1ETB-      Control  Diesel                  Qualification 315    1                                        Overcrank Relay          Tyco                                                    217                          Cap> Dem BG501)  Relays    Support                                        004      BG501        Cab. Generator                    Test Systems AC/DC T2B (lETB- Control    Power                                      ETR14D3B    lETB-      Control  Diesel                  Qualification 316    1                                        Overcrank Relay          Tyco                                                    217                          Cap> Dem BG501)    Relays    Support                                        004      BG501        Cab. Generator                    Test Systems Page 75 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
      ~    ~I                              Component                                    Enclosure I
Component Evaluation Floor No. I  Unit I ID      i:vpe  System  II Function        Manufacturer Model No. ID          Type Building Elev. (ft) I  Basis for Capacltv Evaluation Result AC/DC T2A (lETB- Control  Power                                  ETR14D3B  lETB-      Control  Diesel                Qualification 317    1                                    Overcrank Relay    Tyco                                                  217                        Cap > Dem CGSOl)    Relays Support                                    004    CGSOl          Cab. Generator                  Test Systems AC/DC T2B (lETB- Control  Power                                  ETR14D3B  lETB-      Control  Diesel                Qualification 318    1                                    Overcrank Relay    Tyco                                                  217                        Cap> Dem CGSOl)    Relays Support                                    004    CGSOl          Cab. Generator                  Test Systems AC/DC T2A (lETB- Control  Power                                  ETR14D3B  lETB-      Control  Diesel                Qualification 319    1                                    Overcrank Relay  Amerace                                                  217                        Cap> Dem DGSOl)    Relays Support                                    002    DGSOl          Cab. Generator                  Test Systems AC/DC T2B (lETB- Control  Power                                  ETR14D3B  lETB-      Control  Diesel                Qualification 320    1                                    Overcrank Relay  Amerace                                                  217                        Cap> Dem DGSOl)    Relays Support                                    002    DGSOl          Cab. Generator                  Test Systems AC/DC T2A (2ETB- Control  Power                                  ETR14D3B  2ETB-        Control  Diesel                Qualification 321    2                                    Overcrank Relay    Tyco                                                  217                        Cap> Dem AGSOl)  Relays  Support                                    004    AGSOl          Cab. Generator                  Test Systems AC/DC T2B (2ETB- Control  Power                                  ETR14D3B  2ETB        Control  Diesel                Qualification 322    2                                    Overcrank Relay    Tyco                                                  217                        Cap> Dem AGSOl)  Relays  Support                                    004    AGSOl          Cab. Generator                  Test Systems AC/DC T2A (2ETB- Control  Power                                  ETR14D3B  2ETB-        Control  Diesel                Qualification 323    2                                    Overcrank Relay    Tyco                                                  217                          Cap>Dem BGSOl)  Relays  Support                                    004    BGSOl          Cab. Generator                  Test Systems AC/DC T2B (2ETB- Control  Power                                  ETR14D3B  2ETB-        Control  Diesel                Qualification 324    2                                    Overcrank Relay    Tyco                                                  217                          Cap> Dem BGSOl)  Relays  Support                                    004    BGSOl          Cab. Generator                  Test Systems AC/DC T2A (2ETB- Control  Power                                  ETR14D3B  2ETB-        Control  Diesel                Qualification 325    2                                    Overcrank Relay    Tyco                                                  217                          Cap> Dem CGSOl)    Relays  Support                                  004    CGSOl          Cab. Generator                  Test Systems AC/DC T2B (2ETB- Control  Power                                  ETR14D3B  2ETB-        Control  Diesel                Qualification 326    2                                    Overcrank Relay    Tyco                                                  217                          Cap > Dem CGSOl)    Relays  Support                                  004    CGSOl          Cab. Generator                  Test Systems Page 76 of 110
 
1SC4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                      Enclosure                                Component Evaluation No. I'rIUnlt j    ID        Type  System
* l Function          Manufacturer Model No. ID          Type BulldJng Floor.-
Elev. {ft)
Basls*for      Evaluation
                          ~
                                                          -    1
                                                                                      -                                              capacity          Result AC/DC T2A (2ETB-  Control  Power                                    ETR14D3B  2ETB-      Control  Diesel              Qualification 327      2                                    Overcrank Relay      Amerace                                                217                      Cap> Dem DG501)      Relays Support                                      002    DGS01          Cab. Generator                Test Systems AC/DC T2B (2ETB-  Control  Power                                    ETR14D3B  2ETB-      Control  Diesel              Qualification 328      2                                    Overcrank Relay      Amerace                                                217                      Cap> Dem DG501)      Relays Support                                      002    DG501          Cab. Generator                Test Systems AC/DC T3A (1ETB-  Control  Power                                    ETR14D3B  lETB-      Control  Diesel              Qualification 329      1                                    High Speed Relay      Tyco                                                  217                      Cap> Dem AGSOl)      Relays Support                                      004    AGSOl          Cab. Generator                Test Systems AC/DC T3A (1ETB-  Control  Power                                    ETR14D3B  lETB-      Control  Diesel              Qualification 330      1                                    High Speed Relay      Tyco                                                  217                        Cap> Dem BGSOl)      Relays Support                                      004    BGSOl          Cab. Generator                Test Systems AC/DC T3A (lETB-  Control  Power                                    ETR14D3B  1ETB-        Control  Diesel              Qualification 331      1                                    High Speed Relay      Tyco                                                  217                        Cap> Dem CGSOl)    Relays  Support                                      004    CGSOl          Cab. Generator                Test Systems AC/DC T3A (lETB-  Control  Power                                    ETR14D3B  lETB-        Control  Diesel              Qualification 332      1                                    High Speed Relay    Amerace                                                217                        Cap> Dem DGSOl)      Relays Support                                      002    DGSOl          Cab. Generator                Test Systems AC/DC T3A (2ETB-  Control  Power                                    ETR14D3B  2ETB-        Control  Diesel              Qualification 333      2                                    High Speed Relay      Tyco                                                  217                        Cap> Dem AG501)      Relays  Support                                      004    AGSOl          Cab. Generator                Test Systems AC/DC T3A (2ETB-  Control  Power                                    ETR14D3B  2ETB-        Control  Diesel              Qualification 334      2                                    High Speed Relay      Tyco                                                  217                        Cap> Dem BG501)    Relays  Support                                      004    BGSOl          Cab. Generator                Test Systems AC/DC T3A (2ETB-  Control  Power                                    ETR14D3B  2ETB-        Control  Diesel              Qualification 335      2                                    High Speed Relay      Tyco                                                  217                        Cap> Dem CGSOl)      Relays  Support                                      004    CGSOl          Cab. Generator                Test Systems AC/DC T3A (2ETB-  Control  Power                                    ETR14D3B  2ETB-        Control  Diesel              Qualification 336      2                                    High Speed Relay    Amerace                                                217                        Cap >Dem DGSOl)      Relays  Support                                      002    DGSOl          Cab. Generator                Test Systems Page 77of110
 
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.
J Unit I  ~
Component
                                                          -              -            Enclosure Building I  Floor I Component Evaluation Basls*for    Evaluation I                                                                                                Elev. (ft)
* ID    Type  System  Function            Manufacturer Model No. ID          Type
                        -                                                                              -                          Capacity        Result AC/DC Control  Power  Emergency Stop                              lETB-      Control    Diesel 337    1      Dll-SE                                          Amerace    7024PE                                        217        GERS        Cap> Dem Relays Support  Relay                                      AGSOl          Cab. Generator Systems AC/DC Control  Power  Emergency Stop                              lETB-      Control    Diesel 338    1      D12-SE                                          Amerace    7024PE                                        217        GERS        Cap>Dem Relays Support  Relay                                      BGSOl          Cab. Generator Systems AC/DC Control  Power  Emergency Stop                              lETB-      Control    Diesel 339    1      D13-SE                                          Amerace    7024PE                                        217        GERS        Cap> Dem Relays Support  Relay                                      CGSOl          Cab. Generator Systems AC/DC Control  Power  Emergency Stop                              lETB-      Control    Diesel 340    1      D14-SE                                          Amerace    7024PE                                        217        GERS        Cap> Dem Relays  Support  Relay                                      DGSOl          Cab. Generator Systems AC/DC Control  Power  Emergency Stop                              2ETB-      Control    Diesel 341    2    D21-SE                                          Amerace      7024PE                                        217        GERS        Cap> Dem Relays  Support  Relay                                      AGSOl          Cab . Generator Systems AC/DC Control  Power  Emergency Stop                              2ETB-        Control    Diesel 342    2    D22-SE                                          Amerace    7024PE                                        217        GERS        Cap> Dem Relays  Support  Relay                                      BGSOl          Cab. Generator Systems AC/DC Control  Power  Emergency Stop                              2ETB-        Control    Diesel 343    2    D23-SE                                          Amerace      7024PE                                        217        GERS        Cap> Dem Relays  Support Relay                                      CGSOl          Cab. Generator Systems AC/DC Control  Power  Emergency Stop                              2ETB-        Control    Diesel 344    2    D24-SE                                          Amerace      7024PE                                        217        GERS        Cap> Dem Relays  Support Relay                                      DGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              lETB-        Control    Diesel 345    1    Dll-CPl                                            ITE      Jl3P3012                                      217        GERS        Cap> Dem Relays  Support Pressure Low Relay                          AGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              lETB-        Control    Diesel 346    1    Dll-CP2                                            ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support Pressure Low Relay                          AGSOl          Cab. Generator Systems Page 78of110
 
15C4345-RPT-002, Rev. 0 Correspondence No. : RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No * .
EJ[ -
ID J[  Type    ]'i  System AC/DC Component
                                          * ~nction        --=i Illll~~ufacturer Model No. ID Enclosure
                                                                                                        ~
:I  Buil~~ni] Flo;o J Elev.~)
Component Evaluation Basis for Capacity Evaluation Result Control      Power    Jacket Cooling                                    lETB-        Control      Diesel 347    1 D11-CP3                                                        ITE    J13P3012                                          217      GERS          Cap> Dem Relays      Support  Pressure Low Relay                              AGSOl            Cab. Generator Systems AC/DC Control      Power    Jacket Coolant                                  lETB-        Control      Diesel 348    1 Dll-CTl                                                        ITE    J13P3012                                          217      GERS          Cap> Dem Rela ys    Support  Temperature Relay                              AGSOl            Cab. Generator Systems AC/DC Control      Power    Jacket Coolant                                  lETB-        Control      Diesel 349    1 Dll-CT2                                                        ITE      J13P3012                                          217      GERS        Cap> Dem Relays      Support  Temperature Relay                              AG501            Cab. Generator Systems AC/DC Control      Power    Jacket Coolant                                  lETB-        Control      Diesel 350    1 D11-CT3                                                        ITE      J13P3012                                          217      GERS        Cap> Dem Relays      Support  Temperature Relay                              AG501            Cab. Generator Systems AC/DC Control      Power    Lube Oil Pressure                                lETB-        Control      Diesel 351    1 Dll-OPl                                                        ITE      J13P3012                                          217      GERS        Cap> Dem Relays      Support  Low Relay                                      AG501            Cab. Generator Systems AC/DC Control      Power    Lube Oil Pressure                                lETB-        Control      Diesel 352    1 Dll-OP2                                                        ITE      Jl3P3012                                          217      GERS        Cap> Dem Relays      Support  Low Relay                                      AG501            Cab. Generator Systems AC/DC Control      Power    Lube Oil Pressure                                lETB-        Control      Diesel 353    1 Dll-OP3                                                        ITE      J13P3012                                          217      GERS        Cap>Dem Rela ys      Support  Low Relay                                      AG501            Cab. Generator Systems AC/DC Control      Power    Lube Oil High                                  lETB-          Control      Diesel 354    1 Dll-OTl                                                        ITE      J13P3012                                          217      GERS        Cap> Dem Relays      Support  Temperature Relay                              AG501            Cab. Generator Systems AC/DC Cont rol      Power    Lube Oil High                                  lETB-          Control      Diesel 355    1 Dl1-0T2                                                      ITE      J13P3012                                          217      GERS        Cap> Dem Relays      Support  Temperature Relay                              AGSOl            Cab. Generato r Systems AC/DC Control      Pow er  Lube Oil High                                  lETB-          Control      Diesel 356    1 Dl1-0T3                                                      ITE      J13P3012                                          217      GERS        Cap> Dem Rela ys      Support  Temperature Relay                              AGSOl            Cab. Generator Systems Page 79 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. 'i EJ 1* ~~.J [ ~ J[~tem] ~ction Compone!lt
                                                      ,_] rM~ufact~rer II~od;!No.] rw. '_ IDEnclosure ~ ..
r T~]
I Building j iElev.
Floor  J (ft)
Component Evaluation Basis for caoacltv
                                                                                                                                                    ~ Evaluation Result AC/DC Control  Power                                                      lETB-      Control    Diesel 357    1    Dll-SDR                  Shutd own Relay          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support                                                    AG501          Cab . Generator Systems AC/DC Control  Power                                                      lETB-      Control    Diesel 358    1    Dll-SFR                  Start Failure Relay      ITE        J13P3012                                            217        GERS        Cap>Dem Relays Support                                                    AGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                                      lETB-      Control    Diesel 359    1    D12-CP1                                          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support  Pressure Low Relay                                BG501          Cab. Generator Systems AC/DC Control  Power  Jacket Cool ing                                    lETB-      Control    Diesel 360    1    D12-CP2                                          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support  Pressure Low Relay                                BG501          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                                      lETB-      Control    Diesel 361    1    D12-CP3                                          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support Pressure Low Relay                                BG501          Cab. Generator Systems AC/DC Control  Power  Jacke t Coolant                                    lETB-      Control    Diesel 362    1    D12-CT1                                          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support Temperature Relay                                  BGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                                      lETB-      Control    Diesel 363    1    D12-CT2                                          ITE        Jl3P3012                                            217        GERS        Cap> Dem Relays  Support Temperature Relay                                  BG501          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                                      lETB-      Control    Diesel 364    1    D12-CT3                                          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support Temperature Relay                                  BG501          Cab. Generator Systems AC/DC Control  Power  Lube Oil Pressure                                  lETB-      Control    Diesel 365    1    D12-0P1                                          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support Low Relay                                          BG501          Cab. Generator Systems AC/DC Control  Power  Lube Oil Pressure                                  lETB-        Control    Diesel 366    1    D12-0P2                                          ITE        J13P3012                                            217        GERS        Cap> Dem Relays  Support Low Relay                                          BG501          Cab. Generator Systems Page 80of110
 
15C4345-RPT-002, Rev. 0 Correspondence No. : RS- 16-177 Table B-1: Components Identified for High Frequency Confirmation B[
                ~
                                                                                                                  ~ Elev.
Floo~    '
Component                                                Enclosure                                  Component Evaluation No.
:*~]  Type
                      ~~ ~ction                  I              l
[ Manufacturer [ M:ciel No. j 1    ID 1-1        Building (ft)
Basis for CapacltV    '*
Evaluation Result AC/DC Control  Power  Lube Oil Pressure                                    lETB-      Control  Diesel 367 1 D12-0P3                                            ITE      J13P3012                                            217        GERS          Cap > Dem Relays Support  Low Relay                                          BGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                                        lETB-      Control  Diesel 368 1 D12-0Tl                                            ITE      J13P3012                                            217        GERS          Cap> Dem Relays Support Temperature Relay                                    BGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                                        lETB-      Control  Diesel 369 1 D12-0T2                                            ITE      J13P3012                                            217        GERS          Cap> Dem Relays Support Temperature Relay                                    BGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                                        lETB-      Control  Diesel 370 1 D12-0T3                                            ITE      J13P3012                                            217        GERS          Cap> Dem Relays Support Temperature Relay                                    BGSOl          Cab. Generator Systems AC/DC Control  Power                                                        lETB-      Control  Diesel 371 1 D12-SDR                Shutdown Relay            ITE        J13P3012                                            217        GERS          Cap> Dem Relays Support                                                      BGSOl          Cab. Generator Systems AC/DC Control  Power                                                      lETB-        Control  Diesel 372 1 D12-SFR                Start Failure Relay        ITE        J13P3012                                            217        GERS          Cap> Dem Relays  Support                                                      BGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                                      lETB-        Control  Diesel 373 1 D13-CP1                                            ITE        J13P3012                                            217        GERS          Cap> Dem Relays  Support Pressure Low Relay                                  CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                                      lETB-        Control  Diesel 374 1 D13-CP2                                            ITE        J13P3012                                          217        GERS          Cap> Dem Relays  Support Pressure Low Relay                                  CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                                      lETB-        Control  Diesel 375 1 D13-CP3                                            ITE        J13P3012                                          217        GERS          Cap > Dem Relays  Support Pressure Low Relay                                  CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                                      lETB-        Control  Diesel 376 1 D13-CT1                                            ITE        J13P3012                                          217        GERS          Cap> Dem Relays  Support Temperature Relay                                    CGSOl          Cab. Generator Systems Page 81 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. I 81    ,ID  II Ty~
Component
                          ] [Sv~i;m ~ ~ction      -*
JrManufacturer 1~No.
                                                                                    ~
                                                                                    !*    ID Enclosure
                                                                                                    ~
8Building  1 Floor Elev. (ft)
Component Evaluation Basis for Capacity Evaluation Result AC/DC Control    Power    Jacket Coolant                                    lETB-      Control  Diesel 377  1 D13-CT2                                                  ITE        J13P3012                                        217        GERS          Cap > Dern Relays    Support  Temperature Relay                                CGSOl          Cab. Generator Systems AC/DC Control    Power  Jacket Coolant                                    lETB-      Control  Diesel 378  1 D13-CT3                                                  ITE      J13P3012                                        217        GERS        Cap> Dern Relays    Support  Temperature Relay                                CGSOl          Cab. Generator Systems AC/DC Control    Power    Lube Oil Pressure                                lETB-      Control  Diesel 379  1 D13-0P1                                                  ITE      J13P3012                                        217        GERS        Cap> Dern Relays    Support  Low Relay                                        CGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil Pressure                                  lETB-      Control  Diesel 380  1 D13-0P2                                                  ITE      J13P3012                                        217        GERS        Cap > Dern Relays    Support  Low Relay                                        CGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil Pressure                                  lETB-      Control  Diesel 381  1 D13-0P3                                                  ITE      J13P3012                                        217        GERS        Cap> Dem Relays    Support  Low Relay                                        CGSDl          Cab. Generator Systems AC/DC Control    Power  Lube Oil High                                      lETB-      Control  Diesel 382  1 Dl3-0T1                                                  ITE      J13P3012                                        217        GE RS        Cap > Dern Relays    Support  Temperature Relay                                CGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil High                                    lETB-        Control  Diesel 383  1 Dl3-0T2                                                ITE        J13P3012                                        217        GERS        Cap > Dem Relays    Support  Temperature Relay                                CGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil High                                    lETB-        Control  Diesel 384  1 Dl3-0T3                                                ITE        J13P3012                                        217        GERS        Cap > De rn Relays    Support  Temperature Relay                                CGSOl          Cab. Generator Systems AC/DC Control    Power                                                    lETB-        Control  Diesel 385  1 Dl3-SDR                      Shutdown Relay            ITE        J13P3012                                        217        GERS        Cap> Dem Relays    Support                                                    CGSOl          Cab. Generator Systems AC/DC Control    Power                                                    lETB-        Control  Diesel 386  1 013-SFR                      Start Fai lure Relay      ITE        J13P3012                                        217        GERS        Cap> Dem Relays    Support                                                    CGSOl          Cab. Generator Systems Page 82of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
: r.                      I EJ                                                                                                        rB~~--1
                  -          -        Component                                          Enclosure                                    Component_;valuation Floor No.
[    10_    Jl _:rv~ J~ Syste~ ~ction ==:JI        Manufacturer Mo<!el1No.      10      [  Typ~                Elev. (ft)
Basls*for Capacltv1 Evaluation Result AC/DC Co ntrol  Power  Jacket Cooling                                  l ETB-      Control      Diesel 387  1  D14-CP1                                                ITE    J13P3012                                            217        GERS        Cap> Dem Rela ys Support  Pressure Low Relay                            DGSOl          Cab.      Generator Systems AC/DC Control  Power  Jacket Cooling                                  lETB-      Control      Diesel 388  1  D14-CP2                                              ITE      Jl3P3012                                            217        GERS        Cap> Dem Relays  Support  Pressure Low Relay                            DGSOl          Cab.      Generator Systems AC/DC Cont rol  Power  Jacket Cooling                                  lETB-      Control      Diesel 389  1  D14-CP3                                                ITE    J13P3012                                            217        GERS        Cap> Dem Relays  Support  Pressure Low Relay                            DGSOl          Cab.      Generator Systems AC/ DC Control  Power  Jacket Coolant                                  lETB-      Control      Diesel 390  1  D14-CT1                                                ITE    J13P3012                                            217        GERS        Cap> Dem Relays  Support Temperature Relay                              DGSOl          Cab.      Generator Systems AC/DC Control  Power  Jacket Coolant                                lETB-        Control      Diesel 391  1  D14* CT2                                              ITE      J13P3012                                            217        GERS        Cap> Dem Relays  Support Temperature Relay                              DGSOl          Cab.      Generator Systems AC/DC Control  Power  Jacket Coolant                                lETB-        Control      Diesel 392  1  D14-CT3                                              ITE      J13P3012                                            217        GERS        Cap> Dem Relays  Support Temperature Relay                              DGSOl          Cab.      Generator Systems AC/DC Control  Power  Lube Oil Pressure                              lETB-        Control      Diesel 393  1  D14-0P1                                              ITE      J13P3012.                                          217        GERS        Cap>Dem Relays  Support Low Relay                                      DGSOl          Cab.      Generator Systems AC/DC Control  Power  Lube Oil Pressure                              lETB-        Control      Diesel 394  1  D14-0P2                                              ITE      J13P3012                                            217        GERS        Cap> Dem Relays  Support Low Relay                                      DGSOl          Cab.      Generator Systems AC/DC Control  Power  Lube Oil Pressure                              lETB-        Control      Diesel 395  1  D14-0P3                                              ITE      J13P3012                                            217        GERS        Cap> Dem Relays  Support Low Relay                                      DGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                                  lETB-        Cont rol    Diesel 396  1  D14-0T1                                              ITE      J13P3012                                            217        GERS        Cap> Dem Relays  Support Temperature Relay                              DGSOl          Cab. Generator Systems Page 83 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No. : RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
                        . *-        Component                                        Enclosure                                Component Evaluation Floor No. Unit                                                                                              Building              Basis for    Evaluation ID  j -- T.ype  System  Function Manufacturer Model 'No. ID          Type            Elev. (ft)
Capacity        Result AC/DC Control  Power  Lube Oil High                              lETB-      Control  Diesel 397  1  D14-0T2                                              ITE    J13P3012                                      217        GERS        Cap > Dem Relays  Support Temperature Relay                          DGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                              lETB-      Control  Diesel 398  1  D14-0T3                                              ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support  Temperature Relay                          DGSOl          Cab. Generator Systems AC/DC Control  Power                                              lETB-      Control  Diesel 399  1  D14-SDR                    Shutdown Relay          ITE    J13P3012                                      217        GERS        Cap> Dem Relays  Support                                            DGSOl          Cab. Generator Systems AC/DC Control  Power                                              lETB-      Control  Diesel 400  1  D14-SFR                    Start Failure Relay    ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support                                            DGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              2ETB-      Control  Diesel 401  2  D21-CP1                                            ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support Pressure Low Relay                          AGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              2ETB-      Control  Diesel 402  2  D21-CP2                                            ITE      Jl3P3012                                      217        GERS        Cap> Dem Relays  Support Pressure Low Relay                          AGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              2ETB-        Control  Diesel 403  2  D21-CP3                                            ITE      J13P3012                                    217        GERS        Cap>Dem Relays  Support Pressure Low Relay                          AGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                              2ETB-        Control  Diesel 404  2  D21-CT1                                            ITE      J13P3012                                    217        GERS        Cap> Dem Relays  Support Temperature Relay                          AGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                              2ETB-        Control  Diesel 405  2  D21-CT2                                            ITE      J13P3012                                    217        GERS        Cap> Dem Relays  Support Temperature Relay                          AGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                              2ETB-        Control  Diesel 406  2  D21-CT3                                            ITE      J13P3012                                    217        GERS        Cap> Dem Relays  Support Temperature Relay                          AGSOl          Cab. Generator Systems Page 84of110
 
15C4345-RPT-002, Rev. 0 Correspondence No. : RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 81 Component                                      IEnclosure                                  Component Evaluation
        -                                                                                                            Floor J[ rvi .] I Sys~ ~ction              ~ rM~ufacturer ~odel N; i                Typ~
No. :                                                                                                Building                  Basis for    Evaluation ID_                                                    11              ID      [                    I Elev. (ft)
Capacity        Result AC/DC Control  Powe r  Lube Oil Pressure                          2ETB-      Control  Diesel 407  2 D21-0P1                                            ITE      J13P3012                                        217        GERS        Cap > Dem Relays  Support  Low Relay                                AGSOl          Cab. Generato r Systems AC/DC Cont rol  Pow er  Lube Oil Pressure                          2ETB-      Control  Diesel 408  2 D21-0P2                                            ITE      J13P3012                                        217        GERS        Cap> Dem Relays  Support  Low Relay                                AGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil Pressure                          2ETB-      Control  Diesel 409  2 D21-0P3                                            ITE      J13P3012                                        217        GERS        Cap> Dem Rela ys Support  Low Relay                                AGSOl          Cab. Generat or Systems AC/DC Cont rol  Pow er  Lube Oil High                            2ETB-        Control  Diesel 410  2 D21-0Tl                                            ITE        J13 P3012                                      217        GERS        Cap> Dem Rela ys Support Temperature Relay                          AGSOl          Cab. Generato r Systems AC/DC Co ntrol  Power  Lube Oil High                            2ETB-        Control  Diesel 411  2 D21-0T2                                            ITE        J13P3012                                        217        GERS        Cap> Dem Rel ays Support Temperatu re Relay                        AGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                            2ETB-        Control  Diesel 412  2 D21-0T3                                            ITE        J13P3012                                        217        GERS        Cap> Dem Relays  Support Temperature Relay                          AGSOl          Cab. Generator Systems AC/DC Cont rol  Power                                            2ETB-        Control  Diesel 413  2 D21-SDR                      Shutdown Relay        ITE        J13P3012                                      217        GERS        Cap> Dem Relays  Support                                            AGSOl          Cab. Generator Systems AC/DC Cont rol  Pow er                                            2ETB-        Control  Diesel 414  2 D21-SFR                      Start Failure Relay  ITE        J13P3012                                      217        GERS        Cap> Dem Relays  Support                                            AGSOl          Cab. Generator Systems AC/DC Control  Pow er Jacket Cooling                            2ETB-        Control  Diesel 415  2 D22-CP1                                            ITE        J13P3012                                      217        GERS        Cap> Dem Relays  Support Pressure Low Relay                        BGSOl          Cab. Generator Systems AC/DC Cont rol  Pow er Jacket Cooling                            2ETB-        Control  Diesel 416  2 D22-CP2                                            ITE        J13P3012                                      217        GERS        Cap> Dem Rela ys  Support Pressure Low Relay                        BGSOl          Cab. Generato r Systems Page 85of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 81 Component                                              Enclosure                                Component Evaluation
                            ! (ivs~iij ~ction                                                                            J  Floor 1' Jl.~- !Y~                                        Manufa~rer ~ M;''!'!'l~J            ~]
No. '                                                    OM * ]                                                  Building                Basis for      Evaluation
          ,10                                                  [                            ID                            Elev. (ft)
Capacity        Result AC/DC Control    Pow er Jacket Cooling                                      2ETB-      Control  Diesel 417  2 D22-CP3                                                        ITE    J13P3012                                        217        GERS          Cap> Dem Relays    Support  Pressure Low Relay                                BGSOl          Cab. Generator Systems AC/DC Control    Power  Jacket Coolant                                      2ETB-      Control  Diesel 418  2 D22-CT1                                                        ITE    J13P3012                                        217        GERS        Cap> Dem Relays    Support Temperature Relay                                  BGSOl          Cab. Generator Systems AC/DC Control    Power  Jacket Coolant                                      2ETB-      Control  Diesel 419  2 D22-CT2                                                        ITE    J13P3012                                        217        GERS        Cap > Dem Relays    Support Temperature Relay                                  BGSOl          Cab. Generator Systems AC/DC Control    Power  Jacket Coolant                                      2ETB-      Control  Diesel 420  2 D22-CT3                                                        ITE    J13P3012                                        217        GERS        Cap> Dem Relays    Support Temperature Relay                                  BGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil Pressure                                  2ETB-      Control  Diesel 421  2 D22-0P1                                                        ITE    J13P3012                                      217        GERS        Cap> Dem Relays    Support Low Relay                                          BGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil Pressure                                  2ETB-      Control  Diesel 422  2 D22-0P2                                                      ITE      J13P3012                                      217        GERS        Cap> Dem Relays    Support Low Relay                                          BGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil Pressure                                  2ETB-        Control  Diesel 423  2 D22-0P3                                                      ITE      J13P3012                                      217        GERS        Cap> Dem Rela ys    Support Low Relay                                          BGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil High                                      2ETB-        Control  Diesel 424  2 D22-0T1                                                      ITE      J13P3012                                      217        GERS        Cap> Dem Relays    Support Temperature Relay                                  BGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil High                                      2ETB-        Control  Diesel 425  2 D22-0T2                                                      ITE      J13P3012                                      217        GERS        Cap> Dem Relays    Support Temperature Relay                                  BGSOl          Cab. Generator Systems AC/DC Control    Power  Lube Oil High                                      2ETB-        Control  Diesel 426  2 D22-0T3                                                      ITE      J13P3012                                      217        GERS        Cap> Dem Relays    Support Temperature Relay                                  BGSOl          Cab. Generat or Systems Page 86 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
          -                    component                                        Enclosure                                  Component Evaluation Floor No. Unit                                                                                          I  Building              Basis for    Evaluation ID  Type    System  Function            Manufacturer Model No. ID          Type              Elev. (ft)
Capacity        Result AC/DC Control  Power                                              2ETB-      Control    Diesel 427  2  D22-SDR                  Shutdown Relay          ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support                                            BGSOl          Cab. Generator Systems AC/DC Control  Power                                              2ETB-      Control    Diesel 428  2  D22-SFR                  Start Failure Relay      ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support                                            BGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              2ETB-      Control    Diesel 429  2  D23-CP1                                          ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support  Pressure Low Relay                        CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              2ETB-      Control    Diesel 430  2  D23-CP2                                          ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support  Pressure Low Relay                        CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                              2ETB-      Control    Diesel 431  2  D23-CP3                                          ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support  Pressure Low Relay                        CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                            2ETB-        Control    Diesel 432  2  D23-CT1                                          ITE      J13P3012                                      217        GERS        Cap> Dem Relays Support  Temperature Relay                          CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                              2ETB-        Control    Diesel 433  2  D23-CT2                                          ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support  Temperature Relay                          CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                              2ETB-        Control    Diesel 434  2  D23-CT3                                          ITE      Jl3P3012                                      217        GERS        Cap> Dem Relays  Support  Temperature Relay                          CGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil Pressure                          2ETB-        Control    Diesel 435  2  D23-0Pl                                          ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support Low Relay                                  CGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil Pressure                          2ETB-        Control    Diesel 436  2  D23-0P2                                          ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support Low Relay                                  CGSOl          Cab. Generator Systems Page 87 of 110
 
15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.
I Unit ID I
Type    System Component Function          Manufacturer ModeiNo. ID Enclosure Type  I BuHding  j  Floor Elev. {ft)
Component Evaluation
                                                                                                                              'Basis for    Evaluation Capacltv        Result AC/DC Control  Power  Lube Oil Pressure                        2ETB-      Control    Diesel 437    2  D23-0P3                                            ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support  Low Relay                                CGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                            2ETB-      Control    Diesel 438    2  D23-0Tl                                            ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support Temperature Relay                        CGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                            2ETB-      Control    Diesel 439    2  D23-0T2                                            ITE    J13P3012                                      217        GERS        Cap> Dem Relays Support Temperature Relay                        CGSOl          Cab. Generator Systems AC/DC Control  Power  Lube Oil High                            2ETB-      Control    Diesel 440    2  D23-0T3                                          ITE      J13P3012                                      217        GERS        Cap> Dem Relays Support Temperature Relay                        CGSOl          Cab. Generator Systems AC/DC Control  Power                                            2ETB-      Control    Diesel 441    2  D23-SDR                  Shutdown Relay          ITE      Jl3P3012                                      217        GERS        Cap> Dem Relays Support                                          CGSOl          Cab. Generator Systems AC/DC Control  Power                                            2ETB-        Control    Diesel 442    2  D23-SFR                  Start Failure Relay    ITE      J13P3012                                      217        GERS        Cap> Dem Relays Support                                          CGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                            2ETB-        Control    Diesel 443    2  D24-CP1                                          ITE      J13P3012                                      217        GERS        Cap>Dem Relays  Support Pressure Low Relay                        DGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                            2ETB-        Control    Diesel 444    2  D24-CP2                                          ITE      Jl3P3012                                      217        GERS        Cap> Dem Relays  Support Pressure Low Relay                        DGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Cooling                            2ETB-        Control    Diesel 445    2  D24-CP3                                          ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support Pressure Low Relay                        DGSOl          Cab. Generator Systems AC/DC Control  Power  Jacket Coolant                            2ETB-        Control    Diesel 446    2  D24-CT1                                          ITE      J13P3012                                      217        GERS        Cap> Dem Relays  Support Temperature Relay                        DGSOl          Cab. Generator Systems Page 88 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. II Unit r*
110  TvPe
                              ~ '
System Component Function          Manufacturer
* Model No. ID Enclosure Type Building    Floor I Elev. (ft)
I  Component Evaluation
                                                                                                                                      !Jaslsfor    Evaluation I                      I                                  Capacity        Result AC/DC Control      Power  Jacket Coolant                                2ETB-      Control  Diesel 447    2      D24-CT2                                              ITE      J13P3012                                      217          GERS        Cap> Dem Relays    Support Temperature Relay                            DG501          Cab. Generator Systems AC/DC Control      Power  Jacket Coolant                                2ETB-      Control  Diesel 448    2      D24-CT3                                              ITE      J13P3012                                      217          GERS        Cap> Dem Relays    Support Temperature Relay                            DG501          Cab. Generator Systems AC/DC Control      Power  Lube Oil Pressure                            2ETB-      Control  Diesel 449    2      D24-0P1                                              ITE      J13P3012                                      217          GERS        Cap> Dem Relays    Support  Low Relay                                  DG501          Cab. Generator Systems AC/DC Control      Power  Lube Oil Pressure                            2ETB-      Control  Diesel 450    2      D24-0P2                                              ITE      J13P3012                                      217          GERS        Cap> Dem Relays    Support  Low Relay                                  DG501          Cab. Generator Systems AC/DC Control      Power  Lube Oil Pressure                            2ETB-      Control  Diesel 451    2      D24-0P3                                            ITE        J13P3012                                      217          GERS        Cap> Dem Relays    Support  Low Relay                                  DG501          Cab. Generator Systems AC/DC Control      Power  Lube Oil High                                2ETB-        Control  Diesel 452    2      D24-0T1                                            ITE        J13P3012                                      217          GERS        Cap> Dem Relays      Support Temperature Relay                            DG501          Cab. Generator Systems AC/DC Control      Power  Lube Oil High                                2ETB-        Control  Diesel 453    2      D24-0T2                                            ITE        J13P3012                                      217          GERS        Cap>Dem Relays      Support Temperature Relay                            DG501          Cab. Generator Systems AC/DC Control      Power  Lube Oil High                                2ETB-        Control  Diesel 454    2      D24-0T3                                            ITE        Jl3P3012                                      217          GERS        Cap> Dem Relays      Support Temperature Relay                            DG501          Cab. Generator Systems AC/DC Control      Power                                              2ETB-        Control  Diesel 455    2      D24-SDR                    Shutdown Relay          ITE        Jl3P3012                                      217          GERS        Cap> Dem Relays      Support                                              DG501          Cab. Generator Systems AC/DC Control      Power                                              2ETB-        Control  Diesel 456    2      D24-SFR                    Start Failure Relay    ITE        J13P3012                                      217          GERS        Cap> Dem Relays      Support                                              DG501          Cab. Generator Systems Page 89of110
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                      Enclosure                                Component Evaluation No. !Jnit            - ~
Building Floor Basis for      Evaluation ID      Type  System  Function          Manufacturer  Model No. ID      I  Type            Elev. (ft)
          '--                                                                                                                    capacltv        Result AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 457  1      Dll-EOS                                        Honeywell              1A-G501                            217      EPRI HF Test    Cap> Dem Switch Support  Switch                            2RN7                Engine  Generator Systems AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 458  1      DlZ-EOS                                        Honeywell              1B-G501                            217      EPRI HF Test    Cap> Dem Switch Support  Switch                            2RN7                Engine  Generator Systems AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 459  1      D13-EOS                                        Honeywell              1C-G501                            217      EPRI HF Test    Cap> Dem Switch  Support  Switch                            2RN7                Engine  Generator Systems AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 460  1      D14-EOS                                        Honeywell              1D-G501                            217      EPRI HF Test    Cap> Dem Switch  Support Switch                            2RN7                Engine  Generator Systems AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 461  2      D21-EOS                                        Honeywell              2A-G501                            217      EPRI HF Test    Cap> Dem Switch  Support Switch                            2RN7                Engine  Generator Systems AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 462  2      D22-EOS                                        Honeywell              2B-GS01                            217      EPRI HF Test    Cap> Dem Switch  Support Switch                            2RN7                Engine  Generator Systems AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 463  2      D23-EOS                                        Honeywell              2C-G501                          217      EPRI HF Test      Cap> Dem Switch  Support Switch                            2RN7                Engine  Generator Systems AC/DC Process  Power  Engine Overspeed                  BZE6-                Diesel  Diesel 464  2      D24-EOS                                        Honeywell              2D-G501                          217      EPRI HF Test      Cap> Dem Switch  Support Switch                            2RN7                Engine  Generator Systems AC/DC TSH-GA-  Process  Power  Jacket Coolant                                          Diesel  Diesel              Qualification 465  1                                                    Allen Bradley  837-V3J  1A-G501                          217                        Cap> Dem llOA-1    Switch  Support Temperature Switch                                      Engine  Generator                  Test Systems AC/DC TSH-GA-  Process  Power  Jacket Coolant                                          Diesel  Diesel              Qualification 466  1                                                    Allen Bradley  837-V3J  1A-G501                          217                        Cap> Dem 110A-2    Switch  Support Temperature Switch                                      Engine  Generator                  Test Systems Page 90of110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation r
l_~nl~1 C                                                                                                ~ I Build!~
    '                                        Component                                                Enclosure    _J                          Component Evaluation l [.
Floor No.
ID        fype  l ~Ste~    Function          IManufacturer  II: Mooel No.      ID                          Elev. (ft)
Basis for Capacity Evaluation Result AC/DC TSH-GA-      Process    Power  Jacket Coolant                                                    Diesel  Diesel              Qualification 467      1                                                          Allen Bradley      837-V3J    lA-GSOl                            217                        Cap> Dem llOA-3      Switch  Support  Temperature Switch                                              Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Lube Oil High                                                    Diesel  Diesel              Qualification 468      1                                                          Allen Bradley      837-V3J    lA-GSOl                            217                        Cap> Dem 101A      Switch  Support Temperature Switch                                                Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Lube Oil High                                                    Diesel  Diesel              Qualification 469      1                                                          Allen Bradley      837-V3J    lA-GSOl                            217                        Cap> Dem 102A      Switch  Support Temperature Switch                                                Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Lube Oil High                                                    Diesel    Diesel              Qualification 470      1                                                          Allen Bradley      837-V3J    lA-GSOl                            217                        Cap> Dem 103A      Switch  Support Temperature Switch                                                Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Jacket Coolant                                                    Diesel    Diesel              Qualification 471      1                                                          Allen Bradley      837-V3J    lB-GSOl                          217                        Cap> Dem llOB-1      Switch  Support Temperature Swit ch                                              Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Jacket Coolant                                                    Diesel  Diesel              Qualification 472      1                                                          Allen Bradley      837-V3J    lB-GSOl                          217                        Cap > Dem llOB-2      Switch  Support Temperature Switch                                                Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Jacket Coolant                                                    Diesel  Diesel              Qualification 473      1                                                        Allen Bradley      837-V3J    10-GSOl                            217                        Cap>Dem llOB-3      Switch  Support Temperature Switch                                                Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Lube Oil High                                                    Diesel  Diesel              Qualification 474      1                                                        Allen Bradley      837-V3J    lB-GSOl                            217                        Cap> Dem 101B      Switch    Support Temperature Switch                                                Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Lube Oil High                                                    Diesel  Diesel              Qualification 475      1                                                        Allen Bradley      837-V3J    lB-GSOl                            217                        Cap> Dem 102B      Switch    Support Temperature Switch                                                Engine  Generator                Test Systems AC/DC TSH-GA-      Process    Power  Lube Oil High                                                    Diesel  Diesel              Qualification 476      1                                                        Allen Bradley      837-V3J    lB-GSOl                            217                        Cap> Dem 103B      Switch    Support Temperature Switch                                                Engine  Generator                Test Systems Page 91 of 110
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. 1~. Unit j l          - --                ~omponent Enclosure Building Floor Component Evaluation Basis for      Evaluation 110        ~ype  System  Function              Manufacturer  Model No. ID          Type            Elev. (ft)
              -                      -                                                                                                    Capacity          Result AC/DC TSH-GA-      Process  Power  Jacket Coolant                                              Diesel  Diesel              Qualification 477      1                                                            Allen Bradley  837-V3J  lC-GSOl                            217                        Cap> Dem llOC-1      Switch Support  Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Jacket Coolant                                              Diesel  Diesel              Qualification 478      1                                                            Allen Bradley  837-V3J  lC-GSOl                            217                      Cap> Dem llOC-2      Switch Support  Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Jacket Coolant                                              Diesel  Diesel              Qualification 479      1                                                            Allen Bradley  837-V3J  lC-GSOl                            217                      Cap> Dem llOC-3      Switch Support  Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Lube Oil High                                                Diesel  Diesel              Qualification 480      1                                                            Allen Bradley  837-V3J  lC-GSOl                            217                      Cap> Dem lOlC      Switch Support  Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Lube Oil High                                                Diesel  Diesel              Qualification 481      1                                                            Allen Bradley  837-V3J  lC-GSOl                            217                      Cap> Dem 102C        Switch Support  Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Lube Oil High                                                Diesel  Diesel              Qualification 482      1                                                            Allen Bradley  837-V3J  lC-GSOl                          217                        Cap> Dem 103C      Switch  Support  Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Jacket Coolant                                              Diesel  Diesel              Qualification 483      1                                                            Allen Bradley  837-V3J  lD-GSOl                            217                        Cap >Dem llOD-1      Switch  Support  Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Jacket Coolant                                              Diesel    Diesel              Qualification 484      1                                                            Allen Bradley  837-V3J  lD-GSOl                            217                        Cap> Dem llOD-2      Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Jacket Coolant                                              Diesel    Diesel              Qualification 485      1                                                            Allen Bradley  837-V3J  lD-GSOl                            217                        Cap> Dem llOD-3      Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-      Process  Power  Lube Oil High                                              Diesel    Diesel              Qualification 486      1                                                            Allen Bradley  837-V3J  lD-GSOl                            217                        Cap> Dem 101D      Switch  Support Temperature Switch                                          Engine  Generator                Test Systems Page 92 of 110
 
15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.
EJ! =  ID * - ] I~  T,ype s-, ~~ Fnct~
AC/DC Component 11 Manufacture~ G~el No. 1 I
ID Enclosure
[;~
                                                                                                        =i Building al  Floor Elev. (ft) I Component Evaluation Basis for Capacity Evaluation Result TSH-GA-        Process    Power  Lube Oil High                                            Diesel  Diesel                  Qualification 487  1                                                        Allen Bradley 837-V3J    lD-GSOl                              217                        Cap> Dem 102D          Switch    Support  Temperature Switch                                      Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Lube Oil High                                            Diesel  Diesel                  Qualification 488  1                                                        Allen Bradley 837-V3J    lD-GSOl                              217                        Cap> Dem 103D        Switch    Support  Temperature Switch                                      Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Jacket Coolant                                            Diesel  Diesel                  Qualification 489  2                                                        Allen Bradley 837-V3J    2A-G501                              217                        Cap> Dem 210A-1        Switch    Support  Temperature Switch                                      Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Jacket Coolant                                            Diesel  Diesel                  Qualification 490  2                                                        Allen Bradley 837-V3J    2A-G501                              217                        Cap> Dem 210A-2        Switch    Support  Temperature Switch                                      Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Jacket Coolant                                            Diesel  Diesel                  Qualification 491  2                                                        Allen Bradley 837-V3J    2A-GS01                              217                        Cap> Dem 210A-3        Switch    Support  Temperature Switch                                      Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Lube Oil High                                            Diesel  Diesel                  Qualification 492  2                                                        Allen Bradley 837-V3J    2A-G501                              217                        Cap> Dem 201A        Switch    Support Temperature Switch                                        Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Lube Oil High                                              Diesel  Diesel                  Qualification 493  2                                                        Allen Bradley 837-V3J    2A-G501                              217                        Cap>Dem 202A        Switch    Support Temperature Switch                                        Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Lube Oil High                                              Diesel  Diesel                  Qualification 494  2                                                        Allen Bradley 837-V3J    2A-G501                            217                          Cap> Dem 203A        Switch    Support Temperature Switch                                        Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Jacket Coolant                                            Diesel  Diesel                  Qualification 495  2                                                        Allen Bradley 837-V3J    2B-G501                            217                          Cap> Dem 2106-1        Switch    Support Temperature Switch                                        Engine  Generator                    Test Systems AC/DC TSH-GA-        Process    Power  Jacket Coolant                                            Diesel  Diesel                  Qualification 496  2                                                        Allen Bradley 837-V3J    2B-G501                            217                          Cap> Dem 2108-2        Switch    Support Temperature Switch                                        Engine  Generator                    Test Systems Page 93 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.
j 81    ltl H Component Type~ (~;te~ Enction          I    rMan~cturer I~ ModeiN~
ID Enclosure Type
                                                                                                      ,je:i:1ng]    Floor Elev. (ftJ Component Evaluation Basis for Capatity Evaluation Result AC/DC TSH-GA-  Process  Power  Jacket Coolant                                              Diesel    Diesel              Qualification 497  2                                                Allen Bradley  837-V3J    2B-GS01                            217                        Cap> Dem 210B-3    Switch  Support  Temperature Switch                                        Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Lube Oil High                                              Diesel    Diesel              Qualification 498  2                                                Allen Bradley  837-V3J    2B-GS01                            217                        Cap> Dem 2018    Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Lube Oil High                                              Diesel    Diesel              Qualification 499  2                                                Allen Bradley  837-V3J    2B-GS01                            217                        Cap> Dem 202B    Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Lube Oil High                                                Diesel    Diesel              Qualification soo  2 203B    Switch          Temperature Switch Allen Bradley  837-V3J    2B-GS01 Engine  Generator 217                        Cap>Dem Support                                                                                                Test Systems AC/DC TSH-GA-  Process  Power  Jacket Coolant                                              Diesel    Diesel              Qualification 501  2                                                Allen Bradley  837-V3J  2C-G501                              217                        Cap> Dem 210C-1    Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Jacket Coolant                                              Diesel    Diesel              Qualification S02  2                                                Allen Bradley  837-V3J  2C-GS01                            217                        Cap> Dem 210C-2  Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Jacket Coolant                                              Diesel    Diesel              Qualification 503  2                                                Allen Bradley  837-V3J  2C-G501                            217                        Cap> Dem 210C-3  Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Lube Oil High                                                Diesel    Diesel              Qualification 504  2                                                Allen Bradley  837-V3J  2C-G501                            217                        Cap> Dem 201C    Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Lube Oil High                                              Diesel    Diesel              Qualification 50S  2                                                Allen Bradley  837- V3J  2C-GS01                            217                        Cap> Dem 202C    Switch  Support Temperature Switch                                          Engine  Generator                Test Systems AC/DC TSH-GA-  Process  Power  Lube Oil High                                              Diesel    Diesel              Qualification 506  2                                                Allen Bradley  837-V3J  2C-G501                            217                        Cap> Dem 203C    Switch  Support Temperature Switch                                          Engine  Generator                Test Systems Page 94of110
 
15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I
    ~ ~nl~ t= ~~o =J L Tv~~] j                                                                                  B~dl:J
                -                        Component                                        Enclosure                                  -Component Evaluation Floor
                                          ~ction          _J ; Manufacture~              ID      ~I No.                                                                                                                                    Basis for        Evaluation Model No.                                  Elev. (ft)
System]                                                                                            Capacltv          Result AC/DC TSH-G A-  Process    Power  Jacket Coolant                                            Diesel    Diesel              Qualification 507    2                                                        Allen Bradley  837-V3J  2D-G501                              217                        Cap > Dem 210D-1    Switch  Support Temperature Switch                                        Engine    Generator                Test Systems AC/DC TSH-GA-    Process    Power  Jacket Coolant                                            Diesel    Diesel              Qualification 508    2                                                        Allen Bradley  837-V3J  2D-G501                              217                        Cap > Dem 210D-2    Switch  Support Temperature Switch                                        Engine    Generator                Test Systems AC/DC TSH-GA-    Process    Power  Jacket Coolant                                            Diesel    Diesel              Qualification 509    2                                                        Allen Bradley  837-V3J  2D-G501                              217                        Cap> Dem 210D-3    Switch  Support Temperature Switch                                        Engine    Generator                Test Systems AC/DC TSH-GA-    Process    Power  Lube Oil High                                            Diesel    Diesel              Qualification 510    2                                                        Allen Bradley  837-V3J  2D-G501                            217                        Cap> Dem 2010    Switch    Support Temperature Switch                                        Engine    Generator                Test Systems AC/DC TSH-GA-    Process    Power  Lube Oil High                                              Diesel    Diesel              Qualification 511    2                                                        Allen Bradley  837-V3J  2D-G501                              217                        Cap> Dem 202D    Switch    Support Temperature Switch                                        Engine    Generator                Test Systems AC/DC TSH-G A-    Process    Power  Lube Oil High                                              Diesel    Diesel              Qualification 512    2                                                        Allen Bradley  837-V3J  2D-G501                            217                        Cap> Dem 203D    Switch    Support Temperature Switch                                        Engine    Generator                Test Systems Load AC/DC Low Voltage                                                                  Center D114-33                Power  D114-D-G Motor                      K-600                          Reactor              Qualification 513    1 (52-20133)
Circuit Support Control Center ABB/ITE Breaker D114-33          I    Enclosure 313 Test Cap> Dem Breaker                                                                    Switch Systems gear Load AC/DC Low Voltage        D114-R-G Motor                                            Center D114-32                Power                                      K-600                          Reactor              Qualification 514    1 (52-20132)
Circuit Support Control Center          ABB/ITE Breaker D114-32          I    Enclosure 313 Test Cap> Dem Breaker          Circuit Breaker                                          Switch Systems gear Load AC/DC Low Voltage                                                                  Center D124-33                Power  D124-D-G Motor                      K-600                          Reactor              Qualification 515    1 (52-20233)
Circuit Support Control Center ABB/ITE Breaker D124-33          I    Enclosure 313 Test Cap> Dem Breaker                                                                    Switch Systems gear Page 95 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
    ~
Component                                  Enclosure                                Component Evaluation I                    -                                                                              Building j r F.loor No. * . Unit                                                                              ID                          Elev. (ft)
Basis for        Evaluation
                *10            Type    System  Function        Manufacturer Model No.              Type
                        ..J Capacltv          Result Load AC/DC Low Voltage          D124-R-G Motor                                    Center D124-32                    Power                                  K-600                      Reactor                Qualification 516      1                    Circuit            Control Center    ABB/ITE Breaker D124-32        I  Enclosure 313 Test Cap> Dem (52-20232)                Support Breaker            Circuit Breaker                                    Switch Systems gear Load AC/DC Low Voltage                                                            Center D134-33                    Power  D134-D-G Motor                K-600                      Reactor                Qualification 517      1                    Circuit Control Center ABB/ITE Breaker D134-33        I  Enclosure 253 Test Cap> Dem (52-20333)                Support Breaker                                                              Switch Systems gear Load AC/DC Low Voltage          D134-R-E Motor                                    Center D134-24                    Power                                  K-600                      Reactor                Qualification 518      1                    Circuit            Control Center    ABB/ITE Breaker D134-24        I  Enclosure 253 Test Cap> Dem (52-20324)                Support Breaker            Circuit Breaker                                    Switch Systems gear Load AC/DC Low Voltage                                                            Center D144-33                    Power  D144-D-G Motor                K-600                      Reactor                Qualification 519      1                    Circuit Control Center ABB/ITE Breaker D144-33        I  Enclosure 283 Test Cap> Dem (52-20433)                Support Breaker                                                              Switch Systems gear Load AC/DC Low Voltage          D144-R-E Motor                                    Center D144-24                    Power                                  K-600                      Reactor                Qualification 520      1                    Circuit            Control Center    ABB/ITE Breaker D144 -24        I  Enclosure 283 Test Cap> Dem (S2-20424)                Support Breaker            Circuit Breaker                                    Switch Systems gear Load AC/DC Low Voltage                                                            Center D214-33                    Power  D214-D-G Motor                K-600                      Reactor                Qualification 521      2                    Circuit Control Center ABB/ITE Breaker D214-33        I  Enclosure 313 Test Cap> Dem (52-20133)                Support Breaker                                                              Switch Systems gear Load AC/DC Low Voltage          D214-R-G Motor                                    Center 0214-32                    Power                                  K-600                      Reactor                Qualification 522      2                    Circuit            Control Center    ABB/ITE Breaker D214-32        I  Enclosure 313 Test Cap> Dem
{52-20132)                Support Breaker            Circuit Breaker                                    Switch Systems gear Load AC/DC Low Voltage                                                            Center D224-33                    Power  0224-D-G Motor                K-600                      Reactor                Qualification 523      2                    Circuit Support  Control Center ABB/ITE Breaker D224-33        I  Enclosure 313 Test Cap> Dem
{52-20233)
Breaker                                                              Switch Systems gear Page 96 of 11 O
 
1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component                                    Enclosure I-                                                                                                                          Component Evaluation
                                                                                                              ~              Floor INo. 1 Unit
[                        I 110 .~J LTv~-=_] Sys~e~J    [_FUnction ..
                                                                  ~ ~anufacturer I~ N~      ID      [ iype ]
Building  Elev. {ft)
Basis for caoacitV Evaluation Result Load AC/DC Low Voltage            D224-R-G Motor                                      Center D224-32                Power                                      K-600                        Reactor              Qualification 524    2
{52-20232)
Circuit Support Control Center      ABB/ITE Breaker D224-32        I    Enclosure 313 Test Cap> Dem Breaker              Circuit Breaker                                      Switch Systems gear Load AC/DC Low Voltage                                                                Center D234-33                  Power    D234-D-G Motor                    K-600                        Reactor              Qualification 525    2 (52-20333)
Circuit Support  Control Center ABB/ITE Breaker D234-33        I    Enclosure 253 Test Cap> Dem Breaker                                                                  Switch Systems gear Load AC/DC Low Voltage            D234-R-E Motor                                      Center D234-24                  Power                                      K-600                        Reactor              Qualification 526    2
{52-20324)
Circuit Support Control Center      ABB/ITE Breaker D234-24        I    Enclosure 253 Test Cap> Dem Breaker              Circuit Breaker                                      Switch Systems gear Load AC/DC Low Voltage                                                                Center D244-33                  Power    D244-D-G Motor                    K-600                        Reactor              Qualification 527    2 (52-20433)
Circuit Support  Control Center ABB/ITE Breaker D244-33        I    Enclosure 283 Test Cap> Dem Breaker                                                                  Switch Systems gear Load AC/DC Low Voltage            D244-R-E Motor                                      Center D244-24                  Power                                      K-600                        Reactor              Qualification 528    2
{52-20424)
Circuit Support Control Center      ABB/ITE Breaker D244-24        I    Enclosure 283 Test Cap> Dem Breaker              Circu it Breaker                                    Switch Systems gear Page 97 of 110
 
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I                  -
VAi.VE Ill> (Qn                *' I PIMSID.        I  P&ID  f .SHEET              Notes                I    Evaluated in Ref. [1:8]
P&ID HV-lFOOl      HV-041-lFOOl        M-0041      1                                                  Yes*
HV-1F002      HV-041-1F002        M-0041      1                                                  Yes*
NORMALLY OPEN TO MAIN STEAM LINE C. NOT A LEAK PATH HV-lFOOS      HV-041-lFOOS        M-0041      1                                                    No (No Need to be included- Line C is isolated)
DOWN STREAM CHECK VALVE HV-HV-lFOllA      HV-041-lFOllA        M-0041      1  lFOlOA will provide Boundary (No                No Need to be included)
SIMPLE CHECK VALVE (No Need to lFOlOA        041-lFOlOA        M-0041      1                                                    No be included)
DOWN STREAM OF CHECK VALVE HV-1F074A      HV-041-1F074A        M-0041      1                                                    No (No Need to be included)
DOWN STREAM CHECK VALVE HV-HV-lFOllB      HV-041-lFOllB        M-0041      1  lFOlOB will provide Boundary (No                No Need to be included)
SIMPLE CHECK VALVE (No Need to lFOlOB        041-lFOlOB        M-0041      1                                                    No be included)
DOWN STREAM OF CHECK VALVE HV-1F074B      HV-041-1F074B        M-0041      1                                                    No (No Need to be included)
PSV-1F013A      PSV-041-1F013A      M-0041      2                  SRV                              Yes*
Page 98of110
 
15C4345-RPT-002, Rev. a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE Ill> on i'                I PIMSID        P&ID      SHEET                Notes                      Evaluated in Ref., [18)
P&ID PSV-1F013B      PSV-041-1F013B  M-0041      2                  SRV                                Yes*
PSV-1F013C      PSV-041-1F013C  M-0041      2                  SRV                                Yes*
PSV-1F013D      PSV-041-1F013D  M-0041      2                  SRV                                Yes*
PSV-1F013E      PSV-041-1F013E  M-0041      2                  SRV                                Yes*
PSV-1F013F      PSV-041-1F013F  M-0041      2                  SRV                                Yes*
PSV-1F013G      PSV-041-1F013G  M-0041      2                  SRV                                Yes*
PSV-1F013H      PSV-041-1F013H  M-0041      2                  SRV                                Yes*
PSV-1F013J      PSV-041-1F013J  M-0041      2                  SRV                                Yes*
PSV-1F013K      PSV-041-1F013K  M-0041      2                  SRV                                Yes*
PSV-1F013L      PSV-041-1F013L  M-0041      2                  SRV                                Yes*
PSV-041-PSV-1F013M                        M-0041      2                  SRV                                Yes*
1F013M PSV-1F013S      PSV-041-1F013S  M-0041      2                  SRV                                Yes*
PSV-1F013N      PSV-041-1F013N  M-0041      2                  SRV                                Yes*
HV-F022A      HV-041-1F022A    M-0041      2                                                      Yes*
HV-F028A      HV-041-1F028A    M-0041      2                                                      Yes*
HV-F022B      HV-041-1F022B    M-0041      2                                                      Yes*
Page 99of110


===3.4 COMPONENT===
15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation V~LVE  ID on IP&ID
[    PIMS l D  J  P&ID rH~~T I  l                Notes l      Evaluated in Ref. [18]
HV-F028B          HV-041-1F028B    M-0041      2                                                        Yes*
HV-F022C          HV-041-1F022C    M-0041      2                                                        Yes*
HV-F028C          HV-041-1F028C    M-0041      2                                                        Yes*
HV-F022D          HV-041-1F022D    M-0041      2                                                        Yes*
HV-F028D          HV-041-1F028D    M-0041      2                                                        Yes*
HV-C-F020        HV-C-041-1F020  M-0041      2                                                        Yes*
HV-1F016          HV-041-lFOlG    M-0041      2        Normally Closed Drain Line                    Yes*
Normally Closed Drain Line would No - See notes and discussion in HV-1F019          HV-041-1F019    M-0041      2      only be a Leak Path if HV-1F016 Section 2.2 of this report.
Opens Normally Open- Need to check if HV-lFlOS          HV-044-lFlDS    M-0044      1                                                        Yes*
there is a signal to close Would only be a Leak Path if HV-    No - See notes and discussion in HV-lFOOl          HV-044-lFOOl    M-0044      1 lFlOS fails to be closed        Section 2.2 of this report.
Would only be a Leak Path if HV-    No - See notes and discussion in HV-1F004          HV-044-1F004    M-0044      1 lFlOS fails to be closed        Section 2.2 of this report.
Normally Open- Need to check if HV-lFlOO          HV-044-lFlOO    M-0044      1                                                        Yes*
there is a signal to close Page 100of110


VERTICAL SEISMIC DEMAND The component vertical demand is determined using the peak acceleration of the VG MRS between 15 Hz and 40 Hz and amplifying it using the following two factors:
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation
* Vertical in-structure amplification factor AFsv to account for seismic amplification at floor elevations above the host building's foundation Page 21of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177
                                ~~        l ;HE~
* Verti cal in-cabinet amplification factor AFc to account for seismic amplification within the host equipment (cabinet, switchgear, motor control center, etc.) The in-structure amplification factor AFsv is derived from Figure 4-4 in Reference
[~
[8]. The cabinet vertical amplification factor, AFc is derived in Reference
VAl!.VE ID on P&ID HV-1F007 I
[8] and is 4.7 for all cabinet types. Page 22of110 4 Contact Device Evaluations 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Per Reference
PIMS ID HV-049-1F007    M-0049
[8], seismic capacities (the highest seismic test level reached by the contact device without chatter or other malfunction) for each subject contact device are determined by the following procedures:
___J 1
(1) If a contact device was tested as part of the EPRI High Frequency Testing program [7], then the component seismic capacity from this program is used. (2) If a contact device was not tested as part of [7], then one or more of the following means to determine the component capacity were used: (a) Device-specific seismic test reports (either from the station or from the SQURTS testing program. (b) Generic Equipment Ruggedness Spectra (GERS) capacities per [9], [10], [11], and [12]. (c) Assembly (e.g. electrical cabinet) tests where the component functional performance was monitored.
Notes Normally Open- Need to check if there is a signal to close l'      Evaluated in Ref. (18]
The high-frequency capacity of each device was evaluated with the component mounting point demand from Section 3 using the criteria in Section 4.5 of Reference
Yes*
[8] A summary of the high-frequency evaluation conclusions is provided in Table B-1 in Appendix B of this report. Page 23 of 11 o 5 Conclusions
Would only be a Leak Path if HV-    No - See notes and discussion in HV-1F008      HV-049-lFOOS    M-0049      1 1F107 fails to be closed          Section 2.2 of this report.
Per the Plant this is the Containment Spray Valves and HV-1F021A      HV-051-1F021A    M-0051      1                                                   No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-1F016A      HV-051-1F016A    M-0051      1                                                  No - See Note does not communicate with the Reactor HV-1F041C      HV-051-1F041C    M-0051      1                CHECK VALVE                            Yes*
No - See notes and discussion in HV-1F017C      HV-051-1F017C    M-0051      1      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
HV-1F041A      HV-051-1F041A    M-0051      1                CHECK VALVE                            Yes*
No - See notes and discussion in HV-1F017A      HV-051-1F017A    M-0051      1      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
HV-1F050A      HV-051-1F050A    M-0051      1                CHECK VALVE                            Yes*
No - See notes and discussion in HV-1F015A      HV-051-1F015A    M-0051      1     DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
Page 101 of 110


===5.1 GENERAL===
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE ID on PIMSID        P&ID    I SHEET                Notes              I      Evaluated in 1Ref. [18)
CONCLUSIONS 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 LIM has performed a High Frequency Confirmation evaluation in response to the NRC's 50.54(f) letter [1] using the methods in EPRI report 3002004396
P&ID HV-1F008    HV-051-lFOOB    M-0051      1                                                       Yes*
[8]. The evaluation identified a total of 528 components that required evaluation.
Per the Plant this is the Containment Spray Valves and HV-1F021B  HV-M51-1F021B    M-0051      3                                                  No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-1F016B  HV-051-1F016B    M-0051      3                                                  No - See Note does not communicate with the Reactor HV-1F041D  HV-051-1F041D    M-0051      3                CHECK VALVE                            Yes*
As summarized in Table B-1 in Appendix B, all of the devices have adequate seismic capacity for the reevaluated seismic hazard [4]. 5.2 IDENTIFICATION OF FOLLOW-UP ACTIONS No follow-up actions were identified.
No - See notes and discussion in HV-1F017D  HV-051-1F017D    M-0051      3      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
Page 24of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 6 References 1 NRC (E. Leeds and M. Johnson) Letter to All Power Reactor Licensees et al., "Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f} Regarding Recommendations 2.1, 2.3 and 9.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident," March 12, 2012, ADAMS Accession Number ML12053A340 2 NRC (W. Dean) Letter to the Power Reactor Licensees on the Enclosed List. "Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54{f} Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident." October 27, 2015, ADAMS Accession Number ML15194A015 3 NRC (J. Davis) Letter to Nuclear Energy Institute (A. Mauer). "Endorsement of Electric Power Research Institute Final Draft Report 3002004396, 'High Frequency Program: Application Guidance for Functional Confirmation and Fragility."'
HV-1F041B  HV-051-1F041B    M-0051      3               CHECK VALVE                              Yes No - See notes and discussion in HV-1F017B  HV-051-1F017B    M-0051      3      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
September 17, 2015, ADAMS Accession Number ML15218A569 4 Seismic Hazard and Screening Report in Response to the 50.54{f) Information Request Regarding Fukushima Near-Term Task Force Recommendation 2.1: Seismic for Limerick Generating Station, Unit 1 and 2 dated March 31, 2014, ADAMS Accession Number ML14090A236 5 Not Used 6 EPRI 1025287, "Seismic Evaluation Guidance:
HV-1F050B  HV-051-1F050B    M-0051      3               CHECK VALVE                            Yes*
Screening, Prioritization and Implementation Details (SPID} for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic." February 2013 7 EPRI 3002002997, "High Frequency Program: High Frequency Testing Summary." September 2014 8 EPRI 3002004396, "High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation
No - See notes and discussion in HV-1F015B  HV-051-1F015B    M-0051      3      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
." July 2015 9 EPRI NP-7147-SL, "Seismic Ruggedness of Relays." August 1991 10 EPRI NP-7147-SLV2, Addendum 1, "Seismic Ruggedness of Relays", September 1993 11 EPRI NP-7147-SLV2, Addendum 2, "Seismic Ruggedness of Relays", April 1995 12 EPRI NP-7147 SQUG Advisory 2004-02, "Relay GERS Corrections." September 10, 2004 13 EPRI NP-7148-SL, "Procedure for Evaluating Nuclear Power Plant Relay Seismic Functionality", 1990 14 NRC {F. Vega) Letter to Limerick Generating Station (B. Hanson), "Limerick Generating Station, Unit 1 and 2 -Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54{f), Seismic Hazard Reevaluations for Recommendation
HV-1F009    HV-051-1F009    M-0051      3                                                        Yes*
HV-1F006B  HV-052-lFOOGB    M-0052      1               CHECK VALVE                            Yes*
Page 102 of 110


===2.1 ofthe===
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMSID~ 1 P&ID                  l-~-
Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident (TAC NOS. MF3864 and MF3865)." November 6, 2015, ADAMS Accession Number ML15296A492 15 Recommendations For Enhancing Reactor Safety in the 21'1 Century, "The Near-Term Task Force Review of Insights from the Fukushima Dai-I chi Accident" July 12, 2011, ADAMS Accession Number ML111861807 16 NEI 12-06, Rev. 2, "Diverse and Flexible Coping Strategies
[                        ~:1 VAl.\VE ID on !
{FLEX) Implementation Guide" Page 25 of 11 O 1SC434S-RPT-002, Rev. 0 Correspondence No.: RS-16-177 17 1SC434S-CAL-001, Rev. 2, "High Frequency Functional Confirmation and Fragility Evaluation of Relays" 18 1SC434S-RPT-001, Rev. 3, "Selection of Relays and Switches for High Frequency Seismic Evaluation" 19 Limerick Drawing ESl-1040-E-003 Rev. 32, Elementary Diagram Reactor Core Isolation 20 Limerick Drawing ESl-1040-E-013 Rev. 16, Elementary Diagram RCIC System Sheet 3A 21 Limerick Drawing ESl-1040-E-004 Rev. 30, Elementary Diagram Reactor Core Isolation 22 Limerick Drawing ESl-1040-E-014 Rev. 16, Elementary Diagram RCIC System Sheet 4A 23 Limerick Drawing M-0041Sheet1Rev.47, Piping and Instrument Diagram Nuclear Boiler 24 Limerick Drawing M-0041 Sheet 3 Rev. SS, Piping and Instrument Diagram Nuclear Boiler 2S Limerick Drawing M-0041Sheet4 Rev. 43, Piping and Instrument Diagram Nuclear Boiler 26 Limerick Drawing M-0041 Sheet 6 Rev. SS, Piping and Instrument Diagram Nuclear Boiler 27 Limerick Drawing B21-1060-E-004 Rev. 14, Elementary Diagram Automatic De pressurization System Sheet 4 28 Limerick Drawing B21-1060-E-OOS Rev. 13, Elementary Diagram Automatic Depressurization System Sheet S 29 Limerick Drawing B21-1060-E-018 Rev. 7, Elementary Diagram Automatic Depressurization System 30 Limerick Drawing B21-1060-E-019 Rev. 6, Elementary Diagram Automatic Depressurization System 31 Limerick Drawing B21-1060-E-003 Rev. 16, Elementary Diagram Automatic Depressurization System 32 Limerick Drawing B21-1060-E-01S Rev. S, Elementary Diagram Auto Depressurization System 33 Limerick Drawing B21-1060-E-008 Rev. 14, Elementary Diagram Auto Depressurization System Sheet 3A 34 Limerick Drawing B21-1060-E-016 Rev. 4, Elementary Diagram Auto Depressurization System Sheet 3A 3S Limerick Drawing B21-1060-E-006 Rev. 19, Elementary Diagram Auto Depressurization System Sheet 6 36 Limerick Drawing B21-1060-E-011Rev.12, Elementary Diagram Auto Depressurization System Sheet 6A 37 Limerick Drawing B21-1060-E-020 Rev. 7, Elementary Diagram Auto Depressurization System 38 Limerick Drawing B21-1060-E-021 Rev. 6, Elementary Diagram Auto Depressurization System 39 Limerick Drawing B21-1090-E-010 Rev. 23, Elementary Diagram Nuclear Steam Supply Shutoff System 40 Limerick Drawing B21-1090-E-011 Rev. 23, Elementary Diagram Nuclear Steam Supply Shutoff System 41 Limerick Drawing B21-1090-E-027 Sheet 10 Rev. 8, Elementary Diagram Reactor Core Isolation 42 Limerick Drawing B21-1090-E-027 Sheet 11 Rev. 9, Elementary Diagram Nuclear Steam Supply Shutoff System Page 26 of 11 O 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 43 Limerick Drawing B21-1090-E-006 Rev. 27, Elementary Diagram Nuclear Steam Supply Shutoff System Sheet 6 44 Limerick Drawing B21-1090-E-007 Rev. 25, Elementary Diagram Nuclear Steam Supply Shutoff System Sheet 7 45 Limerick Drawing B21-1090-E-027 Sheet 6 Rev. 7, Elementary Diagram Nuclear Steam Supply Shutoff System 46 Limerick Drawing B21-1090-E-027 Sheet 7 Rev. 8, Elementary Diagram Nuclear Steam Supply Shutoff System 47 Limerick Drawing B21-1040-E-004 Rev. 23, Elementary Diagram Nuclear Boiler Process 48 Limerick Drawing B21-1040-E-008 Rev. 8, Elementary Diagram Nuclear Boiler Process 49 Limerick Drawing B21-1040-E-009 Rev. 9, Elementary Diagram Nuclear Boiler Process 50 Limerick Drawing B21-1090-E-032 Sheet 1 Rev. l, HV-041-1F016 Main Steam Drain Inboard PCIV Steam Drains Inboard 51 Limerick Drawing B21-1090-E-038 Sheet 1 Rev. 0, Elementary Diagram HV-051-2F016 52 Limerick Drawing G31-1040-E-001 Rev. 46, Elementary Diagram Reactor Water Cleanup System 53 Limerick Drawing G31-1040-E-005 Rev. 24, Elementary Diagram Reactor Water Cleanup System 54 Limerick Drawing B21-1090-E-012 Rev. 29, Elementary Diagram Nuclear Steam Supply Shutoff System 55 Limerick Drawing B21-1090-E-016 Sheet 2 Rev. 4, Elementary Diagram Nuclear Steam Supply Shutoff System 56 Limerick Drawing B21-1090-E-027 Sheet 12 Rev. 16, Elementary Diagram Nuclear Steam Supply Shutoff System 57 Limerick Drawing B21-1090-E-027 Sheet 2A Rev. 15, Elementary Diagram Nuclear Steam Supply Shutoff System 58 Limerick Drawing B21-1090-E-008 Rev. 32, Elementary Diagram Nuclear Steam Supply Sheet 8 59 Limerick Drawing B21-1090-E-017 Rev. 33, Elementary Diagram Nuclear Steam Supply Sheet 8A 60 Limerick Drawing B21-1090-E-027 Sheet 8 Rev. 16, Elementary Diagram Nuclear Steam Supply Shutoff System 61 Limerick Drawing B21-1090-E-027 Sheet 8A Rev. 14, Elementary Diagram Nuclear Steam Supply Shutoff System 62 Limerick Drawing ESl-1040-E-052 Sheet 1 Rev. l, Schematic HV-049-1F007 Main Steam Supply Inboard PCIV Inboard 63 Limerick Drawing ESl-1040-E-053 Sheet 1 Rev. 2, Schematic HV-049-1F008 RCIC Steam Line Outboard PCIV Outboard 64 Limerick Drawing ESl-1040-E-056 Sheet 1Rev.1, Elementary Diagram HV-049-2F007 65 Limerick Drawing ESl-1040-E-057 Sheet 1 Rev. 1, Elementary Diagram HV-049-2F008 66 Limerick Drawing Ell-1040-E-016 Rev. 35, Elementary Diagram Residual Heat Removal System 67 Limerick Drawing Ell-1040-E-018 Rev. 35, Elementary Diagram Residual Heat Removal System Page 27 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 68 Limerick Drawing Ell-1040-E-019 Rev. 32, Elementary Diagram Residual Heat Removal System 69 Limerick Drawing Ell-1040-E-020 Rev. 23, Elementary Diagram Residual Heat Removal System 70 Limerick Drawing Ell-1040-E-021 Rev. 21, Elementary Diagram Residual Heat Removal System 71 Limerick Drawing Ell-1040-E-049 Rev. 17, Elementary Diagram Residual Heat Removal System 72 Limerick Drawing Ell-1040-E-051Rev.16, Elementary Diagram Residual Heat Removal System 73 Limerick Drawing Ell-1040-E-052 Rev. 15, Elementary Diagram Residual Heat Removal System 74 Limerick Drawing Ell-1040-E-053 Rev. 10, Elementary Diagram Residual Heat Removal System 75 Limerick Drawing Ell-1040-E-054 Rev. 11, Elementary Diagram Residual Heat Removal System 76 Limerick Drawing B21-1090-E-018 Sheet 2 Rev. 4, Elementary Diagram Nuclear Steam Supply Shutoff System 77 Limerick Drawing B21-1090-E-033 Sheet 1Rev.1, Schematic HV-051-1F009 RHR Shutdown Cooling Suction Inboard PCI Inboard 78 Limerick Drawing B21-1090-E-034 Sheet 1 Rev. 1, Elementary Diagram HV-051-2F008 79 Limerick Drawing B21-1090-E-035 Rev. 1, Elementary Diagram HV-051-2F009 80 Limerick Drawing E21-1040-E-009 Rev. 25, Elementary Diagram Core Spray System 81 Limerick Drawing E21-1040-E-010 Rev. 22, Elementary Diagram Core Spray System 82 Limerick Drawing E21-1040-E-030 Rev. 9, Elementary Diagram Core Spray System 83 Limerick Drawing E21-1040-E-031 Rev. 8, Elementary Diagram Core Spray System 84 Limerick Drawing E41-1040-E-014 Sheet 2 Rev. 1, Elementary Diagram HPCI System 85 Limerick Drawing E41-1040-E-013 Sheet 2 Rev. 0, Elementary Diagram HPCI System 86 Limerick Drawing E41-1040-E-027 Sheet 2 Rev. 0, Elementary Diagram HPCI System Sheet 11 87 Limerick Drawing E41-1040-E-027 Sheet 6 Rev. 0, Elementary Diagram HPCI System 88 Limerick Drawing E41-1040-E-006 Rev. 36, Elementary Diagram HPCI System 89 Limerick Drawing E41-1040-E-022 Rev. 8, Elementary Diagram HPCI System 90 Limerick Report, "Updated Final Safety Analysis Report (UFSAR)," Rev. 18, September 2016 91 Limerick Drawing E-0015 Sheet 1 Rev. 30, Single Line Meter and Relay Diagram 4KV Safeguard Power System Unit 1 92 Limerick Drawing E-0016 Sheet 1 Rev. 26, Single Line Meter and Relay Diagram 4KV Safeguard Power System Unit 2 93 Limerick Drawing E-0033 Sheet 1 Rev. 45, Single Line Meter and Relay Diagram 125, 250VDC System 94 Limerick Drawing E-0033 Sheet 2 Rev. 47, Single Line Meter and Relay Diagram 125, 250VDC System 95 Limerick Drawing E-0034 Sheet 1 Rev. 38, Single Line Meter and Relay Diagram 125, 250V DC System Page 28 of 11 O 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 96 Limerick Drawing E-0034 Sheet 2 Rev. 40, Single Line Diagram Instrumentation AC System 97 Limerick Drawing E-0164 Sheet 1 Rev. 19, Safeguard Busses Dll thru D14, D21 thru D24 Generator Breakers 4KV 98 Limerick Drawing E-0164 Sheet 3 Rev. 10, Safeguard Busses Dll thru D14 and D21 thru D24 Generator Breakers 4KV 99 Limerick Drawing E-0164 Sheet 5 Rev. 9, Safeguard Busses Dll thru D14 Generator Breakers 4KV 100 Limerick Drawing E-0164 Sheet SA Rev. 1, Schematic Diagram Safeguard Busses D21, 22, 23, 24 Generator Breakers 4KV Unit 2 101 Limerick Drawing E-0169 Sheet 1 Rev. 11, Schematic Diagram -Diesel Generator Protective 102 Limerick Drawing E-0168 Sheet 1 Rev. 6, Schematic Diagram -Safeguard Buses, Protective Relaying 103 Limerick Drawing M-071-00147 Sheet 1 Rev. 21, Schematic Power Chassis Nuclear Exciter/Regulator 104 Limerick Drawing M-071-00065 Sheet lA Rev. 19, Control Schematic Dll Diesel Generator 105 Limerick Drawing M-071-00065 Sheet 6 Rev. 2, Control Schematic D12 Diesel Generator 106 Limerick Drawing M-071-00065 Sheet 12 Rev. 3, Control Schematic D13 Diesel Generator 107 Limerick Drawing M-071-00065 Sheet 18 Rev. 3, Control Schematic D14 Diesel Generator 108 Limerick Drawing M-071-00065 Sheet 24 Rev. 3, Control Schematic D21 Diesel Generator 109 Limerick Drawing M-071-00065 Sheet 30 Rev. 3, Control Schematic D22 Diesel Generator 110 Limerick Drawing M-071-00065 Sheet 36 Rev. 2, Control Schematic D23 Diesel Generator 111 Limerick Drawing M-071-00065 Sheet 42 Rev. 3, Control Schematic D24 Diesel Generator 112 Limerick Drawing M-071-00048 Sheet 1 Rev. 30, Schematic Engine Control Dll Diesel Generator 113 Limerick Drawing M-071-00048 Sheet 2 Rev. 32, Schematic Engine Control Dll Diesel Generator 114 Limerick Drawing M-071-00048 Sheet 3 Rev. 33, Schematic Engine Control Dll Diesel Generator 115 Limerick Drawing M-071-00048 Sheet 6 Rev. 14, Schematic Engine Control D12 Diesel Generator 116 Limerick Drawing M-071-00048 Sheet 7 Rev. 3, Schematic Engine Control D12 Diesel Generator 117 Limerick Drawing M-071-00048 Sheet 8 Rev. 1, Schematic Engine Control D12 Diesel Generator 118 Limerick Drawing M-071-00048 Sheet 11Rev.0, Schematic Engine Control D13 Diesel Generator 119 Limerick Drawing M-071-00048 Sheet 12 Rev. 3, Schematic Engine Control D13 Diesel Generator 120 Limerick Drawing M-071-00048 Sheet 13 Rev. 1, Schematic Engine Control D13 Diesel Generator 121 Limerick Drawing M-071-00048 Sheet 16 Rev. 0, Schematic Engine Control D14 Diesel Generator 122 Limerick Drawing M-071-00048 Sheet 17 Rev. 3, Schematic Engine Control D14 Diesel Generator Page 29of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 123 Limerick Drawing M-071-00048 Sheet 18 Rev. 1, Schematic Engine Control D14 Diesel Generator 124 Limerick Drawing M-071-00048 Sheet 21 Rev. 0, Schematic Engine Control D21 Diesel Generator 125 Limerick Drawing M-071-00048 Sheet 22 Rev. 3, Schematic Engine Control D21 Diesel Generator 126 Limerick Drawing M-071-00048 Sheet 23 Rev. 1, Schematic Engine Control D21 Diesel Generator 127 Limerick Drawing M-071-00048 Sheet 26 Rev. 0, Schematic Engine Control D22 Diesel Generator 128 Limerick Drawing M-071-00048 Sheet 27 Rev. 3, Schematic Engine Control D22 Diesel Generator 129 Limerick Drawing M-071-00048 Sheet 28 Rev. 1, Schematic Engine Control D22 Diesel Generator 130 Limerick Drawing M-071-00048 Sheet 31 Rev. 0, Schematic Engine Control D23 Diesel Generator 131 Limerick Drawing M-071-00048 Sheet 32 Rev. 3, Schematic Engine Control D23 Diesel Generator 132 Limerick Drawing M-071-00048 Sheet 33 Rev. 1, Schematic Engine Control D23 Diesel Generator 133 Limerick Drawing M-071-00048 Sheet 36 Rev. 0, Schematic Engine Control D24 Diesel Generator 134 Limerick Drawing M-071-00048 Sheet 37 Rev. 3, Schematic Engine Control D24 Diesel Generator 135 Limerick Drawing M-071-00048 Sheet 38 Rev. 1, Schematic Engine Control D24 Diesel Generator 136 Limerick Drawing E-017-00012 Sheet 1Rev.11, Diagram -Schematic Arrangement 130 K300 and 400 Chargers 137 Limerick Drawing E-017-00014 Sheet 1 Rev. 9, Diagram -Schematic Arrangement 130 HK75/100F3 Chargers 138 Limerick Drawing E-017-00065 Sheet 1 Rev. 2, High Voltage Shutdown with Time Delay Universal PC Board 139 Limerick Drawing E-0032 Sheet 1 Rev. 64, Single Line Meter and Relay Diagram Uninterruptible AC, RPS, UPS, Computer 140 Limerick Drawing N-OOE-72-00010 Sheet 1Rev.1, Power Stage Wiring 30KVA Inverter Solid State Switch 1AD160 141 Limerick Drawing E-0032 Sheet 2 Rev. 39, Single Line Meter and Relay Diagram Un interruptible AC System 142 Limerick Drawing N-OOE-72-00015 Sheet 1 Rev. 1, Power Stage Wiring 30KVA Inverter Solid State Switch 1BD160 143 Limerick Drawing M-0020 Sheet 6 Rev. 52, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Starting Air System Unit 1) 144 Limerick Drawing M-0020 Sheet 12 Rev. 16, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Starting Air System Unit 2) Page 30of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 145 Limerick Drawing M-0020 Sheet 8 Rev. 23, Piping and Instrument Diagram Fuel and Diesel Oil Storange and Transfer (Combustion Air Intake and Exhaust System Unit 1) 146 Limerick Drawing M-0020 Sheet 14 Rev. 15, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Combustion Air Intake and Exhaust System Unit 2) 147 Limerick Drawing M-0020 Sheet 7 Rev. 53, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Lube Oil System Unit 1) 148 Limerick Drawing M-0020 Sheet 13 Rev. 18, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Lube Oil System Unit 2) 149 Limerick Drawing M-0020 Sheet 3 Rev. 39, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Fuel Oil and Transfer System Unit 1) 150 Limerick Drawing M-0020 Sheet 9 Rev. 17, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Fuel Oil and Transfer System Unit 2) 151 Limerick Drawing M-071-00048 Sheet 5 Rev. 21, Schematic Engine Control Dll Diesel Generator 152 Limerick Drawing M-071-00048 Sheet 10 Rev. 1, Schematic Engine Control D12 Diesel Generator 153 Limerick Drawing M-071-00048 Sheet 15 Rev. 1, Schematic Engine Control D13 Diesel Generator 154 Limerick Drawing M-071-00048 Sheet 20 Rev. 1, Schematic Engine Control D14 Diesel Generator 155 Limerick Drawing M-071-00048 Sheet 25 Rev. 1, Schematic Engine Control D21 Diesel Generator 156 Limerick Drawing M-071-00048 Sheet 30 Rev. 1, Schematic Engine Control D22 Diesel Generator 157 Limerick Drawing M-071-00048 Sheet 35 Rev. 1, Schematic Engine Control 023 Diesel Generator 158 Limerick Drawing M-071-00048 Sheet 40 Rev. 1, Schematic Engine Control 024 Diesel Generator 159 Limerick Drawing M-0020 Sheet 4 Rev. 46, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 1) 160 Limerick Drawing M-0020 Sheet 5 Rev. 44, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 1) 161 Limerick Drawing M-0020 Sheet 10 Rev. 51, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Coling Water System Unit 2) 162 Limerick Drawing M-0020 Sheet 11 Rev. 8, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 2) 163 Limerick Drawing M-0011Sheet1 Rev. 86, Piping and Instrument Diagram Emergency Service Water (Unit 1, Unit 2, and Common) 164 Limerick Drawing E-0321 Sheet 2 Rev. 19, Schematic Diagram Emergency Service Water Pumps 165 Limerick Drawing E-0321Sheet3 Rev. 19, Schematic Diagram Emergency Service Water Pumps 166 Limerick Drawing E-0321Sheet5 Rev. 17, Schematic Diagram Emergency Service Water Pumps Page 31of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 167 Limerick Drawing M-0081Sheet1 Rev. 31, Piping and Instrument Diagram Miscellaneous Structures HVAC 168 Limerick Drawing M-0081 Sheet 3 Rev. 15, Piping and Instrument Diagram Miscellaneous Structures HVAC (Unit 2 and Common) 169 Limerick Drawing E-0490 Sheet 1 Rev. 16, Schematic Diagram Diesel Generator Ventilation Air Exhaust Fans and Auxiliary Control Units 1 and 2 170 Limerick Drawing E-0490 Sheet 2 Rev. 10, Schematic Diagram Diesel Generator Ventilation Air Exhaust Fans and Auxiliary Control Units 1 and 2 171 Limerick Drawing E-0163 Sheet 1 Rev. 18, Schematic Diagram -Safeguard Buses -Safeguard Load Center 172 Limerick Drawing E-0163 Sheet 2 Rev. 3, Schematic Diagram -Safeguard Buses -Safeguard Load Center 173 Limerick Drawing E-0162 Sheet 1Rev.13, Schematic Diagram-Safeguard Buses -Dl44 and D244 Page 32of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 A Representative Sample Component Evaluations The following sample calculation is extracted from Reference
Note;            . -,. Evaluated in1Ref. ~18)
[17). Notes: 1. Reference citations within the sample calculation are per the Ref. [17) reference section shown on the following page. 2. This sample calculation contains evaluations of sample high-frequency-sensitive components per the methodologies of both the EPRI high-frequency guidance [8) and the flexible coping strategies guidance document NEI 12-06 [16). Page 33 of 11 O St""""""1&Aisociates S&A Cale. No.: 15C4345-CAL-001, Rev. 2 Title: High Frequency Functional Confirmation and Fragility Evaluation of Components 6 REFERENCES
P&ID DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-108        HV-052-108    M-0052      1     Only needed if HV-1F006B fails to Section 2.2 of this report.
: 1. Codes. Guidance.
be closed HV-1F006A      HV-052-lFOOGA  M-0052      1                 CHECK VALVE                              Yes*
and Standards 15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Sheet 9 of 20 Prepared:
DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-1F005      HV-052-1F005    M-0052      1     Only needed if HV-1F006A fails to Section 2.2 of this report.
FG Date: 10/27 /16 Reviewed:
be closed Normally Open- Need to check if HV-1F002      HV-055-1F002    M-0055      1                                                         Yes*
MD Date: 10/27/16 1.1. EPRI 3002004396.
there is a signal to close Would only be a potential Leak      No - See notes and discussion in HV-1F003      HV-055-1F003    M-0055      1 Path if HV-1F002 fails to be closed      Section 2.2 of this report.
" High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation
HV-2F001      HV-041-2F001    M-0041      4                                                        Yes*
." July 2015. 1.2. EPRI 3002002997. "High Frequency Program: High Frequency Testing Summary." September 2014. 1.3. Not Used 1.4. NEI 12-06, Appendix H, Rev. 2, "Diverse and Flexible Coping Strategies (FLEX) Implementation Guide." 1.5. IEEE 344-1975 "IEEE Recommended Practices for Seismic Qualification of Class lE Equipment for Nuclear Power Generating Stations" 1.6. SQUG GIP 3A, "Generic Implementation Procedure (GIP) for Seismic Verification of Nuclear Plant Equipment", December 2001 1.7. EPRI NP-7147-SL, "Seismic Ruggedness of Relays", August 1991 1.8. EPRI NP-7147-SL, SQUG Advisory 2004-02. "Relay GERS Corrections", September 10, 2004 1.9. EPRI NP-7147-SLV2, Addendum 1, "Seismic Ruggedness of Relays", September 1993 1.10. ANSI/IEEE C37.98-1987, "An American National Standard IEEE Standard Seismic Testing of Relays." January 15, 1988 1.11. EPRI NP-6041-SL , Rev. 1, "A Methodology for Assessment of Nuclear Power Plant Seismic Margin", August 1991 1.12. EPRI NP-7147-SLV2, Addendum 2, "Seismic Ruggedness of Relays", April 1995 2. Nuclear Regulatory Commission Documents
HV-2F002      HV-041-2F002    M-0041      4                                                        Yes*
NORMALLY OPEN TO MAIN STEAM LINE C. NOT A LEAK PATH HV-2F005      HV-041-2F005    M-0041      4                                                           No (No Need to be included- Line C is isolated)
Page 103 of 11 O


===2.1. Limerick===
1SC4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE 10., on, I
Generating Station Units 1 & 2 Seismic Hazard and Screening Report, Rev. 0, NRC Docket No. STN 50-352 & STN 50-353, Correspondence No. RS-14-069
PIMS ID        P&ID      SHEET  :              Notes              I    Evaluated in Ref. [18)
: 3. Station Documents
P&ID      I DOWN STREAM CHECK VALVE HV-HV-2F011A        HV-041-2F011A    M-0041      4      2F010A will provide Boundary (No                No Need to be included)
SIMPLE CHECK VALVE {No Need to 2F010A          041-2F010A    M-0041      4                                                      No be included)
DOWN STREAM OF CHECK VALVE HV-2F074A        HV-041-2F074A    M-0041      4                                                      No (No Need to be included)
DOWN STREAM CHECK VALVE HV-HV-2F011B        HV-041-2F011B    M-0041      4      2F010B will provide Boundary (No                No Need to be included)
SIMPLE CHECK VALVE (No Need to 2F010B          041-2F010B    M-0041      4                                                      No be included)
DOWN STREAM OF CHECK VALVE HV-2F074B        HV-041-2F074B    M-0041      4                                                      No (No Need to be included)
PSV-2F013A      PSV-041-2F013A  M-0041      5                      SRV                            Yes*
PSV-2F013B      PSV-041-2F013 B  M-0041      5                      SRV                            Yes*
PSV-2F013C      PSV-041-2F013C  M-0041      5                      SRV                            Yes*
Page 104of110


===3.1. Limerick===
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177
Drawing C-0409, Rev. 33, "Control Room Area, Foundations, Wall Elevations Area 8" 3.2. General Electric Report GE-101, Rev. 2, "GE Dynamic Qualification Report for Class lE Control Room Panels" 3.3. General Electric Report GE-201 , Rev. 2, "GE Dynamic Qualification Report for Class lE Control Room Panels" 3.4. Limerick Drawing C-0682, Rev. 11, "Diesel Generator Building Unit 2 Wall Elevation
[
& Sections" 3.5. Limerick Report D-0014, Rev. 7, "Dynamic Qualification Book", Volumes 1-3. 3.6. Limerick Report D-0007, Rev. 10, "Dynamic Qualification Book", Volumes 1-2. 3.7. Not Used 3.8. Limerick Report D-0015, Rev. 12 , "Dynamic Qualification Book", Volumes 1-4. 4. S&A Documents 4.1. 15C4345-RPT-001, Rev. 3, "Selection of Relays and Switches for High Frequency Seismic Evaluation." 5. Other Documents 5.1. TE Connectivity, Qualification Test Report 501-529, "Nuclear Environmental Qualification Test Report on Agastat EGP, EML and ETR Control Relays by Control Products Division, Amerace Corporation" 5.2. GE Multilin IAC Time-Overcurrent Brochure, "Time-overcurrent protection of AC circuits and apparatus." (See Attachment E) 5.3. Agastat Nuclear Qualified Control Relays, dated 4/24/2002 "Series EGP/EML/ETR" (See Attachment F) Page 34 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2 Title: High Frequency Functional Confirmation and Fragility Evaluation of Components Prepared: FG Reviewed: MD Sheet 12 of 20 Date: 10/27 /16 Date: 10/27 /16 Stevenson
Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I s.;~~J -~=                             l VAL\lE IDmi!
& As.scxiates 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand Calculate the high-frequency seismic demand on the components per the methodology from Ref. 1.1. Sample calculations for the high-frequency seismic demand of components PIS-050-1 N653 located in Unit 1 and E51A-K10 located in Unit 1 are presented below. A table that calculates the high-frequency seismic demand for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A , Table A-2 of this calculation. 8.2.1 Horizontal Seismic Demand The horizontal site-specific GMRS for Limerick is per Ref. 2.1. GMRS data can be found in Attachment B of this calculation. Determine the peak acceleration of the horizontal GMRS between 15 Hz and 40 Hz. Peak acceleration of horizontal GMRS between 15 Hz and 40 Hz (Ref. 2.1; see Attachment B of this calculation)
* I
:
* PIMS[        P&ID                          Notes                      Evaluated in Ref. r[l8]
:= 0.381 g (at 15 Hz) Calculate the horizontal in-structure amplification factor based on the distance between the bottom of the foundation elevation and the subject floor elevation. Bottom of Deepest Foundation Elevation: (Ref. 2.1, Table 2.3.1-1, Note C) Component Floor Elevation (See Table A-1 ): Elfound := 174*ft Elcomp :-289*ft Components PIS-050-1 N653 and E51A-K10 are both located in the Control Enclosure building at elevation 289'. Distance Between Component Floor and Foundation Elevation:
P&ID
hcomp := ELcomp -Elfound -115.00 *ft Page 35 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2 Title: High Frequency Functional Confirmation and Fragility Evaluation of Components Prepared: FG Reviewed:
                                -~
MD Sheet 13 of 20 Date: 10/27 /16 Date: 10/27/16 Stevenson
PSV-2F013D    PSV-041-2F013D  M-0041      5                  SRV                                Yes*
& A5scc:iates 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd) B.2.1 Horizontal Seismic Demand (cont'd) Work the distance between the component floor and foundation with Ref. 1.1, Fig. 4-3 to calculate the horizontal in-structure amplification factor. Slope of Amplification Factor Line , Oft < hcomp < 4Dft Intercept of Amplification Factor Line , Oft < hcomp < 40ft 2.1-1.2 1 mh := = 0.0225*-40ft -Oft ft Horizontal In-Structure Amplification Factor: AF SH(hcomp)
PSV-2F013E    PSV-041-2F013E  M-0041      5                  SRV                                Yes*
:= I ( mh
PSV-2F013F    PSV-041-2F013F  M-0041      5                  SRV                                Yes*
* hcomp + bh) if hcomp s 40ft 2.1 otherwise Calculate the horizontal in-cabinet amplification factor based on the type of cabinet that contains the subject component.
PSV-2F013G    PSV-041-2F013G  M-0041      5                  SRV                                Yes*
Type of Cabinet (per Ref. 3.2 and 3.3) (enter "MCC", "Switchgear", "Control Cabinet", or "Rigid"):
PSV-2F013H    PSV-041-2F013H  M-0041      5                  SRV                                Yes*
Horizontal In-Cabinet Amplification Factor (Ref. 1.1, p. 4-13): cab := "Control Cabinet" AFc.h(cab) := 3.6 if 7.2 if 4.5 if 1.0 if AFc.h(cab) = 4.5 cab= "MCC" cab = "Switchgear" cab = "Control Cabinet" cab = "Rigid" Multiply the peak horizontal GMRS acceleration between by the horizontal in-structure and in-cabinet amplification factors to determine the in-cabinet response spectrum demand on the components. Horizontal In-Cabinet Response Spectrum (Ref. 1.1 , p. 4-12 , Eq. 4-1a): Note that the horizontal seismic demand is the same for both components PIS-050-1 N653 and E51A-K10.
PSV-2F013J    PSV-041-2F013J  M-0041      5                  SRV                                Yes*
Page 36 of 110 S&A Cale. No.: 1SC4345-CAL-001, Rev. 2 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA Title: High Frequency Functional Confirmation and Fragility Evaluation of Components Prepared:
PSV-2F013K    PSV-041-2F013K  M-0041      5                  SRV                                Yes*
FG Reviewed:
PSV-2F013L    PSV-041-2F013L  M-0041      5                  SRV                                Yes*
MD Sheet 14 of 20 Date: 10/27 /16 Date: 10/27/16 Stevenson
PSV-041-PSV-2F013M                      M-0041      5                  SRV                                Yes*
& As.scciiltes 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd) B.2.2 Vertical Seismic Demand Determine the peak acceleration of the horizontal GMRS between 15 Hz and 40 Hz. Peak Acceleration of Horizontal GMRS Between 15 Hz and 40 Hz (See Sect. 8. 2.1 of this Calculation)
2F013M PSV-2F0135    PSV-041-2F0135  M-0041      5                  SRV                                Yes*
-0.381 .g (at 15 Hz) Obtain the peak ground acceleration (PGA) of the horizontal GMRS from Ref. 2.1 (See Attachment B of this calculation).
PSV-2F013N    PSV-041-2F013N    M-0041      5                  SRV                                Yes*
Peak Ground Acceleration (GMRS): PGAGMRS : "" 0.193g Calculate the shear wave velocity traveling from a depth of 30m to the surface of the site 01 530) from Ref. 1.1 and Attachment C. Shear Wave Velocity:
HV-F022A      HV-041-2F022A    M-0041      5                                                      Yes*
where, di: Thickness of the layer (ft) V si: Shear wave velocity of the layer (ft/s) (30m) Vs30 = 1:( di.) VSI Per Attachment C, the sum of thickness of the layer over shear wave velocity of the layer is 0.0288 sec. Shear Wave Velocity:
Page 105of110
30m ft v := = 3418*-s3o 0.028Bsec sec Page 37 of 110 S&A Cale. No.: 15C4345-CAL-001, Rev. 2 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA Title: High Frequency Functional Confirmation and Fragility Evaluation of Components Prepared: FG Reviewed:
MD Sheet 15 of 20 Date: 10/27/16 Date: 10/27 /16 Stevenson
& Associates 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd) 8.2.2 Vertical Seismic Demand (cont'd) Work the PGA and shear wave velocity with Ref. 1.1, Table 3-1 to determine the soil class of the site. Based on the PGA of 0.1939 and shear wave velocity of 3418ft/sec at Limerick, the site soil class is B-Hard. Work the site soil class with Ref. 1.1, Table 3-2 to determine the mean vertical vs. horizontal GMRS ratios (V/H) at each spectral frequency. Multiply the V/H ratio at each frequency between 15Hz and 40Hz by the corresponding horizontal GMRS acceleration at each frequency between 15Hz and 40Hz to calculate the vertical GMRS. See Attachment B for a table that calculates the vertical GMRS (equal to (V/H) x horizontal GMRS) between 15Hz and 40Hz. Determine the peak acceleration of the vertical GMRS (SAvGMRs) between frequencies of 15Hz and 40Hz. (By inspection of Attachment B, the SAvGMRs occurs at 15Hz.) V/H Ratio at 15Hz (See Attachment B of this calculation)
: Horizontal GMRS at Frequency of Peak Vertical GMRS (at 15Hz) (See Attachment B of this calculation)
: Peak Acceleration of Vertical GMRS Between 15 Hz and 40 Hz: VH := 0.68 HGMRS :-0.3819 SAvGMRS := VH*HGMRS-= 0.259*9 (at 15 Hz) A plot of horizontal and vertical GMRS is provided in Attachment B of this calculation. Page 38 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA Stevenson
& As.soc:iates S&A Cale. No.: 15C4345-CAL-001 , Rev. 2 Title: High Frequency Functional Confirmation and Fragility Evaluation of Components 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd) 8.2.2 Vertical Seismic Demand (cont'd) Prepared: FG Reviewed: MD Sheet 16 of 20 Date: 10/27 /16 Date: 10/27 /16 Calculate the vertical in-structure amplification factor based on the distance between the plant foundation elevation and the subject floor elevation.
Distance Between Component Floor and Foundation (See Sect. 8.2.1 of this Calculation)
: hcomp = 115.QQ.ft Work the distance between the component floor and foundation with Ref. 1.1 , Fig. 4-4 to calculate the vertical in-structure amplification factor. Slope of Amplification Factor Line: 2.7 1.0 1 -0.017*-1 OD ft -Oft ft Intercept of Amplification Factor Line: Vertical In-Structure Amplification Factor: AF SV :-mv* hcomp + bv = 2. 96 Per Ref. 1.1, the vertical in-cabinet amplification factor is 4. 7 regardless of cabinet type. Vertical In-Cabinet Amplification Factor: Multiply the peak vertical GMRS acceleration between by the vertical in-structure and in-cabinet amplification factors to determine the in-cabinet response spectrum demand on the component.
Vertical In-Cabinet Response Spectrum (Ref. 1.1 , p. 4-12, Eq. 4-1b): ICRSc.v :: AFsv*AFc.v*SAvGMRS = 3.60*g Note that the vertical seismic demand is the same for both components PIS-050-1 N653 and E51A-K1 DA. Page 39 of 110 S&A Cale. No.: 15C4345-CAL-001, Rev. 2 15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 SA Title: High Frequency Functional Confirmation and Fragility Evaluation of Components Prepared: FG Reviewed:
MD Sheet 17 of 20 Date: 10/27 /16 Date: 10/27 /16 Steven.son
& Associates 8 ANALYSIS (cont'd) 8.3 High-Frequency Seismic Capacity A sample calculation for the high-frequency seismic capacity of components PIS-050-1 N653 and E51A-K10 located in Unit 1 is presented here. A table that calculates the high-frequency seismic capacities for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation.


====8.3.1 Seismic====
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 VA~VE Iii> on P&ID r Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation 0
Test Capacity The high frequency seismic capacity of a component can be determined from the EPRI High Frequency Testing Program (Ref. 1.2) or other broad banded low frequency capacity data such as the Generic Equipment Ruggedness Spectra (GERS) or other qualification reports. The model for component PIS-050-1 N653, a Rosemount 510DU2 trip unit per Table A-1 , was not tested as part of the Ref. 1.2 high-frequency testing program. Attachment A (Group 1) provides a seismic capacity calculation for Rosemount 510DU2 trip unit based on Limerick Seismic Report GE-101 (Ref. 3.20). The seismic capacity was calculated in Attachment A to be 11. 62g for component Pl S-050-1 N653. The model for component E51A-K10 is an Agastat EGPB002 relay per Table A-1. Per Ref. 5.1, Page 2, Agastat EGP and GP series relays are the same relays and the "E" (nuclear safety related) designator was added to the front. Per Ref. 1.12, Page 2-4 , the lowest capacity of Agastat Model GP relay 5.0g. Note that the capacity of Agastat GP relay provided in Ref. 1.12 , Page 2-4 and 2-6 is based on additional verification test level only (this capacity is not the GERS capacity, but a qualification test capacity). Seismic Test Capacity (SA*): 8.3.2 Effective Spectral Test Capacity (11.62) SA':= g 5.00 (PIS-050-1 N653) E51A-K10 Since a qualification report was used as the capacity source for both components , there are no spectral acceleration increases and the effective spectral test capacity is equal to the seismic test capacity. Effective Spectral Test Capacity (Ref. 1.1 , p. 4-16): *-(SA'1 J-(11.62)
PIMS ;D~  ]  P&ID I SHEET  [
SAT.--*g SA'2 5.00 ( PIS-050-1 N653) E51A-K10 Page 40 of 110 SA Stevenson
I -,=---~-:~**                    1 Evaluated in Ref. 1[l8]
& Associates S&A Cale. No.: 1SC4345-CAL-001, Rev. 2 Title: High Frequency Functional Confirmation and Fragility Evaluation of Components 8 ANALYSIS (cont'd) 8.3 High-Frequency Seismic Capacity (cont'd) 8.3.3 Seismic Capacity Knockdown Factor 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Prepared:
HV-F028A      HV-041-2F028A  M-0041      5                                                        Yes*
FG Reviewed:
HV-F022B      HV-041-2F022B  M-0041      5                                                        Yes*
MD Sheet 18 of 20 Date: 10/27 /16 Date: 10/27 /16 Determine the seismic capacity knockdown factor for the subject component based on the type of testing used to determine the seismic capacity of the component.
HV-F028B      HV-041-2F028B  M-0041      5                                                        Yes*
Using Table 4-2 of Ref. 1.1 and the capacity sources from Section 8.3.1 above, the knockdown factors are chosen as: Seismic Capacity Knockdown Factor: 8.3.4 Seismic Testing Single-Axis Correction Factor F := (1.20) k 1.20 (PIS-050-1 N653) E51A-K10 Determine the seismic testing single-axis correction factor of the subject component, which is based on whether the equipment housing to which the component is mounted has well-separated horizontal and vertical motion or not. Per Ref. 1.1, pp. 4-18, conservatively take the FMs value as 1.0. Single-Axis Correction Factor (Ref. 1.1, pp. 4-17 to 4-18): FMS := 1.0 Page 41 of 110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Steven.son
HV-F022C      HV-041-2F022C  M-0041      5                                                        Yes*
& As.scciates S&A Cale. No.: 15C4345-CAL-001, Rev. 2 Title: High Frequency Functional Confirmation and Fragility Evaluation of Components 8 ANALYSIS (cont'd) Prepared: FG Reviewed:
HV-F028C    HV-041-2F028C    M-0041      5                                                        Yes*
MD 8.3 High-Frequency Seismic Capacity for Ref. 1.1 Components (cont'd) 8.3.5 Effective Wide-Band Component Capacity Acceleration Calculate the effective wide-band component capacity acceleration per Ref. 1.1, Eq. 4-5. Effective Wide-Band Component Capacity Acceleration (Ref. 1. 1, Eq. 4-5): [SAT) (9.683) TRS :=--*FMS = *g Fk 4.167 8.4 High-Frequency Seismic Capacity for Ref. 1.4, Appendix H Components
HV-F022D    HV-041-2F022D    M-0041      5                                                        Yes*
HV-F028D    HV-041-2F028D    M-0041      5                                                        Yes*
HV-C-F020    HV-C-041-2F020  M-0041      5                                                        Yes*
HV-2F016      HV-041-2F016    M-0041      5        Normally Closed Drain Line                    Yes*
Normally Closed Drain Line would No - See notes and discussion in HV-2F019      HV-041-2F019    M-0041      5       only be a Leak Path if HV-2F016 Section 2.2 of this report.
Opens Normally Open- Need to check if HV-2F105      HV-044-2F105    M-0044      3                                                        Yes*
there is a signal to close Page 106 of 110


====8.4.1 Effective====
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 8-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation 1
VALVJ ID on I                  I PIMSID          P&ID    SHEET                  Notes                    Evaluated in Ref. 1[1.8]
P&ID I
Would only be a Leak Path if HV-    No - See notes and discussion in HV-2F001      HV-044-2F001    M-0044      3 2F105 fails to be closed        Section 2.2 of this report.
Would only be a Leak Path if HV-    No - See notes and discussion in HV-2F004      HV-044-2F004    M-0044      3 2F105 fails to be closed        Section 2.2 of this report.
Normally Open- Need to check if HV-2F100      HV-044-2F100    M-0044      3                                                        Yes*
there is a signal to close Normally Open- Need to check if HV-2F007      HV-049-2F007    M-0049      2                                                        Yes*
there is a signal to close Would only be a Leak Path if HV-    No - See notes and discussion in HV-2F008      HV-049-2F008    M-0049      2 2F107 fails to be closed          Section 2.2 of this report.
Per the Plant this is the Containment Spray Valves and HV-2F021A      HV-051-2F021A    M-0051      5                                                  No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-2F016A      HV-051-2F016A    M-0051      5                                                  No - See Note does not communicate with the Reactor HV-2F041C      HV-051-2F041C    M-0051      5                CHECK VALVE                            Yes*
Page 107of110


Wide-Band Component Capacity Acceleration Sheet 19 of 20 Date: 10/27/16 Date: 10/27 /16 (PIS-050-1N653) E51A-K10 Per a review of the capacity generation methodologies of Ref. 1.1 and Ref. 1.4 , App. H, Section H.5 , the capacity of a Ref. 1.4 component is equal to the Ref. 1.1 effective wide-band component capacity multiplied by a factor accounting for the difference between a 1 % probability of failure (C 1 %* Ref. 1.1) and a 10% probability of failure (C 10'A,. Ref. 1.4). Per Ref. 1.4, App. H , Table H.1, use the C 10% vs. C 1% ratio from the Realistic Lower Bound Case for components. c10',, vs. c,% ratio Effective wide-band component capacity acceleration (Ref. 1.4, App. H, Sect. H.5) c 10 :=-1.36 (13.169) TRS1 4 := TRS*C10-' *g . 5.667 (PIS-050-1N653) E51A-K10 Page 42 of 110 SA Stevenson
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE ID on 1 PIMSW)         P&ID     SHEET                  Notes                    Evaluated in Ref. [18]
& Associates S&A Cale. No.: 15C4345-CAL-001, Rev. 2 Title: High Frequency Functional Confirmation and Fragility Evaluation of Components 8 ANALYSIS (cont'd) 8.5 Component (Ref. 1.1) High-Frequency Margin 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Prepared: FG Reviewed:
P&ID I
MD Sheet 20 of 20 Date: 10/27/16 Date: 10/27/16 Calculate the high-frequency seismic margin for components per Ref. 1.1, Eq. 4-6. A sample calculation for the high-frequency seismic demand of components PIS-050-1 N653 and E51A-K10 is presented here. A table that calculates the high-frequency seismic margin for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation. TRS (2.689) > 1.0, O.K. (PIS-050-1N653)
No - See notes and discussion in HV-2F017C    HV-051-2F017C    M-0051      5     DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
Horizontal seismic margin (Ref. 1.1, Eq. 4-6): ICRSc.h "' 1.157 > 1.0, O.K. E51A-K10 TRS (2.691) > 1.0, O.K. ( PIS-050-1 N653) Vertical seismic margin (Ref. 1.1, Eq. 4-6): ICRSc.v = 1.158 > 1.0, O.K. E51A-K10 Both the horizontal and vertical seismic margins for PIS-050-1 N653 and E51A-K10 are greater than 1.00; indicating that these components are adequate for high frequency seismic spectral ground motion for its Ref. 1.1 functions. 8.6 Component (Ref. 1.4) High-Frequency Margin Calculate the high-frequency seismic margin for Ref. 1.4 components per Ref. 1.1 , Eq. 4-6. A sample calculation for the high-frequency seismic demand of component components PIS-050-1 N653 and E51A-K10 is presented here. A table that calculates the high-frequency seismic margin for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation. Horizontal seismic margin (Ref. 1.1, Eq. 4-6): * = TRS1 4 (3.658) ICRSc.h 1.574 Vertical seismic margin (Ref. 1.1, Eq. 4-6): TRS1 .4 (3.660) ICRSc.v = 1.575 > 1.0, O.K. > 1.0, O.K. > 1.0, O.K. > 1.0, O.K. (PIS-050-1 N653) E51A-K10 ( PIS-050-1 N653) E51A-K10 Both the horizontal and vertical seismic margins for PIS-050-1 N653 and E51A-K10 are greater than 1.00; therefore , these components are adequate for high-frequency seismic spectral ground motion for its Ref. 1.4 functions.
HV-2F041A    HV-051-2F041A    M-0051      5               CHECK VALVE                            Yes*
Page 43 of 110 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 B Components Identified for High Frequency Confirmation Table B-1: Components Identified for High Frequency Confirmation
No - See notes and discussion in HV-2F017A    HV-051-2F017A    M-0051      5      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
-. -Component Enclosure Component Evaluation
HV-2F050A    HV-051-2F050A    M-0051      5                CHECK VALVE                            Yes*
-Floor No. Unit Manufacturer Model No. Building Elev. {ft) Basis for Evaluation I D ' Type System Function ID Type Capacity Result ' PIS-049-Control Core RCIC Steam Pressure Rosemount 510DU1 10-C617 Control Control 289 Qualification Cap> Dem 1 1 1N658A Relay Cooling Indicating Switch Cab. Enclosure Test 2 1 PIS-049-Control Core RCIC Steam Pressure Rosemount 710DUOIT 10-C640 Control Control 289 Qualification Cap> Dem 1N658C Relay Cooling Indicating Switch Cab. Enclosure Test PIS-049-Control Core RCIC Steam Pressure 510DU1 10-C617 Control Control 289 Qualification 3 1 1N658E Relay Cooling Indicating Switch Rosemount Cab. Enclosure Test Cap> Dem PIS-049-Control Core RCIC Steam Pressure 510DU1 10-C640 Control Control 289 Qualification 4 1 1N658G Relay Cooling Indicating Switch Rosemount Cab. Enclosure Test Cap> Dem 5 1 PIS-050-Control Core RCIC Pump Suction Rosemount 510DU2 10-C617 Control Control 289 Qualification Cap> Dem 1N653 Relay Cooling Header Cab. Enclosure Test 6 1 PIS-050-Control Core RCIC Turbine Exhaust Rosemount 510DU1 10-C617 Control Control 289 Qualification 1N655A Relay Cooling Line Vent Cab. Enclosure Test Cap> Dem PIS-050-Control Core RCIC Turbine Exhaust 510DU1 10-C640 Control Control Qualification 7 1 1N655C Relay Cooling Line Vent Rosemount Cab. Enclosure 289 Test Cap> Dem 8 1 PIS-050-Control Core RCIC Turbine Exhaust Rosemount 510DU1 10-C617 Control Control 289 Qualification Cap> Dem 1N655E Relay Cooling Line Vent Cab. Enclosure Test PIS-050-Control Core RCIC Turbine Exhaust 510DU1 10-C640 Control Control 289 Qualification 9 1 1N655G Relay Cooling Line Vent Rosemount Cab. Enclosure Test Cap>Dem 10 1 PIS-050-Control Core RCIC Pump Turbine 510DU2 10-C617 Control Control 289 Qualification 1N656A Relay Cooling Exhaust Rosemount Cab. Enclosure Test Cap> Dem 11 1 PIS-050-Control Core RCIC Pump Turbine Rosemount 510DU2 10-C617 Control Control 289 Qualification 1N656E Relay Cooling Exhaust Cab. Enclosure Test Cap> Dem 12 2 PIS-049-Control Core RCIC Steam Pressure 510DU1 20-C617 Control Control 289 Qualification 2N658A Relay Cooling Indicating Switch Rosemount Cab. Enclosure Test Cap> Dem 13 2 PIS-049-Control Core RCIC Steam Pressure Rosemount 710DUOIT 20-C640 Control Control 289 Qualification 2N658C Relay Cooling Indicating Switch Cab. Enclosure Test Cap> Dem 14 2 PIS-049-Control Core RCIC Steam Pressure Rosemount 510DU1 20-C617 Control Control 289 Qualification Cap> Dem 2N658E Relay Cooling Indicating Switch Cab. Enclosure Test Page 44 of 110 I No. I 'Type_] 1 10 2 PIS-049-Control 15 2N658G Relay PIS-050-Control 16 2 2N653 Relay PIS-OSO-Control 17 2 2N655A Relay PIS-050-Control 18 2 2N655C Relay PIS-050-Control 19 2 2N655E Relay 2 PIS-050-Control 20 2N655G Relay 2 PIS-050-Control 21 2N656A Relay PIS-050-Control 22 2 2N656E Relay Control 23 1 E51A-K10 Relay Control 24 1 E51A-K11A Relay Control 25 1 E51A-K11C Relay Control 26 1 E51A-K12A Relay 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Floor Component Evaluation I
No - See notes and discussion in HV-2F015A    HV-051-2F015A    M-0051      5      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
J Model No. Elev. (ft) 'Basis for Evaluation Type CaDacltv Result Core RCIC Steam Pressure Rosemount 710DUOTI 20-C640 Control Control 289 Qualification Cap> Dem Cooling Indicating Switch Cab. Enclosure Test Core RCIC Pump Suction 710DUOTI 20-C617 Control Control 289 Qualification Cap> Dem Rosemount Cooling Header Cab. Enclosure Test Core RCIC Turbine Exhaust Rosemount 510DU1 20-C617 Control Control 289 Qualification Cap> Dem Cooling Line Vent Cab. Enclosure Test Core RCIC Turbine Exhaust 710DUOTI 20-C640 Control Control 289 Qualification Cap> Dem Cooling Line Vent Rosemount Cab. Enclosure Test Core RCIC Turbine Exhaust 710DUOTI 20-C617 Control Control 289 Qualification Cap> Dem Cooling Line Vent Rosemount Cab. Enclosure Test Core RCIC Turbine Exhaust Rosemount 510DU2 20-C640 Control Control 289 Qualification Cap> Dem Cooling Line Vent Cab_ Enclosure Test Core RCIC Pump Turbine Rosemount 710DUOTI 20-C617 Control Control 289 Qualification Cap> Dem Cooling Exhaust Cab. Enclosure Test Core RCIC Pump Turbine 710DUOTI 20-C617 Control Control 289 Qualification Cap> Dem Cooling Exhaust Rosemount Cab. Enclosure Test RCIC Pump Suction Core Pressure Relay Control Control Qualification Cooling Energize on Pressure Agastat EGPB002 10-C621 Cab. Enclosure 289 Test Cap> Dem On Vacuum Less than Set-point RCIC Relay-Energize Core on Turbine Control Control Qualification Cooling Diaphragm Exhaust Agastat EGPB002 10-C621 Cab. Enclosu re 289 Test Cap> Dem Pressure Above Set-point RCIC Relay -Energize Core On Turbine Control Control Qualification Cooling Diaphragm Exhaust Agastat EGPB002 10-C640 Cab. Enclosure 289 Test Cap> Dem Pressure Above Set-Point RCIC RELAY-Core Energize on Turbine Control Control Qualification Cooling Diaphragm Exhaust Agastat EGPB002 10-C621 Cab. Enclosure 289 Test Cap> Dem Pressure Above Set-point Page 45 of 110 No. ' Unit " El [ ID II Type 27 1 E51A-K12C Control Relay 28 1 E51A-K13 Control Relay 29 1 E51A-K14 Contro l Relay 30 1 E51A-K16A Control Relay E51A-K16C Control 31 1 Relay Control 32 1 E51A-K17A Relay 33 1 E51A-K17C Control Relay 34 1 E51A-K28 Control Relay 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
HV-2F008    HV-051-2F008    M-0051      5                                                        Yes*
-'Enclosure Building] Component
Per the Plant this is the Containment Spray Valves and HV-2F021B    HV-M51-2F021B    M-0051      7                                                  No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-2F016B    HV-051-2F016B    M-0051      7                                                  No - See Note does not communicate with the Reactor HV-2F041D    HV-051-2F041D    M-0051      7                CHECK VALVE                             Yes*
-' Floor J Component Evaluation
Page 108 of 110
!!
i ModelNo.1 Elev. {ft) Basis for Evaluation ID Capacity Result RCIC Relay -Energize Core on Turbine Control Control Qualification Cooling Diaphragm Exhaust Agastat EGPB002 10-C640 Cab. Enclosure 289 Test Cap> Dem Pressure Above Set-Point RCIC Relay-Core Energ i zes On Turbine Agastat EGPB0 0 2 10-C621 Control Control 289 Qualification Cap> Dem Cooling Exhau s t Pressur e Cab. Enclosure Test Above Set-point RCIC Relay-Core Energizes On Turbine Agastat EGPB0 0 2 10-C621 Control Control 289 Qualification Cap> Dem Cooling Exhau s t Pressure Cab. Enclosure Test Abov e Set-Po i nt RCIC R e lay-Core Energ i zes On Steam Agastat EGPB002 10-C621 Control Control 289 Qualificat i on Cap> Dem Cooling Line P r essure Below Cab. Enclosure Test Set-p oi nt RCIC Re lay-Core Energ i zes On Steam Agastat EGPB0 0 2 10-C640 Control Control 289 Qualification Cap> Dem Cooling Lin e Pr e ssure Be l ow Cab. Enclosure Test Set-P oi nt RCIC Re lay-Core Energ iz es On Steam Agastat EGPB0 0 2 10-C621 Control Control 289 Qualification Cooling Line Pressure Below Cab. E nclosure Test Cap> Dem Set-p oi nt RCIC R e lay-Core Energ i zes On Steam Agastat EGPB0 0 2 10-C640 Control Control 289 Qualification Cap>Dem Cooling Line Pressure Below Cab. Enclosure Test Set-Po i nt Core RCIC Turbine Trip Agastat EGPD002 10-C621 Control Control 289 Qualification Cap> Dem Cooling Auxiliary Relay Cab. Enclosure Test Page 46 of 110 I No., [=ro l [_rvpe:! 35 1 E51A-K30A Control Relay 36 1 ES1A-K30C Control Relay 37 1 E51A-K31A Control Relay 38 1 ES1A-K31C Control Relay 39 1 E51A-K67C Control Relay Control 40 2 ESlA-KlO Relay Co n trol 41 2 ESlA-KllA Relay Control 42 2 ESlA-KllC Relay 15C4345-RPT-002 , Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
<l omponent En c losure
! F.loor Component Evaluation I Function x J l Model No. l;lev. (ft) Basis for Evaluation capacity Resu l t Steam Leak Detection Relay Core (RCIC Isolation Signal Agastat EGPD002 10-C621 Control Control 289 Qualification C a p> Dem Cooling Manual Isolation Cab. Enclosure Test Relay-Valve ESl-F008) RCIC DIV 3 Isolation Core Signal and Steam Agastat EGPD002 10-C640 Control Control 289 Qualification Cooling line Detection Relay Cab. Enclosure Test Cap> Dem (ES1-F007)
RCIC Isolation Signal Core Manual Isolation Agastat EGPD002 10-C621 Control Control Qualification Cooling Relay -Valve ESl-Cab. Enclosure 289 Test Cap> Dem F008 RCIC Iso lation Signal Core Manual Isolation A g a sta t EGPD002 Control Control Qualification Cooling Relay-Valve ESl-10-C640 Cab. Enclosure 289 Test Cap> Dem F008 Core RCIC DIV 3 Isolation Agastat EGPD002 10-C640 Control Control Qualification Cooling Signal Relay Enclosure 289 Cap> Dem Cab. Test RCIC Pump Suction Core Pressure Relay -Control Control Qualification Energize on Pressure Agastat EGPB003 20-C621 289 Cap> Dem Cooling on Vacuum Less than Cab. Enclosure Test Set-po in t RCIC Relay -Energize Core on Turbine Control Cont r ol Qualification Diaphragm Exhaust Agastat EGPB003 20-C621 Cooling Cab. Enclosure 289 Test Cap> Dem Pressure Above Set-Point RCIC Relay -Energize Core on Turbine Control Control Qualification Diaphragm Exhaust Agas t at EGPB003 20-C640 289 Cap> Dem Cooling Pressure Above Set-Cab. Enclosure Test Point Page 47of110 I -No. I Unit ID Type -Control 43 2 E51A-K12A Relay 44 2 E51A-K12C Control Relay E51A-K13 Control 45 2 Relay 46 E51A-K14 Control 2 Relay E51A-K16A Control 47 2 Relay Control 48 2 E51A-K16C Relay 2 E51A-K17A Control 49 Relay 50 2 E51A-K17C Control Relay 51 2 E51A-K28 Control Relay Table B-1: Components Identified for High Frequency Confirmation  
-Enclosure
-Component I Building System Function Manufacturer Model No. ID Type RCIC Relay -Energize Core on turbine Control C on t rol Diaphragm Exhaust Agastat EGPB003 20-C621 Cooling Cab. Enclosure Pressure Above Set-Point RCIC Relay -Energize Core on Turbine Control Control Cooling Diaphragm Exhaust Agastat EGPB003 20-C640 Cab. Enclosure Pressure Above Set-Point RCIC Relay-Core Energizes on Turbine Agastat EGPB003 20-C621 Control Control Cooling Exhaust Pressure Cab. Enclosure Above Set-Point RCIC Relay-Core Energizes on Turbine Agastat EGPB003 20-C621 Control Control Cooling Exhaust Pressure Cab. Enclosure Above Set-Point RCIC RELAY-Core Energizes On Steam Agastat EGPB003 20-C621 Control Control Cooling Line Pressure Below Cab. Enclosure Set-Point RCIC Relay-Core Energizes on Steam EGPB003 20-C640 Control Control Cooling Line Pressure Below Agastat Cab. Enclosure Set-Point RCIC RELAY-Core Energizes On Steam Agastat EGPB003 20-C621 Control Control Cooling Line Pressure Below Cab. Enclosure Set-Point RCIC Relay-Core Energizes on Steam Agastat EGPB002 20-C640 Control Control Cooling Line Pressure Below Cab. Enclosure Set-Point Core RCIC Turbine Tri p Agastat EGPD003 20-C621 Control Control Cooling Auxiliary Relay Cab. Enclosure 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Component Evaluation
' I Floor *1 Elev. (ft) Basis for Evaluation ca p acl tv Result Qualification 289 Cap> Dem Test Qualification 289 Test Cap> Dem 289 Qualification Cap> Dem Test 289 Qualification Cap >Dem Test 289 Qualification Cap> Dem Test 289 Qualification Cap> Dem Test 289 Qualification Cap> Dem Test 289 Qualification Cap> Dem Test 289 Qualification Cap> Dem Test Page 48 of 11 O 1 No. Unit ID f,ype ' S2 2 ES1A-K30A Control Relay ES1A-K30C Control S3 2 Relay ES1A-K31A Control S4 2 Relay SS 2 ES1A-K31C Control Relay S6 ES1A-K67C Control 2 Relay S7 1 ESlA-KlSA Control Relay Control SS 1 ESlA-KlSC Relay S9 2 ESlA-KlSA Control Relay Control 60 2 ESlA-KlSC Relay lSO/lSl-Protective 61 1 11508A Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure
--Bullc!lng System 1 Function Manufacturer Model No. ID Type I Steam Leak Detection Relay Core {RCIC Isolation Signal EGPD003 20-C621 Control Control Cooling Manual Isolation Agastat Cab. Enclosure Relay-Valve ESl-FOOS) RCIC DIV 3 Isolation Core Signal and Steam Agastat EGPD003 20-C640 Control Control Cooling Line Detection Relay Cab.
* Enclosure (ES1-F007)
RCIC Isolation Signal Core Manual Isolation Agastat EGPD003 20-C621 Control Control Cooling Relay -Valve ESl-Cab. Enclosure FOOS RCIC Isolation Signal Core Manual Isolation EGPD003 20-C640 Control Control Cooling Relay-Valve ESl-Agastat Cab. Enclosure FOOS Core RCIC DIV 3 Isolation Agastat EGPD003 20-C640 Control Control Cooling Signal Relay Cab. Enclosure Core RCIC System Steam ETR14B3B Control Control Cooling Flow Above Set-point Agastat C2004002 10-C621 Cab. Enclosure Time Delay Relay Core RCIC System Steam ETR14B3B Control Control Cooling Flow Above Set-Point Agastat C2004002 10-C640 Cab. Enclosure Time Delay Relay Core RCIC System Steam ETR14B3C Control Control Cooling Flow Above Set-point Agastat 003 20-C621 Cab. Enclosure Time Delay Relay Core RCIC System Steam ETR14B3C Control Control Cooling Flow Above Set-Point Agastat 003 20-C640 Cab. Enclosure Time Delay Relay AC/DC Power ESW Pump OAPS48 GE 121AC66KS Dll-Bus-OS Switch Control Support Overcurrent Phase A A-S gear Enclosure Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177
;1 Floor Component Evaluation Basis for !;valuation Elev. (ft) I Ca pacity Result 2S9 Qualification Cap> Dem Test 2S9 Qualification Cap> Dem Test 2S9 Qualification Cap> Dem Test 2S9 Qualification Cap> Dem Test 2S9 Qualification Cap> Dem Test Qualification 2S9 Test Cap> Dem Qualification 289 Test Cap> Dem Qua lificat1on 289 Test Cap> Dem Qualification 289 Test Cap> Dem 239 Qualification Cap> Dem Test Page 49 of 110 
-No. Unit ID f Type 62 lS0/151-Protective 1 115088 Relay lS0/151-Protective 63 1 11508C Relay 64 150/151-Protective 1 11608A Relay 65 1 150/151-Protective 116088 Relay 66 1 150/151-Protective 11608C Relay 67 2 lS0/151-Protective 11605A Relay 68 2 150/151-Protective 116058 Relay 69 2 150/151-Protective 11605C Relay 70 2 150/151-Protective 11708A Relay 71 2 150/151-Protective 117088 Relay Table B-1: Components Identified for High Frequency Confirmation C::omponent Enclosure System 1 Function Manufacturer M oile lNo. ID Type Bulldlng AC/DC Power ESW Pump OAP548 GE 121AC66K8 D11-8us-08 Switch Control Support Overcurrent Phase 8 A-S gear Enclosure Systems AC/DC Power ESW Pump OAP548 GE 121AC66K8 D11-8us-08 Switch Control Support Overcurrent Phase C A-S gear Enclosure Systems AC/DC Power ESW Pump 08PS48 GE 121AC66K8 D12-8us-08 Switch Control Support Overcurrent Phase A A-S gear Enclosure Systems AC/DC Power ESW Pump 08P548 GE 121AC66K8 D12-8us-08 Switch Control Support Overcurrent Phase 8 A-S gear Enclosure Systems AC/DC Power ESW Pump 08P548 GE 121AC66K8 D12-8us-08 Switch Control Support Overcurrent Phase C A-S gear Enclosure Systems AC/DC Power D224 Load Center GE 121AC778 D22-8us-05 Switch Control Support Overcurrent Phase A 812A-S gear Enclosure Systems AC/DC Power D224 Load Center GE 121AC778 D22-8us-05 Switch Control Support Overcurrent Phase 8 812A-S gear Enclosure Systems AC/DC Power D224 Load Center GE 121AC778 D22-8us-05 Switch Control Support Overcurrent Phase C 812A-S gear Enclosure Systems AC/DC Power ESW Pump OCP548 GE 121AC66K8 D23-8us-08 Switch Control Support Overcurrent Phase A A-S gear Enclosure Systems AC/DC Power ESW Pump OCP548 GE 121AC66K8 D23-8us-08 Switch Control Support Overcurrent Phase B A-S gear Enclosure Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Elev. (ft) Basis for Evaluation Capacity Result 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem Page 50of110 1 No. I Unit ID 150/151-Protective 72 2 11708C Relay 73 1 132-AG501 Protective Relay Protective 74 1 132-BGSOl Relay Protective 75 1 132-CGSOl Relay 132-DGSOl Protective 76 1 Relay 187G-Protective 77 1 Relay AGSOlA 187G-Protective 78 1 Relay AG501B 187G-Protective 79 1 AG501C Relay 80 187G-Protective 1 Relay BGSOlA 187G-Protective 81 1 BG501B Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure r Building System Function Manufacturer Model No. ID Type AC/DC Power ESW Pump OCP548 GE 121AC66KB D23-Bus-08 Switch Control Support Overcurrent Phase C A-S gear Enclosure Systems AC/DC Power Anti-Motoring Relay 121CW51A Dll-Bus-07 Switch Control GE 2A-S Enclosure Support gear Systems AC/DC Power Anti-Motoring Relay GE 121CW51A D12-Bus-07 Switch Control 2A-S Enclosure Support gear Systems AC/DC Power Anti-Motoring Relay GE 121CW51A Dl3-Bus-07 Switch Control 2A-S Enclosure Support gear Systems AC/DC Power Anti-Motoring Relay GE 121CW51A D14-Bus-07 Switch Control 2A-S Enclosure Support gear Systems AC/DC Power Dll A Phase GE 121JD52Al Dll-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power Dll B Phase GE 121JD52A1 Dll-Bus-07 Switch Control Support Differential Relay 1A-S Enclosure gear Systems AC/DC Power Dll C Phase GE 121JD52A1 Dll-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D12 A Phase GE 121JD52Al D12-Bus-07 Switch Control Differential Relay lA-S Enclosure Support gear Systems AC/DC Power 012 B Phase GE 121JD52Al D12-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 I Fk>or Component Evaluation I Elev. (ft) 1 Basis for Evaluation Capacity Result 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test Page51 of110 I No. I Unit I 1 10 T , ype I I 187G-Protective 82 1 Relay BGSOlC 187G-Protective 83 1 Relay CGSOlA 187G-Protective 84 1 Relay CGSOlB 187G-Protective 85 1 Relay CGSOlC 86 187G-Protective 1 Relay DGSOlA 187G-Protective 87 1 DGSOlB Relay 88 187G-Protective 1 DGSOlC Relay 132-AGSOl Protective 89 2 Relay 90 2 132-BGSOl Protective Relay 91 2 132-CGSOl Protective Relay Table B-1: Components Identified for High Frequency Confirmation
-Component Enclosure System I I Function Man uf acturer Model No. ID Type Building AC/DC Power D12 C Phase GE 121JD52Al D12-Bus-07 Switch Control Differential Relay lA-S Enclosure Support gear Systems AC/DC Power D13 A Phase 121JD52A1 D13-Bus-07 Switch Control Differential Relay GE lA-S Enclosure Support gear Systems AC/DC Power D13 B Phase GE 121JD52A1 D13-Bus-07 Switch Control Differential Relay Enclosure Support lA-S gear Systems AC/DC Power D13 C Phase GE 121JD52Al D13-Bus-07 Switch Control Differential Relay lA-S Enclosure Support gear Systems AC/DC Power D14 A Phase GE 121JD52Al D14-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D14 B Phase GE 121JD52Al D14-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D14 C Phase GE 121JD52Al D14-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power Anti-Motoring Relay GE 121CWS1A D21-Bus-07 Switch Control Support 2A-S Enclosure gear Systems AC/DC Power Anti-Motoring Relay GE 121CWS1A D22-Bus-07 Switch Control Support 2A-S gear Enclosure Systems AC/DC Power Anti-Motoring Relay GE 121CW51A D23-Bus-07 Switch Control Support 2A-S gear Enclosure Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Elev. (ft) Basis for Evaluation Capacltv Result 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test Page 52 of 110 
-No. Unit ID Type 92 2 132-DGSOl Protective Relay 187G-Protective 93 2 AGSOlA Relay 187G-Protective 94 2 AGSOlB Relay 95 2 187G-Protective AGSOlC Relay 96 187G-Protective 2 BGSOlA Relay 97 187G-Protective 2 BGSOlB Relay 98 2 187G-Protective BGSOlC Relay 187G-Protective 99 2 CGSOlA Relay 100 2 187G-Protective CGSOlB Relay 101 2 187G-Protective CGSOlC Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System Function ' Manufacturer Model No. ID Type Building AC/DC Power Anti-Motor i ng Relay GE 121CWS1A D24-Bus-07 Switch Control Support 2A-S gear Enclosure Systems AC/DC Power D21 A Phase GE 121JD52Al D21-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power 021 B Phase GE 121JD52Al D21-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D21 C Phase GE 121JD52Al D21-Bus-07 Switch Control Support Differential Relay lA-S gear Enclosure Systems AC/DC Power D22 A Phase GE 121JD52Al D22-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D22 B Phase GE 121JD52Al D22-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D22 C Phase GE 121JD52Al D22-Bus-07 Switch Control Support Differential Relay lA-S gear Enclosure Systems AC/DC Power D23 A Phase GE 121JD52Al D23-Bus-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D23 B Phase GE 121JD52Al D23-Bus-07 Switch Control Support Differential Relay lA-S gear Enclosure Systems AC/DC Power D23 C Phase GE 121JDS2Al 023-Bus-07 Switch Control Support Differential Relay lA-S gear Enclosure Systems 15C4345-RPT-002, Rev.O Correspondence No.: RS-16-177 1 Floor Component Evaluation Elev. (ft) Basis for-Evaluation Capacity Result 239 Qualification Cap> Dem Test 239 Qualification Test Cap>Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test Page 53 of 110 No. Unit ' ID Type 2 187G-Protective 102 DG501A Relay 187G-Protective 103 2 Relay DG501B 187G-Protective 104 2 DG501C Relay 150/151-Protective 105 1 11505A Relay 150/151-Protective 106 1 115058 Relay 107 1 150/151-Protective 11505C Relay 108 1 150/151-Protective 11605A Relay 109 1 150/151-Protective 116058 Relay 110 1 150/151-Protective 11605C Relay 1 150/151-Protective 111 11705A Relay Table B-1: Components Identified for High Frequency Confirmation Compon_ent Enclosure System Function Manufacturer Model No. ID I Type Bulldlng AC/DC Power D24 A Phase GE 121JD52Al D24-8us-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D24 8 Phase 121JD52Al D24-8us-07 Switch Control Support Differential Relay GE lA-S Enclosure gear Systems AC/DC Power D24 C Phase GE 121JD52Al D24-8us-07 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power D114 Load Center GE 121AC778 Dll-8us-05 Switch Control Support Overcurrent Phase A 812A-S Enclosure gear Systems AC/DC Power D114 Load Center GE 121AC77B Dll-8us-05 Switch Control Support Overcurrent Phase 8 812A-S Enclosure gear Systems AC/DC Power D114 Load Center GE 121AC778 Dll-8us-05 Switch Control Support Overcurrent Phase C 812A-S gear Enclosure Systems AC/DC Power D124 Load Center GE 121AC778 D12-8us-05 Switch Control Support Overcurrent Phase A 812A-S gear Enclosure Systems AC/DC Power D124 Load Center GE 121AC778 D12-8us-05 Switch Control Support Overcurrent Phase 8 812A-S gear Enclosure Systems AC/DC Power D124 Load Center GE 121AC778 D12-8us-05 Switch Control Support Overcurrent Phase C 812A-S gear Enclosure Systems AC/DC Power Dl34 Load Center GE 121AC778 D13-8us-05 Switch Control Support Overcurrent Phase A 812A-S Enclosure gear Systems 15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Floor Component Evaluatlon Basis for Evaluatlon Elev. (ft) canadtv Result 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap>Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem Page 54of110 No. I ID Type -112 150/151-Protective 1 117058 Relay 150/151-Protective 113 1 11705C Relay 114 1 150/151-Protective 11805A Relay 115 150/151-Protective 1 118050 Relay 116 1 150/151-Protective 11805C Relay 117 2 150/151-Protective 11505A Relay 118 2 150/151-Protective 115050 Relay 119 150/151-Protective 2 11505C Relay 120 2 150/151-Protective 11705A Relay 121 2 150/151-Protective 117058 Relay Table B-1: Components Identified for High Frequency Confirmation Component
-Enclosure System I Function Manufacturer Model No. ID Type Building -AC/DC Power D134 Load Center GE 121AC77B D13-Bus-05 Switch Control Support Overcurrent Phase B 812A-S Enclosure gear Systems AC/DC Power D134 Load Center GE 121AC77B D13-Bus-05 Switch Control Support Overcurrent Phase C 812A-S Enclosure gear Systems AC/DC Power D144 Load Center GE 121AC77B D14-Bus-05 Switch Control Support Overcurrent Phase A 812A-S gear Enclosure Systems AC/DC Power D144 Load Center GE 121AC77B D14-0us-05 Switch Control Support Overcurrent Phase 0 812A-S Enclosure gear Systems AC/DC Power D144 Load Center GE 121AC770 D14-0us-05 Switch Control Support Overcurrent Phase C 812A-S gear Enclosure Systems AC/DC Power D214 Load Center GE 121AC770 D21-0us-05 Switch Control Support Overcurrent Phase A 812A-S gear Enclosure Systems AC/DC Power D214 Load Center GE 121AC77B D21-Bus-05 Switch Control Support Overcurrent Phase 0 812A-S gear Enclosure Systems AC/DC Power D214 Load Center GE 121AC77B D21-Bus-05 Switch Control Support Overcurrent Phase C 812A-S Enclosure gear Systems AC/DC Power D234 Load Center GE 121AC77B D23-Bus-05 Switch Control Support Overcurrent Phase A 812A-S gear Enclosure Systems AC/DC Power D234 Load Center GE 121AC770 D23-0us-05 Switch Control Support Overcurrent Phase B 812A-S gear Enclosure Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 11 Floor i Co!!Jponent Evaluation J;lev. (ft) Basis for Evaluation Capacity Result 239 Qualification Cap> Dem Test 239 Qualification Cap>Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem Page 55 of 110 No.! r: n-lt l H T, ype' J 150/151-Protective 122 2 11705C Relay 150/151-Protective 123 2 Relay 11805A 150/151-Pro t ective 124 2 118058 Rela y 150/151-Protective 125 2 11805C Relay 150/151-Protecti v e 126 2 Relay 11808A 150/151-Protective 127 2 118088 Relay 150/151-Protective 128 2 11808C Relay 129 151-11 7 02 A P r otective 1 Relay 130 1 151-11702B Protec t i v e Relay 151-11 7 02C Protective 131 1 Relay 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure l
I Floor Component Evaluation I
! I : Model No. I? Elev. (ft) Basis for Evaluation capacity Result AC/DC Power D234 Load Center GE 121AC77B D23-Bus-05 Switch Control 239 Qualification Cap> Dem Support Overcurrent Phase C 812A-S Enclosure Test gear Systems AC/DC Power 0244 Load Center G E 121AC77B D24-Bus-05 Switch Control 239 Qualification Cap>Dem Support Overcurrent Phase A 812A-S Enclosure Test gear S y stems AC/DC Power D244 Load Center GE 121AC77B D24-Bus-05 Switch Control 239 Qualification Cap> Dem Support Overcurrent Phase B 8 1 2A-S Enclosure Test gear Systems AC/DC Power D244 Load Center G E 121 A C77B D24-Bus-05 Switch Control 239 Qualification Cap> Dem Support Overcurrent Phase C 812A-5 Enclosure Test gear Systems A C/DC Power ESW Pump ODP548 GE 12JAC66K8 D24-Bus-08 Switch Control 239 Qualification Cap> Dem Overcurrent Phase A A-S Enclosure Test Support gear Systems AC/DC Power ESW Pump ODP548 GE 121AC66K8 024-Bus-08 Switch Control 239 Qualification Cap> Dem Support Overcurrent Phase 8 A-S Enclosure Test gear Systems A C/DC Po w er ESW Pump ODP548 GE 121AC66K8 D24-8us-08 Switch Control 239 Qualification Cap> Dem Support Overcurrent Phase C A-S Enclosu r e Test gear Systems AC/DC A117 Breaker 702 Power Bus A Phase GE 121 A C53A D13-Bus-02 Switch Control 239 Qualification Cap> Dem Support 802A-S Enclosure Test Overcurrent Relay gear S y stems AC/DC All 7 Breaker 702 Power Bus B Phase GE 121 A C53A 013-Bus-02 Switch Control 239 Qualification Cap> Dem Support Overcurrent Relay 802A-S gear Enclosu r e Test S y stems A C/DC All 7 Breaker 702 Power Bus C Phase GE 121 A C53A D13-Bus-02 Switch Control 239 Qualification Support 802 A-S Enclosure Test Cap> Dem Overcurrent Relay gear S y stems Page 56of110 
--No. Unit ID Type .J Protectrve 132 1 151-11709A Relay 133 1 151-11709B Protective Relay 134 1 151-11709C Protective Relay 151-Protective 135 1 AG501A Relay 136 151-Protective 1 AG501B Relay 151-Protective 137 1 AG501C Relay 138 151-Protective 1 Relay BG501A 139 151-Protective 1 BG501B Relay 140 151-Protective 1 BG501C Relay 151-Protective 141 1 CG501A Relay Table B-1: Components Identified for High Frequency Confirmation
-Enclosure , Component f System Function Manufacturer Model l No. ID Type BuUdlng AC/DC A117 Breaker 709 Power 12JAC53A Switch Control Bus A Phase GE 802A-S D13-Bus-09 Enclosure Support Overcurrent Relay gear Systems AC/DC A117 Breaker 709 Power 121AC53A Switch Control Bus B Phase GE 802A-S D13-Bus-09 Enclosure Support Overcurrent Relay gear Systems AC/DC All 7 Breaker 709 Power 121AC53A Switch Control Bus C Phase GE 802A-S D13-Bus-09 Enclosure Support Overcurrent Relay gear Systems AC/DC Power Phase Overcurrent GE 121AC53A Dll-Bus-07 Switch Control Support Relay Phase A 802A-5 Enclosure gear Systems AC/DC Power Phase Overcurrent GE 12JAC53A Dll-Bus-07 Switch Control Support Relay Phase B 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 121AC53A Dll-Bus-07 Swrtch Control Support Relay Phase C 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 12JAC53A D12-Bus-07 Switch Control Support Relay Phase A 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 121AC53A D12-Bus-07 Switch Control Support Relay Phase B 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 121AC53A D12-Bus-07 Switch Control Support Relay Phase C 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 121AC53A D13-Bus-07 Switch Control Support Relay Phase A 802A-S Enclosure gear Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Elev. (ft) Basis for Evaluation Caoadtv Result Qualrfication 239 Test Cap> Dem Qualification 239 Test Cap>Dem Qualification 239 Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test Page 57 of 110 No. -Type ' ID 142 1 151-Protective CG501B Relay 151-Protective 143 1 CG501C Relay 144 1 151-P r otective DG501 A Relay 145 1 151-Protective DG501B Relay 146 1 lSl-Protective DG501C Relay Protective 147 1 151-11502A Relay 148 1 151-11502B Protective Relay Protective 149 1 151-11502C Relay 150 1 151-11509 A Protective Relay 151 1 151-1 1509B Pro t ective Relay 15C4345-RPT-002, Rev. 0 C o rrespondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component
-r Encl o sure : . ' I [ Building I Floor Component Evaluation
* l I [ , r-[Type_ I Bas i s for Evaluation E l ev. (ft} Ca pacify Result AC/DC Power Phase Overcurrent GE 121AC53A D13-Bus-07 Switch Control 239 Qualification Cap> Dem Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC Power Phase Overcurrent GE 121AC53A D13-Bus-07 Switch Control 239 Qualification Support Relay Phase C 802A-S Enclosure Cap> Dem gear Test Systems AC/DC Power Phase Overcurrent GE 121 A C53A D14-Bus-07 Switch Control 239 Qualification Cap> Dem Support Relay Phase A 802A-S gear Enclosu r e Test Systems AC/DC Power Phase Overcurrent GE 121AC53A D14-Bus-07 Switch Control 239 Qualification Cap> Dem Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC Po w er Phase Overcurrent GE 121AC53A D14-Bus-07 Switch Control 239 Qualification Cap> Dem Support Relay Phase C 802A-S gear Enclosu r e Test S y stems AC/DC A115 Breaker 502 Power 121ACS3A Switch Control Qualification Bus A Phase GE Dll-Bus-02 239 Cap> Dem Support Overcur r ent Relay 802A-S gear Enclosure Test S y stems AC/DC A115 Breake r 502 Po w er Bus B Phase GE 121AC53A Dll-Bus-02 Switch Control 239 Qualification Support 802A-S gear Enclosu r e Test Cap> Dem S y stems Overcurrent Relay A C/DC A115 Breaker 502 Po w er 121AC53A Switch Control Qualification Support Bus C Phase GE 802 A-S Dll-Bus-02 Enclosure 239 Cap> Dem Overcurrent Relay gear Test S y stems A C/DC A115 Breaker 509 Power Bus A Phase GE 121AC53A Dll-Bus-09 Switch Control 239 Qualification Support 802A-S gear Enclosure Test Cap> Dem S y stems Over c urrent Relay A C/DC A115 Breaker 509 Po w er Bus B Phase GE 121AC53A Dll-Bus-09 Switch Co n t r ol 239 Qualification Support 802A-S gear Enclosu r e Test Cap> Dem Systems Overcur r ent Relay Page 58of110 a , No. ![ ID T , ype 152 1 151-11509C Protective Relay 153 1 151-11602A Protective Relay 1 151-11602B Protective 154 Relay 155 1 151-11602C Protective Relay 156 1 151-11609A Protective Relay 157 1 151-11609B Protective Relay Protective 158 1 151-11609C Relay Protective 159 1 151-11802A Relay 160 1 151-11802B Protective Relay Protective 161 1 151-11802C Relay 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure
: i Floor Comp()nent Evaluation
--[
I ID I Basis for Evaluation Function l;lev. (ft) Capacity Result AC/DC A115 Breaker 509 Power Bus C Phase GE 121AC53A Dll-Bus-09 Switch Control . 239 Qualification Cap> Dem Support Overcurrent Relay 802A-S gear Enclosure Test Systems AC/DC A116 Breaker 602 Power 121AC53A Switch Control Qualification Support Bus A Phase GE 802A-S D12-Bus-02 Enclosure 239 Test Cap> Dem Overcurrent Relay gear Systems AC/DC A116 Breaker 602 Power Bus B Phase GE 121AC53A D12-Bus-02 Switch Control 239 Qualification Cap> Dem Support 802A-S Enclosu re Test Overcurrent Relay gear Systems AC/DC A116 Breaker 602 Power Bus C Phase GE 121AC53A D12-Bus-D2 Switch Control 239 Qualification Cap> Dem Support Overcurrent Relay 802A-S gear Enclosure Test Systems AC/DC A116 Breaker 609 Power Bus A Phase GE 121AC53A D12-Bus-09 Switch Control 239 Qualification Cap> Dem Support Overcurrent Relay 802A-S gear Enclosure Test Systems AC/DC A116 Breaker 609 Power Bus B Phase GE UIAC53A D12-Bus-09 Switch Control 239 Qualification Support B02A-S Enclosu re Test Cap> Dem Overcurrent Relay gear Systems AC/DC A116 Breaker 609 Power 121AC53A Switch Control Qualification Bus c Phase GE D12-Bus-09 239 Cap> Dem Support Overcurrent Relay 802A-S gear Enclosure Test Systems AC/DC A118 Breaker 802 Power 121AC53A Switch Control Qualification Support Bus A Phase GE 802A-S D14-Bus-02 Enclosure 239 Test Cap> Dem Overcurrent Relay gear Systems AC/DC AllB Breaker 802 Power Bus B Phase GE 121AC53A D14-Bus-02 Switch Control 239 Qualification Cap> Dem Support 802A-S gear Enclosu r e Test Systems Overcurrent Relay AC/DC All8 Breaker 802 Power 121 AC5 3A Switch Control Qualification Support Bus C Phase GE 802A-S D14-Bus-02 Enclosure 239 Test Cap> Dem Overcurrent Relay gear Systems Page 59 of 110 I Unit No. I ID T,ype l 162 151-11809A Protective 1 Relay 163 1 151-11809B Protective Relay 164 1 151-11809C Protective Relay 16S 2 151-11702A Protective Relay 166 2 1Sl-11702B Protective Relay 167 2 151-11702C Protective Relay 168 2 151-11709A Protective Relay 169 2 151-11709B Protective Relay 170 2 151-11709C Protective Relay 171 2 151-Protective AG501A Relay Table B-1: Components Identified for High Frequency Confirmation
--Component Enclosure
' Building System ' Function Man ufa cturer Model No. ID Type -AC/DC A118 Breaker 809 Power Bus A Phase GE 121AC53A D14-Bus-09 Switch Control Support 802A-S Enclosure Overcurrent Relay gear Systems AC/DC A118 Breaker 809 Power 121AC53A Switch Control Support Bus B Phase GE 802A-S D14-Bus-09 Enclosure Overcurrent Relay gear Systems AC/DC A118 Breaker 809 Power Bus C Phase GE 121AC53A D14-Bus-09 Switch Control Support 802A-S Enclosure Overcurrent Relay gear Systems AC/DC A117 Breaker 702 Power Bus A Phase GE 121AC53A D23-Bus-02 Switch Control Support Overcurrent Relay 802A gear Enclosure Systems AC/DC A117 Breaker 702 Power Bus B Phase GE 121AC53A D23-Bus-02 Switch Control Support Overcurrent Relay 802A gear Enclosure Systems AC/DC A117 Breaker 702 Power Bus C Phase GE 121AC53A D23-Bus-02 Switch Control Support Overcurrent Relay 802A gear Enclosure Systems AC/DC All 7 Breaker 709 Power Bus A Phase GE 121AC53A D23-Bus-09 Switch Control Support 802A-S Enclosure Overcu rrent Relay gear Systems AC/DC A117 Breaker 709 Power Bus B Phase GE 121AC53A D23-Bus-09 Switch Control Support 802A-S Enclosure Overcurrent Relay gear Systems AC/DC A117 Breaker 709 Power Bus C Phase GE 121AC53A D23-Bus-09 Switch Control Support Overcurrent Relay 802A-S gear Enclosure Systems AC/DC Power Phase Overcurrent GE 121AC53A D21-Bus-07 Switch Control Support Relay Phase A 802A-S gear Enclosure Systems 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Floor Component Evaluatio_11 I Basis for Evaluation Elev. (ft) Capacity Result 239 Qualification Cap> Dem Test Qualification 239 Test Cap >Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem Page 60of110 No. Unit I ID Type -172 151-Protective 2 AG501B Relay 151-Protective 173 2 AG501C Relay 174 2 151-Protective BG501A Relay 175 151-Protective 2 BG501B Relay 176 2 151-Protective BG501C Relay 177 2 151-Protective CG501A Relay 178 2 151-Protective CG501B Relay 179 2 151-Protective CG501C Relay 180 2 151-Protective DG501A Relay 181 2 151-Protective DGS01B Relay Table B-1: Components Identified for High Frequency Confirmation Component I Enclosure System Function Manufacturer Model No. ID Type Building AC/DC Power Phase Overcurrent GE 121ACS3A D21-Bus-07 Switch Control Support Relay Phase B 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 121ACS3A D21-Bus-07 Switch Control Support Relay Phase C 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 121ACS3A D22-Bus-07 Switch Control Support Relay Phase A 802A-S gear Enclosure Systems AC/DC Power Phase Overcurrent GE 12JACS3A D22-Bus-07 Switch Control Support Relay Phase B 802A-S Enclosure gear Systems AC/DC Power Phase Overcurrent GE 12JACS3A D22-Bus-07 Switch Control Support Relay Phase C 802A-S gear Enclosure Systems AC/DC Power Phase Overcurrent GE 12JACS3A D23-Bus-07 Switch Control Support Relay Phase A 802A-S gear Enclosure Systems AC/DC Power Phase Overcurrent GE 121ACS3A D23-Bus-07 Switch Control Support Relay Phase B 802A-S gear Enclosure Systems AC/DC Power Phase Overcurrent GE 121ACS3A D23-Bus-07 Switch Control Support Relay Phase C 802A-S gear Enclosure Systems AC/DC Power Phase Overcurrent GE 121ACS3A D24-Bus-07 Switch Control Support Relay Phase A 802A-S gear Enclosure Systems AC/DC Power Phase Overcurrent GE 121AC53A D24-Bus-07 Switch Control Support Relay Phase B 802A-S gear Enclosure Systems 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Compo!ll!nt Evaluation I Elev. (ft) j Basis for Evaluation Capacity Result 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap>Dem Test 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test Page 61 of 110 1 --No. Unit ID Type 182 2 151-Protective DG501C Relay Protective 183 2 151-11502A Relay 184 2 151-11502B Protective Relay 185 2 151-11502C Protective Relay 186 2 151-11509A Protective Relay Protective 187 2 1Sl-11509B Relay Protective 188 2 151-11509C Relay Protective 189 2 151-11602A Relay Protective 190 2 151-11602B Relay Protective 191 2 151-11602C Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System Function Manufacturer Model No. ID Type Building AC/DC Power Phase Overcurrent GE 121AC53A D24-Bus-07 Switch Control Support Relay Phase C 802A-S gear Enclosure Systems AC/DC A115 Breaker 502 Power 121AC53A Switch Control Support Bus A Phase GE 802A-S D21-Bus-02 Enclosure Overcurrent Relay gear Systems AC/DC A115 Breaker 502 Power Bus B Phase GE 121AC53A D21-Bus-02 Switch Control Support 802A-S Enclosure Overcurrent Relay gear Systems AC/DC A115 Breaker 502 Power Bus C Phase GE 121AC53A D21-Bus-02 Switch Control Support 802A-S Enclosure Overcurrent Relay gear Systems AC/DC A115 Breaker 509 Power Bus A Phase GE 121AC53A D21-Bus-09 Switch Control Support 802A-S gear Enclosure Systems Overcurrent Relay AC/DC A115 Breaker 509 Power 121AC53A Switch Control Bus B Phase GE D21-Bus-09 Support Overcurrent Relay 802A-S gear Enclosure Systems AC/DC A115 Breaker 509 Power 121AC53A Switch Control Support Bus C Phase GE 802A-S D21-Bus-09 Enclosure Overcurrent Relay gear Systems AC/DC A116 Breaker 602 Power 121AC53A Switch Control Support Bus A Phase GE 803A D22-Bus-02 Enclosure Overcurrent Relay gear Systems AC/DC A116 Breaker 602 Power 121AC53A Switch Control Support Bus B Phase GE 802A-S D22-Bus-02 Enclosure Overcurrent Relay gear Systems AC/DC A116 Breaker 602 Power 121AC53A Switch Control Support Bus C Phase GE 802A-S D22-Bus-02 Enclosure Overcurrent Relay gear Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Component Evaluation Floor I Basis for I Evaluation Elev. (ft) Capacltv Result 239 Qualification Test Cap> Dem Qualification 239 Test Cap>Dem 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem Qualification 239 Cap>Dem Test Qualification 239 Cap> Dem Test Qualification 239 Cap >Dem Test Qualification 239 Cap> Dem Test Qualification 239 Cap> Dem Test Page 62 of 110 I -No. Unit I ID Type _j Protective 192 2 151-11609A Relay Protective 193 2 151-11609B Relay Protective 194 2 151-11609C Relay Protective 195 2 151-11802A Relay Protective 196 2 151-11802B Relay Protective 197 2 151-11802C Relay Protective 198 2 151-11809A Relay Protective 199 2 1Sl-11809B Relay 151-11809C Protective 200 2 Relay 151N-Protective 201 1 11502 Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure
' ' Building System Function Manufacturer Model No. ID Type AC/DC A116 Breaker 609 Power 121AC53A Switch Control Support Bus A Phase GE 802A-S D22-Bus-09 Enclosure Overcurrent Relay gear Systems AC/DC A116 Breaker 609 Power 121AC53A Switch Control Bus B Phase GE 802A-S D22-Bus-09 Enclosure Support Overcurrent Relay gear Systems AC/DC A116 Breaker 609 Power 121AC53A Switch Control Bus C Phase GE 802A-S D22-Bus-09 Enclosure Support Overcurrent Relay gear Systems AC/DC A118 Breaker 802 Power 121AC53A Switch Control Bus A Phase GE 802A-S D24-Bus-02 Enclosure Support Overcurrent Relay gear Systems AC/DC A118 Breaker 802 Power 121AC53A Switch Control Bus B Phase GE 802A-S D24-Bus-02 Enclosure Support Overcurrent Relay gear Systems AC/DC A118 Breaker 802 Power Bus C Phase GE 121AC53A D24-Bus-02 Switch Control Support 802A-S Enclosure Overcurrent Relay gear Systems AC/DC All8 Breaker 809 Power 121AC53A Switch Control Bus A Phase GE 802A-S D24-Bus-09 Enclosure Support Overcurrent Relay gear Systems AC/DC A118 Breaker 809 Power 121AC53A Switch Control Bus B Phase GE 802A-S D24-Bus-09 Enclosure Support Overcurrent Relay gear Systems AC/DC All8 Breaker 809 Power Bus C Phase GE 121AC53A D24-Bus-09 Switch Control 802A-S Enclosure Support Overcurrent Relay gear Systems AC/DC All5 Breaker 502 Power Neutral Overcurrent GE 121AC51A Dll-Bus-02 Switch Control 801A-S Enclosure Support Relay gear Systems 15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 11 Floor Component Evaluation Elev. (ft) Basis for Evaluation
(;apacltv Result Qualification 239 Test Cap> Dem Qualification 239 Test Cap> Dem Qualification 239 Test Cap> Dem Qualification 239 Test Cap> Dem Qualification 239 Test Cap> Dem 239 Qualification Cap> Dem Test Qualification 239 Test Cap>Dem Qualification 239 Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test Page 63 of 110 
--** No. [ Unit :Type 11 ID I lSlN-Protective 202 1 11S09 Relay 203 1 lSlN-11602 Protective Relay 1S1N-Protective 204 1 Relay 11609 1S1N-Protective 20S 1 11702 Relay 1S1N-Protective 206 1 11709 Relay 1S1N-Protective 207 1 11802 Relay 1S1N-Protective 208 1 11809 Relay lSlN-Protective 209 2 11S02 Relay 2 lSlN-Protective 210 11S09 Relay 1S1N-Protective 211 2 11602 Relay 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
*-Component Enclosure Component Evaluation
-Floor j Building Elev. {ft) , Basis 1 for Evaluation System I Function Manufacturer Model No. ID Type ___j Capacity Result AC/DC AllS Breaker S09 Power Neutral Overcurrent GE 121ACS1A Dll-Bus-09 Switch Control 239 Qualification Cap> Dem Support 801A-S Enclosure Test Relay gear Systems AC/DC A116 Breaker 602 Power 121AC51A Switch Control Qualification Neutral Overcurrent GE 801A-S D12-Bus-02 Enclosure 239 Test Cap>Dem Support gear Systems Relay AC/DC A116 Breaker 609 Power Neutral Overcurrent GE 121ACS1A D12-Bus-09 Switch Control 239 Qualification Cap> Dem 801A-S Enclosure Test Support gear Systems Relay AC/DC All 7 Breaker 702 Power Neutral Overcurrent GE 121AC51A D13-Bus-02 Switch Control 239 Qualification Cap> Dem Support 801A-S Enclosure Test Relay gear Systems AC/DC All 7 Breaker 709 Power 121AC51A Switch Control Qualification Support Neutral Overcurrent GE 801A-S D13-Bus-09 Enclosure 239 Test Cap >Dem Relay gear Systems AC/DC A118 Breaker 802 Power Neutral Overcurrent GE 121AC51A D14-Bus-02 Switch Control 239 Qualification Cap> Dem Support 801A-S Enclosure Test Relay gear Systems AC/DC A118 Breaker 809 Power Neutral Overcurrent GE 121AC51A D14-Bus-09 Switch Control 239 Qualification Cap> Dem Support 801A-S Enclosure Test Relay gear Systems AC/DC AllS Breaker S02 Power Neutral Overcurrent GE 121AC51A D21-Bus-02 Switch Control 239 Qualification Cap> Dem Support 801A-S Enclosure Test Relay gear Systems AC/DC AllS Breaker S09 Power Neutral Overcurrent GE 121ACS1A D21-Bus-09 Switch Control 239 Qualification Cap> Dem Support 801A-S Enclosure Test Relay gear Systems AC/DC A116 Breaker 602 Power Neutral Overcurrent 121ACS1A D22-Bus-02 Switch Control 239 Qualification Cap> Dem Support GE 801A-S Enclosure Test Relay gear Systems Page 64 of 110 No. Unit I I ID Type 212 2 151N-Protective 11609 Relay 151N-Protective 213 2 11702 Relay 214 2 151N-Protective 11709 Relay 215 2 151N-Protective 11802 Relay 216 2 151N-Protective 11809 Relay 217 186-115A Control 1 Relay 218 1 186-115B Control Relay 219 1 186-llSC Control Relay 220 1 186-116A Control Relay 221 186-116B Control 1 Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure
-Building System Function Manufacturer Model 1 No. ID Type -AC/DC A116 Breaker 609 Power Neutral Overcurrent GE 121AC51A D22-Bus-09 Switch Control Support Relay 801A-S gear Enclosure Systems AC/DC All 7 Breaker 702 Power Neutral Overcurrent GE 121AC51A D23-Bus-02 Switch Control Support 801A-S Enclosure Relay gear Systems AC/DC All 7 Breaker 709 Power Neutral Overcurrent GE 121AC51A D23-Bus-09 Switch Control Support Relay 801A-S gear Enclosure Systems AC/DC A118 Breaker 802 Power Neutral Overcurrent GE 121AC51A D24-Bus-02 Switch Control Support Relay 801A-S gear Enclosure Systems AC/DC A118 Breaker 809 Power Neutral Overcurrent GE 121AC51A D24-Bus-09 Switch Control Support Relay 801A-S gear Enclosure Systems AC/DC Power A115 Bus Lockout Electroswitch Series 24 Dll-Bus-06 Switch Control Support Relay Enclosure gear Systems AC/DC Power A115 Bus Lockout Electroswitch Series 24 Dll-Bus-09 Switch Control Support Relay gear Enclosure Systems AC/DC Power Al15 Bus Lockout Electroswitch Series 24 Dll-Bus-09 Switch Control Support Relay gear Enclosure Systems AC/DC Power Al16 Bus Lockout Electroswitch Series 24 D12-Bus-06 Switch Control Support Relay gear Enclosure Systems AC/DC Power A116 Bus Lockout Electroswitch Series 24 D12-Bus-09 Switch Control Support Relay Enclosure gear Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Basis for Evaluation Elev. (ft) capacity __ Result 239 Quahficat1on Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem Page 65 of 11 O j B No. I 222 1 186-116C Control Relay 223 1 186-117A Control Relay 224 1 186-11 7 B Control Relay 225 1 186-117C Control Relay 226 1 186-118A Con t rol Relay 227 1 186-11 8B Control Relay 228 1 186-118C Con t rol Relay 229 1 186-A GSOl Control Rela y 230 1 186-BGSOl Control Relay 231 1 186-CGSOl Con t rol Rela y 15C4345-RPT
-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
-Component
---Enclosure t uildlng] Floor Component Evaluation J
c ; 'I for Evaluation Funct i on Model No. ID Type Elev. (ft) caoacJty , R esult AC/DC Power All6 Bus Lockout Electroswitch Series 24 D12-Bus-09 Switch Control 239 Qualification Support Relay gear Enclosure Test Cap> Dem Systems AC/DC Power All 7 Bus Lockout Electroswitch Series 24 D13-Bus-06 Switch Control 239 Qualification Support Relay Enclosure Test Cap>Dem gear Systems AC/DC Power All 7 Bus Lockout Electroswitch Series 24 D13-Bus-09 Switch Control 239 Qualification Cap> Dem Support Relay gear Enclosure Test Systems AC/DC Power All 7 Bus Lockout Electroswitch Series 24 D13-Bus-09 Switch Control 239 Qualification Support Relay gear Enclosu r e Test Cap> Dem Systems AC/DC Power All 8 Bus Lockout Electroswitch Series 24 D14-Bus-06 Switch Control 239 Qualification Support Relay gear Enclosure Test Cap> Dem Systems AC/DC Power All8 Bus Lockout Electros w i tch Series 24 D14-Bus-09 Switch Control 239 Qualification Support Relay gear Enclosure Test Cap> Dem Systems AC/DC Power A118 Bus Lockout Electroswitch Series 24 D14-Bus-09 Switch Control Qualification Support Relay Enclosure 239 Cap> Dem gear Test Systems A C/DC Power Dll Lockout Relay Electroswitch Series 24 Dll-Bus-0 7 Switch Control 239 Qualificat i on Support gear Enclosure Test Cap> Dem Systems A C/DC Power D12 Lockout Relay Electroswitch Series 24 D12-Bus-0 7 Switch Control 239 Qualification Support gear Enclosu r e Test Cap> Dem Systems A C/DC Po w er D13 Lockout Relay Electroswitch Series 24 Dl3-Bus-07 Switch Control 239 Qualification Support gear Enclosure Test Cap> Dem S y stems Page 66 of 110 No. I <Unit r -ID T.'(111! 232 1 186-DGSOl Control Relay 233 2 186-llSA Control Relay 186-llSB Control 234 2 Relay 235 2 186-115C Control Relay 236 2 186-116A Control Relay 237 2 186-116B Control Relay 238 2 186-116C Control Relay 239 2 186-117A Control Relay 240 2 186-117B Control Relay 241 2 186-117C Control Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System Function I ' Manufacturer Model No. ID Type Building ' AC/DC Power D14 Lockout Relay Electroswitch Series 24 D14-Bus-07 Switch Control Support gear Enclosure Systems AC/DC Power A115 Bus Lockout Electroswitch Series 24 D21-Bus-06 Switch Control Support Relay Enclosure gear Systems AC/DC Power A115 Bus Lockout Electroswitch Series 24 D21-Bus-09 Switch Control Support Relay Enclosure gear Systems AC/DC Power A115 Bus Lockout Electroswitch Series 24 D21-Bus-09 Switch Control Support Relay gear Enclosure Systems AC/DC Power A116 Bus Lockout Electroswitch Series 24 D22-Bus-06 Switch Control Support Relay gear Enclosure Systems AC/DC Power A116 Bus Lockout Electroswitch Series 24 D22-Bus-09 Switch Control Support Relay gear Enclosure Systems AC/DC Power A116 Bus Lockout Electroswitch Series 24 D22-Bus-09 Switch Control Support Relay gear Enclosure Systems AC/DC Power All 7 Bus Lockout Electroswitch Series 24 D23-Bus-06 Switch Control Support Relay gear Enclosure Systems AC/DC Power A117 Bus Lockout Electroswitch Series 24 D23-Bus-09 Switch Control Support Relay gear Enclosure Systems AC/DC Power All 7 Bus Lockout Electroswitch Series 24 Switch Control Support Relay D23-Bus-09 Enclosure gear Systems 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Evaluation Elev. (ft) [ Basis 1 for Evaluation I Capadtv Result 239 Qualification Cap> Dem Test 239 Qualification Cap>Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem 239 Qua Jification Test Cap> Dem 239 Qualification Test Cap> Dem Qualification 239 Test Cap> Dem Page 67of110 El No. JI & ID Type 242 2 186-118A Control Relay 186-llBB Control 243 2 Relay 244 2 186-118C Control Rela y 245 2 186-AGSOl Control Relay 246 2 186-BGSOl Cont r ol Relay 247 2 186-CGSOl Control Relay 248 2 186-DGSOl Control Relay 249 150G-Protective 1 11505 Relay 250 1 150G-Protective 11508 Relay 251 1 150G-Protective 11605 Relay 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component c Enclosure
* '* J Floor Col!lponent Evaluation ff svste;J K 11 Manufacturer
! Basis for Evaluation Model 1 No. Elev. {ft) Cai>ac l tv Resu l t AC/DC Power A118 Bus Lockout Electroswitch Series 24 D24-Bus-06 Switch Control 239 Qualification Cap> Dem Support Relay gear Enclosure Test Systems AC/DC Power A118 Bus Lockout Electroswitch S eries 2 4 D24-Bus-09 Switch Control 239 Qualification Support Relay Enclosure Test Cap> Dem gear Systems AC/DC Power A118 Bus Lockout Electroswitch Series 24 D24-Bus-09 Switch Control 239 Qualification Cap> Dem Support Relay gear Enclosure Test Systems AC/DC Power D21 Lockout Relay Electroswitch Series 24 D21-Bus-0 7 Switch Control 239 Qualification Support gear Enclosure Test Cap> Dem Systems AC/DC Power D22 Lockout Relay Electroswitch Series 24 D22-Bus-0 7 Switch Control 239 Qualification Support gear Enclosu r e Test Cap> Dem Systems AC/DC Power D23 Lockout Relay Electroswitch Series 24 D23-Bus-07 Switch Control 239 Qualification Support gear Enclosure Test Cap>Dem Systems AC/DC Power D24 Lockout Relay Electroswitch Series 24 D24-Bus-07 Switch Control 239 Qualification Support gear Enclosure Test Cap> Dem Systems AC/DC Power Dl14 Load Center 12HFC11B Dll-Bus-05 Switch Control 239 Qualification Support Ground Fault GE lA-S Enclosu r e Test Cap> Dem gear S y stems AC/DC Po w er ESW Pump OAP548 GE 12HFC11B Dll-Bus-08 Switch Control 239 Qualification Support Ground Fault lA-S gear Enclosure Test Cap> Dem Systems AC/DC Power D124 Load Center 12HFC11B Switch Control Qualification Support Ground Fault GE lA-S D12-Bus-05 Enclosure 239 Cap> Dem gear Test Systems Page 68 of 110 
''EJ No. ; Unit: 150G-Protective 252 1 11608 Relay 150G-Protective 253 1 Relay 11705 150G-Protective 254 1 Relay 11805 151N-Protective 255 1 AG501 Relay 151N-Protective 256 1 Relay BGSOl lSlN-Protective 257 1 CGSOl Relay 151N-Protective 258 1 DG501 Relay Protective 259 1 187-llSA Relay 187-1158 Protective 260 1 Relay Protective 261 1 187-llSC Relay 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure r Floor Component Evaluation
-I -:J l j -Basis for , Evaluation System Model No. ID Type Elev. {ft) Capacltv Result AC/DC Power ESW Pump OBP548 GE 12HFC11B D12-Bus-08 Switch Control 239 Qualification Cap> Dem Support Ground Fault lA-S gear Enclosure Test Systems AC/DC Power Dl34 Load Center GE 12HFC11B D13-Bus-05 Switch Control 239 Qualification Cap> Dem Ground Fault lA Enclosure Test Support gear Systems AC/DC Power D144 Load Center GE 12HFC11B D14-Bus-05 Switch Control 239 Qualification Cap> Dem Ground Fault lA-S Enclosu re Test Support gear Systems AC/DC Power Dll Neutral Westinghous 264C899A Dll-Bus-07 Switch Control 239 Qualification Cap> Dem Support Overcurrent Relay 01 Enclosure Test e gear Systems AC/DC Power D12 Neutral westinghous 264C899A D12-Bus-07 Switch Control 239 Qualification Cap> Dem Overcurrent Relay 01 Enclosu re Test Support e gear Systems AC/DC Power D13 Neutral Westinghous 264C899A D13-Bus-07 Switch Control 239 Qualification Cap> Dem Support Overcurrent Relay 01 Enclosure Test e gear Systems AC/f?C Power D14 Neutral Westinghous 264C899A D14-Bus-07 Switch Control 239 Qualification Cap>Dem Support Overcurrent Relay 01 Enclosure Test e gear Systems AC/DC Power AllS Bus A Phase GE 12PVD21B Dll-Bus-06 Switch Control 239 Qualification Cap> Dem Support Differentia I Relay lA-S Enclosure Test gear Systems AC/DC Power Al15 Bus B Phase GE 12PVD21B Dll-Bus-06 Switch Control 239 Qualification Cap> Dem Differential Relay Enclosure Test Support lA-S gear Systems AC/DC Power AllS Bus C Phase GE 12PVD21B Switch Control 239 Qualification Cap> Dem Differential Relay lA-S Dll-Bus-06 Enclosure Test Support gear Systems Page 69 of 110 
, No. j t [ 1 10 _J[ Type J 262 1 187-116A Protective Relay 263 1 187-116B Protective Relay 264 1 187-116C Protective Relay 265 1 187-117A Protective Relay 266 1 187-117B Protective Relay 267 187-117C Protective 1 Relay 268 1 187-118A Protective Relay 269 187-ll SB Protective 1 Relay 270 1 187-llSC P r otective Relay 271 2 150G-Protective 11505 Relay 15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component
-I
* EnclOsure
----=i Floor f omponent Evaluation I I System] J ; Manufacturer Model No. ID Elev. (ft) 1 Basis for Evaluat i on Caoacltv Result AC/DC Power A116 Bus A Phase GE 12PVD21B D12-Bus-06 Switch Control 239 Qualification Cap> Dem Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Power A116 Bus B Phase GE 12PVD21B D12-Bus-06 Switch Control 239 Qualification Cap> Dem Support Differential Relay lA-S Enclosure Test gear Systems AC/DC Power A116 Bus C Phase GE 12PVD21B D12-Bus-06 Switch Control 239 Qualification Cap> Dem Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Power All 7 Bus A Phase GE 12PVD21B Dl3-Bus-06 Switch Control 239 Qualification C a p> Dem Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Power All 7 Bus B Phase GE 12PVD21B D13-Bus-06 Switch Control 239 Qualification Support Differential Relay lA-S gear Enclosure Test Cap> Dem Systems AC/DC Power All 7 Bus C Phase GE 12PVD21B Dl3-Bus-06 Switch Control 239 Qualification Support Differential Relay lA-S Enclosure Test Cap> Dem gear Systems AC/DC Power Al18 Bus A Phase GE 12PVD21B D14-Bus-06 Switch Control 239 Qualification Cap>Dem Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Power A118 Bus B Phase GE 12PVD21B D14-Bus-06 Switch Control Qualification Support Differential Relay lA-S Enclosure 239 Test Cap> Dem gear Systems AC/DC Power A118 Bus C Phase GE 12PVD21B D14-Bus-06 Switch Control 239 Qualification Support Differential Relay lA-5 gear Enclosure Test Cap> Dem Systems AC/DC Power D214 Load Center GE 12HFC11B D21-Bus-OS Switch Control 239 Qualification Support Ground Fault lA-S gear Enclosure Test Cap> Dem Systems Page 70of110 El i No. ;vpe J ID 272 2 150G-Protective 11605 Relay 150G-Protective 273 2 11705 Relay 274 2 150G-Protective 11708 Relay 275 2 150G-Protective 11805 Relay 276 2 150G-Protective 11808 Relay 277 2 151N-Protective AG501 Relay 278 2 151N-Protective BG501 Relay 279 2 151N-Protective CGSOl Relay 280 2 151N-Protective DGS01 Relay 281 2 187-llS A Protective Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclos y re I "] Model No. ID M Building AC/DC Power D224 Load Center GE 12HFC11B D22-Bus-05 Switch Control Support Ground Fault lA-S gear Enclosure Systems AC/DC Power D234 Load Center GE 12HFC11B D23-Bus-DS Switch Control Support Ground Fault lA-S Enclosure gear Systems AC/DC Power ESW Pump OCPS48 GE 12HFC11B D23-Bus-08 Switch Control Support Ground Fault lA-S gear Enclosure Systems AC/DC Power D244 Load Center GE 12HFC11B D24-Bus-DS Switch Control Support Ground Fault 1A-S gear Enclosure Systems AC/DC Power ESW Pump DDPS48 GE 12HFC11B D24-Bus-08 Switch Control Support Ground Fault 1A-S gear Enclosu r e Systems AC/DC Power D21 Neutral Westinghous 264C899A D21-Bus-07 Switch Control Support Overcurrent Relay e 01 gear Enclosure Systems AC/DC Power D22 Neutral Westinghous 264C899A D22-Bus-07 Switch Control Support Overcurrent Relay e 01 gear Enclosure Systems AC/DC Power D23 Neut r al westinghous 264C899A Switch Control Support Overcurrent Relay 01 D23-Bus-07 Enclosure e gear Systems AC/DC Power D24 Neutral Westinghous 264C899A D24-Bus-07 Switch Control Support Overcurrent Relay e 01 gear Enclosu r e Systems AC/DC Power AUS Bus A Phase GE 12PVD21B D21-Bus-06 Switch Control Support Differential Relay lA-S gear Enclosure Systems 15C4345-RPT-002 , Rev. 0 Correspondence No.: RS-16-177
: Component Evalu;i t l on Floor Elev. (ft) Basis for Evaluation Capacity Re s ult 239 Qualification Cap> Dem Test 239 Qualification Cap> D e m Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Cap> Dem Test 239 Qualification Test Cap>Dem Qualification 239 Cap> Dem Test 239 Qualification Test Cap> Dem 239 Qualification Test Cap> Dem Page 71 of 110 I I No. Unit II ID T y pe 282 2 187-llSB Protective Relay 283 2 187-USC Protective Relay 187-U6A Protective 284 2 Relay 2 187-116B Protective 285 Relay 2 187-116C Protective 286 Relay 2 187-117A Protective 287 Relay 2 187-117B Protective 288 Relay 289 2 187-117C Protective Relay 290 2 187-118A Protective Relay 2 187-118B Protective 291 Relay Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System Function Manufacturer Model No. ID Type ' Building AC/DC Power AUS Bus B Phase GE 12PVD21B D21-Bus-06 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power AUS Bus C Phase GE 12PVD21B D21-Bus-06 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power AU6 Bus A Phase GE 12PVD21B D22-Bus-06 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power A116 Bus B Phase GE 12PVD21B D22-Bus-06 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power Al16 Bus C Phase GE 12PVD21B D22-Bus-06 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power All 7 Bus A Phase GE 12PVD21B D23-Bus-06 Switch Control Support Differential Relay lA-S Enclosure gear Systems AC/DC Power A117 Bus B Phase GE 12PVD21B D23-Bus-06 Switch Control Support Differential Relay 1A-S Enclosure gear Systems AC/DC Power AU 7 Bus C Phase GE 12PVD21B D23-Bus-06 Switch Control Support Differential Relay 1A-S gear Enclosure Systems AC/DC Power A118 Bus A Phase GE 12PVD21B D24-Bus-06 Switch Control Support Differential Relay 1A-S gear Enclosure Systems AC/DC Power A118 Bus B Phase GE 12PVD21B D24-Bus-06 Switch Control Support Differential Relay 1A-S Enclosure gear Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 I Floor Component Evaluation Elev. (ft) !Iasis for Evaluation Capacltv Result 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test Page 72 of 110 No.: '8 1 [_ f ype 292 2 187-118C Protective Rela y Medium Dll-Bus-07 Voltage 293 1 (152-11507)
Ci r cuit B r eaker Medium 294 1 Dll-Bus-05 Voltage {152-11505)
Circuit Breaker Medium 295 1 D11-Bus-08 Volta g e {152-11508)
Circuit Breaker Medium 296 1 D12-Bus-07 Voltage {152-1160 7) Ci r cuit B r eake r Medium 2 97 1 D12-Bus-05 Voltage (152-11605) Circuit Breaker Medium D12-Bus-08 Voltage 298 1 (152-11608)
Circuit Breaker Medium 299 1 D13-Bus-07 Voltage (152-11707) Ci r cuit Breaker 15C4345-RPT
-002, Rev. 0 Correspondence No.: RS-16-177 Table 8-1: Components Identified for High Frequency Confirmation Component I Enclosure I Building J Floor Component Evaluation
_=1 [ 1 ' Basis , for Evaluation Elev. (ft) Capacitv Result AC/DC Power A118 Bus C Phase GE 12PVD21B D24-Bus-06 Switch Control 239 Qualification Cap> Dem Support Differential Relay l A-S gear Enclosure Test Systems AC/DC Power Dll Diesel Generator ABB/ITE 5HK 350 D11-Bus-07 Switch Control 239 Qualification Cap> Dem Support Circuit Breaker gear Enclosure Test Systems AC/DC Power D114 LC Transformer ABB/ITE 5HK 350 D11-Bus-0 5 Switch Control 239 Qualification Cap> Dem Support Circu it B r eaker gear Enclosure Test Systems AC/DC QA Essential Service Po w e r Water Pump Circuit ABB/ITE 5HK 350 Dll-Bus-08 S w itch Cont r ol 239 Qualification Cap> Dem Su p port Breaker gear Enclosure Test S y stems A C/DC Po w er D12 Diesel Generator ABB/ITE 5HK 350 D12-Bus-0 7 S w itch Control 239 Qualification Cap> Dem Support Circuit Breaker gear Enclosure Test S y stems AC/DC Power D124 LC Transformer ABB/ITE 5 H K 350 012-Bus-05 S w itch Contro l Qualification Support Ci r cuit Breaker Enclosu r e 239 Cap> Dem gear Test S y stems AC/DC OB Essential Service Power S w itch Control Qualification Support Water Pump Circuit ABB/ITE 5HK 350 D12-Bus-0 8 Enclosure 239 Cap> Dem Breaker gear Test Systems AC/DC Power Dl3 Diesel Generator ABB/ITE 5HK 350 013-Bus-0 7 Switch Control Qualification Support Circu i t Breaker Enclosure 239 Cap> Dem gear Test S y stems Page 73 of 110 No. Unit ID Type i Medium DB-Bus-OS Voltage 300 1 (152-11705)
Circuit Breaker Medium D14-Bus-07 Voltage 301 1 (152-11807)
Circuit Breaker Medium D14-Bus-05 Voltage 302 1 (152-11805)
Circuit Breaker Medium D21-Bus-07 Voltage 303 2 (152-11507)
Circuit Breaker Medium D21-Bus-OS Voltage 304 2 (152-11505)
Circuit Breaker Medium D22-Bus-07 Voltage 305 2 (152-11607) Circuit Breaker Medium 2 D22-Bus-OS Voltage 306 (152-11605)
Circuit Breaker Medium 2 D23-Bus-07 Voltage 307 {152-11707)
Circuit Breaker Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System Function 'Manufacturer Model 1 No. ID Type Building AC/DC Power OB4 LC Transformer ABB/ITE 5HK 350 DB-Bus-OS Switch Contro l Support Circuit Breaker gear Enclosure Systems AC/DC Power D14 Diesel Generator ABB/ITE SHK 350 D14-Bus-07 Switch Control Circuit Breaker Enclosure Support gear Systems AC/DC Power D144 LC Transformer ABB/ITE SHK 350 D14-Bus-OS Switch Control Support Circuit Breaker gear Enclosure Systems AC/DC Power D21 Diesel Generator ABB/ITE SHK 350 D21 Bus-07 Switch Contro l Circuit Breaker Enclosure Support gear Systems AC/DC Power D214 LC Transformer ABB/ITE SHK 350 D21-Bus-OS Switch Control Support Circuit Breaker Enclosure gear Systems AC/DC Power D22 Diesel Generator ABB/ITE SHK 350 D22-Bus-07 Switch Control Circuit Breaker Enclosure Support gear Systems AC/DC Power D224 LC Transformer ABB/ITE SHK 350 D22-Bus-OS Switch Control Support Circuit Breaker Enclosure gear Systems AC/DC Power D23 Diesel Generator ABB/ITE SHK 350 D23-Bus-07 Switch Control Support Circuit Breaker gear Enclosure Systems 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Floor Component Evaluation Elev. (ft) Basis for Evaluation caoacltv Result 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test Page 74of110 I ---Unit* j" I No. 1 ID il'ype . Medium D23-Bus-05 Voltage 308 2 (152-11705)
Circuit Breaker Medium D23-Bus-08 Voltage 309 2 (152-11708)
Circuit Breaker Medium D24-Bus-07 Voltage 310 2 (1S2-11807)
Circuit Breaker Medium D24-Bus-05 Voltage 311 2 (152-11805)
Circuit Breaker Medium 2 D24-Bus-08 Voltage 312 (152-11808)
Circuit Breaker T2A (1ETB-Control 313 1 AG501) Relays T2B (1ETB-Control 314 1 AG501) Relays 315 1 T2A (1ETB-Control BG501) Relays T2B (lETB-Control 316 1 BG501) Relays Table B-1: Components Identified for High Frequency Confirmation Enclosure I -Building System Manufacturer Model No. ID Type AC/DC Power D234 LC Transformer ABB/ITE 5HK 350 D23-Bus-05 Switch Control Support Circuit Breaker gear Enclosure Systems AC/DC OC Essential Service Power Switch Control Water Pump Circuit ABB/ITE 5HK 350 D23-Bus-08 Support Breaker gear Enclosure Systems AC/DC Power D24 Diesel Generator ABB/ITE 5HK 350 D24-Bus-07 Switch Control Support Circuit Breaker Enclosure gear Systems AC/DC Power D244 LC Transformer ABB/ITE 5HK 350 D24-Bus-05 Switch Control Support Circuit Breaker Enclosure gear Systems AC/DC OD Essential Service Power Water Pump Circuit ABB/ITE 5HK 350 D24-Bus-08 Switch Contro l Support Enclosure Breaker gear Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 1ETB-Control D i esel Support 004 AG501 Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 1ETB-Control Diesel Support 004 AG501 Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 1ETB-Control Diesel Support 004 BG501 Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B lETB-Control Diesel Support 004 BG501 Cab. Generator Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Component Evaluation Floor I ' Elev. (ft) j Basis for Evaluation Capacity Result L -239 Qualification Cap> Dem Test Qualification 239 Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 239 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test Page 75 of 110 No. I Unit I ID i:vpe T2A (lETB-Control 317 1 CGSOl) Relays T2B (lETB-Control 318 1 CGSOl) Relays T2A (lETB-Control 319 1 DGSOl) Relays 320 1 T2B (lETB-Control DGSOl) Relays 2 T2A (2ETB-Control 321 AGSOl) Relays 2 T2B (2ETB-Control 322 AGSOl) Relays 323 2 T2A (2ETB-Control BGSOl) Relays 2 T2B (2ETB-Control 324 BGSOl) Relays 325 2 T2A (2ETB-Control CGSOl) Relays T2B (2ETB-Control 326 2 CGSOl) Relays Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System I I Function Man uf acturer Model No. ID Type Building AC/DC Power Overcrank Relay Tyco ETR14D3B lETB-Control Diesel Support 004 CGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B lETB-Control Diesel Support 004 CGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Amerace ETR14D3B lETB-Control Diesel Support 002 DGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Amerace ETR14D3B lETB-Control Diesel Support 002 DGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 AGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 2ETB Control Diesel Support 004 AGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 BGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 BGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 CGSOl Cab. Generator Systems AC/DC Power Overcrank Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 CGSOl Cab. Generator Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor I Component Evaluation Elev. (ft) I Basis for Evaluation Capacltv Result 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualificat i on Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap>Dem Test 217 Qualification Test Cap> Dem 217 Qualification Test Cap> Dem 217 Qualification Cap> Dem Test Page 76 of 110 r No. I' I Unlt j ID Type T2A (2ETB-Control 327 2 DG501) Relays T2B (2ETB-Control 328 2 DG501) Relays T3A (1ETB-Control 329 1 AGSOl) Relays 330 T3A (1ETB-Control 1 BGSOl) Relays 331 T3A (lETB-Control 1 CGSOl) Relays T3A (lETB-Control 332 1 DGSOl) Relays 333 2 T3A (2ETB-Control AG501) Relays 334 2 T3A (2ETB-Control BG501) Relays 335 2 T3A (2ETB-Control CGSOl) Relays 336 2 T3A (2ETB-Control DGSOl) Relays Table B-1: Components Identified for High Frequency Confirmation Component Enclosure
-System
* l Function 1 Manufacturer Model No. ID Type BulldJng --AC/DC Power Overcrank Relay Amerace ETR14D3B 2ETB-Control Diesel Support 002 DGS01 Cab. Generator Systems AC/DC Power Overcrank Relay Amerace ETR14D3B 2ETB-Control Diesel Support 002 DG501 Cab. Generator Systems AC/DC Power High Speed Relay Tyco ETR14D3B lETB-Control Diesel Support 004 AGSOl Cab. Generator Systems AC/DC Power High Speed Relay Tyco ETR14D3B lETB-Control Diesel Support 004 BGSOl Cab. Generator Systems AC/DC Power High Speed Relay Tyco ETR14D3B 1ETB-Control Diesel Support 004 CGSOl Cab. Generator Systems AC/DC Power High Speed Relay Amerace ETR14D3B lETB-Control Diesel Support 002 DGSOl Cab. Generator Systems AC/DC Power High Speed Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 AGSOl Cab. Generator Systems AC/DC Power High Speed Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 BGSOl Cab. Generator Systems AC/DC Power High Speed Relay Tyco ETR14D3B 2ETB-Control Diesel Support 004 CGSOl Cab. Generator Systems AC/DC Power High Speed Relay Amerace ETR14D3B 2ETB-Control Diesel Support 002 DGSOl Cab. Generator Systems 1SC4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Floor.-Component Evaluation Elev. {ft) Basls*for Evaluation capacity Result 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Test Cap> Dem 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap >Dem Test Page 77of110 J I -No. Unit I ID Type -337 1 Dll-SE Control Relays 338 1 D12-SE Control Relays 339 D13-SE Control 1 Relays 340 1 D14-SE Control Relays Control 341 2 D21-SE Relays 342 D22-SE Control 2 Relays D23-SE Control 343 2 Relays D24-SE Control 344 2 Relays 345 Dll-CPl Control 1 Relays 346 1 Dll-CP2 Control Relays 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Component Evaluation
--Floor I Building I Basls*for Evaluation System Function Manufacturer Model No. ID Type Elev. (ft)
* Capacity Result -AC/DC Power Emergency Stop Amerace 7024PE lETB-Control Diesel 217 GERS Cap> Dem Support Relay AGSOl Cab. Generator Systems AC/DC Power Emergency Stop 7024PE lETB-Control Diesel 217 GERS Cap>Dem Support Relay Amerace BGSOl Cab. Generator Systems AC/DC Power Emergency Stop Amerace 7024PE lETB-Control Diesel 217 GERS Cap> Dem Support Relay CGSOl Cab. Generator Systems AC/DC Power Emergency Stop Amerace 7024PE lETB-Control Diesel 217 GERS Cap> Dem Support Relay DGSOl Cab. Generator Systems AC/DC Power Emergency Stop Amerace 7024PE 2ETB-Control Diesel 217 GERS Cap> Dem Support Relay AGSOl Cab. Generator Systems AC/DC Power Emergency Stop Amerace 7024PE 2ETB-Control Diesel 217 GERS Cap> Dem Support Relay BGSOl Cab. Generator Systems AC/DC Power Emergency Stop Amerace 7024PE 2ETB-Control Diesel 217 GERS Cap> Dem Support Relay CGSOl Cab. Generator Systems AC/DC Power Emergency Stop Amerace 7024PE 2ETB-Control Diesel 217 GERS Cap> Dem Support Relay DGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE Jl3P3012 lETB-Control Diesel 217 GERS Cap> Dem Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 lETB-Control Diesel 217 GERS Cap> Dem Support Pressure Low Relay AGSOl Cab. Generator Systems Page 78of110 EJ[ -No *. J[ ID Type --347 1 D11-CP3 Control Relays 348 1 Dll-CTl Control Rela y s 349 1 Dll-CT2 Control Relays 350 1 D11-CT3 Control Relays 351 1 Dll-OPl Control Relays 352 1 Dll-OP2 Control Relays 353 1 Dll-OP3 Control Rela y s 354 1 Dll-OTl Control Relays 355 1 Dl1-0T2 Con t rol Rela y s 356 1 Dl1-0T3 Control Rela y s 15C4345-RPT-002 , Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure
:I Component Evaluation Floo;J ]'i System
--=i I Basis fo r Evaluation Model No. ID Capacity Result -AC/DC Power Jacket Cooling ITE J13P3012 lETB-Control Diesel 217 Support Pressure Low Relay AGSOl Cab. Generator GERS Cap> Dem Systems AC/DC Power Jacket Coolant IT E J13P3012 lETB-Control Diesel 217 Support Temperature Relay AGSOl Cab. Generator GERS Cap> Dem Systems AC/DC Power Jacket Coolant ITE J13P3012 lETB-Control Diesel 217 GERS Support Temperature Relay AG501 Cab. Generator Cap> Dem Systems AC/DC Power Jacket Coolant ITE J13P3012 lETB-Control Diesel 217 GERS Support Temperature Relay A G501 Cab. Generator Cap> Dem Systems AC/DC Power Lube Oil Pressure ITE J13P3012 lETB-Control Diesel Support Low Relay AG501 Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Lube Oil Pressure ITE Jl3P3012 lETB-Control Diesel 217 Support Low Relay AG501 Cab. Generator GERS Cap> Dem Systems AC/DC Power Lube Oil Pressure ITE J13P3012 lETB-Control Diesel 217 Support Low Relay AG501 Cab. Generator GERS Cap>Dem Systems A C/DC Power Lube Oil High ITE J13P3012 lETB-Control Diesel 217 Support Temperature Relay AG501 Cab. Generator GERS Cap> Dem Systems AC/DC Power Lube Oil High ITE J13P3012 lETB-Control Diesel Support Temperature Relay AGSOl Cab. Generato r 217 GERS Cap> Dem Systems AC/DC Po w er Lube Oil High ITE J13P3012 lETB-Control Diesel 217 GERS Support Temperature Relay AGSOl Cab. Gene r ato r Cap> Dem Systems Page 79 of 110 No. 'i EJ 1* 357 1 Dll-SDR Control Relays 358 1 Dll-SFR Control Relays 359 1 D12-CP1 Control Relays 360 1 D12-CP2 Control Relays 361 1 D12-CP3 Control Relays 362 1 D12-CT1 Control Relays 363 1 D12-CT2 Control Relays 364 1 D12-CT3 Control Relays 365 1 D12-0P1 Control Relays 366 1 D12-0P2 Control Relays 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Compone!lt rw. '_ .. I Building j i Floor J Component Evaluation
,_]
I I Basis for Evaluation ID Elev. (ft) caoacltv Result -------' AC/DC Power Shutd o wn Relay ITE J13P30 1 2 lETB-Contro l Diesel 217 Support AG501 Cab. Generator GERS Cap> Dem Systems AC/DC Power Start F a ilure Relay ITE J13P3012 lETB-Control Diesel 217 GERS Cap>Dem Support AGSOl Cab. Generator Systems AC/DC Power Jac k et Cooling ITE J13P3012 lETB-Contro l Diesel 217 Support Pressure Low Relay BG501 Cab. Generator GERS Cap> Dem Systems AC/DC Power Jacket Cool i ng ITE J13P3012 lETB-Control Diesel 217 Support Pressure Low Relay BG501 Cab. Generator GERS Cap> Dem Systems AC/DC Power Jacket Cooling ITE J13P30 1 2 lETB-Control Diesel 217 Support Pressure Low Relay BG501 Cab. Generator GERS Cap> Dem Systems AC/DC Power Jac ke t Coolant lETB-Control D i esel Support Temp e rature Relay I T E J13P30 1 2 BGSOl Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Jac k et Coolant ITE Jl3P3012 lETB-Control Diesel Support Temperature Relay BG501 Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Ja ck et Coolant lETB-Control Dies el Support Temperature Relay ITE J13P30 1 2 BG501 Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Lube Oil Pressure lETB-Control Diesel Support Low R e lay I T E J13P3012 BG501 Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Lube Oil Pressure lETB-Control Diesel Support Low R e lay ITE J13P30 1 2 BG501 Cab. 217 GERS Cap> Dem Generator Systems Page 80of110 B[ No. Type D12-0P3 Control 367 1 Relays Control 368 1 D12-0Tl Relays 369 1 D12-0T2 Control Relays 370 1 D12-0T3 Control Relays 371 1 D12-SDR Control Relays 372 1 D12-SFR Control Relays 373 1 D13-CP1 Control Relays 374 1 D13-CP2 Control Relays 375 1 D13-CP3 Control Relays 376 1 D13-CT1 Control Relays Table B-1: Components Identified for High Frequency Confirmation Component Enclosure I [Manufacturer l [ M:ci el No. j 1 ID 1-1 Building AC/DC Power Lube Oil Pressure ITE J13P3012 lETB-Control Diesel Support Low Relay BGSOl Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 lETB-Control Diesel Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Power Lube Oil High I TE J13P3012 lETB-Control Diesel Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 lETB-Control Diesel Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Power Shutdown Relay I TE J13P3012 lETB-Control Diesel Support BGSOl Cab. Generator Systems AC/DC Power Start Failure Relay ITE J13P3012 lETB-Control Diesel Support BGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 lETB-Control Diesel Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 lETB-Control Diesel Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 lETB-Control Diesel Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Coolant ITE J13P3012 lETB-Control Diesel Support Temperature Relay CGSOl Cab. Generator Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Component Evaluation Elev. (ft) Basis fo r Evaluation CapacltV Result '* 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem Page 81 of 110 No. I 8 1 , ID II ] 377 D13-CT2 Control 1 Relays 378 1 D13-CT3 Control Relays 379 D13-0P1 Control 1 Relay s 380 1 D13-0P2 Control Relays 381 1 D13-0P3 Control Relays 382 1 Dl3-0T1 Control Relays 383 1 Dl3-0T2 Control Relays 384 1 Dl3-0T3 Control Relays 385 1 Dl3-SDR Control Relays 386 1 013-SFR Control Relays 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure 8 Floor Component Evaluat i on
-* J r Manufacturer 1 Building 1 Elev. (ft) Basis for Evaluation ID Capacity Result AC/DC Power Jacket Coolant ITE J13P3012 lETB-Control Diesel 217 GERS Support Temperature Relay CGSOl Cab. Generator Cap> D ern Systems AC/DC Power Jacket Coolant I T E J13P3012 lETB-Control Diesel 217 GERS Support T e mperature Relay CGSOl Cab. Generator Cap> Dern Systems AC/DC Power Lube Oil Pressure ITE J13P3012 lETB-Control Diesel 217 GERS Support Low Relay CGSOl Cab. Generator Cap> Dern S y stems AC/DC Power Lube O il Pressure I T E J13P3012 lETB-Control Diesel 217 GERS Support Low Relay CGSOl Cab. Generator Cap> Dern Systems AC/DC Power Lube O il Pressure ITE J13P30 1 2 lETB-Control Diesel 217 GERS Support Low Re l ay CGSDl Cab. Generator Cap> D e m Systems AC/DC Power Lube Oil High IT E J13P30 1 2 lETB-Contro l Diesel 217 GE R S Support T e mp e rature Relay CGSOl Cab. Generator Cap> Dern Systems AC/DC Power Lube Oil High I TE J13P3012 lETB-Contro l Diesel Support Temperature Relay CGSOl Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Lube O il High ITE J13P3012 lETB-Control Diesel 217 Support Temperature Relay CGSOl Cab. Generator GERS Cap> De rn Systems AC/DC Power Shutdown Relay ITE J13P30 1 2 lETB-Control Diesel 217 Support CGSOl Cab. Generator G ER S Cap> Dem Systems AC/DC Power Start Fai l ure Relay ITE J13P3012 lETB-Control Diesel Support CGSOl Cab. Generator 217 GERS Cap> Dem Systems Page 82of110 No. EJ 387 1 388 1 389 1 390 1 391 1 392 1 393 1 394 1 395 1 396 1 15C4345-RPT
-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
--Component r . Enclosure I r Floor Component
_;valuat i on [ 10 _ J l J
==:JI Manufacturer 10 [ -Elev. (ft) Basls*for Evaluation Mo<!e l 1 No. Capacltv 1 Result A C/DC D14-CP1 Co n trol Power Jacket Cooling ITE J13P3012 l ETB-Control Diesel 217 GERS Cap> Dem Rela y s Support Pr e ssure Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling ITE Jl3P3012 lETB-Control Diesel 217 GERS Cap> Dem D14-CP2 Relays Support Pre s sure Low Re l ay DGSOl Cab. Generator Systems AC/DC D14-CP3 Con t rol Power Jacket Cooling ITE J13P3012 lETB-Control Diesel 217 GERS Cap> Dem Relays Support Pressure Low Relay DGSOl Cab. Generator Systems AC/DC D14-CT1 Control Power Jac k et Coolant ITE J13P3012 lETB-Control Diesel 217 GERS Cap> Dem Relays Support Temp e rature Relay DGSOl Cab. Generator Systems AC/DC D14*CT2 Control Power Jac k et Coo l ant ITE J13P3012 lETB-Contro l Diesel 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems AC/DC D14-CT3 Control Power Jacket Coolant ITE J13P30 1 2 lETB-Control D i esel 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems AC/DC D14-0P1 Control Power Lube Oil Pressure I T E J 13P3012. lETB-Control Diesel 217 GERS Cap>Dem Relays Support Low R e lay DGSOl Cab. Generator Systems AC/DC D14-0P2 Control Power Lube O il Pressure ITE J13P3012 lETB-Cont r ol Diesel Relays Support Low R el ay DGSOl Cab. Generator 217 GERS Cap> Dem Systems AC/DC D14-0P3 Contro l Power Lube Oil P r essure I T E J13P3012 lETB-Control Diesel 217 Relays Support Low R e lay DGSOl Cab. Gene r ator GERS Cap> Dem Systems A C/DC D14-0T1 Control Power Lube Oil High ITE lETB-Con t rol Diesel Relays Support Temperature Relay J13P3012 DGSOl Cab. Generator 2 1 7 GERS Cap> Dem Systems Page 83 of 110 
. *-No. Unit j ID T.ype --D14-0T2 Control 397 1 Relays 398 1 D14-0T3 Control Relays D14-SDR Control 399 1 Relays 400 1 D14-SFR Control Relays 2 D21-CP1 Control 401 Relays 2 D21-CP2 Control 402 Relays 403 2 D21-CP3 Control Relays 2 D21-CT1 Control 404 Relays 405 2 D21-CT2 Control Relays 406 2 D21-CT3 Control Relays Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System Function Manufacturer Model'No. ID Type Building -AC/DC Power Lube Oil High ITE J13P3012 lETB-Control Diesel Support Temperature Relay DGSOl Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 lETB-Control Diesel Support Temperature Relay DGSOl Cab. Generator Systems AC/DC Power Shutdown Relay ITE J13P3012 lETB-Control Diesel Support DGSOl Cab. Generator Systems AC/DC Power Start Failure Relay ITE J13P3012 lETB-Control Diesel Support DGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 2ETB-Control Diesel Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE Jl3P3012 2ETB-Control Diesel Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 2ETB-Control Diesel Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel Support Temperature Relay AGSOl Cab. Generator Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel Support Temperature Relay AGSOl Cab. Generator Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel Support Temperature Relay AGSOl Cab. Generator Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Component Evaluation Floor Elev. (ft) Basis for Evaluation Capacity Result 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap>Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem Page 84of110 Table B-1: Components Identified for High Frequency Confirmation 8 1 "-" I Enclosure
-Component No.: ID_ J[ rv i.] I r 11 N;i [ Building ID A C/DC Control Powe r Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel 407 2 D21-0P1 Rela y s Support Low Relay AGSOl Cab. Gene r ato r S y stems A C/DC Con t rol Po w e r Lube Oil P r essure ITE J13P3012 2ETB-Control Diesel 408 2 D 2 1-0P2 Relays Support Low Relay AGSOl Cab. Generator S y stems A C/DC 4 09 D21-0P3 Control Power Lube Oil Pressure ITE J13P3012 2ETB-Cont r ol Diesel 2 Rela y s Support Lo w Relay AGSOl Cab. Gene r a t o r S y stems AC/DC D 21-0Tl Con t rol Po w er Lube Oil High ITE J13 P 3012 2ETB-Control Diesel 410 2 Rela y s Support Temperature Relay AGSOl Cab. Gene r ato r Systems A C/DC D21-0T2 Co ntr ol Power Lube Oil High ITE J13P3012 2ETB-Control Diesel 411 2 Rel a ys Support Temp e ratu r e Relay AGSOl Cab. Generato r Systems A C/DC 412 2 D21-0T3 Co n trol Powe r Lube Oil High ITE J13P3012 2ETB-Control Diesel Relays Support Temperature Relay AGSOl Cab. Generator S y stems AC/DC 4 13 2 D21-SDR Con t rol Power Shutdown Relay ITE J13P3012 2ETB-Cont r ol Diesel Rel ay s Support AGSOl Cab. Generato r Systems AC/DC D 2 1-SF R Con t rol Po w er Start Failure Relay ITE J13P3012 2ETB-Control Diesel 4 14 2 Rela y s Support AGSOl Cab. Generato r S y stems A C/DC 2 D22-CP1 Con tr ol Po w e r Jacket Cooling ITE J13P3012 2ETB-Control Diesel 415 Relays Support Pressure Lo w Relay BGSOl Cab. Gene r ator S y stems A C/DC D22-CP2 Con t rol Po w er Jacket Cooling ITE J13P3012 2ETB-Control Diesel 416 2 Rela y s Support Pressure Low Relay BGSOl Cab. Gene r ato r S y stems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation I Elev. (ft) Basis for Evaluation Capacity Result 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem Page 85of110 8 1 No.' , 1 0 417 2 D22-CP3 Control Rel a ys 418 2 D22-CT1 Control Relays 419 2 D22-CT2 Control Relays 420 2 D22-CT3 Control Relays 421 2 D22-0P1 Control Relays 422 2 D22-0P2 Control Relays 423 2 D22-0P3 Control Rela y s 424 2 D22-0T1 Control Relays 425 2 D22-0T2 Control Relays 426 2 D22-0T3 Control Relays 15C4345-RPT
-002 , Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
-Enclosure Component Floor 1' Component Evaluat i on OM * ] [ Building J Elev. (ft) Basis fo r Evaluation ID Ca p acity Re s ult A C/DC Po w er Jacket Cooling ITE J13P3012 2ETB-Control Diesel 2 1 7 GERS Cap> Dem Support Pressure Low Relay BGSOl Cab. Generator Systems A C/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel 217 GERS Support Temperature Relay BGSOl Cab. Generator Cap> Dem Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel 217 Support Temperature Relay BGSOl Cab. Generator GERS Cap> Dem Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel 217 Support Temperature Relay BGSOl Cab. Generator GERS Cap> Dem Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel 217 Support Low Relay BGSOl Cab. Generator GERS Cap> Dem Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel Support Low Relay BGSOl Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel Support Low Relay BGSOl Cab. Generator 217 GERS Cap> Dem S y stems AC/DC Power Lube Oil High 2ETB-Control Diesel Support Temperature Relay ITE J13P3012 BGSOl Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Lube Oil High ITE J13P3012 2ETB-Control Diesel Support Temperature Relay BGSOl Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Lube Oil High 2ETB-Control Diesel Support Temperature Relay ITE J13P3012 BGSOl Cab. Genera t or 217 GERS Cap> Dem Systems Page 86 of 110 
-No. Unit ID Type 2 D22-SDR Control 427 Relays 428 2 D22-SFR Control Relays 2 D23-CP1 Control 429 Relays 2 D23-CP2 Control 430 Relays 431 2 D23-CP3 Control Relays 432 2 D23-CT1 Control Relays 433 2 D23-CT2 Control Relays 434 2 D23-CT3 Control Relays 435 2 D23-0Pl Control Relays 436 2 D23-0P2 Control Relays Table B-1: Components Identified for High Frequency Confirmation component Enclosure I Building System Function Manufacturer Model No. ID Type AC/DC Power Shutdown Relay ITE J13P3012 2ETB-Control Diesel Support BGSOl Cab. Generator Systems AC/DC Power Start Failure Relay ITE J13P3012 2ETB-Control Diesel Support BGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 2ETB-Control Diesel Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 2ETB-Control Diesel Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Cooling ITE J13P3012 2ETB-Control Diesel Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Power Jacket Coolant ITE Jl3P3012 2ETB-Control Diesel Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel Support Low Relay CGSOl Cab. Generator Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel Support Low Relay CGSOl Cab. Generator Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Basis for Evaluation Elev. (ft) Capacity Result 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem Page 87 of 110 I No. Unit I ID Type 437 2 D23-0P3 Control Relays 438 2 D23-0Tl Control Relays 439 2 D23-0T2 Control Relays 440 2 D23-0T3 Control Relays 441 2 D23-SDR Control Relays 442 2 D23-SFR Control Relays 443 2 D24-CP1 Control Relays 2 D24-CP2 Control 444 Relays 445 2 D24-CP3 Control Relays 446 2 D24-CT1 Control Relays 15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure BuHding j Component Evaluation Floor . 'Basis for Evaluation System Function Manufacturer ModeiNo. ID Type I Elev. {ft) Capacltv Result AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel 217 GERS Cap> Dem Support Low Relay CGSOl Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 2ETB-Control Diesel 217 GERS Cap> Dem Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 2ETB-Control Diesel 217 GERS Cap> Dem Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 2ETB-Control Diesel 217 GERS Cap> Dem Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Power Shutdown Relay ITE Jl3P3012 2ETB-Control Diesel 217 GERS Support CGSOl Cab. Generator Cap> Dem Systems AC/DC Power Start Failure Relay ITE J13P3012 2ETB-Control Diesel 217 Support CGSOl Cab. Generator GERS Cap> Dem Systems AC/DC Power Jacket Cooling ITE J13P3012 2ETB-Control Diesel 217 Support Pressure Low Relay DGSOl Cab. Generator GERS Cap>Dem Systems AC/DC Power Jacket Cooling ITE Jl3P3012 2ETB-Control Diesel Support Pressure Low Relay DGSOl Cab. Generator 217 GERS Cap> Dem Systems AC/DC Power Jacket Cooling ITE J13P3012 2ETB-Control Diesel 217 Support Pressure Low Relay DGSOl Cab. Generator GERS Cap> Dem Systems AC/DC Power Jacket Coolant ITE 2ETB-Control Diesel Support Temperature Relay J13P3012 DGSOl Cab. Generator 217 GERS Cap> Dem Systems Page 88 of 110 I Unit r* -No. I ' 1 10 TvPe 2 D24-CT2 Control 447 Relays 448 2 D24-CT3 Control Relays 2 D24-0P1 Control 449 Relays 450 2 D24-0P2 Control Relays 2 D24-0P3 Control 451 Relays 2 D24-0T1 Control 452 Relays 453 2 D24-0T2 Control Relays 2 D24-0T3 Control 454 Relays 455 2 D24-SDR Control Relays 456 2 D24-SFR Control Relays Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Building System Function Manufacturer
*Model No. ID Type I I AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel Support Temperature Relay DG501 Cab. Generator Systems AC/DC Power Jacket Coolant ITE J13P3012 2ETB-Control Diesel Support Temperature Relay DG501 Cab. Generator Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel Support Low Relay DG501 Cab. Generator Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel Support Low Relay DG501 Cab. Generator Systems AC/DC Power Lube Oil Pressure ITE J13P3012 2ETB-Control Diesel Support Low Relay DG501 Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 2ETB-Control Diesel Support Temperature Relay DG501 Cab. Generator Systems AC/DC Power Lube Oil High ITE J13P3012 2ETB-Control Diesel Support Temperature Relay DG501 Cab. Generator Systems AC/DC Power Lube Oil High ITE Jl3P3012 2ETB-Control Diesel Support Temperature Relay DG501 Cab. Generator Systems AC/DC Power Shutdown Relay ITE Jl3P3012 2ETB-Control Diesel Support DG501 Cab. Generator Systems AC/DC Power Start Failure Relay ITE J13P3012 2ETB-Control Diesel Support DG501 Cab. Generator Systems 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Component Evaluation Floor I !Jaslsfor Evaluation I Elev. (ft) Capacity Result 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap>Dem 217 GERS Cap> Dem 217 GERS Cap> Dem 217 GERS Cap> Dem Page 89of110 
!Jnit -No. ID Type '--457 1 Dll-EOS Process Switch 458 1 DlZ-EOS Process Switch Process 459 1 D13-EOS Switch Process 460 1 D14-EOS Switch Process 461 2 D21-EOS Switch 2 D22-EOS Process 462 Switch 463 2 D23-EOS Process Switch D24-EOS Process 464 2 Switch 465 1 TSH-GA-Process llOA-1 Switch TSH-GA-Process 466 1 110A-2 Switch Table B-1: Components Identified for High Frequency Confirmation Component Enclosure System Function Manufacturer Model No. ID I Type Building AC/DC Power Engine Overspeed Honeywell BZE6-1A-G501 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Engine Overspeed Honeywell BZE6-1B-G501 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Engine Overspeed Honeywell BZE6-1C-G501 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Engine Overspeed Honeywell BZE6-1D-G501 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Engine Overspeed Honeywell BZE6-2A-G501 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Engine Overspeed Honeywell BZE6-2B-GS01 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Engine Overspeed Honeywell BZE6-2C-G501 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Engine Overspeed Honeywell BZE6-2D-G501 Diesel Diesel Support Switch 2RN7 Engine Generator Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J 1A-G501 Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J 1A-G501 Diesel Diesel Support Temperature Switch Engine Generator Systems 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Elev. (ft) Basis for Evaluation capacltv Result 217 EPRI HF Test Cap> Dem 217 EPRI HF Test Cap> Dem 217 EPRI HF Test Cap> Dem 217 EPRI HF Test Cap> Dem 217 EPRI HF Test Cap> Dem 217 EPRI HF Test Cap> Dem 217 EPRI HF Test Cap> Dem 217 EPRI HF Test Cap> Dem 217 Qualification Test Cap> Dem 217 Qualification Cap> Dem Test Page 90of110 
' No. C l [. fype l ID 467 1 TSH-GA-Process llOA-3 Switch TSH-GA-Process 468 1 101A Switch 469 1 TSH-GA-Process 102A Switch 470 1 TSH-GA-Process 103A Switch 471 1 TSH-GA-Process llOB-1 Switch 472 1 TSH-GA-Process llOB-2 Switch 473 1 TSH-GA-Process llOB-3 Switch 474 1 TSH-GA-Process 101B Switch 475 1 TSH-GA-Process 102B Switch 476 1 TSH-GA-Process 103B Switch 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component r Enclosu re _J I Component Evaluation Floor I Manufacturer I I: Mooel No. Elev. (ft) Basis for Evaluation Function Capacity Result AC/DC Power Jacket Coolant Allen Bradley 837-V3J lA-GSOl Diesel Diesel 217 Qualification Cap> Dem Support Temperature Switch Engine Generator Test Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J lA-GSOl Diesel Diesel 217 Qualification Support Temperature Switch Engine Generator Test Cap> Dem Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J lA-GSOl Diesel Diesel 217 Qualification Support Temperature Switch Engine Generator Test Cap> Dem Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J lA-GSOl Diesel Diesel 217 Qualification Support Temperature Switch Engine Generator Test Cap> Dem Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J lB-GSOl Diesel Diesel Qualification Support Temperature Swi t ch Engine Generator 217 Test Cap>Dem Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J Diesel Diesel Qualification Support Temperature Switch lB-GSOl Engine Generator 217 Test Cap >Dem Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J 10-GSOl Diesel Diesel 217 Qualification Support Temperature Switch Engine Generator Test Cap>Dem Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J Diesel Diesel Qualification Support Temperature Switch lB-GSOl Engine Generator 217 Test Cap> Dem Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J Diesel Diesel Qualification lB-GSOl 217 Cap> Dem Support Temperature Switch Engine Generator Test Systems AC/DC Power Lube Oil High Allen Bradley Diesel Diesel Qualification Support Temperature Switch 837-V3J lB-GSOl Engine Generator 217 Test Cap> Dem Systems Page 91 of 110 
' l j ---No.1 1 10
-477 1 TSH-GA-Process llOC-1 Switch TSH-GA-Process 478 1 llOC-2 Switch 479 1 TSH-GA-Process llOC-3 Switch 480 1 TSH-GA-Process lOlC Switch 481 1 TSH-GA-Process 102C Switch 482 1 TSH-GA-Process 103C Switch 483 1 TSH-GA-Process llOD-1 Switch 484 1 TSH-GA-Process llOD-2 Switch 485 1 TSH-GA-Process llOD-3 Switch 486 1 TSH-GA-Process 101D Switch Table B-1: Components Identified for High Frequency Confirmation Enclosure
-, Building System Function Man uf acturer Model No. ID Type -AC/DC Power Jacket Coolant Allen Bradley 837-V3J lC-GSOl Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J lC-GSOl Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J lC-GSOl Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J lC-GSOl Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J lC-GSOl Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J lC-GSOl Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J lD-GSOl Diesel Diesel Support Temperature Switch Engine Generator Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J Diesel Diesel Support Temperature Switch lD-GSOl Engine Generator Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J Diesel Diesel Support Temperature Switch lD-GSOl Engine Generator Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J Diesel Diesel Support Temperature Switch lD-GSOl Engine Generator Systems 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Basis for Evaluation Elev. (ft) Capacity Result 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Cap> Dem Test 217 Qualification Test Cap> Dem 217 Qualification Test Cap> Dem 217 Qualification Test Cap> Dem 217 Qualification Test Cap >Dem Qualification 217 Test Cap> Dem Qualification 217 Test Cap> Dem Qualification 217 Test Cap> Dem Page 92 of 110 No. EJ 487 1 488 1 489 2 490 2 491 2 492 2 493 2 494 2 495 2 496 2 15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component I Enclosure
=i Building al --Component Evaluation Floor ! = ID*-] I T , ype s-, 11 No.1 Elev. (ft) I Basis for Evaluation ID Capacity Result AC/DC TSH-GA-Process Power Lube Oil High Allen Bradley 837-V3J lD-GSOl Diesel Diesel 217 Qualification Cap> Dem 102D Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Lube Oil High Allen Bradley 837-V3J lD-GSOl Diesel Diesel 217 Qualification Cap> Dem 103D Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Jacket Coolant Allen Bradley 837-V3J 2A-G501 Diesel Diesel 217 Qualification Cap> Dem 210A-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Jacket Coolant Allen Bradley 837-V3J 2A-G501 Diesel Diesel 217 Qualification Cap> Dem 210A-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Jacket Coolant Allen Bradley 837-V3J 2A-GS01 Diesel Diesel 217 Qualification Cap> Dem 210A-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Lube O il High Allen Bradley 837-V3J 2A-G501 Diesel Diesel 217 Qualification Cap> Dem 201A Switch Support Temp e rature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Lube Oil High Allen Bradley 837-V3J 2A-G501 Diesel Diesel 217 Qualification Cap>Dem 202A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Lube Oil High Allen Bradley 837-V3J 2A-G501 Diesel Diesel 217 Qualification Cap> Dem 203A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Jacket Coolant Allen Bradley 837-V3J 2B-G501 Diesel Diesel 217 Qualification Cap> Dem 2106-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Jacket Coolant Allen Bradley 837-V3J 2B-G501 Diesel Diesel 217 Qualification Cap> Dem 2108-2 Switch Support Temperature Switch Engine Generator Test Systems Page 93 of 110 j 8 1 No. H ltl 497 2 TSH-GA-Process 210B-3 Switch TSH-GA-Process 498 2 2018 Switch 499 TSH-GA-Process 2 202B Switch soo 2 TSH-GA-Process 203B Switch 501 2 TSH-GA-Process 210C-1 Switch S02 2 TSH-GA-Process 210C-2 Switch 503 2 TSH-GA-Process 210C-3 Switch 504 2 TSH-GA-Process 201C Switch 50S 2 TSH-GA-Process 202C Switch 506 TSH-GA-Process 2 203C Switch 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure ,j e:i:1ng] Component Evaluation Floor En ction I r I -Basis for Evaluation ID Type Elev. (ftJ Capatity Result AC/DC Power Jacket Coolant Allen Bradley 837-V3J 2B-GS01 Diesel Diesel 217 Qualification Cap> Dem Support Temperature Switch Engine Generator Test Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J 2B-GS01 Diesel Diesel 217 Qualification Cap> Dem Support Temperature Switch Engine Generator Test Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J 2B-GS01 Diesel Diesel 217 Qualification Cap> Dem Support Temperature Switch Engine Generator Test Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J 2B-GS01 Diesel Diesel 217 Qualification Cap>Dem Support Temperature Sw i tch Engine Generator Test Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J 2C-G501 Diesel Diesel 217 Qualification Cap> Dem Support Temperature Switch Engine Generator Test Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J 2C-GS01 Diesel Diesel 217 Qualification Cap> Dem Support Temperature Switch Engine Generator Test Systems AC/DC Power Jacket Coolant Allen Bradley 837-V3J 2C-G501 Diesel Diesel 217 Qualification Support Temperature Switch Engine Generator Test Cap> Dem Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J 2C-G501 Diesel Diesel 217 Qualification Support Temperature Switch Engine Generator Test Cap> Dem Systems AC/DC Power Lube Oil High Allen Bradley 837-V3J 2C-GS01 D ie sel Diesel 217 Qualification Support Temperature Switch Engine Generator Test Cap> Dem Systems AC/DC Power Lube Oil High Allen Bradley 2C-G501 Diesel Diesel Qualification 837-V3J 217 Cap> Dem Support Temperature Switch Engine Generator Test Systems Page 94of110 No. 507 2 508 2 509 2 510 2 511 2 512 2 513 1 514 1 515 1 15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation
-Component Enclosure I I Floor -Component Evaluation t= =J j System]
_J ; Elev. (ft) Basis for Evaluation Model No. Capacltv Result AC/DC TSH-G A-Process Power Jacket Coolant Allen Bradley 837-V3J 2D-G501 Diesel Diesel 217 Qualification Cap> Dem 210D-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Jacket Coolant Allen Bradley 837-V3J 2D-G501 Diesel Diesel 217 Qualification Cap> Dem 210D-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Jacket Coolant Allen Bradley 837-V3J 2D-G501 Diesel Diesel 217 Qualification Cap> Dem 210D-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Lube Oil High Allen Bradley 837-V3J 2D-G501 Diesel Diesel 217 Qualification Cap> Dem 2010 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA-Process Power Lube Oil High Allen Bradley 837-V3J 2D-G501 Diesel Diesel 217 Qualification Cap> Dem 202D Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-G A-Process Power Lube Oil High Allen Bradley 837-V3J 2D-G501 Diesel Diesel 217 Qualification Cap> Dem 203D Switch Support Temperature Switch Engine Generator Test Systems AC/DC Load D114-33 Low Voltage Power D114-D-G Motor K-600 Center Reactor Qualification (52-20133)
Circuit Support Control Center ABB/ITE Breaker D114-33 I Enclosure 313 Test Cap> Dem Breaker Switch Systems gear AC/DC Load D114-32 Low Voltage Power D114-R-G Motor K-600 Center Reactor Qualification (52-20132)
Circuit Support Control Center ABB/ITE Breaker D114-32 I Enclosure 313 Test Cap> Dem Breaker Systems Circuit Breaker Switch gear AC/DC Load D124-33 Low Voltage Power D124-D-G Motor K-600 Center Reactor Qualification (52-20233)
Circuit Support Control Center ABB/ITE Breaker D124-33 I Enclosure 313 Test Cap> Dem Breaker Systems Switch gear Page 95 of 110 
-I N o.* . Unit *10 Type ..J Low Voltage D124-32 516 1 (52-20232) Circuit Breaker Low Voltage D134-33 517 1 Circuit (52-20333)
Breaker Low Voltage D134-24 518 1 (52-20324)
Circuit Breaker Low Voltage 519 D144-33 Circuit 1 (52-20433)
Breaker Low Voltage D144-24 520 1 (S2-20424)
Circuit Breaker D214-33 Low Voltage 521 2 Circuit (52-20133)
Breaker Low Voltage 0214-32 522 2 {52-20132)
Circuit Breaker D224-33 Low Voltage 523 2 {52-20233)
Circuit Breaker 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure r F.loor Component Evaluation Building j Basis for Evaluation System Function Manufacturer Model No. ID Type Elev. (ft) Capacltv Result Load AC/DC D124-R-G Motor Center Power Control Center ABB/ITE K-600 D124-32 I Reactor 313 Qualification Cap> Dem Support Breaker Enclosure Test Circuit Breaker Sw i tch Systems gear Load AC/DC Center Power D134-D-G Motor K-600 Reactor Qualification Control Center ABB/ITE Breaker D134-33 I Enclosure 253 Test Cap> Dem Support Switch Systems gear AC/DC Load D134-R-E Motor Center Power K-600 Reactor Qualification Control Center ABB/ITE Breaker D134-24 I Enclosure 253 Test Cap> Dem Support Circuit Breaker Switch Systems gear AC/DC Load Center Power D144-D-G Motor ABB/ITE K-600 D144-33 I Reactor 283 Qualification Cap> Dem Support Control Center Breaker Enclosure Test Switch Systems gear AC/DC Load D144-R-E Motor Center Power K-600 Reactor Qualification Support Control Center ABB/ITE Breaker D144-24 I Enclosure 283 Test Cap> Dem Circuit Breaker Switch Systems gear AC/DC Load Power D214-D-G Motor K-600 Center Reactor Qualification ABB/ITE D214-33 I 313 Cap> Dem Support Control Center Breaker Switch Enclosure Test Systems gear AC/DC Load D214-R-G Motor Center Power K-600 Reactor Qualification Support Control Center ABB/ITE Breaker D214-32 I Enclosure 313 Test Cap> Dem Circuit Breaker Switch Systems gear AC/DC Load Power 0224-D-G Motor K-600 Center Reactor Qualification Support Control Center ABB/ITE Breaker D224-33 I Enclosure 313 Test Cap> Dem Switch Systems gear Page 96 of 11 O I No.1 I -Unit [
D224-32 Low Voltage 524 2 Circuit {52-20232)
Breaker Low Voltage 525 2 D234-33 Circuit (52-20333)
Breaker D234-24 Low Voltage 526 2 {52-20324)
Circuit Breaker D244-33 Low Voltage 527 2 (52-20433)
Circuit Breaker D244-24 Low Voltage 528 2 Circuit {52-20424)
Breaker Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Building I [_FUn ction ..
I [i ype] ID AC/DC Load Power D224-R-G Motor K-600 Center Reactor Control Center ABB/ITE D224-32 I Support Breaker Enclosure Systems Circuit Breaker Switch gear AC/DC Load Center Power D234-D-G Motor ABB/ITE K-600 D234-33 I Reactor Support Control Center Breaker Enclosu re Systems Switch gear AC/DC Load Power D234-R-E Motor K-600 Center Reactor Support Control Center ABB/ITE Breaker D234-24 I Enclosu re Systems Circuit Breaker Switch gear AC/DC Load Power D244-D-G Motor K-600 Center Reactor Support Control Center ABB/ITE Breaker D244-33 I Enclosure Systems Switch gear AC/DC Load Power D244-R-E Motor K-600 Center Reactor Contro l Center ABB/ITE D244-24 I Support Breaker Enclosure Systems Circu i t Breaker Switch gear 1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Floor Component Evaluation Elev. {ft) Basis for Evaluation ca o acitV Result Qualification 313 Cap> Dem Test 253 Qualification Cap> Dem Test Qualification 253 Test Cap> Dem Qualification 283 Test Cap> Dem Qualification 283 Cap> Dem Test Page 97 of 110 VAi.VE Ill> (Qn P&ID HV-lFOOl HV-1F002 HV-lFOOS HV-lFOllA lFOlOA HV-1F074A HV-lFOllB lFOlOB HV-1F074B PSV-1F013A 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I -PIMSID. *'I P&ID f .SHEET Notes Evaluated in Re f. [1:8] I I -HV-041-lFOOl M-0041 1 Yes* HV-041-1F002 M-0041 1 Yes* NORMALLY OPEN TO MAIN HV-041-lFOOS M-0041 1 STEAM LINE C. NOT A LEAK PATH No (No Need to be included-Line C is isolated)
DOWN STREAM CHECK VALVE HV-HV-041-lFOllA M-0041 1 lFOlOA will provide Boundary (No No Need to be included) 041-lFOlOA M-0041 1 SIMPLE CHECK VALVE (No Need to No be included)
HV-041-1F074A M-0041 1 DOWN STREAM OF CHECK VALVE (No Need to be included)
No DOWN STREAM CHECK VALVE HV-HV-041-lFOllB M-0041 1 lFOlOB will provide Boundary (No No Need to be included) 041-lFOlOB M-0041 1 SIMPLE CHECK VALVE (No Need to No be included)
HV-041-1F074B M-0041 1 DOWN STREAM OF CHECK VAL VE (No Need to be included)
No PSV-041-1F013A M-0041 2 SRV Yes* Page 98of110 VALVE Ill> on i' P&ID PSV-1F013B PSV-1F013C PSV-1F013D PSV-1F013E PSV-1F013F PSV-1F013G PSV-1F013H PSV-1F013J PSV-1F013K PSV-1F013L PSV-1F013M PSV-1F013S PSV-1F013N HV-F022A HV-F028A HV-F022B 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation
-PIMSID I P&ID SHEET Notes Evaluated in Ref., [18) PSV-041-1F013B M-0041 2 SRV Yes* PSV-041-1F013C M-0041 2 SRV Yes* PSV-041-1F013D M-0041 2 SRV Yes* PSV-041-1F013E M-0041 2 SRV Yes* PSV-041-1F013F M-0041 2 SRV Yes* PSV-041-1F013G M-0041 2 SRV Yes* PSV-041-1F013H M-0041 2 SRV Yes* PSV-041-1F013J M-0041 2 SRV Yes* PSV-041-1F013K M-0041 2 SRV Yes* PSV-041-1F013L M-0041 2 SRV Yes* PSV-041-1F013M M-0041 2 SRV Yes* PSV-041-1F013S M-0041 2 SRV Yes* PSV-041-1F013N M-0041 2 SRV Yes* HV-041-1F022A M-0041 2 Yes* HV-041-1F028A M-0041 2 Yes* HV-041-1F022B M-0041 2 Yes* Page 99of110 


ID on I P&ID --' HV-F028B HV-F022C HV-F028C HV-F022D HV-F028D HV-C-F020 HV-1F016 HV-1F019 HV-lFlOS HV-lFOOl HV-1F004 HV-lFlOO 15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation
15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I            - -*                            I VALVE ID on PIMSID 1
[ PIMS l lD J P&ID I l Notes l Evaluated in Ref. [18] HV-041-1F028B M-0041 2 Yes* HV-041-1F022C M-0041 2 Yes* HV-041-1F028C M-0041 2 Yes* HV-041-1F022D M-0041 2 Yes* HV-041-1F028D M-0041 2 Yes* HV-C-041-1F020 M-0041 2 Yes* HV-041-lFOlG M-0041 2 Normally Closed Drain Line Yes* Normally Closed Drain Line would No -See notes and discussion in HV-041-1F019 M-0041 2 only be a Leak Path if HV-1F016 Section 2.2 of this report. Opens HV-044-lFlDS M-0044 1 Normally Open-Need to check if Yes* there is a signal to close Would only be a Leak Path if HV-No -See notes and discussion in HV-044-lFOOl M-0044 1 lFlOS fails to be closed Section 2.2 of this report. Would only be a Leak Path if HV-No -See notes and discussion in HV-044-1F004 M-0044 1 lFlOS fails to be closed Section 2.2 of this report. HV-044-lFlOO M-0044 1 Normally Open-Need to check if Yes* there is a signal to close Page 100of110 VAl!.VE ID on P&ID ' I HV-1F007 HV-1F008 HV-1F021A HV-1F016A HV-1F041C HV-1F017C HV-1F041A HV-1F017A HV-1F050A HV-1F015A 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMS ID Notes l' Evaluated in Ref. (18] ___J --HV-049-1F007 M-0049 1 Normally Open-Need to check if Yes* there is a signal to close Would only be a Leak Path if HV-No -See notes and discussion in HV-049-lFOOS M-0049 1 1F107 fails to be closed Section 2.2 of this report. Per the Plant this is the HV-051-1F021A M-0051 1 Containment Spray Valves and No -See Note does not communicate with the Reactor Per the Plant this is the HV-051-1F016A M-0051 1 Containment Spray Valves and No -See Note does not communicate with the Reactor HV-051-1F041C M-0051 1 CHECK VALVE Yes* HV-051-1F017C M-0051 1 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-1F041A M-0051 1 CHECK VALVE Yes* HV-051-1F017A M-0051 1 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-1F050A M-0051 1 CHECK VALVE Yes* HV-051-1F015A M-0051 1 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. Page 101 of 110 VALVE ID on P&ID HV-1F008 HV-1F021B HV-1F016B HV-1F041D HV-1F017D HV-1F041B
P&ID     SHEET                Notes                     Evaluated in Ref. [18]
P&ID JI                I
-                   ~
No - See notes and discussion in HV-2F017D    HV-051-2F017D    M-0051      7      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
HV-2F041B    HV-051-2F041B    M-0051      7              CHECK VALVE                              Yes*
No - See notes and discussion in HV-2F017B    HV-051-2F017B    M-0051      7      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
HV-2F050B    HV-051-2F050B    M-0051      7              CHECK VALVE                              Yes*
No - See notes and discussion in HV-2F015B    HV-051-2F015B    M-0051      7      DOWN STREAM OF CHECK VALVE Section 2.2 of this report.
HV-2F009      HV-051-2F009    M-0051     7                                                        Yes*
HV-2F006B    HV-052-2F006B    M-0052      3              CHECK VALVE                             Yes*
DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-208        HV-052-208      M-0052      3      Only needed if HV-2F006B fails to Section 2.2 of this report.
be closed HV-2F006A    HV-052-2F006A    M-0052      3              CHECK VALVE                             Yes*
DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-2F005      HV-052-2F005      M-0052      3      Only needed if HV-2F006A fails to Section 2.2 of this report.
be closed Page 109of110


HV-1F017B HV-1F050B HV-1F015B HV-1F009 HV-1F006B 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMSID P&ID I SHEET Notes I Evaluated in 1 Ref. [18) ------HV-051-lFOOB M-0051 1 Yes* Per the Plant this is the HV-M51-1F021B M-0051 3 Containment Spray Valves and No -See Note does not communicate with the Reactor Per the Plant this is the HV-051-1F016B M-0051 3 Containment Spray Valves and No -See Note does not communicate with the Reactor HV-051-1F041D M-0051 3 CHECK VALVE Yes* HV-051-1F017D M-0051 3 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-1F041B M-0051 3 CHECK VALVE Yes HV-051-1F017B M-0051 3 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-1F050B M-0051 3 CHECK VALVE Yes* HV-051-1F015B M-0051 3 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-1F009 M-0051 3 Yes* HV-052-lFOOGB M-0052 1 CHECK VALVE Yes* Page 102 of 110 VA l.\VE ID on ! [ P&ID HV-108 HV-1F006A HV-1F005 HV-1F002 HV-1F003 HV-2F001 HV-2F002 HV-2F005 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation 1 P&ID Note; . -,. Evaluated in 1 Ref.
15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE ID on PIMSID            P&ID     I, SHEET                   Notes                         Evaluated in Ref. [18)
DOWN STREAM OF CHECK VALVE No -See notes and discussion in HV-052-108 M-0052 1 Only needed if HV-1F006B fails to Section 2.2 of this report. be closed HV-052-lFOOGA M-0052 1 CHECK VALVE Yes* DOWN STREAM OF CHECK VALVE No -See notes and discussion in HV-052-1F005 M-0052 1 Only needed if HV-1F006A fails to be closed Section 2.2 of this report. HV-055-1F002 M-0055 1 Normally Open-Need to check if Yes* there is a signal to close HV-055-1F003 M-0055 1 Would only be a potential Leak No -See notes and discussion in Path if HV-1F002 fails to be closed Section 2.2 of this report. HV-041-2F001 M-0041 4 Yes* HV-041-2F002 M-0041 4 Yes* NORMALLY OPEN TO MAIN HV-041-2F005 M-0041 4 STEAM LINE C. NOT A LEAK PATH (No Need to be included-Line C is No isolated)
P&ID Normally Open- Need to check if HV-2F002       HV-055-2F002         M-0055         2                                                             Yes*
Page 103 of 11 O VALVE 10., on , P&ID I I HV-2F011A 2F010A HV-2F074A HV-2F011B 2F010B HV-2F074B PSV-2F013A PSV-2F013B PSV-2F013C 1SC4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMS ID P&ID SHEET : Notes I Evaluated in Ref. [18) DOWN STREAM CHECK VALVE HV-HV-041-2F011A M-0041 4 2F010A will provide Boundary (No No Need to be included) 041-2F010A M-0041 4 SIMPLE CHECK VALVE {No Need to No be included)
there is a signal to close Would only be a potential Leak           No - See notes and discussion in HV-2F003        HV-055-2F003         M-0055         2 Path if HV-2F002 fails to be closed         Section 2.2 of this report.
HV-041-2F074A M-0041 4 DOWN STREAM OF CHECK VALVE No (No Need to be included)
* Note: the evaluation of this valve is discussed in Section 2.2 of this report as well as in report 15C4344-RPT-001 (Ref. 18).
DOWN STREAM CHECK VALVE HV-HV-041-2F011B M-0041 4 2F010B will provide Boundary (No No Need to be included) 041-2F010B M-0041 4 SIMPLE CHECK VALVE (No Need to No be included)
Page 11 O of 11 O}}
HV-041-2F074B M-0041 4 DOWN STREAM OF CHECK VALVE (No Need to be included)
No PSV-041-2F013A M-0041 5 SRV Yes* PSV-041-2F013 B M-0041 5 SRV Yes* PSV-041-2F013C M-0041 5 SRV Yes* Page 104of110 VAL\lE ID mi! *
* P&ID I PSV-2F013D PSV-2F013E PSV-2F013F PSV-2F013G PSV-2F013H PSV-2F013J PSV-2F013K PSV-2F013L PSV-2F013M PSV-2F0135 PSV-2F013N HV-F022A 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMS[ P&ID J [ Notes l Evaluated in Ref. r[l8] PSV-041-2F013D M-0041 5 SRV Yes* PSV-041-2F013E M-0041 5 SRV Yes* PSV-041-2F013F M-0041 5 SRV Yes* PSV-041-2F013G M-0041 5 SRV Yes* PSV-041-2F013H M-00 41 5 SRV Yes* PSV-041-2F013J M-0041 5 SRV Yes* PSV-041-2F013K M-0041 5 SRV Yes* PSV-041-2F013L M-0041 5 SRV Yes* PSV-041-M-0041 5 SRV Yes* 2F013M PSV-041-2F0135 M-0041 5 SRV Yes* PSV-041-2F013N M-0041 5 SRV Yes* HV-041-2F022A M-0041 5 Yes* Page 105of110 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation Iii> on r ] I SHEET I [
1 -P&ID Evaluated in Ref. 1[l8] P&ID HV-F028A HV-041-2F028A M-0041 5 Yes* HV-F022B HV-041-2F022B M-0041 5 Yes* HV-F028B HV-041-2F028B M-0041 5 Yes* HV-F022C HV-041-2F022C M-0041 5 Yes* HV-F028C HV-041-2F028C M-0041 5 Yes* HV-F022D HV-041-2F022D M-0041 5 Yes* HV-F028D HV-041-2F028D M-0041 5 Yes* HV-C-F020 HV-C-041-2F020 M-0041 5 Yes* HV-2F016 HV-041-2F016 M-0041 5 Normally Closed Drain Line Yes* Normally Closed Drain Line would No -See notes and discussion in HV-2F019 HV-041-2F019 M-0041 5 only be a Leak Path if HV-2F016 Section 2.2 of this report. Opens HV-2F105 HV-044-2F105 M-0044 3 Normally Open-Need to check if Yes* there is a signal to close Page 106 of 110 VALVJ ID on I 1 P&ID HV-2F001 HV-2F004 HV-2F100 HV-2F007 HV-2F008 HV-2F021A HV-2F016A HV-2F041C 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 8-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMSID I P&ID SHEET Notes Evaluated in Ref. 1[1.8] I HV-044-2F001 M-0044 3 Would only be a Leak Path if HV-No -See notes and discussion in 2F105 fails to be closed Section 2.2 of this report. HV-044-2F004 Would only be a Leak Path if HV-No -See notes and discussion in M-0044 3 2F105 fails to be closed Section 2.2 of this report. HV-044-2F100 M-0044 3 Normally Open-Need to check if Yes* there is a signal to close HV-049-2F007 M-0049 2 Normally Open-Need to check if Yes* there is a signal to close HV-049-2F008 M-0049 2 Would only be a Leak Path if HV-No -See notes and discussion in 2F107 fails to be closed Section 2.2 of this report. Per the Plant this is the HV-051-2F021A M-0051 5 Containment Spray Valves and No -See Note does not communicate with the Reactor Per the Plant this is the HV-051-2F016A M-0051 5 Containment Spray Valves and No -See Note does not communicate with the Reactor HV-051-2F041C M-0051 5 CHECK VALVE Yes* Page 107of110 VALVE ID on 1 P&ID -HV-2F017C HV-2F041A HV-2F017A HV-2F050A HV-2F015A HV-2F008 HV-2F021B HV-2F016B HV-2F041D 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMSW) P&ID SHEET Notes Evaluated in Ref. [18] I HV-051-2F017C M-0051 5 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-2F041A M-0051 5 CHECK VALVE Yes* HV-051-2F017A M-0051 5 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-2F050A M-0051 5 CHECK VALVE Yes* HV-051-2F015A M-0051 5 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-2F008 M-0051 5 Yes* Per the Plant this is the HV-M51-2F021B M-0051 7 Containment Spray Valves and No -See Note does not communicate with the Reactor Per the Plant this is the HV-051-2F016B M-0051 7 Containment Spray Valves and No -See Note does not communicate with the Reactor HV-051-2F041D M-0051 7 CHECK VALVE Yes* Page 108 of 110 VALVE ID on P&ID JI -HV-2F017D HV-2F041B HV-2F017B HV-2F050B HV-2F015B HV-2F009 HV-2F006B HV-208 HV-2F006A HV-2F005 15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I --* I 1 PIMSID P&ID SHEET Notes Evaluated in Ref. [18] I -HV-051-2F017D M-0051 7 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-2F041B M-0051 7 CHECK VALVE Yes* HV-051-2F017B M-0051 7 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-2F050B M-0051 7 CHECK VALVE Yes* HV-051-2F015B M-0051 7 DOWN STREAM OF CHECK VALVE No -See notes and discussion in Section 2.2 of this report. HV-051-2F009 M-0051 7 Yes* HV-052-2F006B M-0052 3 CHECK VALVE Yes* DOWN STREAM OF CHECK VALVE No -See notes and discussion in HV-052-208 M-0052 3 Only needed if HV-2F006B fails to Section 2.2 of this report. be closed HV-052-2F006A M-0052 3 CHECK VALVE Yes* DOWN STREAM OF CHECK VALVE No -See notes and discussion in HV-052-2F005 M-0052 3 Only needed if HV-2F006A fails to Section 2.2 of this report. be closed Page 109of110 VALVE ID on P&ID HV-2F002 HV-2F003 15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMSID P&ID I , SHEET Notes Evaluated in Ref. [18) ' --HV-055-2F002 M-0055 2 Normally Open-Need to check if Yes* there is a signal to close Would only be a potential Leak No -See notes and discussion in HV-055-2F003 M-0055 2 Path if HV-2F002 fails to be closed Section 2.2 of this report.
* Note: the evaluation of this valve is discussed in Section 2.2 of this report as well as in report 15C4344-RPT-001 (Ref. 18). Page 11 O of 11 O}}

Latest revision as of 22:53, 4 February 2020

High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from The..
ML16333A084
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 11/28/2016
From: Jim Barstow
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RS-16-177
Download: ML16333A084 (114)


Text

Exelon Generation ~,

RS-16-177 10 CFR 50.54(f)

November 28, 2016 U.S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRG Docket Nos. 50-352 and 50-353

Subject:

High Frequency Supplement to Seismic Hazard Screening Report, Response to NRG Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident

References:

1. NRG Letter, Request for Information Pursuant to Title 1O of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 12, 2012(ML12053A340}
2. NRG Letter, Electric Power Research Institute Report 3002000704, "Seismic Evaluation Guidance: Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," As An Acceptable Alternative to the March 12, 2012, Information Request for Seismic Reevaluations, dated May 7, 2013 (ML13106A331)
3. NEI Letter, Final Draft of Industry Seismic Evaluation Guidance, Screening, Prioritization and Implementation Details (SPID) for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic (EPRI 1025287), dated November 27, 2012 (ML12333A168 and ML12333A170)
4. NRG Letter, Endorsement of Electric Power Research Institute Final Draft Report 1025287, "Seismic Evaluation Guidance, Screening, Prioritization and Implementation Details (SPID) for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," dated February 15, 2013(ML12319A074)
5. Exelon Generation Company, LLC letter to NRG, Limerick Generating Station, Units 1 and 2 - Seismic Hazard and Screening Report (CEUS Sites}, Response to NRG Request for Information Pursuant to 10CFR50.54(f) Regarding Recommendation 2.1 of Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated March 31, 2014 (RS-14-069) (ML14090A236}

U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 28, 2016 Page 2

6. NRC Letter, Screening and Prioritization Results Regarding Information Pursuant to Title 1O of the Code of Federal Regulations 50.54(f) Regarding Seismic Hazard Re-evaluations for Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated May 9, 2014 (ML14111A147)
7. NRC Memorandum, Support Document for Screening and Prioritization Results Regarding Seismic Hazard Re-Evaluation for Operating Reactors in the Central and Eastern United States, dated May 21, 2014 (ML14136A126)
8. NEI Letter, Request for NRC Endorsement of High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396),

dated July 30, 2015 (ML15223A100/ML15223A102)

9. NRC Letter to NEI: Endorsement of Electric Power Research Institute Final Draft Report 3002004396: "High Frequency Program: Application Guidance for Functional Confirmation and Fragility," dated September 17, 2015 (ML15218A569) 1O. NRC Letter, Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 1O of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated October 27, 2015 (ML15194A015)

On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued a Request for Information per 10 CFR 50.54(f) (Reference 1) to all power reactor licensees. The required response section of Enclosure 1 of Reference 1 indicated that licensees should provide a Seismic Hazard Evaluation and Screening Report within 1.5 years from the date of the letter for Central and Eastern United States (CEUS) nuclear power plants. By NRC letter dated May 7, 2013 (Reference 2), the date to submit the report was extended to March 31, 2014.

By letter dated May 9, 2014 (Reference 6), the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation report for Limerick Generating Station, Units 1 and 2 submitted on March 31, 2014 (Reference 5). In accordance with the Screening, Prioritization, and Implementation Details report (SPID) (References 3 and 4), and Augmented Approach Guidance (Reference 2), the reevaluated seismic hazard is used to determine if additional seismic risk evaluations are warranted for a plant. Specifically, the reevaluated horizontal Ground Motion Response Spectrum (GMRS) at the control point elevation is compared to the existing Safe Shutdown Earthquake (SSE) or Individual Plant Examination for External Events (IPEEE) High Confidence of Low Probability of Failure (HCLPF) Spectrum (IHS) to determine if a plant is required to perform a high frequency confirmation evaluation. As noted in the May 9, 2014 letter from the NRC (Reference 6) on page 3 of Enclosure 2, Limerick Generating Station, Units 1 and 2 is to conduct a limited scope High Frequency Evaluation (Confirmation).

Within the May 9, 2014 letter (Reference 6), the NRC acknowledged that these limited scope evaluations will require additional development of the assessment process. By Reference 8, the Nuclear Energy Institute (NEI) submitted an Electric Power Research Institute (EPRI) report entitled, High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396) for NRC review and endorsement. NRC endorsement

U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 28, 2016 Page 3 was provided by Reference 9. Reference 10 provided the NRC final seismic hazard evaluation screening determination results and the associated schedules for submittal of the remaining seismic hazard evaluation activities.

The High Frequency Evaluation Confirmation Report for Limerick Generating Station, Units 1 and 2, provided in the enclosure to this letter, shows that all high frequency susceptible equipment evaluated within the scoping requirements and using evaluation criteria of Reference 8 for seismic demands and capacities, are acceptable. Therefore, no additional modifications or evaluations are necessary.

This transmittal completes the scope of work described in Section 4.2 of Reference 5 for Limerick Generating Station, Units 1 and 2.

This letter closes the associated regulatory commitment contained in Enclosure 2 of Reference 5 for Limerick Generating Station, Units 1 and 2.

This letter contains no new regulatory commitments.

If you have any questions regarding this report, please contact Ronald Gaston at 630-657-3359.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 281h day of November 2016.

Respectfully submitted,

~kf:-

James Barstow Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC

Enclosure:

Limerick Generating Station, Units 1 and 2 - Seismic High Frequency Evaluation Confirmation Report cc: NRC Regional Administrator - Region I NRC Project Manager, NRA - Limerick Station NRC Senior Resident Inspector - Limerick Station Mr. Brett A. Titus, NRR/JLD/JCBB, NRC Mr. Stephen M. Wyman, NRR/JLD/JHMB, NRC Mr. Frankie G. Vega, NRR/JLD/JHMB, NRC Director, Bureau of Radiation Protection - Pennsylvania Department of Environmental Resources R. R. Janati, Chief, Division of Nuclear Safety, Pennsylvania Department of Environmental Protection, Bureau of Radiation Protection

Enclosure Limerick Generating Station, Units 1 and 2 Seismic High Frequency Evaluation Confirmation Report (11 O pages)

HIGH FREQUENCY CONFIRMATION REPORT IN RESPONSE TO NEAR TERM TASK FORCE (NTIF) 2.1 RECOMMENDATION for the LIMERICK GENERATING STATION, UNITS 1 AND 2 3146 Sanatoga Rd, Pottstown, PA 19464 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353 Correspondence No.: RS-16-177 Exelon Exelon Generation Company, LLC (Exelon)

PO Box 805398 Chicago, IL 60680-5398 Prepared by:

Stevenson & Associates 1661 Feehanvllle Drive, Suite 150 Mount Prospect, IL 60056 Report Number: 15C4345-RPT-002, Rev. O Printed Name Signature ~

Preparer: F. Ganatra 10/27/2016 Reviewer: M. Delaney 10/27/2016 Approver: M. Delaney 10/27/2016 Lead Responsible Engineer. Lll!M ~=='=' 11/t-,i!D/~

BranchManaser: ~\U.D~ \\~~l \Cc.

Senior Manager ~ --1~~_,q._...;:::o._ __

Design En1lneerln1: -S-,...., &r1 11tt 1 "I er/ 1b Corporate Acceptance: \iSSru, S. C lAr \c. 11/.,/20ue

Document ID: 15C4345-RPT-002

Title:

High Frequency Confirmation Report for Limerick Generating Station, Unit 1 and 2 in Response to Near Term Task Force (NTTF) 2.1 Recommendation Document Type:

Criteria D Interface D Report ~ Specification D Other D Drawing D Project Name:

Limerick, Unit 1 and 2 High Frequency Confirmation Job No.: 15C4345 Client:

~

Exelon ~

This document has been prepared under the guidance of the S&A Quality Assurance Program Manual, Revision 18 and project requirements:

For Owner's Acceptance Review (Rev. 0)

Date: 10/27/2016 Originated by: F. Ganatra fU- 4~

Date: 10/27/2016 Checked by: M. Delaney ~/t(~

Date: 10/27/2016 Approved by: M. Delaney ~ft(~

Revision Record:

Revision Originated by/ Checked by/ Approved by/ Description of Revision No. Date Date Date DOCUMENT PROJECT NO.

APPROVAL SHEET 15C4345 Figure 2.8 Stevenson & Associates

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Executive Summary The purpose of this report is to provide information as requested by the Nuclear Regulatory Commission (NRC) in its March 12, 2012 letter issued to all power reactor licensees and holders of construction permits in active or deferred status [l]. In particular, this report provides information requested to address the High Frequency Confirmation requirements of Item (4), Enclosure 1, Recommendation 2.1: Seismic, of the March 12, 2012 letter [1].

Following the accident at the Fukushima Dai-ichi nuclear power plant resulting from the March 11, 2011, Great Tohoku Earthquake and subsequent tsunami, the Nuclear Regulatory Commission (NRC}

established a Near Term Task Force (NTIF) to conduct a systematic review of NRC processes and regulations and to determine if the agency should make additional improvements to its regulatory system . The NTIF developed a set of recommendations [15] intended to clarify and strengthen the regulatory framework for protection against natural phenomena. Subsequently, the NRC issued a 50.54(f} letter on March 12, 2012 [1], requesting information to assure that these recommendations are addressed by all U.S. nuclear power plants. The 50.54(f} letter requests that licensees and holders of construction permits under 10 CFR Part 50 reevaluate the seismic hazards at their sites against present-day NRC requirements and guidance. Included in the 50.54(f} letter was a request that licensees' perform a "confirmation, if necessary, that SSCs, which may be affected by high-frequency ground motion, will maintain their functions important to safety."

EPRI 1025287, "Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details (SPID} for the resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic" [6]

provided screening, prioritization, and implementation details to the U.S. nuclear utility industry for responding to the NRC 50.54(f} letter. This report was developed with NRC participation and was subsequently endorsed by the NRC. The SPID included guidance for determining which plants should perform a High Frequency Confirmation and identified the types of components that should be evaluated in the evaluation.

Subsequent guidance for performing a High Frequency Confirmation was provided in EPRI 3002004396, "High Frequency Program, Application Guidance for Functional Confirmation and Fragility Evaluation," [8] and was endorsed by the NRC in a letter dated September 17, 2015 [3]. Final screening identifying plants needing to perform a High Frequency Confirmation was provided by NRC in a letter dated October 27, 2015 [2].

This report describes the High Frequency Confirmation evaluation undertaken for Limerick Generating Station, Unit 1 and 2 (LIM). The objective of this report is to provide summary information describing the High Frequency Confirmation evaluations and results. The level of detail provided in the report is intended to enable NRC to understand the inputs used, the evaluations performed, and the decisions made as a result of the evaluations.

EPRI 3002004396 [8] is used for the LIM engineering evaluations described in this report. In accordance with Reference [8], the following topics are addressed in the subsequent sections of this report:

  • Process of selecting components and a list of specific components for high-frequency confirmation
  • Estimation of a vertical ground motion response spectrum (GMRS}

Page 3of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177

  • Estimation of in-cabinet seismic demand for subject components
  • Estimation of in-cabinet seismic capacity for subject components
  • Summary of subject components' high-frequency evaluations Page 4 of 110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 1 Introduction 1.1 PURPOSE The purpose of this report is to provide information as requested by the NRC in its March 12, 2012 S0.54(f) letter issued to all power reactor licensees and holders of construction permits in active or deferred status [1]. In particular, this report provides requested information to address the High Frequency Confirmation requirements of Item (4), Enclosure 1, Recommendation 2.1:

Seismic, ofthe March 12, 2012 letter [1].

1.2 BACKGROUND

Following the accident at the Fukushima Dai-ichi nuclear power plant resulting from the March 11, 2011, Great Tohoku Earthquake and subsequent tsunami, the Nuclear Regulatory Commission (NRC) established a Near Term Task Force (NTIF) to conduct a systematic review of NRC processes and regulations and to determine if the agency should make additional improvements to its regulatory system. The NTIF developed a set of recommendations intended to clarify and strengthen the regulatory framework for protection against natural phenomena.

Subsequently, the NRC issued a 50.54(f) letter on March 12, 2012 [1], requesting information to assure that these recommendations are addressed by all U.S. nuclear power plants. The 50.54(f) letter requests that licensees and holders of construction permits under 10 CFR Part 50 reevaluate the seismic hazards at their sites against present-day NRC requirements and guidance.

Included in the 50.54(f) letter was a request that licensees' perform a "confirmation, if necessary, that SSCs, which may be affected by high-frequency ground motion, will maintain their functions important to safety."

EPRI 1025287, "Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details (SPID) for the resolution of Fukushima Near-Term Task Force Recommendation 2.1:

Seismic" [6] provided screening, prioritization, and implementation details to the U.S. nuclear utility industry for responding to the NRC 50.54(f) letter. This report was developed with NRC participation and is endorsed by the NRC. The SPID included guidance for determining which plants should perform a High Frequency Confirmation and identified the types of components that should be evaluated in the evaluation .

Subsequent guidance for performing a High Frequency Confirmation was provided in EPRI 3002004396, "High Frequency Program, Application Guidance for Functional Confirmation and Fragility Evaluation," [8] and was endorsed by the NRC in a letter dated September 17, 2015 [3].

Final screening identifying plants needing to perform a High Frequency Confirmation was provided by NRC in a letter dated October 27, 2015 [2].

On March 31, 2014, LIM submitted a reevaluated seismic hazard to the NRC as a part of the Seismic Hazard and Screening Report [4]. By letter dated October 27, 2015 [2], the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation.

This report describes the High Frequency Confirmation evaluation undertaken for LIM using the methodologies in EPRI 3002004396, "High Frequency Program, Application Guidance for Page 5of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Functional Confirmation and Fragility Evaluation," as endorsed by the NRC in a letter dated September 17, 2015 (3] .

The objective of this report is to provide summary information describing the High Frequency Confirmation evaluations and results. The level of detail provided in the report is intended to enable NRC to understand the inputs used, the evaluations performed, and the conclusions made as a result of the evaluations.

1.3 APPROACH EPRI 3002004396 [8] is used for the LIM engineering evaluations described in this report. Section 4.1 of Reference [8] provided general steps to follow for the high frequency confirmation component evaluation. Accordingly, the following topics are addressed in the subsequent sections of this report:

  • Selection of components and a list of specific components for high-frequency confirmation
  • Estimation of seismic demand for subject components
  • Estimation of seismic capacity for subject components
  • Summary of subject components' high-frequency evaluations
  • Summary of Results 1.4 PLANT SCREENING LIM submitted reevaluated seismic hazard information including GMRS and seismic hazard information to the NRC on March 31, 2014 (4]. In a letter dated November 6, 2015, the NRC staff concluded that the submitted GMRS adequately characterizes the reevaluated seismic hazard forthe LIM site for 2.1 Seismic (14].

The NRC final screening determination letter concluded [2] that the LIM GMRS to SSE comparison resulted in a need to perform a High Frequency Confirmation in accordance with the screening criteria in the SPID [6].

1.5 REPORT DOCUMENTATION Section 2 describes the selection of devices. The identified devices are evaluated in Reference (17] for the seismic demand specified in Section 3 using the evaluation criteria discussed in Section 4. The overall conclusion is discussed in Section 5.

Table B-1 lists the devices identified in Section 2 and provides the results of the evaluations performed in accordance with Section 3 and Section 4.

Page 6 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 2 Selection of Components for High-Frequency Screening The fundamental objective of the high frequency confirmation review is to determine whether the occurrence of a seismic event could cause credited equipment to fail to perform as necessary. An optimized evaluation process is applied that focuses on achieving a safe and stable plant state following a seismic event. As described in Reference [8], this state is achieved by confirming that key plant safety functions critical to immediate plant safety are preserved (reactor trip, reactor vessel inventory and pressure control, and core cooling) and that the plant operators have the necessary power available to achieve and maintain this state immediately following the seismic event (AC/DC power support systems) .

Within the applicable functions, the components that would need a high frequency confirmation are contact control devices subject to intermittent states in seal-in or lockout circuits. Accordingly, the objective of the review as stated in Section 4.2.1 of Reference (8] is to determine if seismic induced high frequency relay chatter would prevent the completion of the following key functions.

2.1 REACTOR TRIP/SCRAM The reactor trip/SCRAM function is identified as a key function in Reference [8] to be considered in the High Frequency Confirmation. The same report also states that "the design requirements preclude the application of seal-in or lockout circuits that prevent reactor trip/SCRAM functions" and that "No high-frequency review of the reactor trip/SCRAM systems is necessary."

2.2 REACTOR VESSEL INVENTORY CONTROL The reactor coolant system/reactor vessel inventory control systems were reviewed for contact control devices in seal-in and lockout (SILO) circuits that would create a Loss of Coolant Accident (LOCA). The focus of the review was contact control devices that could lead to a significant leak path. Check valves in series with active valves would prevent significant leaks due to misoperation of the active valve; therefore, SILO circuit reviews were not required for those active valves.

The process/criteria for assessing potential reactor coolant leak path valves is to review all P&ID's attached to the Reactor Coolant System (RCS) and include all active isolation valves and any active second valve upstream or downstream that is assumed to be required to be closed during normal operation or close upon an initiating event (Loss of Coolant Accident "LOCA" or Seismic).

A table with the valves and associated P&ID is included in Table B-2 of this report.

Manual valves that are normally closed are assumed to remain closed and a second simple check valve is assumed to function and not be a Multiple Spurious Failure.

Page 7 of 110

15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 On BWR's the instrument lines that are 1" or less, in general, are assumed to have restricting orifices that are designed to mitigate any leakage due to make up.

Table B-2 contains a list of valves analyzed and based on the analysis detailed below, there are no moving contact control devices which could create a LOCA due to chatter-induced sustained valve misalignment, and thus no devices were selected for this category. For valves in Table B-2 that were identified as not requiring evaluation, the justification is provided in the Notes section of the table and is in accordance with guidance criteria.

Nuclear Steam Supply Shutoff Valves Reactor Head Vent Valves HV-041-lFOOl, HV-041-1F002, HV-041-2F001, HV-041-2F002 These two Unit 1 valves [HV-041-lFOOl, HV-041-1F002] are normally closed and in series with one another [23]. Note 39 on the P&ID stipulates HV-041-1F002 is "disabled by locking open the circuit breaker and using administrative controls to assure that the valve is maintained in a closed positon when not in use" [24]. Because HV-041-1F002 is closed, depowered, and blocking flow through HV-041-lFOOl, contact chatter in the control circuits of either valve is irrelevant. Note 50 on the Unit 2 P&ID makes the same statement [25, 26], thus this reasoning applies to the Unit 2 valves HV-041-2F001, HV-041-2F002 as well.

Auto Depressurization Valves PSV-041-1F013E/H/K/M/S, PSV-041-2F013E/H/K/M/S Electrical control for the solenoid-operated pilot valves is via relays B21C-K6A/C/E/G and B21C-K9A/C/E/G [27, 28, 29, 30]. These relays are controlled by the High Drywell Pressure I Reactor Pressure Vessel (RPV) Low Level Logic and the Residual Heat Removal (RHR) Pump Pressure relays B21C-K10A/C/E/G [31, 32]. The RHR Pump Pressure relays do not seal-in [33, 34] and, based on initial conditions at the time of the event, would block any inadvertent seal-in of the High Drywell Pressure I RPV Low Level Logic. Thus there is no SILO relays in this logic which could cause the Auto Depressurization Valves to remain open following a seismic event.

Safety Relief Valves PSV-041-1 F013A/B/C/D/F/G/l/L/N, PSV-041-2F013A/B/C/D/F/G/l/L/N Electrical control for the solenoid-operated pilot valves is via a rugged hand control switch. There are no chatter sensitive contact devices involved in the control of these valves [35, 36, 37, 38].

Main Steam Isolation Valves HV-041-1F022A/B/C/D, HV-041-1F028A/B/C/O, HV-041-2F022A/B/C/D, HV-041-2F028A/B/C/D Electrical control for the solenoid-operated pilot valves is via relays B21H-Kl8A/B/C/D. These relays are slaves to B21H-Kl4A/B/C/D isolation logic relays [39, 40, 41, 42]. These relays are energized for at-power operation and de-energized to close the valves [43, 44, 45, 46]. In the energized state B21H-K14A/B/C/D are sealed in and any chatter in the control logic would break the seal-in and close the valves. This action is a desired response to the seismic event and for this reason chatter is acceptable and no contact devices in this circuit meet the selection criteria.

Page 8of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Main Steam Line Equalizer Valves HV-C-041-1F020, HV-C-041-2F020 These normally-open motor-operated valves are controlled by hand switches only [47, 48, 49].

Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch. Thus these valves are not affected by SILO.

Main Steam Line Drain Valves HV-041-1F016, HV-041-1F019, HV-041-2F016, HV-041-2F019 The opening of normally-closed motor-operated valves HV-041-1F016/ HV-041-2F016 is commanded by a rugged hand switch with no seal-in contacts [SO, 51]. This valve opening control is insensitive to contact chatter and thus the valve will remain closed after the seismic event. As stated in Table B-2, HV-041-1F019/HV-041-2F019 do not need to be analyzed provided HV-041-1F016/HV-041-2F016 remain closed.

Reactor Water Clean-Up Valves Reactor Water Clean-Up Flow Control Valves HV-044-lFlOS, HV-044-2F105; Bottom Head Drain Flow Control Valves HV-044-lFlOO, HV-044-2F100 These normally-open motor-operated valves are controlled by hand switches only [52, 53]. Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch. Thus these valves are not affected by SILO.

Reactor Water Clean-Up Isolation Valves HV-044-lFOOl, HV-044-1F004, HV-044-2F001, HV-044-2F004; Bottom Head Drain Flow Control Valves These are normally-open motor-operated valves which close upon an isolation signal. Open limit switches in the opening circuit prevent seal-in of the opening contactor auxiliary contact and no contacts prevent valve closure via the control switch or isolation relay B21H-K24A/B [54, 55, 56, 57]. These relays are energized for at-power operation and de-energized to close the valves [58, 59, 60, 61]. In the energized state B21H-K24A/B are sealed in and any chatter in the control logic would break the seal-in and close the valves. This action is a desired response to the seismic event and for this reason chatter is acceptable and no contact devices in this circuit meet the selection criteria.

Reactor Core Isolation Cooling Valves Reactor Core Isolation Cooling Steam Supply Line Isolation Valves HV-049-lFOOl, HV-049-lFOOB, HV-049-2F007, HV-049-2FOOB These normally-open motor-operated valves are required to remain open to supply steam to the RCIC turbine. There is no seal-in in the opening circuit, and closure, if needed, is not blocked by SILO [62, 63, 64, 65]. Inadvertent closure of these valves is covered in the RCIC chatter analysis in Section 5.3.7 of Ref. [18].

Residual Heat Removal Valves Testable Check Valves HV-051-1F041A/B/C/D, HV-051-lFOSOA/B, HV-051-2F041A/8/C/D, HV-051-2F050A/B These solenoid-operated valves are controlled by a rugged, normally open push button [66, 67, 68, 69, 70, 71, 72, 73, 74, 75]. There are no SILO devices that would prevent the normal operation of these check valves.

Page 9 of 110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 RHR Injection Valves HV-051-1F017A/B/C/D, HV-051-2F017A/B/C/D; RHR Shutdown Cooling Injection Valves HV-051-1F015A/B, HV-051-2F015A/B Since the testable check valves are not chatter sensitive and can be credited to remain closed, these downstream motor operated valves do not need to be analyzed per the notes in Table B-2.

RHR Shutdown Cooling Isolation Valves HV-051-1F008, HV-051-2F008; RHR Shutdown Cooling Suction Valves HV-051-1F009, HV-051-2F009 These normally-closed motor-operated valves are opened via a normally-open control switch and relay permissive. The valves can be closed manually via the control switch and automatically via an isolation signal. Sympathetic chatter on B21H-K29A/B and 42/0 auxiliary contact could cause valve to open [76, 77, 78, 79], however the low reactor pressure permissive in control logic would prevent seal-in of B21H-K29A/B [58, 59, 60, 61]. After the period of strong shaking the normally-closed contact of B21H-K29A/B (isolation signal) would command these valves to reclose.

Because there is no seal-in and the valves reclose without operator intervention, chatter is acceptable and no contact devices in this circuit meet the selection criteria.

Core Spray Valves Testable Check Valves HV-052-1F006A/B, HV-052-2F006A/B These solenoid-operated valves are controlled by a rugged, normally open push button [80, 81, 82, 83]. There are no SILO devices that would prevent the normal operation of these check valves.

Core Spray Outboard Check Valves HV-052-108, HV-052-208; Core Spray Inboard Motor Operated Valve HV-052-1F005, HV-052-2F005 Since the testable check valves are not chatter sensitive and can be credited to remain closed, these downstream motor operated valves do not need to be analyzed per the notes in Table B-2.

High Pressure Core Injection Valves High Pressure Core Injection Steam Supply Line Isolation Valves HV-055-1F002, HV-055-1F003, HV-055-2F002, HV-055-2F003 These normally-open motor-operated valves supply steam to the HPCI turbine. The opening circuit is controlled by a rugged hand switch and permissive from E41A-K50B/D [84, 85, 86, 87] .

There is no seal-in in the opening circuit. The closing circuit is controlled manually by a rugged hand switch or automatically via the isolation relay E41A-K50B/D [88, 89]. Any chatter in the isolation logic would seal-in E41A-K50B/D and close the valves. Since RCIC, not HPCI, is credited for core cooling this seal-in causing valve closure is not a selection criterion . There is no SILO which would prevent closure of these valves and thus no contact devices in this circuit meet the selection criteria.

Page10of110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 2.3 REACTOR VESSEL PRESSURE CONTROL The reactor vessel pressure control function is identified as a key function in Reference [8) to be considered in the High Frequency Confirmation. The same report also states that "required post event pressure control is typically provided by passive devices" and that "no specific high frequency component chatter review is required for this function."

2.4 CORE COOLING The core cooling systems were reviewed for contact control devices in seal-in and lockout circuits that would prevent at least a single train of non-AC power driven decay heat removal from functioning. Limerick credits their steam turbine-driven Reactor Core Isolation Cooling (RCIC}

Pump to provide core decay-heat cooling.

The selection of contact devices for the Safety Relief Valves (SRVs) overlaps with the RCS/Reactor Vessel Inventory Control Category. Refer to Section 2.2 for more information on the analysis of contact devices for these valves.

The selection of contact devices for RCIC was based on the premise that RCIC operation is desired, thus any SILO which would lead to RCIC operation is beneficial and thus does not meet the criteria for selection. Only contact devices which could render the RCIC system inoperable were considered.

The largest vulnerability to RCIC operation following a seismic event is contact chatter leading to a false RCIC Isolation Signal or false Turbine Trip. A false steam line break trip has the potential to delay RCIC operation while confirmatory inspections are being made. Chatter in the contacts of RCIC Isolation Signal Relay E51A-K31A or Steam Line High Differential Pressure Time Delay Relay E51A-K15A; or coincident chatter in the Turbine Exhaust Diaphragm High Pressure Relays E51A-K11A and E51A-K12A, or Reactor Pressure Relays E51A-K16A and E51A-K17A; may lead to a RCIC Isolation Signal and seal-in of E51A-K31A [19). This would cause the RCIC Isolation Valves to close and the RCIC Trip and Throttle Valve to trip. Similar chatter in the contact devices that drive those relays could also lead to seal-in: PIS-050-1N655A, PIS-050-1N655E, PIS-049-1N658A, and PIS-049-1N658E (20]. (The three-second time delay associated with E51A-K15A will mask any chatter on PDIS-049-1N657A and PDS-049-1N660A, so they are excluded.) The same rationale applies to the identical Division 3 devices: ES1A-K31C, E51A-K1SC, ESlA-KllC, E51A-K12C, E51A-K16C, ES1A-K17C, PIS-050-1N65SC, PIS-050-1N6SSG, PIS-049-1N658C, and PIS-049-1N658G (21, 22).

Any chatter that may lead to the energization of the Trip and Throttle Valve Remote Trip Circuit is considered as SILO as it will close the valve and require a manual reset prior to restoration of the RCIC system. Chatter in Turbine Trip Auxiliary Relay E51A-K28, or in the devices which control this relay; the Turbine Exhaust High Pressure Relays E51A-K13 and E51A-K14, the Pump Suction Low Pressure Relay ESlA-KlO, and the Isolation Signal Relays E51A-K30A, and E51A-K67C (19).

Similar chatter in the contact devices that drive those relays (and not already covered in the RCIC Isolation Signal analysis) could also lead to a turbine trip: ES1A-K30C, PIS-OS0-1N653, PIS-050-1N656A, and PIS-050-1N656E [20, 21).

Page 11 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 2.5 AC/DC POWER SUPPORT SYSTEMS The AC and DC power support systems were reviewed for contact control devices in seal-in and lockout circuits that prevent the availability of DC and AC power sources. The following AC and DC power support systems were reviewed:

  • Battery Chargers,
  • Inverters,
  • EDG Ancillary Systems, and
  • Switchgear, Load Centers, and MCCs.

Electrical power, especially DC, is necessary to support achieving and maintaining a stable plant condition following a seismic event. DC power relies on the availability of AC power to recharge the batteries. The availability of AC power is dependent upon the Emergency Diesel Generators and their ancillary support systems. EPRI 3002004396 [8] requires confirmation that the supply of emergency power is not challenged by a SILO device. The tripping of lockout devices or circuit breakers is expected to require some level of diagnosis to determine if the trip was spurious due to contact chatter or in response to an actual system fault. The actions taken to diagnose the fault condition could substantially delay the restoration of emergency power.

In order to ensure contact chatter cannot compromise the emergency power system, control circuits were analyzed for the Emergency Diesel Generators (EDG), Battery Chargers, Vital AC Inverters, and Switchgear/Load Centers/MCCs as necessary to distribute power from the EDGs to the Battery Chargers and EDG Ancillary Systems. General information on the arrangement of safety-related AC and DC systems, as well as operation of the EDGs, was obtained from Limerick's UFSAR [90]. Limerick has eight (8) EDGs which provide emergency power for their two units.

Each unit has four (4) divisions of Class lE loads with one EDG for each division [90, pp. 8.1-2].

The Class lE AC distribution scheme is shown on one-line drawings E-15 [91] (Unit 1) and E-16

[92] (Unit 2). The Class lE DC distribution scheme is described in the UFSAR (90, pp. 8.3-38] and shown on one-line drawings E-33 (93, 94] (Unit 1) and E-34 (95, 96] (Unit 2).

The analysis necessary to identify contact devices in this category relies on conservative worse -

case initial conditions and presumptions regarding event progression. The analysis considers the reactor is operating at power with no equipment failures or LOCA prior to the seismic event. The Emergency Diesel Generators are not operating but are available. The seismic event is presumed to cause a Loss of Offsite Power (LOOP) and a normal reactor SCRAM.

In response to bus undervoltage relaying detecting the LOOP, the Class lE control systems must automatically shed loads, start the EDGs, and sequentially load the diesel generators as designed.

Ancillary systems required for EDG operation as well as Class lE battery chargers and inverters must function as necessary. The goal of this analysis is to identify any vulnerable contact devices which could chatter during the seismic event, seal-in or lock-out, and prevent these systems from performing their intended safety-related function of supplying electrical power during the LOOP.

The following sections contain a description of the analysis for each element of the AC/DC Support Systems. Contact devices are identified by description and Unit 1 Division 1 device ID in this narrative, however the analysis applies to the identical components and devices in all divisions of both units. The selected contact devices for both units and all divisions appear in Page 12 of 11 O

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 7-1 of Reference [18] where they are identified by device-specific ID, as indicated on the referenced control schematics.

Emergency Diesel Generators The analysis of the Emergency Diesel Generators, 011, 012, 013, 014, 021, 022, 023, 024, is broken down into the generator protective relaying and diesel engine control. General descriptions of these systems and controls appear in the UFSAR [90, pp. 8.3-13].

Generator Protective Relaying The control circuits for the 152-11507 EOG circuit breaker [97, 98, 99, 100] include 186-115A, 186-115B, 186-115C bus lockout, 186-AG501 differential lockout, 151-AG501 phase overcurrent, and 132-AG501 anti-motoring protective relays. As mentioned above, there is no presumption of LOCA and thus none of these trips would be bypassed by the LOCA auxiliary control circuit.

Chatter in any of these relays may prevent closure of the EOG circuit breaker. The generator differential lockout relay 186-AG501 may be tripped by chatter in the 187G-AG501 differential and 151N-AG501 ground fault protective relays [101] . In addition, chatter in the 187-115 safeguards bus differential protective relays, or the 151-11509, 151-11502 overcurrent and 151N-11509, 151N-11502 ground fault relays associated with primary and alternate power feeds, could lead to the tripping of the bus lockout relay. When tripped, this bus lockout relay prevents closure of the EDG, ESW pump, and load center transformer circuit breakers [102].

The exciter [103] and governor control circuitry [104, 105, 106, 107, 108, 109, 110, 111] was analyzed and no devices within these circuits would cause a sustained change in control state such that the diesel generator would not operate after the period of strong shaking ends. The drawing note associated with an auxiliary contact of exciter contactor Kl, "Trips Generator Circuit Breaker" [104, 105, 106, 107, 108, 109, 110, 111], is not accurate. The as-built condition of this auxiliary contact, connected to TBC terminals 6 and 10, was confirmed by walkdown to be not used . Refer to Attachment 9.4 of Reference [18] for more information regarding this walkdown.

Diesel Engine Control Chatter analysis for the diesel engine control was performed on the start and shutdown circuits of each EDG [112, 113, 114] (Dll), [115, 116, 117] {012), [118, 119, 120] (Dl3), [121, 122, 123]

{014), [124, 125, 126] (D21), [127, 128, 129] (022), [130, 131, 132] (023), [133, 134, 135] {D24).

The start circuit is blocked by seal-in of the SDR engine trouble shutdown or SFR start failure relays. Chatter of the seal-in contacts of these relays or of the contacts of relays within the coil circuits of these relays may prevent EDG start.

The SFR start failure relay is controlled by the two overcrank timing relays, T2A and T2B. Chatter in the contacts of either of these timing relays may energize the start failure relay and once energized it will seal in. The time delay function of these overcrank relays prevent momentary chatter in their coil circuits from energizing them.

The SDR engine trouble shutdown relay is controlled by the EOS engine overspeed switch and EOR engine overspeed relay, the SE emergency stop relay, and a set of three switches and relays for each of the following engine faults: lube oil low pressure (OPLl, OPL2, OPL3, OPl, OP2, OP3),

jacket coolant low pressure (CPLl, CPL2, CPL3, CPl, CP2, CP3), lube oil high temperature {OTHl, OTH2, OTH3, OTl, OT2, OT3), and jacket coolant high temperature (CTHl, CTH2, CTH3, CTl, CT2, CT3) . Chatter of the contacts of the overspeed relay is blocked by the overspeed switch contacts.

Chatter of the overspeed switch could energize the overspeed relay and lead to seal-in of the Page 13of110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 shutdown relay. Chatter in the contacts of the emergency stop relay could lead to seal-in ofthe shutdown relay. Chatter in the emergency stop relay coil circuit is blocked from energizing the emergency stop relay by non-vulnerable control switches. Coincident chatter (occurring in two out of three of each group) on the relays or switches of the lube oil and jacket coolant temperature faults could lead to seal-in of the shutdown relay. Coincident chatter in the lube oil and jacket coolant pressure relay contacts (OPl/2/3, CPl/2/3) may seal-in the shutdown relay.

Since the pressure switches (OPLl/2/3, CPLl/2/3) are closed when the engine is not running, chatter in the T3A engine high speed time delay relay may cause the lube oil low pressure and jacket coolant low pressure relays to energize, which could lead to seal-in of the shutdown relay.

This means that chatter in T3A could prevent engine start regardless of chatter in the pressure switches. For this reason, this time delay relay will be selected and seismically analyzed while the pressure switches will not. If T3A is seismically screened (does not chatter), then chatter in the pressure switches are blocked. If T3A is not seismically screened (could potentially chatter), then the necessary mitigation actions for T3A would also address the potential for chatter in the pressure switches by default.

All other contact devices involved in engine start and engine shutdown circuits were analyzed and, other than the devices noted above, none would cause a sustained change in control state such that the diesel generator would not start after the period of strong shaking ends.

Battery Chargers Chatter analysis on the battery chargers was performed using information from the UFSAR [90]

as well as vendor schematic diagrams [136, 137, 138]. Each battery charger has a high voltage shutdown circuit [90, pp. 8.3-43] which is intended to protect the batteries and DC loads from output overvoltage due to charger failure. The high voltage shutdown circuit has a latching output relay K which disconnects the auxiliary voltage transformer, shutting the charger down

[136, 137]. Chatter in the contacts of this output relay will only have a temporary effect on the charger during the period of strong shaking. The operate coil of this relay is controlled by a non-vulnerable solid-state circuit [138]. No other vulnerable contact device affects the availability of the battery chargers.

Inverters Analysis of schematics for the lA, lB, 2A, and 2B RPS & UPS Static Inverters [139, 140], and the lA, lB, 2A, and 2B APRM UPS Inverters [141, 142] revealed no vulnerable contact devices and thus chatter analysis is unnecessary.

EDG Ancillary Systems In order to start and operate the Emergency Diesel Generators, a number of components and systems are required. For the purpose of identifying electrical contact devices, only systems and components which are electrically controlled are analyzed. Information in the UFSAR [90] was used as appropriate for this analysis.

Starting Air Based on Diesel Generator availability as an initial condition, the passive air reservoirs are presumed pressurized and the only active components in this system required to operate are the air start solenoids [143, 144], which are covered under the EOG engine control analysis in Section above.

Page 14 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Combustion Air Intake and Exhaust The combustion air intake and exhaust for the Diesel Generators are passive systems (145, 146]

which do not rely on electrical control.

Lube Oil The Diesel Generators utilize engine-driven mechanical lubrication oil pumps (147, 148] which do not rely on electrical control.

Fuel Oil The Diesel Generator Fuel Oil System is described in the UFSAR (90, pp. 9.5-28]. The Diesel Generators utilize engine-driven mechanical pumps and DC-powered auxiliary pumps (149, 150]

to supply fuel oil to the engines from the day tanks. The day tanks are re-supplied using AC-powered Diesel Oil Transfer Pumps. Chatter analysis of the control circuits for the electrically-powered auxiliary and transfer pumps (151, 152, 153, 154, 155, 156, 157, 158] concluded they do not include SILO devices. The mechanical pumps do not rely on electrical control.

Cooling Water The Diesel Generator Cooling Water System is described in the UFSAR (90, pp. 9.5-37]. This system consists of two cooling loops, jacket water and air cooler, which are each cooled by Emergency Service Water (ESW) (159, 160, 161, 162]. Engine driven pumps operating in both cooling loops are credited when the engine is operating. These mechanical pumps do not rely on electrical control. The electric jacket water pump is only used during shutdown periods and is thus not included in this analysis.

Four ESW pumps, DA, OB, DC, and OD, provide cooling water to the heat exchangers associated with the eight EDGs (163]. In automatic mode these pumps are started via the EDG Start Signal.

Chatter analysis of the EDG start signal is included in Section above. A chatter analysis of the 152-11508 ESW pump circuit breaker control circuits (164, 165, 166] indicates the 186-115 bus lockout, 150/151-11508 phase overcurrent, and 150G-11508 ground fault relays all could prevent automatic (sequential) breaker closure following the seismic event.

Ventilation The Diesel Generator Enclosure Ventilation System is described in the UFSAR (90, pp. 9.4-46].

Ventilation for each Diesel Generator Enclosure is provided via two exhaust fans (167, 168]. In automatic mode these fans are started via the EDG Start Signal. Chatter analysis of the EDG start signal is included in Section above. Other than SILO devices identified for the EDG start signal, chatter analysis of the control circuits for these fans (169, 170] and their associated dampers concluded they do not include SILO devices.

Switchgear, Load Centers, and MCCs Power distribution from the EDGs to the necessary electrical loads (Battery Chargers, Inverters, Fuel Oil Pumps, and EDG Ventilation Fans) was traced to identify any SILO devices which could lead to a circuit breaker trip and interruption in power. This effort excluded the EDG circuit breakers, which are covered in Section above, and the ESW Pump breakers which are covered in Section above, as well as component-specific contactors and their control devices, which are covered in the analysis of each component above.

Page 15 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 The medium- and low-voltage circuit breakers in 4160V Busses and 440V Load Centers which are supplying power to loads identified in this section have been identified for evaluation. For Unit 1 Division 1 these breakers are 152-11507, 152-11505, 152-11508, 52-20133, and 52-20132 . The 440V AC MCCs use Molded-Case Circuit Breakers (90, pp. 8.3-12] which are seismically rugged [8, pp. 2-11]; and DC power distribution is via non-vulnerable disconnect switches.

The only circuit breakers affected by protective relaying (not already covered) were those that distribute power via stepdown transformers from the 4KV Safeguards Busses to their associated 440V load centers. A chatter analysis of the control circuits for these circuit breakers [171, 172, 173] indicates the 186-115 bus lockout, 150/151-11505 transformer primary phase overcurrent, and 150G-11505 ground fault relays all could prevent automatic (sequential) breaker closure following the seismic event.

2.6

SUMMARY

OF SELECTED COMPONENTS The investigation of high-frequency contact devices as described above was performed in Ref.

[18] . A list of the contact devices requiring a high frequency confirmation is provided in Appendix B, Table B-1. The identified devices are evaluated in Ref. [17] per the methodology/description of Section 3 and 4. Results are presented in Section 5 and Table B-1.

Page16of110

15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 3 Seismic Evaluation 3.1 HORIZONTAL SEISMIC DEMAND Per Reference (8], Sect. 4.3, the basis for calculating high-frequency seismic demand on the subject components in the horizontal direction is the LIM horizontal ground motion response spectrum (GMRS), which was generated as part of the LIM Seismic Hazard and Screening Report

[4] submitted to the NRC on March 31, 2014, and accepted by the NRC on November 6, 2015 (14].

It is noted in Reference [8] that a Foundation Input Response Spectrum (FIRS) may be necessary to evaluate buildings whose foundations are supported at elevations different than the Control Point elevation. However, for sites founded on rock, per Ref. [8], "The Control Point GMRS developed for these rock sites are typically appropriate for all rock-founded structures and additional FIRS estimates are not deemed necessary for the high frequency confirmation effort."

The applicable buildings at LIM are founded on rock; therefore, the Control Point GMRS is representative of the input at the building foundation.

The horizontal GMRS values are provided in Table 3-2.

3.2 VERTICAL SEISMIC DEMAND As described in Section 3.2 of Reference. (8), the horizontal GMRS and site soil conditions are used to calculate the vertical GMRS (VGMRS), which is the basis for calculating high-frequency seismic demand on the subject components in the vertical direction.

The site's soil mean shear wave velocity vs. depth profile is provided in Reference. [4], Table 2.3.2-2 and reproduced below in Table 3-1.

Page 17 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 3-1: Soil Mean Shear Wave Velocity Vs. Depth Profile Depth Depth Thickness, Vs1 Vs30 Layer (m) (ft} d1 (ft) (ft/sec) d1/Vs1 I [ d1 /Vsi] (ft/s) 1 3.048 10.0 10.0 3,452 2.90E-03 2.90E-03 2 6.096 20.0 10.0 3,457 2.89E-03 5.79E-03 3 9.144 30.0 10.0 3,462 2.89E-03 8.68E-03 4 12.192 40.0 10.0 3,467 2.88E-03 1.16E-02 5 15.24 50.0 10.0 3,472 2.88E-03 1.44E-02 3,418 6 18.288 60.0 10.0 3,477 2.88E-03 1.73E-02 7 21.336 70.0 10.0 3,482 2.87E-03 2.02E-02 8 24.384 80.0 10.0 3,487 2.87E-03 2.31E-02 9 27.432 90.0 10.0 3,492 2.86E-03 2.59E-02 10 30.48 100.0 10.0 3,497 2.86E-03 2.88E-02 Using the shear wave velocity vs. depth profile, the velocity of a shear wave traveling from a depth of 30m (98.43ft) to the surface of the site (Vs30) is calculated per the methodology of Reference [8], Section 3.5.

  • The time for a shear wave to travel through each soil layer is calculated by dividing the layer depth (d;) by the shear wave velocity of the layer (Vs;).
  • The total time for a wave to travel from a depth of 30m to the surface is calculated by adding the travel time through each layer from depths of Om to 30m (r[d;/Vs;)).
  • The velocity of a shear wave traveling from a depth of 30m to the surface is therefore the total distance {30m} divided by the total time; i.e., Vs30 = (3Dm}/r[d;/Vs;).
  • Note: The shear wave velocity is calculated based on time it takes for the shear wave to travel 30.48m {lOOft} instead of 30m (98.43ft). This small change in travel distance will have no impact on identifying soil class type.

The site's soil class is determined by using the site's shear wave velocity (Vs30) and the peak ground acceleration (PGA) of the GMRS and comparing them to the values within Reference [8),

Table 3-1. Based on the PGA of 0.193g and the shear wave velocity of 3418ft/s, the site soil class is B-Hard.

Once a site soil class is determined, the mean vertical vs. horizontal GMRS ratios (V/H) at each frequency are determined by using the site soil class and its associated V/H values in Reference

[8], Table 3-2.

The vertical GMRS is then calculated by multiplying the mean V/H ratio at each frequency by the horizontal GMRS acceleration at the corresponding frequency. It is noted that Reference [8],

Table 3-2 values are constant between O.lHz and 15Hz.

The V/H ratios and VG MRS values are provided in Table 3-2 of this report.

Figure 3-1 below provides a plot of the horizontal GMRS, V/H ratios, and vertical GMRS for LIM.

Page 18of110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table 3-2: Horizontal and Vertical Ground Motions Response Spectra Frequency (Hz) HGMRS (g) V/H Ratio VGMRS (g) 100 0.193 0.8 0.154 90 0.195 0.82 0.160 80 0.198 0.87 0.172 70 0.202 0.91 0.184 60 0.210 0.92 0.193 so 0.228 0.9 0.205 45 0.243 0.89 0.216 40 0.258 0.86 0.222 35 0.279 0.81 0.226 30 0.306 0.75 0.230 25 0.339 0.7 0.237 20 0.363 0.68 0.247 15 0.381 0.68 0.259 12.5 0.386 0.68 0 .262 10 0.385 0.68 0 .262 9 0.381 0.68 0 .259 8 0.374 0.68 0.254 7 0.361 0.68 0.245 6 0.340 0.68 0.231 5 0.315 0.68 0.214 4 0.264 0.68 0.180 3.5 0.235 0 .68 0 .160 3 0.203 0.68 0 .138 2.5 0.169 0.68 0.115 2 0.149 0.68 0.101 1.5 0.125 0.68 0.085 1.25 0.106 0.68 0.072 1 0.090 0.68 0.061 0 .9 0 .082 0 .68 0 .056 0.8 0.073 0.68 0.049 0 .7 0.065 0.68 0.044 0.6 0.056 0.68 0.038 0.5 0.046 0.68 0.031 0.4 0.036 0.68 0.025 0 .35 0.032 0 .68 0.022 0.3 0.027 0.68 0.019 0.25 0.023 0.68 0.016 0.2 0.018 0 .68 0.012 0.15 0.014 0.68 0.009 0 .125 0.011 0.68 0.008 0.1 0.009 0.68 0.006 Page19of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 0.50 ---~-.- 1.00

- VG MRS

- HGMRS ,,

0.40 - - V/H Ratio (B-Hard) h -

\

.,. 0 .90

,' \

!9 c

0

':t:i 0.30 L --~1' I

I \

\

~'-, 0 .80 0

".jj RI ex:

t! :c CV Qj ti 0.20 I_ I I ___ .,, 0 .70

~

ct  !-="==-----_._-'- ----

I 0 .10 - - ---- 0 .60 0.00 0 .50 0.1 1 10 100 Frequency [Hz]

Figure 3-1 Plot of the Horizontal and Vertical Ground Motions Response Spectra and V/H Ratios Page 20 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 3.3 COMPONENT HORIZONTAL SEISMIC DEMAND Per Reference [8] the peak horizontal acceleration is amplified using the following two factors to determine the horizontal in-cabinet response spectrum:

  • Horizontal in-structure amplification factor AFsH to account for seismic amplification at floor elevations above the host building's foundation
  • Horizontal in-cabinet amplification factor AFc to account for seismic amplification within the host equipment (cabinet, switchgear, motor control center, etc.)

The in-structure amplification factor AFsH is derived from Figure 4-3 in Reference [8]. The in-cabinet horizontal amplification factor, AFc is associated with a given type of cabinet construction. The three general cabinet types are identified in Reference [8] and Appendix I of EPRI NP-7148-SL [13] assuming 5% in-cabinet response spectrum damping. EPRI NP-7148-SL [13]

classified the cabinet types as high amplification structures such as switchgear panels and other similar large flexible panels, medium amplification structures such as control panels and control room bench board panels and low amplification structures such as motor control centers.

All of the electrical cabinets containing the components subject to high frequency confirmation (see Table B-1 in Appendix B) can be categorized into one of the in-cabinet amplification categories in Reference [8] as follows:

  • Motor Control Centers are typical motor control center cabinets consisting of a lineup of several interconnected sections. Each section is a relatively narrow cabinet structure with height-to-depth ratios of about 4.5 that allow the cabinet framing to be efficiently used in flexure for the dynamic response loading, primarily in the front-to-back direction. This results in higher frame stresses and hence more damping which lowers the cabinet response. In addition, the subject components are not located on large unstiffened panels that could exhibit high local amplifications. These cabinets qualify as low amplification cabinets.
  • Switchgear cabinets are large cabinets consisting of a lineup of several interconnected sections typical of the high amplification cabinet category. Each section is a wide box-type structure with height-to-depth ratios of about 1.5 and may include wide stiffened panels. This results in lower stresses and hence less damping which increases the enclosure response . Components can be mounted on the wide panels, which results in the higher in-cabinet amplification factors.
  • Control cabinets are in a lineup of several interconnected sections with moderate width.

Each section consists of structures with height-to-depth ratios of about 3 which results in moderate frame stresses and damping. The response levels are mid-range between MCCs and switchgear and therefore these cabinets can be considered in the medium amplification category.

3.4 COMPONENT VERTICAL SEISMIC DEMAND The component vertical demand is determined using the peak acceleration of the VG MRS between 15 Hz and 40 Hz and amplifying it using the following two factors:

  • Vertical in-structure amplification factor AFsv to account for seismic amplification at floor elevations above the host building's foundation Page 21of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177

  • Verti cal in-cabinet amplification factor AFc to account for seismic amplification within the host equipment (cabinet, switchgear, motor control center, etc.)

The in-structure amplification factor AFsv is derived from Figure 4-4 in Reference [8]. The in-cabinet vertical amplification factor, AFc is derived in Reference [8] and is 4.7 for all cabinet types.

Page 22of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 4 Contact Device Evaluations Per Reference [8], seismic capacities (the highest seismic test level reached by the contact device without chatter or other malfunction) for each subject contact device are determined by the following procedures:

(1) If a contact device was tested as part of the EPRI High Frequency Testing program [7],

then the component seismic capacity from this program is used.

(2) If a contact device was not tested as part of [7], then one or more of the following means to determine the component capacity were used:

(a) Device-specific seismic test reports (either from the station or from the SQURTS testing program.

(b) Generic Equipment Ruggedness Spectra (GERS) capacities per [9], [10], [11], and [12].

(c) Assembly (e.g. electrical cabinet) tests where the component functional performance was monitored.

The high-frequency capacity of each device was evaluated with the component mounting point demand from Section 3 using the criteria in Section 4.5 of Reference [8]

A summary of the high-frequency evaluation conclusions is provided in Table B-1 in Appendix B of this report.

Page 23 of 11 o

15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 5 Conclusions 5.1 GENERAL CONCLUSIONS LIM has performed a High Frequency Confirmation evaluation in response to the NRC's 50.54(f) letter [1] using the methods in EPRI report 3002004396 [8].

The evaluation identified a total of 528 components that required evaluation. As summarized in Table B-1 in Appendix B, all of the devices have adequate seismic capacity for the reevaluated seismic hazard [4] .

5.2 IDENTIFICATION OF FOLLOW-UP ACTIONS No follow-up actions were identified.

Page 24of110

15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 6 References 1 NRC (E. Leeds and M . Johnson) Letter to All Power Reactor Licensees et al., "Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f} Regarding Recommendations 2.1, 2.3 and 9.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident," March 12, 2012, ADAMS Accession Number ML12053A340 2 NRC (W. Dean) Letter to the Power Reactor Licensees on the Enclosed List. "Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54{f} Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident." October 27, 2015, ADAMS Accession Number ML15194A015 3 NRC (J. Davis) Letter to Nuclear Energy Institute (A. Mauer). "Endorsement of Electric Power Research Institute Final Draft Report 3002004396, 'High Frequency Program :

Application Guidance for Functional Confirmation and Fragility."' September 17, 2015, ADAMS Accession Number ML15218A569 4 Seismic Hazard and Screening Report in Response to the 50.54{f) Information Request Regarding Fukushima Near-Term Task Force Recommendation 2.1: Seismic for Limerick Generating Station, Unit 1 and 2 dated March 31, 2014, ADAMS Accession Number ML14090A236 5 Not Used 6 EPRI 1025287, "Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details (SPID} for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1:

Seismic." February 2013 7 EPRI 3002002997, "High Frequency Program: High Frequency Testing Summary."

September 2014 8 EPRI 3002004396, "High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation ." July 2015 9 EPRI NP-7147-SL, "Seismic Ruggedness of Relays." August 1991 10 EPRI NP-7147-SLV2, Addendum 1, "Seismic Ruggedness of Relays", September 1993 11 EPRI NP-7147-SLV2, Addendum 2, "Seismic Ruggedness of Relays", April 1995 12 EPRI NP-7147 SQUG Advisory 2004-02, "Relay GERS Corrections." September 10, 2004 13 EPRI NP-7148-SL, "Procedure for Evaluating Nuclear Power Plant Relay Seismic Functionality", 1990 14 NRC {F. Vega) Letter to Limerick Generating Station (B. Hanson), "Limerick Generating Station, Unit 1 and 2 - Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54{f), Seismic Hazard Reevaluations for Recommendation 2.1 ofthe Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident (TAC NOS. MF3864 and MF3865)." November 6, 2015, ADAMS Accession Number ML15296A492 15 Recommendations For Enhancing Reactor Safety in the 21' 1 Century, "The Near-Term Task Force Review of Insights from the Fukushima Dai-I chi Accident" July 12, 2011, ADAMS Accession Number ML111861807 16 NEI 12-06, Rev. 2, "Diverse and Flexible Coping Strategies {FLEX) Implementation Guide" Page 25 of 11 O

1SC434S-RPT-002, Rev. 0 Correspondence No.: RS-16-177 17 1SC434S-CAL-001, Rev. 2, "High Frequency Functional Confirmation and Fragility Evaluation of Relays" 18 1SC434S-RPT-001, Rev. 3, "Selection of Relays and Switches for High Frequency Seismic Evaluation" 19 Limerick Drawing ESl-1040-E-003 Rev. 32, Elementary Diagram Reactor Core Isolation 20 Limerick Drawing ESl-1040-E-013 Rev. 16, Elementary Diagram RCIC System Sheet 3A 21 Limerick Drawing ESl-1040-E-004 Rev. 30, Elementary Diagram Reactor Core Isolation 22 Limerick Drawing ESl-1040-E-014 Rev. 16, Elementary Diagram RCIC System Sheet 4A 23 Limerick Drawing M-0041Sheet1Rev.47, Piping and Instrument Diagram Nuclear Boiler 24 Limerick Drawing M-0041 Sheet 3 Rev. SS, Piping and Instrument Diagram Nuclear Boiler 2S Limerick Drawing M-0041Sheet4 Rev. 43, Piping and Instrument Diagram Nuclear Boiler 26 Limerick Drawing M-0041 Sheet 6 Rev. SS, Piping and Instrument Diagram Nuclear Boiler 27 Limerick Drawing B21-1060-E-004 Rev. 14, Elementary Diagram Automatic De pressurization System Sheet 4 28 Limerick Drawing B21-1060-E-OOS Rev. 13, Elementary Diagram Automatic Depressurization System Sheet S 29 Limerick Drawing B21-1060-E-018 Rev. 7, Elementary Diagram Automatic Depressurization System 30 Limerick Drawing B21-1060-E-019 Rev. 6, Elementary Diagram Automatic Depressurization System 31 Limerick Drawing B21-1060-E-003 Rev. 16, Elementary Diagram Automatic Depressurization System 32 Limerick Drawing B21-1060-E-01S Rev. S, Elementary Diagram Auto Depressurization System 33 Limerick Drawing B21-1060-E-008 Rev. 14, Elementary Diagram Auto Depressurization System Sheet 3A 34 Limerick Drawing B21-1060-E-016 Rev. 4, Elementary Diagram Auto Depressurization System Sheet 3A 3S Limerick Drawing B21-1060-E-006 Rev. 19, Elementary Diagram Auto Depressurization System Sheet 6 36 Limerick Drawing B21-1060-E-011Rev.12, Elementary Diagram Auto Depressurization System Sheet 6A 37 Limerick Drawing B21-1060-E-020 Rev. 7, Elementary Diagram Auto Depressurization System 38 Limerick Drawing B21-1060-E-021 Rev. 6, Elementary Diagram Auto Depressurization System 39 Limerick Drawing B21-1090-E-010 Rev. 23, Elementary Diagram Nuclear Steam Supply Shutoff System 40 Limerick Drawing B21-1090-E-011 Rev. 23, Elementary Diagram Nuclear Steam Supply Shutoff System 41 Limerick Drawing B21-1090-E-027 Sheet 10 Rev. 8, Elementary Diagram Reactor Core Isolation 42 Limerick Drawing B21-1090-E-027 Sheet 11 Rev. 9, Elementary Diagram Nuclear Steam Supply Shutoff System Page 26 of 11 O

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 43 Limerick Drawing B21-1090-E-006 Rev. 27, Elementary Diagram Nuclear Steam Supply Shutoff System Sheet 6 44 Limerick Drawing B21-1090-E-007 Rev. 25, Elementary Diagram Nuclear Steam Supply Shutoff System Sheet 7 45 Limerick Drawing B21-1090-E-027 Sheet 6 Rev. 7, Elementary Diagram Nuclear Steam Supply Shutoff System 46 Limerick Drawing B21-1090-E-027 Sheet 7 Rev. 8, Elementary Diagram Nuclear Steam Supply Shutoff System 47 Limerick Drawing B21-1040-E-004 Rev. 23, Elementary Diagram Nuclear Boiler Process 48 Limerick Drawing B21-1040-E-008 Rev. 8, Elementary Diagram Nuclear Boiler Process 49 Limerick Drawing B21-1040-E-009 Rev. 9, Elementary Diagram Nuclear Boiler Process 50 Limerick Drawing B21-1090-E-032 Sheet 1 Rev. l, HV-041-1F016 Main Steam Drain Inboard PCIV Steam Drains Inboard 51 Limerick Drawing B21-1090-E-038 Sheet 1 Rev. 0, Elementary Diagram HV-051-2F016 52 Limerick Drawing G31-1040-E-001 Rev. 46, Elementary Diagram Reactor Water Cleanup System 53 Limerick Drawing G31-1040-E-005 Rev. 24, Elementary Diagram Reactor Water Cleanup System 54 Limerick Drawing B21-1090-E-012 Rev. 29, Elementary Diagram Nuclear Steam Supply Shutoff System 55 Limerick Drawing B21-1090-E-016 Sheet 2 Rev. 4, Elementary Diagram Nuclear Steam Supply Shutoff System 56 Limerick Drawing B21-1090-E-027 Sheet 12 Rev. 16, Elementary Diagram Nuclear Steam Supply Shutoff System 57 Limerick Drawing B21-1090-E-027 Sheet 2A Rev. 15, Elementary Diagram Nuclear Steam Supply Shutoff System 58 Limerick Drawing B21-1090-E-008 Rev. 32, Elementary Diagram Nuclear Steam Supply Sheet 8 59 Limerick Drawing B21-1090-E-017 Rev. 33, Elementary Diagram Nuclear Steam Supply Sheet 8A 60 Limerick Drawing B21-1090-E-027 Sheet 8 Rev. 16, Elementary Diagram Nuclear Steam Supply Shutoff System 61 Limerick Drawing B21-1090-E-027 Sheet 8A Rev. 14, Elementary Diagram Nuclear Steam Supply Shutoff System 62 Limerick Drawing ESl-1040-E-052 Sheet 1 Rev . l, Schematic HV-049-1F007 Main Steam Supply Inboard PCIV Inboard 63 Limerick Drawing ESl-1040-E-053 Sheet 1 Rev. 2, Schematic HV-049-1F008 RCIC Steam Line Outboard PCIV Outboard 64 Limerick Drawing ESl-1040-E-056 Sheet 1Rev.1, Elementary Diagram HV-049-2F007 65 Limerick Drawing ESl-1040-E-057 Sheet 1 Rev. 1, Elementary Diagram HV-049-2F008 66 Limerick Drawing Ell-1040-E-016 Rev. 35, Elementary Diagram Residual Heat Removal System 67 Limerick Drawing Ell-1040-E-018 Rev. 35, Elementary Diagram Residual Heat Removal System Page 27 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 68 Limerick Drawing Ell-1040-E-019 Rev. 32, Elementary Diagram Residual Heat Removal System 69 Limerick Drawing Ell-1040-E-020 Rev. 23, Elementary Diagram Residual Heat Removal System 70 Limerick Drawing Ell-1040-E-021 Rev. 21, Elementary Diagram Residual Heat Removal System 71 Limerick Drawing Ell-1040-E-049 Rev. 17, Elementary Diagram Residual Heat Removal System 72 Limerick Drawing Ell-1040-E-051Rev.16, Elementary Diagram Residual Heat Removal System 73 Limerick Drawing Ell-1040-E-052 Rev. 15, Elementary Diagram Residual Heat Removal System 74 Limerick Drawing Ell-1040-E-053 Rev. 10, Elementary Diagram Residual Heat Removal System 75 Limerick Drawing Ell-1040-E-054 Rev. 11, Elementary Diagram Residual Heat Removal System 76 Limerick Drawing B21-1090-E-018 Sheet 2 Rev. 4, Elementary Diagram Nuclear Steam Supply Shutoff System 77 Limerick Drawing B21-1090-E-033 Sheet 1Rev.1, Schematic HV-051-1F009 RHR Shutdown Cooling Suction Inboard PCI Inboard 78 Limerick Drawing B21-1090-E-034 Sheet 1 Rev. 1, Elementary Diagram HV-051-2F008 79 Limerick Drawing B21-1090-E-035 Rev. 1, Elementary Diagram HV-051-2F009 80 Limerick Drawing E21-1040-E-009 Rev. 25, Elementary Diagram Core Spray System 81 Limerick Drawing E21-1040-E-010 Rev. 22, Elementary Diagram Core Spray System 82 Limerick Drawing E21-1040-E-030 Rev. 9, Elementary Diagram Core Spray System 83 Limerick Drawing E21-1040-E-031 Rev. 8, Elementary Diagram Core Spray System 84 Limerick Drawing E41-1040-E-014 Sheet 2 Rev. 1, Elementary Diagram HPCI System 85 Limerick Drawing E41-1040-E-013 Sheet 2 Rev. 0, Elementary Diagram HPCI System 86 Limerick Drawing E41-1040-E-027 Sheet 2 Rev. 0, Elementary Diagram HPCI System Sheet 11 87 Limerick Drawing E41-1040-E-027 Sheet 6 Rev. 0, Elementary Diagram HPCI System 88 Limerick Drawing E41-1040-E-006 Rev. 36, Elementary Diagram HPCI System 89 Limerick Drawing E41-1040-E-022 Rev. 8, Elementary Diagram HPCI System 90 Limerick Report, "Updated Final Safety Analysis Report (UFSAR)," Rev. 18, September 2016 91 Limerick Drawing E-0015 Sheet 1 Rev. 30, Single Line Meter and Relay Diagram 4KV Safeguard Power System Unit 1 92 Limerick Drawing E-0016 Sheet 1 Rev. 26, Single Line Meter and Relay Diagram 4KV Safeguard Power System Unit 2 93 Limerick Drawing E-0033 Sheet 1 Rev. 45, Single Line Meter and Relay Diagram 125, 250VDC System 94 Limerick Drawing E-0033 Sheet 2 Rev. 47, Single Line Meter and Relay Diagram 125, 250VDC System 95 Limerick Drawing E-0034 Sheet 1 Rev. 38, Single Line Meter and Relay Diagram 125, 250V DC System Page 28 of 11 O

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 96 Limerick Drawing E-0034 Sheet 2 Rev. 40, Single Line Diagram Instrumentation AC System 97 Limerick Drawing E-0164 Sheet 1 Rev. 19, Safeguard Busses Dll thru D14, D21 thru D24 Generator Breakers 4KV 98 Limerick Drawing E-0164 Sheet 3 Rev. 10, Safeguard Busses Dll thru D14 and D21 thru D24 Generator Breakers 4KV 99 Limerick Drawing E-0164 Sheet 5 Rev. 9, Safeguard Busses Dll thru D14 Generator Breakers 4KV 100 Limerick Drawing E-0164 Sheet SA Rev. 1, Schematic Diagram Safeguard Busses D21, 22, 23, 24 Generator Breakers 4KV Unit 2 101 Limerick Drawing E-0169 Sheet 1 Rev. 11, Schematic Diagram - Diesel Generator Protective 102 Limerick Drawing E-0168 Sheet 1 Rev. 6, Schematic Diagram - Safeguard Buses, Protective Relaying 103 Limerick Drawing M-071-00147 Sheet 1 Rev. 21, Schematic Power Chassis Nuclear Exciter/Regulator 104 Limerick Drawing M-071-00065 Sheet lA Rev. 19, Control Schematic Dll Diesel Generator 105 Limerick Drawing M-071-00065 Sheet 6 Rev. 2, Control Schematic D12 Diesel Generator 106 Limerick Drawing M-071-00065 Sheet 12 Rev. 3, Control Schematic D13 Diesel Generator 107 Limerick Drawing M-071-00065 Sheet 18 Rev. 3, Control Schematic D14 Diesel Generator 108 Limerick Drawing M-071-00065 Sheet 24 Rev. 3, Control Schematic D21 Diesel Generator 109 Limerick Drawing M-071-00065 Sheet 30 Rev. 3, Control Schematic D22 Diesel Generator 110 Limerick Drawing M-071-00065 Sheet 36 Rev. 2, Control Schematic D23 Diesel Generator 111 Limerick Drawing M-071-00065 Sheet 42 Rev. 3, Control Schematic D24 Diesel Generator 112 Limerick Drawing M-071-00048 Sheet 1 Rev. 30, Schematic Engine Control Dll Diesel Generator 113 Limerick Drawing M-071-00048 Sheet 2 Rev. 32, Schematic Engine Control Dll Diesel Generator 114 Limerick Drawing M-071-00048 Sheet 3 Rev. 33, Schematic Engine Control Dll Diesel Generator 115 Limerick Drawing M-071-00048 Sheet 6 Rev. 14, Schematic Engine Control D12 Diesel Generator 116 Limerick Drawing M-071-00048 Sheet 7 Rev. 3, Schematic Engine Control D12 Diesel Generator 117 Limerick Drawing M-071-00048 Sheet 8 Rev. 1, Schematic Engine Control D12 Diesel Generator 118 Limerick Drawing M-071-00048 Sheet 11Rev.0, Schematic Engine Control D13 Diesel Generator 119 Limerick Drawing M-071-00048 Sheet 12 Rev. 3, Schematic Engine Control D13 Diesel Generator 120 Limerick Drawing M-071-00048 Sheet 13 Rev. 1, Schematic Engine Control D13 Diesel Generator 121 Limerick Drawing M-071-00048 Sheet 16 Rev. 0, Schematic Engine Control D14 Diesel Generator 122 Limerick Drawing M-071-00048 Sheet 17 Rev. 3, Schematic Engine Control D14 Diesel Generator Page 29of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 123 Limerick Drawing M-071-00048 Sheet 18 Rev. 1, Schematic Engine Control D14 Diesel Generator 124 Limerick Drawing M-071-00048 Sheet 21 Rev. 0, Schematic Engine Control D21 Diesel Generator 125 Limerick Drawing M-071-00048 Sheet 22 Rev. 3, Schematic Engine Control D21 Diesel Generator 126 Limerick Drawing M-071-00048 Sheet 23 Rev. 1, Schematic Engine Control D21 Diesel Generator 127 Limerick Drawing M-071-00048 Sheet 26 Rev. 0, Schematic Engine Control D22 Diesel Generator 128 Limerick Drawing M-071-00048 Sheet 27 Rev. 3, Schematic Engine Control D22 Diesel Generator 129 Limerick Drawing M-071-00048 Sheet 28 Rev. 1, Schematic Engine Control D22 Diesel Generator 130 Limerick Drawing M-071-00048 Sheet 31 Rev. 0, Schematic Engine Control D23 Diesel Generator 131 Limerick Drawing M-071-00048 Sheet 32 Rev. 3, Schematic Engine Control D23 Diesel Generator 132 Limerick Drawing M-071-00048 Sheet 33 Rev. 1, Schematic Engine Control D23 Diesel Generator 133 Limerick Drawing M-071-00048 Sheet 36 Rev. 0, Schematic Engine Control D24 Diesel Generator 134 Limerick Drawing M-071-00048 Sheet 37 Rev. 3, Schematic Engine Control D24 Diesel Generator 135 Limerick Drawing M-071-00048 Sheet 38 Rev. 1, Schematic Engine Control D24 Diesel Generator 136 Limerick Drawing E-017-00012 Sheet 1Rev.11, Diagram - Schematic Arrangement 130 K300 and 400 Chargers 137 Limerick Drawing E-017-00014 Sheet 1 Rev. 9, Diagram - Schematic Arrangement 130 HK75/100F3 Chargers 138 Limerick Drawing E-017-00065 Sheet 1 Rev. 2, High Voltage Shutdown with Time Delay Universal PC Board 139 Limerick Drawing E-0032 Sheet 1 Rev. 64, Single Line Meter and Relay Diagram Uninterruptible AC, RPS, UPS, Computer 140 Limerick Drawing N-OOE-72-00010 Sheet 1Rev.1, Power Stage Wiring 30KVA Inverter Solid State Switch 1AD160 141 Limerick Drawing E-0032 Sheet 2 Rev. 39, Single Line Meter and Relay Diagram Un interruptible AC System 142 Limerick Drawing N-OOE-72-00015 Sheet 1 Rev. 1, Power Stage Wiring 30KVA Inverter Solid State Switch 1BD160 143 Limerick Drawing M-0020 Sheet 6 Rev. 52, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Starting Air System Unit 1) 144 Limerick Drawing M-0020 Sheet 12 Rev. 16, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Starting Air System Unit 2)

Page 30of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 145 Limerick Drawing M-0020 Sheet 8 Rev. 23, Piping and Instrument Diagram Fuel and Diesel Oil Storange and Transfer (Combustion Air Intake and Exhaust System Unit 1) 146 Limerick Drawing M-0020 Sheet 14 Rev. 15, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Combustion Air Intake and Exhaust System Unit 2) 147 Limerick Drawing M-0020 Sheet 7 Rev. 53, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Lube Oil System Unit 1) 148 Limerick Drawing M-0020 Sheet 13 Rev. 18, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Lube Oil System Unit 2) 149 Limerick Drawing M-0020 Sheet 3 Rev. 39, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Fuel Oil and Transfer System Unit 1) 150 Limerick Drawing M-0020 Sheet 9 Rev . 17, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Fuel Oil and Transfer System Unit 2) 151 Limerick Drawing M-071-00048 Sheet 5 Rev. 21, Schematic Engine Control Dll Diesel Generator 152 Limerick Drawing M-071-00048 Sheet 10 Rev. 1, Schematic Engine Control D12 Diesel Generator 153 Limerick Drawing M-071-00048 Sheet 15 Rev. 1, Schematic Engine Control D13 Diesel Generator 154 Limerick Drawing M-071-00048 Sheet 20 Rev. 1, Schematic Engine Control D14 Diesel Generator 155 Limerick Drawing M-071-00048 Sheet 25 Rev. 1, Schematic Engine Control D21 Diesel Generator 156 Limerick Drawing M-071-00048 Sheet 30 Rev. 1, Schematic Engine Control D22 Diesel Generator 157 Limerick Drawing M-071-00048 Sheet 35 Rev. 1, Schematic Engine Control 023 Diesel Generator 158 Limerick Drawing M-071-00048 Sheet 40 Rev. 1, Schematic Engine Control 024 Diesel Generator 159 Limerick Drawing M-0020 Sheet 4 Rev. 46, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 1) 160 Limerick Drawing M-0020 Sheet 5 Rev. 44, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 1) 161 Limerick Drawing M -0020 Sheet 10 Rev. 51, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Coling Water System Unit 2) 162 Limerick Drawing M-0020 Sheet 11 Rev. 8, Piping and Instrument Diagram Fuel and Diesel Oil Storage and Transfer (Cooling Water System Unit 2) 163 Limerick Drawing M -0011Sheet1 Rev. 86, Piping and Instrument Diagram Emergency Service Water (Unit 1, Unit 2, and Common) 164 Limerick Drawing E-0321 Sheet 2 Rev. 19, Schematic Diagram Emergency Service Water Pumps 165 Limerick Drawing E-0321Sheet3 Rev. 19, Schematic Diagram Emergency Service Water Pumps 166 Limerick Drawing E-0321Sheet5 Rev. 17, Schematic Diagram Emergency Service Water Pumps Page 31of110

15C4345-RPT-002, Rev. 0 Correspondence No .: RS-16-177 167 Limerick Drawing M-0081Sheet1 Rev. 31, Piping and Instrument Diagram Miscellaneous Structures HVAC 168 Limerick Drawing M-0081 Sheet 3 Rev. 15, Piping and Instrument Diagram Miscellaneous Structures HVAC (Unit 2 and Common) 169 Limerick Drawing E-0490 Sheet 1 Rev. 16, Schematic Diagram Diesel Generator Ventilation Air Exhaust Fans and Auxiliary Control Units 1 and 2 170 Limerick Drawing E-0490 Sheet 2 Rev. 10, Schematic Diagram Diesel Generator Ventilation Air Exhaust Fans and Auxiliary Control Units 1 and 2 171 Limerick Drawing E-0163 Sheet 1 Rev. 18, Schematic Diagram - Safeguard Buses - Safeguard Load Center 172 Limerick Drawing E-0163 Sheet 2 Rev. 3, Schematic Diagram - Safeguard Buses - Safeguard Load Center 173 Limerick Drawing E-0162 Sheet 1Rev.13, Schematic Diagram-Safeguard Buses - Dl44 and D244 Page 32of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 A Representative Sample Component Evaluations The following sample calculation is extracted from Reference [17).

Notes:

1. Reference citations within the sample calculation are per the Ref. [17) reference section shown on the following page .
2. This sample calculation contains evaluations of sample high-frequency-sensitive components per the methodologies of both the EPRI high-frequency guidance [8) and the flexible coping strategies guidance document NEI 12-06 [16).

Page 33 of 11 O

15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 S&A Cale. No.: 15C4345-CAL-001, Rev. 2 Sheet 9 of 20

Title:

High Frequency Functional Confirmation and Prepared: FG Date: 10/27/16 Fragility Evaluation of Components Reviewed: MD Date: 10/27/16 St""""""1&Aisociates 6 REFERENCES

1. Codes. Guidance. and Standards 1.1. EPRI 3002004396. " High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation ." July 2015.

1.2. EPRI 3002002997. "High Frequency Program : High Frequency Testing Summary." September 2014.

1.3. Not Used 1.4. NEI 12-06, Appendix H, Rev. 2, "Diverse and Flexible Coping Strategies (FLEX) Implementation Guide."

1.5. IEEE 344-1975 "IEEE Recommended Practices for Seismic Qualification of Class lE Equipment for Nuclear Power Generating Stations" 1.6. SQUG GIP 3A, "Generic Implementation Procedure (GIP) for Seismic Verification of Nuclear Plant Equipment", December 2001 1.7. EPRI NP-7147-SL, "Seismic Ruggedness of Relays", August 1991 1.8. EPRI NP-7147-SL, SQUG Advisory 2004-02. "Relay GERS Corrections", September 10, 2004 1.9. EPRI NP-7147-SLV2, Addendum 1, "Seismic Ruggedness of Relays", September 1993 1.10. ANSI/IEEE C37.98-1987, "An American National Standard IEEE Standard Seismic Testing of Relays."

January 15, 1988 1.11. EPRI NP-6041-SL, Rev. 1, "A Methodology for Assessment of Nuclear Power Plant Seismic Margin",

August 1991 1.12. EPRI NP-7147-SLV2, Addendum 2, "Seismic Ruggedness of Relays", April 1995

2. Nuclear Regulatory Commission Documents 2.1. Limerick Generating Station Units 1 & 2 Seismic Hazard and Screening Report, Rev. 0, NRC Docket No.

STN 50-352 & STN 50-353, Correspondence No. RS-14-069

3. Station Documents 3.1. Limerick Drawing C-0409, Rev. 33, "Control Room Area, Foundations, Wall Elevations Area 8" 3.2 . General Electric Report GE-101, Rev. 2, "GE Dynamic Qualification Report for Class lE Control Room Panels" 3.3. General Electric Report GE-201, Rev. 2, "GE Dynamic Qualification Report for Class lE Control Room Panels" 3.4. Limerick Drawing C-0682, Rev. 11, "Diesel Generator Building Unit 2 Wall Elevation & Sections" 3.5. Limerick Report D-0014, Rev. 7, "Dynamic Qualification Book", Volumes 1-3.

3.6. Limerick Report D-0007, Rev. 10, "Dynamic Qualification Book", Volumes 1-2.

3.7 . Not Used 3.8. Limerick Report D-0015, Rev. 12, "Dynamic Qualification Book", Volumes 1-4.

4. S&A Documents 4.1. 15C4345-RPT-001, Rev. 3, "Selection of Relays and Switches for High Frequency Seismic Evaluation."
5. Other Documents 5.1. TE Connectivity, Qualification Test Report 501-529, "Nuclear Environmental Qualification Test Report on Agastat EGP, EML and ETR Control Relays by Control Products Division, Amerace Corporation" 5.2 . GE Multilin IAC Time-Overcurrent Brochure, "Time-overcurrent protection of AC circuits and apparatus." (See Attachment E) 5.3 . Agastat Nuclear Qualified Control Relays, dated 4/24/2002 "Series EGP/EML/ETR" (See Attachment F)

Page 34 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No. : 1SC4345-CAL-001, Rev. 2 Sheet 12 of 20 Title : High Frequency Functional Confirmation and Prepared : FG Date: 10/27/16 Fragility Evaluation of Components Reviewed : MD Date: 10/27/16 Stevenson & As.scxiates 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand Calculate the high-frequency seismic demand on the components per the methodology from Ref. 1.1 .

Sample calculations for the high-frequency seismic demand of components PIS-050-1 N653 located in Unit 1 and E51A-K10 located in Unit 1 are presented below. A table that calculates the high-frequency seismic demand for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A , Table A-2 of this calculation.

8.2.1 Horizontal Seismic Demand The horizontal site-specific GMRS for Limerick is per Ref. 2.1. GMRS data can be found in Attachment B of this calculation.

Determine the peak acceleration of the horizontal GMRS between 15 Hz and 40 Hz .

Peak acceleration of horizontal GMRS S~MRS := 0.381 g (at 15 Hz) between 15 Hz and 40 Hz (Ref. 2.1; see Attachment B of this calculation):

Calculate the horizontal in-structure amplification factor based on the distance between the bottom of the foundation elevation and the subject floor elevation.

Bottom of Deepest Foundation Elevation : Elfound := 174 *ft (Ref. 2.1, Table 2.3.1-1, Note C)

Component Floor Elevation (See Table A-1 ): Elcomp :- 289 *ft Components PIS-050-1 N653 and E51A-K10 are both located in the Control Enclosure building at elevation 289'.

Distance Between Component Floor and hcomp := ELcomp - Elfound - 115.00 *ft Foundation Elevation:

Page 35 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2 Sheet 13 of 20

Title:

High Frequency Functional Confirmation and Prepared : FG Date: 10/27/16 Fragility Evaluation of Components Reviewed: MD Date: 10/27/16 Stevenson & A5scc:iates 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd)

B.2.1 Horizontal Seismic Demand (cont'd)

Work the distance between the component floor and foundation with Ref. 1.1, Fig. 4-3 to calculate the horizontal in-structure amplification factor.

2.1 - 1.2 1 Slope of Amplification Factor Line, mh := = 0.0225 *-

Oft < hcomp < 4Dft 40ft - Oft ft Intercept of Amplification Factor Line, Oft < hcomp < 40ft Horizontal In-Structure Amplification Factor:

AF SH(hcomp) := I(mh

  • hcomp + bh) if hcomp 2.1 otherwise s 40ft Calculate the horizontal in-cabinet amplification factor based on the type of cabinet that contains the subject component.

Type of Cabinet (per Ref. 3.2 and 3.3) cab := "Control Cabinet" (enter "MCC", "Switchgear", "Control Cabinet", or "Rigid"):

Horizontal In-Cabinet Amplification Factor AFc.h(cab) := 3.6 if cab= "MCC" (Ref. 1.1, p. 4-13):

7.2 if cab = "Switchgear" 4.5 if cab = "Control Cabinet" 1.0 if cab = "Rigid" AFc.h(cab) = 4.5 Multiply the peak horizontal GMRS acceleration between by the horizontal in-structure and in-cabinet amplification factors to determine the in-cabinet response spectrum demand on the components .

Horizontal In-Cabinet Response Spectrum (Ref. 1.1, p. 4-12, Eq . 4-1a):

Note that the horizontal seismic demand is the same for both components PIS-050-1 N653 and E51A-K10.

Page 36 of 110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2 Sheet 14 of 20

Title:

High Frequency Functional Confirmation and Prepared: FG Date : 10/27/16 Fragility Evaluation of Components Reviewed: MD Date: 10/27/16 Stevenson & As.scciiltes 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd)

B.2.2 Vertical Seismic Demand Determine the peak acceleration of the horizontal GMRS between 15 Hz and 40 Hz.

Peak Acceleration of Horizontal GMRS S~MRS - 0.381 .g (at 15 Hz)

Between 15 Hz and 40 Hz (See Sect. 8. 2.1 of this Calculation)

Obtain the peak ground acceleration (PGA) of the horizontal GMRS from Ref. 2.1 (See Attachment B of this calculation).

Peak Ground Acceleration (GMRS): PGAGMRS :"" 0.193g Calculate the shear wave velocity traveling from a depth of 30m to the surface of the site 01 530 ) from Ref. 1.1 and Attachment C.

(30m)

Shear Wave Velocity:

Vs30 = 1:( di .)

VSI where, di: Thickness of the layer (ft)

V si: Shear wave velocity of the layer (ft/s)

Per Attachment C, the sum of thickness of the layer over shear wave velocity of the layer is 0.0288 sec.

30m ft Shear Wave Velocity: v  := = 3418 *-

s3o 0.028Bsec sec Page 37 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA Stevenson & Associates S&A Cale. No.: 15C4345-CAL-001, Rev. 2

Title:

High Frequency Functional Confirmation and Fragility Evaluation of Components Prepared : FG Reviewed: MD Sheet 15 of 20 Date: 10/27/16 Date: 10/27/16 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd) 8.2.2 Vertical Seismic Demand (cont'd)

Work the PGA and shear wave velocity with Ref. 1.1, Table 3-1 to determine the soil class of the site. Based on the PGA of 0.1939 and shear wave velocity of 3418ft/sec at Limerick, the site soil class is B-Hard.

Work the site soil class with Ref. 1.1, Table 3-2 to determine the mean vertical vs. horizontal GMRS ratios (V/H) at each spectral frequency. Multiply the V/H ratio at each frequency between 15Hz and 40Hz by the corresponding horizontal GMRS acceleration at each frequency between 15Hz and 40Hz to calculate the vertical GMRS .

See Attachment B for a table that calculates the vertical GMRS (equal to (V/H) x horizontal GMRS) between 15Hz and 40Hz.

Determine the peak acceleration of the vertical GMRS (SAvGMRs) between frequencies of 15Hz and 40Hz. (By inspection of Attachment B, the SAvGMRs occurs at 15Hz.)

V/H Ratio at 15Hz VH := 0.68 (See Attachment B of this calculation):

Horizontal GMRS at Frequency of Peak HGMRS :- 0.3819 Vertical GMRS (at 15Hz)

(See Attachment B of this calculation):

Peak Acceleration of Vertical GMRS SAvGMRS := VH *HGMRS -= 0.259*9 (at 15 Hz)

Between 15 Hz and 40 Hz:

A plot of horizontal and vertical GMRS is provided in Attachment B of this calculation.

Page 38 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 15C4345-CAL-001, Rev. 2 Sheet 16 of 20 Title : High Frequency Functional Confirmation and Prepared : FG Date: 10/27/16 Fragility Evaluation of Components Reviewed : MD Date: 10/27/16 Stevenson & As.soc:iates 8 ANALYSIS (cont'd) 8.2 High-Frequency Seismic Demand (cont'd) 8.2.2 Vertical Seismic Demand (cont'd)

Calculate the vertical in-structure amplification factor based on the distance between the plant foundation elevation and the subject floor elevation.

Distance Between Component Floor hcomp = 115.QQ .ft and Foundation (See Sect. 8.2.1 of this Calculation):

Work the distance between the component floor and foundation with Ref. 1.1, Fig . 4-4 to calculate the vertical in-structure amplification factor.

2.7 1.0 1 Slope of Amplification Factor Line: mv : ~ - 0.017 *-

1OD ft - Oft ft Intercept of Amplification Factor Line:

Vertical In-Structure Amplification Factor: AF SV :- mv* hcomp + bv = 2.96 Per Ref. 1.1, the vertical in-cabinet amplification factor is 4. 7 regardless of cabinet type.

Vertical In-Cabinet Amplification Factor:

Multiply the peak vertical GMRS acceleration between by the vertical in-structure and in-cabinet amplification factors to determine the in-cabinet response spectrum demand on the component.

Vertical In-Cabinet Response Spectrum (Ref. 1.1, p. 4-12, Eq. 4-1b): ICRSc.v :: AFsv*AFc.v *SAvGMRS = 3.60 *g Note that the vertical seismic demand is the same for both components PIS-050-1 N653 and E51A-K1 DA.

Page 39 of 110

15(4345-RPT-002, Rev. a Correspondence No.: RS-16-177 SA S&A Cale. No.: 15C4345-CAL-001, Rev. 2 Sheet 17 of 20

Title:

High Frequency Functional Confirmation and Prepared : FG Date : 10/27/16 Fragility Evaluation of Components Reviewed: MD Date : 10/27/16 Steven.son & Associates 8 ANALYSIS (cont'd) 8.3 High-Frequency Seismic Capacity A sample calculation for the high-frequency seismic capacity of components PIS-050-1 N653 and E51A-K10 located in Unit 1 is presented here. A table that calculates the high-frequency seismic capacities for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation.

8.3.1 Seismic Test Capacity The high frequency seismic capacity of a component can be determined from the EPRI High Frequency Testing Program (Ref. 1.2) or other broad banded low frequency capacity data such as the Generic Equipment Ruggedness Spectra (GERS) or other qualification reports.

The model for component PIS-050-1 N653, a Rosemount 510DU2 trip unit per Table A-1 , was not tested as part of the Ref. 1.2 high-frequency testing program. Attachment A (Group 1) provides a seismic capacity calculation for Rosemount 510DU2 trip unit based on Limerick Seismic Report GE-101 (Ref. 3.20). The seismic capacity was calculated in Attachment A to be 11. 62g for component Pl S-050-1 N653.

The model for component E51A-K10 is an Agastat EGPB002 relay per Table A-1 . Per Ref. 5.1, Page 2, Agastat EGP and GP series relays are the same relays and the "E" (nuclear safety related) designator was added to the front. Per Ref. 1.12, Page 2-4, the lowest capacity of Agastat Model GP relay 5.0g. Note that the capacity of Agastat GP relay provided in Ref. 1.12, Page 2-4 and 2-6 is based on additional verification test level only (this capacity is not the GERS capacity, but a qualification test capacity).

11.62) PIS-050-1 N653 )

Seismic Test Capacity (SA*): SA':= ( g 5.00 ( E51A-K10 8.3.2 Effective Spectral Test Capacity Since a qualification report was used as the capacity source for both components , there are no spectral acceleration increases and the effective spectral test capacity is equal to the seismic test capacity.

PIS-050-1 N653)

Effective Spectral Test Capacity SAT *-(SA'1

.- J-(11.62)

- *g (

(Ref. 1.1, p. 4-16): SA'2 5.00 E51A-K10 Page 40 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No.: 1SC4345-CAL-001, Rev. 2 Sheet 18 of 20

Title:

High Frequency Functional Confirmation and Prepared: FG Date : 10/27/16 Fragility Evaluation of Components Reviewed: MD Date : 10/27/16 Stevenson & Associates 8 ANALYSIS (cont'd) 8.3 High-Frequency Seismic Capacity (cont'd) 8.3.3 Seismic Capacity Knockdown Factor Determine the seismic capacity knockdown factor for the subject component based on the type of testing used to determine the seismic capacity of the component.

Using Table 4-2 of Ref. 1.1 and the capacity sources from Section 8.3.1 above, the knockdown factors are chosen as :

PIS-050-1 N653)

Seismic Capacity Knockdown Factor: F := (1 .20 )

k 1.20 ( E51A-K10 8.3.4 Seismic Testing Single-Axis Correction Factor Determine the seismic testing single-axis correction factor of the subject component, which is based on whether the equipment housing to which the component is mounted has well-separated horizontal and vertical motion or not.

Per Ref. 1.1, pp. 4-18, conservatively take the FMs value as 1.0.

Single-Axis Correction Factor FMS := 1.0 (Ref. 1.1, pp. 4-17 to 4-18):

Page 41 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 S&A Cale. No. : 15C4345-CAL-001, Rev. 2 Sheet 19 of 20

Title:

High Frequency Functional Confirmation and Prepared : FG Date: 10/27/16 Fragility Evaluation of Components Reviewed: MD Date: 10/27/16 Steven.son & As.scciates 8 ANALYSIS (cont'd) 8.3 High-Frequency Seismic Capacity for Ref. 1.1 Components (cont'd) 8.3.5 Effective Wide-Band Component Capacity Acceleration Calculate the effective wide-band component capacity acceleration per Ref. 1.1, Eq. 4-5.

Effective Wide-Band Component SAT) (9.683) PIS-050-1N653 )

Capacity Acceleration TRS :=- - *FMS = *g

[ Fk ( E51A-K10 (Ref. 1. 1, Eq. 4-5): 4.167 8.4 High-Frequency Seismic Capacity for Ref. 1.4, Appendix H Components 8.4.1 Effective Wide-Band Component Capacity Acceleration Per a review of the capacity generation methodologies of Ref. 1.1 and Ref. 1.4, App. H, Section H.5, the capacity of a Ref. 1.4 component is equal to the Ref. 1.1 effective wide-band component capacity multiplied by a factor accounting for the difference between a 1% probability of failure (C 1 %* Ref. 1.1) and a 10%

probability of failure (C 10 'A,. Ref. 1.4).

Per Ref. 1.4, App. H, Table H.1, use the C 10 % vs . C1 % ratio from the Realistic Lower Bound Case for components .

c10',, vs . c,% ratio c 10 :=- 1.36 Effective wide-band component capacity 13.169) PIS-050-1N653 )

TRS1 4 := TRS*C10 -' ( *g (

acceleration (Ref. 1.4, App. H, Sect. H.5) . 5.667 E51A-K10 Page 42 of 110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 SA S&A Cale. No. : 15C4345-CAL-001, Rev. 2 Sheet 20 of 20

Title:

High Frequency Functional Confirmation and Prepared : FG Date : 10/27/16 Fragility Evaluation of Components Reviewed: MD Date: 10/27/16 Stevenson & Associates 8 ANALYSIS (cont'd) 8.5 Component (Ref. 1.1) High-Frequency Margin Calculate the high-frequency seismic margin for components per Ref. 1.1, Eq. 4-6.

A sample calculation for the high-frequency seismic demand of components PIS-050-1 N653 and E51A-K10 is presented here. A table that calculates the high-frequency seismic margin for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation .

TRS (2.689) > 1.0, O.K. (PIS-050-1N653)

Horizontal seismic margin (Ref. 1.1, Eq. 4-6):

ICRSc.h "' 1.157 > 1.0, O.K. E51A-K10 TRS (2.691) > 1.0, O.K. ( PIS-050-1 N653)

Vertical seismic margin (Ref. 1.1, Eq. 4-6):

ICRSc.v = 1.158 > 1.0, O.K. E51A-K10 Both the horizontal and vertical seismic margins for PIS-050-1 N653 and E51A-K10 are greater than 1.00; indicating that these components are adequate for high frequency seismic spectral ground motion for its Ref.

1.1 functions .

8.6 Component (Ref. 1.4) High-Frequency Margin Calculate the high-frequency seismic margin for Ref. 1.4 components per Ref. 1.1, Eq. 4-6.

A sample calculation for the high-frequency seismic demand of component components PIS-050-1 N653 and E51A-K10 is presented here. A table that calculates the high-frequency seismic margin for all of the subject components listed in Attachment A, Table A-1 of this calculation is provided in Attachment A, Table A-2 of this calculation.

TRS1 *4 = (3 .658) > 1.0, O.K. PIS-050-1 N653 )

Horizontal seismic margin (Ref. 1.1, Eq. 4-6):

ICRSc.h 1.574 > 1.0, O.K. ( E51A-K10 TRS1 .4 (3.660) > 1.0, O.K. PIS-050-1 N653)

Vertical seismic margin (Ref. 1.1, Eq. 4-6):

ICRSc.v = 1.575 > 1.0, O.K. ( E51A-K10 Both the horizontal and vertical seismic margins for PIS-050-1 N653 and E51A-K10 are greater than 1.00; therefore, these components are adequate for high-frequency seismic spectral ground motion for its Ref. 1.4 functions.

Page 43 of 110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 B Components Identified for High Frequency Confirmation Table B-1: Components Identified for High Frequency Confirmation

- .- Component Enclosure Component Evaluation

- Floor No. Unit Building Basis for Evaluation ID Type System Function Manufacturer Model No. ID Type Elev. {ft)

PIS-049-

' Control Core RCIC Steam Pressure Control Control Capacity Qualification Result 1 1 Rosemount 510DU1 10-C617 289 Cap> Dem 1N658A Relay Cooling Indicating Switch Cab. Enclosure Test PIS-049- Control Core RCIC Steam Pressure Control Control Qualification 2 1 Rosemount 710DUOIT 10-C640 289 Cap> Dem 1N658C Relay Cooling Indicating Switch Cab. Enclosure Test PIS-049- Control Core RCIC Steam Pressure Control Control Qualification 3 1 Rosemount 510DU1 10-C617 289 Cap> Dem 1N658E Relay Cooling Indicating Switch Cab. Enclosure Test PIS-049- Control Core RCIC Steam Pressure Control Control Qualification 4 1 Rosemount 510DU1 10-C640 289 Cap> Dem 1N658G Relay Cooling Indicating Switch Cab. Enclosure Test PIS-050- Control Core RCIC Pump Suction Control Control Qualification 5 1 Rosemount 510DU2 10-C617 289 Cap> Dem 1N653 Relay Cooling Header Cab. Enclosure Test PIS-050- Control Core RCIC Turbine Exhaust Control Control Qualification 6 1 Rosemount 510DU1 10-C617 289 Cap> Dem 1N655A Relay Cooling Line Vent Cab. Enclosure Test PIS-050- Control Core RCIC Turbine Exhaust Control Control Qualification 7 1 Rosemount 510DU1 10-C640 289 Cap> Dem 1N655C Relay Cooling Line Vent Cab. Enclosure Test PIS-050- Control Core RCIC Turbine Exhaust Control Control Qualification 8 1 Rosemount 510DU1 10-C617 289 Cap> Dem 1N655E Relay Cooling Line Vent Cab. Enclosure Test PIS-050- Control Core RCIC Turbine Exhaust Control Control Qualification 9 1 Rosemount 510DU1 10-C640 289 Cap>Dem 1N655G Relay Cooling Line Vent Cab. Enclosure Test PIS-050- Control Core RCIC Pump Turbine Control Control Qualification 10 1 Rosemount 510DU2 10-C617 289 Cap> Dem 1N656A Relay Cooling Exhaust Cab. Enclosure Test PIS-050- Control Core RCIC Pump Turbine Control Control Qualification 11 1 Rosemount 510DU2 10-C617 289 Cap> Dem 1N656E Relay Cooling Exhaust Cab. Enclosure Test PIS-049- Control Core RCIC Steam Pressure Control Control Qualification 12 2 Rosemount 510DU1 20-C617 289 Cap> Dem 2N658A Relay Cooling Indicating Switch Cab. Enclosure Test PIS-049- Control Core RCIC Steam Pressure Control Control Qualification 13 2 Rosemount 710DUOIT 20-C640 289 Cap> Dem 2N658C Relay Cooling Indicating Switch Cab. Enclosure Test PIS-049- Control Core RCIC Steam Pressure Control Control Qualification 14 2 Rosemount 510DU1 20-C617 289 Cap> Dem 2N658E Relay Cooling Indicating Switch Cab. Enclosure Test Page 44 of 110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 1~~.t~ ~S~f B~ll~~--,

Component Component Evaluation I Floor No.

110 I ' Type_] I~yste~ J~ctlon ~ [Manufactu~ Model No. Type Elev. (ft)

'Basis for CaDacltv Evaluation Result PIS-049- Control Core RCIC Steam Pressure Control Control Qualification 15 2 Rosemount 710DUOTI 20-C640 289 Cap> Dem 2N658G Relay Cooling Indicating Switch Cab. Enclosure Test PIS-050- Control Core RCIC Pump Suction Control Control Qualification 16 2 Rosemount 710DUOTI 20-C617 289 Cap> Dem 2N653 Relay Cooling Header Cab. Enclosure Test PIS-OSO- Control Core RCIC Turbine Exhaust Control Control Qualification 17 2 Rosemount 510DU1 20-C617 289 Cap> Dem 2N655A Relay Cooling Line Vent Cab. Enclosure Test PIS-050- Control Core RCIC Turbine Exhaust Control Control Qualification 18 2 Rosemount 710DUOTI 20-C640 289 Cap> Dem 2N655C Relay Cooling Line Vent Cab. Enclosure Test PIS-050- Control Core RCIC Turbine Exhaust Control Control Qualification 19 2 Rosemount 710DUOTI 20-C617 289 Cap> Dem 2N655E Relay Cooling Line Vent Cab. Enclosure Test PIS-050- Control Core RCIC Turbine Exhaust Control Control Qualification 20 2 Rosemount 510DU2 20-C640 289 Cap> Dem 2N655G Relay Cooling Line Vent Cab _ Enclosure Test PIS-050- Control Core RCIC Pump Turbine Control Control Qualification 21 2 Rosemount 710DUOTI 20-C617 289 Cap> Dem 2N656A Relay Cooling Exhaust Cab. Enclosure Test PIS-050- Control Core RCIC Pump Turbine Control Control Qualification 22 2 Rosemount 710DUOTI 20-C617 289 Cap> Dem 2N656E Relay Cooling Exhaust Cab. Enclosure Test RCIC Pump Suction Pressure Relay Control Core Control Control Qualification 23 1 E51A-K10 Energize on Pressure Agastat EGPB002 10-C621 289 Cap> Dem Relay Cooling Cab. Enclosure Test On Vacuum Less than Set-point RCIC Relay- Energize on Turbine Control Core Control Control Qualification 24 1 E51A-K11A Diaphragm Exhaust Agastat EGPB002 10-C621 289 Cap> Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-point RCIC Relay - Energize On Turbine Control Core Control Control Qualification 25 1 E51A-K11C Diaphragm Exhaust Agastat EGPB002 10-C640 289 Cap> Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-Point RCIC RELAY-Energize on Turbine Control Core Control Control Qualification 26 1 E51A-K12A Diaphragm Exhaust Agastat EGPB002 10-C621 289 Cap> Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-point Page 45 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation "El[

Component 'Enclosure - Component Evaluation No. ' Unit ID II Type  !! Sys;~] ! ~unction lr Man:itact~ i ModelNo. 1 ID

~

Building] ' Elev.

Floor{ft)J Basis for Capacity Evaluation Result RCIC Relay - Energize on Turbine Control Core Control Control Qualification 27 1 E51A-K12C Diaphragm Exhaust Agastat EGPB002 10-C640 289 Cap> Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-Point RCIC Relay -

Control Core Energizes On Turbine Control Control Qualification 28 1 E51A-K13 Agastat EGPB00 2 10-C621 289 Cap> Dem Relay Cooling Exhaust Pressure Cab . Enclosure Test Above Set-point RCIC Relay -

Control Core Energizes On Turbine Control Control Qualification 29 1 E51A-K14 Agastat EGPB00 2 10-C621 289 Cap> Dem Relay Cooling Exhau st Pressure Cab. Enclosure Test Above Set-Point RCIC Relay -

Control Core Energizes On Steam Control Control Qualification 30 1 E51A-K16A Agastat EGPB002 10-C621 289 Cap> Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-poi nt RCIC Re lay -

Control Core Energizes On Steam Control Control Qualification 31 1 E51A-K16C Agastat EGPB00 2 10-C640 289 Cap> Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-Poi nt RCIC Re lay -

Control Core Energizes On Steam Control Control Qualification 32 1 E51A-K17A Agastat EGPB00 2 10-C621 289 Cap> Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-poi nt RCIC Relay -

Control Core Energizes On Steam Control Control Qualification 33 1 E51A-K17C Agastat EGPB00 2 10-C640 289 Cap>Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-Point Control Core RCIC Turbine Trip Control Control Qualification 34 1 E51A-K28 Agastat EGPD002 10-C621 289 Cap> Dem Relay Cooling Auxiliary Relay Cab. Enclosure Test Page 46 of 110

15C4345-RPT-002, Rev . a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

[~n:J [= ro l [_rvpe :! ~te~J I ~ ~ullding !

I <lomponent Enclosure Component Evaluation No. ,

Function x J~nufact~~r l Model No. ID F.loor l;lev. (ft) Basis for capacity Evaluation Result Steam Leak Detection Relay Control Core (RCIC Isolation Signal Control Control Qualification 35 1 E51A-K30A Agastat EGPD002 10-C621 289 Cap > Dem Relay Cooling Manual Isolation Cab. Enclosure Test Relay - Valve ESl-F008)

RCIC DIV 3 Isolation Control Core Signal and Steam Control Control Qualification 36 1 ES1A-K30C Agastat EGPD002 10-C640 289 Cap > Dem Relay Cooling line Detection Relay Cab. Enclosure Test (ES1-F007)

RCIC Isolation Signal Control Core Manual Isolation Control Control Qualification 37 1 E51A-K31A Agastat EGPD002 10-C621 289 Cap> Dem Relay Cooling Relay - Valve ESl- Cab. Enclosure Test F008 RCIC Isolation Signal Control Core Manual Isolation Control Control Qualification 38 1 ES1A-K31C Agastat EGPD002 10-C640 289 Cap> Dem Relay Cooling Relay- Valve ESl- Cab. Enclosure Test F008 Control Core RCIC DIV 3 Isolation Control Control Qualification 39 1 E51A-K67C Agastat EGPD002 10-C640 289 Cap> Dem Relay Cooling Signal Relay Cab. Enclosure Test RCIC Pump Suction Pressure Relay -

Control Core Control Control Qualification 40 2 ESlA-KlO Energize on Pressure Agastat EGPB003 20-C621 289 Cap > Dem Relay Cooling Cab. Enclosure Test on Vacuum Less than Set-point RCIC Relay - Energize on Turbine Co ntrol Core Control Control Qualification 41 2 ESlA-KllA Diaphragm Exhaust Agastat EGPB003 20-C621 289 Cap > Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-Point RCIC Relay - Energize on Turbine Control Core Control Control Qualification 42 2 ESlA-KllC Diaphragm Exhaust Agast at EGPB003 20-C640 289 Cap > Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-Point Page 47of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Component Evaluation' I - - Floor *1 No. I Unit ID Type System I

Function Manufacturer Model No. ID Type Building I Elev. (ft) Basis for Evaluation

- capacltv Result RCIC Relay - Energize on turbine Control Core Control Con t rol Qualification 43 2 E51A-K12A Diaphragm Exhaust Agastat EGPB003 20-C621 289 Cap> Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-Point RCIC Relay - Energize on Turbine Control Core Control Control Qualification 44 2 E51A-K12C Diaphragm Exhaust Agastat EGPB003 20-C640 289 Cap> Dem Relay Cooling Cab. Enclosure Test Pressure Above Set-Point RCIC Relay-Control Core Energizes on Turbine Control Control Qualification 45 2 E51A-K13 Agastat EGPB003 20-C621 289 Cap> Dem Relay Cooling Exhaust Pressure Cab. Enclosure Test Above Set-Point RCIC Relay-Control Core Energizes on Turbine Control Control Qualification 46 2 E51A-K14 Agastat EGPB003 20-C621 289 Cap >Dem Relay Cooling Exhaust Pressure Cab. Enclosure Test Above Set-Point RCIC RELAY-Control Core Energizes On Steam Control Control Qualification 47 2 E51A-K16A Agastat EGPB003 20-C621 289 Cap> Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-Point RCIC Relay-Control Core Energizes on Steam Control Control Qualification 48 2 E51A-K16C Agastat EGPB003 20-C640 289 Cap> Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-Point RCIC RELAY-Control Core Energizes On Steam Control Control Qualification 49 2 E51A-K17A Agastat EGPB003 20-C621 289 Cap> Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-Point RCIC Relay-Control Core Energizes on Steam Control Control Qualification 50 2 E51A-K17C Agastat EGPB002 20-C640 289 Cap> Dem Relay Cooling Line Pressure Below Cab. Enclosure Test Set-Point Control Core RCIC Turbine Trip Control Control Qualification 51 2 E51A-K28 Agastat EGPD003 20-C621 289 Cap> Dem Relay Cooling Auxiliary Relay Cab. Enclosure Test Page 48 of 11 O

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure ;1 Component Evaluation 1No. Unit -- Bullc!lng Floor Elev. (ft)

Basis for  !;valuation ID f,ype System1 Function Manufacturer Model No. ID Type I Capacity I

Result Steam Leak Detection Relay Control Core {RCIC Isolation Signal Control Control Qualification S2 2 ES1A-K30A Agastat EGPD003 20-C621 2S9 Cap> Dem Relay Cooling Manual Isolation Cab. Enclosure Test Relay- Valve ESl-FOOS)

RCIC DIV 3 Isolation Control Core Signal and Steam Control Control Qualification S3 2 ES1A-K30C Agastat EGPD003 20-C640 2S9 Cap> Dem Relay Cooling Line Detection Relay Cab.

  • Enclosure Test (ES1-F007)

RCIC Isolation Signal Control Core Manual Isolation Control Control Qualification S4 2 ES1A-K31A Agastat EGPD003 20-C621 2S9 Cap> Dem Relay Cooling Relay - Valve ESl- Cab. Enclosure Test FOOS RCIC Isolation Signal Control Core Manual Isolation Control Control Qualification SS 2 ES1A-K31C Agastat EGPD003 20-C640 2S9 Cap> Dem Relay Cooling Relay- Valve ESl- Cab. Enclosure Test FOOS Control Core RCIC DIV 3 Isolation Control Control Qualification S6 2 ES1A-K67C Agastat EGPD003 20-C640 2S9 Cap> Dem Relay Cooling Signal Relay Cab. Enclosure Test RCIC System Steam Control Core ETR14B3B Control Control Qualification S7 1 ESlA-KlSA Flow Above Set-point Agastat 10-C621 2S9 Cap> Dem Relay Cooling C2004002 Cab. Enclosure Test Time Delay Relay RCIC System Steam Control Core ETR14B3B Control Control Qualification SS 1 ESlA-KlSC Flow Above Set-Point Agastat 10-C640 289 Cap> Dem Relay Cooling C2004002 Cab. Enclosure Test Time Delay Relay RCIC System Steam Control Core ETR14B3C Control Control Qua lificat1on S9 2 ESlA-KlSA Flow Above Set-point Agastat 20-C621 289 Cap> Dem Relay Cooling 003 Cab. Enclosure Test Time Delay Relay RCIC System Steam Control Core ETR14B3C Control Control Qualification 60 2 ESlA-KlSC Flow Above Set-Point Agastat 20-C640 289 Cap> Dem Relay Cooling 003 Cab. Enclosure Test Time Delay Relay AC/DC lSO/lSl- Protective Power ESW Pump OAPS48 121AC66KS Switch Control Qualification 61 1 GE Dll-Bus-OS 239 Cap> Dem 11508A Relay Support Overcurrent Phase A A-S gear Enclosure Test Systems Page 49 of 110

15C4345-RPT-002, Rev . 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

- C::omponent Enclosure Component Evaluation Floor No. Unit Bulldlng Basis for Evaluation ID f Type System1 Function Manufacturer M oilelNo. ID Type Elev. (ft)

~

Capacity Result AC/DC lS0/151- Protective Power ESW Pump OAP548 121AC66K8 Switch Control Qualification 62 1 GE D11-8us-08 239 Cap> Dem 115088 Relay Support Overcurrent Phase 8 A-S gear Enclosure Test Systems AC/DC lS0/151- Protective Power ESW Pump OAP548 121AC66K8 Switch Control Qualification 63 1 GE D11-8us-08 239 Cap> Dem 11508C Relay Support Overcurrent Phase C A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power ESW Pump 08PS48 121AC66K8 Switch Control Qualification 64 1 GE D12-8us-08 239 Cap> Dem 11608A Relay Support Overcurrent Phase A A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power ESW Pump 08P548 121AC66K8 Switch Control Qualification 65 1 GE D12-8us-08 239 Cap> Dem 116088 Relay Support Overcurrent Phase 8 A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power ESW Pump 08P548 121AC66K8 Switch Control Qualification 66 1 GE D12-8us-08 239 Cap> Dem 11608C Relay Support Overcurrent Phase C A-S gear Enclosure Test Systems AC/DC lS0/151- Protective Power D224 Load Center 121AC778 Switch Control Qualification 67 2 GE D22-8us-05 239 Cap> Dem 11605A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D224 Load Center 121AC778 Switch Control Qualification 68 2 GE D22-8us-05 239 Cap> Dem 116058 Relay Support Overcurrent Phase 8 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D224 Load Center 121AC778 Switch Control Qualification 69 2 GE D22-8us-05 239 Cap> Dem 11605C Relay Support Overcurrent Phase C 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power ESW Pump OCP548 121AC66K8 Switch Control Qualification 70 2 GE D23-8us-08 239 Cap> Dem 11708A Relay Support Overcurrent Phase A A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power ESW Pump OCP548 121AC66K8 Switch Control Qualification 71 2 GE D23-8us-08 239 Cap> Dem 117088 Relay Support Overcurrent Phase B A-S gear Enclosure Test Systems Page 50of110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.

1 I Unit ID ~ype System r

Component Function Manufacturer Model No. ID Enclosure Type Building I Fk>or I Elev. (ft)

Component Evaluation Basis for Evaluation 1 Capacity Result AC/DC 150/151- Protective Power ESW Pump OCP548 121AC66KB Switch Control Qualification 72 2 GE D23-Bus-08 239 Cap> Dem 11708C Relay Support Overcurrent Phase C A-S gear Enclosure Test Systems AC/DC Protective Power 121CW51A Switch Control Qualification 73 1 132-AG501 Anti-Motoring Relay GE Dll-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems AC/DC Protective Power 121CW51A Switch Control Qualification 74 1 132-BGSOl Anti-Motoring Relay GE D12-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems AC/DC Protective Power 121CW51A Switch Control Qualification 75 1 132-CGSOl Anti-Motoring Relay GE Dl3-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems AC/DC Protective Power 121CW51A Switch Control Qualification 76 1 132-DGSOl Anti-Motoring Relay GE D14-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems AC/DC 187G- Protective Power Dll A Phase 121JD52Al Switch Control Qualification 77 1 GE Dll-Bus-07 239 Cap> Dem AGSOlA Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power Dll B Phase 121JD52A1 Switch Control Qualification 78 1 GE Dll-Bus-07 239 Cap> Dem AG501B Relay Support Differential Relay 1A-S gear Enclosure Test Systems AC/DC 187G- Protective Power Dll C Phase 121JD52A1 Switch Control Qualification 79 1 GE Dll-Bus-07 239 Cap> Dem AG501C Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D12 A Phase 121JD52Al Switch Control Qualification 80 1 GE D12-Bus-07 239 Cap> Dem BGSOlA Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power 012 B Phase 121JD52Al Switch Control Qualification 81 1 GE D12-Bus-07 239 Cap> Dem BG501B Relay Support Differential Relay lA-S gear Enclosure Test Systems Page51 of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component

- Enclosure Component Evaluation I

No. I Unit I Building Floor Basis for Evaluation 110 T,y pe I System II Function Manufacturer Model No. ID Type Elev. (ft)

Capacltv Result I

AC/DC 187G- Protective Power D12 C Phase 121JD52Al Switch Control Qualification 82 1 GE D12-Bus-07 239 Cap> Dem BGSOlC Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D13 A Phase 121JD52A1 Switch Control Qualification 83 1 GE D13-Bus-07 239 Cap> Dem CGSOlA Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D13 B Phase 121JD52A1 Switch Control Qualification 84 1 GE D13-Bus-07 239 Cap> Dem CGSOlB Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D13 C Phase 121JD52Al Switch Control Qualification 85 1 GE D13-Bus-07 239 Cap> Dem CGSOlC Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D14 A Phase 121JD52Al Switch Control Qualification 86 1 GE D14-Bus-07 239 Cap> Dem DGSOlA Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D14 B Phase 121JD52Al Switch Control Qualification 87 1 GE D14-Bus-07 239 Cap> Dem DGSOlB Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D14 C Phase 121JD52Al Switch Control Qualification 88 1 GE D14-Bus-07 239 Cap> Dem DGSOlC Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power 121CWS1A Switch Control Qualification 89 2 132-AGSOl Anti-Motoring Relay GE D21-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems AC/DC Protective Power 121CWS1A Switch Control Qualification 90 2 132-BGSOl Anti-Motoring Relay GE D22-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems AC/DC Protective Power 121CW51A Switch Control Qualification 91 2 132-CGSOl Anti-Motoring Relay GE D23-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems Page 52 of 110

15C4345-RPT-002, Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

- Component Enclosure 1 Component Evaluation Floor No. Unit Building Basis for- Evaluation ID Type System Function ' Manufacturer Model No. ID Type Elev. (ft)

Capacity Result AC/DC Protective Power 121CWS1A Switch Control Qualification 92 2 132-DGSOl Anti-Motoring Relay GE D24-Bus-07 239 Cap> Dem Relay Support 2A-S gear Enclosure Test Systems AC/DC 187G- Protective Power D21 A Phase 121JD52Al Switch Control Qualification 93 2 GE D21-Bus-07 239 Cap>Dem AGSOlA Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power 021 B Phase 121JD52Al Switch Control Qualification 94 2 GE D21-Bus-07 239 Cap> Dem AGSOlB Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D21 C Phase 121JD52Al Switch Control Qualification 95 2 GE D21-Bus-07 239 Cap> Dem AGSOlC Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D22 A Phase 121JD52Al Switch Control Qualification 96 2 GE D22-Bus-07 239 Cap> Dem BGSOlA Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D22 B Phase 121JD52Al Switch Control Qualification 97 2 GE D22-Bus-07 239 Cap> Dem BGSOlB Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D22 C Phase 121JD52Al Switch Control Qualification 98 2 GE D22-Bus-07 239 Cap> Dem BGSOlC Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D23 A Phase 121JD52Al Switch Control Qualification 99 2 GE D23-Bus-07 239 Cap> Dem CGSOlA Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D23 B Phase 121JD52Al Switch Control Qualification 100 2 GE D23-Bus-07 239 Cap> Dem CGSOlB Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D23 C Phase 121JDS2Al Switch Control Qualification 101 2 GE 023-Bus-07 239 Cap> Dem CGSOlC Relay Support Differential Relay lA-S gear Enclosure Test Systems Page 53 of 110

15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Compon_ent Enclosure Component Evaluatlon Floor No. Unit ' I Bulldlng Basis for Evaluatlon ID Type System Function Manufacturer Model No. ID Type Elev. (ft) canadtv Result AC/DC 187G- Protective Power D24 A Phase 121JD52Al Switch Control Qualification 102 2 GE D24-8us-07 239 Cap> Dem DG501A Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D24 8 Phase 121JD52Al Switch Control Qualification 103 2 GE D24-8us-07 239 Cap> Dem DG501B Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 187G- Protective Power D24 C Phase 121JD52Al Switch Control Qualification 104 2 GE D24-8us-07 239 Cap> Dem DG501C Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D114 Load Center 121AC778 Switch Control Qualification 105 1 GE Dll-8us-05 239 Cap> Dem 11505A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D114 Load Center 121AC77B Switch Control Qualification 106 1 GE Dll-8us-05 239 Cap> Dem 115058 Relay Support Overcurrent Phase 8 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D114 Load Center 121AC778 Switch Control Qualification 107 1 GE Dll-8us-05 239 Cap> Dem 11505C Relay Support Overcurrent Phase C 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D124 Load Center 121AC778 Switch Control Qualification 108 1 GE D12-8us-05 239 Cap>Dem 11605A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D124 Load Center 121AC778 Switch Control Qualification 109 1 GE D12-8us-05 239 Cap> Dem 116058 Relay Support Overcurrent Phase 8 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D124 Load Center 121AC778 Switch Control Qualification 110 1 GE D12-8us-05 239 Cap> Dem 11605C Relay Support Overcurrent Phase C 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power Dl34 Load Center 121AC778 Switch Control Qualification 111 1 GE D13-8us-05 239 Cap> Dem 11705A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems Page 54of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure i Co!!Jponent Evaluation No. I ~ Unit

~

- Building 11 Floor Basis for Evaluation ID Type System I Function Manufacturer Model No. ID Type J;lev. (ft)

- - Capacity Result AC/DC 150/151- Protective Power D134 Load Center 121AC77B Switch Control Qualification 112 1 GE D13-Bus-05 239 Cap> Dem 117058 Relay Support Overcurrent Phase B 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D134 Load Center 121AC77B Switch Control Qualification 113 1 GE D13-Bus-05 239 Cap>Dem 11705C Relay Support Overcurrent Phase C 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D144 Load Center 121AC77B Switch Control Qualification 114 1 GE D14-Bus-05 239 Cap> Dem 11805A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D144 Load Center 121AC77B Switch Control Qualification 115 1 GE D14-0us-05 239 Cap> Dem 118050 Relay Support Overcurrent Phase 0 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D144 Load Center 121AC770 Switch Control Qualification 116 1 GE D14-0us-05 239 Cap> Dem 11805C Relay Support Overcurrent Phase C 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D214 Load Center 121AC770 Switch Control Qualification 117 2 GE D21-0us-05 239 Cap> Dem 11505A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D214 Load Center 121AC77B Switch Control Qualification 118 2 GE D21-Bus-05 239 Cap> Dem 115050 Relay Support Overcurrent Phase 0 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D214 Load Center 121AC77B Switch Control Qualification 119 2 GE D21-Bus-05 239 Cap> Dem 11505C Relay Support Overcurrent Phase C 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D234 Load Center 121AC77B Switch Control Qualification 120 2 GE D23-Bus-05 239 Cap> Dem 11705A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D234 Load Center 121AC770 Switch Control Qualification 121 2 GE D23-0us-05 239 Cap> Dem 117058 Relay Support Overcurrent Phase B 812A-S gear Enclosure Test Systems Page 55 of 110

15C4345-RPT-002, Rev.a Correspondence No.: RS- 16-177 Table B-1: Components Identified for High Frequency Confirmation B~dlng I Component Enclosure Component Evaluation Floor No. ! r : n-lt l

~ *~_ 10 H T,ype ' J L ~tem I~ F~nctio'!.. ! IManufa~u~~ : Model No. [~ I? ~ilrv~ l Elev. (ft) Basis for capacity Evaluation Result AC/DC 150/151- Protective Power D234 Load Center 121AC77B Switch Control Qualification 122 2 GE D23-Bus-05 239 Cap> Dem 11705C Relay Support Overcurrent Phase C 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power 0244 Load Center 121AC77B Switch Control Qualification 123 2 GE D24-Bus-05 239 Cap>Dem 11805A Relay Support Overcurrent Phase A 812A-S gear Enclosure Test Systems AC/DC 150/151- Prot ective Power D244 Load Center 121AC77B Switch Control Qualification 124 2 GE D24-Bus-05 239 Cap> Dem 118058 Rela y Support Overcurrent Phase B 812A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power D244 Load Center 121AC77B Switch Control Qualification 125 2 GE D24-Bus-05 239 Cap> Dem 11805C Relay Support Overcurrent Phase C 812A-5 gear Enclosure Test Systems AC/DC 150/151- Protective Power ESW Pump ODP548 12JAC66K8 Switch Control Qualification 126 2 GE D24-Bus-08 239 Cap> Dem 11808A Relay Support Overcurrent Phase A A-S gear Enclosure Test Systems AC/DC 150/151- Protective Power ESW Pump ODP548 121AC66K8 Switch Control Qualification 127 2 GE 024-Bus-08 239 Cap> Dem 118088 Relay Support Overcurrent Phase 8 A-S gear Enclosure Test Systems AC/DC 150/151- Protective Pow er ESW Pump ODP548 121AC66K8 Switch Control Qualification 128 2 GE D24-8us-08 239 Cap> Dem 11808C Relay Support Overcurrent Phase C A-S gear Enclosure Test Systems AC/DC A117 Breaker 702 Protective Power 121AC53A Switch Control Qualification 129 1 151-11702A Bus A Phase GE D13-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC All 7 Breaker 702 Protect ive Power 121AC53A Switch Control Qualification 130 1 151-11702B Bus B Phase GE 013-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC All 7 Breaker 702 Protective Power 121AC53A Switch Control Qualification 131 1 151-11702C Bus C Phase GE D13-Bus-02 239 Cap > Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems Page 56of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

-- Component Enclosure

, Component Evaluation Floor No. Unit BuUdlng Basis for Evaluation ID Type f System Function Manufacturer ModellNo. ID Type Elev. (ft)

.J Caoadtv Result AC/DC A117 Breaker 709 Protectrve Power 12JAC53A Switch Control Qualrfication 132 1 151-11709A Bus A Phase GE D13-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A117 Breaker 709 Protective Power 121AC53A Switch Control Qualification 133 1 151-11709B Bus B Phase GE D13-Bus-09 239 Cap>Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC All 7 Breaker 709 Protective Power 121AC53A Switch Control Qualification 134 1 151-11709C Bus C Phase GE D13-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 135 1 GE Dll-Bus-07 239 Cap> Dem AG501A Relay Support Relay Phase A 802A-5 gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 12JAC53A Switch Control Qualification 136 1 GE Dll-Bus-07 239 Cap> Dem AG501B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Swrtch Control Qualification 137 1 GE Dll-Bus-07 239 Cap> Dem AG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 12JAC53A Switch Control Qualification 138 1 GE D12-Bus-07 239 Cap> Dem BG501A Relay Support Relay Phase A 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 139 1 GE D12-Bus-07 239 Cap> Dem BG501B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 140 1 GE D12-Bus-07 239 Cap> Dem BG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 141 1 GE D13-Bus-07 239 Cap> Dem CG501A Relay Support Relay Phase A 802A-S gear Enclosure Test Systems Page 57 of 110

15C4345- RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation r I l ~lt ll r-Component Component Evaluation No.

ID

~f=- Type *1 1iis~~ ~nctio~ =

l~nufacturer I [ M~~~. ,

Enclosure I~ [

Type_ I [ Building I Floor Elev. (ft}

Basis for Ca pacify Evaluation Result AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 142 1 GE D13-Bus-07 239 Cap> Dem CG501B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 143 1 GE D13-Bus-07 239 Cap> Dem CG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 144 1 GE D14-Bus-07 239 Cap> Dem DG501A Relay Support Relay Phase A 802A-S gear Enclosu re Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 145 1 GE D14-Bus-07 239 Cap> Dem DG501B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC lSl- Protective Pow er Phase Overcurrent 121AC53A Switch Control Qualification 146 1 GE D14-Bus-07 239 Cap> Dem DG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC A115 Breaker 502 Protective Power 121ACS3A Switch Control Qualification 147 1 151-11502A Bus A Phase GE Dll-Bus-02 239 Cap > Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective Pow er 121AC53A Switch Control Qualification 148 1 151-11502B Bus B Phase GE Dll-Bus-02 239 Cap > Dem Relay Support 802A-S gear Enclosu re Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective Pow er 121AC53A Switch Control Qualification 149 1 151-11502C Bus C Phase GE Dll-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective Power 121AC53A Switch Control Qualification 150 1 151-11509A Bus A Phase GE Dll-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Prot ective Pow er 121AC53A Switch Cont rol Qualification 151 1 151-11509B Bus B Phase GE Dll-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosu re Test Overcurrent Relay Systems Page 58of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.

a, ID

![ T,ype Protective

' ~temj AC/DC Power Component Function A115 Breaker 509

[

121AC53A

~

~a~ufacturer IMod.ei~~~o. ]~ ID Enclosure I T~~.J Switch iB~;din~]

Control Floor l;lev. (ft)

Comp()nent Evaluation Basis for Capacity Qualification Evaluation Result 152 1 151-11509C Bus C Phase GE Dll-Bus-09 . 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective Power 121AC53A Switch Control Qualification 153 1 151-11602A Bus A Phase GE D12-Bus-02 239 Cap > Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective Power 121AC53A Switch Control Qualification 154 1 151-11602B Bus B Phase GE D12-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosu re Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective Power 121AC53A Switch Control Qualification 155 1 151-11602C Bus C Phase GE D12-Bus-D2 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective Power 121AC53A Switch Control Qualification 156 1 151-11609A Bus A Phase GE D12-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective Power UIAC53A Switch Control Qualification 157 1 151-11609B Bus B Phase GE D12-Bus-09 239 Cap> Dem Relay Support B02A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective Power 121AC53A Switch Control Qualification 158 1 151-11609C Bus c Phase GE D12-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective Power 121AC53A Switch Control Qualification 159 1 151-11802A Bus A Phase GE D14-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC AllB Breaker 802 Protective Power 121AC53A Switch Control Qualification 160 1 151-11802B Bus B Phase GE D14-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC All8 Breaker 802 Protective Power 121AC5 3A Switch Control Qualification 161 1 151-11802C Bus C Phase GE D14-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems Page 59 of 110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Component Evaluatio_11

-- Floor No. II Unit ' Building Basis for Evaluation ID l

T,ype System ' Function AC/DC Manufacturer Model No. ID Type I Elev. (ft)

Capacity Result A118 Breaker 809 Protective Power 121AC53A Switch Control Qualification 162 1 151-11809A Bus A Phase GE D14-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A118 Breaker 809 Protective Power 121AC53A Switch Control Qualification 163 1 151-11809B Bus B Phase GE D14-Bus-09 239 Cap >Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A118 Breaker 809 Protective Power 121AC53A Switch Control Qualification 164 1 151-11809C Bus C Phase GE D14-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A117 Breaker 702 Protective Power 121AC53A Switch Control Qualification 16S 2 151-11702A Bus A Phase GE D23-Bus-02 239 Cap> Dem Relay Support 802A gear Enclosure Test Overcurrent Relay Systems AC/DC A117 Breaker 702 Protective Power 121AC53A Switch Control Qualification 166 2 1Sl-11702B Bus B Phase GE D23-Bus-02 239 Cap> Dem Relay Support 802A gear Enclosure Test Overcurrent Relay Systems AC/DC A117 Breaker 702 Protective Power 121AC53A Switch Control Qualification 167 2 151-11702C Bus C Phase GE D23-Bus-02 239 Cap> Dem Relay Support 802A gear Enclosure Test Overcurrent Relay Systems AC/DC All 7 Breaker 709 Protective Power 121AC53A Switch Control Qualification 168 2 151-11709A Bus A Phase GE D23-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcu rrent Relay Systems AC/DC A117 Breaker 709 Protective Power 121AC53A Switch Control Qualification 169 2 151-11709B Bus B Phase GE D23-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A117 Breaker 709 Protective Power 121AC53A Switch Control Qualification 170 2 151-11709C Bus C Phase GE D23-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 171 2 GE D21-Bus-07 239 Cap> Dem AG501A Relay Support Relay Phase A 802A-S gear Enclosure Test Systems Page 60of110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component I Enclosure Compo!ll!nt Evaluation Floor No. Unit Building Basis for Evaluation I ID Type System Function Manufacturer Model No. ID Type I Elev. (ft) j Capacity

- Result AC/DC 151- Protective Power Phase Overcurrent 121ACS3A Switch Control Qualification 172 2 GE D21-Bus-07 239 Cap> Dem AG501B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121ACS3A Switch Control Qualification 173 2 GE D21-Bus-07 239 Cap> Dem AG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121ACS3A Switch Control Qualification 174 2 GE D22-Bus-07 239 Cap> Dem BG501A Relay Support Relay Phase A 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 12JACS3A Switch Control Qualification 175 2 GE D22-Bus-07 239 Cap> Dem BG501B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 12JACS3A Switch Control Qualification 176 2 GE D22-Bus-07 239 Cap> Dem BG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 12JACS3A Switch Control Qualification 177 2 GE D23-Bus-07 239 Cap>Dem CG501A Relay Support Relay Phase A 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121ACS3A Switch Control Qualification 178 2 GE D23-Bus-07 239 Cap> Dem CG501B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121ACS3A Switch Control Qualification 179 2 GE D23-Bus-07 239 Cap> Dem CG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121ACS3A Switch Control Qualification 180 2 GE D24-Bus-07 239 Cap> Dem DG501A Relay Support Relay Phase A 802A-S gear Enclosure Test Systems AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 181 2 GE D24-Bus-07 239 Cap> Dem DGS01B Relay Support Relay Phase B 802A-S gear Enclosure Test Systems Page 61 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 1 - - Component Enclosure Component Evaluation Floor No. Unit Building I Basis for I Evaluation ID Type System Function Manufacturer Model No. ID Type Elev. (ft)

Capacltv Result AC/DC 151- Protective Power Phase Overcurrent 121AC53A Switch Control Qualification 182 2 GE D24-Bus-07 239 Cap> Dem DG501C Relay Support Relay Phase C 802A-S gear Enclosure Test Systems AC/DC A115 Breaker 502 Protective Power 121AC53A Switch Control Qualification 183 2 151-11502A Bus A Phase GE D21-Bus-02 239 Cap>Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective Power 121AC53A Switch Control Qualification 184 2 151-11502B Bus B Phase GE D21-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 502 Protective Power 121AC53A Switch Control Qualification 185 2 151-11502C Bus C Phase GE D21-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective Power 121AC53A Switch Control Qualification 186 2 151-11509A Bus A Phase GE D21-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective Power 121AC53A Switch Control Qualification 187 2 1Sl-11509B Bus B Phase GE D21-Bus-09 239 Cap>Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A115 Breaker 509 Protective Power 121AC53A Switch Control Qualification 188 2 151-11509C Bus C Phase GE D21-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective Power 121AC53A Switch Control Qualification 189 2 151-11602A Bus A Phase GE D22-Bus-02 239 Cap >Dem Relay Support 803A gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective Power 121AC53A Switch Control Qualification 190 2 151-11602B Bus B Phase GE D22-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 602 Protective Power 121AC53A Switch Control Qualification 191 2 151-11602C Bus C Phase GE D22-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems Page 62 of 110

15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I Component Enclosure Component Evaluation

- Floor No. Unit I ' Function Building 11 Basis for Evaluation ID Type System Manufacturer Model No. ID ' Type Elev. (ft)

_j (;apacltv Result AC/DC A116 Breaker 609 Protective Power 121AC53A Switch Control Qualification 192 2 151-11609A Bus A Phase GE D22-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective Power 121AC53A Switch Control Qualification 193 2 151-11609B Bus B Phase GE D22-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A116 Breaker 609 Protective Power 121AC53A Switch Control Qualification 194 2 151-11609C Bus C Phase GE D22-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective Power 121AC53A Switch Control Qualification 195 2 151-11802A Bus A Phase GE D24-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective Power 121AC53A Switch Control Qualification 196 2 151-11802B Bus B Phase GE D24-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A118 Breaker 802 Protective Power 121AC53A Switch Control Qualification 197 2 151-11802C Bus C Phase GE D24-Bus-02 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC All8 Breaker 809 Protective Power 121AC53A Switch Control Qualification 198 2 151-11809A Bus A Phase GE D24-Bus-09 239 Cap>Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC A118 Breaker 809 Protective Power 121AC53A Switch Control Qualification 199 2 1Sl-11809B Bus B Phase GE D24-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC All8 Breaker 809 Protective Power 121AC53A Switch Control Qualification 200 2 151-11809C Bus C Phase GE D24-Bus-09 239 Cap> Dem Relay Support 802A-S gear Enclosure Test Overcurrent Relay Systems AC/DC All5 Breaker 502 151N- Protective Power 121AC51A Switch Control Qualification 201 1 Neutral Overcurrent GE Dll-Bus-02 239 Cap> Dem 11502 Relay Support 801A-S gear Enclosure Test Relay Systems Page 63 of 110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

- -** Component *-

- Enclosure Component Evaluation 11 Building Floor j No. [ Unit Elev. {ft) ,

Basis1for Evaluation ID :Type I System I Function Manufacturer Model No. ID Type

___j

~

Capacity Result AC/DC AllS Breaker S09 lSlN- Protective Power 121ACS1A Switch Control Qualification 202 1 Neutral Overcurrent GE Dll-Bus-09 239 Cap> Dem 11S09 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC A116 Breaker 602 lSlN- Protective Power 121AC51A Switch Control Qualification 203 1 Neutral Overcurrent GE D12-Bus-02 239 Cap>Dem 11602 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC A116 Breaker 609 1S1N- Protective Power 121ACS1A Switch Control Qualification 204 1 Neutral Overcurrent GE D12-Bus-09 239 Cap> Dem 11609 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC All 7 Breaker 702 1S1N- Protective Power 121AC51A Switch Control Qualification 20S 1 Neutral Overcurrent GE D13-Bus-02 239 Cap> Dem 11702 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC All 7 Breaker 709 1S1N- Protective Power 121AC51A Switch Control Qualification 206 1 Neutral Overcurrent GE D13-Bus-09 239 Cap >Dem 11709 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC A118 Breaker 802 1S1N- Protective Power 121AC51A Switch Control Qualification 207 1 Neutral Overcurrent GE D14-Bus-02 239 Cap> Dem 11802 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC A118 Breaker 809 1S1N- Protective Power 121AC51A Switch Control Qualification 208 1 Neutral Overcurrent GE D14-Bus-09 239 Cap > Dem 11809 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC AllS Breaker S02 lSlN- Protective Power 121AC51A Switch Control Qualification 209 2 Neutral Overcurrent GE D21-Bus-02 239 Cap> Dem 11S02 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC AllS Breaker S09 lSlN- Protective Power 121ACS1A Switch Control Qualification 210 2 Neutral Overcurrent GE D21-Bus-09 239 Cap> Dem 11S09 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC A116 Breaker 602 1S1N- Protective Power 121ACS1A Switch Control Qualification 211 2 Neutral Overcurrent GE D22-Bus-02 239 Cap> Dem 11602 Relay Support 801A-S gear Enclosure Test Relay Systems Page 64 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Component Evaluation No. Unit - Building Floor Basis for Evaluation I ID Type System Function Manufacturer Model1No. ID Type Elev. (ft)

I - capacity__ Result AC/DC A116 Breaker 609 151N- Protective Power 121AC51A Switch Control Quahficat1on 212 2 Neutral Overcurrent GE D22-Bus-09 239 Cap> Dem 11609 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC All 7 Breaker 702 151N- Protective Power 121AC51A Switch Control Qualification 213 2 Neutral Overcurrent GE D23-Bus-02 239 Cap> Dem 11702 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC All 7 Breaker 709 151N- Protective Power 121AC51A Switch Control Qualification 214 2 Neutral Overcurrent GE D23-Bus-09 239 Cap> Dem 11709 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC A118 Breaker 802 151N- Protective Power 121AC51A Switch Control Qualification 215 2 Neutral Overcurrent GE D24-Bus-02 239 Cap> Dem 11802 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC A118 Breaker 809 151N- Protective Power 121AC51A Switch Control Qualification 216 2 Neutral Overcurrent GE D24-Bus-09 239 Cap> Dem 11809 Relay Support 801A-S gear Enclosure Test Relay Systems AC/DC Control Power A115 Bus Lockout Switch Control Qualification 217 1 186-115A Electroswitch Series 24 Dll-Bus-06 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A115 Bus Lockout Switch Control Qualification 218 1 186-115B Electroswitch Series 24 Dll-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power Al15 Bus Lockout Switch Control Qualification 219 1 186-llSC Electroswitch Series 24 Dll-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power Al16 Bus Lockout Switch Control Qualification 220 1 186-116A Electroswitch Series 24 D12-Bus-06 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A116 Bus Lockout Switch Control Qualification 221 1 186-116B Electroswitch Series 24 D12-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems Page 65 of 11 O

15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation j

BI - Component - -- Enclosure Component Evaluation c Floor No.

~ ~.~ ~! T~ J~vste-"'.J Function  ; f1Manufacture~ 'I Model No. ID Type t uildlng] Elev. (ft) B~sis for caoacJty, Evaluation Result AC/DC Control Power All6 Bus Lockout Switch Control Qualification 222 1 186-116C Electroswitch Series 24 D12-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power All 7 Bus Lockout Switch Control Qualification 223 1 186-117A Electroswitch Series 24 D13-Bus-06 239 Cap>Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power All 7 Bus Lockout Switch Control Qualification 224 1 186-117B Electroswitch Series 24 D13-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power All 7 Bus Lockout Switch Control Qualification 225 1 186-117C Electroswitch Series 24 D13-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Cont rol Power All 8 Bus Lockout Switch Control Qualification 226 1 186-118A Electroswitch Series 24 D14-Bus-06 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power All8 Bus Lockout Switch Control Qualification 227 1 186-118B Electrosw itch Series 24 D14-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Cont rol Power A118 Bus Lockout Switch Control Qualification 228 1 186-118C Electroswitch Series 24 D14-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power Switch Control Qualification 229 1 186-AGSOl Dll Lockout Relay Electroswitch Series 24 Dll-Bus-07 239 Cap> Dem Relay Support gear Enclosure Test Systems AC/DC Control Power Switch Control Qualification 230 1 186-BGSOl D12 Lockout Relay Electroswitch Series 24 D12-Bus-07 239 Cap > Dem Relay Support gear Enclosure Test Systems AC/DC Cont rol Power Switch Control Qualification 231 1 186-CGSOl D13 Lockout Relay Electroswitch Series 24 Dl3-Bus-07 239 Cap> Dem Relay Support gear Enclosure Test Systems Page 66 of 110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure ~Component Evaluation No. I <Unit r ID T.'(111! System Function I' Manufacturer Model No. ID Type Building Floor Elev. (ft) [

Basis 1for Evaluation I Capadtv Result AC/DC Control Power Switch Control Qualification 232 1 186-DGSOl D14 Lockout Relay Electroswitch Series 24 D14-Bus-07 239 Cap> Dem Relay Support gear Enclosure Test Systems AC/DC Control Power A115 Bus Lockout Switch Control Qualification 233 2 186-llSA Electroswitch Series 24 D21-Bus-06 239 Cap>Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A115 Bus Lockout Switch Control Qualification 234 2 186-llSB Electroswitch Series 24 D21-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A115 Bus Lockout Switch Control Qualification 235 2 186-115C Electroswitch Series 24 D21-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A116 Bus Lockout Switch Control Qualification 236 2 186-116A Electroswitch Series 24 D22-Bus-06 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A116 Bus Lockout Switch Control Qualification 237 2 186-116B Electroswitch Series 24 D22-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A116 Bus Lockout Switch Control Qualification 238 2 186-116C Electroswitch Series 24 D22-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power All 7 Bus Lockout Switch Control Qua Jification 239 2 186-117A Electroswitch Series 24 D23-Bus-06 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A117 Bus Lockout Switch Control Qualification 240 2 186-117B Electroswitch Series 24 D23-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power All 7 Bus Lockout Switch Control Qualification 241 2 186-117C Electroswitch Series 24 D23-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems Page 67of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation c

El ~ ~ Bul~dln8]

Component Enclosure * '* J Col!lponent Evaluation Floor No.

[~ ID JI Type ff svste;J~ction K 11 Manufacturer ! Model1No. ID Elev. {ft)

Basis for Cai>acltv Evaluation Result AC/DC Control Power A118 Bus Lockout Switch Control Qualification 242 2 186-118A Electroswitch Series 24 D24-Bus-06 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A118 Bus Lockout Switch Control Qualification 243 2 186-llBB Electroswitch Series 24 D24-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power A118 Bus Lockout Switch Control Qualification 244 2 186-118C Electroswitch Series 24 D24-Bus-09 239 Cap> Dem Relay Support Relay gear Enclosure Test Systems AC/DC Control Power Switch Control Qualification 245 2 186-AGSOl D21 Lockout Relay Electroswitch Series 24 D21-Bus-07 239 Cap> Dem Relay Support gear Enclosure Test Systems AC/DC Control Power Switch Control Qualification 246 2 186-BGSOl D22 Lockout Relay Electroswitch Series 24 D22-Bus-07 239 Cap> Dem Relay Support gear Enclosure Test Systems AC/DC Control Power Switch Control Qualification 247 2 186-CGSOl D23 Lockout Relay Electroswitch Series 24 D23-Bus-07 239 Cap>Dem Relay Support gear Enclosure Test Systems AC/DC Control Power Switch Control Qualification 248 2 186-DGSOl D24 Lockout Relay Electroswitch Series 24 D24-Bus-07 239 Cap> Dem Relay Support gear Enclosure Test Systems AC/DC 150G- Protective Power Dl14 Load Center 12HFC11B Switch Control Qualification 249 1 GE Dll-Bus-05 239 Cap> Dem 11505 Relay Support Ground Fault lA-S gear Enclosu re Test Systems AC/DC 150G- Protective Pow er ESW Pump OAP548 12HFC11B Switch Control Qualification 250 1 GE Dll-Bus-08 239 Cap> Dem 11508 Relay Support Ground Fault lA-S gear Enclosure Test Systems AC/DC 150G- Protective Power D124 Load Center 12HFC11B Switch Control Qualification 251 1 GE D12-Bus-05 239 Cap> Dem 11605 Relay Support Ground Fault lA-S gear Enclosure Test Systems Page 68 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS 177 Table B-1: Components Identified for High Frequency Confirmation

'EJ l ~ L:ry~ ~I No. ; Unit :

1 System Component IFunction~* -:J lMan~~cturer j Model No. ID Enclosure Type r~ullding] Floor Elev. {ft)

Component Evaluation Basis for, Capacltv Evaluation Result AC/DC 150G- Protective Power ESW Pump OBP548 12HFC11B Switch Control Qualification 252 1 GE D12-Bus-08 239 Cap> Dem 11608 Relay Support Ground Fault lA-S gear Enclosure Test Systems AC/DC 150G- Protective Power Dl34 Load Center 12HFC11B Switch Control Qualification 253 1 GE D13-Bus-05 239 Cap> Dem 11705 Relay Support Ground Fault lA gear Enclosure Test Systems AC/DC 150G- Protective Power D144 Load Center 12HFC11B Switch Control Qualification 254 1 GE D14-Bus-05 239 Cap> Dem 11805 Relay Support Ground Fault lA-S gear Enclosu re Test Systems AC/DC 151N- Protective Power Dll Neutral Westinghous 264C899A Switch Control Qualification 255 1 Dll-Bus-07 239 Cap> Dem AG501 Relay Support Overcurrent Relay e 01 gear Enclosure Test Systems AC/DC 151N- Protective Power D12 Neutral westinghous 264C899A Switch Control Qualification 256 1 D12-Bus-07 239 Cap> Dem BGSOl Relay Support Overcurrent Relay e 01 gear Enclosu re Test Systems AC/DC lSlN- Protective Power D13 Neutral Westinghous 264C899A Switch Control Qualification 257 1 D13-Bus-07 239 Cap> Dem CGSOl Relay Support Overcurrent Relay e 01 gear Enclosure Test Systems AC/f?C 151N- Protective Power D14 Neutral Westinghous 264C899A Switch Control Qualification 258 1 D14-Bus-07 239 Cap>Dem DG501 Relay Support Overcurrent Relay e 01 gear Enclosure Test Systems AC/DC Protective Power AllS Bus A Phase 12PVD21B Switch Control Qualification 259 1 187-llSA GE Dll-Bus-06 239 Cap> Dem Relay Support Differentia I Relay lA-S gear Enclosure Test Systems AC/DC Protective Power Al15 Bus B Phase 12PVD21B Switch Control Qualification 260 1 187-1158 GE Dll-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power AllS Bus C Phase 12PVD21B Switch Control Qualification 261 1 187-llSC GE Dll-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems Page 69 of 110

15(4345-RPT-002, Rev. a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I *EnclOsure ----=i Un~I Bulldl~

Component f omponent Evaluation JI Floor I

,No. j t

[ 110 _J[ Type System] ~ction- J; Manufacturer Model No. ID

[~J Elev. (ft) 1 Basis for Caoacltv Evaluation Result AC/DC Protective Power A116 Bus A Phase 12PVD21B Switch Control Qualification 262 1 187-116A GE D12-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power A116 Bus B Phase 12PVD21B Switch Control Qualification 263 1 187-116B GE D12-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power A116 Bus C Phase 12PVD21B Switch Control Qualification 264 1 187-116C GE D12-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power All 7 Bus A Phase 12PVD21B Switch Control Qualification 265 1 187-117A GE Dl3-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power All 7 Bus B Phase 12PVD21B Switch Control Qualification 266 1 187-117B GE D13-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power All 7 Bus C Phase 12PVD21B Switch Control Qualification 267 1 187-117C GE Dl3-Bus-06 239 Cap > Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power Al18 Bus A Phase 12PVD21B Switch Control Qualification 268 1 187-118A GE D14-Bus-06 239 Cap>Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power A118 Bus B Phase 12PVD21B Switch Control Qualification 269 1 187-llSB GE D14-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power A118 Bus C Phase 12PVD21B Switch Control Qualification 270 1 187-llSC GE D14-Bus-06 239 Cap > Dem Relay Support Differential Relay lA-5 gear Enclosure Test Systems AC/DC 150G- Protective Power D214 Load Center 12HFC11B Switch Control Qualification 271 2 GE D21-Bus-OS 239 Cap> Dem 11505 Relay Support Ground Fault lA-S gear Enclosure Test Systems Page 70of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

~

Eli Component Enclosyre  :

Component Evalu;itlon Floor No.

ID

]~-- ;vpe J ISys~~] l!unctlo:~ "] [Manufa~~er ] Model No. ID M Building Elev. (ft) Basis for Capacity Evaluation Result AC/DC 150G- Protective Power D224 Load Center 12HFC11B Switch Control Qualification 272 2 GE D22-Bus-05 239 Cap> Dem 11605 Relay Support Ground Fault lA-S gear Enclosure Test Systems AC/DC 150G- Protective Power D234 Load Center 12HFC11B Switch Control Qualification 273 2 GE D23-Bus-DS 239 Cap > Dem 11705 Relay Support Ground Fault lA-S gear Enclosure Test Systems AC/DC 150G- Protective Power ESW Pump OCPS48 12HFC11B Switch Control Qualification 274 2 GE D23-Bus-08 239 Cap> Dem 11708 Relay Support Ground Fault lA-S gear Enclosure Test Systems AC/DC 150G- Protective Power D244 Load Center 12HFC11B Switch Control Qualification 275 2 GE D24-Bus-DS 239 Cap> Dem 11805 Relay Support Ground Fault 1A-S gear Enclosure Test Systems AC/DC 150G- Protective Power ESW Pump DDPS48 12HFC11B Switch Control Qualification 276 2 GE D24-Bus-08 239 Cap> Dem 11808 Relay Support Ground Fault 1A-S gear Enclosure Test Systems AC/DC 151N- Protective Power D21 Neutral Westinghous 264C899A Switch Control Qualification 277 2 D21-Bus-07 239 Cap> Dem AG501 Relay Support Overcurrent Relay e 01 gear Enclosure Test Systems AC/DC 151N- Protective Power D22 Neutral Westinghous 264C899A Switch Control Qualification 278 2 D22-Bus-07 239 Cap>Dem BG501 Relay Support Overcurrent Relay e 01 gear Enclosure Test Systems AC/DC 151N- Protective Power D23 Neutral westinghous 264C899A Switch Control Qualification 279 2 D23-Bus-07 239 Cap> Dem CGSOl Relay Support Overcurrent Relay e 01 gear Enclosure Test Systems AC/DC 151N- Protective Power D24 Neutral Westinghous 264C899A Switch Control Qualification 280 2 D24-Bus-07 239 Cap> Dem DGS01 Relay Support Overcurrent Relay e 01 gear Enclosure Test Systems AC/DC Protective Power AUS Bus A Phase 12PVD21B Switch Control Qualification 281 2 187-llSA GE D21-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems Page 71 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I I Component Enclosure I Component Evaluation Floor No. Unit Building !Iasis for Evaluation ID II Type System Function Manufacturer Model No. ID Type ' Elev. (ft)

Capacltv Result

~

AC/DC Protective Power AUS Bus B Phase 12PVD21B Switch Control Qualification 282 2 187-llSB GE D21-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power AUS Bus C Phase 12PVD21B Switch Control Qualification 283 2 187-USC GE D21-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power AU6 Bus A Phase 12PVD21B Switch Control Qualification 284 2 187-U6A GE D22-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power A116 Bus B Phase 12PVD21B Switch Control Qualification 285 2 187-116B GE D22-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power Al16 Bus C Phase 12PVD21B Switch Control Qualification 286 2 187-116C GE D22-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power All 7 Bus A Phase 12PVD21B Switch Control Qualification 287 2 187-117A GE D23-Bus-06 239 Cap> Dem Relay Support Differential Relay lA-S gear Enclosure Test Systems AC/DC Protective Power A117 Bus B Phase 12PVD21B Switch Control Qualification 288 2 187 -117B GE D23-Bus-06 239 Cap> Dem Relay Support Differential Relay 1A-S gear Enclosure Test Systems AC/DC Protective Power AU 7 Bus C Phase 12PVD21B Switch Control Qualification 289 2 187-117C GE D23-Bus-06 239 Cap> Dem Relay Support Differential Relay 1A-S gear Enclosure Test Systems AC/DC Protective Power A118 Bus A Phase 12PVD21B Switch Control Qualification 290 2 187-118A GE D24-Bus-06 239 Cap> Dem Relay Support Differential Relay 1A-S gear Enclosure Test Systems AC/DC Protective Power A118 Bus B Phase 12PVD21B Switch Control Qualification 291 2 187-118B GE D24-Bus-06 239 Cap> Dem Relay Support Differential Relay 1A-S gear Enclosure Test Systems Page 72 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 8-1: Components Identified for High Frequency Confirmation Component IEnclosure Component Evaluation

~ I Building J Elev.

Floor

,(~~'] [_ ] rs;~ [ ~unction _=1 [ ~anufa~~rer 1I M~eiNo. 1 ID '

No. :'8 1 (ft)

Basis ,for Evaluation f ype Capacitv Result AC/DC Protective Power A118 Bus C Phase 12PVD21B Switch Control Qualification 292 2 187-118C GE D24-Bus-06 239 Cap> Dem Relay Support Differential Relay l A-S gear Enclosure Test Systems Medium AC/DC Dll-Bus-07 Voltage Power Dll Diesel Generator Switch Control Qualification 293 1 ABB/ITE 5HK 350 D11-Bus-07 239 Cap> Dem (152-11507) Ci rcuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC Dll-Bus-05 Voltage Power D114 LC Transformer Switch Control Qualification 294 1 ABB/ITE 5HK 350 D11-Bus-05 239 Cap> Dem

{152-11505) Circuit Support Circu it Breaker gear Enclosure Test Breaker Systems Medium AC/DC QA Essential Service D11-Bus-08 Voltage Pow er Sw itch Control Qualification 295 1 Water Pump Circuit ABB/ITE 5HK 350 Dll-Bus-08 239 Cap> Dem

{152-11508) Circuit Support gear Enclosure Test Breaker Breaker Systems Medium AC/DC D12-Bus-07 Voltage Power D12 Diesel Generator Switch Control Qualification 296 1 ABB/ITE 5HK 350 D12-Bus-07 239 Cap > Dem

{152-11607) Ci rcuit Support Circuit Breaker gear Enclosure Test Breaker Sy stems Medium AC/DC D12-Bus-05 Voltage Power D124 LC Transformer Sw itch Control Qualification 297 1 ABB/ITE 5HK 350 012-Bus-05 239 Cap> Dem (152-11605) Circuit Support Ci rcuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC OB Essential Service D12-Bus-08 Voltage Power Sw itch Control Qualification 298 1 Water Pump Circuit ABB/ITE 5HK 350 D12-Bus-08 239 Cap> Dem (152-11608) Circuit Support gear Enclosure Test Breaker Breaker Systems Medium AC/DC D13-Bus-07 Voltage Power Dl3 Diesel Generator Switch Control Qualification 299 1 ABB/ITE 5HK 350 013-Bus-07 239 Cap > Dem (152-11707) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Page 73 of 110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Component Evaluation Floor No. Unit Building Basis for Evaluation ID Type System Function 'Manufacturer Model1No. ID Type Elev. (ft) i caoacltv Result Medium AC/DC DB-Bus-OS Voltage Power OB4 LC Transformer Switch Control Qualification 300 1 ABB/ITE 5HK 350 DB-Bus-OS 239 Cap> Dem (152-11705) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D14-Bus-07 Voltage Power D14 Diesel Generator Switch Control Qualification 301 1 ABB/ITE SHK 350 D14-Bus-07 239 Cap> Dem (152-11807) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D14-Bus-05 Voltage Power D144 LC Transformer Switch Control Qualification 302 1 ABB/ITE SHK 350 D14-Bus-OS 239 Cap> Dem (152-11805) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D21-Bus-07 Voltage Power D21 Diesel Generator Switch Control Qualification 303 2 ABB/ITE SHK 350 D21 Bus-07 239 Cap> Dem (152-11507) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D21-Bus-OS Voltage Power D214 LC Transformer Switch Control Qualification 304 2 ABB/ITE SHK 350 D21-Bus-OS 239 Cap> Dem (152-11505) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D22-Bus-07 Voltage Power D22 Diesel Generator Switch Control Qualification 305 2 ABB/ITE SHK 350 D22-Bus-07 239 Cap> Dem (152- 11607) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D22-Bus-OS Voltage Power D224 LC Transformer Switch Control Qualification 306 2 ABB/ITE SHK 350 D22-Bus-OS 239 Cap> Dem (152-11605) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D23-Bus-07 Voltage Power D23 Diesel Generator Switch Control Qualification 307 2 ABB/ITE SHK 350 D23-Bus-07 239 Cap> Dem

{152-11707) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Page 74of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I --- ~mponent Enclosure Component Evaluation

'~ - Floor I No. 1 Unit* j" ID il'ype I

System ~ Function I

Manufacturer Model No. ID Type Building

' Elev. (ft) j Basis for Evaluation

~ . ~ L - Capacity Result Medium AC/DC D23-Bus-05 Voltage Power D234 LC Transformer Switch Control Qualification 308 2 ABB/ITE 5HK 350 D23-Bus-05 239 Cap> Dem (152-11705) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC OC Essential Service D23-Bus-08 Voltage Power Switch Control Qualification 309 2 Water Pump Circuit ABB/ITE 5HK 350 D23-Bus-08 239 Cap> Dem (152-11708) Circuit Support gear Enclosure Test Breaker Breaker Systems Medium AC/DC D24-Bus-07 Voltage Power D24 Diesel Generator Switch Control Qualification 310 2 ABB/ITE 5HK 350 D24-Bus-07 239 Cap> Dem (1S2-11807) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC D24-Bus-05 Voltage Power D244 LC Transformer Switch Control Qualification 311 2 ABB/ITE 5HK 350 D24-Bus-05 239 Cap> Dem (152-11805) Circuit Support Circuit Breaker gear Enclosure Test Breaker Systems Medium AC/DC OD Essential Service D24-Bus-08 Voltage Power Switch Control Qualification 312 2 Water Pump Circuit ABB/ITE 5HK 350 D24-Bus-08 239 Cap> Dem (152-11808) Circuit Support gear Enclosure Test Breaker Breaker Systems AC/DC T2A (1ETB- Control Power ETR14D3B 1ETB- Control Diesel Qualification 313 1 Overcrank Relay Tyco 217 Cap> Dem AG501) Relays Support 004 AG501 Cab. Generator Test Systems AC/DC T2B (1ETB- Control Power ETR14D3B 1ETB- Control Diesel Qualification 314 1 Overcrank Relay Tyco 217 Cap> Dem AG501) Relays Support 004 AG501 Cab. Generator Test Systems AC/DC T2A (1ETB- Control Power ETR14D3B 1ETB- Control Diesel Qualification 315 1 Overcrank Relay Tyco 217 Cap> Dem BG501) Relays Support 004 BG501 Cab. Generator Test Systems AC/DC T2B (lETB- Control Power ETR14D3B lETB- Control Diesel Qualification 316 1 Overcrank Relay Tyco 217 Cap> Dem BG501) Relays Support 004 BG501 Cab. Generator Test Systems Page 75 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

~ ~I Component Enclosure I

Component Evaluation Floor No. I Unit I ID i:vpe System II Function Manufacturer Model No. ID Type Building Elev. (ft) I Basis for Capacltv Evaluation Result AC/DC T2A (lETB- Control Power ETR14D3B lETB- Control Diesel Qualification 317 1 Overcrank Relay Tyco 217 Cap > Dem CGSOl) Relays Support 004 CGSOl Cab. Generator Test Systems AC/DC T2B (lETB- Control Power ETR14D3B lETB- Control Diesel Qualification 318 1 Overcrank Relay Tyco 217 Cap> Dem CGSOl) Relays Support 004 CGSOl Cab. Generator Test Systems AC/DC T2A (lETB- Control Power ETR14D3B lETB- Control Diesel Qualification 319 1 Overcrank Relay Amerace 217 Cap> Dem DGSOl) Relays Support 002 DGSOl Cab. Generator Test Systems AC/DC T2B (lETB- Control Power ETR14D3B lETB- Control Diesel Qualification 320 1 Overcrank Relay Amerace 217 Cap> Dem DGSOl) Relays Support 002 DGSOl Cab. Generator Test Systems AC/DC T2A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 321 2 Overcrank Relay Tyco 217 Cap> Dem AGSOl) Relays Support 004 AGSOl Cab. Generator Test Systems AC/DC T2B (2ETB- Control Power ETR14D3B 2ETB Control Diesel Qualification 322 2 Overcrank Relay Tyco 217 Cap> Dem AGSOl) Relays Support 004 AGSOl Cab. Generator Test Systems AC/DC T2A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 323 2 Overcrank Relay Tyco 217 Cap>Dem BGSOl) Relays Support 004 BGSOl Cab. Generator Test Systems AC/DC T2B (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 324 2 Overcrank Relay Tyco 217 Cap> Dem BGSOl) Relays Support 004 BGSOl Cab. Generator Test Systems AC/DC T2A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 325 2 Overcrank Relay Tyco 217 Cap> Dem CGSOl) Relays Support 004 CGSOl Cab. Generator Test Systems AC/DC T2B (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 326 2 Overcrank Relay Tyco 217 Cap > Dem CGSOl) Relays Support 004 CGSOl Cab. Generator Test Systems Page 76 of 110

1SC4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Component Evaluation No. I'rIUnlt j ID Type System

  • l Function Manufacturer Model No. ID Type BulldJng Floor.-

Elev. {ft)

Basls*for Evaluation

~

- 1

- capacity Result AC/DC T2A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 327 2 Overcrank Relay Amerace 217 Cap> Dem DG501) Relays Support 002 DGS01 Cab. Generator Test Systems AC/DC T2B (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 328 2 Overcrank Relay Amerace 217 Cap> Dem DG501) Relays Support 002 DG501 Cab. Generator Test Systems AC/DC T3A (1ETB- Control Power ETR14D3B lETB- Control Diesel Qualification 329 1 High Speed Relay Tyco 217 Cap> Dem AGSOl) Relays Support 004 AGSOl Cab. Generator Test Systems AC/DC T3A (1ETB- Control Power ETR14D3B lETB- Control Diesel Qualification 330 1 High Speed Relay Tyco 217 Cap> Dem BGSOl) Relays Support 004 BGSOl Cab. Generator Test Systems AC/DC T3A (lETB- Control Power ETR14D3B 1ETB- Control Diesel Qualification 331 1 High Speed Relay Tyco 217 Cap> Dem CGSOl) Relays Support 004 CGSOl Cab. Generator Test Systems AC/DC T3A (lETB- Control Power ETR14D3B lETB- Control Diesel Qualification 332 1 High Speed Relay Amerace 217 Cap> Dem DGSOl) Relays Support 002 DGSOl Cab. Generator Test Systems AC/DC T3A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 333 2 High Speed Relay Tyco 217 Cap> Dem AG501) Relays Support 004 AGSOl Cab. Generator Test Systems AC/DC T3A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 334 2 High Speed Relay Tyco 217 Cap> Dem BG501) Relays Support 004 BGSOl Cab. Generator Test Systems AC/DC T3A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 335 2 High Speed Relay Tyco 217 Cap> Dem CGSOl) Relays Support 004 CGSOl Cab. Generator Test Systems AC/DC T3A (2ETB- Control Power ETR14D3B 2ETB- Control Diesel Qualification 336 2 High Speed Relay Amerace 217 Cap >Dem DGSOl) Relays Support 002 DGSOl Cab. Generator Test Systems Page 77of110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.

J Unit I ~

Component

- - Enclosure Building I Floor I Component Evaluation Basls*for Evaluation I Elev. (ft)

  • ID Type System Function Manufacturer Model No. ID Type

- - Capacity Result AC/DC Control Power Emergency Stop lETB- Control Diesel 337 1 Dll-SE Amerace 7024PE 217 GERS Cap> Dem Relays Support Relay AGSOl Cab. Generator Systems AC/DC Control Power Emergency Stop lETB- Control Diesel 338 1 D12-SE Amerace 7024PE 217 GERS Cap>Dem Relays Support Relay BGSOl Cab. Generator Systems AC/DC Control Power Emergency Stop lETB- Control Diesel 339 1 D13-SE Amerace 7024PE 217 GERS Cap> Dem Relays Support Relay CGSOl Cab. Generator Systems AC/DC Control Power Emergency Stop lETB- Control Diesel 340 1 D14-SE Amerace 7024PE 217 GERS Cap> Dem Relays Support Relay DGSOl Cab. Generator Systems AC/DC Control Power Emergency Stop 2ETB- Control Diesel 341 2 D21-SE Amerace 7024PE 217 GERS Cap> Dem Relays Support Relay AGSOl Cab . Generator Systems AC/DC Control Power Emergency Stop 2ETB- Control Diesel 342 2 D22-SE Amerace 7024PE 217 GERS Cap> Dem Relays Support Relay BGSOl Cab. Generator Systems AC/DC Control Power Emergency Stop 2ETB- Control Diesel 343 2 D23-SE Amerace 7024PE 217 GERS Cap> Dem Relays Support Relay CGSOl Cab. Generator Systems AC/DC Control Power Emergency Stop 2ETB- Control Diesel 344 2 D24-SE Amerace 7024PE 217 GERS Cap> Dem Relays Support Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 345 1 Dll-CPl ITE Jl3P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 346 1 Dll-CP2 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay AGSOl Cab. Generator Systems Page 78of110

15C4345-RPT-002, Rev. 0 Correspondence No. : RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No * .

EJ[ -

ID J[ Type ]'i System AC/DC Component

  • ~nction --=i Illll~~ufacturer Model No. ID Enclosure

~

I Buil~~ni] Flo;o J Elev.~)

Component Evaluation Basis for Capacity Evaluation Result Control Power Jacket Cooling lETB- Control Diesel 347 1 D11-CP3 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 348 1 Dll-CTl ITE J13P3012 217 GERS Cap> Dem Rela ys Support Temperature Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 349 1 Dll-CT2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AG501 Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 350 1 D11-CT3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 351 1 Dll-OPl ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay AG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 352 1 Dll-OP2 ITE Jl3P3012 217 GERS Cap> Dem Relays Support Low Relay AG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 353 1 Dll-OP3 ITE J13P3012 217 GERS Cap>Dem Rela ys Support Low Relay AG501 Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 354 1 Dll-OTl ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AG501 Cab. Generator Systems AC/DC Cont rol Power Lube Oil High lETB- Control Diesel 355 1 Dl1-0T2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AGSOl Cab. Generato r Systems AC/DC Control Pow er Lube Oil High lETB- Control Diesel 356 1 Dl1-0T3 ITE J13P3012 217 GERS Cap> Dem Rela ys Support Temperature Relay AGSOl Cab. Generator Systems Page 79 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. 'i EJ 1* ~~.J [ ~ J[~tem] ~ction Compone!lt

,_] rM~ufact~rer II~od;!No.] rw. '_ IDEnclosure ~ ..

r T~]

I Building j iElev.

Floor J (ft)

Component Evaluation Basis for caoacltv

~ Evaluation Result AC/DC Control Power lETB- Control Diesel 357 1 Dll-SDR Shutd own Relay ITE J13P3012 217 GERS Cap> Dem Relays Support AG501 Cab . Generator Systems AC/DC Control Power lETB- Control Diesel 358 1 Dll-SFR Start Failure Relay ITE J13P3012 217 GERS Cap>Dem Relays Support AGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 359 1 D12-CP1 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay BG501 Cab. Generator Systems AC/DC Control Power Jacket Cool ing lETB- Control Diesel 360 1 D12-CP2 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay BG501 Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 361 1 D12-CP3 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay BG501 Cab. Generator Systems AC/DC Control Power Jacke t Coolant lETB- Control Diesel 362 1 D12-CT1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 363 1 D12-CT2 ITE Jl3P3012 217 GERS Cap> Dem Relays Support Temperature Relay BG501 Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 364 1 D12-CT3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 365 1 D12-0P1 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay BG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 366 1 D12-0P2 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay BG501 Cab. Generator Systems Page 80of110

15C4345-RPT-002, Rev. 0 Correspondence No. : RS- 16-177 Table B-1: Components Identified for High Frequency Confirmation B[

~

~ Elev.

Floo~ '

Component Enclosure Component Evaluation No.

  • ~] Type

~~ ~ction I l

[ Manufacturer [ M:ciel No. j 1 ID 1-1 Building (ft)

Basis for CapacltV '*

Evaluation Result AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 367 1 D12-0P3 ITE J13P3012 217 GERS Cap > Dem Relays Support Low Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 368 1 D12-0Tl ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 369 1 D12-0T2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 370 1 D12-0T3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power lETB- Control Diesel 371 1 D12-SDR Shutdown Relay ITE J13P3012 217 GERS Cap> Dem Relays Support BGSOl Cab. Generator Systems AC/DC Control Power lETB- Control Diesel 372 1 D12-SFR Start Failure Relay ITE J13P3012 217 GERS Cap> Dem Relays Support BGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 373 1 D13-CP1 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 374 1 D13-CP2 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 375 1 D13-CP3 ITE J13P3012 217 GERS Cap > Dem Relays Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 376 1 D13-CT1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems Page 81 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. I 81 ,ID II Ty~

Component

] [Sv~i;m ~ ~ction -*

JrManufacturer 1~No.

~

!* ID Enclosure

~

8Building 1 Floor Elev. (ft)

Component Evaluation Basis for Capacity Evaluation Result AC/DC Control Power Jacket Coolant lETB- Control Diesel 377 1 D13-CT2 ITE J13P3012 217 GERS Cap > Dern Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 378 1 D13-CT3 ITE J13P3012 217 GERS Cap> Dern Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 379 1 D13-0P1 ITE J13P3012 217 GERS Cap> Dern Relays Support Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 380 1 D13-0P2 ITE J13P3012 217 GERS Cap > Dern Relays Support Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 381 1 D13-0P3 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay CGSDl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 382 1 Dl3-0T1 ITE J13P3012 217 GE RS Cap > Dern Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 383 1 Dl3-0T2 ITE J13P3012 217 GERS Cap > Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 384 1 Dl3-0T3 ITE J13P3012 217 GERS Cap > De rn Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power lETB- Control Diesel 385 1 Dl3-SDR Shutdown Relay ITE J13P3012 217 GERS Cap> Dem Relays Support CGSOl Cab. Generator Systems AC/DC Control Power lETB- Control Diesel 386 1 013-SFR Start Fai lure Relay ITE J13P3012 217 GERS Cap> Dem Relays Support CGSOl Cab. Generator Systems Page 82of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

r. I EJ rB~~--1

- - Component Enclosure Component_;valuation Floor No.

[ 10_ Jl _:rv~ J~ Syste~ ~ction ==:JI Manufacturer Mo<!el1No. 10 [ Typ~ Elev. (ft)

Basls*for Capacltv1 Evaluation Result AC/DC Co ntrol Power Jacket Cooling l ETB- Control Diesel 387 1 D14-CP1 ITE J13P3012 217 GERS Cap> Dem Rela ys Support Pressure Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling lETB- Control Diesel 388 1 D14-CP2 ITE Jl3P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay DGSOl Cab. Generator Systems AC/DC Cont rol Power Jacket Cooling lETB- Control Diesel 389 1 D14-CP3 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay DGSOl Cab. Generator Systems AC/ DC Control Power Jacket Coolant lETB- Control Diesel 390 1 D14-CT1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 391 1 D14* CT2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant lETB- Control Diesel 392 1 D14-CT3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 393 1 D14-0P1 ITE J13P3012. 217 GERS Cap>Dem Relays Support Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 394 1 D14-0P2 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure lETB- Control Diesel 395 1 D14-0P3 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Cont rol Diesel 396 1 D14-0T1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems Page 83 of 110

15C4345-RPT-002, Rev. 0 Correspondence No. : RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

. *- Component Enclosure Component Evaluation Floor No. Unit Building Basis for Evaluation ID j -- T.ype System Function Manufacturer Model 'No. ID Type Elev. (ft)

Capacity Result AC/DC Control Power Lube Oil High lETB- Control Diesel 397 1 D14-0T2 ITE J13P3012 217 GERS Cap > Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High lETB- Control Diesel 398 1 D14-0T3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems AC/DC Control Power lETB- Control Diesel 399 1 D14-SDR Shutdown Relay ITE J13P3012 217 GERS Cap> Dem Relays Support DGSOl Cab. Generator Systems AC/DC Control Power lETB- Control Diesel 400 1 D14-SFR Start Failure Relay ITE J13P3012 217 GERS Cap> Dem Relays Support DGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 401 2 D21-CP1 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 402 2 D21-CP2 ITE Jl3P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 403 2 D21-CP3 ITE J13P3012 217 GERS Cap>Dem Relays Support Pressure Low Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 404 2 D21-CT1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 405 2 D21-CT2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 406 2 D21-CT3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AGSOl Cab. Generator Systems Page 84of110

15C4345-RPT-002, Rev. 0 Correspondence No. : RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 81 Component IEnclosure Component Evaluation

- Floor J[ rvi .] I Sys~ ~ction ~ rM~ufacturer ~odel N; i Typ~

No. : Building Basis for Evaluation ID_ 11 ID [ I Elev. (ft)

Capacity Result AC/DC Control Powe r Lube Oil Pressure 2ETB- Control Diesel 407 2 D21-0P1 ITE J13P3012 217 GERS Cap > Dem Relays Support Low Relay AGSOl Cab. Generato r Systems AC/DC Cont rol Pow er Lube Oil Pressure 2ETB- Control Diesel 408 2 D21-0P2 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay AGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 409 2 D21-0P3 ITE J13P3012 217 GERS Cap> Dem Rela ys Support Low Relay AGSOl Cab. Generat or Systems AC/DC Cont rol Pow er Lube Oil High 2ETB- Control Diesel 410 2 D21-0Tl ITE J13 P3012 217 GERS Cap> Dem Rela ys Support Temperature Relay AGSOl Cab. Generato r Systems AC/DC Co ntrol Power Lube Oil High 2ETB- Control Diesel 411 2 D21-0T2 ITE J13P3012 217 GERS Cap> Dem Rel ays Support Temperatu re Relay AGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 412 2 D21-0T3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay AGSOl Cab. Generator Systems AC/DC Cont rol Power 2ETB- Control Diesel 413 2 D21-SDR Shutdown Relay ITE J13P3012 217 GERS Cap> Dem Relays Support AGSOl Cab. Generator Systems AC/DC Cont rol Pow er 2ETB- Control Diesel 414 2 D21-SFR Start Failure Relay ITE J13P3012 217 GERS Cap> Dem Relays Support AGSOl Cab. Generator Systems AC/DC Control Pow er Jacket Cooling 2ETB- Control Diesel 415 2 D22-CP1 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay BGSOl Cab. Generator Systems AC/DC Cont rol Pow er Jacket Cooling 2ETB- Control Diesel 416 2 D22-CP2 ITE J13P3012 217 GERS Cap> Dem Rela ys Support Pressure Low Relay BGSOl Cab. Generato r Systems Page 85of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation 81 Component Enclosure Component Evaluation

! (ivs~iij ~ction J Floor 1' Jl.~- !Y~ Manufa~rer ~ M;!'!'l~J ~]

No. ' OM * ] Building Basis for Evaluation

,10 [ ID Elev. (ft)

Capacity Result AC/DC Control Pow er Jacket Cooling 2ETB- Control Diesel 417 2 D22-CP3 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay BGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 418 2 D22-CT1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 419 2 D22-CT2 ITE J13P3012 217 GERS Cap > Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 420 2 D22-CT3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 421 2 D22-0P1 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 422 2 D22-0P2 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 423 2 D22-0P3 ITE J13P3012 217 GERS Cap> Dem Rela ys Support Low Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 424 2 D22-0T1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 425 2 D22-0T2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 426 2 D22-0T3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay BGSOl Cab. Generat or Systems Page 86 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

- component Enclosure Component Evaluation Floor No. Unit I Building Basis for Evaluation ID Type System Function Manufacturer Model No. ID Type Elev. (ft)

Capacity Result AC/DC Control Power 2ETB- Control Diesel 427 2 D22-SDR Shutdown Relay ITE J13P3012 217 GERS Cap> Dem Relays Support BGSOl Cab. Generator Systems AC/DC Control Power 2ETB- Control Diesel 428 2 D22-SFR Start Failure Relay ITE J13P3012 217 GERS Cap> Dem Relays Support BGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 429 2 D23-CP1 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 430 2 D23-CP2 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 431 2 D23-CP3 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 432 2 D23-CT1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 433 2 D23-CT2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 434 2 D23-CT3 ITE Jl3P3012 217 GERS Cap> Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 435 2 D23-0Pl ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 436 2 D23-0P2 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay CGSOl Cab. Generator Systems Page 87 of 110

15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.

I Unit ID I

Type System Component Function Manufacturer ModeiNo. ID Enclosure Type I BuHding j Floor Elev. {ft)

Component Evaluation

'Basis for Evaluation Capacltv Result AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 437 2 D23-0P3 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 438 2 D23-0Tl ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 439 2 D23-0T2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 440 2 D23-0T3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay CGSOl Cab. Generator Systems AC/DC Control Power 2ETB- Control Diesel 441 2 D23-SDR Shutdown Relay ITE Jl3P3012 217 GERS Cap> Dem Relays Support CGSOl Cab. Generator Systems AC/DC Control Power 2ETB- Control Diesel 442 2 D23-SFR Start Failure Relay ITE J13P3012 217 GERS Cap> Dem Relays Support CGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 443 2 D24-CP1 ITE J13P3012 217 GERS Cap>Dem Relays Support Pressure Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 444 2 D24-CP2 ITE Jl3P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Cooling 2ETB- Control Diesel 445 2 D24-CP3 ITE J13P3012 217 GERS Cap> Dem Relays Support Pressure Low Relay DGSOl Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 446 2 D24-CT1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DGSOl Cab. Generator Systems Page 88 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. II Unit r*

110 TvPe

~ '

System Component Function Manufacturer

  • Model No. ID Enclosure Type Building Floor I Elev. (ft)

I Component Evaluation

!Jaslsfor Evaluation I I Capacity Result AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 447 2 D24-CT2 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DG501 Cab. Generator Systems AC/DC Control Power Jacket Coolant 2ETB- Control Diesel 448 2 D24-CT3 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 449 2 D24-0P1 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay DG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 450 2 D24-0P2 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay DG501 Cab. Generator Systems AC/DC Control Power Lube Oil Pressure 2ETB- Control Diesel 451 2 D24-0P3 ITE J13P3012 217 GERS Cap> Dem Relays Support Low Relay DG501 Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 452 2 D24-0T1 ITE J13P3012 217 GERS Cap> Dem Relays Support Temperature Relay DG501 Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 453 2 D24-0T2 ITE J13P3012 217 GERS Cap>Dem Relays Support Temperature Relay DG501 Cab. Generator Systems AC/DC Control Power Lube Oil High 2ETB- Control Diesel 454 2 D24-0T3 ITE Jl3P3012 217 GERS Cap> Dem Relays Support Temperature Relay DG501 Cab. Generator Systems AC/DC Control Power 2ETB- Control Diesel 455 2 D24-SDR Shutdown Relay ITE Jl3P3012 217 GERS Cap> Dem Relays Support DG501 Cab. Generator Systems AC/DC Control Power 2ETB- Control Diesel 456 2 D24-SFR Start Failure Relay ITE J13P3012 217 GERS Cap> Dem Relays Support DG501 Cab. Generator Systems Page 89of110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure Component Evaluation No. !Jnit - ~

Building Floor Basis for Evaluation ID Type System Function Manufacturer Model No. ID I Type Elev. (ft)

'-- capacltv Result AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 457 1 Dll-EOS Honeywell 1A-G501 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 458 1 DlZ-EOS Honeywell 1B-G501 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 459 1 D13-EOS Honeywell 1C-G501 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 460 1 D14-EOS Honeywell 1D-G501 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 461 2 D21-EOS Honeywell 2A-G501 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 462 2 D22-EOS Honeywell 2B-GS01 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 463 2 D23-EOS Honeywell 2C-G501 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC Process Power Engine Overspeed BZE6- Diesel Diesel 464 2 D24-EOS Honeywell 2D-G501 217 EPRI HF Test Cap> Dem Switch Support Switch 2RN7 Engine Generator Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 465 1 Allen Bradley 837-V3J 1A-G501 217 Cap> Dem llOA-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 466 1 Allen Bradley 837-V3J 1A-G501 217 Cap> Dem 110A-2 Switch Support Temperature Switch Engine Generator Test Systems Page 90of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation r

l_~nl~1 C ~ I Build!~

' Component Enclosure _J Component Evaluation l [.

Floor No.

ID fype l ~Ste~ Function IManufacturer II: Mooel No. ID Elev. (ft)

Basis for Capacity Evaluation Result AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 467 1 Allen Bradley 837-V3J lA-GSOl 217 Cap> Dem llOA-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 468 1 Allen Bradley 837-V3J lA-GSOl 217 Cap> Dem 101A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 469 1 Allen Bradley 837-V3J lA-GSOl 217 Cap> Dem 102A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 470 1 Allen Bradley 837-V3J lA-GSOl 217 Cap> Dem 103A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 471 1 Allen Bradley 837-V3J lB-GSOl 217 Cap> Dem llOB-1 Switch Support Temperature Swit ch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 472 1 Allen Bradley 837-V3J lB-GSOl 217 Cap > Dem llOB-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 473 1 Allen Bradley 837-V3J 10-GSOl 217 Cap>Dem llOB-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 474 1 Allen Bradley 837-V3J lB-GSOl 217 Cap> Dem 101B Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 475 1 Allen Bradley 837-V3J lB-GSOl 217 Cap> Dem 102B Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 476 1 Allen Bradley 837-V3J lB-GSOl 217 Cap> Dem 103B Switch Support Temperature Switch Engine Generator Test Systems Page 91 of 110

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No. 1~. Unit j l - -- ~omponent Enclosure Building Floor Component Evaluation Basis for Evaluation 110 ~ype System Function Manufacturer Model No. ID Type Elev. (ft)

- - Capacity Result AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 477 1 Allen Bradley 837-V3J lC-GSOl 217 Cap> Dem llOC-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 478 1 Allen Bradley 837-V3J lC-GSOl 217 Cap> Dem llOC-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 479 1 Allen Bradley 837-V3J lC-GSOl 217 Cap> Dem llOC-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 480 1 Allen Bradley 837-V3J lC-GSOl 217 Cap> Dem lOlC Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 481 1 Allen Bradley 837-V3J lC-GSOl 217 Cap> Dem 102C Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 482 1 Allen Bradley 837-V3J lC-GSOl 217 Cap> Dem 103C Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 483 1 Allen Bradley 837-V3J lD-GSOl 217 Cap >Dem llOD-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 484 1 Allen Bradley 837-V3J lD-GSOl 217 Cap> Dem llOD-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 485 1 Allen Bradley 837-V3J lD-GSOl 217 Cap> Dem llOD-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 486 1 Allen Bradley 837-V3J lD-GSOl 217 Cap> Dem 101D Switch Support Temperature Switch Engine Generator Test Systems Page 92 of 110

15(4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.

EJ! = ID * - ] I~ T,ype s-, ~~ Fnct~

AC/DC Component 11 Manufacture~ G~el No. 1 I

ID Enclosure

[;~

=i Building al Floor Elev. (ft) I Component Evaluation Basis for Capacity Evaluation Result TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 487 1 Allen Bradley 837-V3J lD-GSOl 217 Cap> Dem 102D Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 488 1 Allen Bradley 837-V3J lD-GSOl 217 Cap> Dem 103D Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 489 2 Allen Bradley 837-V3J 2A-G501 217 Cap> Dem 210A-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 490 2 Allen Bradley 837-V3J 2A-G501 217 Cap> Dem 210A-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 491 2 Allen Bradley 837-V3J 2A-GS01 217 Cap> Dem 210A-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 492 2 Allen Bradley 837-V3J 2A-G501 217 Cap> Dem 201A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 493 2 Allen Bradley 837-V3J 2A-G501 217 Cap>Dem 202A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 494 2 Allen Bradley 837-V3J 2A-G501 217 Cap> Dem 203A Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 495 2 Allen Bradley 837-V3J 2B-G501 217 Cap> Dem 2106-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 496 2 Allen Bradley 837-V3J 2B-G501 217 Cap> Dem 2108-2 Switch Support Temperature Switch Engine Generator Test Systems Page 93 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation No.

j 81 ltl H Component Type~ (~;te~ Enction I rMan~cturer I~ ModeiN~

ID Enclosure Type

,je:i:1ng] Floor Elev. (ftJ Component Evaluation Basis for Capatity Evaluation Result AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 497 2 Allen Bradley 837-V3J 2B-GS01 217 Cap> Dem 210B-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 498 2 Allen Bradley 837-V3J 2B-GS01 217 Cap> Dem 2018 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 499 2 Allen Bradley 837-V3J 2B-GS01 217 Cap> Dem 202B Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification soo 2 203B Switch Temperature Switch Allen Bradley 837-V3J 2B-GS01 Engine Generator 217 Cap>Dem Support Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 501 2 Allen Bradley 837-V3J 2C-G501 217 Cap> Dem 210C-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification S02 2 Allen Bradley 837-V3J 2C-GS01 217 Cap> Dem 210C-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 503 2 Allen Bradley 837-V3J 2C-G501 217 Cap> Dem 210C-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 504 2 Allen Bradley 837-V3J 2C-G501 217 Cap> Dem 201C Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 50S 2 Allen Bradley 837- V3J 2C-GS01 217 Cap> Dem 202C Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 506 2 Allen Bradley 837-V3J 2C-G501 217 Cap> Dem 203C Switch Support Temperature Switch Engine Generator Test Systems Page 94of110

15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation I

~ ~nl~ t= ~~o =J L Tv~~] j B~dl:J

- Component Enclosure -Component Evaluation Floor

~ction _J ; Manufacture~ ID ~I No. Basis for Evaluation Model No. Elev. (ft)

System] Capacltv Result AC/DC TSH-G A- Process Power Jacket Coolant Diesel Diesel Qualification 507 2 Allen Bradley 837-V3J 2D-G501 217 Cap > Dem 210D-1 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 508 2 Allen Bradley 837-V3J 2D-G501 217 Cap > Dem 210D-2 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Jacket Coolant Diesel Diesel Qualification 509 2 Allen Bradley 837-V3J 2D-G501 217 Cap> Dem 210D-3 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 510 2 Allen Bradley 837-V3J 2D-G501 217 Cap> Dem 2010 Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-GA- Process Power Lube Oil High Diesel Diesel Qualification 511 2 Allen Bradley 837-V3J 2D-G501 217 Cap> Dem 202D Switch Support Temperature Switch Engine Generator Test Systems AC/DC TSH-G A- Process Power Lube Oil High Diesel Diesel Qualification 512 2 Allen Bradley 837-V3J 2D-G501 217 Cap> Dem 203D Switch Support Temperature Switch Engine Generator Test Systems Load AC/DC Low Voltage Center D114-33 Power D114-D-G Motor K-600 Reactor Qualification 513 1 (52-20133)

Circuit Support Control Center ABB/ITE Breaker D114-33 I Enclosure 313 Test Cap> Dem Breaker Switch Systems gear Load AC/DC Low Voltage D114-R-G Motor Center D114-32 Power K-600 Reactor Qualification 514 1 (52-20132)

Circuit Support Control Center ABB/ITE Breaker D114-32 I Enclosure 313 Test Cap> Dem Breaker Circuit Breaker Switch Systems gear Load AC/DC Low Voltage Center D124-33 Power D124-D-G Motor K-600 Reactor Qualification 515 1 (52-20233)

Circuit Support Control Center ABB/ITE Breaker D124-33 I Enclosure 313 Test Cap> Dem Breaker Switch Systems gear Page 95 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation

~

Component Enclosure Component Evaluation I - Building j r F.loor No. * . Unit ID Elev. (ft)

Basis for Evaluation

  • 10 Type System Function Manufacturer Model No. Type

..J Capacltv Result Load AC/DC Low Voltage D124-R-G Motor Center D124-32 Power K-600 Reactor Qualification 516 1 Circuit Control Center ABB/ITE Breaker D124-32 I Enclosure 313 Test Cap> Dem (52-20232) Support Breaker Circuit Breaker Switch Systems gear Load AC/DC Low Voltage Center D134-33 Power D134-D-G Motor K-600 Reactor Qualification 517 1 Circuit Control Center ABB/ITE Breaker D134-33 I Enclosure 253 Test Cap> Dem (52-20333) Support Breaker Switch Systems gear Load AC/DC Low Voltage D134-R-E Motor Center D134-24 Power K-600 Reactor Qualification 518 1 Circuit Control Center ABB/ITE Breaker D134-24 I Enclosure 253 Test Cap> Dem (52-20324) Support Breaker Circuit Breaker Switch Systems gear Load AC/DC Low Voltage Center D144-33 Power D144-D-G Motor K-600 Reactor Qualification 519 1 Circuit Control Center ABB/ITE Breaker D144-33 I Enclosure 283 Test Cap> Dem (52-20433) Support Breaker Switch Systems gear Load AC/DC Low Voltage D144-R-E Motor Center D144-24 Power K-600 Reactor Qualification 520 1 Circuit Control Center ABB/ITE Breaker D144 -24 I Enclosure 283 Test Cap> Dem (S2-20424) Support Breaker Circuit Breaker Switch Systems gear Load AC/DC Low Voltage Center D214-33 Power D214-D-G Motor K-600 Reactor Qualification 521 2 Circuit Control Center ABB/ITE Breaker D214-33 I Enclosure 313 Test Cap> Dem (52-20133) Support Breaker Switch Systems gear Load AC/DC Low Voltage D214-R-G Motor Center 0214-32 Power K-600 Reactor Qualification 522 2 Circuit Control Center ABB/ITE Breaker D214-32 I Enclosure 313 Test Cap> Dem

{52-20132) Support Breaker Circuit Breaker Switch Systems gear Load AC/DC Low Voltage Center D224-33 Power 0224-D-G Motor K-600 Reactor Qualification 523 2 Circuit Support Control Center ABB/ITE Breaker D224-33 I Enclosure 313 Test Cap> Dem

{52-20233)

Breaker Switch Systems gear Page 96 of 11 O

1SC4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-1: Components Identified for High Frequency Confirmation Component Enclosure I- Component Evaluation

~ Floor INo. 1 Unit

[ I 110 .~J LTv~-=_] Sys~e~J [_FUnction ..

~ ~anufacturer I~ N~ ID [ iype ]

Building Elev. {ft)

Basis for caoacitV Evaluation Result Load AC/DC Low Voltage D224-R-G Motor Center D224-32 Power K-600 Reactor Qualification 524 2

{52-20232)

Circuit Support Control Center ABB/ITE Breaker D224-32 I Enclosure 313 Test Cap> Dem Breaker Circuit Breaker Switch Systems gear Load AC/DC Low Voltage Center D234-33 Power D234-D-G Motor K-600 Reactor Qualification 525 2 (52-20333)

Circuit Support Control Center ABB/ITE Breaker D234-33 I Enclosure 253 Test Cap> Dem Breaker Switch Systems gear Load AC/DC Low Voltage D234-R-E Motor Center D234-24 Power K-600 Reactor Qualification 526 2

{52-20324)

Circuit Support Control Center ABB/ITE Breaker D234-24 I Enclosure 253 Test Cap> Dem Breaker Circuit Breaker Switch Systems gear Load AC/DC Low Voltage Center D244-33 Power D244-D-G Motor K-600 Reactor Qualification 527 2 (52-20433)

Circuit Support Control Center ABB/ITE Breaker D244-33 I Enclosure 283 Test Cap> Dem Breaker Switch Systems gear Load AC/DC Low Voltage D244-R-E Motor Center D244-24 Power K-600 Reactor Qualification 528 2

{52-20424)

Circuit Support Control Center ABB/ITE Breaker D244-24 I Enclosure 283 Test Cap> Dem Breaker Circu it Breaker Switch Systems gear Page 97 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I -

VAi.VE Ill> (Qn *' I PIMSID. I P&ID f .SHEET Notes I Evaluated in Ref. [1:8]

P&ID HV-lFOOl HV-041-lFOOl M-0041 1 Yes*

HV-1F002 HV-041-1F002 M-0041 1 Yes*

NORMALLY OPEN TO MAIN STEAM LINE C. NOT A LEAK PATH HV-lFOOS HV-041-lFOOS M-0041 1 No (No Need to be included- Line C is isolated)

DOWN STREAM CHECK VALVE HV-HV-lFOllA HV-041-lFOllA M-0041 1 lFOlOA will provide Boundary (No No Need to be included)

SIMPLE CHECK VALVE (No Need to lFOlOA 041-lFOlOA M-0041 1 No be included)

DOWN STREAM OF CHECK VALVE HV-1F074A HV-041-1F074A M-0041 1 No (No Need to be included)

DOWN STREAM CHECK VALVE HV-HV-lFOllB HV-041-lFOllB M-0041 1 lFOlOB will provide Boundary (No No Need to be included)

SIMPLE CHECK VALVE (No Need to lFOlOB 041-lFOlOB M-0041 1 No be included)

DOWN STREAM OF CHECK VALVE HV-1F074B HV-041-1F074B M-0041 1 No (No Need to be included)

PSV-1F013A PSV-041-1F013A M-0041 2 SRV Yes*

Page 98of110

15C4345-RPT-002, Rev. a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE Ill> on i' I PIMSID P&ID SHEET Notes Evaluated in Ref., [18)

P&ID PSV-1F013B PSV-041-1F013B M-0041 2 SRV Yes*

PSV-1F013C PSV-041-1F013C M-0041 2 SRV Yes*

PSV-1F013D PSV-041-1F013D M-0041 2 SRV Yes*

PSV-1F013E PSV-041-1F013E M-0041 2 SRV Yes*

PSV-1F013F PSV-041-1F013F M-0041 2 SRV Yes*

PSV-1F013G PSV-041-1F013G M-0041 2 SRV Yes*

PSV-1F013H PSV-041-1F013H M-0041 2 SRV Yes*

PSV-1F013J PSV-041-1F013J M-0041 2 SRV Yes*

PSV-1F013K PSV-041-1F013K M-0041 2 SRV Yes*

PSV-1F013L PSV-041-1F013L M-0041 2 SRV Yes*

PSV-041-PSV-1F013M M-0041 2 SRV Yes*

1F013M PSV-1F013S PSV-041-1F013S M-0041 2 SRV Yes*

PSV-1F013N PSV-041-1F013N M-0041 2 SRV Yes*

HV-F022A HV-041-1F022A M-0041 2 Yes*

HV-F028A HV-041-1F028A M-0041 2 Yes*

HV-F022B HV-041-1F022B M-0041 2 Yes*

Page 99of110

15C4345-RPT-002,Rev.O Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation V~LVE ID on IP&ID

[ PIMS l D J P&ID rH~~T I l Notes l Evaluated in Ref. [18]

HV-F028B HV-041-1F028B M-0041 2 Yes*

HV-F022C HV-041-1F022C M-0041 2 Yes*

HV-F028C HV-041-1F028C M-0041 2 Yes*

HV-F022D HV-041-1F022D M-0041 2 Yes*

HV-F028D HV-041-1F028D M-0041 2 Yes*

HV-C-F020 HV-C-041-1F020 M-0041 2 Yes*

HV-1F016 HV-041-lFOlG M-0041 2 Normally Closed Drain Line Yes*

Normally Closed Drain Line would No - See notes and discussion in HV-1F019 HV-041-1F019 M-0041 2 only be a Leak Path if HV-1F016 Section 2.2 of this report.

Opens Normally Open- Need to check if HV-lFlOS HV-044-lFlDS M-0044 1 Yes*

there is a signal to close Would only be a Leak Path if HV- No - See notes and discussion in HV-lFOOl HV-044-lFOOl M-0044 1 lFlOS fails to be closed Section 2.2 of this report.

Would only be a Leak Path if HV- No - See notes and discussion in HV-1F004 HV-044-1F004 M-0044 1 lFlOS fails to be closed Section 2.2 of this report.

Normally Open- Need to check if HV-lFlOO HV-044-lFlOO M-0044 1 Yes*

there is a signal to close Page 100of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation

~~ l ;HE~

[~

VAl!.VE ID on P&ID HV-1F007 I

PIMS ID HV-049-1F007 M-0049

___J 1

Notes Normally Open- Need to check if there is a signal to close l' Evaluated in Ref. (18]

Yes*

Would only be a Leak Path if HV- No - See notes and discussion in HV-1F008 HV-049-lFOOS M-0049 1 1F107 fails to be closed Section 2.2 of this report.

Per the Plant this is the Containment Spray Valves and HV-1F021A HV-051-1F021A M-0051 1 No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-1F016A HV-051-1F016A M-0051 1 No - See Note does not communicate with the Reactor HV-1F041C HV-051-1F041C M-0051 1 CHECK VALVE Yes*

No - See notes and discussion in HV-1F017C HV-051-1F017C M-0051 1 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-1F041A HV-051-1F041A M-0051 1 CHECK VALVE Yes*

No - See notes and discussion in HV-1F017A HV-051-1F017A M-0051 1 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-1F050A HV-051-1F050A M-0051 1 CHECK VALVE Yes*

No - See notes and discussion in HV-1F015A HV-051-1F015A M-0051 1 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

Page 101 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE ID on PIMSID P&ID I SHEET Notes I Evaluated in 1Ref. [18)

P&ID HV-1F008 HV-051-lFOOB M-0051 1 Yes*

Per the Plant this is the Containment Spray Valves and HV-1F021B HV-M51-1F021B M-0051 3 No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-1F016B HV-051-1F016B M-0051 3 No - See Note does not communicate with the Reactor HV-1F041D HV-051-1F041D M-0051 3 CHECK VALVE Yes*

No - See notes and discussion in HV-1F017D HV-051-1F017D M-0051 3 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-1F041B HV-051-1F041B M-0051 3 CHECK VALVE Yes No - See notes and discussion in HV-1F017B HV-051-1F017B M-0051 3 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-1F050B HV-051-1F050B M-0051 3 CHECK VALVE Yes*

No - See notes and discussion in HV-1F015B HV-051-1F015B M-0051 3 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-1F009 HV-051-1F009 M-0051 3 Yes*

HV-1F006B HV-052-lFOOGB M-0052 1 CHECK VALVE Yes*

Page 102 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation PIMSID~ 1 P&ID l-~-

[ ~:1 VAl.\VE ID on !

Note; . -,. Evaluated in1Ref. ~18)

P&ID DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-108 HV-052-108 M-0052 1 Only needed if HV-1F006B fails to Section 2.2 of this report.

be closed HV-1F006A HV-052-lFOOGA M-0052 1 CHECK VALVE Yes*

DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-1F005 HV-052-1F005 M-0052 1 Only needed if HV-1F006A fails to Section 2.2 of this report.

be closed Normally Open- Need to check if HV-1F002 HV-055-1F002 M-0055 1 Yes*

there is a signal to close Would only be a potential Leak No - See notes and discussion in HV-1F003 HV-055-1F003 M-0055 1 Path if HV-1F002 fails to be closed Section 2.2 of this report.

HV-2F001 HV-041-2F001 M-0041 4 Yes*

HV-2F002 HV-041-2F002 M-0041 4 Yes*

NORMALLY OPEN TO MAIN STEAM LINE C. NOT A LEAK PATH HV-2F005 HV-041-2F005 M-0041 4 No (No Need to be included- Line C is isolated)

Page 103 of 11 O

1SC4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE 10., on, I

PIMS ID P&ID SHEET  : Notes I Evaluated in Ref. [18)

P&ID I DOWN STREAM CHECK VALVE HV-HV-2F011A HV-041-2F011A M-0041 4 2F010A will provide Boundary (No No Need to be included)

SIMPLE CHECK VALVE {No Need to 2F010A 041-2F010A M-0041 4 No be included)

DOWN STREAM OF CHECK VALVE HV-2F074A HV-041-2F074A M-0041 4 No (No Need to be included)

DOWN STREAM CHECK VALVE HV-HV-2F011B HV-041-2F011B M-0041 4 2F010B will provide Boundary (No No Need to be included)

SIMPLE CHECK VALVE (No Need to 2F010B 041-2F010B M-0041 4 No be included)

DOWN STREAM OF CHECK VALVE HV-2F074B HV-041-2F074B M-0041 4 No (No Need to be included)

PSV-2F013A PSV-041-2F013A M-0041 5 SRV Yes*

PSV-2F013B PSV-041-2F013 B M-0041 5 SRV Yes*

PSV-2F013C PSV-041-2F013C M-0041 5 SRV Yes*

Page 104of110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177

[

Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I s.;~~J -~= l VAL\lE IDmi!

  • I
  • PIMS[ P&ID Notes Evaluated in Ref. r[l8]

P&ID

-~

PSV-2F013D PSV-041-2F013D M-0041 5 SRV Yes*

PSV-2F013E PSV-041-2F013E M-0041 5 SRV Yes*

PSV-2F013F PSV-041-2F013F M-0041 5 SRV Yes*

PSV-2F013G PSV-041-2F013G M-0041 5 SRV Yes*

PSV-2F013H PSV-041-2F013H M-0041 5 SRV Yes*

PSV-2F013J PSV-041-2F013J M-0041 5 SRV Yes*

PSV-2F013K PSV-041-2F013K M-0041 5 SRV Yes*

PSV-2F013L PSV-041-2F013L M-0041 5 SRV Yes*

PSV-041-PSV-2F013M M-0041 5 SRV Yes*

2F013M PSV-2F0135 PSV-041-2F0135 M-0041 5 SRV Yes*

PSV-2F013N PSV-041-2F013N M-0041 5 SRV Yes*

HV-F022A HV-041-2F022A M-0041 5 Yes*

Page 105of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 VA~VE Iii> on P&ID r Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation 0

PIMS ;D~ ] P&ID I SHEET [

I -,=---~-:~** 1 Evaluated in Ref. 1[l8]

HV-F028A HV-041-2F028A M-0041 5 Yes*

HV-F022B HV-041-2F022B M-0041 5 Yes*

HV-F028B HV-041-2F028B M-0041 5 Yes*

HV-F022C HV-041-2F022C M-0041 5 Yes*

HV-F028C HV-041-2F028C M-0041 5 Yes*

HV-F022D HV-041-2F022D M-0041 5 Yes*

HV-F028D HV-041-2F028D M-0041 5 Yes*

HV-C-F020 HV-C-041-2F020 M-0041 5 Yes*

HV-2F016 HV-041-2F016 M-0041 5 Normally Closed Drain Line Yes*

Normally Closed Drain Line would No - See notes and discussion in HV-2F019 HV-041-2F019 M-0041 5 only be a Leak Path if HV-2F016 Section 2.2 of this report.

Opens Normally Open- Need to check if HV-2F105 HV-044-2F105 M-0044 3 Yes*

there is a signal to close Page 106 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table 8-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation 1

VALVJ ID on I I PIMSID P&ID SHEET Notes Evaluated in Ref. 1[1.8]

P&ID I

Would only be a Leak Path if HV- No - See notes and discussion in HV-2F001 HV-044-2F001 M-0044 3 2F105 fails to be closed Section 2.2 of this report.

Would only be a Leak Path if HV- No - See notes and discussion in HV-2F004 HV-044-2F004 M-0044 3 2F105 fails to be closed Section 2.2 of this report.

Normally Open- Need to check if HV-2F100 HV-044-2F100 M-0044 3 Yes*

there is a signal to close Normally Open- Need to check if HV-2F007 HV-049-2F007 M-0049 2 Yes*

there is a signal to close Would only be a Leak Path if HV- No - See notes and discussion in HV-2F008 HV-049-2F008 M-0049 2 2F107 fails to be closed Section 2.2 of this report.

Per the Plant this is the Containment Spray Valves and HV-2F021A HV-051-2F021A M-0051 5 No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-2F016A HV-051-2F016A M-0051 5 No - See Note does not communicate with the Reactor HV-2F041C HV-051-2F041C M-0051 5 CHECK VALVE Yes*

Page 107of110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE ID on 1 PIMSW) P&ID SHEET Notes Evaluated in Ref. [18]

P&ID I

No - See notes and discussion in HV-2F017C HV-051-2F017C M-0051 5 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-2F041A HV-051-2F041A M-0051 5 CHECK VALVE Yes*

No - See notes and discussion in HV-2F017A HV-051-2F017A M-0051 5 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-2F050A HV-051-2F050A M-0051 5 CHECK VALVE Yes*

No - See notes and discussion in HV-2F015A HV-051-2F015A M-0051 5 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-2F008 HV-051-2F008 M-0051 5 Yes*

Per the Plant this is the Containment Spray Valves and HV-2F021B HV-M51-2F021B M-0051 7 No - See Note does not communicate with the Reactor Per the Plant this is the Containment Spray Valves and HV-2F016B HV-051-2F016B M-0051 7 No - See Note does not communicate with the Reactor HV-2F041D HV-051-2F041D M-0051 7 CHECK VALVE Yes*

Page 108 of 110

15C4345-RPT-002, Rev. 0 Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation I - -* I VALVE ID on PIMSID 1

P&ID SHEET Notes Evaluated in Ref. [18]

P&ID JI I

- ~

No - See notes and discussion in HV-2F017D HV-051-2F017D M-0051 7 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-2F041B HV-051-2F041B M-0051 7 CHECK VALVE Yes*

No - See notes and discussion in HV-2F017B HV-051-2F017B M-0051 7 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-2F050B HV-051-2F050B M-0051 7 CHECK VALVE Yes*

No - See notes and discussion in HV-2F015B HV-051-2F015B M-0051 7 DOWN STREAM OF CHECK VALVE Section 2.2 of this report.

HV-2F009 HV-051-2F009 M-0051 7 Yes*

HV-2F006B HV-052-2F006B M-0052 3 CHECK VALVE Yes*

DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-208 HV-052-208 M-0052 3 Only needed if HV-2F006B fails to Section 2.2 of this report.

be closed HV-2F006A HV-052-2F006A M-0052 3 CHECK VALVE Yes*

DOWN STREAM OF CHECK VALVE No - See notes and discussion in HV-2F005 HV-052-2F005 M-0052 3 Only needed if HV-2F006A fails to Section 2.2 of this report.

be closed Page 109of110

15C4345-RPT-002, Rev.a Correspondence No.: RS-16-177 Table B-2: Reactor Coolant Leak Path Valve Identified for High Frequency Confirmation VALVE ID on PIMSID P&ID I, SHEET Notes Evaluated in Ref. [18)

P&ID Normally Open- Need to check if HV-2F002 HV-055-2F002 M-0055 2 Yes*

there is a signal to close Would only be a potential Leak No - See notes and discussion in HV-2F003 HV-055-2F003 M-0055 2 Path if HV-2F002 fails to be closed Section 2.2 of this report.

  • Note: the evaluation of this valve is discussed in Section 2.2 of this report as well as in report 15C4344-RPT-001 (Ref. 18).

Page 11 O of 11 O