ML17037B895

From kanterella
Jump to navigation Jump to search
Letter Regarding Amendment 2, Supplement 1 (August 1977) to Mark II Containment Dynamic Forcing Functions Information Report (Dffr), NEDO-21061, Rev. 2
ML17037B895
Person / Time
Site: Nine Mile Point, Columbia, Limerick, LaSalle, Shoreham, Bailly  File:Long Island Lighting Company icon.png
Issue date: 09/15/1977
From: Sobon L
General Electric Co
To: Parr O
Office of Nuclear Reactor Regulation
References
Download: ML17037B895 (6)


Text

0 STANDARD DISTRIBUTION FOR

%COMING IiAT-RLQ RELATING TO MARK XI CONTAIaÃIENT NRC FOAM-195

("-ill)

UAe NUCI SAA RSQV LATOAVCOMMISSION COOLEST NUMSSA Y/o TO:

Mr. Oman De Parr FROM:

General Electric Company San Jose, California Le Je Sobon NRC DISTRIBUTION FoR PART 50 DOCKET MATERIAL

~AiT&3iÃK TOP ICAL REPORT OATS OF OOCUMSNT 9/ l5/77 OATS RSCSIVSO 9/26/77 RLETTS R RQRIOINAI QCOPV OSSCRIPTION GNOTORIZSO rBVNCLASSIPISD PROP INPUT PORM SNCI OSUAS NUMSS R Ol COPISS RSCSIV SO Z~r LE~rS OF INCORPORATION WILL BE PLACED IN EACH DOCKET LISTED BELOWe NOTE CYS WILL BE PLACED XN THE LPDR FOR THE FOLZDW+G:

ZXMMER NIiVr. MILE POINT 50-410 LIMERX

$0-3 53 WPPS 2

- 97 BAILLY 50-367 SHOREHAM

~ $0<<3%.

(2-P)

LA SALLE 50-373/374 RJL 9/26/77 (l/4")

70 mW ~

z&No.

4'mendment 2, Supplement 1 of the

DFFR, NED0-21061, covering the responses to the forty<<five "Round 2" NRC staff questions on the DFFR and its supporting documentse

~ ~

("Mark XI Containment Dynamic Forcing Functions Information Report" )

h FOR ACTION/INFQ RMATION NTRAL PILES 2

W 9 I NR s

Fo ea STR I BUTION LETTER ONLY Re OEYOUNG tS 7

S ot A

NSIC De-VASSALLO Ke KNIEL Oe PARR ACRS 6

I Ie SIKvELL 2

Ge LAMIAS 7

J IQUGHT 2

C ANDERSON Xe PELTXER Re BXRKEL LYialCH MD Je SNELL Ae BGURNXA We KAiK S ~ MZiER

~

0 Re T DESCO Me RUSHBROOK We PIKE Se VARGA EXTERNALOISTRIBUTION CONTROL NUMBER

GENERAL;'LECTRiC NUCLEAR ENERGY GENERAL ELECTRIC COMPANY, 175 CURTNER AVE., SAN JOSE, CALIFORNIA95125 MC.681 (408) 925-3495 SYSTEMS DIVISION BWR PROJECTS DEPARTMENT September 15, 1977 MFN-354-77 U. S. Nuclear Regulatory Commission Director of Nuclear Reactor Regulation Washington, O.

C. 20555 Attention: 'r. Olan O. Parr, Chief Light Water Reactors Branch No.

3 Division of Reactor Licensing Gentlemen:

SUBJECT:

AMENDMENT 2, SUPPLEMENT 1

(AUGUST 1977)

TO MARK II.

CONTAINMENT DYNAMIC. FORCING FUNCTIONS INFORMATION REPORT (DFFR),. NED0-21061, REV.

2

References:

1.

Letter with enclosur

, "Mark II Containment

-- Request for Additional Infor.,ation," to N.

W. Curtis, (Pennsylvania Power h Light Company),

from 0.

O. ;"arr (NRC), dated January 14, 1977.

2.

Letter with report, "Mark II Containment Dynamic Forcing Functions Information Report (OFFR),

NEDO/

NEDE-21061

)Revision '2,. September 1976j," to R.

F.

Boyd (NRC) from L. J:

Sobon (GE), dated September 1,, 1976.

3..

l.etter with enclosure, "Amendment 1

(December 1976) to Nark II Containment Dynamic Forcing Functions Information Report (OFFR),

NEDO/NEDE-21061, Revision 2,"

to 0.

O. Parr (NRC) from L. J.

Sobon (GE), dated February 2, 1977.

4.

, Letter with enclosure, "Amendment 2, (June 1977) to Nar k II Containment Dynamic Forcing Functions Information Report (DFFR), NED0-21061, Revision 2," to 0.

O. Parr (NRC) from L. J.

Sobon (GE), dated July 7, 1977.

Enclosed are seventy (70) copies of Amendment 2, Supplement 1 of the

OFFR, NED0-21061, covering the responses to the forty-five (45)

"Round 2" NRC staff questions (Reference

1) on the OFFR (Reference
2) and its supporting documents.

As shown in the question index, this Supplement includes the comp',ete responses to fifteen (15) questions, and two (2) of the four (4) items comprising one (1) additional question.

Of the questions and parts of questions remaining, eleven (11) items will be

.submitted as a "Supplement'to this Amen'dment in September 1977.

~yD 71~

GER ERALI ELECTRIC USNRC Mr. Olan 0. Parr Page 2

September 15, 1977 This Supplement has been prepared in a format with pagination for in-sertion in the OFFR directly following Amendment 1 (Reference 3), super-seding Amendment 2 (Reference

4) entirely.

To facilitate identification of the changes comprising Supplement 1,

a vertical line and the abbre-viation "Sl" have been added to the margin adjacent to each Supplement 1-item.

Those items without marginal notations comprise the original Amendment 2 (Reference 4).

Please replace OFFR pages A-29 through A-61 (Amendment 2) with the enclosed Supplement 1, and'iscard the replaced pages.

The planned supplements and other changes to this Amendment will be effected through similar page substitutions or expansion to ensure continuity both in subject matter and, chronology.

Any questions regarding this Supplement should be directed to L. H. Frauenholz, the Mark II Containment Licensing Engineer, telephone number (408) 925-2623.

Sincerely L. J.

Sobon, Manager BMR Containment Licensing Containment Improvement Programs LJS:LHF:rm/148'-149

Enclosures:

(70) cc:

H.

C.. Brinkman (Mark II Owners Group)

L.. S. Gifford (GE, Bethesda)

S. Minor-R. L. Tedesco