ML17261B139: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(2 intermediate revisions by the same user not shown)
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:ROCHESTER GAS AND ELECTRIC CORPORATION 89 EAST AVENUE, ROCHESTER, NEW YORK 14649 INSERVICE INSPECTION REPORT FOR THE THIRD INTERVAL (1990-1999)FIRST PERIOD~FIRST OUTAGE (1990)AT R.E.GINNA NUCLEAR POWER STATION REVISION 0 JULY 13, 1990 9008230232 900817 Ii PDR ADOCK 05000244 Q PDC A
{{#Wiki_filter:ROCHESTER GAS AND ELECTRIC CORPORATION 89 EAST AVENUE, ROCHESTER, NEW YORK 14649 INSERVICE INSPECTION REPORT FOR THE THIRD INTERVAL (1990 1999)
GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990-1999 Interval, First Outage 1990 Table of Contents Introduction and Synopsis Summary of Work Accomplished Class 1 Components Class 2 Components Class 3 Components High Energy Components Design Break Weld Examinations Consequential Break Weld Examinations
FIRST PERIOD~ FIRST OUTAGE (1990)
-Component Support Examinations Steam Generator System Pressure Tests Hydrostatic Testing Leakage Testing Snubber Program Visual Examinations Functional Testing Repair/Replacement Program Repairs Service Induced Rejectable Indications Code Rejectable Indications Replacements Erosion/Corrosion Program Attachment I ISI Program Summary Attachment II Erosion/Corrosion (Minwall)Program Summary Attachment III Miscellaneous NDE Summary l
AT R. E. GINNA NUCLEAR POWER STATION REVISION 0 JULY 13, 1990 9008230232 900817     Ii PDR ADOCK 05000244 Q               PDC
GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990-1999 Interval, First Outage 1990 INTRODUCTION AND SYNOPSIS: Inservice Inspection (ISI)activities during the 1990 Refueling Outage were performed on components of Class 1, 2, 3, High Energy Pipi'ng, Steam Generator Tubes and Snubbers.The examinations were initiated on 12 March 1990 and activities concluded on 7 May 1990.Examination methods included Visual Examination (VT), Liquid Penetrant Examination (PT), Magnetic Particle Examination (MT), Ultrasonic Examination (UT), Radiographic Examination (RT), Eddy Current Examination (ET), Functional Testing (FT)and System Hydrostatic Pressure and Leakage Tests.Personnel involved included the RG&E Materials Engineering and Inspection Services Section., Southwest Research Institute, Gilbert Commonwealth, Allen Nuclear Associates, NDE Technologies, Ginna Station Quality Control and the Ginna Station Results/Test Group.Additional Support Personnel involved, included individuals from the following departments:
 
Ginna Station Insulators, Maintenance, Electricians, Pipe Fitters, Health Physics, Turbine Maintenance, RG&E's General Maintenance and the Mechanical Engineering Group of the Engineering Department.
A GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990   1999 Interval, First Outage 1990 Table of Contents Introduction   and Synopsis Summary of Work Accomplished Class   1 Components Class   2 Components Class   3 Components High Energy Components Design Break Weld Examinations Consequential Break Weld Examinations Component Support Examinations Steam Generator System Pressure     Tests Hydrostatic Testing Leakage Testing Snubber Program Visual Examinations Functional Testing Repair/Replacement Program Repairs Service Induced Rejectable Indications Code Rejectable Indications Replacements Erosion/Corrosion Program Attachment   I       ISI Program Summary Attachment   II     Erosion/Corrosion (Minwall) Program Summary Attachment   III     Miscellaneous NDE Summary
~SMMARY OF~WOR ACC M LISHED: Note: A detailed summary of all components with associated results can be found in the Attachments.
 
I!*A total of 63 Class 1 components were examined during the 1990 Outage.The examination for these components consisted of 20 VT-1's, 11 VT-3's, 36 PT's, 3 MT's,,l RT, and 22 UT's.A total of 93 examinations were performed on Class 1 components.
l GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990 1999   Interval, First Outage 1990 INTRODUCTION AND SYNOPSIS:
Class 1 examinations were performed on the following components and/or system lines: Pressurizer.
Inservice Inspection (ISI) activities during the 1990 Refueling Outage were performed on components of Class 1, 2, 3, High Energy Pipi'ng, Steam Generator Tubes and Snubbers.       The examinations were initiated on 12 March 1990 and activities concluded on 7 May 1990. Examination methods included Visual Examination (VT), Liquid Penetrant Examination (PT), Magnetic Particle Examination (MT), Ultrasonic Examination (UT),
Radiographic Examination (RT), Eddy Current Examination (ET),
Functional Testing (FT) and System Hydrostatic Pressure and Leakage Tests.
Personnel involved included the RG&E Materials Engineering and Inspection Services Section., Southwest Research Institute, Gilbert Commonwealth, Allen Nuclear Associates, NDE Technologies, Ginna Station Quality Control and the Ginna Station Results/Test Group.
Additional Support Personnel involved, included individuals from the following departments: Ginna Station Insulators, Maintenance, Electricians, Pipe Fitters, Health Physics, Turbine Maintenance, RG&E's General Maintenance and the Mechanical Engineering Group of the Engineering Department.
~SMMARY OF   ~WOR ACC M LISHED:
Note:   A detailed   summary of all components with associated results   can be found     in the Attachments.
I!
* A total of   63 Class 1 components were examined during the 1990 Outage. The examination     for these components consisted of 20 VT-1's, 11 VT-3's, 36 PT's, 3 MT's,,l RT, and 22 UT's.       A total of 93 examinations were performed on Class 1 components.
Class   1 examinations     were performed on the following components and/or system lines:
Pressurizer.
Steam Generators.
Steam Generators.
Regenerative Heat Exchanger.
Regenerative   Heat Exchanger.
10" Pressurizer Surge Line;10-RC8-2501 2" Auxiliary Spray Line;2-CH5-2501 10" Safety Injection Line;10A-SI2-2501A  
10" Pressurizer Surge Line; 10-RC8-2501 2" Auxiliary Spray Line; 2-CH5-2501 10" Safety Injection Line; 10A-SI2-2501A
'h 6" Safety Injection (L.P.)Line;6A-RC-2501-B 4" Safety Injection (L.P.)Line;4A-RC-2501-B 6" Safety Injection (L.P.)Line;6A-RC-2501-A 2" Safety Injection Loop A Line;2C-SI2-2501 2" Safety Injection Loop B Line;2B-SI2-2501 2" Letdown Line;2B-RCO-2501-A 2" Letdown Line;2A-RCO-2501-B 2" Letdown Line;2A-CH4-2501 2" Charging Line;2B-CH5-2501 2" Alternate Charging Line;2A-CH5-2501 Reactor Coolant Pump B.Reactor Coolant Pump-Spare Flywheel.Valves.~SASS 2 CO PO ENTS'total of 75 Class 2 components were examined.The examination for these components consisted of 7 RT's, 19 UT's, 32 PT's, 14 MT's, 2 UTTK (Thickness Measurement), 10 VT-1's>and 35 VT-3's for a total of 119 examinations.
 
Class 2 examinations were performed on the following components and/or system lines: Non-Regenerative Heat Exchanger.
'h 6" Safety Injection (L.P. ) Line; 6A-RC-2501-B 4" Safety Injection (L.P.) Line; 4A-RC-2501-B 6" Safety Injection (L.P.) Line; 6A-RC-2501-A 2" Safety Injection Loop A Line; 2C-SI2-2501 2"
2" Safety Injection Loop B Line; 2B-SI2-2501 Letdown Line; 2B-RCO-2501-A 2" Letdown Line; 2A-RCO-2501-B 2" Letdown Line; 2A-CH4-2501 2" Charging Line; 2B-CH5-2501 2" Alternate Charging Line; 2A-CH5-2501 Reactor Coolant   Pump B.
Reactor Coolant   Pump Spare Flywheel.
Valves.
~SASS 2 CO PO ENTS' total of 75 Class 2 components were examined. The examination for these components consisted of 7 RT's, 19 UT's, 32 PT's, 14 MT's, 2 UTTK (Thickness Measurement), 10 VT-1's> and 35 VT-3's for a total of 119 examinations.
Class 2 examinations were performed on the following components and/or system lines:
Non-Regenerative Heat Exchanger.
Seal Water Heat Exchanger.
Seal Water Heat Exchanger.
Reactor Coolant Filter.Pulse Dampener Line;, 8A-CH-2502.
Reactor Coolant Filter.
Seal Water Injection Filters.Main Steam Loop A Line;30A-MS-600-1A.
Pulse Dampener Line;, 8A-CH-2502.
Main Steam Loop A Line;6B-MS-600-1A.
Seal Water Injection Filters.
Main Steam Loop B Line;30B-MS-600-1B.
Main Steam   Loop A Line; 30A-MS-600-1A.
Feedwater Loop A Line;14A-FW-900-1A.
Main Steam   Loop A Line; 6B-MS-600-1A.
Feedwater Loop B Line;14B-FW-900-1B.
Main Steam   Loop B Line; 30B-MS-600-1B.
L.P.Safety Injection; Line 10-SI-151.
Feedwater   Loop A Line; 14A-FW-900-1A.
L.P.Safety Injection; Line SA-SI-301B.
Feedwater   Loop B Line; 14B-FW-900-1B.
LE P Safety Injection; Line SA-SI-151.
L.P. Safety Injection; Line     10-SI-151.
L.P.Safety Injection; Line 8B-SI-151.
L.P. Safety Injection; Line     SA-SI-301B.
L.P.Safety Injection; Line SD-SI-301.
LE P   Safety Injection; Line   SA-SI-151.
LE PE Safety Injection; Line 6-AC-601.L.P.Safety Injection;.Line 6A-AC-601.
L.P. Safety Injection; Line     8B-SI-151.
L.P.Safety Injection; Line 4A-SI-301.
L.P. Safety Injection; Line     SD-SI-301.
H.P.Safety Injection; Line 4D-SI-1501.
LE PE Safety Injection; Line   6-AC-601.
H.P.Safety Injection;.
L.P. Safety Injection;.Line     6A-AC-601.
Line 4E-SI-1501.
L.P. Safety Injection; Line     4A-SI-301.
H.P.Safety Injection; Line 3B-SI-1501.
H.P. Safety Injection; Line     4D-SI-1501.
H.P.Safety Injection; Line 3C-SI-1501.
H.P. Safety Injection;. Line   4E-SI-1501.
H.P.Safety Injection; Line 3E-SI-1501
H.P. Safety Injection; Line     3B-SI-1501.
'.P.Safety Injection; Line 2A-SI-1501.
H.P. Safety Injection; Line     3C-SI-1501.
H.P.Safety Injection; Line 2D-SI-1501>>.
H.P. Safety Injection; Line     3E-SI-1501 Safety Injection; Line   2A-SI-1501.  '.P.
Residual Heat Removal;Line SFF-AC-601.
H.P. Safety Injection; Line     2D-SI-1501>>.
Residual Heat Removal;Line 6K-AC-151,  
Residual Heat Removal; Line     SFF-AC-601.
Residual Heat Removal; Line     6K-AC-151,


Residual Heat Removal;Line 10B-AC-601.
Residual Heat Removal; Line 10B-AC-601.
Residual Heat Removal;Line 10D-AC-601.
Residual Heat Removal; Line 10D-AC-601.
Residual'eat Removal;Line 10A-AC-601.
Residual'eat Removal; Line 10A-AC-601.
Residual Heat Removal;Line 10H-AC-601.
Residual Heat Removal; Line 10H-AC-601.
Residual Heat Removal;Line SC-AC-601.
Residual Heat Removal; Line SC-AC-601.
Residual Heat Removal;Line 6C-AC-601.
Residual Heat Removal; Line 6C-AC-601.
Residual Heat Removal;Line SX-AC-601.
Residual Heat Removal; Line SX-AC-601.
Containment Spray;Line 6C-SI-301.
Containment Spray; Line 6C-SI-301.
Containment, Spray;Line 6E-SI-301.
Containment, Spray; Line 6E-SI-301.
A total of 21 Class 3 components were examined by the VT-3 visual technique, Class 3 component examinations were performed on the following system lines: Component Coolant Pumps Discharge to Component Coolant Heat Exchanger Line: SB-AC5-152.
A total of 21 Class     3 components were examined by the VT-3 visual technique, Class   3   component examinations   were performed on the following system   lines:
Component Coolant Pumps Discharge to Component Coolant Heat Exchanger Line: SB-AC5-152.
Service Water to Component Cooling and Spent Fuel Pit Heat Exchangers Line: 20A-SWO-125-9.
Service Water to Component Cooling and Spent Fuel Pit Heat Exchangers Line: 20A-SWO-125-9.
Service Water Intermediate Building to A 8c B Chillers Line: 6B-SW0-125-9.
Service Water Intermediate Building to   A 8c B Chillers Line:
Auxiliary Feedwater Pumps Discharge-Intermediate Building Line: 3A-FW7-900-1B.
6B-SW0-125-9.
Standby Auxiliary Feedwater from Penetration 119 to A S/G Feedwater Header.Standby Auxiliary Feedwater From Penetration 119 to Auxiliary Feedwater Pump C Line: 3A-FW8-902-A.
Auxiliary Feedwater Pumps Discharge-Intermediate     Building Line: 3A-FW7-900-1B.
Standby Auxiliary Feedwater from'Penetration 123 to B S/G Feedwater Header.Standby Auxiliary Feedwater Service Water Supply to Standby Auxiliary Feedwater Pump D Line: 4A-FW8-152-B.
Standby Auxiliary Feedwater from Penetration 119     to A S/G Feedwater Header.
Twenty Three (23)High Energy Piping components were examined during the 1990 Outage.The examinations for these components consisted of 16 VT-1's, 6 VT-3's, 6 PT's, 18 MT's, 11 UT's, 1 UTTK and 16 RT's for a total of 74 examinations.
Standby Auxiliary Feedwater From Penetration 119     to Auxiliary Feedwater Pump C Line: 3A-FW8-902-A.
High Energy component examinations were performed on the following system lines:~Desi n Break Weld Examinations:
Standby Auxiliary Feedwater from 'Penetration 123     to B S/G Feedwater Header.
Main Steam-Loop A Outside Containment, Line: 30A-MS-600-1A.
Standby Auxiliary Feedwater Service Water Supply     to Standby Auxiliary Feedwater Pump D Line: 4A-FW8-152-B.
Main Steam-Loop B Outside Containment, Line: 30B-MS-600-.1B.
Twenty Three (23) High Energy Piping components were examined during the 1990 Outage. The examinations for these components consisted of 16 VT-1's, 6 VT-3's, 6 PT's, 18 MT's, 11 UT's, 1 UTTK and 16 RT's for a total of 74 examinations.
Feedwater-Loop A Outside Containment, Line: 14A-FW-900-1A.
High Energy component examinations were performed on the following system   lines:
Feedwater-Loop B Outside Containment, Line: 14B-FW-900-1A.
~Desi n   Break Weld Examinations:
sn Conse uential Break Weld Examinations:
Main Steam Loop A Outside Containment, Line: 30A-MS-600-1A.
Main Steam-Loop A Outside Containment, Line: 30A-MS-600-1A.
Main Steam Loop B Outside Containment, Line: 30B-MS-600-.1B.
Main Steam-Loop B Outside Containment, Line: 30B-MS-600-1B.
Feedwater Loop A Outside Containment, Line: 14A-FW-900-1A.
Main Steam-Turbine Building, Line: 24A-MS-600-1A.
Feedwater Loop B Outside Containment, Line: 14B-FW-900-1A.
Feedwater-Turbine Building, Line: 20-FW-900-1.
 
Feedwater-Turbine Building, Line: 8-FW-900-1.
sn Conse   uential Break   Weld Examinations:
Feedwater-Loop A Outside Containment, Line:'4A-FW-900-1A.
Main Steam     Loop A Outside Containment,   Line: 30A-MS-600-1A.
Feedwater-Loop B Outside Containment, Line: 14B-FW-900-1B.
Main Steam     Loop B Outside Containment,   Line: 30B-MS-600-1B.
Main Steam, Line: 36-MS-600-1.
Main Steam     Turbine Building, Line: 24A-MS-600-1A.
Main Steam, Line: 24A-MS-600-1A.
Feedwater     Turbine Building, Line: 20-FW-900-1.
Main Steam, Line: 24B-MS-600-1B.
Feedwater     Turbine Building, Line: 8-FW-900-1.
Feedwater, Line: 14A-FW-900-1A.
Feedwater     Loop A Outside Containment, Line:'4A-FW-900-1A.
Feedwater, Line: 14B-FW-900-1B.
Feedwater     Loop B Outside Containment, Line: 14B-FW-900-1B.
STEAN GENERATOR~BING: Eddy Current Examinations were performed on tubes in the A and B Steam Generators.
Main Steam,   Line: 36-MS-600-1.
The following Eddy Current examinations were performed during the 1990 Outage: 1~2~3~4, 5.Open Generator Tubes, Previously identified degradation greater than 20%.Open Generator Tubes, 20%Minimum, Rotating Random Sample Full Length (Total).Open Generator Tubes, 100%of all unsleeved tubes.Hot Leg Tube End through First Tube Support Hot Leg.Sleeved Generator Tubes, 20%Random Sample of each type.Sleeve End to Sleeve End (minimum).
Main Steam,   Line: 24A-MS-600-1A.
MRPC of Row 1 U-Bends and Row 2 U-Bends that are a part, of the 20%Random Sample Full Length.The following information summarizes the initial pre-outage and post-outage tube status as well as the planned and completed Eddy Current work scope for Steam Generators A 8I B.STEAM GENERATOR A: Total Tubes Out of Service (plugged)Sleeved Tubes Open Unsleeved Tubes 3260 173 172 2915
Main Steam,   Line: 24B-MS-600-1B.
Feedwater,   Line: 14A-FW-900-1A.
Feedwater,   Line: 14B-FW-900-1B.
STEAN GENERATOR     ~BING:
Eddy Current Examinations were performed on tubes       in the A and B Steam Generators.
The following Eddy     Current examinations were performed during the 1990 Outage:
1 ~   Open Generator Tubes, Previously   identified degradation greater than   20%.
2 ~    Open Generator Tubes, 20% Minimum, Rotating Random Sample Full Length (Total).
3 ~    Open Generator Tubes, 100% of all unsleeved tubes.
Hot Leg Tube End through First Tube Support Hot Leg.
4,    Sleeved Generator Tubes, 20% Random Sample of each type.
Sleeve End to Sleeve End (minimum).
: 5. MRPC of Row 1 U-Bends and Row 2 U-Bends that are a part, of the 20% Random Sample Full Length.
The following information summarizes the initial pre-outage and post-outage tube status as well as the planned and completed Eddy Current work scope for Steam Generators A 8I B.
STEAM GENERATOR     A:
Total Tubes                       3260 Out of Service (plugged)           173 Sleeved Tubes                       172 Open Unsleeved Tubes               2915
 
Req'd    Number  Number Min      ~Pro  m'd ~Ins  t'd Com  leted Hot, Leg  to ¹1  TSP                2915        2915      2915      100.0%
Full Length    (20X Random)          583          586        585    100.3X Previous Ind.    >  20%                                            100 OX Sleeves                                35          36.        35    100.0%
Total Tubes                            3260 Out of Service (plugged)                197 Sleeved Tubes                            223 Open Unsleeved Tubes                    2840 Note:  A  total of  75  tubes were repaired.
(  51 sleeved  R  24 plugged = 75 repairs)
STEAM GENERATOR    B:
Total Tubes                            3260 Out of Service (plugged)                340 Sleeved Tubes                            642 Open Unsleeved      Tubes              2278 Req'd    Number    Number        X Min      ~Pro m'  ~In s  t'  Com  leted Hot Leg to ¹1 TSP                  2278        2278      2278    100.0X Full Length  (20X Random)          456          461        460    100.9%
Previous Ind.    >  20X              19          19        19    100.0X Sleeves                              129          131        131    101.6X Deplugged Tubes (F/L)                  28          28        28    100    OX
 
u~C


Hot, Leg to¹1 TSP Full Length (20X Random)Previous Ind.>20%Sleeves Req'd Min 2915 583 35 Number~Pro m'd 2915 586 36.Number~Ins t'd 2915 585 35 Com leted 100.0%100.3X 100 OX 100.0%Total Tubes Out of Service (plugged)Sleeved Tubes Open Unsleeved Tubes 3260 197 223 2840 Note: A total of 75 tubes were repaired.(51 sleeved R 24 plugged=75 repairs)STEAM GENERATOR B: Total Tubes Out of Service (plugged)Sleeved Tubes Open Unsleeved Tubes 3260 340 642 2278 Hot Leg to¹1 TSP Full Length (20X Random)Previous Ind.>20X Sleeves Deplugged Tubes (F/L)Req'd Min 2278 456 19 129 28 Number~Pro m'2278 461 19 131 28 Number~In s t'2278 460 19 131 28 X Com leted 100.0X 100.9%100.0X 101.6X 100 OX
Steam Generator     "B" Post-Outa   e Tube   Status:
*u~C Steam Generator"B" Post-Outa e Tube Status: Total Tubes Out of Service (plugged)Sleeved Tubes Open Unsleeved Tubes 3260 332 832 (~)2096 Notes: A total of 211 tubes were repaired.(191 sleeved&, 20 (4)plugged=211 repairs)(4)=One previous post-outage B&W Sleeved Tube was plugged and is included in the'20 tubes identified in the above note.Eddy Current Examination details are documented in the"Summary Examination Report for the 1990 Steam Generator Eddy Current Inspection".
Total Tubes                           3260 Out of Service (plugged)               332 Sleeved Tubes                           832 (~)
SYSTEM PRESSURE~EST: H drostatic:
Open Unsleeved Tubes                  2096 Notes: A total of 211   tubes were repaired.
Four (4)Hydrostatic tests and associated VT-2 examinations were performed during the 1990.Outage.Hydrostatic tests were performed on the following:
(191 sleeved   &, 20 (4) plugged = 211 repairs)
Procedure RSSP-15.7.1 RSSP-13.16 RSSP-13.17 RSSP-13.18 Discre tion Charging System through Regenerative Heat Exchanger.
(4) = One previous post-outage B&W Sleeved Tube     was plugged and is included in the'20 tubes identified in the above note.
CVCS Hold-up Tank"A".CVCS Hold-up Tank"B".CVCS Hold-up Tank"C".Two Hydrostatic examinations were scheduled for the 1990 outage but were not performed.
Eddy Current Examination details are documented in the "Summary Examination Report for the 1990 Steam Generator Eddy Current Inspection".
One'xamination was scheduled in error and was subsequently rescheduled for the correct outage, The second examination scheduled pertained to a non-class vessel and associated piping that was initially performed during the Second Interval ISI Program.The associated examination boundary is not under the jurisdiction of Appendix B of the Quality Assurance Manual and was removed from the Third Interval ISI Program.Two Leakage Examinations'ere performed during the 1990 Outage and are listed below: Reactor Coolant System Leakage Examination (PT-7)Containment Spray Rings  
SYSTEM PRESSURE ~EST:
H drostatic:
Four (4) Hydrostatic tests and associated         VT-2 examinations were performed during the 1990. Outage.
Hydrostatic tests were performed on the following:
Procedure               Discre tion RSSP-15.7.1   Charging System through Regenerative     Heat Exchanger.
RSSP-13.16    CVCS Hold-up Tank "A".
RSSP-13.17    CVCS Hold-up Tank "B".
RSSP-13.18    CVCS Hold-up Tank "C".
Two Hydrostatic examinations were scheduled for the 1990 outage but   were not performed.       One'xamination was scheduled in error and was subsequently rescheduled for the correct outage, The second examination scheduled pertained to a non-class vessel and associated piping that was initially performed during the Second Interval ISI Program. The associated examination boundary is not under the jurisdiction of Appendix B of the Quality Assurance Manual and was removed from the Third Interval ISI Program.
Two Leakage   Examinations'ere performed during the       1990 Outage and are   listed   below:
Reactor Coolant System Leakage Examination (PT-7)
Containment Spray Rings


Five (5)Leakage examinations were also performed to fulfill the Second Interval Program when Ginna Station was placed back in service in 1989.The Leakage examinations included the following.
Five (5) Leakage examinations were also performed to             fulfill the Second Interval Program when Ginna Station was placed back in service in 1989. The Leakage examinations included the following.
CVCS Hold-Up Tanks&, Piping.CVCS Charging R Letdown outside Containment.
CVCS   Hold-Up Tanks &, Piping.
CVCS Boric Acid Storage Tanks R Piping.CVCS Boric Acid Evaporizer
CVCS   Charging R Letdown outside Containment.
-Demineralizers
CVCS   Boric Acid Storage Tanks R Piping.
~Diesel Generators.
CVCS   Boric Acid Evaporizer - Demineralizers           ~
~NBBER~PR GRA Visual Examinations:
Diesel Generators.
A total of 147 Snubber components were inspected that required 148 VT-3 examinations.
~NBBER   ~PR GRA Visual Examinations:
These examinations were performed to satisfy Ginna Station Technical Specification requirements.
A total of   147 Snubber components were inspected that required 148 VT-3   examinations. These examinations were performed to satisfy Ginna Station Technical Specification requirements.
A Mechanical Snubber on the Feedwater Loop"B" System;FWU-54, was rejected during the close of the 1989 Outage.This component was reviewed by Engineering under NCR G89-743 and resulted in a"use-as-is" determination.
A Mechanical Snubber on the Feedwater Loop "B" System; FWU-54, was rejected during the close of the 1989 Outage. This component was reviewed by Engineering under NCR G89-743 and resulted in a "use-as-is" determination.
Snubber examinations were performed on the following components and/or system lines: Steam Generator"A".Steam Generator"B".Turbine Driven Auxiliary Feedwater Pump Suction Line: 4A-SW-125-1.
Snubber examinations were performed on the               following components and/or system lines:
Auxiliary Feedwater Pump Discharge-Intermediate Building Lines: 3D-FW7-900-1
Steam Generator     "A".
~3A-FW7-900-1A.
Steam Generator     "B".
Turbine Driven Auxiliary Feedwater             Pump Suction Line: 4A-SW-125-1.
Auxiliary Feedwater Pump Discharge               Intermediate Building Lines: 3D-FW7-900-1   ~
3A-FW7-900-1A.
3J-FW7-900-1.
3J-FW7-900-1.
3A-FW7-900-1B.
3A-FW7-900-1B.
Line 118: Line 175:
Steam Generator 1B Blowdown Line: 2C-MS-600-1B.
Steam Generator 1B Blowdown Line: 2C-MS-600-1B.
Auxiliary Cooling Line: 3C-AC-152.
Auxiliary Cooling Line: 3C-AC-152.
Auxiliary Cooling System from Pump Cooling Outlet to Penetration 126 Line: 3E-AC6-152
Auxiliary Cooling System from Pump Cooling Outlet to Penetration 126 Line: 3E-AC6-152 Cooling Line: 4B-AC-152. 'uxiliary 2-IN..Letdown Line: 2A-CH4-2501.
'uxiliary Cooling Line: 4B-AC-152.
2-IN. Alternate Charging Lines: 2-CH-2501R.
2-IN..Letdown Line: 2A-CH4-2501.
2-IN.Alternate Charging Lines: 2-CH-2501R.
2A-CH5-2501.
2A-CH5-2501.
CVCS Letdown Line: 2G-CH-601.
CVCS Letdown Line: 2G-CH-601.
Reactor Coolant Pump"B" Seal Water Line: 2AB-CH-2502.
Reactor Coolant Pump "B" Seal Water Line: 2AB-CH-2502.
Reactor Coolant.Pump"A" Seal Water Line: 2U-CH-151.
Reactor Coolant. Pump "A" Seal Water Line: 2U-CH-151.
CVCS Letdown Line: 2H-CH-601.
CVCS Letdown Line: 2H-CH-601.
CVCS Letdown Line: 2N-CH-151.
CVCS Letdown Line: 2N-CH-151.
Feedwater Loop"A" Line: 14A-FW-900-1A.
Feedwater Loop "A" Line: 14A-FW-900-1A.
Feedwater Loop"B" Line: 14B-FW-900-1B.
Feedwater Loop "B" Line: 14B-FW-900-1B.
Main Steam Loop"A" Line: 30A-MS-600-1A.
Main Steam Loop "A" Line: 30A-MS-600-1A.
Main Steam Loop"B" Line: 30B-MS-600-1'  
Main Steam Loop "B" Line: 30B-MS-600-1'
'I fc Main Steam Loop"B" Riser Line: 6B-MS-600-1B.
 
Main Steam Loop"A" Riser Line: 6B-MS-600-1A.
'I fc
 
Main Steam Loop "B" Riser Line: 6B-MS-600-1B.
Main Steam Loop "A" Riser Line: 6B-MS-600-1A.
Main Steam Supply to Auxiliary Feedwater Pump Turbine Lines: 6B-MS-600-1.
Main Steam Supply to Auxiliary Feedwater Pump Turbine Lines: 6B-MS-600-1.
6A-MS-600-1.
6A-MS-600-1.
Low Head Safety Injection Line: 6-AC-601.Residual Heat, Removal Line: 10A-AC7-2501-A.
Low Head Safety Injection Line: 6-AC-601.
Residual Heat, Removal Line: 10A-AC7-2501-A.
Residual Heat Removal Line: 8B-AC-601.
Residual Heat Removal Line: 8B-AC-601.
.Residual Heat Removal Line: 10-AC-601.
        . Residual Heat Removal Line: 10-AC-601.
Residual Heat Removal Line: 6D-AC-601.
Residual Heat Removal Line: 6D-AC-601.
Residual Heat Removal Line: 10E-AC-601.
Residual Heat Removal Line: 10E-AC-601.
Line 146: Line 205:
Safety Injection Line: 6K-AC-151.
Safety Injection Line: 6K-AC-151.
Safety Injection Line: 10-SI-151.
Safety Injection Line: 10-SI-151.
Safety Injection.Line: 4-SI-301.Safety Injection Line: 8H-SI-151.
Safety Injection .Line: 4-SI-301.
Safety Injection Line: 8H-SI-151.
Safety Injection Lines: 10A-SI2-2501-B.
Safety Injection Lines: 10A-SI2-2501-B.
10A-SI2-2501-A.
10A-SI2-2501-A.
Line 152: Line 212:
Service Water to A8rB Diesel Generator Water Coolers Lines: 10B-SW0-125-9.
Service Water to A8rB Diesel Generator Water Coolers Lines: 10B-SW0-125-9.
8G-SW0-125-9B.
8G-SW0-125-9B.
Service Water-Intermediate Building From 16" Header to Penetrations 312-320 Line: 8A-SW0-125-9.
Service Water   Intermediate Building   From 16" Header   to Penetrations   312-320 Line: 8A-SW0-125-9.
Standby Auxiliary Feedwater from Penetration 123 to B S/G Feedwater Header Line: 3-FW-900-1B.
Standby Auxiliary Feedwater from Penetration     123 to B S/G Feedwater Header Line: 3-FW-900-1B.
Standby Auxiliary Feedwater from Penetration 119 TO A S/G Feedwater Header Line: 3-FW-900-1A.
Standby Auxiliary Feedwater from Penetration     119 TO A S/G Feedwater Header Line: 3-FW-900-1A.
Pressurizer Relief from Pressurizer to Relief Manifold Lines: 6AP-RC-602.
Pressurizer Relief from Pressurizer to Relief Manifold Lines: 6AP-RC-602.
6BP-RC-602.
6BP-RC-602.
Power Pressurizer Relief Lines: 3BP-RC-602.
Power Pressurizer Relief Lines: 3BP-RC-602.
3BP-RC-2501.
3BP-RC-2501.
Functional
Functional ~Teatin A total of 15 Snubbers were Functionally Tested (FT) during the 1990 outage. Twelve of the Fifteen Supports were Mechanical Snubbers and the remaining three were Hydraulic Snubbers.           One Snubber AFU-227 was originally scheduled for functional testing but was substituted by AFU-109 during the outage, Snubber Functional Testing (FT) was performed on the       following components and/or system lines:
~Teatin A total of 15 Snubbers were Functionally Tested (FT)during the 1990 outage.Twelve of the Fifteen Supports were Mechanical Snubbers and the remaining three were Hydraulic Snubbers.One Snubber AFU-227 was originally scheduled for functional testing but was substituted by AFU-109 during the outage, Snubber Functional Testing (FT)was performed on the following components and/or system lines: Steam Generator"A".Auxiliary Feedwater Pump Discharge, Lines: 3A-FW7-900-1B 3A-FW-900-1A Reactor Coolant Pump 1B Seal Water, Line: 2AB-CH-2502.  
Steam Generator     "A".
Auxiliary Feedwater     Pump Discharge, Lines: 3A-FW7-900-1B 3A-FW-900-1A Reactor Coolant     Pump 1B   Seal Water, Line: 2AB-CH-2502.


Chemical 8c Volume Control System Letdown, Line: 2H-CH-601 Feedwater Loop"A", Line: 14A-FW-900-1A Feedwater Loop"B", Line: 14B-FW-900-1B Residual Heat Removal System, Line: 10G-AC-601 Safety Injection, Line: 10A-SI2-2501-B Pressurizer Relief from Pressurizer to Relief Manifold, Line: 6BP-RC-602 Power Pressurizer Relief, Line: 3BP-RC-602 REPAIR PROGRAM: The Repair Program as described under the Ginna Station Quality Assurance Manual Appendix B identifies the component jurisdiction and associated requirements.
Chemical 8c Volume Control System Letdown, Line: 2H-CH-601 Feedwater Loop "A", Line: 14A-FW-900-1A Feedwater Loop "B", Line: 14B-FW-900-1B Residual Heat Removal System, Line: 10G-AC-601 Safety Injection, Line: 10A-SI2-2501-B Pressurizer Relief from Pressurizer to Relief Manifold, Line: 6BP-RC-602 Power Pressurizer Relief, Line: 3BP-RC-602 REPAIR PROGRAM:
The Rochester Gas&, Electric Repair Program for Ginna Station covers both Servic'e Induced and Code Rejectable Repairs.A"Service Induced Reject" occurs when an item that is under Appendix B jurisdiction contains an indication that is beyond acceptable standards that was caused during its'nservice life.A"Code Reject" occurs when an item that is under Appendix B jurisdiction contains indications or other rejectable conditions that were not service induced.Code rejects include but are not'limited to items such as arc strikes or tightening of loose bolting.Three service induced rejectable components were identified during the 1990 Outage.The following listing provides a summary of the component and the associated exp'anded examination scope.ASME Class: 1~S etem: 2" Alternate Charging Line: 2A-CH5-2501 Com onent: Variable Spring, CVU-51 A 3/4" rod was bent from the vertical position.NCR 90-167 was generated and corrective action taken.The rod was replaced under Work Order¹(WO¹)9021606.This support was reexamined and acceptable.
The Repair Program as     described under the Ginna Station Quality Assurance Manual Appendix       B identifies the component jurisdiction and associated requirements. The Rochester Gas &,
~Ex anded Examination
Electric Repair Program for Ginna Station covers both Servic'e Induced and Code Rejectable Repairs.       A "Service Induced Reject" occurs when an item that is under Appendix B jurisdiction contains an indication that is beyond acceptable standards that was caused during its'nservice life. A "Code Reject" occurs when an item that is under Appendix B jurisdiction contains indications or other rejectable conditions that were not service induced. Code rejects include but are not 'limited to items such as arc strikes or tightening of loose bolting.
~Sco e: The following components were examined on the system: 1.Support CVU-50,"U-Bolt" type: Examination revealed no other service induced recordable indications.
Three service induced rejectable components were identified during the 1990 Outage. The following listing provides a summary of the component and the associated exp'anded examination scope.
2.Support CVU-5, Variable Spring: Examination revealed no other service induced recordable indications.  
ASME   Class:   1
    ~S etem: 2" Alternate Charging Line: 2A-CH5-2501 Com   onent: Variable Spring, CVU-51 A 3/4" rod was bent from the vertical position. NCR 90-167 was generated and corrective action taken. The rod was replaced under Work Order ¹ (WO¹) 9021606. This support was reexamined and acceptable.
    ~Ex anded Examination   ~Sco e:
The following components were examined on the system:
: 1. Support CVU-50, "U-Bolt" type: Examination revealed   no other service induced recordable indications.
: 2. Support CVU-5, Variable Spring: Examination revealed no other service induced recordable indications.


II.ASME Class: 2~S stem: Low Pressure Safety Injection Line: SB-SI-151 The Rod in the Spring Can is locked 85 the space in front of the can is 1/2" while the rod touches the rear of the can.NCR 90-091 was generated for Engineering disposition.
II. ASME   Class:   2
Work Order (W04)9021614 was initiated to correct the situation.
    ~S stem: Low Pressure     Safety Injection Line: SB-SI-151 The Rod   in the Spring Can is locked the space in front 85 of the can is 1/2" while the rod touches the rear of the can. NCR 90-091 was generated for Engineering disposition. Work Order (W04) 9021614 was initiated to correct the situation. The support, was reexamined'with no recordable indications and acceptable.
The support, was reexamined'with no recordable indications and acceptable.
    ~Ex ended Examination     ~gco e:
~Ex ended Examination
The following components were examined on the system:
~gco e: The following components were examined on the system: 1.Support RHU-101, Rigid Support: Examination revealed no other service induced recordable indications.
: 1. Support RHU-101, Rigid Support: Examination revealed no other service induced recordable indications.
2.Support RHU-130, Variable Spring: Examination revealed no other service induced recordable indications.
: 2. Support RHU-130, Variable Spring: Examination revealed no other service induced recordable indications.
1 III.ASME Class: 2~S stem: High Pressure Safety Injection Line: 3E-SI-1501 Com onent: Rigid Support, SIU-58 Code Service Induced Re'ectable Indication:
1 III. ASME   Class:   2
A loose nut was identified on top of the support while the associated bottom nut can be turned by hand.NCR 90-107 was generated for Engineering disposition.
    ~S stem:   High Pressure   Safety Injection Line: 3E-SI-1501 Com   onent: Rigid Support, SIU-58 Code   Service Induced Re 'ectable Indication:
Work Order (W04)9021810 was initiated to perform the repairs.The support was reexamined after repairs and acceptable,~Ex ended Examination
A loose nut was identified on top of the support while the associated bottom nut can be turned by hand. NCR 90-107 was generated for Engineering disposition. Work Order (W04) 9021810 was initiated to perform the repairs. The support was reexamined after repairs and acceptable,
~Sco e: The following components were examined on the system: 1.Support SIU-57, Rigid Support: Examination revealed no other service induced recordable indications.
    ~Ex ended Examination     ~Sco e:
2.Support SIU-59, Rigid Support: The Examination revealed no other service induced recordable indications.
The following components were examined on the system:
3.Support SIU-66>Rigid Restraint:
: 1. Support SIU-57, Rigid Support: Examination revealed no other service induced recordable indications.
Examination revealed no other service induced recordable indications.
: 2. Support SIU-59, Rigid Support: The Examination revealed no other service induced recordable indications.
fp Code The following.listing of 40 components provides an accounting of Code Respectable Indications identified during the 1990 Outage.ASME Class: 1~S stem: Low Pressure Safety lnjeotion System: Line: 6A-RC-2501-B Slag inclusions located in the crotch area were identified in the Northeast and Southeast Lug Plates.NCR 90-163 was generated.
: 3. Support SIU-66> Rigid Restraint: Examination revealed no other service induced recordable indications.
An Engineering evaluation was performed that resulted in a use-as-is disposition.
2~ASME Class: 1~S stem: 2" Safety Znjeotion Loop A Line: 2C-SI2-2501 Code Re ectable Indication:
A rough weld with numerous pores on the weld center line was identified.
NDE personnel"blended out" the indication with a file.The area was reexamined after blending and acceptable.
3~ASME Class: 2~S stem: Main Steam Loop A Line: 30A-MS-600-1A Com onent: Anchor in Penetration 401(outside containment),PS-A Code Re ectable Indication:
Lack of thread engagement was identified and reported on NCR 90-186.Engineering reviewed and performed an evaluation with a resulting disposition of use-as-is.
4~ASME Class: 2~S stem: Feedwater Loop A Line: 14A-FW-900-1A Coin onent: Variable Spring, FWU-1 The top nut does not have full thread engagement.
NCR 90-173 was generated.
Engineering review of this reportable condition indicated that it was addressed under NCR G83-132 that had a disposition of use-as-is, acceptable.
~'1i f'<(>lw S.ASME Class: 2~S stem: Low Pressure Safety Injection System Line: SA-SI-301B This Inspection identified loose Micarta block on the North side of the guide.NCR 90-160 was generated for Engineering review.A use-as-is disposition was based on the pipe to block gaps being within the requirements with the associated nuts tack welded in place as addressed by FCR-3092-145 dated 5-11-87.6.ASME Class: 2~S stem: Residual Heat Removal System Line: 10B-AC-601 The examination reported linear respectable indications in the weld.Additional augmented NDE investigation revealed that the indications were actually score marks that appeared to be mechanical in origin.The final disposition of this weld is acceptable.
ASME Class: 2~S stem: Low Pressure Safety Injection System Line: 4A-SI-301 Code Re'ectable Indication:
The Integral Welded attachment to the Elbow pressure boundary was'not welded all around.NCR 90-164 was generated for Engineering review and evaluation.
A disposition of use-as-is was made based upon the adequacy of the existing weld.8..ASME Class: 2 I~S stem: High pressure Safety Injection System Line: 3E-SI-1501 L Examination revealed that the ear on the pipe clamp is bent inward.NCR 90-247 was generated for Engineering review and evaluation.
The replacement of the clamp was performed under WO&#xb9;9021837.Reexamination of the component was acceptable.


fr"j'f ASME Class: 2~S stem: High Pressure Safety Injection System Line: 3E-SI-1501 Examination revealed that a bushing was located in the upper clamp section while none were located in the lower clamp.NCR 90-090 was generated for review and disposition.
fp Code The following .listing of 40 components        provides an accounting of Code Respectable    Indications identified    during the 1990 Outage.
Quality Control revealed that the bushing is a spacer and only required on one bolt.The component is acceptable, use-as-is.
ASME   Class: 1
ASME Class: 2~S stem: Containment.
    ~S stem: Low Pressure     Safety lnjeotion System:
Spray System Line: 6E-SI-301 Code Re'ectable Indication:
Line: 6A-RC-2501-B Slag inclusions located   in the crotch area    were identified in the Northeast      and Southeast  Lug  Plates. NCR 90-163 was   generated. An  Engineering evaluation    was  performed that resulted in    a use-as-is disposition.
The Integrally Welded attachment to the pressure boundary is missing 1.5" of weld in the crotch area, an arc strike is also situated adJacent to the weld.NCR 90-089 was generated for Engineering review and evaluation.
2 ~  ASME   Class: 1
Engineerings'isposition of use-as-is on the missing weld was based on EWR 2512 design analysis, ME 39 Attachment Bl.The respectable arc strike was removed under WOg 9021570.Subsequent reexamination was acceptable.
    ~S stem: 2" Safety Znjeotion Loop      A Line: 2C-SI2-2501 Code Re   ectable Indication:
ASME Class: High Energy Program Appendix B~S stem: Feedwater Loop B Out.side Containment.
A rough weld with numerous pores on the weld center line was identified.       NDE personnel "blended out" the indication with a file. The area was reexamined after blending and acceptable.
Line: 14B-FW-900-1B Code Re'ectable Indication:
3 ~  ASME   Class: 2
A rejectable Linear Indication 1/4" long was identified and reported on NCR 90-123.A disposition for repair employing a metal removal method was initiated under WOg 9021386.Reexamination after the repair activity was acceptable.
    ~S stem: Main Steam Loop A Line: 30A-MS-600-1A Com onent: Anchor in Penetration        401(outside containment),PS-A Code Re   ectable Indication:
ASME Class: High Energy Program Appendix B~S stem: Feedwater Outside Containment Line: 14A-FW-900-1A Com onent: Mechanical Snubber, FWU-21 This support was rejected due to insulation obstructing the snubber movement.The insulation, was tight against the snubber, 6" away on the clamp side.NCR 90-200 was initiated to resolve the situation.
Lack of thread engagement was identified and reported on NCR 90-186. Engineering reviewed and performed an evaluation with a resulting disposition of use-as-is.
Engineering dispositioned the NCR as rework and instructed that the clamp be moved and rotated to insure that the final clamp position will not restrict the snubber freedom of movement in the hot position.Reexamination of the support was acceptable.
4 ~  ASME   Class: 2
P
    ~S stem: Feedwater Loop      A Line: 14A-FW-900-1A Coin  onent: Variable Spring,   FWU-1 The top nut does not have    full  thread engagement. NCR 90-173 was generated. Engineering review of this reportable condition indicated that that had a disposition of it was addressed under NCR G83-132 use-as-isacceptable.
$t ASME Class: 3~S stem: Service Water to Component Cooling A Spent Fuel Pit Heat Exchangers.
Line: 20A-SWO-125-9 Four(4)bo'its were identified and rejected for being 1/8" short of full thread enga'gement.
NCR 90;090 was generated for Engineering review.Upon Engineerings'eview 85 evaluation, a use-as-is disposition was made due to the associated loads are in compression.
ASME Class: 3~S stem: Auxiliary Feedwater Pump Discharge-Intermediate Building.Line: 3A-FW7-900-1B Code Re'ectable Indication:
Inspection revealed that the support did not conform to the drawing requirements.
NCR 90-108 was initiated and reported to Engineering for disposition.
Engineering review indicated that Revision 1 of the drawing should have been used.The support is acceptable as is and agrees to Revision 1 drawing requirements.
ASME Class: 3~S stem: Standby Auxiliary Feedwater from Penetration 119 to A Steam Generator Feedwater Header, Line:.3C-FW-900-1A Com onent: Variable Spring, AFW-30 The inspection revealed that the can setting of 580 lbs.did not agree with the 540 lbs.identified in ME-256 Specification.
NCR 90-185 was generated for Engineering review.The disposition initiated work to reset the spring can-to resolve the discrepancy.
Reexamination i'ndicated no recordable indications, acceptable.
123 to B ASME.Class: 3~S stem: Standby Auxiliary Feedwater from Penetration Steam Generator Feedwater Header.Line: 3C-FW-900-1B
*"-Code Re ectable Indication:
Results of the inspection revealed that the support cold setting of 2 1/8" should be 3 1/2".NCR 90-109 was generated.
A review of the data by Engineering indicated that the Gilbert Scales show the setting to be 2 1/2".The reading of 2 1/8" is acceptable.
ME-256 Specification for this component will be corrected and revised.(14) jt 17.ASME Class: 3~S stem: Standby Auxiliary Feedwater , Service Water supply to Standby Auxiliary Feedwater Pump D.Line: 4A-FWS-152-B Oode Re'ectable Indication:
Bottom lug weld on the East side has lack of sufficient weld at the toe.NCR 90-188 was generated to resolve this problem.Engineerings'isposition indicated that repairs are required.Upon completion of repair activities, a reexamination of the component was performed and acceptable.
This repair was performed on a component under the jurisdiction of"Construction".
This component is not under the jurisdiction of Appendix B until"Construction" rework turnover.18.ASME Class: Snubber Program Appendix B~S stem: Auxiliary Feedwater Pumps Discharge, Xntermediate Building.Line: 3A-FW-900-1A
\Inspection revealed that the bolt holding the fluid reservoir was loose.NCR 90-104 was generated.
Corrective action was performed by replacing the support with another Snubber under WO&#xb9;9020415.Reexamination of the support was acceptable.
19.ASME Class: Snubber Program Appendix B~S stem: Feedwater Loop A Line: 14A-FW-900-1A The top of the Snubber was hitting the mounting brackets.NCR 90-246 was generated to document this condition.
Engineering performed an evaluation and dispositioned the condition use-as-is.
The disposition of use-as-is was based on the angular tolerance and clearance on the snubber being adequate to perform its function.20.ASME Class: Snubber Program Appendix B~S stem: Feedwater Loop B Line: 14B-FW-900-1B Insulation on valve 4012 was resting on the snubber that may interfere with and cause binding of the snubber during operation.
NCR 90-103 was generated to resolve this situation.
Engineering disposition of reduceing the thickness of the insulation on the valve in order to provide the needed clearance was performed.
Reexamination after repairs was acceptable.
(15)


21.ASME Class: Snubber Program Appendix B~S stem: Feedwater Loop A Line: 14B-FW-900-1B The Inspection revealed that the locknut was not tight on the snubber side, the cotter pin was missing and a turnbuckle on the component was not shown on the drawing.NCR 90-172 was generated.
~ '
Repairs were initiated to correct the reported items.The snubber was reexamined after repairs and found to be acceptable.
1i f'
22.ASME Class: Snubber Program Appendix B~S stem: Main Steam Loop A Line'.30A-MS-600-1A The snubber was installed backwards to the way the drawing indicated.
<(  >
NCR 90-101 was generated for Engineering evaluation.
lw
The'esults of the evaluation indicated that the snubber may be rotated 180 degrees without changing its function.A disposition of use-as-is was made.23'SME Class: Snubber Program Appendix B~Sstem: Safety Injection System Line: 10A-SI2-2501-A Code Re ectable Indication:
 
The inspection revealed that the snubber tang was binding on the pipe clamp.NCR 90-187 was initiated to address this problem.A repair was performed and the snubber was subsequently reexamined and found acceptable.
S. ASME  Class:  2
24.ASME Class: Snubber Program Appendix B~S stern: Service Water to A ik B Diesel Generator Water Coolers.Line: 10B-SWO-125-9 The examination indicated that loose nuts were found on the West side of the Snubber pipe clamp.NCR 90-208 was initiated for Engineering review 80 disposition.
    ~S stem: Low Pressure        Safety Injection System Line: SA-SI-301B This Inspection identified loose Micarta block on the North side of the guide. NCR 90-160 was generated for Engineering review. A use-as-is disposition was based on the pipe to block gaps being within the requirements with the associated nuts tack welded in place as addressed by FCR-3092-145 dated 5-11-87.
Repairs were initiated to tighten the loose nuts.Reexamination of the snubber indicated the component was acceptable.
: 6. ASME  Class:  2
il~(g'r  
    ~S stem: Residual Heat Removal System Line: 10B-AC-601 The examination reported linear respectable indications in the weld. Additional augmented NDE investigation revealed that the indications were actually score marks that appeared to be mechanical in origin. The final disposition of this weld is acceptable.
-ASME Class: Snubber Program Appendix B~S stem: Standby Auxiliary Peedwater from Penetration 123 to B Steam Generator Feedwater Header.Line: 3C-PW-900-1B Inspection revealed that the 2 1/16" observed setting did not compare with the 3 1/2" documented cold setting in ME-256 Specification.
ASME  Class:  2
NCR 90-109 was generated to resolve this problem.Engineering revealed that the Gilbert scales show the proper setting to be 2 1/2".Engineering disposition of use-as-is was made along with a proposed revision to ME-256 Specification.
    ~S stem: Low Pressure        Safety Injection System Line: 4A-SI-301 Code Re  'ectable Indication:
26.ASME Class: Snubber Program Appendix B~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: SAP-RC-602 Code Re'ectable Indication:
The  Integral    Welded attachment to the Elbow pressure boundary was      'not  welded all around. NCR 90-164 was generated for Engineering      review  and evaluation. A disposition of use-as-is was made based upon the adequacy of the existing weld.
The Snubber hits the base plate at the wall and is missing its I.D.Tag.NCR 90-184 was generated.
: 8. .ASME  Class:  2                                              I
Engineering evaluation indicated a use-as-is disposition.
    ~S stem: High pressure Safety Injection System Line: 3E-SI-1501 L
The base plate does not impair the snubber function.A new I.D.Tag was installed.
Examination revealed that the ear on the pipe clamp is bent inward. NCR 90-247 was generated for Engineering review and evaluation.        The replacement of the clamp was performed under WO&#xb9; 9021837.          Reexamination of the component was acceptable.
The reexamination of the snubber was acceptable.
 
27'SME Class: Snubber Program Appendix B~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 The Inspection revealed that, the snubber was missing an I.D.Tag.NCR 90-184 was generated.
fr"j'f ASME  Class:  2
A new I.D.Tag was installed.
~S  stem: High Pressure    Safety Injection System Line: 3E-SI-1501 Examination revealed that a bushing was located in the upper clamp section while none were located in the lower clamp. NCR 90-090 was generated for review and disposition.
The reexamination was acceptable.
Quality Control revealed that the bushing is a spacer and only required    on one bolt. The component  is acceptable, use-as-is.
28.ASME Class: Snubber Program Appendix B~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6BP-RC-602 The Inspection indicated that the snubber was missing an I.D.Tag.NCR 90-184 was generated.
ASME    Class:  2
A new I.D.Tag was installed.
~S  stem: Containment. Spray System Line: 6E-SI-301 Code Re 'ectable Indication:
The reexamination was acceptable.
The Integrally Welded    attachment to the pressure boundary is missing 1.5" of weld in the crotch area, an arc strike is also situated adJacent to the weld. NCR 90-089 was generated for Engineering review and evaluation.
ASME Class: Snubber Program Appendix B~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 Com onent: Hydraulic Snubber, N607 The Inspection indicated that the snubber was missing an I.D.Tag.NCR 90-184 was generated.
of use-as-is  on  the missing weld was based on Engineerings'isposition EWR 2512    design analysis,  ME 39 Attachment Bl.                    The respectable arc strike was removed under WOg 9021570. Subsequent reexamination was acceptable.
A new I.D.Tag was installed.
ASME    Class: High Energy Program Appendix B
The reexamination was acceptable.
~S  stem: Feedwater Loop B Out.side Containment.
Line: 14B-FW-900-1B Code Re    'ectable Indication:
A rejectable Linear Indication 1/4" long was identified and reported on NCR 90-123. A disposition for repair employing a metal removal method was initiated under WOg 9021386.
Reexamination after the repair activity was acceptable.
ASME    Class: High Energy Program Appendix                    B
~S  stem: Feedwater Outside Containment Line: 14A-FW-900-1A Com onent: Mechanical Snubber, FWU-21 This support was rejected due to insulation obstructing the snubber movement. The insulation, was tight against the snubber, 6" away on the clamp side. NCR 90-200 was initiated to resolve the situation. Engineering dispositioned the NCR as rework and instructed that the clamp be moved and rotated to insure that the final clamp position will not restrict the snubber freedom of movement in the hot position. Reexamination of the support was acceptable.                                                P
 
$t ASME    Class:  3
~S stem: Service Water to Component Cooling        A Spent Fuel  Pit Heat Exchangers.
Line: 20A-SWO-125-9 Four(4) bo'its were identified and rejected for being 1/8" short of full thread enga'gement.      NCR 90;090 was generated    for Engineering      review. Upon  Engineerings'eview    85 evaluation,    a use-as-is disposition was made due to the associated loads are in compression.
ASME   Class:  3
~S stem:    Auxiliary  Feedwater  Pump  Discharge  Intermediate Building.
Line: 3A-FW7-900-1B Code Re 'ectable Indication:
Inspection revealed that the support did not conform to the drawing requirements. NCR 90-108 was initiated and reported to Engineering for disposition. Engineering review indicated that Revision 1 of the drawing should have been used.      The support is acceptable as is and agrees to Revision 1 drawing requirements.
ASME    Class:  3
~S  stem: Standby    Auxiliary  Feedwater from Penetration    119  to  A Steam Generator  Feedwater Header, Line:    .3C-FW-900-1A Com  onent: Variable Spring, AFW-30 The inspection revealed that the can setting of 580 lbs.
did not agree with the 540 lbs. identified in ME-256 Specification. NCR 90-185 was generated for Engineering review. The disposition initiated work to reset the spring can-to resolve the discrepancy. Reexamination i'ndicated no recordable indications, acceptable.
ASME    .Class:  3
~S  stem: Standby    Auxiliary Feedwater from Penetration      123  to  B Steam Generator  Feedwater Header.
Line:    3C-FW-900-1B Code Re      ectable Indication:
Results of the inspection revealed that the support cold setting of 2 1/8" should be 3 1/2". NCR 90-109 was generated.
A review of the data by Engineering indicated that the Gilbert Scales show the setting to be 2 1/2". The reading of 2 1/8" is acceptable. ME-256 Specification for this component will be corrected and revised.
(14)
 
j t
: 17. ASME  Class:  3
    ~S stem: Standby Auxiliary Feedwater , Service Water supply to Standby Auxiliary Feedwater Pump D.
Line: 4A-FWS-152-B Oode Re  'ectable Indication:
Bottom lug weld on the East side has lack of sufficient weld at the toe. NCR 90-188 was generated to resolve this problem. Engineerings'isposition indicated that repairs are required. Upon completion of repair activities, a reexamination of the component was performed and acceptable.
This repair was performed on a component under the jurisdiction of "Construction". This component is not under the jurisdiction of Appendix B until "Construction" rework turnover.
: 18. ASME  Class: Snubber Program Appendix B
    ~S  stem:  Auxiliary Feedwater Pumps Discharge,  Xntermediate Building.
Line: 3A-FW-900-1A
                                                            \
Inspection revealed that the bolt holding the fluid reservoir was loose. NCR 90-104 was generated. Corrective action was performed by replacing the support with another Snubber under WO &#xb9;9020415.      Reexamination of the support was acceptable.
: 19. ASME    Class: Snubber Program Appendix   B
    ~S stem:  Feedwater Loop A Line: 14A-FW-900-1A The top of the Snubber was hitting the mounting brackets.
NCR    90-246 was generated to document this condition.
Engineering performed an evaluation and dispositioned the condition use-as-is.      The disposition of use-as-is was based on the angular tolerance and clearance on the snubber being adequate to perform its function.
: 20. ASME    Class: Snubber Program Appendix    B
    ~S  stem: Feedwater Loop B Line: 14B-FW-900-1B Insulation on valve 4012 was resting on the snubber that may interfere with and cause binding of the snubber during operation. NCR 90-103 was generated to resolve this situation. Engineering disposition of reduceing the thickness of the insulation on the valve in order to provide the needed clearance was performed. Reexamination after repairs was acceptable.
(15)
: 21. ASME    Class: Snubber Program Appendix  B
    ~S  stem: Feedwater Loop A Line: 14B-FW-900-1B The Inspection revealed that the locknut was not tight on the snubber side, the cotter pin was missing and a turnbuckle on the component was not shown on the drawing. NCR 90-172 was generated. Repairs were initiated to correct the reported items. The snubber was reexamined after repairs and found to be   acceptable.
: 22. ASME   Class: Snubber Program Appendix   B
    ~S stem: Main Steam Loop A Line'. 30A-MS-600-1A The snubber was installed backwards to the way the drawing   indicated. NCR 90-101 was generated for Engineering evaluation. The'esults of the evaluation indicated that the snubber may be rotated 180 degrees without changing its function. A disposition of use-as-is was made.
23 'SME     Class: Snubber Program Appendix   B
    ~Sstem:   Safety Injection System Line: 10A-SI2-2501-A Code Re ectable Indication:
The inspection revealed   that the snubber tang was binding on   the pipe clamp. NCR 90-187 was initiated to address this problem. A repair was performed and the snubber was subsequently reexamined and found acceptable.
: 24. ASME   Class: Snubber Program Appendix B
    ~S stern: Service Water to A ik B Diesel Generator Water Coolers.
Line: 10B-SWO-125-9 The examination indicated that loose nuts were found on the West side of the Snubber pipe clamp. NCR 90-208 was initiated for Engineering review 80 disposition. Repairs were initiated to tighten the loose nuts. Reexamination of the snubber indicated the component was acceptable.
 
il
  ~ (
g'r
 
-     ASME
      ~S Class: Snubber Program Appendix B stem: Standby Auxiliary Peedwater from Penetration Steam Generator Feedwater Header.
Line: 3C-PW-900-1B 123 to  B Inspection revealed that the 2 1/16" observed setting did not compare with the 3 1/2" documented cold setting in ME-256 Specification. NCR 90-109 was generated to resolve this problem. Engineering revealed that the Gilbert scales show the proper setting to be 2 1/2". Engineering disposition of use-as-is was made along with a proposed revision to ME-256   Specification.
: 26. ASME   Class: Snubber Program Appendix B
      ~S stem: Pressurizer Relief from Pressurizer     to Relief Manifold Line: SAP-RC-602 Code Re 'ectable Indication:
The Snubber hits the base plate at the wall and is missing its I.D. Tag. NCR 90-184 was generated.     Engineering evaluation indicated a use-as-is disposition. The base plate does not impair the snubber function. A new I.D. Tag was installed. The reexamination of the snubber was acceptable.
27 'SME     Class: Snubber Program Appendix B
      ~S stem: Pressurizer Relief from Pressurizer     to Relief Manifold Line: 6AP-RC-602 The Inspection revealed that, the snubber was missing an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.
: 28. ASME   Class: Snubber Program Appendix B
      ~S stem: Pressurizer Relief from Pressurizer     to Relief Manifold Line: 6BP-RC-602 The Inspection indicated that the snubber was missing   an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.
ASME   Class: Snubber Program Appendix B
      ~S stem: Pressurizer Relief from Pressurizer     to Relief Manifold Line: 6AP-RC-602 Com onent: Hydraulic Snubber,     N607 The Inspection indicated that the snubber was missing   an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.
(17)
(17)
F~a f-~
 
30.ASME Class: Snubber Program Appendix B~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 The Snubber hits the base plate at the wall and is missing its I.D.Tag.NCR 90-184 was generated.
F
Engineering evaluation indicated a use-as-is disposition.
~a f- ~
The base plate does not impair the snubber function.A new I.D.Tag was installed.
: 30. ASME   Class: Snubber Program Appendix B
The Reexamination of the snubber was acceptable.
      ~S stem: Pressurizer Relief from Pressurizer     to Relief Manifold Line: 6AP-RC-602 The Snubber hits the base plate at the wall and is missing   its I.D. Tag. NCR 90-184 was generated. Engineering evaluation indicated a use-as-is disposition. The base plate does not impair the snubber function. A new I.D. Tag was installed. The Reexamination of the snubber was acceptable.
31.l ASME Class: Snubber Program Appendix B~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6BP-RC-602 The Inspection indicated that the snubber was missing an I.D.Tag.NCR 90-184 was generated.
: 31. ASME   Class: Snubber Program Appendix B l ~S stem: Pressurizer Relief from Pressurizer     to Relief Manifold Line: 6BP-RC-602 The Inspection indicated that the snubber was missing     an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.
A new I.D.Tag was installed.
: 32. ASME   Class: Snubber Program Appendix B
The reexamination was acceptable.
      ~S stem: Pressurizer Relief from Pressurizer     to Relief Manifold Line: 6AP-RC-602 The'nspection indicated that the snubber was missing an I.D. Tag and a cotter key was broken at top of the component near the wall. NCR 90-184 was generated.         Engineering disposition indicated that the cotter key should be repaired and a new I.D. Tag installed.     The reexamination was acceptable.
32.ASME Class: Snubber Program Appendix B~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 The'nspection indicated that the snubber was missing an I.D.Tag and a cotter key was broken at top of the component near the wall.NCR 90-184 was generated.
33 'SME Class: Snubber Program Appendix B
Engineering disposition indicated that the cotter key should be repaired and a new I.D.Tag installed.
      ~S stem: Power Pressurizer Relief Line Line: 3BP-RC-2501 Inspection indicated that the cotter key at top of the component was not engaged     100X and was deformed. NCR 90-112 was generated. Engineering review indicated a repair should       be made. The reexamination was acceptable.
The reexamination was acceptable.
34,   ASME   Class: Snubber Program Appendix B
33'SME Class: Snubber Program Appendix B~S stem: Power Pressurizer Relief Line Line: 3BP-RC-2501 Inspection indicated that the cotter key at top of the component was not engaged 100X and was deformed.NCR 90-112 was generated.
      ~S stem: Power Pressurizer Relief Line Line: 3BP-RC-2501 Code Re 'ectable Indication:
Engineering review indicated a repair should be made.The reexamination was acceptable.
The Inspection revealed that the snubber had a broken cotter key and the clamp end bolting had lack of thread engagement.     NCR 90-112 was generated for Engineering review.
34, ASME Class: Snubber Program Appendix B~S stem: Power Pressurizer Relief Line Line: 3BP-RC-2501 Code Re'ectable Indication:
An Engineering design analysis was performed to address the lack of thread engagement. The dispositioned of use-as-is was made by Engineering.     Work was initiated on the support wi'th the cotter key being replaced.       Reexamination of the component was acceptable.
The Inspection revealed that the snubber had a broken cotter key and the clamp end bolting had lack of thread engagement.
NCR 90-112 was generated for Engineering review.An Engineering design analysis was performed to address the lack of thread engagement.
The dispositioned of use-as-is was made by Engineering.
Work was initiated on the support wi'th the cotter key being replaced.Reexamination of the component was acceptable.
(18)
(18)
KI 0 35.ASME Class: 3~S stem: Auxiliary.
 
Feedwater System Line: 2A-FW-900-1 This 4" Crane Check Valve had cracks on the gasket surface and valve body.NCR 90-096-was generated for Engineering review.The disposition was made to remove the indications and perform a weld repair under WO&#xb9;9021452.Reexamination was performed and acceptable.
KI 0
The NDE reexamination record was documented under the Maintenance NDE Summary Number 900023.36.ASME Class: 2~S stem: Low Pressure Safety Injection Line Line: 10-SI-151 Two linear indications, 1/8" 86 1/2" was identified in the 2" Weld-0-Let to Pipe Weld.NCR 90-102 was generated.
: 35. ASME   Class: 3
Engineering reviewed this condition and recommended a repair be performed by metal removal process under WO&#xb9;9021568.A reexamination was performed of the repaired area and was acceptable.
    ~S stem: Auxiliary. Feedwater System Line: 2A-FW-900-1 This 4" Crane Check Valve had cracks on the gasket surface and valve body. NCR 90-096- was generated for Engineering review. The disposition was made to remove the indications and perform a weld repair under WO &#xb9; 9021452.
37.ASME Class: 2~S stem: Steam Generator Blowdown Line: 2E-MS-600-IA The wall thickness was 68K T Nominal that equates to a minimum reading of 0.150".In 1988&, 1989 the thickness of this section was 0.170".NCR 90-150 was generated for Engineering review&.disposition.
Reexamination was performed and acceptable. The NDE reexamination record was documented under the Maintenance NDE Summary   Number 900023.
An interim use disposition was made to repair the area by grinding and rewelding.
: 36. ASME   Class: 2
Work was performed under WO&#xb9;9021695.Replacement of this.component is scheduled for the 1991 Outage under EWR 4324C or reinspected in 1991 if the EWR is deferred.38.ASME Class: 2~S stem: Steam Generator Blowdown Line: 2E-MS-600-1A The wall thickness was 64X T Nominal that equates to a minimum reading of 0.140".In 1988 the thickness of this section was 0'80" and in 1989 the thickness'was 0.160".NCR 90-150 was generated for Engineering review&, disposition.
    ~S stem: Low Pressure   Safety Injection Line Line: 10-SI-151 Two linear indications, 1/8" 86 1/2" was identified in the 2" Weld-0-Let to Pipe Weld.       NCR 90-102 was generated.
An interim use disposition was made to repair the area by grinding and rewelding.
Engineering reviewed this condition and recommended a repair be performed by metal removal process under WO&#xb9; 9021568.       A reexamination was performed of the repaired area and was acceptable.
Work was performed under WO&#xb9;9021695.Replacement of this component is scheduled for the 1991 Outage under EWR 4324C or reinspected in 1991 if the EWR is deferred.  
: 37. ASME   Class: 2
('I~4i+V" I 1" 39.ASME Class: 2~S stem: Steam Generator Blowdown Line: SB-'MS-600-1A During a Maintenance activity to remove Valve 3411 internals, it was discovered that scoring occurred on the seat.Steam cuts was also observed on the face of the valve bonnet.NCR 90-234 was generated to address the problem.Repairs were performed under WO&#xb9;9000043.Upon completion of welding 86 subsequent machining operations, reexamination of the component was acceptable.
    ~S stem: Steam Generator Blowdown Line: 2E-MS-600-IA The wall thickness was 68K T Nominal that equates to a minimum reading of 0.150". In 1988 &, 1989 the thickness of this section was 0.170". NCR 90-150 was generated for Engineering review &. disposition. An interim use disposition was made to repair the area by grinding and rewelding.       Work was performed under WO&#xb9; 9021695.     Replacement of this
40.ASME Class: Class 3~S stem: Service Cooling Water Line: 2B-SW-152 Inspection indicated that a 3/32" wide by 1/8" long through wall indication was identified in the 2" pipe by support SWU-570.The through wall indication was caused by work activities associated with EWR 2512.NCR G90-022 was generated for resolution.
    .component is scheduled for the 1991 Outage under EWR 4324C or reinspected in 1991   if the EWR is deferred.
Engineering review indicated that a weld repair be performed.
: 38. ASME   Class: 2
A Code weld repair and subsequent examinations were performed by Projects under SM 2512.129.The NDE consisted of surface examinations, UT thickness measurements and Hydrostatic testing.All repair cycle examinations and testing were acceptable.
    ~S stem: Steam Generator Blowdown Line: 2E-MS-600-1A The wall thickness was 64X T Nominal that equates to a minimum reading of 0.140". In 1988 the thickness of this section was 0 '80" and in 1989 the thickness'was 0.160". NCR 90-150 was generated for Engineering review &, disposition. An interim use disposition was made to repair the area by grinding and rewelding. Work was performed under WO&#xb9; 9021695.
Appendix B of the Ginna Station Quality Assurance Manual identifies the component jurisdiction and requirements for the Replacement Program.The term Replacement includes both Replacements and Modifications.
Replacement of this component is scheduled for the 1991 Outage under EWR 4324C or reinspected in 1991     if the EWR is deferred.
Replacements and/or Modifications that were initiated prior to 1 January 1990 and installed during the 1990 Outage are under the jurisdiction of the Second Interval Appendix B Program requirements.
 
Any Replacements and/or Modifications that were initiated after 1 January 1990 are under the Third Interval Appendix B Program requirements.
(
During the 1990 Outage, no Major Modifications were initiated and/or installed to the Third Interval Program requirements.
    'I
~4i
+V" I 1"
: 39. ASME   Class:     2
      ~S stem: Steam Generator Blowdown Line: SB-'MS-600-1A During     a Maintenance activity to remove Valve 3411 internals, seat.
it was discovered that scoring occurred Steam cuts was also observed on the face of on the the valve bonnet. NCR 90-234 was generated to address the problem.
Repairs were performed under WO&#xb9; 9000043. Upon completion of welding   86   subsequent machining operations, reexamination of the component was acceptable.
: 40. ASME   Class: Class 3
      ~S stem: Service Cooling Water Line:   2B-SW-152 Inspection indicated that a 3/32" wide by 1/8" long through wall indication was identified in the 2" pipe by support SWU-570.     The through wall indication was caused by work activities associated with EWR 2512. NCR G90-022 was generated for resolution. Engineering review indicated that a weld repair be performed. A Code weld repair and subsequent examinations were performed by Projects under SM 2512.129. The NDE consisted of surface examinations, UT thickness measurements and Hydrostatic testing. All repair cycle examinations and testing were acceptable.
Appendix     B of the Ginna Station Quality Assurance Manual identifies the         component jurisdiction and requirements for the Replacement Program. The term Replacement includes both Replacements and Modifications.
Replacements and/or Modifications that were initiated prior to 1 January 1990 and installed during the 1990 Outage are under the jurisdiction of the Second Interval Appendix B Program requirements.         Any Replacements and/or Modifications that were initiated after 1 January 1990 are under the Third Interval Appendix B Program requirements.           During the 1990 Outage, no Major Modifications were initiated and/or installed to the Third Interval Program requirements.
The following Replacements and Minor Modifications were performed during the 1990 Outage and conforms to the Third Interval Program requirements.
The following Replacements and Minor Modifications were performed during the 1990 Outage and conforms to the Third Interval Program requirements.
1.ASME Class: 3~S stem: Chemical&Volume Control Line: 2C-CH6-151 (20)  
: 1. ASME   Class:     3
      ~S stem: Chemical     & Volume Control Line: 2C-CH6-151 (20)


t Re lacement~Summer: The ITT Grinnell Valve Bonnet was an approved equilivant replacement.
t Re   lacement ~Summer : The ITT Grinnell Valve Bonnet was an approved equilivant replacement. Code required reconciliation and verification was performed and is documented under TSR 90-
Code required reconciliation and verification was performed and is documented under TSR 90-25.This bonnet was ordered under PO NEG-87329 and was installed under Work Order 4 9000185.A VT-2 Leakage examination was performed and acceptable.
: 25. This bonnet was ordered under PO NEG-87329 and was installed under Work Order 4 9000185. A VT-2 Leakage examination was performed and acceptable.
2~ASME Class: 3~S stem: Auxiliary Eeedwater Line: 3A-FW-900-1A Re lacement~Summer: The Crane Valve Disk assembly was a"like and kind" replacement.
2 ~   ASME     Class: 3
The Code required verification was performed.
      ~S stem: Auxiliary Eeedwater Line: 3A-FW-900-1A Re   lacement   ~Summer : The Crane Valve Disk assembly was a "like   and kind" replacement. The Code required verification was performed. The Crane seating and disc assembly was ordered under PO NQ 10274CSD, serial number 159953102 and installed under Work Order g 9021448. A VT-2 Leakage examination was performed and acceptable.
The Crane seating and disc assembly was ordered under PO NQ 10274CSD, serial number 159953102 and installed under Work Order g 9021448.A VT-2 Leakage examination was performed and acceptable.
EROSIO     CORR SION     ~NW~LL ~POGRAN:
EROSIO CORR SION~NW~LL~POGRAN: A Total of 312 Components were examined during the 1990 Outage.The breakdoun of this total number is as follows: 154 components were of pipes, 108 components were of elbows, 28 components were of Tees'-, 19 components were of reducers and 3 components were nozzles.Component Thickness measurements were performed.on the following systems: A/B Feedwater Pump Discharge to 5 A/B Heater.Feedwater Cleanup to Condenser East Wall.Heaters 4 A/B to Feedwater Suction.Condensate Pump&, Heater Drain Tank Discharge to Fee Low Pressure Downcomers.
A   Total of   312 Components   were examined during the 1990 Outage. The breakdoun of         this total number is as follows: 154 components were of pipes,         108 components were of elbows, 28 components were of Tees'-,       19 components were of reducers and 3 components were nozzles.
s Low Pressure Downcomers in West Condenser.
Component Thickness measurements         were performed .on the following systems:
A/B Feedwater Pump Discharge to 5 A/B Heater.
Feedwater Cleanup to Condenser East Wall.
Heaters 4 A/B to Feedwater Suction.
Condensate Pump &, Heater Drain Tank Discharge to Fee dwater Suction.
Low Pressure Downcomers.                                   s Low Pressure Downcomers in West Condenser.
Low Pressure Downcomers in East Condenser.
Low Pressure Downcomers in East Condenser.
MSR lA, 1B 2nd Pass Drain.MSR 2A, 2B 2nd Pass Drain.MSR lA, 1B 2nd Pass Drain to 5A H.P.H.&Condenser.
MSR lA, 1B 2nd Pass Drain.
MSR 2A, 2B 2nd Pass Drain to 5B H.P.H.&Condenser.
MSR 2A, 2B 2nd Pass Drain.
MSR,1A 4th Pass to 5A Heater.MSR 1B 4th Pass to 5B Heater.MSR 1A&.1B 4th Pass to Condenser.
MSR lA, 1B 2nd Pass Drain to 5A H.P.H. & Condenser.
MSR 2A 4th Pass to 5A Heater.MSR 2B 4th Pass to 5B Heater.MSR 2A&2B 4th Pass to Condenser.
MSR 2A, 2B 2nd Pass Drain to 5B H.P.H. & Condenser.
1A, 2A&.3A L.P.H.Drains to Condenser.
MSR,1A 4th Pass to 5A Heater.
Steam Extraction to Preseparator B&4B L.P.H.Steam Extraction to Preseparator A&4A L.P.H.Condensate Booster Pumps to Hydrogen Coolers.MSR 1A&1B to Heater Drain Tank.MSR 2A&2B to Heater Drain Tank.dwater Suction.  
MSR 1B 4th Pass to 5B Heater.
MSR 1A &. 1B 4th Pass to Condenser.
MSR 2A 4th Pass to 5A Heater.
MSR 2B 4th Pass to 5B Heater.
MSR 2A & 2B 4th Pass to Condenser.
1A, 2A &. 3A L.P.H. Drains to Condenser.
Steam   Extraction to Preseparator B & 4B L.P.H.
Steam   Extraction to Preseparator A & 4A L.P.H.
Condensate Booster Pumps to Hydrogen Coolers.
MSR 1A & 1B to Heater Drain Tank.
MSR 2A & 2B     to Heater Drain Tank.


5A H.P.H.Drain to 4A L.P.H.5B H.P.H.Drain to 4B L.P.H.Preseparator A/B to Heater Drain Tank 8c Condenser.
5A H.P.H. Drain to 4A L.P.H.
Preseparator A/B to Heater Drain Tank.Turbine Driven Auxiliary Feedwater Pump to Discharge Lines.Auxiliary Feedwater Pump A to Discharge Lines.Auxiliary Feedwater Pump B to Discharge Lines.Steam Extraction to 5A R 5B H.P.H.Feedwater Discharge, Turbine Building.Steam Generator Blowdown Lines, (Intermediate Building)Steam Generator Blowdown Lines, (Turbine Building)Steam Generator 1A Blowdoun Lines, (Containment Building)Steam Generator 1B Blowdoun Lines, (Containment Building)Feedw'ater Recirculation (CV-18).Feedwater Recirculation (CV-19).Main Feedwater Pump Bypass.Steam Generator Blowdoun to Condenser.
5B H.P.H. Drain to 4B L.P.H.
Service Mater in Screen House.Heater Drain Tank to Condenser, Main Steam Dump to Condenser.
Preseparator A/B to Heater Drain Tank 8c Condenser.
Preseparator A/B to Heater Drain Tank.
Turbine Driven Auxiliary Feedwater Pump to Discharge Lines.
Auxiliary Feedwater Pump A to Discharge Lines.
Auxiliary Feedwater Pump B to Discharge Lines.
Steam Extraction to 5A R 5B H.P.H.
Feedwater Discharge, Turbine Building.
Steam Generator Blowdown Lines, (Intermediate Building)
Steam Generator Blowdown Lines, (Turbine Building)
Steam Generator 1A Blowdoun Lines, (Containment Building)
Steam Generator 1B Blowdoun Lines, (Containment Building)
Feedw'ater Recirculation (CV-18).
Feedwater Recirculation (CV-19).
Main Feedwater Pump Bypass.
Steam Generator Blowdoun to Condenser.
Service Mater in Screen House.
Heater Drain Tank to Condenser, Main Steam Dump to Condenser.
Blowdown Tank to Condenser.
Blowdown Tank to Condenser.
Blowdown Tank to 3A Low Pressure Heater.Gland Steam Discharge to Gland Steam Condenser.
Blowdown Tank to 3A Low Pressure Heater.
Preseparator Drain to Preseparator Vent.4B Low Pressure Heater Vent.Prepared By: Frank A.Klepacki ISI Engineer 7-]3 PO I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspections and employed by The Hartford Steam Boiler Inspection and Insurance Company have inspected and/or verified that the components described within this report and associated Attachments during the stated reporting time frame, and state to the best of my knowledge and belief, the Owner has performed examinations and corrective measures described in this Report..Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Gland Steam Discharge to Gland Steam Condenser.
Reviewed By: ANII's Signature 7 js 5"o Date Approved By: Michael J.Sa ori.to Supervisor, Materi.'als Engineering NDE Level III (22) t'ef D, GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990-1999 Interval, First Outage 1990 Attachment I gU1~A4+A.CLASS 1 COMPONENTS:
Preseparator Drain to Preseparator Vent.
e Summary Number 004400 005000 Com onent Surge Line Nozzle to Reducer Weld;SLNSEW Safety Nozzle&#xb9;1 to Safe End;RC-273-I NDE Exam PT UT PT UT Results PT h.UT, no recordable indications.
4B Low Pressure Heater Vent.
Limitations due to ID Plate-acceptable.
Prepared By:                               7-]3 PO Frank A. Klepacki ISI Engineer I, the undersigned,   holding a valid commission issued by the National Board of   Boiler and Pressure Vessel Inspections and employed by   The Hartford Steam Boiler Inspection and Insurance Company   have inspected and/or verified that the components described within this report and associated Attachments during the stated reporting time frame, and state to the best of my knowledge and belief, the Owner has performed examinations and corrective measures described in this Report.. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
PT 8r.UT, no recordable indications
Reviewed By:                                               7 js 5"o ANII's Signature                            Date Approved By:
-acceptable.
Michael J. Sa ori.to Supervisor, Materi.'als Engineering NDE Level III (22)
005200 Safety Nozzle&#xb9;2 to Safe End;-RC-273-S PT UT PT&UT, no recordable indications.
 
Limitations, 1" downstream due to reducer-acceptable.
t' ef D,
005600 Manway Bolting, 16 total.VT-1 UT MT VT-1 8c UT, no recordable indications.
 
MT required only when removed-bolting not removed.Acceptable.
GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990 1999 Interval, First   Outage 1990 Attachment I gU1~A4+
2~~gg&'l'h=~a=a Summary NDE Exam Results 006000 Elbow to Safe End PT Inlet Nozzle Weld;UT PL-FW-I-ASW 006200 Outlet Nozzle Safe PT End to Elbow Weld;UT PL-FW-IX-ASW PT Ec UT, no recordable indications, unable to skew 45 degrees due to curved shoe acceptable.
A. CLASS   1 COMPONENTS:
PT 8c UT, no recordable indications, unable to skew 45 degrees due to curved shoe.No upstream exam due to nozzle-acceptable.
e Summary                         NDE Number     Com onent           Exam              Results 004400    Surge Line Nozzle     PT     PT h. UT, no recordable to Reducer Weld;      UT      indications. Limitations SLNSEW                        due to ID Plate -acceptable.
006430 Inlet Manway Nuts;16 Total.VT-1 VT-1, MT 8c UT, no recordable UT indications
005000    Safety Nozzle &#xb9;1      PT      PT 8r. UT, no recordable to Safe End;          UT      indications     acceptable.
-acceptable.
RC-273-I 005200     Safety Nozzle &#xb9;2     PT     PT & UT, no     recordable to Safe  End;-        UT      indications. Limitations, RC-273-S                      1" downstream due     to reducer     acceptable.
MT C
005600     Manway Bolting,     VT-1   VT-1   8c UT, no recordable 16  total.            UT      indications.     MT required MT      only when removed-bolting not removed. Acceptable.
Summary NDE Exam Results 006435 Inlet Manway Studs;VT-1 16 Total.UT MT VT-1, MT 8c UT, no recordable ,indications
2 Summary
-acceptable.
        ~ ~gg               &'l NDE h=~ a=a Exam               Results 006000     Elbow to Safe End   PT      PT Ec  UT, no  recordable Inlet Nozzle Weld;   UT     indications, unable to      skew PL-FW-I-ASW                   45 degrees due to curved shoe acceptable.
Summary NDE Exam Results 009200 Component Support VT-3 VT-3, no recordable indications Hanger;RHE-8-PR1 acceptable.
006200    Outlet Nozzle Safe    PT      PT 8c UT, no recordable End to Elbow Weld;    UT      indications, unable to       skew PL-FW-IX-ASW                  45 degrees due to curved shoe.
4~tt R'll'B Summary NDE Exam Results 014000 Safe End to Pipe UT Weld'PT 014100 Pipe to Pipe Weld;UT B PT PT;no recordable indications.
No upstream exam due to nozzle
UT;no recordable indications, UT,Geom: 2 indications upstream acceptable.
                                        -acceptable.
a.PT;no recordable indications.
006430     Inlet Manway Nuts; VT-1   VT-1, MT 8c UT, no recordable 16  Total.            UT     indications acceptable.
UT;no recordable indications, UT, Geom: 2 indications, 1 upstream&.1 downstream-acceptable..
MT
014200 Pipe to Pipe Weld;UT C PT PT;no recordable indications.
 
UT;no recordable indications, UT, Geom: 2 indications, 1 upstream&, 1 downstream-acceptable.
C Summary                         NDE Exam             Results 006435   Inlet Manway Studs; VT-1 VT-1,       MT 8c UT, no   recordable 16 Total.            UT  ,indications         acceptable.
r w 014500 Pipe to Nozzle Weld;D UT.PT PT 8c UT;no recordable indications.
MT Summary                         NDE Exam             Results 009200   Component Support     VT-3 VT-3, no recordable         indications Hanger; RHE-8-PR1             acceptable.
UT Geom upstream-acceptable.
        ~tt 4                  R '
5 2tt Summary NDE Exam Results 023000 Tee to Pipe Weld;PT 9 PT;no recordable indications acceptable.
ll           'B Summary                         NDE Exam             Results 014000   Safe End to Pipe     UT   PT; no recordable indications.
Qi ,f I Summary NDE Exam Results 025200 Pipe to Elbow Weld;PT 20 PT;no recordable indications acceptable.
Weld'                  PT  UT; no recordable indications, UT,Geom: 2 indications upstream acceptable.
026000 Pipe to Reducer Weld;27 PT RT PT;no recordable indications (to verify removal of surface type Geom, indication.)
Pipe to Pipe Weld;        PT; no recordable indications.
RT;no recordable indications, Insig., intermittent IUC, suck-up, tungsten spot Bc spot pores acceptable.
a.
Summary~i~10-I2-5 NDE Exam Results 034200 Elbow to Pipe Weld;GSW-2 UT PT PT 8c UT;no recordable indications.
014100                          UT B                    PT  UT; no recordable indications, UT, Geom: 2 indications, 1 upstream       &. 1 downstream-acceptable..
UT Geom: upstream inside surface acceptable.
014200   Pipe to Pipe Weld;   UT   PT; no recordable indications.
Summary~L'e: 0-S-2501-B NDE Exam Results 034530 Hydraulic Snubber VT-3 Support;SIU-3 VT-3;no recordable indications, PSA-10 setting of 3 1/4" at a temperature of 57 deg.F.-acceptable.
C                      PT  UT; no recordable indications, UT, Geom: 2 indications, 1 upstream       &, 1 downstream acceptable.
036100 Elbow to Nozzle Weld;K UT PT PT;Insig: 1/4" long arc strike-acceptable per Section XI table 3514-2.UT;no recordable indications
r   w 014500   Pipe to Nozzle         UT   PT   8c   UT; no   recordable Weld;  D              .PT  indications.         UT Geom upstream         acceptable.
-acceptable.
5 2tt Summary                         NDE Exam             Results 023000   Tee to Pipe Weld;     PT   PT; no recordable indications 9                          acceptable.
7, 9"~ow L>~~~@Ryi~~0 Summary/036400 Rigid Hanger, Integral Attachment; RHU-22-3-NDE Exam PT Results PT;Rej,, slag inclusions at NE&SE Lug plates in crotch area.NCR 90-163 generated, use-as-is per Engineering evaluation-acceptable.  
 
,gS Summary NDE Exam Results 036500 Rigid Hanger Support;RHU-22 VT-3;no recordable indications
Qi
-acceptable.
,f I
8e 4"~w~8~4~~~Sa e~stem: Summary NDE Exam Results 036800 Elbow to Pipe Weld;H UT PT PT 8r, UT;no recordable indications
 
-acceptable.
Summary                         NDE Exam           Results 025200   Pipe to Elbow Weld;   PT   PT; no   recordable indications 20                          acceptable.
9.$"~w~~~~~~~tg'ummary NDE Exam Results 037600 852A Valve to Pipe UT Weld;J PT PT R UT;no recordable indications.
026000   Pipe to Reducer       PT   PT; no   recordable indications Weld; 27              RT  (to verify     removal of surface type Geom, indication.) RT; no recordable indications, Insig.,
UT;Geom., Elbow side, root geometry-acceptable.
intermittent IUC, suck-up, tungsten spot     Bc spot pores acceptable.
10.!&'ummary NDE Exam Results 039600 Pipe to Elbow Weld;ASW-1 PT PT, Rej.;Rough weld&, pores in center line of weld.Reexam.after blending weld-no recordable indications per Sect.XI IWB-3514-2,-acceptable.
          ~i~ 10   - I2- 5 Summary                          NDE Exam           Results 034200   Elbow to Pipe         UT   PT 8c UT; no recordable Weld; GSW-2            PT  indications. UT Geom:
11 2" ROXeM LKULSall Summary l e.NDE Exam Results 041600 Pipe to Elbow Weld;GSW-14 PT Insig~;1/16" Dia.round indication.
upstream inside surface acceptable.
Acceptable per Section XI IWB-3514-2.
          ~L'e:   0 -S -2501-B Summary                          NDE Exam           Results 034530   Hydraulic Snubber     VT-3 VT-3; no recordable Support; SIU-3              indications, PSA-10 setting of 3 1/4" at a temperature     of 57 deg. F. acceptable.
c)>l l.
036100   Elbow to Nozzle       UT   PT; Insig: 1/4" long arc strike Weld; K                PT  -acceptable per Section XI table 3514-2. UT; no recordable indications acceptable.
Summary 042300 Nozzle'to Pipe Weld;1 NDE Exam PT Results PT: no recordable indications acceptable.
7, 9" ~ow L>~~~@     Ryi~~
D w h='UUI Summary NDE Exam Results 043300 Pipe to Elbow Weld;6 PT PT: no recordable indications acceptable.
0 Summary                         NDE Exam          Results
Summary Number 046000 Com onent NDE Exam Rigid Restraint PT Integral Attachment Support;CVU-31 Results PT: no recordable indications acceptable.
/
046020 Rigid Restraint Support;CVU-31 VT-3 VT-3: no recordable indications acceptable.
036400   Rigid Hanger,         PT   PT;   Rej,, slag inclusions at Integral Attachment;        NE & SE Lug plates     in crotch RHU-22                      area. NCR 90-163 generated, use-as-is per Engineering evaluation-acceptable.
Summary al~akJ~-NDE Exam Results 051200 Elbow to Pipe Weld'7 PT PT: no recordable indications acceptable.
,gS Summary                       NDE Exam                     Results 036500     Rigid Hanger                       VT-3; no recordable Support; RHU-22                    indications               acceptable.
I" Alt Summary NDE Exam Results 052525 Anchor Integral PT Attachment Support;CVU-24 PT: no recordable indications acceptable.
8e 4" ~w ~8~4~~     ~Sa                   e     ~stem:
Summary                       NDE Exam                       Results 036800     Elbow to Pipe       UT             PT   8r, UT; no         recordable Weld; H            PT            indications               acceptable.
: 9. $ " ~w ~~~ ~~                                 ~~tg
                                                              'ummary NDE Exam                       Results 037600     852A Valve to Pipe UT             PT R UT; no             recordable Weld; J            PT            indications. UT; Geom.,               Elbow side, root geometry acceptable.
: 10.                     !
                                    &'ummary NDE Exam                       Results 039600     Pipe to Elbow       PT             PT,     Rej.; Rough weld         &, pores in Weld; ASW-1                        center line of weld. Reexam.
after blending weld- no recordable indications per Sect. XI IWB-3514- 2,
                                              -acceptable.
11   2" ROXeM           l     e.
LKULSall Summary                        NDE Exam                       Results 041600     Pipe to Elbow       PT             Insig ~ ; 1/16" Dia. round Weld; GSW-14                      indication. Acceptable per Section XI IWB-3514-2.
 
c)>
l l.
 
Summary                       NDE Exam          Results 042300 Nozzle 'to Pipe       PT   PT: no   recordable indications Weld;  1                  acceptable.
D   w       h='UUI Summary                       NDE Exam         Results 043300 Pipe to Elbow         PT   PT: no   recordable indications Weld;  6                  acceptable.
Summary                       NDE Number Com onent           Exam         Results 046000  Rigid Restraint       PT   PT: no   recordable indications Integral Attachment        acceptable.
Support; CVU-31 046020  Rigid Restraint      VT-3 VT-3: no recordable indications Support;  CVU-31            acceptable.
al~akJ~
Summary                    - NDE Exam         Results 051200 Elbow to Pipe         PT   PT: no   recordable indications Weld'7                    acceptable.
I" Alt Summary                       NDE Exam         Results 052525 Anchor Integral       PT   PT: no recordable indications Attachment Support;        acceptable.
CVU-24
 
C")
C")
Summary NDE Exam Results 052530 Anchor Support: CVU-24 VT-3 VT-3;no recordable indications acceptable.
Summary                     NDE Exam           Results 052530 Anchor Support:     VT-3 VT-3; no recordable       indications CVU-24                      acceptable.
053300 383A Valve to Pipe UT Weld'8 PT PT Sc UT;no recordable indications
053300 383A Valve   to Pipe UT   PT Sc UT; no   recordable Weld'8              PT  indications     acceptable.
-acceptable.
053800 Pipe to Nozzle       PT   PT; no   recordable indications Weld; 43                    acceptable.
053800 Pipe to Nozzle Weld;43 PT PT;no recordable indications acceptable.
w Summary                     NDE Exam           Results 054200 Variable Spring     VT-3 VT-3; Rej. 3/4" rod bent.       NCR Support; CVU-51          90-167 generated.       Reexam.
w Summary NDE Exam Results 054200 Variable Spring Support;CVU-51 VT-3 VT-3;Rej.3/4" rod bent.NCR 90-167 generated.
after repairs, Setting of       61&#xb9; at 65 deg. F.,Support SN: 582
Reexam.after repairs, Setting of 61&#xb9;at 65 deg.F.,Support SN: 582-acceptable.
                                  -acceptable.     Service Induced expanded scope required. See Summary   &#xb9;'s 054300   5, 054900.
Service Induced expanded scope required.See Summary&#xb9;'s 054300 5, 054900.054300 U-Bolt Support;CVU<<50 VT-3 VT-3;no recordable indications acceptable, no degradation of component identified with expanded service induced scope.054300 Variable Spring Support;CVU-5 VT-3 VT-3;no recordable indications acceptable, no degradation of component identified with expanded service induced scope.Setting of 135&#xb9;at 63 deg.F.Berger Patterson Size 3 support.055100 393 Valve to Pipe UT Weld;11 PT PT&UT;no recordable indications
054300 U-Bolt Support;     VT-3 VT-3; no recordable indications CVU<<50                      acceptable,   no degradation of component identified with expanded service induced scope.
-acceptable.
054300 Variable Spring     VT-3 VT-3; no recordable indications Support;  CVU-5              acceptable,   no degradation of component identified with expanded service induced scope.
lt I l S P l 0 15.~Rabat)~~Cl~at~P~u~C~~~We~aw Summary NDE Exam Results 057410 Weld A VT-1 PT VT-1 8c PT;no recordable indications.
Setting of 135&#xb9; at 63 deg. F.
VT-1, Insig;pits from casting process 360 deg.around weld<1/32".Grind marks from prepping-acceptable.
Berger Patterson Size       3 support.
PT, Insig;15 Random rounded indications
055100 393 Valve to Pipe   UT   PT & UT; no   recordable Weld; 11            PT  indications - acceptable.
<1/16" Dia., small scale 1/8 x 1/4 and 4 gouges at weld attachments
 
<1/32" acceptable.
lt I
057420 Weld B VT-1 PT VT-1&.PT;no recordable indications.
l S   P l
VT-1, Insig;pits from casting process 360 deg.around weld<1/32".Grind marks from prepping-acceptable.
0
PT;Insig., casting rounded inclusions 1/8" Dia.;Limitations due to pump supports B-1, B-2&, B-3 over weld for 20" each acceptable.
: 15. ~Rabat)~ ~Cl~at ~P
057430 Weld C VT-1 PT VT-1&PT;no recordable indications.
        ~u   ~C~~ ~We ~               aw Summary                       NDE Exam           Results 057410   Weld A             VT-1 VT-1 8c PT; no recordable PT  indications. VT-1, Insig; pits from casting process 360 deg.
VT-1&PT;Insig., Gouge 1/2 x 1/32 deep by 1/16 wide at 11 1/2" location acceptable.
around weld < 1/32". Grind marks from prepping-acceptable.
Also, 1/2" Dia.rounded indication above gouge with cluster porosity<1/64" each-acceptable.
PT, Insig; 15 Random rounded indications < 1/16" Dia., small scale 1/8 x 1/4 and 4 gouges at weld attachments < 1/32" acceptable.
w Summary NDE Exam h Results 057910 Support 1 ,VT-1 PT VT-1&, PT;no recordable indications.
057420   Weld B           VT-1 VT-1 &. PT; no recordable PT  indications. VT-1, Insig; pits from casting process 360 deg.
VT-1, Insig.;minor pits<1/32" in casting, grind marks from welds ground flush-acceptable.
around weld < 1/32". Grind marks from prepping-acceptable.
PT, Insig.;2 indications each 3/8" long.Indications are underbead cold laps at edge of weld and are not service induced-acceptable.
PT; Insig., casting rounded inclusions 1/8" Dia.;
4e$g Summary NDE Exam Results 057920 Support 2 057930 Support 3 VT-1 PT VT-1 PT VT-1 8c PT;no recordable indications.
Limitations due to pump supports B-1, B-2 &, B-3 over weld for 20" each acceptable.
VT;1, Insig.;under cut<1/32" long acceptable.
057430   Weld C           VT-1 VT-1 &   PT; no recordable PT  indications. VT-1 & PT; Insig.,
PT, Insig.;Linear indication 7/16" long is undercut<1/32" deep, Indication not service induced and acceptable per Section III NB4424(C).
Gouge 1/2 x 1/32 deep by 1/16 wide at 11 1/2" location acceptable.     Also, 1/2" Dia.
VT-1 8c PT;no recordable indications.
rounded indication above gouge with cluster porosity < 1/64" each -acceptable.
VT-1, Insig.;Weld is prepped showing grind marks<1/32" deep-acceptable.
w Summary                     NDE             h Exam           Results 057910   Support 1         ,VT-1 VT-1 &, PT; no recordable PT  indications. VT-1, Insig.;
16.Qeac~o Coa,'~Q~~e: ee W Summary NDE Exam Results 058200 Flywheel, SN: 212-3D19156-G01-02 UT UT;no recordable indications, Top side keyway bore reflections were observed-acceptable.
minor pits < 1/32" in casting, grind marks from welds ground flush -acceptable. PT, Insig.;
17.Va.'I vi~~0~~q VVVv~e Summary NDE Exam w Results 058300 Darling Check Valve 842A VT-1 VT-1;no recordable indications acceptable.
2 indications each 3/8" long.
Summary 10"~Ce<+V~alv NDE Exam Results 058400 Darling Check Valve 842B VT-1 VT-1;no recordable indications acceptable.
Indications are underbead cold laps at edge of weld and are not service induced acceptable.
4 Summary NDE Exam Results 059100 Velan Motor Oper.VT-1 VT-1;no recordable indications Gate Valve 701 bolts inspected in place acceptable.
 
Summary~G~V~v~5)0~bs NDE Exam Results 059200 Velan Motor Oper.UT Gate Valve;720-1 PT Body Weld PT&UT: no recordable indications
4e
-acceptable.
$g
059205 Velan Motor Oper.UT Gate Valve;720-2 PT Body Weld PT&, UT: no recordable indications
 
-acceptable.
Summary                       NDE Exam           Results 057920     Support   2         VT-1 VT-1 8c   PT; no recordable PT  indications. VT;1, Insig.;
059210 ,Velan Motor Oper.VT-3 VT-3;no recordable indications Gate Valve;720 acceptable.
under cut     < 1/32" long acceptable. PT, Insig.; Linear indication 7/16" long is undercut < 1/32" deep, Indication not service induced and acceptable     per Section III NB4424(C).
059300 Velan Motor Oper.VT-1 VT-1, MT&.UT: no recordable Gate Valve;720 indications.
057930    Support  3        VT-1 VT-1  8c   PT; no recordable PT  indications. VT-1, Insig.;
Baseline exam performed in 1989.Nuts and Studs installed in 1990.Summary 6"~Ceca~Vive NDE Exam Results 059600 Velan Check Valve;VT-1 VT-1: no recordable indications, Bolts inspected in place-acceptable.
Weld is prepped showing grind marks   < 1/32" deep acceptable.
Summary Number Com onent 059600 Velan Check Valve;NDE Exam VT-1 Results VT-1: no recordable indications, Bolts inspected in place-acceptable.
: 16. Qeac~o ee Coa,'~Q ~ ~e:         W Summary                       NDE Exam           Results 058200     Flywheel,   SN:   UT  UT; no recordable indications, 212-3D19156-G01-02       Top side keyway bore reflections     were observed acceptable.
V t 1t>I g'I joe~~Vvea Summary NDE Exam Results 060000 Crosby Relief Valve;434 VT-1 VT-1: no recordable indications on 8 1 1/4" Dia.Bolts, 93 1"x8 nuts&, 48 1"x8x7" studs.Rej: 12 1" Dia.Bolts.NCR 90-159 was generated for disposition.
: 17. Va.'I vi~
Examination performed after installation; flange, bonnet studs&replacements acceptable.
          ~0     ~~q   VVVv~e               w Summary                       NDE Exam           Results 058300     Darling   Check     VT-1 VT-1; no recordable indications Valve 842A                acceptable.
060100 Crosby Relief Valve;435 VT-1 VT-1: no recordable indications, 93 1"x8 nuts&48 1"x8x7" studs.Insig: 1 of 1 1/4" Dia.bolts have minor corrosion; 7 bolts, NRI with 8 acceptable.
10" ~Ce<+ V~alv Summary                        NDE Exam           Results 058400     Darling Check       VT-1 VT-1; no recordable indications Valve 842B                acceptable.
Re): 12 1" Dia.bolts with thread damage.NCR 90-159 was generated for disposition.
 
Examination performed after installation; flange, bonnet studs&, replacements-acceptable.
4 Summary                       NDE Exam         Results 059100   Velan Motor Oper. VT-1 VT-1; no recordable indications Gate Valve 701               bolts inspected in place acceptable.
CoK~tQ;~Eely Summary NDE Exam Results 060200 Copes-Vulcan Control Valve;430 VT-1 VT-1: no recordable indications
            ~G   ~V~v ~5)0 ~bs Summary                      NDE Exam         Results 059200   Velan Motor Oper. UT   PT & UT: no    recordable Gate Valve; 720-1   PT   indications     acceptable.
-acceptable.
Body Weld 059205   Velan Motor Oper. UT   PT  &, UT: no  recordable Gate Valve; 720-2   PT   indications      acceptable.
3"~Zalea W Summary H-NDE Exam Results 060600 Velan Motor Oper.VT-1 Gate Valve;515 VT-1;no recordable indications acceptable.  
Body Weld 059210  ,Velan Motor Oper. VT-3 VT-3; no recordable indications Gate Valve; 720             acceptable.
(l wh, I  
059300   Velan Motor Oper. VT-1 VT-1,   MT &. UT: no recordable Gate Valve; 720           indications. Baseline exam performed in 1989. Nuts and Studs installed in 1990.
~i~t+o.~Va ve Summary NDE Exam Results 060200 Copes-Vulcan Control Valve;200A VT-1 VT-1: Rej: heavy corrosion on nuts, WO 9021545 was generated to clean nuts for examination in accordance with A-1407 Procedure.
6" ~Ceca ~Vive Summary                      NDE Exam         Results 059600   Velan Check Valve;   VT-1 VT-1: no recordable indications, Bolts inspected in place acceptable.
No recordable indications
Summary                       NDE Number   Com   onent         Exam          Results 059600   Velan Check Valve;   VT-1 VT-1: no recordable indications, Bolts inspected in place acceptable.
&, no material degradation observed-acceptable.
 
060900 Copes-Vulcan Control Valve;200B VT-1 VT-1: no recordable indications
V t
-acceptable.
1t>
070000 Copes-Vulcan Control Valve;202 VT-1 VT-1: Rej: Boron deposits on top of gl&.g7 nuts and, between nuts&, bolts.WO 9021545 was generated to clean deposit areas for examination in accordance with A-1407 Procedure.
I g 'I
No recordable indications
 
&no material degradation observed-acceptable.
joe~   ~Vvea Summary                       NDE Exam         Results 060000   Crosby Relief       VT-1 VT-1: no recordable Valve; 434                indications on 8 1 1/4" Dia.
B.CLASS 2 COMPONENTS:
Bolts, 93 1"x8 nuts &, 48 1"x8x7" studs. Rej: 12 1" Dia.
1.o'La Summary NDE Exam Results 072240 7/8" Diameter Bolts UT VT-1 MT VT-1: no recordable indications.
Bolts. NCR 90-159 was generated for disposition.
Insig: slight rust on all bolting.All studs were double nutted top&bottom.One stud over V204A had 1 nut on bottom due to lack of space-acceptable.
Examination performed after installation; flange, bonnet studs & replacements acceptable.
MT: required when bolts are removed, bolting not removed.UT: no recordable indications, 20 bolts were examined from top&bottom-acceptable.
060100   Crosby Relief       VT-1 VT-1: no recordable Valve; 435                indications, 93 1"x8 nuts & 48 1"x8x7" studs. Insig: 1 of 1 1/4" Dia. bolts have minor corrosion; 7 bolts, NRI with 8 acceptable. Re): 12 1" Dia.
i<l%b Summary NDE Exam Results 073170 Support Leg&#xb9;3;S3 VT-3 VT-3: no recordable indications.
bolts with thread damage. NCR 90-159 was generated   for disposition. Examination performed after installation; flange, bonnet studs &,
Insig: paint on weld-acceptable.
replacements -acceptable.
073400 Support Leg&#xb9;3;PT Integral Attachment
CoK~tQ; ~Eely Summary                       NDE Exam         Results 060200   Copes-Vulcan         VT-1 VT-1: no recordable Control Valve;            indications   acceptable.
'eld, S3 PT: no recordable indications.
430 3" ~   Zalea                   W H
Insig: Weld spatter on weld, nonrelevant indication acceptable.
Summary                       NDE Exam         Results 060600   Velan Motor Oper. VT-1 VT-1; no recordable indications Gate Valve; 515            acceptable.
3.Pg~~o~o~~Flter:~Wl~e Summary NDE Exam Results 073170 Support Leg&#xb9;3;PT Integral Attachment Weld, L3 PT: no recordable indications acceptable.
(l wh, I
074760 Support Leg&#xb9;3;L3 VT-3 VT-3: no recordable indications
 
-acceptable.
          ~i~t+o. ~Va ve Summary                       NDE Exam         Results 060200   Copes-Vulcan         VT-1 VT-1: Rej: heavy corrosion Control Valve;            on nuts, WO 9021545 was 200A                      generated to clean nuts for examination in accordance with A-1407 Procedure. No recordable indications &, no material degradation observed acceptable.
I IL-2 2 Summary 075800 Pipe to Elbow Weld;2 NDE Exam UT PT Results PT 83 UT;no recordable indications
060900   Copes-Vulcan         VT-1 VT-1: no recordable Control Valve;            indications - acceptable.
-acceptable.
200B 070000   Copes-Vulcan         VT-1 VT-1: Rej: Boron deposits Control Valve;            on top of gl &. g7 nuts and, 202                      between nuts &, bolts. WO 9021545 was generated to clean deposit areas for examination in accordance with A-1407 Procedure. No recordable indications   & no material degradation observed acceptable.
5.~Se~We~gc~cC Summary NDE Exam IL Results 078630 Support Leg&#xb9;2;Welded Support, 2 VT-3 VT-3;no recordable indications.
B. CLASS 2 COMPONENTS:
Insig;4 pinholes 1/64", light undercut<1/16" and peening marks-acceptable.
: 1. o
i F'),I Summary NDE Exam Results 074760 Support Leg 42;PT Integral Attachment Weld, 2 PT: no recordable indications.
                                        'La Summary                       NDE Exam         Results 072240   7/8" Diameter       UT   VT-1: no recordable Bolts                VT-1 indications. Insig: slight MT  rust on all bolting. All studs were double nutted top   &
Insig;3 scattered pin holes 1/32" Dia.-acceptable.
bottom. One stud over V204A had 1 nut on bottom due to lack of space -acceptable. MT:
6.~St~@~oo Summary NDE Exam Results 080400 Anchor Support in Pen.401 Outside Containment; PS-A VT-3 MT VT-3;Rej, Lack of thread engagement.
required when bolts are removed, bolting not removed.
NCR 90-186 was generated.
UT: no recordable indications, 20 bolts were examined from top
Engineering disposition of use-as-is was made.MT;Insig, 3/4"xl"x1/2" circular indication with scabs from fabrication
                                  & bottom -acceptable.
-acceptable.
i<
080450 Anchor Support in Pen.401 Inside Containment; PS-B VT-3 MT VT-3;no recordable indication Insig;intermittent arc strikes 360 deg.<1/32"-acceptable.
l
MT;no recordable indications, made.MT;Insig, 3/4"x1"xl/2" 080600 Pipe to Elbow Weld;D RT MT VT-1 VT-1, MT 8c RT;Examined as High Energy Weld, see Summary No.200005 for 1990 results.083200 6" Branch Conn.Weld'3-BC-3 RT VT-1 MT VT-1;no recordable indication Insig: various arc strikes, intermittent undercut&, light rust-acceptable.
%b
MT;Insig, areas of arc strikes acceptable.
 
RT;Other, weld configuration not conducive for RT examination.
Summary                             NDE Exam         Results 073170     Support Leg &#xb9;3;           VT-3 VT-3: no recordable S3                            indications. Insig: paint     on weld   acceptable.
083300 6" Branch Conn.Weld;G3-BC-4 RT VT-1 MT VT-1;no recordable indication Insig: various arc strikes, intermittent undercut-acceptable.
073400     Support Leg &#xb9;3;           PT   PT: no   recordable indications.
MT;no recordable indications in areas of arc strikes-acceptable.
Integral Attachment            Insig:   Weld spatter on weld,
RT;Other, weld configuration not conducive for RT examination.
        'eld,        S3                nonrelevant indication acceptable.
1" P tl cled~*y 8 Summary NDE Exam Results 083860 Bolting (<2")G2-BC-2-B-BT VT-1 MT UT VT-1;no recordable indications on 12, 1"x7 1/4" studs-acceptable.
: 3. Pg~~o           ~o~   ~Flter:
MT;MT not performed, only when studs are removed.UT;no recordable indications, scanned from top side only-acceptable.
        ~Wl~e Summary                             NDE Exam         Results 073170     Support Leg &#xb9;3;           PT   PT: no   recordable indications Integral Attachment              acceptable.
Summary S-00-NDE Exam ILJIQS Results 086800 Mechanical Snubber Support, MSU-15 VT-3 VT-3;no recordable indications SN 7476, North setting=3" South-3 1/4" at a Temp.of 53 deg.F,-acceptable.
Weld, L3 074760     Support Leg &#xb9;3;           VT-3 VT-3: no recordable L3                            indications     acceptable.
Insig;snubber can not be rotated by hand-acceptable.
I       IL
086805 Mechanical Snubber MT Integral Attachment Weld, MSU-15 MT: Insig;intermittent EUC on both North 8r.South snubber that is<1/32" 360 deg.around pipe side-acceptable.
                          -2 2 Summary                             NDE Exam          Results 075800     Pipe to Elbow             UT   PT 83 UT; no recordable Weld;      2            PT  indications     acceptable.
087600 Guide Support;MSU-24 088100 Variable Spring Support;MSU-28 VT-3 VT-3 VT-3: no recordable indications acceptable.
: 5. ~Se
VT-3;no recordable indications acceptable.
        ~We   ~gc~cC                             IL Summary                             NDE Exam         Results 078630     Support Leg &#xb9;2;           VT-3 VT-3; no recordable Welded Support,      2        indications. Insig;     4 pinholes 1/64", light undercut < 1/16" and peening marks acceptable.
Insig;rivet missing on ID Tag.Setting of 3 1/4 with load of 108524 at 47 deg.F., Berger patterson VS-1 support-acceptable.
i F')
Summary'89300 6" Branch Conn.Weld;L2-BC-1 NDE Exam RT VT-1 MT Results VT-1;no recordable indication Insig: Light rust 360 deg.on weld, intermittent weld spatter Sc undercut<1/32" deep-acceptable.
  ,I
MT;no recordable indications-acceptable.
 
RT;Other, weld configuration not conducive for RT examinations l l'A
Summary                       NDE Exam         Results 074760   Support Leg 42;       PT   PT: no recordable indications.
-'*Summary NDE Exam Results 093500 Variable Spring Support;FWU-1 VT-3;Rej.Top nut, not in full thread engagement.
Integral Attachment        Insig; 3 scattered pin holes Weld,  2                  1/32" Dia. acceptable.
NCR 90-173 was generated for Engineering evaluation.
: 6. ~   St~@ ~oo Summary                       NDE Exam         Results 080400   Anchor Support in     VT-3 VT-3; Rej, Lack of thread Pen. 401 Outside      MT  engagement. NCR 90-186 was Containment; PS-A          generated. Engineering disposition of use-as-is was made. MT; Insig, 3/4"xl"x1/2" circular indication   with scabs from fabrication acceptable.
Condition previous addressed on NCR G83-132, use-as-is-acceptable.
080450   Anchor Support   in   VT-3 VT-3; no recordable indication Pen. 401 Inside      MT  Insig; intermittent arc strikes Containment; PS-B          360 deg. < 1/32" -acceptable.
093505 Variable Spring MT Integral Attachment Weld, FWU-1 MT;no recordable indications accept'able.
MT; no recordable indications, made. MT; Insig, 3/4"x1"xl/2" 080600   Pipe to Elbow         RT   VT-1, MT 8c RT; Examined as High Weld;  D              MT  Energy Weld, see Summary No.
094300 Elbow to Nozzle Weld;EE RT MT VT-1 VT-1&, MT;no recordable indications
VT-1 200005 for 1990 results.
-acceptable.
083200   6" Branch Conn.       RT   VT-1; no recordable   indication Weld'3-BC-3          VT-1 Insig: various arc strikes, MT  intermittent undercut &, light rust acceptable. MT; Insig, areas of arc strikes acceptable. RT; Other, weld configuration not conducive for RT examination.
RT;Insig, Various porosity, no apparent change since last examination on 4/7/89.aw Summary NDE Exam Results 095400 Mechanical Snubber VT-3 Support, FWU-47 VT-3;no recordable indications'ubber Boot covering snubber is ripped.Acceptable for ISI examination, Trouble Card written for boot covering.096800 Rigid Restraint Support;FWU-56 VT-3 VT-3: no recordable indications acceptable.
083300   6" Branch Conn.       RT  VT-1; no recordable  indication Weld; G3-BC-4         VT-1 Insig: various arc strikes, MT   intermittent undercut acceptable. MT; no recordable indications in areas of arc strikes -acceptable. RT; Other, weld configuration not conducive for RT examination.
097200 Pipe to Elbow Weld'2 RT MT VT-1 UT PT UTTK VT-1&, MT;Weld prep for I-98 UT, no recordable indications.
1" P tl cled~
PT;(Aug.exam)no recordable indications.
y 8
UTTK;(Aug.
 
exam)acceptable.
Summary                           NDE Exam           Results 083860         Bolting (< 2")   VT-1 VT-1; no recordable G2-BC-2-B-BT       MT   indications on 12, 1"x7 1/4" UT    studs acceptable. MT; MT not performed, only when studs are removed. UT; no recordable indications, scanned from top side only -acceptable.
UT;(I-98), no Recordable indications.
S              ILJIQS Summary                           NDE Exam           Results 086800         Mechanical Snubber VT-3 VT-3; no recordable indications Support, MSU-15          SN   7476, North setting = 3" South 3 1/4" at a Temp. of 53 deg. F, -acceptable.           Insig; snubber can not be rotated by hand -acceptable.
UT;(I-98), Geom;ID configuration.
086805         Mechanical Snubber MT  MT:  Insig; intermittent     EUC on Integral Attachment      both North South snubber that 8r.
UT performed in lieu of RT.
Weld, MSU-15            is < 1/32" 360 deg. around pipe side -acceptable.
087600         Guide Support;     VT-3 VT-3: no recordable indications MSU-24                      acceptable.
088100        Variable Spring    VT-3 VT-3; no recordable indications Support;  MSU-28            acceptable. Insig; rivet missing on ID Tag. Setting of 3 1/4 with load of 108524 at 47 deg. F., Berger patterson VS-1 support-acceptable.
Summary                           NDE Exam          Results
        '89300 6" Branch Conn. RT  VT-1; no recordable      indication Weld; L2-BC-1       VT-1 Insig: Light rust 360 deg. on MT  weld, intermittent weld spatter Sc undercut   <   1/32" deep acceptable.       MT; no recordable indications -acceptable. RT; Other, weld configuration not conducive for RT examinations


Summary NDE Exam Results 099900 Elbow to Nozzle Weld;BB RT MT VT-1 UT VT-1 8c MT;no recordable indications
l l 'A
-acceptable.
 
RT;Insig, Various porosity>slag&, suck up.No apparent change since last examination on 3/27/89.UT;no downstream examination, indications were inclusions
Summary                     NDE Exam             Results 093500  Variable Spring              VT-3; Rej. Top nut, not in full Support;  FWU-1              thread engagement. NCR 90-173 was generated for Engineering evaluation. Condition previous addressed on NCR G83-132, use-as-is -acceptable.
&, ID surface geometry-acceptable.
093505  Variable Spring      MT      MT; no  recordable indications Integral Attachment            accept'able.
9.~ow+~si~c~e~t I"~Summary NDE Exam Results 100310 2" Branch Weld;5M PT PT;no recordable indications acceptable.
Weld, FWU-1 094300  Elbow to Nozzle     RT      VT-1  &, MT; no  recordable Weld; EE            MT      indications  acceptable.
100325 Guide Support;SIU-109 VT-3 VT-3: no recordable indications acceptable.
VT-1    RT; Insig, Various porosity, no apparent    change since last examination on 4/7/89.
White powder residue from installation.
aw Summary                      NDE Exam            Results 095400  Mechanical Snubber  VT-3    VT-3; no recordable Support, FWU-47                      Boot covering snubber indications'ubber is ripped. Acceptable for ISI examination, Trouble Card written for boot covering.
100925 Guide Support;SIU-108 VT-3: Insig, insulation residue resulting in light corrosion-acceptable.
096800  Rigid Restraint      VT-3    VT-3: no recordable indications Support; FWU-56                acceptable.
Rej;Loose micarta block identified.
097200  Pipe to Elbow        RT     VT-1  &, MT; Weld  prep                  for I-98 Weld'2              MT      UT, no  recordable indications.
NCR 90-160 was generated.
VT-1   PT;(Aug. exam) no recordable UT      indications. UTTK;(Aug. exam)
Engineering evaluation provided use-as-is status.I E I'Summary NDE Exam Results 106050 Rigid Support;SIU-103 VT-3 VT-3: no recordable indications
PT      acceptable. UT; (I-98), no UTTK    Recordable indications. UT; (I-98), Geom; ID configuration. UT performed in lieu of RT.
-acceptable.  
 
Summary                          NDE Exam              Results 099900    Elbow to Nozzle      RT    VT-1   8c MT; no recordable Weld; BB              MT    indications acceptable.
VT-1  RT; Insig, Various porosity>
UT    slag   &, suck up. No apparent change since     last examination on   3/27/89. UT; no downstream examination, indications were inclusions &, ID surface geometry acceptable.
: 9. ~ow +~si~   c~e~t   I     "   ~
Summary                         NDE Exam             Results 100310     2" Branch Weld;       PT     PT; no     recordable indications 5M                              acceptable.
100325     Guide Support;       VT-3   VT-3: no recordable indications SIU-109                        acceptable.     White powder residue from installation.
100925     Guide Support;               VT-3:     Insig, insulation residue SIU-108                      resulting in light corrosion acceptable.       Rej; Loose micarta block identified. NCR 90-160 was generated.       Engineering evaluation provided use-as-is status.
I   E I'
Summary                         NDE Exam             Results 106050     Rigid Support;       VT-3   VT-3: no recordable indications SIU-103                        acceptable.
(
(
Summary NDE Exam Results 110300 Variable Spring Support;RHU-78 VT-3 VT-3;no recordable indications acceptable.
Summary                           NDE Exam                   Results 110300     Variable Spring         VT-3         VT-3; no recordable indications Support;  RHU-78                        acceptable. Setting of 7/8" equates to a load of 644 4's at 61 deg. F..
Setting of 7/8" equates to a load of 644 4's at 61 deg.F..Summary NDE Exam e~Stem:: iLJ-Results 110900 Pipe to Elbow Weld;1A PT UT PT 80 UT;no recordable indications
e   ~Stem:
-acceptable.
: iLJ Summary                            NDE Exam                  Results 110900     Pipe to Elbow           PT           PT 80 UT; no recordable Weld; 1A                UT            indications     acceptable.
II'LJR raw'3~Resi~dg,~a Qe@~v,~S~t~n~Summary 126400 Pipe to Tee Weld;6 NDE Exam PT UT Results PT 80 UT;no recordable indications
        ~ Resi~dg, ~a   Qe@~v, ~S~t~n~
-acceptable.
II raw'3
14.~R~~~geea.Eeeoval,~i~erg: P IJ Summary NDE Exam Results 129900 Tee to Pipe Weld;1 PT UT PT 80 UT;no recordable indications
                                                      'LJR Summary                            NDE Exam                  Results 126400     Pipe to Tee             PT           PT 80 UT; no recordable Weld;  6                UT            indications     acceptable.
-acceptable.  
: 14. ~R~~~
~+I to 15.~Resid a Heat~Remove~Sstem'-20 Summary NDE Exam Results 130300 Pipe to Pipe Weld;1 130550 2" Branch Weld;3A PT UT PT PT;Rej;initial exam indicated linear indications.
P geea. Eeeoval, ~i~erg:
PT;reexam indicated that the linear marks were created by mechanical means, use-as-is by Materials Engineering
IJ Summary                           NDE Exam                   Results 129900     Tee to Pipe           PT           PT 80 UT; no recordable Weld;  1                UT            indications - acceptable.
-acceptable.
~+
UT;no recordable indications acceptable.
I to
PT;no recordable indications acceptable.
: 15. ~Resid a   Heat         ~Remove
16.~Raid al Heat~emova~Sst m: Summary NDE Exam Results 133100 Elbow to Flange'Weld; 24 PT UT PT 85 UT;no recordable indications
                                            ~Sstem'-20 Summary                                   NDE Exam             Results 130300     Pipe to Pipe                   PT       PT; Rej;   initial exam indicated Weld;  1                        UT        linear indications. PT; reexam indicated that the linear marks were created by mechanical means, use-as-is     by Materials Engineering - acceptable. UT; no recordable indications acceptable.
-acceptable.
130550    2" Branch Weld;                PT        PT; no recordable indications 3A                                          acceptable.
17.~Res d al~t removal~Sstem: ILRII Summary 133900 Rigid Restraint Support;RHU-28 NDE Exam VT-3 Results VT-3: no recordable indications acceptable.
: 16. ~Raid   al Heat ~emova             ~Sst m:
133910 Rigid Restraint PT Integral Attachment RHU-28 PT: no recordable indications paint removed-acceptable.
Summary                                   NDE Exam             Results 133100     Elbow to                       PT       PT 85 UT; no recordable 24 Flange'Weld; UT        indications    acceptable.
Summary 136000 Elbow to Tee Weld;17 NDE Exam PT UT Results PT&, UT;no recordable indications
: 17. ~Res d al ~t removal             ~Sstem:
-acceptable.  
ILRII Summary                                   NDE Exam              Results 133900   Rigid Restraint                 VT-3     VT-3: no recordable indications Support;    RHU-28                          acceptable.
-1 yl 18.iiesidu~iiSS2~eoval~St~m: ILs Summary NDE Exam Results 140000 Rigid Hanger;RHU-383 VT-3 VT-3: no recordable indications acceptable, 19.~Res'd a~a gem<~vit.~Ss~tnu C-C-60 raw'iLm Summary 144150 2" Branch Weld;19A NDE Exam PT Results PT;no recordable indications Limitations; Hanger clamp 1/4" from toe of weld-acceptable.
133910   Rigid Restraint                 PT       PT: no   recordable indications Integral Attachment                        paint removed acceptable.
20.Lest~a~Hea~Re i~vs.~Ss em'ummary NDE Exam Results 154250 Rigid Hanger Support;RHU-58 VT-3 VT-3: no recordable indications acceptable.
RHU-28 Summary                                   NDE Exam              Results 136000    Elbow to Tee                     PT       PT &, UT; no recordable Weld; 17                        UT      indications     acceptable.
154255 Rigid Hanger PT Integral Attachment RHU-58 PT: no recordable indications
-1 yl
-paint removed-acceptable.
: 18. iiesidu~     iiSS2 ~eoval ~St~m:
154700 Elbow to Pipe Weld;1M FT UT PT&, UT;no recordable indications
ILs Summary                               NDE Exam                     Results 140000     Rigid Hanger;               VT-3             VT-3: no recordable indications RHU-383                                        acceptable,
-acceptable.
: 19. ~Res'd a     ~a     gem<~vit. ~Ss~tnu C- C-60               raw'               iLm Summary                               NDE Exam                      Results 144150     2" Branch Weld;             PT               PT; no   recordable indications 19A                                          Limitations; Hanger clamp 1/4" from toe of weld acceptable.
21.~es<iUt1~He t~Remov~Si~SL su Summary hfDE Exam Results 158500 Nozzle to Elbow Weld;1 PT UT PT L UT;no recordable indications
: 20. Lest~a       ~Hea   ~Re i~vs . ~Ss em'ummary NDE Exam                     Results 154250   Rigid Hanger                 VT-3             VT-3: no recordable indications Support;    RHU-58                            acceptable.
-acceptable.
154255   Rigid Hanger                 PT               PT: no   recordable indications Integral Attachment                            paint removed acceptable.
Pp  
RHU-58 154700   Elbow to Pipe               FT               PT &, UT; no recordable Weld; 1M                    UT              indications     acceptable.
~Lin 10-D aw'ummary NDE Exam Results 159100 Rigid Support RHU-101 VT-3 VT-3:no recordable indications.
: 21. ~es   < iUt1 ~He t ~Remov     ~Si~SL su Summary                               hfDE Exam                     Results 158500   Nozzle to Elbow             PT               PT L UT; no   recordable Weld;    1                  UT              indications     acceptable.
Insig.Spot of weld at 0" 8L 4" on 10" Elbow, weld deposit-no linear indications-acceptable.
Pp
No ID Tag.Additional Exam after NCR 90-091 for RHU-129 Service Induced Degradation.
        ~Lin   10-               D aw'ummary NDE Exam                     Results 159100   Rigid Support         VT-3           VT-3:no recordable indications.
No Service Induced Degradation found with expanded exam scope.159105 Rigid Support VT-3 Integral Attachment Weld, RHU-101 VT-3:no recordable indications.
RHU-101                              Insig. Spot of weld at 0" 8L 4" on 10" Elbow, weld deposit-no linear indications -acceptable.
Insig, Spot of weld at 0"&, 4" on 10" Elbow, weld deposit-no linear indications-acceptable, No ID Tag.Additional Exam after NCR 90-091 for RHU-129 Service Induced Degradation, No Service Induced Degradation found with expanded exam scope.159450 2" Branch Weld, A4A PT PT: no recordable indications acceptable, 23.~o+~~re~a~et I 8 hixn'Summary NDE Exam Results 159900 Variable Spring Support, RHU-129 VT-3 VT-'3: Service Induced Reject;Rod in spring can is l'ocked.Space in front of can is 1/2", Rod touches rear of can.NCR 90-091 was generated for Engineering disposition.
No   ID Tag. Additional Exam after NCR 90-091 for RHU-129 Service Induced Degradation.
Repairs performed with reexamination acceptable-no recordable indications.
No   Service Induced Degradation found with expanded exam scope.
Setting of 6614 at a Temp.of 69 deg.F.for size 7 acceptable.
159105   Rigid Support         VT-3           VT-3:no recordable indications.
See Summary No.'-s 159100&160400 for expanded scope results.PT 159901 Variable Spring Integral Attachment Weld, RHU-129-20-PT: no recordable indications.
Integral Attachment                  Insig, Spot of weld at 0" &, 4" Weld, RHU-101                        on 10" Elbow, weld deposit-no linear indications -acceptable, No   ID Tag. Additional Exam after NCR 90-091 for RHU-129 Service Induced Degradation, No   Service Induced Degradation found with expanded exam scope.
acceptable.
159450   2" Branch Weld,       PT             PT: no   recordable indications A4A                                    acceptable,
1 Jg lg 24.~Lw~re sure~Sa et Summary NDE Exam Results 160400 Variable Spring Support, RHU-130 VT-3 VT-3: no recordable indications-additional exam after NCR 90-091 for RHU-129 Service Induced Reject.No Service Induced Degradation found.Setting of 482&#xb9;at 69 deg.F.-acceptable.-S-3 Summary NDE Exam Results 160550-Rigid Support RHU-126 VT-3 VT-3: Reject-Support to elbow not welded all around.Missing 3" to 3 1/2" of weld on upper outmost radius.NCR 90-164 was generated.
: 23. ~o   +~~re   ~a~et   I                   8 hixn' Summary                         NDE Exam                     Results 159900   Variable Spring       VT-3           VT-'3: Service Induced Reject; Support, RHU-129                    Rod in spring can is l'ocked.
Engineering disposition and evaluation indicated that the existing weld is adequate and should be used as is-acceptable.
Space in front of can is 1/2",
Ih!''t!e Summary NDE Exam Results 161350 Rigid Restraint Support,-SIU-73 161390 Variable Spring Support, SIU-72 161391 Variable Spring Integral Attachment Weld, SIU-72 VT-3 VT-3 PT VT-3: no recordable indications Insig, grease fitting painted over, Restraint will not swivel back and forth-acceptable.
Rod   touches rear of can. NCR 90-091 was generated     for Engineering disposition.
VT-3: no recordable indications settings were taken at a"Temp.of 77 deg.F.of 5/8" equating to 250&#xb9;-acceptable.
Repairs performed with reexamination acceptable     -no recordable indications.
PT: no recordable indications paint removed from weld acceptable.
Setting of   6614 at a Temp. of 69   deg. F. for size 7 acceptable.     See Summary No.'-s 159100 & 160400 for expanded scope results.
A$Jgl F"''
159901   Variable Spring     PT              PT: no recordable indications.
Summary~Li e: A-S-0 NDE Exam Results 162090 Tee to 3/4" Reducer Weld, 28 PT PT: no recordable indications acceptable.
Integral Attachment                    acceptable.
162210 Rigid Restraint Support, SIU-29 VT-3 VT-3: no recordable indications acceptable.
Weld, RHU-129 1
Summary idee:-SI-5 NDE Exam Results 162740 Pipe to Elbow Weld'6 PT UT PT R UT;no recordable indications
Jg lg
-acceptable.
: 24. ~Lw ~re sure   ~Sa et Summary                           NDE Exam           Results 160400     Variable Spring       VT-3   VT-3: no recordable   indications Support, RHU-130              -additional exam after NCR 90-091 for RHU-129 Service Induced Reject. No Service Induced Degradation found. Setting of 482&#xb9; at 69 deg. F. -acceptable.
fe~e Summary NDE Exam Results 163110 Pipe to Tee Weld;10 PT UT PT 8c UT;no recordable indications
                    -S -3 Summary                           NDE Exam           Results 160550   -
-acceptable.
Rigid Support         VT-3   VT-3: Reject-Support to elbow RHU-126                        not welded all around. Missing 3" to 3 1/2" of weld on upper outmost radius. NCR 90-164 was generated. Engineering disposition and evaluation indicated that the existing weld is adequate and should   be used as is acceptable.
ee p ee.f aJ e r wi Summary 163590 Spring Can Support, SIU-68 NDE exam VT-3 Results VT-3: no recordable indications setting of.7" or 5490 at a Temp, of 78 deg, F.-acceptable.
Ih!''                     t! e Summary                           NDE Exam           Results 161350     Rigid Restraint       VT-3   VT-3: no recordable indications Support, -SIU-73              Insig, grease fitting painted over, Restraint will not swivel back and forth -acceptable.
163591 Spring Can PT Integral Attachment Weld, SIU-68 PT: no recordable indications
161390    Variable Spring        VT-3    VT-3: no recordable indications Support, SIU-72                  settings were taken at a "Temp. of 77 deg. F. of 5/8" equating to 250&#xb9; -acceptable.
-paint removed-acceptable.
161391    Variable Spring        PT      PT: no recordable indications Integral Attachment            paint removed from weld Weld, SIU-72                  acceptable.
I Summary NDE Exam" Results 163640 Rigid Restraint Support, SIU-66 VT-3 VT-3: Reject.Ear on pipe clamp is bent inward.NCR 90-247 was generated for Engineering review.Clamp was replaced, reexamined-acceptable.
A$
Additional Exam performed after NCR 90-107 for SIU-58 that was a Service Induced Reject.No Service Induced Degradation was found with expanded scope acceptable.
Jgl F"'
163650 Guide Support SIU-65 VT-3 VT-3: no recordable indications acceptable.
 
163690 Rigid Support SIU-63 VT-3 VT-3: no recordable indications acceptable.
        ~Li e:   A-S 0 Summary                        NDE Exam             Results 162090   Tee   to 3/4"         PT       PT: no   recordable indications Reducer Weld, 28                  acceptable.
163710 Elbow to Pipe Weld;16 PT UT PT&, UT;no recordable indications
162210   Rigid Restraint       VT-3     VT-3: no recordable     indications Support, SIU-29                  acceptable.
-acceptable.
idee:       -SI- 5 Summary                        NDE Exam             Results 162740   Pipe to Elbow         PT       PT R UT; no   recordable Weld'6                UT      indications     acceptable.
UT, Insig;Geometry downstream acceptable.
fe   ~e Summary                         NDE Exam             Results 163110   Pipe to Tee           PT       PT 8c UT; no recordable Weld;  10            UT      indications     acceptable.
163790 Rigid Restraint Support, SIU-59 VT-3 VT-3: Reject.Identified bushing in upper clamp section while no bushing was in the lower clamp.NCR 90-090 was-generated.
ee     p         ee.f aJ             e r wi Summary                         NDE exam              Results 163590   Spring Can             VT-3   VT-3: no recordable indications Support, SIU-68                setting of .7" or 5490 at a Temp, of 78 deg, F.-acceptable.
Bushing is actually a spacer Ec only required on one bolt per QC.Use-as-is, acceptable.
163591   Spring   Can           PT     PT: no recordable indications Integral Attachment            paint removed- acceptable.
No other recordable indications acceptable.
Weld, SIU-68 I
Additional exam performed after NCR 90-107 for SIU-58 Service Induced Reject.No Degradation found with expanded scope-acceptable.
Summary                   NDE Exam "
163820 Rigid Support SIU-58 VT-3-23-VT-3: Service Induced Reject, Loose nut identified on top while the nut on the bottom tube can be turned by hand.NCR 90-107 was generated for disposition.
Results 163640 Rigid Restraint   VT-3     VT-3: Reject. Ear on pipe clamp Support, SIU-66            is bent inward. NCR 90-247 was generated for Engineering review. Clamp was replaced, reexamined-acceptable.
Nuts were tightened, Reexam after repairs acceptable.
Additional     Exam   performed   after NCR   90-107   for SIU-58 that was a Service Induced Reject.           No Service Induced Degradation was found with expanded scope acceptable.
For Service Induced Code Reject,'xam.
163650 Guide Support     VT-3     VT-3: no recordable indications SIU-65                        acceptable.
scope was expanded.Exams were performed on Summary 0's 163830, 163790 8c 163640.
163690 Rigid Support     VT-3     VT-3: no recordable indications SIU-63                        acceptable.
p Summary NDE Exam.Results 163830 Rigid Restraint Support, SIU-57 VT-3: Additional exam after NCR 90-107 for SIU-58 for Service Induced Reject.No Service Induced Degradation was found-acceptable.
163710 Elbow to Pipe     PT       PT &, UT; no   recordable Weld; 16          UT      indications - acceptable.
31~HiiHh~rsyure~~et Summary 164300 Flange to Pipe Weld;56 NDE Exam PT UT Results PT&, UT;no recordable indications
UT, Insig; Geometry downstream acceptable.
-acceptable.
163790 Rigid Restraint   VT-3     VT-3: Reject. Identified Support, SIU-59            bushing in upper clamp section while no bushing was in the lower clamp. NCR 90-090 was
Summary NDE Exam iLk4 Results 164700 Pipe to Valve 878H Weld'9 PT PT;no recordable indications acceptable.
                                  - generated.       Bushing is actually a spacer Ec only required on one bolt per     QC. Use-as-is, acceptable.       No other recordable indications acceptable.       Additional   exam performed after NCR 90-107 for SIU-58 Service Induced Reject.
33'a'S~a~t~Summary NDE Exam Results 166050 Reducer to Pipe Weld;2 PT UT PT&, UT;no recordable indications
No Degradation found with expanded     scope -acceptable.
-acceptable.
163820 Rigid Support     VT-3     VT-3: Service Induced Reject, SIU-58                      Loose nut identified on top while the nut on the bottom tube can be turned by hand.
UT, Root Geometry  
NCR   90-107 was generated     for disposition.       Nuts were tightened, Reexam after repairs acceptable. For Service Induced Code Reject,'xam.
%l 6-S-30 Summary NDE Exam Results 166840 Rigid Support CSU-33 VT-3 UTTK PT VT-3 Rej., 1 1/2" of weld missing at crotch&arc strike adjacent to the weld.NCR 90-089 was generated.
scope was expanded.         Exams were performed on Summary 0's 163830,     163790 8c 163640.
Arc strike was blended out.UT thickness readings obtained&, Acceptable.
p Summary                       NDE Exam.         Results 163830     Rigid Restraint         VT-3: Additional exam after Support, SIU-57          NCR 90-107 for SIU-58 for Service Induced Reject. No Service Induced Degradation was found -acceptable.
PT&, VT-3 reexam after repairs-acceptable'ngineering evaluation performed on missing weld with a use-as-is determination based on design analysis EWR 2512&, ME 39 Attachment Bl.166842 Rigid Support PT Integral Attachment CSU-33 PT;no recordable indications acceptable.
31 ~ HiiHh ~rsyure ~~et Summary                       NDE Exam          Results 164300     Flange to Pipe     PT   PT &, UT; no recordable Weld; 56          UT    indications     acceptable.
C.CLASS 3 COMPONENTS:
iLk4 Summary                       NDE Exam           Results 164700     Pipe to Valve 878H PT   PT; no   recordable indications Weld'9                      acceptable.
Summary NDE Exam Results 500200 Rigid Support VT-3 Integral Attachment CCU-86 VT-3: no recordable indications acceptable.
33 'a'S~a             ~t~
500205 Rigid Support CCU-86 VT-3 VT-3: no recordable indications Insig;no grout-not required per ME121.Weep hole accepted, general practice when welding a confined component-acceptable.  
Summary                       NDE Exam           Results 166050     Reducer to Pipe   PT   PT &, UT; no recordable Weld; 2            UT    indications     acceptable.
~h 2.Service Water: Summary NDE Exam Results 502080 Rigid Support VT-3 Integral Attachment SWU-212 ,VT-3: no recordable indications Insig.surface rust 8c light scale on weld-acceptable.
UT, Root Geometry
500205 Rigid Support SWU-212 VT-3 VT-3: Rej.4 nuts 1/8" short of full thread engagement.
 
NCR 90-090 was generated for Engineering review.The disposition indicated that the load was in compression and that the condition was use-as-is.-acceptable.
%l 6 -S -30 Summary                     NDE Exam         Results 166840   Rigid Support       VT-3 VT-3   Rej., 1 1/2" of weld CSU-33              UTTK missing at crotch & arc strike PT  adjacent to the weld. NCR 90-089 was generated. Arc strike was blended out. UT thickness readings obtained &, Acceptable.
D aw'ummary NDE Exam Results 502130 Variable Spring Integral Attachment SWU-120 502135 Variable Spring Support, SWU-120 VT-3 VT-3 VT-3: no recordable indications Insig.light rust on weld acceptable.
PT &, VT-3 reexam after repairs
VT-3: no recordable indications at a Temp.of 57 deg.F.the setting was 299&#xb9;'s-acceptable.
                                  -acceptable'ngineering evaluation performed on missing weld with a use-as-is determination based   on design analysis EWR 2512 &, ME 39 Attachment Bl.
MRLIR5=Summary/umber Com onent NDE Exam Results 503620 Rigid Restraint VT-3 Integral Attachment SWU-384 VT-3: no recordable indications Insig.Light rust on lugs, welds R pipe-acceptable.
166842   Rigid Support       PT  PT; no   recordable indications Integral Attachment        acceptable.
503625 Rigid Restraint Support, SWU-384 VT-3 VT-3: no recordable indications pipe clamp insulated acceptable.
CSU-33 C. CLASS 3 COMPONENTS:
t d Summary NDE Exam Results 505000 Guide/Rigid Support VT-3 Integral Attachment AFU-08 VT-3: no recordable indications with paint removed-acceptable.
Summary                     NDE Exam         Results 500200   Rigid Support       VT-3 VT-3: no recordable indications Integral Attachment        acceptable.
505005 Guide/Rigid Support VT-3 AFU-08 VT-3: Rej.Guide does not conform to the component support drawing.Pipe was replaced by steel block with no attachment weld to the pipe.NCR 90-108 was generated for Engineering review.Disposition indicated that no nonconformance occurred due to review of the revised drawing, Revision 1-acceptable.
CCU-86 500205   Rigid Support       VT-3 VT-3: no recordable indications CCU-86                  Insig;   no grout not required per   ME121. Weep hole accepted, general practice when welding a confined component -acceptable.
Summary NDE Exam Results 505270 Variable Spring Support, AFU-104 VT-3: no recordable indications
~h
'Support is a size 9 with a setting of 870 0's taken at a Temp.of 272 deg.F..Support ID4 is N-EG-13312-82-330 acceptable.
: 2. Service Water:
eedwater: Summary NDE Exam Results 507000 Variable Spring Support, AFW-14 VT-3: no recordable indications Support is a Navco type E, Model BE-401 size 0 that had a setting of 604's at a Temp.of 66 deg.F..507090 Guide Support, AFU-221 (was AFW-22)VT-3: no recordable indications Other;New tag for AFU-221 was attached to the support&a new baseline was performed and accepted.  
Summary                       NDE Exam                     Results 502080   Rigid Support       VT-3           ,VT-3: no recordable     indications Integral Attachment                  Insig. surface rust 8c light SWU-212                              scale on weld acceptable.
'Nt/0  
500205   Rigid Support       VT-3             VT-3: Rej. 4 nuts 1/8" short of SWU-212                              full thread engagement. NCR 90-090 was generated for Engineering review. The disposition indicated that the load was in compression and that the condition was use-as-is. acceptable.
-*Summary NDE Exam Results 507180 Variable Spring Support, AFW-30 VT-3 VT-3: Rej.Can setting reading of 580&#xb9;'s conflicted with the 540&#xb9;'s that the Specification allows.NCR 90-185 was generated for Engineering review.The support was reset, reexamined and acceptable.
D aw'ummary NDE Exam                     Results 502130     Variable Spring     VT-3             VT-3: no recordable indications Integral Attachment                  Insig. light rust on weld SWU-120                              acceptable.
Summary NDE Exam Results 507380 Guide, VT-3 integral Attachment AFU-165 (was AFW-88)VT-3: no recordable indications Other, New tag for AFU-165 was attached to the support.A new baseline was performed and accepted.507385 Guide, AFU-165 (was AFW-88)VT-3 VT-3: no recordable indications Other, New tag for AFU-165 was attached to the support.A new baseline was performed and accepted.Summary NDE Exam Results 508000 Variable Spring Support, AFW-3 VT-3 VT-3: no recordable indications acceptable.
502135    Variable Spring      VT-3            VT-3: no recordable indications Support,  SWU-120                    at a Temp. of 57 deg. F. the setting was 299&#xb9;'s -acceptable.
This support is a Navco Type D Size 3 that had a setting of 190&#xb9;'s at a Temp.of 64 deg.F..508090 Hydraulic Snubber Support, AFU-208 (was AFW-13)VT-3 VT-3: Rej.Cold setting should be 3 1/2" was 2 1/8".NCR 90-109 was generated for Engineering review.Disposition indicated that the Gilbert Scales show a 2 1/2" reading.Engineering to revise ME-256 and use-as-is the support to its existing, setting.  
MRLIR5=
'T,~lp Summary 508860 Guide Support Integral Attachment SWU-500 (was SW-88)NDE Exam VT-3 Results VT-3: Rej.Bottom weld on East side has lack of weld at toe.NCR 90-188 was generated for Engineering review.Disposit,ion indicated that repairs will be made.Reexam after repairs indicated insignificant results being that small pinholes 1/16" were found 8L acceptable.
Summary                         NDE
This support, has been upgraded to SWU-500 508863 Guide Support SWU-500 (was SW-88)VT-3 VT-3: Guide was formerly SW-88 and has been upgraded to SWU-500~Examination indicated no recordable indications acceptable.
/umber     Com onent           Exam                     Results 503620     Rigid Restraint     VT-3             VT-3: no recordable indications Integral Attachment                  Insig. Light   rust on lugs, SWU-384                              welds R pipe   acceptable.
D.HIGH ENERGY COMPONENTS:
503625     Rigid Restraint     VT-3             VT-3: no recordable indications Support,  SWU-384                    pipe clamp insulated acceptable.
1.~Min Steam~Loo g~Out ide Containment:
t d
Summary NDE Exam Results 200005 Pipe to Elbow Weld, D VT-1 RT MT VT-1 8L RT: no recordable indications.
 
VT-1: Insig.Gouges from line-up lug (1/32" deep, acceptable.
Summary                     NDE Exam             Results 505000 Guide/Rigid Support VT-3     VT-3: no recordable     indications Integral Attachment          with paint   removed   -acceptable.
MT: Insig, surface scabs acceptable.
AFU-08 505005 Guide/Rigid Support VT-3     VT-3: Rej. Guide does not AFU-08                      conform to the component support drawing. Pipe was replaced by steel block with no attachment weld to the pipe.
RT: Insig.Fine 8C spot porosity, all porosity acceptable per table A-5 NACSI 3/2/82.'00120 Elbow to Pipe Weld, E2 VT-1 RT HT VT-1 MT 8L RT: no recordable indications.
NCR 90-108 was generated for Engineering review.
VT-1: Insig.Intermittent undercut up 8L down stream.An arc strike was also identified and prepped to 1/32"-all acceptable.
Disposition indicated that no nonconformance occurred due to review of the revised drawing, Revision   1 -acceptable.
RT: Insig.Suck-up, fine porosity, slight weld concavity&, minor U/C-all acceptable, tg V~~1 2.~Ma'team~Lao B Outside C ntainment:
Summary                     NDE Exam             Results 505270 Variable Spring             VT-3: no recordable indications Support, AFU-104            'Support is a size 9 with a setting of 870 0's taken at a Temp. of 272 deg.     F.. Support ID4 is N-EG-13312-82-330 acceptable.
Summary NDE Exam a~s Results 200030 Pipe to Elbow Weld, D VT-1 RT MT UT VT-1,MT&, UT: no recordable indications.
eedwater:
VT-1:Insig.
Summary                     NDE Exam             Results 507000 Variable Spring             VT-3: no recordable indications Support, AFW-14              Support is a Navco type E, Model BE-401 size   0 that had a setting of 604's at     a Temp. of 66 deg. F..
Light rust on pipe 8L weld-acceptable.
507090 Guide Support,               VT-3: no recordable indications AFU-221                      Other; New tag for AFU-221 was (was AFW-22)                attached to the support & a new baseline was performed and accepted.
UT performed in lieu of RT.200175 Elbow to Pipe Weld, E VT-1 RT MT UT PT UTTK VT-1&MT: no recordable indications for weld prep.PT: no recordable indications.
Nt
UTTK: initial and final thickness measurements for the weld prep-acceptable.
  /
UT: no recordable indications.
0
UT: Geom, Thickness change, root geometry, counterbore and ID-acceptable., 200180 Elbow to Pipe Weld, J VT-1 RT VT-1: no recordable indications VT-1, Insig, Minor pits<1/32" ,light rust and grind marks from weld prep-acceptable.
 
UT, PT&, MT: no recordable indications-acceptable.
Summary                     NDE Exam         Results 507180 Variable Spring     VT-3 VT-3: Rej. Can setting reading Support, AFW-30          of 580&#xb9;'s conflicted with the 540&#xb9;'s that the Specification allows. NCR 90-185 was generated for Engineering review. The support was reset, reexamined and acceptable.
UTTK: initial and final thickness measurements for weld prep-acceptable.
Summary                     NDE Exam         Results 507380 Guide,               VT-3 VT-3: no recordable indications integral Attachment      Other, New tag for AFU-165 was AFU-165                  attached to the support. A new (was AFW-88)              baseline was performed and accepted.
UT: Geom, rough root acceptable.
507385 Guide,               VT-3 VT-3: no recordable indications AFU-165                  Other, New tag for AFU-165   was (was AFW-88)              attached to the support. A   new baseline was performed and accepted.
UT performed in lieu of RT.I k~ice:-90-1 HE: Summary NDE Exam Results 200070 Pipe to Pipe Weld, AA VT-1 RT MT UT VT-1,MT&, UT: no recordable indications.
Summary                     NDE Exam         Results 508000 Variable Spring     VT-3 VT-3: no recordable indications Support, AFW-3              acceptable. This support is a Navco Type   D Size 3 that had a setting of 190&#xb9;'s at a Temp.
VT-1:Insig.
of 64 deg. F..
Under cut<1/32" deep-acceptable.
508090 Hydraulic Snubber   VT-3 VT-3: Rej. Cold   setting should Support, AFU-208          be 3 1/2" was 2 1/8". NCR 90-(was AFW-13)              109 was generated for Engineering review. Disposition indicated that the Gilbert Scales show a 2 1/2" reading.
UT: Geom.ID counterbore configuration was confirmed by RT.Root Geometry acceptable.
Engineering to revise ME-256 and use-as-is the support to its existing, setting.
'T,
~ lp
 
Summary                         NDE Exam            Results 508860   Guide Support         VT-3   VT-3: Rej. Bottom weld on East Integral Attachment          side has lack of weld at toe.
SWU-500                      NCR 90-188 was generated                   for (was SW-88)                  Engineering review. Disposit,ion indicated that repairs will be made. Reexam after repairs indicated insignificant results being that small pinholes 1/16" were found 8L acceptable.
This support, has been upgraded to SWU-500 508863   Guide Support         VT-3   VT-3: Guide was formerly SW-88 SWU-500                      and has been upgraded to SWU-(was SW-88)                  500 Examination indicated no
                                          ~
recordable indications acceptable.
D. HIGH ENERGY COMPONENTS:
: 1. ~Min Steam ~Loo g ~Out ide Containment:
Summary                         NDE Exam             Results 200005   Pipe to Elbow         VT-1   VT-1   8L RT: no             recordable Weld, D              RT    indications. VT-1: Insig.Gouges MT    from line-up lug ( 1/32" deep, acceptable.                 MT: Insig, surface scabs acceptable. RT: Insig.
Fine   8C spot porosity, all porosity acceptable per table A-5 NACSI 3/2/82.'00120 Elbow to Pipe         VT-1   VT-1   MT 8L RT: no           recordable Weld, E2              RT    indications. VT-1: Insig.
HT    Intermittent undercut up                   8L down   stream. An arc               strike   was also identified and prepped to 1/32" -all acceptable.                   RT:
Insig. Suck-up, fine porosity, slight   weld concavity &, minor U/C   -all   acceptable, tg V
~ ~
1
: 2. ~Ma'team   ~Lao   B Outside C ntainment:
a  ~ s Summary                         NDE Exam           Results 200030   Pipe to Elbow         VT-1   VT-1,MT   &,   UT: no   recordable Weld, D                RT    indications. VT-1:Insig. Light MT    rust on pipe weld-acceptable.
8L UT    UT performed in lieu of RT.
200175   Elbow to Pipe         VT-1   VT-1   & MT: no     recordable Weld, E                RT    indications for weld prep.
MT    PT: no recordable indications.
UT    UTTK:   initial and final PT    thickness measurements for the UTTK  weld prep -acceptable.           UT: no recordable indications. UT:
Geom, Thickness change, root geometry, counterbore and ID acceptable.,
200180   Elbow to Pipe         VT-1   VT-1: no recordable indications Weld, J                RT    VT-1, Insig, Minor pits < 1/32"
                                        ,light rust     and   grind marks from weld prep-acceptable.           UT, PT &, MT: no   recordable indications-acceptable.           UTTK:
initial and final       thickness measurements     for weld prep acceptable.       UT:   Geom, rough root acceptable.         UT performed in lieu of     RT.
I     k
        ~ice:       1                   HE:
Summary                         NDE Exam           Results 200070   Pipe to Pipe           VT-1   VT-1,MT   &,   UT: no   recordable Weld, AA              RT    indications. VT-1:Insig.         Under MT    cut < 1/32" deep-acceptable.
UT    UT: Geom. ID counterbore configuration was confirmed by RT. Root Geometry acceptable.
UT performed in lieu of RT.
UT performed in lieu of RT.
I I~h 1 Summary NDE Exam Results 200410 Pipe to Pipe Weld, V2 VT-1 RT MT UT PT VT-1, PT R UT: no recordable indications.
I I
VT-1:Insig.
~h 1
One pit, undercut was removed when weld was ground flush-acceptable.
 
MT;Insig.All undercut was removed-acceptable.
Summary                     NDE Exam         Results 200410   Pipe to Pipe       VT-1 VT-1,   PT R UT: no     recordable Weld, V2          RT  indications. VT-1:Insig.           One MT  pit,   undercut     was removed when UT  weld was ground       flush PT  acceptable. MT; Insig. All undercut was removed acceptable.       UT; Geom. ID root configuration.       UT performed in lieu of RT.
UT;Geom.ID root configuration.
200425   Pipe to Valve     VT-1 VT-1,   MT   &, UT: no   recordable 3993 Weld, W      RT  indications. VT-1:Insig. Arc MT  strike R undercut 1/16" deep UT  acceptable. UT; Geom. No downstream exam due to valve acceptable. UT performed in lieu of   RT.
UT performed in lieu of RT.200425 Pipe to Valve 3993 Weld, W VT-1 RT MT UT VT-1, MT&, UT: no recordable indications.
2         "     Wld         m   t:
VT-1:Insig.
Summary                     NDE Exam         Results 200080   Elbow to Pipe     VT-1 VT-1,MT   R   RT: no   recordable Weld, F4          RT  indications. RT:Insig. Stringer MT  pass weld contains fine         8c spot porosity. No change since last inspected on 1-26-87 acceptable.
Arc strike R undercut 1/16" deep-acceptable.
200090   Elbow to Pipe     VT-1 VT-1,PT   5,   UT: no   recordable Weld, V            RT  indications. VT-1:Insig. 2 pits MT  1/16" deep, acceptable. MT: no UT  recordable indications on weld PT  prep for UT-acceptable. UT:
UT;Geom.No downstream exam due to valve-acceptable.
Geom. Root     Sc counterbore identified. Ut performed in lieu of   RT.
UT performed in lieu of RT.2"-Wld m t: Summary NDE Exam Results 200080 Elbow to Pipe Weld, F4 VT-1 RT MT VT-1,MT R RT: no recordable indications.
13
RT:Insig.Stringer pass weld contains fine 8c spot porosity.No change since last inspected on 1-26-87 acceptable.
\+
200090 Elbow to Pipe Weld, V VT-1 RT MT UT PT VT-1,PT 5, UT: no recordable indications.
2
VT-1:Insig.
 
2 pits 1/16" deep, acceptable.
Summary                   NDE Exam           Results 200530   Pipe to Pipe   VT-1 VT-1,   MT, PT & UT: no Weld, H2        RT  recordable indications MT  acceptable. VT-1; Insig. Light UT  rust & minor pits < 1/32" PT  acceptable. UT; Geom. ID root geometry acceptable. UT performed in     lieu of RT
MT: no recordable indications on weld prep for UT-acceptable.
'200545   Pipe to Pipe   VT-1 MT: Rej. 1/4" linear indication Weld, J        RT  and arc strikes from MT  fabrication. PT: Rej. Linear UT  pin hole indications. NCR 90-PT  123 generated and repairs made.
UT: Geom.Root Sc counterbore identified.
VT-1, UT & PT: no recordable indications -acceptable. VT-1:
Ut performed in lieu of RT.
Insig. Light rust. UT thickness readings were performed and acceptable.       UT; Geom.,   ID and root configuration -acceptable.       UT performed in lieu of RT, IL't
13\+2 Summary NDE Exam Results 200530 Pipe to Pipe Weld, H2 VT-1 RT MT UT PT VT-1, MT, PT&UT: no recordable indications acceptable.
                                    ~: i=2!
VT-1;Insig.Light rust&minor pits<1/32" acceptable.
Summary                   NDE Exam         'Results 200235   Pipe to Elbow   VT-1 VT-1,MT   & RT: no recordable
UT;Geom.ID root geometry-acceptable.
        , Weld, B        RT  indications. RT:Insig. Weld MT  spatter and spot porosity identified acceptable. No apparent change since last examination on 3-17-82 acceptable.
UT performed in lieu of RT'200545 Pipe to Pipe Weld, J VT-1 RT MT UT PT MT: Rej.1/4" linear indication and arc strikes from fabrication.
Summary                   NDE Exam           Results 200295   Pipe to Elbow   VT-1 VT-1   & MT: no recordable Weld, B        RT  indications'T:Insig       ~ Fine MT  and spot   porosity identified.
PT: Rej.Linear pin hole indications.
NCR 90-123 generated and repairs made.VT-1, UT&PT: no recordable indications-acceptable.
VT-1: Insig.-Light rust.UT thickness readings were performed and acceptable.
UT;Geom., ID and root configuration-acceptable.
UT performed in lieu of RT, IL't~: i=2!Summary NDE Exam'Results 200235 Pipe to Elbow , Weld, B VT-1 RT MT VT-1,MT&RT: no recordable indications.
RT:Insig.Weld spatter and spot porosity identified
-acceptable.
No apparent change since last examination on 3-17-82 acceptable.
Summary NDE Exam Results 200295 Pipe to Elbow Weld, B VT-1 RT MT-32-VT-1&MT: no recordable indications'T:Insig
~Fine and spot porosity identified.
No apparent change since last inspection on 3-19-82.
No apparent change since last inspection on 3-19-82.
L J II C, Summary NDE Exam Results 200340 Pipe to Elbow Weld, D VT-1 RT MT VT-1, RT&, MT: no recordable indications.
L J
RT:Insig.Minor suckup, excessive root bead 8c spot porosity-acceptable.
II C,
VT-1: Insig, undercut (1/32" acceptable.
 
No apparent change since last examination in 1982 acceptable.
Summary                     NDE Exam         Results 200340   Pipe to Elbow       VT-1 VT-1, RT &, MT: no recordable Weld,  D            RT  indications. RT:Insig. Minor MT  suckup, excessive root bead     8c spot porosity acceptable.
IL'Summary NDE Exam Results 201000 Anchor Support, MSU-35 VT-3 MT PT VT-3, PT 8c MT: no recordable indications on areas accessible to examination.
VT-1: Insig, undercut ( 1/32" acceptable. No apparent change since last   examination   in 1982 acceptable.
VT-3;Insig.Grout cracked-acceptable.
IL '
Summary NDE Exam Results 201200 Hydraulic Snubber VT-3 Support, S10 VT-3;No recordable indications acceptable.
Summary                     NDE Exam         Results 201000   Anchor Support,     VT-3 VT-3, PT 8c MT: no recordable MSU-35              MT  indications   on areas accessible PT  to examination. VT-3; Insig.
VT-3;Insig.Light rust on pipe clamp-acceptable.
Grout cracked acceptable.
Snubber SN&#xb9;is 487620.Fluid reading of 1 7/16 was taken when the Temp.was 72 deg.F..-acceptable.
Summary                     NDE Exam         Results 201200   Hydraulic Snubber   VT-3 VT-3; No recordable indications Support, S10            acceptable. VT-3; Insig. Light rust on pipe clamp -acceptable.
Summary NDE Exam Results 201400 Hydraulic Snubber Support, S20 VT-3;No recordable indications acceptable.
Snubber SN&#xb9; is 487620.       Fluid reading of 1 7/16 was taken when the Temp. was 72 deg.
The Snubber is a Grinnell Size 3 type having a SN&#xb9;of 11946.The piston position of 2 3/4" was obtained when the temperature was 72 deg.F.-acceptable.
F..-acceptable.
f'4'>>
Summary                     NDE Exam         Results 201400   Hydraulic Snubber       VT-3; No recordable indications Support, S20            acceptable. The Snubber is a Grinnell Size 3 type having a SN&#xb9; of 11946. The piston position of 2 3/4" was obtained when the temperature was 72 deg. F.-acceptable.
Summary Z gine: 14A-FW-900-1A NDE Exam Kl=Results 201600 Mechanical Snubber Support, FWU-21 VT-3 VT-3;Rej.Insulation tight against snubber 6" away on the clamp side.NCR 90-200 was generated for corrective action.Repairs were performed and the support reexamined-acceptable.
f
The Snubber SNg is F-51035-1 that had a setting of 3 5/32" at a Temp.of 75 deg.F~~Summary NDE Exam HS=Results 201840 Hydraulic Snubber Support, FWU-39 VT-3 VT-3;No recordable indications acceptable.
'4'>>
VT-3;Insig.Light rust-acceptable.
 
The Snubber SNg is 61642 which is a type PSA-35 that had a setting of 3 3/8 at a Temp.of 64 deg.F.-acceptable.
Z gine: 14A-FW-900-1A               Kl=
h 201841 Hydraulic Snubber MT Integral Attachment FWU-39 MT;No recordable indications acceptable.
Summary                      NDE Exam         Results 201600   Mechanical         VT-3 VT-3; Rej. Insulation tight Snubber Support,        against snubber 6" away on the FWU-21                  clamp side. NCR 90-200 was generated for corrective action. Repairs were performed and the support reexamined-acceptable. The Snubber SNg is F-51035-1 that had a setting of 3 5/32" at a Temp. of 75 deg.
Summary 202040 Rigid Support FWU-29 NDE Exam VT-3 M.Results VT-3;No recordable indications acceptable.
F ~ ~
L'>pl JI E.STEAM GENERATOR TUBING: Summary NDE Exam Results 800000 Open Generator Tubes having previous identified degradation
HS=
>20X.ET ET;All previous indications
Summary                       NDE Exam         Results 201840   Hydraulic Snubber   VT-3 VT-3;   No recordable indications Support, FWU-39          acceptable. VT-3; Insig. Light rust acceptable. The Snubber SNg is 61642 which is a type PSA-35 that had a setting of 3 3/8 at a Temp. of 64 deg. F.
>20X were examined to the extent of degradation as a minimum.See the 1990 Eddy Current Examination Report for details.800150 20%Rotating Random Sample on open Generator Tubes.ET ET;20X Random sample of all open unsleeved tubes were examined full length.Tube R3-C39 was programed but not examined full length.See the 1990 Eddy Current Examination Report for details.800200 100K of all Unsleeved Tubes'n open Generator Tubes.ET ET;100X of all open unsleeved tubes were examined to the 41 Tube Support on the Hot Leg.See the 1990 Eddy Current Examination Report for details.800350 20X Rotating ET Random Sample on , each type of Sleeve.ET;20X Random sample of each type of sleeved Generator Tube were examined from sleeve end to sleeve end as a minimum.Sleeved Tube R19-C22 was programed (excess of 20X)but not examined.See,the 1990 Eddy Current Examination Report for details.~-~R'ummary NDE Exam Results 801000 Open Generator ET Tubes having previous identified degradation
                                  -acceptable.             h 201841   Hydraulic Snubber   MT   MT; No   recordable indications Integral Attachment          acceptable.
>20X.ET;All previous indications
FWU-39 M.
>20%were examined to the extent of degradation as a minimum.See the 1990 Eddy Current Examination Report for details.  
Summary                       NDE Exam          Results 202040   Rigid Support       VT-3 VT-3No recordable indications FWU-29                      acceptable.
~i&#xc3; Summary NDE Exam Results 801150 20K Rotating Random Sample on open Generator Tubes.ET ET;20X Random sample of all open unsleeved tubes were examined full length.See the 1990 Eddy'urrent Examination Report for details.801200 100X of all Unsleeved Tubes on open Generator Tubes.ET ET;100X of all open unsleeved tubes were examined to the g1 Tube Support on the Hot Leg.See the 1990 Eddy Current Examination Report for details.801350 20X Rotating ET Random Sample on each type of Sleeve.ET;20X Random sample of each type of sleeved Generator Tube were examined from sleeve end to sleeve end as a minimum.See the 1990 Eddy Current Examinatio'n Report for details.P.SYSTEM PRESSURE TESTS:~Casa: 2 Summary NDE Exam Results 350710 RSSP-15.7.1 Charging System through the Regenerative Heat Exchanger.
L'>
VT-2 VT-2: no recordable indications or leakage-acceptable./
pl JI
Summary NDE Exam Results 361600 RSSP-13.16 CVCS"A" Holdup Tank VT-2, VT-2: no recordable indications-acceptable.
 
Cannot examine under tank due to support.361700 361800 RSSP-13.17 CVCS"B" Holdup Tank RSSP-13.18 CVCS"D" Holdup Tank VT-2 VT-2 VT-2: no recordable indications-acceptable.
E. STEAM GENERATOR TUBING:
Cannot examine under tank due to support.VT-2: no recordable indications-acceptable.
Summary                                   NDE Exam         Results 800000     Open   Generator             ET   ET; All previous indications Tubes having                      >20X were examined to the previous identified                extent of degradation as a degradation >20X.                  minimum. See the 1990 Eddy Current Examination Report for details.
Cannot examine under tank due to support.
800150     20% Rotating                 ET  ET; 20X Random sample    of  all Random Sample     on               open unsleeved tubes were open Generator                    examined   full length. Tube R3-Tubes.                            C39 was programed but not examined   full length. See the 1990 Eddy Current Examination Report   for details.
I fi ,n g,'~asks'g~a 3 Summary NDE Exam Results 411000 PT-7 Leakage of Reactor Coolant System VT-2 VT-2: no recordable indications acceptable.
800200     100K   of all               ET   ET; 100X   of all open unsleeved tubes were examined to the 41
Insig.Boron residue found and reported to the Station by work requests for the following; valve 392A bonnet, valve 700 packing, FIP 180, valve 924 bonnet bolts&valve 427-acceptable.
          'nTubes.open Unsleeved Tubes Generator              Tube Support on the Hot Leg.
415300 PT-30, Containment VT-2 VT-2: no recordable indications Spray Rings, open all nozzles appear to have flow flow path test.-acceptable.
See the 1990 Eddy Current Examination Report for details.
400800 CVCS Holdup Tanks VT-2 VT-2: no recordable indications
800350     20X Rotating                 ET  ET; 20X Random sample   of each Random Sample on                  type of sleeved Generator Tube
&.Piping or leakage-acceptable.
        ,  each type    of Sleeve.            were examined from sleeve end to sleeve end as a minimum.
400805 CVCS Charging Letdown outside containment VT-2 VT-2: no recordable indications or leakage-acceptable.
Sleeved Tube R19-C22 was programed (excess of 20X) but not examined. See,the 1990 Eddy Current Examination Report
400820 CVCS Boric Acid Storage Tanks 8c, Piping VT-2 VT-2: no recordable indications or leakage-acceptable.
                    ~
400825 CVCS Boric Acid Evaporizer-Demineralizers.
for details.
VT-2 VT-2: no recordable indications or leakage-acceptable.
        ~
401100 Diesel Generators VT-2 VT-2: no recordable indications or leakage-acceptable.
NDE R'ummary Exam         Results 801000     Open   Generator             ET   ET;  All previous indications Tubes having                       >20% were examined to the previous identified                extent of degradation as a degradation >20X.                  minimum. See the 1990 Eddy Current Examination Report for details.
ly G.SNUBBER PROGRAM: 1./team Generator A~raw n'ummary NDE Exam Results 600080 SGA-7 Hydraulic Snubber Serial Number: 77-28073-A VT-3 No recordable indications.
~i
Insignificant:
&#xc3;
Serial numbers 78t8 are inverted with each other.Fluid level 1" from top.Temperature 65 F.Setting 2 7/16"-Acceptable.
 
600090 SGA-8 Hydraulic Snubber Serial Number: 77-28073-A VT-3 No recordable indications.
Summary                         NDE Exam         Results 801150   20K Rotating           ET   ET; 20X Random sample of all Random Sample  on          open unsleeved tubes were open Generator              examined full length. See the Tubes.                      1990 Eddy'urrent Examination Report for details.
Insignificant:
801200   100X of all           ET   ET; 100X of all open unsleeved Unsleeved Tubes              tubes were examined to the g1 on open Generator            Tube Support on the Hot Leg.
Hammer marks on the snubber block.Serial numbers 78c8 are inverted with each other.Fluid level 1".No tag on No.8.Temperature 65 F.Setting: 2 1/2" Acceptable.
Tubes.                      See the 1990 Eddy Current Examination Report for details.
~~a~~g: Summary NDE Exam Results 600120 SGB-3 Hydraulic Snubber Serial Number: 77-28073-A VT-3 No recordable indications.
801350   20X Rotating           ET   ET; 20X Random sample of each Random Sample  on          type of sleeved Generator Tube each type  of Sleeve.      were examined from sleeve end to sleeve end as a minimum.
Insignificant:
See the 1990 Eddy Current Examinatio'n Report for details.
No ID stamp on snubber.Temperature:
P. SYSTEM PRESSURE TESTS:
65 F.Setting: 2 7/8"-Acceptable.
        ~Casa: 2 Summary                         NDE Exam         Results 350710   RSSP-15.7.1           VT-2 VT-2: no recordable indications Charging System              or leakage acceptable./
600130 SGB-4 Hydraulic Snubber Serial Number: 77-28073-A VT-3 No recordable indications.
through the Regenerative Heat Exchanger.
Insignificant:
Summary                         NDE Exam         Results 361600   RSSP-13.16             VT-2, VT-2: no recordable indications CVCS  "A" Holdup            -acceptable. Cannot examine Tank                        under tank due to support.
No ID tag.Hammer marks on snubber block Temperature 65 F.Setting 2 1/2"-Acceptable.
361700   RSSP-13.17             VT-2  VT-2: no recordable indications CVCS  "B" Holdup             -acceptable. Cannot examine Tank                         under tank due to support.
IL Draw~~o C-16 Summary NDE Exam Results 600200 VT-3-38-AFU-03 Mechanical Snubber Serial Number: 20925 Model PSA-1 No recordable indications.
361800  RSSP-13.18             VT-2 VT-2: no recordable indications CVCS  "D" Holdup            -acceptable. Cannot examine Tank                        under tank due to support.
Temperature 84 F.Setting: 2" Acceptable.
I fi
q I I',
,n
4~Summary'ar 2" 2 NDE Exam~Dawi~~C-E Results 600220 AFU-31 Mechanical Snubber Serial Number: 24452 Model PSA-1 VT-3 No recordable indications.
 
Temperature:
g,'~asks'     g ~a     3 Summary                             NDE Exam         Results 411000   PT-7                     VT-2 VT-2: no recordable indications Leakage    of                    acceptable. Insig. Boron Reactor Coolant                residue found and reported to System                        the Station by work requests for the following; valve 392A bonnet, valve 700 packing, FIP 180, valve 924 bonnet bolts &
100 F.Setting: 2"-Acceptable.
valve 427 -acceptable.
600240 AFU-34 Mechanical Snubber Serial Number: 16379 Model PSA-1 VT-3 No recordable indications'emperature:
415300   PT-30, Containment       VT-2 VT-2: no recordable indications Spray Rings, open             all nozzles appear to have flow flow path test.               -acceptable.
98 F.Setting: 2 7/8".-Acceptable.
400800   CVCS     Holdup Tanks     VT-2 VT-2: no recordable indications
Summary*NDE Exam~Dr win:~C-Results 600260 AFU-52 Mechanical Snubber Serial Number: 24453 Model PSA-1 VT-3 No recordable ind'ications.
          &. Piping                     or leakage acceptable.
Temperature:
400805   CVCS     Charging         VT-2 VT-2: no recordable indications Letdown outside                or leakage acceptable.
100 F.Setting: 1 3/4"~Acceptable.
containment 400820   CVCS     Boric Acid       VT-2 VT-2: no recordable indications Storage Tanks      8c,          or leakage acceptable.
Summary 600280 AFU-75 Mechanical Snubber Serial Number: 20924 Model'PSA-1 NDE Exam VT-3~aw~in: g-18 Results No recordable indications.
Piping 400825   CVCS     Boric Acid       VT-2 VT-2: no recordable indications Evaporizer-                    or leakage - acceptable.
Temperature:
Demineralizers.
102 F.Setting: 2".-Acceptable.
401100   Diesel Generators         VT-2 VT-2: no recordable indications or leakage acceptable.
600300 AFU-98 Mechanical Snubber Serial Number: 24454 Model PSA-1 VT-3 No recordable indications.
ly G. SNUBBER PROGRAM:
Temperature:
: 1. /team Generator A         ~raw n'ummary NDE Exam                   Results 600080     SGA-7               VT-3     No       recordable indications.
302 F.Setting: 1 1/2".-Acceptable.
Hydraulic Snubber            Insignificant: Serial             numbers Serial Number:                78t8       are inverted with each 77-28073-A                    other. Fluid level 1" from top. Temperature 65 F.
lpEq.E Summary Number 600320 600339 Com onent AFU-101 Mechanical Snubber Serial Number: 15751 Model PSA-1 AFU-103 (EAST)Mechanical Snubber Serial Number: 18184 Model PSA-3 NDE Exam VT-3 VT-3~Dawin: C-1C Results'o recordable indications, Temperature:
Setting         2   7/16"   Acceptable.
302 F.Setting: 3 1/4" Acceptable.
600090     SGA-8               VT-3     No       recordable indications.
No recordable indications.
Hydraulic Snubber            Insignificant:           Hammer marks Serial Number:                on the snubber           block. Serial 77-28073-A                    numbers 78c8 are           inverted with each       other. Fluid level 1".
Temperature:
No tag on No.             8. Temperature 65 F.         Setting:     2 1/2" Acceptable.
67 F.Setting: 2 5/8" Acceptable.
                                  ~~a~~g:
600340 AFU-103 (WEST)Mechanical Snubber Serial Number: 18185 Model PSA-3 VT-3 No recordable indications.
Summary                         NDE Exam                   Results 600120     SGB-3               VT-3     No       recordable indications.
Temperature:
Hydraulic Snubber            Insignificant:           No ID stamp Serial Number:                on snubber.           Temperature: 65 F.
67 F.Setting: 3 1/8" Acceptable.
77-28073-A                    Setting:         2 7/8" Acceptable.
Number Com onent.I-'ummary NDE Exam~Drawin'C-Results 600360 600380 AFU-109 Hydraulic Snubber Serial Number: 30986 Size 1.5 AFU-111 Mechanical Snubber Serial Number: 16377 Model PSA-1 VT-3 VT-3 Rejected: Bolt holding reservoir loose.NCR 90-104 Replaced with a new snubber, SN 30986.Temperature:
600130     SGB-4               VT-3     No       recordable indications.
76 F.Setting: 2 3/4" Acceptable.
Hydraulic Snubber            Insignificant:           No ID tag.
No recordable indications.
Serial Number:                Hammer marks on snubber block 77-28073-A                    Temperature 65 F. Setting 2 1/2" Acceptable.
Temperature:
IL Draw~           ~o     C-16 Summary                         NDE Exam                   Results 600200     AFU-03               VT-3    No       recordable indications.
76 F.Setting: 2 1/4" Acceptable.
Mechanical Snubber            Temperature           84 F.
600400 AFU-123 Mechanical Snubber Serial Number: 16378 Model PSA-1 VT-3 No recordable indications.
Serial Number:                Setting: 2" 20925                        Acceptable.
Temperature:
Model PSA-1 q I I',
290 F.'etting:
 
1 5/8" Acceptable.
4 ~     'ar   2   "   2
600420 AFU-124 Mechanical Snubber Serial Number: 244 Model PSA-1 No recordable indications.
                                    ~Dawi~       ~C- E Summary                        NDE Exam            Results 600220   AFU-31               VT-3   No recordable indications.
Temperature:
Mechanical Snubber          Temperature:     100 F.
290 F.Setting: 2"-Acceptable.
Serial  Number:            Setting:     2"   Acceptable.
4 i$'rl Summary 600460~n~C--00-B BDU-16 Mechanical Snubber Serial Number: 10182 Model PSA-5 NDE Exam VT-3~Daw~i: B-3 1 Results No recordable indications.
24452 Model PSA-1 600240   AFU-34               VT-3  No  recordable Mechanical Snubber                             98 F.
Temperature:
indications'emperature:
68 F.Setting: 2 1/2" Acceptable.
Serial  Number:            Setting:     2 7/8".
6.Summary NDE Exam~aw~Q-29 Results 600530 CCU-43 Mechanical Snubber Serial Number: 11462 Model PSA-1 VT-3 No recordable indications.
16379                          Acceptable.
Temperature:
Model PSA-1
68 F.Setting: 1 1/8"-Acceptable.
                          *         ~Dr win:   ~C-Summary                        NDE Exam            Results 600260   AFU-52               VT-3   No recordable ind'ications.
Summary 600610 CCU-57 Mechanical Snubber Serial Number: 04160305 Model PSA-3 NDE Exam VT-3~~w'~C-34 Results No recordable indications.
Mechanical Snubber          Temperature:     100 F.
Temperature:
Serial  Number:            Setting: 1 3/4"                       ~
65 F.Setting: 2 3/8" Acceptable.
24453                          Acceptable.
8.Summary 600710 CCU-71 Mechanical Snubber Serial Number: 18193 Model PSA-3 NDE~Exa VT-3~Dgwi~n: Q-30 Results No Recordable Indications.
Model PSA-1
Temperature:
                                    ~aw~in   : g-18 Summary                        NDE Exam            Results 600280    AFU-75                VT-3  No recordable indications.
64 F.Setting: 2 1/2"-Acceptable.  
Mechanical Snubber          Temperature:     102 F.
~s 9~Summary Number 600880 2~ch~Ltdown: Com onent CVU-26 Mechanical Snubber Serial Number: 20880 Model PSA-1 NDE Exam VT-3~Drawin~A-2 Results No Recordable Indications Temperature:
Serial  Number:            Setting: 2".
50 F.Setting: 2"-Acceptable.
20924                        Acceptable.
10.J J"~ige,'VC~Q('eLaJLa 2~El~em~~rawin:~S-Summary Number 600900 Com onent CVU-46 Mechanical Snubber Serial Number: 23517 Model PSA 1/4 NDE Exam VT-3 Results No Recordable Indications.
Model 'PSA-1 600300   AFU-98               VT-3   No recordable indications.
Temperature:
Mechanical Snubber          Temperature:       302 F.
50 F.Setting: 2 Acceptable.
Serial  Number:            Setting:     1 1/2".
Summary~umber 600920 CVU-49 Mechanical Snubber Serial Number: 9483 Model PSA 1/2 NDE-Exam VT-3 j)raw~i:-~27 Resu ts No Recordable Indications.
24454                          Acceptable.
Temperature:
Model PSA-1 lp Eq. E
48 F.Setting: 1 1/2"-Acceptable.
 
Summary Number~CV S Let~ow~elJJIJal NDE Exam~Draw': B-32 Results 600940 CVU-80 Mechanical Snubber Serial Number: 23516 Model PSA 1/4 VT-3 No Recordable Indications.
                                      ~Dawin:            C-1C Summary                         NDE Number   Com     onent         Exam          Results'o 600320    AFU-101               VT-3      recordable indications, Mechanical Snubber           Temperature:            302 F.
Temperature:
Serial     Number:           Setting: 3 1/4" 15751                           Acceptable.
50 F.Setting: 1 1/2"-Acceptable.
Model PSA-1 600339    AFU-103 (EAST)         VT-3  No  recordable indications.
II IV 12.~eact r~Coo ant~Pum 1B Seal Water: Summary Number Com onent NDE Exam Results 600960 CVU-103 Mechanical Snubber Serial Number: 24450 Model PSA-1 VT-3 No Recordable Indications.
Mechanical Snubber           Temperature:            67 F.
Temperature:
Serial     Number:           Setting: 2 5/8" 18184                           Acceptable.
66 F.Setting: 2"-Acceptable.
Model PSA-3 600340    AFU-103 (WEST)        VT-3 No  recordable indications.
600980 CVU-104 Mechanical Snubber Serial Number: 24449 Model PSA-1 VT-3 No Recordable Indications, Temperature:
Mechanical Snubber          Temperature:           67 F.
62 F.Setting: 2"-Acceptable.
Serial    Number:          Setting: 3 1/8" 18185                        Acceptable.
13'eactor~Coo a t~um~1~Sea~Wat r:~Draw': B-34 Summary Number NDE Exam Results 601000 CVU-186 Mechanical Snubber Serial Number: 16541 Model PSA-1 VT-3 No Recordable Indications.
Model PSA-3
Temperature:
        .I                          ~Drawin  'C-
60 F.Setting: 1 5/8" Acceptable.
          'ummary NDE Number    Com    onent          Exam          Results 600360    AFU-109                VT-3  Rejected: Bolt holding Hydraulic Snubber           reservoir loose. NCR 90-104 Serial     Number:           Replaced with a new snubber, 30986                        SN 30986. Temperature:                 76 F.
14.Summary Number~CV S~Le dow Com onent NDE Exam~rw~B-35 Results 601040 CVU-345 Mechanical Snubber Serial Number: 9491 Model PSA 1/2 VT-3 No Recordable Indications.
Size 1.5                    Setting:           2 3/4" Acceptable.
Temperature:
600380   AFU-111                VT-3  No  recordable indications.
69 F.Setting: 1 1/2" Acceptable.
Mechanical Snubber           Temperature:            76 F.
601060 CVU-351 Mechanical Snubber Serial Number: 12508 Model PSA 1/2 VT-3-No Recordable Indications.
Serial     Number:           Setting: 2 1/4" 16377                           Acceptable.
Temperature:
Model PSA-1 600400    AFU-123                VT-3 No  recordable indications.
63 F.Setting: 1"-Acceptable.  
Mechanical Snubber          Temperature:           290 Serial    Number:                               1 5/8" F.'etting:
~'
16378                          Acceptable.
Summary Number Com onent NDE Exam~Dx awin B-36 Results 601080 CVU-372 Mechanical Snubber Serial Number: 12917 Model PSA 1/2=VT-3 No Recordable Indications.
Model PSA-1 600420    AFU-124                      No recordable indications.
Temperature:
Mechanical Snubber          Temperature:             290 F.
63 F.Setting: 7/8"-Acceptable.
Serial     Number: 244       Setting: 2" Model PSA-1                    Acceptable.
15'ummary Number Com onent NDE Exam~Dawi~~2 Results 601100 601110 FWU-5 VT-3 Hydraulic Snubber Serial Number: 2500-10-152 Model Berger Paterson Size 10 FWU-3 VT-3 Hydraulic Snubber Serial Number: 2500-10-153 Model Berger Paterson Size 10 No Recordable Indications.
4 i$
Temperature:
'rl
69 F.Setting: 4 1/16" Acceptable.
 
        ~n~     C- B     ~Daw~i: B-3 1 Summary                      NDE Exam          Results 600460    BDU-16            VT-3  No recordable indications.
Mechanical Snubber      Temperature:   68 F.
Serial  Number:          Setting: 2 1/2" 10182                      Acceptable.
Model PSA-5 6.
                                  ~aw~     Q-29 Summary                      NDE Exam          Results 600530   CCU-43             VT-3 No recordable indications.
Mechanical Snubber      Temperature:   68 F.
Serial  Number:          Setting: 1 1/8" 11462                    Acceptable.
Model PSA-1
                                  ~~w'~     C-34 Summary                      NDE Exam          Results 600610    CCU-57            VT-3  No recordable indications.
Mechanical Snubber      Temperature:   65 F.
Serial  Number:          Setting: 2 3/8" 04160305                    Acceptable.
Model PSA-3 8.
                                  ~Dgwi~n: Q-30 Summary                      NDE
                            ~Exa          Results 600710    CCU-71            VT-3  No Recordable Indications.
Mechanical Snubber      Temperature: 64 F.
Serial  Number:          Setting:   2 1/2" 18193                      Acceptable.
Model PSA-3
 
~ s 9 ~ 2   ~ch   ~Ltdown:
                                            ~Drawin    ~A-2 Summary                                NDE Number      Com   onent               Exam            Results 600880      CVU-26                     VT-3    No  Recordable Indications Mechanical Snubber                 Temperature: 50 F.
Serial  Number:                  Setting: 2" 20880                              Acceptable.
Model PSA-1
: 10. J J"
            ~ige,'VC   ~   Q('eLaJLa 2 ~El~em~     ~rawin:   ~S-Summary                               NDE Number     Com   onent               Exam            Results 600900      CVU-46                     VT-3   No Recordable Indications.
Mechanical Snubber                Temperature: 50 F.
Serial  Number:                  Setting: 2 23517                                Acceptable.
Model  PSA 1/4 j)raw~i:- ~27 Summary                                NDE
~umber                                -Exam            Resu ts 600920     CVU-49                     VT-3    No  Recordable Indications.
Mechanical Snubber                 Temperature: 48 F.
Serial   Number:                   Setting:  1  1/2" 9483                                 Acceptable.
Model PSA 1/2
            ~CV S  Let~ow~
elJJIJal                  ~Draw':    B-32 Summary                                NDE Number                                Exam           Results 600940      CVU-80                    VT-3   No Recordable Indications.
Mechanical Snubber                Temperature: 50 F.
Serial  Number:                  Setting: 1   1/2" 23516                                Acceptable.
Model PSA 1/4 II IV
: 12.   ~eact   r ~Coo   ant ~Pum     1B Seal Water:
Summary                                 NDE Number     Com onent                   Exam               Results 600960     CVU-103                     VT-3      No Recordable Indications.
Mechanical Snubber                     Temperature: 66 F.
Serial   Number:                       Setting: 2" 24450                                     Acceptable.
Model PSA-1 600980    CVU-104                      VT-3       No Recordable Indications, Mechanical Snubber                      Temperature: 62 F.
Serial    Number:                      Setting: 2" 24449                                    Acceptable.
Model PSA-1 13 Summary
        'eactor       ~Coo   a t ~um   ~1 NDE
                                              ~Sea
                                                    ~Draw ':
                                                      ~Wat r:
B-34 Results Number                                   Exam 601000     CVU-186                       VT-3       No Recordable Indications.
Mechanical Snubber                      Temperature: 60 F.
Serial    Number:                      Setting:   1 5/8" 16541                                      Acceptable.
Model PSA-1
: 14. ~CV S ~Le dow
                                                    ~rw~ B-35 Summary                                  NDE Number    Com  onent                  Exam                Results 601040     CVU-345                       VT-3       No Recordable Indications.
Mechanical Snubber                      Temperature: 69 F.
Serial    Number:                      Setting:   1 1/2" 9491                                        Acceptable.
Model PSA 1/2 601060    CVU-351                      VT     No Recordable Indications.
Mechanical Snubber                      Temperature: 63 F.
Serial    Number:                      Setting:   1" 12508                                      Acceptable.
Model PSA 1/2
~ '
                                            ~Dx awin B-36 Summary                                NDE Number          Com  onent            Exam          Results 601080           CVU-372             VT-3 No   Recordable Indications.
Mechanical Snubber        Temperature: 63 F.
Serial  Number:            Setting: 7/8" 12917                        Acceptable.
Model  PSA 1/2=
15
                                            ~Dawi~    ~2 NDE
        'ummary Number           Com onent           Exam           Results 601100           FWU-3                VT-3 No  Recordable Indications.
Hydraulic Snubber         Temperature: 69 F.
Serial Number:           Setting: 4 1/16" 2500-10-153                    Acceptable.
Model Berger Paterson Size 10 601110          FWU-5                VT-3 No Recordable Indications.
Hydraulic Snubber         Temperature: 69 F.
Serial Number:           Setting:  2 1/2" 2500-10-152                  Acceptable.
Model Berger Paterson Size 10 16.
                                            ~Daw~      B-13 Summary                              NDE Number                                Exam          Results 601120          FWU-8                VT-3  No  Recordable Indications.
Mechanical Snubber        Temperature: 58 F.
Serial  Number:            Setting:   3 1/8" 8033                          Acceptable.
Model PSA-10 601130          FWU-12              VT-3  No  Recordable Indications.
Mechanical Snubber        Temperature: 58 F.
Serial  Number:            Setting: 3" 8034                          Acceptable.
Model PSA-10 1'I 17
                '~ice:  14  -FW-900-1A      ~aw~i:    ~B- 1
        'ummary NDE Number            Com  onent            Exam        Results 601140            FWU-15                VT-3 No  Recordable Indications.
Mechanical Snubber        Temperature: 241 F.
Serial  Number:            Setting:  2 5/8" 9358/51644                  Acceptable.
Model PSA-35 601150            FWU-17                VT-3 No  Recordable Indications.
Mechanical Snubber        Insignificant: Corrosion on Serial  Number:            housing. Tube marks on 9392                      transition tube and housing.
Model PSA-35              Acceptable. Temperature:    242 F.
Setting: 5"  Acceptable.
601160            FWU-18                VT-3 No  Recordable Indications.
Mechanical Snubber        Temperature: 211 F.
Serial  Number:            Setting:  4  3/4" 7067                        Acceptable.
Model PSA-35 graw~n:  ~HE-Summary                                NDE Number            Com  onent            Exam        Results 601170            FWU-20                VT-3  Reject:  Top  of snubber was Mechanical Snubber          hitting  mounting bracket. NCR Serial  Number:            90-246: Angular tolerance OK.
7049                        Clearance adequate.      Use-as-Model PSA-35                is per E.K. Voci  Acceptable.3" Temperature:79 F.; Setting:
Acceptable.
601180            FWU-21                VT-3  No  Recordable Indications.
Hydraulic Snubber          Temperature: 220 F.
Serial  Number:            Setting: 3 11/16" F51035                      Acceptable.
Model HSSA-20 601190            FWU-23                VT-3  No  Recordable Indications.
Mechanical Snubber          Temperature: 250 F.
Serial  Number:            Setting:  2 3/4" 8630                          Acceptable.
Model PSA-10 601200            FWU-24                VT-3  No  Recordable Indications.
Mechanical Snubber          Temperature: 280 F.
Serial  Number:            Setting: 3" 10061                        Acceptable.
Model PSA-10
~42, s,g<
  'L l
L,
,4
 
Summary                      NDE Number  Com  onent          Exam        Results 601209  FWU-26 (EAST)            No Recordable Indications.
Mechanical Snubber        Temperature: 156 F.
Serial  Number:          Setting:  3" 18179                      Acceptable.
Model PSA-3 601210  FWU-26 (WEST)            No Recordable Indications.
Mechanical Snubber        Temperature: 195 F.
Serial  Number:          Setting: 3" 18180                        Acceptable.
Model PSA-3
                                  /raw'i~  QE-5 Summary                      NDE Number  Com  onent          Exam        Results 601220  FWU-32              VT-3 No Recordable Indications.
Mechanical Snubber        Temperature: 222 F.
Serial  Number:          Setting:  3 1/4" 7053                        Acceptable.
Model PSA-35
                                  ~rw~n: ~1 Summary                      NDE Number  Com  onent          Exam        Results 601230  FWU-38                    No  Recordable Indications.
Mechanical Snubber        Temperature: 260 F.
Serial  Number:          Setting:  2 3/4" 9395                        Acceptable.
Model PSA-35 601240  FWU-39                    No  Recordable Indications.
Mechanical Snubber        Temperature: 177 F.
Serial  Number:          Setting:  3 7/8" 9354/51642                  Acceptable.
Model PSA-35 601250  FWU-40                    No Recordable Indications.
Mechanical Snubber        Temperature: 267 F.
Serial  Number:          Setting:  3 1/2" 7066                        Acceptable.
        'odel  PSA-35 li 18
                    ~pe:    4-B-FW-900-1B      l~rawi~  HE-8
        'ummary NDE Number                                    Exam        Results 601260                                    VT-3 Reject: Insulation on Mechanical Snubber        valve 4012 resting on snubber; Serial  Number:            binding. Re-exam after repair.
No Recordable Indications.
No Recordable Indications.
Temperature:
6158 Model PSA-35              Temperature: 73 F,
69 F.Setting: 2 1/2"-Acceptable.
        'WU-42                                Setting: 4 3/8" Acceptable.
16.Summary Number 601120 FWU-8 Mechanical Snubber Serial Number: 8033 Model PSA-10 NDE Exam VT-3~Daw~B-13 Results No Recordable Indications.
601270              FWU-44                VT-3 Rejec't: Insulation not removed.
Temperature:
Hydraulic Snubber          1) Locknut not tight on snubber Serial  Number:           side. 2) Snubber does not move.
58 F.Setting: 3 1/8" Acceptable.
643864-20                  3) No oil indicator.
601130 FWU-12 Mechanical Snubber Serial Number: 8034 Model PSA-10 VT-3 No Recordable Indications.
Model HSSA-30              4) Reservoir on bottom.
Temperature:
: 5) Cotter Pin missing.
58 F.Setting: 3"-Acceptable.
: 6) Turnbuckle not on print NCR 90-172 generated. Re-exam after repairs. Temperature:    75 F., Setting:   3  3/4",Acceptable.
1'I 17'ummary Number 601140'~ice: 14-FW-900-1A Com onent FWU-15 Mechanical Snubber Serial Number: 9358/51644 Model PSA-35 NDE Exam VT-3~aw~i:~B-1 Results No Recordable Indications.
601280              FWU-47                VT-3 No Recordable Indications.
Temperature:
Mechanical Snubber         Insignificant: Boot on snubber Serial Number:           has rip with tape on it.
241 F.Setting: 2 5/8"-Acceptable.
7474                      Trouble card written for boot.
601150 601160 FWU-17 Mechanical Snubber Serial Number: 9392 Model PSA-35 FWU-18 Mechanical Snubber Serial Number: 7067 Model PSA-35 VT-3 VT-3 No Recordable Indications.
Model PSA-35               Temperature: 47 F., Setting:
Insignificant:
4.875"  Acceptable.
Corrosion on housing.Tube marks on transition tube and housing.Acceptable.
601290              FWU-48                VT-3 No Recordable Indications.
Temperature:
Mechanical Snubber        Insignificant:   Very light Serial  Number:            corrosion that was cleaned 7475                      off. Hole in'oot on bottom.
242 F.Setting: 5"-Acceptable.
Model PSA-35              Temperature: 66 F.
No Recordable Indications.
Setting: 4  1/4"   Acceptable.
Temperature:
601300              FWU-51                VT-3 No Recordable Indications.
211 F.Setting: 4 3/4"-Acceptable.
Mechanical Snubber        Insignificant: Very light Serial  Number:            corrosion after cleaning.
Summary Number Com onent NDE Exam graw~n:~HE-Results 601170 FWU-20 Mechanical Snubber Serial Number: 7049 Model PSA-35 VT-3 Reject: Top of snubber was hitting mounting bracket.NCR 90-246: Angular tolerance OK.Clearance adequate.Use-as-is per E.K.Voci-Acceptable.
7483                      Temperature:   61 F.
Temperature:79 F.;Setting: 3"-Acceptable.
Model PSA-35              Setting: 4 1/2". Setting      on chart 4 3/8" -Acceptable.
601180 FWU-21 Hydraulic Snubber Serial Number: F51035 Model HSSA-20 VT-3 No Recordable Indications.
601310              FWU-52                VT-3 No Recordable Indications.
Temperature:
Mechanical Snubber         Temperature: 182 F.
220 F.Setting: 3 11/16"-Acceptable.
Serial Number:           Setting: 1.875" 8607                          Acceptable.
601190 FWU-23 Mechanical Snubber Serial Number: 8630 Model PSA-10 VT-3 No Recordable Indications.
Model PSA-10 601320              FWU-54                VT-3 No  Recordable Indications.
Temperature:
Mechanical Snubber        Temperature: 187 F.
250 F.Setting: 2 3/4" Acceptable.
Serial  Number:           Setting: 3 1/2" 7482                        Acceptable.
601200 FWU-24 Mechanical Snubber Serial Number: 10061 Model PSA-10 VT-3-45-No Recordable Indications.
Model PSA-35
Temperature:
 
280 F.Setting: 3"-Acceptable.  
Summary                            NDE Number    Com  onent              Exam          Results 601330    FWU-57                  VT-3 No Recordable Indications.
~42, s,g<'L l L, ,4 Summary Number 601209 Com onent FWU-26 (EAST)Mechanical Snubber Serial Number: 18179 Model PSA-3 NDE Exam Results No Recordable Indications.
Mechanical Snubber          Temperature: 187 F.
Temperature:
Serial  Number:            Setting: 2.875" 10064                          Acceptable.
156 F.Setting: 3"-Acceptable.
Model PSA-10
601210 FWU-26 (WEST)Mechanical Snubber Serial Number: 18180 Model PSA-3 No Recordable Indications.
: 19. Maia Steam    ~Loo ~A
Temperature:
                                        ~Draw ':  B-8 Summary                            NDE Number    Com  onent              Exam          Results 601350    MSU-2                  VT-3 No Recordable Indications.
195 F.Setting: 3" Acceptable.
Mechanical Snubber          Temperature: 68 F.
Summary Number 601220 Com onent FWU-32 Mechanical Snubber Serial Number: 7053 Model PSA-35 NDE Exam VT-3/raw'i~QE-5 Results No Recordable Indications.
Serial  Number:            Setting:   3 1/4" 7048                            Acceptable.
Temperature:
Model PSA-35 601360    MSU-3                  VT-3 No Recordable Indications.
222 F.Setting: 3 1/4"-Acceptable.
Mechanical Snubber          Temperature: 67 F.
Summary Number 601230 Com onent FWU-38 Mechanical Snubber Serial Number: 9395 Model PSA-35 NDE Exam~rw~n:~1 Results No Recordable Indications.
Serial  Number:            Setting: 3" 7060                            Acceptable.
Temperature:
Model PSA-35 20 'a'n    ~Si~aa~ ~Loo B:
260 F.Setting: 2 3/4"-Acceptable.
                                        ~aw~in  '-8 Summary                           NDE Number     Com onent             Exam          Results 601369    MSU-7 (TOP)             VT-3 No Recordable Indications.
601240 FWU-39 Mechanical Snubber Serial Number: 9354/51642 Model PSA-35 No Recordable Indications.
Mechanical Snubber          Insi,gnificant:    No damage is Serial  Number:             apparent to snubber or rear 7051                        brackets. Total movement is Model PSA-35                significant -2". Drag force present. Temperature: 80 F.
Temperature:
Setting:   2  3/4". Acceptable to ME-256 per A. Butcavage.
177 F.Setting: 3 7/8"-Acceptable.
601370    MSU-7 (BOTTOM)         VT-3 No Recordable Indications.
601250 FWU-40 Mechanical Snubber Serial Number: 7066'odel PSA-35 No Recordable Indications.
Mechanical Snubber          Insignificant:    No damage to Serial  Number:             snubber. Present movement 2".
Temperature:
7047                        Drag  force present.
267 F.Setting: 3 1/2" Acceptable.
Model PSA-35                Temperature: 80 F., Setting:
li 18'ummary Number~pe: 4-B-FW-900-1B NDE Exam l~rawi~HE-8 Results 601260 601270 601280 601290 601300'WU-42 Mechanical Snubber ,, Serial Number: 6158 Model PSA-35 FWU-44 Hydraulic Snubber Serial Number: 643864-20 Model HSSA-30 FWU-47 Mechanical Snubber Serial Number: 7474 Model PSA-35 FWU-48 Mechanical Snubber Serial Number: 7475 Model PSA-35 FWU-51 Mechanical Snubber Serial Number: 7483 Model PSA-35 VT-3 VT-3 VT-3 VT-3 VT-3 Reject: Insulation on valve 4012 resting on snubber;binding.Re-exam after repair.No Recordable Indications.
3". Acceptable to ME-256 per A.
Temperature:
Butcavage.
73 F, Setting: 4 3/8"-Acceptable.
 
Rejec't: Insulation not removed.1)Locknut not tight on snubber side.2)Snubber does not move.3)No oil indicator.
Summary                       NDE Number Com onent             Exam          Results 601380  MSU-8                  VT-3 No  Recordable Indications.
4)Reservoir on bottom.5)Cotter Pin missing.6)Turnbuckle not on print NCR 90-172 generated.
Hydraulic Snubber          Insignificant:      Snubber does Serial  Number:            not, move by hand.      Temperature:
Re-exam after repairs.Temperature:
G-20968-1-30                100  F., Setting   3 1/2",
75 F., Setting: 3 3/4",Acceptable.
Model HSSA-20                Acceptable.
No Recordable Indications.
3  -B- S-6 0-1B      ~Draw '~n'B- 1 0 Summary                       NDE Number Com onent             Exam          Results 601390  MSU-12                VT-3 No  Recordable Indications.
Insignificant:
Mechanical Snubber         Insignificant:      Pigeon feces.
Boot on snubber has rip with tape on it.Trouble card written for boot.Temperature:
Serial   Number:           Acceptable per NCR 90-119.
47 F., Setting: 4.875"-Acceptable.
9400                        Temperature: 190 F.
No Recordable Indications.
Model PSA-35                Setting: 3.375" -Acceptable.
Insignificant:
601399  MSU-13 (EAST)          VT-3 No  Recordable Indications.
Very light corrosion that was cleaned off.Hole in'oot on bottom.Temperature:
Mechanical Snubber          Insignificant:      Pigeon feces.
66 F.Setting: 4 1/4"-Acceptable.
Serial   Number:           Acceptable per NCR 90-119.
No Recordable Indications.
1467                        Temperature: 200 F.
Insignificant:
Model PSA-100              Setting: 3.25" Acceptable.
Very light corrosion after cleaning.Temperature:
601400  MSU-13 (WEST)          VT-3 No  Recordable Indications.
61 F.Setting: 4 1/2".Setting on chart 4 3/8"-Acceptable.
Mechanical Snubber         Insignificant:      Pigeon feces, Serial   Number:           Acceptable per NCR 90-119.
601310 601320 FWU-52 Mechanical Snubber Serial Number: 8607 Model PSA-10 VT-3 VT-3-47-FWU-54 Mechanical Snubber Serial Number: 7482 Model PSA-35 No Recordable Indications.
1464                        Temperature: 200 F.
Temperature:
Model PSA-100              Setting: 3.25" Acceptable.
182 F.Setting: 1.875" Acceptable.
601409  MSU-15 (NORTH)        VT-3 No  Recordable Indications, Mechanical Snubber         Insignificant: Light rust; Serial   Number:           Does  not rotate-acceptable.
No Recordable Indications.
7476                        Temperature:    48  F., Setting: 3" Model PSA-35               Acceptable.
Temperature:
601410  MSU-15 (SOUTH)        VT-3 No  Recordable Indications.
187 F.Setting: 3 1/2"-Acceptable.  
Mechanical Snubber         Insignificant: Light rust.
Serial   Number:           Does  not rotate, acceptable.
7477                        Temperature: 48 F., Setting:
Model PSA-35               3 1/4"> -Acceptable.
601419  MSU-16 (NORTH)        VT-3 No  Recordable Indications.
Mechanical Snubber         Insignificant: Pigeon feces.
Serial   Number:           Acceptable per NCR 90-119.
7481                        Temperature: 190 F., Setting:
Model PSA-35                 3.875"  Acceptable.
IP 4.
s 'I, 4i P
 
                                  ~Drawin: B-10 Summary                      NDE Number  Com  onent          Exam        Results 1
601420  MSU-16 (SOUTH)      VT-3 No Recordable Indications.
Mechanical Snubber        Insignificant:   Pigeon feces.
Serial  Number:          Acceptable per NCR 90-119.
7480                      Temperature: 205 F. Setting:
Model PSA-35              4.375" Acceptable.
601429  MSU-18 (NORTH)       VT-3 No Recordable Indications.
Mechanical Snubber       Insignificant:  Pigeon feces.
Serial  Number:          Acceptable per NCR 90-119.
93695 1645                Temperature: 180 F.,
Model PSA-35              Setting: 3.625" Acceptable.
601430  MSU-18 (SOUTH)      VT-3 No Recordable Indications.
Mechanical Snubber        Insignificant:   Pigeon feces.
Serial  Number:          Acceptable per NCR 90-119.
937251646                Temperature: 160 F.
Model PSA-35              Setting: 3.375" -Acceptable.
601439  MSU-19 (NORTH)      VT-3 No Recordable Indications.
Mechanical Snubber        Insignificant: Light rust.
Serial  Number:          Does  not rotate. Acceptable.
9369                      Temperature: 325 F.
Model PSA'-35            Setting: 4.25" -Acceptable.
601440  MSU-19 (SOUTH)      VT-3 No Recordable Indications.
Mechanical Snubber        Insignificant: Light rust.
Serial  Number:          Does not rotate. Accept.
9372                      Temperature: 235 F.
Model PSA-35              Setting: 4.25" -Acceptable.
601450  MSU-22              VT-3 No Recordable Indications.
Mechanical Snubber       Insignificant: Light rust'.
Serial Number:           Does  not rotate. Accept.
9357                      Temperature: 235 F.
Model PSA-35              Setting: 4.375" -Acceptable.
601460  MSU-25              VT-3 No Recordable Indications.
Mechanical Snubber        Insignificant: Light rust.
Serial  Number:          Does not rotate. Accept.
1465                      Temperature: "235 F.
Model PSA-100            Setting: 4.125" -Acceptable.
I Summary                      NDE Exam        Results 601469  MSU-26 (TOP)        VT-3 No  Recordable Indications.
Mechanical Snubber        Insignificant: Light rust.
Serial Number:            Does not rotate.      Accept.
1465                      Temperature: 235 F., Setting:
Model PSA-100            4.125",  Acceptable.
601470  MSU-26 (BOTTOM)      VT-3 No  Recordable  Indications.
Mechanical Snubber        Insignificant: Light rust    on Serial Number:            attachment plate to pipe.
9389                      Temperature: 235 F., Setting:
Model PSA-35              1.5"  ,
Acceptable.
601480  MSU-27              VT-3 No  Recordable Indications.
Mechanical Snubber        Insignificant: Light rust.
Serial Number:            Does  not rotate. Accept.
9398                      Temperature:    235 F., Setting:
Model PSA-35              4.5", -Acceptable.
601490  MSU-29              VT-3 No  Recordable Indications Mechanical Snubber        Insignificant: Does not Serial Number:            rotate. Accept. Temperature:
1469                      416  F., Setting:  4  1/8" Model PSA-100            Acceptable.
601500  MSU-31              VT-3 No  Recordable Indications.
Mechanical Snubber        Temperature: 416 F.
Serial Number:            Setting:  2 5/8" 9356                          Acceptable.
Model PSA-35 601510  MSU-32              VT-3 No  Recordable Indications.
Mechanical Snubber        Temperature: 292 F.
Serial Number:            Setting:  2 1/2" 1093                        Acceptable.
Model PSA-100
/
J'
 
21 ~ ~Ma'n ~St.ea  ~Lo  A:
                                        ~ awi~n:  B-9 Summary                          NDE Number    Com  onent            Exam          Results 601520    MSU-38                VT-3  Reject: Snubber installed Mechanical Snubber          backward to print. NCR 90-101.
Serial  Number:            Snubber may be installed 180 1090                        deg. without change of Model PSA-100                function. Use-as-is. per E.K.
Voci. Acceptable.
601530    MSU-39                VT-3  No  Recordable Indications.
Mechanical Snubber          Insignificant:    Does  not Serial  Number:            rotate. Accept.
1087                        Temperature: 76 F.
Model PSA-100                Setting: 4 3/4" -Acceptable.
601540    MSU-40                VT-3  No  Recordable Indications.
Mechanical Snubber          Insignificant: Does not Serial  Number:            rotate. Accept.
1080                        Temperature:    416 F.
Model PSA-100                Setting:  4 5/8" -Acceptable.
601550    MSU-44                VT-3  No  Recordable Indications.
Mechanical Snubber          Insignificant: Does not Serial  Number:            rotate. No ID tag. Accept.
1468                        Temperature:    416 F.
Model PSA-100                Setting:  3 1/8" -Acceptable.
22 'KQX $ <CKR a'
                        ~  RL 9 XQQ4 3UB~eQ=
                      -ILJOJLJR        ~'aw~    ~B- 0 Summary                          NDE Number    Com  onent            Exam          Results 601560    MSU-55                VT-3  No Recordable Indications.
Mechanical Snubber          Temperature: 109 F.
Serial  Number:            Setting:  1 5/8" 18195                          Acceptable.
Model PSA-3 601570    MSU-57                VT-3  No  Recordable Indications.
Mechanical Snubber          Insignificant:    No  tag-Accept.
Serial  Number:            Temperature:    138 F.
15388                        Setting:  2 1/4" Model PSA-3                    Acceptable.
1 II
 
23 Summary Number
          'Ma'n Com n:
                      ~Stea onent
                              ~Loo A'    Inch NDE Exam
                                              ~Rise s
                                              ~Dawin v
B-9 Results 601580          MSU-58                VT-3  No Recordable Indications.
Mechanical Snubber            Temperature: 170 F.
Serial  Number:              Setting:  2 1/4" 18187                          Acceptable.
Model PSA-3 601590          MSU-60                VT-3  No  Recordable Indications.
Mechanical Snubber            Insignificant: Corrosion Serial 18186 Number:              from pipeline above Temperature: 169 F.
it  -Accept.
Model PSA-3                  Setting: 3"  Acceptable.
24
                                              @raw~    C-32
        'ummary NDE Number          Com  onent            Exam          Results 601600          MSU-72                VT-3  No  Recordable Indications.
Mechanical Snubber            Temperature: 140 F.
Serial  Number:              Setting:  2 1/2" 15767                          Acceptable.
Model PSA-3 601610          MSU-74                VT-3  No Recordable Indications.
Mechanical Snubber            Temperature: 335 F.
Serial  Number:              Setting:  3 1/4" 10083                            Acceptable.
Model PSA-10 601620          MSU-75                VT-3  No  Recordable Indications.
Mechanical Snubber            Temperature: 334 F.
Serial  Number:              Setting: 1,7/8" 8030                            Acceptable.
Model PSA-10
                                              ~Dw~in  ~C-Summary                                NDE Number          Com  onent            Exam          Results 601630          MSU-78                VT-3  No  Recordable Indications.
Mechanical Snubber            Temperature: 220 F.
Serial  Number:              Setting: 3" 8576                            Acceptable.
Model PSA-10
 
Summary                          NDE Number    Com  onent            Exam            Results 601640    MSU-80                VT-3    No  Recordable Indications.
Mechanical Snubber            Temperature: 220 F.
Serial  Number:                Setting:  2 1/8" 18181                            Acceptable.
Model PSA-3 601650    MSU-82                VT-3    No  Recordable Indications.
Mechanical Snubber            Temperature: 220 F.
Serial  Number:                Setting:  2 3/4" 15768                            Acceptable.
Model PSA-3 601659    MSU-84 (EAST)          VT-3    No  Recordable Indications.
Mechanical Snubber            Temperature: 72 F.
Serial  Number:                Setting:  3 1/8" 18182                            Acceptable.
Model PSA-3 601660    MSU-84 (WEST)          VT-3    No  Recordable Indications.
Mechanical Snubber            Temperature: 72 F.
Serial  Number:                Setting:  2 5/8" 18183                            Acceptable.
Model PSA-3 601670    MSU-85                VT-3    No  Recordable Indications.
Mechanical Snubber            Temperature: 284 F.
Serial  Number:                Setting:  3 3/8" 10074                            Acceptable.
Model PSA-10
: 25. ~w ~e~s      ~Sa et        ct'o
          ~L'~ ~A~0                      ~Daw~
Summary                          NDE Number                          Exam            Results 601680    RHU-8                  VT-3    No  Recordable Indications.
Mechanical Snubber            Temperature: 61 F.
Serial  Number:                Setting:  2 5/8" 15755                            Acceptable.
Model PSA-3 II
'l+
l~
: 26. ~R sidual Heat Removal:
          ~i~ 10A-A 7-250          ~raw'n: ~15 Summary                        NDE Number                        Exam          Results 601690    RHU-30              VT-3 No Recordable Indications.
Mechanical Snubber        Temperature: 61 F.
Serial  Number:          Setting:  1" 7065                          Acceptable.
Model PSA-35 601700    RHU-33              VT-3 No  Recordable Mechanical Snubber                        61 F.
Indications'emperature:
Serial  Number:          Setting:  3 1/8" 7064                        Acceptable.
Model PSA-35
                  -*              ~Dr  win:  B-23 Summary                        NDE Number    Com  onent          Exam          Results 601710    RHU-36              VT-3 No Recordable Indications.
Mechanical Snubber        Temperature: 64 F.
Serial  Number:          Setting:  2  1/2" 15756                        Acceptable.
Model PSA-3 Summary                        NDE Number    Com  onent          Exam          Results 601720    RHU-51              VT-3 No  Recordable Indications.
Mechanical Snubber        Temperature: 76 F, Serial  Number:          Setting:  2 1/2" 15752                        Acceptable.
Model PSA-3 601730    RHU-53              VT-3 No  Recordable Indications.
Mechanical Snubber        Temperature: 74 F, Serial  Number:          Setting:  2  3/4",
15754                        Acceptable.
Model PSA-3 p
        ~ice:  6D-AC-601          ~Draw'n: B-26 Summary                      NDE Number  Com  onent          Exam          Results 601740  RHU-61              VT-3  No  Recordable Indications.
Mechanical Snubber        Temperature: 79 F.
Serial  Number:            Setting:  2 3/8" 15753                        Acceptable.
Model PSA-3 Summary                      NDE Number  Com  onent          Exam          Results 601749  RHU-63 (NORTH)      VT-3  No  Recordable Indications.
Mechanical Snubber        Temperature: 64 F.
Serial  Number:          -Setting:  2 3/4" 16380                        Acceptable.
Model PSA-1 601750  RHU-63 (SOUTH)      VT-3  No  Recordable Indications.
Mechanical Snubber        Insignificant: Mortar under Serial  Number:            mounting plate is cracked.
16375                      Acceptable per NCR 90-118, Model PSA-1                A.G. Goetz. Temperature:    64 F.
Setting: 3"  Acceptable.
                                  ~Draw'    'B-Summary                      NDE Number  Com  onent          Exam          Results 601760  RHU-69              VT-3  No Recordable Indications.
Mechanical Snubber        Temperature: 65 F.
Serial  Number:            Setting:  2 1/4" 8629                          Acceptable.
Model PSA-10 601769  RHU-71 (NORTH)      VT-3  No  Recordable Indications.
Mechanical Snubber        Temperature: 63 F.
Serial  Number:            Setting:  2 1/2" 11466                        Acceptable.
Model PSA-1 601770  RHU-71 (SOUTH)      VT-3  No  Recordabl'e Indications.
Mechanical Snubber        Temperature: 63 F.
Serial  Number:            Setting:  2 1/2" 11465                        Acceptable.
Model PSA-1
  ~E 1
~
4 ~t
 
27
                                              ~Dw~in: Q-20 NDE
            'ummary Number              Com  onent          Exam        Results 601780              RHU-72              VT-3 No  Recordable  Indications.
Mechanical Snubber        Temperature:    63 F.
Serial  Number:          Setting:  3" 8606                        Acceptable, Model PSA-10
: 28. Residual ~Hat geqjova~
                                              ~D~awi >~ Q-20 Summary                                  NDE Number              Com  onent          Exam        Results 601790              RHU-75              VT-3 No Recordable Indications.
Mechanical Snubber        Temperature: 63 F.
Serial  Number:          Setting:  3  1/2" 8632                        Acceptable.
Model PSA-10
                                              +raw in@:  ~B-2 Summary                                  NDE Number              Com  onent          Exam        Results 601800              RHU-92              VT-3 No  Recordable Indications.
Mechanical Snubber        Insignificant: Light rust Serial  Number:          on base  plate. Accept.
16376-                    Temperature:    63 F.
Model PSA-1              Setting:  2  1/4" -Acceptable.
29
                                              ~Dew ln:  ~B-1
          'ummary NDE
~em be r            Com  onent          Exam        Results-601810              RHU-109              VT-3 No  Recordable Indications.
Mechanical Snubber        Temperature: 79 F.
Serial  Number:          Setting:  2 1/4" 11463                      Acceptable.
Model PSA-1 I
~ )
1 t
 
Summary                        NDE Number  Com  onent,            Exam            Results 601820  RHU-110                VT-3  No    Recordable Indications.
Mechanical Snubber            Temperature: 74 F.
Serial  Number:                Setting:    2 1/4" 16373                              Acceptable.
Model PSA-1 Line:  ~S-30                  ~Dr aw  ': ~1~6 Summary                        NDE Number  Com  onent              Exam            Results 601830  RHU-119                VT-3  No  'Recordable Indications.
Mechanical Snubber            Temperature: 140 F.
Serial  Number:                Setting:    1 5/8" 15766                              Acceptable.
Model PSA-3
                                      ~Drawin: 1i-19 Summary                        NDE Number  Com  onent              Exam            Results 601840  RHU-123                VT-3  No    Recordable Indications.
Mechanical Snubber            Temperature: 89 F, Serial  Number:                Setting:    2 1/2" 15765                            Acceptable.
Model PSA-3 Line:  10    2-250          ~Draw Summary                        NDE Number  Com  onent              Exam            Results 601850  SIU-3                  VT-3  No    Recordable Indications.
Mechanical Snubber            Temperature: 57 F.
Serial  Number:                Setting: 3.250" 8614                              Acceptable.
Model PSA-10
        ~L'ne:      -S 2- 50          ~Dawin:    ~6 Summary                        -NDE Number  Com  onent              Exam            Results 601860  SIU-47                  VT                                        Reject: Snubber tang binding Mechanical Snubber            on pipe clamp. Repaired under Serial  Number:                NCR 90-187. No Recordable 15349                          Indications, Acceptable.
Model PSA-3                    Temperature: 72 F.
Setting: 3 3/8" -Acceptable.
r'g 0,
g I
: 30. Resi1Lnn,'Bat removal:
                                          ~D~wi~n: A-14 Summary                              NDE Exam          Results 601870    SIU-52                    VT-3  No  Recordable Indications.
Mechanical Snubber              Temperature: 69 F.
Serial  Number:                Setting:  2 9/16" 15348                              Acceptable.
Model PSA-3 31 ~ e ':            1 6    1ll' ma w                              ~Dawin: C-13 Summary                              NDE Number                              Exam          Results 601890    SWU-254                  VT-3  Rejected: Loose nuts on west Mechanical Snubber              side of snubber pipe clamp.
Serial  Number:                Repaired under NCR 90-208.
12508                          Temperature: 42 F.
Model PSA 1/2                  Setting:  1  1/8" -Acceptable.
                                          ~Drawin: C-14 Summary                              NDE Number                              Exam          Results 601900    SWU-308                  VT-3  No  Recordable Indications.
Mechanical Snubber              Temperature: 49 F.
Serial  Number:                Setting:  2  3/4".
8031                              Acceptable.
Model PSA-10
                              ~'la.
601910    SWU-309                  VT-3  No  Recordable Indications.
Mechanical Snubber              Temperature: 49 F.
Serial  Number:                Setting:  3 1/4" 10073                              Acceptable.
Model PSA-10 32 '                  -      ~                    a-'      e- w Penetrat'on  ~31  -32
                                          ~DawiDR:  ~C-  6B Summary                              NDE Number                              Exam          Results 601920    SWU-370                  VT-3  No  Recordable Indications.
Mechanical Snubber                  Temperature: 45 F, Serial  Number:                      Setting:  2  1/4" 11464                                Acceptable.
Model PSA-1 "J
7.
 
33
                                          ~D~w'~n: C-24
        'ummary NDE Number          Corn  onent        Exam        Results 601930          AFU-205 (AFW-10)    VT-3 No Recordable Indications.
Hydraulic Snubber        Temperature: 81 F.
Serial    Number:        Setting: 3" 12900                      Acceptable.
Model    Grinnell Size  1  1/2 Fight AFU-208    (AFW-13) VT-3 Reject: Cold setting 2 1/16" 601940 Hydraulic Snubber        should be 3 1/2". NCR 90-109 Serial    Number:        generated. Gilbert Scales show 21010                    proper setting to be 2 1/2".
Model    Grinnell        Revise ME-256      Use-as-is per
                                    ~f 8r.
200              E.K. Voce Temperature: 66 F.
Setting: 2 1/16" -Acceptable.
: 34.        IL  M        '
                                          +raw~    C-20 Summary                              NDE Number          Com  onent        Exam        Results 601950          AFW-25              VT-3 Other: This snubber has been Hydraulic'nubber        removed from the line under seismic upgrade program phase
: 10. Removed from Snubber program.
601960          AFW-26              VT-3 Other: This snubber has been Hydraulic Snubber        removed from the line under seismic upgrade program phase
: 10. Removed from Snubber program.
601970          AFU-226 (AFW-27)    VT-3 No  Recordable Indications.
Hydraulic Snubber        Temperature: 86 F.
Serial    Number:        Setting:  3  1/8" 12901                      Acceptable.
Model    Grinnell Size  1  1/2 601980          AFU-224 (AFW-28)    VT-3 No  Recordable Indications, Hydraulic Snubber        Temperature: 86 F.
Serial    Number:        Setting:  2 1/2" 12905                      Acceptable.
Model    Grinnell Size  1  1/2
 
0 4
r
 
Summary                          NDE Number    Com  onent            Exam        Results 601990    AFU-225 (AFW-29)      VT-3 No Recordable Indications.
Hydraulic Snubber          Temperature: 85 F.
Serial  Number:            Setting:  1 3/4" 12906                        Acceptable.
Model  Grinnell Size  1  1/2 602000    AFU-227 (AFW-31)      VT-3 No Recordable Indications.
Mechanical Snubber          Temperature: 69 F.
        '"'l Serial  Number:            Setting:  4 1/4" 25594                          Acceptable.
Model PSA-3 35                  'I'L
                                      ~Drawin  S-2 Summary                          NDE Number    Com  onent            Exam        Results 602010    N601                  VT-3 Reject: Snubber hits base Hydraulic Snubber          plate at wall has no ID tag.
8D Serial  Number:            NCR 90-184 generated.        Base 6565                        plate does    not    impair function.
Model Grinnel              Use-as-is per E.K. Voci. New Size  2                    ID tag installed. Temperature:
66 F., Setting: 3" -Acceptable.
602020    N602                  VT-3 Reject: No ID tag. NCR 90-184 Hydraulic Snubber          generated, ID tag installed.
Serial  Number:            Temperature: 66 F.
6568                        Setting: 2 1/4" Model  Grinnell              Acceptable.
Size  2 Summary                          NDE
                                      ~aw~      ~S-Number                          ,Exam        Results 602030    N604                  VT-3 Reject:  No    ID tag. NCR  90-184 Hydraulic Snubber          generated. ID tag    installed.
Serial  Number:            Temperature:    66 F.
6566                        Setting:  1  1/2" Model  Grinnell            Acceptable.
Size  2 602040    N605                  VT-3 No  Recordable Indications.
Hydraulic Snubber          Temperature: 66 F.
Serial  Number:            Setting:  2 3/4" 6561                          Acceptable.
Model  Grinnell Size  2 ch g,l
 
Summary                                NDE Number          Com  onent            Exam          Results 602050          N607                  VT-3  Reject: No ID tag. NCR 90-184 Hydraulic Snubber          generated. ID tag installed.
Serial    Number:          Temperature: 66 F.
6562                        Setting: 3 1/2" Model    Grinnell            Acceptable.
Size  2 602060          N608                  VT-3  Reject: Snubber has    no ID  tag 5, Hydraulic Snubber          hits  base  plate. NCR  90-184 Serial    Number:          generated. The Snubber hitting 6563                        base plate does not impair its Model    Grinnell          function. Use-as-is per E.K.
Size  2                    Voci. New ID tag installed.
Temperature:    66 F.
Setting:  3  3/4" -Acceptable.
                                            /raw~      S-2 Summary                                NDE Number          Com  onent            Exam          Results 602070          N615                  VT-3  Reject:  No  ID tag. NCR  90-184 Hydraulic Snubber          generated. ID tag installed.
Serial    Number:          Temperature: 64 F.
6564                      Setting: 2 3/8" Model    Grinnell            Acceptable.
Size  2 Qrawirri: S-2 Summary                                NDE Number          Com  onent            Exam          Results 602080          N616                  VT-3  Reject: Cotter key broken off Hydraulic Snubber          at top near wall, no ID tag.
Serial    Number:          NCR 90-184 generated. Key 6567                        repaired R ID tag installed.
Model    Grinnell          Temperature: 65 F.
Size  2                    Setting: 2 5/8" -Acceptable.
36              :2
                                  '&'DE        awi~
Exam'D
        'ummary Number                                              Results 602090          PS-2                  VT-3  No Recordable Indications.
Hydraulic Snubber          Temperature: 63 F.
Serial    Number:          Setting: 4" PD872-39-1244                Acceptable.
Model Paul Monroe  PMH2103
'h 45
 
Summary                        NDE Number    Corn onent            Exam        Results 602100    PS-4                  VT-3 No  Recordable Indications.
Hydraulic Snubber          Temperature: 63 F.
Serial  Number:            Setting:  1" PD86144-1152                  Acceptable.
Model Paul Monroe. PMH 2103
                                    ~Draw in: S-1 Summary                        NDE Number    Com  onent            Exam        Results 602110    PS-5                  VT-3 Reject: Cotter key at top not Hydraulic Snubber          engaged 100K    8c deformed. NCR Serial  Number:            90-112'enerated for repairs.
PD87767-1246              Re-examined    after repairs.
Model                      Temperature:    65 F.
Paul Monroe    PMH 2103  Setting:  2  5/8" -Acc'eptable.
602120    PS-6                  VT-3 Reject: Broken cotter key/lack Hydraulic Snubber          of thread engagement at clamp Serial  Number:            end. NCR 90-112 generated.
PD87767-1239              Re-examined    after repairs.
Model                      Insignificant: Lack of thread Paul Monroe -PMH 2103      engagement acceptable per design analysis by W. Tomo.
602130  . PS-8                  VT-3 No  Recordable Indications.
Hydraulic Snubber          Temperature: 65 F, .
Serial  Number:            Setting:  2 3/4" 86144-1159                    Acceptable.
Model Paul Monroe  PMH  2103 602140    PS-9                  VT-3 No  Recordable Indications.
Hydraulic Snubber          Temperature: 65 F.
Seri'al Number:            Setting:  3" 86144-1154                  Acceptable.
Model Paul Monroe  PMH  2103 602150    PS-10                VT-3 No Recordable Indications.
Hydraulic Snubber          Temperature: 66 F.
Serial  Number:            Setting:  3  5/8" 86144-1157                  Acceptable.
Model Paul Monroe  PMH  2103 T
                                          ~rawin:    S-1A Summary                          NDE Number    Com  onent            Exam                Results 602160    PS-11                  VT-3      No  Recordable Indications.
Hydraulic. Snubber                Temperature: 65 F.
Serial  Number:                  Setting: 2 5/16" PD86144-1156                        Acceptable.
Model Paul Monroe    PMH 2103 H. SNUBBER PROGRAM FUNCTIONAL TESTING:
                                    ~Draw ':    ~A-Summary                          NDE Number    Com  onent            Exam                Results 600081    SGA-7                  FT        Functionally tested    and Hydraulic Snubber                acceptable.
2 ~
                                        ~Dawin Summary                        NDE Number                          Exam                Results 600341    AFU-103 (EAST)        FT        Functionally tested    and Mechanical Snubber                acceptable.
Serial  Number:
18184 Model PSA-3 600342    AFU-103 (WEST)        FT        Functionally tested    and Mechanical Snubber                acceptable.
Serial  Number:
18185 Model PSA-3
                                        /raw~i'C-Summary                        NDE Number    Com onent            Exam                Results 600361    AFU-109                FT        Functionally tested    S/N Hydraulic Snubber                15403. Installed new snubber Serial  Number:                  S/N 30986  acceptable.
30986 Size 1.5
 
1 Summary                        NDE Exam              Results 600381  AFU-111                FT        Functionally tested  and Mechanical Snubber                acceptable.
Serial  Number:
16377 Model PSA-1
: 3. Reactor coolant ~P  m    1B ~Sea    Water:
                                          ~Dr  w'n:  B-33 Summary                        NDE Exam              Results 600961  CVU-103                FT        Functionally tested  and Mechanical Snubber                acceptable.
Serial  Number:
24450 Model PSA-1 Functionally tested
                                                          '00981 CVU-104                FT                              and Mechanical Snubber                acceptable.
Serial  Number:
24449 Model PSA-1
: 4. CWCS  ~Ltdow
                                        ~Dr  win:  B-35 Summary                        NDE Number  Com  onent            Exam              Results 601041  CVU-345                FT        Functionally tested  and Mechanical Snubber                acceptable.
Serial  Number:
9491 Model PSA 1/2
                                        ~D. awi~    gE-5 Summary                        NDE Exam              Results 601171  FWU-20                FT        Functionally tested  and Mechanical Snubber                acceptable.
Serial  Number:
7049 Model PSA-35 w"p
          ~L'ne: 14-B- W-900-19      ~Dewin: HB-8 Summary                          NDE Number                          Exam          Results 601291    FWU-48                FT    Functionally tested and Mechanical Snubber          acceptable.
Serial  Number:
7475 Model PSA-35 601301    FWU-51                FT    Functionally tested and Mechanical Snubber          acceptable.
Serial  Number:
7483 Model PSA-35
: 7. Residual geea, ~eoval:
                                      ~awi~n    B-20 Summary                          NDE Exam          Results 601761    RHU-69                FT    Functionally tested and Mechanical Snubber          acceptable.
Serial  Number:
8679 Model PSA-10
          @iLne:  0 -S 2-2 0        ~Daw:Lnn Summary                          NDE
                                              'esults Exam 601861  'IU-47                  FT    Functionally tested and Mechanical Snubber          acceptable, Serial  Number:
15349 Model PSA-3 if '
ff4
 
9 ~        Service  ~Wate    to  A & Q    ~D'esel Generator Water Coolers:
                                                            ~Drswin: 0-13 Summary                                        NDE Number            Com  onent                Exam                Results
'601891            SWU-254                    FT          Functionally tested and Mechanical Snubber                      acceptable.
Serial  Number:
12508 Model  PSA  1/2 10  ~                              l'                    s g Steam Generator Feedwater              ~~e ~
I '"                                    ~rawin  '-20 Summary                                        NDE Number            Com  onent                Exam                Results 602001            AFU-227 (AFW-31)            FT          Functional test not required Mechanical Snubber                      on this snubber in 1990.
Serial  Number:                        Snubber AFU-109 was 25594                                    substituted per G. Wahl.
Model PSA-3 I' 'U              '
                                                          ~raw  n:
u~
                                                                      'S-2
                                                                            ~
Summary                                      NDE Number            Com  onent                Exam                Results 602041            N605                        FT          Functionally tested and Hydraulic Snubber                        acceptable.
Serial  Number:
6561 Model  Grinnell, Size        2 12          ~Powe  P e    u
                                            ~R~eg,'DE Qg~w'~n:    ~S-1
          'ummary Number            Com  onent                Exam                Results 602161            PS-11                      FT          Functionally tested and Hydraulic Snubber                        acceptable.
Serial Number:
PD86144-1156 Model Paul Monroe      PMH  2103 qi'
*kg
/'
 
GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990  1999  Interval, First Outage 1990 Attachment II Erosion/Corrosion (Minwall)  Summary  Report This section provides a detailed listing of components and associated examination results on items that were inspected during the 1990 Ginna Outage. A total of 312 components were examined.
Chart number 1 shows by graphic display the types of components that were examined. This chart also provides an overall display of
,components in relationship to the percentage of nominal wall remaining. Out of a total number of 312 components; 17 components had less than 65X nominal wall remaining.
Table number 1 provides a complete listing of items by components that were examined during the 1990 Ginna Outage.      If  the listed component had examination results in 1989, the results of that, examination is specified along with the results of the 1990 inspection. The percentage of Nominal Wall remaining by component is also included for reference.
1990  Minwall Examination Program and Results:
The following listing identifies the systems,      the types of components within the system, the examination      result  breakdown as a percentage of nominal wall remaining as well      as the  reference drawing that identifies the component within      the specified system.
Drawing                    System
~o.                        +ice M-1        A/B Feedwater Pump Discharge to  5  A/B Heater.
Results:
2 Pipes                      1  >88X    of nominal 1  88-82X of nominal M-4B        Feedwater Cleanup to Condenser East Wall.
Results:
4 Elbows                    1  >88X    of  nominal 2 Pipes                      2  88-82X  of  nominal 2 Reducers                  1  82-76X  of  nominal 4  76-70X  of  nominal Heaters  4 A/B to Feedwater Suction.
Results:
2 Elbows                    3  >88X    of nominal 2 Pipes                      2  88-82X  of nominal 1 Tee
 
~
'lMf p "1
 
Drawing                  System No.                      Title M-7B    Condensate Pump h Heater Drain Tank Discharge to Feedwater Suction.
Results:
1  Elbow                        6  >88X      of nominal 3  Pipes 2  Tees M-10    Low  Pressure  Downcomers.
Results:
1  Pipe                        1  76-70X    of nominal M-10A    Low  Pressure  Downcomers  in  West Condenser.
Results:
5  Elbows                      6  >88X      of nominal 17  Pipes                      10  88-82X of nominal 2  82-76X of nominal 2  76-70X of nominal 2  <65X      of nominal M-10B    Low  Pressure Downcomers in East Condenser.
Results:
7  Pipes                        5  88-82%    of nominal 1  82-76X    of nominal 1  <65X      of nominal M-11A  .MSR  lA,  1B 2nd Pass  Drain.
Results:
2  Elbows                      3  >88X      of nominal 2  Pipes                        1  88-82X of nominal M-11B    MSR  2A, 2B 2nd Pass  Drain.
Results:
1  Pipe                        1  >88X      of nominal 2  Tees                        2  88-82X    of nominal M-12A    MSR  1A, 1B 2nd Pass  Drain to  5A H.P.H.  &  Condenser.
Com  onents Examined:            Results:
2  Elbows                      3  >88X      of nominal 3  Pipes                        1  88-82X    of nominal 1  Tee                          1  82-76X    of nominal 1  76-70X    of nominal M-12B    MSR  2A,. 2B 2nd Pass Drain  to  5B H.P.H. k,  Condenser.
Results:
2  Elbows                      4  >88X      of nominal 3  Pipes                        1  88-82X of nominal 2  Reducers                    3  82-76X o'f nominal 1  Tee
 
A l
j1 0
+l
 
System
                  ~T'ie MSR 1A    4th Pass to 5A Heater.
Results:
2  Elbows                      1  >88X    of nominal 1  88-82X  of nominal MSR 1B    4th Pass to  GB Heater.
Results:
2  Elbows                      1  >88X    of nominal 1  88-82%'of nominal MSR 1A & 1B    4th Pass to Condenser.
Results:
2  Elbows                      2  88-82X  of nominal MSR 2A    4th Pass to  GA Heater.
Results:
1  Elbow                      1  >88X    of nominal MSR 2B    4th Pass to  GB Heater.
Results:
2  Elbows                      2  >88X    of nominal 1  Pipe                        1  88'-82X of nominal MSR 2A    &. 2B 4th Pass to Condenser.
Results:
5  Elbows                      8  >88X    of nominal 5  Pipes                      4  88-82X  of nominal 2  Tees 1A, 2A & 3A L.P.H. Drains      to Condenser.
Results:
2  Elbows                      3  >88X    of nominal 3  Reducers                    1  88-82X  of nominal 1  82-76X  of nominal Steam    Extraction to Preseparator    B & 4B  L.P.HE Results:
10 Elbows                      11  >88X    of nominal 9  Pipes                      3  88-82X of nominal 1  Reducer                    1  82-76X of nominal 1  Tee                        4  76-70X of nominal 1  Downcomer  (pipe)          1  70-65X of nominal 2  <65%    of nominal
 
P fE J
 
Drawing                  System NcC,                      ~T'~e M-22    Steam  Extraction to Preseparator    A  Sc 4A  L.P.H.
Results:
5 Elbows                      4  88-82X      of nominal 4 Pipes                        3  82-76X      of nominal 1 Reducer                      2  76-70X      of nominal 1 Tee                          3  <65X        of nominal 1 Downcomer    (pipe)
M-27    Condensate    Booster  Pumps to Hydrogen Coolers.
Results:
1 Elbow                        1  >88%        of nominal 1 Pipe                        1  82-76X of nominal M-28    Condensate    Booster  Pumps to Hydrogen Coolers.
Results:
1 Elbow                        1    >88X      of nominal M-31    MSR 1A & 1B    to Heater Drain Tank.
Results:
2 Elbows                      2  >88X        of nominal 1 Tee                          1  88-82X      of nominal M-32    MSR 2A  8r. 2B  to Heater Drain Tank.
Results:
5 Elbows                      9  >88X        of nominal 3 Pipes 1 Reducer M-41A  5A  H.P.H. Drain to 4A L.P.H.
1 Reducer                      1  >88X        of nominal M-41B  GB  H.P.H. Drain to 4B L.P.H.
1 Elbow                        2  >88X        of nominal 1 Pipe M-45    Preseparator    A/B to Heater Drain Tank    &,  Condenser.
Results:
1 Pipe                        1  76-70X      of nominal M-46A  Preseparator    A/B to Heater Drain Tank    8r, Condenser.
Results:
1 Elbow                          82-76X      of nominal
 
e.
System Title Preseparator  A/B to Heater Drain Tank.
Results:
1 Pipe                        3 >88X  of nominal 2 Reducers Turbine Driven Auxiliary Feedwater Pump to Discharge Lines.
Results:
5 Elbows                      7 >88X  of nominal 3 Pipes                        2 88-82X of nominal 1 Tee Auxiliary Feedwater    Pump A  to Discharge Lines.
Results:
2 Elbows                      3 >88X  of nominal 1 Pipe Auxiliary Feedwater    Pump B  to Discharge Lines.
Results:
1 Pipe                        1 >88X  of nominal Steam  Extraction to  5A Sc 5B H.PoH.
Results:
1 Elbow                        5 >88X  of nominal 4 Pipes                      2  88-82X of nominal 2 Reducers                    4  <65X  of nominal 2 Tees 2 Nozzles Feedwater Discharge,    Turbine Building.
Results:
1 Reducer                      1 76-70X of nominal Steam Generator Blowdown    Lines, (Intermediate Building)
Results:
7 Elbows                      6  >88X  of  nominal 7 Pipes                      2  88-82X of  nominal 4  76-70X of  nominal 1 70-65X of  nominal 1 <65X  of  nominal Steam Generator Blowdown    Lines, (Turbine Building)
Results:
4 Elbows                      8  >88X  of nominal 6 Pipes                      2  88-82X of nominal 1 Lateral                    1  <65X  of nominal
 
dk wt II~
I I
I'I t
 
Drawing                System goo.                  /itic M-89A  Steam Generator  1A Blowdown Lines, (Containment Building)
Results:
6 Pipes                  10    >88X  of nominal 3 Tees 1 Nozzle, M-89B  Steam Generator  1B Blowdown Lines, (Containment Building)
Results:
4 Pipes                    3  >88X  of nominal 1 Tee                      2  88-82X of nominal M-89C  Steam Generator  1B Blowdowm Lines (Containment Building)
Results:
1 Elbow                    3  >88X  of nominal 3 Pipes                    2  88-82X of nominal 2 Tees                      1  82-76X of nominal M-90    Feedwater Recirculation (CV-10).
Results:
1 Pipe                      1  70-65X of nominal Feedwater Recirculation (CV-19),
Results:
1 Elbow                    1  70-65X of nominal M-92    Main Feedwater Pump Bypass.
Results:
2 Elbows                    1  >88X  of nominal 1  76-70X of nominal M-94    Steam Generator Blowdoun  to Condenser.
Results:
8 Elbows                  15    >88X  of nominal 10 Pipes              Housel'esults:
3  88-82X of nominal M-SW    Service Water in Screen 8 Elbows                  21    >88X  of nominal 15 Pipes                    6  88-82X of nominal 4 Tees N/A    Heater Drain Tank to Condenser.
Summary Numbers 400001 to 400002 Results:
2 Elbows                    2  >88X  of nominal


Summary Number Com onent NDE Exam Results 601330 FWU-57 Mechanical Snubber Serial Number: 10064 Model PSA-10 VT-3 No Recordable Indications.
l Drawing                  System
Temperature:
~o ~                      Tii]e IP N/A    Main Steam Dump    to Condenser.
187 F.Setting: 2.875"-Acceptable.
Summary Numbers 400003    to 400004 Results:
19.Maia Steam~Loo~A~Draw': B-8 Summary Number Com onent NDE Exam Results 601350 MSU-2 Mechanical Snubber Serial Number: 7048 Model PSA-35 VT-3 No Recordable Indications.
2 Reducers                    2  >88X    of nominal N/A    Blowdown Tank to Condenser.
Temperature:
Summary Numbers 400005 to 400006 Results:
68 F.Setting: 3 1/4" Acceptable.
1 Elbow                        2  >88X    of nominal 1  Pipe N/A    Blowdown Tank to 3A Low Pressure Heater.
601360 MSU-3 Mechanical Snubber Serial Number: 7060 Model PSA-35 VT-3 No Recordable Indications.
Summary Numbers 400007 to 400008 Results:
Temperature:
1  Elbow                        2  >88X    of nominal 1  Pipe N/A    Gland Steam Discharge to Gland Steam Condenser.
67 F.Setting: 3" Acceptable.
Su'mmary Numbers 400009    to 400010 Com  onents Examined:           Results:
20'a'n~Si~aa~~Loo B:~aw~in'-8 Summary Number Com onent NDE Exam Results 601369 MSU-7 (TOP)Mechanical Snubber Serial Number: 7051 Model PSA-35 VT-3 No Recordable Indications.
1  Elbow                        2  >88X    of nominal 1  Lateral N/A    Preseparator    Drain to Preseparator Vent.
Insi,gnificant:
Summary Numbers 400011    to 400015 Results:
No damage is apparent to snubber or rear brackets.Total movement is significant
1  Elbow                        4  >88X    of nominal 3 Pipes                        1  <65X    of nominal' Tee N/A     4B Low Pressure Heater    Vent.
-2".Drag force present.Temperature:
Summary Numbers 400016    to 400025 Results:
80 F.Setting: 2 3/4".Acceptable to ME-256 per A.Butcavage.
3 Elbows                      9  >88X    of nominal 5  Pipes 1  Tee N/A    Steam  Extraction To 4A Low Pressure      Heater.
601370 MSU-7 (BOTTOM)Mechanical Snubber Serial Number: 7047 Model PSA-35 VT-3-48-No Recordable Indications.
Summary Numbers 400047 to 400058 Results:
Insignificant:
12  Pipes                        6  76-70X  of nominal 4  70-65X  of nominal 2  <65X    of nominal
No damage to snubber.Present movement 2".Drag force present.Temperature:
80 F., Setting: 3".Acceptable to ME-256 per A.Butcavage.


Summary Number Com onent NDE Exam Results 601380 MSU-8 Hydraulic Snubber Serial Number: G-20968-1-30 Model HSSA-20 VT-3 No Recordable Indications.
kt 9 1 ebl
Insignificant:
Snubber does not, move by hand.Temperature:
100 F., Setting 3 1/2",-Acceptable.
Summary Number 3-B-S-6 0-1B Com onent NDE Exam~Draw'~n'B-1 0 Results 601390 MSU-12 Mechanical Snubber Serial Number: 9400 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Pigeon feces.Acceptable per NCR 90-119.Temperature:
190 F.Setting: 3.375"-Acceptable.
601399 MSU-13 (EAST)Mechanical Snubber Serial Number: 1467 Model PSA-100 VT-3 No Recordable Indications.
Insignificant:
Pigeon feces.Acceptable per NCR 90-119.Temperature:
200 F.Setting: 3.25"-Acceptable.
601400 MSU-13 (WEST)Mechanical Snubber Serial Number: 1464 Model PSA-100 VT-3 No Recordable Indications.
Insignificant:
Pigeon feces, Acceptable per NCR 90-119.Temperature:
200 F.Setting: 3.25"-Acceptable.
601409 MSU-15 (NORTH)Mechanical Snubber Serial Number: 7476 Model PSA-35 VT-3 No Recordable Indications, Insignificant:
Light rust;Does not rotate-acceptable.
Temperature:
48 F., Setting: 3" Acceptable.
601410 MSU-15 (SOUTH)Mechanical Snubber Serial Number: 7477 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Light rust.Does not rotate, acceptable.
Temperature:
48 F., Setting: 3 1/4">-Acceptable.
601419 MSU-16 (NORTH)Mechanical Snubber Serial Number: 7481 Model PSA-35 VT-3-49-No Recordable Indications.
Insignificant:
Pigeon feces.Acceptable per NCR 90-119.Temperature:
190 F., Setting: 3.875"-Acceptable.
IP 4.s'I, 4i P Summary Number 1 601420 Com onent MSU-16 (SOUTH)Mechanical Snubber Serial Number: 7480 Model PSA-35 NDE Exam VT-3~Drawin: B-10 Results No Recordable Indications.
Insignificant:
Pigeon feces.Acceptable per NCR 90-119.Temperature:
205 F.Setting: 4.375"-Acceptable.
601429 MSU-18 (NORTH)Mechanical Snubber Serial Number: 93695 1645 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Pigeon feces.Acceptable per NCR 90-119.Temperature:
180 F., Setting: 3.625"-Acceptable.
601430 MSU-18 (SOUTH)Mechanical Snubber Serial Number: 937251646 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Pigeon feces.Acceptable per NCR 90-119.Temperature:
160 F.Setting: 3.375"-Acceptable.
601439 MSU-19 (NORTH)Mechanical Snubber Serial Number: 9369 Model PSA'-35 VT-3 No Recordable Indications.
Insignificant:
Light rust.Does not rotate.Acceptable.
Temperature:
325 F.Setting: 4.25"-Acceptable.
601440 MSU-19 (SOUTH)Mechanical Snubber Serial Number: 9372 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Light rust.Does not rotate.Accept.Temperature:
235 F.Setting: 4.25"-Acceptable.
601450 MSU-22 Mechanical Snubber Serial Number: 9357 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Light rust'.Does not rotate.Accept.Temperature:
235 F.Setting: 4.375"-Acceptable.
601460 MSU-25 Mechanical Snubber Serial Number: 1465 Model PSA-100 VT-3-50-No Recordable Indications.
Insignificant:
Light rust.Does not rotate.Accept.Temperature:
"235 F.Setting: 4.125"-Acceptable.
I Summary NDE Exam Results 601469 MSU-26 (TOP)Mechanical Snubber Serial Number: 1465 Model PSA-100 VT-3 No Recordable Indications.
Insignificant:
Light rust.Does not rotate.Accept.Temperature:
235 F., Setting: 4.125",-Acceptable.
601470 MSU-26 (BOTTOM)Mechanical Snubber Serial Number: 9389 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Light rust on attachment plate to pipe.Temperature:
235 F., Setting: 1.5" ,-Acceptable.
601480 MSU-27 Mechanical Snubber Serial Number: 9398 Model PSA-35 VT-3 No Recordable Indications.
Insignificant:
Light rust.Does not rotate.Accept.Temperature:
235 F., Setting: 4.5",-Acceptable.
601490 MSU-29 Mechanical Snubber Serial Number: 1469 Model PSA-100 VT-3 No Recordable Indications Insignificant:
Does not rotate.Accept.Temperature:
416 F., Setting: 4 1/8" Acceptable.
601500 MSU-31 Mechanical Snubber Serial Number: 9356 Model PSA-35 VT-3 No Recordable Indications.
Temperature:
416 F.Setting: 2 5/8" Acceptable.
601510 MSU-32 Mechanical Snubber Serial Number: 1093 Model PSA-100 VT-3 No Recordable Indications.
Temperature:
292 F.Setting: 2 1/2" Acceptable.
/J' 21~Summary Number~Ma'n~St.ea~Lo A: Com onent NDE Exam~awi~n: B-9 Results 601520 601530 MSU-38 Mechanical Snubber Serial Number: 1090 Model PSA-100 MSU-39 Mechanical Snubber Serial Number: 1087 Model PSA-100 VT-3 VT-3 Reject: Snubber installed backward to print.NCR 90-101.Snubber may be installed 180 deg.without change of function.Use-as-is.
per E.K.Voci.-Acceptable.
No Recordable Indications.
Insignificant:
Does not rotate.Accept.Temperature:
76 F.Setting: 4 3/4"-Acceptable.
601540 MSU-40 Mechanical Snubber Serial Number: 1080 Model PSA-100 VT-3 No Recordable Indications.
Insignificant:
Does not rotate.Accept.Temperature:
416 F.Setting: 4 5/8"-Acceptable.
601550 MSU-44 Mechanical Snubber Serial Number: 1468 Model PSA-100 VT-3 No Recordable Indications.
Insignificant:
Does not rotate.No ID tag.Accept.Temperature:
416 F.Setting: 3 1/8"-Acceptable.
22'KQX$<CKR~RL 9 XQQ4 3UB~eQ=Summary Number a'-ILJOJLJR Com onent NDE Exam~'aw~~B-0 Results 601560 601570 MSU-55 Mechanical Snubber Serial Number: 18195 Model PSA-3 MSU-57 Mechanical Snubber Serial Number: 15388 Model PSA-3 VT-3 VT-3 No Recordable Indications.
Temperature:
109 F.Setting: 1 5/8" Acceptable.
No Recordable Indications.
Insignificant:
No tag-Accept.
Temperature:
138 F.Setting: 2 1/4"-Acceptable.
$1 II 23'Ma'n~Stea~Loo A'Inch~Rise s v Summary Number n: Com onent NDE Exam~Dawin B-9 Results 601580 MSU-58 Mechanical Snubber Serial Number: 18187 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
170 F.Setting: 2 1/4"-Acceptable.
601590 MSU-60 Mechanical Snubber Serial Number: 18186 Model PSA-3 VT-3 No Recordable Indications.
Insignificant:
Corrosion from pipeline above it-Accept.Temperature:
169 F.Setting: 3"-Acceptable.
24'ummary Number Com onent NDE Exam@raw~C-32 Results 601600 MSU-72 Mechanical Snubber Serial Number: 15767 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
140 F.Setting: 2 1/2"-Acceptable.
601610 MSU-74 Mechanical Snubber Serial Number: 10083 Model PSA-10 VT-3 No Recordable Indications.
Temperature:
335 F.Setting: 3 1/4" Acceptable.
601620 MSU-75 Mechanical Snubber Serial Number: 8030 Model PSA-10 VT-3 No Recordable Indications.
Temperature:
334 F.Setting: 1,7/8" Acceptable.
Summary Number Com onent NDE Exam~Dw~in~C-Results 601630 VT-3 MSU-78 Mechanical Snubber Serial Number: 8576 Model PSA-10-53-No Recordable Indications.
Temperature:
220 F.Setting: 3" Acceptable.


Summary Number Com onent NDE Exam Results 601640 MSU-80 Mechanical Snubber Serial Number: 18181 Model PSA-3 VT-3 No Recordable Indications.
Component Respectable   Dispositions:
Temperature:
220 F.Setting: 2 1/8"-Acceptable.
601650 MSU-82 Mechanical Snubber Serial Number: 15768 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
220 F.Setting: 2 3/4" Acceptable.
601659 MSU-84 (EAST)Mechanical Snubber Serial Number: 18182 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
72 F.Setting: 3 1/8"-Acceptable.
601660 MSU-84 (WEST)VT-3 Mechanical Snubber Serial Number: 18183 Model PSA-3 No Recordable Indications.
Temperature:
72 F.Setting: 2 5/8"-Acceptable.
601670 MSU-85 Mechanical Snubber Serial Number: 10074 Model PSA-10 VT-3 No Recordable Indications.
Temperature:
284 F.Setting: 3 3/8" Acceptable.
25.~w~e~s~Sa et~L'~~A~0 ct'o~Daw~Summary Number 601680 RHU-8 Mechanical Snubber Serial Number: 15755 Model PSA-3 NDE Exam VT-3 Results No Recordable Indications.
Temperature:
61 F.Setting: 2 5/8" Acceptable.
II'l+l~
26.Summary Number~R sidual Heat Removal:~i~10A-A 7-250 NDE Exam~raw'n:~15 Results 601690 RHU-30 Mechanical Snubber Serial Number: 7065 Model PSA-35 VT-3 No Recordable Indications.
Temperature:
61 F.Setting: 1" Acceptable.
601700 RHU-33 Mechanical Snubber Serial Number: 7064 Model PSA-35 VT-3 No Recordable Indications'emperature:
61 F.Setting: 3 1/8"-Acceptable.
Summary Number 601710-*Com onent RHU-36 Mechanical Snubber Serial Number: 15756 Model PSA-3 NDE Exam VT-3~Dr win: B-23 Results No Recordable Indications.
Temperature:
64 F.Setting: 2 1/2" Acceptable.
Summary Number Com onent NDE Exam Results 601720 RHU-51 Mechanical Snubber Serial Number: 15752 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
76 F, Setting: 2 1/2"-Acceptable.
601730 RHU-53 Mechanical Snubber Serial Number: 15754 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
74 F, Setting: 2 3/4", Acceptable.
p Summary Number~ice: 6D-AC-601 Com onent NDE Exam~Draw'n: B-26 Results 601740 RHU-61 Mechanical Snubber Serial Number: 15753 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
79 F.Setting: 2 3/8"-Acceptable.
Summary Number Com onent NDE Exam Results 601749 601750 RHU-63 (NORTH)Mechanical Snubber Serial Number: 16380 Model PSA-1 RHU-63 (SOUTH)Mechanical Snubber Serial Number: 16375 Model PSA-1 VT-3 VT-3 No Recordable Indications.
Temperature:
64 F.-Setting: 2 3/4" Acceptable.
No Recordable Indications.
Insignificant:
Mortar under mounting plate is cracked.Acceptable per NCR 90-118, A.G.Goetz.Temperature:
64 F.Setting: 3"-Acceptable.
Summary Number Com onent NDE Exam~Draw''B-Results 601760 RHU-69 Mechanical Snubber Serial Number: 8629 Model PSA-10 VT-3 No Recordable Indications.
Temperature:
65 F.Setting: 2 1/4" Acceptable.
601769 RHU-71 (NORTH)Mechanical Snubber Serial Number: 11466 Model PSA-1 VT-3 No Recordable Indications.
Temperature:
63 F.Setting: 2 1/2"-Acceptable.
601770 RHU-71 (SOUTH)Mechanical Snubber Serial Number: 11465 Model PSA-1 VT-3 No Recordabl'e Indications.
Temperature:
63 F.Setting: 2 1/2" Acceptable.
~E 1~4~t 27'ummary Number Com onent NDE Exam~Dw~in: Q-20 Results 601780 RHU-72 Mechanical Snubber Serial Number: 8606 Model PSA-10 VT-3 No Recordable Indications.
Temperature:
63 F.Setting: 3"-Acceptable, 28.Residual~Hat geqjova~~D~awi>~Q-20 Summary Number 601790 Com onent RHU-75 Mechanical Snubber Serial Number: 8632 Model PSA-10 NDE Exam VT-3 Results No Recordable Indications.
Temperature:
63 F.Setting: 3 1/2"-Acceptable.
Summary Number 601800 Com onent RHU-92 Mechanical Snubber Serial Number: 16376-Model PSA-1 NDE Exam VT-3+raw in@:~B-2 Results No Recordable Indications.
Insignificant:
Light rust on base plate.Accept.Temperature:
63 F.Setting: 2 1/4"-Acceptable.
29'ummary~em be r 601810 Com onent RHU-109 Mechanical Snubber Serial Number: 11463 Model PSA-1 NDE Exam VT-3-57-~Dewln:~B-1 Results-No Recordable Indications.
Temperature:
79 F.Setting: 2 1/4"-Acceptable.
I~)1 t Summary Number Com onent, NDE Exam Results 601820 RHU-110 Mechanical Snubber Serial Number: 16373 Model PSA-1 VT-3 No Recordable Indications.
Temperature:
74 F.Setting: 2 1/4" Acceptable.
Summary Number Line:~S-30 Com onent NDE Exam~Dr aw':~1~6 Results 601830 RHU-119 Mechanical Snubber Serial Number: 15766 Model PSA-3 VT-3 No'Recordable Indications.
Temperature:
140 F.Setting: 1 5/8" Acceptable.
Summary Number Com onent NDE Exam~Drawin: 1i-19 Results 601840 RHU-123 Mechanical Snubber Serial Number: 15765 Model PSA-3 VT-3 No Recordable Indications.
Temperature:
89 F, Setting: 2 1/2" Acceptable.
Summary Number 601850 Line: 10-2-250 Com onent SIU-3 Mechanical Snubber Serial Number: 8614 Model PSA-10 NDE Exam VT-3~Draw'Results No Recordable Indications.
Temperature:
57 F.Setting: 3.250" Acceptable.
Summary Number~L'ne:-S 2-50 Com onent-NDE Exam~Dawin:~6 Results 601860 SIU-47 Mechanical Snubber Serial Number: 15349 Model PSA-3 VT-3-58--Reject: Snubber tang binding on pipe clamp.Repaired under NCR 90-187.No Recordable Indications, Acceptable.
Temperature:
72 F.Setting: 3 3/8"-Acceptable.
r'g g 0, I 30.Resi1Lnn,'Bat removal:~D~wi~n: A-14 Summary 601870 SIU-52 Mechanical Snubber Serial Number: 15348 Model PSA-3 NDE Exam VT-3 Results No Recordable Indications.
Temperature:
69 F.Setting: 2 9/16" Acceptable.
31~e': 1-6-1ll'ma Summary Number 601890 w SWU-254 Mechanical Snubber Serial Number: 12508 Model PSA 1/2 NDE Exam VT-3~Dawin: C-13 Results Rejected: Loose nuts on west side of snubber pipe clamp.Repaired under NCR 90-208.Temperature:
42 F.Setting: 1 1/8"-Acceptable.
Summary Number 601900 SWU-308 Mechanical Snubber Serial Number: 8031 Model PSA-10 NDE Exam VT-3~Drawin: C-14 Results No Recordable Indications.
Temperature:
49 F.Setting: 2 3/4".Acceptable.
601910 SWU-309 Mechanical Snubber Serial Number: 10073 Model PSA-10 VT-3 No Recordable Indications.
Temperature:
49 F.Setting: 3 1/4" Acceptable.
32'-~~'la.a-'e-w Penetrat'on
~31-32~DawiDR:~C-6B Summary Number 601920 SWU-370 Mechanical Snubber Serial Number: 11464 Model PSA-1 NDE Exam VT-3-59-Results No Recordable Indications.
Temperature:
45 F, Setting: 2 1/4" Acceptable.
"J 7.
33'ummary Number 601930 601940 Corn onent AFU-205 (AFW-10)Hydraulic Snubber Serial Number: 12900 Model Grinnell Size 1 1/2 AFU-208 (AFW-13)Hydraulic Snubber Serial Number: 21010 Model Grinnell Fight 200 NDE Exam VT-3 VT-3~D~w'~n: C-24 Results No Recordable Indications.
Temperature:
81 F.Setting: 3" Acceptable.
Reject: Cold setting 2 1/16" should be 3 1/2".NCR 90-109 generated.
Gilbert Scales show proper setting to be 2 1/2".Revise ME-256 8r.Use-as-is per E.K.Voce Temperature:
66 F.Setting: 2 1/16"-Acceptable.
34.IL M'~f Summary Number Com onent NDE Exam+raw~C-20 Results 601950 601960 601970 601980 AFW-25 Hydraulic'nubber AFW-26 Hydraulic Snubber AFU-226 (AFW-27)Hydraulic Snubber Serial Number: 12901 Model Grinnell Size 1 1/2 AFU-224 (AFW-28)Hydraulic Snubber Serial Number: 12905 Model Grinnell Size 1 1/2 VT-3 VT-3 VT-3 VT-3 Other: This snubber has been removed from the line under seismic upgrade program phase 10.Removed from Snubber program.Other: This snubber has been removed from the line under seismic upgrade program phase 10.Removed from Snubber program.No Recordable Indications.
Temperature:
86 F.Setting: 3 1/8"-Acceptable.
No Recordable Indications, Temperature:
86 F.Setting: 2 1/2" Acceptable.
0 4 r Summary Number 601990 602000 Com onent AFU-225 (AFW-29)Hydraulic Snubber Serial Number: 12906 Model Grinnell Size 1 1/2 AFU-227 (AFW-31)Mechanical Snubber Serial Number: 25594 Model PSA-3 NDE Exam VT-3 VT-3 Results No Recordable Indications.
Temperature:
85 F.Setting: 1 3/4"-Acceptable.
No Recordable Indications.
Temperature:
69 F.Setting: 4 1/4" Acceptable.
35'"'l'I'L-~Drawin S-2 Summary Number Com onent NDE Exam Results 602010 602020 N601 Hydraulic Snubber Serial Number: 6565 Model Grinnel Size 2 N602 Hydraulic Snubber Serial Number: 6568 Model Grinnell Size 2 VT-3 VT-3 Reject: Snubber hits base plate at wall 8D has no ID tag.NCR 90-184 generated.
Base plate does not impair function.Use-as-is per E.K.Voci.New ID tag installed.
Temperature:
66 F., Setting: 3"-Acceptable.
Reject: No ID tag.NCR 90-184 generated, ID tag installed.
Temperature:
66 F.Setting: 2 1/4" Acceptable.
Summary Number 602030 N604 Hydraulic Snubber Serial Number: 6566 Model Grinnell Size 2 NDE ,Exam VT-3~aw~~S-Results Reject: No ID tag.NCR 90-184 generated.
ID tag installed.
Temperature:
66 F.Setting: 1 1/2"-Acceptable.
602040 N605 Hydraulic Snubber Serial Number: 6561 Model Grinnell Size 2 VT-3-61-No Recordable Indications.
Temperature:
66 F.Setting: 2 3/4" Acceptable.
ch g,l Summary Number Com onent NDE Exam Results 602050 N607 Hydraulic Snubber Serial Number: 6562 Model Grinnell Size 2 VT-3 Reject: No ID tag.NCR 90-184 generated.
ID tag installed.
Temperature:
66 F.Setting: 3 1/2"-Acceptable.
602060 N608 Hydraulic Snubber Serial Number: 6563 Model Grinnell Size 2 VT-3 Reject: Snubber has no ID tag 5, hits base plate.NCR 90-184 generated.
The Snubber hitting base plate does not impair its function.Use-as-is per E.K.Voci.New ID tag installed.
Temperature:
66 F.Setting: 3 3/4"-Acceptable.
/raw~S-2 Summary Number Com onent NDE Exam Results 602070 N615 Hydraulic Snubber Serial Number: 6564 Model Grinnell Size 2 VT-3 Reject: No ID tag.NCR 90-184 generated.
ID tag installed.
Temperature:
64 F.Setting: 2 3/8"-Acceptable.
Summary Number 602080 Com onent N616 Hydraulic Snubber Serial Number: 6567 Model Grinnell Size 2 NDE Exam VT-3 Qrawirri: S-2 Results Reject: Cotter key broken off at top near wall, no ID tag.NCR 90-184 generated.
Key repaired R ID tag installed.
Temperature:
65 F.Setting: 2 5/8"-Acceptable.
36'ummary Number:2'&'DE Exam'D awi~Results 602090 PS-2 VT-3 Hydraulic Snubber Serial Number: PD872-39-1244 Model Paul Monroe-PMH2103-62-No Recordable Indications.
Temperature:
63 F.Setting: 4"-Acceptable.
'h 45 Summary Number Corn onent NDE Exam Results 602100 PS-4 VT-3 Hydraulic Snubber Serial Number: PD86144-1152 Model Paul Monroe.-PMH 2103 No Recordable Indications.
Temperature:
63 F.Setting: 1" Acceptable.
~Draw in: S-1 Summary Number Com onent NDE Exam Results 602110 PS-5 VT-3 Hydraulic Snubber Serial Number: PD87767-1246 Model Paul Monroe-PMH 2103 Reject: Cotter key at top not engaged 100K 8c deformed.NCR 90-112'enerated for repairs.Re-examined after repairs.Temperature:
65 F.Setting: 2 5/8"-Acc'eptable.
602120 PS-6 VT-3 Hydraulic Snubber Serial Number: PD87767-1239 Model Paul Monroe-PMH 2103 Reject: Broken cotter key/lack of thread engagement at clamp end.NCR 90-112 generated.
Re-examined after repairs.Insignificant:
Lack of thread engagement acceptable per design analysis by W.Tomo.602130.VT-3 PS-8 Hydraulic Snubber Serial Number: 86144-1159 Model Paul Monroe-PMH 2103 No Recordable Indications.
Temperature:
65 F,.Setting: 2 3/4" Acceptable.
602140 VT-3 PS-9 Hydraulic Snubber Seri'al Number: 86144-1154 Model Paul Monroe-PMH 2103 No Recordable Indications.
Temperature:
65 F.Setting: 3"-Acceptable.
602150 PS-10 VT-3 Hydraulic Snubber Serial Number: 86144-1157 Model Paul Monroe-PMH 2103 No Recordable Indications.
Temperature:
66 F.Setting: 3 5/8"-Acceptable.
T Summary Number Com onent NDE Exam~rawin: S-1A Results 602160 VT-3 PS-11 Hydraulic.
Snubber Serial Number: PD86144-1156 Model Paul Monroe-PMH 2103 No Recordable Indications.
Temperature:
65 F.Setting: 2 5/16"-Acceptable.
H.SNUBBER PROGRAM FUNCTIONAL TESTING:~Draw':~A-Summary Number Com onent NDE Exam Results 600081 SGA-7 Hydraulic Snubber FT Functionally tested and acceptable.
2~Summary Number 600341 600342 AFU-103 (EAST)Mechanical Snubber Serial Number: 18184 Model PSA-3 AFU-103 (WEST)Mechanical Snubber Serial Number: 18185 Model PSA-3 NDE Exam FT FT~Dawin Results Functionally tested and acceptable.
Functionally tested and acceptable.
Summary Number Com onent NDE Exam/raw~i'C-Results 600361 AFU-109 Hydraulic Snubber Serial Number: 30986 Size 1.5 FT Functionally tested S/N 15403.Installed new snubber S/N 30986-acceptable. .
1 Summary NDE Exam Results 600381 AFU-111 Mechanical Snubber Serial Number: 16377 Model PSA-1 FT Functionally tested and acceptable.
3.Reactor coolant~P m 1B~Sea Water:~Dr w'n: B-33 Summary NDE Exam Results 600961 CVU-103 Mechanical Snubber Serial Number: 24450 Model PSA-1 FT Functionally tested and acceptable.
'00981 CVU-104 Mechanical Snubber Serial Number: 24449 Model PSA-1 FT Functionally tested and acceptable.
4.CWCS~Ltdow~Dr win: B-35 Summary Number 601041 Com onent CVU-345 Mechanical Snubber Serial Number: 9491 Model PSA 1/2 NDE Exam FT Results Functionally tested and acceptable.
Summary NDE Exam~D.awi~gE-5 Results 601171 FWU-20 Mechanical Snubber Serial Number: 7049 Model PSA-35 FT-65-Functionally tested and acceptable.
w"p Summary Number 601291~L'ne: 14-B-W-900-19 NDE Exam FWU-48 FT Mechanical Snubber Serial Number: 7475 Model PSA-35~Dewin: HB-8 Results Functionally tested and acceptable.
601301 FWU-51 Mechanical Snubber Serial Number: 7483 Model PSA-35 FT Functionally tested and acceptable.
7.Residual geea,~eoval:~awi~n B-20 Summary 601761 RHU-69 Mechanical Snubber Serial Number: 8679 Model PSA-10 NDE Exam FT Results Functionally tested and acceptable.
Summary@iLne: 0-S 2-2 0 NDE Exam~Daw:Lnn'esults 601861'IU-47 Mechanical Snubber Serial Number: 15349 Model PSA-3 FT Functionally tested and acceptable, if'ff4 9~Service~Wate to A&Q~D'esel Generator Water Coolers:~Drswin: 0-13 Summary Number Com onent NDE Exam Results'601891 SWU-254 Mechanical Snubber Serial Number: 12508 Model PSA 1/2 FT Functionally tested and acceptable.
10~l's g Steam Generator Feedwater~~e~I'"~rawin'-20 Summary Number Com onent NDE Exam Results 602001 AFU-227 (AFW-31)FT Mechanical Snubber Serial Number: 25594 Model PSA-3 Functional test not required on this snubber in 1990.Snubber AFU-109 was substituted per G.Wahl.I'-'U'u~~~raw n: 'S-2 Summary Number Com onent NDE Exam Results 602041 N605 FT Hydraulic Snubber Serial Number: 6561 Model Grinnell, Size 2 Functionally tested and acceptable.
12'ummary Number~Powe P e u Com onent~R~eg,'DE Exam Qg~w'~n:~S-1 Results 602161 FT-67-PS-11 Hydraulic Snubber Serial Number: PD86144-1156 Model Paul Monroe-PMH 2103 Functionally tested and acceptable.
qi'*kg/'
GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990-1999 Interval, First Outage 1990 Attachment II Erosion/Corrosion (Minwall)Summary Report This section provides a detailed listing of components and associated examination results on items that were inspected during the 1990 Ginna Outage.A total of 312 components were examined.Chart number 1 shows by graphic display the types of components that were examined.This chart also provides an overall display of ,components in relationship to the percentage of nominal wall remaining.
Out of a total number of 312 components; 17 components had less than 65X nominal wall remaining.
Table number 1 provides a complete listing of items by components that were examined during the 1990 Ginna Outage.If the listed component had examination results in 1989, the results of that, examination is specified along with the results of the 1990 inspection.
The percentage of Nominal Wall remaining by component is also included for reference.
1990 Minwall Examination Program and Results: The following listing identifies the systems, the types of components within the system, the examination result breakdown as a percentage of nominal wall remaining as well as the reference drawing that identifies the component within the specified system.Drawing~o.System+ice M-1 A/B Feedwater Pump Discharge to 5 A/B Heater.Results: 2 Pipes 1>88X of nominal 1 88-82X of nominal M-4B Feedwater Cleanup to 4 Elbows 2 Pipes 2 Reducers Condenser East Wall.Results: 1>88X of nominal 2 88-82X of nominal 1 82-76X of nominal 4 76-70X of nominal Heaters 4 A/B to Feedwater Suction.Results: 2 Elbows 3>88X of nominal 2 Pipes 2 88-82X of nominal 1 Tee
~f'lM p"1 Drawing No.System Title M-7B Results: 6>88X of nominal Condensate Pump h Heater Drain Tank Discharge to Feedwater Suction.1 Elbow 3 Pipes 2 Tees M-10 Low Pressure Downcomers.
1 Pipe Results: 1 76-70X of nominal M-10A Low Pressure Downcomers in West Condenser.
Results: 5 Elbows 6>88X of 17 Pipes 10 88-82X of 2 82-76X of 2 76-70X of 2<65X of nominal nominal nominal nominal nominal M-10B Low Pressure Downcomers in East Condenser.
Results: 7 Pipes 5 88-82%of nominal 1 82-76X of nominal 1<65X of nominal M-11A.MSR lA, 1B 2nd Pass Drain.2 Elbows 2 Pipes Results: 3>88X of nominal 1 88-82X of nominal M-11B MSR 2A, 2B 2nd Pass Drain.1 Pipe 2 Tees Results: 1>88X of nominal 2 88-82X of nominal M-12A MSR 1A, 1B 2nd Pass Drain Com onents Examined: 2 Elbows 3 Pipes 1 Tee to 5A H.P.H.&Condenser.
Results: 3>88X of nominal 1 88-82X of nominal 1 82-76X of nominal 1 76-70X of nominal M-12B MSR 2A,.2B 2nd Pass Drain 2 Elbows 3 Pipes 2 Reducers 1 Tee to 5B H.P.H.k, Condenser.
Results: 4>88X of nominal 1 88-82X of nominal 3 82-76X o'f nominal A j1 l 0+l System~T'ie MSR 1A 4th Pass to 5A Heater.Results: 2 Elbows 1>88X of nominal 1 88-82X of nominal MSR 1B 4th Pass to GB Heater.Results: 2 Elbows 1>88X of nominal 1 88-82%'of nominal MSR 1A&1B 4th Pass to Condenser.
Results: 2 Elbows 2 88-82X of nominal MSR 2A 4th Pass to GA Heater.Results: 1 Elbow 1>88X of nominal MSR 2B 4th Pass to GB Heater.Results: 2 Elbows 2>88X of nominal 1 Pipe 1 88'-82X of nominal MSR 2A&.2B 4th Pass to Condenser.
Results: 5 Elbows 8>88X of nominal 5 Pipes 4 88-82X of nominal 2 Tees 1A, 2A&3A L.P.H.Drains to Condenser.
Results: 2 Elbows 3>88X of nominal 3 Reducers 1 88-82X of nominal 1 82-76X of nominal Steam Extraction to Preseparator B&4B Results: 10 Elbows 11>88X 9 Pipes 3 88-82X 1 Reducer 1 82-76X 1 Tee 4 76-70X 1 Downcomer (pipe)1 70-65X 2<65%L.P.HE of nominal of nominal of nominal of nominal of nominal of nominal P fE J Drawing NcC, M-22 System~T'~e Steam Extraction to Preseparator A Sc 4A Results: 5 Elbows 4 88-82X 4 Pipes 3 82-76X 1 Reducer 2 76-70X 1 Tee 3<65X 1 Downcomer (pipe)L.P.H.of nominal of nominal of nominal of nominal M-27 Condensate Booster Pumps to Hydrogen Coolers.Results: 1 Elbow 1>88%of nominal 1 Pipe 1 82-76X of nominal M-28 Condensate Booster Pumps to Hydrogen Coolers.Results: 1 Elbow 1>88X of nominal M-31 MSR 1A&1B to Heater Drain Tank.Results: 2 Elbows 2>88X of nominal 1 Tee 1 88-82X of nominal M-32 MSR 2A 8r.2B to Heater Drain Tank.Results: 5 Elbows 9>88X 3 Pipes 1 Reducer of nominal M-41A 5A H.P.H.Drain to 4A L.P.H.1 Reducer 1>88X of nominal M-41B GB H.P.H.Drain to 4B L.P.H.1 Elbow 2>88X 1 Pipe of nominal M-45 Preseparator A/B to Heater Drain Tank&, Condenser.
Results: 1 Pipe 1 76-70X of nominal M-46A Preseparator A/B to Heater Drain Tank 8r, Condenser.
Results: 1 Elbow 82-76X of nominal
: e.
System Title Preseparator A/B to Heater Drain Tank.Results: 1 Pipe 3>88X 2 Reducers of nominal Results: 7>88X of nominal 2 88-82X of nominal Turbine Driven Auxiliary Feedwater Pump to Discharge Lines.5 Elbows 3 Pipes 1 Tee Auxiliary Feedwater Pump A to Discharge Lines.Results: 2 Elbows 3>88X of nominal 1 Pipe Auxiliary Feedwater Pump B to Discharge Lines.Results: 1 Pipe 1>88X of nominal Steam Extraction to 5A Sc 1 Elbow 4 Pipes 2 Reducers 2 Tees 2 Nozzles 5B H.PoH.Results: 5>88X of nominal 2 88-82X of nominal 4<65X of nominal Feedwater Discharge, Turbine Building.Results: 1 Reducer 1 76-70X of nominal Steam Generator Blowdown Lines, (Intermediate Building)Results: 7 Elbows 6>88X of nominal 7 Pipes 2 88-82X of nominal 4 76-70X of nominal 1 70-65X of nominal 1<65X of nominal Steam Generator Blowdown 4 Elbows 6 Pipes 1 Lateral Lines, (Turbine Building)Results: 8>88X of nominal 2 88-82X of nominal 1<65X of nominal dk wt II~I I I'I t Drawing goo.M-89A System/itic Steam Generator 1A Blowdown Lines, (Containment Building)Results: 6 Pipes 10>88X of nominal 3 Tees 1 Nozzle, M-89B Steam Generator 1B Blowdown Lines, (Containment Building)Results: 4 Pipes 3>88X of nominal 1 Tee 2 88-82X of nominal M-89C Steam Generator 1B Blowdowm 1 Elbow 3 Pipes 2 Tees Lines (Containment Building)Results: 3>88X of nominal 2 88-82X of nominal 1 82-76X of nominalM-90 Feedwater Recirculation (CV-10).Results: 1 Pipe 1 70-65X of nominal Feedwater Recirculation (CV-19), Results: 1 Elbow 1 70-65X of nominal M-92 Main Feedwater Pump Bypass.Results: 2 Elbows 1>88X of nominal 1 76-70X of nominal M-94 Steam Generator Blowdoun to Condenser.
Results: 8 Elbows 15>88X of nominal 10 Pipes 3 88-82X of nominal M-SW Service Water in Screen Housel'esults:
8 Elbows 21>88X of nominal 15 Pipes 6 88-82X of nominal 4 TeesN/A Heater Drain Tank to Condenser.
Summary Numbers 400001 to 400002 Results: 2 Elbows 2>88X of nominal l
Drawing~o~N/A System Tii]e IP Main Steam Dump to Condenser.
Summary Numbers 400003 to 400004 Results: 2 Reducers 2>88X of nominal N/A Blowdown Tank to Condenser.
Summary Numbers 400005 to 400006 Results: 1 Elbow 2>88X 1 Pipe of nominal N/A Blowdown Tank to 3A Low Pressure Heater.Summary Numbers 400007 to 400008 Results: 1 Elbow 2>88X 1 Pipe of nominal N/A Gland Steam Discharge to Gland Steam Condenser.
Su'mmary Numbers 400009 to 400010 Com onents Examined: Results: 1 Elbow 2>88X of nominal 1 Lateral N/A Preseparator Drain to Preseparator Vent.Summary Numbers 400011 to 400015 Results: 1 Elbow 4>88X of nominal 3 Pipes 1<65X of nominal'Tee N/A 4B Low Pressure Heater Vent.Summary Numbers 400016 to 400025 Results: 3 Elbows 9>88X 5 Pipes 1 Tee of nominal N/A Steam Extraction To 4A Low Pressure Heater.Summary Numbers 400047 to 400058 Results: 12 Pipes 6 76-70X of nominal 4 70-65X of nominal 2<65X of nominal kt9 1 ebl Component Respectable Dispositions:
The following listing of Dispositions provides information on components that have less than 70X of Nominal Wall remaining.
The following listing of Dispositions provides information on components that have less than 70X of Nominal Wall remaining.
f~s.em: Low Pressure Downcomers in West Condenser.
f~s.em:   Low Pressure Downcomers in West Condenser.
Component Summar No.212180 Dwg.ID No.No.NCR No.M-10A 18 90-143 Dis osit.ion Engineering Evaluation,"use-as-is", Reexamine during 1992 outage.212190 M-10A 19 90-143 Engineering Evaluation,"use-as-is", Reexamine during 1992 outage.~S t~e~Low Pressure Downcomers in East Condenser.
Component       Dwg. ID Summar   No. No.     No. NCR No.     Dis osit.ion 212180          M-10A   18     90-143       Engineering Evaluation, "use-as-is",     Reexamine during   1992 outage.
Component Dwg.ID Summar No.No.No.NCR No.213060 M-10B 2F 90-142 Dis osition Engineering Evaluation,"use-as-is", Reexamine during 1992 outage.~S stem: Feedwater Recirculation (CV-18)~Component Dwg.Summar No.No.ID No.NCR No.Dis osition 300440 M-90 43 89-312 No change since last exam during 1989 outage.~a~t n: Feedwater Recirculation (CV-19), Component Dwg.ID Summar No, No.No.NCR No.Dis osition 300840 M-91 38 89-279 No change since last exam during 1989 outage.~tern: Steam Extraction to Preseparator B&, 4B L.P.H.-301300 M-21 28 Component Dwg.ID Summar No.No.No.301270 M-21 25 301290'-21 27 NCR No.90-128 90-128 90-128 Dis osition Component was Replaced.Component, was Replaced.Engineering Evaluation, use&s is~
212190         M-10A   19     90-143       Engineering Evaluation, "use-as-is",     Reexamine during   1992 outage.
N Dis ositi:on'ngineering Evaluation, II II use-as-is~S st~Steam Extraction to Preseparator A&4A L.P.H.Component Dwg.ID 302010 M-22 28 90-131 302020 M-22 29 90-131 First 20" of component was Replaced.302130.M-22 38 90-131 Component was Replaced.~S can'team Extraction to 5A&, 5B H.P.H.Component Dwg.Summar No.No.303015 M-75 ID No.NCR No.1A 90-168 Dis osition Component was Replaced.303017 M-75 1B N/A Component was"pad welded" from I.D.when downstream component was Replaced.303165 303167 M-75 M-75 16A 90-168 16B N/A Component was Replaced.Component was"pad welded" from I.D.when downstream component was Replaced.~S i~taa Steam Generator Blowdown Lines, (Intermediate Building)Component Dwg.Summar No.No.304425 M-88A ID No.NCR No.2A 90-150 Dis osition Adjacent fillet welds were reworked to give a concave shape to reduce stresses.304435 M-88A 3A 90-150 Adjacent, fillet welds were reworked to give a concave shape to reduce stresses.Qgg~terg: Steam Generator Blowdown Lines, (Turbine Building)Component Dwg.Summar No.No.385800 M-88D ID No.NCR No.80 90-215 Dis osition Welded rolled plate to O.D.~i~m'reseparator Drain to Preseparator Vent.Component Dwg.Summar No.No.400014 N/A ID No.NCR No.N/A 90-216 Dis osition Engineering Evaluation, II tt use-as-is  
~S   t~e~   Low Pressure Downcomers in East   Condenser.
Component       Dwg. ID Summar   No. No.     No. NCR No.     Dis osition 213060         M-10B   2F     90-142       Engineering Evaluation, "use-as-is",     Reexamine during   1992 outage.
~S stem:   Feedwater Recirculation (CV-18)   ~
Component       Dwg. ID Summar   No. No.     No. NCR No.     Dis   osition 300440         M-90     43     89-312       No   change since   last exam during   1989 outage.
~a~t   n: Feedwater Recirculation (CV-19),
Component       Dwg. ID Summar     No,   No.     No. NCR No.     Dis   osition 300840         M-91     38     89-279       No   change since   last exam during   1989 outage.
~tern:     Steam Extraction to Preseparator     B &, 4B L.P.H.
Component       Dwg. ID Summar     No. No.     No. NCR  No.      Dis  osition 301270           M-21     25     90-128        Component was Replaced.
301290       '-21         27     90-128       Component, was Replaced.
-301300          M-21    28    90-128        Engineering Evaluation, use &s   is ~
 
N
~S st~     Steam Extraction to Preseparator     A & 4A   L.P.H.
Component       Dwg. ID Dis ositi:on 302010         M-22   28     90-131       'ngineering        Evaluation, II use-as-is  II 302020         M-22   29     90-131       First   20"   of component   was Replaced.
302130.       M-22   38     90-131       Component was Replaced.
~S   can'team Extraction to   5A &, 5B H.P.H.
Component       Dwg. ID Summar   No. No. No. NCR No.     Dis    osition 303015        M-75    1A     90-168       Component was Replaced.
303017         M-75   1B     N/A           Component     was "pad welded" from I.D. when downstream component was Replaced.
303165         M-75   16A   90-168       Component was Replaced.
303167        M-75    16B   N/A           Component was "pad welded" from I.D. when downstream component was Replaced.
~S i~taa Steam Generator Blowdown   Lines, (Intermediate Building)
Component       Dwg. ID Summar   No. No. No. NCR No.     Dis osition 304425          M-88A  2A     90-150       Adjacent fillet welds were reworked to give a concave shape to reduce stresses.
304435         M-88A   3A     90-150       Adjacent,     fillet   welds were reworked to give a concave shape to reduce stresses.
Qgg~terg: Steam Generator Blowdown   Lines, (Turbine Building)
Component       Dwg. ID Summar   No. No. No. NCR No.     Dis    osition 385800          M-88D  80     90-215       Welded   rolled plate to     O.D.
~i~m'reseparator         Drain to Preseparator     Vent.
Component       Dwg. ID Summar   No. No. No. NCR No.      Dis osition 400014         N/A    N/A   90-216        Engineering        Evaluation, II use-as-is  tt
 
~t~      Steam  Extraction To 4A Low  Pressure Heater.
Component      Dwg. ID Summar  No. No. No. NCR No.     Dis osition 400051        N/A    5      90-131        Engineering    Evaluation, ft use-as-is It 400053        N/A           90-131    'ngineering        Evaluation, "use-as-is".
400054        N/A            90-131        Engineering Evaluation, "use-as-is",.
400056        N/A            90-131        Engineering Evaluation, "use-as-is".
400057        N/A            90-131        Engineering Evaluation, "use-as-is".
400058        N/A    A      90-131        Engineering Evaluation, "use-as-is".
I1 l\
W
}
~ .
 
MlNWALL                                              MINWALL 1990 GINNA OUTAGE                                    1990 GINNA OUTAGE 154 160                                                  200 180 140 120              108                                150 100 80                                                  100 64 60 40                        28                        50 19                                              27 16                  17 20 0                                                    0 PIPES  ELBOV/S    TEES    REDUCERS NOZZLES          >88%  88-82% 82-76% 76-70% 70-65%  >65%
NUhSER OF EACH OOMPONENT TYPE                            PERCENTAGE OF NOMINAL THAT WAS EXAMNED                                        WALL REhWNING Chart I
 
J IP I


~t~Steam Extraction To 4A Low Pressure Heater.Component Dwg.Summar No.No.400051 N/A ID No.NCR No.5 90-131 Dis osition Engineering Evaluation, ft use-as-is It 400053 N/A 90-131'ngineering Evaluation,"use-as-is".
Page No.
400054 N/A 90-131 Engineering Evaluation,"use-as-is",.
05/15/90
400056 N/A 90-131 Engineering Evaluation,"use-as-is".
400057 N/A 90-131 Engineering Evaluation,"use-as-is".
400058 N/A A 90-131 Engineering Evaluation,"use-as-is".
I 1 l\}W~.
MlNWALL 1990 GINNA OUTAGE MINWALL 1990 GINNA OUTAGE 160 154 200 180 140 120 108 150 100 80 100 60 64 40 20 28 19 50 16 27 17 0 PIPES ELBOV/S TEES REDUCERS NOZZLES NUhSER OF EACH OOMPONENT TYPE THAT WAS EXAMNED 0 Chart I>88%88-82%82-76%76-70%70-65%>65%PERCENTAGE OF NOMINAL WALL REhWNING J IP I Page No.05/15/90  


==SUMMARY==
==SUMMARY==
COMP TYPE 1989 MIN.1990 MIN.NUMBER NO.READING READING PERCENT NOMINAL**DRAWING NUMBER M-1 200010 1 P 0.602 200015 1A P 0.534 0.595 0.669 88-82>88"*DRAWING NUMBER 204510 51'204520 52 E 204570 57 E 204590 59 E 204600 60 P 204610 61 E 204630 63 R 204840'4 P**DRAWING NUMBER 205040 4 E 205050 5 P 205160 16 E 205170 17 P 205250 25 T M-4B 0.481 0.494 0.434 0.458 0.495 0.453, 0.469 0.209 0.483 0.494 0.436 0.448 0.444 0.491 0.454 0.247" 0.323 0.342 0.319 0.365 0.505 82-76 88-82 76-70 76-70 76-70 88-82 76-70">88 88-82>88 88-82>88>88**DRAWING NUMBER M-7B 208550 55 T 208600 60 P 208610 61 E 208620 62 P 208630 63 T 208640 64 P*'*DRAWING NUMBER M-10 211060 1F P 0.151 0.395 0.298 0.303 0.310 0.362 0.336 0.273>88>88>88>88>88>88 76-70**DRAW 212010 212020 212030 212040 212050 212060 212070 212080 212090 212100 212110 212120 212130 212150 212160 212180 212190 ING NU 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 18 19 MBER M-10A P E P E P P E P E P P P P E P P P 0.334 0.299 0.324 0.327 0.333 0.343 0.329 0.326 0;344 0.324 0.344 0.322 0.329 0.322 0.281 0.169 0.169>88>88 88-82 88-82>88>88 88-82 88-82>88 88-82>88 88-82 88-82 88-82 76-70<65<65 Table 1 l f 4 t, Page No.05/15/90  
COMP       TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO.                 READING   READING NOMINAL
** DRAWING     NUMBER   M-1 200010     1       P     0.602     0.595    88-82 200015     1A     P     0.534     0.669     >88
"* DRAWING     NUMBER M-4B 204510    51            0.481     0.483    82-76 204520    52      E      0.494    0.494      88-82 204570    57      E      0.434    0.436      76-70 204590    59      E      0.458    0.448      76-70 204600    60      P      0.495    0.444      76-70 204610    61      E      0. 453,  0.491      88-82 204630    63      R      0.469    0.454      76-70 204840'4          P      0.209    0.247"   ">88
** DRAWING      NUMBER 205040    4        E                0. 323     88-82 205050    5        P                0.342     >88 205160    16      E                0.319     88-82 205170    17      P                0.365     >88 205250    25      T                0.505     >88
** DRAWING     NUMBER M-7B 208550   55     T                 0.395      >88 208600   60     P                 0.298      >88 208610   61     E                 0.303      >88 208620     62     P                 0.310      >88 208630     63     T                 0.362      >88 208640     64     P                 0.336      >88
*'* DRAWING NUMBER M-10 211060 1F         P       0.151     0.273     76-70
** DRAWING    NUMBER  M-10A 212010    1      P                 0.334     >88 212020    2        E                0. 299   >88 212030    3        P                0.324     88-82 212040    4        E                0.327     88-82 212050    5        P                0.333     >88 212060    6        P                0.343     >88 212070    7        E                0.329     88-82 212080    8        P                0.326     88-82 212090    9        E                0;344     >88 212100    10      P                0.324     88-82 212110    11      P                0.344     >88 212120    12      P                0.322     88-82 212130    13      P                0.329     88-82 212150    15      E                0.322     88-82 212160    16      P                0.281     76-70 212180    18      P                0.169     <65 212190    19      P                0.169     <65 Table 1
 
l f
4   t,
 
Page No.
05/15/90


==SUMMARY==
==SUMMARY==
COMP TYPE 1989 MIN.NUMBER NO.READING 1990 MIN.READING PERCENT NOMINAL 212200 20 212210 21 212220'2 212230 23 212240 24**DRAWING NUMBER 213010 2A P 213020 2B P 213030 2C P 213040 2D P 213050 2E P 213060 2F P 213070 2G P M-10B 0.314 0.302 0.318'.281 0.289 0.329 0.322 0.291 0.308 0.317 0.176 0.318 88-82 82-76 88-82 76-70 82-76 88-82 88-82 82-76 88-'82 88-82<65 88-82**DRAWING NUMBER M-11A 215410 41 P 215411 41A E 215412 41B P 215420 42 E**DRAWING NUMBER M-11B~216100 88 T 0.363 216300 108 P 0.375 216440 122 T 0.315**DRAWING NUMBER M-12A 222280 26 P 0.361 0.456 0.358 0.424 0.388 0.470 0.371 0.358 0.361>88 88-82>88>88>88 88-82 88-82 88-82**DRAWING NUMBER 222490 47 R 222495 47B P 222500 48 E 222510 49 P 222890 87 E 222900 88 P 222905 88A R 222910 89 T**DRAWING NUMBER 223040 101 E 223050 102 P 223080 105 E 223090 106 P 223095 106A R M-12B 0.357 0.497 M-12A 0.372 0.316 0.302 0.394 0.429 0.386 0.332.0.343 0.456 , 0.584 0.446 0.400 0.346 0.304 0.421 88-82>88 82-76>88 82-76 82-76>88>88>88'88 82-76 76-70>88**DRAWING NUMBER M-15A 226250 25 E 0.259 226480 48 E 0.246 0.258 0.307 88-82>88 Table 1  
COMP     TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO.                 READING     READING NOMINAL 212200   20                           0.314   88-82 212210    21                          0.302   82-76 212220'2                              0. 318'.
~, I Page No.05/15/90  
88-82 212230    23                              281  76-70 212240    24                          0.289    82-76
** DRAWING    NUMBER  M-10B 213010    2A    P                    0. 329  88-82 213020    2B    P                    0.322    88-82 213030    2C    P                    0.291    82-76 213040    2D    P                    0.308    88-'82 213050    2E    P                    0.317    88-82 213060    2F    P                    0. 176  <65 213070    2G    P                    0. 318  88-82
** DRAWING   NUMBER M-11A 215410   41     P                     0. 456  >88 215411   41A   E                     0.358    88-82 215412   41B   P                     0. 424  >88 215420   42     E                     0.388    >88
** DRAWING   NUMBER M-11B   ~
216100   88     T       0.363         0. 470  >88 216300   108   P       0.375         0.371    88-82 216440   122   T       0.315         0.358    88-82
** DRAWING   NUMBER M-12A 222280   26     P       0.361         0.361   88-82
** DRAWING   NUMBER M-12B 222490   47     R                     0. 302  88-82 222495   47B   P                     0.394    >88 222500   48     E                     0.429    82-76 222510   49     P                     0.386    >88 222890   87     E                     0.332    82-76 222900   88     P       0.357    . 0.343    82-76 222905   88A   R                     0.456    >88 222910   89     T       0.497      , 0.584    >88
** DRAWING   NUMBER M-12A 223040   101   E       0.372         0.446   >88'88 223050    102    P                    0.400 223080    105    E                    0.346   82-76 223090    106    P      0.316        0.304    76-70 223095    106A  R                    0.421    >88
** DRAWING   NUMBER M-15A 226250   25     E       0.259         0.258    88-82 226480   48     E       0.246         0.307   >88 Table 1
 
  ~,
I
 
Page No.
05/15/90


==SUMMARY==
==SUMMARY==
COMP TYPE 1989'IN~NUMBER NO.READING 1990 MIN.READING PERCENT NOMINAL**DRAWING NUMBER M-15B 227440 96 E 0.253 227500 102 E 0.265 0.299 0.285>88 88-82 DRAWING NUMBER 228060 6 E 228270 27 E**DRAWING NUMBER 230410 41 E M-16 0.235 0.288 M-17A 0.271 0.260 0.287 0.316 88-82 88-82>88"*DRAWING NUMBER M-17B 231020 52 E 0.353 231410 91 P 0.255 231420 92 E 0.240 0.372 0.313 0.297 88-82>88>88**DRAWING NUMBER 232070 7 E 232080 8 P 232090 9 E 232100 10 P 232260 26 T 232330 33 E 232340 34 P 232350 35 E 232360 36 P 232520 52 T 232580 58 E 232590 59 P**DRAWING NUMBER 234405 40A E 234420 42 E 234455 45A R 234457 45B R 234465 46A R M-18 M-19 0.306 0.360 0.283 0.266 0.275 0.291 0.338 0.277 0.298 0.291 0.293 0.309 0.481 0.540 0.334 0.362 0.374 0.366 0.281>88 88-82 88-82>88>88 88-82>88>88>88 88-.82>88>88 82-76 88-82>88>88>88**DRAWING NUMBER M-27 253260 26 P 0.309 253270 27 E 0.302"*DRAWING NUMBER M-28 254250 25 E 0.312**DRAWING NUMBER M-31 260020 2 T 0.359 260241 24A E 260242 24B E 0.307 0.357 0.385 0.466 0.384 0.363 82-76>88>88>88>88 88-82 Table 1 e
COMP     TYPE   1989'IN ~ 1990 MIN. PERCENT NUMBER NO.                 READING     READING NOMINAL
Page No.05/15/90  
** DRAWING     NUMBER   M-15B 227440   96     E     0.253       0.299      >88 227500   102     E     0.265       0.285     88-82 DRAWING NUMBER     M-16 228060   6     E       0.235      0.260      88-82 228270   27     E       0.288      0.287      88-82
** DRAWING     NUMBER M-17A 230410   41     E       0.271       0.316     >88
"* DRAWING     NUMBER M-17B 231020     52     E       0.353       0.372      88-82 231410     91     P       0.255       0.313      >88 231420     92     E       0.240       0.297     >88
** DRAWING     NUMBER M-18 232070   7       E                   0.283      >88 232080     8     P                   0.266      88-82 232090   9       E                   0.275      88-82 232100     10     P                   0.291      >88 232260   26     T                   0.338      >88 232330   33     E                   0.277      88-82 232340   34     P                   0.298      >88 232350   35     E                   0.291      >88 232360   36     P                   0.293      >88 232520   52     T                   0.309      88-.82 232580   58     E                   0.481      >88 232590   59     P                   0.540      >88
** DRAWING     NUMBER M-19 234405   40A     E     0.306       0.334      82-76 234420    42      E      0.360        0.362     88-82 234455    45A    R                  0.374     >88 234457    45B    R                  0.366     >88 234465    46A    R                  0.281     >88
** DRAWING     NUMBER M-27 253260   26     P     0.309       0.307      82-76 253270   27     E     0.302       0.357      >88
"* DRAWING   NUMBER   M-28 254250   25     E     0.312       0.385      >88
** DRAWING   NUMBER   M-31 260020   2       T     0.359       0.466      >88 260241   24A     E                   0.384      >88 260242   24B     E                   0.363     88-82 Table 1
 
e Page No.
05/15/90


==SUMMARY==
==SUMMARY==
COMP TYPE 1989 MIN.NUMBER NO.READING 1990 MIN.READING PERCENT NOMINAL"*DRAWING NUMBER M-32 261380 38 E 261390 39 P 261400 40 E 261410 41 P 261420 42 E 261430 43 R 261460 46 E 261470 47 E 261500 50 P**DRAWING NUMBER M-92 281200 20 E 281310 31 E 0.351**DRAWING NUMBER M-41A 290016 1B R**DRAWING NUMBER M-41B 291020 41 E 291030 42 P**DRAWING NUMBER M-45 298520 52 P 0.332"*DRAWING NUMBER M-90 300440 43 P 0.297**DRAWING NUMBER M-91 300840'38 E 0.291**DRAWING NUMBER M-21 301025 2A D 0.362 301040 4 P 301050 5 E 301100 10 R 301180 17 E 301250 23 P 301260 24 E 301270 25 P 301280 26 E 301290 27 P 301300 28 E 301310 29 P'301320 30 T 0.496 301390 37 E 301400 37A P" 301405 39B P 301410 38 E 301420 39 P Table 1 0.396 0.388 0.392 0.390 0.412 0.320 0.533 0.612 0.547 0.450 0.351 0.447 0.417 0.407 0.319 0.298 0.297 0.351 0.703 0.809 0.759 0.759 0.400 0.267 0.151 0.324 0.233 0.258 0.275 0.473 0.309 0.342 0.333 0.312 0.354~,>88>88>88>88>88>88>88>88>88 76-70>88>88>88>88 76-70 70-65 70-65 76-70>88>88>88>88 82-76 76-70<65 88-82<65 70-65 76-70 76-70 88-82>88>88 88-82>88 W~\I'1  
COMP     TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO.                 READING   READING NOMINAL
'Page No.05/15/90  
  "* DRAWING NUMBER M-32 261380   38     E                 0.396    ~,>88 261390   39     P                 0.388      >88 261400   40     E                 0.392      >88 261410   41     P                 0.390      >88 261420   42     E                 0.412      >88 261430   43     R                 0.320      >88 261460   46     E                 0.533      >88 261470   47     E                 0.612      >88 261500   50     P                 0.547      >88
  ** DRAWING     NUMBER M-92 281200   20     E                 0.450      76-70 281310   31     E       0.351     0.351      >88
  ** DRAWING     NUMBER M-41A 290016   1B     R                 0.447      >88
  ** DRAWING     NUMBER M-41B 291020   41     E                 0.417      >88 291030   42     P                 0.407      >88
  ** DRAWING     NUMBER M-45 298520   52     P       0.332     0.319      76-70
  "* DRAWING NUMBER     M-90 300440   43     P       0.297     0.298      70-65
  ** DRAWING     NUMBER M-91 300840 '38       E       0.291     0.297      70-65
  ** DRAWING   NUMBER   M-21 301025   2A     D       0.362     0.351      76-70 301040   4       P                 0.703      >88 301050   5       E                 0.809      >88 301100   10     R                 0.759      >88 301180   17     E                 0.759      >88 301250   23     P                 0.400      82-76 301260   24     E                 0.267      76-70 301270   25     P                 0. 151    <65 301280   26     E                 0.324      88-82 301290   27     P                 0.233      <65 301300   28     E                 0.258      70-65 301310   29     P                 0.275      76-70
  '301320   30     T       0.496     0.473      76-70 301390   37     E                 0.309      88-82 301400   37A     P                 0.342      >88 301405   39B     P                 0.333      >88 301410   38     E                 0.312      88-82 301420   39     P                 0.354     >88 Table 1
 
W
~\
I' 1
 
'Page No.
05/15/90


==SUMMARY==
==SUMMARY==
COMP NUMBER NO.TYPE 1989 MIN.READING 1990 MIN.READING PERCENT NOMINAL 301425 39A 301430 40 301450 42 301470 44 E E P E 0.338 0.356 0.361 0.374>88>88>88>88 301705 1B 301780 9 301830 14 302010 28 302020 29 302030 30 302090 35 302110 37 302120 37A 302130 38 302140 39 302150 40 D E R P P E E T P E P E**DRAWING NUMBER M-22 0.342 0.669 0.332 0.502 0.400 0.676 0.733 0.320 0.155 0.328 0.311 0.498 0.300 0.185 0.324 0.298 82-76 76-70 88-82<65<65 88-82 88-82 76-70 82-76<65 88-82 82-76**DRAWING NUMBER M-75 303010 1 303015 1A 303017 1B 303020 2 303160 16 303165 16A 303167 16B 303220 22 303230 23 303235 23A 303240 24 P R N T P R N P-T P E 0.343 0.271 0.318 0.211 0.318 0.110 0.200 0.318 0.353 0.161 0.250 0.366 0.463 0.344 0.372 88-82<65<65 88-82>88<65<65>88>88>88>88 304420 304425 304430 304435 304440 304450 304460 304560 304950 304955 304960 304970 304980 304990 305000 305010 305020 2 2A 3 3A 4 5 6 16 55 55A 56 57 58 59 60 61 62 E P V P E P V E E P E P E V P V P**DRAWING NUMBER M>>88A 0.160 0.170 0.160 0.160 0.150 0.160 0.150 0.170 0.170 0.160 0.150 0.140 0.180 0.250 0.283 0.160 0.160 0.280 0.160 0.300 0.250 0.220 76-70 70-65 NE<65 88>>82>88 NE>88 76-70 76-70>88 76-70>88 NE>88 NE>88 Table 1 k*\,-1\el.P-1~I 4 Page No.05/15/90  
COMP     TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO.                READING  READING NOMINAL 301425   39A   E                 0.338     >88 301430    40    E                0. 356   >88 301450    42    P                0.361     >88 301470    44    E                0.374     >88
** DRAWING     NUMBER   M-22 301705  1B      D      0.342   0.400      82-76 301780  9      E      0.669    0.676     76-70 301830  14      R                0.733     88-82 302010  28      P                0.320     <65 302020  29      P                0.155     <65 302030  30      E                0.328     88-82 302090  35      E      0.332    0.311      88-82 302110  37      T      0.502    0.498      76-70 302120  37A    P                0.300      82-76 302130  38      E                0.185    <65 302140  39      P                0.324    88-82 302150  40      E                0.298    82-76
** DRAWING     NUMBER M-75 303010   1       P                0.318    88-82 303015   1A     R                0. 110    <65 303017   1B     N                0.200    <65 303020   2       T     0.343     0.318    88-82 303160    16      P                0.353    >88 303165    16A    R                0.161    <65 303167    16B    N                0.250    <65 303220    22      P-    0.271    0.366    >88 303230    23      T      0.318     0.463    >88 303235    23A    P                0.344    >88 303240    24    E      0.211    0.372     >88
** DRAWING   NUMBER M>>88A 304420  2      E      0.160     0. 160   76-70 304425  2A      P      0.170    0. 150   70-65 304430  3      V                          NE 304435  3A      P      0. 160   0. 140    <65 304440  4      E      0.160     0. 180   88>>82 304450  5      P                0. 250   >88 304460  6      V                          NE 304560  16      E                0.283     >88 304950  55      E      0. 150    0.160     76-70 304955  55A    P      0.160    0.160     76-70 304960  56      E                0.280    >88 304970  57      P      0.150    0.160    76-70 304980  58      E                0.300    >88 304990  59      V                          NE 305000  60      P      0. 170    0.250    >88 305010  61      V                          NE 305020  62      P      0.170    0.220    >88 Table 1
 
k*
      \,
  -1
\
el.
P 1
~I 4
 
Page No.
05/15/90


==SUMMARY==
==SUMMARY==
COMP TYPE 1989 MIN.NUMBER NO.READING 1990 MIN.READING PERCENT NOMINAL 305090 69 E**DRAWING NUMBER M-48 320370 37 E 320390 39 P 320400 40 E**DRAWING NUMBER M-49 323420 42 P 0.266 0.261 0.265 0.287 0.285 0.269 88-82>88>88>88>88**DRAWING NUMBER 327070 7 E 327080 8" P 327180 18 T 327190 19 P 327200 20 E 327250 25 E 327500 50 E 327510 51 P 327570 57 E**DRAWING NUMBER 328115 11A R 328125 12A R 328130 13 P M-47 0.296 M-46B 0.321 0.352 0.330 0.278.0.287 0.314 0.288 0.292 0.348 0.311 0.352 0.420 88-82>88>88'88>88 88-82>88>88>88>88>88>88**DRAWING NUMBER M-46A 329230 53 E 0.362 0.352 82-76*" DRAWING NUMBER 385010 1 E 385080 8 P 385100 10 P 385260 26 E 385290 29 P 385420 42 E 385470 47 P'85490 49 P 385660 66 E 385680 68 P 385800 80 L M-88D 0.280 0.262 0.288 0.275 0.286 0.289 0.273 0.255 0.271 0.272 0.308>88 88-82>88>88>88>88>88 88-82>88>88<65**DRAWING NUMBER M-81 390060 6 R 0.653 0.614 76-70**DRAWING NUMBER 395010 1 P 395030 3.P 395040 4" E 395100 10 E M-94 0.267 0;242 0.277 0.301 0.270 0.277>88>88>88>88 Table 1 4f Page No.05/15/90  
COMP         TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO.                       READING   READING NOMINAL 305090     69       E                     0.261    88-82
** DRAWING     NUMBER         M-48 320370     37       E                     0. 265  >88 320390     39       P                     0.287    >88 320400     40       E                     0.285    >88
** DRAWING     NUMBER         M-49 323420   42         P           0.266     0.269   >88
** DRAWING     NUMBER         M-47 327070   7         E           0.296      0.321    88-82 327080   8         P                     0.352    >88 327180   18         T                     0.330    >88'88 327190   19         P                     0.278 327200   20         E                   . 0.287    >88 327250   25         E                     0. 314  88-82 327500   50         E                     0.288    >88 327510   51         P                     0. 292  >88 327570   57         E                     0.348    >88
** DRAWING     NUMBER         M-46B 328115   11A       R                     0. 311  >88 328125   12A       R                     0.352    >88 328130   13         P                     0.420   >88
** DRAWING     NUMBER         M-46A 329230   53         E         0.362       0.352   82-76
*" DRAWING NUMBER M-88D 385010   1         E                     0.280    >88 385080   8         P                     0.262    88-82 385100   10         P                     0.288    >88 385260   26         E                     0.275    >88 385290   29         P                     0.286    >88 385420   42         E                     0.289    >88 385470   47         P                     0.273   >88 49        P '85490 0.255   88-82 385660 66            E                      0.271   >88 385680 68            P                      0.272   >88 385800    80        L                      0.308   <65
** DRAWING   NUMBER           M-81 390060   6         R         0.653       0. 614   76-70
** DRAWING   NUMBER           M-94 395010   1         P                     0.277    >88 395030   3     . P                     0.301    >88 395040   4   "
E         0.267      0.270    >88 395100   10         E         0;242       0.277   >88 Table     1
 
4f Page No.
05/15/90


==SUMMARY==
==SUMMARY==
NUMBER COMP NO.TYPE 1989 MIN.READING 1990 MIN.READING'ERCENT NOMINAL 395180 395190.395210 395230 395240 395270 395290'95360 395400 395440 395450 395470 395490 395500 18 19 2r.23 24 27 29 36 40 44 45 47 49 50 E P P'E P P E 0.231 E E P P P E 0.290 0.280 0.306 0.298 0.293 0.305 0.288 0.262 0.281 0.259 0.280 0.302 0.'300 0.309>88>88>88>88 88-82.>88>88 88-82>88 88-82>88>88>88>88**DRAWING NUMBER NA 400001 400002 400003 400004 400005 400006 400007 400008 400009 400010 400011 400012 400013 400014 400015 400016 400017 400018 400019 400020 400021 400023 400024 400025 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA E E R R P E E'P L E E P T P P P E P E P T P P E 0.759 0.672 0.381 0.359 0.397 0.427 0.277 0.265 0.234 0.252 0.240 0.160 0.200 0.102 0.200 0.195 0.190 0.200 0.230 0.195 0.250 0.180 0.180 0.230>88>88>88>88>88>88>88>88>88>88>88>88>88<65>88>88>88>88>88>88>88>88>88>88**DRAWING NUMBER M-89A 400026 400027 400028 400029 400030 40003'1 400032 400033 14 15 16 17 18 19 20 28 N P T P T P P P 0.500 0.'225 0.270 0.218 0.350 0.210 0.179 0.210>88>88>88>88>88>88.>88>88 Table 1  
COMP           TYPE 1989 MIN. 1990 MIN.'ERCENT NUMBER NO.                    READING  READING NOMINAL 395180         18     E               0. 290    >88 395190        19    P               0.280    >88
.395210        2r. P'              0.306     >88 395230        23                      0.298     >88 395240        24    E                0.293     88-82 .
395270        27    P                0.305     >88 395290        29    P                0.288     >88
        '95360 36    E      0.231    0.262     88-82 395400        40    E                0.281     >88 395440        44      E                0.259     88-82 395450        45      P                0.280     >88 395470        47      P                0.302     >88 395490        49      P                0.'300   >88 395500        50      E                0.309     >88
** DRAWING         NUMBER NA 400001       NA     E               0. 759   >88 400002        NA      E                0.672     >88 400003        NA      R                0.381     >88 400004        NA      R                0.359     >88 400005        NA      P                0.397     >88 400006        NA      E                0.427     >88 400007        NA      E                0.277     >88 400008        NA    'P                0.265     >88 400009        NA      L                0.234     >88 400010        NA      E                0.252     >88 400011        NA      E                0.240     >88 400012        NA      P                0.160     >88 400013        NA      T                0.200     >88 400014        NA      P                0.102     <65 400015        NA      P                0.200     >88 400016        NA      P                0.195     >88 400017        NA      E                0.190     >88 400018        NA      P                0.200     >88 400019        NA      E                0.230     >88 400020        NA      P                0.195     >88 400021        NA      T                0.250     >88 400023        NA      P                0.180     >88 400024        NA      P                0.180     >88 400025        NA      E                0.230     >88
** DRAWING         NUMBER   M-89A 400026         14     N                 0. 500   >88 400027        15    P                0.'225   >88 400028        16    T                0.270     >88 400029        17    P                0.218     >88 400030        18    T                0.350     >88 40003'1        19    P                0.210     >88 .
400032        20    P                0.179     >88 400033        28    P                0.210     >88 Table 1


Page No.05/15/90  
Page No.
05/15/90


==SUMMARY==
==SUMMARY==
COMP NUMBER NO.TYPE 1989 MIN.READING 1990 MIN.READING PERCENT NOMINAL 400034 29 400035 30**DRAWING NUMBER M-89B 0.270 0.210>88>88 400036 8A 400037 9 400038 11 400039 12 400040 24 P T P P P 0.190 0.300 0.220 0.190 0.170 88-82>88>88 88-82>88**DRAWING NUMBER M-89C 400041=26 400042 27 400043 28 400044 29 400045 30 400046 31 T P E P T P 0.300 0.180 0.300 0.190 0.290 0.170>88 88-82>88 88-82>88 82-76*" DRAWING 400047 1 400048 2 400049 3 400050 4'00051 5 400052 6 400053 7 400054 8 400055 D 400056 C 400057 B 400058 A NUMBER NA P P P P P P P P P 0.281 0.261 0.280 0.274 0.259 0.267 0.250-0.253 0.274 0.234 0.247 0.230 76-70 76-70 76-70 76-70 70-65 76-70 70-65 70-65 76-70 (65 70-65<65**DRAWI 400059 400060 400061 400062 400063 400064 400065 400066 400067 400068 400069 400070.400071 400072 400073 400074'00075 NG NUMB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ER E E E E P P P P E E E E P P P P P M-SW 0.360 0.361 0.350 0.359 0.337 0.342 0.332 0.321 0.346 0.341 0.365 0.355 0.312 0.331 0.353 0.346 0.322>88>88>88>88>88>88>88 88-82>88>88>88>88 88-82>88.>88>88 88-82 Table 1 I
COMP             TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO.                        READING    READING NOMINAL 400034       29                           0.270      >88 400035       30                           0.210    >88
Page No.05/15/90  
** DRAWING             NUMBER M-89B 400036      8A          P                0. 190    88-82 400037      9            T                0.300    >88 400038       11           P               0.220     >88 400039      12          P                0.190     88-82 400040      24            P                0.170     >88
** DRAWING             NUMBER M-89C 400041=     26           T               0.300     >88 400042      27            P                0.180     88-82 400043      28            E                0.300     >88 400044      29            P                0.190     88-82 400045      30            T                0.290     >88 400046      31            P                0.170     82-76
*" DRAWING           NUMBER NA 400047     1           P                 0.281     76-70 400048      2            P                0.261     76-70 400049      3            P                0.280     76-70 400050      4            P                0.274     76-70 5  '00051 P                0.259     70-65 400052      6            P                0.267     76-70 400053      7            P                0.250     70-65 400054      8            P                -0.253     70-65 400055      D            P                0.274     76-70 400056      C                              0.234     (65 400057      B                              0.247     70-65 400058      A                              0.230     <65
** DRAWING          NUMBER M-SW 400059       1           E                 0.360     >88 400060      2            E                0.361     >88 400061      3            E                0.350     >88 400062      4            E                0. 359   >88 400063      5            P                0.337     >88 400064      6            P                0. 342   >88 400065      7            P                0. 332   >88 400066      8            P                0. 321   88-82 400067      9            E                0.346     >88 400068      10          E                0.341     >88 400069      11          E                0.365     >88 400070.      12          E                0.355     >88 400071      13          P                0.312     88-82 400072      14          P                0.331     >88.
400073      15          P                0.353     >88 400074'00075 16          P                0.346     >88 17          P                0.322     88-82 Table 1
 
I Page No.
05/15/90


==SUMMARY==
==SUMMARY==
COMP TYPE 1989 MIN.1990 MIN.PERCENT NUMBER NO.READING READING NOMINAL 400076 400077 400078 400079 400080 400081 400082 400083 400084 400085 18 T 19 P 20 T 21 P 22 P 23 P 24 T 25 P 26 T 27 P 0.468 0.325 0.425 0.331 0.327 0.335 0.458 0.330 0.425 0.337>88 88-82>88>88 88-82>88>88 88-82>88>88 Abbreviation D=E=P-R=T=Component Type Downcomer Nozzle Pipe Reducer Tee Table l kgb I l GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990-1999 Interval, First Outage 1990 Attachment III Miscellaneous NDE Examination Summary Report This section consist of all examinations performed as a"service" by Materials Engineering and Inspection Services.The documented results of the below listed examinations have been submitted to the requesting individual and/or department for proper processing.
COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO.             READING READING NOMINAL 400076     18 T               0.468    >88 400077    19 P               0.325    88-82 400078    20 T               0.425    >88 400079    21 P               0.331    >88 400080    22 P               0.327    88-82 400081    23 P               0.335    >88 400082    24 T               0.458    >88 400083    25 P               0.330    88-82 400084    26 T               0.425    >88 400085    27 P               0.337    >88 Abbreviation  Component Type D=            Downcomer E=            Nozzle P-            Pipe R=            Reducer T=            Tee Table  l
The results of all examinations listed below in this"Mis'cellaneous" Section are acceptable unless otherwise specified.
 
The following examinations were performed under the Maintenance Inservice Inspection Program (MISIP).A.Visual Examinations:
kgb I
1.Reactor Coolant Pump Motor Lift Sling.2.Reactor Vessel Head Lift Rig.3.Reactor Vessel Internals Lift Rig.4.Steam Generator"A" 8c"B"-Tubelane Blocking Device Tack Welds.B~Ma netic Particle Examinations:
l
1.Containment Crane Hooks-7 Hooks Total.2.Reactor Head Chain Hoist Hooks-3 Hooks Total.3.Forklift Forks-11 Forklift Trucks Total.4.Pallet Cart Forks-11 Pallet Carts Total.5.Steam Generators"A" 4,"B"-Secondary Manway Covers.6.Steam Generator"B"-&#xb9;4 and&#xb9;6 Wedge Port Covers.C.Visual and Liciuid Penetrant Examinations:
 
1.Steam Generator Nozzle Dams-10 Dams Total.D.Ultrasonic Examinations:
GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990  1999  Interval, First    Outage 1990 Attachment  III Miscellaneous  NDE  Examination Summary Report This section consist of all examinations performed as a "service" by Materials Engineering and Inspection Services.          The documented results of the below listed examinations have been submitted to the requesting individual and/or department for proper processing.           The results of all examinations listed below in this "Mis'cellaneous" Section are acceptable unless otherwise specified.
1.Steam Generator"B"-&#xb9;4 and&#xb9;6 Wedge Port Bolts.E.Visual and~Ma netic Particle Examinations:
The   following examinations were performed under the Maintenance Inservice Inspection Program (MISIP).
1.Steam Generators"A" and"B"-Handhole Covers-North and South.
A. Visual Examinations:
t f P.Visual~Ma netic Particle and Ultrasonic Examinations:
: 1. Reactor Coolant Pump Motor Lift Sling.
1.Steam Generators"A" and"B"-Secondary Manway Bolts.2.Steam Generators"A" and"B"-Handhole Cover Bolts North and South.3.Steam Generator"A"-Outlet Nuts and Studs.4.Steam Generator"B"-Inlet Nuts and Studs.5.Steam Generator"B"-Outlet Nuts and Studs.~urb'ne Com o ants: The following examinations were performed on Turbine Components.
: 2. Reactor Vessel Head Lift Rig.
Note: Respectable Examination results are reported to the Turbine Department for disposition and corrective action as required.A.Visual Examinations:
: 3. Reactor Vessel Internals Lift Rig.
1.Inner Cylinder (&#xb9;2)-Stationary Blade Rings Governor End, Stages 8, 9, 10 and 11.B.Liciuid Penetrant Examinations:
: 4. Steam Generator "A" 8c "B"- Tubelane Blocking Device Tack Welds.
1.L.P.Turbine-&#xb9;3 Bearing'abbitt Surface.2.Valve Stem Seat-Main Steam Stop Valve..3.Stellite Seats-&#xb9;2 and&#xb9;4 Control Valves.4.Outer Diaphragm-Top Outside Welds.II,/Indication.
B   ~Ma netic Particle Examinations:
5.Outer Diaphragm-Bottom Inside Welds.Re'ectable-Inside Welds;Vertical Weld&#xb9;3, 4 1/2" Linear Thru Wall Indication; Welds&#xb9;7&, 8, 22 Cold Lap Indications.
: 1. Containment Crane Hooks       7 Hooks Total.
6~Inner Diaphragm-Top Outside Welds.7.Inner Diaphragm-Bottom Inside Welds.8."C" L.P.Rotor-Stellite Ends.Re'ectable-Blade W7G at Governor End Stage 9 contained Linear Indication 1/4" Long at Blade Edge.9."1" LE P.Rotor-Outer Diaphragms
: 2. Reactor Head Chain Hoist Hooks 3 Hooks Total.
-crossover Pipe.C.~Ma netic Particle Examinations:
: 3. Forklift Forks - 11 Forklift Trucks Total.
1.L.P.Turbine Inner Cylinder-Blade Rings&, Flow Dividers, I 21 Linear Indications at Inner Edge of Blades;Upper Blade Ring 4th Stage Contained 9 Linear Indications on Inner Edge of Blades;Lower Blade Ring 2nd Stage Contained 4 Linear Indications on Inner Edge of Blades;Upper Blade Ring 2nd Stage contained 9 Linear Indications on Inner Edge of Blade;3rd Stage Contained 2 Linear Indications on Inner Edge of Blade and Between the 3rd and 4th Stages had 1 Linear Indication on Base Surface;Lower Blade Ring 4th Stage Contained 45 Linear Indications on Inner Edge of Blades.
: 4. Pallet Cart Forks "A"11 Pallet     Carts Total.
C~'K tl l A l 2~3.4.5.6.7~8.&#xb9;2 Inner Cylinder-Governor End Stages.Weld-Steam Undercut on Base Side.a Upper Inner Cylinder-Steam Seals, Control Valve Muffler and Baskets.II Indications on Inner Edge, of Blades;&#xb9;1 Upper Inner Cylinder (other side)Contained 12 Indications on Inner Edge of Blades.Inner, Crossover Diaphragm.
: 5. Steam Generators       4, "B" Secondary   Manway Covers.
Outer Crossover Diaphragm."C" L.P.Rotor-End Shafts."C" L.P.Rotor-Generator End-Stages 1-11."C" L.P.Rotor-Generator End-Stages 1-11.D.Ultra 1~2~3~4e 5.6.7~8.9.10.11'2'3'4.15.16.17'8.19.20.21'2'3'4~sonic Examinations:
: 6. Steam Generator "B" &#xb9;4 and &#xb9;6 Wedge Port Covers.
&#xb9;5 Bearing-Top&, Bottom Halves-Babbitt, Bonding.Inner 8L Outer Shell Dowel Studs-14 Studs Total.Inner&, Outer Shell Studs-92 Studs Total.Control Valve Studs-52 Studs Total.Stop Valve Studs-30 Studs Total.Crossover Hi Hat Studs-52 Studs Total.Inner Cylinder Shell Studs-55 Studs Total.H.P.'oupling Studs-20 Studs Total.Stop Valve Pilot&, Mummy Studs-24 Studs Total.Outer Cylinder Shell Studs-52 Studs Total.Jack Shaft Thrust Studs-30 Studs Total.Cross Pipe Vertical Joint-44 Studs Total.Crossover Pipe Diaphragm-52 Bolts Total.Crossover Studs-5 Studs Total.Inner Cylinder-17 Studs Total.Control Valve Tension Bolts-2 Bolts Total.Blade Ring-4 Studs Total.Stud 688J343-19
C. Visual and Liciuid Penetrant Examinations:
-25 Studs Total.Inner Shell Studs-682J249-23
: 1. Steam Generator Nozzle Dams       10 Dams Total.
-2 Studs Total.Inner Shell Studs-682J343-21
D. Ultrasonic Examinations:
-4 Studs Total.Inner Shell Studs-682J343-16
: 1. Steam Generator   "B" - &#xb9;4 and &#xb9;6 Wedge   Port Bolts.
-4 Studs Total.Upper Studs-885J343-19
E. Visual and   ~Ma netic Particle "A"
-25 Studs Total.Inner Shell Studs-'82J342-15
Examinations:
-12 Studs Total.Miscellaneous Turbine Studs-120 Studs Total.E.Liciuid Penetrant and Ultrasonic Examinations:
                                        "B"
1.Upper Babbitt, 2.Lower Babbitt.
: 1. Steam Generators       and       Handhole Covers   North and South.
II~  
 
~Wor$4eceests~WR~P The following examinations were performed in support of Engineering Work Requests (EWR's).A.Visual Examinations:
t f
1.1/2" Valves 1032-1&, 1032-2, Cleanliness-EWR 4613.the Joint"Prep" Joint, g3.Burr removed and verified by'luor Daniel QC personnel-Accepted.2.20" Service Water Header, Cleanliness-EWR 4930.B.Radio ra hic Examinations:
 
1.Containment Penetration
P. Visual     ~Ma netic Particle   and Ultrasonic Examinations:
-2 Welds-EWR 4998'and Linear Indications.
: 1. Steam Generators "A" and "B" Secondary Manway Bolts.
Repaired, Re-examined and Accepted.C.Visual and Ultrasonic Examinations:
: 2. Steam Generators "A" and "B" Handhole Cover Bolts North and South.
1.Heater Drain Tank Pump Barrels-"A" 8L"B"-EWR 5053.The following examinations were performed in support of Maintenance Work Orders (MWO's).A.Visual Examinations:
: 3. Steam Generator "A" - Outlet Nuts and Studs.
1.CV Equipment Hatch-Geneva Latch-Plug Welds.2.CV Floor Grating-Tack Welds.3.Pressurizer Safety Line-Nuts for Valves 434&, 435 Replacements (48 nuts&.93 studs accepted).
: 4. Steam Generator "B" Inlet Nuts and Studs.
Q Contained Axial Cracks in Hex Head, 2 Nuts Contained Thread Damage that Prevented Engagement on Stud.B.Ultrasonic Thickness Examinations:
: 5. Steam Generator "B" Outlet Nuts and Studs.
1.H.P.Turbine Drain Lines-Pipe&, Fittings-Wall Thickness.
    ~urb'ne   Com o   ants:
C.Visual and L'iciuid Penetrant Examinations:
The   following examinations were performed on Turbine Components.
1.3/4" Nitrogen Supply to AOV-846, 8 Socket Welds.2.Charging Pump"A"-3/4" Valve 281C&, Piping-8 Welds.3.Safety Injection Pump"B"-3/4" Nipple to Elbow Weld.4.MSIV 3516-Lug&Nut Locking Weld.
Note: Respectable Examination results are reported to the Turbine Department for disposition and corrective action as required.
1.e a',q 5.MS Non-return Check Valve 3518B-Disc Stop Welds.Re-Examined after Repairs-Acceptable.
A. Visual Examinations:
6.MS Non-return Check Valve 3519A-Disc Stop Welds.Re-Examined after Repairs-Acceptable.
: 1. Inner Cylinder (&#xb9;2) - Stationary Blade Rings Governor End, Stages   8, 9, 10 and 11.
7."A"&,"B" Service Water Pressure Gage-Header-Pipe Coupling Welds.(1" pipe to coupling to 20" pipe)8~Charging Pump"A",-Valve 285 to Pipe Weld.9.Charging Pump"B",-Valve 284 to Pipe Weld.10.Charging Pump"C",-Valve 283 to Pipe Weld./"/Weld Centerline.
B. Liciuid Penetrant Examinations:
Reexamined after repairs-, accepted.D.Liciuid Penetrant and~Ma netic Particle Examinations:
: 1. L.P. Turbine &#xb9;3 Bearing'abbitt Surface.
1~"A" Preseparator
: 2. Valve Stem Seat Main Steam Stop Valve..
-16" Diameter Pipe Replacement-3 Welds.k.~e The following examinations were performed in support of miscellaneous work.A.Visual Examinations on Welds: 1, Astregal Plate Welds-Fire Door&#xb9;23.2.Skin Repair-Fire Door&#xb9;F-500.3.Heater Drain Tank at Valve 3098, 1/2" Socket Welds 3 Welds.4.Freeze Plugs in Nitrogen Supply Lines.5."B" Reactor Coolant Pump-Insulation Support Welds.6, Steam Generator Blowdown-Socket Welds.7.DI System-Valve 8419-Valve Cap.8.Steam Generator Blowdown-Valve 5701, 2 Welds.9."B" Steam Extraction Line-5 Welds.10.Check Valve 4023-Tack Welds.11.Personnel Hatch-Outer Door-Geneva Latch Plate Plug Weld.12.Steam Generator Blowdown-Valve 5735-8 Socket Welds.13.Equipment Hatch Rollup Door-Channel to Plate, Angle and Lug~14."B" CCW Pump Motor Stand to Base Plate.B.Visual Examinations on Com onents: 1.Class 2 Valve Upgrade for Henze-Valve Nuts.2.Valve Stem-Feedwater Valve 4269.3.Steam Generator Primary Manway Washers-201 Washers Accepted.Re'ectable-2 Washers Contained Machine Cuts on ID Surface.
: 3. Stellite Seats &#xb9;2 and &#xb9;4 Control Valves.
s t4r.Ci P'1 yr 4, 5.6.7~8.9~10'ain Steam Support S-4, Re-exam for NCRG89-365.
: 4. Outer Diaphragm Top Outside Welds.
Service Water Headers-Screen House-Min Wall&Surface Condition.
II,     /
Service Water 20" Header-Pipe Downstream of Support SWU-616.Fire Doors&#xb9;37,&#xb9;46,&#xb9;27,&#xb9;26,&#xb9;79,&#xb9;61 and&#xb9;62-Fillet Welds.Service Water Screen House-Surface Condition Downstream from Valve 4606'./"/Wall Thickness Resulted in Identifying Wall to be 0.355" Thick.Remaining Wall Thickness is 0.305".Wall Loss at This Area 14X.Service Water Screen House-Surface Condition Downstream from Support SW-620.Re ectable-Random Pitting and Undercut Around Entire Circumference.
Indication.          Bottom Inside Welds.
Pitting 8 to 17X of Wall Thickness (1/64" to 1/16" Deep)."A" Service Water Pump-2 Rigid Restraints.
: 5. Outer Diaphragm Re 'ectable -Inside Welds; Vertical Weld &#xb9;3,         4   1/2" Linear Thru Wall     Indication;   Welds &#xb9; 7 &, 8, 22 Cold Lap Indications.
C.Liciuid Penetrant Examinations on Com onents: 1.Ten Inch (10")SI Line, 2" Weld-0-Let to Pipe.'"/90-102 Generated.
6 ~ Inner Diaphragm       Top Outside Welds.
Defects were Repaired by Blending, Re-.examined-Acceptable.
: 7. Inner Diaphragm Bottom Inside Welds.
2.Freeze Plugs for Leakage Examination on Pipe-2 Areas.3.Main Feedwater Pump-Shaft&, Impeller.4.Feedwater Valve 4272-Seat Examination.
: 8. "C" L.P. Rotor Stellite Ends.
5.Low Pressure Steam Extraction
Re 'ectable Blade W7G at Governor End Stage         9 contained Linear Indication 1/4" Long at Blade Edge.
-Bellows Welds.6,.Valve 4270-Stem, Seats, Plug&, Gage.7.Valve&#xb9;390-Filter Vent Socket Weld.8.CVCS-Pipe to Valve&#xb9;390.9.Hanging Scaffolds, Al, A2, Bl, B2&B3, 25 Welds Total.Re'ectable-Linear Indications in Bl&" B2.These welds are to be repaired and reexamined before the 1991 AI&0, 10.Bolts from Check Valves 870A, 870B, 889A&889B.D.~Ma netic Particle Examinations on Com onents: 1~Auxiliary Feedwater Valve 4017-Seat Area.NCR 90-96 was Generated.
: 9. "1"   LE P. Rotor   Outer Diaphragms     crossover Pipe.
Defects were Repaired and Re-examined-Acceptable.
C. ~Ma netic Particle Examinations:
2.L.P.Steam Extraction to 2A Heater Bellows.3.Steam Extraction Pipe to Elbow Welds.4.Steam Extraction to 5A&, 5B Heaters-Reducer Welds (2).5.Blowdown to Blown Tank-Component 80 Pad Weld.E.Ultrasonic Examinations on Com onents: l.Auxiliary Feedwater-Three Supports-Verify Bolt Lengths.2.1A&.1B Diesel Generators-Ductwork-Verify Bolt Lengths.3.Spent Fuel Pit"A"-Verify Bolt Lengths'.Support AFW-600, Verify Bolt Lengths.
: 1. L.P. Turbine       Inner Cylinder-Blade Rings &, Flow Dividers, I
I~4g-S A Pl t4 rr t jg I 5.Support SWU-623, Verify Bolt Lengths.6, Service Water-14" Diameter Pipe-Wall Thickness.
21 Linear Indications at Inner Edge of Blades; Upper Blade Ring 4th Stage Contained 9 Linear Indications on Inner Edge of Blades; Lower Blade Ring 2nd Stage Contained 4 Linear Indications on Inner Edge of Blades; Upper Blade Ring 2nd Stage contained 9 Linear Indications on Inner Edge of Blade; 3rd Stage Contained 2 Linear Indications on Inner Edge of Blade and Between the 3rd and 4th Stages had 1 Linear Indication on Base Surface;         Lower Blade Ring 4th Stage Contained 45 Linear Indications on Inner Edge of Blades.
7.Support SWU-625, Verify Bolt Lengths.8.S/G"A", Swirl Vane Wrapper-Wrapper Thickness.
 
Generated.
C~
Fabricated and Installed 7 Impingement Plates on Severely Eroded Areas.Use-As-Is on Feedwater Tee Erosion.A Monitoring Program Initiated for the Feedwater Tee 8c Steam Generator Wrapper Erosion not Repaired in.the 7 Areas Above.9.S/G"B", Swirl Vane Wrapper-Wrapper Thickness.
'K tl l
Re'ectable-Wrapper Thickness Eroding, NCR 90-124 Generated, Action Taken was Incorporated into Item 48 Above.10.Sampling Line at AOV 5736-Wall Thickness.
A l
11.Service Water Support SWU-631, SWU-632, SWU-633 and SWU-634, Verify Bolt Lengths.12.Service Water Support SWU-568, Verify Bolt Lengths.F.Visual and Liciuid Penetrant Examinations on Com onent.s: 1.RHR System-By Valve 687B-Sock-o-let Weld.2.Service Water Header-Valve 4799-2 Welds, Coupling, and"Prep" Areas.G.Visual and~Ma netic Particle Examinations on Com onents: l."A" S/G-Swirl Vane Wrapper Patches.Generated, Action Taken was Incorporated into Items 48&9 in Paragraph E Above.2.Main Steam System-Valve 3411-Flange Seal Area.H.Visual~Ma netic Particle F.Ultrasonic Examinat.iona on Com onents: 1.Retaining Block Studs-Baseline for Valves 870A, 870B, 880A and 880B.~1.Pipes and Elbows in the Min-Wall (Wall Thickness)
 
Program.2."B" Reactor Coolant Pump Insulation Support Bushings.1.Service Water-Elbow Downstream of Valve 9633B.2.Standby Auxiliary Feedwater-Pipe by Support SWO-508 0.207" Thickness, 1" 1.3/4," Chemical Feed Line to"A" S/G Feedwater.
2     ~ &#xb9;2 Inner Cylinder   Governor End Stages.
Angle Iron.Missing Nut on U-Bolt.
Weld-Steam Undercut on Base Side.
b/fan}}
a
: 3. Upper Inner       Cylinder   Steam Seals, Control Valve Muffler and Baskets.
II Indications on Inner Edge, of Blades; &#xb9;1 Upper Inner Cylinder (other side) Contained 12 Indications on Inner Edge of Blades.
: 4. Inner, Crossover Diaphragm.
: 5. Outer Crossover Diaphragm.
: 6. "C" L.P. Rotor - End Shafts.
7    ~
                "C" L.P. Rotor Generator End   - Stages 1 11.
: 8. "C" L.P. Rotor Generator End         Stages 1 11.
D. Ultra sonic Examinations:
1   ~   &#xb9;5 Bearing  Top &, Bottom Halves  Babbitt, Bonding.
~   Inner 8L Outer Shell Dowel Studs  14 Studs Total.
3   ~    Inner &, Outer Shell Studs  92 Studs Total.
4e        Control Valve Studs  52 Studs Total.
: 5.       Stop Valve Studs  30 Studs Total.
: 6.       Crossover Hi Hat Studs  52 Studs Total.
~   Inner Cylinder Shell Studs 55 Studs Total.
: 8.        H.P.'oupling Studs 20 Studs Total.
: 9.      Stop Valve Pilot &, Mummy Studs 24 Studs Total.
: 10.       Outer Cylinder Shell Studs 52 Studs Total.
11        Jack Shaft Thrust Studs 30 Studs Total.
          '2 Cross Pipe Vertical Joint  44 Studs Total.
          '3 Crossover Pipe Diaphragm  52 Bolts Total.
          '4.
Crossover Studs 5 Studs Total.
: 15.       Inner Cylinder 17 Studs Total.
: 16.        Control Valve Tension Bolts 2 Bolts Total.
17 Blade Ring 4 Studs Total.
          '8.
Stud 688J343-19 25 Studs Total.
: 19. Inner Shell Studs 682J249-23 2 Studs Total.
: 20. Inner Shell Studs 682J343-21 4 Studs Total.
21        Inner Shell Studs 682J343-16 4 Studs Total.
        '2 Upper Studs 885J343-19 25 Studs Total.
        '3 Inner Shell Studs -'82J342-15 12 Studs Total.
        '4
        ~      Miscellaneous Turbine Studs 120 Studs Total.
E. Liciuid Penetrant and Ultrasonic Examinations:
: 1. Upper       Babbitt,
: 2. Lower       Babbitt.
 
II~
                ~Wor $ 4eceests   ~WR~P The following examinations       were performed     in support of Engineering Work Requests (EWR's).
A. Visual Examinations:
: 1. 1/2" Valves 1032-1       &, 1032-2, Cleanliness-EWR 4613.
the Joint   "Prep" Joint, g3. Burr removed and verified by
        'luor 20" Daniel   QC personnel Accepted.
: 2.       Service Water Header, Cleanliness-EWR 4930.
B. Radio ra hic Examinations:
: 1. Containment     Penetration     2 Welds     EWR 4998 '
and Linear Indications. Repaired, Re-examined and Accepted.
C. Visual and Ultrasonic Examinations:
: 1. Heater Drain Tank Pump Barrels             "A" 8L "B" EWR   5053.
The following examinations       were performed     in support of Maintenance Work Orders (MWO's).
A. Visual Examinations:
: 1. CV Equipment Hatch       Geneva Latch Plug Welds.
: 2. CV Floor Grating       Tack Welds.
: 3. Pressurizer Safety Line Nuts for Valves 434 &, 435 Replacements (48 nuts &. 93 studs accepted).
Q Contained Axial Cracks in Hex Head, 2 Nuts Contained Thread Damage that Prevented Engagement on Stud.
B. Ultrasonic Thickness Examinations:
: 1. H.P. Turbine Drain Lines           Pipe &, Fittings     Wall Thickness.
C. Visual and L'iciuid Penetrant Examinations:
: 1. 3/4" Nitrogen Supply to AOV-846, 8 Socket Welds.
: 2. Charging Pump "A" - 3/4" Valve 281C &, Piping - 8 Welds.
: 3. Safety Injection Pump "B" 3/4" Nipple to Elbow Weld.
: 4. MSIV 3516       Lug & Nut Locking Weld.
 
1 .e a',q
: 5. MS Non-return Check Valve 3518B     Disc Stop Welds.
Re-Examined   after Repairs-Acceptable.
: 6. MS Non-return Check Valve 3519A Disc Stop Welds.
Re-Examined after Repairs-Acceptable.
: 7. "A" &, "B" Service Water Pressure Gage     Header -Pipe Coupling Welds. (1" pipe to coupling     to 20" pipe) 8 ~ Charging   Pump "A",   Valve 285 to Pipe Weld.
: 9. Charging   Pump "B",   Valve 284 to Pipe Weld.
                            "C",
: 10. Charging Weld Pump      
                                                /"
Valve 283 to Pipe Weld.
Centerline. Reexamined after repairs   ,
                                                            /
accepted.
D.
k.
The
    ~
Liciuid Penetrant and ~Ma netic Particle Examinations:
1 ~
          "A" Preseparator 16" Diameter Pipe Replacement 3 Welds.
miscellaneous work.
A.
e following examinations were performed in support of Visual Examinations on Welds:
1, Astregal Plate Welds Fire Door &#xb9; 23.
: 2. Skin Repair Fire Door &#xb9; F-500.
: 3. Heater Drain Tank at Valve 3098, 1/2" Socket Welds 3 Welds.
: 4. Freeze Plugs in Nitrogen Supply Lines.
: 5. "B" Reactor Coolant Pump Insulation Support Welds.
6, Steam Generator Blowdown Socket Welds.
: 7. DI System - Valve 8419 Valve Cap.
: 8. Steam Generator Blowdown Valve 5701, 2 Welds.
: 9. "B" Steam Extraction Line 5 Welds.
: 10. Check Valve 4023 Tack Welds.
: 11. Personnel Hatch Outer Door Geneva Latch Plate Plug Weld.
: 12. Steam Generator Blowdown Valve 5735 8 Socket Welds.
: 13. Equipment Hatch Rollup Door Channel to Plate, Angle and Lug ~
: 14. "B" CCW Pump Motor Stand to Base Plate.
B. Visual Examinations     on Com onents:
: 1. Class 2 Valve Upgrade for Henze Valve Nuts.
: 2. Valve Stem Feedwater Valve 4269.
: 3. Steam Generator Primary Manway Washers 201 Washers Accepted.
Re 'ectable   2 Washers Contained Machine Cuts on ID Surface.
 
s t4r .
Ci P'1 yr
 
4,         Steam Support S-4, Re-exam for NCRG89-365.
: 5. Service Water Headers Screen House Min Wall     & Surface Condition.
: 6. Service Water 20" Header Pipe Downstream of Support 7
          'ain
          ~
SWU-616.
Fire Doors &#xb9;37, &#xb9;46, &#xb9;27, &#xb9;26, &#xb9;79, &#xb9;61 and &#xb9;62 Fillet Welds.
: 8. Service Water Screen House Surface Condition Downstream from Valve 4606'.
                                      / "
                                                /
Wall Thickness Resulted in Identifying Wall to be 0.355" Thick. Remaining Wall Thickness is 0.305". Wall Loss at This Area 14X.
9  ~ Service Water Screen House Surface Condition Downstream from Support SW-620.
Re ectable Random Pitting and Undercut Around Entire Circumference. Pitting 8 to 17X of Wall Thickness ( 1/64" to 1/16" Deep).
10    "A" Service Water Pump 2 Rigid Restraints.
C. Liciuid Penetrant Examinations on Com onents:
: 1. Ten Inch (10") SI Line, 2" Weld-0-Let " to Pipe.'
                                                            /
90-102 Generated. Defects were Repaired by Blending, Re-.
examined -Acceptable.
: 2. Freeze Plugs for Leakage Examination on Pipe 2 Areas.
: 3. Main Feedwater Pump Shaft &, Impeller.
: 4. Feedwater Valve 4272 Seat Examination.
: 5. Low Pressure Steam Extraction Bellows Welds.
6,. Valve 4270 - Stem, Seats,     Plug &, Gage.
: 7. Valve &#xb9; 390 Filter Vent Socket Weld.
: 8. CVCS Pipe to Valve &#xb9; 390.
: 9. Hanging Scaffolds, Al, A2, Bl, B2 & B3, 25 Welds Total.
Re 'ectable -Linear Indications in Bl &" B2. These welds are to be repaired and reexamined before the 1991 AI&0,
: 10. Bolts from Check Valves 870A, 870B, 889A & 889B.
D. ~Ma netic Particle Examinations     on Com onents:
1 ~ Auxiliary Feedwater Valve   4017 Seat Area.
NCR 90-96 was Generated. Defects were Repaired and Re-examined -Acceptable.
: 2. L.P. Steam Extraction to 2A Heater Bellows.
: 3. Steam Extraction Pipe to Elbow Welds.
: 4. Steam Extraction to 5A &, 5B Heaters Reducer Welds (2).
: 5. Blowdown   to Blown Tank   Component 80 Pad Weld.
E. Ultrasonic Examinations on Com onents:
: l. Auxiliary Feedwater-Three Supports-Verify Bolt Lengths.
: 2. 1A &. 1B Diesel Generators-Ductwork-Verify Bolt Lengths.
: 3. Spent Fuel Pit "A" - Verify Bolt Support AFW-600, Verify Bolt Lengths.
Lengths'.
 
I ~
4g
    -S A
Pl t4 rr t
jg I
: 5. Support SWU-623, Verify Bolt Lengths.
6, Service Water 14" Diameter Pipe Wall Thickness.
: 7. Support SWU-625, Verify Bolt Lengths.
: 8. S/G "A", Swirl Vane Wrapper- Wrapper Thickness.
Generated. Fabricated and     Installed   7 Impingement Plates on Severely Eroded Areas.       Use-As-Is on Feedwater Tee Erosion. A Monitoring Program Initiated for the Feedwater Tee 8c Steam Generator Wrapper Erosion not Repaired in. the 7 Areas Above.
: 9. S/G "B", Swirl Vane Wrapper- Wrapper Thickness.
Re 'ectable Wrapper Thickness Eroding, NCR 90-124 Generated, Action Taken was Incorporated into Item 48 Above.
: 10. Sampling Line at AOV 5736 Wall Thickness.
: 11. Service Water Support SWU-631, SWU-632, SWU-633 and SWU-634,   Verify Bolt Lengths.
: 12. Service Water Support SWU-568,     Verify Bolt Lengths.
F. Visual and Liciuid Penetrant Examinations on Com onent.s:
: 1. RHR System By Valve 687B - Sock-o-let Weld.
: 2. Service Water Header Valve 4799 2 Welds, Coupling, and "Prep" Areas.
G. Visual and   ~Ma netic Particle   Examinations on   Com onents:
: l. "A" S/G - Swirl Vane Wrapper Patches.
Generated,   Action Taken   was Incorporated into Items 48 & 9   in Paragraph E Above.
: 2. Main Steam System     Valve 3411     Flange Seal Area.
H. Visual   ~Ma netic Particle   F. Ultrasonic Examinat.iona   on Com   onents:
: 1. Retaining Block Studs     Baseline for Valves 870A, 870B, 880A and 880B.
    ~
: 1. Pipes and Elbows in the Min-Wall (Wall Thickness) Program.
: 2. "B" Reactor Coolant Pump Insulation Support Bushings.
: 1. Service Water Elbow Downstream of Valve 9633B.
: 2. Standby Auxiliary Feedwater -Pipe by Support SWO-508 0.207" Thickness, 1"
: 1. 3/4," Chemical Feed  Line to "A" S/G Feedwater.
Angle Iron. Missing Nut on U-Bolt.
 
b
/fan}}

Latest revision as of 10:53, 4 February 2020

Rev 0 to, Inservice Insp Rept for Third Interval (1990-1991),First Period,First Outage (1990) at Re Ginna Nuclear Power Plant.
ML17261B139
Person / Time
Site: Ginna Constellation icon.png
Issue date: 07/13/1990
From:
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17261B138 List:
References
NUDOCS 9008230232
Download: ML17261B139 (236)


Text

ROCHESTER GAS AND ELECTRIC CORPORATION 89 EAST AVENUE, ROCHESTER, NEW YORK 14649 INSERVICE INSPECTION REPORT FOR THE THIRD INTERVAL (1990 1999)

FIRST PERIOD~ FIRST OUTAGE (1990)

AT R. E. GINNA NUCLEAR POWER STATION REVISION 0 JULY 13, 1990 9008230232 900817 Ii PDR ADOCK 05000244 Q PDC

A GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990 1999 Interval, First Outage 1990 Table of Contents Introduction and Synopsis Summary of Work Accomplished Class 1 Components Class 2 Components Class 3 Components High Energy Components Design Break Weld Examinations Consequential Break Weld Examinations Component Support Examinations Steam Generator System Pressure Tests Hydrostatic Testing Leakage Testing Snubber Program Visual Examinations Functional Testing Repair/Replacement Program Repairs Service Induced Rejectable Indications Code Rejectable Indications Replacements Erosion/Corrosion Program Attachment I ISI Program Summary Attachment II Erosion/Corrosion (Minwall) Program Summary Attachment III Miscellaneous NDE Summary

l GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990 1999 Interval, First Outage 1990 INTRODUCTION AND SYNOPSIS:

Inservice Inspection (ISI) activities during the 1990 Refueling Outage were performed on components of Class 1, 2, 3, High Energy Pipi'ng, Steam Generator Tubes and Snubbers. The examinations were initiated on 12 March 1990 and activities concluded on 7 May 1990. Examination methods included Visual Examination (VT), Liquid Penetrant Examination (PT), Magnetic Particle Examination (MT), Ultrasonic Examination (UT),

Radiographic Examination (RT), Eddy Current Examination (ET),

Functional Testing (FT) and System Hydrostatic Pressure and Leakage Tests.

Personnel involved included the RG&E Materials Engineering and Inspection Services Section., Southwest Research Institute, Gilbert Commonwealth, Allen Nuclear Associates, NDE Technologies, Ginna Station Quality Control and the Ginna Station Results/Test Group.

Additional Support Personnel involved, included individuals from the following departments: Ginna Station Insulators, Maintenance, Electricians, Pipe Fitters, Health Physics, Turbine Maintenance, RG&E's General Maintenance and the Mechanical Engineering Group of the Engineering Department.

~SMMARY OF ~WOR ACC M LISHED:

Note: A detailed summary of all components with associated results can be found in the Attachments.

I!

  • A total of 63 Class 1 components were examined during the 1990 Outage. The examination for these components consisted of 20 VT-1's, 11 VT-3's, 36 PT's, 3 MT's,,l RT, and 22 UT's. A total of 93 examinations were performed on Class 1 components.

Class 1 examinations were performed on the following components and/or system lines:

Pressurizer.

Steam Generators.

Regenerative Heat Exchanger.

10" Pressurizer Surge Line; 10-RC8-2501 2" Auxiliary Spray Line; 2-CH5-2501 10" Safety Injection Line; 10A-SI2-2501A

'h 6" Safety Injection (L.P. ) Line; 6A-RC-2501-B 4" Safety Injection (L.P.) Line; 4A-RC-2501-B 6" Safety Injection (L.P.) Line; 6A-RC-2501-A 2" Safety Injection Loop A Line; 2C-SI2-2501 2"

2" Safety Injection Loop B Line; 2B-SI2-2501 Letdown Line; 2B-RCO-2501-A 2" Letdown Line; 2A-RCO-2501-B 2" Letdown Line; 2A-CH4-2501 2" Charging Line; 2B-CH5-2501 2" Alternate Charging Line; 2A-CH5-2501 Reactor Coolant Pump B.

Reactor Coolant Pump Spare Flywheel.

Valves.

~SASS 2 CO PO ENTS' total of 75 Class 2 components were examined. The examination for these components consisted of 7 RT's, 19 UT's, 32 PT's, 14 MT's, 2 UTTK (Thickness Measurement), 10 VT-1's> and 35 VT-3's for a total of 119 examinations.

Class 2 examinations were performed on the following components and/or system lines:

Non-Regenerative Heat Exchanger.

Seal Water Heat Exchanger.

Reactor Coolant Filter.

Pulse Dampener Line;, 8A-CH-2502.

Seal Water Injection Filters.

Main Steam Loop A Line; 30A-MS-600-1A.

Main Steam Loop A Line; 6B-MS-600-1A.

Main Steam Loop B Line; 30B-MS-600-1B.

Feedwater Loop A Line; 14A-FW-900-1A.

Feedwater Loop B Line; 14B-FW-900-1B.

L.P. Safety Injection; Line 10-SI-151.

L.P. Safety Injection; Line SA-SI-301B.

LE P Safety Injection; Line SA-SI-151.

L.P. Safety Injection; Line 8B-SI-151.

L.P. Safety Injection; Line SD-SI-301.

LE PE Safety Injection; Line 6-AC-601.

L.P. Safety Injection;.Line 6A-AC-601.

L.P. Safety Injection; Line 4A-SI-301.

H.P. Safety Injection; Line 4D-SI-1501.

H.P. Safety Injection;. Line 4E-SI-1501.

H.P. Safety Injection; Line 3B-SI-1501.

H.P. Safety Injection; Line 3C-SI-1501.

H.P. Safety Injection; Line 3E-SI-1501 Safety Injection; Line 2A-SI-1501. '.P.

H.P. Safety Injection; Line 2D-SI-1501>>.

Residual Heat Removal; Line SFF-AC-601.

Residual Heat Removal; Line 6K-AC-151,

Residual Heat Removal; Line 10B-AC-601.

Residual Heat Removal; Line 10D-AC-601.

Residual'eat Removal; Line 10A-AC-601.

Residual Heat Removal; Line 10H-AC-601.

Residual Heat Removal; Line SC-AC-601.

Residual Heat Removal; Line 6C-AC-601.

Residual Heat Removal; Line SX-AC-601.

Containment Spray; Line 6C-SI-301.

Containment, Spray; Line 6E-SI-301.

A total of 21 Class 3 components were examined by the VT-3 visual technique, Class 3 component examinations were performed on the following system lines:

Component Coolant Pumps Discharge to Component Coolant Heat Exchanger Line: SB-AC5-152.

Service Water to Component Cooling and Spent Fuel Pit Heat Exchangers Line: 20A-SWO-125-9.

Service Water Intermediate Building to A 8c B Chillers Line:

6B-SW0-125-9.

Auxiliary Feedwater Pumps Discharge-Intermediate Building Line: 3A-FW7-900-1B.

Standby Auxiliary Feedwater from Penetration 119 to A S/G Feedwater Header.

Standby Auxiliary Feedwater From Penetration 119 to Auxiliary Feedwater Pump C Line: 3A-FW8-902-A.

Standby Auxiliary Feedwater from 'Penetration 123 to B S/G Feedwater Header.

Standby Auxiliary Feedwater Service Water Supply to Standby Auxiliary Feedwater Pump D Line: 4A-FW8-152-B.

Twenty Three (23) High Energy Piping components were examined during the 1990 Outage. The examinations for these components consisted of 16 VT-1's, 6 VT-3's, 6 PT's, 18 MT's, 11 UT's, 1 UTTK and 16 RT's for a total of 74 examinations.

High Energy component examinations were performed on the following system lines:

~Desi n Break Weld Examinations:

Main Steam Loop A Outside Containment, Line: 30A-MS-600-1A.

Main Steam Loop B Outside Containment, Line: 30B-MS-600-.1B.

Feedwater Loop A Outside Containment, Line: 14A-FW-900-1A.

Feedwater Loop B Outside Containment, Line: 14B-FW-900-1A.

sn Conse uential Break Weld Examinations:

Main Steam Loop A Outside Containment, Line: 30A-MS-600-1A.

Main Steam Loop B Outside Containment, Line: 30B-MS-600-1B.

Main Steam Turbine Building, Line: 24A-MS-600-1A.

Feedwater Turbine Building, Line: 20-FW-900-1.

Feedwater Turbine Building, Line: 8-FW-900-1.

Feedwater Loop A Outside Containment, Line:'4A-FW-900-1A.

Feedwater Loop B Outside Containment, Line: 14B-FW-900-1B.

Main Steam, Line: 36-MS-600-1.

Main Steam, Line: 24A-MS-600-1A.

Main Steam, Line: 24B-MS-600-1B.

Feedwater, Line: 14A-FW-900-1A.

Feedwater, Line: 14B-FW-900-1B.

STEAN GENERATOR ~BING:

Eddy Current Examinations were performed on tubes in the A and B Steam Generators.

The following Eddy Current examinations were performed during the 1990 Outage:

1 ~ Open Generator Tubes, Previously identified degradation greater than 20%.

2 ~ Open Generator Tubes, 20% Minimum, Rotating Random Sample Full Length (Total).

3 ~ Open Generator Tubes, 100% of all unsleeved tubes.

Hot Leg Tube End through First Tube Support Hot Leg.

4, Sleeved Generator Tubes, 20% Random Sample of each type.

Sleeve End to Sleeve End (minimum).

5. MRPC of Row 1 U-Bends and Row 2 U-Bends that are a part, of the 20% Random Sample Full Length.

The following information summarizes the initial pre-outage and post-outage tube status as well as the planned and completed Eddy Current work scope for Steam Generators A 8I B.

STEAM GENERATOR A:

Total Tubes 3260 Out of Service (plugged) 173 Sleeved Tubes 172 Open Unsleeved Tubes 2915

Req'd Number Number Min ~Pro m'd ~Ins t'd Com leted Hot, Leg to ¹1 TSP 2915 2915 2915 100.0%

Full Length (20X Random) 583 586 585 100.3X Previous Ind. > 20% 100 OX Sleeves 35 36. 35 100.0%

Total Tubes 3260 Out of Service (plugged) 197 Sleeved Tubes 223 Open Unsleeved Tubes 2840 Note: A total of 75 tubes were repaired.

( 51 sleeved R 24 plugged = 75 repairs)

STEAM GENERATOR B:

Total Tubes 3260 Out of Service (plugged) 340 Sleeved Tubes 642 Open Unsleeved Tubes 2278 Req'd Number Number X Min ~Pro m' ~In s t' Com leted Hot Leg to ¹1 TSP 2278 2278 2278 100.0X Full Length (20X Random) 456 461 460 100.9%

Previous Ind. > 20X 19 19 19 100.0X Sleeves 129 131 131 101.6X Deplugged Tubes (F/L) 28 28 28 100 OX

u~C

Steam Generator "B" Post-Outa e Tube Status:

Total Tubes 3260 Out of Service (plugged) 332 Sleeved Tubes 832 (~)

Open Unsleeved Tubes 2096 Notes: A total of 211 tubes were repaired.

(191 sleeved &, 20 (4) plugged = 211 repairs)

(4) = One previous post-outage B&W Sleeved Tube was plugged and is included in the'20 tubes identified in the above note.

Eddy Current Examination details are documented in the "Summary Examination Report for the 1990 Steam Generator Eddy Current Inspection".

SYSTEM PRESSURE ~EST:

H drostatic:

Four (4) Hydrostatic tests and associated VT-2 examinations were performed during the 1990. Outage.

Hydrostatic tests were performed on the following:

Procedure Discre tion RSSP-15.7.1 Charging System through Regenerative Heat Exchanger.

RSSP-13.16 CVCS Hold-up Tank "A".

RSSP-13.17 CVCS Hold-up Tank "B".

RSSP-13.18 CVCS Hold-up Tank "C".

Two Hydrostatic examinations were scheduled for the 1990 outage but were not performed. One'xamination was scheduled in error and was subsequently rescheduled for the correct outage, The second examination scheduled pertained to a non-class vessel and associated piping that was initially performed during the Second Interval ISI Program. The associated examination boundary is not under the jurisdiction of Appendix B of the Quality Assurance Manual and was removed from the Third Interval ISI Program.

Two Leakage Examinations'ere performed during the 1990 Outage and are listed below:

Reactor Coolant System Leakage Examination (PT-7)

Containment Spray Rings

Five (5) Leakage examinations were also performed to fulfill the Second Interval Program when Ginna Station was placed back in service in 1989. The Leakage examinations included the following.

CVCS Hold-Up Tanks &, Piping.

CVCS Charging R Letdown outside Containment.

CVCS Boric Acid Storage Tanks R Piping.

CVCS Boric Acid Evaporizer - Demineralizers ~

Diesel Generators.

~NBBER ~PR GRA Visual Examinations:

A total of 147 Snubber components were inspected that required 148 VT-3 examinations. These examinations were performed to satisfy Ginna Station Technical Specification requirements.

A Mechanical Snubber on the Feedwater Loop "B" System; FWU-54, was rejected during the close of the 1989 Outage. This component was reviewed by Engineering under NCR G89-743 and resulted in a "use-as-is" determination.

Snubber examinations were performed on the following components and/or system lines:

Steam Generator "A".

Steam Generator "B".

Turbine Driven Auxiliary Feedwater Pump Suction Line: 4A-SW-125-1.

Auxiliary Feedwater Pump Discharge Intermediate Building Lines: 3D-FW7-900-1 ~

3A-FW7-900-1A.

3J-FW7-900-1.

3A-FW7-900-1B.

3A-FW-900-1A.

Steam Generator 1B Blowdown Line: 2C-MS-600-1B.

Auxiliary Cooling Line: 3C-AC-152.

Auxiliary Cooling System from Pump Cooling Outlet to Penetration 126 Line: 3E-AC6-152 Cooling Line: 4B-AC-152. 'uxiliary 2-IN..Letdown Line: 2A-CH4-2501.

2-IN. Alternate Charging Lines: 2-CH-2501R.

2A-CH5-2501.

CVCS Letdown Line: 2G-CH-601.

Reactor Coolant Pump "B" Seal Water Line: 2AB-CH-2502.

Reactor Coolant. Pump "A" Seal Water Line: 2U-CH-151.

CVCS Letdown Line: 2H-CH-601.

CVCS Letdown Line: 2N-CH-151.

Feedwater Loop "A" Line: 14A-FW-900-1A.

Feedwater Loop "B" Line: 14B-FW-900-1B.

Main Steam Loop "A" Line: 30A-MS-600-1A.

Main Steam Loop "B" Line: 30B-MS-600-1'

'I fc

Main Steam Loop "B" Riser Line: 6B-MS-600-1B.

Main Steam Loop "A" Riser Line: 6B-MS-600-1A.

Main Steam Supply to Auxiliary Feedwater Pump Turbine Lines: 6B-MS-600-1.

6A-MS-600-1.

Low Head Safety Injection Line: 6-AC-601.

Residual Heat, Removal Line: 10A-AC7-2501-A.

Residual Heat Removal Line: 8B-AC-601.

. Residual Heat Removal Line: 10-AC-601.

Residual Heat Removal Line: 6D-AC-601.

Residual Heat Removal Line: 10E-AC-601.

Residual Heat Removal Line: 10G-AC-601.

Safety Injection Line: 10GG-AC-601.

Residual Heat Removal Line: 10D-AC-601.

Safety Injection Line: 6K-AC-151.

Safety Injection Line: 10-SI-151.

Safety Injection .Line: 4-SI-301.

Safety Injection Line: 8H-SI-151.

Safety Injection Lines: 10A-SI2-2501-B.

10A-SI2-2501-A.

Residual Heat Removal Line: 10A-AC7-2501-B.

Service Water to A8rB Diesel Generator Water Coolers Lines: 10B-SW0-125-9.

8G-SW0-125-9B.

Service Water Intermediate Building From 16" Header to Penetrations 312-320 Line: 8A-SW0-125-9.

Standby Auxiliary Feedwater from Penetration 123 to B S/G Feedwater Header Line: 3-FW-900-1B.

Standby Auxiliary Feedwater from Penetration 119 TO A S/G Feedwater Header Line: 3-FW-900-1A.

Pressurizer Relief from Pressurizer to Relief Manifold Lines: 6AP-RC-602.

6BP-RC-602.

Power Pressurizer Relief Lines: 3BP-RC-602.

3BP-RC-2501.

Functional ~Teatin A total of 15 Snubbers were Functionally Tested (FT) during the 1990 outage. Twelve of the Fifteen Supports were Mechanical Snubbers and the remaining three were Hydraulic Snubbers. One Snubber AFU-227 was originally scheduled for functional testing but was substituted by AFU-109 during the outage, Snubber Functional Testing (FT) was performed on the following components and/or system lines:

Steam Generator "A".

Auxiliary Feedwater Pump Discharge, Lines: 3A-FW7-900-1B 3A-FW-900-1A Reactor Coolant Pump 1B Seal Water, Line: 2AB-CH-2502.

Chemical 8c Volume Control System Letdown, Line: 2H-CH-601 Feedwater Loop "A", Line: 14A-FW-900-1A Feedwater Loop "B", Line: 14B-FW-900-1B Residual Heat Removal System, Line: 10G-AC-601 Safety Injection, Line: 10A-SI2-2501-B Pressurizer Relief from Pressurizer to Relief Manifold, Line: 6BP-RC-602 Power Pressurizer Relief, Line: 3BP-RC-602 REPAIR PROGRAM:

The Repair Program as described under the Ginna Station Quality Assurance Manual Appendix B identifies the component jurisdiction and associated requirements. The Rochester Gas &,

Electric Repair Program for Ginna Station covers both Servic'e Induced and Code Rejectable Repairs. A "Service Induced Reject" occurs when an item that is under Appendix B jurisdiction contains an indication that is beyond acceptable standards that was caused during its'nservice life. A "Code Reject" occurs when an item that is under Appendix B jurisdiction contains indications or other rejectable conditions that were not service induced. Code rejects include but are not 'limited to items such as arc strikes or tightening of loose bolting.

Three service induced rejectable components were identified during the 1990 Outage. The following listing provides a summary of the component and the associated exp'anded examination scope.

ASME Class: 1

~S etem: 2" Alternate Charging Line: 2A-CH5-2501 Com onent: Variable Spring, CVU-51 A 3/4" rod was bent from the vertical position. NCR 90-167 was generated and corrective action taken. The rod was replaced under Work Order ¹ (WO¹) 9021606. This support was reexamined and acceptable.

~Ex anded Examination ~Sco e:

The following components were examined on the system:

1. Support CVU-50, "U-Bolt" type: Examination revealed no other service induced recordable indications.
2. Support CVU-5, Variable Spring: Examination revealed no other service induced recordable indications.

II. ASME Class: 2

~S stem: Low Pressure Safety Injection Line: SB-SI-151 The Rod in the Spring Can is locked the space in front 85 of the can is 1/2" while the rod touches the rear of the can. NCR 90-091 was generated for Engineering disposition. Work Order (W04) 9021614 was initiated to correct the situation. The support, was reexamined'with no recordable indications and acceptable.

~Ex ended Examination ~gco e:

The following components were examined on the system:

1. Support RHU-101, Rigid Support: Examination revealed no other service induced recordable indications.
2. Support RHU-130, Variable Spring: Examination revealed no other service induced recordable indications.

1 III. ASME Class: 2

~S stem: High Pressure Safety Injection Line: 3E-SI-1501 Com onent: Rigid Support, SIU-58 Code Service Induced Re 'ectable Indication:

A loose nut was identified on top of the support while the associated bottom nut can be turned by hand. NCR 90-107 was generated for Engineering disposition. Work Order (W04) 9021810 was initiated to perform the repairs. The support was reexamined after repairs and acceptable,

~Ex ended Examination ~Sco e:

The following components were examined on the system:

1. Support SIU-57, Rigid Support: Examination revealed no other service induced recordable indications.
2. Support SIU-59, Rigid Support: The Examination revealed no other service induced recordable indications.
3. Support SIU-66> Rigid Restraint: Examination revealed no other service induced recordable indications.

fp Code The following .listing of 40 components provides an accounting of Code Respectable Indications identified during the 1990 Outage.

ASME Class: 1

~S stem: Low Pressure Safety lnjeotion System:

Line: 6A-RC-2501-B Slag inclusions located in the crotch area were identified in the Northeast and Southeast Lug Plates. NCR 90-163 was generated. An Engineering evaluation was performed that resulted in a use-as-is disposition.

2 ~ ASME Class: 1

~S stem: 2" Safety Znjeotion Loop A Line: 2C-SI2-2501 Code Re ectable Indication:

A rough weld with numerous pores on the weld center line was identified. NDE personnel "blended out" the indication with a file. The area was reexamined after blending and acceptable.

3 ~ ASME Class: 2

~S stem: Main Steam Loop A Line: 30A-MS-600-1A Com onent: Anchor in Penetration 401(outside containment),PS-A Code Re ectable Indication:

Lack of thread engagement was identified and reported on NCR 90-186. Engineering reviewed and performed an evaluation with a resulting disposition of use-as-is.

4 ~ ASME Class: 2

~S stem: Feedwater Loop A Line: 14A-FW-900-1A Coin onent: Variable Spring, FWU-1 The top nut does not have full thread engagement. NCR 90-173 was generated. Engineering review of this reportable condition indicated that that had a disposition of it was addressed under NCR G83-132 use-as-is, acceptable.

~ '

1i f'

<( >

lw

S. ASME Class: 2

~S stem: Low Pressure Safety Injection System Line: SA-SI-301B This Inspection identified loose Micarta block on the North side of the guide. NCR 90-160 was generated for Engineering review. A use-as-is disposition was based on the pipe to block gaps being within the requirements with the associated nuts tack welded in place as addressed by FCR-3092-145 dated 5-11-87.

6. ASME Class: 2

~S stem: Residual Heat Removal System Line: 10B-AC-601 The examination reported linear respectable indications in the weld. Additional augmented NDE investigation revealed that the indications were actually score marks that appeared to be mechanical in origin. The final disposition of this weld is acceptable.

ASME Class: 2

~S stem: Low Pressure Safety Injection System Line: 4A-SI-301 Code Re 'ectable Indication:

The Integral Welded attachment to the Elbow pressure boundary was 'not welded all around. NCR 90-164 was generated for Engineering review and evaluation. A disposition of use-as-is was made based upon the adequacy of the existing weld.

8. .ASME Class: 2 I

~S stem: High pressure Safety Injection System Line: 3E-SI-1501 L

Examination revealed that the ear on the pipe clamp is bent inward. NCR 90-247 was generated for Engineering review and evaluation. The replacement of the clamp was performed under WO¹ 9021837. Reexamination of the component was acceptable.

fr"j'f ASME Class: 2

~S stem: High Pressure Safety Injection System Line: 3E-SI-1501 Examination revealed that a bushing was located in the upper clamp section while none were located in the lower clamp. NCR 90-090 was generated for review and disposition.

Quality Control revealed that the bushing is a spacer and only required on one bolt. The component is acceptable, use-as-is.

ASME Class: 2

~S stem: Containment. Spray System Line: 6E-SI-301 Code Re 'ectable Indication:

The Integrally Welded attachment to the pressure boundary is missing 1.5" of weld in the crotch area, an arc strike is also situated adJacent to the weld. NCR 90-089 was generated for Engineering review and evaluation.

of use-as-is on the missing weld was based on Engineerings'isposition EWR 2512 design analysis, ME 39 Attachment Bl. The respectable arc strike was removed under WOg 9021570. Subsequent reexamination was acceptable.

ASME Class: High Energy Program Appendix B

~S stem: Feedwater Loop B Out.side Containment.

Line: 14B-FW-900-1B Code Re 'ectable Indication:

A rejectable Linear Indication 1/4" long was identified and reported on NCR 90-123. A disposition for repair employing a metal removal method was initiated under WOg 9021386.

Reexamination after the repair activity was acceptable.

ASME Class: High Energy Program Appendix B

~S stem: Feedwater Outside Containment Line: 14A-FW-900-1A Com onent: Mechanical Snubber, FWU-21 This support was rejected due to insulation obstructing the snubber movement. The insulation, was tight against the snubber, 6" away on the clamp side. NCR 90-200 was initiated to resolve the situation. Engineering dispositioned the NCR as rework and instructed that the clamp be moved and rotated to insure that the final clamp position will not restrict the snubber freedom of movement in the hot position. Reexamination of the support was acceptable. P

$t ASME Class: 3

~S stem: Service Water to Component Cooling A Spent Fuel Pit Heat Exchangers.

Line: 20A-SWO-125-9 Four(4) bo'its were identified and rejected for being 1/8" short of full thread enga'gement. NCR 90;090 was generated for Engineering review. Upon Engineerings'eview 85 evaluation, a use-as-is disposition was made due to the associated loads are in compression.

ASME Class: 3

~S stem: Auxiliary Feedwater Pump Discharge Intermediate Building.

Line: 3A-FW7-900-1B Code Re 'ectable Indication:

Inspection revealed that the support did not conform to the drawing requirements. NCR 90-108 was initiated and reported to Engineering for disposition. Engineering review indicated that Revision 1 of the drawing should have been used. The support is acceptable as is and agrees to Revision 1 drawing requirements.

ASME Class: 3

~S stem: Standby Auxiliary Feedwater from Penetration 119 to A Steam Generator Feedwater Header, Line: .3C-FW-900-1A Com onent: Variable Spring, AFW-30 The inspection revealed that the can setting of 580 lbs.

did not agree with the 540 lbs. identified in ME-256 Specification. NCR 90-185 was generated for Engineering review. The disposition initiated work to reset the spring can-to resolve the discrepancy. Reexamination i'ndicated no recordable indications, acceptable.

ASME .Class: 3

~S stem: Standby Auxiliary Feedwater from Penetration 123 to B Steam Generator Feedwater Header.

Line: 3C-FW-900-1B Code Re ectable Indication:

Results of the inspection revealed that the support cold setting of 2 1/8" should be 3 1/2". NCR 90-109 was generated.

A review of the data by Engineering indicated that the Gilbert Scales show the setting to be 2 1/2". The reading of 2 1/8" is acceptable. ME-256 Specification for this component will be corrected and revised.

(14)

j t

17. ASME Class: 3

~S stem: Standby Auxiliary Feedwater , Service Water supply to Standby Auxiliary Feedwater Pump D.

Line: 4A-FWS-152-B Oode Re 'ectable Indication:

Bottom lug weld on the East side has lack of sufficient weld at the toe. NCR 90-188 was generated to resolve this problem. Engineerings'isposition indicated that repairs are required. Upon completion of repair activities, a reexamination of the component was performed and acceptable.

This repair was performed on a component under the jurisdiction of "Construction". This component is not under the jurisdiction of Appendix B until "Construction" rework turnover.

18. ASME Class: Snubber Program Appendix B

~S stem: Auxiliary Feedwater Pumps Discharge, Xntermediate Building.

Line: 3A-FW-900-1A

\

Inspection revealed that the bolt holding the fluid reservoir was loose. NCR 90-104 was generated. Corrective action was performed by replacing the support with another Snubber under WO ¹9020415. Reexamination of the support was acceptable.

19. ASME Class: Snubber Program Appendix B

~S stem: Feedwater Loop A Line: 14A-FW-900-1A The top of the Snubber was hitting the mounting brackets.

NCR 90-246 was generated to document this condition.

Engineering performed an evaluation and dispositioned the condition use-as-is. The disposition of use-as-is was based on the angular tolerance and clearance on the snubber being adequate to perform its function.

20. ASME Class: Snubber Program Appendix B

~S stem: Feedwater Loop B Line: 14B-FW-900-1B Insulation on valve 4012 was resting on the snubber that may interfere with and cause binding of the snubber during operation. NCR 90-103 was generated to resolve this situation. Engineering disposition of reduceing the thickness of the insulation on the valve in order to provide the needed clearance was performed. Reexamination after repairs was acceptable.

(15)

21. ASME Class: Snubber Program Appendix B

~S stem: Feedwater Loop A Line: 14B-FW-900-1B The Inspection revealed that the locknut was not tight on the snubber side, the cotter pin was missing and a turnbuckle on the component was not shown on the drawing. NCR 90-172 was generated. Repairs were initiated to correct the reported items. The snubber was reexamined after repairs and found to be acceptable.

22. ASME Class: Snubber Program Appendix B

~S stem: Main Steam Loop A Line'. 30A-MS-600-1A The snubber was installed backwards to the way the drawing indicated. NCR 90-101 was generated for Engineering evaluation. The'esults of the evaluation indicated that the snubber may be rotated 180 degrees without changing its function. A disposition of use-as-is was made.

23 'SME Class: Snubber Program Appendix B

~Sstem: Safety Injection System Line: 10A-SI2-2501-A Code Re ectable Indication:

The inspection revealed that the snubber tang was binding on the pipe clamp. NCR 90-187 was initiated to address this problem. A repair was performed and the snubber was subsequently reexamined and found acceptable.

24. ASME Class: Snubber Program Appendix B

~S stern: Service Water to A ik B Diesel Generator Water Coolers.

Line: 10B-SWO-125-9 The examination indicated that loose nuts were found on the West side of the Snubber pipe clamp. NCR 90-208 was initiated for Engineering review 80 disposition. Repairs were initiated to tighten the loose nuts. Reexamination of the snubber indicated the component was acceptable.

il

~ (

g'r

- ASME

~S Class: Snubber Program Appendix B stem: Standby Auxiliary Peedwater from Penetration Steam Generator Feedwater Header.

Line: 3C-PW-900-1B 123 to B Inspection revealed that the 2 1/16" observed setting did not compare with the 3 1/2" documented cold setting in ME-256 Specification. NCR 90-109 was generated to resolve this problem. Engineering revealed that the Gilbert scales show the proper setting to be 2 1/2". Engineering disposition of use-as-is was made along with a proposed revision to ME-256 Specification.

26. ASME Class: Snubber Program Appendix B

~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: SAP-RC-602 Code Re 'ectable Indication:

The Snubber hits the base plate at the wall and is missing its I.D. Tag. NCR 90-184 was generated. Engineering evaluation indicated a use-as-is disposition. The base plate does not impair the snubber function. A new I.D. Tag was installed. The reexamination of the snubber was acceptable.

27 'SME Class: Snubber Program Appendix B

~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 The Inspection revealed that, the snubber was missing an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.

28. ASME Class: Snubber Program Appendix B

~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6BP-RC-602 The Inspection indicated that the snubber was missing an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.

ASME Class: Snubber Program Appendix B

~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 Com onent: Hydraulic Snubber, N607 The Inspection indicated that the snubber was missing an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.

(17)

F

~a f- ~

30. ASME Class: Snubber Program Appendix B

~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 The Snubber hits the base plate at the wall and is missing its I.D. Tag. NCR 90-184 was generated. Engineering evaluation indicated a use-as-is disposition. The base plate does not impair the snubber function. A new I.D. Tag was installed. The Reexamination of the snubber was acceptable.

31. ASME Class: Snubber Program Appendix B l ~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6BP-RC-602 The Inspection indicated that the snubber was missing an I.D. Tag. NCR 90-184 was generated. A new I.D. Tag was installed. The reexamination was acceptable.
32. ASME Class: Snubber Program Appendix B

~S stem: Pressurizer Relief from Pressurizer to Relief Manifold Line: 6AP-RC-602 The'nspection indicated that the snubber was missing an I.D. Tag and a cotter key was broken at top of the component near the wall. NCR 90-184 was generated. Engineering disposition indicated that the cotter key should be repaired and a new I.D. Tag installed. The reexamination was acceptable.

33 'SME Class: Snubber Program Appendix B

~S stem: Power Pressurizer Relief Line Line: 3BP-RC-2501 Inspection indicated that the cotter key at top of the component was not engaged 100X and was deformed. NCR 90-112 was generated. Engineering review indicated a repair should be made. The reexamination was acceptable.

34, ASME Class: Snubber Program Appendix B

~S stem: Power Pressurizer Relief Line Line: 3BP-RC-2501 Code Re 'ectable Indication:

The Inspection revealed that the snubber had a broken cotter key and the clamp end bolting had lack of thread engagement. NCR 90-112 was generated for Engineering review.

An Engineering design analysis was performed to address the lack of thread engagement. The dispositioned of use-as-is was made by Engineering. Work was initiated on the support wi'th the cotter key being replaced. Reexamination of the component was acceptable.

(18)

KI 0

35. ASME Class: 3

~S stem: Auxiliary. Feedwater System Line: 2A-FW-900-1 This 4" Crane Check Valve had cracks on the gasket surface and valve body. NCR 90-096- was generated for Engineering review. The disposition was made to remove the indications and perform a weld repair under WO ¹ 9021452.

Reexamination was performed and acceptable. The NDE reexamination record was documented under the Maintenance NDE Summary Number 900023.

36. ASME Class: 2

~S stem: Low Pressure Safety Injection Line Line: 10-SI-151 Two linear indications, 1/8" 86 1/2" was identified in the 2" Weld-0-Let to Pipe Weld. NCR 90-102 was generated.

Engineering reviewed this condition and recommended a repair be performed by metal removal process under WO¹ 9021568. A reexamination was performed of the repaired area and was acceptable.

37. ASME Class: 2

~S stem: Steam Generator Blowdown Line: 2E-MS-600-IA The wall thickness was 68K T Nominal that equates to a minimum reading of 0.150". In 1988 &, 1989 the thickness of this section was 0.170". NCR 90-150 was generated for Engineering review &. disposition. An interim use disposition was made to repair the area by grinding and rewelding. Work was performed under WO¹ 9021695. Replacement of this

.component is scheduled for the 1991 Outage under EWR 4324C or reinspected in 1991 if the EWR is deferred.

38. ASME Class: 2

~S stem: Steam Generator Blowdown Line: 2E-MS-600-1A The wall thickness was 64X T Nominal that equates to a minimum reading of 0.140". In 1988 the thickness of this section was 0 '80" and in 1989 the thickness'was 0.160". NCR 90-150 was generated for Engineering review &, disposition. An interim use disposition was made to repair the area by grinding and rewelding. Work was performed under WO¹ 9021695.

Replacement of this component is scheduled for the 1991 Outage under EWR 4324C or reinspected in 1991 if the EWR is deferred.

(

'I

~4i

+V" I 1"

39. ASME Class: 2

~S stem: Steam Generator Blowdown Line: SB-'MS-600-1A During a Maintenance activity to remove Valve 3411 internals, seat.

it was discovered that scoring occurred Steam cuts was also observed on the face of on the the valve bonnet. NCR 90-234 was generated to address the problem.

Repairs were performed under WO¹ 9000043. Upon completion of welding 86 subsequent machining operations, reexamination of the component was acceptable.

40. ASME Class: Class 3

~S stem: Service Cooling Water Line: 2B-SW-152 Inspection indicated that a 3/32" wide by 1/8" long through wall indication was identified in the 2" pipe by support SWU-570. The through wall indication was caused by work activities associated with EWR 2512. NCR G90-022 was generated for resolution. Engineering review indicated that a weld repair be performed. A Code weld repair and subsequent examinations were performed by Projects under SM 2512.129. The NDE consisted of surface examinations, UT thickness measurements and Hydrostatic testing. All repair cycle examinations and testing were acceptable.

Appendix B of the Ginna Station Quality Assurance Manual identifies the component jurisdiction and requirements for the Replacement Program. The term Replacement includes both Replacements and Modifications.

Replacements and/or Modifications that were initiated prior to 1 January 1990 and installed during the 1990 Outage are under the jurisdiction of the Second Interval Appendix B Program requirements. Any Replacements and/or Modifications that were initiated after 1 January 1990 are under the Third Interval Appendix B Program requirements. During the 1990 Outage, no Major Modifications were initiated and/or installed to the Third Interval Program requirements.

The following Replacements and Minor Modifications were performed during the 1990 Outage and conforms to the Third Interval Program requirements.

1. ASME Class: 3

~S stem: Chemical & Volume Control Line: 2C-CH6-151 (20)

t Re lacement ~Summer : The ITT Grinnell Valve Bonnet was an approved equilivant replacement. Code required reconciliation and verification was performed and is documented under TSR 90-

25. This bonnet was ordered under PO NEG-87329 and was installed under Work Order 4 9000185. A VT-2 Leakage examination was performed and acceptable.

2 ~ ASME Class: 3

~S stem: Auxiliary Eeedwater Line: 3A-FW-900-1A Re lacement ~Summer : The Crane Valve Disk assembly was a "like and kind" replacement. The Code required verification was performed. The Crane seating and disc assembly was ordered under PO NQ 10274CSD, serial number 159953102 and installed under Work Order g 9021448. A VT-2 Leakage examination was performed and acceptable.

EROSIO CORR SION ~NW~LL ~POGRAN:

A Total of 312 Components were examined during the 1990 Outage. The breakdoun of this total number is as follows: 154 components were of pipes, 108 components were of elbows, 28 components were of Tees'-, 19 components were of reducers and 3 components were nozzles.

Component Thickness measurements were performed .on the following systems:

A/B Feedwater Pump Discharge to 5 A/B Heater.

Feedwater Cleanup to Condenser East Wall.

Heaters 4 A/B to Feedwater Suction.

Condensate Pump &, Heater Drain Tank Discharge to Fee dwater Suction.

Low Pressure Downcomers. s Low Pressure Downcomers in West Condenser.

Low Pressure Downcomers in East Condenser.

MSR lA, 1B 2nd Pass Drain.

MSR 2A, 2B 2nd Pass Drain.

MSR lA, 1B 2nd Pass Drain to 5A H.P.H. & Condenser.

MSR 2A, 2B 2nd Pass Drain to 5B H.P.H. & Condenser.

MSR,1A 4th Pass to 5A Heater.

MSR 1B 4th Pass to 5B Heater.

MSR 1A &. 1B 4th Pass to Condenser.

MSR 2A 4th Pass to 5A Heater.

MSR 2B 4th Pass to 5B Heater.

MSR 2A & 2B 4th Pass to Condenser.

1A, 2A &. 3A L.P.H. Drains to Condenser.

Steam Extraction to Preseparator B & 4B L.P.H.

Steam Extraction to Preseparator A & 4A L.P.H.

Condensate Booster Pumps to Hydrogen Coolers.

MSR 1A & 1B to Heater Drain Tank.

MSR 2A & 2B to Heater Drain Tank.

5A H.P.H. Drain to 4A L.P.H.

5B H.P.H. Drain to 4B L.P.H.

Preseparator A/B to Heater Drain Tank 8c Condenser.

Preseparator A/B to Heater Drain Tank.

Turbine Driven Auxiliary Feedwater Pump to Discharge Lines.

Auxiliary Feedwater Pump A to Discharge Lines.

Auxiliary Feedwater Pump B to Discharge Lines.

Steam Extraction to 5A R 5B H.P.H.

Feedwater Discharge, Turbine Building.

Steam Generator Blowdown Lines, (Intermediate Building)

Steam Generator Blowdown Lines, (Turbine Building)

Steam Generator 1A Blowdoun Lines, (Containment Building)

Steam Generator 1B Blowdoun Lines, (Containment Building)

Feedw'ater Recirculation (CV-18).

Feedwater Recirculation (CV-19).

Main Feedwater Pump Bypass.

Steam Generator Blowdoun to Condenser.

Service Mater in Screen House.

Heater Drain Tank to Condenser, Main Steam Dump to Condenser.

Blowdown Tank to Condenser.

Blowdown Tank to 3A Low Pressure Heater.

Gland Steam Discharge to Gland Steam Condenser.

Preseparator Drain to Preseparator Vent.

4B Low Pressure Heater Vent.

Prepared By: 7-]3 PO Frank A. Klepacki ISI Engineer I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspections and employed by The Hartford Steam Boiler Inspection and Insurance Company have inspected and/or verified that the components described within this report and associated Attachments during the stated reporting time frame, and state to the best of my knowledge and belief, the Owner has performed examinations and corrective measures described in this Report.. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Reviewed By: 7 js 5"o ANII's Signature Date Approved By:

Michael J. Sa ori.to Supervisor, Materi.'als Engineering NDE Level III (22)

t' ef D,

GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990 1999 Interval, First Outage 1990 Attachment I gU1~A4+

A. CLASS 1 COMPONENTS:

e Summary NDE Number Com onent Exam Results 004400 Surge Line Nozzle PT PT h. UT, no recordable to Reducer Weld; UT indications. Limitations SLNSEW due to ID Plate -acceptable.

005000 Safety Nozzle ¹1 PT PT 8r. UT, no recordable to Safe End; UT indications acceptable.

RC-273-I 005200 Safety Nozzle ¹2 PT PT & UT, no recordable to Safe End;- UT indications. Limitations, RC-273-S 1" downstream due to reducer acceptable.

005600 Manway Bolting, VT-1 VT-1 8c UT, no recordable 16 total. UT indications. MT required MT only when removed-bolting not removed. Acceptable.

2 Summary

~ ~gg &'l NDE h=~ a=a Exam Results 006000 Elbow to Safe End PT PT Ec UT, no recordable Inlet Nozzle Weld; UT indications, unable to skew PL-FW-I-ASW 45 degrees due to curved shoe acceptable.

006200 Outlet Nozzle Safe PT PT 8c UT, no recordable End to Elbow Weld; UT indications, unable to skew PL-FW-IX-ASW 45 degrees due to curved shoe.

No upstream exam due to nozzle

-acceptable.

006430 Inlet Manway Nuts; VT-1 VT-1, MT 8c UT, no recordable 16 Total. UT indications acceptable.

MT

C Summary NDE Exam Results 006435 Inlet Manway Studs; VT-1 VT-1, MT 8c UT, no recordable 16 Total. UT ,indications acceptable.

MT Summary NDE Exam Results 009200 Component Support VT-3 VT-3, no recordable indications Hanger; RHE-8-PR1 acceptable.

~tt 4 R '

ll 'B Summary NDE Exam Results 014000 Safe End to Pipe UT PT; no recordable indications.

Weld' PT UT; no recordable indications, UT,Geom: 2 indications upstream acceptable.

Pipe to Pipe Weld; PT; no recordable indications.

a.

014100 UT B PT UT; no recordable indications, UT, Geom: 2 indications, 1 upstream &. 1 downstream-acceptable..

014200 Pipe to Pipe Weld; UT PT; no recordable indications.

C PT UT; no recordable indications, UT, Geom: 2 indications, 1 upstream &, 1 downstream acceptable.

r w 014500 Pipe to Nozzle UT PT 8c UT; no recordable Weld; D .PT indications. UT Geom upstream acceptable.

5 2tt Summary NDE Exam Results 023000 Tee to Pipe Weld; PT PT; no recordable indications 9 acceptable.

Qi

,f I

Summary NDE Exam Results 025200 Pipe to Elbow Weld; PT PT; no recordable indications 20 acceptable.

026000 Pipe to Reducer PT PT; no recordable indications Weld; 27 RT (to verify removal of surface type Geom, indication.) RT; no recordable indications, Insig.,

intermittent IUC, suck-up, tungsten spot Bc spot pores acceptable.

~i~ 10 - I2- 5 Summary NDE Exam Results 034200 Elbow to Pipe UT PT 8c UT; no recordable Weld; GSW-2 PT indications. UT Geom:

upstream inside surface acceptable.

~L'e: 0 -S -2501-B Summary NDE Exam Results 034530 Hydraulic Snubber VT-3 VT-3; no recordable Support; SIU-3 indications, PSA-10 setting of 3 1/4" at a temperature of 57 deg. F. acceptable.

036100 Elbow to Nozzle UT PT; Insig: 1/4" long arc strike Weld; K PT -acceptable per Section XI table 3514-2. UT; no recordable indications acceptable.

7, 9" ~ow L>~~~@ Ryi~~

0 Summary NDE Exam Results

/

036400 Rigid Hanger, PT PT; Rej,, slag inclusions at Integral Attachment; NE & SE Lug plates in crotch RHU-22 area. NCR 90-163 generated, use-as-is per Engineering evaluation-acceptable.

,gS Summary NDE Exam Results 036500 Rigid Hanger VT-3; no recordable Support; RHU-22 indications acceptable.

8e 4" ~w ~8~4~~ ~Sa e ~stem:

Summary NDE Exam Results 036800 Elbow to Pipe UT PT 8r, UT; no recordable Weld; H PT indications acceptable.

9. $ " ~w ~~~ ~~ ~~tg

'ummary NDE Exam Results 037600 852A Valve to Pipe UT PT R UT; no recordable Weld; J PT indications. UT; Geom., Elbow side, root geometry acceptable.

10.  !

&'ummary NDE Exam Results 039600 Pipe to Elbow PT PT, Rej.; Rough weld &, pores in Weld; ASW-1 center line of weld. Reexam.

after blending weld- no recordable indications per Sect. XI IWB-3514- 2,

-acceptable.

11 2" ROXeM l e.

LKULSall Summary NDE Exam Results 041600 Pipe to Elbow PT Insig ~ ; 1/16" Dia. round Weld; GSW-14 indication. Acceptable per Section XI IWB-3514-2.

c)>

l l.

Summary NDE Exam Results 042300 Nozzle 'to Pipe PT PT: no recordable indications Weld; 1 acceptable.

D w h='UUI Summary NDE Exam Results 043300 Pipe to Elbow PT PT: no recordable indications Weld; 6 acceptable.

Summary NDE Number Com onent Exam Results 046000 Rigid Restraint PT PT: no recordable indications Integral Attachment acceptable.

Support; CVU-31 046020 Rigid Restraint VT-3 VT-3: no recordable indications Support; CVU-31 acceptable.

al~akJ~

Summary - NDE Exam Results 051200 Elbow to Pipe PT PT: no recordable indications Weld'7 acceptable.

I" Alt Summary NDE Exam Results 052525 Anchor Integral PT PT: no recordable indications Attachment Support; acceptable.

CVU-24

C")

Summary NDE Exam Results 052530 Anchor Support: VT-3 VT-3; no recordable indications CVU-24 acceptable.

053300 383A Valve to Pipe UT PT Sc UT; no recordable Weld'8 PT indications acceptable.

053800 Pipe to Nozzle PT PT; no recordable indications Weld; 43 acceptable.

w Summary NDE Exam Results 054200 Variable Spring VT-3 VT-3; Rej. 3/4" rod bent. NCR Support; CVU-51 90-167 generated. Reexam.

after repairs, Setting of 61¹ at 65 deg. F.,Support SN: 582

-acceptable. Service Induced expanded scope required. See Summary ¹'s 054300 5, 054900.

054300 U-Bolt Support; VT-3 VT-3; no recordable indications CVU<<50 acceptable, no degradation of component identified with expanded service induced scope.

054300 Variable Spring VT-3 VT-3; no recordable indications Support; CVU-5 acceptable, no degradation of component identified with expanded service induced scope.

Setting of 135¹ at 63 deg. F.

Berger Patterson Size 3 support.

055100 393 Valve to Pipe UT PT & UT; no recordable Weld; 11 PT indications - acceptable.

lt I

l S P l

0

15. ~Rabat)~ ~Cl~at ~P

~u ~C~~ ~We ~ aw Summary NDE Exam Results 057410 Weld A VT-1 VT-1 8c PT; no recordable PT indications. VT-1, Insig; pits from casting process 360 deg.

around weld < 1/32". Grind marks from prepping-acceptable.

PT, Insig; 15 Random rounded indications < 1/16" Dia., small scale 1/8 x 1/4 and 4 gouges at weld attachments < 1/32" acceptable.

057420 Weld B VT-1 VT-1 &. PT; no recordable PT indications. VT-1, Insig; pits from casting process 360 deg.

around weld < 1/32". Grind marks from prepping-acceptable.

PT; Insig., casting rounded inclusions 1/8" Dia.;

Limitations due to pump supports B-1, B-2 &, B-3 over weld for 20" each acceptable.

057430 Weld C VT-1 VT-1 & PT; no recordable PT indications. VT-1 & PT; Insig.,

Gouge 1/2 x 1/32 deep by 1/16 wide at 11 1/2" location acceptable. Also, 1/2" Dia.

rounded indication above gouge with cluster porosity < 1/64" each -acceptable.

w Summary NDE h Exam Results 057910 Support 1 ,VT-1 VT-1 &, PT; no recordable PT indications. VT-1, Insig.;

minor pits < 1/32" in casting, grind marks from welds ground flush -acceptable. PT, Insig.;

2 indications each 3/8" long.

Indications are underbead cold laps at edge of weld and are not service induced acceptable.

4e

$g

Summary NDE Exam Results 057920 Support 2 VT-1 VT-1 8c PT; no recordable PT indications. VT;1, Insig.;

under cut < 1/32" long acceptable. PT, Insig.; Linear indication 7/16" long is undercut < 1/32" deep, Indication not service induced and acceptable per Section III NB4424(C).

057930 Support 3 VT-1 VT-1 8c PT; no recordable PT indications. VT-1, Insig.;

Weld is prepped showing grind marks < 1/32" deep acceptable.

16. Qeac~o ee Coa,'~Q ~ ~e: W Summary NDE Exam Results 058200 Flywheel, SN: UT UT; no recordable indications, 212-3D19156-G01-02 Top side keyway bore reflections were observed acceptable.
17. Va.'I vi~

~0 ~~q VVVv~e w Summary NDE Exam Results 058300 Darling Check VT-1 VT-1; no recordable indications Valve 842A acceptable.

10" ~Ce<+ V~alv Summary NDE Exam Results 058400 Darling Check VT-1 VT-1; no recordable indications Valve 842B acceptable.

4 Summary NDE Exam Results 059100 Velan Motor Oper. VT-1 VT-1; no recordable indications Gate Valve 701 bolts inspected in place acceptable.

~G ~V~v ~5)0 ~bs Summary NDE Exam Results 059200 Velan Motor Oper. UT PT & UT: no recordable Gate Valve; 720-1 PT indications acceptable.

Body Weld 059205 Velan Motor Oper. UT PT &, UT: no recordable Gate Valve; 720-2 PT indications acceptable.

Body Weld 059210 ,Velan Motor Oper. VT-3 VT-3; no recordable indications Gate Valve; 720 acceptable.

059300 Velan Motor Oper. VT-1 VT-1, MT &. UT: no recordable Gate Valve; 720 indications. Baseline exam performed in 1989. Nuts and Studs installed in 1990.

6" ~Ceca ~Vive Summary NDE Exam Results 059600 Velan Check Valve; VT-1 VT-1: no recordable indications, Bolts inspected in place acceptable.

Summary NDE Number Com onent Exam Results 059600 Velan Check Valve; VT-1 VT-1: no recordable indications, Bolts inspected in place acceptable.

V t

1t>

I g 'I

joe~ ~Vvea Summary NDE Exam Results 060000 Crosby Relief VT-1 VT-1: no recordable Valve; 434 indications on 8 1 1/4" Dia.

Bolts, 93 1"x8 nuts &, 48 1"x8x7" studs. Rej: 12 1" Dia.

Bolts. NCR 90-159 was generated for disposition.

Examination performed after installation; flange, bonnet studs & replacements acceptable.

060100 Crosby Relief VT-1 VT-1: no recordable Valve; 435 indications, 93 1"x8 nuts & 48 1"x8x7" studs. Insig: 1 of 1 1/4" Dia. bolts have minor corrosion; 7 bolts, NRI with 8 acceptable. Re): 12 1" Dia.

bolts with thread damage. NCR 90-159 was generated for disposition. Examination performed after installation; flange, bonnet studs &,

replacements -acceptable.

CoK~tQ; ~Eely Summary NDE Exam Results 060200 Copes-Vulcan VT-1 VT-1: no recordable Control Valve; indications acceptable.

430 3" ~ Zalea W H

Summary NDE Exam Results 060600 Velan Motor Oper. VT-1 VT-1; no recordable indications Gate Valve; 515 acceptable.

(l wh, I

~i~t+o. ~Va ve Summary NDE Exam Results 060200 Copes-Vulcan VT-1 VT-1: Rej: heavy corrosion Control Valve; on nuts, WO 9021545 was 200A generated to clean nuts for examination in accordance with A-1407 Procedure. No recordable indications &, no material degradation observed acceptable.

060900 Copes-Vulcan VT-1 VT-1: no recordable Control Valve; indications - acceptable.

200B 070000 Copes-Vulcan VT-1 VT-1: Rej: Boron deposits Control Valve; on top of gl &. g7 nuts and, 202 between nuts &, bolts. WO 9021545 was generated to clean deposit areas for examination in accordance with A-1407 Procedure. No recordable indications & no material degradation observed acceptable.

B. CLASS 2 COMPONENTS:

1. o

'La Summary NDE Exam Results 072240 7/8" Diameter UT VT-1: no recordable Bolts VT-1 indications. Insig: slight MT rust on all bolting. All studs were double nutted top &

bottom. One stud over V204A had 1 nut on bottom due to lack of space -acceptable. MT:

required when bolts are removed, bolting not removed.

UT: no recordable indications, 20 bolts were examined from top

& bottom -acceptable.

i<

l

%b

Summary NDE Exam Results 073170 Support Leg ¹3; VT-3 VT-3: no recordable S3 indications. Insig: paint on weld acceptable.

073400 Support Leg ¹3; PT PT: no recordable indications.

Integral Attachment Insig: Weld spatter on weld,

'eld, S3 nonrelevant indication acceptable.

3. Pg~~o ~o~ ~Flter:

~Wl~e Summary NDE Exam Results 073170 Support Leg ¹3; PT PT: no recordable indications Integral Attachment acceptable.

Weld, L3 074760 Support Leg ¹3; VT-3 VT-3: no recordable L3 indications acceptable.

I IL

-2 2 Summary NDE Exam Results 075800 Pipe to Elbow UT PT 83 UT; no recordable Weld; 2 PT indications acceptable.

5. ~Se

~We ~gc~cC IL Summary NDE Exam Results 078630 Support Leg ¹2; VT-3 VT-3; no recordable Welded Support, 2 indications. Insig; 4 pinholes 1/64", light undercut < 1/16" and peening marks acceptable.

i F')

,I

Summary NDE Exam Results 074760 Support Leg 42; PT PT: no recordable indications.

Integral Attachment Insig; 3 scattered pin holes Weld, 2 1/32" Dia. acceptable.

6. ~ St~@ ~oo Summary NDE Exam Results 080400 Anchor Support in VT-3 VT-3; Rej, Lack of thread Pen. 401 Outside MT engagement. NCR 90-186 was Containment; PS-A generated. Engineering disposition of use-as-is was made. MT; Insig, 3/4"xl"x1/2" circular indication with scabs from fabrication acceptable.

080450 Anchor Support in VT-3 VT-3; no recordable indication Pen. 401 Inside MT Insig; intermittent arc strikes Containment; PS-B 360 deg. < 1/32" -acceptable.

MT; no recordable indications, made. MT; Insig, 3/4"x1"xl/2" 080600 Pipe to Elbow RT VT-1, MT 8c RT; Examined as High Weld; D MT Energy Weld, see Summary No.

VT-1 200005 for 1990 results.

083200 6" Branch Conn. RT VT-1; no recordable indication Weld'3-BC-3 VT-1 Insig: various arc strikes, MT intermittent undercut &, light rust acceptable. MT; Insig, areas of arc strikes acceptable. RT; Other, weld configuration not conducive for RT examination.

083300 6" Branch Conn. RT VT-1; no recordable indication Weld; G3-BC-4 VT-1 Insig: various arc strikes, MT intermittent undercut acceptable. MT; no recordable indications in areas of arc strikes -acceptable. RT; Other, weld configuration not conducive for RT examination.

1" P tl cled~

y 8

Summary NDE Exam Results 083860 Bolting (< 2") VT-1 VT-1; no recordable G2-BC-2-B-BT MT indications on 12, 1"x7 1/4" UT studs acceptable. MT; MT not performed, only when studs are removed. UT; no recordable indications, scanned from top side only -acceptable.

S ILJIQS Summary NDE Exam Results 086800 Mechanical Snubber VT-3 VT-3; no recordable indications Support, MSU-15 SN 7476, North setting = 3" South 3 1/4" at a Temp. of 53 deg. F, -acceptable. Insig; snubber can not be rotated by hand -acceptable.

086805 Mechanical Snubber MT MT: Insig; intermittent EUC on Integral Attachment both North South snubber that 8r.

Weld, MSU-15 is < 1/32" 360 deg. around pipe side -acceptable.

087600 Guide Support; VT-3 VT-3: no recordable indications MSU-24 acceptable.

088100 Variable Spring VT-3 VT-3; no recordable indications Support; MSU-28 acceptable. Insig; rivet missing on ID Tag. Setting of 3 1/4 with load of 108524 at 47 deg. F., Berger patterson VS-1 support-acceptable.

Summary NDE Exam Results

'89300 6" Branch Conn. RT VT-1; no recordable indication Weld; L2-BC-1 VT-1 Insig: Light rust 360 deg. on MT weld, intermittent weld spatter Sc undercut < 1/32" deep acceptable. MT; no recordable indications -acceptable. RT; Other, weld configuration not conducive for RT examinations

l l 'A

Summary NDE Exam Results 093500 Variable Spring VT-3; Rej. Top nut, not in full Support; FWU-1 thread engagement. NCR 90-173 was generated for Engineering evaluation. Condition previous addressed on NCR G83-132, use-as-is -acceptable.

093505 Variable Spring MT MT; no recordable indications Integral Attachment accept'able.

Weld, FWU-1 094300 Elbow to Nozzle RT VT-1 &, MT; no recordable Weld; EE MT indications acceptable.

VT-1 RT; Insig, Various porosity, no apparent change since last examination on 4/7/89.

aw Summary NDE Exam Results 095400 Mechanical Snubber VT-3 VT-3; no recordable Support, FWU-47 Boot covering snubber indications'ubber is ripped. Acceptable for ISI examination, Trouble Card written for boot covering.

096800 Rigid Restraint VT-3 VT-3: no recordable indications Support; FWU-56 acceptable.

097200 Pipe to Elbow RT VT-1 &, MT; Weld prep for I-98 Weld'2 MT UT, no recordable indications.

VT-1 PT;(Aug. exam) no recordable UT indications. UTTK;(Aug. exam)

PT acceptable. UT; (I-98), no UTTK Recordable indications. UT; (I-98), Geom; ID configuration. UT performed in lieu of RT.

Summary NDE Exam Results 099900 Elbow to Nozzle RT VT-1 8c MT; no recordable Weld; BB MT indications acceptable.

VT-1 RT; Insig, Various porosity>

UT slag &, suck up. No apparent change since last examination on 3/27/89. UT; no downstream examination, indications were inclusions &, ID surface geometry acceptable.

9. ~ow +~si~ c~e~t I " ~

Summary NDE Exam Results 100310 2" Branch Weld; PT PT; no recordable indications 5M acceptable.

100325 Guide Support; VT-3 VT-3: no recordable indications SIU-109 acceptable. White powder residue from installation.

100925 Guide Support; VT-3: Insig, insulation residue SIU-108 resulting in light corrosion acceptable. Rej; Loose micarta block identified. NCR 90-160 was generated. Engineering evaluation provided use-as-is status.

I E I'

Summary NDE Exam Results 106050 Rigid Support; VT-3 VT-3: no recordable indications SIU-103 acceptable.

(

Summary NDE Exam Results 110300 Variable Spring VT-3 VT-3; no recordable indications Support; RHU-78 acceptable. Setting of 7/8" equates to a load of 644 4's at 61 deg. F..

e ~Stem:

iLJ Summary NDE Exam Results 110900 Pipe to Elbow PT PT 80 UT; no recordable Weld; 1A UT indications acceptable.

~ Resi~dg, ~a Qe@~v, ~S~t~n~

II raw'3

'LJR Summary NDE Exam Results 126400 Pipe to Tee PT PT 80 UT; no recordable Weld; 6 UT indications acceptable.

14. ~R~~~

P geea. Eeeoval, ~i~erg:

IJ Summary NDE Exam Results 129900 Tee to Pipe PT PT 80 UT; no recordable Weld; 1 UT indications - acceptable.

~+

I to

15. ~Resid a Heat ~Remove

~Sstem'-20 Summary NDE Exam Results 130300 Pipe to Pipe PT PT; Rej; initial exam indicated Weld; 1 UT linear indications. PT; reexam indicated that the linear marks were created by mechanical means, use-as-is by Materials Engineering - acceptable. UT; no recordable indications acceptable.

130550 2" Branch Weld; PT PT; no recordable indications 3A acceptable.

16. ~Raid al Heat ~emova ~Sst m:

Summary NDE Exam Results 133100 Elbow to PT PT 85 UT; no recordable 24 Flange'Weld; UT indications acceptable.

17. ~Res d al ~t removal ~Sstem:

ILRII Summary NDE Exam Results 133900 Rigid Restraint VT-3 VT-3: no recordable indications Support; RHU-28 acceptable.

133910 Rigid Restraint PT PT: no recordable indications Integral Attachment paint removed acceptable.

RHU-28 Summary NDE Exam Results 136000 Elbow to Tee PT PT &, UT; no recordable Weld; 17 UT indications acceptable.

-1 yl

18. iiesidu~ iiSS2 ~eoval ~St~m:

ILs Summary NDE Exam Results 140000 Rigid Hanger; VT-3 VT-3: no recordable indications RHU-383 acceptable,

19. ~Res'd a ~a gem<~vit. ~Ss~tnu C- C-60 raw' iLm Summary NDE Exam Results 144150 2" Branch Weld; PT PT; no recordable indications 19A Limitations; Hanger clamp 1/4" from toe of weld acceptable.
20. Lest~a ~Hea ~Re i~vs . ~Ss em'ummary NDE Exam Results 154250 Rigid Hanger VT-3 VT-3: no recordable indications Support; RHU-58 acceptable.

154255 Rigid Hanger PT PT: no recordable indications Integral Attachment paint removed acceptable.

RHU-58 154700 Elbow to Pipe FT PT &, UT; no recordable Weld; 1M UT indications acceptable.

21. ~es < iUt1 ~He t ~Remov ~Si~SL su Summary hfDE Exam Results 158500 Nozzle to Elbow PT PT L UT; no recordable Weld; 1 UT indications acceptable.

Pp

~Lin 10- D aw'ummary NDE Exam Results 159100 Rigid Support VT-3 VT-3:no recordable indications.

RHU-101 Insig. Spot of weld at 0" 8L 4" on 10" Elbow, weld deposit-no linear indications -acceptable.

No ID Tag. Additional Exam after NCR 90-091 for RHU-129 Service Induced Degradation.

No Service Induced Degradation found with expanded exam scope.

159105 Rigid Support VT-3 VT-3:no recordable indications.

Integral Attachment Insig, Spot of weld at 0" &, 4" Weld, RHU-101 on 10" Elbow, weld deposit-no linear indications -acceptable, No ID Tag. Additional Exam after NCR 90-091 for RHU-129 Service Induced Degradation, No Service Induced Degradation found with expanded exam scope.

159450 2" Branch Weld, PT PT: no recordable indications A4A acceptable,

23. ~o +~~re ~a~et I 8 hixn' Summary NDE Exam Results 159900 Variable Spring VT-3 VT-'3: Service Induced Reject; Support, RHU-129 Rod in spring can is l'ocked.

Space in front of can is 1/2",

Rod touches rear of can. NCR 90-091 was generated for Engineering disposition.

Repairs performed with reexamination acceptable -no recordable indications.

Setting of 6614 at a Temp. of 69 deg. F. for size 7 acceptable. See Summary No.'-s 159100 & 160400 for expanded scope results.

159901 Variable Spring PT PT: no recordable indications.

Integral Attachment acceptable.

Weld, RHU-129 1

Jg lg

24. ~Lw ~re sure ~Sa et Summary NDE Exam Results 160400 Variable Spring VT-3 VT-3: no recordable indications Support, RHU-130 -additional exam after NCR 90-091 for RHU-129 Service Induced Reject. No Service Induced Degradation found. Setting of 482¹ at 69 deg. F. -acceptable.

-S -3 Summary NDE Exam Results 160550 -

Rigid Support VT-3 VT-3: Reject-Support to elbow RHU-126 not welded all around. Missing 3" to 3 1/2" of weld on upper outmost radius. NCR 90-164 was generated. Engineering disposition and evaluation indicated that the existing weld is adequate and should be used as is acceptable.

Ih! t! e Summary NDE Exam Results 161350 Rigid Restraint VT-3 VT-3: no recordable indications Support, -SIU-73 Insig, grease fitting painted over, Restraint will not swivel back and forth -acceptable.

161390 Variable Spring VT-3 VT-3: no recordable indications Support, SIU-72 settings were taken at a "Temp. of 77 deg. F. of 5/8" equating to 250¹ -acceptable.

161391 Variable Spring PT PT: no recordable indications Integral Attachment paint removed from weld Weld, SIU-72 acceptable.

A$

Jgl F"'

~Li e: A-S 0 Summary NDE Exam Results 162090 Tee to 3/4" PT PT: no recordable indications Reducer Weld, 28 acceptable.

162210 Rigid Restraint VT-3 VT-3: no recordable indications Support, SIU-29 acceptable.

idee: -SI- 5 Summary NDE Exam Results 162740 Pipe to Elbow PT PT R UT; no recordable Weld'6 UT indications acceptable.

fe ~e Summary NDE Exam Results 163110 Pipe to Tee PT PT 8c UT; no recordable Weld; 10 UT indications acceptable.

ee p ee.f aJ e r wi Summary NDE exam Results 163590 Spring Can VT-3 VT-3: no recordable indications Support, SIU-68 setting of .7" or 5490 at a Temp, of 78 deg, F.-acceptable.

163591 Spring Can PT PT: no recordable indications Integral Attachment paint removed- acceptable.

Weld, SIU-68 I

Summary NDE Exam "

Results 163640 Rigid Restraint VT-3 VT-3: Reject. Ear on pipe clamp Support, SIU-66 is bent inward. NCR 90-247 was generated for Engineering review. Clamp was replaced, reexamined-acceptable.

Additional Exam performed after NCR 90-107 for SIU-58 that was a Service Induced Reject. No Service Induced Degradation was found with expanded scope acceptable.

163650 Guide Support VT-3 VT-3: no recordable indications SIU-65 acceptable.

163690 Rigid Support VT-3 VT-3: no recordable indications SIU-63 acceptable.

163710 Elbow to Pipe PT PT &, UT; no recordable Weld; 16 UT indications - acceptable.

UT, Insig; Geometry downstream acceptable.

163790 Rigid Restraint VT-3 VT-3: Reject. Identified Support, SIU-59 bushing in upper clamp section while no bushing was in the lower clamp. NCR 90-090 was

- generated. Bushing is actually a spacer Ec only required on one bolt per QC. Use-as-is, acceptable. No other recordable indications acceptable. Additional exam performed after NCR 90-107 for SIU-58 Service Induced Reject.

No Degradation found with expanded scope -acceptable.

163820 Rigid Support VT-3 VT-3: Service Induced Reject, SIU-58 Loose nut identified on top while the nut on the bottom tube can be turned by hand.

NCR 90-107 was generated for disposition. Nuts were tightened, Reexam after repairs acceptable. For Service Induced Code Reject,'xam.

scope was expanded. Exams were performed on Summary 0's 163830, 163790 8c 163640.

p Summary NDE Exam. Results 163830 Rigid Restraint VT-3: Additional exam after Support, SIU-57 NCR 90-107 for SIU-58 for Service Induced Reject. No Service Induced Degradation was found -acceptable.

31 ~ HiiHh ~rsyure ~~et Summary NDE Exam Results 164300 Flange to Pipe PT PT &, UT; no recordable Weld; 56 UT indications acceptable.

iLk4 Summary NDE Exam Results 164700 Pipe to Valve 878H PT PT; no recordable indications Weld'9 acceptable.

33 'a'S~a ~t~

Summary NDE Exam Results 166050 Reducer to Pipe PT PT &, UT; no recordable Weld; 2 UT indications acceptable.

UT, Root Geometry

%l 6 -S -30 Summary NDE Exam Results 166840 Rigid Support VT-3 VT-3 Rej., 1 1/2" of weld CSU-33 UTTK missing at crotch & arc strike PT adjacent to the weld. NCR 90-089 was generated. Arc strike was blended out. UT thickness readings obtained &, Acceptable.

PT &, VT-3 reexam after repairs

-acceptable'ngineering evaluation performed on missing weld with a use-as-is determination based on design analysis EWR 2512 &, ME 39 Attachment Bl.

166842 Rigid Support PT PT; no recordable indications Integral Attachment acceptable.

CSU-33 C. CLASS 3 COMPONENTS:

Summary NDE Exam Results 500200 Rigid Support VT-3 VT-3: no recordable indications Integral Attachment acceptable.

CCU-86 500205 Rigid Support VT-3 VT-3: no recordable indications CCU-86 Insig; no grout not required per ME121. Weep hole accepted, general practice when welding a confined component -acceptable.

~h

2. Service Water:

Summary NDE Exam Results 502080 Rigid Support VT-3 ,VT-3: no recordable indications Integral Attachment Insig. surface rust 8c light SWU-212 scale on weld acceptable.

500205 Rigid Support VT-3 VT-3: Rej. 4 nuts 1/8" short of SWU-212 full thread engagement. NCR 90-090 was generated for Engineering review. The disposition indicated that the load was in compression and that the condition was use-as-is. acceptable.

D aw'ummary NDE Exam Results 502130 Variable Spring VT-3 VT-3: no recordable indications Integral Attachment Insig. light rust on weld SWU-120 acceptable.

502135 Variable Spring VT-3 VT-3: no recordable indications Support, SWU-120 at a Temp. of 57 deg. F. the setting was 299¹'s -acceptable.

MRLIR5=

Summary NDE

/umber Com onent Exam Results 503620 Rigid Restraint VT-3 VT-3: no recordable indications Integral Attachment Insig. Light rust on lugs, SWU-384 welds R pipe acceptable.

503625 Rigid Restraint VT-3 VT-3: no recordable indications Support, SWU-384 pipe clamp insulated acceptable.

t d

Summary NDE Exam Results 505000 Guide/Rigid Support VT-3 VT-3: no recordable indications Integral Attachment with paint removed -acceptable.

AFU-08 505005 Guide/Rigid Support VT-3 VT-3: Rej. Guide does not AFU-08 conform to the component support drawing. Pipe was replaced by steel block with no attachment weld to the pipe.

NCR 90-108 was generated for Engineering review.

Disposition indicated that no nonconformance occurred due to review of the revised drawing, Revision 1 -acceptable.

Summary NDE Exam Results 505270 Variable Spring VT-3: no recordable indications Support, AFU-104 'Support is a size 9 with a setting of 870 0's taken at a Temp. of 272 deg. F.. Support ID4 is N-EG-13312-82-330 acceptable.

eedwater:

Summary NDE Exam Results 507000 Variable Spring VT-3: no recordable indications Support, AFW-14 Support is a Navco type E, Model BE-401 size 0 that had a setting of 604's at a Temp. of 66 deg. F..

507090 Guide Support, VT-3: no recordable indications AFU-221 Other; New tag for AFU-221 was (was AFW-22) attached to the support & a new baseline was performed and accepted.

Nt

/

0

Summary NDE Exam Results 507180 Variable Spring VT-3 VT-3: Rej. Can setting reading Support, AFW-30 of 580¹'s conflicted with the 540¹'s that the Specification allows. NCR 90-185 was generated for Engineering review. The support was reset, reexamined and acceptable.

Summary NDE Exam Results 507380 Guide, VT-3 VT-3: no recordable indications integral Attachment Other, New tag for AFU-165 was AFU-165 attached to the support. A new (was AFW-88) baseline was performed and accepted.

507385 Guide, VT-3 VT-3: no recordable indications AFU-165 Other, New tag for AFU-165 was (was AFW-88) attached to the support. A new baseline was performed and accepted.

Summary NDE Exam Results 508000 Variable Spring VT-3 VT-3: no recordable indications Support, AFW-3 acceptable. This support is a Navco Type D Size 3 that had a setting of 190¹'s at a Temp.

of 64 deg. F..

508090 Hydraulic Snubber VT-3 VT-3: Rej. Cold setting should Support, AFU-208 be 3 1/2" was 2 1/8". NCR 90-(was AFW-13) 109 was generated for Engineering review. Disposition indicated that the Gilbert Scales show a 2 1/2" reading.

Engineering to revise ME-256 and use-as-is the support to its existing, setting.

'T,

~ lp

Summary NDE Exam Results 508860 Guide Support VT-3 VT-3: Rej. Bottom weld on East Integral Attachment side has lack of weld at toe.

SWU-500 NCR 90-188 was generated for (was SW-88) Engineering review. Disposit,ion indicated that repairs will be made. Reexam after repairs indicated insignificant results being that small pinholes 1/16" were found 8L acceptable.

This support, has been upgraded to SWU-500 508863 Guide Support VT-3 VT-3: Guide was formerly SW-88 SWU-500 and has been upgraded to SWU-(was SW-88) 500 Examination indicated no

~

recordable indications acceptable.

D. HIGH ENERGY COMPONENTS:

1. ~Min Steam ~Loo g ~Out ide Containment:

Summary NDE Exam Results 200005 Pipe to Elbow VT-1 VT-1 8L RT: no recordable Weld, D RT indications. VT-1: Insig.Gouges MT from line-up lug ( 1/32" deep, acceptable. MT: Insig, surface scabs acceptable. RT: Insig.

Fine 8C spot porosity, all porosity acceptable per table A-5 NACSI 3/2/82.'00120 Elbow to Pipe VT-1 VT-1 MT 8L RT: no recordable Weld, E2 RT indications. VT-1: Insig.

HT Intermittent undercut up 8L down stream. An arc strike was also identified and prepped to 1/32" -all acceptable. RT:

Insig. Suck-up, fine porosity, slight weld concavity &, minor U/C -all acceptable, tg V

~ ~

1

2. ~Ma'team ~Lao B Outside C ntainment:

a ~ s Summary NDE Exam Results 200030 Pipe to Elbow VT-1 VT-1,MT &, UT: no recordable Weld, D RT indications. VT-1:Insig. Light MT rust on pipe weld-acceptable.

8L UT UT performed in lieu of RT.

200175 Elbow to Pipe VT-1 VT-1 & MT: no recordable Weld, E RT indications for weld prep.

MT PT: no recordable indications.

UT UTTK: initial and final PT thickness measurements for the UTTK weld prep -acceptable. UT: no recordable indications. UT:

Geom, Thickness change, root geometry, counterbore and ID acceptable.,

200180 Elbow to Pipe VT-1 VT-1: no recordable indications Weld, J RT VT-1, Insig, Minor pits < 1/32"

,light rust and grind marks from weld prep-acceptable. UT, PT &, MT: no recordable indications-acceptable. UTTK:

initial and final thickness measurements for weld prep acceptable. UT: Geom, rough root acceptable. UT performed in lieu of RT.

I k

~ice: 1 HE:

Summary NDE Exam Results 200070 Pipe to Pipe VT-1 VT-1,MT &, UT: no recordable Weld, AA RT indications. VT-1:Insig. Under MT cut < 1/32" deep-acceptable.

UT UT: Geom. ID counterbore configuration was confirmed by RT. Root Geometry acceptable.

UT performed in lieu of RT.

I I

~h 1

Summary NDE Exam Results 200410 Pipe to Pipe VT-1 VT-1, PT R UT: no recordable Weld, V2 RT indications. VT-1:Insig. One MT pit, undercut was removed when UT weld was ground flush PT acceptable. MT; Insig. All undercut was removed acceptable. UT; Geom. ID root configuration. UT performed in lieu of RT.

200425 Pipe to Valve VT-1 VT-1, MT &, UT: no recordable 3993 Weld, W RT indications. VT-1:Insig. Arc MT strike R undercut 1/16" deep UT acceptable. UT; Geom. No downstream exam due to valve acceptable. UT performed in lieu of RT.

2 " Wld m t:

Summary NDE Exam Results 200080 Elbow to Pipe VT-1 VT-1,MT R RT: no recordable Weld, F4 RT indications. RT:Insig. Stringer MT pass weld contains fine 8c spot porosity. No change since last inspected on 1-26-87 acceptable.

200090 Elbow to Pipe VT-1 VT-1,PT 5, UT: no recordable Weld, V RT indications. VT-1:Insig. 2 pits MT 1/16" deep, acceptable. MT: no UT recordable indications on weld PT prep for UT-acceptable. UT:

Geom. Root Sc counterbore identified. Ut performed in lieu of RT.

13

\+

2

Summary NDE Exam Results 200530 Pipe to Pipe VT-1 VT-1, MT, PT & UT: no Weld, H2 RT recordable indications MT acceptable. VT-1; Insig. Light UT rust & minor pits < 1/32" PT acceptable. UT; Geom. ID root geometry acceptable. UT performed in lieu of RT

'200545 Pipe to Pipe VT-1 MT: Rej. 1/4" linear indication Weld, J RT and arc strikes from MT fabrication. PT: Rej. Linear UT pin hole indications. NCR 90-PT 123 generated and repairs made.

VT-1, UT & PT: no recordable indications -acceptable. VT-1:

Insig. Light rust. UT thickness readings were performed and acceptable. UT; Geom., ID and root configuration -acceptable. UT performed in lieu of RT, IL't

~: i=2!

Summary NDE Exam 'Results 200235 Pipe to Elbow VT-1 VT-1,MT & RT: no recordable

, Weld, B RT indications. RT:Insig. Weld MT spatter and spot porosity identified acceptable. No apparent change since last examination on 3-17-82 acceptable.

Summary NDE Exam Results 200295 Pipe to Elbow VT-1 VT-1 & MT: no recordable Weld, B RT indications'T:Insig ~ Fine MT and spot porosity identified.

No apparent change since last inspection on 3-19-82.

L J

II C,

Summary NDE Exam Results 200340 Pipe to Elbow VT-1 VT-1, RT &, MT: no recordable Weld, D RT indications. RT:Insig. Minor MT suckup, excessive root bead 8c spot porosity acceptable.

VT-1: Insig, undercut ( 1/32" acceptable. No apparent change since last examination in 1982 acceptable.

IL '

Summary NDE Exam Results 201000 Anchor Support, VT-3 VT-3, PT 8c MT: no recordable MSU-35 MT indications on areas accessible PT to examination. VT-3; Insig.

Grout cracked acceptable.

Summary NDE Exam Results 201200 Hydraulic Snubber VT-3 VT-3; No recordable indications Support, S10 acceptable. VT-3; Insig. Light rust on pipe clamp -acceptable.

Snubber SN¹ is 487620. Fluid reading of 1 7/16 was taken when the Temp. was 72 deg.

F..-acceptable.

Summary NDE Exam Results 201400 Hydraulic Snubber VT-3; No recordable indications Support, S20 acceptable. The Snubber is a Grinnell Size 3 type having a SN¹ of 11946. The piston position of 2 3/4" was obtained when the temperature was 72 deg. F.-acceptable.

f

'4'>>

Z gine: 14A-FW-900-1A Kl=

Summary NDE Exam Results 201600 Mechanical VT-3 VT-3; Rej. Insulation tight Snubber Support, against snubber 6" away on the FWU-21 clamp side. NCR 90-200 was generated for corrective action. Repairs were performed and the support reexamined-acceptable. The Snubber SNg is F-51035-1 that had a setting of 3 5/32" at a Temp. of 75 deg.

F ~ ~

HS=

Summary NDE Exam Results 201840 Hydraulic Snubber VT-3 VT-3; No recordable indications Support, FWU-39 acceptable. VT-3; Insig. Light rust acceptable. The Snubber SNg is 61642 which is a type PSA-35 that had a setting of 3 3/8 at a Temp. of 64 deg. F.

-acceptable. h 201841 Hydraulic Snubber MT MT; No recordable indications Integral Attachment acceptable.

FWU-39 M.

Summary NDE Exam Results 202040 Rigid Support VT-3 VT-3; No recordable indications FWU-29 acceptable.

L'>

pl JI

E. STEAM GENERATOR TUBING:

Summary NDE Exam Results 800000 Open Generator ET ET; All previous indications Tubes having >20X were examined to the previous identified extent of degradation as a degradation >20X. minimum. See the 1990 Eddy Current Examination Report for details.

800150 20% Rotating ET ET; 20X Random sample of all Random Sample on open unsleeved tubes were open Generator examined full length. Tube R3-Tubes. C39 was programed but not examined full length. See the 1990 Eddy Current Examination Report for details.

800200 100K of all ET ET; 100X of all open unsleeved tubes were examined to the 41

'nTubes.open Unsleeved Tubes Generator Tube Support on the Hot Leg.

See the 1990 Eddy Current Examination Report for details.

800350 20X Rotating ET ET; 20X Random sample of each Random Sample on type of sleeved Generator Tube

, each type of Sleeve. were examined from sleeve end to sleeve end as a minimum.

Sleeved Tube R19-C22 was programed (excess of 20X) but not examined. See,the 1990 Eddy Current Examination Report

~

for details.

~

NDE R'ummary Exam Results 801000 Open Generator ET ET; All previous indications Tubes having >20% were examined to the previous identified extent of degradation as a degradation >20X. minimum. See the 1990 Eddy Current Examination Report for details.

~i

Ã

Summary NDE Exam Results 801150 20K Rotating ET ET; 20X Random sample of all Random Sample on open unsleeved tubes were open Generator examined full length. See the Tubes. 1990 Eddy'urrent Examination Report for details.

801200 100X of all ET ET; 100X of all open unsleeved Unsleeved Tubes tubes were examined to the g1 on open Generator Tube Support on the Hot Leg.

Tubes. See the 1990 Eddy Current Examination Report for details.

801350 20X Rotating ET ET; 20X Random sample of each Random Sample on type of sleeved Generator Tube each type of Sleeve. were examined from sleeve end to sleeve end as a minimum.

See the 1990 Eddy Current Examinatio'n Report for details.

P. SYSTEM PRESSURE TESTS:

~Casa: 2 Summary NDE Exam Results 350710 RSSP-15.7.1 VT-2 VT-2: no recordable indications Charging System or leakage acceptable./

through the Regenerative Heat Exchanger.

Summary NDE Exam Results 361600 RSSP-13.16 VT-2, VT-2: no recordable indications CVCS "A" Holdup -acceptable. Cannot examine Tank under tank due to support.

361700 RSSP-13.17 VT-2 VT-2: no recordable indications CVCS "B" Holdup -acceptable. Cannot examine Tank under tank due to support.

361800 RSSP-13.18 VT-2 VT-2: no recordable indications CVCS "D" Holdup -acceptable. Cannot examine Tank under tank due to support.

I fi

,n

g,'~asks' g ~a 3 Summary NDE Exam Results 411000 PT-7 VT-2 VT-2: no recordable indications Leakage of acceptable. Insig. Boron Reactor Coolant residue found and reported to System the Station by work requests for the following; valve 392A bonnet, valve 700 packing, FIP 180, valve 924 bonnet bolts &

valve 427 -acceptable.

415300 PT-30, Containment VT-2 VT-2: no recordable indications Spray Rings, open all nozzles appear to have flow flow path test. -acceptable.

400800 CVCS Holdup Tanks VT-2 VT-2: no recordable indications

&. Piping or leakage acceptable.

400805 CVCS Charging VT-2 VT-2: no recordable indications Letdown outside or leakage acceptable.

containment 400820 CVCS Boric Acid VT-2 VT-2: no recordable indications Storage Tanks 8c, or leakage acceptable.

Piping 400825 CVCS Boric Acid VT-2 VT-2: no recordable indications Evaporizer- or leakage - acceptable.

Demineralizers.

401100 Diesel Generators VT-2 VT-2: no recordable indications or leakage acceptable.

ly G. SNUBBER PROGRAM:

1. /team Generator A ~raw n'ummary NDE Exam Results 600080 SGA-7 VT-3 No recordable indications.

Hydraulic Snubber Insignificant: Serial numbers Serial Number: 78t8 are inverted with each 77-28073-A other. Fluid level 1" from top. Temperature 65 F.

Setting 2 7/16" Acceptable.

600090 SGA-8 VT-3 No recordable indications.

Hydraulic Snubber Insignificant: Hammer marks Serial Number: on the snubber block. Serial 77-28073-A numbers 78c8 are inverted with each other. Fluid level 1".

No tag on No. 8. Temperature 65 F. Setting: 2 1/2" Acceptable.

~~a~~g:

Summary NDE Exam Results 600120 SGB-3 VT-3 No recordable indications.

Hydraulic Snubber Insignificant: No ID stamp Serial Number: on snubber. Temperature: 65 F.

77-28073-A Setting: 2 7/8" Acceptable.

600130 SGB-4 VT-3 No recordable indications.

Hydraulic Snubber Insignificant: No ID tag.

Serial Number: Hammer marks on snubber block 77-28073-A Temperature 65 F. Setting 2 1/2" Acceptable.

IL Draw~ ~o C-16 Summary NDE Exam Results 600200 AFU-03 VT-3 No recordable indications.

Mechanical Snubber Temperature 84 F.

Serial Number: Setting: 2" 20925 Acceptable.

Model PSA-1 q I I',

4 ~ 'ar 2 " 2

~Dawi~ ~C- E Summary NDE Exam Results 600220 AFU-31 VT-3 No recordable indications.

Mechanical Snubber Temperature: 100 F.

Serial Number: Setting: 2" Acceptable.

24452 Model PSA-1 600240 AFU-34 VT-3 No recordable Mechanical Snubber 98 F.

indications'emperature:

Serial Number: Setting: 2 7/8".

16379 Acceptable.

Model PSA-1

  • ~Dr win: ~C-Summary NDE Exam Results 600260 AFU-52 VT-3 No recordable ind'ications.

Mechanical Snubber Temperature: 100 F.

Serial Number: Setting: 1 3/4" ~

24453 Acceptable.

Model PSA-1

~aw~in  : g-18 Summary NDE Exam Results 600280 AFU-75 VT-3 No recordable indications.

Mechanical Snubber Temperature: 102 F.

Serial Number: Setting: 2".

20924 Acceptable.

Model 'PSA-1 600300 AFU-98 VT-3 No recordable indications.

Mechanical Snubber Temperature: 302 F.

Serial Number: Setting: 1 1/2".

24454 Acceptable.

Model PSA-1 lp Eq. E

~Dawin: C-1C Summary NDE Number Com onent Exam Results'o 600320 AFU-101 VT-3 recordable indications, Mechanical Snubber Temperature: 302 F.

Serial Number: Setting: 3 1/4" 15751 Acceptable.

Model PSA-1 600339 AFU-103 (EAST) VT-3 No recordable indications.

Mechanical Snubber Temperature: 67 F.

Serial Number: Setting: 2 5/8" 18184 Acceptable.

Model PSA-3 600340 AFU-103 (WEST) VT-3 No recordable indications.

Mechanical Snubber Temperature: 67 F.

Serial Number: Setting: 3 1/8" 18185 Acceptable.

Model PSA-3

.I ~Drawin 'C-

'ummary NDE Number Com onent Exam Results 600360 AFU-109 VT-3 Rejected: Bolt holding Hydraulic Snubber reservoir loose. NCR 90-104 Serial Number: Replaced with a new snubber, 30986 SN 30986. Temperature: 76 F.

Size 1.5 Setting: 2 3/4" Acceptable.

600380 AFU-111 VT-3 No recordable indications.

Mechanical Snubber Temperature: 76 F.

Serial Number: Setting: 2 1/4" 16377 Acceptable.

Model PSA-1 600400 AFU-123 VT-3 No recordable indications.

Mechanical Snubber Temperature: 290 Serial Number: 1 5/8" F.'etting:

16378 Acceptable.

Model PSA-1 600420 AFU-124 No recordable indications.

Mechanical Snubber Temperature: 290 F.

Serial Number: 244 Setting: 2" Model PSA-1 Acceptable.

4 i$

'rl

~n~ C- B ~Daw~i: B-3 1 Summary NDE Exam Results 600460 BDU-16 VT-3 No recordable indications.

Mechanical Snubber Temperature: 68 F.

Serial Number: Setting: 2 1/2" 10182 Acceptable.

Model PSA-5 6.

~aw~ Q-29 Summary NDE Exam Results 600530 CCU-43 VT-3 No recordable indications.

Mechanical Snubber Temperature: 68 F.

Serial Number: Setting: 1 1/8" 11462 Acceptable.

Model PSA-1

~~w'~ C-34 Summary NDE Exam Results 600610 CCU-57 VT-3 No recordable indications.

Mechanical Snubber Temperature: 65 F.

Serial Number: Setting: 2 3/8" 04160305 Acceptable.

Model PSA-3 8.

~Dgwi~n: Q-30 Summary NDE

~Exa Results 600710 CCU-71 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 64 F.

Serial Number: Setting: 2 1/2" 18193 Acceptable.

Model PSA-3

~ s 9 ~ 2 ~ch ~Ltdown:

~Drawin ~A-2 Summary NDE Number Com onent Exam Results 600880 CVU-26 VT-3 No Recordable Indications Mechanical Snubber Temperature: 50 F.

Serial Number: Setting: 2" 20880 Acceptable.

Model PSA-1

10. J J"

~ige,'VC ~ Q('eLaJLa 2 ~El~em~ ~rawin: ~S-Summary NDE Number Com onent Exam Results 600900 CVU-46 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 50 F.

Serial Number: Setting: 2 23517 Acceptable.

Model PSA 1/4 j)raw~i:- ~27 Summary NDE

~umber -Exam Resu ts 600920 CVU-49 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 48 F.

Serial Number: Setting: 1 1/2" 9483 Acceptable.

Model PSA 1/2

~CV S Let~ow~

elJJIJal ~Draw': B-32 Summary NDE Number Exam Results 600940 CVU-80 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 50 F.

Serial Number: Setting: 1 1/2" 23516 Acceptable.

Model PSA 1/4 II IV

12. ~eact r ~Coo ant ~Pum 1B Seal Water:

Summary NDE Number Com onent Exam Results 600960 CVU-103 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 66 F.

Serial Number: Setting: 2" 24450 Acceptable.

Model PSA-1 600980 CVU-104 VT-3 No Recordable Indications, Mechanical Snubber Temperature: 62 F.

Serial Number: Setting: 2" 24449 Acceptable.

Model PSA-1 13 Summary

'eactor ~Coo a t ~um ~1 NDE

~Sea

~Draw ':

~Wat r:

B-34 Results Number Exam 601000 CVU-186 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 60 F.

Serial Number: Setting: 1 5/8" 16541 Acceptable.

Model PSA-1

14. ~CV S ~Le dow

~rw~ B-35 Summary NDE Number Com onent Exam Results 601040 CVU-345 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 69 F.

Serial Number: Setting: 1 1/2" 9491 Acceptable.

Model PSA 1/2 601060 CVU-351 VT No Recordable Indications.

Mechanical Snubber Temperature: 63 F.

Serial Number: Setting: 1" 12508 Acceptable.

Model PSA 1/2

~ '

~Dx awin B-36 Summary NDE Number Com onent Exam Results 601080 CVU-372 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 63 F.

Serial Number: Setting: 7/8" 12917 Acceptable.

Model PSA 1/2=

15

~Dawi~ ~2 NDE

'ummary Number Com onent Exam Results 601100 FWU-3 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 69 F.

Serial Number: Setting: 4 1/16" 2500-10-153 Acceptable.

Model Berger Paterson Size 10 601110 FWU-5 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 69 F.

Serial Number: Setting: 2 1/2" 2500-10-152 Acceptable.

Model Berger Paterson Size 10 16.

~Daw~ B-13 Summary NDE Number Exam Results 601120 FWU-8 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 58 F.

Serial Number: Setting: 3 1/8" 8033 Acceptable.

Model PSA-10 601130 FWU-12 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 58 F.

Serial Number: Setting: 3" 8034 Acceptable.

Model PSA-10 1'I 17

'~ice: 14 -FW-900-1A ~aw~i: ~B- 1

'ummary NDE Number Com onent Exam Results 601140 FWU-15 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 241 F.

Serial Number: Setting: 2 5/8" 9358/51644 Acceptable.

Model PSA-35 601150 FWU-17 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Corrosion on Serial Number: housing. Tube marks on 9392 transition tube and housing.

Model PSA-35 Acceptable. Temperature: 242 F.

Setting: 5" Acceptable.

601160 FWU-18 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 211 F.

Serial Number: Setting: 4 3/4" 7067 Acceptable.

Model PSA-35 graw~n: ~HE-Summary NDE Number Com onent Exam Results 601170 FWU-20 VT-3 Reject: Top of snubber was Mechanical Snubber hitting mounting bracket. NCR Serial Number: 90-246: Angular tolerance OK.

7049 Clearance adequate. Use-as-Model PSA-35 is per E.K. Voci Acceptable.3" Temperature:79 F.; Setting:

Acceptable.

601180 FWU-21 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 220 F.

Serial Number: Setting: 3 11/16" F51035 Acceptable.

Model HSSA-20 601190 FWU-23 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 250 F.

Serial Number: Setting: 2 3/4" 8630 Acceptable.

Model PSA-10 601200 FWU-24 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 280 F.

Serial Number: Setting: 3" 10061 Acceptable.

Model PSA-10

~42, s,g<

'L l

L,

,4

Summary NDE Number Com onent Exam Results 601209 FWU-26 (EAST) No Recordable Indications.

Mechanical Snubber Temperature: 156 F.

Serial Number: Setting: 3" 18179 Acceptable.

Model PSA-3 601210 FWU-26 (WEST) No Recordable Indications.

Mechanical Snubber Temperature: 195 F.

Serial Number: Setting: 3" 18180 Acceptable.

Model PSA-3

/raw'i~ QE-5 Summary NDE Number Com onent Exam Results 601220 FWU-32 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 222 F.

Serial Number: Setting: 3 1/4" 7053 Acceptable.

Model PSA-35

~rw~n: ~1 Summary NDE Number Com onent Exam Results 601230 FWU-38 No Recordable Indications.

Mechanical Snubber Temperature: 260 F.

Serial Number: Setting: 2 3/4" 9395 Acceptable.

Model PSA-35 601240 FWU-39 No Recordable Indications.

Mechanical Snubber Temperature: 177 F.

Serial Number: Setting: 3 7/8" 9354/51642 Acceptable.

Model PSA-35 601250 FWU-40 No Recordable Indications.

Mechanical Snubber Temperature: 267 F.

Serial Number: Setting: 3 1/2" 7066 Acceptable.

'odel PSA-35 li 18

~pe: 4-B-FW-900-1B l~rawi~ HE-8

'ummary NDE Number Exam Results 601260 VT-3 Reject: Insulation on Mechanical Snubber valve 4012 resting on snubber; Serial Number: binding. Re-exam after repair.

No Recordable Indications.

6158 Model PSA-35 Temperature: 73 F,

'WU-42 Setting: 4 3/8" Acceptable.

601270 FWU-44 VT-3 Rejec't: Insulation not removed.

Hydraulic Snubber 1) Locknut not tight on snubber Serial Number: side. 2) Snubber does not move.

643864-20 3) No oil indicator.

Model HSSA-30 4) Reservoir on bottom.

5) Cotter Pin missing.
6) Turnbuckle not on print NCR 90-172 generated. Re-exam after repairs. Temperature: 75 F., Setting: 3 3/4",Acceptable.

601280 FWU-47 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Boot on snubber Serial Number: has rip with tape on it.

7474 Trouble card written for boot.

Model PSA-35 Temperature: 47 F., Setting:

4.875" Acceptable.

601290 FWU-48 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Very light Serial Number: corrosion that was cleaned 7475 off. Hole in'oot on bottom.

Model PSA-35 Temperature: 66 F.

Setting: 4 1/4" Acceptable.

601300 FWU-51 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Very light Serial Number: corrosion after cleaning.

7483 Temperature: 61 F.

Model PSA-35 Setting: 4 1/2". Setting on chart 4 3/8" -Acceptable.

601310 FWU-52 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 182 F.

Serial Number: Setting: 1.875" 8607 Acceptable.

Model PSA-10 601320 FWU-54 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 187 F.

Serial Number: Setting: 3 1/2" 7482 Acceptable.

Model PSA-35

Summary NDE Number Com onent Exam Results 601330 FWU-57 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 187 F.

Serial Number: Setting: 2.875" 10064 Acceptable.

Model PSA-10

19. Maia Steam ~Loo ~A

~Draw ': B-8 Summary NDE Number Com onent Exam Results 601350 MSU-2 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 68 F.

Serial Number: Setting: 3 1/4" 7048 Acceptable.

Model PSA-35 601360 MSU-3 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 67 F.

Serial Number: Setting: 3" 7060 Acceptable.

Model PSA-35 20 'a'n ~Si~aa~ ~Loo B:

~aw~in '-8 Summary NDE Number Com onent Exam Results 601369 MSU-7 (TOP) VT-3 No Recordable Indications.

Mechanical Snubber Insi,gnificant: No damage is Serial Number: apparent to snubber or rear 7051 brackets. Total movement is Model PSA-35 significant -2". Drag force present. Temperature: 80 F.

Setting: 2 3/4". Acceptable to ME-256 per A. Butcavage.

601370 MSU-7 (BOTTOM) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: No damage to Serial Number: snubber. Present movement 2".

7047 Drag force present.

Model PSA-35 Temperature: 80 F., Setting:

3". Acceptable to ME-256 per A.

Butcavage.

Summary NDE Number Com onent Exam Results 601380 MSU-8 VT-3 No Recordable Indications.

Hydraulic Snubber Insignificant: Snubber does Serial Number: not, move by hand. Temperature:

G-20968-1-30 100 F., Setting 3 1/2",

Model HSSA-20 Acceptable.

3 -B- S-6 0-1B ~Draw '~n'B- 1 0 Summary NDE Number Com onent Exam Results 601390 MSU-12 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Pigeon feces.

Serial Number: Acceptable per NCR 90-119.

9400 Temperature: 190 F.

Model PSA-35 Setting: 3.375" -Acceptable.

601399 MSU-13 (EAST) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Pigeon feces.

Serial Number: Acceptable per NCR 90-119.

1467 Temperature: 200 F.

Model PSA-100 Setting: 3.25" Acceptable.

601400 MSU-13 (WEST) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Pigeon feces, Serial Number: Acceptable per NCR 90-119.

1464 Temperature: 200 F.

Model PSA-100 Setting: 3.25" Acceptable.

601409 MSU-15 (NORTH) VT-3 No Recordable Indications, Mechanical Snubber Insignificant: Light rust; Serial Number: Does not rotate-acceptable.

7476 Temperature: 48 F., Setting: 3" Model PSA-35 Acceptable.

601410 MSU-15 (SOUTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust.

Serial Number: Does not rotate, acceptable.

7477 Temperature: 48 F., Setting:

Model PSA-35 3 1/4"> -Acceptable.

601419 MSU-16 (NORTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Pigeon feces.

Serial Number: Acceptable per NCR 90-119.

7481 Temperature: 190 F., Setting:

Model PSA-35 3.875" Acceptable.

IP 4.

s 'I, 4i P

~Drawin: B-10 Summary NDE Number Com onent Exam Results 1

601420 MSU-16 (SOUTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Pigeon feces.

Serial Number: Acceptable per NCR 90-119.

7480 Temperature: 205 F. Setting:

Model PSA-35 4.375" Acceptable.

601429 MSU-18 (NORTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Pigeon feces.

Serial Number: Acceptable per NCR 90-119.

93695 1645 Temperature: 180 F.,

Model PSA-35 Setting: 3.625" Acceptable.

601430 MSU-18 (SOUTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Pigeon feces.

Serial Number: Acceptable per NCR 90-119.

937251646 Temperature: 160 F.

Model PSA-35 Setting: 3.375" -Acceptable.

601439 MSU-19 (NORTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust.

Serial Number: Does not rotate. Acceptable.

9369 Temperature: 325 F.

Model PSA'-35 Setting: 4.25" -Acceptable.

601440 MSU-19 (SOUTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust.

Serial Number: Does not rotate. Accept.

9372 Temperature: 235 F.

Model PSA-35 Setting: 4.25" -Acceptable.

601450 MSU-22 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust'.

Serial Number: Does not rotate. Accept.

9357 Temperature: 235 F.

Model PSA-35 Setting: 4.375" -Acceptable.

601460 MSU-25 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust.

Serial Number: Does not rotate. Accept.

1465 Temperature: "235 F.

Model PSA-100 Setting: 4.125" -Acceptable.

I Summary NDE Exam Results 601469 MSU-26 (TOP) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust.

Serial Number: Does not rotate. Accept.

1465 Temperature: 235 F., Setting:

Model PSA-100 4.125", Acceptable.

601470 MSU-26 (BOTTOM) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust on Serial Number: attachment plate to pipe.

9389 Temperature: 235 F., Setting:

Model PSA-35 1.5" ,

Acceptable.

601480 MSU-27 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust.

Serial Number: Does not rotate. Accept.

9398 Temperature: 235 F., Setting:

Model PSA-35 4.5", -Acceptable.

601490 MSU-29 VT-3 No Recordable Indications Mechanical Snubber Insignificant: Does not Serial Number: rotate. Accept. Temperature:

1469 416 F., Setting: 4 1/8" Model PSA-100 Acceptable.

601500 MSU-31 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 416 F.

Serial Number: Setting: 2 5/8" 9356 Acceptable.

Model PSA-35 601510 MSU-32 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 292 F.

Serial Number: Setting: 2 1/2" 1093 Acceptable.

Model PSA-100

/

J'

21 ~ ~Ma'n ~St.ea ~Lo A:

~ awi~n: B-9 Summary NDE Number Com onent Exam Results 601520 MSU-38 VT-3 Reject: Snubber installed Mechanical Snubber backward to print. NCR 90-101.

Serial Number: Snubber may be installed 180 1090 deg. without change of Model PSA-100 function. Use-as-is. per E.K.

Voci. Acceptable.

601530 MSU-39 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Does not Serial Number: rotate. Accept.

1087 Temperature: 76 F.

Model PSA-100 Setting: 4 3/4" -Acceptable.

601540 MSU-40 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Does not Serial Number: rotate. Accept.

1080 Temperature: 416 F.

Model PSA-100 Setting: 4 5/8" -Acceptable.

601550 MSU-44 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Does not Serial Number: rotate. No ID tag. Accept.

1468 Temperature: 416 F.

Model PSA-100 Setting: 3 1/8" -Acceptable.

22 'KQX $ <CKR a'

~ RL 9 XQQ4 3UB~eQ=

-ILJOJLJR ~'aw~ ~B- 0 Summary NDE Number Com onent Exam Results 601560 MSU-55 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 109 F.

Serial Number: Setting: 1 5/8" 18195 Acceptable.

Model PSA-3 601570 MSU-57 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: No tag-Accept.

Serial Number: Temperature: 138 F.

15388 Setting: 2 1/4" Model PSA-3 Acceptable.

1 II

23 Summary Number

'Ma'n Com n:

~Stea onent

~Loo A' Inch NDE Exam

~Rise s

~Dawin v

B-9 Results 601580 MSU-58 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 170 F.

Serial Number: Setting: 2 1/4" 18187 Acceptable.

Model PSA-3 601590 MSU-60 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Corrosion Serial 18186 Number: from pipeline above Temperature: 169 F.

it -Accept.

Model PSA-3 Setting: 3" Acceptable.

24

@raw~ C-32

'ummary NDE Number Com onent Exam Results 601600 MSU-72 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 140 F.

Serial Number: Setting: 2 1/2" 15767 Acceptable.

Model PSA-3 601610 MSU-74 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 335 F.

Serial Number: Setting: 3 1/4" 10083 Acceptable.

Model PSA-10 601620 MSU-75 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 334 F.

Serial Number: Setting: 1,7/8" 8030 Acceptable.

Model PSA-10

~Dw~in ~C-Summary NDE Number Com onent Exam Results 601630 MSU-78 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 220 F.

Serial Number: Setting: 3" 8576 Acceptable.

Model PSA-10

Summary NDE Number Com onent Exam Results 601640 MSU-80 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 220 F.

Serial Number: Setting: 2 1/8" 18181 Acceptable.

Model PSA-3 601650 MSU-82 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 220 F.

Serial Number: Setting: 2 3/4" 15768 Acceptable.

Model PSA-3 601659 MSU-84 (EAST) VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 72 F.

Serial Number: Setting: 3 1/8" 18182 Acceptable.

Model PSA-3 601660 MSU-84 (WEST) VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 72 F.

Serial Number: Setting: 2 5/8" 18183 Acceptable.

Model PSA-3 601670 MSU-85 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 284 F.

Serial Number: Setting: 3 3/8" 10074 Acceptable.

Model PSA-10

25. ~w ~e~s ~Sa et ct'o

~L'~ ~A~0 ~Daw~

Summary NDE Number Exam Results 601680 RHU-8 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 61 F.

Serial Number: Setting: 2 5/8" 15755 Acceptable.

Model PSA-3 II

'l+

l~

26. ~R sidual Heat Removal:

~i~ 10A-A 7-250 ~raw'n: ~15 Summary NDE Number Exam Results 601690 RHU-30 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 61 F.

Serial Number: Setting: 1" 7065 Acceptable.

Model PSA-35 601700 RHU-33 VT-3 No Recordable Mechanical Snubber 61 F.

Indications'emperature:

Serial Number: Setting: 3 1/8" 7064 Acceptable.

Model PSA-35

-* ~Dr win: B-23 Summary NDE Number Com onent Exam Results 601710 RHU-36 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 64 F.

Serial Number: Setting: 2 1/2" 15756 Acceptable.

Model PSA-3 Summary NDE Number Com onent Exam Results 601720 RHU-51 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 76 F, Serial Number: Setting: 2 1/2" 15752 Acceptable.

Model PSA-3 601730 RHU-53 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 74 F, Serial Number: Setting: 2 3/4",

15754 Acceptable.

Model PSA-3 p

~ice: 6D-AC-601 ~Draw'n: B-26 Summary NDE Number Com onent Exam Results 601740 RHU-61 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 79 F.

Serial Number: Setting: 2 3/8" 15753 Acceptable.

Model PSA-3 Summary NDE Number Com onent Exam Results 601749 RHU-63 (NORTH) VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 64 F.

Serial Number: -Setting: 2 3/4" 16380 Acceptable.

Model PSA-1 601750 RHU-63 (SOUTH) VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Mortar under Serial Number: mounting plate is cracked.

16375 Acceptable per NCR 90-118, Model PSA-1 A.G. Goetz. Temperature: 64 F.

Setting: 3" Acceptable.

~Draw' 'B-Summary NDE Number Com onent Exam Results 601760 RHU-69 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 65 F.

Serial Number: Setting: 2 1/4" 8629 Acceptable.

Model PSA-10 601769 RHU-71 (NORTH) VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 63 F.

Serial Number: Setting: 2 1/2" 11466 Acceptable.

Model PSA-1 601770 RHU-71 (SOUTH) VT-3 No Recordabl'e Indications.

Mechanical Snubber Temperature: 63 F.

Serial Number: Setting: 2 1/2" 11465 Acceptable.

Model PSA-1

~E 1

~

4 ~t

27

~Dw~in: Q-20 NDE

'ummary Number Com onent Exam Results 601780 RHU-72 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 63 F.

Serial Number: Setting: 3" 8606 Acceptable, Model PSA-10

28. Residual ~Hat geqjova~

~D~awi >~ Q-20 Summary NDE Number Com onent Exam Results 601790 RHU-75 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 63 F.

Serial Number: Setting: 3 1/2" 8632 Acceptable.

Model PSA-10

+raw in@: ~B-2 Summary NDE Number Com onent Exam Results 601800 RHU-92 VT-3 No Recordable Indications.

Mechanical Snubber Insignificant: Light rust Serial Number: on base plate. Accept.

16376- Temperature: 63 F.

Model PSA-1 Setting: 2 1/4" -Acceptable.

29

~Dew ln: ~B-1

'ummary NDE

~em be r Com onent Exam Results-601810 RHU-109 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 79 F.

Serial Number: Setting: 2 1/4" 11463 Acceptable.

Model PSA-1 I

~ )

1 t

Summary NDE Number Com onent, Exam Results 601820 RHU-110 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 74 F.

Serial Number: Setting: 2 1/4" 16373 Acceptable.

Model PSA-1 Line: ~S-30 ~Dr aw ': ~1~6 Summary NDE Number Com onent Exam Results 601830 RHU-119 VT-3 No 'Recordable Indications.

Mechanical Snubber Temperature: 140 F.

Serial Number: Setting: 1 5/8" 15766 Acceptable.

Model PSA-3

~Drawin: 1i-19 Summary NDE Number Com onent Exam Results 601840 RHU-123 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 89 F, Serial Number: Setting: 2 1/2" 15765 Acceptable.

Model PSA-3 Line: 10 2-250 ~Draw Summary NDE Number Com onent Exam Results 601850 SIU-3 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 57 F.

Serial Number: Setting: 3.250" 8614 Acceptable.

Model PSA-10

~L'ne: -S 2- 50 ~Dawin: ~6 Summary -NDE Number Com onent Exam Results 601860 SIU-47 VT Reject: Snubber tang binding Mechanical Snubber on pipe clamp. Repaired under Serial Number: NCR 90-187. No Recordable 15349 Indications, Acceptable.

Model PSA-3 Temperature: 72 F.

Setting: 3 3/8" -Acceptable.

r'g 0,

g I

30. Resi1Lnn,'Bat removal:

~D~wi~n: A-14 Summary NDE Exam Results 601870 SIU-52 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 69 F.

Serial Number: Setting: 2 9/16" 15348 Acceptable.

Model PSA-3 31 ~ e ': 1 6 1ll' ma w ~Dawin: C-13 Summary NDE Number Exam Results 601890 SWU-254 VT-3 Rejected: Loose nuts on west Mechanical Snubber side of snubber pipe clamp.

Serial Number: Repaired under NCR 90-208.

12508 Temperature: 42 F.

Model PSA 1/2 Setting: 1 1/8" -Acceptable.

~Drawin: C-14 Summary NDE Number Exam Results 601900 SWU-308 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 49 F.

Serial Number: Setting: 2 3/4".

8031 Acceptable.

Model PSA-10

~'la.

601910 SWU-309 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 49 F.

Serial Number: Setting: 3 1/4" 10073 Acceptable.

Model PSA-10 32 ' - ~ a-' e- w Penetrat'on ~31 -32

~DawiDR: ~C- 6B Summary NDE Number Exam Results 601920 SWU-370 VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 45 F, Serial Number: Setting: 2 1/4" 11464 Acceptable.

Model PSA-1 "J

7.

33

~D~w'~n: C-24

'ummary NDE Number Corn onent Exam Results 601930 AFU-205 (AFW-10) VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 81 F.

Serial Number: Setting: 3" 12900 Acceptable.

Model Grinnell Size 1 1/2 Fight AFU-208 (AFW-13) VT-3 Reject: Cold setting 2 1/16" 601940 Hydraulic Snubber should be 3 1/2". NCR 90-109 Serial Number: generated. Gilbert Scales show 21010 proper setting to be 2 1/2".

Model Grinnell Revise ME-256 Use-as-is per

~f 8r.

200 E.K. Voce Temperature: 66 F.

Setting: 2 1/16" -Acceptable.

34. IL M '

+raw~ C-20 Summary NDE Number Com onent Exam Results 601950 AFW-25 VT-3 Other: This snubber has been Hydraulic'nubber removed from the line under seismic upgrade program phase

10. Removed from Snubber program.

601960 AFW-26 VT-3 Other: This snubber has been Hydraulic Snubber removed from the line under seismic upgrade program phase

10. Removed from Snubber program.

601970 AFU-226 (AFW-27) VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 86 F.

Serial Number: Setting: 3 1/8" 12901 Acceptable.

Model Grinnell Size 1 1/2 601980 AFU-224 (AFW-28) VT-3 No Recordable Indications, Hydraulic Snubber Temperature: 86 F.

Serial Number: Setting: 2 1/2" 12905 Acceptable.

Model Grinnell Size 1 1/2

0 4

r

Summary NDE Number Com onent Exam Results 601990 AFU-225 (AFW-29) VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 85 F.

Serial Number: Setting: 1 3/4" 12906 Acceptable.

Model Grinnell Size 1 1/2 602000 AFU-227 (AFW-31) VT-3 No Recordable Indications.

Mechanical Snubber Temperature: 69 F.

'"'l Serial Number: Setting: 4 1/4" 25594 Acceptable.

Model PSA-3 35 'I'L

~Drawin S-2 Summary NDE Number Com onent Exam Results 602010 N601 VT-3 Reject: Snubber hits base Hydraulic Snubber plate at wall has no ID tag.

8D Serial Number: NCR 90-184 generated. Base 6565 plate does not impair function.

Model Grinnel Use-as-is per E.K. Voci. New Size 2 ID tag installed. Temperature:

66 F., Setting: 3" -Acceptable.

602020 N602 VT-3 Reject: No ID tag. NCR 90-184 Hydraulic Snubber generated, ID tag installed.

Serial Number: Temperature: 66 F.

6568 Setting: 2 1/4" Model Grinnell Acceptable.

Size 2 Summary NDE

~aw~ ~S-Number ,Exam Results 602030 N604 VT-3 Reject: No ID tag. NCR 90-184 Hydraulic Snubber generated. ID tag installed.

Serial Number: Temperature: 66 F.

6566 Setting: 1 1/2" Model Grinnell Acceptable.

Size 2 602040 N605 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 66 F.

Serial Number: Setting: 2 3/4" 6561 Acceptable.

Model Grinnell Size 2 ch g,l

Summary NDE Number Com onent Exam Results 602050 N607 VT-3 Reject: No ID tag. NCR 90-184 Hydraulic Snubber generated. ID tag installed.

Serial Number: Temperature: 66 F.

6562 Setting: 3 1/2" Model Grinnell Acceptable.

Size 2 602060 N608 VT-3 Reject: Snubber has no ID tag 5, Hydraulic Snubber hits base plate. NCR 90-184 Serial Number: generated. The Snubber hitting 6563 base plate does not impair its Model Grinnell function. Use-as-is per E.K.

Size 2 Voci. New ID tag installed.

Temperature: 66 F.

Setting: 3 3/4" -Acceptable.

/raw~ S-2 Summary NDE Number Com onent Exam Results 602070 N615 VT-3 Reject: No ID tag. NCR 90-184 Hydraulic Snubber generated. ID tag installed.

Serial Number: Temperature: 64 F.

6564 Setting: 2 3/8" Model Grinnell Acceptable.

Size 2 Qrawirri: S-2 Summary NDE Number Com onent Exam Results 602080 N616 VT-3 Reject: Cotter key broken off Hydraulic Snubber at top near wall, no ID tag.

Serial Number: NCR 90-184 generated. Key 6567 repaired R ID tag installed.

Model Grinnell Temperature: 65 F.

Size 2 Setting: 2 5/8" -Acceptable.

36 :2

'&'DE awi~

Exam'D

'ummary Number Results 602090 PS-2 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 63 F.

Serial Number: Setting: 4" PD872-39-1244 Acceptable.

Model Paul Monroe PMH2103

'h 45

Summary NDE Number Corn onent Exam Results 602100 PS-4 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 63 F.

Serial Number: Setting: 1" PD86144-1152 Acceptable.

Model Paul Monroe. PMH 2103

~Draw in: S-1 Summary NDE Number Com onent Exam Results 602110 PS-5 VT-3 Reject: Cotter key at top not Hydraulic Snubber engaged 100K 8c deformed. NCR Serial Number: 90-112'enerated for repairs.

PD87767-1246 Re-examined after repairs.

Model Temperature: 65 F.

Paul Monroe PMH 2103 Setting: 2 5/8" -Acc'eptable.

602120 PS-6 VT-3 Reject: Broken cotter key/lack Hydraulic Snubber of thread engagement at clamp Serial Number: end. NCR 90-112 generated.

PD87767-1239 Re-examined after repairs.

Model Insignificant: Lack of thread Paul Monroe -PMH 2103 engagement acceptable per design analysis by W. Tomo.

602130 . PS-8 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 65 F, .

Serial Number: Setting: 2 3/4" 86144-1159 Acceptable.

Model Paul Monroe PMH 2103 602140 PS-9 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 65 F.

Seri'al Number: Setting: 3" 86144-1154 Acceptable.

Model Paul Monroe PMH 2103 602150 PS-10 VT-3 No Recordable Indications.

Hydraulic Snubber Temperature: 66 F.

Serial Number: Setting: 3 5/8" 86144-1157 Acceptable.

Model Paul Monroe PMH 2103 T

~rawin: S-1A Summary NDE Number Com onent Exam Results 602160 PS-11 VT-3 No Recordable Indications.

Hydraulic. Snubber Temperature: 65 F.

Serial Number: Setting: 2 5/16" PD86144-1156 Acceptable.

Model Paul Monroe PMH 2103 H. SNUBBER PROGRAM FUNCTIONAL TESTING:

~Draw ': ~A-Summary NDE Number Com onent Exam Results 600081 SGA-7 FT Functionally tested and Hydraulic Snubber acceptable.

2 ~

~Dawin Summary NDE Number Exam Results 600341 AFU-103 (EAST) FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

18184 Model PSA-3 600342 AFU-103 (WEST) FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

18185 Model PSA-3

/raw~i'C-Summary NDE Number Com onent Exam Results 600361 AFU-109 FT Functionally tested S/N Hydraulic Snubber 15403. Installed new snubber Serial Number: S/N 30986 acceptable.

30986 Size 1.5

1 Summary NDE Exam Results 600381 AFU-111 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

16377 Model PSA-1

3. Reactor coolant ~P m 1B ~Sea Water:

~Dr w'n: B-33 Summary NDE Exam Results 600961 CVU-103 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

24450 Model PSA-1 Functionally tested

'00981 CVU-104 FT and Mechanical Snubber acceptable.

Serial Number:

24449 Model PSA-1

4. CWCS ~Ltdow

~Dr win: B-35 Summary NDE Number Com onent Exam Results 601041 CVU-345 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

9491 Model PSA 1/2

~D. awi~ gE-5 Summary NDE Exam Results 601171 FWU-20 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

7049 Model PSA-35 w"p

~L'ne: 14-B- W-900-19 ~Dewin: HB-8 Summary NDE Number Exam Results 601291 FWU-48 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

7475 Model PSA-35 601301 FWU-51 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

7483 Model PSA-35

7. Residual geea, ~eoval:

~awi~n B-20 Summary NDE Exam Results 601761 RHU-69 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

8679 Model PSA-10

@iLne: 0 -S 2-2 0 ~Daw:Lnn Summary NDE

'esults Exam 601861 'IU-47 FT Functionally tested and Mechanical Snubber acceptable, Serial Number:

15349 Model PSA-3 if '

ff4

9 ~ Service ~Wate to A & Q ~D'esel Generator Water Coolers:

~Drswin: 0-13 Summary NDE Number Com onent Exam Results

'601891 SWU-254 FT Functionally tested and Mechanical Snubber acceptable.

Serial Number:

12508 Model PSA 1/2 10 ~ l' s g Steam Generator Feedwater ~~e ~

I '" ~rawin '-20 Summary NDE Number Com onent Exam Results 602001 AFU-227 (AFW-31) FT Functional test not required Mechanical Snubber on this snubber in 1990.

Serial Number: Snubber AFU-109 was 25594 substituted per G. Wahl.

Model PSA-3 I' 'U '

~raw n:

u~

'S-2

~

Summary NDE Number Com onent Exam Results 602041 N605 FT Functionally tested and Hydraulic Snubber acceptable.

Serial Number:

6561 Model Grinnell, Size 2 12 ~Powe P e u

~R~eg,'DE Qg~w'~n: ~S-1

'ummary Number Com onent Exam Results 602161 PS-11 FT Functionally tested and Hydraulic Snubber acceptable.

Serial Number:

PD86144-1156 Model Paul Monroe PMH 2103 qi'

  • kg

/'

GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990 1999 Interval, First Outage 1990 Attachment II Erosion/Corrosion (Minwall) Summary Report This section provides a detailed listing of components and associated examination results on items that were inspected during the 1990 Ginna Outage. A total of 312 components were examined.

Chart number 1 shows by graphic display the types of components that were examined. This chart also provides an overall display of

,components in relationship to the percentage of nominal wall remaining. Out of a total number of 312 components; 17 components had less than 65X nominal wall remaining.

Table number 1 provides a complete listing of items by components that were examined during the 1990 Ginna Outage. If the listed component had examination results in 1989, the results of that, examination is specified along with the results of the 1990 inspection. The percentage of Nominal Wall remaining by component is also included for reference.

1990 Minwall Examination Program and Results:

The following listing identifies the systems, the types of components within the system, the examination result breakdown as a percentage of nominal wall remaining as well as the reference drawing that identifies the component within the specified system.

Drawing System

~o. +ice M-1 A/B Feedwater Pump Discharge to 5 A/B Heater.

Results:

2 Pipes 1 >88X of nominal 1 88-82X of nominal M-4B Feedwater Cleanup to Condenser East Wall.

Results:

4 Elbows 1 >88X of nominal 2 Pipes 2 88-82X of nominal 2 Reducers 1 82-76X of nominal 4 76-70X of nominal Heaters 4 A/B to Feedwater Suction.

Results:

2 Elbows 3 >88X of nominal 2 Pipes 2 88-82X of nominal 1 Tee

~

'lMf p "1

Drawing System No. Title M-7B Condensate Pump h Heater Drain Tank Discharge to Feedwater Suction.

Results:

1 Elbow 6 >88X of nominal 3 Pipes 2 Tees M-10 Low Pressure Downcomers.

Results:

1 Pipe 1 76-70X of nominal M-10A Low Pressure Downcomers in West Condenser.

Results:

5 Elbows 6 >88X of nominal 17 Pipes 10 88-82X of nominal 2 82-76X of nominal 2 76-70X of nominal 2 <65X of nominal M-10B Low Pressure Downcomers in East Condenser.

Results:

7 Pipes 5 88-82% of nominal 1 82-76X of nominal 1 <65X of nominal M-11A .MSR lA, 1B 2nd Pass Drain.

Results:

2 Elbows 3 >88X of nominal 2 Pipes 1 88-82X of nominal M-11B MSR 2A, 2B 2nd Pass Drain.

Results:

1 Pipe 1 >88X of nominal 2 Tees 2 88-82X of nominal M-12A MSR 1A, 1B 2nd Pass Drain to 5A H.P.H. & Condenser.

Com onents Examined: Results:

2 Elbows 3 >88X of nominal 3 Pipes 1 88-82X of nominal 1 Tee 1 82-76X of nominal 1 76-70X of nominal M-12B MSR 2A,. 2B 2nd Pass Drain to 5B H.P.H. k, Condenser.

Results:

2 Elbows 4 >88X of nominal 3 Pipes 1 88-82X of nominal 2 Reducers 3 82-76X o'f nominal 1 Tee

A l

j1 0

+l

System

~T'ie MSR 1A 4th Pass to 5A Heater.

Results:

2 Elbows 1 >88X of nominal 1 88-82X of nominal MSR 1B 4th Pass to GB Heater.

Results:

2 Elbows 1 >88X of nominal 1 88-82%'of nominal MSR 1A & 1B 4th Pass to Condenser.

Results:

2 Elbows 2 88-82X of nominal MSR 2A 4th Pass to GA Heater.

Results:

1 Elbow 1 >88X of nominal MSR 2B 4th Pass to GB Heater.

Results:

2 Elbows 2 >88X of nominal 1 Pipe 1 88'-82X of nominal MSR 2A &. 2B 4th Pass to Condenser.

Results:

5 Elbows 8 >88X of nominal 5 Pipes 4 88-82X of nominal 2 Tees 1A, 2A & 3A L.P.H. Drains to Condenser.

Results:

2 Elbows 3 >88X of nominal 3 Reducers 1 88-82X of nominal 1 82-76X of nominal Steam Extraction to Preseparator B & 4B L.P.HE Results:

10 Elbows 11 >88X of nominal 9 Pipes 3 88-82X of nominal 1 Reducer 1 82-76X of nominal 1 Tee 4 76-70X of nominal 1 Downcomer (pipe) 1 70-65X of nominal 2 <65% of nominal

P fE J

Drawing System NcC, ~T'~e M-22 Steam Extraction to Preseparator A Sc 4A L.P.H.

Results:

5 Elbows 4 88-82X of nominal 4 Pipes 3 82-76X of nominal 1 Reducer 2 76-70X of nominal 1 Tee 3 <65X of nominal 1 Downcomer (pipe)

M-27 Condensate Booster Pumps to Hydrogen Coolers.

Results:

1 Elbow 1 >88% of nominal 1 Pipe 1 82-76X of nominal M-28 Condensate Booster Pumps to Hydrogen Coolers.

Results:

1 Elbow 1 >88X of nominal M-31 MSR 1A & 1B to Heater Drain Tank.

Results:

2 Elbows 2 >88X of nominal 1 Tee 1 88-82X of nominal M-32 MSR 2A 8r. 2B to Heater Drain Tank.

Results:

5 Elbows 9 >88X of nominal 3 Pipes 1 Reducer M-41A 5A H.P.H. Drain to 4A L.P.H.

1 Reducer 1 >88X of nominal M-41B GB H.P.H. Drain to 4B L.P.H.

1 Elbow 2 >88X of nominal 1 Pipe M-45 Preseparator A/B to Heater Drain Tank &, Condenser.

Results:

1 Pipe 1 76-70X of nominal M-46A Preseparator A/B to Heater Drain Tank 8r, Condenser.

Results:

1 Elbow 82-76X of nominal

e.

System Title Preseparator A/B to Heater Drain Tank.

Results:

1 Pipe 3 >88X of nominal 2 Reducers Turbine Driven Auxiliary Feedwater Pump to Discharge Lines.

Results:

5 Elbows 7 >88X of nominal 3 Pipes 2 88-82X of nominal 1 Tee Auxiliary Feedwater Pump A to Discharge Lines.

Results:

2 Elbows 3 >88X of nominal 1 Pipe Auxiliary Feedwater Pump B to Discharge Lines.

Results:

1 Pipe 1 >88X of nominal Steam Extraction to 5A Sc 5B H.PoH.

Results:

1 Elbow 5 >88X of nominal 4 Pipes 2 88-82X of nominal 2 Reducers 4 <65X of nominal 2 Tees 2 Nozzles Feedwater Discharge, Turbine Building.

Results:

1 Reducer 1 76-70X of nominal Steam Generator Blowdown Lines, (Intermediate Building)

Results:

7 Elbows 6 >88X of nominal 7 Pipes 2 88-82X of nominal 4 76-70X of nominal 1 70-65X of nominal 1 <65X of nominal Steam Generator Blowdown Lines, (Turbine Building)

Results:

4 Elbows 8 >88X of nominal 6 Pipes 2 88-82X of nominal 1 Lateral 1 <65X of nominal

dk wt II~

I I

I'I t

Drawing System goo. /itic M-89A Steam Generator 1A Blowdown Lines, (Containment Building)

Results:

6 Pipes 10 >88X of nominal 3 Tees 1 Nozzle, M-89B Steam Generator 1B Blowdown Lines, (Containment Building)

Results:

4 Pipes 3 >88X of nominal 1 Tee 2 88-82X of nominal M-89C Steam Generator 1B Blowdowm Lines (Containment Building)

Results:

1 Elbow 3 >88X of nominal 3 Pipes 2 88-82X of nominal 2 Tees 1 82-76X of nominal M-90 Feedwater Recirculation (CV-10).

Results:

1 Pipe 1 70-65X of nominal Feedwater Recirculation (CV-19),

Results:

1 Elbow 1 70-65X of nominal M-92 Main Feedwater Pump Bypass.

Results:

2 Elbows 1 >88X of nominal 1 76-70X of nominal M-94 Steam Generator Blowdoun to Condenser.

Results:

8 Elbows 15 >88X of nominal 10 Pipes Housel'esults:

3 88-82X of nominal M-SW Service Water in Screen 8 Elbows 21 >88X of nominal 15 Pipes 6 88-82X of nominal 4 Tees N/A Heater Drain Tank to Condenser.

Summary Numbers 400001 to 400002 Results:

2 Elbows 2 >88X of nominal

l Drawing System

~o ~ Tii]e IP N/A Main Steam Dump to Condenser.

Summary Numbers 400003 to 400004 Results:

2 Reducers 2 >88X of nominal N/A Blowdown Tank to Condenser.

Summary Numbers 400005 to 400006 Results:

1 Elbow 2 >88X of nominal 1 Pipe N/A Blowdown Tank to 3A Low Pressure Heater.

Summary Numbers 400007 to 400008 Results:

1 Elbow 2 >88X of nominal 1 Pipe N/A Gland Steam Discharge to Gland Steam Condenser.

Su'mmary Numbers 400009 to 400010 Com onents Examined: Results:

1 Elbow 2 >88X of nominal 1 Lateral N/A Preseparator Drain to Preseparator Vent.

Summary Numbers 400011 to 400015 Results:

1 Elbow 4 >88X of nominal 3 Pipes 1 <65X of nominal' Tee N/A 4B Low Pressure Heater Vent.

Summary Numbers 400016 to 400025 Results:

3 Elbows 9 >88X of nominal 5 Pipes 1 Tee N/A Steam Extraction To 4A Low Pressure Heater.

Summary Numbers 400047 to 400058 Results:

12 Pipes 6 76-70X of nominal 4 70-65X of nominal 2 <65X of nominal

kt 9 1 ebl

Component Respectable Dispositions:

The following listing of Dispositions provides information on components that have less than 70X of Nominal Wall remaining.

f~s.em: Low Pressure Downcomers in West Condenser.

Component Dwg. ID Summar No. No. No. NCR No. Dis osit.ion 212180 M-10A 18 90-143 Engineering Evaluation, "use-as-is", Reexamine during 1992 outage.

212190 M-10A 19 90-143 Engineering Evaluation, "use-as-is", Reexamine during 1992 outage.

~S t~e~ Low Pressure Downcomers in East Condenser.

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 213060 M-10B 2F 90-142 Engineering Evaluation, "use-as-is", Reexamine during 1992 outage.

~S stem: Feedwater Recirculation (CV-18) ~

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 300440 M-90 43 89-312 No change since last exam during 1989 outage.

~a~t n: Feedwater Recirculation (CV-19),

Component Dwg. ID Summar No, No. No. NCR No. Dis osition 300840 M-91 38 89-279 No change since last exam during 1989 outage.

~tern: Steam Extraction to Preseparator B &, 4B L.P.H.

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 301270 M-21 25 90-128 Component was Replaced.

301290 '-21 27 90-128 Component, was Replaced.

-301300 M-21 28 90-128 Engineering Evaluation, use &s is ~

N

~S st~ Steam Extraction to Preseparator A & 4A L.P.H.

Component Dwg. ID Dis ositi:on 302010 M-22 28 90-131 'ngineering Evaluation, II use-as-is II 302020 M-22 29 90-131 First 20" of component was Replaced.

302130. M-22 38 90-131 Component was Replaced.

~S can'team Extraction to 5A &, 5B H.P.H.

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 303015 M-75 1A 90-168 Component was Replaced.

303017 M-75 1B N/A Component was "pad welded" from I.D. when downstream component was Replaced.

303165 M-75 16A 90-168 Component was Replaced.

303167 M-75 16B N/A Component was "pad welded" from I.D. when downstream component was Replaced.

~S i~taa Steam Generator Blowdown Lines, (Intermediate Building)

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 304425 M-88A 2A 90-150 Adjacent fillet welds were reworked to give a concave shape to reduce stresses.

304435 M-88A 3A 90-150 Adjacent, fillet welds were reworked to give a concave shape to reduce stresses.

Qgg~terg: Steam Generator Blowdown Lines, (Turbine Building)

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 385800 M-88D 80 90-215 Welded rolled plate to O.D.

~i~m'reseparator Drain to Preseparator Vent.

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 400014 N/A N/A 90-216 Engineering Evaluation, II use-as-is tt

~t~ Steam Extraction To 4A Low Pressure Heater.

Component Dwg. ID Summar No. No. No. NCR No. Dis osition 400051 N/A 5 90-131 Engineering Evaluation, ft use-as-is It 400053 N/A 90-131 'ngineering Evaluation, "use-as-is".

400054 N/A 90-131 Engineering Evaluation, "use-as-is",.

400056 N/A 90-131 Engineering Evaluation, "use-as-is".

400057 N/A 90-131 Engineering Evaluation, "use-as-is".

400058 N/A A 90-131 Engineering Evaluation, "use-as-is".

I1 l\

W

}

~ .

MlNWALL MINWALL 1990 GINNA OUTAGE 1990 GINNA OUTAGE 154 160 200 180 140 120 108 150 100 80 100 64 60 40 28 50 19 27 16 17 20 0 0 PIPES ELBOV/S TEES REDUCERS NOZZLES >88% 88-82% 82-76% 76-70% 70-65% >65%

NUhSER OF EACH OOMPONENT TYPE PERCENTAGE OF NOMINAL THAT WAS EXAMNED WALL REhWNING Chart I

J IP I

Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL

    • DRAWING NUMBER M-1 200010 1 P 0.602 0.595 88-82 200015 1A P 0.534 0.669 >88

"* DRAWING NUMBER M-4B 204510 51 0.481 0.483 82-76 204520 52 E 0.494 0.494 88-82 204570 57 E 0.434 0.436 76-70 204590 59 E 0.458 0.448 76-70 204600 60 P 0.495 0.444 76-70 204610 61 E 0. 453, 0.491 88-82 204630 63 R 0.469 0.454 76-70 204840'4 P 0.209 0.247" ">88

    • DRAWING NUMBER 205040 4 E 0. 323 88-82 205050 5 P 0.342 >88 205160 16 E 0.319 88-82 205170 17 P 0.365 >88 205250 25 T 0.505 >88
    • DRAWING NUMBER M-7B 208550 55 T 0.395 >88 208600 60 P 0.298 >88 208610 61 E 0.303 >88 208620 62 P 0.310 >88 208630 63 T 0.362 >88 208640 64 P 0.336 >88
  • '* DRAWING NUMBER M-10 211060 1F P 0.151 0.273 76-70
    • DRAWING NUMBER M-10A 212010 1 P 0.334 >88 212020 2 E 0. 299 >88 212030 3 P 0.324 88-82 212040 4 E 0.327 88-82 212050 5 P 0.333 >88 212060 6 P 0.343 >88 212070 7 E 0.329 88-82 212080 8 P 0.326 88-82 212090 9 E 0;344 >88 212100 10 P 0.324 88-82 212110 11 P 0.344 >88 212120 12 P 0.322 88-82 212130 13 P 0.329 88-82 212150 15 E 0.322 88-82 212160 16 P 0.281 76-70 212180 18 P 0.169 <65 212190 19 P 0.169 <65 Table 1

l f

4 t,

Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL 212200 20 0.314 88-82 212210 21 0.302 82-76 212220'2 0. 318'.

88-82 212230 23 281 76-70 212240 24 0.289 82-76

    • DRAWING NUMBER M-10B 213010 2A P 0. 329 88-82 213020 2B P 0.322 88-82 213030 2C P 0.291 82-76 213040 2D P 0.308 88-'82 213050 2E P 0.317 88-82 213060 2F P 0. 176 <65 213070 2G P 0. 318 88-82
    • DRAWING NUMBER M-11A 215410 41 P 0. 456 >88 215411 41A E 0.358 88-82 215412 41B P 0. 424 >88 215420 42 E 0.388 >88
    • DRAWING NUMBER M-11B ~

216100 88 T 0.363 0. 470 >88 216300 108 P 0.375 0.371 88-82 216440 122 T 0.315 0.358 88-82

    • DRAWING NUMBER M-12A 222280 26 P 0.361 0.361 88-82
    • DRAWING NUMBER M-12B 222490 47 R 0. 302 88-82 222495 47B P 0.394 >88 222500 48 E 0.429 82-76 222510 49 P 0.386 >88 222890 87 E 0.332 82-76 222900 88 P 0.357 . 0.343 82-76 222905 88A R 0.456 >88 222910 89 T 0.497 , 0.584 >88
    • DRAWING NUMBER M-12A 223040 101 E 0.372 0.446 >88'88 223050 102 P 0.400 223080 105 E 0.346 82-76 223090 106 P 0.316 0.304 76-70 223095 106A R 0.421 >88
    • DRAWING NUMBER M-15A 226250 25 E 0.259 0.258 88-82 226480 48 E 0.246 0.307 >88 Table 1

~,

I

Page No.

05/15/90

SUMMARY

COMP TYPE 1989'IN ~ 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL

    • DRAWING NUMBER M-15B 227440 96 E 0.253 0.299 >88 227500 102 E 0.265 0.285 88-82 DRAWING NUMBER M-16 228060 6 E 0.235 0.260 88-82 228270 27 E 0.288 0.287 88-82
    • DRAWING NUMBER M-17A 230410 41 E 0.271 0.316 >88

"* DRAWING NUMBER M-17B 231020 52 E 0.353 0.372 88-82 231410 91 P 0.255 0.313 >88 231420 92 E 0.240 0.297 >88

    • DRAWING NUMBER M-18 232070 7 E 0.283 >88 232080 8 P 0.266 88-82 232090 9 E 0.275 88-82 232100 10 P 0.291 >88 232260 26 T 0.338 >88 232330 33 E 0.277 88-82 232340 34 P 0.298 >88 232350 35 E 0.291 >88 232360 36 P 0.293 >88 232520 52 T 0.309 88-.82 232580 58 E 0.481 >88 232590 59 P 0.540 >88
    • DRAWING NUMBER M-19 234405 40A E 0.306 0.334 82-76 234420 42 E 0.360 0.362 88-82 234455 45A R 0.374 >88 234457 45B R 0.366 >88 234465 46A R 0.281 >88
    • DRAWING NUMBER M-27 253260 26 P 0.309 0.307 82-76 253270 27 E 0.302 0.357 >88

"* DRAWING NUMBER M-28 254250 25 E 0.312 0.385 >88

    • DRAWING NUMBER M-31 260020 2 T 0.359 0.466 >88 260241 24A E 0.384 >88 260242 24B E 0.363 88-82 Table 1

e Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL

"* DRAWING NUMBER M-32 261380 38 E 0.396 ~,>88 261390 39 P 0.388 >88 261400 40 E 0.392 >88 261410 41 P 0.390 >88 261420 42 E 0.412 >88 261430 43 R 0.320 >88 261460 46 E 0.533 >88 261470 47 E 0.612 >88 261500 50 P 0.547 >88

    • DRAWING NUMBER M-92 281200 20 E 0.450 76-70 281310 31 E 0.351 0.351 >88
    • DRAWING NUMBER M-41A 290016 1B R 0.447 >88
    • DRAWING NUMBER M-41B 291020 41 E 0.417 >88 291030 42 P 0.407 >88
    • DRAWING NUMBER M-45 298520 52 P 0.332 0.319 76-70

"* DRAWING NUMBER M-90 300440 43 P 0.297 0.298 70-65

    • DRAWING NUMBER M-91 300840 '38 E 0.291 0.297 70-65
    • DRAWING NUMBER M-21 301025 2A D 0.362 0.351 76-70 301040 4 P 0.703 >88 301050 5 E 0.809 >88 301100 10 R 0.759 >88 301180 17 E 0.759 >88 301250 23 P 0.400 82-76 301260 24 E 0.267 76-70 301270 25 P 0. 151 <65 301280 26 E 0.324 88-82 301290 27 P 0.233 <65 301300 28 E 0.258 70-65 301310 29 P 0.275 76-70

'301320 30 T 0.496 0.473 76-70 301390 37 E 0.309 88-82 301400 37A P 0.342 >88 301405 39B P 0.333 >88 301410 38 E 0.312 88-82 301420 39 P 0.354 >88 Table 1

W

~\

I' 1

'Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL 301425 39A E 0.338 >88 301430 40 E 0. 356 >88 301450 42 P 0.361 >88 301470 44 E 0.374 >88

    • DRAWING NUMBER M-22 301705 1B D 0.342 0.400 82-76 301780 9 E 0.669 0.676 76-70 301830 14 R 0.733 88-82 302010 28 P 0.320 <65 302020 29 P 0.155 <65 302030 30 E 0.328 88-82 302090 35 E 0.332 0.311 88-82 302110 37 T 0.502 0.498 76-70 302120 37A P 0.300 82-76 302130 38 E 0.185 <65 302140 39 P 0.324 88-82 302150 40 E 0.298 82-76
    • DRAWING NUMBER M-75 303010 1 P 0.318 88-82 303015 1A R 0. 110 <65 303017 1B N 0.200 <65 303020 2 T 0.343 0.318 88-82 303160 16 P 0.353 >88 303165 16A R 0.161 <65 303167 16B N 0.250 <65 303220 22 P- 0.271 0.366 >88 303230 23 T 0.318 0.463 >88 303235 23A P 0.344 >88 303240 24 E 0.211 0.372 >88
    • DRAWING NUMBER M>>88A 304420 2 E 0.160 0. 160 76-70 304425 2A P 0.170 0. 150 70-65 304430 3 V NE 304435 3A P 0. 160 0. 140 <65 304440 4 E 0.160 0. 180 88>>82 304450 5 P 0. 250 >88 304460 6 V NE 304560 16 E 0.283 >88 304950 55 E 0. 150 0.160 76-70 304955 55A P 0.160 0.160 76-70 304960 56 E 0.280 >88 304970 57 P 0.150 0.160 76-70 304980 58 E 0.300 >88 304990 59 V NE 305000 60 P 0. 170 0.250 >88 305010 61 V NE 305020 62 P 0.170 0.220 >88 Table 1

k*

\,

-1

\

el.

P 1

~I 4

Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL 305090 69 E 0.261 88-82

    • DRAWING NUMBER M-48 320370 37 E 0. 265 >88 320390 39 P 0.287 >88 320400 40 E 0.285 >88
    • DRAWING NUMBER M-49 323420 42 P 0.266 0.269 >88
    • DRAWING NUMBER M-47 327070 7 E 0.296 0.321 88-82 327080 8 P 0.352 >88 327180 18 T 0.330 >88'88 327190 19 P 0.278 327200 20 E . 0.287 >88 327250 25 E 0. 314 88-82 327500 50 E 0.288 >88 327510 51 P 0. 292 >88 327570 57 E 0.348 >88
    • DRAWING NUMBER M-46B 328115 11A R 0. 311 >88 328125 12A R 0.352 >88 328130 13 P 0.420 >88
    • DRAWING NUMBER M-46A 329230 53 E 0.362 0.352 82-76
  • " DRAWING NUMBER M-88D 385010 1 E 0.280 >88 385080 8 P 0.262 88-82 385100 10 P 0.288 >88 385260 26 E 0.275 >88 385290 29 P 0.286 >88 385420 42 E 0.289 >88 385470 47 P 0.273 >88 49 P '85490 0.255 88-82 385660 66 E 0.271 >88 385680 68 P 0.272 >88 385800 80 L 0.308 <65
    • DRAWING NUMBER M-81 390060 6 R 0.653 0. 614 76-70
    • DRAWING NUMBER M-94 395010 1 P 0.277 >88 395030 3 . P 0.301 >88 395040 4 "

E 0.267 0.270 >88 395100 10 E 0;242 0.277 >88 Table 1

4f Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN.'ERCENT NUMBER NO. READING READING NOMINAL 395180 18 E 0. 290 >88 395190 19 P 0.280 >88

.395210 2r. P' 0.306 >88 395230 23 0.298 >88 395240 24 E 0.293 88-82 .

395270 27 P 0.305 >88 395290 29 P 0.288 >88

'95360 36 E 0.231 0.262 88-82 395400 40 E 0.281 >88 395440 44 E 0.259 88-82 395450 45 P 0.280 >88 395470 47 P 0.302 >88 395490 49 P 0.'300 >88 395500 50 E 0.309 >88

    • DRAWING NUMBER NA 400001 NA E 0. 759 >88 400002 NA E 0.672 >88 400003 NA R 0.381 >88 400004 NA R 0.359 >88 400005 NA P 0.397 >88 400006 NA E 0.427 >88 400007 NA E 0.277 >88 400008 NA 'P 0.265 >88 400009 NA L 0.234 >88 400010 NA E 0.252 >88 400011 NA E 0.240 >88 400012 NA P 0.160 >88 400013 NA T 0.200 >88 400014 NA P 0.102 <65 400015 NA P 0.200 >88 400016 NA P 0.195 >88 400017 NA E 0.190 >88 400018 NA P 0.200 >88 400019 NA E 0.230 >88 400020 NA P 0.195 >88 400021 NA T 0.250 >88 400023 NA P 0.180 >88 400024 NA P 0.180 >88 400025 NA E 0.230 >88
    • DRAWING NUMBER M-89A 400026 14 N 0. 500 >88 400027 15 P 0.'225 >88 400028 16 T 0.270 >88 400029 17 P 0.218 >88 400030 18 T 0.350 >88 40003'1 19 P 0.210 >88 .

400032 20 P 0.179 >88 400033 28 P 0.210 >88 Table 1

Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL 400034 29 0.270 >88 400035 30 0.210 >88

    • DRAWING NUMBER M-89B 400036 8A P 0. 190 88-82 400037 9 T 0.300 >88 400038 11 P 0.220 >88 400039 12 P 0.190 88-82 400040 24 P 0.170 >88
    • DRAWING NUMBER M-89C 400041= 26 T 0.300 >88 400042 27 P 0.180 88-82 400043 28 E 0.300 >88 400044 29 P 0.190 88-82 400045 30 T 0.290 >88 400046 31 P 0.170 82-76
  • " DRAWING NUMBER NA 400047 1 P 0.281 76-70 400048 2 P 0.261 76-70 400049 3 P 0.280 76-70 400050 4 P 0.274 76-70 5 '00051 P 0.259 70-65 400052 6 P 0.267 76-70 400053 7 P 0.250 70-65 400054 8 P -0.253 70-65 400055 D P 0.274 76-70 400056 C 0.234 (65 400057 B 0.247 70-65 400058 A 0.230 <65
    • DRAWING NUMBER M-SW 400059 1 E 0.360 >88 400060 2 E 0.361 >88 400061 3 E 0.350 >88 400062 4 E 0. 359 >88 400063 5 P 0.337 >88 400064 6 P 0. 342 >88 400065 7 P 0. 332 >88 400066 8 P 0. 321 88-82 400067 9 E 0.346 >88 400068 10 E 0.341 >88 400069 11 E 0.365 >88 400070. 12 E 0.355 >88 400071 13 P 0.312 88-82 400072 14 P 0.331 >88.

400073 15 P 0.353 >88 400074'00075 16 P 0.346 >88 17 P 0.322 88-82 Table 1

I Page No.

05/15/90

SUMMARY

COMP TYPE 1989 MIN. 1990 MIN. PERCENT NUMBER NO. READING READING NOMINAL 400076 18 T 0.468 >88 400077 19 P 0.325 88-82 400078 20 T 0.425 >88 400079 21 P 0.331 >88 400080 22 P 0.327 88-82 400081 23 P 0.335 >88 400082 24 T 0.458 >88 400083 25 P 0.330 88-82 400084 26 T 0.425 >88 400085 27 P 0.337 >88 Abbreviation Component Type D= Downcomer E= Nozzle P- Pipe R= Reducer T= Tee Table l

kgb I

l

GINNA NUCLEAR POWER STATION Inservice Inspection Report 1990 1999 Interval, First Outage 1990 Attachment III Miscellaneous NDE Examination Summary Report This section consist of all examinations performed as a "service" by Materials Engineering and Inspection Services. The documented results of the below listed examinations have been submitted to the requesting individual and/or department for proper processing. The results of all examinations listed below in this "Mis'cellaneous" Section are acceptable unless otherwise specified.

The following examinations were performed under the Maintenance Inservice Inspection Program (MISIP).

A. Visual Examinations:

1. Reactor Coolant Pump Motor Lift Sling.
2. Reactor Vessel Head Lift Rig.
3. Reactor Vessel Internals Lift Rig.
4. Steam Generator "A" 8c "B"- Tubelane Blocking Device Tack Welds.

B ~Ma netic Particle Examinations:

1. Containment Crane Hooks 7 Hooks Total.
2. Reactor Head Chain Hoist Hooks 3 Hooks Total.
3. Forklift Forks - 11 Forklift Trucks Total.
4. Pallet Cart Forks "A"11 Pallet Carts Total.
5. Steam Generators 4, "B" Secondary Manway Covers.
6. Steam Generator "B" ¹4 and ¹6 Wedge Port Covers.

C. Visual and Liciuid Penetrant Examinations:

1. Steam Generator Nozzle Dams 10 Dams Total.

D. Ultrasonic Examinations:

1. Steam Generator "B" - ¹4 and ¹6 Wedge Port Bolts.

E. Visual and ~Ma netic Particle "A"

Examinations:

"B"

1. Steam Generators and Handhole Covers North and South.

t f

P. Visual ~Ma netic Particle and Ultrasonic Examinations:

1. Steam Generators "A" and "B" Secondary Manway Bolts.
2. Steam Generators "A" and "B" Handhole Cover Bolts North and South.
3. Steam Generator "A" - Outlet Nuts and Studs.
4. Steam Generator "B" Inlet Nuts and Studs.
5. Steam Generator "B" Outlet Nuts and Studs.

~urb'ne Com o ants:

The following examinations were performed on Turbine Components.

Note: Respectable Examination results are reported to the Turbine Department for disposition and corrective action as required.

A. Visual Examinations:

1. Inner Cylinder (¹2) - Stationary Blade Rings Governor End, Stages 8, 9, 10 and 11.

B. Liciuid Penetrant Examinations:

1. L.P. Turbine ¹3 Bearing'abbitt Surface.
2. Valve Stem Seat Main Steam Stop Valve..
3. Stellite Seats ¹2 and ¹4 Control Valves.
4. Outer Diaphragm Top Outside Welds.

II, /

Indication. Bottom Inside Welds.

5. Outer Diaphragm Re 'ectable -Inside Welds; Vertical Weld ¹3, 4 1/2" Linear Thru Wall Indication; Welds ¹ 7 &, 8, 22 Cold Lap Indications.

6 ~ Inner Diaphragm Top Outside Welds.

7. Inner Diaphragm Bottom Inside Welds.
8. "C" L.P. Rotor Stellite Ends.

Re 'ectable Blade W7G at Governor End Stage 9 contained Linear Indication 1/4" Long at Blade Edge.

9. "1" LE P. Rotor Outer Diaphragms crossover Pipe.

C. ~Ma netic Particle Examinations:

1. L.P. Turbine Inner Cylinder-Blade Rings &, Flow Dividers, I

21 Linear Indications at Inner Edge of Blades; Upper Blade Ring 4th Stage Contained 9 Linear Indications on Inner Edge of Blades; Lower Blade Ring 2nd Stage Contained 4 Linear Indications on Inner Edge of Blades; Upper Blade Ring 2nd Stage contained 9 Linear Indications on Inner Edge of Blade; 3rd Stage Contained 2 Linear Indications on Inner Edge of Blade and Between the 3rd and 4th Stages had 1 Linear Indication on Base Surface; Lower Blade Ring 4th Stage Contained 45 Linear Indications on Inner Edge of Blades.

C~

'K tl l

A l

2 ~ ¹2 Inner Cylinder Governor End Stages.

Weld-Steam Undercut on Base Side.

a

3. Upper Inner Cylinder Steam Seals, Control Valve Muffler and Baskets.

II Indications on Inner Edge, of Blades; ¹1 Upper Inner Cylinder (other side) Contained 12 Indications on Inner Edge of Blades.

4. Inner, Crossover Diaphragm.
5. Outer Crossover Diaphragm.
6. "C" L.P. Rotor - End Shafts.

7 ~

"C" L.P. Rotor Generator End - Stages 1 11.

8. "C" L.P. Rotor Generator End Stages 1 11.

D. Ultra sonic Examinations:

1 ~ ¹5 Bearing Top &, Bottom Halves Babbitt, Bonding.

2 ~ Inner 8L Outer Shell Dowel Studs 14 Studs Total.

3 ~ Inner &, Outer Shell Studs 92 Studs Total.

4e Control Valve Studs 52 Studs Total.

5. Stop Valve Studs 30 Studs Total.
6. Crossover Hi Hat Studs 52 Studs Total.

7 ~ Inner Cylinder Shell Studs 55 Studs Total.

8. H.P.'oupling Studs 20 Studs Total.
9. Stop Valve Pilot &, Mummy Studs 24 Studs Total.
10. Outer Cylinder Shell Studs 52 Studs Total.

11 Jack Shaft Thrust Studs 30 Studs Total.

'2 Cross Pipe Vertical Joint 44 Studs Total.

'3 Crossover Pipe Diaphragm 52 Bolts Total.

'4.

Crossover Studs 5 Studs Total.

15. Inner Cylinder 17 Studs Total.
16. Control Valve Tension Bolts 2 Bolts Total.

17 Blade Ring 4 Studs Total.

'8.

Stud 688J343-19 25 Studs Total.

19. Inner Shell Studs 682J249-23 2 Studs Total.
20. Inner Shell Studs 682J343-21 4 Studs Total.

21 Inner Shell Studs 682J343-16 4 Studs Total.

'2 Upper Studs 885J343-19 25 Studs Total.

'3 Inner Shell Studs -'82J342-15 12 Studs Total.

'4

~ Miscellaneous Turbine Studs 120 Studs Total.

E. Liciuid Penetrant and Ultrasonic Examinations:

1. Upper Babbitt,
2. Lower Babbitt.

II~

~Wor $ 4eceests ~WR~P The following examinations were performed in support of Engineering Work Requests (EWR's).

A. Visual Examinations:

1. 1/2" Valves 1032-1 &, 1032-2, Cleanliness-EWR 4613.

the Joint "Prep" Joint, g3. Burr removed and verified by

'luor 20" Daniel QC personnel Accepted.

2. Service Water Header, Cleanliness-EWR 4930.

B. Radio ra hic Examinations:

1. Containment Penetration 2 Welds EWR 4998 '

and Linear Indications. Repaired, Re-examined and Accepted.

C. Visual and Ultrasonic Examinations:

1. Heater Drain Tank Pump Barrels "A" 8L "B" EWR 5053.

The following examinations were performed in support of Maintenance Work Orders (MWO's).

A. Visual Examinations:

1. CV Equipment Hatch Geneva Latch Plug Welds.
2. CV Floor Grating Tack Welds.
3. Pressurizer Safety Line Nuts for Valves 434 &, 435 Replacements (48 nuts &. 93 studs accepted).

Q Contained Axial Cracks in Hex Head, 2 Nuts Contained Thread Damage that Prevented Engagement on Stud.

B. Ultrasonic Thickness Examinations:

1. H.P. Turbine Drain Lines Pipe &, Fittings Wall Thickness.

C. Visual and L'iciuid Penetrant Examinations:

1. 3/4" Nitrogen Supply to AOV-846, 8 Socket Welds.
2. Charging Pump "A" - 3/4" Valve 281C &, Piping - 8 Welds.
3. Safety Injection Pump "B" 3/4" Nipple to Elbow Weld.
4. MSIV 3516 Lug & Nut Locking Weld.

1 .e a',q

5. MS Non-return Check Valve 3518B Disc Stop Welds.

Re-Examined after Repairs-Acceptable.

6. MS Non-return Check Valve 3519A Disc Stop Welds.

Re-Examined after Repairs-Acceptable.

7. "A" &, "B" Service Water Pressure Gage Header -Pipe Coupling Welds. (1" pipe to coupling to 20" pipe) 8 ~ Charging Pump "A", Valve 285 to Pipe Weld.
9. Charging Pump "B", Valve 284 to Pipe Weld.

"C",

10. Charging Weld Pump

/"

Valve 283 to Pipe Weld.

Centerline. Reexamined after repairs ,

/

accepted.

D.

k.

The

~

Liciuid Penetrant and ~Ma netic Particle Examinations:

1 ~

"A" Preseparator 16" Diameter Pipe Replacement 3 Welds.

miscellaneous work.

A.

e following examinations were performed in support of Visual Examinations on Welds:

1, Astregal Plate Welds Fire Door ¹ 23.

2. Skin Repair Fire Door ¹ F-500.
3. Heater Drain Tank at Valve 3098, 1/2" Socket Welds 3 Welds.
4. Freeze Plugs in Nitrogen Supply Lines.
5. "B" Reactor Coolant Pump Insulation Support Welds.

6, Steam Generator Blowdown Socket Welds.

7. DI System - Valve 8419 Valve Cap.
8. Steam Generator Blowdown Valve 5701, 2 Welds.
9. "B" Steam Extraction Line 5 Welds.
10. Check Valve 4023 Tack Welds.
11. Personnel Hatch Outer Door Geneva Latch Plate Plug Weld.
12. Steam Generator Blowdown Valve 5735 8 Socket Welds.
13. Equipment Hatch Rollup Door Channel to Plate, Angle and Lug ~
14. "B" CCW Pump Motor Stand to Base Plate.

B. Visual Examinations on Com onents:

1. Class 2 Valve Upgrade for Henze Valve Nuts.
2. Valve Stem Feedwater Valve 4269.
3. Steam Generator Primary Manway Washers 201 Washers Accepted.

Re 'ectable 2 Washers Contained Machine Cuts on ID Surface.

s t4r .

Ci P'1 yr

4, Steam Support S-4, Re-exam for NCRG89-365.

5. Service Water Headers Screen House Min Wall & Surface Condition.
6. Service Water 20" Header Pipe Downstream of Support 7

'ain

~

SWU-616.

Fire Doors ¹37, ¹46, ¹27, ¹26, ¹79, ¹61 and ¹62 Fillet Welds.

8. Service Water Screen House Surface Condition Downstream from Valve 4606'.

/ "

/

Wall Thickness Resulted in Identifying Wall to be 0.355" Thick. Remaining Wall Thickness is 0.305". Wall Loss at This Area 14X.

9 ~ Service Water Screen House Surface Condition Downstream from Support SW-620.

Re ectable Random Pitting and Undercut Around Entire Circumference. Pitting 8 to 17X of Wall Thickness ( 1/64" to 1/16" Deep).

10 "A" Service Water Pump 2 Rigid Restraints.

C. Liciuid Penetrant Examinations on Com onents:

1. Ten Inch (10") SI Line, 2" Weld-0-Let " to Pipe.'

/

90-102 Generated. Defects were Repaired by Blending, Re-.

examined -Acceptable.

2. Freeze Plugs for Leakage Examination on Pipe 2 Areas.
3. Main Feedwater Pump Shaft &, Impeller.
4. Feedwater Valve 4272 Seat Examination.
5. Low Pressure Steam Extraction Bellows Welds.

6,. Valve 4270 - Stem, Seats, Plug &, Gage.

7. Valve ¹ 390 Filter Vent Socket Weld.
8. CVCS Pipe to Valve ¹ 390.
9. Hanging Scaffolds, Al, A2, Bl, B2 & B3, 25 Welds Total.

Re 'ectable -Linear Indications in Bl &" B2. These welds are to be repaired and reexamined before the 1991 AI&0,

10. Bolts from Check Valves 870A, 870B, 889A & 889B.

D. ~Ma netic Particle Examinations on Com onents:

1 ~ Auxiliary Feedwater Valve 4017 Seat Area.

NCR 90-96 was Generated. Defects were Repaired and Re-examined -Acceptable.

2. L.P. Steam Extraction to 2A Heater Bellows.
3. Steam Extraction Pipe to Elbow Welds.
4. Steam Extraction to 5A &, 5B Heaters Reducer Welds (2).
5. Blowdown to Blown Tank Component 80 Pad Weld.

E. Ultrasonic Examinations on Com onents:

l. Auxiliary Feedwater-Three Supports-Verify Bolt Lengths.
2. 1A &. 1B Diesel Generators-Ductwork-Verify Bolt Lengths.
3. Spent Fuel Pit "A" - Verify Bolt Support AFW-600, Verify Bolt Lengths.

Lengths'.

I ~

4g

-S A

Pl t4 rr t

jg I

5. Support SWU-623, Verify Bolt Lengths.

6, Service Water 14" Diameter Pipe Wall Thickness.

7. Support SWU-625, Verify Bolt Lengths.
8. S/G "A", Swirl Vane Wrapper- Wrapper Thickness.

Generated. Fabricated and Installed 7 Impingement Plates on Severely Eroded Areas. Use-As-Is on Feedwater Tee Erosion. A Monitoring Program Initiated for the Feedwater Tee 8c Steam Generator Wrapper Erosion not Repaired in. the 7 Areas Above.

9. S/G "B", Swirl Vane Wrapper- Wrapper Thickness.

Re 'ectable Wrapper Thickness Eroding, NCR 90-124 Generated, Action Taken was Incorporated into Item 48 Above.

10. Sampling Line at AOV 5736 Wall Thickness.
11. Service Water Support SWU-631, SWU-632, SWU-633 and SWU-634, Verify Bolt Lengths.
12. Service Water Support SWU-568, Verify Bolt Lengths.

F. Visual and Liciuid Penetrant Examinations on Com onent.s:

1. RHR System By Valve 687B - Sock-o-let Weld.
2. Service Water Header Valve 4799 2 Welds, Coupling, and "Prep" Areas.

G. Visual and ~Ma netic Particle Examinations on Com onents:

l. "A" S/G - Swirl Vane Wrapper Patches.

Generated, Action Taken was Incorporated into Items 48 & 9 in Paragraph E Above.

2. Main Steam System Valve 3411 Flange Seal Area.

H. Visual ~Ma netic Particle F. Ultrasonic Examinat.iona on Com onents:

1. Retaining Block Studs Baseline for Valves 870A, 870B, 880A and 880B.

~

1. Pipes and Elbows in the Min-Wall (Wall Thickness) Program.
2. "B" Reactor Coolant Pump Insulation Support Bushings.
1. Service Water Elbow Downstream of Valve 9633B.
2. Standby Auxiliary Feedwater -Pipe by Support SWO-508 0.207" Thickness, 1"
1. 3/4," Chemical Feed Line to "A" S/G Feedwater.

Angle Iron. Missing Nut on U-Bolt.

b

/fan