CATEGORY 1 REGULA'2. RY INFORMATION DISTRIBUTI SYSTEM (RIDS)
ACCESSION NBR:9904200295 DOC.DATE: 99/03/31 NOTARIZED: NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G
AUTH.NAME.
AUTHOR AFFILIATION WALDEN,J.V.
Rochester Gas 5 Electric Corp.
WIDAY,J.A.
Rochester Gas
& Electric Corp.
RECIP.NAME RECIPIENT AFFILIATION DOCKET I 05000244 VISSING,G.S.
SUBJECT:
Monthly operating rept for Mar 1999 for Ginna Station. With 990409 ltr.
DISTRIBUTION CODE: IE24D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: Monthly Operating Report (per Tech Specs)
NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72)
A T
05000244 RECIPIENT ID CODE/NAME LPD1-1 PD INTERNAL: AEOD/SPD/RRAB OC/DBA/PAD EXTERNAL: LMITCO MARSHALL NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 NOAC 1
1 RECIPIENT COPIES ID CODE/NAME LTTR ENCL VISSING,G.
1 1
ILE CENTER 0
1 1
1 1
0 i> iIIIIi)iI>t'I i ',Ii I
I
- Ilail, II i,<
'OTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTETH TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)
ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 9
ENCL 9
4
'1 t1 '.
ANO II ROCHESTER GAS ANDELECTRICCORPORATION 89EASTAVENIJE, ROCHESTER, N.Y. 14649-0001 AREA CODE 716-546-2700 April 9, 1999 US Nuclear Regulatory Commission Document Control Desk Attn:
Guy S. Vissing Project Directorate l-1 Washington, DC 20555
Subject:
Monthly Report for March, 1999 Operating Status Information R.E. Ginna Nuclear Power Plant Docket No. 50-244
Dear Mr. Vissing:
Pursuant to Ginna Improved Technical Specifications Section 5.6.4, attached is the monthly operating status report for Ginna Station for the month of March, 1999.
Very truly yours, ad o eph A. Wida Plant Manager xc:
U.S. Nuclear Regulatory Commission Mr. Guy S. Vissing (Mail Stop 14B2)
Project Directorate I-1 Washington, D.C. 20555 U.S. Nuclear Regulatory Commission Region I
475 Allendale Road King of Prussia, PA 19406 U.S. NRC Ginna Senior Resident Inspector Attachments 9904200295 990331 PDR ADGCK 05000244 R
'!00034
OPERATING DATAREPORT COMPLETED BY:
50-244 A ril 9, 1999 John V. Walden TELEPHONE (716) 771-3588 OPERATING STATUS 480
- 1. Unit Name:
R.E. GINNANUCLEAR POWER PLANT
- 2. Reporting Period:
March, 1999 3.
Design Electric Rating (Net MWe):
470 4.
Maximum Dependable Capacity (Net MWe):
, Notes:
This Month Yr.-to-Date Cumulative**
- 5. Number of hours Reactor Was Critical
- 6. Hours Generator On-line
- 7. Unit Reserve Shutdown Hours
- 8. Net Electrical Energy Generated (MWH) 9.2 8.9 0.0 2219.0 1425.2 1424.9 0.0 653306.0 208144.3 205123.6 85 92504386.4
- CUMULATIVETOTALCOMMENCING NOVEMBER 8, 1969
DOCKET NO: 50-244 UNIT NAME: R.E. GINNA NUCLEAR POWER PLANT COMPLETED BY:
John V. Walden UNIT SHUTDOWN REPORTING PERIOD:
March 1999 (Month/Year)
NO.
DATE 1
3/1/99 TYPE F: FORCED S: SCHEDULED DURATION (HOURS) 735.1 REASON"'ETHOD OF SHUTTING DOWN"'AUSE/CORRECTIVE ACTIONS COMMENTS
SUMMARY
The unit was in shutdown for refueling and maintenance on March 1, 1999.
(1) Reason A - Equipment Failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory Restriction E - Operator Training/License Examination F - Administrative G - Operational Error (Explain)
H - Other (Explain)
(2) Method 1 - Manual 2 - Manual Trip/Scram 3 - Automatic Trip/Scram 4 - Continuation 5 - Other (Explain)
0 1
t