Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000250/LER-1989-005-01, :on 890215,auxiliary Feedwater Flow Automatically Initiated Following Attempt to Start Steam Generator Feedwater Pump.Caused by Wiring Error on Starting Circuit Relay.Wiring Error Corrected + (15:28:07, 7 January 2025)
- TAC:66339 + (15:28:08, 7 January 2025)
- ML17347B019 + (15:28:10, 7 January 2025)
- 05000251/LER-1989-001-01, :on 890209,emergency Diesel Generator Inoperable W/Rhr 4B out-of-svc.Caused by Miscommunication Between Operations Personnel.Procedure O-OSP-023.1 Revised to Require Operability of Required Equipment + (15:28:11, 7 January 2025)
- ML17347B017 + (15:28:12, 7 January 2025)
- ML17347B014 + (15:28:13, 7 January 2025)
- ML17347B013 + (15:28:14, 7 January 2025)
- IR 05000250/1989004 + (15:28:16, 7 January 2025)
- ML17347B009 + (15:28:18, 7 January 2025)
- ML17347B008 + (15:28:19, 7 January 2025)
- ML17347B006 + (15:28:20, 7 January 2025)
- ML17347B007 + (15:28:20, 7 January 2025)
- IR 05000250/1989001 + (15:28:23, 7 January 2025)
- ML17347B003 + (15:28:25, 7 January 2025)
- ML17347B002 + (15:28:26, 7 January 2025)
- ML17347A998 + (15:28:28, 7 January 2025)
- ML17347A995 + (15:28:28, 7 January 2025)
- ML17347A994 + (15:28:30, 7 January 2025)
- IR 05000250/1989005 + (15:28:31, 7 January 2025)
- ML17347A991 + (15:28:33, 7 January 2025)
- ML17347A990 + (15:28:34, 7 January 2025)
- ML17347A988 + (15:28:35, 7 January 2025)
- ML17347A983 + (15:28:36, 7 January 2025)
- ML17347A982 + (15:28:37, 7 January 2025)
- ML17347A981 + (15:28:41, 7 January 2025)
- RBG-47809, Request for Due Date Extension for License Renewal Application - Response to NRC Request for Additional Information - Set 3 + (15:28:42, 7 January 2025)
- ML17347A978 + (15:28:43, 7 January 2025)
- ML17347A977 + (15:28:44, 7 January 2025)
- 05000250/LER-1989-003-01, :on 890124,control Room Ventilation Sys Shift to Recirculation Mode During Channel Check Occurred.Caused by Flaw in Design of Radiation Monitor Circuit Module.Work Instruction Revised + (15:28:46, 7 January 2025)
- 05000250/LER-1989-001, :on 890110,emergency Diesel Generator (EDG) B & Intake Cooling Water Pump 3A Out of Svc During Same Time. Caused by Operability Test Being Performed.Edg Returned to Svc on 890110 & Pump Checked + (15:28:49, 7 January 2025)
- IR 05000250/1988040 + (15:28:57, 7 January 2025)
- ML17347A972 + (15:28:59, 7 January 2025)
- ML17347A971 + (15:29:00, 7 January 2025)
- ML17347A970 + (15:29:04, 7 January 2025)
- 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced + (15:29:07, 7 January 2025)
- ML17347A967 + (15:29:09, 7 January 2025)
- ML17347A966 + (15:29:10, 7 January 2025)
- ML17347A965 + (15:29:12, 7 January 2025)
- IR 05000250/1988034 + (15:29:13, 7 January 2025)
- ML17347A963 + (15:29:15, 7 January 2025)
- ML17347A958 + (15:29:16, 7 January 2025)
- ML17347A956 + (15:29:17, 7 January 2025)
- ML17347A954 + (15:29:17, 7 January 2025)
- ML17347A951 + (15:29:18, 7 January 2025)
- ML17347A950 + (15:29:20, 7 January 2025)
- ML17347A949 + (15:29:21, 7 January 2025)
- ML17347A948 + (15:29:22, 7 January 2025)
- PNO-II-89-008A, on 890116,during Plant Shutdown Required by Tech Spec Update Licensee Discovered Incore Flux Mapping Thimble Tubes Cracked & Leaking.Thimble Tube Conduit Cut Out of Seal Table & Replaced.Unit to Be Placed on Line 890202 + (15:29:24, 7 January 2025)
- ML17347A946 + (15:29:25, 7 January 2025)
- IR 05000250/1988036 + (15:29:27, 7 January 2025)
- ML17347A943 + (15:29:29, 7 January 2025)