Browse wiki
Jump to navigation
Jump to search
ML17347A969 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +, 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced + and 05000250/LER-1989-002, :on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced +
February 14, 1989 +
2 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
15:29:07, 7 January 2025 +
10 +
February 14, 1989 +
Florida + and Washington +
:on 890116,normal Plant Cooldown Initiated Due to Small Boundary Leak of Rcs.Caused by Transgranular Stress Corrosion Cracking in Mapping Sys Thimble Guide Tube J-12 & J-7.Guide Tubes Involved Repaired or Replaced
+
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.