Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20138P125 + (ML20138P125)
- PNO-V-85-087, on 851215,steam Leak Discovered in Room Where Normal Reactor Coolant Makeup Pump Located.Simultaneously, Auxiliary Bldg Radiation Alarm Received.Leak Isolated to Discharge Piping Weld + (ML20138P126)
- ML20138P127 + (ML20138P127)
- ML20138P129 + (ML20138P129)
- ML20138P131 + (ML20138P131)
- ML20138P132 + (ML20138P132)
- ML20138P133 + (ML20138P133)
- ML20138P135 + (ML20138P135)
- ML20138P136 + (ML20138P136)
- 3F1285-12, Confirms 850125 Notification to Adopt Gpu Approach to Analyzing Natural Circulation Cooldown (Generic Ltr 81-21).TMI Topical Rept on Subj Encl + (ML20138P137)
- ML20138P138 + (ML20138P138)
- ML20138P139 + (ML20138P139)
- ML20138P141 + (ML20138P141)
- 3F1285-04, Monthly Operating Rept for Nov 1985 + (ML20138P142)
- ML20138P143 + (ML20138P143)
- ML20138P144 + (ML20138P144)
- ML20138P145 + (ML20138P145)
- ML20138P146 + (ML20138P146)
- ML20138P147 + (ML20138P147)
- ML20138P148 + (ML20138P148)
- ML20138P149 + (ML20138P149)
- ML20138P150 + (ML20138P150)
- ML20138P151 + (ML20138P151)
- ML20138P152 + (ML20138P152)
- ML20138P153 + (ML20138P153)
- ML20138P154 + (ML20138P154)
- ML20138P155 + (ML20138P155)
- ML20138P157 + (ML20138P157)
- ML20138P159 + (ML20138P159)
- ML20138P161 + (ML20138P161)
- ML20138P162 + (ML20138P162)
- ML20138P164 + (ML20138P164)
- ML20138P165 + (ML20138P165)
- 05000338/LER-1985-020-01, :on 851118,eddy Current Insps of Steam Generator C Identified More than 1% of Sampled Tubes as Defective.Cause Under Investigation by Westinghouse.Tubes Plugged + (ML20138P166)
- ML20138P167 + (ML20138P167)
- ML20138P168 + (ML20138P168)
- 05000029/LER-1985-003-01, :on 851105,discovered That Fuel Assembly B-696I Sustained Fretting Damage on Spacer Grids.On 851106,found That Assembly B-688 Had Failed Fuel Rod & on 851107,found That Assembly A-679 Had Failed Rod + (ML20138P169)
- ML20138P171 + (ML20138P171)
- ML20138P173 + (ML20138P173)
- ML20138P174 + (ML20138P174)
- ML20138P175 + (ML20138P175)
- ML20138P177 + (ML20138P177)
- 05000029/LER-1985-004-01, :on 851206,during Refueling Outage,Valve PR-SV-181 (S/N Bw 07972) Setpoint Exceeded Tolerance.Caused by Setpoint Drift.Setpoint Adjusted & Retested.Overpressure Protection Rept Reviewed + (ML20138P179)
- ML20138P181 + (ML20138P181)
- ML20138P182 + (ML20138P182)
- ML20138P183 + (ML20138P183)
- 05000498/LER-1997-003, :on 970123,potential for Overpressurization of Piping Identified.Caused by Deficiency in Original Design. Thermal Insulation Installed on Lines 3WL-1009 & 3WL-2009 & Lines Have Been Returned to Service + (ML20138P185)
- ML20138P187 + (ML20138P187)
- ML20138P188 + (ML20138P188)
- ML20138P191 + (ML20138P191)
- ML20138P193 + (ML20138P193)