List of results
- ML20086G227 + (ML20086G227)
- ML20086G234 + (ML20086G234)
- ML20086G237 + (ML20086G237)
- ML20086G241 + (ML20086G241)
- ML20086G243 + (ML20086G243)
- 05000298/LER-1991-014, :on 911030,unplanned Actuation of Group 6 Isolation Occurred.Caused by Improper Selection of Uninsulated Metal Clip for Surveillance Testing.Uninsulated Metal Clips Replaced During Refueling Outage + (ML20086G244)
- ML20086G245 + (ML20086G245)
- ML20086G248 + (ML20086G248)
- ML20086G250 + (ML20086G250)
- ML20086G251 + (ML20086G251)
- ML20086G253 + (ML20086G253)
- ML20086G256 + (ML20086G256)
- 05000278/LER-1976-019-03, /03L:on 760117,refuel Interlocks Failed to Prevent More than One Control Rod Withdrawing.Caused by Wiring Error,Two Failed Philco Integrated Circuit Chips & Ground Wire Between Rod Position Probe & Buffer Card + (ML20086G257)
- ML20086G258 + (ML20086G258)
- ML20086G259 + (ML20086G259)
- ML20086G262 + (ML20086G262)
- ML20086G263 + (ML20086G263)
- ML20086G264 + (ML20086G264)
- ML20086G265 + (ML20086G265)
- ML20086G267 + (ML20086G267)
- ML20086G268 + (ML20086G268)
- ML20086G270 + (ML20086G270)
- ML20086G271 + (ML20086G271)
- ML20086G272 + (ML20086G272)
- ML20086G274 + (ML20086G274)
- ML20086G276 + (ML20086G276)
- ML20086G277 + (ML20086G277)
- ML20086G278 + (ML20086G278)
- ML20086G281 + (ML20086G281)
- ML20086G282 + (ML20086G282)
- ML20086G283 + (ML20086G283)
- ML20086G285 + (ML20086G285)
- ML20086G287 + (ML20086G287)
- ML20086G289 + (ML20086G289)
- ML20086G293 + (ML20086G293)
- 05000336/LER-1995-002, :on 950125,confirmed Assumption for Original Design Basis Re Containment Sump Isolation Valves non- Conservative.Caused by Inadequate Engineering Evaluation. Hole Drilled Through Disc Ctr Line + (ML20086G297)
- ML20086G299 + (ML20086G299)
- ML20086G303 + (ML20086G303)
- ML20086G304 + (ML20086G304)
- 05000277/LER-1976-014-01, /01T:on 760303,recombiner Mechanical Compressor 2B Leak Rate Exceeded Allowable Limits.Caused by Numerous Leaks Associated W/Compressor Head O-rings & Valve covers.O-rings Replaced & Valve Covers Lightened + (ML20086G305)
- ML20086G306 + (ML20086G306)
- ML20086G307 + (ML20086G307)
- ML20086G308 + (ML20086G308)
- ML20086G312 + (ML20086G312)
- ML20086G313 + (ML20086G313)
- ML20086G315 + (ML20086G315)
- ML20086G316 + (ML20086G316)
- ML20086G318 + (ML20086G318)
- 05000278/LER-1976-006-01, /01T:on 760111,snubber on Main Steam Line D Inoperable Due to Empty Reservoir.Caused by Leaking fittings,O-rings & Gaskets.All Defective Parts Will Be Replaced + (ML20086G319)
- 05000263/LER-1995-006-01, :on 950610,drain Valve Not Fully re-closed During Surveillance of SJAE OG RM Chamber Rendering Both SJAE RMs Inoperable.Caused by Personnel/Cognitive Error. Training Provided & Procedure Changed + (ML20086G320)
- 05000278/LER-1976-005-01, /01T:on 760111,three Snubbers on Lines RV-71A, RV-71K & RV-71H Inoperable Due to Empty Reservoirs.Caused by Leaking fittings,O-rings & Gaskets.All Defective Parts Will Be Replaced + (ML20086G321)