Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20205A14523 March 1999Core Shroud Insp PlanVT-2
Moisture barrier
EVT-1
ML20151S38531 August 1998Long-Term Program:Semi-Annual ReptSafe Shutdown
Ultimate heat sink
Coatings
Foreign Material Exclusion
Severe Accident Management Guideline
Maintenance Rule Program
Downpower
Operability Assessment
Water hammer
ML20211N68716 September 1997Rev 9 to Procedure 8.I.1.1, Inservice Pump & Valve Testing ProgramSafe Shutdown
High Radiation Area
Ultimate heat sink
Stroke time
Squib
Scram Discharge Volume
Intergranular Stress Corrosion Cracking
Excess Flow Check Valve
Cold shutdown justification
Power Operated Valves
Scaffolding
Grace period
ML20211G23815 September 1997Rev 8 to PNPS-ODCM, Pilgrim Nuclear Power Station OdcmGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
ML20216C06329 August 1997Semi-Annual Long Term Program ScheduleSafe Shutdown
Foreign Material Exclusion
Intergranular Stress Corrosion Cracking
Severe Accident Management Guideline
Downpower
ML20210K3551 July 1997Rev 16 to Procedure 7.8.1, Water Quality LimitsGrab sample
Feedwater Heater
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Fuel cladding
ML20117K66117 July 1996Rev 15 to PNPS Procedure 1.2.2 Administrative OPS Requirements
ML20100J25222 November 1995Rev 7 to Pilgrim Nuclear Power Station OdcmOffsite Dose Calculation Manual
ML20092B5861 September 1995Rev 0 to Third Ten-Yr Interval ISI Plan for Pilgrim Nuclear Power StationHydrostatic
Nondestructive Examination
VT-2
Incorporated by reference
Pressure boundary leak
Backfit
ML20077Q11813 January 1995Owner'S Specification for Reactor Shroud Repair
ML20127N27124 November 1992Rev 4 to Pilgrim Nuclear Power Station Procedure 8.I.1.1, Inservice Pump & Valve Testing ProgramSafe Shutdown
High Radiation Area
Ultimate heat sink
Stroke time
Squib
Local Leak Rate Testing
Scram Discharge Volume
Intergranular Stress Corrosion Cracking
Excess Flow Check Valve
Cold shutdown justification
Power Operated Valves
Scaffolding
Grace period
ML20128M77031 March 1992Amend 92-01 to Second Ten Year ISI ProgramHydrostatic
VT-2
Dissimilar Metal Weld
ML20094P54119 March 1992Rev 23 to Procedure 5.4.6, Primary Containment Venting & Purging Under Emergency Conditions, Revising Coversheet & Attachment 1,Sheet 3 of 5,page 8 of 20
ML20058E52825 October 1990Rev 1 to Procedure 8.I.1.1, Inservice Pump & Valve Testing Program
ML20005F07913 December 1989Rev 0 to Procedure 8.I.1.1, Inservice Pump & Valve Testing Program.Safe Shutdown
High Radiation Area
Ultimate heat sink
Stroke time
Squib
Scram Discharge Volume
Intergranular Stress Corrosion Cracking
Excess Flow Check Valve
Cold shutdown justification
Power Operated Valves
Operability Assessment
ML20247N36131 July 1989Rev 2 to Dcrdr Program PlanPost Accident Monitoring
Probabilistic Risk Assessment
Emergency Lighting
Feedwater Heater
Backfit
Loss of condenser vacuum
ML20245D65521 April 1989Power Ascension Program Resumption Plan
ML20235R34428 December 1988Rev 26 to, Pilgrim Nuclear Power Station Secondary Containment Leak Rate Test
ML20235R46722 December 1988Rev 25 to, Pilgrim Nuclear Power Station Secondary Containment Leak Rate Test
ML20155C01428 September 1988Rev 3 to Appendices to Restart PlanSafe Shutdown
Reactor Vessel Water Level
Loop seal
Packing leak
High Radiation Area
Fire Barrier
Temporary Modification
Emergency Lighting
Missed surveillance
Local Leak Rate Testing
Feedwater Heater
Stress corrosion cracking
Integrated leak rate test
Exemption Request
Fire Protection Program
Fire Watch
Scaffolding
Overspeed trip
Water hammer
ML20155F9047 September 1988Rev 3 to Pilgrim Nuclear Power Station Plant-Specific Technical Guidelines for Emergency Operating ProceduresHydrostatic
Scram Discharge Volume
Earthquake
ML20153H64831 August 1988Ascension ProgramOverspeed trip
ML20235R3809 August 1988Special Post-Startup Training Program to Satisfy Requirements of NUREG-1021,Section ES-109,Parts B.2.e & B.2.f for Reactor Operator Licensed Personnel & Parts D.2.e & D.2.f for Senior Reactor ..
ML20150C02726 May 1988Rev 2 to Vol 2 to Apps to Restart PlanSafe Shutdown
Reactor Vessel Water Level
Packing leak
High Radiation Area
Grab sample
Fire Barrier
Hydrostatic
Temporary Modification
Emergency Lighting
Missed surveillance
Local Leak Rate Testing
Feedwater Heater
Scram Discharge Volume
Stress corrosion cracking
Excess Flow Check Valve
Integrated leak rate test
Exemption Request
Fire Protection Program
Fire Watch
Scaffolding
Overspeed trip
Water hammer
ML20151F9486 April 1988Rev 2 to Emergency Operating Procedure 1.3.4-13, Emergency Operating Procedures Verification Program
ML20151C8116 April 1988Rev 3 to Emergency Operating Procedure 1.3.4-10, Writers Guide for Emergency Operating Procedures
ML20151F9686 April 1988Rev 2 to Emergency Operating Procedure 1.2.4-14, Emergency Operating Procedure Validation Program
ML20151C81528 March 1988Emergency Operating Procedures Training Program Summary Description
ML20153B10614 March 1988Rev 1B to Inservice Testing Program for Pumps & Valves, Pilgrim Nuclear Power StationSafe Shutdown
Stroke time
Squib
Intergranular Stress Corrosion Cracking
Excess Flow Check Valve
Power Operated Valves
Pressure boundary leak
ML20236T21720 November 1987Rev 3 to Pilgrim Nuclear Power Station Plant-Specific Technical Guidelines for Emergency Operating ProceduresHydrostatic
Scram Discharge Volume
Earthquake
ML20236T22420 November 1987Rev 3 to Apps to Pilgrim Nuclear Power Plant-Specific Technical Guidelines
ML20236T23620 November 1987Collection of Plant Operating Procedures Utilized to Develop,Process & Issue Plant-Specific Emergency Operating Procedures
ML20236N77512 November 1987Rev 1 to Procedure 3.M.1-1, Preventive MaintHydrostatic
ML20236F02026 October 1987Rev 1 to Vol 2 of Pilgrim Nuclear Power Station Apps to Restart PlanSafe Shutdown
High Radiation Area
Fire Barrier
Temporary Modification
Emergency Lighting
Missed surveillance
Fire Protection Program
Fire Watch
Water hammer
ML20155F91716 October 1987Rev 1 to Procedure 1.3.4-13, Emergency Operating Procedure Verification Program
ML20155F91115 October 1987Rev 2 to Procedure 1.3.4-10, Writers Guide for Emergency Operating Procedures
ML20235X24615 October 1987Power Ascension ProgramOverspeed trip
ML20195H63422 September 1987Rev 23 to Procedure 8.7.3, Secondary Containment Leak Rate TestFire Barrier
ML20238E8311 September 1987Revised Nuclear Operations Dept Procedures,Including Rev 5 to Procedure 5.7.4.1.1, Post-Accident Sampling Sys,Small Vol Liquid Sample from Jet Pump Flow Sensing Line & Rev 6 to Procedure 5.7.4.1.2, ...Undiluted Liquid Sample..
ML20236G40730 July 1987Vol 1 to Pilgrim Nuclear Power Station Restart Plan. Rev 0 to Vol 2,appendices,encl
ML20236F95328 July 1987Matl Condition Improvement Action PlanBackfit
ML20155F92010 July 1987Rev 0 to Procedure 1.3.4-14, Emergency Operating Procedure Validation Program
ML20204F74316 June 1986Rev 1 to Temporary Procedure Tp 86-85, RHR Intersys Leakage Assessment & Controlled Leakoff
ML20204F73010 June 1986Rev 11 to Procedure 2.3.2.1, Panel Procedures Panel 903 Left
ML20204F74810 June 1986Rev 0 to Temporary Procedure Tp 86-84, RHR Discharge Piping Venting ProcedureTemporary Modification
ML20137M48121 August 1985Rev 1 to Procedure 5.7.5, Estimating Core Damage
ML20138R45019 July 1985Rev 0 to Procedure 1.3.4-10, Writers Guide for Emergency Operating Procedures
ML20128N9346 March 1985Rev 0 to Procedure 5.7.5, Estimating Core Damage
ML20101S71213 December 1984Rev 11 to Procedure 2.1.12, Daily Diesel Generator Surveillance
ML20101S72012 December 1984Rev 15 to Procedure 8.9.1, Manually Start & Load Each Diesel Generator Once Per Month