PNO-I-86-050A, on 860715,plant Taken to Cold Shutdown. Preparations for Tube Plugging of Approx 70 Steam Generator Tubes w/50% or Greater through-wall Indications in Top Inch of Rolled Area of Tubes Continuing

From kanterella
Jump to navigation Jump to search
PNO-I-86-050A:on 860715,plant Taken to Cold Shutdown. Preparations for Tube Plugging of Approx 70 Steam Generator Tubes w/50% or Greater through-wall Indications in Top Inch of Rolled Area of Tubes Continuing
ML20203C859
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 07/16/1986
From: Mccabe, Swetland
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
References
PNO-I-86-050A, PNO-I-86-50A, NUDOCS 8607210089
Download: ML20203C859 (1)


'

~. . , .

DCS No: 50213860711 Dato: July 16, 1986 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-I-86-50A This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verification or evaluation, and is basically all that is known by the Region I staff on this date.

Facility: Conr.ecticut Yankee Atomic Licensee Emergency Classification:

Power Company Notification of Unusual Event Haddam Neck Plant Alert Docket No. 50-213 Site Area Emergency Haddam Neck, Connecticut __ General Emergency X Not Applicable

Subject:

SHUTDOWN GREATER THAN 48 HOURS - UPDATE This updates information on concerns about steam generator (SG) tube cracking in the tubesheet area. Approximately 70 SG tubes have 50*4 or greater through wall indications in the top 1 inch of the rolled area of the tubes. These tubes are to be plugged.

This is based on the licensee's conclusion that such plugging will conservatively maintain the structural integrity of the SGs for the remainder of this fuel cycle.

1 Detailed analyses are planned to determine longer-term actions.

The plant was taken to cold shutdown on July 15. Preparations for tube plugging are ongoing. The licensee now expects the plugging to take from one to two weeks.

The "A" charging pump is now expected to be operational on July 16.

Region I and NRC Licensing are following the licensee's activities.

The State of Connecticut has been inforned.

This information is current as of 10:00 a.m., July 16, 1986.

CONTACT: Swetland McCabe 203-267-2571 488-1231 O!STRIBUTION:

H. St. _ MNBB Phillips E/W Willste Mail: ADM:0MB Chairman Zech E00 NRR 'it~ f#iSS D0T:Trans only PA OIA RES Comm. Bernthal ELD AE00 Comm. Roberts Comm. Asselstine ACRS Air Rights INPO----

SECY SP NSAC----

CA POR Regional of fices __._ TMI Resident Section .__

R1 Resident Of fice __

l Licensee:

(heactor Ocensecs) m0. . ,.9) r

'M