Letter Sequence Acceptance Review |
|---|
EPID:L-2021-NEW-0011, (Approved, Closed) EPID:L-2021-NEW-0012, NIST Center for Neutron Research Test Reactor - Request for Changes to Technical Specifications to Allow Low Power Testing (Approved, Closed) |
|
MONTHYEARML17277B2612017-10-24024 October 2017 Aerotest Radiography and Research Reactor, Request for Additional Information Regarding the Renewal of Facility Operating License No. R-98 Project stage: RAI ML17363A3032017-12-20020 December 2017 Submittal of Response to Request to Supplement the License Renewal Application Project stage: Supplement ML18010A5622018-02-0202 February 2018 Aerotest Radiography and Research Reactor - Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML18054A2022018-02-21021 February 2018 Response to Request for Holding Information from Public Disclosure Project stage: Request ML18066A0802018-02-28028 February 2018 Submittal of Response to Request for Holding Information from Public Disclosure Project stage: Request ML18066A0752018-02-28028 February 2018 Submittal of Response to Request for Holding Information from Public Disclosure Project stage: Request ML18088A7532018-03-29029 March 2018 Draft Request for Additional Information for License Renewal of the Aerotest Radiography and Research Reactor Project stage: Request ML18093A3852018-03-29029 March 2018 Clarification of TS 6.6 Project stage: Request ML18074A1112018-04-0202 April 2018 Request for Withholding Information from Public Disclosure Response to Request to Aerotest Operations, Inc. to Supplement the License Renewal Application Project stage: Withholding Request Acceptance ML18088A7012018-04-24024 April 2018 Request for Additional Information Regarding the Renewal of Facility Operating License No. R-98 Project stage: RAI ML18127A0752018-04-30030 April 2018 Elimination of Technical Specification 6.6 Project stage: Request ML18127B7032018-06-0808 June 2018 Review of the Restart Plan for the Aerotest Radiography and Research Reactor Project stage: Approval ML18201A1972018-07-17017 July 2018 Request for Additional Time Project stage: Request ML18198A4512018-07-23023 July 2018 Response to Request for Extension of Time to Respond to Request for Additional Information Regarding the Renewal of Facility Operating License No. R-98 Project stage: RAI ML18257A0752018-09-11011 September 2018 Request for Additional Time Beyond the Deadline to Answer Questions Project stage: Request ML18260A0452018-09-18018 September 2018 Response to Second Request for Extension of Time to Respond to Request for Additional Information Regarding the Renewal of Facility Operating License No. R-98 Project stage: RAI ML18277A2962018-10-15015 October 2018 Request for Additional Information Regarding the Operator Requalification Program for the Aerotest Radiography and Research Reactor Project stage: RAI ML18303A2912018-10-24024 October 2018 Aerotest Radiography and Research Reactor Response to RAI-ORP-7 Project stage: Request ML19015A3322019-01-25025 January 2019 Requests for Renewal of Facility Operating License No. R-98, Review of the Restart Plan, and Amendment to Technical Specification 6.6 for the Aerotest Radiography and Research Reactor Project stage: Approval ML21272A3762021-09-29029 September 2021 Kairos Power, LLC - Submittal of the Preliminary Safety Analysis Report for the Kairos Power Fluoride Salt-Cooled, High Temperature Non-Power Reactor (Hermes) Project stage: Request ML21306A1322021-10-31031 October 2021 Kairos Power LLC Submittal of the Environmental Report for the Kairos Power Fluoride Salt-Cooled, High Temperature Non-Power Reactor (Hermes) Project stage: Request ML21319A3542021-11-29029 November 2021 Acceptance of the Hermes Non-Power Test Reactor Construction Permit Application for Kairos Power LLC Project stage: Acceptance Review ML22024A4922022-01-10010 January 2022 Hermes CP RAI - Preliminary Questions on the Hermes PSAR, Email 1 Project stage: Request ML22028A0022022-02-0202 February 2022 Kairos Hermes Environmental Audit Plan Project stage: Other ML22041A3372022-02-0303 February 2022 Kairos Power LLC, Transmittal of Responses-to NRC Questions 2.3-1 and 2.3-2 on the Hermes Preliminary Safety Analysis Report Project stage: Request ML21364A0132022-02-0808 February 2022 Kairos Power LLC - Application for Construction Permit for Hermes Test Reactor Project stage: Other ML22040A3362022-02-0909 February 2022 Kairos Power LLC, Submittal of Response to NRC Questions 2.5-1, 2.5-2, 2.5-3, and 2.5-4 for PSAR Section 2.5 on Hermes Construction Permit Application Project stage: Request ML22040A3382022-02-0909 February 2022 Kairos Power LLC, Response to NRC Questions 2.5-1, 2.5-2, 2.5-3, and 2.5-4 for PSAR Section 2.5 on Hermes Construction Permit Application Project stage: Other ML21204A0392022-02-15015 February 2022 Federal Register Notice of Intent to Conduct Scoping and Prepare an EIS - Kairos Hermes CP Review Project stage: Request ML22039A2262022-02-17017 February 2022 Audit Plan for the Kairos Hermes Preliminary Safety Analysis Report (PSAR) Section 6.3 Decay Heat Removal System - February 2022 Project stage: Other ML21326A0592022-02-18018 February 2022 Kairos Hermes CP Review - Notice of Intent to Conduct Scoping Process and Prepare an Environmental Impact Statement Project stage: Other ML22091A0002022-03-23023 March 2022 Kairos Hermes Scoping Meeting Transcript Project stage: Request ML22089A1662022-04-0808 April 2022 Kairos Power LLC - Hermes Construction Permit Preliminary Safety Analysis Report I&C Repor (Chapter 7) Audit Plan (Cac/Epid No. 000955/05007513/L-2021-NEW-0011) Project stage: Other ML22110A0182022-05-0505 May 2022 Kairos Power LLC, Summary of March 23, 2022, Public Outreach Meeting on the Proposed Kairos Hermes Test Reactor with Designated Period for Receipt of Environmental Scoping Comments Project stage: Request ML22143B0162022-05-27027 May 2022 Audit Plan for Hermes Site Characteristics PSAR Chapter 2 Project stage: Other ML22230D0762022-08-0505 August 2022 Final RCI 349 on Salt Purity in the Chemistry Control System and the Inert Gas System Project stage: Other ML22227A1802022-08-0808 August 2022 Final RAI 348 on Shutdown Rod Reliability Project stage: RAI ML22329A0112022-11-16016 November 2022 Deis Public Meeting Transcript for Kairos Hermes Construction Permit Application Project stage: Meeting ML22311A5532022-11-16016 November 2022 Kairos Hermes NRC Staff Presentation at Nov 16 Public Meeting on the Draft Environmental Impact Statement for the Construction Permit for the Kairos Hermes Test Reactor Project stage: Request ML23031A1602023-03-21021 March 2023 Summary of Public Meeting for the Draft Environmental Impact Statement for the Kairos Hermes Test Reactor Construction Permit Application ML23031A1652023-03-21021 March 2023 Kairos Attendance List Project stage: Request ML23158A2682023-06-13013 June 2023 Safety Evaluation for Hermes Construction Permit Application Project stage: Approval ML23158A2662023-06-13013 June 2023 Transmittal of Safety Evaluation for Hermes Construction Permit Application Project stage: Approval ML24284A1712023-07-14014 July 2023 NRC-002B - Kairos Power LLC, Construction Permit Application - General Information (July 14, 2023) Project stage: Other ML23195A1252023-07-14014 July 2023 Enclosure 3: Environmental Report H2-ER-0000001, Rev. 0 Project stage: Request ML23181A1072023-07-18018 July 2023 Summary of August 25 and 30 2022 Public Meetings on the Kairos Hermes Preliminary Safety Analysis Report Project stage: Meeting ML23237B4652023-09-11011 September 2023 FRN: General Notice. Acceptance for Docketing of the Kairos Power LLC Hermes 2 Test Reactor Construction Permit Project stage: Request ML23353A0692024-01-0505 January 2024 Kairos Power, LLC-Hermes 2-Environmental Report Audit Plan Project stage: Other 2022-01-10
[Table View] |
Text
November 29, 2021 Mr. Peter Hastings Vice President, Regulatory Affairs and Quality Kairos Power LLC 707 W Tower Ave Alameda, CA 94501
SUBJECT:
ACCEPTANCE FOR DOCKETING OF THE HERMES NON-POWER TEST REACTOR CONSTRUCTION PERMIT APPLICATION SUBMITTED BY KAIROS POWER LLC (EPID: L-2021-NEW-0011 AND L-2021-NEW-0012)
Dear Mr. Hastings:
By letter to the U.S. Nuclear Regulatory Commission (NRC) dated September 29, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession Number (No.)
ML21272A375), Kairos Power LLC (Kairos) submitted an application for a construction permit for the Hermes non-power test reactor, pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of Production and Utilization Facilities, and Section 104c of the Atomic Energy Act of 1954, as amended. Additionally, by letter dated October 31, 2021 (ADAMS Accession No. ML21306A131), Kairos submitted an Environmental Report in support of its Hermes construction permit application. The test reactor is to be built in Oak Ridge, Tennessee. The purpose of this letter is to inform you of the results of the NRC staffs acceptance review of this application.
The NRC staff performed an acceptance review and determined that Kairos submitted sufficient information in accordance with 10 CFR 2.101, Filing of Application; 10 CFR 50.33, Contents of applications; general information; 10 CFR 50.34, Contents of application; technical information; and 10 CFR 51.50, Environmental report-construction permit, early site permit, or combined license stage. The acceptance review confirmed that the NRC staff will be able to conduct its detailed safety and environmental technical reviews and to complete the reviews on a predictable schedule.
The NRC staff performed the acceptance review of the construction permit application in accordance with 10 CFR Part 2, Agency Rules of Practice and Procedure, Part 50, and the agencys procedures; assessing the various criteria and considerations specified in the agencys procedures associated with accepting an application. The NRC staff concluded that the application is acceptable for docketing. However, the NRC staffs determination does not preclude requests for additional information (RAIs) as the review proceeds. The docket number established for the Hermes non-power test reactor is 50-7513.
The NRC staff will conduct its safety-focused review based on the guidance in NUREG-1537, Guidelines for the Preparation and Review of Applications for the Licensing of Non-Power
Reactors, Part 1, "Format and Content" (ADAMS Accession No. ML042430055) and Part 2, Standard Review Plan and Acceptance Criteria" (ADAMS Accession No. ML042430048). The Hermes application review will be the first time the NRC has evaluated (1) tri-structural isotropic particle fuel and (2) molten salt coolant for a license or permit. A few of the novel aspects on which the NRC staff will focus its safety review include the separation of hot and cold legs in the primary system, assurance of stable flow in the decay heat removal system, tritium management, and the effects of molten salt on graphite. Because of the novel aspects of this design, the NRC staff anticipates that the application review will be greatly aided by the pre-application activities undertaken by Kairos and will continue to require additional focus from Kairos and the NRC staff to ensure a timely review.
On November 16, 2021, Kairos notified the NRC staff via e-mail (ADAMS Accession No. ML21320A217), of a possible design change in the secondary side coolant salt. Kairos stated that it does not believe that such a design change would affect the Hermes safety case.
However, the Preliminary Safety Analysis Report would need to be revised if the secondary salt is changed. The NRC staff will consider new information related to a possible design change in the secondary salt when it is submitted. A secondary salt change or other design changes could affect the review schedule.
Based in part on the extensive pre-application engagement by Kairos, the NRC staff estimates that it will complete and issue the Final Safety Evaluation Report and the Final Environmental Impact Statement by September 2023. This date could change due to several factors, including RAIs, unanticipated changes to the scope of the review, unsolicited supplements to the application, design changes, and other factors. The NRC staff will provide a review schedule with key milestones and resource estimates within 30 days of the date of this letter.
A notice of acceptance for docketing will be published by the Office of the Federal Register.
If you have any questions, please contact me at (301) 415-2062, or via email.at Benjamin.Beasley@nrc.gov.
Sincerely, Benjamin Beasley, Senior Project Manager Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No.: 50-7513 Benjamin G.
Beasley Digitally signed by Benjamin G.
Beasley Date: 2021.11.29 11:37:21 -05'00'
ML21319A354 NRR-106 OFFICE NRR/DANU/UARL:PM NMSS/REFS/ERNRB:PM NRR/DANU/UARL:LA NMSS/REFS/ERNRB:BC NAME BBeasley TDozier CSmith KErwin DATE 11/16/2021 11/16/2021 11/17/2021 11/18/2021 OFFICE NRR/DANU/UTB2:BC NRR/DANU/UARL/BC NRR/DANU/UARL/PM NAME CVan Wert WKennedy BBeasley DATE 11/19/2021 11/18/2021 11/29/2021