MONTHYEARML17068A1632017-03-0202 March 2017 NIST Center for Neutron Research Test Reactor - Request for Changes to Technical Specifications to Allow Low Power Testing Project stage: Request ML17068A1642017-03-0202 March 2017 NIST Center for Neutron Research - Statement of No Significant Hazard Resulting from License Amendment Request Dated 03/02/2017 Project stage: Request ML17097A2432017-03-29029 March 2017 Marked-up Version of the License Amendment Request of the Nbsr Technical Specifications Project stage: Request ML17153A1722017-05-25025 May 2017 NIST - Supplement for Request for Changes to Nbsr Technical Specifications to Allow Low Power Testing Project stage: Request ML17318A6952017-11-16016 November 2017 National Institute of Standards and Technology, Request for Additional Information of License Amendment Request for the Renewed Facility License No. TR-5 for the National Bureau of Standards Test Reactor (CAC No. 000955) Project stage: RAI ML17324A4412017-11-17017 November 2017 Supplement for Request for Changes to Nbsr Technical Specifications to Allow Low Power Testing Project stage: Request ML17328A5042017-11-20020 November 2017 Supplement for Request for Changes to Nbsr Technical Specifications to Allow Low Power Testing Project stage: Request ML17335A3692017-12-0101 December 2017 Supplemental Information National Institute of Standards and Technology Request for Additional Information of License Amendment Request for the Renewed Facility License No. R-5 for the National Bureau of Standards Test Reactor Project stage: Supplement ML17292A0622017-12-15015 December 2017 National Institute of Standards and Technology, Amendment No. 11 to the Renewed Facility License No. TR-5 for the National Bureau of Standards Reactor (CAC No. 000955) Project stage: Other ML18010A5622018-02-0202 February 2018 Aerotest Radiography and Research Reactor - Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML18054A2022018-02-21021 February 2018 Response to Request for Holding Information from Public Disclosure Project stage: Request ML18066A0802018-02-28028 February 2018 Submittal of Response to Request for Holding Information from Public Disclosure Project stage: Request ML18074A1112018-04-0202 April 2018 Request for Withholding Information from Public Disclosure Response to Request to Aerotest Operations, Inc. to Supplement the License Renewal Application Project stage: Withholding Request Acceptance ML21272A3762021-09-29029 September 2021 Kairos Power, LLC - Submittal of the Preliminary Safety Analysis Report for the Kairos Power Fluoride Salt-Cooled, High Temperature Non-Power Reactor (Hermes) Project stage: Request ML21306A1322021-10-31031 October 2021 Kairos Power LLC Submittal of the Environmental Report for the Kairos Power Fluoride Salt-Cooled, High Temperature Non-Power Reactor (Hermes) Project stage: Request ML21319A3542021-11-29029 November 2021 Acceptance of the Hermes Non-Power Test Reactor Construction Permit Application for Kairos Power LLC Project stage: Acceptance Review ML22024A4922022-01-10010 January 2022 Hermes CP RAI - Preliminary Questions on the Hermes PSAR, Email 1 Project stage: Request ML22028A0022022-02-0202 February 2022 Kairos Hermes Environmental Audit Plan Project stage: Other ML22041A3372022-02-0303 February 2022 Kairos Power LLC, Transmittal of Responses-to NRC Questions 2.3-1 and 2.3-2 on the Hermes Preliminary Safety Analysis Report Project stage: Request ML21364A0132022-02-0808 February 2022 Kairos Power LLC - Application for Construction Permit for Hermes Test Reactor Project stage: Other ML22040A3362022-02-0909 February 2022 Kairos Power LLC, Submittal of Response to NRC Questions 2.5-1, 2.5-2, 2.5-3, and 2.5-4 for PSAR Section 2.5 on Hermes Construction Permit Application Project stage: Request ML22040A3382022-02-0909 February 2022 Kairos Power LLC, Response to NRC Questions 2.5-1, 2.5-2, 2.5-3, and 2.5-4 for PSAR Section 2.5 on Hermes Construction Permit Application Project stage: Other ML22039A2262022-02-17017 February 2022 Audit Plan for the Kairos Hermes Preliminary Safety Analysis Report (PSAR) Section 6.3 Decay Heat Removal System - February 2022 Project stage: Other ML22089A1662022-04-0808 April 2022 Kairos Power LLC - Hermes Construction Permit Preliminary Safety Analysis Report I&C Repor (Chapter 7) Audit Plan (Cac/Epid No. 000955/05007513/L-2021-NEW-0011) Project stage: Other ML22143B0162022-05-27027 May 2022 Audit Plan for Hermes Site Characteristics PSAR Chapter 2 Project stage: Other ML22230D0762022-08-0505 August 2022 Final RCI 349 on Salt Purity in the Chemistry Control System and the Inert Gas System Project stage: Other ML22227A1802022-08-0808 August 2022 Final RAI 348 on Shutdown Rod Reliability Project stage: RAI ML22286A1672022-10-17017 October 2022 Atomic Alchemy Inc Preliminary Safety Analysis Report Pre-Submittal Audit Plan Project stage: Other ML23093A0272023-04-0404 April 2023 Atomic Alchemy, Inc., PSAR Secondary Pre-Submittal Audit Plan Project stage: Other ML23158A2662023-06-13013 June 2023 Transmittal of Safety Evaluation for Hermes Construction Permit Application Project stage: Approval ML23158A2682023-06-13013 June 2023 Safety Evaluation for Hermes Construction Permit Application Project stage: Approval ML24284A1712023-07-14014 July 2023 NRC-002B - Kairos Power LLC, Construction Permit Application - General Information (July 14, 2023) Project stage: Other ML23195A1252023-07-14014 July 2023 Enclosure 3: Environmental Report H2-ER-0000001, Rev. 0 Project stage: Request ML23181A1072023-07-18018 July 2023 Summary of August 25 and 30 2022 Public Meetings on the Kairos Hermes Preliminary Safety Analysis Report Project stage: Meeting ML23237B4652023-09-11011 September 2023 FRN: General Notice. Acceptance for Docketing of the Kairos Power LLC Hermes 2 Test Reactor Construction Permit Project stage: Request ML23290A0302023-10-17017 October 2023 Atomic Alchemy Inc PSAR Tertiary Pre-Submittal Audit Plan Project stage: Other ML23353A0692024-01-0505 January 2024 Kairos Power, LLC-Hermes 2-Environmental Report Audit Plan Project stage: Other 2022-10-17
[Table View] |
Text
KAIROS POWER LLC - HERMES CONSTRUCTION PERMIT PRELIMINARY SAFETY ANALYSIS REPORT CHAPTER 6, SECTION 6.3 AUDIT PLAN (CAC/EPID NO. 000955/05007513/L-2021-NEW-0011)
APPLICANT INFORMATION Applicant:
Kairos Power LLC Applicant Address:
707 W. Tower Ave, Alameda, CA 94501 Plant Name(s) and Unit(s):
Kairos - Hermes Test Reactor Docket No(s):
50-7513
Background:
On September 29, 2021, Kairos submitted a preliminary safety analysis report (PSAR)
(Agencywide Documents Access and Management System (ADAMS) Accession No. ML21272A375) in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of Production and Utilization Facilities, as part of its construction permit (CP) application for the proposed Hermes test reactor. The U.S. Nuclear Regulatory Commission (NRC) staff is conducting a detailed review of the CP application. PSAR Chapter 6, Engineered Safety Features, Section 6.3, Decay Heat Removal System (DHRS),
describes the DHRS and its safety function of removing decay heat when the normal heat rejection system is unavailable. This function is credited in the safety analyses of PSAR Chapter 13, Accident Analysis, to maintain acceptable reactor vessel and fuel temperatures.
Purpose:
The purpose of this audit is for the NRC staff to gain a better understanding of Section 6.3, with an emphasis on the DHRS components and how they function together to fulfill the systems safety function. Examining underlying documentation and engaging in audit discussions about the DHRS will facilitate the staffs understanding of the DHRS and its heat removal capability. If the NRC staff identifies information that is needed to support a finding, Kairos will need to submit that information on the application docket.
Regulatory Audit Basis:
The bases for the audit are the regulations of 10 CFR, 50.34(a)(1)(i), 50.34(a)(3), and 50.34(a)(4).
2 Regulatory Audit Scope This audit will focus on information provided by Kairos on the online reference portal.
Information and Other Material Necessary for the Regulatory Audit The NRC staff request more detailed drawing(s)/diagram(s) of the DHRS and its components, in particular, the steam separator and its relationship to the thimbles and float valve as well as an illustration of fluid flow throughout the components/system. In addition, the NRC staff request documentation and/or discussion related to the following topics:
Float valve purpose, fail-open performance, and redundancy.
Parameters to be monitored to ensure availability of DHRS when demanded.
Water supply to the storage tanks and any associated chemistry control.
Potential performance issues (e.g., fouling and instability in the thimbles).
Water tank isolation valve failure mode.
Team Assignments Alex Siwy Nuclear Engineer, Audit Lead responsible for audit summary report preparation Jeff Schmidt Sr. Reactor Systems Engineer Ben Adams General Engineer Alexander Chereskin Materials Engineer, (as needed)
Ben Beasley Senior Project Manager, responsible for audit logistics Ed Helvenston Project Manager Additional audit team members may be added as needed.
Logistics Entrance Meeting February 22, 2022, 1:00 p.m.
Exit Meeting Early April 2022, precise date and time are to be determined Audit meetings will take place in a virtual format, using Microsoft Teams or another similar platform. Audit meetings will be scheduled on an as-needed basis after the entrance meeting and once the NRC staff has had the opportunity to read any documents placed in the online reference portal. The audit duration is anticipated to be approximately six weeks with activities occurring intermittently during that period. The audit period may be reduced or extended, dependent on the NRC staff and Kairos progress in addressing audit questions.
Special Requests None.
Deliverables At the completion of the audit, the audit team will issue an audit summary within 90 days after the exit meeting but will strive for a shorter duration. The audit summary will be declared and entered as an official agency record in ADAMS and be made available for public viewing through the publicly available records component of ADAMS.
3 References Title 10 of the Code of Federal Regulations.
Please contact Ben Beasley at 301-415-2062 or by email at benjamin.beasley@nrc.gov with any questions related to the conduct of the audit.
Date: February 17, 2022 William Kennedy, Acting Chief Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation cc: peebles@kairospower.com bryan@kairospower.com gardner@kairospower.com Signed by Kennedy, William on 02/17/22
4
SUBJECT:
KAIROS POWER LLC - HERMES CONSTRUCTION PERMIT PRELIMINARY SAFETY ANALYSIS REPORT CHAPTER 6, SECTION 6.3 AUDIT PLAN (CAC/EPID NO. 000955/05007513/L-2021-NEW-0011)
DATED: FEBRUARY 17, 2022 DISTRIBUTION:
PUBLIC UARL R/F RidsNrrDanu Resource RidsNrrDanuUarl Resource RidsNrrDanuUtb2 Resource RidsNmssRefs Resource RidsOgcMailCenter Resource RidsACRS_MailCTR Resource ADAMS Accession Number: ML22039A226 OFFICE NRR/DANU/UTB2:SRS NRR/DANU/UARL:PM NRR/DANU/UTB2:BC NAME JSchmidt BBeasley SPhilpott DATE 02/14/2022 02/16/2022 02/16/2022 OFFICE NRR/DANU/UARL:BC NAME WKennedy DATE 02/17/2022 OFFICIAL RECORD COPY