ML20147D393
| ML20147D393 | |
| Person / Time | |
|---|---|
| Site: | Millstone, Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png |
| Issue date: | 05/31/1978 |
| From: | Goldman M CALIFORNIA, UNIV. OF, DAVIS, CA |
| To: | NRC COMMISSION (OCM) |
| Shared Package | |
| ML19261A242 | List: |
| References | |
| NUDOCS 7810140045 | |
| Download: ML20147D393 (4) | |
Text
'
UNIVERSITY OF CALIFORNIA, DAVIS
.. c asazzLzt. Davu. annxs ses Axcstas. RmRsror. sax orsco
- SAN MANCISCO k
SANTA BARBARA
- SANTA CRUS s
'.e
. maniosiotoev.ADoRATORY DAVM, CAMFORNIA 9%I6 936*752*1340 OR 7521341 May 31, 1978 d
TO:
U. S. Nuclear Regulatory Commission FROM: Dr. Marvin Goldman RE:
'Recent reports of Dr. Ernest Sternglass regarding radioactivity and health statistics around nuclear facilities in Connecticut.
I was asked to serve as a consultant to the Nuclear Regulatory Comission in this matter and to review and comment upon two reports by Dr. Ernest Sternglass.
One is " Strontium-90 Levels in the Milk and Diet near Connecticut Nuclear Power Plants," dated October 27, 1977, and the other appears to be testimony dated February 10, 1978 for a Congressional eninar and is titled " Cancer Mortality Changes Around Nuclear Facilities in Connecticut." Although I am Director of a large radiobiology laboratory at the. University of California, the views ex-pressed herein are entirely my own and in no way im;1y any endorsement or assess-ment by the University of California or the Federnt agencies who support the laboratory's research.
For the past 27 years I have been engaged in radiobiologic research related to the dosimetry, metabolism and pathology of radionuclides.
In particular, a major effort involves studies of radiostrontium and its effects.
Dr. Sternglass alleges that levels of strontium-90 (physical half-life of about 28 years) and cesium-137 (physical half-life of about 30 years) around Haddam Neck and Millstone Point nuclear power plants have been increasing mark-edly as a result of plant emissions and that these levels pose a " serious threat to human health."
I do not agree with these conclusions.
In reviewing the information avail-able to me I conclude quite the contrary. There are several reasons that prompt me to seriously question the validity of Dr. Sternglass' conclusions.
One central factor relates to the well imown fact that Sr-91 Land Cs-137 are long-lived fission products resulting from the fissioning ofQertiihlements such as U-235 and P,-239.
Fur-hermore, it is also well documented that as a result of atmospheric weapons testing (especially some 15 years ago) that the
' entire land surface of our-planet is, to a variable and frequently measured degree, contaminated with low levels of these (and some other) radionuclides.
It is also known that when uranium-235 is fissi~oned, a host of radionuclides of varying half-lives are generated. This is true of both weapons related fission-ing and of nuclear fuels in an operating reactor. One additional fact that Y\\4-14 %
Dr.<Sternglass seems to have not taken into account is that recent fission product mixtures 'will contain short lived radionuclides as well as long-lived radionuclides.
De fra'etion of short-lived radionuclides will decline with time after fissioning ~
and at late times only the long-lived species may be detected in environmental
' samples. This ability to "date" the radioactivity, or at least confirm it is of
~
recent origin is an is..ortant and relatively " fool proof tool."
Wat Sr and Cs both exist in freshly produced fission products in the forin of several isotopes is fortuitous and significant. Generally speakipg, consider-ably more "short-lived" Sr-89 (half-life s50 days) is produced and to a limited i
extent released than the longer-lived Sr-90 In tems of relative activity, de-pending on sampling time, about 5 pCi of Sr-89 might be released for each uCi of Sr-90. Thus even correcting for the decay of radioactivity from " release" to incorporation into the food chain (e.g., milk and other locally produced food stuffs), there must be some Sr-89 present in foodstuffs with Sr-90 of recent origin. The nuclear plants do record the annual totals of both strontium iso-topes released and do record the levels in their periodic environmental samples.
If this is true, my question is where is the Sr-89? The methodology seems to be sufficiently sensitive to have picked this up following some Chinese atmospheric 1
weapons tests; both Sr-89 and Sr-90 (e.g., 10/5/76 samples of milk which also showed 8 day I-131) were measured.
l Furthermore, the alkali earth element cesium is represented by shorter. lived isotopes, particularly the 2.1 year half-life Cs-134 This isotope is released along with the Cs-137 from nuclear reactors in very small quantities (e.g.,1972 Millstone 16.4 Ci Cs-137 plus 8.8 Ci Cs-134). The activity ratios are similar -
about the same number of microcuries of each isotope released annually. Since their respective decay emissions are sufficiently different, any detector sensitive j
enough to identify one can distinguish it from the other - their gamma ray and
)
beta particle energies are different. Thus, I must question the conclusion that j
the Cs-137 measured in food stuffs was recently released from the nuclear plant in question. If so, where was the Cs-1347 There are no pathways to man which separate these two isotopes of the same element. The element cesium will behave like cesium whether it is Cs-137 or Cs-134 The element strontium will behave like strontium whether it is Sr-90 or Sr-891 2n light of the frequent sampling schedules, it is not possible for the short-lived radionuclides to have decayed to non-detectable levels relative to those measured for the longer-lived isotope. Thus, I am forced to conclude that the only explanation for the data shown is that whatever the nuclear plants re-leased was completely masked by the " background" level of Sr-90 and Cs-137 from fairly old atmospheric deposits, i.e., earlier weapons tests.
'!he Sr-90 and Cs-137 shown in national monitoring data varies from place to place and with time.
In food stuffs, some of the variation is related to the degree of fresh foliar deposition on vegetation and cattle forage as well as root uptake from soil deposits.
In addition, the local rainfall pattern may " wash on or off" varying amounts of atmospheric fallout on vegetation surfaces, as well as leaching more deeply into the soil that which was deposited on the surface.
Globally, millions of dollars have been spent on studying a6d quantifying these phenomena and their variations. Depending on how one calculates a mean or average value, individual samples may vary by ten fold in repeated sampling y
n--- - -'r-
'--m-=
e:.
-n.
g...---g w.
,.,-w.,,.-
__,__m-___,,._,_.______.,_,,__,_.,___.__m.
O (compare milk Cs-137 in April vs. May 1976 for U. S. cities). % e time trends and specific levels have shown me no significant levels which I feel can be
. attributed to plant releases. On the contrary, the data strongly indicate that the Sr-90 and Cs-137 measured in food pathways samples are almost all, if not entirely; the result of atmospheric weapons test fallout.
A fatal flaw in Dr. Sternglass' analyses is the manner of selection of data. One cannot select a particular sample as meaningful unless th'e other accompanying radionuclides are all present and the environmental pathway moni-toring is consistent. Dus, for milk to contain nuclear plant Sr-90 and Cs-137, it must also have the other nuclides, Cs-134 and Sr-89 (and I-131 I might add).
%ese findings would have to be confirmed by air and liquid samples and the plant monitors would also have to have shown "down stream" increases. I do not find support for these requirements and conclude that the local measurements are reflections of the local temporal weapons fallout situation.
Another problem of apparent misinterpretation of data relates to the re-porting of cancer death rates. Connecticut probably has one of the best state tumor registries in the country and I would imagine that the State officials may have their M analyses of the trends of cancer mortality.
I reviewed the gen-eral s~ dt acs on cancer published annually by the American Cancer Society in its "~ '
i vacts and Figures." For example, it was of interest to note that in t.d States, overall cancer mortality has steadily risen from about 160 per thousand in 1970 to about 170 per hundred thousand in 1975. The ACS publi_..ec annual Connecticut rates which are generally in agreement with those values. I did not check on the State registry as I wished to determine whether the State was following a different trend than the Nation, n e data for both Connecticut and the U. S. show increases which are largely influenced by the increases in both sexes of lung cancer related to cigarette smoking.
If Sr-90 was indeed increasing, and it does not appear to be the case, its deposition in the body would incur an increased dose to bone and marrow. Strontium is an alkaline earth element which concentrates in skeletal mineral as does calcium, about one thousand fold greater than in other tissues. Extending this hypothetical situation further, one might have expected an increase in bone cancer and leukemia were serious skeletal and marrow irradiation resultant from radionuclide burdens.
There is no data in support of this.
I calculate that between I and 3 mrem per year is absorbed by adults and children respectively from milk containing a con-stant picoeurie of strontium-90 per liter.
If I accept a milk concentration of about 10 pCi SOSr/ liter, this would account for about 10-30 mrem per year to bone and about 3-10 mrem per year to marrow. nis value is close to that which we all receive from the traces of radium present in our drinking water.
What health effects might result from ske'letal irradiation associated with Sr-90? The National Academy of Sciences estimates that about 0.2 bone cancer deaths per year would be expected per population of one million per rem absorbed.
his would translate in a Connecticut population of about 3 million to 0.6 bone cancer deaths per year per rem and also to 0.6 cases times 0.03 rem (30 mrem) or 0.018 cases per year attributable to the Sr-90 skeletal dose. Using these conservative estimates, one would predict about I such death every fifty years consequent to a 30 mrem bone dose added to the State 50 year total of 1000 to 2000 deaths from this disease (I estimate a bone cancer death rate of about 1
4 per 100,000 per year in Connecticut; i.e., about 30-40 per year). There are other ways of calculating radiation cancer risks, but I included this example to put the risk per absorbed dose question in perspective and in a form which is frequently used by experts in this field.
burdens derived by ingestion to induce cancers in other organs to the ex skeletal mineral,of bone and marrow since the radioelement concentrates so pref d
In conclusion, I have not found support for the contention that the Connect-icut nuclear plants have released sufficient radionuclides (Sr-89, 90 and Cs-137 134) to have caused significant radiation exposure of the population; such e sures art a minute fraction of those attributed to atmospheric nuclear weapons furthermore, the radiation doses associated with Sr-90 (from all sources) tests.
are very significantly below those associated with observable changes in ca.ncer risk.
As v. final note, it is generally accepted by the National Academy of Sciences that bone cancer risks from prior radiation would be accompanied by a latent period of about 15 years, and not six years.
I can only conclude that the variations in health statistics presented by Dr. Sternglass, if correct plants in Connecticut and that there is no evidence to su are that these plants have posed a " serious threat to human health."
MG:pw I
{
l f
l
-