F0E0V0m 1

o Nuclear TMI Environmental Controls Policy and Procedure Manual 6615-PLN-4520.01-litie Ft. vision No, I

Radiological Environmental Monitoring Program - Plan

-1 epocan,aw scop.

m.pon.,ei. omes ENecove Date This system is for radiological environmental monitoring 6615 10/30/92 Within OA Plan Scope X

Yes No Safety Reviews Required X

Yes No 1

Ust of Effective Pages Paco Revision Paae Revision Pace Revision Pace Revision 1.0 1

2.0 1

3.0 1

4.0 1

5.0 1

6.0 1

E11 1

E12 1

El 3 1

E14 1

E15 1

E16 1

E17 1

E2-1 1

E2 2 1

E2 3 1

' E2-4 1

E2-5 1

E3-1 1

E 3-2 1

Signaturs Date Originator:

[g

' Cognizant Scientist

  • /

f(( [-

Y

.)

(

v Concurred By:

RTR 9 19 Q

?

Environmental Programs Manager g

Standards Committee

[

y/

gr. E ironmental Controls, TMI 46 /dh 1.0 nm

~

9301110221 930104 PDR..ADOCK. 05000320

P PDR

\\

nn.,

~

[r (') j gdgy TMI Environmental Controls Poney and Procedure Manual 6615 PLN-4520.01 1 st's Nvis.on No Radiological Environmental Monitoring Program Plan 1

l Jable of contents

_Section Paco 10 DEFINITIONS 3.0 20 PURPOSE 3.0 30 APPUCABluTY/ SCOPE 3.0 40

SUMMARY

OF REMP 30 41 Program Requirements 3.0 42 Sample Collection 40 43 Sample Preparation and Shipment 40 44 Sample Analysis 50 4.5 Reviews / Audits 5.0 46 Reports 6.0 4.7 Training 60 48 Organization and Responsibility 6.0 50 REFERENCES 6.0 5.1 Regulatory Requirements / Guidance 6.0 5.2 TMINS Offsite Dose Calculation Manual (ODCM) 60 60 ATTACHMENTS 60 61 Exhibit 1 - TMINS REMP - Sampling Locations El 1 62 Exhibit 2 - TMINS REMP - Sample Collection and Analysis By Media E21 63 Exhibit 3 - REMP Regulatory Requirements / Guidance E31 2.0

==

I FOR1NFORMAT10k ONLY.

I Nurnt>er 4MCl88r M EnWonmemal Controls

- Policy and Procedure ManualT 6615 PLN-4520.01 -

Tme Aevisen No.

.)

Radiological Environmental Monitoring Program - Plan -

1

't 1.0 DEFINITIONS Radioloaical Environmental Monitorina Procram (REMP) That system of environmental sample collection, analysis, and data reporting utilized to monttor radioactrvity in the environment around the Three Mile Island -

Nuclear Station (TMINS). The REMP includes both Nuclear Regulatory Commission (NRC) required -

monitoring, as well as monitoring which is not required by the NRC.

Laboratory - A laboratory under contract or sub-contract to GPU Nuclear Corporation or Company -

laboratory for the purpose of environmental radiological sample analysis and subsequent data reporting.-

Anomalous Values Reported value which is inconsistent with what would normally be expected or a value.

Outside an estab'ished range.

GPU Nuclear Corporation (GPUN) - A subsidiary of General Public Utility Corporation (GPU) which is responsible to operate GPU nuclear fueled electric power plants.

2.0 PURPOSE To provide a description of the Radiological Environmental Monitoring Program (REMP) conducted in the _

vicinity of Three Mile Island Nuclear Stations (TMINS) and to define program requirements.

4 3.0 APPLICABILITY / SCOPE 3.1 This PLAN is applicable to all Three Mlle Island Environmental Controls (TMI-EC) personnel and their designees.

3.2 Any aspects of this document which conflict with applicable laws, rules, l_icent,es, regulations, permits, orders and decision of courts. and regulatory agencies, are to be promptly brought to the -

attention of the Manager, Environmental Controls. TMl or designee who shall determine appropriate-action.

33 This PLAN addresses the full REMP program which includes; as a subset, the program as required by the Nuclear Regulatory Commission (NRC) for TM11 and TMI 2.

3.4 This PLAN is maintained and controlled by the Manager, Environmental Controls. TMI or designee.'-

3.5 The Manager, Environmental Controls + TMI and staff are responsible for the execution of the REMP.

4.0

SUMMARY

OF REMP -

4,1 Program Requirements 4.1.1

_ The REMP shall, as a minimum meet the requirements set forth by the NRC for TMINS and L

additional commitments made by GPUN.

4.t.2 in addition to th'e NRC required program, the REMP may include that which is deemed f necessary by the Manager. Environmental Controls-TMI. to determine the environmental -

~

impact. if any, of releases.

l l

3.0 mu

,, ~. -. -

4

45

%bi! A n g 7 -

Numb:r

[c c > 1 Nuclear M EnWonmental Contrds Policy and Procedure Manual 6615 PLN 4520.01 Tit:e Revissori NO Radiological Environmental Monitoring Program - Plan 1

41.3 Alt sarnpling instrumentation utilized in the REMP shall be calibrated as appropriate using approved procedures, and all equipment shall be property maintained.

4 1.4 A riuality control (OC) laboratory which is independent of the primary leoratory, to the extent practical, shall be contracted by GPUN for the purpose of companng/ confirming the analyses resu!!s of the primary tab.

41.5 A land use cen3us shall be conducted annually in accordance with the NRC requirements for TMINS.

4.1.6 The laboratories performing analyses on environmental samples shall participate in an NRC approved interlaboratory companson program 42 Sample Collection 4 2.1 Samples shall be collected in accordance with approved GPUN procedures.

4 2.2 Exhibit 1 of this PLAN defines the REMP Sampling locations and lists the station type (indicator vs. control) and the media which may be collected at each location.

42.3 Samples at additional monitonng locations may be obtained at the direction of the Manager, Environmental Controls - TMI or designee.

4.2,4 Exhibit 2 of this PLAN defincs the collection frequency for each medium.

4 2.5 The frequency of collection may be modified at the direction of the Manager, Environmental Controls - TMI or designee.

NOTE Exhibits 1 and 2 will be updated on an annual basis, as necessary.

4.3 Sample Preparation and Shipment 4 3.1 Samples shall be prepared in accordarce with approved GPUN procedures to ensure sample integnty.

4.3 2 As necessac/, samples shall be preserved to mitigate biological growth and/or to reduce the absorption of radioactrve isotopes on the container walls. The use of such methods shall be in accordance with approved GPUN procedures.

4 3.3 When samples are sent/ delivered to an analytical laboratory, GPUN shall provide the laboratory with specific Instructions regarding the type of analysis each sample is to undergo.

4.3.4 Samples shall to be shipped, received and analyzed in a timely manner. GPUN shall track the sample to and from the laboratones by the use of a manifest tracking system (e g.

collection sheets and running tables),

4.0 un.

FOR INFORMATION ONR l

J Number (ggp-TMI Environmental Controls Pokey and Procedure Manual -

6615-PLN 4520.01 Titte Revissort No Radiological Environmental Monitoring Program Plan l

1-4 3.5 Sample collection / receipt forms shall be retained b/ GPUN.

44 Sample Antlysis 4 4.1 Samples shall be analyzed in accordance with labc<atory procedures which are to be reviewed and approved by GPUN.

4 4.2 The analysis frequency and the type (s) of analysis performed on each sample are desenbed in Exhibst 2 of this PLAN, 4 4.3 The analysis frequency may be modified at the direction of the Manager, Environmental Controls - TMI or designee 444 The analyses performed on the samples may be modified at the direction of the Manager of Environmental Controls - TMI or designee.

4 4.5 At a minimum, the samples shall be analyzed to sensitivttles (LLD) at or below those defined by the NRC for TMI-1 and TMI 2.

4.5 Reviews / Audits 4.5.1 Laboratory Responsibility 4.5.1.1 Analytical results of environmental samples and intertaboratory comparison program samples shall be issued on a timely basis to GPUN for review.

4.5.1.2 The laboratories performing analyses on environmental samples shall maintain a quality assurance (QA) program consistent with NRC Regulatory Guide 4.15.

4 5.1.3 Laboratories performing.inalyses on environmental samples shall periodically supply OA program cata summaries to GPUN 4.51.4 The laboratory shall review the data and check for anomalous values.

4.5,1.5 If an anomalous value is discovered. the laboratory shall notify the Environmental Programs Manager at TMI-EC or designee. The Environmental Programs Manager at TMI or designee may at that time request follow up action to confirm the anomalous value. This may include a recount and/or a reanalysis of the sample.

4.5 1.6 If requested by GPUN, the laboratory shall prepare a wntten report detailing the anomalous value. This report with analysis resutts shall be sent to the.

Environmental Programs Manager at TMI-EC or designee.

4.5.2 Environmental Controls Responsibility

~

4 5 2.t The data from the laboratories shall be reviewed in accordance with approved GPUN procedures.

5.0 ma

340 WOGAfri' 4e A

ua

~

semi >..

[rgj1 Nuclear i EnWonmental Conus Policy and Procedure Manual 6616-PLN 4520.01 Tme Revision No.

Radiological Environmental Monitoring Program Plan 1

4 5 2.2 At a minimum, the data sha!! be reviewed to determine tf GPUN Action Levels (Pro.

6615-SUR-4523 05 and 6615-SUR 4523 06) and/or NRC reporting levels have been reached or exceeded-4.5.2.3 This review shall also include a comparison of the primary (main) and OC laboratory results (Pro 6615 SUR 4523.03).

4.5.2.4 Corrective action shall be taken in accordance with approved GPUN procedures (6615 SUR-4523.03,6615-4523.05 and 6615-SUR 4523.06, as applicable).

46 Reports 4 6.1 Applicable REMP reports shall be prepared in accordance with GPUN approved procedures and NRC Technical Specifications (Appendix A Section 6.9 for TMI-1 and Appendix B Section 5 6 for TMI-2).

4.7 Training 4.7.1 Each individual involved in the REMP is responsible for understanding and following procedures in the area of their responsibility. If additional training is required, further guidance by an appropriate individual (s) will be provided.

48 Organization and Responsibility 4 8.1 The Manager. Environmental Controls - TMi and staff are responsible for the complete management of the REMP in operation at TMINS. This responsibility encompasses all phases of the program, including sample collection, sample delivery to laboratories, sample analysis, review of data, and preparation and submrttal of regulatory reports.

50 REFERENCES 5.1 Regulatory Requirements / Guidance Exhibit 3 provides a listing of Regulatory Requirements and guidance used to develop REMP at TMI.

5.2 TMINS Offsite Dose Calculation Manual (ODCM) Procedure 6610 PLN 4200.01 60 ATTACHMENTS 61 Exhibrt 1 - TMINS REMP - Sampling Locations 6.2 Exhibit 2 - TMINS REMP - Sample Collection and Analysis By Media 6.3 Exhibit 3 - TMINS REMP Regulatory Requirements / Guidance 60 neu

FOR INFORMATIONN NumbW

- (gglggy M EnWonrnental Conuds 4

Policy and Procedure Manual 6615-PLN-4520,01--

7,gi, _

Rnytston No.

Radiological Environmental Monitoring Program - Plan

-1:

EXHIBIT 1 TMINS REMP Sampling Locations Stat 60n Sarnple Distance A2imuth Station CAe Lads Desenotion (M8es) p.t,m,te3..

Typea A1 1 10 N of sne. Nortn Weather Station. TM1 04 0

t Ala 10 N of RB centertme on W tence ad;acert tc N Weatner Station TM1 03 5

l-B11 10 NNE of sne on light pede m rneddie of North Brdge TMi 06

.25 i

D 1 -2 10 NNE of RB centenene at top of d*e. TM1 04

. 26 I

81-3 10 NNE of R8 contenine on W Fence adiacent to S end of N bndge. TMi 05 15 -

1 Bl4 AP.Al NNE of sne at North Gate Guard Shack 08 26 I

Cl 2 10

' NE of RB certonine at top of dee. TMl 03 54 1

01 =1 10 ENE of sne on top of dae, east tence. TMI 02 74

-1 E14 10 E of site on top of dee. east tence, TMt 02 95 i

E14 ID E of RB centenme at top of dee. TMi 02 98 1~

F12 10 ESE of RB centertme at top of d*e midway wahm interirn Solid Waste Staging 02 109 -

1 Facday, TM1 G13 10 SE 'Jf RB centertine et top of dAe Tui 03 129 i

M t.1 10

$$E of site TMI O5 167 i

H13 FP SSE of site at resalence m Red Hdi Plaza 07 150 i

H1 ID SSE of R8 centeriene at top of d*e, TMi 03 167 1

J1 1 10 S of site at south beach of TMi 08 184 1

Ji 3 10

$ of RB certeetine on wooden post by o6d S Gate Guard B6dg. TM1 -

03-

-189 -

I' K1 1/1 A EW RML.7 station discharge. TMi 02 209 l

Jia 10

$ of site. TML G4 188 I

Kid 10 SSW of RD centertoe on tence behind Warehouse s2. TMt 02-208

'i KO5 -

10.

SSW of RB certertme on tence behind Warehouse e3. TMI

-02 202-

't Lt.1 10 SW of sae west of mechanical dran towers on des TMt 01 235 t

N14 ID W of saa on Shelley Island 07 270 1

P13 SW.

Station mtake (Unit 1). TM1 01 284 C

N13 10 W of RB centertine on fence adjacent to screenhouse entrance Gate TM) 01 270 i

Page 1 of 7 -

Et 1

MV NOi} Nlf$3y

,g, Nurnber le L)i Nuclear M Emironmental Conads Policy and Procedure Manual 6615 PLN 4520.01 Lt:e Revision No Radiological Environrnental M9nitoring Program. Plan 1

EXHIBIT 1 (Cont'd)

TMINS REMP Sampling Locations Station Samse Distance A2imuth Staton Code __

M eum Descreon fMdes)

Deorees Type a P1-1 ID WNW of sne on SheNey island 04 293 i

C11 10 NW of sde on Sheuey Island 0$

317 l

Q12 ID NW of RB centertino on fence behind Warehouse e1 TMI O2 3t8 i

Rt-1

!D NNW of site at gate m fence on W see d TMI, North boat dock 02 335 I

A12 AOS N of sde at north tip of Sand Beach Island 08 6

C A1 -3 AOS N of sne at north t:p of TMi 05 0

C C1 1 ID NE d sne on Route 441 07 35 i

01 2 10 ENE of sne on Laured Road 06 60 1

El-2 AP Al. RW E of sne TMt Observaton Center 04 95 I

10. S. FP, AT. GW ib1 ID.FP.S ESE of sne off Route a41 at entrance to 500 kV substaten 05 117 i

F l.3 AP.Ai ESE of saa msde fence at 500 KV substaten 06 105 I

Gt 1 ACS SE d sae 03 137 i

G t.2 10 SE of sne on Route 441 06 143 1

J t -2 SW S of sne below discharge pipe 05 188 I

n t -3 AOS SSW of s4e 03 202 i

Lt 2 ID SW of sie on Beech Island 05 221 1

RI-2 10 NNW of sne on Henry Island 07 332 1

A21 MG FP N of sne farm along Route 441 12 5

1 02-1 M.S FP ENE of sae, farm on Gmgnch Road i1 65 i

G2 2 S

SE of saa on Engle Road 12 125 I

J21 SK AOS S of sne aoove Yore Haven Cam 15 182 I

J2 2 FP,S S of saa near York Haven Carn 15 178 1

>2 1

D SSW of s.to on S beach of Sheitey island 11 200 I

L21 LD SW of sne on Route 262 19 227 i.

Page 2 of 7 El-2 mu

FOR INFORMAT10N ONLY Nurnber MUClear

M Emironrnend Connois Policy and Procedure Manual 6615 PLN 4520.01-Illie Revision No.

1 Radiological Environmental Monitoring Program - Plan

-1 EXHIBIT 1 (Cont'd)

TMINS REMP - Sampling Locations Station Sarnpa Distance Azanoth -

- Staten -

Code Medeum Desenotion IUdes)

' Deartes Type a WSW of sne ad acent to Fistung Creek. Gosdsboro Air Stanon 1.3 253 I

M21 AP. Al AT.

i RWIQ M22 FP WSW cf sne at rescence on Route 262 Goldsboro 13

-252--

I.

N2-1 10 GW W of sne at Goldsboro Manna 12 262 i

N2-2 FP W of sne at resioence in Goldstoro 13 265 i

P2-1 10 WNW of sne off of Old Goldsboro pas 19 283 1

Q21 10 NW of saa on access road along rrver 18 310 i

Alt AP.At10 N of sne at Matdletown Gubstaton 26 358 i

RW. AT A3 2 SW N of sne at Swatara Creek 25-355

,C.

Ft AP Al.

SSE of sne at Falmouth-Colkns Substalon 2.3 159 l

RW.10 A51 ID N of sue on Vine Street ein from Route 283 43

.3 1-85 1 ID NNE of sae. School House Lane and Mdier Road

-48 IB-t C5-1 10 NE of sne on Kennedy 1.ane 45 42-I D61 10 ENE of sne oft of Beagle Road 52 65 i

E51 10 E of sae. Notin Market Street and Zeager Road 46 81

_i F51 10 ESE of sne on Amosna Road 47 107> C5-1 10 SE of sne B=nbndge and Risser Roads.

48 131 1-MS-2 SW

- SSE of sne on Brunner Island 42' 157 i

MS-1 10 SSE of see at Guard Shack on Brunner island 41 157

-1 J51 ID S of site on Canal Road. Conewago Heights 49 182 i

K5-1 to SSW of sne on Conewago Creen Road. Stnnestown 50

-200

-l L51 10 SW of sae. Stevens and Wdson Roads 41 228 I-M5-1 10 WSW of sne. Lewisberry and Roxberry Roads. Newberrytown 43 249 I-N51 10 W of saa. off of Old York Road on Robin Hood Drrve 49 268 -

'l'-

i; j

.Page 3 of 7 L

E14 '

mu i

r I.

T'

... - ~

. ~. -,.,.

WO M D s se ::D dly sum,,,-

(UClear'-

TMI Environmental Controls Policy and Procedure Manualu 6615-PLN-4520.'01 -

Title.

Aevision No -

Radiological Environmental Monitoring Program Plan 1L L

EXHIBIT 1 -(Cont'd)

_ TMINS REMP. Sampling Locations -

t 2

Staten Sample Destance.

A2Wnuth Staton =

Code Medom Descnotion (Maest Oearpeg Typea PS-1 10 WNW of sne. Route 262 and Betnhower Road 49-285 -

t 04-j AP.Al NW of see outado securry gate at Hamsburg inti Astport 3 5.-

325 :

I' 05 1 10 NW of sne on LumDer Street. Hegnspire 50 318 i-RS-1 10 NNW of sne. Spring Garden Ortve and Route 441 49 339 i--

B101 10 NNE of sne. West Areca Avenue and Mdl Street. Haeshey 94 21 i

C81 ID NE of sae. Shenks Church on $chool House Road 72 48 -

-1 09 t 10 ENE of sne on Mt Gretna Road. Bename 85 72 1

- E71 10

. E of sne on Nummeistown Street. Eltzabethtown 68 66 -

I E6-1 FP E of sne. orenard at Masoruc Homes 59 100

.I' F 10-1 10 ESE of sae, Donegat Sprrigs Road. Donegal Sonngs 94

-112J

-1 G10-1 AP. Al RW SE of see et farm off Engle's Toligate Road 98 127 C

to, S.

H81 10.

_SSE of sne on Saginaw Road. Starvww.

74 163 I

J71 10 ~

S of sne on Maple Street. Manchester 65

-177 I:

y KO 1 10 SSW of sne. Coppenhafter Road and Rt 295. Zon's vww 74 196 1-LB-1 10 SW of sne on Hohler's Church kd. Ancersontown 80-

.22$

l 0

WSW of sne on AJpine Road Maytown 86' 242 1

M91 1

N81 ID W of sne on At 382, t/2 tru North of Lewisberry 78 260 I?

F81 10 WNW of sne on Evergreen Rd. Reeser s Summa -

80 292 -

I

- P7-1 M FP WNW of sne on Old York Rd, New Cumbertand 67 293

-- I -

00-1'

'SW.ID NW of sne across from pwg tot of Steetton Water Company -

85-308

~l.

R9-1

-10 NNW of site on Derry SL Rutherford Hgts 81 340:

.I A15-1 FP' N of sae, farm on At 39. Hummelstown

.10 $

' 10

.C:

A t S-2 MG. FP

N of sne farm at entersect6cn of R122 and Crawford Rd 14 2 9

C' C201 10

. NE of sne on Cumbertand $t. Lebanon 19 6 -

47.

C; 015-1.

10 ENE of sne Rt 241. Lawn, PA 10 9 -

63 :

-- C -

Page 4 of 7 El-4 m

._ u

_j

x

FOR INFORMATION ORI.Y Numoor

-(UCl88r i EnWonrnental Comds -

Policy and Procedure Manual 6615 PLN 4520.01 Tatie.

Revision No -

Radiological Environmental Monitoring Program Plan 1

+

EXHIBIT 1 (Conth)

~

~

TMINS REMP - Sampling Locations Stauon Sample

- Distance Azimuth Stanon ~

Code Medium Descrircon (Mdest Oeorees Typee F25-1 ID ESE of sae. Steel Way and Loop Rosas. Lancaster 21.1 113

'C F t 5-1 SW ESE of sne Chickies Creek 12.6 12f C-G15-t SW10 SE of sne at Columtxa Water Treatmers Ptant 14 4 124 1/C G102 SW SE of sne. Wngnisvene Water Treatmers Plant

-13 6

. 128 i.

G15 3 SW SE of sne. Lancaster Water Treatment Ptant

'14 8 124 6

- H15-1 10 SSE of sae. Orchard ano Stonewood Roads Wilshere Mdis 13 2 157 C

J151 AP.AlID S of sne ri Mat Ed York Load Dispatch Station 12 6 100 C

AT J15 2 SW ~

S of saa at York Water Company

.14 7 178

-C K15-1 10 SSW of sae. Alta Vista Rd. Weglestown at Dover Twso Fire Dept Bldg

-12 7 -

204 C

L:5-1 10 SW of sne on West see of Rt 74, Mt Royal

.11,7 225 -

-C L15-2 M FP SW of sae at farm on Rt 74 just N of Dover 12 1 219 C-M151 10 -

WSW of sne. West see of Rt 74 in front of Earth Crafts. Rossvele 11 9 237 C

MIS 2 FP WSW of sne on W sde of Rt 74. Larew's orchard 13 6 253 C

N15 2 10 W of sae, Usburn Rd and Main St. Usburn

.10 4

-274.

C P15-t 10 WNW of sne on Erford Rd in front of Penn Harns Motel Camp Ndl 12 2 300 C

Q 15-1 AP.AI RW NW of sne at West Fairview Substation 13 5 -

305

-C

10. S R151 10 NNW of sne Rt 22 and Colorual Rd Colorwal Park 11 2 330 C

A91 S

N of sde off of thon Deposa Road 92-0 C-7 A9 2 S FP N of sne on Union Deposa Rd. W of Hoemerstown 93-357-C-

Ei 3 FP E of sae 100 m W of Peck Rd and Zlon Rd intersect:on 07

' 90

'i E2-1 S,FP E of site on Zion Rd

.I1 80

,I i

G21 M FP.AP.

SE of sne. farm on tne E sde of Conewago Creek 14' 125 1

Al AT, RW G31 S

SE of saa on Govemor a Statne Road i28

-131

-I Page 5 of 7"-

~

b El-S w

_,y,

..,-+g,

,1--,

. -i

1 d

b 5O NOlId'(D038 w$

Namocr

="*oa"*"ta' co**

W-)i Nuclear Policy and Procedure Manual 6615-PLN 4520.01 Revision No-Titie Radiological Environmental Monitoring Program - Plan 1

EXHIBIT 1 (Cont d)

TMINS REMP Sampling Locations Station Sarnpie Distance Azimuth Statton At Modum Descnoton (udest peareej Type a P31 FP WNW of sne on Rt 392 (Yocumtown Road) 26 293 I

Ind<ator AQF ACP AllIctations where fish and Mants are collected below the discharge are grouped I

together and retenM to as *indcator (1 e. sectors 11 and geograptwcally below)

Control AQF. ACP Alllocatons where fish and Mants are collected above the discharge are grouped C

togetner and referred to as contrer (i e. Sectors 12 and geograpnically above)

A3 3 S

N of sne at junction of Swatara Creek and Route 4a4 25 354 1-H1 -2 FP SSE of vte, stand off of Rt 44 09 150 l

D13 FP ENE of sme. house next to Yirger: Greenhouse on Rt 443 05 65 t

G2-3 S

SE of sae. near Conewago Crer 16 132 i

K15-2 M.FP SSW of sae along Rt 74 N at Ashcomoe s Daay Farm 12 8 208 C

A9-3 10 N of saw at Duke St Pumping Station Hummeistown 81 3

I Rt5 2 ID FP,S NNW of sae at EOF Hamsburg 12 4 3 21, C

Mi1 10 WSW d RB contortine on SE comer of Una 2 Screenhouse fence. TM1 01 249-1 F31 M FP ESE of saa at farm on Hillsdale Road 23 104 i

E2 2 M.FP E of sat at farm on Pecks Road 11 93 i

B 15-1 7

NNE of sae at Fruit Market on Rt 39 10 3 12 C

B2a 13 NNE of sne en Sunset Dr (off Hillsdale Rd )

19 16 i

C21

!D NE of sne at Mddletown Juncton 16 48 i

D21 10 ENE of saa en Ndisdale Pd. (S of Zion Rd )

17 73 i

E2 3 10 E of sne on Hdisdale Rd (N of Creek Rd )

19 96 i

F21 10 ESE of sne on Engle Rd.

12 120 i

G2-4 10 SE of s:ta on Becker Rd 18 145 I

G17 iD East Shore at High Water Mark. TMi 03 144' 1

G14 10 East DAe S End of Paint Shed. TML 03 146 I

GI 5 10 East Dike Mddle of Paint Shed. TMi 03 144 1

01-6 10 East D*e. N End of Paint Shea, TMt 03 141 i

Page 6 of 7 E14 ma

-

  • z l

FOR INFORMATiON DEY-Number Nuclear M EnWonmenal Conus Policy and Procedure Manual 6615 PLN-4520.01

. Ilf te..

ROVision No.

Radiological Environmental Monitoring Program Plan--

-1 EXHIBIT 1 (Cont'd)

TMINS REMP - Sampling Locations Staten Sampo Distance Azimutn

- Station :

AL Mecom Desenoton (Miles) -

DeWtes Tvoe a

- J3-1 10 S of sne at iort Haven /Cly.

27 178 ~

t K31 10 SSW of sne on Rt. 262 N of Cly

.21 202

'I J3-2 AP.Al S of site at substauon in Cay 29 181 1

R31 10 NNW of sne at Crawford Staten. Meadletown 26 338 I:

P12 ID N of TMb1 Screenhouse. TMi 0.2 290 t

Mi2 10 WSW of sne on W sde of unnamed island between N tip of Beech island and Shelley 0S 241 I

island A4 1 M.FP N of sne at farm along Rt 230

'33 1 Indcator GAD, ROD All locations wethin 10 miles of TMINS 1

Contral -

GAD. ROD AA locations greater than 10 rnaies from TMINS

'C-3taten Type t = indcator. C Controi I

IDENDRCADON KEY l

10 tmmersion Dose (TLD)

RW Rain Water AGF = Fish 4

-SW. Surface /Dnnairs Water M

' Mdk (Cow)

AQP '. Aquate Plants

=

At locine MG Al Mik (Goat)

AOS = _ Aquate Sediment

=

Aa Particulate EW

  • Effluent Water FP = Food Products (Vegetatses. Frun Green leafy vegetation '

AP

=

S Sod GAD = Meat (Game)

GW. Groundwater (oftsael

=

AT _. As Tntium ROD = Rodent

-, Page 7 of 7 -

a Y

E1-7 i

-m

~

..-n

,=,

".WO MOIT AN!P

~ max

[r g-)j g g g y TMl Environmenta! Controls Pokey and Procedure Manual 6615-PLN 4520.01 ritie NYlSIOrn NO.

Radiological Environmental Monitoring Program - Plan 1

EXHIBIT 2 TMINS REMP Sample Collection and Analysis by Media Sample Collection Analysis Analysis MMfium (a)

Frequency (b)

Type (a)

Freoutmcv(b)

  • Air Particulate [5]

Weekly (c)

  • Gr Beta (d)

On each sample (AP)

Gr Alpha On eactt sample

' Gamma (e)

Monthly Composne St89 Semiannual Composite Sr 90 Semiannual Composite

  • Air lodine (5)

Weekly

  • l131 On each sample g.

(AI)

Air Tritium Weekly H3 On each sample g

(AT) i Precipitation Monthly Gamma (e)

On each sample (RW)

H3 On each sample l

Sr89 Semiannual Composne St90 Semiannual Composne

  • Milk [4]

Blweekly

  • l131 On each sample (M/MG)
  • Gamma (e)

On each sample Sr-89 Quarterly Composne

  • Fish [2](f)

Twice per year

  • Gamma (e)

On each sample (g)

(AOF)

(Spnno and Fall)

Sr 89 On each sample (g) j

  • St90 On each sample (g)

H3 On each sample (g).

l

  • Aquatic Sodimentl2)(h)

Twice per year

  • Gamma (c)

On each sample l

(.AOS)

(Spring and Fall)

Sr-89 On each sample l

Sr90 On each sample l

Biweekly (j) 1-131 Biweekly Composite

  • Surface Water (2)(if (SW)

(Composne)

  • Gamma (e)

Monthly Composne l

  • H -3 Monthly Composne l

Sr89 Semiannual Composne Sr-90 Semiannual Compostte l

E2-1 unso

FOR WFORMATION ONLY-

namue, Nuclear i EnWonmental Contr$

Policy and Procedure Manual 6615 PLN 4520.01 -

istle

% Sion No.

Radiological Environmental Monitoring Program Plan 1

EXHIBIT 2 (Cont'd)

TMINS REMP Sample Collection and Analysis by Media Sample Collection Analysis Analysis Medium (a)

Frecuenev(b)

Type (a)

- Frecuencv(b)

  • Drinking Water [2)(1)

Blweekly0)

  • l.131 BNyeekly Composite (SW)

(Composite)

'Gr Beta (k)

MontNy Composite

' Gamma (e)

MontNy Composite

  • H 3 Monthly Composite St-89 Semiannual Composne St 90 Semiannual Composite Effluent Weekly 0) 1131 Blweekly Composite (EW)

(Composrte)

Gr Beta MontNy Compostte.

H-3 MontNy Composite Gamma (e)

MontNy Compostte.

Sr89 Semiannual Composite St Semiannual Composne Aquatic Plants As needed Sr-89 On each sample (AQP)

' Sr 90 On each sample -

Gamma (e)

On each sample

' Vegetables [4]

Annually 1131 On each sample (g)

(FPV)

(at harvest)

  • Gamma (e)

On each sample (g)

St-89 On each sample (g) =.

St90 On each sample (g).

H3 On each sample (g)

' Fruits [4)

Annually

  • Gamma (e)

On each sample (g) -

(FPF)

(at harvest) 1131 On each sample (g).

Sr49 On each sampte(g)

St90 On each sample (g)

H-3 On each sample (g)

E2 2 m

__-_______________________._________L

  • T 301U,M90%f &

^

NumbDr

[r1 L Jl Nuclear

" roam *"ta' co'**$

Policy and Procedure Manual 6G15 PLN 4520.01 fitte Revision No.

Radiological Environmental Monitoring Program - Plan 1

EXHIBIT 2 (Cont'd)

TMINS REMP Sample Collection and Analysis by Media Sample Collection Analysis Analysis Medium (a)

Frecuencv(b)

Type (a)

Frequencv(b)

  • Green Leafy Vegetables /

Annually

  • l131 On each sample (g)

Vegetation [2)(h)

(at harvest)

  • Gamma (e)

On each sample (g)

(FPL)

Sr-89 On each sample (g)

  • Sr 90 On each sample (g)

H3 On each sampie(g)

  • Dosimeters (TLD)[40](1)

Quarterly

  • Gamma Quarterly (ID)

Immersion Dose Soll Twice per year Gamma (e)

On each sample (S)

(Spring and Fall)

Sr-89 On each sample Sr-90 On each sample Offsite Groundwater Monthly H3 On each sample (GW)

Gamma (e)

Quarterly composite Sr90 Quarterly composne Meat (Game)

Annually Gamma (e)

On each sample (g)

(GAD)

(as available)

Sr-89 On each sample (g)

Sr90 On each sample (g)

H3 On each sample (g)

  • Rodents As available Gamma On each sample (ROD) l l

E2-3 mu l

FOR INFORMATIDH OklY Numtyer M' L >1 Nuclear TMI Environmental Controls Policy and Procedure Manual 6615 PLN 4520.01 Tre Revissort No.

Radiological Environrnental Monitoring Program Plan 1

EXHIBIT 2 (Cont'd)

Table Notations a

Sample media and analyses denoted with an astensk(*) are reouired by the NRC. The number in the brackets following the sample medium indicates the minimum number of NRC required stations to be sampled. The locations (required by the NRC) from which sampies shall be collected are provided in the tables of the ODCM Deviations are permitted from the required sampling schedule if specimens (samples) are unobtainable due to hazardous conditions, seasonal unavailability, matfunction of automatic sampling equipment and other legitimate reasons All deviations from the sampling schedule shall be explained in the Annual Radiological Environmental Operating Report.

b The listed frequencies for collection and analysis of NRC required media meet or exceed the time intervals as spectfied by the NRC. A maximum allowable extension not to exceed 25% of the interval is permrtted.

However, the total maximum combined interval time for any 4 consecutive tests shall not exceed 3 25 times the speCffled Collection or analysis interval.

c.

Sample collection shall be weekly or more frequently if required by dust loading.

d.

Filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sample collection to allow for radon and thoron daughter decay, if the g*oss beta activity on an indicator filter is greater than 10 times the mean of the control samples, the indicator filter (s) shall be analyzed for Sr-90 and gamma-emrtting radionuchdes.

e.

Gamma (isotopic analysis) means the identification and quantification of gamma emitting radionuclides that may be attributable to the effluents from the facility.

f One sample of recreationally important bottom feeders arid one sample of recreationally important predators shall be collected in the vicinity of the plant discharge (indicator) and from an area not influenced t'y the plant discharge (control).

g Analysis shall be performed on the edible portion.

h Samples shall be collected at one indicator and one control locativt i.

Two samples (one indicator and one control) of surface water and drinking water shall be collected. The indicator surface water sample shall be collected downstream of the plant discharge in an area beyond but near the mixing zone. The indicator drinking water sample shall be collected at the nearest water supply that could be affected by the station discharge. The upstream (control) surface water and dnnking water samples shall be taken at a distance beyond significant influence of the plant discharge.

j Composite sample aliquots shall be collected at time intervals that are short (e g., hourty) relative to the composrting period in order to assure obtaining a representative sample. As necessary. a weokly composite sample will be analyzed to close out each quarterly sampling period.

E2-4 m

s

., i.ap4 Numbst

[r c il Nuclear M Ensonmental Contrds Policy and Procedure Manual 6615-PLN-4520.01 T tle FievisCr1 No.

i Radiological Environmental Monitoring Program - Plan 1

EXHIBIT 2 (Cont'd)

Table Notations k.

St 90 analysis shall be performed on the indicator drinking water sample (monthly composite) if the gross beta actrvity is greater than 10 times the control drinking water actmty.

1 At each location direct radiation shall be measured with either two dosimeters or one Instrument for continuously measuring and recording dose rate. A thermoluminescent dosimeter (TLD) is considered to be one phosphor; two or more phosphors in a packet are considered as two or more dosimeters. Film badges shall not be used.

l l

l l

E2 5 au l

.c FOR INFORMATION ONLY e

l Id r.N1 Nuclear 1 EnWronmental Controls Policy and Procedure Manual 6615 PLN-4520.01 Titie Revision No.

Radiological Environmental Monitoring Program - Plan 1

EXHIBIT 3 TMiNS REMP Regulatory Requirements / Guidance 1.

Three Mile Island Nuclear Station, Unit 1 Operating License No. DPR 50 Appencix A Technical Spectfications 2

Three Mile Island Nuclear Station. Unit 2 Operating Ucense No. DPR 73 Appendix B Technical Specifications 3

US Nuclear Regulatory Commission Regulatory Guide 1.16

" Reporting of Operating Information - Appendix A Technical Specifications

  • Revision 2 Sep 1974 4.

US Nuclear Regulatory Commission Regulatory Guide 1.21

' Measuring, Evaluating. and Reporting Radioactivity in Solid Wastes and Releases of Radioactrve Materials in Liquid and Gaseous Effluents from Ught - Water - Cooled Nuclear Power Plants", Revision 1 June 1974 5

U.S. Nuclear Regulatory Commission Regulatory Guide 4.1 Rev.1 April 1975 Prograhis for Monitoring fladioactivity in the Environs of Nuclear Power Plants 6.

U.S. Nuclear Regulatory Commission Regulatory Guide 4 2 Rev. 2 July 1976 Preparation of Environmental Reports for Nuclear Power Stations 7.

U.S. Nuclear Regulatory Commission Regulatory Guide 4.5 Rev. O May 1974 Measurements of Radionuclides in the Environment -

Sampling and Analysis of Plutonium.in Soil 8.

U.S. Nuclear Regulatory Commission Regulatory Guide 4.6 Rev. O May 1974 Measurements of Radienuclides in the Environment -

Strontium 89 and Strontium-90 Analyses 9.

U S. Nuclear Regulatory Commrssion Regulatory Guide 4.8 Rev. O Dec 1975 Environmental Technical Specifications for Nuclear Power Plants E3 t

=

a..

t,.

numo.,

[r g-)1 Nuclear

  • ' 5"*onmaa' cont'*

Policy and Procedure Manual 6615 PLN-4520.01 Titie F iston No Radiological Environmental Monitoring Program - Plan 1

EXHIBIT 3 (Cont'd) 10 U S. Nuclear Regulatory Commission Regulatory Guide 4.13 Rev.1 July 1977 Performance, Testing, and Procedural Speedications for Thermoruminescence Dosimetry: Environmental Applications 11.

U S. Nuclear Regulatory Commission Regulatory Guide 415 Rev.1 Feb 1979 Ouality Assurance for Radiological MonItonng Programs (Normal Operations) Effluent Streams and the Environment 12 U.S Nuclear Regulatory Commission Branch Technical Pos: tion on Regulatory Guide 4.8 Environmental Technical Specification for Nuclear Power Plants Revision 1, November 1979 13 U S. Nuclear Regulatory Commission NUREG4472. Rev. 3.1983 Standard Radiological Effluent Technical Specifications for Pressurized Water Reactors (Draft) 14.

TMINS Otisite Dose Calculation Manual (ODCM)

(Procedure 6610 PLN4200,01)

E3 2 mm

- _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ - _ _ _ _ _ _ _ - _ _ _ _ _ _ - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ - _ _ _ _