L 4.5.4- _ ACCIDENT RECIRCULATION SYSTEMS LEAKAGE Anolicability

- Applies to those portions of the Decay Heat, Building Spray, and Make-Up Systems, which are required to contain post accident sump recirculation fluid.

i Obiective -

[ To maintain a low leakage rate from the accident recirculation systems to prevent significant off-site l exposures.

i l Soecification _,

L 4.5.4.1 The total maximum allowable leakage from the applicable portions of the Decay L . Heat, Building Spray and Make-Up System components as measured during l - refueling tests m Specification 4.5.4.2 shall not exceed 15.0 gallons per hour.*

4.5.4.2 During each refueling interval the following tests of the applicable portions of the Decay Heat Removal, Building Spray and Make-Up Systems shall be conducted to determine leakage:

a. The applicable portion of the Decay Heat Removal System that is outside i

containment shall be leak tested with the Decay Heat pump operating or by hydrostatic testing at no less than 350 psig, except as specified m "b" b.- Piping from the Reactor Building Sump to the Building Spray pump and Decay Heat Removal System pump suction isolation valves shall be pressurc l tested at no less than 55 psig.

l l c. The applicable portion of the Building Spray system that is outside

- containment shall be leak tested with the Buildmg Spray pumps operating and BS-V-1 A/B closed or by hydrostatic testing at no less than 350 psig, except as i specified in "b".

L d. The applicable portion of the Make-Up system on the suction side of the l Make-Up pumps shall be leak tested with a Decay Heat pump operating and DH-V-7A/B open or hydrostatic testing at no less than 200 psig.

e. The applicable portion of the Make-Up system from the Make-Up pumps to

! the containment boundary shall be leak tested with a Make-Up pump )

operating or by hydrostatic test at no less than 3050 psig. j

f. Visual inspection shall be made for leakage from components of these systems. leakage shall be measured by collection and weighing or by another equivalent method

~

p *

- NOTE: This leal. rate limit is only applicable for the Cycle 13 operating cycle.

l i

Bases Ihe leakage rate limit of 15 gph (measured in standard cold gallons) for the accident recirculation

- portions of the Decay Heat Removal, Building Spray, and Make-Up Systems is based on ensuring that potential leakage after a loss-of-coolant accident will not result in off-site dose consequences in excess of those calculated to co aply with the 10 CFR 100 limits (Reference I and 2).

References . . .

(1) .UFSAR, Section 6.4.4 " Design Basis Leakage" and Table 6.4-3 " Leakage Quantities to the Auxiliary Building" (2) UFSAR, Section 14.2.2.5(d) " Effects of Engineered Safeguards Leakage During Maximum Hypothetical Accident" 4-45 Amendment No. M'/,20);

i i

l '

l UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION 1

IN THE MATTER OF DOCKET NO. 50-289 l l

GPU NUCLEAR, INC. LICENSE NO. DPR-50 CERTIFICATE OF SERVICE i

This is to certify that a copy of Technical Specification Change Request No. 274' Appendix A l Supplement of the Operating License for Three Mile Island Nuclear Station Unit 1, has, on the date given below, been filed with executives of Londonderry Township, Dauphin County, Pennsylvania, and the Pennsylvania Department of Environmental Resources, Bureau of '

Radiation Protection, by deposit in the United States mail, addressed as follows:

Dr. Edward Swartz, Chairman Ms. Sally S. Klein, Chairman Board of Supervisors, Londonderry Township Board of County Commissioners R. D. #1 Geyers Church Road Dauphin County Courthouse Middletown, PA 17057 Front and Second Streets Harrisburg,PA 17101 i

Director, Bureau of Radiation Protection PA Dept. of Environmental Resources Rachael Carson State Oflice Building P. O. Box 8469 Harrisburg, PA 17105-8469 ATTN: Mr. Stan Maingi GPU NUCLEAR, INC.

BY: I2M4 ye P,es,eent ane Di,ed' '"'

l DATE: ,8Q 9