6.'l 1 RADIATION PROTECTION PROGRAM I

Procedures for personnel radiation protection shall be prepared consistent with the requirements of 10 CFR Part 20 and shall be approved, maintained and adhered to for all operations involving persomiel radiation exposure.

6.12 HIGH RADIATION AREA 6.12.1 In lieu of the " control device" or " alarm signal" required by paragraph 20.1601 of 10 CFR 20:

a.

Each High Radiation Area in which the intensity of radiation at 30 cm (11.8 in.)

is greater than 100 mrem /hr. deep dose but less than 1000 mrem /hr. shall be barricaded and conspicuously posted as a High Radiation Area, and personnel

.iesiring entrance shall obtain a Radiation Work Permit (RWP). Any individual l

or group ofindividuals entering a High Radiation Area shall (a) use a l

continuously indicating dose rate monitoring device or (b) use a radiation dose rate integrating device which alarms at a pre-set dose level (entry into such arear with this monitoring device may be made aner the dose rate level in the area has been established and personnel have been made knowledgeable of them), or (c) assure that a radiological control technician provides positive control over activities within the area and periodic radiation surveillance with a dose rate monitoring instrument.

b.

In addition to the requirements of specification 6.12.1.a:

l

1. Any area accessible to personnel where an individual could receive in any one hour a deep dose in excess of 1000 mrem at 30 cm (11.8 in.) but less l

than 500 rads at one meter (3.28 n.) from sources of radioactivity shall be locked or guarded to prevent unauthorized entry. The keys to these locked barricades shall be maintained under the administrative control of the respective Radiological Controls Supervisor.

2. For individual high radiation areas where an individual could receive in any one hour a deep dose in excess of 1000 mrem at 30 cm (11.8 in.) but less than 500 rads at one meter (3.28 ft.), that are located within large areas such as reactor containment, where no enclosure exists for purposes of locking, and where no enclosure can be reasonably constmeted around the individual area, that individual area shall be barricaded and conspicuously posted, and a flashing light shall be activated as a warning device.

The Radiation Work Permit is not required by Radiological Cont.ols personnel during the performance of their assigned radiation protection duties provided they are following radiological control procedures for entry into High Radiation Areas.

6-22 Amendment Nos. !!, 25, 72, 77dO6;407,-129,173,180; J

Certificate of Service for TMI-l Technical Specification Change Request No. 273 l

1

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION IN THE MATTER OF GPU NUCLEAR, Inc.

,,., i DOCKET NO. 50-289 LICENSE NO. DPR-50 CERTIFICATE OF SERVICE This is to certify that a copy of Technical Specification Change Request No. 273 to Appendix

' A of the Operating License for Three Mile Island Nuclear Station Unit 1, has, on the date given below, been filed with executives of Londonderry Township, Dauphin County, Pennsylvania; Dauphin County, Pennsylvania; and the Pennsylvania Depanment of Environmental Resources, Bureau of Radiation Protection, by deposit in the United States mail, addressed as follows:

Mr. Darryl LeHew, Chairman Ms. Sally S. Klein, Chairman i

Board of Supervisors of Board of County Commissioners Londonderry Township of Dauphin County j

R.D. #1, Geyers Church Road Dauphin County Courthouse Middletown, PA 17057 Harrisburg, PA 17120 t

Dimetor, Bureau of Radiation Protection.

f PA Department of Environmental Resources Rachel Carson State Office Building -

P.O. Box 8469 Harrisburg, PA 17105-8469

' ATTN: Mr. Stan T. Maingi GPU NUCLEAR, Inc.

I belM.

BY:

VWe President and Di ec or, TMI 6///!98 DATE:

i l

l

-