USNRC 6.0 ADMINISTRATIVE CONTROLS f 6.1 ORGANIZATION '% Jll 10 A9 :47
- n. The organization for the manageme dg g of the reactor shall be as indicated re The Director, Nuclear Research Center [aball ,
responsibility. for direction and oper on of the reactor' facility, including safeguarding the general '
public and facility personnel from radiation exposure and adhering to all requirements of the operating ,
license and Technical Specifications.
- b. The Manager, Office of Radiation Safety, shall advise the Director, Nuclear Research Center in ' matters pertaining to radiological safety at the GTRR. She/he '
has access to the Vice President, Interdisciplinary Programs and/or the President of the Institute as needed. ,
- c. The minimum qualf 1 cations with regard to education and ,
experience backgrounds of key supervisory personnel in the Reactor Operations group shall be as follows: ;
. (1) iteactor Suoervisor l The Reactor Supervisor must have a college degree l or equivalent ~ in specialized training and J spplicable experience, and at least five years experience in a responsible position in reactor operations.or related fields including at least l one year experience in reactor facility management or supervision. He shall hold a Senior Reactor Operator's license for the GTRR.
(2) Reactor Encinear l
The Reactor Engineer must have a combined total of at least seven years of college level education and/or nuclear reactor experience with at least three-years -experience in reactor operations or related fields. He shall be !
qualified to hold a Senior Reactor Operator's I license.
- d. Senior Reactor Operator's License f Whenever the reactor is not secured, the minimum crew l complement at the facility shall be two persons, !
4 including at least one cenior operator licensed ;
i pursuant to 10 CFR 55.
I NUCLEAR REGULATORY COMMISSION Docket No So -/ (s, c- 4.6 /0 EXHIBIT NO. 30 in the rnatter ofM Q 9607180095 960530 7 O Staff ErApplicant O intervenor O other PDR ADOCK 05000160 (21dentified @eceived O Rejected Reporter w L. ul
, g l PDR o,,, 3 l3 c.) u witness
l 41 Office of the President Office of the Nuclear Vice President Safeguards for Committee Interdisciplinary Programs i
I !
I I
Reporting (Safety l (& Safety policy) i Office of the g NNRC Director Supervisor, Admin. Reporting Manager of Manager of Coordinator of Manager, Office Reactor Gamma Radiation Experimental of Radiation Operations Operations Research Safety l
l l
l l
Figure-6.1 Georgia Tech Organization for Management and l I
Operation of GTRR.
l
42
- e. An operator or senior operator licensed pursuant to 10 CFR 55 shall be present at the controls unless the reactor is shutdown as defined in these specifications.
6.2 NUCLEAR SAFEGUARDS COMMITTEE
- a. A Nuclear Safeguards Committee shall be established by the President of the Institute and shall be responsible for maintaining health and safety standards associated with operation of the reactor and its associated facilities.
- b. The Committee shall be composed of five or more senior technical personnel who collectively provide experience in reactor engineering, reactor operations, chemistry and radiochemistry, instrumentation and control systems, radiological safety, radiation protection, and i mechanical and electrical systems. No more than a l minority of the Committee members shall be from the GTRR staff.
- c. The Committee shall meet quarterly and as circumstances warrant. Written records of the proceedings, including any- recommendations or occurrences, shall be distributed to all Committee members and the President's Office,
- d. The quorum shall consist of not less than a majority of the Committee membership and shall include the chairman or his designated alternate. The operating staff may ;
! not constitute a majority of those present. l
- e. The Committee shall:
, (1) Review and approve proposed changes in equipment, j l systems, tests, experiments, or procedures that ;
do not involve an unreviewed safety question i I
pursuant to 10 CFR 50.59(a).
(2) Review reportable occurrences. I (3) Review and approve proposed operating procedures and proposed changes to operating procedures. ;
Minor modifications to operating procedures which ;
do not change the original intent of the operating procedure may be approved by the Director of NNRC on a temporary basis. The Committee shall consider for approval such minor
- modifications at its next scheduled meeting.
(4) Review and approve proposed changes to Technical Specifications and license excluding organizational structure. The responsibility and authority for organizational structure resides with the President of the Institute.
43 (5) Review and approve proposed experiments and tests utilizing the reactor facility which are significantly different from tests and experiments previously performed at the GTRR.
(6) Review and approve proposed changes to the facility made pursuant to 10 CFR 50.59(c).
(7) Review violations of Technical Specifications, license, or internal procedures or instructions having safety significance.
(8) Review operating abnormalities having safety !
significance. ,
1 (9) Review audit reports.
(10) Audit reactor operations and reactor operation records for compliance with internal rules, procedures, and regulations and with licensed provisions including Technical Specifications at least once per calendar year (interval between audits not to exceed 15 months).
(11) Audit the retraining and re-qualification program for the operating staff, at least once every other calendar year (interval between audits not to exceed 30 months).
(12) Audit the results of action taken to correct those deficiencies that may occur in the reactor facility equipment, systems, structures, or methods of operations that affect reactor safety, at least once per calendar year (interval between audits not to exceed 15 months).
6.3 ADMINISTRATIVE CONTROLS OF EXPERIMENTS
- a. Evaluation by Safety Review Group (1) No experiment shall be performed without review and approval by the Nuclear Safeguards Committee.
Repetitive experiments with common safety considerations may be reviewed and approved as a class.
~
(2) Criteria for review of an experiment or class of experiments shall include (a) applicable regulatory positions including those in 10 CFR Part 20 and the technical specifications and (b) in-house safety criteria and rules which have been established for facility operations, including those which govern requirements for encapsulation, venting, filtration, shielding,
44 and similar experiment design considerations, as well as those which govern the quality assurance program required under 50.34.
(3) Records shall be kept of the Nuclear Safeguards Committee's review and authorization for each experiment or class of experiments,
- b. Operations Acoroval (1) Every experiment shall have the prior explicit written approval of the Neely Nuclear Research Center management including the Reactor Supervisor.
- c. Procedures for Active Conduct of Exoeriments (1) Written procedures shall be provided for the use or operation of experimental facilities.
(2) While the reactor is operating, no experiment j shall.be moved without permission of the licensed ,
operator at the console.
(3) Each experiment removed from the reactor or reactor system shall be subject to a_ radiation survey which anticipates exposure rates greater than those predicted, n.n ~ ..
.. j
- d. Procedures Relatina to Personnel Access to Exoeriments (1) There shall be a documented procedure for the control of visitor access to the reactor area to minbnize the likelihood of unnecessary exposure to radiation as a result of ongoing activities.
~
- e. Quality Assurance Procram-There shall be a Quality Assurance Program covering the fabrication, and testing of experiments,
~
design, including procedures for verification of kinds and amounts of their material contents to assure compliance with the technical' specifications in Section 3.4.
. . - _ _ _ _ _ . , )
.- --- -. . . . - . ._--~ .- .- .- .- - .. .
45 ,
6.4 PROCEDURES 6
- a. All procedures and major changes thereto shall be reviewed and approved by the Nuclear Safeguards J Committee prior to being effective. Changes which do not alter the original intent of a procedure may be 7 approved by theprector of the facility Such changes shall be recorded and submitted period cally to the .
Nuclear Safeguards Committee for routine review. I et LG 6%AC
- b. Written procedures shall be provided and utilized for j the following:
7 (1) Neenea- A f artup, operation and shutdown of the reactor and of all systems and components involving nuclear safety of the system.
(2) Installation and removal of fuel elements, control Medes , experiments and experimental facilities. 4 ,4 (3) Actions to be taken to correct specific and foreseen potential malfunctions of systems or components, including responses to alarms, suspected primary system leaks and abnormal reactivity changes.
(4) Emergency conditions involving potential or actual release of radioactivity.
(5) Preventive or corrective maintenance operations which could have an effect on the safety of the reactor.
(6) Radiation and radioactive contamination control.
i (7) Surveillance and testing requirements.
(8) A site emergency plan delineating the action to be taken in the event of emergency conditions and accidents which result in or could lead to the.
, release of radioactive materials in quantities j that could endanger the health and safety of ;
employees or the public. Periodic evacuation drills for facility personnel shall be conducted to assure that facility personnel are familiar with the emergency plan.
i (9) Physical security of the facility and associated special nuclear material. !
- 6.5 OPERATING RECORDS
. a. The following records and logs shall be prepared and retained at the facility for at least five years:
l
46 (1) Normal facility operation and maintenance.
(2) Reportable occurrences.
- f. (3) Tests, checks, and measurements documenting l compliance with surveillance requirements. ,
1 l (4) Records of experiments performed.
- b. The following records and logs shall be prepared and retained at the facility for the life of the facility:
(1) Gaseous and liquid waste released to the L
environs.
l (2) offaite environmental monitoring surveys.
! (3) Radiation exposures for all GTRR personnel.
1 (4) Fuel inventories and transfers.
(5) Facility radiation and contamination surveys.
l (6) Updated, corrected, and as-built facility l drawings.
(7) Minutes of Nuclear Safeguards Committee meetings.
i (8) Records of radioactive shipments.
! 6.6 ACTION TO BE TAKEN IN THE EVENT OF A REPORTABLE OCCURRENCE
! In the event of a reportable occurrence, as defined in these l Technical Specifications, the following action shall be takens-l
- a. Reactor conditions shall be returned to normal or the-reactor shall be shutdown. If it is necessary to shut l the reactor down to correct the occurrence, operations l shall not be resumed unless authorized by the director of the facility.
- b. All reportable occurrences shall be promptly reported j to the reactor supervisor and the director of the !
facility. l
- c. All reportable occurrences shall be reported to the Nuclear Regulatory Commission in accordance with Section 6.7 of these specifications.
l
! d. All-reportable occurrences shall be revieyed b the l Nuclear Safeguards Committee d M O *- p r se eddeE 1
( ew M
__ . _ _ _ _ . , _ . ...i
47 6.7 REPORTING REOUIREMENTS The following information shall be submitted to the USNRC in addition to the reports required by Title 10, Code of Federal Regulations.
- a. Annual Ooeratina ReDorts A report covering the previous year shall be submitted to the of fice of the Regional Administrator, Region II, with a copy to the Director, Office of Nuclear Reactor Regulation, by March 1 of each year. It shall include the following:
(1) Operations Summgat A summary of operating experience occurring during the reporting period including (a) changes in facility design; (b) performance characteristics (e.g. , equipment and fuel performance);
(c) changes in operating procedures which relate to the safety of facility operations; (d) results of surveillance tests and inspections required by these technical i
specifications; l
(e) a brief summary of these changes, tests, and experiments which required authorization l
from the Commission pursuant to 10 CFR 50.59(a), and (f) changes in the plant operating staff serving j in the following positions:
1 Director, Nuclear Research Center
- 2. Reactor Supervisor
, 1 Reactor Engineer l
( 1 Manager, Office of Radiation Safety l ~
! 5. Nuclear Safeguards Committee members I
i-4 l:
i
L. .
i 48 i
(2) Power Generation A tabulation of the thermal output of the facility during the reporting period.
(3) Shutdowns A listing of unscheduled shutdowns which have occurred during the reporting period, tabulated l
according to cause, and a brief discussion of the >
preventive actions taken to prevent recurrence.
(4) Maintenance A discussion of corrective maintenance (excluding preventative maintenance) performed during the ;
reporting period on safety related systems and components.
(5) Chances, Tests and Experiments I A brief description and a summary of the safety J evaluation for those changes, tests, and ;
experiments which were carried out without prior Commission approval, pursuant to the requirements of 10 CFR Part 50.59(b).
(6) Radioactive Effluent Releases A statement of the quantities of radioactive effluents released from the plant, with data summarized following the general format of USNRC Regulatory Guide 1.21:
(a) Easeous Effluents
- 1. Gross Radioactivity Releases
- a. Total gross radioactivity (in curies), primarily noble and activation gases.
- b. Average concentration of gaseous effluents released during normal l steady state operation. (Averaged I over the period of reactor operation.)
- c. Maximum instantaneous f concentration of gaseous radionuclides released during special operations, tests, or l
49 experiments, such as beam tube experiments, or pneumatic . tube operation.
- d. Percent of technical specification :
limit. i i
1 Iodine Releases (Required if iodine is identified 'in primary coolant samples, isotopic ;
analysis required in (a)1. above'or if i fueled experiments are conducted at the facility.)
A. Total iodine radioactivity (in curies) by nuclide released, based ,
on representative isotopic analyses performed.
- h. Percent of technical specification limit. ,
J. Particulate Releases ;
A. Total gross radioactivity (p,y) '
released (in curies) excluding ,
background radioactivity.
- h. Gross alphi adioactivity released (in curis , excluding background .
radioactiviLy. (Required if the operational' or - experimental ;
program could result in the release of alpha emitters.)
- g. Total gross radioactivity (in curies) of nuclides with half- i lives greater than eight days. [
- d. Percent of Ef fluent Concentration, as listed in 10 CFR 20, Appendix
{ B, Table 2, Column 1, for particulate radioactivity with 5 half-lives- greater days.
than eight
' [
(b) Licuid Effluents I
l 1. Total gross radioactivity (p,y) !
! released (in curies) excluding tritium ;
,f and average concentration released 'to ;
7 :
i
50 the unrcotricted crea or scnitary scwsr (averaged over period of release).
2 The maximum concentration of gross radioactivity (p,y) released to the unrestricted area.
2 Total alpha radioactivity (in curies) released and average concentration released to the unrestricted area (averaged over the period of release).
1 Total volume (in al) of liquid waste released.
1 Total volume (in al) of water used to dilute the liquid waste during the ;
period of release prior to release from '
the restricted area.
1 Total radioactivity (in curies), and .
concentration (averaged over the period 4 of release) by nuclide released, based on representative isotopic analyses performed for any release which exceeds 1 x 10-' yC1/ml.
2 Percent of technical specification limit for total radioactivity released from the site. !
(7) Environmental Monitorinc ;
For each medium sampled, e.g., air, surface water, soil, fish, vegetation, includes i (a) Number of sampling locations and a j description of their location relative to ;
the reactor. i (b) Total number of samples. 1 (c) Number of locations at _ which levels are ,
found to be significantly above local i backgrounds.
1 (d) Highest, lowest, and the annual average l concentrations or levels of radiation for
, the sampling point with the highest average and the location of that point with respect to the site.
b h
h
- .e 1 r
51 !
(o) Ths maximum cumulativa radiation dose which j could have been received by an individual ;
continuously present in an unrestricted area j during reactor operation from: ;
i 1 direct radiation and gaseous effluent, }
r 1 liquid effluent. !
If levels of radioactive materials in (
environmental media, as determined by an ;
environmental monitoring program, indicate j the likelihood of public intakes in excess 1 of 1% of those that could result from i continuous exposure to the concentration !
values listed in Appendix B, Table 2, 10 CFR l Part 20, estimates of the likely resultant exposure to individuals and to population groups and assumptions upon which estimates j are based shall be provided.
(8) Occuoationa1 Personnel-Radiation Exoosure A summary of radiation exposures greater than 500 i mrem (50 mrem for persons under 18 years of age) received during the reporting period by facility personnel (faculty, students, or experiments). ;
I j b. Non-Routine Reoorts (1) Reportable Occurrence Reports Notification shall be made within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by '
telephone and telegraph . to the Office of the regional Administrator, Region II, with a copy to the Director, . Office of Nuclear Reactor Regulations followed by a written report witlii .
10 days to the Office of the regional Administrator, Region II, with a copy to the '
7(.! Director, Office of Nuclear Reactor Regulations gM $
l in the event .of the reportable occurrences as defined in section 1.0. The written report on
[ {. g g these reportable occurrences, and to the extent goG
\ s/
v possible, the preliminary telephone and telegraph notification shall:
bW (a) describe, analyze, and evaluate safety implications,
~
l (b) outline the measures taken to assure that the cause of the condition is determined,
- c. .
&v 1 . .- -
52 :
(c) indicato thm correctiva action (including >
any changes made to the procedures and to the quality assurance program) taken to ,
prevent repetition of the occurrence and of -
similar occurrences involving similar ,
components or systems, and (d) evaluate the safety implications of the incident in light of the cumulative
- experience obtained from the record of previous failures and malfunctions of '
similar systems and components.
(2) Unusual Events
{
t A written report shall be forwarded within 30 i days to the Office of the Regional Administrator, i Region II, with a copy to the Director, Office of Nuclear Reactor Regulations in the event of:
L (a) Discovery of any substantial errors in the transient or accident analyses or in the i methods used for such analyses, as described l in the Safety Analysis Report or in the i bases for the Technical Specifications. :
, (b) Discovery of any substantial variance from l
- performance specifications contained in the !
Technical Specifications or in the Safety i Analysis Report. ,
(c) Discovery of any condition involving a l possible single failure which, for a system i designed against assumed single failures, could result in a loss of the capability of the system to perform its safety function.
i l i