ML20092C328
| ML20092C328 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 09/06/1995 |
| From: | Shell R TENNESSEE VALLEY AUTHORITY |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 9509120350 | |
| Download: ML20092C328 (7) | |
Text
,
. En Tennessee Vaney Authonty Post Offce Box 7J00. Soody-Daisy Tennessee 37379 September 6,1995 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:
In the Matter of
)
Docket Nos. 50-327 Tennessee Valley Authority
)
50-328 SEQUOYAH NUCLEAR PLANT (SON)- 10 CFR 50.46 UPDATED ANNUAL REPORT
Reference:
TVA letter to NRC dated July 12,1995, "Sequoyah Nuclear Plant (SON) -
10 CFR 50.46 Annual Report" 10 CFR 50.46 requires that a 30-day report be furnished if a significant change in peak clad temperatureis discovered. The purpose of this letteris to provide this notification. Recently, Westinghouse Electric Corporation withdrew its request for NRC approval of the Power Shapes Sensitivity Model (PSSM). PSSM had been developed and submitted to NRC as a statistical methodology to evaluate and assure that the cosine distribution remains the limiting distribution. This methodology was implerriented on a forward-fit tiasis. In order to rninimize potential peak clad temperature (PCT) penalties due to the withdrawal of PSSM, Westinghouse developed an alternate axial power shape methodology, Explicit Shape Analysis for PCT Effects.
i The Explicit Shape Analysis for PCT Effects methodologyis based on explicit analysis of a set of skewed axial power shapes. The explicit use of skewed power shapes has previously been approved by NRC as part of the Westinghouse large break loss-of-coolant accident (LOCA) evaluation model. Based upon this replacement, the SON large break LOCA analysis is impacted in the form of a penalty.
To offset the effect of the skewed power shapes discussed above, it was necessary to mod 61 an improvement to the large break LOCA evaluation model for plants with a severe penality. TVA decided to apply this improvement to its large break LOCA evaluation model. This improvement allows for the modeling of flow through the hot-leg nozzle gap as a benefit. This benefit is cuained by including steam flow through the reactor vessel hot-leg nozzle gap (between the core barrel and the reactor vessel) in the calculations.
11008V h'
9509120350 950906 PDR ADDCK 05000327
__R.
__ PDR I
~.
k t
U.S. Nuclear Regulatory Commission Page 2 September 6,1995 An additional benefit is derived by eliminating the penalty that has been assessed against the large break LOCA evaluation model for the Westinghouse standard fuel j
assembly with Inconel grids. Since Cycle 5, most of the standard fuel assemblies j
have been replaced with Vantage-5H assemblies with Z rcaloy grids. The few standard fuel assemblies that have not been replaced will continue to be located in l
low power regions. By ensuring the standard fuel assemblies remain in low power region, the relative average power factor for the Vantage-5H fuel assemblies is bounding. The reload safety analysis process will ensure that the remaining ctandard fuel assemblies will remain in the low power regions for future cycles.
The summation of the PCT impact from the above three items results in a 245 degrees Fahrenheit ( F) decrease in the large break LOCA PCT, which exceeds the threshold discussed in 10 CFR 50.46 (a)(3)(ii). Additionally, the above-identified changes do not result in exceeding the limits of 10 CFR 50.46, and PCT margin allocations will ensure these limitations are not exceeded. Therefore, further reanalysis or actions are not planned at this time.
i The attached enclosure provides the benefits and penalty discussed above. The above reference provided SON's 1995 Annual 10 CFR 50.46 Report. The small break l
LOCA PCT remains unchanged from that reported in the referenced document.
Additionally, potentialissues are under investigation by Westinghouse thet may l
impact the PCT for large and small break LOCA. The potentialissues have had PCT margin temporarily allocated to ensure that the cumulative efforts are tracked such that the 10 CFR 50.46 PCT limit of 2200 Fis not exceeded. Upon their resolution, these issues will continue to be reported as appropriate.
Please direct questions concerning this issue to W. C. Ludwig at 843-7460.
Sincerely,
- h. Y-R. H. Shell Manager SON Site Licensing Enclosure cc: See page 3 e
i U. S Nuclear Regulatory Commission Page 3 September 6,1995 cc (Enclosure):
Mr. D. E. LaBarge, Project Manager Nuclear Regulatory Commission i
One White Flint, North -
11555 Rockville Pike Rockville, Maryland 20852-2739 NRC Resident inspector Sequoyah Nuclear Plant i
2600 Igou Feny Road Soddy-Daisy, Tennessee 37379 3624 Regional Administrator U.S. Nuclear Regulatory Commission Region 11 101 Marietta Street, NW, Suite 2900 i
Atlanta, Georgia 30323-2711
[
+
I i
ENCLOSURE 10 CFR 50.46 REPORT DOCUMENTATION i
3
'Laras Break Loss-of-Coolant Accident (LOCA) e ECI Attachment t
Previous Licensing Basis Peak 2156*F
. Cladding Temperature (PCT)
(July 12,1995)
Standard Fuel Assembly Relative Average
-100 F 1
Power Limit Adjustment l
ESHAPE' Power Shape Sensitivity Model
+25 F 2
l Hot Leg Nozzle Gap Flow Modeling
-170 F 3
l Updated Licensing Basis PCT 1911 F t
Net Change
-245 F i
Small Break LOCA i
ECI I
j Previous Licensing Basis PCT 1716*F (July 12,1995)
No Change Idontified 0F Updated Licensing Basis PCT 1716 F Net Change 0F I
I A detailed discussion of the change outlined above is included in the indicated attachment.
- Explicit EHape analysis for ECT Effects
STANDARD FUEL ASSEMBLY RELATIVE AVERAGE POWER ADJUSTMENT
Background
The current licensing basis large break loss-of-coolant accident for Sequoyah was performed using the 1981 Westinghouse ECCS Evaluation Model (BASH). The analysis was performed to support operation with a peaking factor (F) of 2.40, a hot channel factor (FJ of 1.62 and a relative average power factor (PJ of 1.44. This analysis was initially performed for the Westinghouse Standard Fuel Assembly with Inconel grids. Begmnmg with Unit 1, Cycle 5 operation, TVA began using the Westinghouse Vantage-5H Fuel Assembly with Zircaloy grids.
The analysis performed to support use of the Vantage-5H fuel found that the original Standard fuel assembly results bounded the Vantage-5H results. As such, no change to the ECCS evaluation model or calculated peak clad temperature was required to support use of the Vantage-5H fuel assemblies.
Since Cycle 5, most of the Standard fuel assemblies at Sequoyah have been replaced with Vantage-5H assemblies. The Standard fuel assemblies which continue to be in operation in the present (and future) cores are located in low power regions (typically on the periphery of the core). As a result, the relative average power of these assemblies is much lower than the 1.44 value assumed in the licensing basis analysis. At the request of TVA, Westinghouse recently performed an evaluation to determine the maximum allowable average power factor for the Standard fuel assemblies which would result in a peak clad temperature less than that previously calculated for Vantage-5H fuel assemblies. The evaluation found that limiting the Standard fuel relative average power factor to 1.28 will ensure that the Vantage-5H results are bounding.
A review of the Standard fuel assemblies presently installed at Sequoyah (and future core designs for Cycle 8 operatinn) found that they meet the 1.28 relative average power factor limit. As such, TVA has decided to impose a permanent relative average power limit of 1.28 on all Sequoyah Standard fuel assemblies. This limit will be evaluated as part of the reload safety evaluation process for all future cores designed under the present large break loss-of-coolant accident en*]ysis. This limit will allow the Vantage-5H fuel assembly analysis to be adopted as the Sequoyah licensing basis analysis.
Estimated Effect The calculated peak clad temperature for the Standard fuel assemblies exceeds that calculated for the Vantage-5H fuel assemblies by 100 F for a relative average power factor of 1.44. Limiting the remaining Standard fuel assemblies to a relative average power factor of 1.28 will result in a 100 F reduction in calculated peak clad temperature.
l
.~
4 i
ESHAPE POWER SHAPE SENSITIVIIT MODEL
)
Background
5 Large break loss-of-coolant accident analyses generally assume a symmetric, chopped cosine, 3
j core axial power distribution. Under cenain conditions, there is a potential for top-skewed power distributions to result in peak clad temperatures greater than those calculated with the chopped -
I cosine power distribution. In 1991, Westinghouse developed a statistical methodology to evaluate and assure that the cosine distribution is the limiting power distribution. This methodology is referred to as the power shape sensitivity model (PSSM) and is documented in Topical Report WCAP-12909-P. This methodology has been used to suppon the Sequoyah core reload safety l
cvaluations for the present fuel cycles (Cycle 7).
f Based upon recent NRC concerns regarding the statistical apr wh and uncertainties used in the-i PSSM methodology, Westinghouse has indicated that the PSSM methodology has been replaced i
by an alternate evaluation methodology for the BASH emergency core cooling system evaluation model. This alternate methodology is referred to as ESHAPE (Explicit Shape Analysis for PCT l
Effects) and has been approved by NRC as pan of the Westinghouse large break loss-of-coolant 1
j accident evaluation model (Topical Report WCAP-10266-P-A, Addendum 1, Revision 2-P-A).
This methodology is based upon explicit analysis of a set of skewed power shapes.
i
(
Estimated Effect l
[,,
Westinghouse has performed an evaluation of the Sequoyah large break loss-of-coolant accident N
using the'aSHAPE methodology. The revised axial power distribution model increased the l
calculated peak clad temperature by 25*F.
1 e
I
]
1 4
1 i
i i
HOT LEG NOZZLE GAP FLOW MODELING
Background
Westinghouse designed pressurized water reactors have a small gap at the interface between the reactor core barrel and the reactor vessel at the hot leg nozzle location. This gap is necessary for installing and removing the core barrel. This gap creates a flow path for core cooling during a large break loss of-coolant accident from the upper plenum to the cold leg via the downcomer region. No credit is taken for this flow path in the present Sequoyah large break loss-of-cooling accident analysis.
Westinghouse has recently developed a methodology for modeling these gaps in the BASH emergency core cooling system evaluation model. This methodology is documented in Topical Report WCAP-14404-P. This modification extends the basic flow link modeling of the existing evaluation model to the additional flowpath created by the hot leg gaps. This modeling enhancement has recently been applied to the Sequoyah large break loss-of-coolant accident analysis.
Estimated Effect Application of the hot leg nozzle gap flow modeling to the Sequoyah large break loss-of-coolant accident analysis reduces the calculated peak clad temperature by 170 F.
s
%