ML20084D403
| ML20084D403 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 07/29/1974 |
| From: | Robert E. Uhrig FLORIDA POWER & LIGHT CO. |
| To: | Anthony Giambusso US ATOMIC ENERGY COMMISSION (AEC) |
| Shared Package | |
| ML20084D330 | List: |
| References | |
| NUDOCS 8304110160 | |
| Download: ML20084D403 (1) | |
Text
h
~
w P. O. BOX 013103, MtAMI, FLCR!DA 33101
,pg
,!'$$$ h % f U
.J t.a x-f FLOR:OA PO'/iER & LIGHT CO*.*P A'eY July 29, 1974 f-i.i s\\
2 e
h Mr.'Angelo Giambusso
-Q' Deputy Director for Reactor Projects
' k,f
.a
\\g,\\
Directorate of Licensing SJ
%()
.,ffh j7"o b kd Office of Regulation E
j v
EA dirMn'[f4 h'-
U.
S.
Atomic Energy Commission M
Washington, D.
C.
20545 G Q#
M<k i
Dear Mr. Giambusso:
Ca
< tu.s Re:
Turkey Point Unit No. 4 Docket No. 50-251 Inspection of Safety Related Ilydraulic Pipe Restraints Inspection of the fifteen Bergen-Patterson safety related pipe restraints that are accessible during power operation was completed on July 12, 1974, in accordance with the con-tinuing requirements of the Atomic Energy Commission Direc-Lviate of Licca. slaw i c L L e r o f I;s','un i c z 0, 1973.
The i-.cpcc -
tion showed that all of the restraints were operable.
Very truly yours, Robert E.
Uhrig Vice President REU:nch cc:
Mr. Norman C.
Moseley Mr. Jack R. Newman 1h A
{
\\
{ :. I t
\\{ bVj f,)
I.
'\\j 80/10 8304110160 741024 PDR ADOCK 05000251 G
PDR s-COPY SENT REGION k
_