ML20072Q102

From kanterella
Jump to navigation Jump to search
Follow-up Emergency Notice of Reportable Superfund Amends & Reauthorization Act Release:On 940726,approx 33 Lb of Hydrazine Released to Environ.Special Drum Hand Truck Ordered & Appropriate Personnel Trained on Proper Use
ML20072Q102
Person / Time
Site: Mcguire, McGuire  Duke Energy icon.png
Issue date: 08/25/1994
From: Mcmeekin T
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9409090125
Download: ML20072Q102 (3)


Text

, .

Il I Duke kwer Company T C hichfam Af:Cuire Nudear Generation Department Ske President 1 12700Hagers Ferry Road (31GoltP) (T04)87%S00 ,

Huntemnile. NC28078&983 (704)8754809 Fax j DUKEPOWER August 25, 1994 Docuracnt Control Desk U. S. Nucicar Regulatory Commission Washington, D. C. 20555

Subject:

McGuire Nuclear Station Superfund Amendments and re authorization Act (SARA)

Follow-up Release Notification Gentlemen:

Pursuant of 40CFR Part 355 (Emergency Planning and Notification), Duke Power Company, McGuire Nuclear Station hereby provides follow-up written notification of a reportable SARA release. Notification q was made on July 26,1994 to the Regional Oflice of the Nuclear Regulatory Commission as required by l 10CFR50.72 (B)2(vi) within four (4) hours of the determination that the incident was reportable.

Very truly yours,

/d v T. C. McMeck.'n xc: Mr. S. D. Ebneter

. Administrator, Region 11 U.S. Nuclear Regulatory Commission 101 Marietta St. NW, Suite 2900 Atlanta, Ga. 30323 Mr. Victor Nerses U. S. Nuclear Regulatory Commission Office of Nuclear Regulatory Commission Washington, D. C. 20555 Mr. G. F. Maxwell NRC Resident inspector McGuire Nuclear Station U. S. Nuclear Regulatory Commission

/

' /- ,.,,.._ . g-bbbk $8@Ol69 PDR in w w,uma.

5

. Duke Iburr Company (704)875-4000

    • McGuire Nuclear Station 12700 Hagers feny Road Hantersci!!e, NC5078 l DUKEPOWER

~

August 3,1994 North Carolina Emergency Response Commission Mr. Billy Ray Cameron, Chairman 116 West Jones Street Raleigh, NC 27603-1335 Charlotte-Mecklenburg Emergency Management Office Mr. Wayne Broome, Director 125 South Davidson Street Charlotte, NC 28202

Subject:

McGuire Nuclear Site Superfund Amendments and Reauthorization Act (SARA)

Fo'!ow-up Release Notification

Dear Sirs:

Pursuant to 40CFR Part 355 (Emergency Planning and Notification), Duke Power Company, McGuire Nuclear Station hereby provides written fol'3w-u/ emergency notice of a reporteble SARA release. On July 26,1994 at 8:30 am, approximately 33 pounds of hydrazine, a SARA Extremely Hazardous Substance, was released to the environment. Hydrazine has a reportable quantity (RO) of one (1) pound.

The duration of the release was approximately 90 minutes. Verbal notifications were made to your offices on July 26,1994, as well as to the National Response Cenler (NRC). The NRC incident number is 251810 The North Carolina Department of Environment, Health, and Natural Resources Regional Office in Mooresville was also notified. Additionaliy, a notification was made to the Regional Office of the Nuclear Regulatory Commission as required by 10CFR50.72 (b)2(vi) within four (4) hours of the determination that the incident was reportable.

The hydrazine release occurred when an employee accidently punctured the bottom of a plastic 55 gallon drum when he attempted to move it with a drum hand truck. The hydrazine was at a concentration of 54.4%. Approximately 15 gallons of hydrazine spilled to the asphalt. The release was contained on the asphalt area, with none reaching any soil or water areas. It was calculated that approximately 33 pounds of hydrazine vola'ilized, before the spill was completely cleaned up,90 minutes later.

Remedial actions consisted of taping off the area and keeping personnel away. The McGuire Site HazMat Team responded to stop the release and clean up the hydrazine from the asphalt. The leaking drum was overpacked, and oil dri was used to clean up the spilled liquid.

There are no known or anticipated health risks associated with this release. The Material Safety Data Sheet (MSDS) was consulted before attempting any remediation. The HazMat Team was fully " dressed out' including self-contained breathing apparatus (SCBA's). There was no known employee over exposure, and therefore no medical attention was necessary.

To prevent such a spill from occurring again, a special type of drum hand truck has been ordered. This drum hand truck is designed to move plastic or poly drums. The drum truck has flat rounded forks rather than the angled forks. It also has a strap to secure the drum to the hand truck. All appropriate personne!

will be trained on the proper use of the poly drum hand truck.

% won,eeme m

e ,

,1f you have any questions concerning this notification, please conta

  • oam Simpson at (704) 875-5034 or John Williamson at (704) 875-5894.

.b David W. Phillips Environmental Manager McGuire Nuclear Site cc: NRC Regional Administrator Region il NRC Document Control Desk NRC Document, NRC-McGuire Resident inspector Rex Gleason, NCDEHNR Mooresville Office I

1 l

l 1