ML20101J193

From kanterella
Jump to navigation Jump to search
Annual Radioactive Effluent Release Rept
ML20101J193
Person / Time
Site: McGuire, Mcguire  
Issue date: 12/31/1995
From: Mcmeekin T
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9604010330
Download: ML20101J193 (55)


Text

-

-- ll-1 i

r DukeIbwer Company T. C M6VEExn McGuire Nudear Generation Depanment VicePresident :

12700Hagers fenRoad(MG01\\T)

(104)8754800 Hunlenville, NC28078&985

~ (704)8754809 Fax

}

-l l

)

otncesmousne March 25, 1996 4

U. S. Nuclear Regulatory Commission I

Document Control Desk-washington, D.C.

20555 i

i

Subject:

McGuire Nuclear Station

-i Docket Nos. 50-369 and 50-370 I

Annual Radioative Effluent Release Report Pursuant to Technical Specification 6.9.1.7 and SLC 16.11-16.2 of the McGuire Nuclear Station Selected Licensee Commitment Manual, attached is r

the subject report covering 1995.

The following attachments are the contents of this report: Radioactive Effluent Releases and Supplemental Information

. Attachment 2 Solid Waste Disposal Report Unplanned Offsite Releases Fuel Cycle Calculation Inoperable Monitoring Equipment Revision 10 to the. Corporate Process Control Manual was approved for use i

at McGuire on December 27, 1995.

This revision was submitted to the NRC on January 10, 1996.

Revision 37 to the Offsite Dose Calculation Manual (ODCM) was approved for use at McGuire on January 1, 1996. All dose calculation model-assumptions are contained in the ODCM.

This revision was submited to the NRC on January 2, 3996.

Questions or problems concerning this report should be directed to Kay

)

Crane at (704) 875-4306.

i i

Very truly yours, 7 CAM T. C. McMeekin, Vice President McGuire Nuclear Station Attachment 010053 9604010330 951231 J

i PDR ADOCK 05000369 R

PDR w on =rw o.-

I {

e l

March 25, 1996 l

NRC Document Control Desk Page 2 cc:

Mr. Victor Nerses Office of Nuclear Reactor Regulation Washington, D.C.

20555 Mr.

S.

D. Ebneter, Regional Administrator U.

S. Nuclear Regulatory Commission

)

Region II 101 Marietta St., NW Suite 2900 Atlanta, GA 30323 l

Mr.

D.

Brown, Chief Division of Radiation Protection P.O.

Box 27687

Raleigh, N.C.

27611-7687 i

American Nuclear Insurers Town Center, Suite 300S 29 South Main Street West Hartford. CT 06107-2445 Mr. G.

F. Maxwell Senior Resident Inspector McGuire Nuclear Station l

i l

Radioactive Effluent Releases and Supplemental Information i

e

! n=

t 1

f I

1 i

l UNIT 1 r

i i

I i

r l

l l

l l

l l

e t*

MCGUIRE NUCLEAR STAil0N UNIT 1 RADICACTIVE EFFLUENT RELEASES DATE : 02/15/ %

I.

LIQUID RELEASES YEAR : 1995 UNITS 1ST OTR 2ND OTR 3RD QTR 4TH OTR TOTAL 1.

GROSS RADIOACTIVITY A.

TOTAL RELEASE CURIES 1.92E 02 4.15E-03 6.69E-03 5.91E-03 3.59E-02 S.

AVERAGE CONCENTRATION RELEASED UCI/ML 2.41E 11 4.23E-12 6.74E-12 7.13E 12 9.98E 12 C.

MAXIMUM CONCENTRATION RELEASED UCI/ML 5.09E 10 1.11E 10 1.45E 10 1.95E-10 5.09E 10 2.

TRITIUM A.

TOTAL RELEASE CURIES 6.08E+01 5.77E+01 7.67E+01 1.28E+02 3.23E+02 B.

AVERAGE CONCENTRATION RELEASED UCI/ML 7.65E-08 5.88E-08 7.73E-08 1.54E-07 8.98E 08 3.

DISSOLVED NOBLE GASES A.

TOTAL RELEASE CURIES 4.18E-04 6.67E 04 1.72E-03 1.56E-03 4.36E-03 8.' AVERAGE CONCENTRATION RELEASED UC!/ML 5.26E 13 6.79E 13 1.73E 12 1.88E 12 1.21E-12 4.

GROSS ALPHA ACTIVITY A.

TOTAL RELEASE CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.

AVERAGE CONCENTRATION RELEASED UCI/ML 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.

VOLUME OF LIQUID WASTE TO DISCHARGE CANAL LITERS 6.38E+05 7.53E+05 1.27E+06 6.70E+06 9.37E+06 6.

VOLUME OF DILUTION WATER LITERS 7.94E+11 9.82E+11 9.92E+11 8.30E+11 3.60E+12 7.

RADIONUCLIDES RELEASED CURIES EC RATIO H-3 6.08E+01 5.77E+01 7.67E+01 1.28E+02 3.23E+02 8.98E-05 NA-24 2.7BE-06 0.00E+00 1.51E 06 0.00E+00 4.29E 06 2.38E 11 CR 51 1.49E-03 1.54E-04 9.86E-06 6.21E 04 2.28E-03 1.27E 09 MN 54 2.40E-03 1.07E-03 1.26E 04 1.55E-04 3.75E-03 3.47E-08 FE 59 8.08E-05 1.76E-05 3.43E-06 6.37E 05 1.66E 04 4.60E 09 CO 57 1.07E-05 4.57E 06 6.03E-06 2.96E-06 2.43E-05 1.12E-10 co-58 9.18E-03 1.76E-03 3.56E 03 3.16E 03 1.77E-02 2.46E 07 CO-60 2.32E-03 8.32E-04 1.55E-03 1.11E 03 5.81E-03 5.38E 07 BR-82 2.80E 06 3.83E 06 3.37E 06 4.75E-06 1.47E 05 1.02E 10 RB-88 0.00E+00 0.00E+00 5.64E 06 0.00E+00 5.64E-06 3.92E 12 SR-92 3.69E-06 0.00E+00 0.00E+00 1.89E-06 5.59E-06 3.88E-11 Y 92 5.94E-06 0.00E+00 6.89E 06 0.00E+00 1.28E-05 8.91E 11 NS 95 2.27E 04 6.08E-05 0.00E+00 2.65E-05 3.14E-04 2.91E 09 NS 97 1.87E 05 5.60E 06 0.00E+00 1.76E-05 4.19E 05 3.88E 11 ZR-95 1.34E-04 1.94E-05 0.00E+00 7.52E-06 1.61E-04 2.23E-09 MO-99 0.00E+00 0.00E+00 0.00E+00 2.40E-06 2.40E 06 3.33E-11 TC-99M 0.00E+00 4.30E-07 5.19E-07 2.40E-06 3.35E-06 9.30E-13 AG-110M 3.23E 05 9.02E 06 0.00E+00 7.11E 05 1.12E 04 5.21E 09 I 131 5.20E-06 2.35E-06 9.95E-06 6.55E-05 8.30E-05 2.31E-08 I-133 6.90E 07 5.51E-07 7.30E-06 9.04E 06 1.76E-05 6.98E-10 1 135 1.88E 04 0.00E+00 0.00E+00 0.00E+00 1.88E-04 1.74E-09 SB 122 0.00E+00 5.78E 07 0.00E+00 0.00E+00 5.78E-07 1.61E 11 58-124 2.14E 04 0.00E+00 2.33E 05 0.00E+00 2.38E-04 9.43E-09

$8 125 2.32E-03 9.75E 05 9.07E 04 4.04E-05 3.37E-03 3.12E-08

$N 113 2.39E 05 0.00E+00 0.00E+00 0.00E+00 2.39E 05 2.21E 10 CS 134 3.95E-05 4.87E 06 1.40E-04 6.18E-05 2.46E-04 7.61E-08 CS 137 4.41E 04 7.74E 05 3.29E-04 3.25E-04 1.17E 03 3.26E-07 CS 138 2.22E-06 0.00E+00 1.33E-06 0.00E+00 3.54E 06 2.46E 12 LA 140 6.57E-06 2.82E 06 0.00E+00 1.53E-04 1.62E 04 5.00E 09 CE 144 0.00E+00 2.32E 05 0.00E+00 1.04E-05 3.36E 05 3.11E-09 KR 85M 0.00E+00 1.53E 07 0.00E+00 0.00E+00 1.53E-07 4.26E-13 XE-133 3.99E 04 6.12E 04 1.68E-03 1.54E 03 4.24E-03 1.18E 08 XE 133M 0.00E+00 0.00E+00 1.29E 05 3.57E-06 1.65E-05 4.58E 11 XE 135 1.90E-05 5.44E 05 2.15E 05 1.22E-05 1.07E-04 2.98E-10 TOTAL EC RATIO 9.12E 05

_. ~ -.

MCGUIRE UNIT 1 LIQUID RELEASE 001-090 95 7.94E+11 02/15/ %

SKIN MAXIMUM DOSE-9.760-0* MREV.

CRITICAL AGE-TEEN CRITICAL PATla'AY-SHORE C5 60

75. f 1.'

SB 125 7.'il ).

CS 137 6.90 %

BCE MAXIMUM DOSE-3.64E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-FISH CS 134 5.89 %

l CS 137 92.61 %

LIVER MAXIHLM DOSE-6.37E-03 MREM CRITICAL AGE-CHILD CRITICAL PATWAY-

'.sRIlf,1.C f

H 3

73.21 %

l CS 137 22.87 %

1 T. BODY MAXIMUM DOSE-5.00E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 93.34 %

TdYRSID MAXItRM DOSE-4.69E-03 MREM CRITICAL /GE-CHILD CRITICAL PATHNAY-DRIEING l

H 3

99.52 %

l f

KIDNEY MAXIMLM DOSE-5.22E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIKING l

H 3

89.33 %

CS 137 9.11 %

LLNG MAXIMUM DOSE-4.87E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAV-DRIEING H

3 95.69 %

GI-LLI MAXIMUM DOSE-5.70E-03 MREM CRITICAL AGE-ADULT CRITICAL PATHMAY-DRIMING

)

i H

3 61.38 %

4 j

te 95 28.62 %

l I

t f1 4

34 I

a e

e, MCGUIRE UNIT 1 LIQUID RELEASE 091-181 95 9.82E+11 02/15/96 SKIN MAXIMUM DOSE-2.72E-05 MREM CRITICAL AGE-TEEN CRITICAL PATHNAY-SHORE MN 54 7.41 %

CO 60 84.55 %

BONE MAXIMUM DOSE-2.46E-04 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH CS 137 93.89 %

LIVER MAXIMUM DOSE-4.00E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRI KING H

3 93.22 %

CS 137 5.53 %

T. BODY MAXIMUM DOSE-3.78E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIMING H

3 98.43 %

THYROID MAXINUM DOSE-3.73E-03 MREM CRITICAL #GE-CHILD CRITICAL PATHMAY-DRIMING H

3 99.81 %

KIDNEY MAXIMUM DOSE-3.81E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHHAY-DRI EING H

3 97.67 %

LUNG MAXIMUM DOSE-3.76E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRI EING H

3 99.13 %

GI-LLI MAXIPRJM DOSE-3.87E-03 MREM CRITICAL AGE-CHILD CRITICAL PATEAY-DRIEING H

3 96.19 %

6 9

e e,

MCGUIRE UNIT 1 LIQUID RELEASE 182-273 95 9.92E+11 02/15/96 SKIN MAXIMUM DOSE-5.02E-05 MREM CRITICAL AGE-TEEN CRITICAL PATMAY-SHORE C5 60 81.16 %

CS 137 8.24 %

BONE MAXIttJM DOSE-1.23E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH CS 134 22.94 %

CS 137 76.23 %

LIVER MAXIHLM DOSE-6.25E-03 MREM CRITICAL AGE-CHILD CRITICAL PATMAY-DRIEING H

3 77.97 %

CS 134 7.40 %

CS 137 14.34 %

f.,-

3, T. BODY MAXIMUM DOSE-5.13E-03 MREM CRITICAL AGE-CHILD CRITICAL PAT MAY-DRIKING

[h H

3 94.91 %

b THYROID MAXIMLM DOSE-4.89E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIMING H

3 99.65 %

[.,

I KIDEY MAXIitJM DOSE-5.31E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIKING H

3 91.64 %

CS 137 5.50 %

LLNG MAXIMUM DOSE-5.04E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIKING l

H 3

96.70 %

}i, GI-LLI MAXIMUM DOSE-4.94E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRI EING H

3 98.68 %

4 1

4 I

t.

MCGUIRE UNIT 1 LIQUID RELEASE 274-365 95 8.30E+11 02/15/96 SKIN MAXIMUM DOSE-4.28E-05 MREM CRITICAL AGE-TEEN CRITICAL PATHHAY-SHORE CU 60 81.62 %

CS 137 11.47 %

BONE MAXIMUM DOSE-1.27E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH l

CS 134 11.74 %

CS 137 87.64 %

,r.

LIVER MAXIMM DOSE-1.11E-02 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRI EING i

H 3

88.02 %

[

CS 137 9.61 %

r; li T. BSDY MAXIMLM DOSE-9.97E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 97.62 %

-j jf THYRUID MAXIMLM DOSE-9.81E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING l

I H

3 99.25 %

b; KIDNEY MAXIMUM DOSE-1.02E-02 MREM CRITICAL AGE-CHILD CRITICAL PATHHAY-DRIEING

(

IO H

3 95.77 %

j J

LtMG MAXIMM DOSE-9.89E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING b

i H

3 98.39 %

X Nl GI-LLI MAXIMLM DOSE-9.84E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING

  1. ! I

?'

\\

H 3

98.90 %

tj l f i y

V r$

k l

l i

i

e.

NCGUIRE UNIT 1 LIQUID RELEASE 001-365 95 3.60E+12 02/15/ %

SKIN MAXIMUM DOSE-2.11E-04 MREM CRITICAL AGE-TEEN CRITICAL PATHHAY-SHORE 4

C5 60 79.25 %

CS 137 7.64 %

BONE MAXIMUM DOSE-4.24E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHHAY-FISH CS 134 12.80 %

CS 137 86.11 %

LIVER MAXIMJM DOSE-2.70E-02 MREM CRITICAL AGE-CHILD CRITICAL PATIMAY-DRIEING 1

H 3

83.22 %

CS 137 12.91 %

T. BODY MAXIMUM DOSE-2.34E-02 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIMING H

3 96.30 %

THYRSID MAXIMLM DOSE-2.26E-02 MREM CRITICAL AGE-CHILD CRITICAL PATIMAY-DRIMING H

3 99.48 %

KIDNEY MAXIMUM DOSE-2.40E-02 MREM CRITICAL AGE-CHILD CRITICAL PATIMAY-DRIMING H

3 93.85 %

LUNG MAXIMUM DOSE-2.30E-02 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIEING H

3 97.61 %

GI-LLI MAXIMLM DOSE-2.34E-02 MREM CRITICAL AGE-CHILD CRITICAL PATEAY-DRIEING l

H 3

96.22 %

l l

l l

l l

1

[

MCGUIRE NUCLEAR STATION UNIT 1 RADIOACTIVE EFFLUENT RELEASES DATE : 02/15/96 II. AIRBORNE RELEASES YEAR : 1995 UNITS 1ST OTR 2ND OTR 3RD QTR 4TH OTR TOTAL 1.

TOTAL NO8LE GASES CURIES 2.85E+01 1.78E+01 3.00E+01 4.97E+01 1.26E+02 2.

TOTAL HALOGENS CURIES 1.37E-04 1.26E-06 1.24E-05 2.58E-05 1.76E-04 3.

TOTAL PARTICULATE GROSS BETA GAMMA CUR!ES 1.58E-04 3.92E-05 9.58E-04 9.53E-06 1.16E-03 4.

TOTAL TRITIUM CURIES 4.65E+00 4.68E+00 5.60E+00 1.45E+01 2.94E+01 5.

TOTAL PARTICULATE GROSS ALPHA ACTIVITY CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.

MAXIMUM NOBLE GAS RELEASE RATE UCI/SEC 1.60E+03 1.60E+03 1.60E+03 1.60E+03 1.60E+03 7.

RA010NUCL! DES RELEASED CURIES EC RATIO H3 4.65E+00 4.68E+00 5.60E+00 1.45E+01 2.94E+01 7.09E-04 PARTICULATES CL-38 8.95E-08 0.00E+00 0.00E+00 0.00E+00 8.95E-08 3.60E 12 CO-58 8.73E-05 0.00E+00 0.00E+00 9.42E-06 9.68E-05 2.33E-07 BR-82 7.47E-08 6.42E-08 4.42E-08 5.10E-08 2.34E-07 1.13E-10 RB 88 3.63E-07 2.91E 07 1.16E-06 5.44E 08 1.86E-06 5.00E-11 1

C-11 6.98E-05 3.88E-05 9.57E-04 0.00E+00 1.07E-03 4.28E-09 HALOGENS I-131 1.67E 05 1.26E-06 4.94E-06 8.45E 06 3.13E-05 3.78E-07 I-132 0.00E+00 0.00E+00 0.00E+00 1.68E-05 1.68E 05 2.02E 09 I-133 1.20E-04 0.00E+00 7.42E-06 4.36E-07 1.28E 04 3.09E 07 I 134 0.00E+00 0.00E+00 0.00E+00 1.10E-07 1.10E 07 4.44E-12 GASES AR-41 8.60E-01 8.60E 01 9.47E 01 9.76E 01 3.64E+00 8.79E-04 KR 85 1.74E-01 0.00E+00 0.00E&00 1.49E 01 3.23E-01 1.11E-06 KR-85M 9.89E-02 7.54E 02 1.( 2E 01 1.23E-01 3.99E 01 9.63E-06 KR-87 2.30E-02 1.10E 02 2.3 Y-02 2.68E-02 8.38E-02 1.01E-05 KR-88 1.08E-01 9.24E-02 1.1\\E 01 1.07E-01 4.18E-01 1.12E 04 XE 131M 1.65E-02 0.00E+00 3.3F 02 3.01E-02 7.99E-02 9.64E-08 XE 133 2.18E+01 1.39E+01 2.19.:Di 4.11E+01 1.00E+02 4.84E 04 XE 133M 1.55E 01 1.73E 01 2.01E-01 6.39E-01 1.17E+00 4.69E 06 XE-135 5.20E+00 2.66E+00 5.0R +00 6.47E+00 1.94E+01 6.68E-04 TOTAL EC RATIO 2.88E-03 i

l 1

i

1 e

MCGUIRE UNIT I GAS DOSE 001-090 95 RELEASE HEIGHTED IET REPORT StRMARY 02/15/96 SPECIAL LOCATION AT 0.50 MILES tNE NOBLE GAS EXPOSURE:

BETA AIR DOSE = 3.28E-02 MILLIRADS GAPMA AIR DOSE = 2.43E-02 MILLIRADS TOTAL BODY DOSE = 1.56E-02 MILLIREM TerTAL SKIH DOSE = 3.56E-02 MILLIREM KR 88 6.84%

KR 88 4.13%

XE133 22.27%

XE153 27.49%

XE135 37.77%

XE135 43.76%

AR 41 31.88%

AR 41 22.44%

.- y MCGUIRE UNIT 1 CAS DOSE 001-090 95 RELEASE MIGHTED MET REPORT SLRMARY 02/15/ %

SPECIAL LOCATION AT 0.50 MILES ESE IODINE, PARTICULATE, AND TRITIUM EXPOSURE S M RY:

MAXIMLM ORGAN

- THYROID CRITICAL AGE

- CHILD CRITICAL PATHHAY - VEGET 3 77.12%

MAXIMUM ORGAN DOSE

  • 9.32E-03 HILLIREM H

3 95.43%

i l

i I

e

e l

MCGUIRE UNIT 1 GAS DOSE 091-181 95 RELEASE MEIGHTED MET REPORT St#9tARY OU15/%

SPECIAL LOCATION AT 0.50 MILES 1+1E NOBLE GAS EXPOSURE BETA AIR DOSE a 3.07E-02 MILLIRADS i

GAtttA AIR DOSE = 2.35E-02 MILLIRADS TOTAL BODY DOSE = 1.51E-02 MILLIREM TOTAL SKIN DOSE = 3.31E-02 MILLIREM KR 88 7.06%

KR 88 4.46%

XE133 23.93%

XE135 30.85%

i 1

XE135 27.36%

XE135 33.12%

AR 41 40.60%

AR 41 29.64%

I l

MCGUIRE LMIT 1 GAS DOSE 091-181 95 RELEASE MEIGHTED ET REPORT SLAttARY OU15/%

SPECIAL LOCATIER4

?'

AT 0.50 MILES ESE 10 DIE, PARTICULATE, AND TRITILM EXPOSURE SLAMARY:

MAXIMUM ORGAM

- THYROID CRITICAL AGE

- CHILD CRITICAL PATHNAY - VEGET 3 78.29%

MAXIHLM ORGAN DOSE = 7.04E-03 MILLIREM H

3 99.71%

P O

.I MCGUIRE LMIT 1 GAS DOSE 182-273 95 RELEASE HEIGHTED MET REPORT St#ttARY 02/15/96 SPECIAL LOCATI m t

AT 0.50 MILES tM NOBLE GAS EXPOSURE:

i i

BETA AIR DOSE = 3.39E-02 MILLIRADS GAtt1A AIR DOSE a 2.36E-02 MILLIRADS TOTAL BODY DOSE = 1.50E-02 MILLIREM TOTAL SKIN DOSE o 3.41E-02 MILLIREM KR 88 6.71%

KR 88 4.07%

XE133 27.87%

XE133 34.70%

XE135 30.2u%

XE135 35.14%

AR 41 33.92%

AR 41 24.01%

D !

(

MCGUIRE LMIT 1 CAS DOSE 182-273 95 RELEASE HEIGHTED PET REPORT St#ttARY 02/15/ %

5' SPECIAL LOCATI m AT 0.50 MILES E

)

1 IODINE, PARTICULATE, AND TRITIUM EXPOSURE St#9tARY:

4 l 3

MAXIPEM ORGAN

- THYRSID

)

CRITICAL AGE

- CHILD CRITICAL PATHNAY - VEGET 9 78.16%

'i i

MAXIMLA1 ORGAN DOSE = 8.77E-03 MILLIREM H

3 98.31%

l

m__...

l

[

t NCGUIRE UNIT 1 GAS DOSE 274-365 95 RELEASE HEIGHTED HET REPORT SLM1ARY 02/15/96 l

SPECIAL LOCATION l

AT 0.50 MILES WE NOBLE GAS EXPOSURE:

l BETA AIR DOSE = 5.41E-02 MILLIRADS GAPflA AIR DOSE = 3.90E-02 HILLIRADS u

TOTAL BODY DOSE = 2.50E-02 HILLIREM TOTAL SKIN DOSE a 5.83E-02 MILLIREM i

KR 88 5.57%

KR 88 3.29%

4' XE133 22.16%

XE133 26.93%

XE135 40.92%

XE135 46.57%

AR 41 29.94%

AR 41 20.67%

]

D!?,

?\\

&: I kly<

T i

l HCOUIRE LMIT 1 CAS DOSE 274-365 95 RELEASE HEIGHTED ET REPtNtT SLMtARY 02/15/96

~ el

?.]

l SPECIAL LOCATION AT 0.50 MILES ESE y,

+

i l

-t

s 1

IODINE, PARTICULAYE, AND TRITIUM EXPOSURE SthMARY:

k MAXIlut ORGAN

- THYROID l

CRITICAL AGE

- CHILD ff CRITICAL PATHNAY - VEGET 3 78.27%

6 HAXIlm ORGAN DOSE = 4.25E-02 HILLIREM Q6 H

3 98.95%

'b 9

T d

i i

l l

\\

i B

1 MCGUIRE UNIT 1 GAS DOSE 001-365 95 RELEASE MEIGHTED MET REPORT SIM1ARY 02/15/96 SPECIAL LOCATION AT 0.50 MILES INE NOBLE GAS EXPOSURE:

BETA AIR DOSE = 1.50E-01 HILLIRADS GAPMA AIR DOSE a 1.09E-01 MILLIRADS TtRAL BODY DOSE = 6.99E-02 NILLIREM TOTAL SKIN DOSE = 1.59E-01 MILLIREM KR 88 6.35%

KR 88 3.86%

XE133 23.67%

XE133 29.31%

XE135 35.47%

XE135 41.15%

AR 41 33.25%

AR 41 23.43%

j i

rl, 1

MCGUIRE UNIT 1 GAS DOSE 001-365 95 RELEASE MEIGHTED MET REPORT SLMtARY 02/15/ %

y SPECIAL LOCATION AT 0.50 MILES ESE IODINE, PARTICULATE, AND TRITILM EXPOSURE SLM1ARY:

MAXIttM URGAN

- THYRSID CRITICAL AGE

- CHILO CRITICAL PATHMAY - VEGET 3 78.12%

MAXIMUM ORGAN DOSE = 6.68E-02 MILLIREM i

H 3

98.45%

j l

s.__.;

e e

9 I

i 9

e l

l 1

l I

i UNIT 2

)

l l

l i

)

s MCGUIRE NUCLEAR STATION UNIT 2 RADIOACTIVE EFFLUENT RELEASES DATE : 02/15/96 YEAR : 1995 1.

LIQUID RELEASES UNITS IST OTR 2ND OTR 3RD QTR 4TH OTR TOTAL 1.

GROSS RADIDACTIVITY A.

TOTAL RELEASE CURIES 1.92E-02 4.15E 03 6.69E-03 5.91E 03 3.59E-02 B.

AVERAGE CONCENTRATION RELEASED UCI/ML 2.41E-11 4.23E 12 6.74E-12 7.13E-12 9.98E-12 C.

MAXIMUM CONCENTRATION RELEASED UCI/ML 5.09E-10 1.11E-10 1.45E 10 1.95E 10 5.09E-10 2.

TRITIUM A.

TOTAL RELEASE CURIES 6.08E+01 5.77E+01 7.67E+01 1.28E+02 3.23E+02 B.

AVERAGE CONCENTRATION RELEASED UC1/ML 7.65E-08 5.88E 08 7.73E 08 1.54E-07 8.98E-08 3.

DISSOLVED NOSLE GASES A.

TOTAL RELEASE CURIES 4.18E-04 6.67E 04 1.72E-03 1.56E 03 4.36E-03 B.

AVERAGE CONCENTRATION RELEASED UCl/ML 5.26E-13 6.79E 13 1.73E 12 1.88E-12 1.21E 12 4.

GROSS ALPHA ACTIVITY A.

TOTAL RELEASE CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.

AVERAGE CONCENTRATION RELEASED UCI/ML 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.

VOLUME OF L10U10 WASTE TO DISCHARGE CANAL LITERS 6.38E+05 7.53E+05 1.27E+06 6.70E+06 9.37E+06 6.

VOLUME OF DILUTION WATER LITERS 7.94E+11 9.82E+11 9.92E+11 8.30E+11 3.60E+12 7.

RADIONUCLIDES RELEASED CURIES EC RATIO H3 6.08E+01 5.77E+01 7.67E+01 1.2BE+02 3.23E+02 8.98E 05 NA-24 2.78E-06 0.00E+00 1.51E 06 0.00E+00 4.29E-06 2.38E-11 CR 51 1.49E-03 1.54E-04 9.86E-06 6.21E-04 2.28E-03 1.27E-09 MN 54 2.40E 03 1.07E-03 1.26E 04 1.55E-04 3.75E-03 3.47E-08 FE 59 8.08E 05 1.76E-05 3.43E 06 6.37E-05 1.66E-04 4.60E 09 00-57 1.07E-05 4.57E-06 6.03E 06 2.96E-06 2.43E-05 1.12E 10 CO 58 9.18E-03 1.76E-03 3.56E-03 3.16E-03 1.77E-02 2.46E-07 i

CD-60 2.32E-03 8.32E 04 1.55E-03 1.11E-03 5.81E 03 5.38E-07 BR-82 2.80E 06 3.83E-06 3.37E-06 4.75E-06 1.47E-05 1.02E-10 RB-88 0.00E+00 0.00E+00 5.64E-06 0.00E+00 5.64E-06 3.92E 12 SR-92 3.69E 06 0.00E+00 0.00E+00 1.89E-06 5.59E-06 3.88E 11 Y 92 5.94E-06 0.00E+00 6.89E-06 0.00E+00 1.28E 05 8.91E 11 NB-95 2.27E 04 6.08E-05 0.00E+00 2.65E-05 3.14E-04 2.91E-09 NS-97 1.87E-05 5.60E-06 0.00E+00 1.76E-05 4.19E 05 3.88E 11 ZR-95 1.34E-04 1.94E 05 0.00E+00 7.52E-06 1.61E-04 2.23E-09 MO-99 0.00E+00 0.00E+00 0.00E+00 2.40E-06 2.40E-06 3.33E 11 TC-99N 0.00E+00 4.30E-07 5.19E-07 2.40E-06 3.35E 06 9.30E-13 AG-110M 3.23E-05 9.02E-06 0.00E+00 7.11E-05 1.12E 04 5.21E-09 l-131 5.20E-06 2.35E-06 9.95E-06 6.55E-05 8.30E-05 2.31E-08 1 133 6.90E-07 5.51E-07 7.30E-06 9.04E-06 1.76E-05 6.98E-10 l-135 1.88E-04 0.00E+00 0.00E+00 0.00E+00 1.88E-04 1.74E-09

$8 122 0.00E+00 5.78E 07 0.00E+00 0.00E+00 5.78E-07 1.61E-11 58 124 2.14E-04 0.00E+00 2.33E-05 0.00E+00 2.38E-04 9.43E-09 58-125 2.32E-03

9. 75E-05 9.07E 04
4. 04E-05 3.37E-03 3.12E 08

$N-113 2.39E-05 0.00E+00 0.00E+00 0.00E+00 2.39E-05 2.21E-10 CS 134 3.95E-05 4.87E 06 1.40E-04 6.18E 05 2.46E 04 7.61E-08 CS-137 4.41E 04 7.74E-05 3.29E-04 3.25E-04 1.17E-03 3.26E-07 CS-138 2.22E-06 0.00E+00 1.33E 06 0.00E+00 3.54E-06 2.46E-12 LA-140 6.57E 06 2.82E-06 0.00E+00 1.53E 04 1.62E-04 5.00E-09 CE-144 0.00E+00 2.32E 05 0.00E+00 1.04E 05 3.36E-05 3.11E-09 KR-85M 0.00E+00 1.53E-07 0.00E+00 0.00E+00 1.53E-07 4.26E 13 XE 133 3.99E-04 6.12E 04 1.68E-03 1.54E-03 4.24E 03 1.18E-08 XE-133M 0.00E+00 0.00E+00 1.29E-05 3.57E-06 1.65E 05 4.5BE-11 XE-135 1.90E 05 5.44E-05 2.15E-05 1.22E 05 1.07E 04 2.98E 10 TOTAL EC RATIO 9.12E-05

~ _

.. =.

~

HCGUIRE UNIT 2 LIQUID RELEASE 001-090 95 7.94E+11 02/15/96 SKIN HAXIMUM DOSE-9.76E-05 MREH CRITICAL AGE-TEEN CRITICAL PATHMAY-SHORE CO 60 75.21 %

S8 125 7.91 %

CS 137 6.90 %

l BWE MAXIMUN DOSE-1.64E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH CS 134 5.89 %

CS 137 92.61 %

LIVER MAXIMUM DOSE-6.37E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 73.21 %

CS 137 22.87 %

T. BSDY MAXIttJM DOSE-5.00E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIEING H

3 93.34 %

THYROID MAXIMLM DOSE-4.69E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 99.52 %

KIDNEY MAXIHUN DOSE-5.22E-03 HREM CRITICAL AGE-CHILD CRITICAL PAT EAY-DRIEING H

3 89.33 %

l CS 137 9.11 %

l LUNG MAXIMUM DOSE-4.87E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 95.69 %

GI-LLI MAXIMLM DOSE-5.70E-03 HREM CRITICAL AGE-ADULT CRITICAL PATHNAY-DRIEING H

3 61.38 %

fB 95 20.62 %

r l

l i

1 4

l l

.- - - -..... _. _ ~. -

. -...~. - -. - - _ -.. --

l

i..

I MCGUIRE UNIT 2 LIElID RELEASE 091-181 95 9.82E+11 02/15/96 l

SKIN MAXIMJM DOSE-2.72E-05 HREM CRITICAL AGE-TEEN CRITICAL PATHNAY-SHORE l

\\

f MN 54 7.41 %

l CO 60 84.55 %

l BONE MAXIMUM DOSE-2.46E-04 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH CS 137 93.89 %

LIVER MAXIMLM DOSE-4.00E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIMING H

3 93.22 %

CS 137 5.53 %

T. BODY MAXIMUM DOSE-3.78E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING l

H 3

98.43 %

THYROID MAXIMM DOSE-3.73E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIEING H

3 99.81 %

KIDNEY MAXIMUM DOSE-3.81E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 97.67 %

LUNG' MAXIMUM DOSE-3.76E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIEING H

3 99.13 %

i GI-LLI MAXIMUM DOSE-3.87E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIMING H

3 96.19 %

i l

l l

~

f r

1 t

HCGUIRE UNIT 2 LIQUID RELEASE 182-273 95 9.92E+11 02/15/96 1

1 l

SKIN HAXIMUM DOSE-5.02E-05 HREM CRITICAL AGE-TEEN CRITICAL PATHNAY-SHORE l

CO 60 81.16 %

l CS 137 8.24 %

BONE HAXIHUM DOSE-1.23E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH CS 134 22.94 %

CS 137 76.23 %

LIVER HAXIHUM DOSE-6.25E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 77.97 %

CS 134 7.40 %

CS 137 14.34 %

T. BODY HAXIHUM DOSE-5.13E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHHAY-DRIEING H

3 94.91 %

THYROID HAXIHUH DOSE-4.89E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHHAY-DRIMING H

3 99.65 %

KIDNEY HAXIHUN DOSE-5.31E-03 HREM CRITICAL AGE-CHILD CRITICAL PAT)MAY-DRIEING H

3 91.64 %

CS 137 5.50 %

LLMG MAXIHUM DOSE-5.04E-05 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 96.70 %

GI-LLI HAXAHUM DOSE-4.94E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 98.68 %

l l

l l

9 MCGUIRE UNIT 2 LIQUID RELEASE 274-365 95 8.30E+11 02/15/96 SKIN MAXIMUM DOSE-4.28E-05 MREM CRITICAL AGE-TEEN CRITICAL PAT MAY-SHORE C6 60 81.68 %

CS 137 11.47 %

BONE MAXIMLM DOSE-1.27E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH CS 134 11.74 %

CS 137 87.64 %

LIVER MAXIMLN DOSE-1.11E-02 MREM CRITICAL AGE-CHILD CRITICAL PATIe4AY-DRIEING H

3 88.02 %

CS 137 9.61 %

T. BSDY MAXIMUM 90SE-9.97E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIEING H

3 97.62 %

THYROID MAXIMUM DOSE-9.81E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIEING H

3 99.25 %

i KIDEY MAXIltJM DOSE-1.02E-02 MREM CRITICAL AGE-CHILD CRITICAL FATHMAY-DRI MING H

3 95.77 %

l LUNG MAXIMUM DOSE-9.89E-03 MREM CRITICAL AGE-CHILD CRITICAL PATMAY-DRIMING H

3 98.39 %

GI-LLI HAXIMUM DOSE-9.84E-03 HREM CRITICAL AGE-CHILD CRITICAL PATHMAY-DRIMING H

3 98.90 %

i 1

i

.=.. _ _

MCGUIRE UNIT 2 LIQUID RELEASE 001-345 95 3.60E+12 02/15/96 SKIN MAXIMUM DOSE-2.11E-04 MREM CRITICAL AGE-TEEN CRITICAL PATHHAY-SHORE CO 60 79.25 %

CS 137 7.64 %

BONE MAXIMLM DOSE-4.24E-03 MREM CRITICAL AGE-CHILD CRITICAL PATHNAY-FISH CS 134 12.80 %

CS 137 86.11 %

LIVER MAXIMUM DOSE-2.70E-02 MREM CRITICAL AGE-CHILD CRITICAL PATHHAY-DRIEING H

3 83.22 %

CS 137 12.91 %

T. BODY MAXIMUM DOSE-2.34E-02 MREM CRITICAL AGE-CHILD CRITICAL PATEAY-DRIEING H

3 96.30 %

THYROID MAXIPM DOSE-2.26E-02 MREM CRITICAL AGE-CHILD CRITICAL PATEAY-DRIEING H

3 99.48 %

KIDNEY MAXIMUM DOSE-2.40E-02 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIKING H

3 93.85 %

LUNG MAXIttM DOSE-2.30E-02 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIMING H

3 97.61 %

GI-LLI HAXIMUM DOSE-2.34E-02 HREM CRITICAL AGE-CHILD CRITICAL PATHNAY-DRIEING H

3 96.22 %

P

~

MCGUIRE NUCLEAR STATION UNIT 2 RADIOACTIVE EFFLUENT RELEASES DATE : 02/15/ %

!!. AIRBORNE RELEASES YEAR : 1995 UNITS 1ST OTR 2ND OTR 3RD QTR 4TH OTR TOTAL i

1.

TOTAL NOBLE GASES CURIES 2.85E+01 1.78E+01 3.00E+01 4.97E+01 1.26E+02

2.. TOTAL HALOGENS CURIES 1.37E 04 1.26E 06 1.24E 05 2.58E-05 1.76E 04 3.

TOTAL PARTICULATE GROSS BETA-GAMMA CURIES 1.58E 04 3.92E 05 9.58E-04 9.53E-06 1.16E-03 4.

TOTAL TRITIUM CURIES 4.65E+00 4.68E+00 5.60E+00 1.45E+01 2.94E+01 5.

TOTAL PARTICULATE GROSS ALPHA ACTIVITY CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.

MAXIMUM NOBLE GAS RELEASE RATE UCl/SEC 1.60E+03 1.60E+03 1.60E+03 1.60E+03 1.60E+03 7.

RADIONUCLIDES RELEASE 0 CURIES EC RATIO H3 4.65E+00 4.68E+00 5.60E+00 1.45E+01 2.94E+01 7.09E-04 PARTICULATES CL 38 8.95E 08 0.00E+00 0.00E+00 0.00E+00 8.95E-08 3.60E-12 1

Co-58 '

8.73E 05 0.00E+00 0.00E+00 9.42E 06 9.68E-05 2.33E-07 BR 82 7.47E-08 6.42E 08 4.42E-08 5.10E-08 2.34E-07 1.13E-10 RB 88 3.63E-07 2.91E-07 1.16E-06 5.44E-08 1.86E-06 5.00E-11 C-11 6.98E-05 3.88E-05 9.57E-04 0.00E+00 1.07E-03 4.28E-09

?

HALOGENS l-131 1.67E-05 1.26E 06 4.94E-06 8.45E 06 3.13E-05 3.78E-07 l 132 0.00E+00 0.00E+00 0.00E+00 1.68E 05 1.68E 05 2.02E 09 I-133 1.20E-04 0.00E+00 7.42E-06 4.36E 07 1.28E-04 3.09E-07 I 134 0.00E+00 0.00E+00 0.00E+00 1.10E-07 1.10E-07 4.44E-12 GASES AR 41 8.60E-01 8.60E-01 9.47E-01 9.76E-01 3.64E+00 8.79E 04 KR 85 1.74E 01 0.00E+00 0.00E+00 1.49E-01 3.23E-01 1.11E-06 KR 85M 9.89E-02 7.54E 02. 1.02E 01 1.23E-01 3.99E-01 9.63E 06 KR 87 2.30E 02 1.10E 02 2.30E 02 2.68E-02 8.38E-02 1.01E 05 KR 88 1.08E-01 9.24E 02 1.11E-01 1.07E-01 4.18E-01 1.12E 04 XE-131M 1.65E-02 0.00E+00 3.33E-02 3.01E-02 7.99E-02 9.64E 08 XE-133 2.18E+01 1.39E+01 2.35E+01 4.11E+01 1.00E+02 4.84E-04 XE 133M 1.55E 01 1.73E-01 2.01E 01 6.39E-01 1.17E+00 4.69E-06 XE-135 5.20E+00 2.66E+00 5.06E+00 6.47E+00 1.94E+01 6.68E-04 TOTAL EC RATIO 2.88E-03 i

m

e McGLIIRE UNIT 2 GAS DOSE 001-090 95 RELEASE HEIGHTED MET REPORT SLAttARY 02/15/96 SPECIAL LOCATION AT 0.50 MILES NME NOBLE GAS EXPOSURE:

t BETA AIR DOSE = 3.28E-02 MILLIRADS GAP 9tA AIR DOSE = 2.43E-02 MILLIRADS TMAL BODY DOSE = 1.56E-02 HILLIREM TOTAL SKIN DOSE = 3.56E-02 MILLIREM KR 88 6.84%

KR 88 4.13%

XE133 22.27%

XE133 27.49%

.t XE135 37.77%

XE135 43.76%

f;.

AR 41 31.88%

AR 41 22.44%

.4

'*' k

.'i 5-h '

)

1 MCGUIRE UNIT 2 GAS DOSE 001-090 95 RELEASE HEIGHTED MET REPE T SLAftARY 02/15/96 i

SPECIAL LOCATION AT 0.50 MILES ESE IODINE, PARTICULATE, AND TRITILM EXPOSURE SLAf4ARY:

MAXIttM ORGAN

- THYROID i

CRITICAL AGE

- CHILD CRITICAL PATHHAY - VEGET 3 77.12%

4 MAXIMUM ORGAN DOSE = 9.32E-03 MILLIREM H

3 95.43%

-~

B l

.+

t l

I i

l i

MCGUIRE UNIT 2 GAS DOSE 091-181 95 RELEASE HEIGHTED MET REPORT SUPetARY 02/15/ %

SPECIAL LOCATION j

AT 0.50 MILES INE NOBLE GAS EXPOSURE:

BETA AIR DOSE a 3.07E-02 MILLIRADS i

GAP 91A AIR DOSE a 2.35E-02 MILLIRADS TOTAL BSDY DOSE = 1.51E-02 MILLIREM TUTAL SKIN DOSE a 3.31E-02 MILLIREM i

KR 88 7.06%

KR 88 4.46%

t XE133 23.93%

XE135 30.85%

i X2135 27.36%

XE135 33.12%

AR 41 40.60%

AR 41 29.64%

n' e

i E

7

'5 MCWIRE UNIT 2 GAS DOSE 091-181 95 RELEASE MEIGHTED MET REPORT SLDetARY 02/15/96 k

SPECIAL LOCATION AT 0.50 MILES ESE p

i ISDINE, PARTICULATE, AND TRITIUM EXPOSURE SUPMARY:

3l MAXIMAt ORGAN

- THYROID I !

CRITICAL AGE

- CHILD CRITICAL PATHNAY - VEGET 3 78.29%

! l

)

MAXIMUM ORGAN DOSE a 7.04E-03 MILLIREM H

3 99.71%

l 1

a MCGUIRE (MIT 2 GAS DOSE 182-273 95 RELEASE HEIGHTED MET REPORT SUPMARY O U15/96 SPECIAL LOCATION AT 0.50 MILES PM NOBLE GAS EXPOSURE:

3.39E-02 HILLIRADS BETA AIR DOSE =

GAPMA AIR DOSE = 2.36E-02 HILLIRADS TOTAL BODY DOSE = 1.50E-02 MILLIREM TOTAL SKIN DOSE = 3.41E-02 MILLIREM KR 88 6.71%

KR 88 4.07%

XE133 27.97%

XE135 34.70%

'l l

XE135 30.20%

XE135 35.14%

l AR 41 33.92%

AR 41 24.01%

'g if L l

?-

J l

MCGUIRE LMIT 2 GAS DOSE 182-273 95 RELEASE MEIGHTED MET REPORT SWMARY 02/15/ %

SPECIAL LOCATIS4 f

AT 0.50 MILES E

t 10 DINE, PARTICULATE, AND TRITIUM EXPOSURE SLM1ARY:

i MAXIMLM ORGAN

- THYROID CRITICAL AGE

- CHILD CRITICAL PATHNAY - VEGET 3 78.16%

HAXIMLM ORGAN DOSE

  • 8.77E-03 MILLIREM H

3 98.31%

l 1

MCGUIRE LHIT 2 CAS DOSE 274-365 95 RELEASE HEIGHTED M T REPORT SulttARY 02/15/96 SPECIAL LOCATIW4 l

AT 0.50 MILES 144E I

HOBLE GAS EXPOSURE:

BETA AIR DOSE = 5.41E-02 MILLIRADS GAttlA AIR DOSE = 3.90E-02 MILLIRADS l

TOTAL BODY DOSE = 2.50E-02 MILLIREM TUTAL SKIN 00SE = 5.83E-02 HILLIREM u

KR 88 5.57%

KR 88 3.29%

XE133 22.16%

XE133 26.93%

Q l

XE135 40.92%

XE135 46.57%

d l

AR 41 29.94%

AR 41 20.67%

p y

E f

e l

MCGUIRE UNIT 2 GAS DOSE 274-365 95 RELEASE MEIGHTED M T REPORT SLnttARY 02/15/ %

l

$PECIAL LOCATION l

AT 0.50 MILES ESE l

IODINE, PARTICULATE, AND TRITIUM EXPOSURE SLMtARY:

I MAXIMUM ORGAN

- THYRUID

(

CRITICAL AGE

- CHILD l

CRITICAL PATHHAY - VEGET a 78.27%

MAXIMUM ORGAN DOSE = 4.25E-02 MILLIREM H

3 98.95%

i l

l l

I l

l

?

l e

MCGUIRE UNIT 2 GAS DOSE 001-365 95 RELEASE HEIGHTED PET REPORT SL29tARY 02/15/96 SPECIAL LOCATION l

AT 0.50 MILES PNE l

1 HOBLE GAS EXPOSURE:

l BETA AIR DOSE = 1.50E-01 MILLIRADS GAPMA AIR DOSE = 1.09E-01 HILLIRADS i

TOTAL BODY DOSE = 6.99E-02 MILLIREM T MAL SKIN DOSE = 1.59E-01 MILLIREM KR 88 6.35%

KR 88 3.86%

XE133 23.67%

XE133 29.31%

XE135 35.47%

XE135 41.15%

AR 41 33.25%

AR 41 23.43%

~

l i

J l

h

.5 0

MCOUIRE UNIT 2 GAS DOSE 001-365 95 RELEASE MEIGHTED MET REPORT StAttARY 02/15/96 p'

l SPECIAL LOCATION F

AT 0.50 MILES ESE l.'

lt b

l ISDIPE, PARTICULATE, AND TRITIUM EXPOSURE SL29tARY:

^

I !

MAXIMUM ORGAN

- THYRUID CRITICAL AGE

- CHILD CRITICAL PATHNAY - VEGET 3 78.12%

i MAXIMUM ORGAN DOSE = 6.68E-02 MILLIREM 4

H 3

98.45%

i l

4 i

~

McGUIRE CONVENTIONAL WASTE WATER TREATMENT SYSTEM EFFLUENT AND DOSE

SUMMARY

- _ _. _ = _ -. -

1.

McGuire Conventional Waste Water Treatment System Effluent Summary ENVIRONMENTAL RADIOLOGICAL LABORATORY RADI0 ACTIVE EFFLUENT RELEASES YEAR 1995 02/21/%

PERIOD COVERED:

START DAY = 001 STOP DAY = 365 I.

LIQUID RELEASES UNITS PERIOD COVERED YEAR TO STOP 1.

GROSS RADI0 ACTIVITY A.

TOTAL RELEASE CURIES 0.00E+00 0.00E+00 2.

TRITIUM A.

TOTAL RELEASE CURIES 1.34E+00 1.34E+00 3.

DISSOLVED M8LE CASES A.

TOTAL RELEASE CURIES 0.00E+00 0.00E+00 4.

ALPHA ACTIVITY A.

TOTAL RELEASE CURIES 0.00E+00 0.00E+00 I

TOTAL VOLUME DISCHARGED (GALS.) =

7.33E+07 7.33E+07 MCGUIRE CONVENTIONAL WASTE WATER TREATMENT SYSTEM DOSE

SUMMARY

- 1995 RELEASES SKIN MAXIMUM DOSE-0.0 MREM CRITICAL AGE-NONE CRITICAL PATHWAY-NONE BONE MAXIMUM DOSE-0.0 MREM CRITICAL AGE-NONE CRITICAL PATHWAY-NONE LIVER MAXIMUM DOSE-4.85D-04 MREM CRITICAL AGE-CHILD CRITICAL PATHWAY-DRINKING H 3100%

T. BODY MAXIMUM DOSE-4.85D-04 MREM CRITICAL AGE-CHILD CRITICAL PATHWAY-DRINKING H 3100%

THYROID MAXIMUM DOSE-4.85D-04 MREM CRITICAL AGE-CHILD CRITICAL PATHWAY-DRINKING H 3100%

l KIDNEY MAXIMUM DOSE-4.85D-04 MREM CRITICAL AGE-CHILD CRITICAL PATHWAY-DRINKING '

H 3100%

1 LUNG MAXIMUM DOSE-4.85D-04 MREM CRITICAL AGE-CHILD CRITICAL PATHWAY-DRINKING H 3100%

l GI-LLI MAXIMUM DOSE-4.85D-04 MREM CRITICAL AGE-CHILD CRITICAL PATHWAY-DRINKING H 3 100%

0 I

I i

SUPPLEMENTAL INFORMATION l

l

~

P l

I MCGUIRE NUCLEAR STATION EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION REPORT DATE:

02/20/96 PERIOD COVERED: START DAY = 001 STOP DAY = 365

!. REGULATORY LIMITS A. NOBLE GASES AIR DOSE B. LIQUID EFFLUENTS DOSE

1. CALENDAR QUARTER GAMMA DOSE = 5 MRAD
1. CALENDAR QUARTER - TOTAL BODY DOSE = 1.5 MREM
2. CALENDAR QUARTER - BETA DOSE = 10 MRAD
2. CALENDAR QUARTER ORGAN DOSE

= 5 MREM

3. CALENDAR YEAR GAMMA DOSE = 10 MRAD
3. CALEhDAR YEAR TOTAL BODY DOSE = 3 MREM l
4. CALENDAR YEAR

- BETA DOSE = 20 MRAD

4. CALENDAR YEAR ORGAN DOSE

=

10 MREM C. IODINE - 131 AND 133, TRITIUM, PARTICULATES W/T 1/2 > 8 DAYS - ORGAN DOSE

1. CALENDAR QUARTER = 7.5 MREM i
2. CALENDAR YEAR

=

15 MREM

11. MAXIMUM PERMISSIBLE EFFLUENT CONCENTRATIONS A. GASEOUS EFFL'JENTS - INFORMATION FOUND IN OFFSITE DOSE CALCULATION MANUAL B. LIQUID EFFLUENTS - INFORMATION FOUND IN 10CFR20, APPENDIX 8, TABLE 2, COLUMN 2 Ill. AVERAGE ENERGY - NOT APPLICABLE i

IV. MEASUREMENTS AND APPROXIMATIONS OF TOTAL EADI0 ACTIVITY INFORMATION FOUND IN OFFSITE DOSE CALCultT10N MANUAL V. BATCH RELEASES A. LIQUID EFFLUENT l

1. 3.54E+02 = TOTAL NUMBER OF BATCH RELEASES I
2. 3.19E+05 = TOTAL TIME (MIN.) FOR BATCH RELEASES.

i

3. 4.37E+04 = MAXIMUM TIME (MIN.) FOR A BATCH RELEASE.

i

4. 9.00E+02 = AVERAGE TIME (MIN.) FOR A BATCH RELEASE.
5. 7.00E+00 = MINIMUM TIME (MIN.) FOR A BATCH RELEASE.
6. 1.83E+06 = AVERAGE DILUTION WATER FLOW DURING RELEASES (GPM).

B. GASEQUS EFFLUENT

1. 7.40E+01 = TOTAL NUMBER OF BATCH RELEASES.
2. 1.43E+06 = TOTAL TIME (MIN.) FOR BATCH RELEASES.
3. 4.48E+D4 = MAXIMUM TIME (MIN.) FOR A BATCH RELEASE.
4. 1.94E+04 = AVERAGE TIME (MIN.) FOR A BATCH RELEASE.

J. 2.40E+02 = MINIMUM TIME (MIN.) FOR A EATCH RELEASE.

VI. ABNORMAL RELEASES

.1. LIQUID l

1. NUMBER OF RELEASES 0
2. TOTAL ACTIVITY RELEASED (CURIES) 0 B. GASEOUS
1. NUMBER OF RELEASES 7
2. TOTAL ACTIVITY RELEASED (CURIES) ___, See Attachment 3 i

i l

SUPPLEMENTAL REPORT PAGE 2 McGUIRE NUCLEAR STATION Values represented by "0.00E+00" within the body of the Annual report are below the minimum detectable limits of the McGuire counting systems. Typical MDA's for the McGuire counting systems are listed below-AVERAGE ISOTOPE ENERGY (Kev)

MDA Liquid Xe-133 80 6.0E-08 Ce-144 133 1.2E-07 Kr-88 196 1.7E-07 i

Xe-135 249 2.3E-08 l

Kr-87 402 2.5E-07 Ca-137 661 2.6E-07 Mo-39 778 4.3E-07 Mn-54 834 2.2E-08 Zn-65 1115 4.0E-08 Co-60 1332 4.4E-08 Gas Xe-133 80 2.5E-08 Kr-85m 151 1.0E-08 Xe-131m 163 3.3E-07 Kr-88 196 4.7E-08 Xe-133m 233 7.9E-08 Xe-135 249 9.5E-09 Xe-138 258 6.3E-06 Kr-87 402 4.7E-08 Kr-85 514 2.5E-06 Xe-135m 526 1.9E-06 Ar-41 1293 3.6E-08

~

9

1..

l SUPPLEMENTAL REPORT PAGE 3 McGUIRE NUCLEAR STATION 1

l The estimated percentage of error for both Liquid and Gaseous effluent release data at McGuire Nuclear Station has been determined to be 16.1%. This value was derived by taking the square root of the sum of the squares of the following discrete individual estimates of error:

l l

l (1) Flow rate determining devices

=

  • 5%

(2) Counting error

=

  • 15%

1 (3) Sample preparation error

=

  • 3%

f l

Solid Waste Disposal Report t

I

l J

l i

February 26,1996 i

MEMORANDUM TO: Kay Crane

SUBJECT:

McGuire Nuclear Site Annual Solid Radwaste Disposal Report - 1995 Calendar Year l

Attached is the Annual Solid Radwaste Report for the period of January 1,1995 through December 31,1995 for the McGuire Nuclear Site. The format of the report includes information i

l as required by McGuire Station Selected Licensee Committment Manual Section 16.11. Please contact Joyce Correll at extension 4039 if further information is required.

Udl3 W. F. Byrum Radiation Protection Manager McGuire Nuclear Site cc: N. B. Sherrill G. T. Johnson J. C. Correll R. P. Michael (Chemistry)

L. E. Loucks (G.O.)

R. C. Lemons (G.O.)

i i

l i

I l

I i

i

AkCUlRE NUCLEAR STATION SOLID RADIOACTIVE WASTE SHIPPED TO A DISPOSAL FACILITY REPORT PERIOD 111/96 THROUGH.

12/31/95 Number of Number of Contamer Desposal Volume Waste Total TYPES OF WASTE SHIPPED Shipments Containers Type (cubic ft)

(cu. meter)

Class Cl WASTE FROM LGUID SYSTEMS 153 4.33 A

1.66E-03

)

1 STC NS (A) Dewatered 2% Powdex Rosin (brokered)

HIC B

C 207.4 5.87 1

A 125E-04 1

STC A/S (B) Dewatered 2% Powdex Rosin HIC B

C 373.1 10.56 A

2.23E-03 1

2 STC NS (C) Dewatered 2% Bead Rosin (brokered)

HC B

C 414.8 11.74 2

A 8.55E 04 1

2 STC NS t

(D) Dewstered 2% Bead Resin HIC B

C A

STC NS (E) Dewatered Radweste System Rosin HIC B

C A

STC NS (F) Dewatered Primary Bead Resin 1

1 Hic 120.3 3.40 1

B 5.83E+01 C

A STC 18.4 0.52 3

NS 4.33E+00 (G) Dewatered Mechanical Filter Meda 2

7 HIC B

25 0 71 4

C 1.68E +01 17.8 0.50 A

2.45E-01 (H) Dewatered Mechanical Filter Media 8

STC AS (Brokered)

HIC B

C A

STC NS (1) Sohdified Waste HIC B

C i

DRY SOLIO WASTE A

STC AS (A) Dry Active Waste (compacted)

HIC B

C A

STC 48 4 1.37 NS 221E+00 Dry Active Waste (non-compacted) 1 2

HlC B

C 345.1 9.77 A

3.75E+00 24 STC NS Dry Active Waste (brokered) 4 HIC B

C A

STC NS Dry Active Waste HIC B

(brokered/non-compactible)

C A

STC NS (B) Sealed Sources / Smoke Detectors HIC B

C A

STC NS (C) Sealed Sources HIC B

C A

STC NS (D) Irradiated Components HIC B

C 1511 20 42.76 3

A 4.00E+00 SUBTOTALS 10 45 66 80 1.89 3

NS 6.54E+00 120.30 3 40 1

B 5 83E+01 25 00 0 71 4

C 1.68E+01 TOTALS 1723 30 48 78 11 00 8 57E+01 2/23/96

1 MCGUIRE NOCLdAR SITE

SUMMARY

OF MAJOR RADIONUCLIDE COMPOSITION l Type of waste Nuclide

% Abundance II.Wsste from liquid systemsI.

, j

~

A. Dewatered Secondary Powdex Mn-54 6.7 Resin (Brokered)

Fe-55 37.4 Cs-134 4.9 Co-60 18.9 Ni-63 11.7 l

C-14 1.9 l

Tc-99 2.0 Cs-137 14.8 Ce-144 1.7 B. Dewatered Secondary Powdex Mn-54 4.9

)

l Resin Fe-55 35.4 i

Co-58 2.3 1

Co-60 17.9 i

Ni-63 11.1 C-14 1.8 Tc-99 2.3 Cs-134 4.8 Cs-137 17.4 l

Ce-144 2.0 l

C. Dewatered Secondary Bead Mn-54 3.7 Resin (Brokered)

Fe-55 22.1 Sb-125 1.2 Co-60 17.4 Ni-63 31.8 l

Cs-134 3.7 Cs-137 19.8 Ce-144 0.2 D. Dewatered Secondary Bead Mn-54 3.4 Resin Fe-55 11.8 l

Co-60 9.3 Co-58 1.9 l

Ni-63 17.0 Sb-125 0.9 l

Cs-134 7.6 Cs-137 46.2 Ce-144 1.9 l-131 0.1 E. Dewatered Radwaste System None shipped to a disposal facility l

Resin this report period.

k I

I

F. Dewatered Primary Bead Resin Mn-54 6.9 Fe-55 5.3 Co-58 65.9 Co-60 10.2 Ni-59 0.1 1

Ni-63 0.4 Sb-125 3.2 H-3 0.1 Cs-134 2.0 Cs-137 5.9 i

G. Dewatered Cartridge Filters Cr-51 0.4 Mn-54 4.1 i

Fe-55 55.8 Co-58 11.8 Co-60 19.8 Ni-63 6.4 C-14 0.1 Zr-95 0.3 Cs-137 0.4 Pu-241 0.2 i

Sb-125 0.7 H. Dewatered Cartridge Filters C-14 0.1 (Brokered)

Co-58 15.2 Co-60 18.7 Cr-51 0.2 Cs-137 0.3 Fe-55 53.8 H-3 0.1 Mn-54 4.2 Nb-95 0.1 Ni-63 6.0 Pu-241 0.1 Sb-125 0.5 Zr-95 0.7

1. Solidified Waste None shipped to a disposal facility i

this report period.

a

.. ~ _ -

-. -..,.. ~.

1 l

E orisolid wsasr- "~ ~.... '. ~ <", "", ~ ~ ~m.. "~" _..'..=...r..,.a er'~_ ~. _..^. ' ~+e s

A. Dry Active Waste Mn-54 1.3 Co-58 1.1 Co-60 31.5 Cs-137 0.7 Fe-55 49.3 Ni-63 15.5 H-3 0.4 l

C-14 0.2

. B. Sealed Sources / Smoke Detectors None shipped to a disposal facility this report period.

C. Sealed Sources None shipped to a disposal facility j

this report period, h

D. Irradiated Components None shipped to a disposal facility this report period.

2/27/96 l

n r

1 i

r 1

4 e

i 1

i i

i I

I 8

t cf Unplanned offsite Releases 1

i

4 September 12,1995 l

l l

MEMORANDUM TO FILE l

Subject:

McGuire Nuclear Station Release from Unit 2 Rx. Bldg.

to the Aux. Bldg. Due to UPAL Failure.

On August 16,1995, the unit 2 Upper Personnel Airlock auxiliary side door seal failed to inflate while the reactor side door was open. The result was a loss of l

containment integrity and an unplanned, uncontrolled release from containment to the auxiliary building. The release was monitored by the Unit Vent monitors (EMF 35,36,37, particulate, gas & iodine, respectively) before being released to the environment. 2 EMF 35,36,37 showed no change as a result of this release.

IEMF35 increased from ~30 CPM to ~60 CPM, and 1 EMF 36 increased from

~25 CPM to ~55 CPM. There was no change in 1 EMF 37. The activity did not exceed any Tech. Spec./SLC limits.

The activity released during this event was accounted for at the first of September when procedure HP/0/B/1003/01, Unit Vent Calculations, was performed.

SW M.B. Ramseur Shift Support Supentisor Radiation Protection McGuire Nuclear Station

.cc W.F.Byrum L.K.Criminger Annual Report l

l

4 1

1 l

l i

l I

Fuel Cycle Calculation l

l I

l i

]

l l

I

=

~

~

1995 NCGUIRE FUEL CYCLE SUtttARY DAYS 001-365 02/15/96 AT 16:26 i

i MAXINUM TOTAL BODY te4E 0.50 HILES 1.87E-01 AGE : CHILD l

FNS. GAS 1.40E-01 74.6 %

KR 88 6.3 %

XE133 23.6 %

XE135 35.4 %

AR 41 33.2 %

tetS. LIQUID 4.67E-02 24.9 %

CRITICAL PATH DRIEING 95.5 %

l H

3

%.3 %

CNS. GAS 6.67E-04 0.3 %

i XE133 51.1 %

XE135 10.9 %

AR 41 33.4 %

l MAXIt M ORGAN ESE 0.50 MILES 1.96E-01 AGE : CHILD ORGAN : LIVER l

tets. GAS 1.32E-01 67.0 %

CRITICAL PATH GARDEN 78.2 %

H 3

99.9 %

tetS. LIQUID 5.41E-02 27.5 %

CRITICAL PATH DRIEING 82.8 %

H 3

83.1 %

l CS 137 12.9 %

CNS. GAS 1.06E-02 5.3 %

CRITICAL PATH GARDEN 43.4 %

l H

3 92.3 %

i C6 60 7.4 %

l l

l l

l 1995 MCGUIRE FUEL CYCLE SUtf4ARY DAYS 001-365 02/15/96 AT 16:26 j

l l

l l

MAXIMUN TOTAL BODY FNE 0.50 MILES 1.87E-01 AGE : CHILD l

l MAXIMUM ORGAN ESE 0.50 MILES 1.96E-01 AGE : CHILD ORGAN : LIVER I

J W

l l

g u

. m.

a m

e f

e e

e l

METEOROLOGICAL DATA l

i l

l

i s

i 1

l i

l 1

l 8 8 8 8 8. 8 8 8 8 8 8 8 8 8.

um -8888888888888888 g

ai

  • "X 8 i -. =. 8 8 8 8 8 8 8 8 8 8 8 8 8 8.

8 l

A

"? 8.8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 g-i e

-e E9.. a.

8 8. 8 8 8 8 8 8 8 8 8.

. 8.

W1*8888888888888888 I

y em b id A.W.g t$. 2 8 8 8 8 8 8 8 8.

. 8.

. a. 8 8.

8

.a.

W

??8888888888888888 I

Br

  • 9 HB-l 7EEE888888EEEE888E I

718888888888888888 g

te. use tg*

E *..$. 8. :. 2 2 8 8. :. :.. 8.

. 8.. 8.. 8 g?'8888888888888888 I

7 m

o N

fi k$E8.EEE$$8$EE5$$E E

  • TT8888888888888888 8"

l

  • 9

.g l

E8 954E'E899$$$$E8$849 E

"E

?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 g

g

.N l

m 3S'888%28 8: :

a88 8

R fi5555555555555555 g

9e m

8 E

"E888888888E88E88E E

l

??8888888888888888 8

gm siSe

8;E8E;99EeEiEE8E "8. g 8 8 g 8 8 8 8 8 8 8 8 8 8 8 8 g2 2B a

u-8. me.imi. me.ime. me.ime. me.ime m

{"f0444gdW4Wpi4WJNespA4gd54ggigln4]5g 8

dE u : "i < *v

= me as. 2

~e ne :

....... ~..... ~ _ -.

__m.

,,.m

~,.

i o

2 1

1 lE88888'88888888888 8

um 8888888888888888 g

  • O!

an

-8.

"$. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

8 A 8 ?? 8 8 8 8'8 8 8 8 8 8 8 8 8 8 8 8

?

1*

=

fE28.888888,888888,8888 8

I W ?? 8 8 8 8 8 8 8 8 8 8 8 8 8'8 8 8 I

i 8

9*

i

8 gr
  • 4.W*$.8888888888888888 8

1 W

"?8888888888888888 g

b r

8-E$ "$.8888888888888888 8

- ru

,??.8888888888888888 E=o I$***

2

)

E

93. 8 8.~8 8.'8 8 8 8 8 8 8 8 8 8 8 8 8

u ng??8888888888888888 g

j u

-m gs s

JE8888888888888888 8

l118888888888888888 g

t.

I

.$. 8 8 8 8 8.'8 8 8 8 8 8 8 8 8 8 8 8

E i

I

??8888888888888.888 "9

g i

R i

E mu I

l l

E

  • I8888888888888888 8

E R

?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 g

1 a

g m-E ui 8888888888888888 8

l l* fY5555555555555555 g

l i

M 18 llgv888888888888888888 l

2 uB' 8 8 *8 8 8. g 8 8 *

  • g g 8 8 8 8 8
    • 8

.88 a

g-8 2

8 5...............h)kbh.gh....'OT '$.2'2.C'2.~4g dEff 5 g 8

a

.$dgdW4Wp14WJN4gdA4 Iu

      • T

'mt 3 -

NA u.

~.

l

[g8888888888888aa8 5

~.iiiiiiiiiiiiiiii g

ai

  • "X t
  • 2. "$. 5 8 8 8 8 8 8 8 8 8 8 8 8. a. a. 8 5

A a "? 8 8 8 8 8 8 8 8 8'8 8 8 8 8 8 8 g

?

1*

2 l

E E *$. 8 5 8 8 8 8 8 8 8 8 5 8 8 8 8. a.

E.

  • E ?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 I

9*

A 8 **.

-hha3k.8EE888888 EEEEEEE E

b

?.?. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 I

W i

g B

ho' 7EEEE*88E.88EEEEEEE E

?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 I

t*

=

EE:*

+ "93 3 2.. a. 8 8 8 8.. 8 8 8 8 8.. a.

8

."??8.888888888888888 ge 8

s kEEEEE8EEEEEEEEIE E

I'?T8'888888888888888

~

gg 8

1 nm

'E

  • EEEE88EEEEEE$E8EE E

?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

-lE E

.N l

h

  • EEI.EEEEEEEEE8EE8E 8

R

?"8888888888888888 y

9*

.a ma l

E NEEEIEE8888EEEIEE*

E l

??888888~8888888888 g

l Wo i

gl{d g :. g g 8 8 8. g g.: 8 g g 8 8. g 8 g os g-I e

.9 8

  • . *I' *iY' *i!' *RYME' *Y' *35' *? h' *h' * *RY WI. 2h',t i B

'r i

. -.- -.-..d i u

R 8

ES SY%.

I

.~~

m

)

I

I O-IE8888888888888888 8888888888888888 g~

um Ad

  • "X 9

t.

"$. 2 2. 8 8 8 8 8 8 0 8 8 8 8 8 5. :.

2 A 2 "i 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

?

1*

M w

gg*$$288888888888588 A

Wfi5555555555555555

  • 5

<n g!8d*.1"9**IE 849a = =

  • 1=

kW k 4

-.O N - N N

-m b

?.?8888888888888888 g

W m

g 8-E$

m.

~. ~ ~

- m

.,~-m s

to d*1*91g====1===11g 1

?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

!"a E @*.9 i

un: s * = 8 se==8=maae:

a l$$$$$5$$$$$$$$$$$$$

A u s~m 8

W *dd

> f*

-.. m # m m

d*.

  • 1 1 g 1
  • a

.. g - 1 *. 1 a 11*

~

- ~., ~ ~

m 2

1 M

ln**18528888888888888 1

g m

f f 4

    • *
  • 8. 1 1 1. E.
a. E.. - M1.11111 9

e b e.

N a

a sm.

=g

.-.o o.

g o o y,

R*

dd 44 5

mn

- o.

g

..... o.....

.. o i

dA i

u wIE8$$$$$$$EOUNA$$

WAa&&&4&&d&&&&&&di a

4. o o o o o o o o o. o o o o o g

W*

A*

Ed a22G88*E8232422%82

.hga l

t$ 5.55555555555.5.55555

.. o o

a-bo me.t to 28 1280 28 tW9 2006m8 J

lSud4"4EW*E4Wp44WWWgg2'2[.n'AYu'gjdE4[5g dA4 d545di

  • a
  • t
    • Y

'OTO'-.

u.0'M.

o

O o

S l

8888888888888888 8

w. 8888888888888888 Ai
  • "X 1

2 8,

"$. 8 8 8 8 8 8 8 8 8 8 8 8 8. a. 8 8 A = "i 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

?

1*

=

w E *. 8.. 8 8 8 8 8.. 8 8 8 8 8.. 8 8 8

W 19 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 I

8 I 3" A

EEE258E888888EEE88E8E E

W

??8888888888888888 I

Br 8

E 7E8$E888E8E$E888E8 E

118888888888888888 I

=

E 5:.*

a

  • "90 8. :.. 8 8 8 8. 8.. 0 8 8 8 8 8 8 E*au.

g7.T8888888888888888 I

o N

f4 2I.9E$$$88k5$EEE$$$

118888888888888888

~

W t*

8 NM EB 95$EE4$$E$E#E'$$$8E "E

?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 j

IE X

.u

$8 8

N h

8 N

5 Ti555555555d555555 5

9*

ag m-E "E$EE*$E$$E@8.EE$$$

l

??888888888888888:

98 N

$$98$$@EE#.E88.$88*8 Ei g5 ts 8: ::::

88:

88:

..g8:

...o o.

g-8,............,.o l=tdiggeW4Wp14WJN4 spa 4h.......la....e zl.pi4 digg 5 g d54 N-

< *v

v=

m.

o s.

l$8888888888888888 8

um 88888.88888888888 44

  • "X 8,

$.88.88888888888888 8

A 8 "i 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

?

1*

s E 9$. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

W 19'8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 I

8 8

.A 2"

g a.t.< 93. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

~

W

??8888888888888888 I

Ir 8

ru

  • $. 8 8 8. 8 8 8 8 8 8 8. 8 8 8 8 8 8 8

a E=.

118888888888888888 I

E g*.9 3*

E ".9$. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

ug??8888888888888888

-m u

W f4 2k 5 8 8 8 8 8 8 y y.y y 8, 8 8 y 8 y

m TT8888888888888888 I

  • 9 hm EW IR48ss8884?894;89 9

l??8888888888888888 8

I 99 n

mu 9.

R

??8888888888888888 8

9*

=

a<

m-E "E8E84EEI9@E@I.6445 l

??8888888888888888 8

9$

W.

$$$$$$$$$8.k$455k55 glEiEg 888888888888888888 95 =,*I'a'*'=,.dTOE.RY:2,8?m88?83'a'*l'a,d!0,RY

  • 1=amia,*
  • '9'*l' 5IId,<i E" 8Y:

B Wm usu u ~

uom m u n

i c

~

}

i f

l E888.~88888888.'88.8.88 8

888888888888'8888 i

u.

g I
  • .. TX 8 *.

$. 8 8 8 8. 8 8 8 8 8 8 8 8 8 8 8 8 8

A a "i 8 8 8 8 8 8 8 8 8 8:8 8 8 8 8 8 I

?

~*

l

  • $.-~8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

l W198888888888888888 y

t 44 i

IE.! t$. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

ow 4

l E

77IIEIIIIEIE888III I

B l

r l

8 M

8 tu "$.8888888888888888 118888888888888888 E" 6*.

a

  • ""$. 8 8 8 8 8 8 8 8 8 8 8 8. 8 8 8 8 8

"g?? 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 o*E,d4

. f*$. 8 8 8 8 8 8 8 8.. a. 8 8 8 8 8 8 s

T 8 8 8 8 8 8-8 8 8 8 8 8.8 8 8 8

,IT

.um I

iW

.$. 8 2 8 8 8 8 8 8 2 8 3 8. 3 8 8 8 8

"E

??8888888888888888 g

- y

.u

  • I.EEEEEEEEEEEE*8E8 E

?"8888888888888888

~

8 sg m-E "EEEEEEEEEEEEEI@EE E

l.

T1888888.

L a88888 T9 ga

~-

o W

gi E E E E E E E E E E E E E E E R. E E I * * * $ 8.. ~8 8. a 8 8 8 8.

  • 8 5 i

Es bB

~

8 888 gr l

'Eh R $ * * '

  • Y'
  • E' *R T M E'
  • Y'
  • a
  • 6' * !'
  • R Y i
  • *'*'*' ! B

~ - u d d.u. Idid f" SY: sd.

d d88?

Mm

~u u.m m u n

o 4

I Inoperable Monitoring Equipment l

l l

l I

R 0

e l

September 12,1995 I

MEMORANDUM TO FILE r

1

Subject:

McGuire Nuclear Station 1 EMF 38 out of service for a period exceeding theTech Spec limit of 30 days.

Reference:

Licensee Event Report (LER) 369/95-04 On August 21,1995, it was determined that 1 EMF 38, Containment Atmosphere Particulate Radioactivity Monitoring System, was technically past inoperable from October 11,1994, to August 15,1995. During a channel calibration, it was revealed that the filter paper had run out. A time delay relay for the filter paper not moving circuit was found to have failed. Routine samples taken during this time showed no unusual particulate activity.1 EMF 40, which contains a charcoal filter and is downstream of EMF 38, showed no increase in activity during the

)

inoperable perioo.

Since containment activity has a final release point out the Unit Vent, any activity released during this time period was accounted for by the monthly performance of procedure HP/0/B/1003/01, Unit Vent Calculations.

W W4t/L M.B. Ramseur Shift Support Supervisor Radiation Protection McGuire Nuclear Station

.cc W.F. Byrum L.K. Criminger Annual Report i

l

?