ML19317G281

From kanterella
Jump to navigation Jump to search
LER 78-008/04T-0:on 780305,waste Gas Header Overpressurized & Blew Auxiliary Bldg Loop Seals During RCS Degassing. Caused by Personnel Error.Personnel & Supervisors Instructed
ML19317G281
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 03/13/1978
From: Cooper J
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19317G278 List:
References
LER-78-008-04T, LER-78-8-4T, NUDOCS 8002280902
Download: ML19317G281 (2)


Text

.. - .-_.___-- _ _ _

Oi '

u. s. =ves.s An ascutArony commissiers
  1. sac acau aos LICENSEE EVENT REPORT EXHl8IT A

! cominos stocc: I, i 1 I I I l@ ,

cettAsa per on Tves ALL stouinao imponatArnous ._.. . _

r.o'Til IF l oc.u..c LI Q Rt2.Pi 3..lg[0101- a t O !mOr s. 0~ l... 0: 0 ; -go i 0lgg a a Lt .1,1oc ,a

l l 1 n.. a
gg. i . ; g - --

i, w con'T ~

_ _ _ Wa. i .

g; Qgt u 050-0 r 3:0 t 2 gi 0:3 i 0 : 5: 7 I agl0n r3 li! r317:a m . . , s_ . . . . . .. . . s , s. r. 1. ...o o.r.

er --

svaar osscairrios Ano anosasts cousscusscas

,. _ _ ___ .,_ g in Mode 5 operation, while degas g the Reactor Coolant System, the wasta ,

_. _ g ,g gas header was over-pressurized blowing the Auxiliary. Building loop seals.,

The instantaneous release race was 5% of the :nost restrictive noble gas

_ , g,j ,

_ g , limit. Redundancy NA. No safety hazard to the plant or public. This is

. ._ . . _. _ . r5TO I the 7th occurrence of this event. ,

. . . Io iil f f __.

@f .,

f O. C00. S'.  : 8 Cov8.s4%* 038 ,I 28 8e . [

. _ _ _ iot.

l Pi a @' ]@ Q @ [Z l 3 Z i ZI Z l Zi@ g,, @ [,Zj g_

c::...  : . . . , ..m, u

. ..r.... ..c.2

.. . s,m,  :: s ~.. ,o 6 ,a;'.;;; .. 1718I

.,. =

Wu 1 10 i 81

. u W

v 101 41 W

u 8, . l ol W.'n Ws' a%'Rr *%2W - ., nn ' , % p ' .;;.',2 , 'i.','h i;'  :::2;?::,,

L...D6 W@ .

laZ.J O >I o i 0: a' 0 gj@

Wg w@ u[ ZI 919'i 9fg

., ., ~

cAuse oescaieries amo conatern r Aertas @ ~

_,, ._ _ g (_'The cause of this event was personnel error. Temporary changes to OP-205 , _

, were not followed. Supervision and concerned personnel have been mada _

_ , , , , , , , aware of the consequences 'of not following approved procedures both ,

I i.,3II temporary and permanent. Discrepancy Report #C-00834 has been initiated. t_ .

t'!4 1.3 [

'#.'W  : .. e,.. . . . , @ s',7di!'

. .,::...,.,,....,, g L,.11J Lgj@ l d o f ol@l NA l [A,,J@! Operator observation l

  • fr.,,,, ds...

" u ~ a

  • u

..:.m :...-.,u n c

.u ....

(~ .! . i LGj (h,(..u.

128 curies nobl@e [ ds Aux 111ar.,.3s..u.,,@

7 Building NJ l

.. c.m'd

,s .. .

3".. .gl I , ! 1 1010 10 'CLZ.J@l NA l ~

' * ' " a

. .,:sa'.v.1.,,,, :......se s.....

._ l' l 1, I,O!0 i Ol@l NA l -

..2 * "' @

W' :' :'lL';';.'ls NA Ii6'.I

. d. @l .. "

l sac tst c . .

e G.. I;31' G,'.. .. os @ NA # : ieet ,et tt [

Avs er 7.tramtr' l- Gener / .n 904 ) 795-6486 ya (SEE ATTACIIED SUPPLE.'!F.NTAP.T INFOC!ATION SEIEET) 8002 280 7CQ ;i

[ SUPPLEMENTARY INPORMATION

\

. Report No.: 50-302/78-008/04T-0 2.

Facility: Crystal River Unit #3

3. Report Date: 13 March 1978
4. Occurrence Date: 5 March 1978
5. Identification of Occurrence:

Unplanned radioactive gas release to the atmosphere reported in accordance with 10 CFR 20.403.

6. Conditions Prior to Occurrence:

Mode 5 cold shutdown operation.

7. Description of Occurrence:

At 1410, an unplanned gas release occurred during plant cooldown. While desassing -

Reactor Coolant System, in preparation for RCS draindown, the Wasta Gas Surge tank  ;

was isolated by a temporary change to the Hydrogen Addition and Degasification "

Procedure (OP-205) . The purpose of the change was to put all the high activity gasses into one waste gas decay tank. After completion of degasification, the waste gas header was over-pressurized blowing the Auxiliary Building loop seals.-

A total of 128 curies of noble gasses, primarily Ze-133, was released. The instantan-g acus release rate was 5% .of the most restrictive noble gas limit set forth in Environ-mental Technical Specification.2.4.2.A(1). . .

8. Designation of Apparent Cause: -

The cause of this event was personnel error, in that the' camporary procedure change to OP-205 was not followed and the gas header was over-pressurized, blowing the Aux 111nry Building loop seals. l l

9. Analysis of Occurrence:

The health and safaty of the public was not affected in that the instantaneous release rate was 5% of the most restrictive noble gas limit.

10. Corrective Action:

Supervision & concerned personnel have been made aware of the consequences of not following approved procedures both temporary and per:anent. Discrepancy Reper

  1. C o0834 has been initiated.
11. Failure Data:

This is the 7th occurrence of this event due to blown loop seals.

1 1

i 1