Integrated Inspection Report 05000382/2019003
ML19310G722
Person / Time
Site: Waterford 
Issue date: 11/05/2019
From: John Dixon
NRC/RGN-IV/DRP
To: Vazquez S
Entergy Operations
References
IR 2019003
Preceding documents:
Download: ML19310G722 (37)


Text

November 5, 2019

SUBJECT:

WATERFORD STEAM ELECTRIC STATION, UNIT 3 - INTEGRATED INSPECTION REPORT 05000382/2019003

Dear Mr. Vazquez:

On September 30, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Waterford Steam Electric Station, Unit 3. On October 10, 2019, the NRC inspectors discussed the results of this inspection with you and other members of your staff.

The results of this inspection are documented in the enclosed report.

Two findings of very low safety significance (Green) are documented in this report. One of these findings involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.

A licensee-identified violation which was determined to be of very low safety significance is documented in this report. We are treating this violation as an NCV consistent with Section 2.3.2 of the Enforcement Policy.

If you contest the violation or significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; the Director, Office of Enforcement; and the NRC Resident Inspector at Waterford.

If you disagree with a cross-cutting aspect assignment or a finding not associated with a regulatory requirement in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; and the NRC Resident Inspector at Waterford Steam Electric Station. This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely,

/RA/

John L. Dixon, Jr., Chief Reactor Projects Branch D Division of Reactor Projects

Docket No. 05000382 License No. NPF-38

Enclosure:

As stated

Inspection Report

Docket Number:

05000382

License Number:

NPF-38

Report Number:

05000382/2019003

Enterprise Identifier: I-2019-003-0002

Licensee:

Entergy Operations, Inc.

Facility:

Waterford Steam Electric Station, Unit 3

Location:

Killona, LA 70057

Inspection Dates:

July 1, 2019 to September 30, 2019

Inspectors:

B. Baca, Health Physicist

L. Carson, Senior Health Physicist

K. Clayton, Senior Operations Engineer

M. Doyle, Operations Engineer

N. Greene, Senior Health Physicist

S. Makor, Reactor Inspector

J. O'Donnell, Health Physicist

F. Ramirez Munoz, Senior Resident Inspector

C. Speer, Resident Inspector

J. Vera, Resident Inspector

Approved By:

John L. Dixon, Jr., Chief

Reactor Projects Branch D

Division of Reactor Projects

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an integrated inspection at Waterford Steam Electric Station, Unit 3, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information. A licensee-identified non-cited violation is documented in report section: 7115

List of Findings and Violations

Failure to Periodically Calibrate Radiation Monitoring Equipment Cornerstone Significance Cross-Cutting Aspect Report Section Occupational Radiation Safety Green NCV 05000382/2019003-01 Open/Closed

[H.3] - Change Management 71124.05 The inspectors identified a Green non-cited violation (NCV) of 10 CFR 20.1501(c) for failure to periodically calibrate area radiation monitoring equipment used to perform dose rate measurements. Specifically, on or around January 18, 2012, the licensee began changing the periodic calibrations of area radiation monitors without verifying the instruments were in calibration.

Failure to Implement Procedures for Main Generator Exciter Maintenance Cornerstone Significance Cross-Cutting Aspect Report Section Initiating Events Green FIN 05000382/2019003-03 Open

[H.5] - Work Management 71153 The inspectors reviewed a self-revealed Green finding because the licensee did not follow procedure requirements when performing periodic maintenance on the main generator exciter. Specifically, the licensee did not implement the preventative maintenance steps required by Procedure ME-004-003, Main Exciter, Revisions 300 through 303, to perform inspection, cleaning, and testing of the main exciter during refueling outages.

Additional Tracking Items

Type Issue Number Title Report Section Status URI 05000382/2019003-02 Quantity of Radioactive Material Shipment Error 71124.08 Open LER 05000382/2019-004-00 Boron Dilution Alarm (Startup Channel High Neutron Flux) Inoperable Resulting in Operation or Condition Prohibited by Technical Specifications.

71153 Closed LER 05000382/2019-005-00 Automatic Reactor SCRAM due to Steam Generator 1 High Level Resulting from a 71153 Discussed

Main Turbine Trip and Subsequent Reactor Power Cutback due to Failed Diode Modules within the Main Exciter

PLANT STATUS

The Waterford Steam Electric Station, Unit 3, began the inspection period at 100 percent power.

On July 31, 2019, operators shutdown the reactor in accordance with Technical Specification 3.0.3 due to excessive leakage in the chemical and volume control system, due to a crack in a drain line weld. On August 7, 2019, operators restarted the reactor. The unit achieved full power on August 8, 2019, and maintained full power for the remainder of the inspection period.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors performed plant status activities described in IMC 2515 Appendix D, Plant Status and conducted routine reviews using IP 71152, Problem Identification and Resolution. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.01 - Adverse Weather Protection

External Flooding Sample (IP Section 03.04) (1 Sample)

(1) The inspectors evaluated readiness to cope with external flooding for the following areas on July 11, 2019:
  • Reactor auxiliary building
  • Turbine building

71111.04Q - Equipment Alignment

Partial Walkdown Sample (IP Section 03.01) (4 Samples)

The inspectors evaluated system configurations during partial walkdowns of the following systems/trains:

(1) Auxiliary feedwater during a period of increased risk significance due to plant shutdown lineup on August 2, 2019
(2) Emergency feedwater train B with train A inoperable for maintenance on August 3, 2019
(3) Auxiliary component cooling water train A with train B inoperable for maintenance on August 22, 2019
(4) Emergency diesel generator train A with train B inoperable for maintenance on September 16, 2019

71111.05A - Fire Protection (Annual)

Annual Inspection (IP Section 03.02) (1 Sample)

(1) The inspectors evaluated fire brigade performance during an unannounced drill on September 4, 2019

71111.05Q - Fire Protection

Quarterly Inspection (IP Section 03.01) (5 Samples)

The inspectors evaluated fire protection program implementation in the following selected areas:

(1) Fire area RAB 8C, switchgear room AB, on July 30, 2019
(2) Fire area ROOF W, main steam isolation valve A room, on July 30, 2019
(3) Fire area RAB 8B, switchgear room B, on August 23, 2019
(4) Fire area RAB 13, battery room 3A, on September 3, 2019
(5) Fire area RAB 1A, B, C, D, control room, on September 30, 2019

71111.06 - Flood Protection Measures

Inspection Activities - Internal Flooding (IP Section 02.02a.) (1 Sample)

The inspectors evaluated internal flooding mitigation protections in the:

(1) Flood zone 14, +46 heating, ventilation and air conditioning (HVAC) and chiller room, on July 25, 2019

71111.07A - Heat Sink Performance

Annual Review (IP Section 02.01) (1 Sample)

The inspectors evaluated readiness and performance of:

(1) Component cooling water heat exchanger A on September 9, 2019

71111.11B - Licensed Operator Requalification Program and Licensed Operator Performance

Licensed Operator Requalification Program (IP Section 03.04) (1 Sample)

(1) Biennial Requalification Written Examinations

The inspectors evaluated the quality of the licensed operator biennial requalification written examinations.

Annual Requalification Operating Tests

The inspectors evaluated the adequacy of the facility licensees annual requalification operating test.

Administration of an Annual Requalification Operating Test

The inspectors evaluated the effectiveness of the facility licensee in administering requalification operating tests required by 10 CFR 55.59(a)(2) and that the facility licensee is effectively evaluating their licensed operators for mastery of training objectives.

Requalification Examination Security

The inspectors evaluated the ability of the facility licensee to safeguard examination material, such that the examination is not compromised.

Remedial Training and Re-examinations

The inspectors evaluated the effectiveness of remedial training conducted by the licensee, and reviewed the adequacy of re-examinations for licensed operators who did not pass a required requalification examination.

Operator License Conditions

The inspectors evaluated the licensees program for ensuring that licensed operators meet the conditions of their licenses.

Control Room Simulator

The inspectors evaluated the adequacy of the facility licensees control room simulator in modeling the actual plant and for meeting the requirements contained in 10 CFR 55.46.

Problem Identification and Resolution

The inspectors evaluated the licensees ability to identify and resolve problems associated with licensed operator performance.

71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance

Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01) (1 Sample)

(1) The inspectors observed and evaluated licensed operator performance in the control room during a period of heightened activity due to an unplanned plant shutdown and cooldown in accordance with Technical Specification 3.0.3 due to excessive leakage in the chemical and volume control system, due to a crack in a drain line weld on July 31, 2019.

Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)

(1) The inspectors observed and evaluated licensed operator performance in the simulator during an evaluated examination on August 20, 2019.

71111.12 - Maintenance Effectiveness

Routine Maintenance Effectiveness Inspection (IP Section 02.01) (2 Samples)

The inspectors evaluated the effectiveness of routine maintenance activities associated with the following equipment and/or safety significant functions:

(1) Main generator and 25 kV distribution system on September 18, 2019
(2) Essential chillers on September 30, 2019

71111.13 - Maintenance Risk Assessments and Emergent Work Control

Risk Assessment and Management Sample (IP Section 03.01) (5 Samples)

The inspectors evaluated the risk assessments for the following planned and emergent work activities:

(1) Emergent work review associated with control element assembly 43 control system failure on July 17, 2019
(2) Risk assessment associated with planned yellow risk due to emergency feedwater pump B maintenance on July 29, 2019
(3) Emergent work review associated with elevated leakage in the chemical and volume control system on July 31, 2019
(4) Risk assessment and emergent work review associated with control element drive motor control system undervoltage relay failure on August 21, 2019
(5) Emergent work review associated with the failure of the auxiliary component cooling water header A component cooling water heat exchanger outlet temperature control valve on September 6, 2019

71111.15 - Operability Determinations and Functionality Assessments

Operability Determination or Functionality Assessment (IP Section 02.02) (3 Samples)

The inspectors evaluated the following operability determinations and functionality assessments:

(1) Operability determination associated with the flow path to the charging pump suction header due to a leak near the volume control tank outlet header drain to the equipment drain tank sump valve on July 10, 2019
(2) Operability determination associated with main generator lockout relays not actuating following a manual turbine trip on August 6, 2019
(3) Operability determination associated with the essential chiller B hot gas bypass valve failing to open on September 27, 2019

71111.18 - Plant Modifications

Temporary Modifications and/or Permanent Modifications (IP Section 03.01 and/or 03.02) (1 Sample)

The inspectors evaluated the following temporary or permanent modifications:

(1) Auxiliary component cooling water wet tower basin level setpoint change on July 17, 2019

71111.19 - Post-Maintenance Testing

Post-Maintenance Test Sample (IP Section 03.01) (5 Samples)

The inspectors evaluated the following post maintenance tests:

(1) Control element assembly subgroup 10 following the replacement of associated control element drive system electrical components on July 22, 2019
(2) Emergency feedwater header A to steam generator 1 backup flow control valve, following valve repacking, on August 4, 2019
(3) Control element drive mechanism control system cabinet 3 undervoltage relay following relay replacement on August 22, 2019
(4) Safety related switchgear 31A following undervoltage relay calibration on September 11, 2019
(5) Emergency diesel generator B following a system maintenance outage on September 23, 2019

71111.20 - Refueling and Other Outage Activities

Refueling/Other Outage Sample (IP Section 03.01) (1 Sample)

(1) The inspectors evaluated the licensee's performance during a forced outage to repair failed piping in the chemical and volume control system from July 31 to August 8, 2019

71111.22 - Surveillance Testing

The inspectors evaluated the following surveillance tests:

Surveillance Tests (other) (IP Section 03.01)

(1) Auxiliary component cooling water pump A Baker test on July 11, 2019
(2) Shutdown cooling heat exchanger A temperature loop calibration on July 18, 2019
(3) Essential chillers A and B component cooling water common header inlet and outlet isolation valves on August 19, 2019
(4) High pressure safety injection pump AB testing on September 17, 2019

Inservice Testing (IP Section 03.01) (1 Sample)

(1) Condensate makeup train A quarterly valve testing on July 16, 2019

71114.06 - Drill Evaluation

Select Emergency Preparedness Drills and/or Training for Observation (IP Section 03.01) (1 Sample)

(1) The inspectors evaluated an emergency preparedness drill on September 25,

RADIATION SAFETY

71124.05 - Radiation Monitoring Instrumentation

Walk Downs and Observations (IP Section 02.01) (1 Sample)

The inspectors evaluated radiation monitoring instrumentation during plant walkdowns.

(1) The inspectors reviewed the following:

Portable Survey Instruments

  • AMP 100 (CHP-ARM014)
  • AMS-4 (CHP-RD-261)
  • LM-177 (CHP-CR-148, CHP-CR-186, CHP-CR-195)
  • Ludlum 9-3 (CHP-DR-286, HP-DR-562, CHP-DR-661)
  • RO-20 (CHP-DR-119)
  • SAC-4 (HP-DS-066)
  • Wide range telepole (CHP-TEL034, CHP-TEL039, CHP-TEL138)

Source Check Demonstration

  • AMS4 (CHP-AMSD-0214)
  • ARGOS 5AB (1410-186)
  • Cronos 4 (1011-061)
  • MGP Small Tool Monitor (89-0527)
  • PM7 (394, 395)

Area Radiation Monitors and Continuous Air Monitors

  • Area Radiation Monitors: ARMIR5103, ARMIR5014, ARMIR5015, ARMIR5018, ARMIR5208
  • Fuel Handling Building Normal Ventilation Radiation Monitor Loop
  • Containment Particulate, Iodine, and Gaseous Monitor

Personnel Contamination Monitors, Portal Monitors and Small Article Monitors

  • ARGOS 5AB (1410-86, 1412-364)
  • Cronos 4 (1011-061, 1412-364)
  • Fastscan (Dosimetry Office, West Side Access)
  • GEM 5 (HP-DS-080, HP-DS-095)
  • PM7 (394, 395)

Calibration and Testing Program (IP Section 02.02) (1 Sample)

The inspectors evaluated the calibration and testing program implementation.

(1) The inspectors reviewed the following:

Alarm Setpoint and Calibration Method Check of Personnel Contamination Monitors, Portal Monitors and Small Article Monitors

  • ARGOS 5AB (1410-186)
  • Cronos4 (1011-061)
  • MGP Small Tool Monitor (89-0527)
  • PM7 (394, 395)

Failure to Meet Calibration or Source Check Acceptance Criteria

  • GEM 5 (1410-190)
  • Ludlum 9-3 (HP-DR-559, HP-DR-562)
  • RO20 (CHP-DR-163)
  • Telepole (CHP-TEL126, CHP-TEL135, CHP-TEL137)

71124.06 - Radioactive Gaseous and Liquid Effluent Treatment

Walk Downs and Observations (IP Section 02.01) (1 Sample)

The inspectors walked down the following gaseous and liquid radioactive effluent monitoring and filtered ventilation systems to assess the material condition and verify proper alignment according to plant design:

(1)

  • Fuel Handling Building Exhaust Gaseous Radiation Monitor (RE-5107)
  • Plant Stack RAB Ventilation Gaseous Radiation Monitor (RE-0100)
  • Turbine Building Industrial Waste Tank Liquid Radiation Monitor (RE-6778)
  • Component Cooling Water Liquid Radiation Monitor (RE-7050)
  • Circwater Discharge Liquid Radiation Monitor (RE-1900)
  • Control Room Emergency Filtration Unit
  • Controlled Ventilation Areas Filter Unit

Calibration and Testing Program (Process & Effluent Monitors) (IP Section 02.02) (1 Sample)

The inspectors reviewed the following gaseous and liquid effluent monitor instrument calibrations and tests:

(1) Gaseous Effluent Radiation Monitors

March 19, 2019

  • WO 52798848, RE-0100.1, RAB Ventilation System / Plant Stack A, June 3, 2019
  • WO 52730813, RE-0648, Gaseous Waste Management System (GWMS),

July 7, 2018

  • WO 52748891, RE-5107A, Fuel Handling Building Ventilation System A, December 3, 2018
  • WO 52719287, RE-5107B, Fuel Handling Building Ventilation System B, March 20, 2018

Liquid Effluent Radiation Monitors

  • WO 52717425, RE-7050B, Component Cooling Water Blowdown, March 12, 2018
  • WO 52721495, RE-1900, Circulating Water Discharge, April 2, 2018

Sampling and Analysis (IP Section 02.03) (1 Sample)

The inspectors reviewed the following sampling and analysis:

(1) Radioactive Effluent Sampling and Analysis Activities
  • Fuel Handling Building Radiation Monitor A and B Filter Changeout, September 17, 2019
  • Fuel Handling Building Radiation Monitor B Tritium Sample, September 17, 2019
  • Plant Stack RAB Ventilation Filter Changeout, September 17, 2019

Effluent Discharges

  • The inspectors were unable to observe any active liquid or gaseous discharge activities, but reviewed numerous permits.

Instrumentation and Equipment (IP Section 02.04) (1 Sample)

The inspectors reviewed the following radioactive effluent discharge system surveillance test results:

(1)

  • WO 52716247, HVC B - Control Room Emergency Filtration Unit Charcoal Sampling, February 14, 2018
  • WO 52716248, HVC B - Control Room Emergency Filtration Unit In-Place Charcoal Testing, February 14, 2018
  • WO 52714811, CVAS B - Controlled Ventilation Areas Filtration Unit In-Place Charcoal Testing, March 15, 2018
  • WO 52767953, CVAS A - Controlled Ventilation Areas Filtration Unit In-Place Charcoal Testing, January 11, 2019
  • WO 52795776, HVC A - Control Room Emergency Filtration Unit In-Place Charcoal Testing, July 9, 2019

Dose Calculations (IP Section 02.05) (1 Sample)

The inspectors reviewed the following to asses public dose:

(1) Gaseous Discharge Permits
  • W3GB2017-151
  • W3GB2018-038
  • W3GB2019-017
  • W3GC2018-063
  • W3GC2018-150
  • W3GC2019-020

Liquid Discharge Permits

  • W3LB2017-269
  • W3LB2018-078
  • W3LB2019-023
  • W3LC2017-267
  • W3LC2018-242
  • W3LC2019-016

Annual Radiological Effluent Release Reports

Abnormal Gaseous or Liquid Tank Discharges

  • None occurred

71124.07 - Radiological Environmental Monitoring Program

Site Inspection (IP Section 02.01) (1 Sample)

The inspectors evaluated the radiological environmental monitoring program implementation.

(1) The inspectors reviewed the following:

Walkdowns, Calibrations, and Maintenance Record Review

Air Samplers

  • APP-1
  • APQ-1
  • APF-1
  • APE-26/30

TLDs

  • P-1
  • Q-1
  • R-1
  • E-1
  • M-1

Environmental Sample Collections and Preparation Observation

  • SWK-1
  • SWE-5
  • SWP-7

Licensee Actions in Response to Missed Sample, Inoperable Sampler, Lost TLD or Anomalous Measurement

  • For both 2017 and 2018, milk was unavailable at the indicator locations, so broadleaf vegetation was collected as a surrogate.
  • In July 2019, air sample pump not running at full capacity, so pump was replaced.
  • In July 2019, the G-8 and K1 thermoluminescent dosimeters (TLD) were missing and replaced with new TLDs.

Sampling Program for the Potential of Licensed Material Entering Groundwater

  • Condensate Storage Tank
  • Spent Fuel Pool

Groundwater Protection Initiative (GPI) Implementation (IP Section 02.02) (1 Sample)

(1) The inspectors evaluated the licensees voluntary groundwater protection initiative.

No additional observations were identified.

71124.08 - Radioactive Solid Waste Processing and Radioactive Material Handling, Storage,

and Transportation

Radioactive Material Storage (IP Section 02.01)

The inspectors evaluated radioactive material storage.

(1) The inspectors toured the following areas:
  • Spent Fuel Pool
  • Cask Storage Pit
  • Low Level Waste Storage Facility

The inspectors performed a container check (e.g., swelling, leakage and deformation)on the following containers:

  • Radwaste and Radioactive Material Containers in the Low Level Waste Storage Facility
  • Spent Fuel Pool Container Inventory
  • Cask Storage Pit Container Inventory

Radioactive Waste System Walkdown (IP Section 02.02) (1 Sample)

The inspectors evaluated the following radioactive waste processing systems [and processes] during plant walkdowns:

(1) Liquid or Solid Radioactive Waste Processing Systems
  • Spent Fuel Pool
  • Cask Storage Pit
  • Low Level Waste Storage Facility

Radioactive Waste Resin and/or Sludge Discharges Processes

  • There were no current or resin and sludge discharge processes being conducted this inspection.

Waste Characterization and Classification (IP Section 02.03) (1 Sample)

The inspectors evaluated the radioactive waste characterization and classification for the following waste streams:

(1)

  • Spent Fuel Pool Operations
  • Storage of Spent Tri-Nuclear Filters
  • Dry Active Waste
  • Spent Resin Transfers

Shipment Preparation (IP Section 02.04) (2 Samples)

The inspectors evaluated [and observed] the following radioactive material shipment preparation processes:

(1) There were no shipments being prepared for transit during this inspection period. However, the details and content of the following spent resin shipment to the licensees waste processor were reviewed:
  • 18-1013, Rx Drain Tank Sludge to Bear Creek
  • 18-1020, RWM Resin to Bear Creek
  • 19-1015, RWM Resin LSA to Bear Creek
  • 19-1019, LWM Resin LSA to Bear Creek

Shipping Records (IP Section 02.05) (1 Sample)

The inspectors evaluated the following non-excepted package shipment records:

(1)

  • ACME Shipment to UniTech Services ORSC
  • 18-3002, Detector ARM RD

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification

The inspectors verified licensee performance indicators submittals listed below:

MS08: Heat Removal Systems (IP Section 02.07)===

(1) July 1, 2018, through June 30, 2019

MS09: Residual Heat Removal Systems (IP Section 02.08) (1 Sample)

(1) July 1, 2018, through June 30, 2019

MS10: Cooling Water Support Systems (IP Section 02.09) (1 Sample)

(1) July 1, 2018, through June 30, 2019

71152 - Problem Identification and Resolution

Semiannual Trend Review (IP Section 02.02) (1 Sample)

(1) The inspectors reviewed the licensees corrective action program for potential adverse trends that might be indicative of a more significant safety issue. The inspectors identified an observation and associated minor violation related to the licensees treatment of repetitive issues with subgroup 10 of the control element drive mechanism control system documented in the Inspection Results section of this report.

71153 - Follow-up of Events and Notices of Enforcement Discretion Event Report (IP Section 03.02)

The inspectors evaluated the following licensee event reports (LERs):

(1) LER 05000382/2019-004-00, Boron Dilution Alarm (Startup Channel High Neutron Flux) Inoperable Resulting in Operation or Condition Prohibited by Technical Specifications (ADAMS Accession: ML19129A439). The inspectors documented a licensee identified violation associated with this LER in the inspection results section of this report.
(2) LER 05000382/2019-005-00, Automatic Reactor Scram due to Steam Generator 1 High Level Resulting from a Main Turbine Trip and Subsequent Reactor Power Cutback due to Failed Diode Modules within the Main Exciter (ADAMS Accession:

ML19196A346). The circumstances surrounding this LER are documented in the Inspection Results section of this report.

INSPECTION RESULTS

Failure to Periodically Calibrate Radiation Monitoring Equipment Cornerstone Significance Cross-Cutting Aspect Report Section Occupational Radiation Safety

Green NCV 05000382/2019003-01 Open/Closed

[H.3] - Change Management 71124.05 The inspectors identified a Green NCV of 10 CFR 20.1501(c) for failure to periodically calibrate area radiation monitoring equipment used to perform dose rate measurements.

Specifically, on or around January 18, 2012, the licensee began changing the periodic calibrations of area radiation monitors without verifying the instruments were in calibration.

Description:

During a review of calibration records for four area radiation monitors (ARMIR5013, ARMIR5014, ARMIR5015 and ARMIR5018), the inspectors identified the monitors last had a detector calibration on November 18, 2009, November 13, 2009, October 28, 2009, and November 19, 2009, respectively. Upon further review, the inspectors identified that on January 18, 2012, the licensee initiated an Action Request (AR 133414133414 to increase the radiation detector calibration frequency for these area radiation monitors from 2R (three years) to 4R (six years), where R represents a refueling cycle of 18 months. The licensee again extended the calibration frequency of the radiation detectors another time from 4R to 6R (nine years): AR 195165195165dated November 18, 2014, for ARMIR5013 and ARMIR5014; AR 213067213067 dated March 24, 2015, for ARMIR5015; and AR 267979267979 dated February 6, 2017, for ARMIR5018. For each of the frequency extensions, the licensee did not calibrate nor verify the calibration was acceptable before extending the calibration frequency.

These four area radiation monitors are listed in the licensees Final Safety Analysis Report (FSAR), Chapter 12, Table 12.3-2, and are used, in part, to

(1) measure ambient gamma radiation and to indicate to operations personnel the ambient gamma radiation in specific areas of the plant;
(2) annunciate and warn of abnormal radiation levels in specific areas of the plant;
(3) provide base data in controlling access of personnel to radiation areas;
(4) warn of uncontrolled or inadvertent movement of radioactive material in the plant;
(5) provide local indication and alarms at key points where a substantial change in radiation levels might be of immediate importance to personnel frequenting the area; and
(6) furnish information for making radiation surveys. Additionally, a specific note for these monitors in Table 12.3-2 of the FSAR points out these monitors are used by Radiation Protection during shutdown for personnel protection.

The inspectors determined the preventative maintenance program, as described in licensee Procedure EN-DC-324, Preventative Maintenance Program, Revision 22, does not prescriptively include the involvement of radiation protection within its program or process. By not including a member from the Radiation Protection organization during the calibration frequency change process for these four area radiation monitors, the licensee personnel implementing the changes failed to fully understand the area radiation monitor functions, as described in the FSAR, and how they related to Title 10 of the Code of Federal Regulations (10 CFR) Part 20, Standards for Protection Against Radiation, Subpart F, Surveys and Monitoring.

Corrective Actions: The licensee entered the issue in the corrective action program to re-evaluate and document an adequate basis for the calibration frequency change of monitors ARMIR5013, ARMIR5014, ARMIR5015, and ARMIR5018.

Corrective Action References: Condition Report CR-WF3-2019-07366

Performance Assessment:

Performance Deficiency: The failure to periodically calibrate area radiation monitoring instruments used to evaluate dose rate measurements as required by 10 CFR Part 20 was a performance deficiency.

Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the plant facilities/equipment and instrumentation attribute of the Occupational Radiation Safety Cornerstone and adversely affected the cornerstone objective to ensure the adequate protection of the worker health and safety from exposure to radiation from radioactive material during routine civilian nuclear reactor operation.

Specifically, the licensee failed to calibrate or verify the calibration of four area radiation monitors prior to extending their calibration frequency. As a result, the failure to calibrate or verify the calibration of the four area radiation monitors impacts the licensees ability to ensure accurate radiation measurements.

Significance: The inspectors assessed the significance of the finding using Appendix C, Occupational Radiation Safety SDP. The finding was:

(1) not related to as low as is reasonably achievable planning,
(2) did not involve an overexposure or
(3) did not involve a substantial potential for overexposure, and
(4) the ability to assess dose was not compromised. Therefore, the inspectors determined the finding to be of very low safety significance (Green).

Cross-Cutting Aspect: H.3 - Change Management: Leaders use a systematic process for evaluating and implementing change so that nuclear safety remains the overriding priority.

The finding had a cross-cutting aspect in the area of human performance associated with change management because the licensees change process did not identify that the instrument calibration requirements of 10 CFR Part 20 were applicable to area radiation monitors. Specifically, the change process did not involve an adequate systematic process to include members of the radiation protection organization to ensure compliance of 10 CFR Part 20 were maintained. Although these changes were made effective in 2012, there were recent opportunities for the licensee to evaluate the changes and/or ensure the affected monitors were appropriately calibrated due to multiple condition reports reviewed relative to the performance of these monitors.

Enforcement:

Violation: Title 10 CFR 20.1501(c) requires, in part, the licensee ensure that instruments used for quantitative radiation measurements (e.g., dose rate and effluent monitoring) are calibrated periodically for the radiation measured.

Contrary to the above, on or around January 18, 2012, the licensee failed to ensure that instruments used for quantitative radiation measurements (e.g., dose rate and effluent monitoring) are calibrated periodically for the radiation measured. Specifically, the licensee began changing the periodic calibrations of area radiation monitors without verifying the instruments were currently calibrated and may be adequately used for dose rate measurements of plant areas.

Enforcement Action: This violation is being treated as an NCV, consistent with Section 2.3.2 of the Enforcement Policy.

Quantity of Radioactive Material Shipment Error Unresolved Item (Open)

Unresolved Item URI 05000382/2019003-02 71124.08

Description:

While reviewing the circumstances associated with a solid radwaste/radioactive material (SRW/RAM) transportation event that was identified on May 1, 2019, the inspectors identified several issues of concern related to compliance with certain regulatory requirements, such as, 10 CFR Part 37 and 10 CFR 71.5. The inspectors identified that during a period from April 2-17, 2019, the licensee unknowingly mischaracterized, relocated, prepared, and shipped offsite Category 2 radioactive material quantities of concern (RAMQC). On April 17, 2019, the licensee sent a radioactive waste shipment (19-1015) to a waste processor in Tennessee. The shipment left the site with inaccurate information relative to the total weight and radioactivity amounts on the waste manifest shipping papers. The waste manifest (NRC Forms 540 and 541) accompanying the shipment indicated that shipment 19-1015 contained a total of 8.32 Curies; however, it actually contained 79.2 Curies.

The licensee became aware of the problem with this shipment because their waste processor questioned the net weight of the shipment upon its arrival at their facility. On May 1, 2019, Energy Solutions, located in Oak Ridge, Tennessee, received a shipment of spent resin from Waterford, Unit 3, for processing. The weight of the container was determined to be significantly different from the weight listed on the manifest. Specifically, the manifest indicated the container weighed approximately 742 lbs. When Energy Solutions weighed the container upon receipt, it weighed 6,550 lbs. Waterford, Unit 3, was notified of the inaccuracy of the weight in the manifest, and after revising the weight-based calculated activities for the radionuclides, the licensee provided a revised manifest to Energy Solutions. The original manifest indicated a total package activity of 8.2 Ci, of which 2.1 Ci was Co-60. The revised and corrected manifest specified a total package activity of 72.9 Ci, including 18.7 Ci of Co-60. This radioactivity amount exceeded the Category 2 limits (8.2 Ci) for security concerns under 10 CFR Part 37. Additionally, the licensee had stored, prepared, and shipped offsite RAMQC into the public domain which appeared to be in non-compliance with 10 CFR 71.5 in the implementation of DOT regulations 49 CFR 172.203(d)(3), Subpart C and 49 CFR 172.800 and 802, Subpart I.

These issues of concern require additional information and review to determine whether the preparation and shipment of RAMQC constituted violations of NRC requirements.

Consequently, we are considering this matter as an Unresolved Item (URI).

Planned Closure Actions: The NRC inspectors plan to continue their review of documents provided by the licensee, as they are made available. This review will be a comprehensive assessment of all associated violations and/or findings related to this shipping occurrence of incorrectly calculating the weighted-activities of radionuclides and improperly characterizing the shipment.

Licensee Actions: The licensee placed this matter into their corrective action program for review. The inspectors did not perceive any immediate safety or security concerns.

Corrective Action References: CR-WF3-2019-04477, CR-WF3-2019-07307, CR-WF3-2019-07312

Observation: Semi-Annual Trend Review Associated with the Control Element Drive Mechanism Control System 71152 The inspectors identified an adverse trend involving operability reviews for repetitive failures involving subgroup 10 of the control element drive mechanism control system. From April 29, 2019, through September 9, 2019, the licensee initiated 18 condition reports involving apparent repetitive failures of control element assemblies in subgroup 10 that caused the assemblies to become immovable, but remain trippable. Each condition report affected at least one of the four control element assemblies in subgroup 10. In each instance, the licensee declared the affected rods inoperable and took the actions required by Technical Specification 3.1.3.1, Moveable Control Assemblies.

After six of the condition reports were generated, the inspectors noted that for each identified condition, the licensee reviewed the impact of the condition on the individually affected control element assemblies and made the appropriate operability determination, but the licensee did not review the impact of the aggregate conditions on the operability of subgroup 10 overall.

The licensee addressed the operability of equipment using licensee procedure EN-OP-104, Operability Determination Process, Revision 16. Section 8.10.11 of EN-OP-104 specifically addresses reduced reliability as a degraded or nonconforming condition. Section 8.10.11 requires that the licensee review repetitive failures and, if reliability has been reduced, to consider the equipment degraded or non-conforming and assess its operability.

The inspectors questioned the licensee regarding the operability of subgroup 10 given the guidance in Section 8.10.11 of EN-OP-104. Due to inspector questioning, the licensee reclassified subgroup 10 as operable but degraded or non-conforming due to reduced reliability in condition report CR-WF3-2019-05729. The licensee concluded that subgroup 10 was still capable of performing its safety function to insert control element assemblies into the reactor core.

The inspectors determined that the licensees failure to address the impact of reduced reliability on the operability of subgroup 10 as required by EN-OP-104 was a minor violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings. The licensees cause evaluation for the underlying conditions leading to the repetitive failures of subgroup 10 is still ongoing. The inspectors will document any findings related to the underlying condition in a future inspection report.

Failure to Implement Procedures for Main Generator Exciter Maintenance Cornerstone Significance Cross-Cutting Aspect Report Section Initiating Events

Green FIN 05000382/2019003-03 Open

[H.5] - Work Management 71153 The inspectors reviewed a self-revealed Green finding because the licensee did not follow procedure requirements when performing periodic maintenance on the main generator exciter. Specifically, the licensee did not implement the preventative maintenance steps required by procedure ME-004-003, Main Exciter, Revisions 300 through 303, to perform inspection, cleaning, and testing of the main exciter during refueling outages.

Description:

On May 16, 2019, the Waterford, Unit 3, main generator automatically tripped as designed following a loss of excitation field. As part of their troubleshooting, the licensee disassembled the main exciter and discovered that the rotating rectifier had 13 of the 72 outboard fuses failed, 12 of the 36 outboard diodes failed, 2 additional outboard diodes arced and shorted between phases, and one of the 36 inboard diodes failed. The design of the rotating rectifier is to operate at full capacity with up to two diodes per phase out of service. In addition to the component failures, the licensee discovered excessive dirt and debris buildup in the interior of the rotating rectifier.

The licensee established a preventative maintenance program for the main exciter that required the main exciter to be sent offsite to a specialist vendor for major refurbishment every 8 years. This was last performed as part of the refueling outage in 2012. The licensees preventative maintenance program also required minor refurbishment be performed on the main exciter during refueling outages where major refurbishment was not performed. The licensee accomplished this minor refurbishment using licensee Procedure ME-004-003, Main Exciter. Procedure ME-004-003 provides instructions for maintenance and testing of the main exciter, including instructions to ensure electrical and mechanical integrity of the rotating rectifier and its components. The licensee scheduled the minor refurbishment tasks using procedure ME-004-003 during refueling outages in 2014, 2015, 2017, and 2019.

In their review of the past maintenance on the main generator exciter, the licensee found that large portions of procedure ME-004-003 were not performed. During refueling outages 19, 20, 21, and 22, electrical maintenance personnel only inspected the rectifier wheel fuses and cleaned accessible portions of the exciter. Since the main generator exciter was not fully disassembled when Procedure ME-004-003 was performed during those refueling outages, the steps to clean, inspect, and test the internal components of the main exciter were marked as not applicable and not performed. In each instance, electrical maintenance personnel documented the concurrence of systems engineering personnel to not perform the applicable portions of Procedure ME-004-003.

Licensee Procedure EN-HU-106, Procedure and Work Instruction Use and Adherence, Revisions 3 through 7, is used to control when personnel may mark procedural steps as not applicable. Section 7.1.3 of Procedure EN-HU-106 only allows the use of not applicable when doing so does not change the intent of the steps or sections.

Prior to performing Procedure ME-004-003, electrical maintenance personnel requested guidance from systems engineering personnel for which portions were required. Systems engineering personnel advised that the scope of work should be based off the previous refueling outages. System engineering personnel did not confirm the adequacy of the scope of maintenance performed during previous outages. Additionally, electrical maintenance personnel did not ensure that marking sections of Procedure ME-004-003 as not applicable did not change the intent of the steps or sections.

Corrective Actions: The licensees immediate corrective action was to disassemble and clean the main generator exciter, and to either repair or replace the failed components associated with the rotating rectifier. Long term corrective actions include revising the preventative maintenance strategy and procedures to ensure the correct scope of maintenance is included in both the 8-year major and every refueling cycle minor refurbishments.

Corrective Action References: CR-WF3-2019-04788

Performance Assessment:

Performance Deficiency: The failure to implement the requirements of Procedure ME-004-003 when required by the preventative maintenance program was a performance deficiency.

Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the equipment performance attribute of the Initiating Events Cornerstone and adversely affected the cornerstone objective to limit the likelihood of events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Specifically, the failure to perform maintenance in accordance with Procedure ME-004-003 to ensure the integrity and cleanliness of internal components of the main generator exciter resulted in an electrical fault that caused an automatic trip of the main turbine and generator.

Significance: The inspectors assessed the significance of the finding using Appendix A, The Significance Determination Process (SDP) for Findings At-Power. Using IMC 0609, Appendix A, Exhibit 1, Initiating Events Screening Questions, the inspectors determined the finding to be of very low safety significance (Green) because the finding did not cause a reactor trip and the loss of mitigation equipment relied upon to transition the plant from the onset of the trip to a stable shutdown condition.

Cross-Cutting Aspect: H.5 - Work Management: The organization implements a process of planning, controlling, and executing work activities such that nuclear safety is the overriding priority. The work process includes the identification and management of risk commensurate to the work and the need for coordination with different groups or job activities. Specifically, the licensee did not implement the process of controlling and executing work activities controlled by Procedure EN-HU-104 when personnel implementing Procedure ME-004-003 regularly marked large sections as not applicable which changed the intent of the sections.

Enforcement:

Inspectors did not identify a violation of regulatory requirements associated with this finding.

LER (Discussed)

Automatic Reactor SCRAM due to Steam Generator 1 High Level Resulting from a Main Turbine Trip and Subsequent Reactor Power Cutback due to Failed Diode Modules within the Main Exciter LER 05000382/2019-005-00 71153

Description:

On May 16, 2019, the Waterford main generator automatically tripped as designed following a loss of excitation field. Following the trip, the reactor power cutback system actuated as designed to reduce reactor power. Following the reactor power cutback, the reactor automatically tripped due to high feedwater level in steam generator 1. The inspectors documented a Green finding in this report related to the cause of the automatic main generator trip. The cause evaluation of the subsequent automatic reactor trip due to high steam generator level is still ongoing and will be documented in a later inspection report.

Licensee-Identified Non-Cited Violation 71153 This violation of very low safety significance was identified by the licensee and has been entered into the licensee corrective action program and is being treated as an NCV, consistent with Section 2.3.2 of the Enforcement Policy.

Violation: Technical Specification 3.1.2.9, Boron Dilution, requires, in part, that with one boron dilution alarm inoperable and the primary makeup water flow path to the reactor coolant system not isolated, determine reactor coolant system boron concentration within one hour. Contrary to the above, on March 10, 2019, with one boron dilution alarm inoperable and the primary makeup water flow path to the reactor coolant system not isolated, the licensee did not determine reactor coolant system boron concentration within one hour.

On March 10, 2019, startup channel 1, one of the boron dilution alarms, was de-energized and rendered inoperable during the performance of surveillance testing at approximately 3:30 p.m. on March 10, 2019. The licensee identified that startup channel 1 was de-energized while taking Technical Specification logs and re-energized startup channel 1 on March 10, 2019, at 11:18 p.m., exceeding the Technical Specification 3.1.2.9 allowed outage time by approximately 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />.

Significance/Severity: The finding was of very low safety significance, Green, in accordance with Inspection Manual Chapter 0609, Appendix G, Attachment 1, Exhibit 3, Mitigating Systems Screening Questions because the loss of the boron dilution alarms did not represent the actual loss of a safety function.

Corrective Action References: CR-WF3-2019-03161

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On September 19, 2019, the inspectors presented the Public Radiation Safety exit meeting inspection results to Mr. B. Lanka, Acting Site Vice President, and other members of the licensee staff.
  • On September 24, 2019, the inspectors presented the 2019003 Biennial Requalification telephonic exit debrief inspection results to Mr. V. Ford, Operations Training Superintendent, and other members of the licensee staff.
  • On October 10, 2019, the inspectors presented the integrated inspection results to Mr. S. Vazquez, Site Vice President, and other members of the licensee staff.
  • On October 17, 2019, the inspectors presented the Final Exit Meeting for Radiation Safety Inspection results to Mr. S. Vazquez, Site Vice President, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.01

Calculations

ECM15-004

Waterford FLEX Internal Flooding Calculation

MNQ3-5

Flooding Analysis Outside Containment

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2018-06958, 2019-03900, 2019-05201

Procedures

OP-901-521

Severe Weather and Flooding

71111.04Q Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-04798, 2019-03258

Procedures

OP-002-001

Auxiliary Component Cooling Water

315

OP-003-035

Auxiliary Feedwater

310

OP-009-002

Emergency Diesel Generator

351

OP-009-003

Emergency Feedwater

309

71111.05Q Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-03742, 2019-05956

Miscellaneous

NS-TB-002

Turbine Building +15.00' West including Feedwater Pump

"A" Auxiliary Feedwater Pump, Main Lube Oil Storage Tank

and Condensate Pump

Procedures

EN-TQ-125

Fire Brigade Drills

FP-001-019

Fire Brigade Equipment

310

FP-001-020

Fire Emergency/Fire Report

2

RAB 13-001

Battery Room 3A

RAB 1A, B, C, D-

001

Control Room, H&V Room, Emergency Living Quarters and

Computer Room

RAB 8B,E,F-001

Switchgear Room B

RAB 8C-001

Switchgear Room A/B

ROOF W-001

Roof W (MSIV A)

UNT-005-013

Fire Protection Program

71111.06

Calculations

ECM05-004

Required Isolation Time to Prevent Depletion of CCW Surge

Tank due to SSE

ECM15-004

Waterford FLEX Internal Flooding Calculation

MNQ3-5

Flooding Analysis Outside Containment

PRA-W3-01-002

W3 Internal Flooding Analysis

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-01724, 2019-01719

Procedures

OP-002-004

Chilled Water System

317

71111.07A

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2018-05404, 2018-06396, 2018-07109, 2019-2164

Procedures

CE-002-003

Maintaining Auxiliary Component Cooling Water Chemistry

306

CE-002-007

Maintaining Component Cooling Water Chemistry

309

71111.11B

Corrective Action

Documents

Control Room

Condition Report

Summary for

2018-2019

Control Room Condition Report Summary for 2018-2019

06/25/2019

Miscellaneous

Simulator

Differences List

Simulator Differences List

June 26,

2019

Simulator

Discrepancy

Report July 2017

to July 2019

Simulator Discrepancy Report July 2017 to July 2019

07/02/2019

Waterford 2019

Requalification

Exam Week 1 - 3

Operations Exam

07/29/2019

Waterford 2019

Requalification

Exam Week 1 - 3

Written Exam

07/29/2019

Procedures

EN-TQ-114

Licensed Operator Requalification Training Program

Description

EN-TQ-201

Systematic Approach to Training Process

Revision 23

EN-TQ-202

Simulator Configuration Control

Revision 10

EN-TQ-210

Conduct of Simulator Training

Revision 15

EN-TQ-217

Examination Security

Revision 8

OI-024-000

Maintaining Active SRO-RO Status

314

TQF-202-SBT

Scenario Based Testing Checklist

Revision 1

TQF-210-DD03

LOR Simulator Crew performance Evaluation Grading

Criteria

Revision 5

WSIM-DIR-002

Simulator Core Reload Acceptance Test

Revision 4

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.11Q Miscellaneous

WSXM-LOR-

194EXM

2019 Cycle 4 Biennial Simulator Exam Week 5

Procedures

OP-010-005

Plant Shutdown

336

OP-010-006

Outage Operations

333

OP-901-113

Volume Control Tank Makeup Control Malfunction

305

OP-901-311

Loss of Train B Safety Bus

2

OP-902-000

Standard Post Trip Actions

OP-902-003

Loss of Offsite Power/Loss of Forced Circulation Recovery

71111.12

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2017-05763, 2017-05844, 2019-04788, 2019-04813, 2019-

04848, 2019-07376

Procedures

EN-DC-203

Maintenance Rule Program

EN-DC-204

Maintenance Rule Scope and Basis

EN-DC-205

Maintenance Rule Monitoring

71111.13

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-06375

Procedures

EN-OU-108

Shutdown Safety Management Program (SSMP)

EN-WM-104

On Line Risk Assessment

OI-37-000

Operations Risk Assessment Guideline

313

Work Orders

2790245

71111.15

Calculations

SI Calculation

1900769.301

Evaluation of Leaking 1-inch Line Upstream of Valve CVC-

186

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-05704, 2019-05755, 2019-06307, 2019-07242, 2019-

07462

Miscellaneous

BOP-RT-19-001

Digital Radiographic Examination

07/09/2019

BOP-VT-19-019

Visual Examination of Welds

07/09/2019

Procedures

EN-OP-104

Operability Determination Process

71111.18

Calculations

EC 102-001

Ultimate Heat Sink Margin Restoration - WCT Basin Level

Setpoint Change - Train A

EC 64016

COLSS Analysis/Station Interface Calculation

ECI91-005

Wet Cooling Tower Basin Water Level Instrumentation

Loops Uncertainty Calculation

MN(Q)-9-38

Capacity of Wet Cooling Tower Basins

Drawings

B425 L7079A

ACC - WET COOLING TOWER A BASIN WATER LEVEL

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Miscellaneous

DEIC-I-502

Setpoint and Uncertainty Determination

EC 52043

Ultimate Heat Sink Margin Restoration

71111.19

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-06374

Procedures

EN-OP-104

Operability Determination Process

ME-003-318

G.E. Undervoltage Relay Model 12IAV55C

306

ME-007-036

G.E. Auxiliary Relays 12HFA51B and 12HFA151B7F

306

OP-903-005

Control Element Assembly Operability Check

OP-903-121

Safety Systems Quarterly IT Valve Tests

Work Orders

00528219, 00529055, 52811969, 530144

71111.20

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-06358, 2019-06379, 2019-06384

Procedures

EN-OM-119

On-Site Safety Review Committee

EN-OU-108

Shutdown Safety Management Program (SSMP)

OP-003-033

Main Feedwater

25

OP-003-035

Auxiliary Feedwater

310

OP-010-003

Plant Startup

349

OP-010-006

Outage Operations

333

71111.22

Calculations

ECP96-007

Auxiliary Component Cooling Water Supply and Return

Piping

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-06518, 2018-01724, 2018-01719

Procedures

EN-MA-135

Online Motor Electrical Testing

MI-005-219

Calibration Check and Verification of Thermocouples and

RTDs

304

OP-903-119

Secondary Auxiliaries Quarterly IST Valve Test

Work Orders

2798924, 52877149, 52814428

71114.06

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-07397, 2019-07422, 2019-07424, 2019-07445, 2019-

07449, 2019-07450, 2019-07451, 2019-07467

Procedures

EP-001-001

Recognition & Classification of Emergency Conditions

EP-001-020

Alert

310

EP-001-030

Site Area Emergency

309

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

EP-001-040

General Emergency

310

OP-010-005

Plant Shutdown

337

OP-901-102

CEA or CEDMCS Malfunction

305

OP-901-212

Rapid Plant Power Reduction

OP-901-402

High Airborne Radioactivity in Reactor Auxiliary Building

OP-901-410

High Activity in Reactor Coolant System

OP-901-512

Loss of Turbine Cooling Water

OP-902-000

Standard Post Trip Actions

OP-902-001

Reactor Trip Recovery

OP-902-007

Steam Generator Tube Rupture Recovery Procedure

71124.05

Calibration

Records

2018-B2.28-

CALDAT-04015

Portable Instrumentation Calibration Data Sheet: Ludlum

LM-177 (CHP-CR-186)

10/01/2018

2018-B2.28-

CALDAT-05747

Portable Instrumentation Calibration Data Sheet: AMP100

(CHP-ARM014)

09/06/2018

2018-B2.28-

CALDAT-06937

Portable Instrumentation Calibration Data Sheet: Wide

Range Telepole (CHP-TEL034)

10/10/2018

2018-B2.28-

CALDAT-06939

Portable Instrumentation Calibration Data Sheet: Wide

Range Telepole (CHP-TEL039)

10/10/2018

2018-B2.28-

CALDAT-07490

Portable Instrumentation Calibration Data Sheet: RO-20

(CHP-DR-119)

11/14/2018

2018-B2.28-

CALDAT-08281

Portable Instrumentation Calibration Data Sheet: Ludlum

LM-177 (CHP-CR-195)

2/18/2018

2018-B2.28-

CALDAT-08396

Portable Instrumentation Calibration Data Sheet: AMS-4

Particulate Detector (HP-RD-261)

2/27/2018

2019-B2.28-

CALDAT-00247

Portable Instrumentation Calibration Data Sheet: SAC-4

(HP-DS-066)

01/08/2019

2019-B2.28-

CALDAT-03118

Portable Instrumentation Calibration Data Sheet: Ludlum

LM-177 (CHP-CR-148)

04/11/2019

2019-B2.28-

CALDAT-03128

Portable Instrumentation Calibration Data Sheet: Wide

Range Telepole (CHP-TEL138)

04/15/2019

2019-B2.28-

CALDAT-03199

Portable Instrumentation Calibration Data Sheet: Ludlum 9-3

(CHP-DR-286)

04/16/2019

2019-B2.28-

CALDAT-03211

Portable Instrumentation Calibration Data Sheet: Ludlum 9-3

(HP-DR-562)

04/17/2019

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

2019-B2.28-

CALDAT-04802

Portable Instrumentation Calibration Data Sheet: Ludlum 9-3

(CHP-DR-661)

08/20/2019

ARGOS

Calibration Data

Sheet HP-DS-077

ARGOS Calibration Data Sheet: HP-DS-077, Westside

Access

5/8/2019

ARGOS

Calibration Data

Sheet HP-DS-098

ARGOS Calibration Data Sheet: HP-DS-098, Westside

Access

05/07/2019

Canberra GEM-5

Calibration Sheet

HP-DS-080

Canberra GEM-5 Calibration Sheet HP-DS-080, Westside

Access

07/10/2019

Canberra GEM-5

Calibration Sheet

HP-DS-095

Canberra GEM-5 Calibration Sheet HP-DS-095, PAP

10/30/2018

CRONOS

Calibration Data

Sheet HP-DS-090

CRONOS Calibration Data Sheet: HP-DS-090, Westside

Access

3/26/2019

CRONOS

Calibration Data

Sheet HP-DS-091

CRONOS Calibration Data Sheet: HP-DS-091, Westside

Access

08/12/2019

Fastscan

2019 Fastscan Recalibration Waterford 3 West Side Access

07/14/2019

Fastscan

2019 Fastscan Recalibration Waterford 3 Dosimetry Office

07/14/2019

Corrective Action

Documents

CR-WF3-YYYY-

NNNNN

2017-09300; 2017-09392; 2017-09662; 2018-00104; 2018-

239; 2018-00362; 2018-00547; 2018-00983; 2018-01348;

2018-01371; 2018-02007; 2018-02085; 2018-02917; 2018-

03146; 2018-03680; 2018-03868; 2018-05670; 2018-05842;

2018-06684; 2019-00461; 2019-00780; 2019-01532; 2019-

03504; 2019-03529; 2019-03899; 2019-04105; 2019-04407;

2019-04624

Miscellaneous

Results of the Radiochemistry Cross Check Program -

Entergy Waterford 4 - 2nd Quarter 2019

07/24/2019

Results of the Radiochemistry Cross Check Program -

Entergy Waterford 4 - 3rd Quarter 2018

11/27/2018

Results of the Radiochemistry Cross Check Program -

10/04/2017

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Entergy Waterford 4 - 2nd Quarter 2017

Instrument Source Checking Source Inventory

09/11/2019

2018-B2.28-

LABSTN-0004

Laboratory Standard - Calibration/verification Data: V-570

Meter

06/12/2018

2018-B2.28-

SRCVER-0006

Source Verification: MODEL-89 (400) Serial Number: 2414-

SRC1993001

2/18/2018

TD-G063.0115

General Atomic Area Radiation Monitoring Systems

Equipment Manual E-115-930

2/10/1987

Procedures

EN-CY-102

Laboratory Analytical Quality Control

EN-CY-102-01

Quality Control for Analytical Laboratory Interlab and Intralab

Cross-Check Programs

EN-CY-102-02

Analytical Method Development Quality Assurance

EN-CY-102-03

Calculation Guide for Laboratory QAQC

EN-DC-153

Preventive Maintenance Component Classification

EN-DC-204

Maintenance Rule Scope and Basis

EN-DC-324

Preventive Maintenance Program

MI-005-906

RADIATION MONITORING SYSTEM DESK GUIDE

MI-005-923

Calibration Procedure - General Atomic Area Radiation

Monitor Assemblies 0359-360: ARMIR5013, 5014, 5015,

5018

Self-Assessments LO-WLO-2017-

0032

Pre-NRC Self-Assessment IP 71124.05 Radiation Monitoring

Instrumentation

09/20/2017

LO-WLO-2019-

0015

Pre-NRC Self-Assessment, IP71124.05 Radiation Monitoring

Instrumentation

07/18/2019

Work Orders

WO-WF3-

180572; 180573; 425005; 470721; 485439; 495141;

519720; 51693877; 52329961; 52668978; 52675543;

2739065; 52743583; 52745414; 52759169; 52780184;

2780545; 52780748; 52781284; 52782394;

2782394; 52878443

71124.06

Calibration

Records

WO52717425

Component Cooling Water Blowdown (RE-7050B)

03/12/2018

WO52719287

Fuel Handling Building Ventilation System B (RE-5107B)

03/20/2018

WO52721495

Circulating Water Discharge (RE-1900)

04/02/2018

WO52730813

Gaseous Waste Management System (GWMS) (RE-0648)

07/16/2018

WO52734471

Dry Cooling Tower Sump B (RE-6776)

06/21/2018

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

WO52748891

Fuel Handling Building Ventilation System A (RE-5107A)

2/03/2018

WO52773476

Turbine Building Industrial Waste Sump (RE-6778)

05/06/2019

WO52776602

Main Condenser Evacuation System (MCES) (RE-002)

03/19/2019

WO52798848

RAB Ventilation System/Plant Stack A (RE-0100.1)

06/03/2019

Corrective Action

Documents

CR-HQN-YYYY-

NNNNN

2017-00319

CR-WF3-YYYY-

NNNNN

2017-08186; 2017-09325; 2017-09736; 2018-00983; 2018-

2000; 2018-02007; 2018-03972; 2019-04516; 2019-04712;

2019-06735; 2019-006736; 2019-06737; 2019-06748

Miscellaneous

2018 Annual Radioactive Effluent Release Report

2018

Results of Radiochemistry Cross Check Program - 4th

Quarter 2018

05/13/2019

Results of Radiochemistry Cross Check Program - 3rd

Quarter 2018

11/27/2018

Results of Radiochemistry Cross Check Program - 2nd

Quarter 2019

08/12/2019

2017 Annual Radioactive Effluent Release Report

2017

Results of Radiochemistry Cross Check Program - 4th

Quarter 2017

07/11/2018

W3GB2017-151

Containment Gas Effluent Release Report - Batch

2/20/2017

W3GB2018-038

Containment Gas Effluent Release Report - Batch

03/22/2018

W3GB2019-017

Miscellaneous Gas Effluent Release Report - Batch

2/22/2019

W3GC2018-063

Plant Stack Gas Effluent Release Report - Continuous

05/17/2018

W3GC2018-150

Main Condenser Evacuation System (MCES) Gas Effluent

Release Report - Continuous

11/29/2018

W3GC2019-020

Fuel Handling Building (FHB) Gas Effluent Release Report -

Continuous

2/19/2019

W3LB2017-269

Boric Acid Condenser Tank C Liquid Effluent Release

Report - Batch

2/01/2017

W3LB2018-078

Liquid Waste Management Liquid Effluent Release Report -

Batch

05/12/2018

W3LB2019-023

Steam Generator Blowdown Liquid Effluent Release Report -

Batch

01/29/2019

W3LC2017-267

Turbine Building Industrial Waste System (TBIWS) Liquid

2/04/2017

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Effluent Release Report - Continuous

W3LC2018-242

Turbine Building Industrial Waste System (TBIWS) Liquid

Effluent Release Report - Continuous

01/01/2019

W3LC2019-016

Dry Cooling Tower Sump 1 (DCTS1) Liquid Effluent Release

Report - Continuous

01/01/2019

Procedures

CE-001-004

Periodic Analysis Scheduling Program

318

CE-003-509

Routine Filter Replacement and Grab Sampling on

Particulate Iodine Gas (PIG) Monitors and Wide Range Gas

Monitors (WRGMs)

308

CE-003-512

Liquid Radioactive Waste Release Permit (Manual)

2

CE-003-513

Gaseous Radioactive Waste Release Permit (Manual)

304

CE-003-514

Liquid Radioactive Waste Release Permit (Computer)

303

CE-003-515

Gaseous Radioactive Waste Release Permit (Computer)

304

CE-003-516

Calculation and Adjustment of Radiation Monitoring

Setpoints

2

CE-003-700

General Grab Sampling Techniques

316

MI-003-368

Fuel Handling Building Ventilation System Normal Effluent

Exhaust A or B Particulate and Gaseous Radiation Monitor

Calibration PRMIR5107.A or PRMIR5107.B

016

MI-003-380

Plant Vent Stack Safety Channel A or B Particulate and

Gaseous Radiation Monitor Calibration PRMIR0100.1 or

PRMIR0100.2

309

MI-003-466

Dry Cooling Tower Sumps Liquid Effluent Radiation Monitor

Channel Calibration PRMIR6775 or PRMIR6776

308

MI-003-469

Turbine Building Industrial Waste Sumps Combined

Discharge Liquid Effluent Radiation Monitor Channel

Calibration PRMIR6778

013

MI-003-471

Circulating Water Discharge Liquid Effluent Radiation

Monitor Channel Calibration PRMIR1900

011

MI-003-473

Gaseous Waste Management Discharge Noble Gas

Radiation Monitor Channel Calibration PRMIR0648

305

UNT-005-014

Offsite Dose Calculation Manual

307

Self-Assessments LO-WLO-2019-

0016

Pre-NRC Assessment of Radiation Safety Inspection Criteria

08/07/2019

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Work Orders

WO-52714811

CVAS B - Controlled Ventilation Areas Filtration Unit In-

Place Charcoal Testing

03/15/2018

WO-52716247

HVC B - Control Room Emergency Filtration Unit Charcoal

Sampling

2/14/2018

WO-52716248

HVC B - Control Room Emergency Filtration Unit In-Place

Charcoal Testing

2/14/2018

WO-52728264

SBV A - Shield Building Ventilation Unit Charcoal Sampling

06/04/2018

WO-52767953

CVAS A - Controlled Ventilation Areas Filtration Unit In-

Place Charcoal Testing

01/11/2019

WO-52795776

HVC A - Control Room Emergency Filtration Unit In-Place

Charcoal Testing

07/09/2019

71124.07

Calibration

Records

ENV-FT-016

Flow Totalizer for APQ-1

03/13/2019

W/O 52817697

EM IM0110, Calibrate Backup Met Tower IAW MI-003-396

09/19/2019

W/O 52835981

EM IM0100, Calibrate Primary Met Tower IAW MI-003-395

2/20/2018

W/O 52843683

EM IM0110, Calibrate Backup Met Tower MI-003-396

03/20/2019

W/O 52859453

EM IM0100, Calibrate Primary Met Tower IAW MI-003-395

07/05/2019

Corrective Action

Documents

CR-HQN-YYYY-

NNNNN

2017-01911; 2018-02412

CR-WF3-YYYY-

NNNNN

2017-09465; 2017-09810; 2018-00539; 2018-01625; 2018-

01749; 2018-02620; 2018-04363; 2018-05354; 2018-06463;

2018-07201; 2018-07297; 2019-02608; 2019-03611; 2019-

03804; 2019-04264; 2019-04329; 2019-04412; 2019-05720;

2019-05762; 2019-05882; 2019-06851

Miscellaneous

Ground Water Monitoring Plan

2/10/2014

2017

Annual Radioactive Effluent Release Report

2018

2017

Annual Radiological Environmental Operating Report

2018

2018

Annual Radioactive Effluent Release Report

2019

2018

Annual Radiological Environmental Operating Report

2019

CR-WF3-2019-

07315

CR with attached Inspections of Met Towers

09/19/2019

PR-PRHQN-

2018-00908

Procedure Revision Tracker associated with CR-HQN-2018-

2412 for EN-FAP-OM-012

11/06/2018

Primary

Guyed Tower Inspection Report

6/3/2019

Secondary

Guyed Tower Inspection Report

6/3/2019

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

WF3-CR-2017-

09001

Response to Contaminated Spills/Leaks

11/10/2017

WF3-CR-2018-

03420

Response to Contaminated Spills/Leaks

06/16/2018

Procedures

CE-001-004

Periodic Analysis Scheduling

318

CE-003-522

Meteorological Data Collection and Processing

CE-003-523

Meteorological Monitoring Program

EN-CY-108

Monitoring of Nonradioactive Systems

EN-CY-111

Radiological Ground Water Monitoring Program

EN-CY-130

Radiological Environmental Monitoring Program

EN-RP-113

Response to Contaminated Spills/Leaks

MI-003-395

Primary Meteorological Tower Instrument Calibration EM

IM0110

2

MI-003-396

Secondary Meteorological Tower Instrument Calibration EM

IM0110

UNT-005-014

Offsite Dose Calculation Manual

307

Self-Assessments

Teledyne Brown Engineering Knoxville Laboratory Internal

QA Audit 2018

11/13/2018

Internal Assessment - Stanford Dosimetry

01/29/2019

NUPIC Joint Utility Audit No. 24791

05/09/2019

LO-WLO-2019-

0016

Pre-NRC Assessment of Radiation Safety Inspection Criteria

08/07/2019

Work Orders

WO 488788

Primary Met Tower Reading Suspect

2/19/2017

WO 501576

Troubleshoot/Repair Secondary Met Tower

From WR 437511

08/22/2018

WO 523912

Troubleshoot/Repair BU Met Tower 33 ft. Wind Direction

CR-19-4329

05/01/2019

71124.08

Corrective Action

Documents

CR-HQN-YYYY-

NNNNN

2017-01400; 2017-01543

CR-WF3-YYYY-

NNNNN

2017-03321; 2017-07899; 2017-07903; 2019-4177

Procedures

EN-RW-105

Process Control Program

EN-RW-106

Integrated Transportation Security Plan

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Self-Assessments WLO-2019-

000015

Pre-Assessment of NRC IP71124.08

8/21/2019

Shipping Records 17-1009

Unitech ORSC: Blowdown Resin

4/20/17

17-1017

Unitech-ORSC: Wood waste

6/19/17

17-1018

Unitech-ORSC: Wood waste

7/28/17

18-1013

ESM: Scaffolding

18-1014

ESBS: Cask Liner with Resin and Sludge

5/24/18

18-3002

Radiation Instruments: GA

1/18/18

19-1015

ESBC: Resin in a Shielded Cask

19-1019

ESBC: Resin in a Shielded Cask

8/15/19

71151

Miscellaneous

W3F1-2018-0066

NRC Performance Indicator (PI) Data - 3rd Quarter 2018

ROP Data

10/21/2018

W3F1-2019-0003

NRC Performance Indicator (PI) Data - 4th Quarter 2018

ROP Data

01/10/2019

W3F1-2019-0030

NRC Performance Indicator (PI) Data - 1st Quarter ROP

Data

04/11/2019

W3F1-2019-0053

NRC Performance Indicator (PI) Data - 2nd Quarter ROP

Data

07/15/2019

71152

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

2019-03572, 2019-04410, 2019-04628, 2019-04654,

2019-04988, 2019-05014, 2019-05026, 2019-05279,

2019-05488, 2019-05489, 2019-05662, 2019-05729,

2019-06000, 2019-07075, 2019-07529

Procedures

EN-OP-104

Operability Determination Process

OP-004-004

Control Element Drive

24