Submits Followup Response to NRC Bulletin 88-008, Thermal Stresses in Piping Connected to Rcs. Results of Reanalysis Determined That Auxiliary Spray Piping Not Subj to Combined Cyclic & Static Thermal & Other Stresses
ML18054A913
Person / Time
Site: Palisades Entergy icon.png
Issue date: 08/11/1989
From: Berry K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-88-008, IEB-88-8, TAC-69663, NUDOCS 8908180165
Download: ML18054A913 (3)


Text

consumers Power Kenneth W Berry

.PllWERINli Direcror Nuclear Licensing llllClllliAN"S PIUlliRESS General Offices: 1945 West Parnell-Road. Jackson, Ml 49201 * (517) 788-1636 August 11, 1989 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

FOLLOW-UP RESPONSE TO NRC BULLETIN 88 THERMAL STRESSES IN PIPING CONNECTED TO REACTOR COOLANT SYSTEMS (TAC NO 69663)

By letter dated September 19; 1988, Consumers Power Company provided the required initial response to the subject Bulletin. In our response we in-fbrmed the NRC of the completion of requested action 1 and provided our plan and schedule for the completion of requested actions 2 and 3. As required by the Bulletin, this submittal confirms the completion of requested actions 2 and 3 and describes the actions taken.

In our initial response we identified a section of the pressurizer auxiliary

  • spray piping as potentially being susceptible to the concerns of the Bulletin.

As previously committed we have performed ultrasonic and dye penetrant testing of the piping. The examinat.ions did not reveal any rejectable .indications.

We have also completed an analysis of the piping to determine if it could be subject to combined cyclic and static stresses that could cause fatigue failure during the remaining life of the Palisades Plant. ~

The analysis concluded that no fatigue failure concern exists'for at least 30 years. Given this conclusion, the auxiliary spray pipinfis not subject to combined cyclic and static thermal and other stress which c , ld cause fatigue failure during the remaining life of the plant. Consequently no further plans are proposed to implement additional programs to assure int~grity of the reactor coolant pressure boundary other than the Inservice Inspection Program presently in place. Periodic NDE of the auxiliary spray piping has been added to the program to be performed on a five year frequency.

As a result of NRC issuance of supplement 3 to the Bulletin, the applications for which split disc gate valves are used at Palisades were reviewed. This review determined there are no split disc gate valves contained in unisolable sections of piping from the reactor coolant pressure boundary that could subject the piping to thermal stratification as discussed in the supplement.

8908180165 890811 PDR ADOCK 05000255 Q PNU OC0889-0165-NL04 I \

  • 2 With this submittal, Consumers Power Company considers all actions necessary to fully address the concerns of the Bulletin to be completed. No further actions are planned.

Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades OC0889-0165-NL04

CONSUMERS POWER COMPANY Palisades Plant Docket 50-255 - License DPR-20 FOLLOW-UP RESPONSE TO NRC BULLETIN 88-08 At the request of the Commission and pursuant to the Atomic Energy Act of 1954 and the Energy Reorganization Act of 1974, as amended, and the Commission's Rules and Regulations thereunder, Consumers Power Company submits our follow-up response to NRC Bulletin 88-08 d-ated June 22, 1988, entitled, "Thermal Stresses in Piping Connected to Reactor Coolant Systems." Consumers Power Company's response is dated August 11, '1989.