consumers

.Power POW ERi Nii MICHlliAN'S PROliRESS Palisades Nuclear Plant:

27780 Blue Star Memorial Highway, Coven, Ml 49043 August 21, 1990 Nucl_ear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES ~LANT -

GB Slade General Manager TECHNICAL SPECIFICATIONS CHANGE REQUEST - PCS SURVEILLANCE REQUIREMENTS Enclosed is a request for change to the Palisades Technical Specifications regarding primary coolant system (PCS) inservice inspection requirements.

This change request will remove redundant requirements and change basis statements that are no longer applicable.

The current Technical Specifications con.tain specific hydrostatic and leak test and non-destructive testing requirements that are no longer necessary due to the requirements added to Section 4.0.5 of the Palisades Technical Specifications by Amendment 130.

Section 4.0.5 of the Technical Specifications requires inservice inspection of ASME Code Class 1, 2, and 3 components to be conducted in accordance with Section XI of the ASME Boiler and Pressure Vessel Code as required by 10CFR50.55a.

The proposed deletions are ASME Code Section XI required inspections and tests which are also required by Technical Specification 4.0.5.

Basis statements pertaining to the original steam generators tube plugging criteria are also requested to be removed.

These changes are consistent with the Standard Technical Specifications and the Technical Specifications Improvement Project efforts to develop restructured Technical Specifications.

/

Consumers Power Company requests that this Technical Specification change be approved prior to conducting the primary coolant and secondary hydrostatic and OC0890-0390-NL02 A CMS' ENERGY COMPANY

.(

e

' Nuclear Regulatory Commission Palisades Plant TSCR PCS Surv Requirements August 21, 1990 leak tests at the end of the upcoming refueling outage and the effective date of the change be upon issuance of the Amendment.

~_J~

Gerald B Slade General Manager CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades Attachment OC0890-0390-NL02

\\