Category:CORRESPONDENCE-LETTERS
MONTHYEARML17241A5001999-10-21021 October 1999 Forwards Rev 3 to Emergency Response Data Sys (ERDS) Data Point Library for St Lucie Unit 1.Rev Provides Replacement Pages & Follows Format Recommended by NUREG 1394, ERDS Implementation, Rev 1,App C ML17309A9981999-10-19019 October 1999 Forwards Revised Epips,Including Rev 3 to EPIP-10 & Rev 25 to HP-202.EPIP-10 Added Onsite Monitoring Points,Made Administrative Changes & Incorporated New Attachments & HP-202 Added Red Team Survey Points ML20217F6171999-10-0808 October 1999 Forwards Insp Repts 50-335/99-11 & 50-389/99-11 on 990827 & 990907-09.No Violations Identified.Matl Encl Contained Safeguards Info as Defined by 10CFR73.21 & Disclosed to Unauthorized Individuals Prohibited by Section 147 of AEA ML17241A4811999-10-0101 October 1999 Reports Number of Tubes Plugged During Unit 1 Refueling Outage SL1-16,per TS 4.4.5.5.a ML20212M1601999-09-28028 September 1999 Refers to 990908 Engineering Meeting Conducted at NRC Region II to Discuss Engineering Issues at Lucie & Turkey Point Facilities.List of Attendees & Copy of Presentation Handout Encl ML17241A4701999-09-25025 September 1999 Forwards Info Requested by NRC Staff During 990916 Telcon to Complete Staff Review of Request for risk-informed Extension of Action Completion/Aot Specified for Inoperable Train of LPSI Sys at Plant ML17241A4721999-09-24024 September 1999 Forwards Rev 1 to Plant Change/Mod (PCM) 99016 to St Lucie Unit 1,Cycle 16 COLR, IAW TS 6.9.1.11.d.Refueling Overhaul Activities Are Currently in Progress & Reactor Operations for Cycle 16 Are Scheduled to Commence in Oct 1999 ML17241A4681999-09-22022 September 1999 Requests Restriction Be Added to Senior Operator License SOP-21093 for TE Bolander.Nrc Forms 369,encl.Encl Withheld Per 10CFR2.790(a)(6) ML17241A4671999-09-20020 September 1999 Forwards Completed NRC Form 536, Operator Licensing Exam Data, for St Lucie Units 1 & 2,as Requested in Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams. ML17241A4581999-09-13013 September 1999 Forwards Info Requested by NRC Staff During 990630 & 0816 Telcons,To Complete Review of Proposed License Amend for Fuel Reload Process Improvement Program ML17241A4531999-08-31031 August 1999 Informs That No Candidates from St Lucie Plant Will Be Participating in PWR Gfes Being Administered on 991006 ML17241A4521999-08-31031 August 1999 Withdraws Relief Request 16 & Suppl Relief Request 15 with Info Requested During 990526 Telephone Conference Re ISI Insp Plan,Third 10-yr Interval ML17241A4501999-08-26026 August 1999 Informs That FPL Has Reviewed Reactor Vessel Integrity Database,Called RVID2,re Closure of GL 92-01,rev 1,suppl 1. Requested Corrections & Marked Up Pages from Rvid 2 Database Summary Repts That Correspond to Comments,Attached ML17241A4371999-08-13013 August 1999 Forwards fitness-for-duty Program Performance Data for six- Month Period Ending 990630,per 10CFR26.71(d) ML17241A4461999-08-11011 August 1999 Requests That W Rept Entitled, Evaluation of Turbine Missile Ejection Probability Resulting from Extending Test Interval of Interceptor & Reheat Stop Valves at St Lucie Units 1 & 2, Be Withheld from Public Disclosure L-99-171, Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3)1999-07-29029 July 1999 Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3) ML17309A9911999-07-26026 July 1999 Forwards Revised EPIPs & Revised Procedures That Implement Emergency Plan as Listed.Procedures Provides Instruction for Operational Support Ctr (OSC) Chemistry Supervisor to Establish Remote Labs at Locations Specified ML17241A4471999-07-22022 July 1999 Requests That Rev 1 to WCAP-14732 & Rev 1,Add 1 to WCAP-14732 Be Withheld from Public Disclosure ML17241A4221999-07-22022 July 1999 Forwards List of Proposed Licensing Actions for St Lucie Units 1 & 2,planned During Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates. ML17241A4151999-07-22022 July 1999 Forwards Revised Relief Request 25 for Second 10-yr ISI Interval for Unit 2 ML17241A4101999-07-16016 July 1999 Forwards FP&L Supplemental Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants ML17309A9881999-07-0707 July 1999 Forwards Rev 5 to EPIP-03, Emergency Response Organization Notification/Staff Augmentation. Rev 5 to EPIP-03 Was Revised to Transfer EP Responsibilities from Training Manager to Protection Svcs Manager ML20209F1541999-07-0606 July 1999 Informs That NRC in Process of Conducting Operational Safeguards Response Evaluations at Nuclear Power Reactors. Plant Chosen for Such Review Scheduled for Wk of 990823-26 ML17241A4011999-06-30030 June 1999 Forwards Info Copy of Florida Wastewater Permit (FL0002208) (Formerly NPDES Permit) Mod,Which Was Issued by Florida Dept of Environ Protection on 990604 ML17241A3971999-06-30030 June 1999 Forwards Suppl Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Movs, as Requested in 990317 Ltr ML17355A3661999-06-30030 June 1999 Forwards Florida Power & Light Topical QA Rept, Dtd June 1999.Encl I Includes Summary of Changes Made to Topical QA Rept Since 1998 ML17241A3951999-06-29029 June 1999 Provides Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants.Gl 98-01, Y2K Readiness of Computer Sys at Nuclear Power Plants, Requested Response on Status of Facility Y2K Readiness by 990701.Disclosure Encl ML17241A3731999-06-17017 June 1999 Supplements Relief Requests 4,11 & 13 for Third ten-year ISI Interval with Info Requested During 990526 Telcon.Expedited Review Is Requested by 990730 to Avoid Negatively Impacting Upcoming St Lucie Unit 1 Refueling Outage (SL1-16) ML17241A3641999-06-14014 June 1999 Submits Supplement to Relief Request 24 with Info Requested by Nrc.In Addition Relief Request 24 Is Identical to St Lucie Unit 1 Relief Request 4 for Third ISI Interval Being Supplemented by FPL Ltr L-99-139 ML20195F3871999-06-11011 June 1999 Final Response to FOIA Request for Documents.App a Records Being Withheld in Entirety (Ref FOIA Exemption 5) IA-99-247, Final Response to FOIA Request for Documents.App a Records Being Withheld in Entirety (Ref FOIA Exemption 5)1999-06-11011 June 1999 Final Response to FOIA Request for Documents.App a Records Being Withheld in Entirety (Ref FOIA Exemption 5) L-99-129, Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3)1999-06-0909 June 1999 Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3) ML17241A3561999-06-0707 June 1999 Forwards Rept Containing Brief Description & Summary of SEs for Changes,Tests & Experiments Which Were Approved for Unit 3 During Period of 970526-981209 ML17241A3601999-06-0707 June 1999 Forwards Correction to Annual Radiological Environ Operating Rept for CY98.Util Has Identified Transcription Error on Last Page of Attachment C of Rept,Results from Interlaboratory Comparison Program 1998 ML20195F3941999-05-27027 May 1999 FOIA Request That Memo from J Calvo to Fl Lebdon Re TIA - St Lucie,Unit 1 Environ Qualification of Woodward Governor Controls Be Placed in PDR ML17241A3461999-05-24024 May 1999 Forwards Revised Relief Request 22 to Clarify Several Areas of Relief.Nrc Action Is Requested to Be Complete by Aug 1999 to Support Planning for Spring 2000 Unit 2 Refueling Outage ML17241A3391999-05-20020 May 1999 Forwards Notification of Change to Small Break LOCA ECCS Evaluation Model Used for St Lucie Unit 1.Anomaly Was Discovered & Corrected That Resulted in Reducing Calculated PCT for Limiting SBLOCA by More than 50 F ML17241A3371999-05-20020 May 1999 Forwards Util Suppl to GL 95-07 Response Re pressure-locking & Thermal Binding of safety-related power-operated Gate Valves,In Response to NRC Second RAI Dtd 990225 ML20207C7531999-05-17017 May 1999 Discusses Issue Identified by FPL in Feb 1998 Involving Potential for Fire to Cause Breach of Rc Sys High/Low Pressure Interface Boundary & NRC Decision for Exercise of Enforcement Discretion ML17241A3301999-05-17017 May 1999 Forwards LER 99-004-00 Re as Found Cycle 10 Psv Setpoints Outside TS Limits,Which Occurred on 990415.Root Cause Determination Not Yet Complete.Suppl to Include Root Cause & Corrective Actions Will Be Submitted ML17309A9821999-05-10010 May 1999 Forwards Rev 36 to St Lucie Emergency Plan, Per 10CFR50.54(q).Executive Summary & Summary of Changes Incorporated by Rev,Encl IR 05000335/19980141999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated ML17241A3221999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated ML17229B1071999-04-28028 April 1999 Forwards 1998 Annual Environ Operating Rept for St Lucie Unit 2. Rept Includes Discussions of 5-inch Barrier Net Maint & Taprogge Condenser Tube Cleaning Sys Ball Loss,As Agreed at First Biennial Sea Turtle Meeting Held on 980120 ML17229B1051999-04-22022 April 1999 Requests That Listed Individuals Be Placed on Official Serve List for Nuclear Matl Safety & Safeguards Info Notices ML17229B1061999-04-21021 April 1999 Notifies NRC of Change in Medical Status of Licensed Operator Pf Farnsworth (Docket 55-21285,license SOP-21094). NRC Form 3996, Medical Exam Certification, Encl.Encl Withheld Per 10CFR2.790(a)(6) ML17309A9851999-04-15015 April 1999 Requests That NRC Review Denial of Appeal from Assessment of Fees Assessed in 981101 Invoice RS0062-99 & Assessment of Fees in Invoice RS0182-99 Which Was Also Denied in 990305 Ltr.Both Invoices Are for Fees Re Inspector GG Warnick ML20205M0431999-04-13013 April 1999 Eighth Partial Response to FOIA Request for Records.App Q & R Records Encl & Being Made Available in PDR ML17229B0951999-04-0808 April 1999 Requests Approval of Encl Revised Relief Request 6,in Response to 990322 Telcon with NRC & 10CFR55.55a(a)(3). Request States That Visual VT-3 Exams Will Be Conducted IAW IWA-2213 & Repairs Will Be IAW Util ASME Section IX Program ML17229B0821999-04-0707 April 1999 Requests Approval of Interim Relief Request 26 Re Repair Requirements for Class 2 ECCS Piping,Per 10CFR50.55a(a)(3) & 50.55a(g)(iii).Alternative Actions Apply Guidance of GLs 91-18 & 90-05 & ASME Code Case N-513.Evaluation,encl 1999-09-28
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML17241A5001999-10-21021 October 1999 Forwards Rev 3 to Emergency Response Data Sys (ERDS) Data Point Library for St Lucie Unit 1.Rev Provides Replacement Pages & Follows Format Recommended by NUREG 1394, ERDS Implementation, Rev 1,App C ML17309A9981999-10-19019 October 1999 Forwards Revised Epips,Including Rev 3 to EPIP-10 & Rev 25 to HP-202.EPIP-10 Added Onsite Monitoring Points,Made Administrative Changes & Incorporated New Attachments & HP-202 Added Red Team Survey Points ML17241A4811999-10-0101 October 1999 Reports Number of Tubes Plugged During Unit 1 Refueling Outage SL1-16,per TS 4.4.5.5.a ML17241A4701999-09-25025 September 1999 Forwards Info Requested by NRC Staff During 990916 Telcon to Complete Staff Review of Request for risk-informed Extension of Action Completion/Aot Specified for Inoperable Train of LPSI Sys at Plant ML17241A4721999-09-24024 September 1999 Forwards Rev 1 to Plant Change/Mod (PCM) 99016 to St Lucie Unit 1,Cycle 16 COLR, IAW TS 6.9.1.11.d.Refueling Overhaul Activities Are Currently in Progress & Reactor Operations for Cycle 16 Are Scheduled to Commence in Oct 1999 ML17241A4681999-09-22022 September 1999 Requests Restriction Be Added to Senior Operator License SOP-21093 for TE Bolander.Nrc Forms 369,encl.Encl Withheld Per 10CFR2.790(a)(6) ML17241A4671999-09-20020 September 1999 Forwards Completed NRC Form 536, Operator Licensing Exam Data, for St Lucie Units 1 & 2,as Requested in Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams. ML17241A4581999-09-13013 September 1999 Forwards Info Requested by NRC Staff During 990630 & 0816 Telcons,To Complete Review of Proposed License Amend for Fuel Reload Process Improvement Program ML17241A4531999-08-31031 August 1999 Informs That No Candidates from St Lucie Plant Will Be Participating in PWR Gfes Being Administered on 991006 ML17241A4521999-08-31031 August 1999 Withdraws Relief Request 16 & Suppl Relief Request 15 with Info Requested During 990526 Telephone Conference Re ISI Insp Plan,Third 10-yr Interval ML17241A4501999-08-26026 August 1999 Informs That FPL Has Reviewed Reactor Vessel Integrity Database,Called RVID2,re Closure of GL 92-01,rev 1,suppl 1. Requested Corrections & Marked Up Pages from Rvid 2 Database Summary Repts That Correspond to Comments,Attached ML17241A4371999-08-13013 August 1999 Forwards fitness-for-duty Program Performance Data for six- Month Period Ending 990630,per 10CFR26.71(d) ML17241A4461999-08-11011 August 1999 Requests That W Rept Entitled, Evaluation of Turbine Missile Ejection Probability Resulting from Extending Test Interval of Interceptor & Reheat Stop Valves at St Lucie Units 1 & 2, Be Withheld from Public Disclosure L-99-171, Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3)1999-07-29029 July 1999 Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3) ML17309A9911999-07-26026 July 1999 Forwards Revised EPIPs & Revised Procedures That Implement Emergency Plan as Listed.Procedures Provides Instruction for Operational Support Ctr (OSC) Chemistry Supervisor to Establish Remote Labs at Locations Specified ML17241A4221999-07-22022 July 1999 Forwards List of Proposed Licensing Actions for St Lucie Units 1 & 2,planned During Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates. ML17241A4471999-07-22022 July 1999 Requests That Rev 1 to WCAP-14732 & Rev 1,Add 1 to WCAP-14732 Be Withheld from Public Disclosure ML17241A4151999-07-22022 July 1999 Forwards Revised Relief Request 25 for Second 10-yr ISI Interval for Unit 2 ML17241A4101999-07-16016 July 1999 Forwards FP&L Supplemental Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants ML17309A9881999-07-0707 July 1999 Forwards Rev 5 to EPIP-03, Emergency Response Organization Notification/Staff Augmentation. Rev 5 to EPIP-03 Was Revised to Transfer EP Responsibilities from Training Manager to Protection Svcs Manager ML17241A4011999-06-30030 June 1999 Forwards Info Copy of Florida Wastewater Permit (FL0002208) (Formerly NPDES Permit) Mod,Which Was Issued by Florida Dept of Environ Protection on 990604 ML17241A3971999-06-30030 June 1999 Forwards Suppl Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Movs, as Requested in 990317 Ltr ML17355A3661999-06-30030 June 1999 Forwards Florida Power & Light Topical QA Rept, Dtd June 1999.Encl I Includes Summary of Changes Made to Topical QA Rept Since 1998 ML17241A3951999-06-29029 June 1999 Provides Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants.Gl 98-01, Y2K Readiness of Computer Sys at Nuclear Power Plants, Requested Response on Status of Facility Y2K Readiness by 990701.Disclosure Encl ML17241A3731999-06-17017 June 1999 Supplements Relief Requests 4,11 & 13 for Third ten-year ISI Interval with Info Requested During 990526 Telcon.Expedited Review Is Requested by 990730 to Avoid Negatively Impacting Upcoming St Lucie Unit 1 Refueling Outage (SL1-16) ML17241A3641999-06-14014 June 1999 Submits Supplement to Relief Request 24 with Info Requested by Nrc.In Addition Relief Request 24 Is Identical to St Lucie Unit 1 Relief Request 4 for Third ISI Interval Being Supplemented by FPL Ltr L-99-139 L-99-129, Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3)1999-06-0909 June 1999 Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3) ML17241A3601999-06-0707 June 1999 Forwards Correction to Annual Radiological Environ Operating Rept for CY98.Util Has Identified Transcription Error on Last Page of Attachment C of Rept,Results from Interlaboratory Comparison Program 1998 ML17241A3561999-06-0707 June 1999 Forwards Rept Containing Brief Description & Summary of SEs for Changes,Tests & Experiments Which Were Approved for Unit 3 During Period of 970526-981209 ML20195F3941999-05-27027 May 1999 FOIA Request That Memo from J Calvo to Fl Lebdon Re TIA - St Lucie,Unit 1 Environ Qualification of Woodward Governor Controls Be Placed in PDR ML17241A3461999-05-24024 May 1999 Forwards Revised Relief Request 22 to Clarify Several Areas of Relief.Nrc Action Is Requested to Be Complete by Aug 1999 to Support Planning for Spring 2000 Unit 2 Refueling Outage ML17241A3371999-05-20020 May 1999 Forwards Util Suppl to GL 95-07 Response Re pressure-locking & Thermal Binding of safety-related power-operated Gate Valves,In Response to NRC Second RAI Dtd 990225 ML17241A3391999-05-20020 May 1999 Forwards Notification of Change to Small Break LOCA ECCS Evaluation Model Used for St Lucie Unit 1.Anomaly Was Discovered & Corrected That Resulted in Reducing Calculated PCT for Limiting SBLOCA by More than 50 F ML17241A3301999-05-17017 May 1999 Forwards LER 99-004-00 Re as Found Cycle 10 Psv Setpoints Outside TS Limits,Which Occurred on 990415.Root Cause Determination Not Yet Complete.Suppl to Include Root Cause & Corrective Actions Will Be Submitted ML17309A9821999-05-10010 May 1999 Forwards Rev 36 to St Lucie Emergency Plan, Per 10CFR50.54(q).Executive Summary & Summary of Changes Incorporated by Rev,Encl ML17241A3221999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated IR 05000335/19980141999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated ML17229B1071999-04-28028 April 1999 Forwards 1998 Annual Environ Operating Rept for St Lucie Unit 2. Rept Includes Discussions of 5-inch Barrier Net Maint & Taprogge Condenser Tube Cleaning Sys Ball Loss,As Agreed at First Biennial Sea Turtle Meeting Held on 980120 ML17229B1051999-04-22022 April 1999 Requests That Listed Individuals Be Placed on Official Serve List for Nuclear Matl Safety & Safeguards Info Notices ML17229B1061999-04-21021 April 1999 Notifies NRC of Change in Medical Status of Licensed Operator Pf Farnsworth (Docket 55-21285,license SOP-21094). NRC Form 3996, Medical Exam Certification, Encl.Encl Withheld Per 10CFR2.790(a)(6) ML17309A9851999-04-15015 April 1999 Requests That NRC Review Denial of Appeal from Assessment of Fees Assessed in 981101 Invoice RS0062-99 & Assessment of Fees in Invoice RS0182-99 Which Was Also Denied in 990305 Ltr.Both Invoices Are for Fees Re Inspector GG Warnick ML17229B0951999-04-0808 April 1999 Requests Approval of Encl Revised Relief Request 6,in Response to 990322 Telcon with NRC & 10CFR55.55a(a)(3). Request States That Visual VT-3 Exams Will Be Conducted IAW IWA-2213 & Repairs Will Be IAW Util ASME Section IX Program ML17229B0821999-04-0707 April 1999 Requests Approval of Interim Relief Request 26 Re Repair Requirements for Class 2 ECCS Piping,Per 10CFR50.55a(a)(3) & 50.55a(g)(iii).Alternative Actions Apply Guidance of GLs 91-18 & 90-05 & ASME Code Case N-513.Evaluation,encl ML17229B0851999-04-0505 April 1999 Requests Approval of Encl Relief Request 25 Which Proposes to Use Alternative Requirements of ASME Code Case N-613 in Lieu of Requirements of ASME Section XI Figures IWB-2500-7(a) & IWB-2500-7(b).Action Requested by Aug 1999 ML17309A9791999-03-31031 March 1999 Forwards Revised EPIPs Including Rev 2 to EPIP-00,rev 2 to EPIP-09,rev 2 to EPIP-10 & Rev 10 to HP-207.Summary of Revs Listed ML17309A9761999-03-23023 March 1999 Forwards Revised Epips,Including Rev 4 to EPIP-03, Er Organization Notification/Staff Augmentation, Rev 3 to EPIP-05, Activation & Operation of OSC & Rev 14 to HP-200, HP Emergency Organization. Changes to Epips,Discussed ML17229B0691999-03-19019 March 1999 Transmits TS Pages Requested by NRC for Use in Issuance of Proposed License Amend Re SFP Storage Capacity,Per Soluble Boron Credit ML17229B0721999-03-16016 March 1999 Requests Approval of Enclosed Relief Requests 23 & 24 Re ISI Plan for Second ten-year Interval.Nrc Action Is Requested to Be Complete by Aug 1999 to Support Planning for Spring 2000 Unit 2 Refueling Outage ML17355A2631999-03-12012 March 1999 Forwards FPL Decommissioning Fund Status Repts for St Lucie, Units 1 & 2 & Turkey Point,Units 3 & 4.Rept for St Lucie, Unit 2 Provides Status of Decommissioning Funds for All Three Owners of That Unit ML17229B0481999-03-10010 March 1999 Informs That Util Delivered Matls Requested in Encl 1 of NRC Ltr by Hand on 990308,as Requested by NRC Ltr Dtd 990218 1999-09-25
[Table view] Category:UTILITY TO NRC
MONTHYEARML17223A9401990-09-13013 September 1990 Forwards Evaluation of Potential Safety Impact of Failed Control Element Assemblies on Limiting Transients for Facility ML17223A9341990-09-10010 September 1990 Forwards Addl Info Re Generic Implications & Resolution of Control Element Assembly (CEA) Failure at Facility,Per NRC Request.Description of Testing Program for Old Style CEAs in Unit 1 Core Encl L-90-315, Advises That Util Has Completed Evaluation of NUREG-0737, Item II.D.1,SER Item 81990-08-30030 August 1990 Advises That Util Has Completed Evaluation of NUREG-0737, Item II.D.1,SER Item 8 ML17223A9201990-08-28028 August 1990 Forwards Forms NIS-1 & NIS-2, Owners Rept for Inservice Insps as Required by Provisions of ASME Code Rules, Per 900725 Ltr ML17223A8911990-08-20020 August 1990 Forwards Corrected Monthly Operating Repts for Jul 1990 for St Lucie Units 1 & 2 & Summary of Operating Experience ML17348A5041990-08-17017 August 1990 Forwards fitness-for-duty Program Performance Data for Jan-June 1990 L-90-301, Discusses Generic Implications & Resolution of Control Element Assemblies Failure at Plant1990-08-16016 August 1990 Discusses Generic Implications & Resolution of Control Element Assemblies Failure at Plant ML17223A8751990-08-0909 August 1990 Responds to Violations Noted in Insp Rept 50-335/90-14. Corrective Actions:Rcs Flow Determination by Calorimetric Procedure Repeated W/Supervisor of Individual Observing & Individual Counseled by Supervisor IR 05000335/19900141990-08-0909 August 1990 Responds to Violations Noted in Insp Rept 50-335/90-14. Corrective Actions:Rcs Flow Determination by Calorimetric Procedure Repeated W/Supervisor of Individual Observing & Individual Counseled by Supervisor ML17348A4701990-07-27027 July 1990 Forwards Rept Detailing Investigative Analysis of Unsatisfactory Blind Specimen Results,Identification of Causes & Corrective Actions Taken by Lab to Prevent Recurrence,Per Unsatisfactory Performance Testing ML17223A8621990-07-25025 July 1990 Advises That NIS-1 & NIS-2 Forms,As Part of Inservice Insp Rept,Will Be Submitted by 900831 ML17348A4281990-07-25025 July 1990 Forwards Decommissioning Financial Assurance Repts for Plants,Per 10CFR50.33(k) & 50.75(b) ML17223A8631990-07-25025 July 1990 Submits Addl Info Re Implementation of Programmed Enhancements Per Generic Ltr 88-17, Loss of Dhr. All Mods for Unit 1 Completed & Operational.Mods for Unit 2 Schedule for Upcoming Refueling Outage L-90-271, Responds to NRC Ltr Re Violations Noted in Insp Repts 50-335/90-09 & 50-389/90-09.Corrective Actions:Procedural Expectation Re Hanging & Removal of Deficiency Tags Will Be Reemphasized to Personnel Generating Work Orders1990-07-20020 July 1990 Responds to NRC Ltr Re Violations Noted in Insp Repts 50-335/90-09 & 50-389/90-09.Corrective Actions:Procedural Expectation Re Hanging & Removal of Deficiency Tags Will Be Reemphasized to Personnel Generating Work Orders ML17223A8581990-07-19019 July 1990 Forwards Implementation Status of 10CFR50.62 Mod at Facility Re Requirements for Reduction of Risk from ATWS Events for Light Water Cooled Nuclear Power Plants ML17223A8491990-07-18018 July 1990 Responds to NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg by Rosemount. No Rosemount Transmitters Models 1153 Series B,1153 Series D & 1154 Mfg Prior to 890711 Supplied by Different Vendor ML17223A8521990-07-17017 July 1990 Forwards Addl Info Requested Re Generic Implications & Resolution of Control Element Assembly Failure at Plant.Encl Confirms Util Intent to Follow C-E Regulatory Response Group Action Program IR 05000335/19900131990-07-0909 July 1990 Responds to Violations Noted in Insp Repts 50-335/90-13 & 50-389/90-13.Corrective Actions:Maint Personnel Counseled & Aware of Importance of Verifying Design Configuration Requirements ML17223A8421990-07-0909 July 1990 Responds to Violations Noted in Insp Repts 50-335/90-13 & 50-389/90-13.Corrective Actions:Maint Personnel Counseled & Aware of Importance of Verifying Design Configuration Requirements ML17348A3881990-07-0505 July 1990 Requests Audit of NRC Records to Independently Verify Reasonableness of Charges Assessed Against Util,Per 10CFR170 Svcs ML17223A8391990-07-0303 July 1990 Forwards Results of Beach Survey Procedure & Reduction of Field Survey Data,Per Tech Spec 4.7.6.1.1.Unit 1 Updated Fsar,Section 2.4.2.2,concluded That Dune Condition Acceptable Per Tech Spec 5.1.3 ML17223A8381990-07-0202 July 1990 Requests Termination of Operator License for s Lavelle.Util Also Requests That Ltr Be Withheld (Ref 10CFR2.790) L-90-239, Forwards Rev 6 to Guard Training & Qualification Plan.Rev Withheld (Ref 10CFR73.21)1990-07-0202 July 1990 Forwards Rev 6 to Guard Training & Qualification Plan.Rev Withheld (Ref 10CFR73.21) ML17223A8371990-06-27027 June 1990 Provides Details of Implementation Plan Re Recommendations & Schedular Requirements in Generic Ltr 89-10,per 891228 Ltr.Design Basis Review of safety-related motor-operated Valves & Determination of Switch Settings in Progress ML17308A4981990-06-27027 June 1990 Responds to Generic Ltr 90-04 Re Request for Info on Status of Licensee Implementation of Generic Safety Issues Resolved W/Imposition of Requirements or Corrective Actions ML17223A8341990-06-19019 June 1990 Forwards Corrected Proposed Tech Spec Figure 3.4-2 Per 900207 Application for Amend to License NPF-16,incorporating Revised Pressure/Temp Limits & Results of Revised Low Temp Overpressure Protection Analysis Into Tech Specs ML17223A8241990-06-18018 June 1990 Forwards Revised Combined Semiannual Radioactive Effluent Release Rept for Jan-June 1988. ML17223A8271990-06-18018 June 1990 Forwards Ma Smith 900601 Ltr to WR Cunningham of EPA Requesting Mod to Plant NPDES Permit to Permit Cleaning of Facility & to Establish Discharge Limits for Chemical Cleaning Wastes ML17348A2981990-06-12012 June 1990 Forwards Rev 16 to Topical QA Rept. ML17223A6761990-05-31031 May 1990 Advises That Air Operated safety-related Components Will Perform All Design Basis Events,Per 881227 Ltr.All Actions Required by Generic Ltr 88-14 Complete for Plant ML17348A2651990-05-29029 May 1990 Submits Rept Detailing Investigative Analysis of Unsatisfactory Blind Specimen Results,Identification of Causes & Corrective Actions Taken by Lab to Prevent Recurrence,Per 10CFR26,App A.2.8(e)(4) ML17223A6741990-05-22022 May 1990 Forwards Info Re Status of 10CFR50.62 Mods to Meet ATWS Requirements as of 900515.Plant Change/Mod Package Necessary for Installing ATWS Will Be Issued by 900630.Hardware Procurement for Diverse Scram Sys Approx 90% Complete ML17223A6361990-05-0808 May 1990 Forwards Final Response to NRC Bulletin 88-010, Nonconforming Molded-Case Circuit Breakers. One Untraceable Circuit Breaker Installed in Unit 2 Qualified SPDS & Replaced W/Traceable Breaker ML17223A6281990-04-21021 April 1990 Forwards St Lucie Unit 2 Annual Environ Operating Rept, Vol 1 1989. ML17223A6081990-04-13013 April 1990 Responds to Violations Noted in Insp Repts 50-335/90-02 & 50-389/90-02.Corrective Actions:Nuclear Plant Supervisor Required to Remain in Control Room During Significant Changes in Power Operation & Preventive Maint Upgraded ML17223A6071990-04-0505 April 1990 Responds to NRC Bulletin 89-001, Failure of Westinghouse Steam Generator Tube Mechanical Plugs. Removal & Replacement of Cold Leg Side Plugs of Heat Number 3513 for Unit 1 Completed During Refueling Outage ML17308A4911990-04-0202 April 1990 Forwards Description & Summary of Safety Evaluations of Plant Changes/Mods Reportable Per 10CFR50.59.Repair &/Or Replacement of Protective Coatings on Surfaces Inside Bldg Pose No Unreviewed Safety Question ML17223A5931990-03-30030 March 1990 Forwards Status of 10CFR50.62, Requirements for Reduction of Risk from ATWS Mods at Plant as of 900315.Diverse Scram Sys Module Prototype Fabrication in Progress ML17223A5921990-03-27027 March 1990 Forwards Addl Info on Proposed License Amend Re Increased Max Allowable Resistance Temp Detector Delay Time,Per 891219 Telcon & Advises That Util Request to Increase Plant Resistance Temp Detector Response Time Remain Unchanged ML17223A5831990-03-19019 March 1990 Forwards Response to Generic Ltr 89-19, Request for Action Re Resolution of USI A-47, 'Safety Implications of Control Sys in LWR Nuclear Power Plants,' Per 10CFR50.54(f) ML17347B6191990-03-13013 March 1990 Provides Listing of Property Insurance Programs ML17223A5531990-03-0909 March 1990 Submits Results of Investigation of Error Detected in Dose Assessment During 900124 NRC Evaluated Exercise at Plant. Operator Error Caused Keyboard Hangup Requiring Computer Restart ML17223A5451990-03-0808 March 1990 Forwards Revised Tech Specs Re Steam Generator Tube Repairs, Per 890602 Telcon & Subsequent Discussions W/Nrc ML17308A4871990-03-0707 March 1990 Forwards Response to Eight Audit Questions & Licensing Bases Criteria to Resolve Station Blackout Issue.Util Currently Has Procedures to Mitigate Effects of Hurricanes & Tornados Which Meet or Exceed NUMARC 87-00 Guidelines ML17347B5881990-03-0101 March 1990 Responds to Generic Ltr 90-01, Request for Voluntary Participation in NRC Regulatory Impact Survey. Info Covers Time Spent by Key Power Plant Managers in Responding to Operational Insps & Audits ML17347B6031990-02-27027 February 1990 Requests Approval to Use Code Case N-468 at Plants ML17223A5321990-02-26026 February 1990 Forwards CEN-396 (L)-NP, Verification of Acceptability of 1-Pin Burnup Limit of 60 Mwd/Kg for St Lucie Unit 2. ML20012A0011990-02-26026 February 1990 Notifies That Followup Actions Completed on Schedule & Incorporated Into Rev 25 to Plant Physical Security Plan,Per NRC 890605 Request ML17223A5411990-02-26026 February 1990 Provides Addl Info Re Proposed License Amends Re Moderator Temp Coefficient Surveillance Requirements,Per 891026 & 900109 Telcons IR 05000335/19890241990-02-22022 February 1990 Responds to Violations Noted in Insp Repts 50-335/89-24 & 50-389/89-24.Corrective Actions:Applicable Procedures Changed to Clarify Which Spaces & Blocks Required to Be Completed on Plant Work Order & QC Supervisor Counseled 1990-09-13
[Table view] |
Text
REQULATORY INFORNATION DISTRIBUTION SYSTEN (R IDB)
ACCESSION NBR: 860912001 1 DQC. DATE: 86/09/04 NOTARIZED: NQ 0 FACIL: 50-389 St. Lucie Planti Unit 2i Flov ida Pou)er 8c Light Co. 050003S9 AUTH. NAl'lE AUTHOR AFFILIATION WOODY'. O. Florida Potoer Zc Light Co.
REC IP I ENT AFF IL I ATI QN NOTES'OCKET RECIP. NANE TOURIQNY, E. Q. PWR Pv object Directov ate 8
SUBJECT:
Forwards v esponse to 860818 request for addi info v e pv oposed Tech Specs to incorporate revised pv'essuv e temp 8c lou temp overpressuv e pv otection limits fov RCS.
DISTR IBUTION CODE: A001D COPIES RECEIVED: LTR ENCL SIZE:
TITLE: QR Submittal: Qenev al Distv ibution RECIPIENT CQPIEB REC IP I ENT COP IEB ID CODE/NANE LTTR ENCL ID CODE/NAI'lE LTTR ENCL PWR-B EB 1 PWR-B PEICSB 2 2 PWR-B FOB 1 PWR-B PDS LA 0 PWR-B PDS PD Of 5 5 TOURIQNY> E 1 PWR-B PEICBB 1 1 PWR-B RSB 1 INTERNAL. ADN/LFllB 0 ELD S2 0 NRR/ORAB 0 L 04 1 RQN2 1 EXTERNAL: EQ5Q BRUSKE> 8 1 1 LPDR 03 NRC PDR 02 1 1 NBIC 05' TOTAL NUl'lBER OF COPIEB REQUIRED'TTR 22 ENCL 18
aP! 'i C>
('3(f, >'.
$ <)
uN
~...,.
., '>it3.i. U(,"'.'",7(*'TC l'la I'Ts'('iP<<l.ll (('<(>> I'8, ll(.">.,lH l'i l ("'Y,,
<~'<~ KHATQI~f '~OXPOXb8:3( (6 ..('.((< J.l<>( ',k(') ACE',HF',( (
-'EGQ'.~ (( .n.') g(l>>(. l 8 z~~(((g'4 (',b~zol"3 i(", q j'(~k'(((-I'( (~ ((( l 4U (.'UC -:~(I f" '..)T i <<"(g ll'i~>;"'( > ( l".'".
03 "k(" p + J >~ 'f')(((0 c (~(( f.'(-i ). .>> .:),(0 "',(,
l:(UI>(wl ";< "l (A =<<HAY(.'i(. a .'"
98'~" o4 "a'('('<l .l ( (l,((w'li'l i) .l pry~ ')" (ill ~
O ( (li' ll 46 1 "0 8 .~$ )<>:" Q k 3()&8 0 J'('! ((0 q '"i '~ TS(('76'3 I 3 J4 1'(l.~~("('q b98 LV9'( '386'TOcj'TOGA j: (( e',(.;( ) ]6 fl 1l ( O'H2((q()'Y(/
il'3>1 .(Q $ ~~ PR(((k x (ia l,'f QQ jD ("l ')'f(( (g!' f(l'T'(~'.) (l(il (0 J.'8 ".. 'Ã:3 ... ( .':QBVI3~3'3 ". 'I ",U;) 6,'.()( 5, .O'Q,) l(4'>> l(>>I);AT-.,k<<
rroif(.(die<<'! xU f~"( sna8;5;;,trim(lui! '.<> 'i.,l l
);>'i'~i
,'I(lflg J')(:- '" f) 1"Y(&; 11338
.HANK ~(~(Q> OT
('~l'!:)>'3l 8 RtJR J >N ',N'lYNY i., ') 'B3:)
-l((,'((<('~, l003
).3H (5,.'
l(H>
A l (-(G l G-R(.)R 3 YV(""ERl/aT L0 tl(l CG't G 6(""0 G"-RVg 3'l G- '",H(l
>'H('<:;".)>
'=!(~ )HXQJ3 V.~ 'if(<t;>
3JK=l 439 '
1lgg t l )llIl
'('))',()
I ~ "~(:>0~'(~ Q4',) ;., lANk,,i;,(;-
a,() ~l(l'l '>)lyj 4 ( l.i .~4 sw all. -l(l e,.( l""" 'I(l "-<<(ll,': /j f() "',',
O. BOX 14000, JUNO BEACH, FL 33408 e-
/five sAg FLORIDA POWER & LIGHT COMPANY SEP 4 1980 L-86-353 Office of Nuclear Reactor Regulation Attention: Mr. E. G. Tourigny, Project Manager PWR Project Directorate II8 Division of PWR Licensing - B U.S. Nuclear Regulatory Commission Washington, D.C. 20555
Dear Mr. Tourigny:
Re: St. Lucie Unit 2 Docket No. 50-389 Low Tem erature Over ressure Protection By letter L-86-281, dated July 15, 1986, Florida Power & Light Company submitted proposed Technical Specifications to incorporate revised pressure-temperature and low temperature overpressure protection limits for the reactor coolant system. On August 18, 1986 you issued a request for additional information pursuant to NRC staff review of our proposal. The information you requested is attached.
Please contact us if you have any questions about this submittal.
Very truly yours,
. O. ood Group Vic P esident Nuclear E rgy COW/MAS/cvb Attachment cc: Dr. J. Nelson Grace, USNRC, Region II Harold F. Reis, Esquire, Newman & Holtzinger 8609120011 860904 PDR ADOCK 05000389 p PDR E JW I /002/ I PEOPLE SERVING PEOPLE
ATTACHMENT Re: St. Lucie Unit 2 Docket No. 50-389 Low Tem erature Over ressure Protection Question I Provide the results of the analyses performed for the St. Lucie Unit 2 plant for the most limiting mass and heat input transients with either Power Operated Relief Valves (PORVs) or Shutdown Cooling Systems (SDCS) relief valves mitigating including the following:
- a. Initial conditions and other major assumptions.
- b. Systems and components used for event mitigation.
- c. Sequence of events including time scale and system parameters.
- d. Compare the results of the transients to the acceptance criteria and show that overpressure protection is provided (i.e., does not violate Appendix G limits) over the range of conditions applicable to shutdown and heatup operations.
- e. Operator's action during the transients.
~Res onse I
- a. Results of the pressure transient analyses of the following over pressurization events provided the basis for the St. Lucie Unit 2 LTOP system:
RCP start (energy addition)
Two charging pump operation, (mass addition, Tc~200 F)
Inadvertent actuation of a HPSI pump, with simultaneous operation of three charging pumps (mass addition, Tc~200 F)
Initial conditions and major assumptions used in these pressure transient analyses are listed below:
E JW I /002/2
Res onse I (con't)
Initial RCS pressure = 300 psi
- 2. Pressurizer inventory is at 4I7.3 F, i.e., the saturation temperature at 300 psia. This temperature remains constant throughout each transient.
- 3. Only one PORV or SDCS relief valve (SDCSRV) is available for transient mitigation.
- 4. RCS is water-solid.
- 5. Letdown flow paths are isolated.
- 6. Full pressurizer heaters input and one percent decay heat are considered as additional heat sources.
- 7. There is no heat absorption or metal expansion at the reactor coolant pressure boundary.
- 8. PORV capacity is determined based on two discharge models:
'S'ubcooled water, flashing at outlet'odel, for PORV inlet pressures 600 psia,
'Subcooled water, non-flashing'odel for PORV inlet pressured 600 psia.
- 9. SDCSRV discharge model is consistent with the ASME Code requirements to relief valves, i.e., the valve opens at I03% of the set pressure, and a rated lift occurs at IOYo accumulation.
IO. Transients are analyzed up to the point in time, when the transient pressure is either stabilized or starts decreasing.
ln addition to the generic assumptions listed above, a number of transient-specific assumptions were used as follows:
E JW I /002/3
Res onse I (con't)
RCP Start Transient:
Secondary-to-primary temperature differential is 40 F.
- 2. PORV pops open instantaneously up to its full flow position as soon as a PORV setpoint is reached.
- 3. RCP heat input is considered as an additional heat source.
- 4. Pressure transient results of the computer code used to analyze these transients represent pressure transients at the relief valve inlets.
Mass Addition Transients:
Steam bubble in the pressurizer was assumed to mitigate the one HPSI and three charging pump transient, in addition to Assumption a.4.
- 2. Peak pressurizer pressures equal the equilibrium pressures if the latter exceed the relief valve opening pressures.
- 3. lf the equilibrium pressures are lower than the relief valve opening
=
pressures, peak pressurizer pressures equal the valve opening pressures (corrected for the PORV inlet piping pressure drops) for transients with the PORV; or the difference in elevations between the SDCSRV and pressurizer for transients with SDCSRV.
- b. For transient mitigation, either a PORV (VI474 or VI475) or a'SDCSRV (V3666 or V3667) were assumed in the analyses.
- c. Attached Figures 3-I and 3-3 demonstrate RCP start pressure transients mitigated by a PORV with various setpoints and by a SDCSRV with the current setpoint of 350 psia, respectively.
E JW I /002/4
Res onse I (con't)
- d. Pressure transient analysis results, i.e., maximum transient pressures, were evaluated along with pressure/temperature curves to identify conditions which would provide adequate LTOP. So-called controlling pressures were used as the criteria in the evaluation.
The controlling pressure is a pressure limit which will not be exceeded during postulated worst-case overpressurization transients mitigated by a relief valve. Thus, for the SDCSRVs, with the current setpoint of 350 psia, a controlling pressure P = 343 psia was identified. Intersection of the horizontal line corresponding to P = 343 with the P/T limit curves for cooldown, for example, indicate the temperatures below which allowable cooldown rates are reduced to the values marked on the curves next to the subject curves on the left. (Refer to attached Figure I-4 of Reference 2).
It can be seen that, in the temperature range of I I2-l28 F, P is more limiting that the 75 F/hr cooldown curve, but less limiting that the I 00 F/hr curve. Therefore, in this temperature range, the maximum cooldown rate of 75 F/hr could be allowed.
Thus, applying various controlling pressures to pressure/temperature curves, allowable heatup/cooldown rates, temperature limits for these rates and
, relief valve alignment temperatures could be determined. These parameters represent operational limitations which should be followed to ensure adequate LTOP.
'I
- e. Where applicable operator action was assumed to mitigate a transient following the outset of the transient.
20'inutes E JW I/002/5
Question 2 Provide a description of the modified Low Temperature Overpressure Protection (LTOP) systems including the subsystem with PORV's and the subsystem with SDCS relief valves. Attach updated Piping and Instrumentation Diagrams (P&IDs) of the systems involved.
~Res onse 2 The modified LTOP configuration includes SDCS relief valves V3666 and V3667, with the current setpoint of 350 psia, and PORVs V I474 and V I475, with a single setpoint of 470 psia.
The SDCSRVs are required to be aligned to the RCS for LTOP at Tc ~ 42 F, during heatup, and at Tc ( l6l F during cooldown. The PORVs are required to be aligned at l42 F~T ~ 295 F, during heatup, and at l6I F~T ~ 286 F, during cooldown. Note that the above temperature limits refer to the operating period up to 5 EFPY. For other operating periods, see Reference 3, Tables I thru 7.
It should also be noted that these temperatures are important indicators to watch, especially for cooldown, when failure to take proper actions could result in challenging the Technical Specification P/T limits should an overpressurization event occur. This is demonstrated below using these 5 EFPY temperature limits for illustration.
Durin cooldown upon approaching Tc = 286 F, an action is required to verify that both PORV setpoints are switched from the high pressure setpoint used for normal operaton.to the low pressure LTOP setpoint of 470 psia. This temperature, 286 F, identifies the maximum LTOP temperature during cooldown.
Tc = l6I F indicates a limit, below which the PORV setpoint of 470 psia could no longer provide adequate LTOP without a possibility of exceeding the 5 EFPY P/T limits. Consequently, upon approaching this temperature, an action is required to verify that both SDCSRVs are aligned to the RCS. The PORVs could also remain aligned but the primary means of LTOP are the SDCSRVs.
E JW I /002/6
c l~
Res onse 2 (con't)
The SDCSRVs must remain aligned during cooldown until (I) the reactor vessel head is off, or (2) the RCS is depressurized with an RCS vent of greater than or equal to 3.58 sq. in.
T =l42Fi i
- li; IPQRV with the setpoint of 470 psia could take over the LTOP function from the SDCSRVs. Failure to switch to this setpoint would not create a concern over LTOP. Longer operation under limited pressure conditions such as those prescribed by the SDCSRVs would be the only drawback.
Once the SDCS is secured, the PORVs become the primary means of LTOP. The LTOP setpoint of 470 psia must be maintained up until the RCS temperature reaches Tc = 295 F, at which time the PORV setpoint could be switched back to that used for normal operation. This temperature identifies the maximum LTOP temperature during heatup.
Since no hardware changes are needed to implement the modified LTOP system, the pertinent P &IDs remain unchanged and can be referred to in the St. Lucie Unit 2 Final Safety Analysis Report.
E JW I /002/7
Question 3 Discuss the shutdown and startup plant operating procedures with respect to the instructions for aligning the" LTOP systems. Specify the temperatures at which the LTOP systems will be aligned.
~Res onse 3 Operating Procedure 2-0030I27, "Reactor Plant Colldown - Hot Standby to Cold Shutdown", provides instructions for the cooldown of the reactor coolant system (RCS) from hot standby to cold shutdown. The procedure states that the aligning of the LTOP system is to be preceded by a functional test of the PORV actuation channels as per Instrument and Control (IB C) Procedure 2-I 200054, "Low Temperature Overpressure Protection Setpoint Verification." At this point, the procedure states that the test is to be performed prior to reaching 280oF; a procedure change request is being issued which will be instituted at the time of the license amendment issuance that changes this temperature to be within the limits specified in the response to question two of this submittal, namely l6I F ~ Tc ~ 286 F An administrative control is imposed by the procedure which states that cooldown is to be suspended until the channel checks are performed.
Instructions are then given to select the "LTOP" setting for the PORV valves; the procedure states that the annunciator will alarm at 280 F, alerting the operator to the need to activate the LTOP system. Annunciation setpoints will be changed and the procedure changed when the license amendment is issued to reflect the new LTOP actuation settings.
After the selection of the LTOP setting for the PORV's, RCS pressure is reduced to approximately 260 psia to allow for. the simultaneous operation of the reactor coolant pumps and entry into shutdown cooling. The operator is cautioned to ensure that the RCS hot leg suction valves (V365I, 3652, 3480, and 348I) are open before reducing RCS, temperature below I52 F to ensure LTOP protection. As indicated in the response to Question 2, this step of the procedure will be altered to reflect the new limits as given. The lineup of the hot leg suction valves ensures the availability of the SDCRV's to relieve overpressure.
E JW I /002/8
. ~
Res onse 3 (con't)
Additional overpressure protection is provided in Operating Procedure 2-00l0l25, "Schedule of Periodic Tests, Checks and Balances." A shift surveillance is performed to ensure that a manual vent of ~ 3.58 sq. in. remains open when required for overpressure protection.
During heatup, extensive system venting is performed if required once the RCS is filled, and temperature is raised to 325 F whereupon shutdown cooling is isolated. At approximately 320, annunciators will alarm, alerting the operator to select the "normal" setting on the PORV valve switches, thus returning the PORVs to the normal high pressure setting.
E Jw l /002/9
Question 4 Discuss the technical specifications for the modified LTOP systems operability and necessary Limiting Conditions for Operation (LCO) for plant protection from overpressure during shutdown and startup operations.
~Res onse 4 The response to Question 2 defines the modified LTOP configuration as consisting of the two SDCRY's, Y3666 and Y3667, and the two PORV's, V I474 and V 1475.
The LCO's specifically relating to the PORY's and overpressure protection are a part of the proposed license amendment and are directly available to the reviewers.
The shutdown cooling relief valves are a part of the shutdown cooling system, and are considered to be a part of the individual shutdown cooling loops. These loops are required to be available, in various configurations, in modes 4 through 6. As the SDCRV's are passive components of these systems, no specific LCO addresses the valves. Surveillance requirements are covered under specification 4.0.5; as the valves are the Quality Class B, they are included as Class 2 equipment and must meet the specifications of ASME Code Section Xl.
EJ W 1 /002/ l 0
Question 5 Discuss all administrative controls required to implement the LTOP systems.
~Res onse 5 The administrative controls necessary to provide LTOP are procedural in nature, and are discussed in the response to Question 3.
Procedural controls require that the LTOP system be aligned when the RCS pressure/temperature parameters fall within the bounds given by the appropriate pressure/temperature curves. Initially, the PORV's are aligned via a valve selection switch to the "LTOP" position; no further administrative controls are required as the PORV's will remain in this configuration while the RCS is at low temperatures and the reactor vessel head secured.
Procedural controls also govern the SDCRV's; shutdown cooling is required to be available through modes 4 to 6. As stated in the response to Question 5, a procedural requirement is given for the entry point into shutdown cooling according to the appropriate pressure/temperature curve parameters.
E JW I /002/ I I
Question 6 Demonstrate that water solid overpressure transients will not exceed I I0% of the design pressure of any component in the SDCS.
~Res onse 6 Water-solid overpressure transients will not exceed I IO percent of the design pressure of any component in the SDCS. Justification is provided below.
At the lower RCS temperatures such as those below l42 F during heatup and below l61 F during cooldown, for operation up to'5 EFPY, the most limiting postulated overpressurization event is the RCP start transient, with a secondary-to-primary ~t of 40 F. The maximum pressurizer pressure during this transient when mitigated by one SDCSRV is 342.7 psia, per Reference 2, page 38. Note that this pressure is the basis for establishing the controlling pressure of 343 psia which is discussed earlier in the response to Question I, Item d. Also note that this pressure refers to the pressurizer upper instrument nozzle elevation.
The most limiting SDCS design pressure was assumed to equal 350 psig, which is the LPSI pump maximum suction pressure, per Reference 4, Table 6.3-I, and also the SDCS suction piping design pressure. Note that this pressure refers to the LPSI pump suction centerline. The value of I IO percent of this pressure is I.I x 350 = 385 psig, or 399.7 psia.
To make a comparison, the maximum transient pressure of 342.7 psia is adjusted to the LPSI pump suction centerline elevation, which is approximately 82 ft. below the pressurizer upper instrument nozzle elevation, per References 5, 6, 7, and 8.
The corresponding static head at a conservatively assumed temperature of I 00 F is (82) x (62.035)/l44 = 35.3 psi.
Accordingly, the maximum transient pressure adjusted to the LPSI pump cehterline is 342.7 + 35.3 = 378.0 psia, which is less than I IO percent of the most limiting SDCS design pressure of 399.7 psia.
I Refer to Tables I thru 7, of FPL letter L-86-28I, dated July l5, l986, for these and similar temperature limits for other operating periods.
E JW I /002/ I 2
Question 7 Describe how the flashing of water at the discharge of the SDCS relief valve has been accounted for in the sizing of the valve or in the overpressure analysis.
~Res onse 7 The SDCSRV discharge model used in the pressure transient analyses was based on liquid discharge, i.e., subcooled water with no flashing all the way through the valve outlet.
As indicated in the response to Question I, Item a, the initial RCS pressure of 300 psia was assumed in the pressure transient analyses. The corresponding saturation temperature is approximately 4 I7 F.
The SDCSRVs are required to be aligned to the RCs for LTOP up to a RCS temperature (Tc) between I 6 I F and 207 F for 5 EFPY and 32 EFPY, respectively, per Reference 3, Tables I thru 7. Accordingly, during SDCSRV discharge, minimum water subcooling at the valve inlet will be 256 F and 2IO F, respectively.
Based on test data, such a degree of subcooling is considered high enough to sustain liquid flow through the valve outlet. It should be noted that due to the valve excessive rated capacity, i.e., 2300 gpm at the setpoint of 335 psig, per Reference 4, page 6.3-9, the pressure transients are mitigated even before the rated lift is reached. The valve discharge model is outlined in the response to Question I, Item a.
E JW I /002/ I 3
Question 8 Discuss the adequacy of the margin between the maximum pressure resulting from an overpressurization event and the setpoint for the automatic isolation of the shutdown cooling system.
~Res onse 8 Per Reference 4, Subsection 7.6.l.l, the SDCS suction isolation valves are interlocked with pressurizer pressure such that they will automatically close as RCS pressure increases above 500 psia.
E As indicated in the response to Question 6, the maximum pressurizer pressure during the most limiting overpressure transient mitigated by one SDCSRV is 342.7 pSI ae Comparison of the above pressure values shows that a margin of approximately l57 psi exists between the maximum. transient pressure and the pressure at which the SDCS is automatically isolated. This margin is considered to be more than adequate to preclude losing ETOP during startup and cooldown operations.
Note that the pressure signals to the interlocks are provided by the same pressure channels which are used for pressurizer pressure indication.
E JW I /002/ l 4
Question 9 Describe the alarms provided to alert the operator to:
- a. Properly enable the systems at the correct plant conditions during cooldown.
- b. Indicate if a pressure transient is occurring.
~Res onse 9 LTOP System Alarms-
- a. PORV LTOP Condition Alarm During cooldown when the "Mode Selector Switch" is in the "Normal" position and cold leg temperature reaches the new setpoint determined by the applicable P/T curve, a "PORV LTOP Condition" alarm will alert the operator to select "LTOP" on the "Mode Selector Switch", thus changing the PORV actuation setpoint from 2370 psia to 470 psia for VI474 and VI475.
This alarm will not reset unless the PORV mode selector switch is in the
,"LTOP" position and the motor operated isolation valve of the associated PORV is "OPEN".
- b. PORV Normal Condition Alarm During heatup when the "Mode Selector Switch" is in the "LTOP" position and cold leg temperature is greater than 320 F, a "PORV Normal Condition" alarm will alert the operator to select "Normal" on the "Mode Selector Switch"; thus changing the PORV actuation setpoint from 470 psia for V I474 and VI475 to 2370 psia. This alarm will not reset unless the PORV Mode Selector Switch is in the "Normal" position and its associated isolation valve is "OPEN". Therefore, one alarm will be lit during normal operation as long as one PORV remains isolated.
Co LTOP Transient Alarm When RCS temperature (cold leg) is less than the given setpoint or the mode selector switch is in "LTOP" and pressurizer pressure is greater than 460 psia, an LTOP transient is occurring, actuating the "LTOP Transient" alarm.
- d. PORV Test Condition Alarm A "PORV Test Condition" alarm will alert the operator whenever the PORV E J W I /002/ I 5
- ~
Res ons'e 9 (con't) protective system is in the "Override" or "Test" position, bypassing all setpoints. The PORV will remain closed in this condition until the selector switch is placed in the "OFF" position at which time the alarm will reset.
- e. Indicating Lights Open and close position indicating lights hove been located in the control room, informing the operator of the actual stem position of each PORV.
Indicating lights are not energized or deenergized from the solenoid valve circuitry. Indicating lights are controlled from the valve stem position.
Each isolation valve is provided with a two-position open-close switch for valve operation. Open and close position indicating lights are also provided for each motor operated isolation valve.
A test indicating light will be provided for each PORV and let whenever the PORV protective system control circuitry has been bypassed (in "OVERRIDE") or has been tested satisfactorily.
E JW I /002/16
A Question I 0 To assure operational readiness the LTOP system must be tested in the following manner:
- a. A test must be performed to assure operability of the system's electronics prior to each shutdown.
- b. A test for 'valve operability must, as a minimum, be conducted as specified in the ASME Code Section XI.
Res onse IO As was mentioned in the response to Question 3, PORV channel checks are performed by the Instrument and Control department before reaching the PORV LTOP actuation temperature and before the reactor head may be reset after refueling or head 'removal. This specification is included in the license amendment proposed by FPL for St. Lucie Unit 2.
The SDCRV's are Quality Class B, Class 2 valves and are therefore surveilled according to Technical Specification 4.0.5 within the requirements of ASME Code Section Xl.
E JW I /002/I 7