ML120740031

From kanterella
Jump to navigation Jump to search

3/29/12 Notice of Meeting Viaconference Call with STP Nuclear Operating Company to Discuss Risk-Informed GSI-191, Assessment of Debris Accumulation on Pressurized-Water Reactor (PWR) Sump Performance, Resolution Approach for Units 1 and 2
ML120740031
Person / Time
Site: South Texas  
(NPF-076, NPF-080)
Issue date: 03/15/2012
From: Balwant Singal
Plant Licensing Branch IV
To: Markley M
Plant Licensing Branch IV
Singal, Balwant, 415-3016, NRR/DORL/LPL4
References
TAC ME7735, TAC ME7736
Download: ML120740031 (4)


Text

MEMORANDUM TO:

FROM:

SUBJECT:

DATE & TIME:

LOCATION:

PURPOSE:

CATEGORY*:

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 15, 2012 Michael T. Markley, Chief Plant licensing Branch IV Division of Operating Reactor licensing Office of Nuclear Reactor Regulation Balwant K. Singal, Senior Project Manager t:, C?oo...\\ ~l t ~~~

Plant licensing Branch IV Division of Operating Reactor licensing Office of Nuclear Reactor Regulation FORTHCOMING PUBLIC MEETING VIA CONFERENCE CALL WITH STP NUCLEAR OPERATING COMPANY (TAC NOS. ME7735 AND ME7736)

Thursday, March 29, 2012 1 :00 p.m. - 4:00 p.m.

U.S. Nuclear Regulatory Commission 11555 Rockville Pike, Room 0-08B6 Rockville, Maryland Follow-up discussion to the public meeting held on March 8, 2012, between STP Nuclear Operating Company (STPNOC) and U.S.

Nuclear Regulatory Commission (NRC) staff to discuss Generic Safety Issue (GSI) 191, "Assessment of Debris Accumulation on PWR [Pressurized-Water Reactor] Sump Performance."

STPNOC will discuss a risk-informed GSI-191 resolution option approach regarding South Texas Project, Units 1 and 2.

This is a Category 1 Meeting via conference call. The public is invited to participate in this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned.

  • Commission's Policy Statement on "Enhancing Public Participation in NRC Meetings" (67 FR 36920), May 28, 2002,

M. Markley PARTICIPANTS:

- 2 Participants from the NRC include members of the Office of Nuclear Reactor Regulation (NRR).

NRC STPNOC S. Bailey B. Letellier K. Howe S. Dinsmore S. Blossom J. Leavitt D. Harrison E. Kee G. Zigler P. Klein

1. Sande C. Sellers M. Yoder Z. Mohaghegh C. Grantom M. Snodderly J. Paul et. al S. Smith E. Geiger B. Singal, et al.

Interested members of the public can participate in this meeting via a toll-free audio teleconference. Please e-mail or call (e-mail preferred) one of the meeting contacts listed below before March 27,2012, 3:00 p.m. (Eastern Standard Time), to get the telephone number and the pass code.

MEETING CONTACTS:

Balwant K. Singal, NRR Mohan Thadani, NRR 301-415-3016 301-415-1476 Balwant.Singal@nrc.gov Mohan. Thadani@nrc.gov The NRC provides reasonable accommodation to individuals with disabilities where appropriate.

If you need a reasonable accommodation to partiCipate in a meeting, or need a meeting notice or a transcript or other information from a meeting in another format (e.g., Braille, large print),

please notify the NRC's meeting contact. Determinations on requests for reasonable accommodation will be made on a case-by-case basis.

To receive a summary of this meeting and begin receiving other plant-specific e-mail distributions, you must subscribe to the Operating Reactor Correspondence electronic distribution for this plant via http://www.nrc.gov/public-involvellistserver/plants-by-region.html.

Once subscribed, if you wish to discontinue receiving electronic distribution, you may unsubscribe at any time by visiting the same web address above.

Docket Nos. 50-498 and 50-499

Enclosure:

Agenda cc w/encl: Distribution via Ustserv

AGENDA FORTHCOMING PUBLIC MEETING VIA CONFERENCE CALL WITH STP NUCLEAR OPERATING COMPANY AND U.S. NUCLEAR REGULATORY COMMISSION SOUTH TEXAS PROJECT UNITS 1 AND 2 DOCKET NOS. 50-498 AND 50-499 THURSDAY, MARCH 29,2012 1:00 p.m. - 4:00 p.m.

Introductions

Discussion of Generic Safety Issue (GSI)-19'1 bypass testing and head loss protocols and plans for the South Texas Project pilot program*.

Discussion on resolution of the outstanding chemical effects phenomena identification and ranking table (PIRT) issues*.

NRC staff input.

Public comments.

Adjourn.

Please refer to the following Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML120610074 and ML120540727 for materials provided by STPNOC for purposes of discussion of these topics.

Enclosure

ML120740031

  • via email II OFFICE DORULPL4/PM DORULPL4/LA DORULPL4/BC DORULPL4/PM I NAME BSingal JBurkhardt*

MMarkley BSingal

! DATE 3/15/12 3/15/12 3/15/12 3/15112