Additional Questions from the Containment and Ventilation Branch on the Proposed EPU Amendment
ML100980009
Person / Time
Site: Monticello 
Issue date: 04/06/2010
From: Tam P
Plant Licensing Branch III
To: Gunderson L, Schaefer K
Northern States Power Co
Tam P
References
TAC MD9990
Download: ML100980009 (2)


Text

Accession No. ML100980009 From:

Tam, Peter Sent:

Tuesday, April 06, 2010 5:22 PM To:

Schaefer, Kurt T.; Gunderson, Lynne Cc:

Sallman, Ahsan; Lobel, Richard

Subject:

Monticello - Additional Draft RAI from the Containment and Ventilation Branch (TAC MD9990)

Kurt:

The Containment and Ventilation Branch (SCVB) is reviewing your 11/5/08 application, as supplemented. SCVB has generated the following 4 additional draft questions on the submitted information. Please set up a conference with me to discuss these draft questions:

1. Please provide the normalized reactor power versus time used for Monticello's anticipated transient without scram (ATWS) containment NPSH analysis under EPU conditions described in Section 2.6.5 of NEDC-33322P, Revision 3, submitted via the 11/5/08 application.
2. Please provide events versus time used in the ATWS PROFO Case 1, PROFO Case 2, and LOOP analyses under EPU conditions described in Section 2.6.5 of NEDC-33322P, Revision 3, submitted via the 11/5/08 application.
3. Referring to the 11/5/08 application, please provide the limiting value of head loss in the RHR system from the reactor to the pump inlet while operating in the normal shutdown cooling mode at the operating values of system flows under EPU conditions.
4. Refer to the GEH topical report NEDC-33347P, Revision 0, submitted via letter dated 2/15/08 by the BWROG (ADAMS Accession No. Ml080520261), Section 3.1.2-Statistical Approach with Realistic Assumptions. How is the decay heat input sampled for the 59 Monte Carlo runs?

The sole purpose of this e-mail is to prepare you and others for the proposed conference call.

This e-mail does not at this time convey an NRC staff position, and does not formally request for information.

Peter S. Tam Senior Project Manager (for Kewaunee and Monticello)

Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Tel. 301-415-1451 E-mail Properties

Mail Envelope Properties (3D6B1F4F51D25E4E9B6C93FF92DAE5171443BF7E52)

Subject:

Monticello - Additional Draft RAI from the Containment and Ventilation Branch (TAC MD9990)

Sent Date: 4/6/2010 5:21:32 PM Received Date: 4/6/2010 5:21:00 PM From: Tam, Peter Created By: Peter.Tam@nrc.gov Recipients:

Kurt.Schaefer@xenuclear.com (Schaefer, Kurt T.)

Tracking Status: None Lynne.Gunderson@xenuclear.com (Gunderson, Lynne)

Tracking Status: None Ahsan.Sallman@nrc.gov (Sallman, Ahsan)

Tracking Status: None Richard.Lobel@nrc.gov (Lobel, Richard)

Tracking Status: None Post Office:

HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 10755 4/6/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: