Job Performance Measure Perform the MSIV Closure Timing Test JPM Number:

Date:

CR JPM a.doc Page 1 of 9

Job Performance Measure (JPM)

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST DELETE THIS Page!!!

NOTE: All steps of this checklist should be performed upon initial validation.

Prior to JPM usage, revalidate JPM using steps 8 through 11 below.

________ 1. Task description and number, JPM description and number are identified.

________ 2. Knowledge and Abilities (K/A) references are included.

________ 3. Performance location specified. (in-plant, control room, or simulator)

________ 4. Initial setup conditions are identified.

________ 5. Initiating and terminating cues are properly identified.

________ 6. Task standards identified and verified by SME review.

________ 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).

________ 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:

Procedure Rev. _____ Date _____________

________ 9. Pilot test the JPM:

a. verify cues both verbal and visual are free of conflict, and
b. ensure performance time is accurate.

________ 10. If the JPM cannot be performed as written with proper responses, then revise the JPM.

________ 11. When JPM is revalidated, SME or Instructor sign and date JPM cover page.

SME/Instructor Date SME/Instructor Date SME/Instructor Date CR JPM a.doc Page 2 of 9

Job Performance Measure (JPM)

SIMULATOR SETUP INSTRUCTIONS

1. Reset the simulator to IC 19 (rst __).
2. IC

Description:

The unit is operating < 75% power and < 97% FCL ~ 680 Mwe.

NOTE: It is okay to use a similar IC to the IC listed above, provided the IC actually used is verified to be compatible with this and other JPMs that are scheduled to be run concurrently.

3. Run the setup Computer Aided Exercise _____-__ (jcae! _____-__)
4. Manual Actuation:

Reduce power as necessary to ensure plant is less than 75%. ( 680 Mwe) and

<97% FCL.

Annotate QCOS 0250-04 to indicate testing of AO 1-203-1A and AO 1-203-1B only.

(Add second valve)

5. Malfunctions:

Slow stroke 1-203-1B, valve strokes at >5.2 seconds. First valve times OK!

6. Remotes:

None.

7. Overrides:

None.

8. When the above steps are completed for this and other JPMs to be run concurrently, then validate the concurrently run JPMs using the JPM Validation Checklist.
9. This completes the setup for this JPM.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM a.doc Page 3 of 9

Job Performance Measure (JPM)

INITIAL CONDITIONS

- The unit is operating at __________ power.

- The Unit Supervisor has directed the MSIV Closure Timing Test be performed on AO 1-203-1A due to a previous slow closure time.

- There are no personnel in the MSIV Room.

- This JPM is not time critical. Delete this!

INITIATING CUE Perform the MSIV Closure Timing surveillance on AO 1-203-1A and AO 1-203-1B, (add this) IAW QCOS 0250-04.

Provide examinee with:

QCOS 0250-04 with steps D.1.a., b., & c. filled in, annotated for testing of MSIV AO 1-203-1A and MSIV AO 1-0250-04 (?) only in step D.1.b.

Electronic Stopwatch.

Fill in the JPM Start Time when the student acknowledges the Initiating Cue.

Information For Evaluators Use:

UNSAT requires written comments on respective step.

  • Denotes CRITICAL steps.

Number any comments in the Comment Number column on the following pages. Then annotate that comment in the Comments section at the bottom of the page. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.

Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.

The timeclock starts when the candidate acknowledges the initiating cue.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM a.doc Page 4 of 9

Job Performance Measure (JPM)

JPM Start Time:

PERFORMANCE OBJECTIVE STANDARDS SAT UNSAT N/A D.2.a. Reactor power is <75%. Verifies Reactor power <75%. [] [] []

D.2.b. Flow control line is <97%. Verifies FCL <97%. [] [] []

  • H.1.a. Determine that MSIV will Determines that proper criteria [] [] []

be tested using hot for testing is hot criteria.

criteria.

H.2.a. Activate MSIV Test Activates MSIV Test Mode. [] [] []

Mode at Operator Work Station FWLC Measuring Point Display.

H.2.b. Verify reactor level Observe water level ind. stable [] [] []

maintained H.2.c. Verify that sum of Verifies that green filled [] [] []

individual steam flows square at the DWS FWLL being used for total steam measuring point display flow. labeled as Act indicated sum of individual steam flows.

H.3.a. Verify open AO 1-203-1A. Verifies AO 1-203-1A is open. [] [] []

  • H.3.b. *Close and time AO 1-203- AO 1-203-1A Normal Control [] [] []

1A.* Switch positioned to close AND stop watch actuated to time the valve stroke.

EVALUATOR NOTE: The stopwatch must be started at same time as control switch actuation.

H.3.c. Record closure time on Records closure time on step [] [] []

Attachment A. H.3.b. to nearest 1/100 of a second.

CUE: Inform candidate that Switch to Light time for the MSIV is 5.1 seconds. Delete this, he should be able to read a stop watch!!

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM a.doc Page 5 of 9

Job Performance Measure (JPM)

PERFORMANCE OBJECTIVE STANDARDS SAT UNSAT N/A Add duplicate steps for stroking B MSIV. B MSIV will slow stroke!

Attachment A Unit Supervisor to evaluate Unit Supervisor evaluates. [] [] []

whether valve is to be re-adjusted or retested.

EVALUATOR: JPM will end with recognition by candidate that either further testing or valve adjustment is necessary before proceeded.

  • CRITICAL STEP JPM Stop Time:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM a.doc Page 6 of 9

Job Performance Measure (JPM)

Operators Name:

Job

Title:

o NLO o RO o SRO o STA Delete!

o SRO Cert Delete!

JPM

Title:

Perform the MSIV Closure Timing Test JPM Number: Revision Number:

Task Number and

Title:

Given a reactor plant at power, conduct MSIV closure timing in accordance with QCOS 0250-04.

K/A Number and Importance:

K/A: 239001 A4.01 Rating: 4.2/4.0 Suggested Testing Environment: Simulator Actual Testing Environment: n Simulator o Plant o Control Room Testing Method: o Simulate Faulted: o Yes n No n Perform Alternate Path: o Yes n No Time Critical: o Yes n No Estimated Time to Complete: 12 minutes Actual Time Used: minutes

References:

QCOS 0250-04 Rev. 15, MSIV Closure Timing G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM a.doc Page 7 of 9

Job Performance Measure (JPM)

EVALUATION

SUMMARY

Were all the Critical Elements performed satisfactorily? o Yes o No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be: o Satisfactory o Unsatisfactory Comments:

Evaluators Name: (Print)

Evaluators Signature: Date:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM a.doc Page 8 of 9

Job Performance Measure (JPM)

INITIAL CONDITIONS (Student Copy)

- The unit is operating at __________ power.

- The Unit Supervisor has directed the MSIV Closure Timing Test be performed on AO 1-203-1A and AO 1-203-1B due to a previous slow closure time.

- There are no personnel in the MSIV Room.

- This JPM is not time critical. Delete!

INITIATING CUE Perform the MSIV Closure Timing surveillance on AO 1-203-1A, IAW QCOS 0250-04.

Page 9 of 9

Job Performance Measure Roll The Turbine JPM Number:

Date:

CR JPM b.doc Page 1 of 8

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST DELETE THIS PAGE!

NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 and 11 below.

________ 1. Task description and number, JPM description and number are identified.

________ 2. Knowledge and Abilities (K/A) references are included.

________ 3. Performance location specified. (in-plant, control room, or simulator)

________ 4. Initial setup conditions are identified.

________ 5. Initiating and terminating cues are properly identified.

________ 6. Task standards identified and verified by SME review.

________ 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).

________ 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:

Procedure Rev. _____ Date _____________

________ 9. Pilot test the JPM:

a. verify cues both verbal and visual are free of conflict, and
b. ensure performance time is accurate.

________ 10. If the JPM cannot be performed as written with proper responses, then revise the JPM.

________ 11. When JPM is revalidated, SME or Instructor sign and date JPM cover page.

SME/Instructor Date SME/Instructor Date SME/Instructor Date Page 2 of 8

INITIAL CONDITIONS

- The Control Room is performing a Unit 1 startup IAW QCGP 1-1, Normal Unit Startup.

- QCGP 1-1 has been performed up through and including F.7.r.

- First Stage Bowl upper inner surface temperature is greater than 360 degrees F.

- You have been instructed to roll the turbine and achieve a speed of 1800 rpm.

INITIATING CUE Roll the Main Turbine and achieve a speed of 1800 rpm.

Provide Examinee With:

A copy of QCGP 1-1.

Fill in the JPM Start Time when the student acknowledges the Initiating Cue.

Information For Evaluators Use:

UNSAT requires written comments on respective step.

  • Denotes critical steps.
  • Denotes critical elements of a critical step.

Number any comments in the Comment Number column on the following pages. Then annotate that comment in the Comments section at the bottom of the page. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.

Page 3 of 8

JPM Start Time:

Comment SAT UNSAT Number STEP ELEMENT STANDARD CUE: The announcement has just been made for the impending Main Turbine roll.

  • F.7.t. Press FAST pushbutton on Depresses the FAST pushbutton on ___ ___ ___

STARTUP RATE. the 901-7 panel.

  • F.7.u. Press the 1800 rpm pushbutton Depresses the 1800 rpm ___ ___ ___

on SPEED SET RPM. pushbutton.

F.7.u.(1) Verify that MAIN STOP VLV Verifies MAIN STOP VLV #2 ___ ___ ___

  1. 2 opens. opens.

F.7.u.(2) Verify that MAIN STOP VLVs Verifies that MAIN STOP VLV #2 ___ ___ ___

  1. 1, #3, and #4 ramp open. reaches 100% open and then MAIN STOP VLVs #1, #3, and #4 begin to ramp open.

F.7.u.(3) Verify COMBINED INTER Verifies COMBINED INTER ___ ___ ___

STOP VLVs #1, #3, and #5 STOP VLVs #1, #3, and #5 begin ramp open. to ramp open.

F.7.u.(4) Verify COMBINED INTER Verifies COMBINED INTER ___ ___ ___

STOP VLVs #2, #4, and #6 STOP VLVs #1, #3, and #5 reach ramp open. 100% open and then COMBINED INTER STOP VLVs #2, #4, and #6 begin to ramp open.

F.7.u.(5) Verifies CONTROL VLVs After all MAIN STOP VLVs and ___ ___ ___

open. COMBINED INTER VLVs are full open, verifies CONTROL VLVs opens and rolls the Turbine off the turning gear.

  • F.7.v. Press 180 RPM/Minute startup 180 RPM/Minute startup rate ___ ___ ___

rate. depressed.

EVALUATOR: Candidate should select startup speed of 180 RPM/Minute based upon greater than 350 degrees First Stage Bowl upper inner surface temperature.

F.7.w. Verify that the Main Turbine is Verifies Main Turbine is ___ ___ ___

accelerating. accelerating at 180 RPM/Minute.

Page 4 of 8

Comment SAT UNSAT Number STEP ELEMENT STANDARD F.7.x. Verify Chest Warming has Verifies that Chest Warming goes ___ ___ ___

stopped. to zero as indicated on MAIN STOP VLV POS DEMAND FOR CHEST/SHELL WARMING indication.

F.7.y. Ensure that Main Turbine Checks Main Turbine vibration on ___ ___ ___

vibration is acceptable. recorder 1(2)-5640-60, ECCENTRICITY AND VIBRATION, during acceleration.

EVALUATOR: Vibration monitor should read less than 10 mils.

CUE: If vibration monitor is not reading less than 10 mils or has no signal, tell candidate that vibration monitor is indicating 8 mils.

  • F.7.z. At critical speed, select FAST When Main Turbine speed ___ ___ ___

on STARTUP RATE. approaches the critical speed, select FAST on STARTUP RATE.

EVALUATOR: For Unit 1, critical speed is approximately 950 rpm; for Unit 2, critical speed is approximately 1100 rpm.

  • F.7.aa. After the critical speed, depress Depresses the 180 RPM/Minute ___ ___ ___

180 RPM/Minute startup rate. startup rate pushbutton after the Main Turbine has passed through the critical speed.

F.7.ab. Verify the Turning Gear Motor Verifies that the Turning Gear ___ ___ ___

is off. Motor is off.

F.7.ac.(1) Verify Turbine oil temperature After Turbine speed levels out at ___ ___ ___

is approximately 115 degrees F approximately 1800 rpm, verifies on TI 1(2)-5140-14, OIL turbine oil temperature.

COOLER OUTLET TEMP.

F.7.ac.(1) Verify that Turbine vibrations Turbine vibrations verified less ___ ___ ___

are less than 5 mils. than 5 mils.

Page 5 of 8

Comment SAT UNSAT Number STEP ELEMENT STANDARD Add: Comment: Candidate will check vibration monitor at this step. If vibration monitor is not reading less than 5 mils or has no signal, tell candidate that vibration monitor is indicating 4 mils.

Delete!

EVALUATOR: The candidate should inform you that the task is complete.

JPM Stop Time:

Page 6 of 8

Operators Name:

Job

Title:

NLO RO SRO STA SRO Cert Delete these JPM

Title:

Roll the Main Turbine JPM Number:

Task Number and

Title:

Given that the plant is starting up and QCGP 1-1 has been completed up to and including stepF.7.r, roll the Main Turbine and achieve a speed of 1800 rpm.

K/A Number and Importance:

K/A: 295031.EA1.02 Rating: 4.5 / 4.5 Suggested Testing Environment: Plant Actual Testing Environment: Simulator Control Room In-Plant Testing Method: Simulate Alternate Path: Yes No Perform SRO Only: Yes No Time Critical: Yes No Estimated Time to Complete: 27 minutes Actual Time Used: minutes

References:

QCOP 2300-08, Rev. 20, HPCI LOCAL MANUAL OPERATION EVALUATION

SUMMARY

Were all the Critical Elements performed satisfactorily? Yes No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be: Satisfactory Unsatisfactory Comments:

Evaluators Name: (Print)

Evaluators Signature: Date:

Page 7 of 8

INITIAL CONDITIONS

{Student Copy}

- The Control Room is performing a Unit 1 startup IAW QCGP 1-1, Normal Unit Startup.

- QCGP 1-1 has been performed up through and including F.7.r.

- First Stage Bowl upper inner surface temperature is greater than 360 degrees F.

- You have been instructed to roll the turbine and achieve a speed of 1800 rpm.

INITIATING CUE Roll the Main Turbine and achieve a speed of 1800 rpm.

Page 8 of 8

TQ-AA-106-0303 Revision 1 Exelon Nuclear Job Performance Measure Perform the SBGT Monthly Operability Test With Failure of the Heater to Turn Off After Shutdown JPM Number: LS-042-I-F Revision Number: 10 Date: 06/30/05 Developed By:

Instructor Date Validated By:

SME or Instructor Date Review By:

Operations Representative Date Approved By:

Training Department Date CR JPM c.doc Page 1 of 11

TQ-AA-106-0303 Revision 1 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST DELETE THIS PAGE!

NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 and 11 below.

________ 1. Task description and number, JPM description and number are identified.

________ 2. Knowledge and Abilities (K/A) references are included.

________ 3. Performance location specified. (in-plant, control room, or simulator)

________ 4. Initial setup conditions are identified.

________ 5. Initiating and terminating cues are properly identified.

________ 6. Task standards identified and verified by SME review.

________ 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).

________ 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:

Procedure Rev. _____ Date _____________

________ 9. Pilot test the JPM:

a. verify cues both verbal and visual are free of conflict, and
b. ensure performance time is accurate.

________ 10. If the JPM cannot be performed as written with proper responses, then revise the JPM.

________ 11. When JPM is revalidated, SME or Instructor sign and date JPM cover page.

SME/Instructor Date SME/Instructor Date SME/Instructor Date CR JPM c.doc Page 2 of 11

TQ-AA-106-0303 Revision 1 Revision Record (Summary)

1. Revision 6, This JPM is developed IAW guidelines established in NUREG 1021 Rev 8 ES-301 and Appendix C. This JPM meets the criteria of Category B.1 "Control Room Systems," for RO/SRO candidates.
2. Revision 7, JPM updated to reflect procedure changes.
3. Revision 8, JPM updated to reflect procedure changes.
4. Revision 9, This JPM is being revised to reflect new format changes, using Local Indicators for data, stopping JPM after Fault and procedure changes.
5. Revision 10, JPM updated to reflect procedure changes and new estimated completion time.

Delete this page too!

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 3 of 11

TQ-AA-106-0303 Revision 1 SIMULATOR SETUP INSTRUCTIONS

1. Reset the simulator to IC ANY (rst __).

NOTE: It is okay to use a similar IC to the IC listed above, provided the IC actually used is verified to be compatible with this and other JPMs that are scheduled to be run concurrently.

2. Run the setup Computer Aided Exercise _____-__ (jcae! _____-__)
3. Manual Actuation:

SBGT Systems are lined up and in standby. On the 912-5 panel the mode select switch for the A is in STBY and B train is in the PRIM position.

Malfunctions: NONE Remotes: NONE Overrides:

Insert the following in order to simulate a failure of the heater to trip following train shutdown:

trg 10 SBGBHTRON ior loil07503b2(10) ON ior loil07503b1(10) OFF

4. When the above steps are completed for this and other JPMs to be run concurrently, then validate the concurrently run JPMs using the JPM Validation Checklist.
5. This completes the setup for this JPM.

This JPM must be able to run in parallel with other JPMs!

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 4 of 11

TQ-AA-106-0303 Revision 1 INITIAL CONDITIONS

- The plant is operating at _____ power.

- The SBGT systems are lined up for standby in accordance with QCOP 7500-01.

- Radiation Protection has been notified that SBGT will be started.

- NLO stationed at 1/2B SBGT for local actions.

INITIATING CUE Perform the SBGT System Monthly Operability Test for the 1/2B train per QCOS 7500-05.

Fill in the JPM Start Time when the student acknowledges the Initiating Cue.

Information For Evaluators Use:

UNSAT requires written comments on respective step.

  • Denotes critical steps.
  • Denotes critical elements of a critical step.

Number any comments in the Comment Number column on the following pages. Then annotate that comment in the Comments section at the bottom of the page. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.

Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.

The timeclock starts when the candidate acknowledges the initiating cue.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 5 of 11

TQ-AA-106-0303 Revision 1 JPM Start Time:

Comment SAT UNSAT Number STEP ELEMENT STANDARD H.2.a. Record B SBGT start time. Records current time. ___ ___ ___

H.2.b. Verify open U-1 RB INLET Determines both 1-7503 and ___ ___ ___

DMPR TO SBGT AND/OR U-2 2-7503 are open by open lights RB INLET DMPR TO SBGT being lit.

  • H.2.c. *Start B SBGTS.* Positions B train mode selector ___ ___ ___

switch to START.

H.2.d.(1) Verify closed TURB BLDG Verifies 1/2-7504B CLOSED light ___ ___ ___

CLG AIR DMPR. lit.

H.2.d.(2) Verify open INLET DMPR. Verifies 1/2-7505B OPEN light lit. ___ ___ ___

H.2.d.(3) Verify on SBGT AIR HTR. Verifies 1/2-7503B ON light lit. ___ ___ ___

H.2.d.(4) Verify on 1/2B SBGT FAN. Verifies 1/2-7506B ON light lit.

H.2.d.(5) Verify open SBGTS FAN Verifies 1/2-7507B OPEN light lit. ___ ___ ___

DISCH DMPR.

H.2.e. Verify proper SBGTS flow. Verifies 1/2-7541-13B indicates ___ ___ ___

3600-4400 scfm and records flow H.2.e.(1)

CUE: Inform the operator that 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> have passed.

SIM OP NOTE: Override the 1/2B SBGT heater T temp to 23°F by inserting override aoti 1754012b 58 H.2.f.(1) Record 1/2B SBGTS flow. Records 1/2B SBGTS flow from ___ ___ ___

1/2-7541-34b H.2.f.(2) Determine 1/2B SBGTS inlet Remotely from SBGTS B heater ___ ___ ___

temp. diff. temp indicator on Panel 912-5 OR TI 1/2-7540-12B.

CUE: SBGT DT is 23°F.

Directs NLO to obtain B train ___ ___ ___

upstream temp. from TI 1/2-7541-10B and records after cue.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 6 of 11

TQ-AA-106-0303 Revision 1 Comment SAT UNSAT Number STEP ELEMENT STANDARD CUE: B train upstream temperature is 82oF as indicated on TI-1/2-7541-10B.

Determine 1/2B SBGTS outlet Directs NLO to obtain B train ___ ___ ___

temp. outlet temp. from TI 1/2-7541-13B and records after cue.

CUE: B train downstream temperature is 105oF.

EVALUATOR: If the operator questions the fact that TI-1/2-7540-12B does not indicate near 23oF, inform him/her that this is due to the JPM time compression.

  • *Calculate heater dT.* Determines htr dT is 23oF by ___ ___ ___

subtracting inlet temp. from outlet temp. and records.

EVALUATOR: Sign the verification by for heater T.

H.2.g. Determine htr differential Determines htr dt > 14oF. Checks ___ ___ ___

temperature > 14oF. step H.2.g.

H.2.h. Record Demister dP (.95 + Directs NLO to obtain and report ___ ___ ___

.05(ave), 2.0(init WR) 1/2-7541- Demister dP. Records on surv.

9B CUE: dP is 1.0 as indicated on the 1/2-7541-9B.

H.2.i. Record Rough Prefilter Directs NLO to obtain and report ___ ___ ___

dP(.2(ave), 2.0(init IR)) Rough Prefilter dP. Records on 1/2-7541-12B surv.

CUE: dP is 0.3 as indicated on the 1/2-7541-12B.

H.2.j. Record High Eff. Prefilt. Directs NLO to obtain and report ___ ___ ___

dP(1.0(ave), 1.8(init. IR) High Eff. Prefilt. dP. Records on 1/2-7541-14B surv.

CUE: dP is 1.1 as indicated on the 1/2-7541-14B.

H.2.k. Record Carbon Iodine Absorb. Directs NLO to obtain and report ___ ___ ___

dP (.95 + 15(ave), 2.0(init IR), Carbon Iodine Absorb dP. Records 1/2-7541-16B on surv.

CUE: dP is 0.9 as indicated on the 1/2-7541-16B.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 7 of 11

TQ-AA-106-0303 Revision 1 Comment SAT UNSAT Number STEP ELEMENT STANDARD H.2.1. Record HEPA filter dP (1.0(ave), Directs NLO to obtain and report ___ ___ ___

1.8(init IR) 1/2-7541-18B HEPA Filter dP. Records on surv.

CUE: dP is 1.0 as indicated on the 1/2-7541-18B.

H.2.m. Calculate total Differential Calculates total dP to be 3.3. ___ ___ ___

Pressure. Records on surv.

Has number second verified.

EVALUATOR: Sign the verification for the Total DP.

H.2.n. Verify Total DP for SBGTS B is Verifies total dP to be 3.3. Marks ___ ___ ___

less than 6.0 inches of water. on surv.

H.2.o. Perform an inspection of the Directs the NLO to perform the ___ ___ ___

SBGTS train to identify any inspection.

discernable signs of leakage.

CUE: As the NLO, report that you do not see any discernable signs of leakage.

CUE: B train has now been running for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />. Secure B SBGTS.

  • H.2.p. *Shutdown B SBGTS.* Positions B train mode selector ___ ___ ___

switch to OFF.

EVALUATOR: In the next step, if the operator asks for the US, inform him that he is around the back panels of U-1.

  • CAUTION *Recognize failure of htr to turn Recognizes B train air htr ON ___ ___ ___

off and restarts B SBGT light lit for > 10 seconds Train.* THEN Restarts train by positioning B train mode selector switch to START.

Inform US. Tells the US that the htr did not ___ ___ ___

stop after shutting down the train and the train was restarted.

CUE: I understand the heater failed to trip following train shutdown. Leave the B train operating. I will prepare a work request and call maintenance to trouble shoot and inform the SM and leave B SBGT running until troubleshooting can commence.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 8 of 11

TQ-AA-106-0303 Revision 1 Comment SAT UNSAT Number STEP ELEMENT STANDARD CUE: The candidate may inform you the task is complete here.

H.2.q. Place 1/2 B Train in PRIM. Positions 1/2B SBGT selector ___ ___ ___

switch to PRIM.

H.2.r.(1) Record stop time. Records start time + 10.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />. ___ ___ ___

CUE: Give the candidate a time that is 10 hrs and 30 minutes later than the original time JPM Stop Time:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 9 of 11

TQ-AA-106-0303 Revision 1 Operators Name:

Job

Title:

NLO RO SRO STA SRO Cert JPM

Title:

Perform the SBGT Monthly Operability Test with Failure of the Heater to Turn Off After Shutdown JPM Number: LS-042-I-F Revision Number: 10 Task Number and

Title:

SR-7500-P01 (Freq: LIC=B) Given SBGTS in a standby lineup, perform the monthly SBGTS monthly operability test and return SBGTS to a standby line up in accordance with QCOS 7500-05.

K/A Number and Importance:

K/A: 261000 A.3.04 Rating: 3.0/3.1 Suggested Testing Environment: Simulator Actual Testing Environment: Simulator Control Room In-Plant Testing Method: Simulate Alternate Path: Yes No Perform SRO Only: Yes No Time Critical: Yes No Estimated Time to Complete: 17.5 minutes Actual Time Used: minutes

References:

QCOS 7500-05, Rev. 26, SBGTS MONTHLY OPERABILITY TEST EVALUATION

SUMMARY

Were all the Critical Elements performed satisfactorily? Yes No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be: Satisfactory Unsatisfactory Comments:

Evaluators Name: (Print)

Evaluators Signature: Date:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM c.docPage 10 of 11

TQ-AA-106-0303 Revision 1 INITIAL CONDITIONS

- The plant is operating at _____ power.

- The SBGT systems are lined up for standby in accordance with QCOP 7500-01.

- Radiation Protection has been notified that SBGT will be started.

- NLO stationed at 1/2B SBGT for local actions.

INITIATING CUE Perform the SBGT System Monthly Operability Test for the 1/2B train per QCOS 7500-05.

Page 11 of 11

Job Performance Measure Control Reactor Water level using RCIC JPM Number:

Date:

CR JPM d.doc Page 1 of 7

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST Delete this?

NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 and 11 below.

________ 1. Task description and number, JPM description and number are identified.

________ 2. Knowledge and Abilities (K/A) references are included.

________ 3. Performance location specified. (in-plant, control room, or simulator)

________ 4. Initial setup conditions are identified.

________ 5. Initiating and terminating cues are properly identified.

________ 6. Task standards identified and verified by SME review.

________ 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).

________ 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:

Procedure Rev. _____ Date _____________

________ 9. Pilot test the JPM:

a. verify cues both verbal and visual are free of conflict, and
b. ensure performance time is accurate.

________ 10. If the JPM cannot be performed as written with proper responses, then revise the JPM.

________ 11. When JPM is revalidated, SME or Instructor sign and date JPM cover page.

SME/Instructor Date SME/Instructor Date SME/Instructor Date Page 2 of 7

1. INITIAL CONDITIONS

- A plant transient has occurred which has resulted in the entry of QGA 100, RPV Control.

- The Reactor is scrammed and all rods have completely inserted.

- RPV level is at + 3 and stable.

- All Feedwater Pumps, HPCI, and RCIC are currently tripped due to previously receiving a Reactor Vessel Water Level - High signal.

- The Unit Supervisor requests that U1(2) RCIC be placed in service and used to restore RPV level to

+ 25 per QGA 100, RPV Level Control.

INITIATING CUE Control RPV water level IAW QCOP 1300-02 using RCIC for injection to the RPV.

Hard Cards authorized? Do not start by pushing the start button!!! OR authorize use of RCIC PB but have PB fail. (alternate path) they will then start it using manual method!!

Provide examinee with:

QCOP 1300-02 Fill in the JPM Start Time when the student acknowledges the Initiating Cue.

Information For Evaluators Use:

UNSAT requires written comments on respective step.

  • Denotes critical steps.
  • Denotes critical elements of a critical step.

Number any comments in the Comment Number column on the following pages. Then annotate that comment in the Comments section at the bottom of the page. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.

Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.

The timeclock starts when the candidate acknowledges the initiating cue.

Page 3 of 7

JPM Start Time:

Comment SAT UNSAT Number STEP ELEMENT STANDARD CUE Provide candidate with copy of QCOP 1300-02.

EVALUATOR: Candidate should recognize that QCO) 1300-02 is not immediately applicable. Trip Recovery should initially be accomplished by QCOA 1300-01.

  • D.4 Depress INITIATION SIGNAL Depresses INITIATION SIGNAL ___ ___ ___

SEAL-IN AND RESET. NO! We SEAL-IN AND RESET should let them start it by manually pushbutton.

operating these components not by simply pressing the push button!

EVALUATOR: Candidate should now enter back into procedure QCOP 1300-02.

F.4.b. Verify the turbine vacuum pump Verifies the turbine vacuum pump ___ ___ ___

has auto-started. has auto-started.

F.4.c. Verify open MO 1(2)-1301-61, Verifies MO 1(2)-1301-61 is open.

STM TO TURB VLV.

F.4.d. Verify RCIC turbine speed Verifies RCIC turbine speed is increasing. increasing.

F.4.e. Verify open MO 1(2)-1301-60, Verify that MO 1(2)-1301-60 MIN FLOW VLV. opens.

F.4.f. Verify closed AO 1(2)-1301-34 Verify that AO 1(2)-1301-34 and and 35, STM LINE DRAIN ISO 35 are closed.

VLVS.

F.4.g. Verify open MO 1(2)-1301-62, Verify that MO 1(2)-1301-62 is TURB CLG WTR VLV. open.

F.4.h Verify open MO 1(2)-1301-48, Verify that MO 1(2)-1301-48 is PMP DISCH VLV. open.

Page 4 of 7

Comment SAT UNSAT Number STEP ELEMENT STANDARD F.4.i. Verify open MO 1(2)-1301-49, Verify that MO 1(2)-1301-49 is PMP DISCH VLV. open.

F.4.j. Verify RCIC Pump discharge flow Verifies on FIC 1(2)-1340-1, PCIC increases to 400 gpm . FLOW CONTROLLER, that RCIC Pump discharge flow increases to 400 gpm.

F.4.k. Verify closed MO 1(2)-1301-60, Verify that MO 1(2)-1301-60 is ___ ___ ___

MIN FLOW VLV. closed.

  • F.4.m Adjust flow to achieve +25 inches Adjusts flow IAW step F.4.m to water level. achieve +25 inches.

EVALUATOR: Candidate should raise level in a controlled manner to achieve approximately +25 inches level.

EVALUATOR: The candidate should inform you that the task is complete.

JPM Stop Time:

VERIFY, VERIFY . Verify! We must ensure they know how to start this system using panel switches!!!! Write this up using the lower half of the hard card!

Page 5 of 7

Operators Name:

Job

Title:

NLO RO SRO STA SRO Cert Delete these, not a license position JPM

Title:

Resetting RCIC Isolation and Turbine Trip for Local Operations JPM Number:

K/A Number and Importance:

K/A: 217000 A2.02 Rating: 3.8 / 3.7 Suggested Testing Environment: Plant Actual Testing Environment: Simulator Control Room Testing Method: Simulate Alternate Path: Yes No Perform SRO Only: Yes No Time Critical: Yes No Estimated Time to Complete: 10 minutes Actual Time Used: minutes

References:

QCOP 1300-09, Rev. 17, RCIC Local Manual Operation EVALUATION

SUMMARY

Were all the Critical Elements performed satisfactorily? Yes No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be: Satisfactory Unsatisfactory Comments:

Evaluators Name: (Print)

Evaluators Signature: Date:

Page 6 of 7

INITIAL CONDITIONS

{Student Copy}

- A plant transient has occurred which has resulted in the entry of QGA 100, RPV Control.

- The Reactor is scrammed and all rods have completely inserted.

- RPV level is at + 3 and stable.

- All Feedwater Pumps, HPCI, and RCIC are currently tripped due to previously receiving a Reactor Vessel Water Level - High signal.

- The Unit Supervisor requests that U1(2) RCIC be placed in service and used to restore RPV level to

+ 25 per QGA 100, RPV Level Control.

INITIATING CUE Control RPV water level IAW QCOP 1300-02 using RCIC for injection to the RPV.

Page 7 of 7

QTI 205-S1 REVISION 1 NOVEMBER 1991 QCNPS-JOB PERFORMANCE MEASURE Operator's Name ____________________________________

(print)

THIS JPM IS IN A DIFFERENT FORMAT THAN OTHER JPMs AFTER ONSITE VALIDATION, PUT IN SAME FORMAT AS OTHER JPMs.

JPM: LS-016-II Rev: 5 Revision by: Loren Mischke Station Approval:________________________________ Date:__________

(Ops Training Group Leader)

Operations Review:_______________________________ Date:__________

Task

Title:

Bypass the Rod Worth Minimizer Task

References:

S/R-0207-TP003K/A:201006 A3.02 Rating:3.5/3.4 K/A:201006 A4.01 Rating:3.2/3.4 License: NLO/RO/SRO Suggested Testing Environment: Simulator (Circle One)

Actual Testing Environment: Simulator ___ Plant ___ CR ___

Testing Method: Simulate ____ Perform ____

Estimated Time to Complete: 8.0 min. STOP Time __________

START Time __________

Time Critical: NO __X__ YES _____ ACTUAL Time __________

References:

QCOP 207-2 Rev. 2ROD WORTH MINIMIZER BYPASS CONTROL EVALUATION

SUMMARY

1. Was the JPM completed within the maximum allotted time?

YES _____ NO _____

2. Was reasonable progress made at the maximum allotted time?

YES _____NO _____

3. Were all of the CRITICAL elements performed satisfactorily?

YES _____NO _____

The operator's performance is determined to be:

Satisfactory _____Unsatisfactory _____

COMMENTS/REMEDIATION: Procedure revision does not change the content of this JPM Evaluator's Name:_____________________________

1 of 7

QTI 205-S1 REVISION 1 NOVEMBER 1991 QCNPS-JOB PERFORMANCE MEASURE PERFORMANCE OBJECTIVE STANDARDS SAT UNSAT N/A Signature:_____________________________ Date:______

JPM SIMULATOR SETUP REQUIREMENTS JPM: LS-16-II IC#: 21 (or any other that will support this task.)

IC

Description:

The unit is operating at near rated power.

Manual Actuations:-Prepare a Caution Card IAW QOP 207-2 step F.2.a.

-Obtain a copy of OD-7, option 2 before putting in the below malfunction and overrides.

-Verify RWM blocks enabled to full.

Malfunctions:RD 19; FAILURE OF ALL RPIS INPUTS TO THE RWM (imf rd19)

Remotes: NONE Overrides:"A" and "B" RWM ready light.

(ior zlohs10207ardy off)

(ior zlohs10207brdy off) 2 of 7

QTI 205-S1 REVISION 1 NOVEMBER 1991 QCNPS-JOB PERFORMANCE MEASURE PERFORMANCE OBJECTIVE STANDARDS SAT UNSAT N/A 3 of 7

QTI 205-S1 REVISION 1 NOVEMBER 1991 QCNPS-JOB PERFORMANCE MEASURE INITIAL CONDITIONS

-Reactor power is _____ percent of rated and in the process of a normal unit shutdown.

-RWM MODE SWITCH is in NORMAL.

-RWM TRANSFER SWITCH is selected to "A", with the "A" ON LINE light lit.

-Both RWM "A READY" and "B READY" lights are extinguished.

-Annunciator 901-5-B-3, ROD WORTH MIN BLOCK is illuminated.

-This JPM is not time critical Delete this!

Initiating Cue: Bypass the Rod Worth Minimizer IAW QCOP 207-2, due to failed RPIS inputs.

START TIME _______

Provide examinee with: QCOP 207-2, now, and a copy of OD-7, option 2, when directed by cue.

Follow-up question:

Candidate's Answer:

Follow-up question:

Candidate's Answer:

Follow-up question:

Candidate's Answer:

Additional Questions/Comments:

4 of 7

QTI 205-S1 REVISION 1 NOVEMBER 1991 QCNPS-JOB PERFORMANCE MEASURE PERFORMANCE OBJECTIVE STANDARDS SAT UNSAT N/A F.1.a. Determines that Initials the blank [] []

both RWM computers provided for step are inoperable. F.1.a.

F.2.a. Prepare a Caution Asks US for [] []

Card to read, Caution Card and "RWM IN BYPASS." attaches card to Rod Movement Control Switch.

CUE:Provide the prepared Caution Card to the Examinee when requested.

  • F.2.b. Place the RWM Moves the RWM mode [] []

switch in bypass. switch to bypass.

F.2.b. Sign off step as Enters date, and [] []

complete. time in the blank provided.

F.3.(1)(a) Demands OD-7 Option Obtains printout [] []

2 from the process of OD-7 and computer. attaches to the procedure and initials step F.3.(1)(a).

EVALUATOR: Provide the operator with a copy of OD-7, Option 2.

F.3.(2) Verifies rod Compares rod [] []

pattern is positions in the correct. previous group moved 5 of 7

QTI 205-S1 REVISION 1 NOVEMBER 1991 QCNPS-JOB PERFORMANCE MEASURE PERFORMANCE OBJECTIVE STANDARDS SAT UNSAT N/A and the present group and the next group to be moved to the OD-7 printout of positions and initials step F.3.(2).

EVALUATOR: The candidate should inform you that he has completed the task.

Stop Time: ____________

6 of 7

QTI 205-S1 REVISION 1 NOVEMBER 1991 QCNPS-JOB PERFORMANCE MEASURE CANDIDATE'S COPY INITIAL CONDITIONS

-Reactor power is _____ percent of rated and in the process of a normal unit shutdown.

-RWM MODE SWITCH is in NORMAL.

-RWM TRANSFER SWITCH is selected to "A", with the "A" ON LINE light lit.

-Both RWM "A READY" and "B READY" lights are extinguished.

-Annunciators 901-5-B-3, ROD WORTH MIN BLOCK is illuminated.

-This JPM is not time critical 7 of 7

TQ-AA-106-0303 Revision 2 Exelon Nuclear Job Performance Measure Shutdown the U-1 Diesel Generator with Early Trip JPM Number: LS-035-I-F Revision Number: 05 Date: 09/06/05 Developed By:

Instructor Date Validated By:

SME or Instructor Date Review By:

Operations Representative Date Approved By:

Training Department Date CR JPM f.doc Page 1 of 10

TQ-AA-106-0303 Revision 2 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST DELETE THIS PAGE!

NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 and 11 below.

________ 1. Task description and number, JPM description and number are identified.

________ 2. Knowledge and Abilities (K/A) references are included.

________ 3. Performance location specified. (in-plant, control room, or simulator)

________ 4. Initial setup conditions are identified.

________ 5. Initiating and terminating cues are properly identified.

________ 6. Task standards identified and verified by SME review.

________ 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).

________ 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:

Procedure Rev. _____ Date _____________

________ 9. Pilot test the JPM:

a. verify cues both verbal and visual are free of conflict, and
b. ensure performance time is accurate.

________ 10. If the JPM cannot be performed as written with proper responses, then revise the JPM.

________ 11. When JPM is revalidated, SME or Instructor sign and date JPM cover page.

SME/Instructor Date SME/Instructor Date SME/Instructor Date CR JPM f.doc Page 2 of 10

TQ-AA-106-0303 Revision 2 Revision Record (Summary)

1. Revision 01, This JPM is developed IAW guidelines established in NUREG 1021 Rev 8 ES-301 and Appendix C. This JPM meets the criteria of Category B.1 "Control Room Systems," for RO/SRO candidates.
2. Revision 02, JPM revised to reflect procedure changes.
3. Revision 03, JPM revised to reflect editorial changes to Setup Instructions.
4. Revision 04, JPM revised to update expected completion time based upon JPM usage. JPM verified correct to Revision 18 of reference procedure QCOP 6600-03 Revision
18. Revision also incorporated noted pen and ink changes.
5. Revision 05, JPM revised to clarify notes and cues.

DELETE THIS PAGE!

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM f.doc Page 3 of 10

TQ-AA-106-0303 Revision 2 SIMULATOR SETUP INSTRUCTIONS

1. Reset the simulator to IC 21 (rst 21).
2. IC

Description:

100%

NOTE: It is okay to use a similar IC to the IC listed above, provided the IC actually used is verified to be compatible with this and other JPMs that are scheduled to be run concurrently.

3. Run the setup Computer Aided Exercise _____-__ (jcae! _____-__)
4. Manual Actuations:
  • Start-up, synchronize, and load the U-1 diesel generator to 1000 kw and 500 Kvars in accordance with QCOP 6600-02 F.2.c-j.
5. Malfunctions:

a) Override annunciators OFF

  • imf ano9018a7 off
  • imf ano9018g8 off b) Set Triggers 11, 12, and 14 to automatically trip the diesel 30 seconds after the C/S is taken to stop and then delete the trip malfunction when the C/S is taken back to start
  • trgset 11 .not.an:9018b7
  • trg 11 imf dg01a (none 30)
  • trgset 12 zdihs16600strt(1).and..not.an:9018b7
  • trg 12 dmf dg01a
  • trgset 13 zdihs16600strt(1).and..not.an.9018b7
  • trg 13 mrf dg03r reset
  • trgset 14 .not.an:9018b7
  • trg 14 imf ano9018b7 off
6. Remotes:
  • Set the U-1 Diesel Speed Droop to 50. (mrf dg01r 1)
  • After the Diesel is running, reset the local DG annunciator panel. (mrf dg18r 1)

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM f.doc Page 4 of 10

TQ-AA-106-0303 Revision 2

  • Set the speed droop to "0" when requested by the evaluator, after the operator opens the output breaker. (mrf dg01r 0)
7. Overrides: NONE
8. When the above steps are completed for this and other JPMs to be run concurrently, then validate the concurrently run JPMs using the JPM Validation Checklist.
9. This completes the setup for this JPM.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM f.doc Page 5 of 10

TQ-AA-106-0303 Revision 2 INITIAL CONDITIONS

- You are the U1 Assist NSO.

- Transformer 12 had been taken Out-of-Service for Substation Construction.

- The Unit and 1/2 Diesel generators had been supplying their emergency busses.

- Transformer 12 has just been repaired, returned to service, and energized, supplying busses 12 and 13.

- The 1/2 diesel has been shutdown and bus 13-1 is now being supplied with its normal feed, bus 13.

- Bus 14-1 is now energized from its normal power supply however the U-1 diesel is still running in parallel with the grid.

- The Shift Manager has authorized taking the U-1 diesel off.

- The NLO has set the Speed Droop to 50.

- This JPM is not time critical. DELETE THIS STATEMENT!

INITIATING CUE Unload and shut down the U1 EDG per QCOP 6600-03. Notify the Unit Supervisor at the completion of the cooldown.

Fill in the JPM Start Time when the student acknowledges the Initiating Cue.

Information For Evaluators Use:

UNSAT requires written comments on respective step.

  • Denotes critical steps.
  • Denotes critical elements of a critical step.

Number any comments in the Comment Number column on the following pages. Then annotate that comment in the Comments section at the bottom of the page. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.

Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.

The timeclock starts when the candidate acknowledges the initiating cue.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM f.doc Page 6 of 10

TQ-AA-106-0303 Revision 2 JPM Start Time:

Comment SAT UNSAT Number STEP ELEMENT STANDARD Obtain procedure to be used. Obtains copy of QCOP 6600-03. ___ ___ ___

EVALUATOR: Maintaining VARS 1/2 the KW is NOT critical.

F.4.a. Reduce DG load to zero KW while Positions governor to decrease ___ ___ ___

maintaining VARS approx. one- until KW meter is 0. Stops when half the KW value. KW = 0. Positions volt. reg. To decrease while maintaining VARS one-half of KW.

Positions Diesel 1 to 4 KV Bus

  • F.4.b. *Open DG output breaker.* ___ ___ ___

14-1 brk.

CS to Trip when DG is unloaded.

- Open light lit.

  • F.5. *Set speed droop to 0. Directs NLO to Set SPEED ___ ___ ___

DROOP to 0.

EVALUATOR: Request the simulator operator to set the speed drop to 0 using remote function dg01r (mrf dg01r 0).

CUE: The speed droop has been set to 0.

  • F.6.a. *Adjust DG Frequency to 60 hertz Ensures DG set at 60 hz. ___ ___ ___

with Governor switch.*

  • F.6.b. *Adjust DG voltage between 4100 Ensures DG voltage is as close to to 4200 volts, but as close to 4160 4160 as possible.

as possible with voltage regulator (VARS switch).*

F.7. Have independent verification of ___ ___ ___

settings.

CUE: I agree with the voltage and frequency settings.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM f.doc Page 7 of 10

TQ-AA-106-0303 Revision 2 Comment SAT UNSAT Number STEP ELEMENT STANDARD

  • F.8. *Stops Diesel Gen.* Positions engine CS to STOP for 2- ___ ___ ___

3 seconds at Panel 901-8.

  • F.9. *Return Diesel Control Switch to Positions CS for U1 DG to AUTO.

AUTO.*

  • F.10. *Monitors DG cooldown.* Recognize DG cooldown cycle ___ ___ ___

incomplete due to DG early shutdown.

  • F.10.a. *Restart DG.* Place DG engine CS switch to ___ ___ ___

START.

  • F.10.b. *Place DG C/S in OFF.* Positions engine CS to STOP for 2- ___ ___ ___

3 seconds at Panel 901-8.

  • F.10.c. *Return DG switch to AUTO.* Positions CS for U1 DG to AUTO.

F.11. Verify DG runs for 8-11 minutes Allow cooldown time for DG.

total for cooldown.

TIME COMPRESSION MAY BE USED FOR COOLDOWN PERIOD.

CUE: The diesel has to run for 11 minutes and is now off.

EVALUATOR: The candidate should inform you that the task is complete.

JPM Stop Time:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM f.doc Page 8 of 10

TQ-AA-106-0303 Revision 2 Operators Name:

Job

Title:

NLO RO SRO STA SRO Cert Delete these!

JPM

Title:

Shutdown the U-1 Diesel Generator with Early Trip JPM Number: LS-035-I-F Revision Number: 05 Task Number and

Title:

SR-6600-P03 (Freq: LIC=I) Given an operating reactor plant with an emergency DG carrying an emergency bus with normal power restored, transfer the bus to its normal supply and shutdown the DG in accordance with QCOP 6600-03.

K/A Number and Importance:

K/A: 264000 A4.04 Rating: 3.7/3.7 Suggested Testing Environment: Simulator Actual Testing Environment: Simulator Control Room In-Plant Testing Method: Simulate Alternate Path: Yes No Perform SRO Only: Yes No Time Critical: Yes No Estimated Time to Complete: 17 minutes Actual Time Used: minutes

References:

QCOP 6600-03, Rev. 18, DIESEL GENERATOR 1(2) SHUTDOWN EVALUATION

SUMMARY

Were all the Critical Elements performed satisfactorily? Yes No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be: Satisfactory Unsatisfactory Comments:

Evaluators Name: (Print)

Evaluators Signature: Date:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM f.doc Page 9 of 10

INITIAL CONDITIONS

{Student Copy}

- You are the U1 Assist NSO.

- Transformer 12 had been taken Out-of-Service for Substation Construction.

- The Unit and 1/2 Diesel generators had been supplying their emergency busses.

- Transformer 12 has just been repaired, returned to service, and energized, supplying busses 12 and 13.

- The 1/2 diesel has been shutdown and bus 13-1 is now being supplied with its normal feed, bus 13.

- Bus 14-1 is now energized from its normal power supply however the U-1 diesel is still running in parallel with the grid.

- The Shift Manager has authorized taking the U-1 diesel off.

- The NLO has set the Speed Droop to 50.

- This JPM is not time critical. Delete this statement.

INITIATING CUE Unload and shut down the U1 EDG per QCOP 6600-03. Notify the Unit Supervisor at the completion of the cooldown.

Page 10 of 10

TQ-AA-106-0303 Revision 2 Exelon Nuclear Job Performance Measure Change-Over Reactor Feed Pumps With Failure Of Auxiliary Oil Pump To Trip JPM Number: LS-024-I-F Revision Number: 06 Date: 09/06/05 Developed By:

Instructor Date Validated By:

SME or Instructor Date Review By:

Operations Representative Date Approved By:

Training Department Date CR JPM g.doc Page 1 of 10

TQ-AA-106-0303 Revision 2 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST DELETE THIS PAGE!

NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 and 11 below.

________ 1. Task description and number, JPM description and number are identified.

________ 2. Knowledge and Abilities (K/A) references are included.

________ 3. Performance location specified. (in-plant, control room, or simulator)

________ 4. Initial setup conditions are identified.

________ 5. Initiating and terminating cues are properly identified.

________ 6. Task standards identified and verified by SME review.

________ 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).

________ 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:

Procedure Rev. _____ Date _____________

________ 9. Pilot test the JPM:

a. verify cues both verbal and visual are free of conflict, and
b. ensure performance time is accurate.

________ 10. If the JPM cannot be performed as written with proper responses, then revise the JPM.

________ 11. When JPM is revalidated, SME or Instructor sign and date JPM cover page.

SME/Instructor Date SME/Instructor Date SME/Instructor Date CR JPM g.doc Page 2 of 10

TQ-AA-106-0303 Revision 2 Revision Record (Summary)

1. Revision 01, This JPM is developed IAW guidelines established in NUREG 1021 Rev 8 ES-301 and Appendix C. This JPM meets the criteria of Category B.1 "Control Room Systems," for RO/SRO candidates.
2. Revision 02, JPM revised to match procedure changes.
3. Revision 03, JPM revised to match procedure changes and update estimated time.
4. Revision 04, JPM revised to reflect procedure and format changes.
5. Revision 05, JPM revised to match procedure changes and update estimated time.
6. Revision 06, JPM revised to match procedure changes.

DELETE THIS PAGE!

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM g.doc Page 3 of 10

TQ-AA-106-0303 Revision 2 SIMULATOR SETUP INSTRUCTIONS

1. Reset the simulator to IC 20 (rst 20 ).

NOTE: It is okay to use a similar IC to the IC listed above, provided the IC actually used is verified to be compatible with this and other JPMs that are scheduled to be run concurrently.

2. Run the setup Computer Aided Exercise _____-__ (jcae! _____-__)
3. Manual Actuations:
  • Ensure the A and B RFPs are on.
  • Ensure Zinc Injection magnet placed near 1B RFP switch.
  • Ensure the A, B, and C cond/cond booster pumps are on.
  • Insert override to fail the aux oil pump to trip when 1C RFP is started.

ior lohs13201aopc3 on ior lohs13201aopc1 off ior lohs13201aopc2 off

  • Override alarm 901-6 F7 off (imf ano9016f7 off)
4. Malfunctions: NONE
5. Remotes: NONE
6. Overrides: NONE
7. When the above steps are completed for this and other JPMs to be run concurrently, then validate the concurrently run JPMs using the JPM Validation Checklist.
8. This completes the setup for this JPM.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM g.doc Page 4 of 10

TQ-AA-106-0303 Revision 2 INITIAL CONDITIONS Unit 1 is operating at approximately ___ MWe.

- The 1A Reactor Feed Pump seal has been leaking and getting steadily worse.

- The Shift Manager has ordered that the 1A RFP be taken off and the 1C RFP started.

- Zinc injection is lined up to 1B RFP.

- The 1D Condensate Pump has NOT been isolated.

- An NLO has been briefed and dispatched to check out the standby Condensate pump for start per step F.3.d of QOP 3200-04.

- 1C RFP has been filled and vented IAW QCOP 3200-01.

- This is NOT a time critical JPM. Delete this!

INITIATING CUE Place the 1C RFP in service, powered from Bus 11, and place the 1A RFP in pull-to-lock in preparation for taking it out-of-service.

Fill in the JPM Start Time when the student acknowledges the Initiating Cue.

Information For Evaluators Use:

UNSAT requires written comments on respective step.

  • Denotes critical steps.
  • Denotes critical elements of a critical step.

Number any comments in the Comment Number column on the following pages. Then annotate that comment in the Comments section at the bottom of the page. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.

Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.

The timeclock starts when the candidate acknowledges the initiating cue.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM g.doc Page 5 of 10

TQ-AA-106-0303 Revision 2 JPM Start Time:

Comment SAT UNSAT Number STEP ELEMENT STANDARD Obtain procedure to be used. Obtains copy of QOP 3200-4. ___ ___ ___

F.1. Determine if zinc injection aligned Verifies zinc injection not valved ___ ___ ___

to RFP to be shutdown then valve to 1A RFP.

out zinc injection.

F.2. Verifies condensate pump to be Verifies from initial conditions that ___ ___ ___

started is not isolated. 1D condensate pump is not isolated.

CUE: If asked, NLO reports 1D cond. pp. ready for start, F.3.d. and F.4 of QOP 3200-04 is completed.

CUE: If asked, 1D cond/cond booster is NOT being started for the first time after maintenance.

F.5. Verifies condensate pump to be Verifies from initial conditions that ___ ___ ___

started is not isolated. 1D condensate pump is not isolated.

F.6. Place the cond. pmp. selector Positions COND PMP ___ ___ ___

switch to OFF. SELECTOR switch to OFF, standby light goes out.

  • F.7. *Start standby condensate pump.* Positions 1D COND PMP CS to ___ ___ ___

close -

On light lit -

Motor amps increase then stabilize.

F.8.a. Verify cond. pp. disch. press. Verifies cond. pp. disch. press. > ___ ___ ___

140 psig.

F.8.b. Verify booster pp. suc. press. Verifies booster pp. suc. press. >

110 psig.

F.8.c. Verify booster pp. disch. press. Verifies booster pp. disch. press. > ___ ___ ___

220 psig.

F.8.d. Verify RFP suc. press. Verifies RFP suc. press. > 200 psig.

CUE: The NLO reports 1D cond. pp. post-start checks are sat and is enroute to the RFP room.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM g.doc Page 6 of 10

TQ-AA-106-0303 Revision 2 Comment SAT UNSAT Number STEP ELEMENT STANDARD F.10.a. For RFP to be S/D, verify auxiliary Verifies red target and yellow auto ___ ___ ___

b. oil pump control switch has red trip light lit for 1A RFP.

target and yellow auto trip light lit.

F.11. De-select standby RFP. Positions RFP SELECTOR switch ___ ___ ___

to off-1C RFP standby light out.

Instructor Note: Candidate may order QOP 3200-04 Steps F.14 completed. If so, acknowledge QOP 3200-04 step F.14 is complete.

F.14.a. Verify 1C RFP min-flow valve at Verifies with US ___ ___ ___

condenser 1-3213C, locked open OR by checking passport, procedure in progress book and equipment status tags.

CUE: 1C RFP min-flow valve is locked open.

F.14b. Verify open RFP suc vlv Directs operator to verify 1C RFP ___ ___ ___

1-3499-17. suc. vlv. 1-3499-17 Open.

CUE: 1C RFP suc vlv 1-3499-17 is open.

F.14.c. Vent pp. casing. Directs operator to vent 1C RFP ___ ___ ___

(1-4) casing.

CUE: The pp. casing is vented, steps F.14.c.(1)-(4) are complete.

F.14.d. Verify TBCCW lined-up to 1C Directs operator to verify TBCCW ___ ___ ___

-m. RFP. lined-up to 1C RFP:

- Oil Cooler

- Seal Cooler

- Seal Jacket Cooler CUE: TBCCW lined-up to all 1C RFP components, steps F.14.(d)-(m) are complete.

F.14.n. Verify normal oil level. Directs operator to verify 1C RFP ___ ___ ___

oil reservoir at normal level.

CUE: The 1C RFP oil reservoir normal F.14.o. Verify 1C RFP auxiliary oil pump Verifies red target and red on light ___ ___ ___

is operating. lit for 1C RFP auxiliary oil pump.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM g.doc Page 7 of 10

TQ-AA-106-0303 Revision 2 Comment SAT UNSAT Number STEP ELEMENT STANDARD F.14.p. Determines that 1C RFP bearing Directs operator to verify 1C RFP ___ ___ ___

(1-4) lube oil pressure adjustment is not bearing lube oil pressure between necessary. 11 to 13 psig.

CUE: The NLO reports 1C RFP bearing lube oil pressure is 12 psig.

F.20.a. Close RFP "C" Disch Vlv. Positions C/S for MO 1-3201C to ___ ___ ___

close. Verifies green light lit.

F.20.b. Open RFP C Min Flow Vlv. Positions C/S for AO 1-3201-C to ___ ___ ___

open. Verifies red light lit.

  • F.21. *Start 1C RFP.* Positions 1C RFP Bus 11 CS to ___ ___ ___

close.

- On light lit-motor amps.

  • F.22. *If Aux oil pump fails to auto trip, Trip 1C RFP and reports problem ___ ___ ___

then trip RFP.* to the US.

EVALUATOR: Acknowledge the report of the 1C RFP Aux Oil Pump and state, another NSO will secure the 1D condensate pump. The candidate should inform you that the task is complete.

JPM Stop Time:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM g.doc Page 8 of 10

TQ-AA-106-0303 Revision 2 Operators Name:

Job

Title:

NLO RO SRO STA SRO Cert Delete This JPM

Title:

Change-Over Reactor Feed Pumps With Failure Of Auxiliary Oil Pump To Trip JPM Number: LS-024-I-F Revision Number: 06 Task Number and

Title:

SR-3200-P02 (Freq: LIC=I) Given a reactor plant during a startup, start the first reactor feed pump in accordance with QOP 3200-02.

K/A Number and Importance:

K/A: 259001.A4.02 Rating: 3.9/3.7 Suggested Testing Environment: Simulator Actual Testing Environment: Simulator Control Room In-Plant Testing Method: Simulate Alternate Path: Yes No Perform SRO Only: Yes No HOW IS THIS AN ALTERNATE PATH JPM????

Time Critical: Yes No Estimated Time to Complete: 18 minutes Actual Time Used: minutes

References:

QOP 3200-04, Rev. 32 REACTOR FEED PUMP CHANGE OVER EVALUATION

SUMMARY

Were all the Critical Elements performed satisfactorily? Yes No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be: Satisfactory Unsatisfactory Comments:

Evaluators Name: (Print)

Evaluators Signature: Date:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM g.doc Page 9 of 10

INITIAL CONDITIONS Unit 1 is operating at approximately ___ MWe.

- The 1A Reactor Feed Pump seal has been leaking and getting steadily worse.

- The Shift Manager has ordered that the 1A RFP be taken off and the 1C RFP started.

- Zinc injection is lined up to 1B RFP.

- The 1D Condensate Pump has NOT been isolated.

- An NLO has been briefed and dispatched to check out the standby Condensate pump for start per step F.3.d of QOP 3200-04.

- 1C RFP has been filled and vented IAW QCOP 3200-01.

- This is NOT a time critical JPM. Delete this!

INITIATING CUE Place the 1C RFP in service, powered from Bus 11, and place the 1A RFP in pull-to-lock in preparation for taking it out-of-service.

Page 10 of 10

Job Performance Measure Transfer Recirculation Flow Control from Manual to Master JPM Number:

Revision Number:

Date:

Developed By:

Instructor Date Validated By:

SME or Instructor Date Review By:

Operations Representative Date Approved By:

Training Department Date CR JPM h.doc Page 1 of 7

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST DELETE THIS PAGE!!!

NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 and 11 below.

________ 1. Task description and number, JPM description and number are identified.

________ 2. Knowledge and Abilities (K/A) references are included.

________ 3. Performance location specified. (in-plant, control room, or simulator)

________ 4. Initial setup conditions are identified.

________ 5. Initiating and terminating cues are properly identified.

________ 6. Task standards identified and verified by SME review.

________ 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).

________ 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:

Procedure Rev. _____ Date _____________

________ 9. Pilot test the JPM:

a. verify cues both verbal and visual are free of conflict, and
b. ensure performance time is accurate.

________ 10. If the JPM cannot be performed as written with proper responses, then revise the JPM.

________ 11. When JPM is revalidated, SME or Instructor sign and date JPM cover page.

SME/Instructor Date SME/Instructor Date SME/Instructor Date CR JPM h.doc Page 2 of 7

INITIAL CONDITIONS

- You are an extra NSO on shift.

- Unit 1(2) is operating at 70% power.

- Problems occurred earlier in the shift that resulted in the 1(2) A MG Set failing such that its speed could not be controlled from the Control Room.

- An operator was dispatched at that time to Lock Up the MG Set Scoop Tube. The problem has been resolved and the recirculation system is ready to be operated in the MASTER mode.

- Recirc pump speeds are matched with the 1(2) A recirc pump in individual manual control.

- This JPM is not time critical. DELETET THIS!

INITIATING CUE Transfer the 1(2) A Recirc MG Set from MANUAL to AUTOMATIC control and then raise flow to 70%.

Fill in the JPM Start Time when the student acknowledges the Initiating Cue.

Information For Evaluators Use:

UNSAT requires written comments on respective step.

  • Denotes critical steps.
  • Denotes critical elements of a critical step.

Number any comments in the Comment Number column on the following pages. Then annotate that comment in the Comments section at the bottom of the page. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.

Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.

The timeclock starts when the candidate acknowledges the initiating cue.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM h.doc Page 3 of 7

JPM Start Time:

Comment SAT UNSAT Number STEP ELEMENT STANDARD Obtains procedure to be used. Gets copy of QCOP 0202-03. ___ ___ ___

CUE Provide candidate with QCOP 0202-03 after candidate has selected QCOP 0202-03.

F.4.a. Verify FW flow is > 3.0 FW flow verified as >3.0 Mlb/hr. ___ ___ ___

Mlb/hr.

  • F.4.b. Depress MASTER pushbutton Depresses MASTER pushbutton ___ ___ ___

on 1(2) -0262-25A/B, LOOP on 1(2) -0262-25A/B, LOOP A/B A/B SPEED CONTROLLER. SPEED CONTROLLER.

F.4.b.(1) Verify MASTER pushbutton is Checks that MASTER pushbutton ___ ___ ___

lit at both LOOP A/B SPEED is lit at both LOOP A/B SPEED CONTROLLERs. CONTROLLERs.

  • F.3. Depress the RAISE pushbutton Depresses the RAISE pushbutton ___ ___ ___

on 1(2)-0262-22, MASTER on 1(2)-0262-22, MASTER SPEED DEMAND, to raise the SPEED DEMAND, and raises the speed of both pumps to 70%. speed of both pumps to 70%.

CUE EVALUATOR: Pushbutton ___ ___ ___

1(2)-0262-22, MASTER SPEED DEMAND, is stuck in the RAISE position and flow continues to rise.

  • F.5 Depress MANUAL pushbutton Recognizes that, as per Precaution ___ ___ ___

on 1(2) -0262-25A/B, LOOP D.3, this condition requires the A/B SPEED CONTROLLER. controller to be transferred back to MANUAL mode. Transfers back to MANUAL mode.

  • F.5.a. Verify MANUAL pushbutton Verifies pushbutton is lit. ___ ___ ___

is lit at both LOOP A/B SPEED CONTROLLERs.

  • D.2 and Depress LOWER pushbutton Depresses LOWER pushbutton to ___ ___ ___

F.2 on LOOP A/B SPEED stop stuck control input CONTROLLER. (pushbutton in RAISE). Notifies Control Room Supervisor that flow is no longer increasing.

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM h.doc Page 4 of 7

Comment SAT UNSAT Number STEP ELEMENT STANDARD CUE Once the LOWER pushbutton is depressed, the flow will stop rising.

JPM Stop Time:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM h.doc Page 5 of 7

Operators Name:

Job

Title:

NLO RO SRO STA SRO Cert Delete this JPM

Title:

Transfer Recirculation Flow Control from Manual to Master JPM Number: Revision Number:

Task Number and

Title:

SR-0202-P08 (Freq: LIC=I) Given an operating reactor plant and a loss of speed control of a reactor recirculation pump, take local manual control and adjust recirc pump speed in accordance with QCOP 0202-12.

K/A Number and Importance:

K/A: 202002.2.1.30 Rating: 3.9/3.4 Suggested Testing Environment: Plant Actual Testing Environment: Simulator Control Room n In-Plant Testing Method: n Simulate Alternate Path: Yes??? n No Perform SRO Only: Yes n No IS THIS JPM ALTERNATE PATH????

Time Critical: Yes n No Estimated Time to Complete: 10 minutes Actual Time Used: minutes

References:

QCOP 0202-03, REV 17, REACTOR RECIRCULATION SYSTEM FLOW CONTROLLER OPERATION EVALUATION

SUMMARY

Were all the Critical Elements performed satisfactorily? Yes No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be: Satisfactory Unsatisfactory Comments:

Evaluators Name: (Print)

Evaluators Signature: Date:

G:\License Examinations\2007\2007 Quad Cities Exam\Proposed Exam\JPMs\CR JPM h.doc Page 6 of 7

INITIAL CONDITIONS

- You are an extra NSO on shift.

- Unit 1(2) is operating at 70% power.

- Problems occurred earlier in the shift that resulted in the 1(2) A MG Set failing such that its speed could not be controlled from the Control Room.

- An operator was dispatched at that time to Lock Up the MG Set Scoop Tube. The problem has been resolved and the recirculation system is ready to be operated in the MASTER mode.

- Recirc pump speeds are matched with the 1(2) B recirc pump in individual manual control.

- This JPM is not time critical. Delete this!

INITIATING CUE Transfer the 1(2) A Recirc MG Set from MANUAL to AUTOMATIC control and then raise flow to 70%.

Page 7 of 7