ES-401 Record of Rejected K/As Form ES-401-4 Tier /
Group Randomly Selected K/A Reason for Rejection RO T1-G1 Q-(3) 239001 G2.4.20 239001 G2.4.49 K/A rejected due to no warnings, cautions, and notes of partial or total loss of DC power in the EOPs K/A 295004 G.2.4.49 randomly selected as replacement by the Chief Examiner.
RO T1-Gr1 Q-17 295026 EK2.10 295037 EK2.03 K/A rejected due to inability to write an operationally valid exam item to the K/A statement. K/A 295026 EK2.03 randomly selected as replacement by the Chief Examiner.
SRO T1-Gr1 Q-82 700000 G2.1.25 700000 G2.1.32 K/A rejected due to inability to write an operationally valid exam item to the K/A statement. K/A 700000 G2.1.32 randomly selected as replacement by the Chief Examiner.
SRO T2-Gr2 Q-91 234000 A1.01 234000 A1.03 K/A rejected due to having another closely related K/A in the exam. K/A 234000 A1.03 randomly selected as replacement by the Chief Examiner.
SRO T2-Gr2 Q-92 268000 A2.01 268000 G2.2.38.
K/A due to inability to write an operationally valid, SRO level exam item to the K/A statement. K/A 268000 G2.2.38 randomly selected as replacement by the Chief Examiner.
SRO T2-Gr2 Q-93 271000 G2.2.38 271000 A2.04 K/A rejected by NRC due to requiring even distribution of K/A types. K/A 271000 A2.04 randomly selected as replacement by the Chief Examiner.