James Davis - LRA B.1.1, Boraflex Program
-Pag e-- 1 -1 James Davis-LRA B.1.1 Boraflex Pogram Pa*e I
From:
<erachp@comcast.net>
To:
Peter Wen <pxw@nrc.gov>
Date:
08/14/2006 9:53:58 PM
Subject:
LRA B.1.1, Boraflex Program
- Peter, While reviewing the draft audit and review report, the following needs closure:
Section 3.0.3.1.1.2 - Second paragraph has a future action. You state:
During the audit and review, the project team noted that the applicant's LRPD-02, Section 4.1 did not distinguish the Boron-10 Areal Density Gage for Evaluating Racks (BADGER) test from the blackness testing. The project team asked the applicant to clarify that the BADGER test used in PNPS is an areal density measurement. The applicant responded that its LRPD-02, Sections 4.1.B.2b and 4.1.B.4b will be revised to clarify that BADGER test is an areal density measurement.
Did you verify during the second site visit that LRPD-02 was revised? If so, I need a positive statement to close out this item. As written, it is an open item.
Please give me the appropriate words.
Erach CC:
Jim Davis <jad@nrc.gov>
cAtemp\\GWJ00001.TMP Page 1 1
-epGWOOO TM-ag-I Mail Envelope Properties (44E12928.42B :24 :54315)
Subject:
LRA B.1.1, Boraflex Program Creation Date 08/14/2006 9:53:17 PM From:
<erachp@comcast.net>
Created By:
erachp@comcast.net Recipients nrc.gov TWGWPOO4.HQGWDOO1 PXW (Peter Wen) nrc.gov OWGWPO03.HQGWDO01 JAD CC (James Davis)
Post Office Route TWGWPOO4.HQGWDOO1 nrc.gov OWGWPOO3.HQGWDO01 nrc.gov Files Size Date & Time MESSAGE 846 08/14/2006 9:53:17 PM TEXT.htm 1220 Mime.822 3557 Options Expiration Date:
None Priority:
Standard ReplyRequested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled
c:\\temp\\GW}00001.TMP Page 21]
Block List is not enabled